HomeMy WebLinkAbout816 N Towner St #2 - PlanBldg# 101118924 APPROVALS: PLNG - ASevilla BLDG - CSG Consultants POLICE - BMartin 816 N Towner St #2 9/23/2024 816 N Towner St #2 9/23/2024 816 N Towner St #2 9/23/2024 816 N Towner St #2 9/23/2024 816 N Towner St #2 9/23/2024 816 N Towner St #2 9/23/2024 GENERAL NOTES 1.NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS TAKE PRECEDENCE OVER THESE STANDARD STRUCTURAL NOTES. DETAILS NOTES AS "TYPICAL DETAILS" SHALL BE USED WHENEVER APPLICABLE. REFER TO SPECIFICATIONS FOR INFORMATION NOT COVERED BY THESE NOTES OR DRAWINGS. 2.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS BEFORE STARTING WORK, AND THE ENGINEER/ARCHITECT SHALL BE NOTIFIED IMMEDIATELY, IN WRITING, OF ANY DISCREPANCIES. IN NO CASE SHALL DIMENSIONS BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THE STRUCTURAL DRAWINGS. 3.ALL OMISSIONS AND CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE STRUCTURAL DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION, AND RESOLVED WITH, THE ENGINEER BEFORE PROCEEDING WITH ANY WORK SO INVOLVED. 4.WHERE A CONSTRUCTION DETAIL IS NOT SPECIFICALLY SHOWN OR NOTES, THE DETAIL SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 5.THE CONTRACTOR SHALL DETERMINE THE LOCATION OF UTILITY SERVICES IN THE AREA TO BE EXCAVATED, BEFORE BEGINNING EXCAVATION. 6.NO PIPES, DUCTS, SLEEVES, CHASES, ETC. SHALL BE PLACED IN OR THROUGH SLABS, BEAMS, OR WALLS, NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC. EXCEPT AS INDICATED ON THE STRUCTURAL DRAWINGS. THE CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC. 7.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE 2022 CBC. 8.THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 9.RETAIN A CALIFORNIA REGISTERED CIVIL ENGINEER TO DESIGN ALL TEMPORARY BRACING, SHORING, AND SUPPORT REQUIRED DURING CONSTRUCTION. 10.INCLUDE ENGINEERING FEES, ENGINEERING DESIGN TIME AND BUILDING DEPARTMENT APPROVAL TIME IN THE COST OF PROPOSED MATERIAL ALTERNATIVES. CONTACT ENGINEER FOR FEE AMOUNT. SUBMIT MATERIAL ALTERNATIVE FOR REVIEW BEFORE CONSTRUCTION. DESIGN CRITERIA 1.VERTICAL LOADS (GRAVITY): a)DEAD LOADS: ROOF 15 PSF b)LIVE LOADS (REDUCIBLE UNLESS NOTED OTHERWISE): ROOF 20 PSF 2.LATERAL LOADS: a)EARTHQUAKE DESIGN DATA: V = 0.164 W (ASD) (INCLUDES RHO = 1.3) SEISMIC IMPORTANCE FACTOR =1 RISK CATEGORY =II MAPPED SPECTRAL RESPONSE ACCELERATIONS Ss 1.490 S1 0.530 SITE CLASS D SPECTRAL RESPONSE COEFFICIENTS Sds 1.170 Sd1 0.810 RESPONSE MODIFICATION FACTOR PLYWOOD SHEARWALLS R 6.5 SEISMIC RESPONSE COEFFICIENT Cs 0.181 ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE b)WIND: BASIC WIND SPEED 110 MPH SITE EXPOSURE B IMPORTANCE FACTOR 1.0 REBAR 1.NO BRICK OR POROUS MATERIAL SHALL BE USED TO SUPPORT FOOTING STEEL OFF THE GROUND. PRECAST CONCRETE ADOBES ARE APPROVED. 2.BAR REINFORCEMENT SHALL BE ASTM A615, GRADE 60. 3.BAR REINFORCEMENT THAT IS NOT WELDED SHALL BE ASTM A706, GRADE 60. WELDING OF REINFORCING BARS SHALL CONFORM TO AWS D1.4-92 AND CBC STANDARDS 19-1. E90XX ELECTRODES SHALL BE USED, SPECIAL INSPECTION IS REQUIRED FOR ALL FIELD WELDING. 4.SPLICES IN REINFORCING STEEL SHALL LAP AS FOLLOWS, UNLESS NOTES OTHERWISE: #3 THOUGH #6 =45 DIA., #7 TROUGH #11 = 56 DIA. HORIZONTAL SPLICES SHALL BE STAGGERED. NON-CONTACT SPLICES SHALL NOT BE SPACED TRANSVERSELY FARTHER APART 1 5 THE REQUIRED LAP SPLICE LENGTH, OR 6 INCHES. 5.THE CLEAR DISTANCE BETWEEN PARALLEL BARS SHALL BE FOUR BAR DIAMETERS BUT NO LESS THAN 11 2" U.O.N.. IN WALLS AND SLABS OTHER THAN THE CONCRETE JOIST CONSTRUCTION, BARS SHALL BE SPACED NOT FARTHER APART THAN THREE TIMES THE WALL OR SLAB THICKNESS, NOR 18 INCHES. 6.REINFORCING STEEL SHALL HAVE A PROTECTED CONCRETE COVERING AS FOLLOWS, U.O.N.: WALL BARS BELOW GRADE: ON DIRT SIDE WHEN POURED AGAINST DIRT =3" ON DIRT SIDE WHEN FORMED =2" WALL BARS ABOVE GRADE: FOOTING PADS =3" SLABS (ON EARTH)=2" SLABS (LIGHT WEIGHT CONCRETE)=3 4" SLABS (HARD ROCK CONCRETE)=1" JOISTS (SIDES, TOPS, & SOFFITS)=1" COLUMNS (TO MAIN STEEL)=2" BEAM, GIRDERS (SIDES, TOPS, & SOFFITS)= 2" IN ALL OTHER CASES =11 2" 7.WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 AND SHALL BE LAPPED 12 INCHES MINIMUM. 8.ALL WALLS SHALL BE DOWELED TO SUPPORTING FOOTINGS, BEAMS, PADS, ETC., WITH BARS THE SAME SIZE AND SPACING AS VERTICAL BARS IN THE WALL UNLESS OTHERWISE DETAILED. ANCHORAGE OF DOWELS SHALL BE EQUIVALENT OF A BAR SPLICE. 9.DOWEL REINFORCED SLABS TO WALLS AND OTHER EDGE MEMBERS PER TYPICAL DETAILS. 10.ALL REINFORCING STEEL IS TO BE PLACED IN A RELATIVE POSITION SHOWN ON DRAWINGS. NO SPLICES IN ANY REINFORCING WILL BE PERMITTED EXCEPT THOSE SHOWN ON THE STRUCTURAL DRAWINGS. 11.REINFORCING DETAILING, BENDING, AND PLACING SHALL BE ION ACCORDANCE WITH THE CONCRETE REINFORCING STEEL INSTITUTES "MANUAL OF STANDARD PRACTICE", LATEST EDITION. 12.ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS, AND INSERTS SHALL BE WELL SECURED IN THE POSITION WITH THE WIRE POSITIONERS BEFORE PLACING CONCRETE OR GROUT. VERTICAL BARS IN THE MASONRY WALLS SHALL BE TIED IN POSITION AT THE T&B AND INTERVALS NOT EXCEEDING 200 BAR DIAMETERS. SPECIAL INSPECTION 1.SPECIAL INSPECTION SHALL MEET THE REQUIREMENTS OF THE 2022 CBC SECTION 1704 & 1705. 2.SPECIAL INSPECTOR SHALL: A.BE UNDER THE SUPERVISION OF A CALIFORNIA REGISTERED ENGINEER. B.OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH APPROVED DRAWINGS AND SPECIFICATIONS. B.FURNISH INSPECTION REPORTS TO THE ENGINEER AND BUILDING DEPARTMENT. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION; THEN IF NOT CORRECTED, TO THE ENGINEER AND BUILDING DEPARTMENT. C.SUBMIT TO THE ENGINEER AND BUILDING DEPARTMENT A FINAL REPORT, SIGNED BY A CALIFORNIA REGISTERED CIVIL ENGINEER, STATING THAT THE WORK WAS IN CONFORMANCE WITH THE APPROVED DRAWINGS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CBC. 3.INSPECTION NOTES: A.CONSTRUCTION INSPECTIONS LISTED ARE IN ADDITION TO THE CALLED INSPECTIONS REQUIRED BY THE 2022 CBC SECTION 110. SPECIAL INSPECTION IS NOT A SUBSTITUTE FOR INSPECTION NY A BUILDING OFFICIAL, SPECIALLY INSPECTED WORK WHICH IS INSTALLED OR COVERED WITHOUT THE APPROVAL OF THE BUILDING OFFICIAL IS SUBJECT TO REMOVAL FOR EXPOSURE. B.CONTINUOUS INSPECTION IS ALWAYS REQUIRED DURING PERFORMANCE OF THE WORK UNLESS SPECIFICALLY NOTED. C.SPECIAL INSPECTORS MUST BE CERTIFIED BY THE BUILDING DEPARTMENT TO PERFORM THE TYPES OF INSPECTIONS SPECIFIED. D.IT IS THE RESPONSIBILITY OF THE OWNER TO INFORM THE SPECIAL INSPECTOR OR INSPECTION AGENCY AT LEAST ONE WORKING DAY BEFORE PERFORMING ANY WORK THAT REQUIRED SPECIAL INSPECTION. ALL WORK PERFORMED WITHOUT REQUIRED SPECIAL INSPECTION IS SUBJECT TO REMOVAL. 1.ANCHORS, ANCHOR BOLTS, & DOWELS A.VERIFY MANUFACTURERS INSTALLATION REQUIREMENTS (AND TESTING) OF EPOXIED DOWELS IN CONCRETE AT (HOLDOWNS) (EXISTING FOOTINGS) (CONCRETE REPAIRS). B.VERIFY MANUFACTURERS INSTALLATION REQUIREMENTS OF WEDGE AND SLEEVE ANCHORS (WHERE INDICATED). SPECIAL INSPECTION REQUIRED FOUNDATION 1.SOILS INFORMATION: BEARING PRESSURE = 1500 PSF (13 INCREASE FOR WIND OR SEISMIC) 2.BOTTOM OF FOOTING SHALL BE AT LEAST 24 INCHES BELOW THE LOWEST ADJACENT FINISHED GRADE INTO COMPETENT SOIL. 3.REFER TO AND CHECK WITH ARCHITECTURAL DRAWINGS FOR VARIOUS FLOOR SLOPES, DROPPED SLABS, DEPRESSIONS, CURBS, STEPS, WALKS DRAINS, DEPRESSED FLOOR, ETC. & DIMENSIONS NOT SHOWN. 4.NO CONCRETE SHALL BE POURED IN ANY FOUNDATION UNTIL EXCAVATION HAS BEEN INSPECTED, EXCAVATION SHALL BE KEPT FREE OF LOOSE MATERIAL AND STANDING WATER. 5.ALL SLEEVES THROUGH FOUNDATION WALLS AND UNDER FOOTING TO BE INSTALLED PRIOR TO FOUNDATION POUR. SEE TYPICAL DETAILS. 6.NO SLEEVING OF ANY GRADE BEAM WILL BE PERMITTED UNLESS SHOWN ON STRUCTURAL DRAWINGS APPROVED BY THE ENGINEER. 7.THE ENGINEER HAS NO CONTROL OR RESPONSIBILITY FOR THE DESIGN OF TEMPORARY SHORING, SCAFFOLDING, FORMING, UNDERPINNING, ETC., NOT DETAILED ON THESE PLANS. 8.ALL EXCAVATIONS SHALL BE PROPERLY BACKFILLED. DO NOT PLACE BACKFILL BEHIND RETAINING WALLS BEFORE CONCRETE (OR GROUT) HAS OBTAINED FULL DESIGN STRENGTH. CONTRACTOR SHALL BRACE OR PROTECT ALL BUILDING AND PIT WALLS BELOW GRADE FROM LATERAL LOADS UNTIL ATTACHING FLOORS ARE COMPLETELY IN PLACE AND HAVE ATTAINED FULL STRENGTH. CONTRACTOR SHALL PROVIDE FOR DESIGN, PERMITS, AND INSTALLATION OF SUCH BRACING. 9.CONTRACTOR SHALL COORDINATE ALL DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. NOTIFY STRUCTURAL ENGINEER, PRIOR TO FABRICATION OR ERECTION, WHEN DISCREPANCIES ARE FOUND. STRUCTURAL WOOD 1.ALL FRAMING LUMBER SHALL BE DOUGLAS FIR-LARCH GRADE MARKED BY A RECOGNIZED GRADING AGENCY (WCLIB 0R WWPA), VOLUNTARY STANDARD DOC PS20-25. LIGHT FRAMING CONSTRUCTION JOISTS & PLANKS No. 2 BEAMS & STRINGERS No. 1 POST AND TIMBERS No. 1 PARALLAM (PSL)2.0E WS (2900 Fb) PARALLAM (PSL)2.2E WS (2900 Fb) MICROLLAM (LVL)2.0E WS (2900 Fb) VERTICAL STUDS: 2x4 STUDS, 8'-0" LONG CONSTRUCTION GRADE 2x4 STUDS, 8'-1" TO 14'-0"No. 1 2x6 STUDS No. 2 ALL OTHER LUMBER No. 1 STRUCTURAL LIGHT FRAMING 2.ALL SILL PLATES RESTING ON CONCRETE OR MASONRY, WHICH IS IN CONTACT WITH EARTH OR RESTING ON FOUNDATIONS SHALL BE PRESSURE TREATED DOUGLAS FIR (PT.D.F.). ALL FASTENERS SUCH AS NAILS, BOLTS, SCREWS, ANCHOR BOLTS, ETC., ATTACHING P.T.D.F. OR FIRE-RETARDANT TREADED WOOD SHALL BE HOT-DIPPED ZINC COATED GALVANIZED OR STAINLESS STEEL (ASTM A153). 3.WHERE STUD PARTITIONS JOIN CONCRETE OR MASONRY WALLS, THE END STUD WALL SHALL BE ANCHORED THERETO WITH 1 2" (BOLTS NEAR THE TOP & BOTTOM AND AT EACH ROW OF TIRE BLOCKING. SUCH BOLTS SHALL BE EMBEDDED IN TH EWALL NOT LESS THAN 2 3 OF THE WALL THICKNESS OR 8" MAX). 4.CUTTING, NOTCHING, OR BORING OF STUDS SHALL BE PERMITTED ONLY AS DETAILED OR APPROVED BY ENGINEER AND/OR PER 2022 CBC TABLE 2308.5.9 OR 2308.5.10. 5.ALL NAILING SHALL CONFORM TO 2022 CBC TABLE 2304.10.1, AND SHALL BE COMMON NAILS, UNLESS NOTED OTHERWISE ON PLANS AND DETAILS. 6.ALL BOLY HEADS AND NUTS BEARING ON WOOD SHALL HAVE STANDARD CUT WASHERS. HOLES FOR BOLTS SHALL BE BORED 1 16" LARGER THAN THE NOMINAL DIAMETER. BOLTS IN THE WOOD SHALL NOT BE LESS THAN 7 DIAMETERS FROM THE END AND 4 DIAMETERS FROM THE EDGE OF THE MEMBER, 7.TOP PLATES OF ALL WOOD STUD WALLS TO BE 2-2x MINIMUM (SAME WIDTH AS STUDS), LAP 48" MIN. WITH NOT LESS THAN 6-16d NAILS AT EACH LAP AND NOT MORE THAN 12" BETWEEN NAILS. 8.PLYWOOD SHALL BE APA STRUCTURAL I RATED SHEATHING WITH EXTERIOR GLUE, PER DOC PS1 OR DOC PS2. 9.PROVIDE DOUBLED JOISTS UNDER ALL PARALLEL PARTITIONS. 10.ALL LAG SCREWS TO BE PREDRILLED, DRILL DIAMETER TO BE 40 TO 70 PERCENT OF THREADED SHANK DIAMETER AND FULL DIAMETER FOR SMOOTH SHANK PORTION. 11.RE-TIGHTEN ALL ANCHOR BOLTS JUST BEFORE CLOSING IN. 12.ALL FRAMING ANCHORS, POST CAPS, BASES, HANGERS, STRAPS, ETC. SHALL BE AS MANUFACTURED BY "SIMPSON COMPANY" OR ENGINEER APPROVED EQUAL. 13.PROVIDE BLOCKING OR BRIDGING PER 2021 NDS SECTION 4.4.1 & 2022 CBC SECTION 2308.4.6 AND SECTION 2308.5.7. 14.MOISTURE CONTENT OF WOOD AT TIME OF PLACING SHALL NOT EXCEED 19 PERCENT. 15.MACHINE BOLTS SHALL BE GRADE-A CONFORMING TO ASTM A307. ANCHOR BOLTS SHALL BE ASTM F1554, GRADE 36. NUTS FOR MACHINE BOLTS AND ANCHOR BOLTS SHALL CONFORM TO ASTM A563, HEX GRADE-A. THREADED RODS SHALL CONFORM TO ASTM A36. THREADED AND NUTTED ANCHOR BOLTS SHALL BE ASTM F1554, GRADE 36. ROUNDS WASHERS SHALL CONFORM TO ASTM F436. CONCRETE 1.CEMENT SHALL CONFORM TO ASTM C150, TYPE II. 2.AGGREGATES FOR NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C33. 3.CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,500 PSI AT 28 DAYS: (4"MAX. SLUMP FOR FLATWORK). MIN. COMPRESSIVE STRENGTH FOR WALLS TO BE 3,000 PSI MIN. COMPRESSIVE STRENGTH FOR GRADE BEAMS TO BE 3,000 PSI MIN. COMPRESSIVE STRENGTH FOR CAISSON TO BE 3,000 PSI 4.ADMIXTURES MAY BE USED WITH PRIOR APPROVAL OF THE ENGINEER. ADMIXTURES SHALL COMPLY WITH ASTM C494 & C107 AND BE OF A TYPE THAT INCREASES THE WORKABILITY OF THE CONCRETE, BUT SHALL NOT BE CONSIDERED TO REDUCE THE SPECIFIED MINIMUM CEMENT CONTENT (CALCIUM CHLORIDE SHALL NOT BE USED). 5.NO CONDUIT PLACED IN A CONCRETE SLAB SHALL HAVE AN OUTSIDE DIAMETER GREATER THAN 1 3 THE THICKNESS OF THE SLAB. NO CONDUIT SHALL BE EMBEDDED IN A SLAB THAT IS LESS THAN 31 2" THICK. EXCEPT FOR LOCAL OFFSETS, MINIMUM CLEAR DISTANCE BETWEEN CONDUITS SHALL BE THREE DIAMETERS ON CENTER (EXCEPT IF THE CONDUIT IS PASSING THROUGH). 6.PROJECTING CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC., SHALL BE FORMED WITH 3 4" CHAMFERS. 7.REFER TO DRAWINGS OF OTHER DISCIPLINES FOR MOLDS, GROOVES, CLIPS, ORNAMENTS, OR GROUNDS REQUIRED TO BE CAST IN CONCRETE. 8.ALL SLABS ON GRADE SHALL HAVE CONTROL JOINTS INSTALLED TO PROVIDE APPROXIMATELY 15 FOOT SQUARES UNLESS DETAILED OTHERWISE ON THE PLANS. WHERE CONCRETE POURS ARE STOPPED, THE JOINTS SHALL BE FORMED. SEE "TYPICAL SLAB-ON-GRADE JOINT DETAIL". 1. & 1705. 2. A. B. C. D. 3. A. B. C. D. I. A. B. C. II. A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. III. ANCHORS, ANCHOR BOLTS, & DOWELS A. B. C. IV. A. B. C. V. A. B. C. D. FOR SI: 1 INCH = 25.4 mm a.NAILS SPACED AT 6 INCHES AT INTERMEDIATE SUPPORTS WHERE SPANS ARE 48 INCHES OR MORE. FOR NAILING OF WOOD STRUCTURAL PANEL AND PARTICLEBOARD DIAPHRAGMS AND SHEARWALLS, REFER TO SECTION 2305. NAILS FOR WALL SHEATHING ARE PERMITTED TO BE COMMON, BOX OR CASING. b.SPACING SHALL BE 6 INCHES ON CENTER ON THE EDGE AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS FOR NONSTRUCTURAL APPLICATIONS. PANEL SUPPORTS AT 16 INCHES (20 INCHES IF STRENGTH AXIS IN THE LONG DIRECTION OF THE PANEL, UNLESS OTHERWISE MARKED). c.WHERE A RAFTER IS FASTENED TO AND ADJACENT PARALLEL CEILING JOIST IN ACCORDANCE WITH THIS SCHEDULE AND THE CEILING JOIST IS FASTENED TO THE TOP PLATE IN ACCORDANCE WITH THIS SCHEDULE, THE NUMBER OF TOENAILS IN THE RAFTER SHALL BE PERMITTED TO BE REDUCED BY ON NAIL. d.RSRS-01 IS A ROOF SHEATING RING SHANK NAIL MEETING THE SPECIFICATIONS IN ASTM F1667 e.TABULATE FASTENER REQUIREMENTS APPLY WHERE THE ULTIMATE DESING WIND SPEED IS LESS THAN 140 MPH. FOR WOOD STRUCTURAL PANEL ROOF SHEATING ATTACHED TO GABLE-END ROOF FRAMING AND TO INTERMEDIATE SUPPORTS WITHIN 48 INCHES OF ROOF EDGES AND RIDGES, NAILS SHALL BE SPACED AT 4 INCHES ON CENTER WHERE THE ULTIMATE DESING WIND SPEED IS GREATER THAN 130 MPH IN EXPOSURE B OR GREATER THAN 110 MPH IN EXPOSURE C. SPACING EXCEEDING 6 INCHES ON CENTER AT INTERMEDIATE SUPPORTS SHALL BE PERMITTED WHERE THE FASTENING IS DESIGNED PER THE AWC NDS. f.FASTENING IS ONLY PERMITTED WHERE THE ULTIMATE DESIGN WIND SPEED IS LESS THAN OR EQUAL TO 110 MPH. g.NAILS AND STAPLES ARE CARBON STEEL MEETING SPECIFICATIONS OF ASTM F1667. CONNECTIONS USING NAILS AND STAPLES OF OTHER MATERIALS, SUCH AS STAINLESS STEEL, SHALL BE DESIGNED BY ACCEPTABLE ENGINEERING PRACTICE OR APPROVED UNDER SECTION 104.11. DESCRIPTION OF BUILDING ELEMENTS 6d COMMON OR DEFORMED (2"x0.113"); OR 2 3/8"x0.113" NAIL (SUBFLOOR AND WALL) 8d BOX OR DEFORMED (2 1/2"x0.113"x 0.281" HEAD) (ROOF); OR RSRS-01 (2 3/8"x0.113") NAIL (ROOF)d 1 3/4" 16 GAGE STAPLE, 7/16" CROWN (SUBFLOOR AND WALL) 2 3/8"x0.113"x0.266 HEAD NAIL (ROOF) 1 3/4" 16 GAGE STAPLE, 7/16" CROWN ROOF 8d COMMON (2 1/2"x0.131"); OR DEFORMED (2"x0.113") (SUBFLOOR AND WALL) 8d COMMON OR DEFORMED (2 1/2"x0.131"x 0.281" HEAD) (ROOF) OR RSRS-01 (2 3/8"x0.113") NAIL (ROOF)d 2 3/8"x0.113"x0.266" HEAD NAIL OR 2" 16 GAGE STAPLE, 7/16" CROWN 10d COMMON (3"x0.148"); OR DEFORMED (2 1/2"x0.131"x0.281" HEAD) OTHER EXTERIOR WALL SHEATHING 1 1/2"X0.120 GALVANIZED ROOFING NAIL (7/16" HEAD DIAMETER); OR 1 1/4" 16 GAGE STAPLE WITH 7/16" OR 1" CROWN 1 3/4"x0.120 GALVANIZED ROOFING NAIL (7/16" DIAMETER HEAD); OR 1 1/2" 16 GAGE STAPLE WITH 7/16" OR 1" CROWN WOOD STRUCTURAL PANELS, COMBINATION SUBFLOOR UNDERLAYMENT TO FRAMING 8d COMMON (2 1/2"x0.131"); OR DEFORMED (2"x0.113"); OR DEFORMED (2"x0.120") 8d COMMON (2 1/2"x0.131"); OR DEFORMED (2 1/2"x0.131"); OR DEFORMED (2 1/2"x0.120") 10d COMMON (3"x0.148"); OR DEFORMED (2 1/2"x0.131"); OR DEFORMED (2 1/2"x0.120") PANELS SIDING TO FRAMING 6d CORROSION-RESISTANT SIDING (1 7/8" x0.106"); OR 6d CORROSTION-RESISTANT CASING (2"x0.099") 8d CORROSION-RESISTANT SIDING (2 3/8"x0.128"); OR 8d CORROSION-RESISTANT CASING (2 1/2"x0.113") 4d CASING (1 1/2"x0.080"); OR 4d FINISH ( 1 1/2"x0.072") 6d CASING (2"x0.099"); OR 6d FIINISH (2"x0.092"); OR (PANEL SUPPORTS AT 24 INCHES) 30.3/8" - 1/2" 31.19/32" - 3/4" 32.7/8" - 1 1/4" 33.1/2" FIBERBOARD SHEATHINGb 34.25/32" FIBERBOARD SHEATHINGb 35.3/4" AND LESS 36.7/8" - 1" 37.1 1/8" - 1 1/4" 38.1/2" OR LESS 39.5/8" 40.1/4" 41.3/8" EDGES (INCHES) INTERMEDIATE SUPPORTS (INCHES) WOOD STRUCTURAL PANELS (WSP), SUBFLOOR, ROOF AND INTERIOR WALL SHEATHING TO FRAMING AND PARTICIEBOARD WALL SHEATHING TO FRAMING SPACING AND LOCATION 2022 CBC: TABLE NO. 2304.10.2: FASTENING SCHEDULE, CONT. INTERIOR PANELING 6 6e 4 3f 3f 6 6e 4 6 3 3 6 6 6 6 6 6 6 12 6e 8 3f 3f 12 6e 8 12 6 6 12 12 12 12 12 12 12 NUMBER AND TYPE OF FASTENER 1.BLOCKING BETWEEN CEILING JOIST, RAFTERS OR TRUSSES TO TOP PLATE OR OTHER FRAMING BELOW BLOCKING BETWEEN RAFTERS OR TRUSS NOT AT THE WALL TOP PLATE, TO RAFTER OR TRUSS FLAT BLOCKING TO TRUSS AND WEB FILLER 2.CEILING JOISTS TO TOP PLATE 3.CEILING JOIST NOT ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITIONS (NO THRUST) (SEE SECTION 2308.7.3.1, TABLE 2308.7.3.1) 4.CEILING JOIST ATTACHED TO PARALLEL RAFTER (HEEL JOINT)(SEE SECTION 2308.7.3.1 TABLE 2308.7.3.1) 5.COLLAR TIE TO RAFTER 6.RAFTER OR ROOF TRUSS TO TOP PLATE (SEE SECTION 2308.7.5, TABLE 2308.7.5) 7.ROOF RAFTERS TO RIDGE VALLEY OR HIP RAFTERS; OR ROOF RAFTER TO 2-INCH RIDGE BEAM 8.STUD TO STUD (NOT AT BRACED WALL PANELS) 9.STUD TO STUD AND ABUTTING STUDS AT INTERSECTING WALL CORNERS ( AT BRACED WALL PANELS) 10.BUILT-UP HEADER (2" TO 2" HEADER) 11.CONTINUOUS HEADER TO STUD 12.TOP PLATE TO TOP PLATE 13.TOP PLATE TO TOP PLATE, AT END JOINTS 14.BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (NOT AT BRACED WALL PANELS) 15.BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING AT BRACED WALL PANELS 16.STUD TO TOP OR BOTTOM PLATE 17.TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS 18.1" BRACE TO EACH STUD AND PLATE 19.1"x6" SHEATHING TO EACH BEARING 20.1"x8" AND WIDER SHEATHING TO EACH BEARING 21.JOIST TO SILL, TOP PLATE, OR GIRDER 22.RIM JOIST, BAND JOIST, OR BLOCKING TO TOP PLATE, SILL OR OTHER FRAMING BELOW 23.1"x6" SUBFLOOR OR LESS TO EACH JOIST 24.2" SUBFLOOR TO JOIST OR GIRDER 25.2" PLANKS (PLANK & BEAM-FLOOR & ROOF) 26.BUILT-UP GIRDERS AND BEAMS, 2" LUMBER LAYERS 27.LEDGER STRIP SUPPORTING JOISTS OR RAFTERS 28.JOIST TO BAND JOIST OR RIM JOIST 29.BRIDGING OR BLOCKING TO JOIST, RAFTER OR TRUSS 4-8d BOX (2 1/2"x 0.113"); OR 3-8d COMMON (2 1/2"x 0.131"); OR 3-10d BOX (3"x 0.128"); OR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES 7/16" CROWN 2-8d COMMON (2 1/2"x 0.131") 2-3"x 0.131" NAILS 2-3" 14 GAGE STAPLES 2-16d COMMON (3 1/2"x 0.162") 3-3"x 0.131" NAILS 3-3" 14 GAGE STAPLES 16d COMMON (3 1/2"x 0.162") @ 6" O.C. 3"x 0.131" NAILS @ 6" O.C. 3"x 14 GAGE STAPLES @ 6" O.C. 4-8d BOX (2 1/2"x 0.113"); OR 3-8d COMMON (2 1/2"x 0.131"); OR 3-10d BOX (3"x 0.128"); OR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES 7/16" CROWN 3-16d COMMON (3 1/2"x 0.162"); OR 4-10d BOX (3"x 0.128"); OR 4-3"x 0.131" NAILS; OR 4-3" 14 GAGE STAPLES 7/16" CROWN PER TABLE 2308.7.3.1 3-10d COMMON (3"x 0.148"); OR 4-10d BOX (3"x 0.128"); OR 4-3"x 0.131" NAILS; OR 4-3" 14 GAGE STAPLES 7/16" CROWN 3-10d COMMON (3"x 0.148"); OR 3-16d BOX (3 1/2"x 0.135"); OR 4-10d BOX (3"x 0.128"); OR 4-3"x 0.131" NAILS; OR 4-3" 14 GAGE STAPLES 7/16" CROWN 2-16d COMMON (3 1/2"x 0.162"); OR 3-16d BOX (3 1/2"x 0.135"); OR 3-10d BOX (3"x 0.128"); OR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES 7/16" CROWN OR 3-10d COMMON (3 1/2"x 0.148"); OR 4-16d BOX (3 1/2"x 0.135"); OR 4-10d BOX (3"x 0.128"); OR 4-3"x 0.131" NAILS; OR 4-3" 14 GAGE STAPLES, 7/16" CROWN 16d COMMON (3 1/2"x 0.162"); 10d BOX (3"x 0.128"); OR 3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES, 7/16" CROWN 16d COMMON (3 1/2"x 0.162"); OR 16d BOX (3 1/2"x 0.135"); OR 3"x0.131" NAILS; OR 3-3" 14 GAGE STAPLES, 7/16" CROWN 16d COMMON (3 1/2"x 0.162"); 16d BOX (3 1/2"x 0.135") 4-8d COMMON (2 1/2"x0.131"); OR 4-10d BOX (3"x0.128") 5-8d BOX (2 1/2"x0.113") 16d COMMON (3 1/2"x 0.162"); 10d BOX (3"x 0.128"); OR 3"x 0.131" NAILS; OR 3" 14 GAGE STAPLES, 7/16" CROWN 8-16d COMMON (3 1/2"x 0.162"); OR 12-16d BOX (3 1/2"x 0.135"); OR 12-10d BOX (3"x 0.128"); OR 12-3"x 0.131" NAILS; OR 12-3" 14 GAGE STAPLES 7/16" CROWN 16d COMMON (3 1/2"x 0.162"); 16d BOX (3 1/2"x 0.135"); OR 3"x 0.131" NAILS OR 3" 14 GAGE STAPLES, 7/16" CROWN 2-16d COMMON (3 1/2"x 0.162"); OR 3-16d BOX (3 1/2"x 0.135"); OR 4-3"x 0.131" NAILS; OR 4-3" 14 GAGE STAPLES, 7/16" CROWN 3-16d BOX (3 1/2"x 0.135"); OR 4-8d COMMON (2 1/2"x 0.131"); OR 4-10d BOX (3"x 0.128"); OR 4-3"x 0.131" NAILS; OR 4-8d BOX (2 1/2"x 0.113"); OR 4-3" 14 GAGE STAPLES, 7/16" CROWN OR 2-16d COMMON (3 1/2"x 0.162"); OR 3-16d BOX (3 1/2"x 0.135"); OR 3-10d BOX (3"x 0.128"); OR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES, 7/16" CROWN 2-16d COMMON (3 1/2"x 0.162"); OR 3-10d BOX (3"x 0.128"); OR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES, 7/16" CROWN 3-8d BOX (2 1/2"x 0.113"); OR 2-8d COMMON (2 1/2"x 0.131"); OR 2-10d BOX (3"x 0.128"); OR 2-3"x 0.131" NAILS; OR 2-3" 14 GAGE STAPLES, 7/16" CROWN 3-8d BOX (2 1/2"x 0.113"); OR 2-8d COMMON (2 1/2"x 0.131"); OR 2-10d BOX (3"x 0.128"); OR 2-1 3/4" 16 GAGE STAPLES, 1" CROWN 3-8d COMMON (2 1/2"x 0.131"); OR 3-8d BOX (2 1/2"x 0.113"); OR 3-10d BOX (3"x 0.128"); OR 3-1 3/4" 16 GAGE STAPLES, 1" CROWN WIDER THAN 1"x8" 3-8d COMMON (2 1/2"x 0.131"); OR 4-8d BOX (2 1/2"x 0.113"); OR 3-10d BOX (3"x 0.128"); OR 4-1 3/4" 16 GAGE STAPLES, 1" CROWN FLOOR 4-8d BOX (2 1/2"x 0.113"); OR 3-8d COMMON (2 1/2"x 0.131"); OR FLOOR 3-10d BOX (3"x 0.128"); OR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES, 7/16" CROWN 8d BOX (2 1/2"x 0.131") 8d COMMON (2 1/2"x 0.131"); OR 10d BOX (3"x 0.128"); OR 3"x 0.131" NAILS; OR 3" 14 GAGE STAPLES, 7/16" CROWN 3-8d BOX (2 1/2"x 0.113"); OR 2-8d COMMON (2 1/2"x 0.131"); OR 3-10d BOX (3"x 0.128"); OR 2-1 3/4" 16 GAGE STAPLES, 1" CROWN 3-16d BOX (3 1/2"x 0.135"); OR 2-16d COMMON (3 1/2"x 0.162") 3-16d BOX (3 1/2"x 0.135"); OR 2-16d COMMON (3 1/2"x 0.162") 20d COMMON (4"x0.192") 10d BOX (3"x 0.128"); OR 3"x 0.131" NAILS; OR 3" 14 GAGE STAPLES, 7/16" CROWN AND: 2-20d COMMON (4"x 0.192"); OR 3-10d BOX (3"x 0.128"); OR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES, 7/16" CROWN 3-16d COMMON (3 1/2"x 0.162"); OR 4-16d BOX (3 1/2"x 0.135"); OR 4-10d BOX (3"x 0.128"); OR 4-3"x 0.131" NAILS; OR 4-3" 14 GAGE STAPLES, 7/16" CROWN 3-16d COMMON (3 1/2"x 0.162"); OR 4-10d BOX (3"x 0.128"); OR 4-3"x 0.131" NAILS; OR 4-3" 14 GAGE STAPLES, 7/16" CROWN 2-8d COMMON (2 1/2"x 0.131"); OR 2-10d BOX (3"x 0.128"); OR 2-3"x 0.131" NAILS; OR 2-3" 14 GAGE STAPLES, 7/16" CROWN EACH END, TOENAIL EACH END, TOENAIL END NAIL FACE NAIL EACH JOIST, TOENAIL FACE NAIL FACE NAIL FACE NAIL END NAIL TOENAIL 24" O.C. FACE NAIL 16" O.C. FACE NAIL 16" O.C. FACE NAIL 12" O.C. FACE NAIL 16"O.C. EA EDGE, FACE NAIL 12"O.C. EA EDGE, FACE NAIL TOENAIL 16" O.C. FACE NAIL 12" O.C. FACE NAIL EACH SIDE OF END JOINT, FACE NAIL (MINIMUM 24" LAP SPLICE LENGTH EACH SIDE OF END JOINT) 16" O.C. FACE NAIL 12" O.C. FACE NAIL 16" O.C. FACE NAIL TOENAIL END NAIL FACE NAIL FACE NAIL FACE NAIL FACE NAIL TOENAIL 4" O.C. TOENAIL 6" O.C. TOENAIL FACE NAIL BLIND AND FACE NAIL EACH BEARING, FACE NAIL 32"O.C.,FACE NAIL AT TOP & BOT. STAGG. ON OPP. SIDES 24"O.C.,FACE NAIL AT TOP & BOT. STAGG. ON OPP. SIDES ENDS AND AT EACH SPLICE, FACE NAIL EACH JOIST OR RAFTER, FACE NAIL END NAIL EACH END, TOENAIL NUMBER AND TYPE OF FASTENERg SPACING AND LOCATION 2 TOENAILS ON ONE SIDE AND 1 TOENAIL ON OPPOSITE SIDE OF RAFTERS OR TRUSS 2022 CBC: TABLE NO. 2304.10.2: FASTENING SCHEDULE DESCRIPTION OF BUILDING ELEMENTS ROOF WALL 8 1 6 N T O W N E R S T . GA R A G E T O A D U 81 6 N T O W N E R S T . SA N T A A N A , C A 9 2 7 0 3 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @rsi.plans www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.24-347 DATE:8/1/24 RAMIREZ STRUCTURAL INC STRUCTURAL NOTES S1.0 816 N Towner St #2 9/23/2024 STRUCTURAL ABBREVATIONS A.B.ANCHOR BOLT ABV.ABOVE ADD'L ADDITIONAL ADJ.ADJACENT ALUM.ALUMINUM ALT.ALTERNATE APPRX.APPROXIMATE(LY) ARCH.ARCHITECT(TURAL) &AND @ AT BEL.BELOW B.F.BRACED FRAME BLDG.BUILDING BLK.BLOCK BLKG.BLOCKING BM.BEAM B.N. BOUNDARY NAILING BNDRY.BOUNDARY B.O.F.BOTTOM OF FOOTING BRDG.BRIDGE(ING) BRG.BEARING BTM.BOTTOM BTWN.BETWEEN CAMB.(C)CAMBER(ED) CANT.CANTILEVERED C.F.CUBIC FEET(FOOT) C.G.CENTER OF GRAVITY C.I.P.CAST IN PLACE C.J.CONSTRUCTION JOINT CL.CENTER LINE CLG.CEILING CLR.CLEAR CMU.CONC. MASONRY UNIT COL.COLUMN CONC.CONCRETE CONN.CONNECTION CONST.CONSTRUCTION CONT.CONTINUOUS CTSK.COUNTERSINK CTR.CENTER(ED) C.Y.CUBIC YARD d PENNY(NAILS) DBL.DOUBLE DEPT.DEPARTMENT D.F.DOUGLAS FIR DIA. ()DIAMETER DIAG.DIAGONAL DIAPH.DIAPHRAGM DIM.DIMENSION DN.DOWN do DITTO(REPEAT) DP (D)DEEP (DEPTH) DWG.DRAWING(S) DWL.DOWEL(S) EA.EACH E.F.EACH FACE E.J.EXPANSION JOINT EL.ELEVATION ELEC.ELECTICAL ELEV.ELEVATOR EMBD.EMBED(MENT) E.N.EDGE NAIL/SCREWS ENG.ENGINEER ES.EDGE SCREWS EQ.EQUAL EQPT.EQUIPMENT EXP.EXPANSION EXST.(E)EXISTING EXT.EXTERIOR FAB.FABRICATION FND.FOUNDATION FIN.FINISH(ED) FLG.FLANGE FLR.FLOOR F.N.FIELD(FACE)NAIL F.O.C.FACE OF CONCRETE F.O.M.FACE OF MASONRY F.O.S.FACE OF STUD F.O.W.FACE OF WALL FRM.FRAME(ING) F.S.FAR SIDE FT.(')FOOT(FEET) FTG.FOOTING GA.GAUGE GALV.GALVANIZED GB GRADE BEAM GLB GLUED LAMINATED BEAM GRD.GRADE GYPDB.GYPSUM WALLBOARD HD HOLD DOWN HDR.HEADER HGR.HANGER HORZ.(H)HORIZONTAL HSB HIGH STRENGTH HT.HEIGHT I.D.INSIDE DIAMETER I.E. INVERT ELEVATION I.F.INSIDE FACE IN.()INCH(S) INT.INTERIOR JST.JOIST JT.JOINT K KIPS () LAT.LATERAL LB(#)POUNDS L.B.LAG BOLTS LDGR LEDGER L.F.LINEAL FEET(FOOT) LG.LONG(ITUDINAL) LGTH LENGTH LLH LONG LEG HORIZ. LLV LONG LEG VERT. LT.WT.LIGTH WEIGHT MAS.MASONRY MAT'L.MATERIAL MAX.MAXIMUM M.B.MACHINE BOLT MECH.MECHANICAL MEZZ.MEZZANINE MFR.MANUFACTURER MISC.MISCELLANEOUS MIN.MINIMUM MLB MINI-LAM-BM. MTL.METAL (N)NEW NO. (#)NUMBER N.S.NEAR SIDE N.S.G.NON-SHRINK GROUT N.T.S.NOT TO SCALE O.C.ON CENTER O.D.OUTSIDE DIAMETER O.D.OUTSIDE DIAMETER O.F.OUTSIDE FACE O.H. OPPOSITE HAND OPNG.OPENING ORNT. ORIENTATE(ION) OWJ.OPEN WEB JOISTS PAR. (//)PARALLEL P/C PRECAST CONCRETE PERP. (┴)PERPENDICULAR PL.(PL)PLATE PLAM PURLAM BEAM PLY.PLYWOOD P.S.F.POUNDS PER SQUARE FOOT P.S.I.POUNDS PER SQUARE INCH P.T.PRESSURE TREATED P/T POSTTENSIONED (PRESTRESSED) QTY.QUANTITY RAD.(R)RADIUS R.C.P.REINFORCED CONCRETE PIPE REF.REFERENCE REINF.REINFORCEMENT(ING) REQ'D.REQUIRED R.F.RIGID FRAME R.O.ROUGH OPENING R.B.RIDGE BOARD SCHED.SCHEDULE SHT.SHEET SHTG.SHEATHING SIM.SIMILAR SKW.SKEW(ED) SPC.SPACE(S)(ING) SPEC.SPECIFICATION(S) SQ.SQUARE SS SELECT STRUCTURAL STD.STANDARD STGR.STAGGER(ED) STIFF.STIFFENER(S) STIR.STIRRUP(S) STL.STEEL STRUC.STRUCTURAL SUSP.SUSPENDED(TION) SYMM.SYMMETRICAL (T)TOP T & B TOP AND BOTTON TEMP.TEMPERATURE T & G TONGUE AND GROOVE THK.THICK(NESS) THRD.THREADED TMPRY.TEMPORARY T.N.TOE NAIL T.O.S.TOP OF SHEATHING T.O.W.TOP OF WALL TRANSV.TRANSVERSE T.S.TOP OF STEEL TYP.TYPICAL UBC UNIFORM BUILDING CODE U.O.N.UNLESS OTHERWISE NOTED VERT.VERTICAL VIF VERIFY IN FIELD (W)WIDE(WIDTH) /WITH WD.WOOD W.P.WORK POINT WPJ WEAKENED PLANE JOINT W.S.WELDED STUD(S) WT WEIGHT WWF WELDED WIRE FABRIC X-STG EXTRA STRONG XX-STG DOUBLE EXTRA STRONG YD YARD 1704 DRAWINGS DEPARTMENT. THE AND BY IN THE INSPECTIONS SUBSTITUTE IS IS THE TO OR WORK REQUIRED SOIL ALL BEFORE CAST-IN-PLACE BEAMS WALLS ON AND CONCRETE CORES. VERIFY PLACEMENT AND COMPRESSIVE STRENGTH OF CONCRETE IN TILT-UP PANELS STRUCTURAL CONCRETE CONCRETE INSULATING NOT CONCRETE SPECIAL EPOXIED SLEEVE AND (WHERE OF IS IS IS CONCRETE APPROVED STEEL CHECK CONTINUOUS 8 1 6 N T O W N E R S T . GA R A G E T O A D U 81 6 N T O W N E R S T . SA N T A A N A , C A 9 2 7 0 3 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @rsi.plans www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.24-347 DATE:8/1/24 RAMIREZ STRUCTURAL INC STRUCTURAL NOTES S1.1 816 N Towner St #2 9/23/2024 1.REFER TO STRUCTURAL NOTES ON SHEET S1.0 AND TYPICAL DETAILS ON SHEETS S3.0-S3.3. THESE NOTES AND DETAILS SHALL BE USED WHERE APPLICABLE WHETHER SPECIFICALLY REFERENCED ON PLANS OR NOT. 2.CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES WITH STRUCTURAL REQUIREMENTS INDICATED. REFER TO ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS. 3.REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 4.NON-STRUCTURAL ELEMENTS IN NATURE SUCH AS DRAINS, SUMPS, EXTERIOR HARDSCAPE, MECHANICAL UNITS, ETC., ARE TO BE DESIGNED BY OTHERS. 5.STRUCTURAL WALLS ARE WALLS THAT RESIST GRAVITY, WIND, AND/OR SEISMIC LOADS. ALL EXTERIOR WOOD FRAMED WALLS ARE STRUCTURAL WALLS. WALLS OR PORTIONS NOT INDICATED ON THE STRUCTURAL DRAWINGS ARE PARTITION WALLS. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION AND EXTENT OF PARTITION WALLS. 6.FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. FIELD-CUT ENDS, NOTCHED, AND BORINGS SHALL BE FIELD-TREATED. FASTENERS IN TREATED WOOD SHALL BE APPROVED SILICON BRONZE/COPPER, STAINLESS STEEL, OR HOT-DIPPED ZINC COATED STEEL. 7.ALL WOOD FRAMED STRUCTURAL WALLS ARE TO BE 2x4 STUDS @ 16" O.C., U.O.N. (USE 2x6 STUDS @ 16" O,C, AT PLUMBING WALLS). 8.ANCHOR BOLTS AT STRUCTURAL WALLS REQUIRE A PLATE WASHER WITH MINIMUM SIZE OF 0.299"x3"x3". 9.ANCHOR BOLTS AND HOLDOWN ANCHORS, SHALL BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION. 10.SHEAR WALL SHEATHING SHOWN ON ONE SIDE MAY ALTERNATIVELY BE SHEATHED ON THE OPPOSITE SIDE OF THE WALL. 11.EXTREME CARE SHOULD BE TAKEN WHEN DOING FOUNDATION WORK WITH POST-TENSIONED SLABS (WHERE APPLICABLE). NO TENDONS SHALL BE DAMAGED OR CUT. NOTIFY THE ENGINEER OF RECORD PRIOR TO ANY DRILLING, CORING, SAQ-CUTTING, ETC. USE NON-DESTRUCTIVE METHODS TO LOCATE TENDONS PRIOR TO ANY WORK. 12.IF ADVERSE SOILS CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION MAY BE REQUIRED. SPREAD FOOTING PER SCHEDULE ON THIS SHEET2.0 WOOD POST SIZE. MARK IS INDICATED AT THE BASE OF THE POST SHEAR WALL POST AND HARDWARE MODEL SEE DETAIL 1/S3.1 FOR INSTALLATION DETAILS 0'-00" 6 WOOD SHEARWALL. SEE SHEARWALL SCHEDULE ON S2.0 FOR ASSEMBLY AND DETAIL REFERENCES. SHEARWALLS STARTS AT FOUNDATION AND CONTINUES UP TO ROOF LEVEL (E) CONCRETE FOOTING, INDICATED WITH DASHED LINES 4x4 HDU2 SCALE: = 1'-0" N FOUNDATION PLAN 1/4"SCALE: = 1'-0" N ROOF FRAMING PLAN 1/4" 4x4 POST PLAN NOTES LEGEND TYPE SHEATHING (1) 15 32 STRUC 1 O.S. NAIL SIZE (2) EDGE & FIELD NAIL SPACING 10d 6" & 12" 0'-00" 6 SILL TO WOOD CONN. SDS1 4"x6" @ 16" SILL TO CONC. CONN. 2x:5 8" DIA. A.B. @32" 3x:5 8" DIA. A.B. @48" ALLOW SHEAR (PLF) 312 SHEAR WALL TYPE (3) I 15 32 STRUC 1 O.S. 10d 4" & 12" 0'-00" 4 SDS1 4"x6" @ 12" 3x:5 8" DIA. A.B. @32"469 II 15 32 STRUC 1 O.S. 10d 3" SGRD. & 12" (4)0'-00" 3 SDS1 4"x6" @ 9" 3x:5 8" DIA. A.B. @24"611 II 15 32 STRUC 1 O.S. 10d 0'-00" 2 SDS1 4"x6" @ 6" 3x:5 8" DIA. A.B. @16"745 II 15 32 STRUC 1 D.S. 10d 0'-00" 4D SDS1 4"x6" @ 6" 3x:5 8" DIA. A.B. @16"938 III 15 32 STRUC 1 D.S. 10d 0'-00" 3D SDS1 4"x6" @ 4" 3x:5 8" DIA. A.B. @12"1223 IV 15 32 STRUC 1 D.S. 10d 0'-00" 2D SDS1 4"x6" @ 3" 3x:5 8" DIA. A.B. @8"1600 IV 2" SGRD. & 12" (4) 4" & 12" 3" SGRD. & 12" (4) 2" SGRD. & 12" (4) NOTES: 1.O.S. INDICATES SHEATHING ON ONE SIDE OF THE WALL. D.S. INDICATES SHEATHING ON BOTH SIDES OF THE WALL. 2.USE COMMON WIRE NAILS FOR ALL STRUC 1 SHEATHING 3.SEE DETAIL 5/S3.1 & 9/S3.1 FOR ALL SHEARWALL ASSEMBLIES BASED ON SHEAR WALL TYPE 4.FOR STAGGERED EDGE NAIL REQUIREMENTS SEE DETAILS 5/S3.1 & 9/S3.1 SHEARWALL SCHEDULE EXISTING ROOF FRAMING DOOR OR WALL INFILL PER DETAIL TYP. @ DIAGONAL HATCH 1 S3.2 PROVIDE RED-GARD WATER PROOFING (ICC#ESR-1413) OVER SELF LEVELING CONCRETE OVER EXISTING CONCRETE SLAB EXISTING CONC. SLAB S3.0 1TYP. SLAB ON GRADE: 4" THICK CONC. SLAB w/ #3 BARS @ 18" O.C. AT CENTER OF SLAB, EA. WAY. OVER 2" OF SAND, OVER COMPETENT SOIL 14'-10" 8' - 5 " 6 6 6 8'-0" 21 ' - 0 " 6 CRIPPLE WALL SUPPORT FROM CEILING FRAMING TO ROOF FRAMING EXISTING 2x4 WALL STUD TO BE FIELD VERIFIED EXISTING 1'-0" WIDE CONT. FOOTING TO BE FIELD VERIFIED TYPICAL 2x 1 0 C . J . @ 1 6 " O . C . 4x 6 4x6 4x6 4x6 4x 6 4x6 4x6 2x6 RAFTERS @ 24" O.C. 5 S4.0 5 S4.0 1 S4.0 5 S4.0 1 S5.0 3 S5.0 2 S5.0 4x4 HDU2 4x4 HDU2 4x4 HDU2 4x4 HDU2 4x4 HDU2 4x4 HDU2 4x4 HDU2 4x4 HDU2 6 S4.0 6 S4.0 6 S4.0 3 S4.0 3 S4.0 6 S4.0 6 S4.0 6 S4.0 2 S5.0 4 S5.0 7 S3.2 4x4 POST FRAMING MEMBER BEARING ON TOP OF TOP PLATES FRAMING MEMBER HUNG AT IT'S SUPPORT HEADER MEMBER INSTALLED PER DETAIL 8/S3.2 6 REQUIRED TOP PLATE SPLICE. SEE SCHEDULE ON 7/S3.1 FOR ALL REQUIREMENTS. THE MARKED SPLICE SHALL APPLY FOR THE FULL LENGTH OF THE WALL. USE TYPE SPLICE MIN., UNLESS OTHERWISE NOTED.6 3 S3.2 TYP. 7 S4.0 8 1 6 N T O W N E R S T . GA R A G E T O A D U 81 6 N T O W N E R S T . SA N T A A N A , C A 9 2 7 0 3 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @rsi.plans www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.24-347 DATE:6/10/24 RAMIREZ STRUCTURAL INC ROOF/ FOUNDATION PLAN S2.0 816 N Towner St #2 9/23/2024 AT INTERIOR t/ 3 t = S L A B T H I C K N E S S (P E R P L A N ) 1/8" WEAKENED PLANE JOINT: SAWCUT SLAB AS SOON AS POSSIBLE AFTER POUR (AVOID SPALLING CORNERS) REINF. PER PLAN CLEAN GRAVEL PER PLAN VAPOR BARRIER PER PLAN PAD GRADE AT GARAGE/EXTERIOR t/ 3 t = S L A B T H I C K N E S S (P E R P L A N ) 1/8" WEAKENED PLANE JOINT: SAWCUT SLAB AS SOON AS POSSIBLE AFTER POUR (AVOID SPALLING CORNERS) REINF. PER PLAN SAND PER PLAN PAD GRADE 1 1 9"3" MIN MI N 4"MI N 134 578 91112 SLAB ON GRADE STEP IN SLAB 18" SLAB EDGE 8" MI N . 12" MIN. FINISH GRADE TURN TRANSVERSE REINF. & PROVIDE DOUBLE CONT. REINF. AT EDGE PARTITION WALL ANCHORAGE SLAB PER PLAN P.T.D.F. SILL PLATE PER PLAN w/ HILTI'S 0.145" DIA. x 3" LONG POWER DRIVEN PINS @ 32" O.C. w/ 1 5 8 " WASHER 1 1 4 " MIN. CONCRETE PENETRATION PARTITION WALL FRAMING PER PLAN SHOT PINS SLAB PER PLAN 1 2" DIA. HEADED A.B's @ 48" O.C. MAX. PARTITION WALL FRAMING PER PLAN ANCHOR BOLT AT CURB 6" #3 CONT. STEPPING CONTINUOUS FOOTINGFOOTING AT PIPE/CONDUIT REINFORCEMENT HOOKS & BENDSTIES & STIRRUPS STEP DOWNSTEP UP FOOTING INTERSECTIONS ENDINTERSECTIONCORNER PLATE SPLICE FIX DETAIL STUD OCCURS OVER BOLT 30 BAR DIA. 30 BAR DIA. 3" C L R . TOP REINF. CONT. THRU OPTIONAL C.J. REINF. SAME SIZE & SPACING AS FOOTING REINF. 30 BAR DIA. 3" C L R . FOOTING STEP AS REQD.2x RISE 3" M I N . 2' - 0 " MA X . RI S E 30 BAR DIA. 30 BAR DIA. 2" C L R . 3" C L R . 3"CL R 2x RISE 2' - 0 " MA X . RI S E FOOTING STEP AS REQD.30 BAR DIA. 3" C L R . 'D ' 2' - 0 " MA X . RI S E REINF. SAME SIZE & SPACING AS FOOTING REINF. TOP BARS (WHERE OCCURS) 2x RISE 6" MIN 'D 'MIN 2 #5 U.O.N. STD. HOOK 30 DIA. U.O.N. 2'-0" MIN. TYP. 30 DIA. U.O.N. 2'-0" MIN. TYP. ALL CORNERS & INTERSECTIONS SHALL HAVE 2 #5 VERTICAL U.O.N. PROVIDE OUTSIDE CORNER LAP BARS PROVIDE STD. 90° HOOK AT INSIDE BARS NOTE: PLACE CONCRETE FILL AROUND SLEEVES BEFORE POURING FOOTING PADS. FILL SHALL BE SAME WIDTH AS FOOTING AND FULL DEPTH OF PIPE TRENCH. NOTE: WHERE PIPES ARE MORE THAN 2'-0" BELOW OF FOOTING. STEP FOOTING DOWN PER TYPICAL FOOTING STEP DETAILBACKFILL TRENCH AND RECOMPACTION TO 90 PERCENT COMPACTION NO DIGGING FOR PIPE TRENCH PARALLEL TO FOOTING BELOW THIS LINE (STEP FTG. DOWN AS REQ'D) TRENCH FOOTING 1'-6" MIN 30 ° NO PIPES TO BE PLACED WITHIN THIS HEIGHT 2' - 0 " MA X . 9" MIN. SLEEVE: I.D. SLEEVE SHALL BE 2" (MIN.) LARGER THAN O.D. OF PIPE DIA. = 6 db (FOR #3 THRU #8) DIA. = 8 db (FOR #9, #10 & #11) DIA. = 10 db (FOR #14 & #18) (db = BAR DIAMETER) NOTE: BEND 4 db MINIMUM FOR STIRRUPS & TIES. 6" db BUT NOT LESS THAN 2 1 2" MIN. 12 d b db DIA . DIA . DIA . DIA . NOTE: FOR SIZE & SPACING OF ALL TIES AND STIRRUPS, REFER TO SCHEDULE AND/OR TYPICAL DETAILS. ALTERNATE POSITION OF 135° AND 90° BENDS TYPICAL ALTERNATE POSITION OF SUCCESSIVE TIE SPLICES TYPICAL. DIMENSION "a" FOR #3 TIES = 5" FOR #4 TIES = 5 1 2 " FOR #5 TIES = 6" TYPICAL COLUMN TIES BEAM STIRRUPS "a"12" DIA."a""a""a" "a " "a"OPTIONALDUCTILE A B C D E INSTALL 2x FILLER PIECES AS SHOWN TO BRIDGE BOLT HEAD STUDS @ 16" O.C. TYP. U.O.N. 16d TYP AS SHOWN STILL PLATE NOTE: THIS DETAIL REQUIRED WHEN EITHER "A" OR "B" IS GREATER THAN 9". ELEVATION 6-16d EACH SIDE OF SPLICE 2x SILL SPLICE TYP. SILL BOLTS "A""B" SPLICE LINE COUNTERSINK WITH CARE OVER BOLT STUDS @ 16" O.C. TYP. U.O.N. PARTITION TOP CONNECTION JOIST/TRUSS PER PLAN 1/ 2 " C L E A R 2x4 BLOCK @ 48" O.C. SIMPSON STC @ 48" O.C. PARTITION WALL PER PLAN PARALLEL TO JOIST/TRUSS 1/ 2 " C L E A R JOIST/TRUSS PER PLAN SIMPSON STC @ 48" O.C. PARTITION WALL PER PLAN PERP. TO JOIST/TRUSS JOIST/TRUSS PER PLAN SIMPSON HTC @ 48" O.C. PARTITION WALL PER PLAN 1/ 2 " C L E A R 8 1 6 N T O W N E R S T . GA R A G E T O A D U 81 6 N T O W N E R S T . SA N T A A N A , C A 9 2 7 0 3 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @rsi.plans www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.24-347 DATE:8/1/24 RAMIREZ STRUCTURAL INC TYPICAL DETAILS S3.0 816 N Towner St #2 9/23/2024 PLATE BOLTING BOLT SIZE PLATE WASHER SIZE 1 2" PL.229x3x3 5 8 " PL .229x3x3 3 4 " PL .229x3x3 7 8 " PL 5 16 "x3x3 1" PL 3 8 "x3 1 2"x2 1 2 " MIN. 2 BOLTS IN EA. SILL SECTION 5 8 " DIA. A.B. @ 48" TYPICAL, SEE SHEARWALL SCHEDULE FOR OTHER SPACING AT SHEARWALLS WHERE SILL PLATE IS DRILLED OR NOTCHED MORE THAN 1/3 OF THE PLATE WIDTH, INSTALL ONE BOLT EACH SIDE OF NOTCH WASHER PLATE PER SCHEDULE ABOVE 9" 9" 9"9"9"9"9" EQ.EQ. ST A G G . E D G E N A I L I N G @ A L L P A N E L E D G E S FI E L D N A I L I N G @ A L L O T H E R S T U D S OF F S E T SPECIAL INSPECTION SIMPSON'S 'SET-XP' (ICC# ESR-2508 LARR 25744) 5" MIN. EMBED DRILL & EPOXY w/ REQUIRED 13 57 911 TOP PLATE SPLICE8 1112 HOLDOWN AND SSTB ANCHOR SHEARWALL ASSEMBLY w/ SHEATHING ON BOTH SIDES SHEARWALL ASSEMBLY w/ SHEATHING ON ONE SIDE ROOF/FLOOR DIAPHRAGM ASSEMBLY BORING AND NOTCHING3x SILL REQ'D. AT (E) 2x SILL DEPTH "D" .25x"D" MAX. AT BEARING WALL .40x"D" MAX. AT NON-BEARING WALL .40x"D" MAX. AT BEARING WALL .60x"D" MAX. AT NON-BEARING WALL 5 8" MIN TYPL "D"/3 MAX. BORED HOLES 2" M I N . T Y P . 12" MIN SEP. DE P T H " D " "D " / 6 M A X . NO T C H "D " / 4 M A X A T E N D S B - STUDS IN WALLSA - JOIST/RAFTERS NOTCHING NOT ALLOWED IN MIDDLE 1 3 OF SPAN MARK MIN. PL. THK. NAILS DESIGN LOAD 6 2x 6-16d 1250# 8 2x 8-16d 1670# 10 2x 10-16d 2090# 12 2x 12-16d 2510# 14 2x 14-16d 2920# 16 2x 16-16d 3340# 18 2x 18-16d 3760# 20 2x 20-16d (1)3780#/4180# * = 6'-0" MIN. LAP LENGTH AT SPLCE 20, 22 & 24 GROUP NAILS OR BOLTS ON BOTH SIDES OF SPLICE IN TOP PLATE NAILS PER SCH 4'-0" MIN LAP * 1 1 2" MIN.1 1 2" MIN.1 1 2" MIN.1 1 2" MIN. NAILS PER SCH 16d @ 16" TYP 16d @ 16" TYP @ 3" MIN. TYP 1" 1" STAGGER NAILS TYP NOTES: 1. STUD AND BLOCKING SIZES: SHEARWALL TYPE I = 2x SHEARWALL TYPE II = 3x MIN AT PANEL EDGES 2x AT OTHER SUDS 2. SEE HOLDOWN DETAIL FOR ADDITIONAL HOLDOWN POST SIZE REQUIREMENTS 3. SILL AT FOUNDATION: SHEARWALL TYPE I = 2x SHEARWALL TYPE II = 3x (SEE "TYPICAL SILL PLATE BOLTING" DETAIL FOR WASHER PLATES AT ANCHOR BOLTS) STUD HD POST EA END (SEE NOTE 2) EDGE NAILING TO HD POST (FULL HEIGHT) STUDS @ 16" (MAX) (SEE NOTE 1) EDGE NAILING TO TOP PLATES STAGGERED (SHEARWALL TYPES I & II) SHEATHING @ OPENINGS FOR FLUSH FINISH DOOR OR WINDOW HEADER EDGE NAILING TO HD POST (FULL HEIGHT) BLOCKING @ ALL PANELS EDGES (SEE NOTE 1) TRIMMER STUD(S) HOLDOWN PER PLAN (SEE HOLDOWN DETAIL) EDGING NAILING TO SILL SILL BOLTING OR NAILING TOP PLATES STAGGERED NAILING PANEL JOINT SP A C I N G PE R S C H E D U L E 3 8" MIN. NOTE: THIS DETAIL TO BE USED ONLY WHERE 3x SILL IS REQUIRED AS INDICATED ON SHEARWALL DETAILS AND SCHEDULE. EXISTING STUD WALL ANCHOR BOLTS SIZE & SPACING PER SHEARWALL SCHEDULE 2x BLOCKING w/4-16d NAILS/BLK. EXISTING 2x SILL PLATE w/ ANCHOR BOLTS 2x(STUD DEPTH) AT PANEL JOINT 2x(STUD DEPTH) AT PANERL JOINT w/16d AT 2" STAGGERED (USE ONLY WHERE 3x REQUIRED) PANEL JOINT SHEATHING PER PLAN (WHERE OCCURS)PLAN NOTES: 1. SHEATHING ON ONE SIDE OF THE SHEARWALL MUST BE NAILED COMPLETELY BEFORE THE FRAME INSPECTION. SHEATHING ON THE OTHER SIDE MUST BE INSTALLED AND INSPECTED PRIOR TO INSTALLATION OF WALL SURFACE COVERING 2. SEE HOLDOWN DETAIL FOR ADDITIONAL HOLDOWN POST SIZE REQUIREMENTS. FRAMING TABLE TYPE III TYPE IV MINIMUM DBL. TOP PL. 2-2x 2-3x6 MIN. PANEL EDGE STUD 3x 4x6 OTHER STUDS MINIMUM 2x 2x6 MIN. BLKG. 3x 4x6 MIN. SILL 3x 3x6 MIN. HD POST 4x 4x6 (SHEARWALL TYPES III & IV) STUD HD POST EA END (SEE NOTE 2) EDGE NAILING TO HD POST (FULL HEIGHT) STUDS @ 16" (MAX) STAGGERED EDGE NAILING @ ALL PANEL EDGES TOP PLATES SHEATHING @ OPENINGS FOR FLUSH FINISH DOOR OR WINDOW HEADER EDGE NAILING TO HD POST (FULL HEIGHT) BLOCKING @ ALL PANELS EDGES TRIMMER STUD(S) HOLDOWN PER PLAN (SEE HOLDOWN DETAIL) EDGING NAILING TO SILL SILL BOLTING OR NAILING FIELD NAILING @ ALL OTHER STUDS EDGE NAILING TO TOP PLATES STAGGERED STAGGERED PANEL JOINT EACH SIDE OF WALL (VERT. & HORIZ) 16 " M I N . OF F S E T MARK MIN. HD POST (WALL 2x4 & 2x6) NO. OF SDS 1 4"x3 SCRES CL SIMPSON STRONGTIE ANCHOR BOLT ANCHOR DIA. MIN. ANCHOR EMBED Le MIN FOOTING WIDTH ALLOW TENSION KIPS MINDWALL CORNER HDU2 4x4 & 4x6 6 1 5/16"SSTB16 5/8"12 5/8"12"3.780 2.550 HDU4 4x4 & 4x6 10 1 5/16"SSTB20 5/8"16 5/8"12"4.785 2.960 HDU5 4x4 & 4x6 14 1 5/16"SSTB24 5/8"20 5/8"12"5.790 3.325 HDU8 4x6 & 4x6 20 1 3/8"SSTB28 7/8"24 7/8"12"11.060 7.315 HDU11 4x6 & 4x6 30 1 3/8"SSTB34 7/8"28 7/8"12"11.060 7.315 HDU14 4x8 & 6x6 36 1 9/16"SB1x30 1"24"12"16.300 13.090 1) ALL HOLDOWN ANCHOR BOLTS SHALL BE SECURELY FASTENED IN PLACE PRIOR TO PLACING CONCRETE. SSTB FOOTING SLAB EMBEDMEMT LINE l e 30 " M I N . RE B A R L E N G T H 5" MIN. 1 3/4" MIN. DIAGONAL PLACE IN CORNER APPLICATION 12" MIN. FOR 7/8" DIA. SSTB TABLE LOAD FOR FULL MI N . R E B A R L E N G T H 2x 1 e + 1 2 " 2x 1 e + 1 2 " MI N . R E B A R L E N G T H LOCATE APPROX. 45° FROM WALL MIN. 5" 1 3/4" MIN. Le AS R E Q ' D . TRIMMERS AT OPENINGS PER TYP. DETAIL SILL PLATE ANCHOR BOLT PER SCHEDULE BELOW HD POST PER PLAN HOLDOWN PER PLAN EMBED LINE Le 1" C L R . EMBED LINE CL PAD GRADE BOLT DIA. "D" 1/2" 5/8" 3/4" 7/8" 1" 1 1/8" 5" 5" 5" 6" 7" 8" 7" 7" 7" 8" 9" 10" MINIMUM EMBEDMENT D ST D . H E X N U T STD. HEX HEAD IN T O C O N C . O R M A S . EM B E D M E N T L E N G T H 4 D ST D . H E X N U T 3DD "J" BOLTSA ALL MATERIALS ATTACHMENT OF EXTENSION FOR ADEQUATE THRD. IN T O C O N C . O R M A S . EM B E D M E N T L E N G T H ALL MATERIALS ATTACHMENT OF EXTENSION FOR ADEQUATE THRD. VERT. ANCHOR BOLTS HORIZ. ANCHOR BOLTS HEADED BOLTSB ON PLANS/DETAILS USE "J" BOLTS U.O.N. NOTE: TYP. ANCHOR BOLTS SEE PLAN FOR SHEATHING THICKNESS, GRADE AND NAILING 1'-4" MIN. PANEL JOINT STAGGERED 4'-0" MIN, PANEL EDGE NAILING (E.N.) AT DIAPHRAGM EDGES FIELD NAILING (F.N.) AT INTERMEDIATE SUPPORTS 4'-0" SHEATHING PANELS BEAM PER PLAN EDGE NAILING (E.N.) AT CONTINUOUS PANEL EDGES WHERE BLOCKING OF PANEL EDGES IS REQUIRED EDGE NAILING (E.N.) AT STAGGERED PANEL EDGES JOISTS OR RAFTERS PER PLAN SEE PLAN FOR DIAPHRAGM AREAS WITH BLOCKED PANEL EDGES 3 8 1 6 N T O W N E R S T . GA R A G E T O A D U 81 6 N T O W N E R S T . SA N T A A N A , C A 9 2 7 0 3 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @rsi.plans www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.24-347 DATE:8/1/24 RAMIREZ STRUCTURAL INC TYPICAL DETAILS S3.1 816 N Towner St #2 9/23/2024 13 5678 910 HEADER DETAIL HEADER SCHEDULE BEARING AND EXTERIOR WALLS NON-BEARING WALLS OPENING WIDTH HEADER SIZE OPENING WIDTH HEADER SIZE 6'-0" OR LESS 4x6 8'-0" OR LESS 4x6 6'-1" TO 8'-0" 4x8 8'-1" TO 12'-0" 4x8 8'-1" TO 10'-0" 4x10 NOTE: USE 6x LINTEL MEMBERS IN 2x6 STUD WALLS. 'A34' AT TOP & BOTTOM FOR FULL HEIGHT STUDS IN EXTERIOR WALLS CONT. DBL. TOP PLATES, PER PLAN STUDS & CRIPPLES @ 16" O.C. 'A34' FOR 3'-6" TO 8'-0" OPENINGS HDR. PER PLAN (IF NON ON PLAN USE HEADER PER SCHEDL. ABOVE) 2-16d FOR EACH 3" IN HEADER DEPTH TWO CRIPPLE STUDS WHEN HEADER IS LARGER THAN 4x8, OTHERWISE ONE 16d @ 8" O.C. EACH FULL HEIGHT STUD @ EXTERIOR WALLS ONLY SEE TABLE FOR NUMBER OF FULL HEIGHT STUDS TYPICAL 'A34' TOP AND BOTTOM AT SILL WHERE OCCURING 2x STUD WIDTH SILL WHERE OCCURING 16d @ 8" O.C. EACH FULL HEIGHT STUD @ EXTERIOR WALLS ONLYOPENING OPENING NUMBER OF FULL HEIGHT STUDS WIDTH ALL INTERIOR INTERIOR EXTERIOR WALLS BRG. WALLS NON-BEARING WALLS 7'-0" OR LESS 2 2 1 7'-1" TO 10'-0" 3 2 1 OVER 10'-0" 4 2 1 NOTE: OMIT FULL HEIGHT STUDS WHERE POST FOR HOLDOWN ANCHOR OCCURS. SEE PLAN AND TYPICAL HOLDOWN DETAIL. EXISTING OPENING EXISTING FRAMING (SHOWN SHADED) 2x WALL WIDTH STUDS @16" O.C. MAX. 16d FACE NAILS AT 16" O.C. MAX. 2-16 TOE NAILS, TYP. EXISTING OPENING TYP. EXIST. DOOR OR WINDOW OPENING CLOSURE EXISTING FRAMING (SHOWN SHADED) 2x WALL WIDTH STUDS @16" O.C. MAX. 16d FACE NAILS AT 16" O.C. MAX. 2x WALL WIDTH PLATE w/ SDS 1 4x4 AT 16" O.C. (5 8 " DIA. EXPANSION BOLTS @32" O.C. MAX TWO BOLTS MIN., TYP AT CONC. FLOOR) 2-16 TOE NAILS, TYP. 8" TYP. NEW DOOR OR WINDOW IN EXISTING WALL 2x TRIMMER STUD w/ 16d @12" A34 T&B EACH END (N) WINDOW OPNG. PER ARCH 2-2x SILL PLATE A34 T&B EACH END EXISTING FRAMING (SHOWN SHADED) A34 T&B EACH END HEADER PER PLANHEADER PER PLAN 2x TRIMMER STUD w/ 16d @12" (N) DOOR OPNG PER ARCH EXISTING FRAMING (SHOWN SHADED) 5 8 " THRD. ROD A.B. DRILL & EPOXY w/ SIMPSON'S 'SET-3G' (ICC #ESR-2508) 6" MIN. EMBED SPECIAL INSPECTION REQUIRED A34 TYP. BEAM PER PLAN 'ACE' POST CAP EACH SIDE POST PER PLAN 2x6 KNEE BRACE EACH SIDE w/ 2-5/8 DIA M.B.'S EACH END 2' - 0 " 8 1 6 N T O W N E R S T . GA R A G E T O A D U 81 6 N T O W N E R S T . SA N T A A N A , C A 9 2 7 0 3 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @rsi.plans www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.24-347 DATE:8/1/24 RAMIREZ STRUCTURAL INC TYPICAL DETAILS S3.2 816 N Towner St #2 9/23/2024 13 5678 9101112 STUD WALL PER PLAN 2x P.T.D.F. SILL PL w/ 5 8 " DIA. A.B. @ 32" DRILL & EPOXY w/ SIMPSON'S SET-3G (ESR-4057) 6" MIN. EMBED SPECIAL INSPECTION REQUIRED (E) SLAB (E) CONT FTG. 6" HIGH CONC. CURB #4 CONT. E.N. SHEATING PER PLAN AT (E) FTG.B (E) SLAB PAD GRADE P.T.D.F. SILL PL & A.B. PER SHEARWALL SCHEDULE (MIN: 2x w/ 5 8 "0 A.B. @ 48") STUD WALL PER PLAN MIN. CURB EM B E D #3 x @ 18" 24" PE R P L A N (B R G . D E P T H ) PE R P L A N ( 2 4 " M I N . ) (B R G . D E P T H ) 3" C L R . A. B . EM B D . REINF. PER PLAN 8" MI N . E.N. FINISH GRADE 6" # 3 CONT. SHEATING PER PLAN DRILL & EPOXY w/ SIMPSON'S 'SET-3G' (ICC #ESR-4057) 6" MIN. EMBED SPECIAL INSPECTION REQUIRED PER PLAN (12" MIN) 6" AT NEW FTG.A (E) SLAB (E) CONT FTG. AT (E) FTG.B (E) SLAB PAD GRADE EM B E D PE R P L A N (B R G . D E P T H ) PE R P L A N ( 2 4 " M I N . ) (B R G . D E P T H ) 3" C L R . REINF. PER PLAN 8" MI N . E.N. FINISH GRADE 6" PER PLAN (12" MIN) 6" AT NEW FTG.A HOLDOWN POST PER PLAN HOLDOWN PER PLAN THREADED ROD(SIZE PER HOLDOWN) DRILL & EPOXY SIMPSONS SET-3G (ESR-4057) 10" EMBED. FOR 5/8" DIA. A.B.S. 15" EMBED. FOR 7/8" DIA. A.B.S. SPECIAL INSP. REQ'D. HOLDOWN POST PER PLAN HOLDOWN PER PLAN FOR ITEMS NOT NOTED SEE 1 S4.0 EM B E D EM B E D (E) 2x SILL PLATE w/ 5 8 " DIA. SIMPSON RETROFIT BOLTS (RFB # 5x8) w/ SIMPSON SET-3G EPOXY(ESR-4057) SPACING PER SHEARWALL SCHEDULE) 6" EMBEDMENT (SPECIAL INSPECTION REQUIRED) SHEATING PER PLAN E.N. (E) SLAB (E) CONT FTG. HOLDOWN POST PER PLAN HOLDOWN PER PLAN (E) CONT FTG. THREADED ROD(SIZE PER HOLDOWN) DRILL & EPOXY SIMPSONS SET-3G (ESR-4057) 10" EMBED. FOR 5/8" DIA. A.B.S. 15" EMBED. FOR 7/8" DIA. A.B.S. SPECIAL INSP. REQ'D. FOR ITEMS NOT NOTED SEE 5 S4.0 (E) SLAB POST PER PLAN A34 CLIP EA. SIDE (A35 AT 6"" WALL) (E) SLAB FOR ITEMS NOT NOTED SEE 5 S4.0 8 1 6 N T O W N E R S T . GA R A G E T O A D U 81 6 N T O W N E R S T . SA N T A A N A , C A 9 2 7 0 3 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @rsi.plans www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.24-347 DATE:8/1/24 RAMIREZ STRUCTURAL INC FOUNDATION DETAILS S4.0 816 N Towner St #2 9/23/2024 1234 5678 9101112 6-10d LAP NAILS, TYP. CEILING JOIST PER PLAN (E) 2x CONT. SHAPED BLKG. w/ 'A35' @ 16" O.C. SHEATHING PER PLAN E.N. EXIST. FRAMING SHOWN SHADED CONT. DBL TOP PL'S 2x4 CRIPPLE STUDS @ 16" O.C. 2x4 CONT. SILL PL. EXIST. FRAMING SHOWN SHADED 2x BLKG. @ 24" O.C. CEILING JOIST PER PLAN 4x4 CONT. @ 48" O.C. MAX. (E) 2x CONT. SHAPED BLKG. w/A35 @ 16" O.C. TOP & BOTT. (FIELD VERIFY) CONT. DBL TOP PL'S 2x4 CRIPPLE STUDS @ 16" O.C. 2x4 CONT. SILL PL. SHEATHING PER PLAN 6-10d LAP NAILS, TYP. CEILING JOIST PER PLAN 2x CONT. SHAPED BLKG. w/ 'A35' @ 16" O.C. SHEATHING PER PLAN E.N. EXIST. FRAMING SHOWN SHADED CONT. DBL TOP PL'S 2x4 CRIPPLE STUDS @ 16" O.C. 2x4 CONT. SILL PL. STUDS PER PLAN CONT. DBL. TOP PLATE (SPLICE PER PLAN) E.N. EXIST. FRAMING SHOWN SHADED CEILING JOIST PER PLAN SHEATHING PER PLAN POST PER PLAN BEAM PER PLAN FOR ITEMS NOT NOTED SEE 2 S5.0 'ACE' POST CAP EACH SIDE 2x6 KNEE BRACE EACH SIDE w/ 2-5/8 DIA M.B.'S EACH END 7 S3.2 8 1 6 N T O W N E R S T . GA R A G E T O A D U 81 6 N T O W N E R S T . SA N T A A N A , C A 9 2 7 0 3 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @rsi.plans www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.24-347 DATE:8/1/24 RAMIREZ STRUCTURAL INC ROOF FRAMING DETAILS S5.0 816 N Towner St #2 9/23/2024 816 N Towner St #2 9/23/2024 816 N Towner St #2 9/23/2024 816 N Towner St #2 9/23/2024 C O P Y R I G H T N O T I C E : THESE DRAWINGS ARE THE PROPERTY OF HC DESIGNS & DRAFTING AND MAY NOT BE REPRODUCED OR MODIFIED IN ANY WAY WITHOUT CONSENT REVISIONS : DATE DESCRIPTION T-24(1) drawn by:date: scale: sheet: title: H.C. N0NE CLIENT : LOCATION : Energy Calcs 16542 BELLFLOWER BLVD #200 BELLFLOWER, CA 90706 OFFICE: 562. 514.2322 hcdesigns.drafting@yahoo.com BEATRIZ & RUTH PRECIADO 816 N. TOWNER ST SANTA ANA, CA 92703 816 N. TOWNER ST, UNIT #2 SANTA ANA, CA 92703 JAN. 2024 816 N Towner St #2 9/23/2024 C O P Y R I G H T N O T I C E : THESE DRAWINGS ARE THE PROPERTY OF HC DESIGNS & DRAFTING AND MAY NOT BE REPRODUCED OR MODIFIED IN ANY WAY WITHOUT CONSENT REVISIONS : DATE DESCRIPTION T-24(2) drawn by:date: scale: sheet: title: H.C. N0NE Energy Calcs CLIENT : LOCATION : 16542 BELLFLOWER BLVD #200 BELLFLOWER, CA 90706 OFFICE: 562. 514.2322 hcdesigns.drafting@yahoo.com BEATRIZ & RUTH PRECIADO 816 N. TOWNER ST SANTA ANA, CA 92703 816 N. TOWNER ST, UNIT #2 SANTA ANA, CA 92703 JAN. 2024 816 N Towner St #2 9/23/2024 C O P Y R I G H T N O T I C E : THESE DRAWINGS ARE THE PROPERTY OF HC DESIGNS & DRAFTING AND MAY NOT BE REPRODUCED OR MODIFIED IN ANY WAY WITHOUT CONSENT REVISIONS : DATE DESCRIPTION T-24(3) drawn by:date: scale: sheet: title: H.C. N0NE Energy Calcs CLIENT : LOCATION : 16542 BELLFLOWER BLVD #200 BELLFLOWER, CA 90706 OFFICE: 562. 514.2322 hcdesigns.drafting@yahoo.com BEATRIZ & RUTH PRECIADO 816 N. TOWNER ST SANTA ANA, CA 92703 816 N. TOWNER ST, UNIT #2 SANTA ANA, CA 92703 JAN. 2024 816 N Towner St #2 9/23/2024 jose@ramirezstructural.com (562) 519-6045 ENGINEERED BY: JOSE RAMIREZ, PE CONTACT: STRUCTURAL CALCULATIONS FOR 816 TOWNER ST. GARAGE TO ADU 816 TOWNER ST. SANTA ANA, CA 92703 816 N Towner St #2 9/23/2024 DESIGN CRITERIA 1. SOIL BEARING PRESSURE: 1500 PSF 2. FOOTING MINIMUM BEARING DEPTH: 18 IN 3. CONCRETE MIN. COMPRESSIVE STRENGTH: 2500 PSI 4. REINFORCING SHALL CON FORM TO: ASTM 615, GRADE 60 5. ALL LUMBER SHALL BE GRADE MARKED DOUGLAS FIR. a. LIGHT FRAMING (CONSTRUCTION) b. JOIST &PLANKS (No .2) c. BEAMS & STRINGERS (No.1) d. POSTS & TIMBERS (No.1) 6. PLYWOOD SHALL CONFORM TO: PS 1-95, STRUCTURAL 1 7. ALL MATERIALS & WORKMANSHIP TO CONFORM TO 2022 CALIFORNIA BUILDING CODE. jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 DESIGN LOADS EXTERIOR WALLS 7/8" stucco 10 psf 1/2" plywood 1.5 psf 2x6 studs at 16" o.c.1.5 psf 1/2" gyp board 2.5 psf MEP + MISC.0.5 psf D = 16 psf PARTITION WALLS Drywall (2-sides)5.0 psf 2x4 studs 1.5 psf MEP + MISC.1.5 psf D = 8 psf ROOF LOADS Composite shingles 3.0 psf Re-roofing 2.0 psf 1/2" plywood 1.5 psf Rafters 3.0 psf Beams/Headers 1.0 psf MEP + MISC.1.0 psf Insulation 0.5 psf Ceiling 3.0 psf Solar panel.N/A D = 15 psf Lr = 20 psf REDUCIBLE jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 ROOF KEYPLAN 2x 1 0 C . J . @ 1 6 " O . C . 4x 6 4x6 4x6 4x6 4x 6 BM. BM. 2x6 RAFTERS @ 24" O.C. H1 H2 H3 H4 H4 CJ 1 RJ1 B1 B1 jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 Fb= 900 psi Fv= 180 psi L/ 180 (TL) L/ 240 (LL)E psi Tag: L= Uniform Loads Member:2x 10 Cd=1.25 Cr=1.15 Cf=1.10 Vd=k < VA=k OK M=k-ft < MA=k-ft OK DTL=in = L/OK USE:2x 10 JOIST @ 16" O.C. DLL=in = L/OK515 46.67 1.5 9.25 b (in) d (in) 20 15 16 1600000 CEILING JOIST CJ1 20.17 ft D (psf) L (psf) S (in) w (plf) 0.43 2.37 2.54 2.08 1.10 0.47 221 jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 ENGR. JR DATE: NOTCH ON COMPRESSION FACE AT END V 430 lbs member type= b=1.5 in viga Fv=psi d 9.25 in viga Cd= dn= 5.00 in F'v=psi e=10.38 in 'e' > 'dn', therefore use Eq.(3.4-2) d-dn= 4.25 2018 NDS Equation 3.4-5 fv= 2b = 3 x =psi < psi, therefore NA 2 x 1.5 x 9.25 - x 10 Use Eq. (3.4-2) 2018 NDS Equation 3.4-2 fv=1.5V psi < psi, therefore Satisfactory (.38) b dn 8/1/2024 CJ1 2x 180 1.25 225 3V d-(d-dn)/(dn)*e 430 41 225 4.25 5.00 =86 225 816 N Towner St #2 9/23/2024 ROOF JOIST Tag:RJ-1 L=2.17 ft Uniform Loads D (psf) L (psf) s (in) W (plf) Shear:Vmax <Vallow OK 0.08 K 0.79 K Flexure:Mmax <Mallow OK 0.04 k-ft 0.37 k-ft USE:24" O.C. Deflection:Δ =0.00 in = L/6423 OK INSTEAD, USE: 4x6 2x4 RAFTERS @ jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 HEADERS Tag:H1 L = 2.00 ft Uniform Loads D (psf) L (psf) Trib. (ft) W 23%Shear:Vmax <Vallow Roof 15 20 11.50 403 OK 0.43 K 1.84 K Floor Wall 16 1.50 24 29%Flexure:Mmax <allow Σw =0.427 klf OK 0.21 k-ft 0.74 k-ft 8%Deflection:Δ =0.01 in = L/3128 USE:OK INSTEAD, USE: 4x6 Tag:H2 L = 4.00 ft Uniform Loads D (psf) L (psf) Trib. (ft) W 18%Shear:Vmax <Vallow Roof 15 20 4.17 146 OK 0.34 K 1.84 K Floor Wall 16 1.50 24 46%Flexure:Mmax <allow Σw =0.170 klf OK 0.34 k-ft 0.74 k-ft 24%Deflection:Δ =0.05 in = L/982 USE:OK INSTEAD, USE: 4x6 Tag:H3 L = 3.00 ft Uniform Loads D (psf) L (psf) Trib. (ft) W 14%Shear:Vmax <Vallow Roof 15 20 4.17 146 OK 0.25 K 1.84 K Floor Wall 16 1.50 24 26%Flexure:Mmax <allow Σw =0.170 klf OK 0.19 k-ft 0.74 k-ft 10%Deflection:Δ =0.02 in = L/2327 USE:OK INSTEAD, USE: 4x6 4x4 4x4 4x4 𝑉=2 𝑀=𝑊𝐿 8 𝑉=2 𝑀=𝑊𝐿 8 𝑉=2 𝑀=𝑊𝐿 8 jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 HEADERS Tag:H4 L = 4.00 ft Uniform Loads D (psf) L (psf) Trib. (ft) W 30%Shear:Vmax <Vallow Roof 15 20 11.50 403 OK 0.85 K 2.89 K Floor Wall 16 1.50 24 40%Flexure:Mmax <allow Σw =0.427 klf OK 0.85 k-ft 2.15 k-ft 16%Deflection:Δ =0.03 in = L/1517 USE:OK4x6 𝑉=2 𝑀=𝑊𝐿 8 jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 FOUNDATION KEYPLAN CF1 CF2 jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 Continuous Footings CF-1 D (psf)L (psf)Trib. (ft)Total (plf) Roof 15 20 11.50 402.50 Floor Wall 16 8.00 128.00 530.50 plf 531 plf 0.35 ft 1500 psf USE: CF-2 D (psf)L (psf)Trib. (ft)Total (plf) Roof 15 20 4.16 145.60 Floor Wall 16 8.00 128.00 273.60 plf 274 plf 0.18 ft 1500 psf USE: = B === 1'-0" WIDE FTG. 1'-0" WIDE FTG. B == jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 INPUT DATA Exposure category (B, C or D)B Importance factor I =1.00 Category II Basic wind speed V =110 mph Topographic factor Kzt =1 Flat Building height to eave he =8.00 ft Building height to ridge hr =11.75 ft Effective area of components A =441.00 2 DESIGN SUMMARY Max horizontal force normal to building length, L, face =2.96 kips X 0.6=1.77 kips (ASD) Max horizontal force normal to building length, B, face =2.89 kips X 0.6=1.73 kips (ASD) Max total horizontal torsional load =8 ft-kips Max total upward force =6.23 kips ANALYSIS Velocity pressure qh = 0.00256 Kh Kzt Kd V2 I =18.43 psf where: qh = velocity pressure at mean roof height, h. Kh = velocity pressure exposure coefficient evaluated at height, h,= 0.70 Kd = wind directionality factor =0.85 h = mean roof height =9.88 ft < 60 ft, [Satisfactory] Design pressures for MWFRS p = qh [(G Cpf )-(G Cpi )] where:p = pressure in appropriate zone G Cp f = product of gust effect factor and external pressure coefficient G Cp i = product of gust effect factor and internal pressure coefficient =0.18 or -0.18 a = width of edge strips, MAX[ MIN(0.1B, 0.4h), 0.04B,3] =3.00 ft Net Pressures (psf), Basic Load Cases Net Pressures (psf), Torsional Load Cases 20.40 0.00 20.40 (+GCp i )(-GCp i )(+GCp i )(-GCp i )(+GCp i )(-GCp i ) 1 0.53 6.47 13.11 0.40 4.05 10.69 1T 0.53 1.62 3.28 2 -0.65 -15.37 -8.74 -0.69 -16.03 -9.40 2T -0.65 -3.84 -2.18 3 -0.48 -12.13 -5.49 -0.37 -10.14 -3.50 3T -0.48 -3.03 -1.37 4 -0.43 -11.20 -4.56 -0.29 -8.66 -2.03 4T -0.43 -2.80 -1.14 1E 0.80 11.35 17.98 0.61 7.93 14.56 0.00 2E -1.02 -22.05 -15.41 -1.07 -23.04 -16.40 3E -0.68 -15.92 -9.28 -0.53 -13.09 -6.45 (+GCp i )(-GCp i ) 4E -0.63 -15.00 -8.36 -0.43 -11.24 -4.61 1T 0.40 1.01 2.67 5 -0.45 -11.61 -4.98 -0.45 -11.61 -4.98 2T -0.69 -4.01 -2.35 6 -0.45 -11.61 -4.98 -0.45 -11.61 -4.98 3T -0.37 -2.53 -0.88 4T -0.29 -2.17 -0.51 Net Pressure withSurface Roof angle q = G Cp f Wind Analysis for Low-rise Building, Based on ASCE 7-16 / IBC 2021 / CBC 2022 Roof angle q = G Cp f Net Pressure with Surface Roof angle q = G Cp f Net Pressure withSurface Roof angle q = Net Pressure withG Cp f jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 Basic Load Cases in Transverse Direction Basic Load Cases in Longitudinal Direction Area Area 2)(+GCp i )(-GCp i )2)(+GCp i )(-GCp i ) 1 113 0.73 1.49 1 144 0.59 1.54 2 152 -2.34 -1.33 2 152 -2.44 -1.43 3 152 -1.85 -0.84 3 152 -1.54 -0.53 4 113 -1.27 -0.52 4 144 -1.25 -0.29 1E 48 0.54 0.86 1E 55 0.43 0.80 2E 65 -1.42 -1.00 2E 65 -1.49 -1.06 3E 65 -1.03 -0.60 3E 65 -0.84 -0.42 4E 48 -0.72 -0.40 4E 55 -0.61 -0.25 Horiz.2.96 2.96 Horiz.2.89 2.89 Vert.-6.23 -3.53 Vert.-5.92 -3.23 10 psf min.Horiz.2.37 2.37 10 psf min.Horiz.1.99 1.99 Sec. 6.1.4.1 Vert.-4.07 -4.07 Sec. 6.1.4.1 Vert.-4.07 -4.07 Torsional Load Cases in Transverse Direction Torsional Load Cases in Longitudinal Direction Area Area 2)(+GCp i )(-GCp i )(+GCp i )(-GCp i )2)(+GCp i )(-GCp i )(+GCp i )(-GCp i ) 1 33 0.21 0.43 1 2 1 45 0.18 0.48 0 1 2 44 -0.68 -0.38 -1 0 2 88 -1.41 -0.83 2 1 3 44 -0.53 -0.24 1 0 3 88 -0.89 -0.31 -2 -1 4 33 -0.37 -0.15 1 1 4 45 -0.39 -0.09 1 0 1E 48 0.54 0.86 4 6 1E 55 0.43 0.80 3 6 2E 65 -1.42 -1.00 -4 -2 2E 65 -1.49 -1.06 3 2 3E 65 -1.03 -0.60 3 1 3E 65 -0.84 -0.42 -1 -1 4E 48 -0.72 -0.40 5 3 4E 55 -0.61 -0.25 4 2 1T 81 0.13 0.26 -1 -1 1T 100 0.10 0.27 0 -1 2T 108 -0.42 -0.24 1 0 2T 152 -0.61 -0.36 -2 -1 3T 108 -0.33 -0.15 -1 0 3T 152 -0.39 -0.13 1 0 4T 81 -0.23 -0.09 -1 0 4T 100 -0.22 -0.05 -1 0 8 8 8.2 8.2 Design pressures for components and cladding p = qh[ (G Cp) - (G Cpi)] where:p = pressure on component pmin = 10 psf (Sec. 6.1.4.2, pg 21) G Cp = external pressure coefficient. see table below Effective Area (ft2) GCP - GCP GCP - GCP GCP - GCP GCP - GCP GCP - GCP Comp.441 0.30 -0.80 0.30 -1.20 0.30 -2.00 0.71 -0.81 0.71 -0.82 Positive Negative Positive Negative Positive Negative Positive Negative Positive Negative 10.00 -18.06 10.00 -25.43 10.00 -40.18 16.40 -18.24 16.40 -18.42 S Surface Pressure (k) withPressure (k) with S Surface Zone 3 Zone 4 Zone 5 Pressure (k) withSurface Torsion (ft-k) Total Horiz. Torsional Load, MT Surface Pressure (k) with Torsion (ft-k) Zone 4 Zone 5 Pressure Zone 1 Zone 2 Total Horiz. Torsional Load, MT Comp. & Cladding Zone 1 ( psf ) Zone 3Zone 2 jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 ASCE Hazards Report Address: 816 N Towner St Santa Ana, California 92703 Standard:ASCE/SEI 7-22 Latitude:33.752247 Risk Category:II Longitude:-117.880592 Soil Class:Default Elevation:111.03340063640205 ft (NAVD 88) Page 1 of 4https://ascehazardtool.org/Fri Jun 07 2024 816 N Towner St #2 9/23/2024 PGA M : 0.67 SMS : 1.76 SM1 : 1.22 SDS : 1.17 SD1 : 0.81 T L : 8 SS : 1.49 S1 : 0.53 VS30 : 260 Seismic Design Category:D Multi-Period Design Spectrum S (g) vs T(s)a Multi-Period MCE SpectrumR S (g) vs T(s)a Two-Period Design Spectrum S (g) vs T(s)a Two-Period MCE SpectrumR S (g) vs T(s)a Design Vertical Response Spectrum Vertical ground motion data has not yet been made available by USGS. MCE Vertical Response SpectrumR Vertical ground motion data has not yet been made available by USGS. Seismic DefaultSite Soil Class: Results: Page 2 of 4https://ascehazardtool.org/Fri Jun 07 2024 816 N Towner St #2 9/23/2024 SEISMIC BASE SHEAR (ASCE7-22) D 1.3 6.5 1 1.760 0 1.220 1.173 0.813 0.095 0.094 W 1.315 W 0.181 0.235 W 0.164 W 𝑆= 𝑆= 𝑆=3 𝑆 = 𝑆=3 𝑆 = 𝑇= 𝐶ℎ = ℎ= 𝑥= = = =. = = = = = == = = = jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 SEISMIC ANALYSIS WEIGHT D PART. Level 1 W roof =15 psf +8 psf x 542.0 ft²=12.47 kips W TOTAL W wall =16 psf x 8 ft /2 x 84.00 ft =5.38 kips 17.84 kips WR =17.84 kips BASE SHEAR 0.164 x 17.84 kips = 2.93 kips / 542 ft² F1= DISTRIBUTION OF BASE SHEAR 1 Level 2 or more levels 5.407 psf 𝑽𝑩𝑨𝑺𝑬= 𝑽 ∗ 𝑾𝑻𝑶𝑻𝑨𝑳 = 𝑉 ∗ 𝑊= 𝑭𝒙= 𝑽𝑩𝑨𝑺𝑬∗𝑾𝑿∗ 𝒉𝑻𝑶𝑻𝑨𝑳 𝑾𝟏∗ 𝒉𝟏+𝑾𝟐∗𝒉𝟏+ 𝒉𝟐+ ⋯𝑾𝒏∗ 𝒉𝑻𝑶𝑻𝑨𝑳 𝑩𝑨𝑺𝑬=∗𝑻𝑶𝑻𝑨𝑳 𝑨 jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 X2.1 X1.1 Y1 . 1 Y2 . 1 14'-10" 8' - 2 " 6 6 6 8'-0" 21 ' - 0 " 6 SHEARWALLS KEYPLAN jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 SEISMIC FORCES First Floor Shearwall Forces F1= 6.710 psf SW U-FORCE T.A.L1 L2 L3 L4 X1 6.71 264.50 1.77 KIPS 14.83 ft X2 6.71 277.50 1.86 KIPS 8.00 ft Y1 6.71 277.50 1.86 KIPS 8.17 ft Y2 6.71 264.50 1.77 KIPS 21.00 ft LENGHT WALLS. SEE KEYPLANSLevel 1 jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 KEYPLAN TAG:X1.1 (14.83 ft), FORCE: SEISMIC GOVERNS =kips Load Comb. :(0.6-.14SDS) D + E SDS :1.170 SHEAR STRESS X1.1 :L1=ft v=lbs =plf ft Ltotal=ft OVERTURNING height= 8.00 ft OK USE: TYPE 6 SHEARWALL -0.44 x =kips kips OK 4x 4 POST w/H.D. SHEARWALL CALCULATIONS 301 0.00 14.83 HDU2 1.77 X1.1 14.83 120 14.83 1775 T= Tallow= 14.2 0.00 WALL: 0.301 16 1.77 15 Unit load 33.06 33.06 8.00 14.83 14.2 11.50 Tributary 173 128 14.83 14.83 jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 KEYPLAN TAG:X2.1 (8.00 ft), FORCE: SEISMIC GOVERNS =kips Load Comb. :(0.6-.14SDS) D + E SDS :1.170 SHEAR STRESS X2.1 :L1=ft v=lbs =plf ft Ltotal=ft OVERTURNING height= 8.00 ft OK USE: TYPE 6 SHEARWALL -0.44 x =kips kips OK 4x 4 POST w/H.D. SHEARWALL CALCULATIONS 301 1.34 8.00 HDU2 1.86 X2.1 8.00 233 8.00 1862 T= Tallow= 14.9 3.08 WALL: 0.301 16 1.86 15 Unit load 9.62 9.62 8.00 8.00 14.9 11.50 Tributary 173 128 8.00 8.00 jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 KEYPLAN TAG:Y1.1 (8.17 ft), FORCE: SEISMIC GOVERNS =kips Load Comb. :(0.6-.14SDS) D + E SDS :1.170 SHEAR STRESS Y1.1 :L1=ft v=lbs =plf ft Ltotal=ft OVERTURNING height= 8.00 ft OK USE: TYPE 6 SHEARWALL -0.44 x =kips kips OK 4x 4 POST w/H.D. SHEARWALL CALCULATIONS 190 1.48 8.17 HDU2 1.86 Y1.1 8.17 228 8.17 1862 T= Tallow= 14.9 3.08 WALL: 0.190 16 1.86 15 Unit load 6.35 6.35 8.00 8.17 14.9 4.16 Tributary 62 128 8.17 8.17 jose@ramirezstructural.com (562) 519-6045 816 N Towner St #2 9/23/2024 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area to Total Resulting Stories: Area Added in Past 2 Years Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed (PR400-402) Fire Sprinkler   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR 816 N Towner St #2 9/23/2024 816 N Towner St #2 9/23/2024 816 N Towner St #2 9/23/2024