Loading...
HomeMy WebLinkAbout613 W Bell Ave - PlanE1 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d ENPH DESIGN 01-02-2023 79275 5.60 PE T E M A B A S C A L SA N T A A N A C A 9 2 7 0 7 61 3 W B E L L A V E (7 1 4 ) 8 6 5 - 0 4 6 6 41 0 1 9 5 0 6 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 5. 6 0 k W D C P V ABBREVIATIONS AMPERE ALTERNATING CURRENT AUTHORITY HAVING JURISDICTION BUILDING CONCRETE COMBINER BOX CALIFORNIA ELECTRICAL CODE COPPER DISTRIBUTION PANEL DIRECT CURRENT EQUIPMENT GROUNDING CONDUCTOR (EXISTING) FIELD VERIFIED GALVANIZED GROUNDING ELECTRODE CONDUCTOR GROUND HOT DIPPED GALVANIZED CURRENT CURRENT AT MAX POWER INVERTER SHORT CIRCUIT CURRENT KILOVOLT AMPERE KILOWATT LOAD BEARING WALL MINIMUM MAIN CIRCUIT BREAKER MAIN SERVICE PANEL (NEW) NEMA 3R, RAINTIGHT OUTSIDE RATED NATIONAL ELECTRICAL CODE NOT TO SCALE ON CENTER OVERCURRENT PROTECTION DEVICE POLES -BREAKER POLES- PROPERTY LINES PHOTOVOLTAIC POLYVINYL CHLORIDE ROOF RAFTER SOLID BARE COPPER SOLAR PLANE SUBPANEL SCHEDULE STAINLESS STEEL PRACTICAL TESTING CONDITIONS SOLAR WATER HEATER TYPICAL UNLESS NOTED OTHERWISE VOLT VOLTAGE AT MAX POWER VOLTAGE AT OPEN CIRCUIT WATT A AC AHJ BLDG CONC CB CEC CU DP DC EGC (E) FV GALV GEC GND HDG I Imp INVT Isc kVA kW LBW MIN. MCB MSP (N) N3R NEC NTS OC OCPD P PL PV PVC RR SBC SP SPL SCH SS PTC SWH TYP UNO V Vmp Voc W SHEET INDEX E1 - COVER SHEET APPLICABLE CODES AND STANDARDS VICINITY MAP N SCOPE OF WORKGENERAL NOTES * OCCUPANCY TYPE: R-3 * CONSTRUCTION TYPE: TYPE V-B * UNSPRINKLERED DWELLING INFO E2 - SITE PLAN E7 - SINGLE LINE DIAGRAM E8 - ELECTRICAL NOTES E9 - SIGNAGE E5 - ROOF PLAN E6 - ATTACHMENT DETAIL ·(5.60) KW DC RATED PV ARRAY ·(1) 125A ENHAPSE IQ COMBINER 4C ·(14) HANWHA Q.PEAK DUO BLK ML-G10+ 400 SOLAR MODULES ·(14) IQ8M-72-2-US MICRO INVERTERS ·(1) 125A LOAD CENTER ·(1) 30A AC DISCONNECT E9.1 - SIGNAGE 1. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 2. EQUIPMENT. INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC PHOTOVOLTAIC MODULES, SOURCE-CIRCUIT COMBINERS, AND CHARGE CONTROLLERS INTENDED FOR USE IN PHOTOVOLTAIC POWER SYSTEMS SHALL BE IDENTIFIED AND LISTED FOR THE APPLICATION. [CEC 690.4(B)] 3. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND NON ROOF SWITCHES. ROOF SWITCHES TO BE NEMA 4 RATED. 4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. 5. PROTECTION DEVICES FOR PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS ALSO CONNECTED TO SOURCES HAVING SIGNIFICANTLY HIGHER CURRENT AVAILABILITY (E.G., PARALLEL STRINGS OF MODULES, UTILITY POWER), SHALL BE PROTECTED AT THE SOURCE FROM OVERCURRENT. [CEC 690.9(A)] 6. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS. [CEC 690.12] 7. THE UTILITY INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. [CEC 705.40] 8. ALL CONDUCTOR EXPOSED TO WEATHER SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT. [CEC 310.10(D)(1)] 9. THE MODULE CONDUCTORS MUST BE TYPE USE-2 OR LISTED FOR PHOTOVOLTAIC (PV) WIRE. [CEC 690.31(C)] 10. ALL CONDUCTORS SHALL BE MARKED ON EACH END FOR UNIQUE IDENTIFICATION. 11. AN INSULATED GROUNDED CONDUCTOR OF 6 AWG OR SMALLER SHALL BE IDENTIFIED AS A CONTINUOUS WHITE FINISH. [CEC 200.6] 12. THE OUTPUT OF AN INTERCONNECTED ELECTRICAL POWER SOURCE SHALL BE PERMITTED TO BE CONNECTED TO THE LOAD SIDE. INTERCONNECTING PROVISIONS FOR OTHER POWER SOURCES SHALL COMPLY WITH 705.12(B)(1) THROUGH 705.12(B)(3) 13. EACH SOURCE INTERCONNECTION OF ONE OR MORE POWER SOURCES INSTALLED IN ONE SYSTEM SHALL BE MADE AT A DEDICATED CIRCUIT BREAKER OR FUSIBLE DISCONNECTING MEANS. [CEC 705.12(A)] 14. THE SUM OF THE AMPERE RATING OF THE OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO THE BUSBAR OR CONDUCTOR SHALL NOT EXCEED 120% OF THE RATING OF BUSBAR OR CONDUCTOR. [CEC 705.12(B)(3)(2)] 15. A CONNECTION AT EITHER END, BUT NOT BOTH ENDS, OF A CENTER-FED PANEL BOARD IN DWELLINGS SHALL BE PERMITTED WHERE THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR DOES NOT EXCEED 120 PERCENT OF THE CURRENT RATING OF THE BUSBAR. [CEC 705.12(B)(3)(4)] 16. EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUS BAR OR CONDUCTOR SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. [CEC 705.12(C)] 17. CIRCUIT BREAKER, IF BACKFED, SHALL BE SUITABLE FOR SUCH OPERATION. [CEC 705.12(D)] 18. TO MINIMIZE OVERHEATING OF THE BUSBAR IN PANELBOARD, THE PANELBOARD MAIN CIRCUIT BREAKER AND THE PV POWER SOURCE CIRCUIT BREAKER SHALL BE PHYSICALLY LOCATED AT THE OPPOSITE END OF THE BUSBAR. 19. ALL THE CEC REQUIRED WARNING SIGNS, MARKINGS, AND LABELS SHALL BE POSTED ON EQUIPMENT AND DISCONNECTS PRIOR TO ANY INSPECTIONS TO BE PERFORMED BY THE BUILDING DEPARTMENT INSPECTOR. 20. WHERE PV SYSTEM DC CIRCUIT'S RUN INSIDE A BUILDING, THEY SHALL BE CONTAINED IN METAL RACEWAYS TYPE MC METAL CLAD CABLE OR METAL ENCLOSURES FROM POINT OF PENETRATION OF THE SURFACE OF THE BUILDING TO THE FIRST READILY ACCESSIBLE DISCONNECTING MEANS. [CEC 690.31(D)] 21. FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR THAT ARE IS IN ACCORDANCE WITH CEC 110.14. 22. CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30V DC OR 15V AC SHALL REQUIRE TOOL TO OPEN AND MARKED "DO NOT DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT INTERRUPTING". [CEC 690.33(C) & (D)] 23. EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR. [CEC 250.120(C)] 24. EQUIPMENT GROUNDING CONDUCTOR FOR PV SYSTEM CIRCUITS SHALL BE SIZED IN ACCORDANCE WITH 250.122. [CEC 690.45] 25. GROUNDING ELECTRODE CONDUCTOR(S) SHALL BE INSTALLED IN ONE CONTINUOUS LENGTH WITHOUT A SPLICE OR JOINT. IF NECESSARY, SPLICES OR CONNECTIONS SHALL BE MADE AS PERMITTED. [CEC 250.64(C)] 26. ALL SMOKE ALARMS, CARBON MONOXIDE ALARMS AND AUDIBLE NOTIFICATION DEVICES SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 217 AND UL 2034. THEY WILL BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND NFPA 720. [CRC 2022 R314 & R315] 27. SMOKE ALARMS AND CARBON MONOXIDE ALARMS WILL BE RETROFITTED INTO THE EXISTING DWELLING. THESE SMOKE ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. THESE ALARMS MAY BE SOLELY BATTERY OPERATED IF THE PHOTOVOLTAIC PROJECT DOES NOT INVOLVE THE REMOVAL OF INTERIOR WALL AND CEILING FINISHES INSIDE THE HOME, OTHERWISE, THE ALARMS MUST BE HARD WIRED AND INTERCONNECTED. ·2022 CBC ·2022 CRC ·2022 CEC ·2022 CMC ·2022 CPC ·2022 CFC ·2022 CEBC · 2022 BUILDING ENERGY EFFICIENCY STANDARDS ·AUTHORITY HAVING JURISDICTION ·CURRENT LOCAL FIRE CODE *ALL WORK TO COMPLY WITH ABOVE CODES BLDG # 101114299 ISS. 3/16/23 ELEC # 20179049 ISS. 3/1623 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 613 W Bell Ave 03/20/23 MAIN SERVICE PANEL GROUNDING ELECTRODE & AUXILLARY GROUNDING ELECTRODE AS NEEDED PER CEC 690.47 (6 FEET APART) L LL L GN D N A TOP FED ME T E R # 100A/2P 22 2 0 1 3 - 5 0 0 9 3 4 (E)100 (E) 70A/2P (N) GN D N (N) 125A LOAD CENTER NEMA-3R 3 (N) 30A/2P (N)70A/2P THWN-2 3-#4 1-#8 GRND 1" EMT CONDUIT AFCI PROTECTION WILL BE PROVIDED FOR 15A AND 20A BREAKERS THAT ARE RELOCATED MORE THAN 6' FROM THE ORIGINAL BREAKER SOURCE TRANSFER (E) MSP LOADS (N) 30A VISIBLY OPEN, LOCKABLE, AC DISCONNECT 240V NEMA-3R G 3 enphase ENERGY CELLULAR REVENUE-GRADE PRODUCTION METERING FACTORY INSTALLED MODEL #: X-IQ-AM1-240-4C CELLMODEM-M1-06 C E L L MODEM 20A/2P 20A/2P SPARE SPARE 15A Enphase IQ Gateway (N) 125A ENPHASE IQ COMBINER 4C NEMA-3R X-IQ-AM1-240-4C [CRD-PCS NEM] EACH WITH AN ENPHASE MICROINVERTER AC J-BOX G 1 STRING OF MODULES7 EACH WITH AN ENPHASE MICROINVERTER AC J-BOX G 1 STRING OF MODULES7 1 1 2 2 E7 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d ENPH DESIGN 01-02-2023 79275 5.60 PE T E M A B A S C A L SA N T A A N A C A 9 2 7 0 7 61 3 W B E L L A V E (7 1 4 ) 8 6 5 - 0 4 6 6 41 0 1 9 5 0 6 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 5. 6 0 k W D C P V UTILITY COMPANY: MSP VOLTAGE: MSP GROUND:SERV. TYPE: SERVICE INFO SCE 120/240 UNDERGROUND (E) UFER BUS BAR MAIN BREAKER MAX PV OUTPUT CURRENT 120% RULE FOR LC ( 125 x 1.2 ) - 70 = 80 QTY: INVERTER: WATTAGE:VOLTAGE:CEC EFF: INVERTER SPECS IQ8M-72-2-US 325240 97% 14 2% Avg. 1" MIN ASHRAE AMBIENT TEMPERATURE SPECS ° C ° C High Temp EXTREMEDISTANCE ABOVE ROOF NO TEMP ADDER PER 310.15(B)(3)(C) 31 2 WIRE QTY WIRE TAG #CONDUIT WIRE TYPE INVERTER QTY:NOC: CONDUIT FILL: TEMP RATING: WIRE AMP TEMP DE-RATE: A WIRE OCP: GRND SIZE GRND WIRE TYPEENPHASE TRUNK CABLE INCLUDES #12 GROUND WIRE GAUGE: x x = TERMINAL 75°C RATING: x x 1.25 NEC: = STRING AMPS A Ax x = x x 1.25 = A Ax x = x x 1.25 = A 1 AIR 2 #12 TRUNK CABLE 90°C 30 0.96 1 28.8 25A 7 1.35 11.81 #6 SBC 2 3/4" EMT 2 #10 THWN-2 90°C 40 0.96 1 38.4 35A 7 1.35 11.81 #8 THWN-2 3 3/4"EMT 3 #10 THWN-2 90°C 40 0.96 1 38.4 35A 14 1.35 23.63 #8 THWN-2 WIRE OCP FOR WIRES CONNECTED TO BREAKERS TO BE GREATER THAN THE SIZE OF THE BREAKER. EQUIPMENT TERMINALS ARE RATED AT 75°C. STRING AMPERAGE NOT TO EXCEED THE 75°C RATING OF THE WIRE THAT IS ATTACHED TO THE TERMINALS. NOTES NEW PV CONDUIT TO HIDDEN FROM VIEW. CONDUIT TO BE PAINTED TO MATCH THE EXISTING SURFACE. CONDUIT RUN TO BE DETERMINED BY INSTALLER. QTY:MODULE TYPE: WATTAGE: Isc:Imp: MODULE SPECS Voc:Vpmax: 14Q.PEAK ML-G10+ 400 400 45.3V 37.13V11.14A 10.77A WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. 70A SUB BREAKER =70 TOTAL AMPS 70A <100A MAIN AND BUS RATING INTERCONNECTION METHOD PER 705.12(B)(3)(2): WHERE TWO SOURCES, ONE A PRIMARY POWER SOURCE AND THE OTHER ANOTHER POWER SOURCE, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR. INTERCONNECTION METHOD PER 705.12(B)(3)(3): THE SUM OF THE AMPERE RATINGS OF ALL OVERCURRENT DEVICES ON PANELBOARDS, BOTH LOAD AND SUPPLY DEVICES, EXCLUDING THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR, SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED THE RATING OF THE BUSBAR. 613 W Bell Ave 03/20/23 ELECTRICAL NOTES: E8 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d ENPH DESIGN 01-02-2023 79275 5.60 PE T E M A B A S C A L SA N T A A N A C A 9 2 7 0 7 61 3 W B E L L A V E (7 1 4 ) 8 6 5 - 0 4 6 6 41 0 1 9 5 0 6 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 5. 6 0 k W D C P V CIRCUIT RELOCATION CALCULATION 1) ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER’S INSTALLATION INSTRUCTIONS. 2) ALL PV EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTED LAB. 3) NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. 4) WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ LINE AND LOAD. 5) WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKER SHALL BE INSTALLED AT THE OPPOSITE END OF THE BUS BAR OF THE MAIN BREAKER. 6) WORKING SPACE FOR EQUIPMENT OPERATING AT 1000 VOLTS, NOMINAL, OR LESS TO GROUND AND LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE WHILE ENERGIZED SHALL COMPLY WITH [CEC 110.26(A)] 7) ALL EXTERIOR CONDUITS, FITTINGS AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS PER [CEC 314.15]. 8) ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. 9) PV EQUIPMENT, SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL ONLY BE INSTALLED BY QUALIFIED PERSONS. [CEC 690.4 (C)]. 10) THE PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATED COLOR CODING, MARKING TAPE, TAGGING OR OTHER APPROVED MEANS. [CEC 690.31(B)(1)] 11) ADEQUATE SPACING MUST BE MAINTAINED BETWEEN ANY PLUMBING SEWER VENTS EXTENDING THROUGH THE ROOF AND THE UNDERSIDE OF THE PHOTOVOLTAIC PANELS (6" MINIMUM RECOMMENDED). 613 W Bell Ave 03/20/23 E9 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d ENPH DESIGN 01-02-2023 79275 5.60 PE T E M A B A S C A L SA N T A A N A C A 9 2 7 0 7 61 3 W B E L L A V E (7 1 4 ) 8 6 5 - 0 4 6 6 41 0 1 9 5 0 6 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 5. 6 0 k W D C P V MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DC PV CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. MARKING SHALL BE PLACED EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS, AND AT ALL PV COMBINER AND JUNCTION BOXES. [CEC 690.31(D)(2)] REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT) MARKING CONTENT AND FORMAT PER [ CEC 110.21(B)] WITH REFERENCE TO ANSI Z535.4-2011 -BACKGROUND PER ANSI Z535.4-2011 -LETTERING PER ANSI Z535.4-2011 -MINIMUM 3/8” LETTER HEIGHT -ALL CAPITAL LETTERS -ARIAL OR SIMILAR FONT, NON BOLD MARKING PV CIRCUIT 1 13 144 8 3 2 13 12 11 9 5 PV COMBINER (IF USED) FOR ILLUSTRATION ONLY (NOT ACTUAL MSP) MAIN SERVICE PANEL AC DISCONNECT (IF USED) PV METER (IF USED) LABEL LEGEND 9 1 1 2 3 4 4 5 8 9 13 13 14 5 3 5 15 15 18.9A 240V 613 W Bell Ave 03/20/23 ACCMSPLC ACD CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: PLACARD FOR THE MAIN SERVICE PANEL E9.1 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d ENPH DESIGN 01-02-2023 79275 5.60 PE T E M A B A S C A L SA N T A A N A C A 9 2 7 0 7 61 3 W B E L L A V E (7 1 4 ) 8 6 5 - 0 4 6 6 41 0 1 9 5 0 6 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 5. 6 0 k W D C P V SOLAR LOAD CENTER NO ADDITIONAL LOADS ALLOWED LABEL TO BE INSTALLED ON THE INSIDE AND THE OUTSIDE OF THE LOAD CENTER WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. N YOU ARE HERE SERVICE POINT & UTILITY METERING AC COMBINER SOLAR ARRAY AC DISCONNECT LOAD CENTER & PV DISCONNECT PHOTOVOLTAIC POWER SOURCE OPERATING AC VOLTAGE: BBBB B V MAXIMUM OPERATING AC OUTPUT CURRENT: BBBBB B AMPS LABEL FOR MAIN SERVICE PANEL COVER 240 18.9 QTY. 1 NOT ENERGIZED FULL RAPID SHUTDOWN PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: BBBB B A NOMINAL OPERATING AC VOLTAGE:BBBB B V 18.9 240 613 W Bell Ave 03/20/23 Expedited Permit Process for PV Systems - AC Module1 Expedited Permit Process for PV Systems AC Module The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the AC Module to use with the Expedited Permit Process. The Standard String, Micro-Inverter, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 613 W Bell Ave 03/20/23 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems AC Module The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 613 W Bell Ave 03/20/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 AC Module Site Plan                                                          Semper Solaris PETE M ABASCAL SOLAR 6197286511 613 W BELL AVESANTA ANA CA 92707 8.8 AC 613 W Bell Ave 03/20/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 AC Module Electrical Diagram Contractor Name, Address and Phone: One-Line Standard Electrical Diagram for AC Module PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A CONDUIT SIZE N/A N/A N/A DESCRIPTIONTAG 1 2 3 4 5 6 7 PART NUMBER NOTES FOR UNUSED AC MODULES PUT "N/A” in BLANK ABOVE 1 2 2 3 EQUIPMENT SCHEDULE J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 5 6 7 5 3 4 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ AC MODULES IN BRANCH- CIRCUIT MOD __1__ DC AC MOD __1__ DC AC MOD __1__ DC AC ____ AC MODULES IN BRANCH- CIRCUIT MOD __1__ DC AC MOD __1__ DC AC MOD __1__ DC AC 1 6197286511 Semper Solaris PETE M ABASCAL SOLAR 613 W BELL AVESANTA ANA CA 92707 8.8 AC 613 W Bell Ave 03/20/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for AC Module Electrical Diagram Contractor Name, Address and Phone: Bill Ted Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: NOMINAL OPERATING AC VOLTAGE NOMINAL OPERATING AC FREQUENCY MAXIMUM AC POWER MAXIMUM AC CURRENT MAXIMUM OCPD RATING AC MODULE MAKE AC MODULE MODEL AC MODULE RATINGS (Guide Appendix C) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT (N/A) 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH AC MODULE CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ___oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR 6 OR LESS CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR AC MODULES INVERTER OUTPUT CIRCUITS WITH 12 AMPS OR LESS WHEN PROTECTED BY A 15- AMP OR SMALLER OCPD. b) 10 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR AC MODULES INVERTER OUTPUT CIRCUITS WITH 16 AMPS OR LESS WHEN PROTECTED BY A 20- AMP OR SMALLER OCPD. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix F): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE®REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) N/A since no dc wiring AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Semper Solaris 6197286511 613 W BELL AVESANTA ANA CA 92707 PETE M ABASCAL SOLAR 8.8 AC 613 W Bell Ave 03/20/23 January 25, 2023 To Whom It May Concern: I would like to have Semper Solaris install our Solar. Please let me know if you need anything else. I would like to have Semper Solaris install our solar. Thank you. Pedro Abascal Signature ______________________________________________________________Pedro Abascal (Jan 25, 2023 15:24 PST) 613 W Bell 613 W Bell Ave 03/20/23 79275 Abascal Installation Request Letter Final Audit Report 2023-01-25 Created:2023-01-25 By:Richard Charron (matuzdad@hotmail.com) Status:Signed Transaction ID:CBJCHBCAABAAhCb_c6CuQVrdPwGLZGkDdepvbyNR-ypl "79275 Abascal Installation Request Letter" History Document created by Richard Charron (matuzdad@hotmail.com) 2023-01-25 - 11:02:09 PM GMT- IP address: 70.125.23.154 Document emailed to lacsaba@aol.com for signature 2023-01-25 - 11:02:29 PM GMT Email viewed by lacsaba@aol.com 2023-01-25 - 11:19:27 PM GMT- IP address: 172.226.184.1 Signer lacsaba@aol.com entered name at signing as Pedro Abascal 2023-01-25 - 11:24:06 PM GMT- IP address: 107.77.228.81 Document e-signed by Pedro Abascal (lacsaba@aol.com) Signature Date: 2023-01-25 - 11:24:08 PM GMT - Time Source: server- IP address: 107.77.228.81 Agreement completed. 2023-01-25 - 11:24:08 PM GMT 613 W Bell Ave 03/20/23 STRUCTURAL CALCULATIONS FOR PEDRO ABASCAL 613 W BELL AVE SANTA ANA CA 92707 ENGINEER: BWU Consultants, Inc 1168 San Gabriel Blvd #N Rosemead, CA 91770 613 W Bell Ave 03/20/23 DESIGN DATA 1. CODE: 2022 CALIFORNIA BUILDING CODE ASCE 7-16 2. MATERIAL STRENGTH CONCRETE: Fc’ = 2,500 PSI @ 28 DAYS CONCRETE REBAR: ASTM A615 GRADE 40 Fy = 40,000 PSI STEEL: (AISC 360) 13 EDITION STRUCTURAL SHAPES: ASTM A36 Fy = 36 KSI TUBING: STM A500 GRADE B Fy = 46 KSI PIPE: ASTM A53 TYPE E GRADE B Fy = 35 KSI WOOD: DOUGLAS FIR-LARCH ( 19% MAX. M.C. ) JOIST & RAFTER #2 GRADE Fb = 875 PSI Fv = 95 PSI E = 1.6 x 1,000,000 BEAM & HEADER (4X) #1 GRADE Fb = 1,000 PSI Fv = 95 PSI E = 1.7 x 1,000,000 (6X) #1 GRADE Fb = 1,000 PSI Fv = 85 PSI E = 1.7 x 1,000,000 POST (4X) #1 GRADE Fb = 1,000 PSI Fv = 95 PSI E = 1.6 x 1,000,000 (6X) #1 GRADE Fb = 1,000 PSI Fv = 85 PSI E = 1.7 x 1,000,000 STUD #2 GRADE Fb = 675 PSI Fv = 95 PSI E = 1.4 x 1,000,000 SELECT STRUCTURAL (6x, LARGE) Fb = 1,450PSI Fv = 95 PSI E = 1.9 x 1,000,000 MASONRY: CONCRETE BLOCK ASTM C90 Fm = 1500 PSI NO INSPECTION REQUIRED 3. SOIL REPORT: f’s= 1,500 PSF/ OR SEE SOILS REPORT 4. LATERAL ANALYSIS: A. SEISMIC LOAD W CV SSEE ATTACHED. B. WIND LOAD (SIMPLIFIED PROCEDURE) (130 mph) EXP “C” ULTIMATE 613 W Bell Ave 03/20/23 613 W Bell Ave 03/20/23 BWU Consultants, Inc. 1168 N. San Gabriel Blvd., #N Rosemead, CA. 91770 Tel: (626) 288-0708 Email: twengrs1168@gmail.com Date: D.L.SIZE: SHINGLE ROOF'G 4 psf 18.0 SQ.FT. 1/2" PLYWD SHT'G 1.5 2x6 @ 24 O.C.1.1 RAFTER MISC 0.4 WEIGHT: D.L. = WT = 2.9#/SQ.FT. L.L. = (USE 3.0 #/SQ.FT.) T.L. = L:7'-0" MAX SPAN W:60.0 plf M:367.5 pf Sreq: 2.7 in³ R:210 lb Areq: 2.65 in² 2x6 RAFTER CAN CARRY SOLAR PANELS GRAVITY PER 2022 CALIFORNIA EXISTING BLDG CODE. PART 10. SECTION 502.4 & 503.314 x 3 x 18 =756 lb 41720 lb 756 / 41720 =1.8% (7+3+20) x 24/12 = (2022 CALIFORNIA BUILDING CODE) ASCE 7-16 EXIST'G ROOF LOAD'G (AS BUILT)SOLAR PANEL 30.0 psf 20.0 psf 7.0 psf (ROOF DL 7 + CL'G DL 5 + PART'N 16/2) x 2086 = 613 W Bell Ave 03/20/23 WIND LOAD (RISK CATEGORY III,IV) 130 MPH, EXP ”C” CHAP 26.10.2 - WIND LOAD COMPONENTS & CLADDING (C&C) qz= .00256 Kz Kzt Kd V2 I (26-10-1) Ht. z at the centroid of area Af = 10 ft Exp = Exposure coefficient Kz = 0.85 c (TABLE 26.8-1) Topography factor Kzt = 1.00 (FIGURE 26.8-1) Directionality factor Kd = 0.85 Wind Speed V = 130 mph Importance factor Iw = 1.00 qz = 0.00256 x 0.85 x 1.0 x 0.85 x (130)2 = 31.26 psf Gust Effect factor G = 0.85 Force coeff Cf = 1.31 Design wind pressure, F/Af = 31.26 x 0.85 x 1.31 = 34.81 psf ASCE 7-16 613 W Bell Ave 03/20/23 BWU Consultants, Inc. 1168 N. San Gabriel Blvd., #N Rosemead, CA. 91770 Tel: (626) 288-0708 Email: twengrs1168@gmail.com Date: UPLIFT / WITHDRAWAL FORCE FOR SOLAR PANEL STANDOFF / FAST JACK Vup= 34.81 lb/sq.ft SEISMIC PER 2022 CALIFORNIA EXISTING BLDG CODE. PART 10. SECTION 502.5 & 503.4 756 lb / 41720 lb = 1.8% < 10.0% OK Vall = 274 x 2.5 = 685 lb > 438.6 lb OK O.K. USE 5/16"ø X 3 1/2" LONG STAINLESS STEEL LAG SCREW WITH MIN. 2 1/2" EMBED TO EXIST'G ROOF MEMBER. CAN RESIST WIND UPLIFT FORCE. LATERAL (2022 CALIFORNIA BUILDING CODE) WIND EXP "C", WIND SPEED: 130 mph (ASCE 7-16) 20 438.6 lb/lag screw NO. SOLAR PANELS UPLIFT FORCE SUPPORTS OF TILE HOOK/STANDOFF UNIT FORCE PER (5/16"ø) LAG SCREW 14 14 x 34.81 x 18 = 8772.12 lb 613 W Bell Ave 03/20/23 613 W Bell Ave 03/20/23 613 W Bell Ave 03/20/23 613 W Bell Ave 03/20/23 01231456178918 2388  !" #$ %& '# #( #!) ! *+# ) , -./ 0 11 23) 2 4!015) ) 3!1(  %& 6327! + 869 03!$31)# $ ! +03!! 03! :5"2 ! !3 # $!*1 !013$5+ #!) $+ #21! $ %& 20+3!; + +$ #!) $3+#* !$#11#3!$ 7( "+3;)!* # 03!$$ !< "+ -+ ) $3153! =3+ + $) !#1 #""10#3!$> % 3== +$ 5" 3 =35+ ?-"31 !"5 0+05$ #!) #3! @A $ + $ 75$7#+ #$$ 271(>  2388 01231456 1789 18 01231456 1789 18 BCDEFGHIDJCHFDGKCLMDNIOPGQFDCRRFHSITQUDVSQSMDWXYZ[\W]^_` a## b  cdefg hJGHM iDDjIkELlFQDjmDnGMFoGpDRCHDkCJJLISkGMSCIDGIlDkCIMHCE iDDjIkELlFQDNIOPGQFDqCKSEFDrCIIFkMDkFEELEGHDJClFJD srNttquvNqwqx wyz wh{wy|}UDSIkELlFlDCIEpDoSMPDjmD rCJKSIFHD~r iDDjIkELlFQDQCEGHDQPSFElDMCDJGMkPDNIOPGQFDjmDGMMFHpD €‚ƒ„ƒ…†‚‡€ˆ‰‡‰Š†ƒ‡„€ƒ iDD‹EFŒSKEFDIFMoCHSITDQLOOCHMQDŽSw‹SUDD NMPFHIFMUDCHDkFEELEGH iDDuOMSCIGEDrDHFkFOMGkEFDGVGSEGKEFDRCHD{trDKHSl TF iDD{HCVSl FQDOHClLkMSCIDJFMFHSITDGIlDkCIQLJOMSCID JCISMCHSIT hSJOEF iDrFIMFHFlDJCLIMSITDKHGkFMQDQLOOCHMDQSITEFDD QMLlDJCLIMSIT iDhLOOCHMQDKCMMCJUDKGkDGIlDQSlFDkCIlLSMDFIMHp iDODMCDRCLHD‘wOCEFDKHGIkPDkSHkLSMQDRCHD‘~yD’rDD OELT wSIDKHFGFHQDsICMDSIkELlFl } iD“yDMCMGED{’DCHDQMCHGTFDKHGIkPDkSHkLSMQ ”FESGKEF •‡–—˜€™š‡›œžŸ†˜ƒ… ‰‡›¡¢£‡ƒ¤¥‡¦œ‡ˆ†š§‚—˜ iD‹SVFwpFGHDESJSMFlDoGHHGIMp iDBoCDpFGHQDEGKCHDHFSJKLHQFJFIMDOHCTHGJDkCVFHGTFD SIkELlFlDRCHDKCMPDMPFDjmDrCJKSIFHDh¨©Q iDtDESQMFl 01231456178918 BCDEFGHIDJCHFDGKCLMDNIOPGQFDCRRFHSITQUDVSQSMDWXYZ[\W]^_` ª ?«?/ !" #$ ! +*(> ¬11 +* $ + $ +; )> !" #$ <  !" #$ 13*3< %& 6327! + 8­86< #!) 3 + !#2 $ #+ +#) 2#+®$ 3= !" #$ ! +*(< %!0> a## $57¯ 0 3 0 #!* > /«-?/-?«?/ °±²³´µ¶·°¸³¹ jmDrCJKSIFHD~DDsºwjmwqx w‘~yw~}jmDrCJKSIFHD~DoSMPDNIOPGQFDjmDnGMFoGpDOHSIMFlDkSHkLSMDKCGHlDRCHDSIMFTHGMFlDHFVFILFDTHGlFD{’DOHClLkMSCIDJFMFHSITDs»hjD rx ‘¼‘yD½¾wDy¼|¿}DGIlDkCIQLJOMSCIDJCISMCHSITDs½¾wD‘¼|¿}¼DjIkELlFQDGDQSEVFHDQCEGHDQPSFElDMCDJGMkPDMPFDjmDGMMFHpDQpQMFJDGIlD ÀÁ‡Â¤‚ƒÃ‡Ä§ˆƒ˜§šš˜‡Å‡€ˆ‰‡ƒ§‡‰Š†ƒ‡„€ƒÆ jmDrCJKSIFHD~rDsºwjm wqx w‘~yw~r}jmDrCJKSIFHD~rDoSMPDNIOPGQFDjmDnGMFoGpDOHSIMFlDkSHkLSMDKCGHlDRCHDSIMFTHGMFlDHFVFILFDTHGlFD{’DOHClLkMSCIDJFMFHSITD s»hjDrx‘¼‘yD½¾wDy¼|¿}DGIlDkCIQLJOMSCIDJCISMCHSITDs½¾wD‘¼|¿}¼DjIkELlFQDNIOPGQFDqCKSEFDrCIIFkMDkFEELEGHDJClFJD srNttquvNqwqx wyzwh{wy|}UDGDOELTwGIlwOEGpDSIlLQMHSGEwTHGlFDkFEEDJClFJDRCHDQpQMFJQDLODMCDzyDJSkHCSIVFHMFHQ¼D sVGSEGKEFDSIDMPFDhUDrGIGlGUDqFŒSkCUD{LFHMCD”SkCUDGIlDMPFDhD’SHTSIDjQEGIlQUDoPFHFDMPFHFDSQDGlFÇLGMFDkFEELEGHDQFHVSkFDSID ƒ„‡…ˆ‚ƒ€šš€ƒ…§ˆ‡€˜€ÆÈ‡Àˆ†š—‰‚‡€‡‚…šÉ˜‡‚§š€˜‡‚„…š‰‡ƒ§‡Ã€ƒ†„‡ƒ„‡ÀÁ‡Ê€ƒƒ˜¤‡€ˆ‰‡ÀÁ‡Â¤‚ƒÃ‡Ä§ˆƒ˜§šš˜‡‡€ˆ‰‡ƒ§‡‰Š†ƒ‡„€ƒÆ ËÌ Ì ³Í Í ±¹Î ³ÍµË ¶²µ¹³Ï ´ËÌ ³°³¶ÐµÏ˹ÐÍ sICMDSIkELlFlUDCHlFHDQFOGHGMFEp} NIQFJKEFDrCJJLISkGMSCIQD¨SMDD ruqqhwrNttquvNqwqx wyzD rNttquvNqwqx wyzwh{wy|D rNttquvNqwqx wyzwBwy|D wDjIkELlFQDruqqhw¨jBwyx DGIlDrNttquvNqwqx wyzwh{wy|DoSMPD|wpFGHDhOHSIMDlGMGDOEGIDRCHD DDDNIQFJKEFDQSMFQ wD~nDKGQFlDtBNwqx DkFEELEGHDJClFJDoSMPD|wpFGHDhOHSIMDlGMGDOEGI wD~nDKGQFlDtBNwqx DkFEELEGHDJClFJDoSMPD|wpFGHDBÑBDlGMGDOEGI rSHkLSMDHFGFHQ DD”¨wx yw‘w‘~y’ DD”¨wx |w‘w‘~y’ DD”¨w‘yw‘{w‘~y’ DD”¨wx |w‘{w‘~y’w DD”¨w‘yw‘{w‘~y’w —¥¥§˜ƒ‚‡¡€ƒ§ˆ‡ÊœÅÒ ÓԇʜÅÒ ÕԇʜÅÅÓԇʜŦÓԇʜÅÖÓԇʜÅÕÓԇ€ˆ‰‡ÊœÅ×Ӈ†…˜†—…ƒ‡™˜€Ø˜‚Æ DDrSHkLSMDKHFGFHUD‘DOCEFUDxyUDNGMCID”‘x yD DDrSHkLSMDKHFGFHUD‘DOCEFUDx|UDNGMCID”‘x | DDrSHkLSMDKHFGFHUD‘DOCEFUD‘yUDNGMCID”‘‘yD DDrSHkLSMDKHFGFHUD‘DOCEFUDx|UDNGMCID”‘x |DoSMPDPCElDlCoIDSMDQLOOCHM DDrSHkLSMDKHFGFHUD‘DOCEFUD‘yUDNGMCID”‘‘yDoSMPDPCElDlCoIDSMDQLOOCHM N{trwyx {CoFHDESIFDkGHHSFHDskCJJLISkGMSCIDKHSl TFDOGSH}UDÇLGIMSMpDwDCIFDOGSH ºwhut”hÙjNtvwNh ”FOEGkFJFIMDQCEGHDQPSFElDRCHDjmDrCJKSIFHD~¾~r Ú£ŸÛžÜÝ ŸÒ Åӟ¦kkFQQCHpDHFkFOMGkEFDRCHD{CoFHDtSIFDrGHHSFHDSIDjmDrCJKSIFHD~¾~rDsHFÇLSHFlDRCHDN{trwyx } Ú£Ÿ¡›ÞŸÛÄÊ£Ÿ¦”FOEGkFJFIMDjmDnGMFoGpDOHSIMFlDkSHkLSMDKCGHlDs{r}DRCHDrCJKSIFHD~¾~r ºwjmw»wÙv wx ‘|ÙCElDlCoIDSMDRCHDNGMCIDkSHkLSMDKHFGFHDoSMPDQkHFoQ¼ ³´³Ì йΠÌË´µÍ Ï³Ì Î ßÎ Ì ËÐÎ ±¶Í ”GMSIT rCIMSILCLQDlLMp hpQMFJDVCEMGTF x‘y¾‘~yD’rUDzyDÙà NGMCID”DQFHSFQDKLQKGHDHGMSIT x‘|D qGŒ¼DkCIMSILCLQDkLHHFIMDHGMSIT z|D qGŒ¼DkCIMSILCLQDkLHHFIMDHGMSITDsSIOLMDRHCJD{’¾QMCHGTF}z~D qGŒ¼DRLQF¾kSHkLSMDHGMSITDsCLMOLM}áyD HGIkPDkSHkLSMQDsQCEGHDGIl¾CHDQMCHGTF}ODMCDRCLHD‘wOCEFDNGMCID”DQFHSFQDvSQMHSKLMFlDnFIFHGMSCIDsvn}DKHFGFHQDCIEpDsICMDSIkELlFl } qGŒ¼DMCMGEDKHGIkPDkSHkLSMDKHFGFHDHGMSITDsSIOLM}“yDCRDlSQMHSKLMFlDTFIFHGMSCID¾Dá|DoSMPDjmDnGMFoGpDKHFGFHDSIkELlFl {HClLkMSCIDJFMFHSITDrB ‘yyDDQCESlDkCHFDOHFwSIQMGEEFlDGIlDoSHFlDMCDjmDnGMFoGp rCIQLJOMSCIDJCISMCHSITDrBDsrBw‘yywh{tjB}DOGSHDCRD‘yyDDQOESMDkCHFDkLHHFIMDMHGIQRCHJFHQD °³Ì â ˶ΠÌË ´µ²ËÐË vSJFIQSCIQDsŽŒÙŒv}¦ãÆÕ‡ä‡ÖåÆÕ‡ä‡Ò ×Ææ‡†Ã‡çÒ ÖÆãÕè‡ä‡Ò åÆÕè‡ä‡×Æ×¦èÈÆ‡é…ꄃ‡…‚‡ÅÒ ÆÓ×ë‡çÕ¦ÆÕ‡†Ãȇ셃„‡Ã§—ˆƒ…ˆê‡™˜€†Øƒ‚Æ ŽFSTPM ãÆÕ‡Øê‡çÒ ×ÆÕ‡š™‚È JKSFIMDMFJOFHGMLHFDHGIT F w~yíDrDMCD½~zíDrDsw~yíDMCDxx|íD‹} rCCESIT »GMLHGEDkCIVFkMSCIUDOELQDPFGMDQPSFEl NIkECQLHFDFIVSHCIJFIMGEDHGMSIT ‰§§˜Ô‡›œžŸ†˜ƒ… ‰Ô‡›¡¢£‡ƒ¤¥‡¦œÔ‡¥§š¤†€˜™§ˆ€ƒ‡†§ˆ‚ƒ˜—†ƒ…§ˆ ŽSHFDQSàFQ iDD‘yDDMCD|yDDKHFGFHDSIOLMQïDx~DMCD~DŽnDkCOOFHDkCIlLkMCHQ iDDzyDDKHFGFHDKHGIkPDSIOLMïD~DMCDx¾yDŽnDkCOOFHDkCIlLkMCHQ iDDqGSIDELTDkCJKSIFlDCLMOLMïDxyDMCD‘¾yDŽnDkCOOFHDkCIlLkMCHQ iDD»FLMHGEDGIlDTHCLIlïDx~DMCDx¾yDkCOOFHDkCIlLkMCHQ EoGpQDRCEECoDECkGEDkClFDHFÇLSHFJFIMQDRCHDkCIlLkMCHDQSàSIT¼ EMSMLlF BCD‘yyyDJFMFHQDszU|zyDRFFM} Î ¶Ð³¹¶³ÐµÌ ±¶¶³Ì Ð Î ±¶µ±ÏÐ Î ±¶Í jIMFTHGMFlDŽSw‹S “y‘¼xx K¾T¾I rFEELEGH rNttquvNqwqx wyzwh{wy|UDrNttquvNqwqx wyzwBwy|Ds~nDKGQFlDtBNwqx DkFEELEGHDJClFJ}¼DD»CMFDMPGMDGIDNIOPGQFD qCKSEFDrCIIFkMDkFEELEGHDJClFJDSQDHFÇLSHFlDRCHDGEEDNIQFJKEFDSIQMGEEGMSCIQ¼ NMPFHIFM …§ˆ€šÔ‡æÓÅÆ¦Ô‡Ä€ƒÕ¡‡ç§˜‡Ä€ƒ‡×ȇܝۇ¡ƒ„˜ˆƒ‡†€™š‡‡çˆ§ƒ‡…ˆ†š—‰‰È Ì ±°Ï ´Î Ë ¶Ì ³ rCJOESGIkFUDjmDrCJKSIFH ܞ‡Ò ãÖÒ Ô‡Ä£›ðÄ£‡ÄÅůқ§Æ‡Ò ÓãÆÒ ԇ‡Öã‡ÄñœÔ‡Û€˜ƒ‡Ò Õԇ̀‚‚‡ÊԇÀġ‡ÓÓ¦ {HClLkMSCIDJFMFHSITïD»hjDrx ‘¼‘yDGkkLHGkpDkEGQQDy¼|Ds{’DOHCl LkMSCI} rCIQLJOMSCIDJFMFHSITïDGkkLHGkpDkEGQQD‘¼| rCJOESGIkFUDjmDnGMFoGp tDzyzyx wx ¾r»rhD‘‘¼‘D»C¼Dzx yx y wx D 2388 613 W Bell Ave 03/20/23 613 W Bell Ave 03/20/23 613 W Bell Ave 03/20/23 613 W Bell Ave 03/20/23 613 W Bell Ave 03/20/23 ACC MSPLC ACD AC C E S S P A T H 3 ' 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK AC C E S S P A T H 3 ' E2 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d ENPH DESIGN 01-02-2023 79275 5.60 PE T E M A B A S C A L SA N T A A N A C A 9 2 7 0 7 61 3 W B E L L A V E (7 1 4 ) 8 6 5 - 0 4 6 6 41 0 1 9 5 0 6 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 5. 6 0 k W D C P V SCALE: SITE PLAN N 3/16" = 1'-0" LEGEND 14 (N) HANWHA Q.PEAK DUO BLK ML-G10+ 400 SOLAR MODULES EACH WITH A (N) ENPHASE IQ8M-72-2-US MICRO-INVERTER (FLUSH MOUNT) MSP ACC (N) 125A ENPHASE IQ COMBINER 4C WITH ENVOY IQ, CELL MODEM, & WIRELESS COMMUNICATIONS KIT (E) 100A BUS NCF (E) 100A MAIN BREAKER INSTALL (N) 70A BRANCH BREAKER TO FEED (N) 125A LC SERVICE POINT & UTILITY METERING LC (N) 125A LOAD CENTER (N) 70A MAIN BREAKER (TO HOUSE ALL LOADS CURRENTLY IN THE MSP) ACD (N) 30A AC DISCONNECT 613 W Bell Ave 03/20/23 ACC MSPLC ACD RP 1 AC C E S S P A T H 3 ' 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK AC C E S S P A T H 3' TILT AZIMUTH 180°22.3° E5 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d ENPH DESIGN 01-02-2023 79275 5.60 PE T E M A B A S C A L SA N T A A N A C A 9 2 7 0 7 61 3 W B E L L A V E (7 1 4 ) 8 6 5 - 0 4 6 6 41 0 1 9 5 0 6 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 5. 6 0 k W D C P V SCALE: ROOF PLAN N 1/8" = 1'-0" NEW PV CONDUIT TO BE RUN UNDER EVE WHENEVER POSSIBLE. ANY PROPOSED CONDUIT RUN SUBJECT TO CHANGE BY INSTALLER. 20 ATTACHMENTS INSTALLED @ 72" O.C. MAX (TYP) 2x6 RAFTER @ 24" OC TYP COMP SHINGLES ROOFING FRONT OF RESIDENCE ARRAY AREA & ROOF AREA CALCULATIONS ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) 296.00 2086.17 14.19 613 W Bell Ave 03/20/23 (N) MODULE (E) COMPOSITION SHINGLE (E) ROOF DECKING (E) RAFTER, SEE E5 FOR DETAIL (N) PEGASUS MULTI CLAMP (N) PEGASUS RAIL (N) PEGASUS DOVETAIL T-BOLT (N) PEGASUS L-FOOT (N) 5/16" x 4.5" PEGASUS LAG BOLT MIN 2.5" EMBEDMENT (N) PEGASUS COMP MOUNT FLASHING E6 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d ENPH DESIGN 01-02-2023 79275 5.60 PE T E M A B A S C A L SA N T A A N A C A 9 2 7 0 7 61 3 W B E L L A V E (7 1 4 ) 8 6 5 - 0 4 6 6 41 0 1 9 5 0 6 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 5. 6 0 k W D C P V ATTACHMENT DETAIL 613 W Bell Ave 03/20/23 ACC MSPLC ACD JHA SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d ENPH DESIGN 01-02-2023 79275 5.60 PE T E M A B A S C A L SA N T A A N A C A 9 2 7 0 7 61 3 W B E L L A V E (7 1 4 ) 8 6 5 - 0 4 6 6 41 0 1 9 5 0 6 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 5. 6 0 k W D C P V NEAREST URGENT CARE VICINITY MAP DISTANCE ADDRESS NAME CONDITIONS NCREW MEMBER CREW LEAD CREW MEMBER CREW MEMBER ROPE REACH LADDER ACCESS CONES EXCLUSION ZONE JHA LEGEND ANCHOR POINTS N THIS PAGE TO BE COMPLETED BY INSTALLATION CREW 613 W Bell Ave 03/20/23 613 W Bell Ave 03/20/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Ketan 613 W Bell Ave 03/20/23