Loading...
HomeMy WebLinkAbout525 S Marine St - Plan525 S Marine St 07/28/23 108'-0" 60 ' - 0 " 108'-0" 60 ' - 0 " 17'-5" 13'-7" 5' - 1 " 3' - 1 1 " N SHEET INDEX: PV 0.0: COVER SHEET PV 1.0: SITE PLAN PV 2.0 ATTACHMENT DETAILS E1.1: 3-LINE DIAGRAM E 1.2: NOTES E 1.3: WARNING LABELS EQUIPMENT SPEC SHEETS ROOF ACCESS POINT ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. SCALE: NTS 2 SATELLITE VIEW PV 0.0 SCALE: NTS 3 VICINITY MAP PV 0.0 SCALE: 1/16" = 1'-0" 1 PLOT PLAN PV 0.0 SYSTEM SIZE: 20.40 kW DC 14.79 kW AC MODULE TYPE & AMOUNT: (51)HANWHA Q.PEAK DUO BLK ML-G10+(400W) MODULE DIMENSIONS: (L/W/H) 74.0"/41.1"/1.26" INVERTER: (51)ENPHASE IQ8PLUS-72-2-US, 240V INTERCONNECTION METHOD: BACKFEED BREAKER PHOTOVOLTAIC SYSTEM SPECIFICATIONS: PHOTOVOLTAIC ROOF MOUNT SYSTEM 51 MODULES-ROOF MOUNTED - 20.40 kW DC, 14.79 kW AC, 525 S MARINE ST, SANTA ANA, CA 92704 GENERAL NOTES: a. INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING. b. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110. c. ALL CONDUCTORS, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250. d. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES. e. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE. f. PV MODULES TO BE RATED UL 1703 CLASS C FIRE RATING OR BETTER. g. ALL EQUIPMENT TO BE CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. EXISTING EXTERIOR METER/MAIN COMBO.SERVICE PANEL TIED TO EXTERIOR UTILITY METER KE L L Y N G U Y E N RE S I D E N C E 52 5 S M A R I N E S T , SA N T A A N A , C A 9 2 7 0 4 Project Name & Address Sheet Number PV 0.0 Sheet Name DRAWN BY YG CO U N T Y - S A N T A A N A DATE: 04/13/2023 AH J - O R A N G E C O U N T Y 32203 VIA BENABARRE, TEMECULA CA USA 92592 CSLB # : 978840 EMAIL: JEREMY@POWERCONSULTATIONS.COM TIME SAVER ELECTRIC EXISTING EXTERIOR METER/MAIN SERVICE PANEL & POINT OF INTERCONNECTION. TIED TO EXTERIOR UTILITY METER. SYSTEM LEGEND NEW DEDICATED PV SYSTEM COMBINER PANEL.C NEW 100A NON-FUSED AC DISCONNECTAC COVER SHEET TOTAL ROOF AREA 3252 SqFt C A C GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 1. 2022 CA BUILDING CODE 2. 2022 CA ENERGY CODE 3. 2022 CA ELECTRICAL CODE 4. 2022 CA FIRE CODE TITLE 24 SUPPLEMENT 5. 2022 CA GREEN CODE 6. 2022 CA MECHANICAL CODE 7. 2022 CA PLUMBING CODE 8. 2022 CA RESIDENTIAL CODE 9. ANY OTHER LOCAL AMENDMENTS (E)GATE (TYP.) M M PROPERTY LINE PR O P E R T Y L I N E BA C K O F H O U S E 52 5 S M A R I N E S T FR O N T O F H O U S E PROPERTY LINE PR O P E R T Y L I N E ROOF #1 (29)HANWHA Q.PEAK DUO BLK ML-G10+(400W) SLOPE: 26° AZIM.: 270° ROOF #2 (10) HANWHA Q.PEAK DUO BLK ML-G10+(400W) SLOPE: 26° AZIM.: 90° ROOF #4 (04) HANWHA Q.PEAK DUO BLK ML-G10+(400W) SLOPE: 21° AZIM.: 180°ROOF #3 (08)HANWHA Q.PEAK DUO BLK ML-G10+(400W) SLOPE: 21° AZIM.: 90° ROOF ACCESS POINT (E)FENCE DRIVEWAY GARAGE (E ) M A I N H O U S E 1 - S T O R Y H O U S E (E)GATE (TYP.) (E)GATE (TYP.) Signed 07/11/2023 PORCH COVER PATIO COVER The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 102115780 Issued 07/18/23 Elec# 20280256 Approved by MSmith Issued 07/24/23 525 S Marine St 07/28/23 KE L L Y N G U Y E N RE S I D E N C E 52 5 S M A R I N E S T , SA N T A A N A , C A 9 2 7 0 4 Project Name & Address Sheet Number DS 2.2 Sheet Name DRAWN BY YG CO U N T Y - S A N T A A N A DATE: 04/13/2023 AH J - O R A N G E C O U N T Y 32203 VIA BENABARRE, TEMECULA CA USA 92592 CSLB # : 978840 EMAIL: JEREMY@POWERCONSULTATIONS.COM TIME SAVER ELECTRIC EQUIPMENT SPEC SHEETS Signed 07/11/2023 525 S Marine St 07/28/23 KE L L Y N G U Y E N RE S I D E N C E 52 5 S M A R I N E S T , SA N T A A N A , C A 9 2 7 0 4 Project Name & Address Sheet Number DS 2.3 Sheet Name DRAWN BY YG CO U N T Y - S A N T A A N A DATE: 04/13/2023 AH J - O R A N G E C O U N T Y 32203 VIA BENABARRE, TEMECULA CA USA 92592 CSLB # : 978840 EMAIL: JEREMY@POWERCONSULTATIONS.COM TIME SAVER ELECTRIC EQUIPMENT SPEC SHEETS Signed 07/11/2023 525 S Marine St 07/28/23 KE L L Y N G U Y E N RE S I D E N C E 52 5 S M A R I N E S T , SA N T A A N A , C A 9 2 7 0 4 Project Name & Address Sheet Number DS 2.4 Sheet Name DRAWN BY YG CO U N T Y - S A N T A A N A DATE: 04/13/2023 AH J - O R A N G E C O U N T Y 32203 VIA BENABARRE, TEMECULA CA USA 92592 CSLB # : 978840 EMAIL: JEREMY@POWERCONSULTATIONS.COM TIME SAVER ELECTRIC EQUIPMENT SPEC SHEETS Signed 07/11/2023 525 S Marine St 07/28/23 N KE L L Y N G U Y E N RE S I D E N C E 52 5 S M A R I N E S T , SA N T A A N A , C A 9 2 7 0 4 Project Name & Address Sheet Number PV 1.0 Sheet Name DRAWN BY YG CO U N T Y - S A N T A A N A DATE: 04/13/2023 AH J - O R A N G E C O U N T Y 32203 VIA BENABARRE, TEMECULA CA USA 92592 CSLB # : 978840 EMAIL: JEREMY@POWERCONSULTATIONS.COM TIME SAVER ELECTRIC SITE PLAN ROOF SECTIONS SCALE: 1/8" = 1'-0" 1 SITE PLAN PV 1.0 SYSTEM LEGEND 51 NEW HANWHA Q.PEAK DUO BLK ML-G10+(400W) WITH NEW 51 - ENPHASE IQ8PLUS-72-2-US, 240V INVERTERS, MOUNTED ON THE BACK OF EACH MODULES. = EXTERIOR RUN = ATTIC RUN = CONDUIT ROOF TOP JUNCTION BOX = CONDUIT ATTIC RUN JUNCTION BOX = ATTACHMENT POINTS = ROOF OBSTRUCTIONS, VENT, CHIMNEY CIRCUIT #4 - 12 MODULES CIRCUIT #3 - 13 MODULES CIRCUIT #2 - 13 MODULES CIRCUIT #1 - 13 MODULES CIRCUIT(S) NEW JUNCTION BOXJB = RAFTER MODULE, ARRAY WEIGHT (LOAD CALC'S) Number of Modules 51 Module Weight 48.5 LBS Total Module (Array) Weight 2473.50 LBS Number of Attachment point 32 Mounting System Weight (Per Module)1.5 LBS Mounting System Weight 48.00 LBS Total System Weight (Module Weight + Mounting System Weight)2521.50 LBS Weight at Each Attachment Point (Array Weight / Number of Attachment Point)77.30 LBS Module Area (74.0"x41.1")21.12 SqFt Total Array Area 1077.16 SqFt Distributed Load (Total System Weight / Total Array Area)2.37 Per SqFt Total Roof Area 3252 SqFt Total Percentage or Roof Covered Total Array Area / Total Roof Area)*100 33.12% = FIRE SETBACK & PATHWAY ATTACHMENT SPACING : 4'-0" EXISTING EXTERIOR METER/MAIN SERVICE PANEL & POINT OF INTERCONNECTION. TIED TO EXTERIOR UTILITY METER. NEW DEDICATED PV SYSTEM COMBINER PANEL.C NEW 100A NON-FUSED AC DISCONNECTAC M MODULE - 08 SLOPE - 21° AZIMUTH - 90° MATERIAL - COMP SHINGLE RAFTER SIZE & SPACING - 2"X4" @ 24" O.C. MODULE - 10 SLOPE - 26° AZIMUTH - 90° MATERIAL - COMP SHINGLE RAFTER SIZE & SPACING - 2"X4" @ 24" O.C. MODULE - 29 SLOPE - 26° AZIMUTH - 270° MATERIAL - COMP SHINGLE RAFTER SIZE & SPACING - 2"X4" @ 24" O.C. MODULE - 04 SLOPE - 21° AZIMUTH - 180° MATERIAL - COMP SHINGLE RAFTER SIZE & SPACING - 2"X4" @ 24" O.C. ROOF #01 ROOF #02 ROOF #03 ROOF #04 ROOF #04 36" FIRE PATHWAY C AC M JB BA C K O F H O U S E 36" FIRE PATHWAY RO O F # 0 1 RO O F # 0 2 RO O F # 0 3 36" FIRE SETBACK 36" FIRE PATHWAY 36" FIRE PATHWAY 36 " F I R E S E T B A C K 52 5 S M A R I N E S T FR O N T O F H O U S E 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K 36" F I RE P A T H W A Y JB JB JB JB Signed 07/11/2023 525 S Marine St 07/28/23 KE L L Y N G U Y E N RE S I D E N C E 52 5 S M A R I N E S T , SA N T A A N A , C A 9 2 7 0 4 Project Name & Address Sheet Number PV 2.0 Sheet Name DRAWN BY YG CO U N T Y - S A N T A A N A DATE: 04/13/2023 AH J - O R A N G E C O U N T Y 32203 VIA BENABARRE, TEMECULA CA USA 92592 CSLB # : 978840 EMAIL: JEREMY@POWERCONSULTATIONS.COM TIME SAVER ELECTRIC ATTACHMENT DETAIL GENERAL STRUCTURAL NOTES: 1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING ROCK IT ECOFASTEN ATTACHMENT. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND MUST BE STAGGERED TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2-1/2" PENETRATION INTO ROOF FRAMING. 3. THE PROPOSED PV SYSTEM ADDS 2.6 PSF TO THE ROOF FRAMING SYSTEM. 4. ROOF LIVE LOAD = 20 PSF TYPICAL, 0 PSF UNDER NEW PV SYSTEM. 5. SNOW LOAD = 5 LB/SQFT 6. WIND SPEED = 115 MPH 7. EXPOSURE CATEGORY = C 8. MAX SPACING BETWEEN ATTACHMENTS (INCHES) = 48" ROCK-IT SLIDE FLAT TILE FLASHING EPDM BONDED WASHER FORMS WATERTIGHT SEAL TILE BASE 3" M I N . S 1.0 1 ROCK-IT MOUNT DETAIL NOT TO SCALE (2) MIN 5 16" SS LAG SCREW TORQUE=13±2 FT-LBS. PILOT HOLE BACKFILLED WITH SEALANT PRIOR TO LAG INSTALLATION RAIN BUSTER IS APPLIED TO THE UP-SLOPE EDGE OF THE TILE BASE AS WELL AS TO THE LOCATIONS OF THE LAG SCREW. 2 1 2" EMBEDMENT TOP VIEW COUPLING CLAMP + ATTACHMENT COUPLING CLAMP + ATTACHMENT L=PORTRAIT CLAMP SPACING PERMITTED CLAMP SPACING MODULE L=LANDSCAPE CLAMP SPACING MODULE MODULE COUPLING TRUSSES CLAMP RAFTER CANTILEVER L/3 OR LESS TRUSSES S 1.0 5 MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALES 1.0 4 PV SYSTEM MOUNTING DETAIL NOT TO SCALE S 1.0 6 PV ARRAY TYP. ELEVATION NOT TO SCALE PV MODULE, TYP. MOUNT TO FRAMING OF EXISTING ROOF TYPE, PARALLEL WITH PLANE OF ROOF 1 S 1.0 S 1.0 7 CONDUIT MOUNTING DETAIL NOT TO SCALE 3" MIN AND 6" MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE 6" MA XIMU M U.L. LISTING FOR ECOFASTEN: 2703 WEIGHT: 2.3 lb. S 1.0 3 ILSCO SGB-4 GROUNDING LUGS NOT TO SCALE CONDUITONE HOLE STEEL STRAP CONDUIT MOUNT BRACKET FLASHING/TILE STRAP 1 1 / 2 " SIDE VIEW ROCK-IT 3.0 COUPLING MID CLAMP ROCK-IT COUPLING SHELF TIE PLATE 5/16"x1 1/2" HEX FLANGE BOLT 300 SERIES SS TILE ROOF TOP ISOMETRIC VIEW ROCK-IT COUPLING MID CLAMP ROCK-IT COUPLING SHELF S 1.0 2 ROCK-IT COUPLING ASSEMBLY NOT TO SCALE LANDSCAPE=MAX 72" (6'-0") PORTRAIT=MAX 48" (4'-0") 3" TRUSSES #### AT #### Signed 07/11/2023 525 S Marine St 07/28/23 KE L L Y N G U Y E N RE S I D E N C E 52 5 S M A R I N E S T , SA N T A A N A , C A 9 2 7 0 4 Project Name & Address Sheet Number E 1.1 Sheet Name DRAWN BY YG CO U N T Y - S A N T A A N A DATE: 04/13/2023 AH J - O R A N G E C O U N T Y 32203 VIA BENABARRE, TEMECULA CA USA 92592 CSLB # : 978840 EMAIL: JEREMY@POWERCONSULTATIONS.COM TIME SAVER ELECTRIC 3-LINE DIAGRAM (N)JUNCTION BOX 600 V, NEMA 4 UL LISTED G NG 15A 1 L2 L113 MICRO-INVERTERS IN BRANCH CIRCUIT #3 (N)125A COMBINER PANEL ENPHASE IQ COMBINER X-IQ- AM1-240-4 64A/240V CONTINUOUS,PROTECTION MAX 80A BREAKER ON SOLAR OUTPUT; WITH 10 KAIC CIRCUIT BREAKERS TERMINATOR CAP ON LAST CABLE CONNECTOR AC TRUNK CABLE (TYP) M* IQ Envoy 20A 2 G N 3 EXISTING SCE UTILITY METER L2 L1 3 (N)100A NON-FUSED AC DISCONNECT, 240V (EXTERIOR MOUNTED) LOAD SIDE INTERCONNECTION AT MAIN PANEL PER ART. 705.12(B) (N)(51) ENPHASE IQ8PLUS-72-2-US, 240V, MICRO-INVERTERS, 240V, 1.21A MAX CEC WEIGHTED EFFICIENCY 97.0% NEMA 4R, UL LISTED, INTERNAL GFDI MODULE TYPE & AMOUNT: (51) HANWHA Q.PEAK DUO BLK ML-G10+(400W) MICRO-INVERTER: (51) ENPHASE IQ8PLUS-72-2-US, 240V (03)CIRCUITS OF 13 MODULES & (01) 12 MODULES CONNECTED IN PARALLEL SYSTEM SIZE: 20.40 KW DC 14.79 KW AC "ALL EXPOSED PV ROOFTOP CONDUCTORS THAT ARE NOT LOCATED UNDER THE ARRAY MODULES, SHALL INCLUDE LISTED JUNCTION BOXES AT BOTH ENDS OF THE RACEWAY TO TRANSITION FROM EXPOSED CONDUCTORS TO THE LISTED RACEWAYS." SOLAR BREAKER LOCATED AT THE FURTHEST END OF BUSBAR FROM THE MAIN BREAKER OR FEEDER UNIT ALL CABLES ON ROOF MUST BE UNDER SOLAR PANELS AND/OR IN CONDUIT 120% RULE BUS BAR RATING X 120%) - MAIN BREAKER RATING = MAX. PV OCPD (225A x 120%) - 175 = 95A NOTE: TO AVOID EXTRA TEMP. CORRECTIONS CONDUIT MUST BE 7/8” MINIMUM HEIGHT OFF ROOFTOP (EXTERIOR) OR 18” BELOW ROOF THROUGH ATTIC (INTERIOR). EXISTING GROUNDING ELECTRODE SYSTEM TO EARTH REF. NEC 250.52, 250.53(A) EXISTING 240V/225A RATING, METER/MAIN COMBO PANEL, SINGLE PHASE, WITH (N) 175A MAIN BREAKER(BOTTOM FED) GEC12 11 PRODUCTION CT WIRE QTY WIRE TAG #CONDUIT WIRE TYPE INVERTER QTY:NOC: CONDUIT FILL: TEMP RATING:WIRE AMP TEMP DE-RATE: WIRE OCP:GRND SIZE GRND WIRE TYPE ENPHASE TRUNK CABLE INCLUDES #12 GROUND WIRE GAUGE: TERMINAL 75°C RATING: NEC: STRING AMPS x x = x x =1.251.21 13 #6 SBC23.04A 90° x x = 26.88A 90° 3/4" EMT WIRE FROM - - JUNCTION BOX TO COMBINER PANEL ARRAY TO JUNCTION BOX 2 TRUNK CABLE PV WIRE x x =1.251.21 51 #8 THWN-277.14A x x = 90° 1" EMT COMBINER PANEL TO MSP 3 NEC 310.15 (B)(2)(a) NEC 690.8(B) NEC 310.15 (B)(3)(a) NEC 310. 15(B)(3)(c) 1 19.66A x x =1.251.21 13 19.66A 30A #12 40A #10 95A #4 4 0.80A 8 0.70A 3 1.00 0.96 0.96 0.96 25A 35A 85A THWN-2 #10 THWN-2 THWN-2 91.20A G N (N)80A/2P (E)LOADS (N)175/2PA M (E)LOADS 13 MICRO-INVERTERS IN BRANCH CIRCUIT #2 L2 L1 20A (E)LOADS MSP DERATE - YES TERMINATOR CAP ON LAST CABLE CONNECTOR AC TRUNK CABLE (TYP) 13 MICRO-INVERTERS IN BRANCH CIRCUIT #1 TERMINATOR CAP ON LAST CABLE CONNECTOR AC TRUNK CABLE (TYP) TERMINATOR CAP ON LAST CABLE CONNECTOR AC TRUNK CABLE (TYP) 12 MICRO-INVERTERS IN BRANCH CIRCUIT #4 TERMINATOR CAP ON LAST CABLE CONNECTOR AC TRUNK CABLE (TYP) L2 L1 L2 L1 20A 20A (N)80A BACKFED BREAKER (4) ENPHASE Q CABLES Signed 07/11/2023 525 S Marine St 07/28/23 KE L L Y N G U Y E N RE S I D E N C E 52 5 S M A R I N E S T , SA N T A A N A , C A 9 2 7 0 4 Project Name & Address Sheet Number E 1.2 Sheet Name DRAWN BY YG CO U N T Y - S A N T A A N A DATE: 04/13/2023 AH J - O R A N G E C O U N T Y 32203 VIA BENABARRE, TEMECULA CA USA 92592 CSLB # : 978840 EMAIL: JEREMY@POWERCONSULTATIONS.COM TIME SAVER ELECTRIC NOTES NOTES THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) AC OUTPUT CURRENT NOMINAL AC VOLTAGE 240V 61.71A Rooftop conductor ampacities designed in compliance with art. 690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9. Location specific temperature obtained from ASHRAE 2022 data tables AMBIENT TEMP (HIGH TEMP 2%) RECORD LOW TEMP -2° 38° CONDUIT HEIGHT 7/8" CONDUCTOR TEMPERATURE RATE 90° SYSTEM NOTES: 1. ENPHASE IQ8PLUS-72-2-US, (240V) MICROINVERTERS DO NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS OR EQUIPMENT GROUNDING CONDUCTORS. THE MICROINVERTERS ITSELF HAS CLASS II DOUBLE-INSULATED RATING, WHICH INCLUDES GROUND FAULT PROTECTION. 2. ENPHASE Q CABLE HAS NO NEUTRAL WIRE - (2 WIRE DOUBLE INSULATED CABLING) 3. MODULES ARE BONDED TO RAIL USING IRONRIDGE INTEGRATED GROUNDING. 4. RAILS ARE BONDED WITH UL 2703 RATED LAY-IN LUGS 5. SYSTEM IS UNGROUNDED 6. BARE COPPER IS TRANSITIONED TO THHN/THWN-2 VIA IRREVERSIBLE CRIMP; GEC TO BE CONTINUOUS PER CEC 250.64(C) 7. SUB-BRANCHES ARE CENTER-FED AT JBOX TO MAKE ONE TOTAL BRANCH CIRCUIT. 8. ENPHASE IQ ENVOY INSIDE IQ COMBINER REQUIRES A NEUTRAL TO BE LANDED AT THE NEUTRAL BUSS AT MAIN PANEL PER ENPHASE INSTALLATION INSTRUCTIONS. 9. ENPHASE MICROINVERTERS ARE ALL RAPID SHUTDOWN READY PER NEC 690.12 ENPHASE Q CABLE TO BE ATTACHED TO RAIL MIN. 3-1/2" ABOVE ROOF SURFACE MANUFACTURER MAX. POWER AT 40 C 60 VOLTS NOMINAL AC VOLTAGE 290 WATTS MAX. AC CURRENT 240 VOLTS MAX. OCPD RATING MAX. PANELS/CIRCUIT SHORT CIRCUIT CURRENT 1.21 AMPS 20 AMPS MAX. DC VOLT RATING 13 15 AMPS ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTER PER MANUFACTURER SPECIFICATIONS 1. THIS SYSTEM SHALL COMPLY WITH ALL APPLICABLE CODES INCLUDING: THE 2022 CALIFORNIA BUILDING CODE, CALIFORNIA FIRE CODE, CALIFORNIA ELECTRIC CODE, CALIFORNIA MECHANICAL CODE CALIFORNIA RESIDENTIAL CODE, CALIFORNIA PLUMBING CODE, CALIFORNIA BUILDING STANDARDS CODE, CALIFORNIA HEALTH AND SAFETY CODE, IEEE STANDARD 929, UL STANDARD 1741, 2016 RESIDENTIAL CODE, AND THE MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. 2. ALL WORK TO COMPLY WITH CEC ARTICLE 690 3. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM 4. REMOVAL OF A UTILITY-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BUILDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PV SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR 5. ALL PV SYSTEM COMPONENTS SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY 6. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT AT 25° C; WIRE SHALL BE WET RATED AT 90°C 7. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE USE-2 OR PV TYPE WIRE. 8. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS (NEC 314.15) 9. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS (NEC 250.90, 250.96) 10. FOR UNGROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED WITH A GROUND-FAULT PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS OCCURED, AND AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS (CEC 690.35(C)) 11. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT (CEC 250.64C) 12. ALL PV MODULES AND ASSOCIATED EQUIPMENT SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE 13. ALL FIELD-INSTALLED JUNCTION, PULL, AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE SECURED BY REMOVABLE FASTENERS 14. FOR GROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT PROTECTION AND A GFI FUSE PORT FOR GROUND FAULT INDICATION 15. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKERS SHALL NOT READ "LINE AND LOAD" 16. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT OF LESS THAN 4 PSF 17. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 45 LBS 18. AC DISCONNECT IS A "KNIFE BLADE" TYPE DISCONNECT 19. THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26 20. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 COMPLIANT 21. SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED ONTO THE EXISTING DWELLING AS PER THE 2016 CRC. THESE SMOKE ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. THESE ALARMS MAY BE SOLELY BATTERY OPERATED IF THE PHOTOVOLTAIC PROJECT DOES NOT INVOLVE THE REMOVAL OF INTERIOR WALL AND CEILING FINISHES INSIDE THE HOME; OTHERWISE, THE ALARMS MUST BE HARD WIRED AND INTERCONNECTED. (CRC R314, R315) 22. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTIONS R314 AND 315 TO BE VERIFIED AND INSPECTED BY THE INSPECTOR IN THE FIELD. 23. WHEN APPLYING THE 120% RULE OF CEC 705.12(D)(2), THE SOLAR BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUS FROM THE MAIN BREAKER PER 705.12(D)(7) 24. PLUMBING AND MECHANICAL VENTS THROUGH THE ROOF SHALL NOT BE COVERED BY SOLAR MODULES - NO BUILDING, PLUMBING, OR MECHANICAL VENTS TO BE COVERED OR OBSTRUCTED MANUFACTURER MAX. POWER-POINT CURRENT (IMP) MAX. POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) 10.77 AMPS 37.13 VOLTS 45.30 VOLTS 11.14 AMPS NOM. MAX. POWER AT STC (PMAX) VOC TEMPERATURE COEFFICIENT 400 WATT -0.27° %/°C HANWHA Q.PEAK DUO BLK (400W) SOLAR MODULE PER MANUFACTURER SPECIFICATIONS Signed 07/11/2023 525 S Marine St 07/28/23 N KE L L Y N G U Y E N RE S I D E N C E 52 5 S M A R I N E S T , SA N T A A N A , C A 9 2 7 0 4 Project Name & Address Sheet Number E 1.3 Sheet Name DRAWN BY YG CO U N T Y - S A N T A A N A DATE: 04/13/2023 AH J - O R A N G E C O U N T Y 32203 VIA BENABARRE, TEMECULA CA USA 92592 CSLB # : 978840 EMAIL: JEREMY@POWERCONSULTATIONS.COM TIME SAVER ELECTRIC WARNING LABELS CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN 52 5 S M A R I N E S T (N)PV ARRAY NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2016 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ELECTRICAL SHOCK HAZARD WARNING ! LABEL LOCATION: INVERTER(S), DC DISCONNECTS. PER CODE(S): CEC 2022: 690.35(F), NEC 2014: 690.35(F), NEC 2011: 690.35(F) WARNING! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2014: 705.12(D)(3), NEC 2011: 705.12(D)(4) ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED WARNING LABEL LOCATION: INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF APPLICABLE). PER CODE(S): CEC 2022: 690.15, NEC 2014: 690.5(C), NEC 2011: 690.5(C) ! ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING ! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 690.17(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) WARNING ! DO NOT RELOCATE THIS OVERCURRENT DEVICE INVERTER OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2022: 705.12(B), NEC 2014: 705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7) ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2022: 705.12(D)(2)(3)(c), NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) WARNING: PHOTOVOLTAIC POWER SOURCE WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): CEC 2022: 690.13, NEC 2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2022: 690.53, NEC 2014: 690.54, NEC 2011: 690.54 MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 61.71 AMPS 240 VAC PHOTOVOLTAIC AC DISCONNECT PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL LOCATION: WEATHER RESISTANT MATERIAL, DURABLE PLAQUE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD, PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.12, 690.56(C)) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS (E)METER/MAIN COMBO.PANEL (N)AC COMBINER PANEL (N)100A NON-FUSED AC DISCONNECT Signed 07/11/2023 525 S Marine St 07/28/23 KE L L Y N G U Y E N RE S I D E N C E 52 5 S M A R I N E S T , SA N T A A N A , C A 9 2 7 0 4 Project Name & Address Sheet Number DS 1.0 Sheet Name DRAWN BY YG CO U N T Y - S A N T A A N A DATE: 04/13/2023 AH J - O R A N G E C O U N T Y 32203 VIA BENABARRE, TEMECULA CA USA 92592 CSLB # : 978840 EMAIL: JEREMY@POWERCONSULTATIONS.COM TIME SAVER ELECTRIC EQUIPMENT SPEC SHEETS Signed 07/11/2023 525 S Marine St 07/28/23 KE L L Y N G U Y E N RE S I D E N C E 52 5 S M A R I N E S T , SA N T A A N A , C A 9 2 7 0 4 Project Name & Address Sheet Number DS 2.0 Sheet Name DRAWN BY YG CO U N T Y - S A N T A A N A DATE: 04/13/2023 AH J - O R A N G E C O U N T Y 32203 VIA BENABARRE, TEMECULA CA USA 92592 CSLB # : 978840 EMAIL: JEREMY@POWERCONSULTATIONS.COM TIME SAVER ELECTRIC EQUIPMENT SPEC SHEETS Signed 07/11/2023 525 S Marine St 07/28/23 KE L L Y N G U Y E N RE S I D E N C E 52 5 S M A R I N E S T , SA N T A A N A , C A 9 2 7 0 4 Project Name & Address Sheet Number DS 2.1 Sheet Name DRAWN BY YG CO U N T Y - S A N T A A N A DATE: 04/13/2023 AH J - O R A N G E C O U N T Y 32203 VIA BENABARRE, TEMECULA CA USA 92592 CSLB # : 978840 EMAIL: JEREMY@POWERCONSULTATIONS.COM TIME SAVER ELECTRIC EQUIPMENT SPEC SHEETS Signed 07/11/2023 525 S Marine St 07/28/23 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Coleman D. Larsen, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com TIME SAVER ELECTRIC 32203 VIA BENABARRE, TEMECULA CA USA 92592 Re: Engineering Services Nguyen Residence ST, Santa Ana, CA 92704 20.400 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: 2x4 dimensional Rafters at 24” on center. Roof Material: Comp Shingle Roof Slope: 20 degrees Attic Access: Accessible Foundation: Permanent • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 psf C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 2.6 psf o New Solar Panels and Racking = 3 psf o TOTAL = 5.6 PSF • Live Load = 20 psf (reducible) – 0 psf at locations of solar panels • Ground Snow Load = 5 psf • Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 1 15 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2022 California Building Code, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. July 11 , 2023 525 S Marine St 07/28/23 Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Ecofasten Rock it installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2.The maximum allowable withdrawal force for a 5/16” lag screw is 235 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of 2½” embedment will be adequate and will include a sufficient factor of safety. 3.Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 72” on centers. 4.Panel supports connections shall be staggered to distribute load to adjacent framing members. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2022 CBC, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE California License No. 83664 Signed 07/11/2023 525 S Marine St 07/28/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.Will the PV system weigh maximum 4 pounds per square feet or less? 5.Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.Will the PV system be installed without using any ballast system or counter-weight system? 8.Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.Will the minimum 5/16” lag screws be installed with a minimum of 2 -1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 525 S. Marine St. Santa Ana CA 92704 Jeremy Allen 978840 Jeremy Allen (562) 449-7854 06/26/23 jeremy@powerconsultations.com Jeremy Allen 525 S Marine St 07/28/23