HomeMy WebLinkAbout542 E Central Ave - Plan1 HOUSE PHOTO PV-0 SCALE: NTS
COVER PAGE
PROJECT SITE
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-0
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATE DESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024 AHJ REQUESTED
PDF FORM FILLED
SHEET INDEX
PV-0 COVER PAGE
PV-1 SITE PLAN
PV-2 ROOF PLAN & MODULES
PV-2A STRING LAYOUT & BOM
PV-3 ATTACHMENT DETAILS
PV-4 ELECTRICAL LINE DIAGRAM & CALCS.
PV-4A SPECIFICATIONS & CALCULATION
PV-5 SIGNAGE
PV-6+EQUIPMENT SPECIFICATIONS
SCOPE OF WORK:
TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER PROPERTY
LOCATED AT 542 E CENTRAL AVE, SANTA ANA, CA 92707
THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONCECTED WITH THE UTILITY
GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT.
GENERAL NOTES:
· THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND
OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE
MODIFICATIONS IN CONSTRUCTION DETAILS.
· ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR
INSTALLATION OF ANY EQUIPMENT AT SITE.
· CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL
PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION.
· CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS
AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER
BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION
AND ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE
CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL
COMPENSATION.
· DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL,
FLOORS, ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE
CONTRACTOR AT NO ADDITIONAL COST.
· THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND
COMPLETION OF THE WORK WITH APPROVED MATERIALS.
· NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE
ARCHITECT.
· CONTRACTOR SHALL OBTAIN BULDING PERMIT. NO WORK TO START UNLESS BUILDING
PERMIT IS PROPERLY DISPLAYED.
· ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE
WITH THE REQUIREMENTS OF THE CA BUILDING CODE, THE DEPARTMENT OF
ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES.
· IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL
PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING.
THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH.
· ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO
BE PAINTED BY GENERAL CONTRACTOR.
· THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE
LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE.
· THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS,
CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES.
·CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK.
·THE PV SYSTEM MUST BE INSTALLED AND APPROVED PRIOR TO FINAL APPROVAL OF THE
BUILDING TO MEET THE REQUIREMENTS OF CAEC 150.1(C)(14).
ELECTRICAL NOTES:
· THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONCECTION SHALL BE INSTALLED ONLY BY QUALIFIED PEOPLE. A QUALIFIED PERSON IS
ONE WHO HAS SKILLS AND KNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OF THE ELECTRICAL EQUIPMENT AND INSTALLATIONS
AND HAS RECIEVED SAFETY TRAINING TO RECOGNIZE AND AVOID THE HAZARDS INVOLVED. (CEC 690.4(E) AND 705.6)
· LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. FOR A LINE SIDE TAP
CONCECTION, UTILITY NEEDS TO BE NOTIFIED WELL IN ADVANCE TO COORDINATE BUILDING ELECTRICAL SHUT OFF.
· NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC. SUBCONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONS AND THE
COORDINATION REQUIREMENTS OF OTHER TRADES.
·ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TO QUALIFIED PERSONNEL.
·ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WATERTIGHT AND APPROVED FOR USE IN WET LOCATIONS. (CEC 314.15A).
·WIRING METHODS FOR PV SYSTEM CONDUCTORS AREN'T PERMITTED WITHIN 10 IN. OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE LOCATED
DIRECTLY BELOW THE ROOF SURFACE THAT'S COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT WIRING
·BACK-FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES.
·ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARE LISTED AS UV RESISTANT.
·CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS IN CEC 690 AND CFC 2022
·PV SOURCE, OUTPUT AND INVERTER CIRCUITS SHALL BE IDENTIFIED AT ALL POINTS OF TERMINATION, CONCECTION, AND SPLICES. THE MEANS OF ID
CAN BE SEPARATE COLOR CODING, MARKING TAPE, TAGGING ETC. (CEC 690.4).
· MEASURE THE LINE-TO-LINE AND LINE-TO-NEUTRAL VOLTAGE OF ALL SERVICE ENTRANCE CONDUCTORS PROIR TO INSTALLING ANY SOLAR
EQUIPMENT. THE VOLTAGES FOR THE 208VAC RATED.
WIRING AND CONDUIT NOTES:
· ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS
PURPOSE AND APPROVED FOR THE SITE APPLICATIONS
· ALL PV CABLES AND HOMERUN WIRES BE #10AWG *USE-2, PV
WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY MFR,
OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER
BOXES AS REQUIRED
· ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED
ACCORDING TO [CEC 690.8 (A)(1) & (B)(1)], [CEC 240] [CEC
690.7] FOR MULTIPLE CONDUCTORS
· ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT
SHALL BE DERATED ACCORDING TO [CEC TABLE 310.15
(B)(2)(C)] BLACK ONLY**
· EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C
RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR
600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT
WIRE FROM SHARP EDGES
· PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED
THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV
RESISTANT, RATED FOR 600V PER CEC 2008 OR 1000V PER
CEC 2011
· 4-WIRE DELTA CONCECTED SYSTEMS HAVE THE PHASE WITH
THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR
IDENTIFIED BY OTHER EFFECTIVE MEANS
· ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE
CIRCUIT PROTECTION
·VOLTAGE DROP LIMITED TO 2%
·AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE
A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE,
NEUTRAL- WHITE/GRAY
2 VICINITY MAP PV-0 SCALE: NTS
GOVERNING CODES
2022 CALIFORNIA BUILDING CODE
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA FIRE CODE
2022 CALIFORNIA PLUMBING CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA ENERGY CODE
2022 CALIFORNIA RESIDENTIAL CODE
2022 CALIFORNIA ADMINISTRATIVE CODE
EQUIPMENT SUMMARY
06 HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W MODULES
02 APS QT2 -208 3-PHASE (208V) MICRO-INVERTERS
SYSTEM RATING
2.520 KWDC
3.456 KWAC
PROJECT SITE
PROJECT SITE
Bldg#: 101118106
Elec#: 20181990
Approvals:
Bldg: KAhangian
Elec: MSmith
Plng: CSantana
The scope of the plans is for
the installation of the solar
photovoltaic system only
and the approval is subject
to compliance with all
applicable city and state
codes and regulations
regarding construction. The
approval of the plans does
not constitute any
certification of the accuracy,
completeness, or building
permit status of the existing
buildings and structures as
shown.
542 E Central Ave - 101118106 &
20181990
4/25/2024
15
2
'
-
1
0
"
12
6
'
-
4
"
61'-10"
72'-4"
19
'
-
8
"
6'-11"
10
'
-
2
"
19'-4"
36'
-
8
"
DP
B
UM
AC
GA
T
E
W
A
Y
1LPA
PLOT PLAN WITH ROOF PLAN
PV-1
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-1
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
SITE NOTES
·A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA
REGULATIONS.
·THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN
UTILITY INTERACTIVE SYSTEM.
·THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL,
OR BUILDING ROOF VENTS.
·PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED
ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [CEC 110.26]
1
SCALE: 1/16" = 1'-0"
SITE PLAN
(E) DRIVEWAY
ROOF #1
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W MODULES
PR
O
P
E
R
T
Y
L
I
N
E
2-STORY
PROPERTY LINE
E CENTRAL AVE
(E) WALKWAY
S
H
A
L
L
A
D
A
Y
S
T
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
(N) VISIBLE LOCKABLE LABELED
FUSED AC DISCONNECT
30A, 208V, 3P, 3W, NEMA 3R,
FUSED WITH 30A CLASS R FUSES
(E) GRID TIED UTILITY METER WITH
DISTRIBUTED PANEL BOARD
400A,208Y/120V, 3PH, 4W, NEMA 1
(WITH ATTACHED 1LPA
200A,208Y/120V, 3PH, 4W, NEMA 1)
(N) APS ECU-C GATEWAY
THERE'S AN EXISTING
OUTLET IN THIS AREA
THAT IS FED FROM
CIRCUIT 1LP-12
TO ADD ANOTHER 120V OUTLET HERE TO
BE FED FROM 1LP-12 WHICH IS THE SAME
CIRCUIT THAT THE EXISTING OUTLET IS
SHOWN TO FEED FROM IN THIS ROOM
IT NEEDS TO BE FUSED WITH CLASS R
FUSES IN ORDER TO BE RATED 200KAIC.
OTHERWISE IT WILL ONLY HAVE A
WITHSTAND RATING (SCCR) OR 10KAIC.
10KAIC IS NOT ACCEPTABLE BECAUSE THE
FAUL CONTRIBUTION FROM SCE IS 42KAIC
NO
P
A
R
K
I
N
G
A
R
E
A
542 E Central Ave - 101118106 &
20181990
4/25/2024
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-10
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
EQUIPMENT
SPECIFICATION
542 E Central Ave - 101118106 &
20181990
4/25/2024
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-11
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
EQUIPMENT
SPECIFICATION
542 E Central Ave - 101118106 &
20181990
4/25/2024
6'-10"3'-3"17'-8"
20
'
-
8
"
25
'
-
1
0
"
3'
-
6
"
4'-10"3'-5"1'-10"
6'
-
0
"
4'
-
6
"
DP
B
UM
AC
GA
T
E
W
A
Y
JB
1'
-
1
0
"
36" CLEARANCE
6'
-
0
"
1LPA
ROOF PLAN & MODULES
SCALE: 1/16" = 1'-0"
ROOF PLAN &
MODULES
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-2
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
HANWHA Q.CELLS:
Q.PEAK DUO
L-G8.3/BFG 420W
MODULES
81
.
9
"
40.5"
DESIGN SPECIFICATION
RISK CATEGORY:II
CONSTRUCTION:SFD
ZONING:RESIDENTIAL
SNOW LOAD (ASCE 7-16):0PSF
EXPOSURE CATEGORY:B
WIND SPEED (ASCE 7-16):95MPH
MODULE TYPE, DIMENSIONS & WEIGHT
NUMBER OF MODULES:06 MODULES
MODULE TYPE:
HANWHA Q.CELLS:
Q.PEAK DUO L-G8.3/BFG
420W
MODULE WEIGHT:62.8 LBS
MODULE DIMENSIONS:81.9" x 40.5" = 23.03SF
UNIT WEIGHT OF AREA:2.15 PSF
PV-2
1
LEGEND
- VENT, ATTIC FAN (ROOF OBSTRUCTION)
- ROOF ATTACHMENT
- CONDUIT
(N) GATEWAY
(E) UTILITY METER
(N) AC JUNCTION BOX
UM
(E) DISTRIBUTION PANEL BOX (DPB)DPB
JB
(N) AC DISCONNECTAC
ROOF DESCRIPTION
ROOF ROOF
TILT AZIMUTH RAFTER
SIZE
RAFTER
SPACING ROOF MATERIAL
#1 16°270°2"X4"24" o.c.CLAY S TILE
ARRAY AREA & ROOF AREA CALC'S
ROOF # OF
MODULES
ARRAY
AREA
(Sq. Ft.)
TOTAL
ROOF
AREA
(Sq. Ft.)
TOTAL
ROOF
AREA
COVERED
BY ARRAY
(%)
#1 06 138 1454 10
TOTAL ROOF AREA
COVERED BY ARRAY
AREA (%)
138 1454 10
(E)FRONT YARD
E CENTRAL AVE
(E)BACK YARD
(N) 3/4" ATTIC RUN
(N) AC JUNCTION BOX
(N) VISIBLE LOCKABLE LABELED
FUSED AC DISCONNECT
30A, 208V, 3P, 3W, NEMA 3R,
FUSED WITH 30A CLASS R FUSES
(E) GRID TIED UTILITY METER
WITH DISTRIBUTED PANEL BOARD
400A,208Y/120V, 3PH, 4W, NEMA 1
(WITH ATTACHED 1LPA
200A,208Y/120V, 3PH, 4W, NEMA 1)
ROOF #1
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W MODULES
(N) APS ECU-C GATEWAY
(N) IRONRDIGE XR-100 RAIL
(02) APS QT2 -208 3-PHASE (208V)
MICRO-INVERTERS (08) FJE-450 FASTJACK ATTACHMENTS
@ 72" O.C.
RO
O
F
#
1
TI
L
T
-
16
°
AZ
I
M
.
-
27
0
°
36 INCH FIRE SETBACK
36 INCH FIRE SETBACK
S
H
A
L
L
A
D
A
Y
S
T
GATEWAY
OUTLET
(E) 1 LPA1LPA
542 E Central Ave - 101118106 &
20181990
4/25/2024
DP
B
UM
AC
GA
T
E
W
A
Y
JB
1LPA
ROOF PLAN WITH STRING LAYOUT & BOM
SCALE: 1/16" = 1'-0"
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-2A
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
STRING
LAYOUT & BOM
PV-2A
1 (E)BACK YARD
BILL OF MATERIALS
EQUIPMENT QTY DESCRIPTION
SOLAR PV MODULE 06 HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W MODULES
INVERTER 02 APS QT2 -208 3-PHASE (208V) MICROINVERTER
JUNCTION BOX 1 AC JUNCTION BOX, NEMA 3R, UL LISTED
GATEWAY 1 APS ECU-C GATEWAY
AC DISCONNECT 1 30A FUSED AC DISCONNECT,30A, 208V, 3P, 3W, NEMA 3R,
FUSED WITH 30A CLASS R FUSES
ATTACHMENT 8 FJE-450 FASTJACK ATTACHMENTS
RAILS 4 IRONRDIGE XR-100 RAIL RAIL- 14 FEET (168")
MID CLAMP 10 MODULES CLAMPS (MID CLAMPS)
END CLAMP 4 MODULES CLAMPS ( END CLAMPS)
GROUNDING LUG 1 GROUNDING LUG
A-
1
A-
2
A-
3
(E)FRONT YARD
E CENTRAL AVE
- MODULE STRINGINGA
S
H
A
L
L
A
D
A
Y
S
T
A-
4
A-
5
A-
6
INVERTER-1A-1 A-3A-2
INVERTER-2A-4 A-6A-5
STRING NO:-1
542 E Central Ave - 101118106 &
20181990
4/25/2024
IRONRIDGE INTEGRATED GROUNDING &
END/MID CLAMP (E) CLAY S TILE ROOF SURFACE
PV MODULE
(E) STRUCTURAL MEMBER
FLASHED L-FOOT
(1) 5/16"DIA. X 3" MIN.
EMBEDMENT LAG SCREW
AT EACH ATTACHMENT POINT
INTO EXISTING FRAMING
FASTJACK
CHANNEL NUT
FLASHING
IRONRIDGE XR-100 RAIL
4-1/2" TALL FASTJACK E-SERIES
(PART #FJE-450)
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-3
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
ATTACHMENT
DETAILS .
PV-3
ATTACHMENT DETAIL (enlarged view)
PV-3 SCALE: NTS
1
542 E Central Ave - 101118106 &
20181990
4/25/2024
06- HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W MODULES
BRANCH 1
(02) APS QT2 -208 3-PHASE (208V) MICROINVERTERS
AC BUS
CABLE (N) JUNCTION BOX
600 V, NEMA 3R, UL
LISTED
G
2
L2
L1
G
1
L3
3
(N) AC DISCONNECT:
30A, 208V, 3P, 3W,
NEMA 3R, FUSED WITH
30A CLASS R FUSES
(3) 30A FUSES
L2
L1
L2
L1
N N
G G
(N) VISIBLE LOCKABLE
LABELED DISCONNECT
L1
L2
L1
L2
L1
L2
30A/3P
(E) 1 LPA (16.0 KVA)
200A, 208Y/120V,
3PH, 4W, NEMA 1
(10 KAIC)
(E) MAIN BREAKER TO
HOUSE 208 V, 100A/3P
BACK FEED BREAKER AT
THE OPPOSITE END OF
THE MAIN BREAKER
L3L3 L3 L3
L3
GATEWAY
(N) APS ECU-C GATEWAY
(N) FACTORY CORD TO
(E) OUTLET IN ELECTRIC RM
L1
L2
L3
NN
L2
L1
L3
L1
L2
EXISTING GROUND
ELECTRODE CONDUCTOR
(E) DISTRIBUTED PANEL
BOARD 400A, 208Y/120V,
3PH, 4W, NEMA 1
(10 KAIC)
BI-DIRECTIONAL UTILITY
3-PH, 208Y/120V
TO UTILITY GRID
(E) MAIN BREAKER TO
HOUSE 208 V, 400A/3P
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
(E) SPD
(E) 1 LPA
(18.3 KVA)
(E) 2 LPA
(54.3 KVA)
EE
E
E
225A/3P
150A/3P
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-4
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
ELECTRICAL LINE
1 ELECTRICAL LINE DIAGRAM
PV-4 SCALE: NTS
&CALCS.
ID TYPICAL INITIAL CONDUCTOR
LOCATION
FINAL CONDUCTOR
LOCATION CONDUCTOR CONDUIT
# OF
PARALLEL
CIRCUITS
CURRENT-CARRYING
CONDUCTORS IN
CONDUIT
CONDUIT FILL
PERCENT OCPD EGC TEMP. CORR.
FACTOR
CONDUIT
FILL FACTOR
CONT.
CURRENT (A)
MAX.
CURRENT (A)
BASE
AMP. (A)
DERATED
AMP. (A)
TERM.
TEMP.
RATING
LENGTH VOLTAGE
DROP
1 1 ARRAY JUNCTION BOX 10 AWG AC BUS CABLE -1 4 (L1,L2,L3)N/A N/A 10 AWG BARE
COPPER 0.71 (53°C)N/A 9.6 12.00 N/A N/A 90°C 80FT 0.83%
2 1 JUNCTION BOX ACD 10 AWG THWN-2 COPPER MIN 0.75" Dia EMT 1 4 (L1,L2,L3)19.09%30A 10 AWG THWN-2,
COPPER 0.94 (31°C)1 9.6 12.00 35 32.90 75°C 26FT 0.27%
3 1 ACD DPB 10 AWG THWN-2 COPPER MIN 0.75" Dia EMT 1 4 (L1,L2,L3)19.09%30A 10 AWG THWN-2,
COPPER 0.94 (31°C)1 9.6 12.00 35 32.90 75°C 5FT 0.052%
120% RULE
INTERCONCECTION
120% RULE - CEC 705.12(B)(3)(2)
UTILITY FEED + SOLAR BACKFEED
100 A + 30 = 130A
BUSS RATING x 120%
200 A x 120% = 240A
1.ALL GROUNDING ELECTRODES THAT ARE PRESENT AT EACH BUILDING OR STRUCTURE SHALL BE BONDED TOGETHER. (250.50)
2. HEIGHT OF CONDUIT FROM ROOFTOP SHALL BE 7/8".
3. SPLICES/WIRING TRANSITIONS FROM PV WIRE TO BUILDING WIRING TO OCCUR IN A LISTED WP JUNCTION BOX.
4. THE ARRAY EQUIPMENT GROUNDING CONDUCTOR SMALLER THAN 6 AWG, OR THE EQUIPMENT BONDING JUMPERS (IF USED)
SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY RACEWAY OR CABLE ARMOR, INSTALLED IN HALLOW SPACES_
_INSIDE BUILDINGS OR OTHER METHODS AS PERMITTED IN SECTION 250.120(C). (690.46)
5. PV BACKFEED BREAKER TO BE INSTALLED AT OPPOSITE END OF BUSBAR OR INPUT FEEDER.
542 E Central Ave - 101118106 &
20181990
4/25/2024
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-4A
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-4A
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
SPECIFICATIONS
PERCENT OF VALUES
NUMBER OF CURRENT
CARRYING CONDUCTORS
IN EMT
0.80 4-6
0.70 7-9
0.50 10-20
&
INVERTER SPECIFICATIONS
MANUFACTURER / MODEL APS QT2 -208 3-PHASE (208V)
CONTINUOUS OUTPUT
CURRENT 4.8A (208V)
CALC.
AMBIENT TEMPERATURE SPECS
RECORD LOW TEMP 2°C
AMBIENT TEMP (HIGH TEMP 2%)31°C
CONDUIT HEIGHT 0.5"
ROOF TOP TEMP 90°C
CONDUCTOR TEMPERATURE RATE 53°C
MODULE TEMPERATURE COEFFICIENT OF VOC -0.27%/K
SOLAR MODULE SPECIFICATIONS
MANUFACTURER / MODEL HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG
420W
VMP 41.08V
IMP 10.22A
VOC 48.84V
ISC 10.74A
TEMP. COEFF. VOC -0.27%/K
MODULE DIMENSION 81.9"(L) x 40.5"(W)
PANEL WATTAGE 420W
542 E Central Ave - 101118106 &
20181990
4/25/2024
SIGNAGE
ADHESIVE FASTENED SIGNS:
· THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED.
· WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [CEC
110.21(B) FIELD MARKING].
· ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3]
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
LABEL LOCATION:
POINT-OF-INTERCONCECTION OR AT MAIN
SERVICE DISCONNECT (MSP)
PER CODE: 2020 CEC 705.12(B)(3)(2)
WARNING
ELECTRIC SHOCK HAZARD
TERMINALS ON BOTH LINE AND LOAD SIDES MAY
BE ENERGIZED IN THE OPEN POSITION
LABEL LOCATION:
MAIN SERVICE PANEL/AC DISCONNECT/INVERTER/
AC COMBINER
2020 CEC 690.13(B)
!
WARINING PHOTOVOLTAIC POWER SOURCE
LABEL LOCATION:
MAIN SERVICE PANEL/AC DISCONNECT
2020 CEC 690. 13(B)
RATED AC OUTPUT CURRENT 9.6A
NOMINAL OPERATING AC VOLTAGE 208 VAC
PHOTOVOLTAIC AC DISCONNECT
LABEL LOCATION:
INVERTER
AT OR WITHIN 3' OF THE DC COMBINER
SWITCH
2020 CEC 690.56(C)(3)
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
CAUTION!
DUAL POWER SOURCE
SECOND SOURCE IS
PHOTOVOLTAIC
WITH RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH TO THE
"OFF" POSITION TO
SHUT DOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN THE ARRAY
SOLAR ELECTRIC
PV PANELS
1
2
3
4
5
LABEL LOCATION:
AC DISCONNECT
2020 CEC 690.56(C)(3)
PHOTOVOLTAIC SYSTEM
UTILITY DISCONNECT SWITCH
LABEL LOCATION:
MAIN SERVICE PANEL
IF MSD IS OUTSIDE PLACE IT THERE / IF
MSD IS INSIDE PLACE ON THE AC DISCONNECT
2020 CEC 690.56(C)(1)(a)
LABEL LOCATION:
MAIN SERVICE PANEL/AC DISCONNECT/AC COMBINER/
REVENUE METER
2020 CEC 705.12(B)(3)
7
LABEL LOCATION:
DC CONDUIT
EVERY 10' AND ON CONDUIT BODIES WHEN
EXPOSED
2020 CEC 690.31(G)(D)(3)
SERVICE
DISCONNECT
SECTIONNEUR
PRINCIPALE
SERVICIO DE
DESCONEXION
LABEL LOCATION:
AC DISCONNECT
2020 CEC 230.66
9
6 8 PV SOLAR BREAKER
PV ELECTRICAL
EQUIPMENT LAYOUT
LABEL LOCATION:
BUILDING/STRUCTURE,
(PER CODE: CEC 705.10 & 690.56(A)(B))
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-5
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
DP
B
UM
AC
GAT
E
W
A
Y
S
H
A
L
L
A
D
A
Y
S
T
E CENTRAL AVE
1LPA
(N) APS ECU-C
GATEWAY ROOFTOP PV MODULE
(E) DPB TIED TO
UTILITY METER
WITH 1 LPA
(N) FUSED AC
DISCONNECT
542 E Central Ave - 101118106 &
20181990
4/25/2024
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-6
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
EQUIPMENT
SPECIFICATION
542 E Central Ave - 101118106 &
20181990
4/25/2024
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-7
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
EQUIPMENT
SPECIFICATION
542 E Central Ave - 101118106 &
20181990
4/25/2024
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-8
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
EQUIPMENT
SPECIFICATION
542 E Central Ave - 101118106 &
20181990
4/25/2024
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-9
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
EQUIPMENT
SPECIFICATION
542 E Central Ave - 101118106 &
20181990
4/25/2024
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
PV-9.1
DATE: 04/11/2024
54
2
E
C
E
N
T
R
A
L
A
V
E
SA
N
T
A
A
N
A
,
CA
92
7
0
7
OL
G
-
D
E
L
H
I
Signature with Seal
REVDATEDESCRIPTION
REVISIONS
(02) APS QT2 -208 3-PHASE (208V)
SYSTEM INFO.
(06) HANWHA Q.CELLS: Q.PEAK DUO
L-G8.3/BFG 420W
DC SYSTEM SIZE: 2.52 KWDC
AC SYSTEM SIZE: 3.46 KWAC
SPECTRA POWER SYSTEMS
ADDRESS.:- 27892 CALLE SAN REMO,
SAN JUAN CAPISTRANO, CA 92675
CONTACT NAME: KEN RILEY
LICENSE NO.: #1063909
LICENSE CLASS.: C-10
KENR@SPECTRA-POWER.COM
PHONE NO.: 7608159405
CONTRACTOR INFORMATION
B02/02/2024AHJ REQUESTED
PDF FORM FILLED
EQUIPMENT
SPECIFICATION
542 E Central Ave - 101118106 &
20181990
4/25/2024