HomeMy WebLinkAbout542 E Central Ave - Plan1 HOUSE PHOTO PV-0 SCALE: NTS COVER PAGE PROJECT SITE SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-0 DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , C A 9 2 7 0 7 OL G - D E L H I Signature with Seal REVDATE DESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024 AHJ REQUESTED PDF FORM FILLED SHEET INDEX PV-0 COVER PAGE PV-1 SITE PLAN PV-2 ROOF PLAN & MODULES PV-2A STRING LAYOUT & BOM PV-3 ATTACHMENT DETAILS PV-4 ELECTRICAL LINE DIAGRAM & CALCS. PV-4A SPECIFICATIONS & CALCULATION PV-5 SIGNAGE PV-6+EQUIPMENT SPECIFICATIONS SCOPE OF WORK: TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER PROPERTY LOCATED AT 542 E CENTRAL AVE, SANTA ANA, CA 92707 THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONCECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. GENERAL NOTES: · THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE MODIFICATIONS IN CONSTRUCTION DETAILS. · ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR INSTALLATION OF ANY EQUIPMENT AT SITE. · CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. · CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL COMPENSATION. · DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST. · THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND COMPLETION OF THE WORK WITH APPROVED MATERIALS. · NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE ARCHITECT. · CONTRACTOR SHALL OBTAIN BULDING PERMIT. NO WORK TO START UNLESS BUILDING PERMIT IS PROPERLY DISPLAYED. · ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE WITH THE REQUIREMENTS OF THE CA BUILDING CODE, THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. · IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. · ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO BE PAINTED BY GENERAL CONTRACTOR. · THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. · THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. ·CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK. ·THE PV SYSTEM MUST BE INSTALLED AND APPROVED PRIOR TO FINAL APPROVAL OF THE BUILDING TO MEET THE REQUIREMENTS OF CAEC 150.1(C)(14). ELECTRICAL NOTES: · THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONCECTION SHALL BE INSTALLED ONLY BY QUALIFIED PEOPLE. A QUALIFIED PERSON IS ONE WHO HAS SKILLS AND KNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OF THE ELECTRICAL EQUIPMENT AND INSTALLATIONS AND HAS RECIEVED SAFETY TRAINING TO RECOGNIZE AND AVOID THE HAZARDS INVOLVED. (CEC 690.4(E) AND 705.6) · LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. FOR A LINE SIDE TAP CONCECTION, UTILITY NEEDS TO BE NOTIFIED WELL IN ADVANCE TO COORDINATE BUILDING ELECTRICAL SHUT OFF. · NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC. SUBCONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONS AND THE COORDINATION REQUIREMENTS OF OTHER TRADES. ·ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TO QUALIFIED PERSONNEL. ·ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WATERTIGHT AND APPROVED FOR USE IN WET LOCATIONS. (CEC 314.15A). ·WIRING METHODS FOR PV SYSTEM CONDUCTORS AREN'T PERMITTED WITHIN 10 IN. OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE LOCATED DIRECTLY BELOW THE ROOF SURFACE THAT'S COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT WIRING ·BACK-FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. ·ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARE LISTED AS UV RESISTANT. ·CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS IN CEC 690 AND CFC 2022 ·PV SOURCE, OUTPUT AND INVERTER CIRCUITS SHALL BE IDENTIFIED AT ALL POINTS OF TERMINATION, CONCECTION, AND SPLICES. THE MEANS OF ID CAN BE SEPARATE COLOR CODING, MARKING TAPE, TAGGING ETC. (CEC 690.4). · MEASURE THE LINE-TO-LINE AND LINE-TO-NEUTRAL VOLTAGE OF ALL SERVICE ENTRANCE CONDUCTORS PROIR TO INSTALLING ANY SOLAR EQUIPMENT. THE VOLTAGES FOR THE 208VAC RATED. WIRING AND CONDUIT NOTES: · ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE APPLICATIONS · ALL PV CABLES AND HOMERUN WIRES BE #10AWG *USE-2, PV WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED · ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [CEC 690.8 (A)(1) & (B)(1)], [CEC 240] [CEC 690.7] FOR MULTIPLE CONDUCTORS · ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE DERATED ACCORDING TO [CEC TABLE 310.15 (B)(2)(C)] BLACK ONLY** · EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES · PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 600V PER CEC 2008 OR 1000V PER CEC 2011 · 4-WIRE DELTA CONCECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS · ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION ·VOLTAGE DROP LIMITED TO 2% ·AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY 2 VICINITY MAP PV-0 SCALE: NTS GOVERNING CODES 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA ADMINISTRATIVE CODE EQUIPMENT SUMMARY 06 HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W MODULES 02 APS QT2 -208 3-PHASE (208V) MICRO-INVERTERS SYSTEM RATING 2.520 KWDC 3.456 KWAC PROJECT SITE PROJECT SITE Bldg#: 101118106 Elec#: 20181990 Approvals: Bldg: KAhangian Elec: MSmith Plng: CSantana The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 542 E Central Ave - 101118106 & 20181990 4/25/2024 15 2 ' - 1 0 " 12 6 ' - 4 " 61'-10" 72'-4" 19 ' - 8 " 6'-11" 10 ' - 2 " 19'-4" 36' - 8 " DP B UM AC GA T E W A Y 1LPA PLOT PLAN WITH ROOF PLAN PV-1 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-1 DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED SITE NOTES ·A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. ·THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM. ·THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. ·PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [CEC 110.26] 1 SCALE: 1/16" = 1'-0" SITE PLAN (E) DRIVEWAY ROOF #1 (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W MODULES PR O P E R T Y L I N E 2-STORY PROPERTY LINE E CENTRAL AVE (E) WALKWAY S H A L L A D A Y S T PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E PROPERTY LINE (N) VISIBLE LOCKABLE LABELED FUSED AC DISCONNECT 30A, 208V, 3P, 3W, NEMA 3R, FUSED WITH 30A CLASS R FUSES (E) GRID TIED UTILITY METER WITH DISTRIBUTED PANEL BOARD 400A,208Y/120V, 3PH, 4W, NEMA 1 (WITH ATTACHED 1LPA 200A,208Y/120V, 3PH, 4W, NEMA 1) (N) APS ECU-C GATEWAY THERE'S AN EXISTING OUTLET IN THIS AREA THAT IS FED FROM CIRCUIT 1LP-12 TO ADD ANOTHER 120V OUTLET HERE TO BE FED FROM 1LP-12 WHICH IS THE SAME CIRCUIT THAT THE EXISTING OUTLET IS SHOWN TO FEED FROM IN THIS ROOM IT NEEDS TO BE FUSED WITH CLASS R FUSES IN ORDER TO BE RATED 200KAIC. OTHERWISE IT WILL ONLY HAVE A WITHSTAND RATING (SCCR) OR 10KAIC. 10KAIC IS NOT ACCEPTABLE BECAUSE THE FAUL CONTRIBUTION FROM SCE IS 42KAIC NO P A R K I N G A R E A 542 E Central Ave - 101118106 & 20181990 4/25/2024 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-10 DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED EQUIPMENT SPECIFICATION 542 E Central Ave - 101118106 & 20181990 4/25/2024 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-11 DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED EQUIPMENT SPECIFICATION 542 E Central Ave - 101118106 & 20181990 4/25/2024 6'-10"3'-3"17'-8" 20 ' - 8 " 25 ' - 1 0 " 3' - 6 " 4'-10"3'-5"1'-10" 6' - 0 " 4' - 6 " DP B UM AC GA T E W A Y JB 1' - 1 0 " 36" CLEARANCE 6' - 0 " 1LPA ROOF PLAN & MODULES SCALE: 1/16" = 1'-0" ROOF PLAN & MODULES SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-2 DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W MODULES 81 . 9 " 40.5" DESIGN SPECIFICATION RISK CATEGORY:II CONSTRUCTION:SFD ZONING:RESIDENTIAL SNOW LOAD (ASCE 7-16):0PSF EXPOSURE CATEGORY:B WIND SPEED (ASCE 7-16):95MPH MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES:06 MODULES MODULE TYPE: HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W MODULE WEIGHT:62.8 LBS MODULE DIMENSIONS:81.9" x 40.5" = 23.03SF UNIT WEIGHT OF AREA:2.15 PSF PV-2 1 LEGEND - VENT, ATTIC FAN (ROOF OBSTRUCTION) - ROOF ATTACHMENT - CONDUIT (N) GATEWAY (E) UTILITY METER (N) AC JUNCTION BOX UM (E) DISTRIBUTION PANEL BOX (DPB)DPB JB (N) AC DISCONNECTAC ROOF DESCRIPTION ROOF ROOF TILT AZIMUTH RAFTER SIZE RAFTER SPACING ROOF MATERIAL #1 16°270°2"X4"24" o.c.CLAY S TILE ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) TOTAL ROOF AREA (Sq. Ft.) TOTAL ROOF AREA COVERED BY ARRAY (%) #1 06 138 1454 10 TOTAL ROOF AREA COVERED BY ARRAY AREA (%) 138 1454 10 (E)FRONT YARD E CENTRAL AVE (E)BACK YARD (N) 3/4" ATTIC RUN (N) AC JUNCTION BOX (N) VISIBLE LOCKABLE LABELED FUSED AC DISCONNECT 30A, 208V, 3P, 3W, NEMA 3R, FUSED WITH 30A CLASS R FUSES (E) GRID TIED UTILITY METER WITH DISTRIBUTED PANEL BOARD 400A,208Y/120V, 3PH, 4W, NEMA 1 (WITH ATTACHED 1LPA 200A,208Y/120V, 3PH, 4W, NEMA 1) ROOF #1 (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W MODULES (N) APS ECU-C GATEWAY (N) IRONRDIGE XR-100 RAIL (02) APS QT2 -208 3-PHASE (208V) MICRO-INVERTERS (08) FJE-450 FASTJACK ATTACHMENTS @ 72" O.C. RO O F # 1 TI L T - 16 ° AZ I M . - 27 0 ° 36 INCH FIRE SETBACK 36 INCH FIRE SETBACK S H A L L A D A Y S T GATEWAY OUTLET (E) 1 LPA1LPA 542 E Central Ave - 101118106 & 20181990 4/25/2024 DP B UM AC GA T E W A Y JB 1LPA ROOF PLAN WITH STRING LAYOUT & BOM SCALE: 1/16" = 1'-0" SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-2A DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED STRING LAYOUT & BOM PV-2A 1 (E)BACK YARD BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 06 HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W MODULES INVERTER 02 APS QT2 -208 3-PHASE (208V) MICROINVERTER JUNCTION BOX 1 AC JUNCTION BOX, NEMA 3R, UL LISTED GATEWAY 1 APS ECU-C GATEWAY AC DISCONNECT 1 30A FUSED AC DISCONNECT,30A, 208V, 3P, 3W, NEMA 3R, FUSED WITH 30A CLASS R FUSES ATTACHMENT 8 FJE-450 FASTJACK ATTACHMENTS RAILS 4 IRONRDIGE XR-100 RAIL RAIL- 14 FEET (168") MID CLAMP 10 MODULES CLAMPS (MID CLAMPS) END CLAMP 4 MODULES CLAMPS ( END CLAMPS) GROUNDING LUG 1 GROUNDING LUG A- 1 A- 2 A- 3 (E)FRONT YARD E CENTRAL AVE - MODULE STRINGINGA S H A L L A D A Y S T A- 4 A- 5 A- 6 INVERTER-1A-1 A-3A-2 INVERTER-2A-4 A-6A-5 STRING NO:-1 542 E Central Ave - 101118106 & 20181990 4/25/2024 IRONRIDGE INTEGRATED GROUNDING & END/MID CLAMP (E) CLAY S TILE ROOF SURFACE PV MODULE (E) STRUCTURAL MEMBER FLASHED L-FOOT (1) 5/16"DIA. X 3" MIN. EMBEDMENT LAG SCREW AT EACH ATTACHMENT POINT INTO EXISTING FRAMING FASTJACK CHANNEL NUT FLASHING IRONRIDGE XR-100 RAIL 4-1/2" TALL FASTJACK E-SERIES (PART #FJE-450) SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-3 DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED ATTACHMENT DETAILS . PV-3 ATTACHMENT DETAIL (enlarged view) PV-3 SCALE: NTS 1 542 E Central Ave - 101118106 & 20181990 4/25/2024 06- HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W MODULES BRANCH 1 (02) APS QT2 -208 3-PHASE (208V) MICROINVERTERS AC BUS CABLE (N) JUNCTION BOX 600 V, NEMA 3R, UL LISTED G 2 L2 L1 G 1 L3 3 (N) AC DISCONNECT: 30A, 208V, 3P, 3W, NEMA 3R, FUSED WITH 30A CLASS R FUSES (3) 30A FUSES L2 L1 L2 L1 N N G G (N) VISIBLE LOCKABLE LABELED DISCONNECT L1 L2 L1 L2 L1 L2 30A/3P (E) 1 LPA (16.0 KVA) 200A, 208Y/120V, 3PH, 4W, NEMA 1 (10 KAIC) (E) MAIN BREAKER TO HOUSE 208 V, 100A/3P BACK FEED BREAKER AT THE OPPOSITE END OF THE MAIN BREAKER L3L3 L3 L3 L3 GATEWAY (N) APS ECU-C GATEWAY (N) FACTORY CORD TO (E) OUTLET IN ELECTRIC RM L1 L2 L3 NN L2 L1 L3 L1 L2 EXISTING GROUND ELECTRODE CONDUCTOR (E) DISTRIBUTED PANEL BOARD 400A, 208Y/120V, 3PH, 4W, NEMA 1 (10 KAIC) BI-DIRECTIONAL UTILITY 3-PH, 208Y/120V TO UTILITY GRID (E) MAIN BREAKER TO HOUSE 208 V, 400A/3P L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 (E) SPD (E) 1 LPA (18.3 KVA) (E) 2 LPA (54.3 KVA) EE E E 225A/3P 150A/3P SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-4 DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED ELECTRICAL LINE 1 ELECTRICAL LINE DIAGRAM PV-4 SCALE: NTS &CALCS. ID TYPICAL INITIAL CONDUCTOR LOCATION FINAL CONDUCTOR LOCATION CONDUCTOR CONDUIT # OF PARALLEL CIRCUITS CURRENT-CARRYING CONDUCTORS IN CONDUIT CONDUIT FILL PERCENT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT (A) MAX. CURRENT (A) BASE AMP. (A) DERATED AMP. (A) TERM. TEMP. RATING LENGTH VOLTAGE DROP 1 1 ARRAY JUNCTION BOX 10 AWG AC BUS CABLE -1 4 (L1,L2,L3)N/A N/A 10 AWG BARE COPPER 0.71 (53°C)N/A 9.6 12.00 N/A N/A 90°C 80FT 0.83% 2 1 JUNCTION BOX ACD 10 AWG THWN-2 COPPER MIN 0.75" Dia EMT 1 4 (L1,L2,L3)19.09%30A 10 AWG THWN-2, COPPER 0.94 (31°C)1 9.6 12.00 35 32.90 75°C 26FT 0.27% 3 1 ACD DPB 10 AWG THWN-2 COPPER MIN 0.75" Dia EMT 1 4 (L1,L2,L3)19.09%30A 10 AWG THWN-2, COPPER 0.94 (31°C)1 9.6 12.00 35 32.90 75°C 5FT 0.052% 120% RULE INTERCONCECTION 120% RULE - CEC 705.12(B)(3)(2) UTILITY FEED + SOLAR BACKFEED 100 A + 30 = 130A BUSS RATING x 120% 200 A x 120% = 240A 1.ALL GROUNDING ELECTRODES THAT ARE PRESENT AT EACH BUILDING OR STRUCTURE SHALL BE BONDED TOGETHER. (250.50) 2. HEIGHT OF CONDUIT FROM ROOFTOP SHALL BE 7/8". 3. SPLICES/WIRING TRANSITIONS FROM PV WIRE TO BUILDING WIRING TO OCCUR IN A LISTED WP JUNCTION BOX. 4. THE ARRAY EQUIPMENT GROUNDING CONDUCTOR SMALLER THAN 6 AWG, OR THE EQUIPMENT BONDING JUMPERS (IF USED) SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY RACEWAY OR CABLE ARMOR, INSTALLED IN HALLOW SPACES_ _INSIDE BUILDINGS OR OTHER METHODS AS PERMITTED IN SECTION 250.120(C). (690.46) 5. PV BACKFEED BREAKER TO BE INSTALLED AT OPPOSITE END OF BUSBAR OR INPUT FEEDER. 542 E Central Ave - 101118106 & 20181990 4/25/2024 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-4A DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-4A DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED SPECIFICATIONS PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 0.80 4-6 0.70 7-9 0.50 10-20 & INVERTER SPECIFICATIONS MANUFACTURER / MODEL APS QT2 -208 3-PHASE (208V) CONTINUOUS OUTPUT CURRENT 4.8A (208V) CALC. AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 2°C AMBIENT TEMP (HIGH TEMP 2%)31°C CONDUIT HEIGHT 0.5" ROOF TOP TEMP 90°C CONDUCTOR TEMPERATURE RATE 53°C MODULE TEMPERATURE COEFFICIENT OF VOC -0.27%/K SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W VMP 41.08V IMP 10.22A VOC 48.84V ISC 10.74A TEMP. COEFF. VOC -0.27%/K MODULE DIMENSION 81.9"(L) x 40.5"(W) PANEL WATTAGE 420W 542 E Central Ave - 101118106 & 20181990 4/25/2024 SIGNAGE ADHESIVE FASTENED SIGNS: · THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. · WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [CEC 110.21(B) FIELD MARKING]. · ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: POINT-OF-INTERCONCECTION OR AT MAIN SERVICE DISCONNECT (MSP) PER CODE: 2020 CEC 705.12(B)(3)(2) WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: MAIN SERVICE PANEL/AC DISCONNECT/INVERTER/ AC COMBINER 2020 CEC 690.13(B) ! WARINING PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: MAIN SERVICE PANEL/AC DISCONNECT 2020 CEC 690. 13(B) RATED AC OUTPUT CURRENT 9.6A NOMINAL OPERATING AC VOLTAGE 208 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: INVERTER AT OR WITHIN 3' OF THE DC COMBINER SWITCH 2020 CEC 690.56(C)(3) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM CAUTION! DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS 1 2 3 4 5 LABEL LOCATION: AC DISCONNECT 2020 CEC 690.56(C)(3) PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH LABEL LOCATION: MAIN SERVICE PANEL IF MSD IS OUTSIDE PLACE IT THERE / IF MSD IS INSIDE PLACE ON THE AC DISCONNECT 2020 CEC 690.56(C)(1)(a) LABEL LOCATION: MAIN SERVICE PANEL/AC DISCONNECT/AC COMBINER/ REVENUE METER 2020 CEC 705.12(B)(3) 7 LABEL LOCATION: DC CONDUIT EVERY 10' AND ON CONDUIT BODIES WHEN EXPOSED 2020 CEC 690.31(G)(D)(3) SERVICE DISCONNECT SECTIONNEUR PRINCIPALE SERVICIO DE DESCONEXION LABEL LOCATION: AC DISCONNECT 2020 CEC 230.66 9 6 8 PV SOLAR BREAKER PV ELECTRICAL EQUIPMENT LAYOUT LABEL LOCATION: BUILDING/STRUCTURE, (PER CODE: CEC 705.10 & 690.56(A)(B)) SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-5 DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED DP B UM AC GAT E W A Y S H A L L A D A Y S T E CENTRAL AVE 1LPA (N) APS ECU-C GATEWAY ROOFTOP PV MODULE (E) DPB TIED TO UTILITY METER WITH 1 LPA (N) FUSED AC DISCONNECT 542 E Central Ave - 101118106 & 20181990 4/25/2024 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-6 DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED EQUIPMENT SPECIFICATION 542 E Central Ave - 101118106 & 20181990 4/25/2024 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-7 DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED EQUIPMENT SPECIFICATION 542 E Central Ave - 101118106 & 20181990 4/25/2024 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-8 DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED EQUIPMENT SPECIFICATION 542 E Central Ave - 101118106 & 20181990 4/25/2024 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-9 DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED EQUIPMENT SPECIFICATION 542 E Central Ave - 101118106 & 20181990 4/25/2024 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS PV-9.1 DATE: 04/11/2024 54 2 E C E N T R A L A V E SA N T A A N A , CA 92 7 0 7 OL G - D E L H I Signature with Seal REVDATEDESCRIPTION REVISIONS (02) APS QT2 -208 3-PHASE (208V) SYSTEM INFO. (06) HANWHA Q.CELLS: Q.PEAK DUO L-G8.3/BFG 420W DC SYSTEM SIZE: 2.52 KWDC AC SYSTEM SIZE: 3.46 KWAC SPECTRA POWER SYSTEMS ADDRESS.:- 27892 CALLE SAN REMO, SAN JUAN CAPISTRANO, CA 92675 CONTACT NAME: KEN RILEY LICENSE NO.: #1063909 LICENSE CLASS.: C-10 KENR@SPECTRA-POWER.COM PHONE NO.: 7608159405 CONTRACTOR INFORMATION B02/02/2024AHJ REQUESTED PDF FORM FILLED EQUIPMENT SPECIFICATION 542 E Central Ave - 101118106 & 20181990 4/25/2024