HomeMy WebLinkAbout421 S Huron Dr - PlanSolar Module Details
Module Type Q-Cell
Module Quantity 14
Module Model Number 400 watt
Design Criteria
Code: 2022 California Building Code ASCE 7-16
Live Load (psf)20
Ult Wind Speed (mph)110
Exposure Cat C
Ground Snow (psf)20
Structure Geometry
Eave Height, he (ft)15 to 20ft
Pitch of main roof (deg)23
Building Length, L (ft)60
Building Width, B (ft)50
Roof Area (Module Area) ft2 3000.00
Standoff(i.e., Roof Mount) Spacing Feet 6`
Roof Properties
Roof Geometry type Mono Slope Roof
Roof Type Single Span Rafter
Roof Pitch (deg)23
303 N. Glenoaks Blvd Suite #200 Burbank, CA 91502 | (747)333-5991 | new@engineerinc.io
421 S Huron Dr -
2018016207/03/23
Roofing Type Comp Shingles
Sheathing Type 1/2" OSB Board
Wood species No. 2, Douglas Fir-Larch
Wood Fb (psf)900
Wood Fv (psf)180
Wood E (psf)1600000
Purlin C/C Spacing (in)12
Rafter C/C. Spacing (in.)24
Purlin
Section Thickness, b (in.)2
Section Depth, d (in.)4
Rafter
Section Thickness, b (in.)2
Section Depth, d (in.)6
Maximum Rafter Span (ft)11
Factors
Cd(wind)1.60
Cd(Snow)1.60
CLS 1.15
CM 1
Ct 1
CL 0.75
CF 1.5
Cfu 1
Cv 1
Cr 1
M allowable_wind 1020.94
M allowable_snow 733.80
303 N. Glenoaks Blvd Suite #200 Burbank, CA 91502 | (747)333-5991 | new@engineerinc.io
421 S Huron Dr -
2018016207/03/23
Dead Load(psf)
Comp Shingles 3.00 psf
1/2" OSB Board 2.00 psf
Insulation 2.00 psf
Total Roof 1DL 7 psf
No. 2, Douglas Fir-Larch 31.00 lb/ft3
Solar Panel DL 3.00 psf
Roof 1
Roof_Dist_DL 7.00 psf
M_Roof_Dist_DL 6171.30
Def_Roof_Dist_DL 2.34
PV_uni_Dist_DL 3.00 psf
M_PV_uni_Dist_DL 39.02
Def_PV_uni_Dist_DL 0.01
Total_Uni_DL 11.00 psf
M_Total_DL 6210.32
Def_Total_DL 2.35
Snow Load(psf)
Ground Snow Load, pg 20
Importance Factor, Ic 1
Thermal Factor, Ct 1
Exposure Factor, Ce 1
Flat roof snow, pF 20
Slope Factor, Cs 1
303 N. Glenoaks Blvd Suite #200 Burbank, CA 91502 | (747)333-5991 | new@engineerinc.io
421 S Huron Dr -
2018016207/03/23
Sloped Row Snow, ps 20
Uni_Dist_S 20.00
M_uni_Dist_s 302.50
Def_uni_Dist_S 0.11
Wind Load
Ultimate Wind Speed 110
Directionality Factor,kd 0.85
Topographic factor 1.00
Velocity pressure exposure factor,kz 0.88
Ground Elevation Factor,ke 0.95
Side Wall Width 50
Median Roof Height 57.20
Velocity pressure,qz 23.17
External Pressure Up,GCp_1 -0.546
External Pressure Up,GCp_2 -0.6
External Pressure Up,GCp_3 -1.26
External Pressure Down,GCp -0.0388
Design Pressure Up,p_1 -10.58
Design Pressure Up,p_2 -11.62
Design Pressure Up,p_3 -24.41
Design Pressure Up,p -0.75
Uni_Dist_W_up -24.41
M_uni_Dist_W_up -369.20
Def_uni_Dist_W_up -0.14
Uni_Dist_W_down -0.75
303 N. Glenoaks Blvd Suite #200 Burbank, CA 91502 | (747)333-5991 | new@engineerinc.io
421 S Huron Dr -
2018016207/03/23
M_uni_Dist_W_down -11.34
Def_uni_Dist_W_down -0.00
Lag Screw Uplift Check (ASD)
5/16" Lag Screw Withdrawl value 205.00 lb/in
Lag Screw Penetration 2.50 in
Roof1 0.6D+0.6W(up z1)2686.584 > 512.5
Roof1 0.6D+0.6W(up z2)2685.96 > 512.5
Framing Check (ASD):
Roof1 uni 1.0D+0.6W 6210.32 > 1020.94
Lag Screw Penetration 6437.20 > 1020.94
Roof1 0.6D+0.6W(up z1)6512.82 > 733.80
Roof1 0.6D+0.6W(up z2)3504.67 > 1020.94
Seismic Check:
Wood 5.00 psf
2x4 Studs @ 16"2.00 psf
Gypsum 3.00 psf
Misc(insulatioon,etc)2.00 psf
Total wall DL 12.00 psf
Total Wall Area (Approx)2590.00 ft2
Total Wall W 31080 lbs
Total Roof DL 7.50 psf
Total Roof Area (Approx)1303.52 ft2
Total Roof W 9776.4 lbs
303 N. Glenoaks Blvd Suite #200 Burbank, CA 91502 | (747)333-5991 | new@engineerinc.io
421 S Huron Dr -
2018016207/03/23
OK
PV Panel W 3.00 psf
Area of panel 280.00 ft2
Total Roof W 410.61 lbs
% increase=(Wadditional)/Wexisting 1.07%
The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further
seismic analysis is required.
Limits of Scope of Work and Liability
Existing structure is assumed to have been designed and constructed following appropriate codes at
time of erection, and assumed to have appropriate permits. The calculations produced are only for the
roof framing supporting the proposed PV installation referenced in the stamped planset and were
completed according to generally recognized structural analysis standards and procedures, professional
engineering and design experience, opinions and judgements. Existing deficiencies which are unknown
or were not observable during time of inspection are not included in this scope of work. All PV modules,
racking, and mounting equipment shall be designed and installed per manufacturer's approved
installation specifications. The Engineer of Record and Engineerinc assume no responsibility for misuse
or improper installation. This analysis is not stamped for water leakage. Framing was determined based
on information in provided plans and/or photos, along with engineering judgement. Prior to
commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the
stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any
discrepancies prior to starting construction. Contractor shall also verify that there is no damaged framing
that was not addressed in stamped plans, calculations, and cert letter (where applicable) and notify the
Engineer of Record of any concerns prior to starting construction. Prior to the commencement of work,
the contractor shall verify the existing roof and framing conditions. Notify Engineerinc and the engineer of
record of any Discrepancies prior to starting construction. Prior to the commencement of work, the
contractor shall inspect framing for any damage such as water damage, cracked framing, etc. and notify
the E.O.R. if any issues are found.These plans/calculations are stamped for structural code compliance
of the roof framing supporting the proposed PV installation reference only. These plans/calculations are
not stamped for water leakage. PV modules, racking, and attachment components must follow
manufacturer guidelines and requirements.
303 N. Glenoaks Blvd Suite #200 Burbank, CA 91502 | (747)333-5991 | new@engineerinc.io
421 S Huron Dr -
2018016207/03/23
Date: 06/01/2023
Job Number: 14230
Prepared for : Eco Force Electric Inc., 17415 Villa Corta St, La Puente, CA 91744
Project.: Gregorio Corona , 421 S Huron Dr, , Santa Ana, CA, 92704,
The following calculations are for the structural engineering design of the photovoltaic panels and are
valid only for the structural info referenced in the stamped plan set. The verification of such info is the
responsibility of others. After review, I certify that the roof structure has sufficient structural capacity for
the applied PV loads. All PV mounting equipment shall be designed and installed per manufacturer's
approved installation specifications.
Engineerinc.io
303 N Glenoaks Blvd Suite 200
Burbank, CA 91502
(747) 333 - 5991
new@engineerinc.io
303 N. Glenoaks Blvd Suite #200 Burbank, CA 91502 | (747)333-5991 | new@engineerinc.io
421 S Huron Dr -
2018016207/03/23
Structural Engineering Letter
Date: 06/01/2023
Project Name: Gregorio Corona
Project Address: 421 S Huron Dr, , Santa Ana, CA, 92704,
Contractor : Eco Force Electric Inc.
Contractor Address : 17415 Villa Corta St, La Puente, CA 91744
Attn : To Whom It May Concern
A Field observation of the condition of the existing framing system was performed by an audit team from
Eco Force Electric Inc.. From the Field observation of the property, the existing roof structure observed
as follows:
Existing roof is supported by 2 x 6 @ 24" rafters at the solar array. The rafters are sloped at
approximately 23 degree and have maximum projected horizontal span of 11 feet in between
load bearing supports.
Design Criteria
Applicable codes: 2022 California Building Code ASCE
7-16
Ground Snow Load: 20 psf
Roof Dead Load: 20 psf
Wind speed: 110 mph
Risk Category: II
I certify that the capacity of the structural roof framing that directly supports the additional gravity loading
due to the solar panel supports and modules had been reviewed and determined to meet or exceed the
requirements in accordance with the Design Criteria.
If you have any questions or concerns please contact us,
Engineerinc.io,
303 N Glenoaks Blvd Suite 200
Burbank, CA 91502
(747) 333 - 5991
new@engineerinc.io
Digitally
signed by
Manouchehr
Hakhamaneshi
Date:
2023.06.01
16:23:32
-07'00'
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23
Engineerinc.io,
303 N Glenoaks Blvd
Burbank, CA 91502
(747) 333-5991
Professional Certification. I hereby certify that these documents
were prepared or approved by me, and that I am a duly licensed
professional engineer under the laws of the State of California.
License No. ____________, Expiration Date: _______________ 88083 03/31/2024
Digitally signed by
Manouchehr Hakhamaneshi
Date: 2023.06.28 08:38:10
'-07'00
421 S Huron Dr -
2018016207/03/23
Engineerinc.io,
303 N Glenoaks Blvd
Burbank, CA 91502
(747) 333-5991
Professional Certification. I hereby certify that these documents
were prepared or approved by me, and that I am a duly licensed
professional engineer under the laws of the State of California.
License No. ____________, Expiration Date: _______________ 88083 03/31/2024
Digitally signed
by Manouchehr
Hakhamaneshi
Date: 2023.06.28
'08:38:20 -07'00
421 S Huron Dr -
2018016207/03/23
Engineerinc.io,
303 N Glenoaks Blvd
Burbank, CA 91502
(747) 333-5991
Professional Certification. I hereby certify that these documents
were prepared or approved by me, and that I am a duly licensed
professional engineer under the laws of the State of California.
License No. ____________, Expiration Date: _______________ 88083 03/31/2024
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23
Engineerinc.io,
303 N Glenoaks Blvd
Burbank, CA 91502
(747) 333-5991
Professional Certification. I hereby certify that these documents
were prepared or approved by me, and that I am a duly licensed
professional engineer under the laws of the State of California.
License No. ____________, Expiration Date: _______________ 88083 03/31/2024
Digitally signed
by
Manouchehr
Hakhamaneshi
Date:
2023.06.28
'08:38:36 -07'00
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23
Engineerinc.io,
303 N Glenoaks Blvd
Burbank, CA 91502
(747) 333-5991
Professional Certification. I hereby certify that these documents
were prepared or approved by me, and that I am a duly licensed
professional engineer under the laws of the State of California.
License No. ____________, Expiration Date: _______________ 88083 03/31/2024
Digitally
signed by
Manouchehr
Hakhamaneshi
Date:
2023.06.28
08:37:43
'-07'00
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23
Engineerinc.io,
303 N Glenoaks Blvd
Burbank, CA 91502
(747) 333-5991
Professional Certification. I hereby certify that these documents
were prepared or approved by me, and that I am a duly licensed
professional engineer under the laws of the State of California.
License No. ____________, Expiration Date: _______________ 88083 03/31/2024
Digitally signed
by Manouchehr
Hakhamaneshi
Date:
2023.06.28
'08:38:47 -07'00
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23
Engineerinc.io,
303 N Glenoaks Blvd
Burbank, CA 91502
(747) 333-5991
Professional Certification. I hereby certify that these documents
were prepared or approved by me, and that I am a duly licensed
professional engineer under the laws of the State of California.
License No. ____________, Expiration Date: _______________ E 20878 09/30/2024
421 S Huron Dr -
2018016207/03/23
Engineerinc.io,
303 N Glenoaks Blvd
Burbank, CA 91502
(747) 333-5991
Professional Certification. I hereby certify that these documents
were prepared or approved by me, and that I am a duly licensed
professional engineer under the laws of the State of California.
License No. ____________, Expiration Date: _______________ E 20878 09/30/2024
421 S Huron Dr -
2018016207/03/23
Engineerinc.io,
303 N Glenoaks Blvd
Burbank, CA 91502
(747) 333-5991
Professional Certification. I hereby certify that these documents
were prepared or approved by me, and that I am a duly licensed
professional engineer under the laws of the State of California.
License No. ____________, Expiration Date: _______________ E 20878 09/30/2024
3. ALL ELECTRICAL EQUIPMENT SHALL BE UL LISTED OR
LABORATORY OR APPROVED BY THE DEPARTMENT.
1. ALL ELECTRICAL EQUIPMENT AND MATERIALS SHALL BE NEW
AND LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED
ELECTRICAL TESTING LABORATORY ACCREDITED BY THE UNITED
STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION.
2. ALL WORK SHALL COMPLY WITH THE STATE OF CALIFORNIA,
4. ALL EQUIPMENT SHALL BE GROUNDED PER
NATIONAL ELECTRICAL CODE.
ELECTRICAL PE NOTES:
LISTED BY A CITY OF SANTA ANA, RECOGNIZED ELECTRICAL
AND ALL SANTA ANA CITY APPLICABLE CODES AND REGULATIONS.
421 S Huron Dr -
2018016207/03/23
Professional Certification. I hereby certify that these documents
were prepared or approved by me, and that I am a duly licensed
professional engineer under the laws of the State of California.
License No. ____________, Expiration Date: _______________ 88083 03/31/2024
Engineerinc.io,
303 N Glenoaks Blvd
Burbank, CA 91502
(747) 333-5991
Prior to the commencement of work, the contractor shall verify the existing roof and
framing conditions. Notify New@engineerinc.io of any Discrepancies prior to starting
construction.
Prior to the commencement of work, the contractor shall inspect framing for any damage
such as water damage, cracked framing, etc. and notify New@engineerinc.io if any
issues are found.
These Plans are stamped for structural code compliance of the roof framing supporting
the proposed PV installation reference only. These plans are not stamped for water
leakage. PV modules, racking, and attachment components must follow manufacturer
guidelines and requirements.
421 S Huron Dr -
2018016207/03/23
THREE POWER SUPPLY
SOURCES:
1)UTILITY GRID
2)PV SOLAR ELECTRIC SYSTEM
3)TRANSFER SWITCH
690.56 Identification of Power Sources.
(C) Facilities with Rapid Shutdown.
Permanent directory or plaque providing location of service
disconnecting means and photovoltaic system disconnecting means, if
not located at the same location.
Plaques will have red background with white lettering.
CAUTION
MULTIPLE SOURCES OF POWER
WARNING
INVERTER OUTPUT CONNECTION. DO NOT
RELOCATE THIS OVERCURRENT DEVICE.
SOLAR ELECTRIC
PV PANELS
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH ON THE
"OFF" POSITION TO
SHUTDOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN ARRAY
WARNING
PHOTOVOLTAIC POWER
SOURCE
ELECTRIC SHOCK HAZARD.
IF GROUND FAULT IS INDICATED,
NORMALLY GROUNDED
CONDUCTORS MAY BE
UNGROUNDED AND ENERGIZED
PV SUB PANEL ONLY
Engineerinc.io,
303 N Glenoaks Blvd
Burbank, CA 91502
(747) 333-5991
Professional Certification. I hereby certify that these documents
were prepared or approved by me, and that I am a duly licensed
professional engineer under the laws of the State of California.
License No. ____________, Expiration Date: _______________ E 20878 09/30/2024
421 S Huron Dr -
2018016207/03/23
WARNING
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
WARNING
THIS EQUIPMENT FED BY MULTIPLE
SOURCES. TOTAL RATING OF ALL
OVERCURRENT DEVICES, EXCLUDING
MAIN SUPPLY OVERCURRENT DEVICE,
SHALL NOT EXCEED AMPACITY OF
BUSBAR.
CAUTION
TRI POWER SOURCE
SECOND SOURCE IS
AC BATTERY
THIRD SOURCE IS
PV INVERTER
WARNING
ELECTRIC SHOCK HAZARD IF A
GROUND FAULT IS INDICATED,
NORMALLY GROUNDED CONDUCTORS
MAY BE UNGROUNDED AND
ENERGIZED
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23
ENPHASE
Professional Certification. I hereby certify that these documents
were prepared or approved by me, and that I am a duly licensed
professional engineer under the laws of the State of California.
License No. ____________, Expiration Date: _______________ 88083 03/31/2024
Engineerinc.io,
303 N Glenoaks Blvd
Burbank, CA 91502
(747) 333-5991
The scope of the plans is for the installation of the solar photovoltaic
system only and the approval is subject to compliance with all
applicable city and state codes and regulations regarding construction.
The approval of the plans does not constitute any certification of the
accuracy, completeness, or building permit status of the existing
buildings and structures as shown.
Bldg# 101115649
Elec# 20180162
Approved MSmith
Issued 07/03/23
421 S Huron Dr -
2018016207/03/23
Rev: 7/15/2021
RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
SOL-01 CBC 2019
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only
Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and
sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of
minimum 11 x 17 size. If answering NO to any of the questions, plan check shall be required.
Project Address:
Contractor Company Name:
Contractor License Number:
YES NO Are the following applicable to the proposed project?
1. Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.11 of the California Fire Code, and is this shown on the roof plan?
2. Will the PV system be installed on a roof having only one roofing layer with no
overlays?
3. Will the PV array be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
4. Will the PV system weigh maximum 4 pounds per square feet or less?
5. Will the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
6. Will the PV system be installed with a space of 2 minimum to 10 maximum between
the underside of modules and the surface of the roof?
7. Will the PV system be installed without using any ballast system or counter-weight
system?
8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
9. Will the minimum 5/16 lag screws be installed with a minimum of 2-1/2 inch
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on the plans?
10. Are ALL the structural pages of the plans stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufacturers PV support information.)
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name: Signature:
Phone Number: Date:
Email Address:
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
421 S Huron Dr -
2018016207/03/23
421 S Huron Dr -
2018016207/03/23