5402 W Lehnhardt Ave - Plan
TRANG DO RESIDENCE 5402 W LEHNHARDT AVE., SANTA ANA, CA 92704 SIGNED & STAMP BY DATE 10/14/2024 PROJECT ID OPS 034-874 CREATED BY SS CHECKED BY RB SCALE SHEET SIZE 11"X 17" ANSI B # REVISION/UPDATE DATE B REVISION 11/04/2024 SHEET INFORMATIONHOMEOWNER INFO SHEET NO. APN NUMBER: 10859132 PV-0 PHONE NO: (714) 548-0899 Luxor Energy, Inc 11740 Sterling Ave, Riverside, CA 92503 C10 LICENSE Lic No. #1102673 www.myluxorenergy.com SATELLITE VIEW (SCALE: NTS) · PROPOSED PROJECT TO INSTALL GRID- TIED PV + ESS SYSTEM ON AN EXISTING ROOFTOP STRUCTURE AT A RESIDENTIAL LOCATION: 5402 W LEHNHARDT AVE., SANTA ANA, CA 92704. COORDINATES: 33.732840, -117.939564 · THE PV MODULES WILL BE SECURED ON ROOF USING PRE-ENGINEERED ROOF RACKING SYSTEM. · INSTALLED PV SYSTEM WILL BE THEN CONCECTED TO HOMEOWNER'S SERVICE EQUIPMENT USING APPLICABLE INTERCONCECTION METHOD (AS PER AHJ). · THE ENERGY PRODUCED BY PV SYSTEM WILL BE USED TO POWER THE HOME APPLIANCES. EXCESS POWER IS SENT BACK TO THE UTILITY GRID. SCOPE OF WORK SHEET INDEX PROJECT LOCATION (SCALE: NTS) DESIGN CRITERIA ·CONSTRUCTION: SINGLE FAMILY DWELLING (SFD) ·NO. OF STORIES: DOUBLE STORY ·EXPOSURE CATEGORY : B, RISK CATEGORY : II ·WIND SPEED (ASCE 7-16) : 95 MPH ·GROUND SNOW LOAD (ASCE 7-16) : 0 lb/sqft ·ASHRAE EXTREME LOW: 2°C ·ASHRAE HIGH TEMP (2% AVG.) : 31°C ·ASHRAE DISTANCE ABOVE ROOF (7/8") : 53°C PV-0 PROJECT SUMMARY PV-1 SITE PLAN PV-2 ROOF ATTACHMENT DETAILS PV-3 BOM & STRING LAYOUT S-1 STRUCTURAL DETAILED DIAGRAM S-2 EQUIPMENT ELEVATION DIAGRAM E-1 ELECTRICAL DIAGRAM & CALCULATION E-2 PLACARDS E.S EQUIPMENT SPECIFICATIONS [ DC ] SYSTEM SIZE [ AC ] SYSTEM SIZE (15) MODULES x 425W (1) INVERTER x 5760W 6.375 kW 5.760 kW PROJECT: PV SYSTEM DETAILS PROJECT SUMMARY · THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONCECTION SHALL BE INSTALLED ONLY BY QUALIFIED PEOPLE. A QUALIFIED PERSON IS ONE WHO HAS SKILLS AND KNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OF THE ELECTRICAL EQUIPMENT AND INSTALLATIONS AND HAS RECEIVED SAFETY TRAINING TO RECOGNIZE AND AVOID THE HAZARDS INVOLVED. (CEC690.4(E) AND 705.6) ·LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. FOR A LINE SIDE TAP CONCECTION, UTILITY NEEDS TO BE NOTIFIED WELL IN ADVANCE TO COORDINATE BUILDING ELECTRICAL SHUT OFF. ·NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC. SUBCONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONS AND THE COORDINATION REQUIREMENTS OF OTHER TRADES. ·ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TO QUALIFIED PERSONNEL. ·ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WATERTIGHT AND APPROVED FOR USE IN WET LOCATIONS . ·WIRING METHODS FOR PV SYSTEM CONDUCTORS AREN'T PERMITTED WITHIN 10 IN. OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE LOCATED DIRECTLY BELOW THE ROOF SURFACE THAT'S COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT WIRING ·BACK-FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. ·ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARE LISTED AS UV RESISTANT. ·CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS ACCORDING TO CEC. ·MEASURE THE LINE-TO-LINE AND LINE-TO-NEUTRAL VOLTAGE OF ALL SERVICE ENTRANCE CONDUCTORS PRIOR TO INSTALLING ANY SOLAR EQUIPMENT. THE VOLTAGES FOR THE 240VAC RATED. ·ALL EXTERIOR CONDUIT TO BE PAINT MATCHED TO THE HOMES COLORS ELECTRICAL NOTES NTS · ALL COMPONENTS ARE UL LISTED & CEC CERTIFIED, WHERE WARRANTED · A DISCONNECTING MEANS SHALL BE INSTALLED AT A READILY ACCESSIBLE LOCATION EITHER OUTSIDE OF THE BUILDING OR STRUCTURE OR INSIDE NEAREST POINT OF ENTRANCE OF THE SYSTEM CONDUCTORS. · HEIGHT OF THE INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6'-7" PER CEC CODE 240.24. · A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE PROVIDED. PER CEC · GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. · PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE. · PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS. · WATER PROOF CONCECTORS AND HUBS SHALL BE USED WHERE APPLICABLE PER CEC 312.2 AND 314.15. · GROUNDING/BONDING BUSHINGS SHALL BE INSTALLED WHERE APPLICABLE PER CEC 250.92. · ALL EXTERIOR RACEWAYS ON WALLS SHOULD BE EMT UNLESS NOTED OTHERWISE. · CONTRACTOR SHALL INSTALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS & NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. · CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS & DETAILS IN THIS DOCUMENT. ALL DIMENSIONS SHALL BE VERIFIED BY SUBCONTRACTOR BEFORE INSTALLATION. PHOTOVOLTAIC SYSTEM FIRE CLASSIFICATION LISTING IN ACCORDANCE WITH UL1703 STANDARD. GENERAL NOTES APPLICABLE GOVERNING CODES & NOTES THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES: · 2022 CALIFORNIA BUILDING CODE · 2022 CALIFORNIA RESIDENTIAL CODE · 2022 CALIFORNIA MECHANICAL CODE · 2022 CALIFORNIA PLUMBING CODE · 2022 CALIFORNIA ENERGY CODE · 2022 CALIFORNIA FIRE CODE · 2022 CALIFORNIA ELECTRICAL CODE ALL OTHER RELATED STATE, LOCAL & AHJ AMENDMENTS. PROJECT INFORMATION (#) PV MODULES (15) JINKO SOLAR JKM425N-54HL4-B (#)OPTIMIZERS (15) SOLAREDGE POWER OPTIMIZER S500B (#)INVERTER (1) SOLAREDGE ENERGY HUB SE5700H-US INVERTER (#)BATTERY (01) SOLAREDGE ENERGY BANK BATTERY (10KW) (BAT-10K1PS0B-02) SYSTEM OUTPUT CURRENT 24.00A STRING 1 STRING OF 08 MODULES & 1 STRINGS OF 07 MODULES ROOF RACKING SYSTEM IRONRIDGE QUICKMOUNT HALO ULTRAGRIP W/ IRONRIDGE XR-10 POINT OF INTERCONNECTION 30A LOAD SIDE BREAKER IN EXTERIOR NEW METER-MAIN SERVICE PANEL WITH 200A MAIN BREAKER, 200A BUSBAR, 120/240V, 3W, 1ɸ UTILITY SCE AHJ SANTA ANA CITY REV_A : 11/04/2024 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg#:101121618 Elec#:20184505 Approvals: Elec: M Smith 5402 W Lehnhardt Ave11/25/2024 97 ' - 1 1 " 58' 98 ' - 9 " 60'-10" 16 ' - 2 " 3'-5" 4'-2" 3'-2" DC D IN V AC D BA T MS P M TRANG DO RESIDENCE 5402 W LEHNHARDT AVE., SANTA ANA, CA 92704 SIGNED & STAMP BY DATE 10/14/2024 PROJECT ID OPS 034-874 CREATED BY SS CHECKED BY RB SCALE SHEET SIZE 11"X 17" ANSI B #REVISION/UPDATE DATE B REVISION 11/04/2024 SHEET INFORMATIONHOMEOWNER INFO SHEET NO. APN NUMBER: 10859132 PV-1 PHONE NO: (714) 548-0899 Luxor Energy, Inc 11740 Sterling Ave, Riverside, CA 92503 C10 LICENSE Lic No. #1102673 www.myluxorenergy.com SITE PLAN PROPOSED SITE DIAGRAM SHOWING THE RELATIVE LOCATION OF MAJOR COMPONENTS. 1/12" = 1'-0" ROOF ACCESS POINT: ·ROOF ACCESS, PATHWAYS AND SPACING REQUIREMENTS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS 1205.2.1 THROUGH 1205.3.3. PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF. PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS, SUCH AS VENT PIPES, CONDUIT OR MECHANICAL EQUIPMENT. PROTECTION OF EMERGENCY RESPONDERS ALL SHARP EDGES AND FASTENER TIPS SHALL BE COVERED OR CRIMPED OVER TO ELIMINATE SHARP EDGES, TO MINIMIZE RISK OF INJURY TO EMERGENCY RESPONDERS. ALL ROOF MOUNTED CONDUITS, BOXES, AND EQUIPMENT CROSSING PATHWAYS ARE TO BE CLEARLY IDENTIFIED BY A RED/WHITE REFLECTIVE TAPE OR OTHER APPROVED MATERIAL. ROOF ACCESS POINT ROOF #2 (8)JINKO SOLAR JKM425N-54HL4-B MODULES CHIMNEY (N) PV NON FUSED AC DISCONNECT 2-STORY HOUSE (N)SOLAREDGE ENERGY HUB SE5700H-US INVERTER PV AC DISCONNECTACD LEGEND FENCE ROOF ACCESS POINT UTILITY METER MAIN SERVICE PANELMSP M INVERTERINV VENT, ATTIC FAN (ROOF OBSTRUCTIONS) PROPERTY LINE (E) PATIO (IT DOES NOT CONTAIN ANY ELECTRICAL EQUIPMENT) (E) DRIVEWAY SOLAREDGE ENERGY BANK BATTERY (10kW)BAT NOTES: BATTERY SHOULD BE INSTALLED 3FEET DISTANCE FROM ANY ENTERING DWELLING UNIT. W LEHNHARDT AVE. (N) SOLAREDGE ENERGY BANK BATTERY (10kW) (BAT-10K1PS0B-02) (N)200A MAIN SERVICE PANEL TIED WITH UTILITY METER (E) FENCE (N) ESS DC DISCONNECT ROOF #1 (7)JINKO SOLAR JKM425N-54HL4-B MODULES ESS DC DISCONNECTDCD (E) CHIMNEY REV_A : 11/04/2024 5402 W Lehnhardt Ave11/25/2024 DC D IN V AC D BA T MS P M JB 4' - 6 " 14 ' - 1 1 " 41 ' - 7 " 1'-11" 10'-9" 2'-4" 6" 17'-0" 3'-4" 1' - 1 1 " 10 ' - 6 " 1' - 6 " 6'-0" TYP. TRANG DO RESIDENCE 5402 W LEHNHARDT AVE., SANTA ANA, CA 92704 SIGNED & STAMP BY DATE 10/14/2024 PROJECT ID OPS 034-874 CREATED BY SS CHECKED BY RB SCALE SHEET SIZE 11"X 17" ANSI B #REVISION/UPDATE DATE B REVISION 11/04/2024 SHEET INFORMATIONHOMEOWNER INFO SHEET NO. APN NUMBER: 10859132 PV-2 PHONE NO: (714) 548-0899 Luxor Energy, Inc 11740 Sterling Ave, Riverside, CA 92503 C10 LICENSE Lic No. #1102673 www.myluxorenergy.com ROOF ATTACHMENT DETAILS NOTES: ATTACHMENT POINTS ARE NOT EXACT. CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATION. EXISTING ROOF CONDITION & RAFTER LOCATIONS ARE SUBJECT TO FIELD VERIFICATION. ACTUAL LOCATION MAY DIFFER. INSTALL PER MANUFACTURER SPECIFICATIONS. SEE SUPPLEMENTAL DOCUMENTS FOR ATTACHMENT & STRUCTURAL DOCUMENTATION. 1/10" = 1'-0" (N) JUNCTION BOX (36)IRONRIDGE QUICKMOUNT HALO ULTRAGRIP ROOF ATTACHMENT @72" O.C. ROOF ARRAY (15)JINKO SOLAR JKM425N-54HL4-B MODULES (15)SOLAREDGE POWER OPTIMIZER S500B IRONRIDGE XR-10 RAIL LEGEND VENT, ATTIC FAN (ROOF OBSTRUCTIONS) UTILITY METER MAIN SERVICE PANEL JUNCTION BOXJB MSP M SOLAREDGE POWER OPTIMIZER S500B CONDUIT INVERTERINV RAFTER PV AC DISCONNECTACD 18" FIRE SETBACKS ROOF OVERHANGING SIZE: MAX 18" RO O F # 1 ROOF #2 ROOF DETAILS MOUNTING PLANE ROOF #1 ROOF #2 NO. OF MODULES 7 8 AZIMUTH 178°268° ROOF TILT 20°18° ROOF TYPE COMP. SHINGLE COMP. SHINGLE RAFTER SIZE 2" X 6" 2" X 6" RAFTER SPACING 24" O.C 24" O.C ARRAY AREA 147.14 168.16 (TOTAL ARRAY AREA/ TOTAL ROOF AREA) X 100% = (315.29/3126.47) X 100% = 10.08%SOLAREDGE ENERGY BANK BATTERY (10kW)BAT NOTES: BATTERY SHOULD BE INSTALLED 3FEET DISTANCE FROM ANY ENTERING DWELLING UNIT.W LEHNHARDT AVE. FRONT OF RESIDENCE ESS DC DISCONNECTDCD MAXIMUM MOUNT SPACING: 6'-0" O.C. MOUNTING PATTERN SAMPLE MOUNT PATTERN: STAGGERED 6'-0" MAX ATTACHMENT SPACING IRONRIDGE QUICKMOUNT HALO ULTRAGRIP NOTES: ROOF ACCESS, PATHWAYS AND SPACING REQUIREMENTS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS 1205.2.1 THROUGH 1205.3.3. PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF. PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS, SUCH AS VENT PIPES, CONDUIT OR MECHANICAL EQUIPMENT. (N) EMT CONDUIT CHIMNEY (N) PV NON FUSED AC DISCONNECT (N)SOLAREDGE ENERGY HUB SE5700H-US INVERTER (N) SOLAREDGE ENERGY BANK BATTERY (10kW) (BAT-10K1PS0B-02) (N)200A MAIN SERVICE PANEL TIED WITH UTILITY METER (N) ESS DC DISCONNECT 18" FIRE SETBACKS 36" FIRE SETBACKS 36" FIRE SETBACKS 36 " F I R E S E T B A C K S 36 " F I R E S E T B A C K S 18 " F I R E S E T B A C K S 18 " F I R E S E T B A C K S BACK OF RESIDENCE REV_A : 11/04/2024 5402 W Lehnhardt Ave11/25/2024 TRANG DO RESIDENCE 5402 W LEHNHARDT AVE., SANTA ANA, CA 92704 SIGNED & STAMP BY DATE 10/14/2024 PROJECT ID OPS 034-874 CREATED BY SS CHECKED BY RB SCALE SHEET SIZE 11"X 17" ANSI B #REVISION/UPDATE DATE B REVISION 11/04/2024 SHEET INFORMATIONHOMEOWNER INFO SHEET NO. APN NUMBER: 10859132 S-1 PHONE NO: (714) 548-0899 Luxor Energy, Inc 11740 Sterling Ave, Riverside, CA 92503 C10 LICENSE Lic No. #1102673 www.myluxorenergy.com STRUCTURAL DETAILED DIAGRAM NTS NOTES: FLASHING SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURERS PRINTED INSTRUCTIONS. IF THERE IS ANY CONFLICT BETWEEN WHAT IS DEPICTED & INSTRUCTION AS PER MANUFACTURER, MANUFACTURERS INSTRUCTIONS SHALL SUPERSEDE. STRUCTURAL NOTES: 1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE IRONRIDGE XR-10 SYSTEM WITH IRONRIDGE QUICKMOUNT HALO ULTRAGRIP ATTACHMENTS. 2. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND MUST BE STAGGERED TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 3. THE PROPOSED PV SYSTEM ADDS 2.42 PSF TO THE ROOF FRAMING SYSTEM. 4. ROOF LIVE LOAD = 20 PSF 5. GROUND SNOW LOAD = 0 lb/sqft 6. WIND SPEED = 95 MPH 7. EXPOSURE CATEGORY = B 8. RISK CATEGORY = II ATTACHMENT DETAILED DIAGRAMSTRUCTURAL ELEVATION DIAGRAMSTRUCTURAL ELEVATION DIAGRAM (E) COMP SHINGLE ROOF 5" SEE FOR ENLARGED VIEW PV MODULE 2" X 6" RAFTER @24" O.C. RD STRUCTURAL SCREW (PN RD-1430-01-M1) IRONRIDGE XR-10 RAIL (E)COMP. SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRAGRIP PV MODULE 2" X 6" RAFTER @24" O.C. 2-1/2" LAG SCREW MINIMUM EMBEDMENT 5402 W Lehnhardt Ave11/25/2024 GRADE EAST WALL ELEVATION (N) METER-MAIN SERVICE PANEL FROM JUNCTION BOX (N) AC DISCONNECT SOLAR EDGE (N) SOLAREDGE ENERGY HUB SE5700H-US (N) ESS DC DISCONNECT FROM UTILITY GRID M CHIMNEY GAS METER SOLAREDGE (N) SOLAREDGE ENERGY BANK 10 KW BATTERY (BAT-10K1PS0B-02) TOWARDS PV AC DISCONNECT TOWARDS INVERTER MIN 3'MIN 3'MAX 6' TRANG DO RESIDENCE 5402 W LEHNHARDT AVE., SANTA ANA, CA 92704 SIGNED & STAMP BY DATE 10/14/2024 PROJECT ID OPS 034-874 CREATED BY SS CHECKED BY RB SCALE SHEET SIZE 11"X 17" ANSI B #REVISION/UPDATE DATE B REVISION 11/04/2024 SHEET INFORMATIONHOMEOWNER INFO SHEET NO. APN NUMBER: 10859132 S-2 PHONE NO: (714) 548-0899 Luxor Energy, Inc 11740 Sterling Ave, Riverside, CA 92503 C10 LICENSE Lic No. #1102673 www.myluxorenergy.com EQUIPMENT ELEVATION DIAGRAM NTS NOTES: ESS UNIT LOCATION(S) AND DISTANCES RELATIVE TO ONE ANOTHER AND TO ALL RELEVANT BUILDING FEATURES AND OTHER EQUIPMENT, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (2020 LACFC §1206.4.2.1, §1206.4.3.1) I.) INDIVIDUAL ESS UNITS SHALL BE SEPARATED FROM ONE ANOTHER BY 3 FEET. II.) WHERE AN ESS IS INSTALLED ON AN EXTERIOR WALL OR OUTDOOR, ESS UNITS SHALL BE SEPARATED FROM ALL WINDOWS, DOORS, OPERABLE OPENINGS AND HVAC INLETS BY 3 FEET (IN ANY DIRECTION). EQUIPMENT ELEVATION DIAGRAM REV_A : 11/04/2024 5402 W Lehnhardt Ave11/25/2024 November 06, 2024 Subject: Proposed Solar Panel Installation Trang Do Residence, 5402 W Lehnhardt, Santa Ana, CA To Whom it May Concern, Design Parameter Summary Governing Building Code: 2022 California Residential Code Risk Category: II Wind Exposure: C Design Wind Speed: 110 mph Ground Snow Load: 10 psf Roof Information Roofing Material: Asphalt Shingles Roof Slope: 18, 20 degrees We have reviewed information, provided by our client, related to the proposed solar panel installation at the above-referenced address. The purpose of the review was to determine if the existing roof is structurally adequate for the proposed installation. Based on our review and analysis of the given information, and in accordance with governing building codes, I certify that the capacity of the structural roof framing that directly supports the additional gravity loading due to the solar panel supports and modules had been reviewed and determined to meet or exceed the requirements in accordance with the Design Criteria. Engineering Analysis Framing Mount Wood Screws: (2) #14 Self-Drilling Screw with a minimum penetration depth of 2.5" into rafter only, at 72" O.C. max Roof Structure: 2x6 Rafters @ 24" O.C. (assumed) Roof Connection Details Wind uplift on the panels has been calculated in accordance with the relevant provisions of ASCE 7-22. This loading has been used to verify the adequacy of the connection specified above. Connection locations should be in accordance with design drawings. Stagger attachments to avoid overloading any individual rafter. The proposed installation will be 5" max. above the roof surface (flush mounted) and parallel to the roof surface. Therefore, any increase in wind loading on the building structure from the solar panel installation is expected to be negligible. Wind is the governing lateral load case. Because the increase in lateral loading is not increased by more than 10%, per provisions in the adopted building codes, the structure need not be altered for lateral loading. IronRidge XR10 rails will support the modules and will fasten to the roof structure with IronRidge QuickMount Halo Ultragrip along the rail. The proposed installation - including weight of panels, racking, mounts, and inverters where applicable - will be approximately 3 psf. In the areas where panels are installed, roof live loads will not be present. The reduction of roof live load is adequate to fully or partially compensate for the addition of the panel installation. Because the member forces in the area of the solar panels are not increased by more than 5%, and so per provisions in the adopted building codes, the structure need not be altered for gravity loading. The roof structure need not be altered for either gravity loading (including snow) or lateral loading (including wind). Therefore, the existing structure is permitted to remain unaltered. Connections to the roof must be made per the "Roof Connection Details" section above. Copies of all relevant calculations are enclosed. Conclusion 5402 W Lehnhardt Ave11/25/2024 Sincerely, Trevor A. Jones, P.E. 11/6/2024 Limitations and Disclaimers Electrical design is excluded from this analysis. Waterproofing is the sole responsibility of the installer and is also excluded from this analysis. Solar panels must be installed per manufacturer specifications. Structural design and analysis of the adequacy of solar panels, racks, mounts, and other components is performed by each component's respective manufacturer; the undersigned makes no statement authority (city or county building department) and your office, and may not be utilized or relied on by any other party. The opinion expressed in this letter is made in reliance on the following assumptions: the existing structure is in good condition; the existing structure is free from defects in design or workmanship; and the existing structure was code‐compliant at the time of its design and construction. These assumptions have not been independently verified, and we have relied on representations made by our client with respect to the foregoing. The undersigned has not inspected the structure for defects, although we have reviewed the information provided by our client, including pictures where applicable. 5402 W Lehnhardt Ave11/25/2024 Standard Loading Comparison Without Solar With Solar Dead Load Asphalt Shingles 5 5 psf 1/4" Plywood 1 1 psf Framing 2 2 psf Insulation ---- psf 1/2" Gypsum Ceiling ---- psf M,E, & Misc ---- psf Solar Panel 0 3 psf Total Dead Load 8 11 psf Snow Load Ground Snow Load, Pg psf Exposure Factor, Ce Thermal Factor, Ct Importance Factor, Is Flat Roof Snow Load ASCE 7 Eqn. 7.3-1 or jurisdiction min. Slope degrees Unobstructed Slippery Surface?No No Slope Factor, Cs 1.00 1.00 Sloped Roof Snow Load 7.7 7.7 psf Live Load Roof Live Load 20 0 psf Load Combination D + Lr 28.0 11.0 psf D + S 15.7 18.7 psf Max. Load 28.0 18.7 psf % of original 66.79% Result: This calculation justifies the additional solar load by comparing existing to proposed gravity loads in the location of the solar panels. Because the total forces are decreased, per the relevant code provisions stated in the body of the letter, the existing roof structure is permitted to remain unaltered. 10 1.1 18 1 1.00 8 5402 W Lehnhardt Ave11/25/2024 Wood Screw Calculation (per ASCE 7-22) Connection Demand Spacing perpendicular to rail, in 34 Roof Angle, degrees 18 Roof Layout Gable Wind Speed, mph 110 z 0.95 (Table 26.10-1) zt 1.00 (Table 26.8.1) d 0.85 (Table 26.6-1) e 1.00 (Table 26.9-1) z, psf 24.8 (Table26.10-1) Zones:1 2n, 2r, 2e 3r, 3e Spacing parallel to rail, in 72 72 72 p (max)(Figure 29.4-7)2.00 2.67 3.19 E = 1.5) (Fig. 29.4-7)No No No Effective Wind Area on each con., ft2 17.0 17.0 17.0 a (Figure 29.4-8)0.71 0.71 0.71 Uplift Force, psf (Equation 29.4-7)35.1 46.9 56.0 Max. Uplift Force / Connection (0.6 WL), lbs 358.4 478.5 570.7 Solar Dead Load (0.6 DL). Lbs 30.6 30.6 30.6 Max. Uplift Force (0.6 WL - 0.6 DL), lbs 327.8 447.9 540.1 Connection Capacity Attachment FTG IronRidge QuickMount Halo Ultragrip Attachment location Framing Fastener Type Wood Screw Fastener Diameter, in 0.242 Embedment Length, in 2.5 Lumber Species & Grade DFL #2 (Assumed) Nominal Withdrawal Capacity W, lbs 431 # of Screws 2 d 1.6 Screw Adj. Withdrawal Cap. W', lbs 1379 Attachment FTG Strength with Cd, lbs 1606 Max applied load, lbs 540 Max allowable load, lbs 1379 Compare Adjusted Withdrawal Capacity to ASD Factored Demand Zones:1 2n, 2r, 2e 3r, 3e O.K. O.K. O.K. This calculation justifies the connection of the solar panels to existing roof members, by showing the connection capacity is equal to or greater than the uplift force demands. 5402 W Lehnhardt Ave11/25/2024 Seismic Load Increase Check Seismic Design Parameters Site Class D (Default)Risk Cat.II Ss 1.68 3 S1 0.592 e (Table 1.5-2)1 SDS (Equation 11.4-3)1.12 Fa (Table 11.4-1) 1 SD1 (Equation 11.4-4)0.592 v (Table 11.4-2)1.5 Cs (Equation 12.8-2)0.373 Seismic Design Category D Seismic Weight - No Panels Roof Self Weight, psf 8 Roof Area, ft2 3126 Wall Dead Load, psf 8 Wall Height (estimated), ft 20 Roof Perimeter, ft 120 ft Seismic Weight 12.9 kips Panel Seismic Weight Panel Weight 3 psf # of Panels 15 Panel Area 315.3 ft^2 Seismic Weight Increase 0.4 kips % increase 3% Result The purpose of this calculation is to verify that seismic weight - and therefore seismic force, and therefore total lateral load - is not increased by more than 10%. Therefore, per provisions in the adopted building codes, the structure need not be altered for lateral loading. Seismic weight is not increased by more than 10%, and so structure need not be altered for lateral loading. 5402 W Lehnhardt Ave11/25/2024 = ~ DC- DC- DC+DC+ DC DISCONNECT DC- DC+ MANUAL BYPASS N.O.N.C.AC DISCONNECT N.C.N.O. L1 L2 L1 L2 L1 L2 AUTOMATIC SWITCHOVER CIRCUIT BREAKER FUSES L1 L2 G N L2 L1 L2 L1 (N) AC DISCONNECT, 30A NON-FUSED, LOCKABLE, 120/240V, 2P, NEMA 3R, UL-LISTED FE (N)SOLAREDGE ENERGY HUB SE5700H-US INVERTER 99% CEC EFFICIENCY @ 240VAC 5760WAC CONTINOUS MAXIMUM OUTPUT CURRENT 24A GROUND-FAULT PROTECTION PROVIDED PER CEC ARTICLE 690.35 (N) JUNCTION BOX: 600V, NEMA 3R, UL LISTED (READILY ACCESSIBLE) - + -++ - + ++ +-- - - + - = = = = = = = = = = (15)JINKO SOLAR JKM425N-54HL4-B MODULES STRING 1 OF 08 MODULES STRING 2 OF 07 MODULES - + -++ - + ++ +-- - - + - 1 = = = = = = = = = = - + - + - + - + 2 3 7 1 2 3 - - = - - = SolarEdge Power Optimizer S500B Rated DC Input Power - 500 watts Maximum Input Voltage - 125 Vdc MPPT Range - 12.5 to 105 Vdc Maximum Input Current - 15 Adc Maximum Output Current - 15 Adc String Limitations - 6 to 25 Optimizers, 5700 watts STC per string maximum B A SOLAREDGE ENERGY BANK 10 KW BATTERY, 350V LITHIUM BATTERY +- (N) SOLAREDGE ENERGY BANK 10 KW BATTERY (BAT-10K1PS0B-02) D L2L1 L2L1 (N) ESS DC DISCONNECT, 30A,LOCKABLE, 600V, NEMA 3R, UL LISTED C G 8 6 7 6' MAX POINT OF INTERCONNECTION, 30A LOAD SIDE BREAKER EXISTING GROUNDING ELECTRODE CONDUCTOR MM TO UTILITY GRID (N) 200A/2P BI-DIRECTIONAL UTILITY METER #222013-150780 1-PH, 3-W, 120V/240V UTILITY COMPANY - SCE (N) 200A EXTERIOR METER-MAIN SERVICE PANEL UPGRADED FROM (E) 200A RATED, 1-PH, 3-W, 240V (N)200A/2P MAIN BREAKER UPGRADED FROM (E) 200A MAIN BREAKER TO HOUSE, 240V 20A/2P 30A/2P 30A/2P 20A/2P FAU FRIDGE 20A/2P 20A/2P EV CHARGER AC GARAGE LIGHTS 20A/2P LIGHTS 20A/2P ROOM LIVING ROOM 20A/2P KITCHEN 50A/2P 50A/2P 20A/2P 20A/2P20A/2P (N) 20A/2P FISHPOND OVEN UPSTAIRLIGHTS 20A/2P KITCHEN (N) 30A/2P SURGE PROTECTION DEVICE TRANG DO RESIDENCE 5402 W LEHNHARDT AVE., SANTA ANA, CA 92704 SIGNED & STAMP BY DATE 10/14/2024 PROJECT ID OPS 034-874 CREATED BY SS CHECKED BY RB SCALE SHEET SIZE 11"X 17" ANSI B #REVISION/UPDATE DATE B REVISION 11/04/2024 SHEET INFORMATIONHOMEOWNER INFO SHEET NO. APN NUMBER: 10859132 E-1 PHONE NO: (714) 548-0899 Luxor Energy, Inc 11740 Sterling Ave, Riverside, CA 92503 C10 LICENSE Lic No. #1102673 www.myluxorenergy.com ELECTRICAL DIAGRAM & CALCULATIONS NTS 120% RULE CEC 705.12 (B)(2)(3)(b) (BUS BAR RATING X 120%) - MAIN BREAKER RATING = MAX. PV OCPD (200A x 120%) - 200A = 40A INSTALLED PV BREAKER = 30A SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL JINKO SOLAR JKM425N-54HL4-B VMP 32.37V IMP 13.13A VOC 38.95V ISC 13.58A TEMP. COEFF. VOC -0.25 %/°C MODULE DIMENSION 67.79" (L) x 44.65" (W) PANEL WATTAGE 425W EQUIPMENT DETAILS (#) PV MODULES (15)JINKO SOLAR JKM425N-54HL4-B (#) OPTIMIZERS (15)SOLAREDGE POWER OPTIMIZER S500B (#) INVERTER (1)SOLAREDGE ENERGY HUB SE5700H-US (#)BATTERY (01) SOLAREDGE ENERGY BANK BATTERY (10KW) (BAT-10K1PS0B-02) SYSTEM OUTPUT CURRENT 24.00A STRING 1 STRING OF 08 MODULES & 1 STRING OF 07 MODULES POINT OF INTERCONNECTION 30A LOAD SIDE BREAKER IN EXTERIOR NEW METER-MAIN SERVICE PANEL WITH 200A MAIN BREAKER, 200A BUSBAR, 120/240V, 3W, 1ɸ UTILITY SCE AHJ SANTA ANA CITY PV SYSTEM DETAILS [ DC ] SYSTEM SIZE [ AC ] SYSTEM SIZE (15) MODULES x 425W (1) INVERTER x 5760W 6.375 kW 5.760 kW NOTE: NONE OF THE BACKUP LOAD CIRCUIT EXCEEDS THE MAXIMUM ESS SOURCE OF CURRENT. NOTE: IT IS ASSUMED THAT THE CONDUIT OR RACEWAY CONTAINING THE RELOCATED LOADS CONDUCTORS IS 24" OR LESS IN LENGTH. IF NOT, THEN THE CONDUCTORS MUST BE ADJUSTED FOR AMPACITY DUE TO THE NUMBER OF CURRENT-CARRYING CONDUCTORS IN CONDUIT. 2022 CALIFORNIA ELECTRICAL CODE (CEC) TABLE 310.15(C)(1), TABLE 310.16 NOTE: ANY CIRCUITS EXTENDED BY MORE THAN 6 FEET IN A RACEWAY MUST FOLLOW THE CURRENT AFCI REQUIREMENTS OF CEC 210.12. NOTES: BATTERY SHOULD BE INSTALLED 3FEET DISTANCE FROM ANY ENTERING DWELLING UNIT. REV_A : 11/04/2024 5402 W Lehnhardt Ave11/25/2024 TRANG DO RESIDENCE 5402 W LEHNHARDT AVE., SANTA ANA, CA 92704 SIGNED & STAMP BY DATE 10/14/2024 PROJECT ID OPS 034-874 CREATED BY SS CHECKED BY RB SCALE SHEET SIZE 11"X 17" ANSI B #REVISION/UPDATE DATE B REVISION 11/04/2024 SHEET INFORMATIONHOMEOWNER INFO SHEET NO. APN NUMBER: 10859132 E-2 PHONE NO: (714) 548-0899 Luxor Energy, Inc 11740 Sterling Ave, Riverside, CA 92503 C10 LICENSE Lic No. #1102673 www.myluxorenergy.com ELECTRICAL DIAGRAM & CALCULATIONS NTS BATTERY SPECIFICATION MODEL SOLAREDGE ENERGY BANK BATTERY (10KW)(BAT-10K1PS0B-02) AMBIENT TEMPERATURE RANGE -10°C TO 50°C VOLTAGE RANGE 350-450 VDC USABLE CAPACITY 9.7 KWH INTERCONNECTION SINGLE-PHASE AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 2°C AMBIENT TEMP (HIGH TEMP 2%)31°C CONDUIT HEIGHT 7/8" ROOF TOP TEMP 90°C CONDUCTOR TEMPERATURE RATE 53°C MODULE TEMPERATURE COEFFICIENT OF VOC -0.25 %/°C INVERTER SPECIFICATIONS MANUFACTURER / MODEL SOLAREDGE ENERGY HUB SE5700H-US NOMINAL OUTPUT VOLTAGE 240VAC CONTINUOUS OUTPUT CURRENT 24A ID CONDUCTOR CONDUIT # OF PARALLEL CIRCUITS CURRENT-CARRYING CONDUCTORS IN CONDUIT CONDUIT FILL PERCENT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT (INVERTER CONTINUOUS CURRENT x 1.25) MAX CURRENT BASE AMP.DERATED AMP.LENGTH VOLTAGE DROP A 10 AWG PV WIRE OPEN AIR 1 2 N/A N/A 6 AWG BARE COPPER 0.76 (53°C)N/A 15A x 1.25 = 18.8A N/A N/A 76FT 0.03% B 10 AWG THWN-2 COPPER MIN 0.75" Dia EMT 2 4 19.09%N/A 8 AWG THWN-2, COPPER 0.96 (31°C)0.8 15A x 1.25 = 18.8A 35A 35A x 0.8 x 0.96 = 26.9A 37FT 0.12% C 10 AWG THWN-2 COPPER MIN 0.75" Dia EMT 1 2 11.45%N/A 8 AWG THWN-2, COPPER 0.96 (31°C)1 14.3A x 1.25 =17.9A 35A 35A x 1 x 0.96 = 33.6A 5FT 0.08% D 10 AWG THWN-2 COPPER MIN 0.75" Dia EMT 1 2 11.45%N/A 8 AWG THWN-2, COPPER 0.96 (31°C)1 14.3A x 1.25 =17.9A 35A 35A x 1 x 0.96 = 33.6A 5FT 0.08% E 10 AWG THWN-2 COPPER MIN 0.75" Dia EMT 1 3 15.27%N/A 8 AWG THWN-2, COPPER 0.96 (31°C)1 24.0A x 1.25 =30.0A 35A 35A x 1 x 0.96 = 33.6A 35FT 0.92% F 10 AWG THWN-2 COPPER MIN 0.75" Dia EMT 1 3 15.27% 30A 8 AWG THWN-2, COPPER 0.96 (31°C)1 24.0A x 1.25 =30.0A 35A 35A x 1 x 0.96 = 33.6A 5FT 0.13% 5402 W Lehnhardt Ave11/25/2024 TRANG DO RESIDENCE 5402 W LEHNHARDT AVE., SANTA ANA, CA 92704 SIGNED & STAMP BY DATE 10/14/2024 PROJECT ID OPS 034-874 CREATED BY SS CHECKED BY RB SCALE SHEET SIZE 11"X 17" ANSI B #REVISION/UPDATE DATE B REVISION 11/04/2024 SHEET INFORMATIONHOMEOWNER INFO SHEET NO. APN NUMBER: 10859132 E-3 PHONE NO: (714) 548-0899 Luxor Energy, Inc 11740 Sterling Ave, Riverside, CA 92503 C10 LICENSE Lic No. #1102673 www.myluxorenergy.com POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN. CAUTION! LABEL LOCATION: EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONCECTED NTS PLACARDS 1 2 3 4 5 6 7 ADHESIVE FASTENED SIGNS: ·LABELS SHALL BE MADE OF RED PLASTIC MATERIAL WITH ENGRAVED WHITE LETTERS. ·LETTERS SHALL BE A MINIMUM 3/8" IN SIZE. ·THE LABELS SHALL BE PERMANENTLY ATTACHED TO THE APPROPRIATE PANEL. ·AC & DC CONDUIT, RACEWAY, ENCLOSURES, CABLE ASSEMBLIES AND JUNCTION BOXES SHALL BE RED BACKGROUND MATERIAL WITH WHITE LETTERING MADE OF DURABLE ADHESIVE, REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT PER UL 969; TO ALERT FIRE SERVICE TO AVOID CUTTING THEM OFF. LABEL LOCATION: MAIN SERVICE PANEL/AC DISCONNECT 2022 CEC 690.53 RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: INVERTER AT OR WITHIN 3' OF THE DC COMBINER SWITCH 2022 CEC 690.56(C)(3) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT 2022 CEC 690.54 PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH LABEL LOCATION: MAIN SERVICE PANEL IF MSD IS OUTSIDE PLACE IT THERE / IF MSD IS INSIDE PLACE ON THE AC DISCONNECT 2022 CEC 690.56(C) WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: MAIN SERVICE PANEL/AC DISCONNECT/INVERTER/ AC COMBINER 2022 CEC 690.13(B) 24.00A 240 VAC ! WARNING ELECTRIC SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF APPLICABLE). PER CODE(S): CEC 2022: 690.5(C) ! PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: MAIN SERVICE PANEL 2022 CEC 705.12(B)(2)(3)(c) 8 MAXIMUM VOLTAGE: 480 VDC MAXIMUM CIRCUIT CURRENT: 15 ADC MAX. RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC-CONVERTER (IF 30 ADC INSTALLED) LABEL LOCATION: INVERTER PER 2022 CEC 690.53 FIRST SOURCE IS UTILITY ELECTRICAL GRID SECOND SOURCE IS AC BATTERY THIRD SOURCE IS PV INVERTER LABEL LOCATION: SUB PANEL OR BACKUP LOADS PANEL, BATTERY, INVERTER OUTPUT PANEL, MAIN SERVICE PANEL, METER/MAIN AND PV AC DISCONNECT 2022 CEC 705.10 CAUTION - TRI POWER SOURCE 9 BATTERY DISCONNECT DO NOT RELOCATE THIS OVERCURRENT DEVICE REQ'D BY: CEC 706.15(C) LABEL LOCATION: BATTERY BREAKERS 10 BATTERY METER-MAIN SERVICE DISCONNECT INVERTER ESS DC DISCONNECT W L E H N H A R D T A V E . PV AC DISCONNECT DCDINVACD BATMSPM ROOFTOP PV ARRAYS 5402 W Lehnhardt Ave11/25/2024 DC D IN V AC D BA T MS P M JB TRANG DO RESIDENCE 5402 W LEHNHARDT AVE., SANTA ANA, CA 92704 SIGNED & STAMP BY DATE 10/14/2024 PROJECT ID OPS 034-874 CREATED BY SS CHECKED BY RB SCALE SHEET SIZE 11"X 17" ANSI B #REVISION/UPDATE DATE B REVISION 11/04/2024 SHEET INFORMATIONHOMEOWNER INFO SHEET NO. APN NUMBER: 10859132 PV-3 PHONE NO: (714) 548-0899 Luxor Energy, Inc 11740 Sterling Ave, Riverside, CA 92503 C10 LICENSE Lic No. #1102673 www.myluxorenergy.com BOM & STRING LAYOUT 1/10" = 1'-0" STRING LEGEND STRING #1 - 08 MODULESA ARRAY WEIGHT (LOAD CALC'S) Number of Modules 15 Module Weight 48.5 LBS Total Module (Array) Weight 727.50 LBS Number of Attachment point 36 Mounting System Weight (Per Module)1 LBS Mounting System Weight 36.00 LBS Total System Weight (Module Weight + Mounting System Weight)763.50 LBS Weight at Each Attachment Point (Array Weight / Number of Attachment Point) 20.21 LBS Module Area (67.79"x44.65")21.02 SqFt Total Array Area 315.29 SqFt Distributed Load (Total System Weight / Total Array Area)2.42 Per SqFt Total Roof Area 3126.47 SqFt Total Percentage of Roof Covered Total Array Area / Total Roof Area)*100 10.08% B-1 JB MSP M INV LEGEND UTILITY METER MAIN SERVICE PANEL JUNCTION BOX VENT, ATTIC FAN (ROOF OBSTRUCTIONS) INVERTER EMT CONDUIT PV AC DISCONNECTACD BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 15 JINKO SOLAR JKM425N-54HL4-B MODULES OPTIMIZER 15 SOLAREDGE POWER OPTIMIZER S500B INVERTER 1 SOLAREDGE ENERGY HUB SE5700H-US INVERTER JUNCTION BOX 1 JUNCTION BOX, 600V, NEMA 3R, UL LISTED PV AC DISCONNECT 1 30A NON-FUSED PV AC DISCONNECT, LOCKABLE, 120/240V, 2P, NEMA 3R ESS DC DISCONNECT 1 30A ESS DC DISCONNECT, LOCKABLE, 600V, 3P, NEMA 3R BATTERY 1 SOLAREDGE ENERGY BANK BATTERY (10kW) (BAT-10K1PS0B-02) ATTACHMENT 36 IRONRIDGE QUICKMOUNT HALO ULTRAGRIP ATTACHMENT 72 RD STRUCTURAL SCREW (PN RD-1430-01-M1) ATTACHMENT 36 WASHER, EPDM BACKED RAIL 12 IRONRIDGE XR-10 RAIL (168") BONDED SPLICE 8 BONDED SPLICE CLAMPS 40 UNIVERSAL FASTENING OBJECTS (UFO) CLAMPS 20 STOPPER SLEEVE GROUNDING LUG 5 GROUNDING LUG FRONT OF RESIDENCE W LEHNHARDT AVE. NOTES: BATTERY SHOULD BE INSTALLED 3FEET DISTANCE FROM ANY ENTERING DWELLING UNIT. SOLAREDGE ENERGY BANK BATTERY (10kW)BAT ESS DC DISCONNECTDCD CHIMNEY B-7 A-1A-8 STRING #2 - 07 MODULESB BACK OF RESIDENCE 5402 W Lehnhardt Ave11/25/2024 www.jinkosolar.com Tiger Neo N-type 54HL4-B 425 Watt ALL-BLACK MODULE N-Type Positive power tolerance of 0~+3% IEC61215 (2016), IEC61730 (2016) IS09001:2015: Quality Management System IS014001: 2015: Environment Management Sys tern IS045001: 2018 Occupational heal th and safety management systems Key Features Slv!BB Technology Better light trapping and current collection to improve module power output and reliability. PID Resistance Excellent Anti-PIO performance guara ntee via optimized mass-production process and materials control. Durability Against Extreme Environmental Conditions lligh salt mist and ammonia resistance. HH � � 5400 Pa Hot 2.0 Technology • Solale J1nl<O Building Your Trust in Solar The N-type module with Hot 2. 0 technology has better reliability and lower LID/LETID. Enhanced Mechanical Load Certified to withstand: wind load (2400 Pascal ) and snow load (5400 Pascal). CE CLEAN ENERGY COUNCIL MEMBER POSITIVE QUALITY "' ConlhxK>oO....M�""'""""",. LINEAR PERFORMANCE WARRANTY 25 Year Product Wa rranty 30 Year Linear Power Warranty 0.40% Annual Degradation Over 30 years25 30 Engineering Drawings Elec trical Perfonnance & l'emperature Dependence CurrenL-Voltage & Power-Voltage Curves ( 415W) Tempen1.iure Dependence of lsc, Voe, Pmt1x □ 10 15 20 25 30 36 "' 180 180 :§: 140 J 120 20 ,..__ , .... lsc .......... Voe max Pront S:ile Back -50 -25 0 25 50 75 100 \'olt!!.ge (V) Cell TmpEITT!.ture ('C) Length:±� iidth: ±2• Height: ±1 ... Ros-Pitch; ± 2mm Mec hanical Charac teristics A-A Packaging Configuration ( Two pullets = One stack) 36pcs,/pnllets, 72pcs/stnck, 936pcs/ -1-0'HQ Cnntnirwr Module Type Maximum Power (Prnax) \1aximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voe) Short-circuit Current (Jsc) \1odule Efficiency STC (%) Operating Temperature ( °C) \1axillllllll syslt'III voltagt' Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voe Temperature coefficients of Tse Cell Type \Jo. of cells Dimensions Front Glass Frame Junction Uox Output Cah!Ps JKM425N-54HL4-B STC �OCT 425Wp 320Wp 32. 37V 30. 191 13.13A 10. 60A 38. 95V 37. 001 13. 58A lO. 96A 21. 76% -40"C-+85 °C 1000\'IIC ( I EC) 25A o-+3% -0. 29%/'C 0. 045%/°C X type Mono-crystalline 108 (6X 18) 1722Xll34X30nm, (67. 79X44.65Xl. 18 inch) 22 kg I 48. SO 1 hs) 3. 2mrn,Anti-Reflection Coating, High Transmission, Low Iron, Tempered Glass .\nodized Aluminium .\lloy 1 P68 Rated ll'V l X 4. 0mm (+): 400mn, (-): 200mm or Customized l,('ngth \ominal operating cell temperature (>JOCT) L ___ 1_5±_3°_c _ _ _J *STC : •= Irradiance lOOOW/m 2 Ill Cell Temperature 25 ° C NOCT: -1ifl0 : Irradiance 800W/m 2 ., .. II]AmbienL Temperalure 20 ° C 02021 Jinko Solar Co., Ltd. All rights reserved. Specifications included in this datasheet are subject to change without notice. Wind Speed lrn/s JKM425N-54HL4-B-F3C2-EN (IEC 2016) PAGE 10 5402 W Lehnhardt Ave11/25/2024 SolarEdge Home Hub Inverter Single Phase, for North America :::c: 0 For Inverters Assembled in the USA �SE3800H-US /[�}�0]H�U�/ SE7600H-US / SE10000H-US / SE11400H-US m 0 0 0 0 0 0 0 0 • • 0, )> n �C -c Single phase inverter for storage and backup applications I The ultimate home energy manager in charge of PV production, battery storage, backup operation during a power outage•, EV Charging, and smart energy devices I Record-breaking 99% weighted efficiency with up to 300% DC oversizing / Supports LRA -can provide the required energy for HVAC systems starting during backup operation I Integrates seamlessly with the complete SolarEdge Home Smart Energy Ecosystem, through SolarEdge Home Network I Module-level monitoring and visibility of battery status, PV production, and self consumption data •Require additional hardware ood firmware version upgrade. I Fast and easy installation -small and lightweight, with reduced commissioning time / A scalable solution that supports future homeowner needs through easy connection to a growing ecosystem of products I Advanced safety features with integrated arc fault protection and rapid shutdown for 690.11 and 690.12 I Advanced reliability with automotive-grade components I Embedded revenue grade production data, ANSI C 12.20 Class 0.5 / IP65-rated, for indoor and outdoor installations solartsT!tdi' I SolarEdge Home Hub Inverter Single Ph¥e,_ f.or�rth America SE3800H-US / e_E��H--=.U.§ / SE7600H-US / SE10000H-US / SE11400H-US Model Number 11• SE3800H US SE5700H US SE7600H US SE10000H US SE11400H US Umts OUTPUT -AC ON GRID Rated AC Power Maximum AC Power Output AC Output Voltage (Nominal) AC Output Voltage (Range) AC Frequency Range (min• nom -max) Maximum Continurus Output Current GFDI Threshok:l Total Harmonic Distortion (THO) Powe.-Factor Utility Monitoring, Islanding Protection, Country Configurable Thresholds Charge Battery from AC (if alkiwed) Typical Nighttime POHer Consumption OUTPUT-AC STAND-ALONE (BACKUP)''"" Rated AC Po..ver in Stand-alone OperatOn Maximum Stand-alme Capacity AC L-L Output Voltage Range in Stand-alone Operation AC L-N Output Voltage Ra,ge in Stand-alooe Operatioo AC Frequency Range in Stand-alone (min• nom -max) Maximum CootinUOJs Output Current in Stand-alone Operntion GFDI THO OUTPUT -SOLAREDGE HOME EV CHARGER AC Rated AC Power AC Output Voltage Range On-Grid AC Frequency Range (min -nom max) Maximum Cootinuws Output Current @Z40V (arid, PV and batterv) INPUT -DC (PV AND BATTERY) Transformer-less, Ungrounded Max Input Voltage Norn IX Input Voltage Reverse-Polarity Protectioo Ground-Fault Isolation Detection INPUT-DC (PV) Maximum DC Power @ 240V Maximum DC Power@ 208V Maximum Input Currentrn@ 240V Maximum Input Currentm@ 208V Maximum Input Short Circuit Current Maximum Inverter Efficiency CEC Weighted Efficiency 2-pole Disconnection 3800@ 240V I 3300@ 208V 3800@ 240V I 3300@ 208V 16 I 11,400 I 6600 I 20 I 17.S I 98.S 5760@240V I 7600 I 10000 5000@ 208V 5760 @240V I 7600 I 10000 5000@ 208V 208/240 183-264 59.3-60-505m 24 I 32 I 42 1 <3 1,adju�t:Ae -0.85 to 0.85 Yes Yes < 2.5 11,400161 11.400 211-264 105-132 55-60-65 48 1 <5 9600 211-264 59.3 -60 -60.5 40 Yes 480 380 Yes 6001:0Sensitivity 11,S20 I lS,200 I 20,000 10,000 I I 30.5 I 40 I 53 27 I I 45 99.2 I 99 Yes (1) These specifications apply to inv€rters v.ith part numbers SElo:xxH-USMNUxxxS arx:f SE>XO:H-USMNFxxxS and connection unit model number DCO-lPH-US-PxH+>t 111,400@ 240V 10,000@ 208V 111.400 @240V 10,000@ 208V I 48 I 22,BOO I 20,000 I 60 I 53 I 99@ 240V 98.5@2CR,V (2)ln,..,,rte1s wrth part number SExxxxH-USMNflOOD are intended foi ui:grade instaH.Jtionsonly, as part of the "Re-Energize" progr1m. Use on non-upgrade installations will revoke the prodJct w,1rra1ty. (3) fer other region.'11 settings please refc!r to the Snlarfdge lmrr:mrs PnllA"rCQntrd Options Appliglrinn r::+ore (4) � designed for non-g-id connected c1pplications 111d req_iires AC for commissioning. St<1r1d·alone (backup) functiontllity is onty supported for the 240V grid. (5) Fcr-LRA (Lo::kOO Rotor Amperage) >Jalues �e.ise refer to the LAA for NAM Anpli@) M NS!e-(6)fcr-models SVOOOH-US and below, the rated AC srand-alone p:iwer is configurable between 760(N.I or 11,4-00W !rem CPU version 4.20.:o:. (7) A higher current source may be used. The inverter will limit its input current to the values stated. Cl SolarE�TeclVlolog""'-Ltd. All ,ighl, r""""""1 SOLAFl£0Gf. the SotalEdgel ogQOl>TMIZEO 8Y SOIAFl£DGE ..-etradem.:ri:sOf regL.Steredtrademuksol" SolarlidgeTe::hnologoe,;. Inc . Al other tr.-.demarks mentioned herein ,nu;,,iemarks ol1heir respecli�owners. Cate: Febr\ay19,2m40S.(J(I0229-NAM. Subjecltoc�ange wilhoUI nO!ia. w w Vac Vac H, A A % w w w Vac Vac "' A A % w Aac Vdc Vdc w w Ade Ade Ade % % I SolarEdge Home Hub Inverter Single Phase, for North America SE3800H-US /i5ES?OOH-=-U�/ SE7600H-US / SE10000H-US / SE11400H-US [}h�•a111w11w 11Hih◄iilii111wa:;w IHiiiff I 1, SE3800H US OUTPUT -DC (BATTERY) Supported Battery Types Number of Batteries per lnv€'fter Continuous Power8l 11,400@240V 3800@200V Peak Pow@rS) 11,400@240V 3800@200V Maximum lnout Current 2-pole Disconnection SMART ENERGY CAPABILITIES Consumption Metering SolarEdge Home Battery, LG RESU Prime Up to 3 SolarEdge Home Battery, up to 2 LG RESU Prime I 11.400@240V I 11400@240V 111400 @240V 5000@ 208V 10,000 @ 200V I 11,400@240V I 11400 @240V 111400 @240V 5000@ 208V 10,000 @ 200V 30 Up to the inverter's rated stand-alone power 8uilt-in(9) Stand-alone & Battery Storage With Backup Interface (purchased sepa-ately) for service up to 200A; up to 3 ini,erters EV Charging Direct coonection to the SdarEdge Home EV Charger ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, Cellular"�, Wi-Fi (optionaO, SdarEdge Horne Network (optional) Revenue Grade Metering, ANSI C12.20 Integrated AC, DC and Communicatioo Connection Unit Yes Inverter Commissioning With the SetApp mobile apj'.Aication using built-in Wi-Fi Acce-.;s Point for local connection DC Voltage Rapid Shutdown (PV and Battery) Yes, NEC 690.12 STANDARD COMPLIANCE Safety UL 1741, UL 17415A. UL 1741S8, UL 1699B, CSA 22.2#107.1, C22,2#330, C22.3#9, ANSVCAN/UL 9540 Grid Connection Standards IEEE1547 and IEEE-1547.1, Rule 21, Rule 14H Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Terminals L 1, L2, N terminal bbd:s, PE bus bar for inverter connection Ll, L Z terminal blocks, PE busbar for EV Charaer AC connection DC Terminals 4 x terminal block pairs for PY input; 1 x terminal block pair for battery input AC Output and EV AC Output Conduit Size/ AWG Range 1" maximum/ 14-4 AWG DC Input (PV and Battery) Conduit Size/ AWG Range 1''maximum/14-6 AWG Dimensions with Connectioo Unit (H x W x D) 21.06 X 14.6 X 8.2 / 535 X 370 X 208 Weight with Connection Unit 44.9/ 20.3 Noise <SO Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+60[!� Protection Rating NEMA 4X (8) Discharge power is Umited up to the inverter's rated AC pa,verfor on-grid and st111d·alooe ap�ications. as well as up to the installed batteries' rating. (9) Frx consumption metering rurrent transformers should be ordered separatety: SECT-Sf>l-22S,.,·T-20 or SEACT1250·400NA-20. Re,..,,m.ie grade metering is onty for production metering. (10) lnfamation concerning the data �an terms & oonditions Is available In SQlarffh: C-OmmunirnriQn i>litn Tmms and Condttion5 (TI) Full power up to at lei:ISl 5lJ'C / 122"F; for power· derating information refer to thf' Ternne@tmr Per;tl ng I Khn ml N91e roe NPC!b Amefica ClSolarEd;JeTeclvxllog""'-Ltrl.All righl,,-wd.SOIAl!E.DGf.theSotalEdgel ogQO!'TIMIZEVIIYSOIAl!E.DGE,:,re1rademarksorregistffedtradematksol"Solar!idgeTe::��lnc. Alothertrildemarksmentionedherelnaretrademarks oftheirresp«1i1-eowners. Oate.:�19.20240S-«10229-NAM. Subject:tochangewilhout OOlia. w w Ade in/mm lb/lg d8A "F/"C PAGE 11 5402 W Lehnhardt Ave11/25/2024 Power Optimizer -c 0 For Residential Installations S440 / S500 / ��0��/ S650B m ;o 0 -c --N m ;o Enabling PV power optimization at the module level I Specifically designed to work with SolarEdge residential inverters I Detects abnormal PV connector behavior, preventing potential safety issues* I Module-level voltage shutdown for installer and firefighter safety I Superior efficiency (99.5%) • Functionality subject to inverter model and firmware version solaredge.com I I I I Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading Faster installations with simplified cable management and easy assembly using a single bolt Flexible system design for maximum space utilization Compatible with bifacial PV modules so I a r ffl t!li-4 I Power Optimizer For Residential Installations S440 / S500 / �f O��/ S650B ,,, -5500B 5650B UNIT INPUT Rated Input DC Power0l 440 I 500 I 650 Absolute Maximum Input Voltage (Voe) 60 I 125 I 85 MPPT Operatinq Ranqe 8-60 I 12.5 -105 I 12.5 -85 Maximum Short Circuit Current (lsc) of Connected PV Module 14.5 I Maximum Efficiencv 995 Weighted Efficiency 98.6 Overvoltage Category II OUTPUT DURING OPERATION Maximum Output Current 15 15 Maximum Output Voltage 60 80 OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer STANDARD COMPLIANCE'2l 1 ± 0.1 EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-7122018-12 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltaqe 1000 Dimensions (W x L x H) 129 X 155 x 3Q I 129 X 165 X 45 Weiqht 720 I lnout Connector MC4ill Input Wire Lenqth 0.1 Output Connector MC4 Output Wire Lenqth (+) 2.3, (-) 0.10 Operatinq Temperature Ranqe14l -40 to +85 Protection Ratinq IP68 Relative Humidity 0-100 (1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed. (2) For details atx:iut CE compliance, see Declaration of Conformity-CE. (3) For other connector types please contact SolarEdge. (4) Power de-rating is applied for ambient temperatures above +BS°C for S440 and SS00, and for ambient temperatures aOOve +75°C for SS00B. Refer to the Power Optimizers Temperature De-Rating Technical Note for details. 790 SolarEdge Home SolarEdge Home Three Phase for PV System Design Using a SolarEdge lnverter15l Wave Inverter Short String Inverter g g (Power Optimizers) I S500B, S650B Maximum String Length (Power Optimizers) Maximum Continuous Power per Strinq Maximum Allowed Connected Power per String1'l (In multiple string designs, the maximum is permitted only when the difference in connected oower between strinas is 2,000W or less) Parallel Strinqs of Different Lenqths or Orientations Single Phase 6 25 5700 68001n (5) It is not allowed to mix S-series and P-series Power Optimizers in new installations in the same string Three Phase 230/400V Grid 8 20 5625 11,250 See1'l 13,500 Yes 14 50 Three Phase for 277/480V Grid 12,750 15,000 w Vdc Vdc Ade % % Ade Vdc Vdc Vdc mm qr m m ·c% (6) If the inverter's rated AC power:,. maximum continuous power per string, then the maximum connected power per string will be able to reach up to the inverters maximum input DC power. Refer to the Single String Design Guidelines application note. (7) For inverters with a rated AC power � 8000W that are connected to at least two strings. 82 J 5440, 5500 (Flat Bracket) I SS00B, 5650B (Bent Bracket) w w © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE. the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarts or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: August 21, 2023 DS-000091-ENG. Subject to change without notice. CE RoHS PAGE 12 5402 W Lehnhardt Ave11/25/2024 SolarEdge Home Battery For North America BAT-10K1P solar .ll:Jm' 10 YEAR WARRANTY -m V1 Optimized for SolarEdge Home Hub lnverters C1 > I DC coupled battery featuring superior overall system efficiency, generating more energy to store and use for on-grid and backup power applications I Integrates seamlessly with the complete SolarEdge Home ecosystem using SolarEdge Home Network, offering a single source for warranty, support, and training, to streamline logistics & operations I Enhanced safety with Rapid Shutdown, SafeDC" I Qualified by the latest and most stringent UL fire safety standard • Backup applk:ations are subject to local regulation and may require additional components and finnware-upgrade solaredge.com I I I Solar, storage, EV charging, and smart devices all monitored and managed by a single app to an optimized production, consumption, and backup* power Simple plug and play installation, with automatic SetApp-based configuration Flexible installation -wall or floor mount, all indoor or outdoor I Wireless communication to the inverter, reducing wiring, labor, and installation solar+=Dtit? I SolarEdge Home Battery For North America BAT-10K1 P BATTERY SPECIFICATION Usable Energy (100% depth of discharge) Continuous Output Power Peak Output Power (for 10 seconds) Peak Roundtrip Efficiency Warranty<1l Voltage Range Communication Interlaces Batteries per Inverter I STANDARD COMPLIANCE I Cell Certification I Battery Emissions I MECHANICAL SPECIFICATIONS Dimensions (W x H x D) Weight Mounting Operating Temperature(') Storage Temperature (more than 3 months) Storage Temperature (less than 3 months) Altitude BAT-10K1PS0B-02 9700 5000 7500 >94.5 10 350-450 Wireless and RS4S5�l Up to 3'3l UL1642 UL 1973, UL9540A, UL9540, UN3B.3 FCC Part 15 Class B 31.1 X 46.4 X 9.84 / 790 X 1179 X 250 262 I 119 Floo�•l or wall mount�l + 74 to + 122 / -10 to + 50 + 14 to +86 / -10 to +30 -22 to + 140 / -30 to +60 6562 /2000 Enclosure Protection IP55 / NEMA 3R -indoor and outdoor (water and dust protection) Cooling Natural convection Noise (at 1m distance) <25 (1) For warranty details, see the SolarEdge Home Battery Limited Product Warranty. (2)The SolarEdge Home Battery is designed for use with SolarEdge Home Network for wireless communication. The inverter might require a matchirg SolarEdge Home Network Plug-in (more details below). Using RS485 could reduce the usable energy to 9500Wh. (3) Installations with multiple SolarEdge Home Battery connected to a single inverter require a pair of branch connectors (DC + and DC -) per battery excluding the last battery. The branch connectors should be purchased separately. (4)The floor stand is purchased separately. One floor stand is required per SolarEdge Home Battery. See the Accessories P/N table below. (S)Wall mount installation requires handles that should be purchased separately. See the Accessories P/N table below. (6) Note that operating the SolarEdge Home Batteries at extreme temperatures for extended durations of time may void the SolarEdge Home Battery warranty coverage. Please see the SolarEdge Home Battery Limited Product Warranty for additional details. IAC-RBAT-FLRSTD-01 Branch con nectors set (includes a pair of DC + and DC -connectors) Re uired for installations with multi le SolarEd e Home Batteries with a sin le inverter IAC-RBAT-USYCBL-01 Handles IAC-RBAT-HANDLE-01 SolarEdge Home Network Plug-in ENET-HBNP-01 Wh w w % Years Vdc in/mm lb/ kg ·r 1 ·c ·r 1 ·c ·r / ·c ft/m dBA Cl SolarEdge Technologies, Ud. All rights reserved SOLAREOGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolcRdge Technologies, Im:. All other trademarks mentioned herein are trademarks of their respective owners. Date: August 14, 2022 DS-000167-NAM. Subject to change without nolice. CE: RoHS PAGE 13 5402 W Lehnhardt Ave11/25/2024 .#A..IRONRIDGE Release Liner shown for reference ITEM NO FIFI QuickMount® Halo UltraGrip® DESCRIPTION RD STRUCTURAL SCREW PN RD-1430-01-M1 SOLD SEPARATELY SHOWN FOR REFERENCE QTY IN KIT QM Halo UltraGrip(Mill or Black) PART NUMBER DESCRIPTION QM-HUG-01-M1 Halo UltraGrip -Mill QM-HUG-01-B1 Halo UltraGrip -Black © 2023 lronRidge, Inc. All rights reserved. Visit WlrVW.ir-patents.com for patent information. QM-HUG-01-81 or QM-HUG-01-M1 Cut Sheet Rev 1.01 FIFI 1.Halo UltraGrip .38 3.35 --------3.83 -------,-�I -j .40 f- dQ).26 0 1.63 1.56 0 0 .34 300� Property Value Material 300 Series Aluminium Finish Mill or Black © 2023 lronRidge, Inc. All rights reserved. Visit www.ir-patents.com for patent information QM-HUG-01-61 or QM-HUG-01-M1 Cut Sheet Rev 1.01 PAGE 14 5402 W Lehnhardt Ave11/25/2024 IIN =MI �IRONRIDGE XR Rail © Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails© are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails© is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs Corrosion-Resistant Materials ■ XR Rails© are compatible with FlashFoot© and other pitched roof attachments. ■ lronRidge©offers a range of tilt leg options for flat roof mounting applications. All XR Rails© are made of 6000-series aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. IIN =MI XR Rail© Family The XR Rail© Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail© to match. i I I XR10 XR10 is a sleek, low-profile mounting rail, designed for regions with light or no snow. It achieves spans up to 6 feet, while remaining light and economical. L 6' spanning capability Moderate load capability Clear & black anodized finish Internal splices available Rail Selection -1=-=-- XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 1 0 feet. 1 0' spanning capability Heavy load capability Clear & black anodized finish Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans up to 12 feet for commercial applications. 12' spanning capability Extreme load capability Clear anodized finish Internal splices available The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria: ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit Iron Ridge.com for detailed certification letters. Load Rail Span Snow (PSF) • 5' 4" 90 120 None 140 XR10 XR100 XR1000 160 90 120 20 140 160 90 30 160 90 40 160 80 160 120 160 'Table is meant to be a simplified span chart for conveying general rail capabilities. Use approved certification letters for actual design guidance. © 2022 lronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.21 PAGE 15 5402 W Lehnhardt Ave11/25/2024 hid:@■ .dA..IRONRIDGE UFO® Family of Components Simplified Grounding for Every Application The UFO ® family of components eliminates the need for separate grounding hardware by bonding solar modules directly to Iron Ridge® XR Rails®. All system types that feature the UFO ® family-Flush Mount®, Tilt Mount® and Ground Mount®-are fully listed to the UL 2703 standard. UFO® hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. Only for installation and use with lronRidge products in accord with written instructions. See lronRidge.com/UFO Stopper Sleeve The Stopper Sleeve snaps onto the UFO®, converting it into a bonded end clamp. Bonded Structural Splice connects rails with built-in bonding teeth. No tools or hardware needed. A single Grounding Lug connects an entire row of PV modules to the grounding conductor. Universal Fastening Object {UFO®) The UFO® securely bonds solar modules to XR Rails®. It comes assembled and lubricated, and can fit a wide range of module heights. Bonded Attachments The bonding bolt attaches and bonds the L-foot® to the rail. It is installed with the same socket as the rest of the system. System Diagram -------------------rn--------------------------------------------------------- -------------------rn-------------------------------------- ------------------- ---rn------ --- ---rn------ --- QUFO Stopper Sleeve • Grounding Lug [I] BOSS"" Splice _J_ Ground Wire � Approved Enphase microinverters can provide equipment grounding of lronRidge systems, eliminating the need for grounding lugs and field installed equipment ground conductors (EGG). A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification The lronRidge® Flush Mount®, Tilt Mount®, and Ground Mount Systems have been listed to UL 2703 by lntertek Group pie. UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. � Go to lronRidge.com/UFO Feature XR Rails® UFO®/Stopper BOSS® Splice Grounding Lugs Microinverters & Power Optimizers Fire Rating Modules Cross-System Compatibility; Flush Mount Tilt Mount Ground Mount XR100 & XR1000 N/A 1 per Row 1 per Row 1 per Array Compatible with most MLPE manufacturers. Refer to system installation manual. Class A Class A N/A Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. © 2022 lronR1dge, Inc. All rights reserved. V1s1t www.ir-patents.com for patent information. Version 1.23 PAGE 16 5402 W Lehnhardt Ave11/25/2024 �IRONRIDGE ITEM NO. UFO-CL-01-A 1 UFO-CL-01-Bl COMPATIBLE WITH 30-46mm MODULE "T ES .25 -- Property Material Finish lfE,iMi Universal Fastening Object® Only for installation and use with lronRidge products in accord with written instructions see lronRidge.com/UFO UNIVERSAL FASTENING OBJECT® DESCRIPTION UNIVERSAL MODULE CLAMP, CLEAR UNIVERSAL MODULE CLAMP, BLACK .29 (/) .37 r7/16"Head @ "'-- (/) l. l 2 . Value I 300 Series Stainless Steel I Clear and Black I v1 .32 �IRONRIDGE Stopper Sleeve® Dim"X" See Table l ITEM NO. Only for installation and use with Iron Ridge products in accord with written instructions see Iron Ridge.com/UFO UNIVERSAL FASTENING OBJECT COMPONENT STOPPER SLEEVE TABLE 1: STOPPER SLEEVE PART NUMB ES AND HEIGHT MILL PART NUMBER BLACK PART NUMBER HEIGHT "X" (mm) UFO-STP-30MM-M l UFO-STP-30MM-B l 30 UFO-STP-32MM-M l UFO-STP-32MM-B l 32 UFO-STP-33MM-M l UFO-STP-33MM-B l 33 UFO-STP-35MM-M l UFO-STP-35MM-B l 35 UFO-STP-38MM-M l UFO-STP-38MM-B l 38 UFO-STP-40MM-M l UFO-STP-40MM-B l 40 UFO-STP-42MM-M l UFO-STP-42MM-B l 42 UFO-STP-46MM-M l UFO-STP-46MM-B l 46 Property Value Material 6000 Series Aluminum Finish Mill or Black ----l 1.09 f-- v1.32 PAGE 17 5402 W Lehnhardt Ave11/25/2024 .#A.IRONRIDGE See Descri tion / Length .62 .46 Rail Section Prooerties Property Total Cross-Sectional Area Secfrion Modulus /X-axis! Moment of !Inertia {X�axisl Moment of !Inertia {Y-axis! Torsional Constant Polar Moment of Inertia Clear Part Black Part Description/ Length Material Number Number XR-10-132A XR-10-132B XRlO, Rail 132" (11 Feet) 6000-Series XR-10-l 68A XR-10-168B XRl0, Rail 168" (14 Feet) XR-10-204A XR-10-204B XR l 0, Rail 204" ( 17 Feet) Aluminum v1 .01 ''""'' XR10 ® Rail Value 0.363 in 2 0.136 in 3 0.124in 4 0.032in 4 0.076 in J 0.033 in 4 Weight 4.67 lbs. 5.95 lbs. 7.22 lbs. I I I I 5402 W Lehnhardt Ave11/25/2024 To Whom it may concern, Hello, I __________________________, residing at ____________________________________ would like to authorize Luxor Energy LLC to install solar panels at my property. They are granted permission to do anything they need for the installation on my behalf. Please let me know if you have any questions or concerns. Homeowner Address: 11740 Sterling Ave, Riverside, CA, 92503 Trang Do 5402 W. Lehnhardt Avenue, Santa Ana, CA 92704 Trang Do (Nov 7, 2024 11:08 PST) Trang Do 5402 W Lehnhardt Ave11/25/2024 Luxor HO auth Final Audit Report 2024-11-07 Created:2024-11-07 By:John Detlefson (snezana@myluxorenergy.com) Status:Signed Transaction ID: CBJCHBCAABAAdAKIVuuFVTDQTnuB_q5aqWjdMlGiv33f "Luxor HO auth" History Document created by John Detlefson (snezana@myluxorenergy.com) 2024-11-07 - 7:06:57 PM GMT Document emailed to Dothuytrang2006vn@yahoo.com for signature 2024-11-07 - 7:07:10 PM GMT Email viewed by Dothuytrang2006vn@yahoo.com 2024-11-07 - 7:07:23 PM GMT Signer Dothuytrang2006vn@yahoo.com entered name at signing as Trang Do 2024-11-07 - 7:08:02 PM GMT Document e-signed by Trang Do (Dothuytrang2006vn@yahoo.com) Signature Date: 2024-11-07 - 7:08:04 PM GMT - Time Source: server Agreement completed. 2024-11-07 - 7:08:04 PM GMT 5402 W Lehnhardt Ave11/25/2024 Miguel ArrezolaEvan Forbush 5402 W Lehnhardt Ave11/25/2024 5402 W Lehnhardt Ave11/25/2024 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 5402 W. Lehnhardt Ave Luxor Energy Inc 1102673 Alex Jurado 951-373-9218 11-15-24 jr.jurado@myluxorenergy.com 5402 W Lehnhardt Ave11/25/2024