Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
825 E Clemensen Ave - Plan
03/31/2023 To whom it may concern, I have purchased solar with TMAG Industries (dba: Stellar Solar) and they have my full permission/approval to install solar on my property. 825 Clemensen Ave, Santa Ana, CA, 92705 Best regards, Gerald Tiritilli (Apr 1, 2023 11:42 PDT) 825 E Clemensen Ave04/26/23 Permit permission doc Final Audit Report 2023-04-01 Created:2023-03-31 By:Frida Mock (fridam@stellarsolar.net) Status:Signed Transaction ID:CBJCHBCAABAA1eW-W7GEP_MQXajWfzcWJDdvu65VXr3l "Permit permission doc" History Document created by Frida Mock (fridam@stellarsolar.net) 2023-03-31 - 6:56:52 PM GMT- IP address: 45.50.134.149 Document emailed to gerald.tiritilli@icloud.com for signature 2023-03-31 - 6:58:24 PM GMT Email viewed by gerald.tiritilli@icloud.com 2023-04-01 - 6:40:18 PM GMT- IP address: 166.199.151.73 Signer gerald.tiritilli@icloud.com entered name at signing as Gerald Tiritilli 2023-04-01 - 6:42:29 PM GMT- IP address: 166.199.151.73 Document e-signed by Gerald Tiritilli (gerald.tiritilli@icloud.com) Signature Date: 2023-04-01 - 6:42:31 PM GMT - Time Source: server- IP address: 166.199.151.73 Agreement completed. 2023-04-01 - 6:42:31 PM GMT Names and email addresses are entered into the Acrobat Sign service by Acrobat Sign users and are unverified unless otherwise noted. 825 E Clemensen Ave04/26/23 PV-1 PROJECT NO. DATEREVISION LICENSE NUMBER 749095 C-10 DATE: //2023 TI R I T I L L I , G E R A L D 82 5 C L E M E N S E N A V E . , SA N T A A N A , C A , 9 2 7 0 5 PH O N E : ( 7 1 4 ) 5 0 4 - 2 8 9 9 LE G A L D E S C R I P T I O N / A P N : 3 9 6 - 4 1 1 - 1 9 DRAWN BY: CLEMENSEN AVE CONDUIT RUN ON ROOF / UNDER EAVE EXISTING 100A MAIN SERVICE PANEL (100A MCB) CAL-FIRE WALKWAY Scale: 1" = 20' SITE MAP 1 00 20' 40' NORTH BATTERY / PV DISCONNECT (NEXT TO MSP) STRING 13 STRING 26 ROOF ACCESS POINT BATTERY W / INTEGRATED INVERTER, RAPID SHUTDOWN FOR PV / ESS, MICRO GRID SUB-PANEL & GATEWAY-2 (EXTERIOR WALL) ARRAY 3 (3) HANWHA QCELLS Q.PEAK DUO BLK ML-G10 405 MODULES MOUNTED FLUSH TO ROOF ROOF SLOPE = 18 AZIMUTH = 245 ROOF ACCESS POINTS SHALL BE PROVIDED PER THE FOLLOWING (CRC R324.6) ROOF ACCESS AND PATHWAYS: ROOF ACCESS, PATHWAYS AND SETBACKS REQUIREMENTS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R324.6.1 THROUGH R324.6.2.1 ACCESS AND MINIMUM SPACING SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF, TO PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF, PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS, AND TO PROVIDE EMREGENCY EGRESS FROM THE ROOF. PL PL PLPL 1'-6" 1'-6"ARRAY 1 (2) HANWHA QCELLS Q.PEAK DUO BLK ML-G10 405 MODULES MOUNTED FLUSH TO ROOF ROOF SLOPE = 18 AZIMUTH = 155 ARRAY 2 (4) HANWHA QCELLS Q.PEAK DUO BLK ML-G10 405 MODULES MOUNTED FLUSH TO ROOF ROOF SLOPE = 9 AZIMUTH = 155 825 E Clemensen Ave04/26/23 PV-2.1 PROJECT NO. DATEREVISION LICENSE NUMBER 749095 C-10 DATE: //2023 TI R I T I L L I , G E R A L D 82 5 C L E M E N S E N A V E . , SA N T A A N A , C A , 9 2 7 0 5 PH O N E : ( 7 1 4 ) 5 0 4 - 2 8 9 9 LE G A L D E S C R I P T I O N / A P N : 3 9 6 - 4 1 1 - 1 9 DRAWN BY: 1 LEGEND: 1. TESLA POWERWEALL+ PLUS 2. TESLA GATEWAY-2 3. 200A MICRO GRID SUB-PANEL 4. BATTERY / INVERTER DISCONNECT 5. ELECTRICAL GUTTER BOX 6. RAPID SHUTDOWN DEVICE 23 4 5 EXISTING 100A MAIN SERVICE PANEL, W / 100A MCB (NON BACKUP PANEL) DESCRIPTION BREAKER SIZE POLE MAIN BREAKER 100 2 GATEWAY - 2 100A 2 CIRCUIT BREAKERS IN THIS PANEL WILL NOT HAVE BACKUP POWER NEW 200A MICRO-GRID SUB-PANEL W / 100A MCB (BACKUP PANEL) DESCRIPTION BREAKER SIZE POLE MAIN BREAKER 100 2 FAMILY RM 20 1 LIGHTS & PLUGS 20 1 DISPOSAL 20 1 OUT OF SERVICE 20 1 LIGHTS & PLUGS 20 1 LIGHTS & PLUGS 20 1 SPARE 30 2 N/A 30 2 SPARE 30 2 STOVE 50 2 LIGHTS & PLUGS 15 1 LIGHTS & PLUGS 15 1 LIGHTS & PLUGS 20 1 LIGHTS & PLUGS 20 1 REFER 20 1 MICRO 20 1 CIRCUIT BREAKERS IN THIS PANEL WILL HAVE BACKUP POWER TESLA GATEWAY-2 MLO BREAKER SIZE POLE BACKUP#1 MICRO GRID PANEL M.L.O.2 BACKUP#2 TESLA POWERWALL+50 2 NON-BACKUP 6' 11" 6'-2" 6 825 E Clemensen Ave04/26/23 PV-2 PROJECT NO. DATEREVISION LICENSE NUMBER 749095 C-10 DATE: //2023 TI R I T I L L I , G E R A L D 82 5 C L E M E N S E N A V E . , SA N T A A N A , C A , 9 2 7 0 5 PH O N E : ( 7 1 4 ) 5 0 4 - 2 8 9 9 LE G A L D E S C R I P T I O N / A P N : 3 9 6 - 4 1 1 - 1 9 DRAWN BY: Scale: 1/8" = 1' ENLARGED ROOF PLAN2 Scale: NTS SOLAR MOUNTING DETAIL - A 1 ECOFASTEN CLICK FIT RAIL (22) ECOFASTEN COMP. FOOTINGS MAX 6' SPAN BETWEEN FOOTINGS 1LB EXISTING 2"x8" ROOF RAFTER 24" O.C. NOTES: · PANEL ASSEMBLY WILL BE ATTACHED TO THE EXISTING ROOF BY THE CONSTRUCTION OF A STRUCTURAL FRAME TO CONSIST OF ECOFASTEN CLICK FIT RAIL & ECOFASTEN GREENFASTEN FLASHING COMP. ·LAG SCREWS SHALL BE AT LEAST 6" FROM ANY TRUSS JOINT. ·SOLAR PANELS ATTACHED TO RAIL WITH MODULE MOUNTING CLIP AND 1/4" NUTS & BOLTS ·ROOF PENETRATIONS WILL BE SECURE AND WEATHER TIGHT WITH RUBBERIZED ELASTOMAT SEALER AND FLASHING. ·ARRAY WEIGHT = 2.9 LBS/SQFT ·LBS PER FOOTING = 26.0 ·UL2703 & UL467 (9) HANWHA QCELLS Q.PEAK DUO BLK ML-G10 405 MODULES 74.0" x 41.1" 48.5LBS MODULE ECOFASTEN CLICK FIT RAIL END/MID CLAMPS ECOFASTEN GREENFASTEN FLASHING COMP. 5/16" x 4" LAG SCREW INTO EXISTING 2X8 RAFTER MIN. 2-1/2" EMBEDMENT. ROOF COMPOSITE SHINGLES 4" 12'-4" 3'-5" 2'-11" 8'-3" 5" 9'-7" 2'-6" 4'6' 6'-2" 6'-2" 6" 10'-5"6'-7" 4' 825 E Clemensen Ave04/26/23 PV-3 PROJECT NO. DATEREVISION LICENSE NUMBER 749095 C-10 DATE: //2023 TI R I T I L L I , G E R A L D 82 5 C L E M E N S E N A V E . , SA N T A A N A , C A , 9 2 7 0 5 PH O N E : ( 7 1 4 ) 5 0 4 - 2 8 9 9 LE G A L D E S C R I P T I O N / A P N : 3 9 6 - 4 1 1 - 1 9 DRAWN BY: (3) #1 XHHW-2 (1) #6 GND SE CABLE (ALUMINUM) OR EQUAL (3) #2 THWN-2 (1) #8 GND (COPPER) IN 1-1/4" E.M.T. / PVC B A B A B A B A #3 #1 (4) #10 THWN-2 (1) #10 GND 1/2" E.M.T. / F.M.C #10 PV WIRE (1) #6 GND TO J-BOX TESLA POWERWALL+ BATTERY & SOLAR INVERTER MP P T - 1 MP P T - 2 MP P T - 3 MP P T - 4 200A TESLA BACKUP GATEWAY, MAIN LUG ONLY (N) 200A MICROGRID SUBPANEL W/ 100A MCB THE RACKING SYSTEM IS LISTED TO UL 2703 FOR INTEGRATED GROUNDING; MODULES ARE AN ELECTRICAL BONDING COMPONENT AND ARE LISTED TO UL 1741; THUS NO ADDITIONAL GROUNDING HARDWARE, LUGS, OR COPPER WIRE ARE REQUIRED ON THE ROOF. NE M A 3 R J - B O X O N R O O F B A B A B A B A #6 #1 100A 50A (3) #8 THWN-2 (1) #8 GND W/ TESLA COMMS. (~5') 1" E.M.T. / F.M.C / L.F. NEC 705.12 (B)(2)(3)(C) SUM RULE PANEL = 100A GATEWAY-2 = 100A 100A = 100A NO OTHER BREAKER INSTALLED IN THIS PANEL SUM RULE BACKUP NON-BACKUP EXISTING 100A MAIN SERVICE PANEL W/ 100A MCB 100A MCB EXISTING HOME GROUNDING SYSTEM (2) #14 THWN-2 1/2" E.M.T. / F.M.C. RAPID SHUTDOWN DEVICE 100A (N) 60A BATTERY / PV DISCONNECT STRING -1 MPPT - 1 STRING -2 MPPT - 2 (9) HANWHA QCELLS Q.PEAK DUO BLK ML-G10 405 W/ (3) TESLA MCI'S STRING 1 - (3) MODULES, (1) MCI'S STRING 2 - (6) MODULES, (2) MCI'S CONNECT MCI AFTER EVERY 3 MODULES (1) MCI FOR EVERY 165V MAX OF (5) MCI'S PER STRING THIS PANEL IS RATED @ 75°825 E Clemensen Ave04/26/23 PROJECT NO. DATEREVISION LICENSE NUMBER 749095 C-10 DATE: //2023 TI R I T I L L I , G E R A L D 82 5 C L E M E N S E N A V E . , SA N T A A N A , C A , 9 2 7 0 5 PH O N E : ( 7 1 4 ) 5 0 4 - 2 8 9 9 LE G A L D E S C R I P T I O N / A P N : 3 9 6 - 4 1 1 - 1 9 DRAWN BY: ATTACH TO MICRO GRID PANEL (NEC 408.4) THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVER CURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED BUSBAR. ATTACH TO MAIN PANEL ATTACH TO MAIN PANEL (NEC 705.12.B.3.c) WARNING ATTACH TO ENERGY STORAGE SYSTEM CEC 706.7(D) NOMINAL VOLTAGE: MAX SHORT-CIRCUIT CURRENT: ARC FLASH CLEARING TIME: DATE OF CALCULATION: ESS DISCONNECT 240 VOLTS 45 AMPS 67 MS 03/02/2023 BACK UP LOAD CENTER ENERGY STORAGE SYSTEM ON SITE LOCATED INSIDE ATTACH TO BATTERY DISCONNECT 706.15(C) ENERGY STORAGE SYSTEM DISCONNECT ELECTRICAL NOTES: · ALL PLAQUES AND SIGNAGE REQUIRED BY THE 2022 EDITION OF CALIFORNIA ELECTRICAL CODE AND THE AHJ AREA ELECTRICAL NEWSLETTER, WILL BE INSTALLED AS REQUIRED. · ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC WITH ENGRAVED LETTERING IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTACHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHOD. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. · EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136 (A) REGARDLESS OF VOLTAGE. ·IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. ·ACCESS TO DC WIRING WILL BE RESTRICTED TO QUALIFIED PERSONAL ONLY. ·NEW BACK FED PV BREAKER SHALL BE POSITIONED AT OPPOSITE END OF MAIN BREAKER. ·BACK-FED CIRCUIT BREAKER SHALL COMPLY WITH CEC ART. 690.10, 705.15(E) AND 408.36 (D). ·PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN A METALLIC RACEWAY AND SHALL BE IDENTIFIED EVERY 10 FEET WITH MINIMUM 3/8 INCH HIGH WHITE LETTERING ON RED BACKGROUND READING: "WARNING: PHOTOVOLTAIC POWER SOURCE". ·ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. ·ELECTRICAL EQUIPMENT THAT ARE IN OTHER THAN DWELLING UNITS SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF A POTENTIAL ARC FLASH. 110.16 ·NEC 690.13(B) EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON) POSITION AND BE PERMANENTLY MARKED “PV SYSTEM DISCONNECT” OR EQUIVALENT. ADDITIONAL MARKINGS SHALL BE PERMITTED BASED UPON THE SPECIFIC SYSTEM CONFIGURATION. FOR PV SYSTEM DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION, THE DEVICE SHALL BE MARKED WITH THE FOLLOWING WORDS OR EQUIVALENT: “TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION.” · THE RAPID SHUTDOWN INITIATION METHODS SHALL BE LABELED IN ACCORDANCE WITH 690.56(C). · 690.12 RAPID SHUTDOWN OF PV SYSTEMS ON BUILDINGS. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIfiC CONDUCTORS IN ACCORDANCE WITH 690.12(1) THROUGH (5) AS FOLLOWS. PV-4.1 825 E Clemensen Ave04/26/23 PV-4 PROJECT NO. DATEREVISION LICENSE NUMBER 749095 C-10 DATE: //2023 TI R I T I L L I , G E R A L D 82 5 C L E M E N S E N A V E . , SA N T A A N A , C A , 9 2 7 0 5 PH O N E : ( 7 1 4 ) 5 0 4 - 2 8 9 9 LE G A L D E S C R I P T I O N / A P N : 3 9 6 - 4 1 1 - 1 9 DRAWN BY: SOLAR PV ARRAY ON ROOF SERVICE POINT & UTILITY METERING BATTERY / PV DISCONNECT (NEXT TO MSP) BATTERY W/ INTEGRATED INVERTER,RAPID SHUTDOWN SWITCH FOR PV / ESS GATEWAY & MICRO-GRID SUB-PANEL (EXTERIOR WALL) ATTACH TO MAIN ELECTRIC SERVICE MIN. 3/8" LETTERING RED BACKGROUND WITH WHITE CHARACTERS NEC 705.10 & 690.56(B) 690.13(B) CAUTION: MULTIPLE SOURCES OF POWER ATTACH TO MAIN SERVICE PANEL WARNING ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ATTACH TO MAIN SERVICE PANEL REFLECTIVE LABEL RAPID SHUTDOWN FOR SOLAR PV SYSTEM ATTACH TO MAIN SERVICE PANEL MIN. 1/4" LETTERING RED BACKGROUND WITH WHITE CHARACTERS 690.54 PV POWER SOURCE OPERATING CURRENT: 40A OPERATING VOLTAGE: 240V ATTACH TO ANY INTERNAL AND EXTERIOR CONDUIT WITH SOLAR CIRCUIT 690.31(D)(2) WARNING: PHOTOVOLTAIC POWER SOURCE ATTACH TO INVERTER MIN. 1/4" LETTERING RED BACKGROUND WITH WHITE CHARACTERS 690.53 MAXIMUM DC VOLTAGE 600V OF PV SYSTEM NORTH DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM 705.10(C) ATTACH TO MAIN SERVICE PANEL WARNING: PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN 690.12 CEC 690.56(C) TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY. SOLAR ELECTRIC PV PANELS YOU ARE HERE RATED AC OUTPUT CURRENT: 40 AMPS NOMINAL OPERATING AC VOLTAGE: 240 VOLTS 825 E Clemensen Ave04/26/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 825 CLEMENSEN AVE., SANTA ANA, CA, 92705 STELLAR SOLAR 749095 FRIDA MOCK 760-603-8500 FRIDAM@STELLARSOLAR.NET 03/26/2023 825 E Clemensen Ave04/26/23 BREAKING THE 20 % EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9 %. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry: The new “Quality Controlled PV” of the independent certification institute TÜV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. 1 APT test conditions according to IEC / TS 62804-1:2015, method A (−1500 V, 96 h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings Q.PEAK DUO BLK ML-G10.a+ 385-405 ENDURING HIGH PERFORMANCE 825 E Clemensen Ave04/26/23 76.4 in 1940 mm 43.3 in 1100 mm 48.0 in 1220 mm 1656 lbs 751 kg 24 24 32 α [% / K]+0.04 β [% / K] −0.27 γ [% / K]−0.34 NMOT [°F] 109 ± 5.4 (43 ± 3 °C) Hanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us [V]1000 (IEC) / 1000 (UL) Class II [A DC]20 TYPE 2 [lbs/ft2] 75 (3600 Pa) / 55 (2660 Pa)−40 °F up to +185 °F (−40 °C up to +85 °C) [lbs/ft2] 113 (5400 Pa) / 84 (4000 Pa) 3 See Installation Manual 385 390 395 400 405 [W]385 390 395 400 405 [A]11.04 11.07 11.10 11.14 11.17 [V]45.19 45.23 45.27 45.30 45.34 [A]10.59 10.65 10.71 10.77 10.83 [V]36.36 36.62 36.88 37.13 37.39 [%]≥ 19.6 ≥ 19.9 ≥ 20.1 ≥ 20.4 ≥ 20.6 [W]288.8 292.6 296.3 300.1 303.8 [A]8.90 8.92 8.95 8.97 9.00 [V]42.62 42.65 42.69 42.72 42.76 [A]8.35 8.41 8.46 8.51 8.57 [V]34.59 34.81 35.03 35.25 35.46 53' 40' HC Certified UL 61730 MECHANICAL SPECIFICATION Format 74.0 in × 41.1 in × 1.26 in (including frame) (1879 mm × 1045 mm × 32 mm) Weight 48.5 lbs (22.0 kg) Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodized aluminum Cell 6 × 22 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98 in × 1.26-2.36 in × 0.59-0.71 in (53-101 mm × 32-60 mm × 15-18 mm), IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 49.2 in (1250 mm), (−) ≥ 49.2 in (1250 mm) Connector Stäubli MC4; IP68 Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Sp e c i f i c a t i o n s s u b j e c t t o t e c h n i c a l c h a n g e s © Q C E L L S Q. P E A K D U O B L K M L - G 1 0 . a + _ 3 8 5 - 4 0 5 _ 2 0 2 1 - 0 5 _ R e v 0 1 _ N A ELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W) Mi n i m u m Power at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP IMPP Voltage at MPP VMPP Efficiency1 η MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Mi n i m u m Power at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP IMPP Voltage at MPP VMPP 1Measurement tolerances P MPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power during first year. Thereafter max. 0.5 % degradation per year. At least 93.5 % of nominal power up to 10 years. At least 86 % of nominal power up to 25 years. All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m²) TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Nominal Module Operating Temperature PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS PV module classification Maximum Series Fuse Rating Fire Rating based on ANSI / UL 61730 Max. Design Load, Push / Pull3 Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull3 DETAIL A 0.63" (16 mm) 0.33" (8.5 mm)0.96" (24.5 mm) 42.8" (1088 mm) 74.0" (1879 mm) 4 × Mounting slots (DETAIL A) Frame 41.1" (1045 mm) 39.2" (996 mm) 1.26" (32 mm) 8 × Drainage holes 15.6 (395.5 mm) 4 × Grounding points ø 0.18" (4.5 mm) Label ≥49.2" (1250 mm) ≥49.2" (1250 mm) RE L A T I V E E F F I C I E N C Y CO M P A R E D T O N O M I N A L P OW E R [ % ] YEARS Q CELLS Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) 100 95 90 85 80 15 5 25200 10 98 86 200 400 600 800 1000 110 100 90 80 RE L A T I V E E F F I C I E N C Y [ % ] IRRADIANCE [W/m²] QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL 61730, CE-compliant, Quality Controlled PV - TÜV Rheinland, IEC 61215:2016, IEC 61730:2016, U.S. Patent No. 9,893,215 (solar cells), QCPV Certification ongoing. Horizontal packaging pallets pallets modules 825 E Clemensen Ave04/26/23 TESLA.COM/ENERGY POWERWALL+ Powerwall+ is an integrated solar battery system that stores energy from solar production. Powerwall+ has two separate inverters, one for battery and one for solar, that are optimized to work together. Its integrated design and streamlined installation allow for simple connection to any home, and improved surge power capability brings whole home backup in a smaller package. Smart system controls enable owners to customize system behavior to suit their renewable energy needs. KEY FEATURES • Integrated battery, inverter, and system controller for a more compact install • A suite of application modes, including self-powered, time-based control, and backup modes • Wi-Fi, Ethernet, and LTE connectivity with easy over-the-air updates NA 2022-05-06 825 E Clemensen Ave04/26/23 TESLA.COM/ENERGY POWERWALL+ COMPLIANCE INFORMATION PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1998 (US), IEEE 1547, IEEE 1547.1 Battery Energy Storage System Certifications UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL 1973, UL 9540, IEEE 1547, IEEE 1547.1, UN 38.3 Grid Connection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F)8 Recommended Temperature 0°C to 30°C (32°F to 86°F) Operating Humidity (RH)Up to 100%, condensing Storage Conditions –20°C to 30°C (–4°F to 86°F) Up to 95% RH, non-condensing State of Energy (SoE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type Type 3R Solar Assembly Ingress Rating IP55 (Wiring Compartment) Battery Assembly Ingress Rating IP56 (Wiring Compartment) IP67 (Battery & Power Electronics) Noise Level @ 1 m < 40 db(A) optimal, < 50 db(A) maximum MECHANICAL SPECIFICATIONS Dimensions 1596 x 755 x 160 mm (62.8 x 29.7 x 6.3 in) Total Weight 140 kg (310 lb)7 Battery Assembly 118 kg (261 lb) Solar Assembly 22 kg (49 lb) Mounting options Floor or wall mount 1Values provided for 25°C (77°F). 2Load start capability may vary. 3Where the DC input current exceeds an MPPT rating, jumpers can be used to allow a single MPPT to intake additional DC current up to 26 A Imp / 34 A Isc. 4Power factor rating at max real power. 5AC to battery to AC, at beginning of life. 6Cellular connectivity subject to network service coverage and signal strength. 7The total weight does not include the Powerwall+ bracket, which weighs an additional 9 kg (20 lb). 8Performance may be de-rated at operating temperatures below 10°C (50°F) or greater than 43°C (109°F). NA 2022-05-06 PHOTOVOLTAIC (PV) AND BATTERY ENERGY STORAGE SYSTEM (BESS) SPECIFICATIONS Powerwall+ Model Number 1850000-xx-y Solar Assembly Model Number 1538000-xx-y Nominal Battery Energy 13.5 kWh Nominal Grid Voltage (Input / Output) 120/240 VAC Grid Voltage Range 211.2 - 264 VAC Frequency 60 Hz Phase 240 VAC: 2W+N+GND Maximum Continuous Power On-Grid 7.6 kVA full sun / 5.8 kVA no sun1 Maximum Continuous Power Off-Grid 9.6 kW full sun / 7 kW no sun1 Peak Off-Grid Power (10 s) 22 kW full sun / 10 kW no sun1 Maximum Continuous Current On-Grid 32 A output Maximum Continuous Current Off-Grid 40 A output Load Start Capability 98 - 118 A LRA2 PV Maximum Input Voltage 600 VDC PV DC Input Voltage Range 60 - 550 VDC PV DC MPPT Voltage Range 60 - 480 VDC MPPTs 4 Input Connectors per MPPT 1-2-1-2 Maximum Current per MPPT (Imp) 13 A3 Maximum Short Circuit Current per MPPT (Isc) 17 A3 Allowable DC/AC Ratio 1.7 Overcurrent Protection Device 50 A breaker Maximum Supply Fault Current 10 kA Output Power Factor Rating +/– 0.9 to 14 Round Trip Efficiency 90%5 Solar Generation CEC Efficiency 97.5% at 208 V 98.0% at 240 V Customer Interface Tesla Mobile App Internet Connectivity Wi-Fi, Ethernet, Cellular LTE/4G)6 PV AC Metering Revenue grade (+/-0.5%) Protections Integrated arc fault circuit interrupter (AFCI), PV Rapid Shutdown Warranty 10 years 160 mm 1596 mm 755 mm 825 E Clemensen Ave04/26/23 TESLA.COM/ENERGY SOLAR SHUTDOWN DEVICE The Tesla Solar Shutdown Device is a Mid-Circuit Interrupter (MCI) and is part of the PV system rapid shutdown (RSD) function in accordance with Article 690 of the applicable NEC. When paired with Powerwall+, solar array shutdown is initiated by pushing the System Shutdown Switch if one is present. 650 mm 150 mm 125 mm 250 mm M4 Screw M8 Bolt Nail / Wood Screw 22 mm NA 2022-05-06 ENVIRONMENTAL SPECIFICATIONS Ambient Temperature -40°C to 50°C (-40°F to 122°F) Storage Temperature –30°C to 60°C (–22°F to 140°F) Enclosure Rating NEMA 4 / IP65 ELECTRICAL SPECIFICATIONS Model Number MCI-1 Nominal Input DC Current Rating (IMP) 12 A Maximum Input Short Circuit Current (ISC) 15 A Maximum System Voltage 600 V DC COMPLIANCE INFORMATION Certifications UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) RSD Initiation Method External System Shutdown Switch Compatible Equipment See Compatibility Table below MECHANICAL SPECIFICATIONS Electrical Connections MC4 Connector Housing Plastic Dimensions 125 mm x 150 mm x 22 mm (5 in x 6 in x 1 in) Weight 350 g (0.77 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw RSD MODULE PERFORMANCE Maximum Number of Devices per String 5 Control Power Line Excitation Passive State Normally open Maximum Power Consumption 7 W Warranty 25 years UL 3741 PV HAZARD CONTROL (AND PVRSA) COMPATIBILITY Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with the Powerwall+ and Solar Shutdown Devices. See the Powerwall+ Installation Manual for detailed instructions and for guidance on installing Powerwall+ and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Tesla Tesla TxxxS (where xxx = 405 to 450 W, increments of 5) 1 Solar Shutdown Device per 3 modules1 Tesla Tesla TxxxH (where xxx = 395 to 415 W, increments of 5) 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G6+1 Solar Shutdown Device per 3 modules 1Exception: Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to two modules between Solar Shutdown Devices. 825 E Clemensen Ave04/26/23 TESLA.COM/ENERGY SYSTEM LAYOUTS Powerwall+ with Backup Switch Installed Behind Utility Meter Powerwall+ with Backup Switch Installed Downstream of Utility Meter NA 2022-05-06 825 E Clemensen Ave04/26/23 TESLA.COM/ENERGY Powerwall+ with Backup Gateway 2 for Whole Home Backup Powerwall+ with Backup Gateway 2 for Partial Home Backup NA 2022-05-06 825 E Clemensen Ave04/26/23 Conformity Letter Number: MS-0009914, Attachment 1 Revision: 0 Effective date: 06/21/2019 Page 1 of 5 Tesla Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 USA Report Number: 32195439.001 Project Number: 234171546 and 234173937 Product(s) tested: Grid Support Utility Interactive Inverter with Gateway 2 or Backup Switch. Model(s): Powerwall+ (1850000-XX-Y) Dear Mr. /Mrs. Jonathan McCormick/Viraj Andrabadu/Nirja Vakil , Based on the evaluations undertaken, the model(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. Nationally Recognized Testing Laboratory (NRTL) TUV Rheinland of North America, Inc. NRTL Issuing Office Address 1279 Quarry Lane, Suite A, Pleasanton, CA 94566 Applicant Name Tesla, Inc. Applicant Address 3500 Deer Creek Road, Palo Alto, CA 94304, USA Model Numbers Powerwall+ (1850000-XX-Y) with Backup Switch ACPW (1092170-XX-Y, 2012170-XX-Y, 3012170-XX-Y) PVI (1538000-XX-Y) Backup Switch (1624171-XX-Y) Powerwall+ (1850000-XX-Y) with Gateway 2 ACPW (1092170-XX-Y, 2012170-XX-Y, 3012170-XX-Y) PVI (1538000-XX-Y) Gateway 2 (1232100-XX-Y) Software/Firmware Version 8586a41c49c Standard(s) Tested UL 1741: Standard for Inverters, Converters, Controllers and Interconnection System Equipment for Use with Distributed Energy Resources, April 20, 2010. Edition 2 [(Supplement SA)+R:15Feb2018], Power Control Systems (PCS), Certification Requirement Decision 3/8/2019 23rd June 2021 TUV Rheinland of North America, Inc. Pleasanton Office 1279 Quarry Lane, Suite A, Pleasanton, CA 94566 Tel: (925) 249-9123 Fax: (925) 249-9124 Web: www.us.tuv.com TUV Rheinland of North America, Inc. North American Headquarters 12 Commerce Road Newtown, CT 06470 Tel: +1 (203) 426- 0888 Fax: +1 (203) 426- 4009 Mail: info@tuv.com Web: www.tuv.com 825 E Clemensen Ave04/26/23 Conformity Letter Number: MS-0009914, Attachment 1 Revision: 0 Effective date: 06/21/2019 Page 2 of 5 PCS limits defined by NFPA 2020 edition section 705.13 Compliant and tested on 22nd June 2021 Testing period:04/21/21 – 05/07/21, 06/22/21 Reference reports: This document should be read together with 32195440.001 and 32195440.002 Powerwall+ ratings Nominal Battery Energy 13.5 kWh Nominal Grid Voltage 240 VAC Voltage range 211.2-264 VAC Maximum continuous Power On Grid 5 kW input/ 7.6 kW output BESS Continuous Power 5 kW input/ 5 kW output Maximum continuous Power Off Grid 5 kW input/ 9.6kW output Frequency 60 Hz Phase 240 VAC: 2 wire + neutral + ground Maximum continuous Power On Grid 32 A output BESS Continuous Power 24 A input Maximum continuous Power Off Grid 40 A output PV Maximum Input Voltage 600 VDC PV Operating DC Input Voltage range 60-550 VDC PV DC MPPT Voltage range 60-480 VDC Maximum Current per MPPT 13 A Maximum Short Circuit Current per MPPT 15 A Overcurrent Protection Device 50 A Software/Firmware version 8586a41c49c Enclosure Type Type 3R Rated ambient temperature [°C]-20°C to +50°C PCS ratings Maximum PCS controlled current 200 A Maximum Open Loop response time 9.09 seconds Average Open Loop response time 5.01 seconds 825 E Clemensen Ave04/26/23 Conformity Letter Number: MS-0009914, Attachment 1 Revision: 0 Effective date: 06/21/2019 Page 3 of 5 Attachments: 1. System Label for PCS 825 E Clemensen Ave04/26/23 Conformity Letter Number: MS-0009914, Attachment 1 Revision: 0 Effective date: 06/21/2019 Page 4 of 5 Thank you for the opportunity to service your product testing needs. Please do not hesitate to contact our engineering or sales team for any questions you may h ave. Evaluated by: Reviewed by: Himanshu Vaidya Howard Liu Test Engineer Manager, Power Electronics Segment – Americas Email: hvaidya@us.tuv.com Email: hliu@us.tuv.com 825 E Clemensen Ave04/26/23 Conformity Letter Number: MS-0009914, Attachment 1 Revision: 0 Effective date: 06/21/2019 Page 5 of 5 Revision History 6/22/21 – Himanshu Vaidya - Added project number 234173937 – project to test and evaluate Overcurrent limitation feature as per UL 1741 PCS standard Clause 208.1, A with respect to NFPA 70 2020 edition section 705.13. -Added testing period date 6/22/21 -Added row in Description table for above feature mentioned. 825 E Clemensen Ave04/26/23 Figure 2: Powerwall 2 Identification by Mounting Bracket Height • • 825 E Clemensen Ave04/26/23 • • • • • • • • • • • • • • • • • • 825 E Clemensen Ave04/26/23 Figure 3: Mounting Bracket Dimensions Figure 4: Location of Back Cable Entry Port in Relation to Bracket 825 E Clemensen Ave04/26/23 825 E Clemensen Ave04/26/23 : Figure 5: Mounting Powerwall on the Bracket 825 E Clemensen Ave04/26/23 • • 825 E Clemensen Ave04/26/23 • • • 825 E Clemensen Ave04/26/23 • • 825 E Clemensen Ave04/26/23 Figure 10: Meter Communication Port Connection on Top of Meter 825 E Clemensen Ave04/26/23 Figure 18: Powerwall 2 Mounting Bracket Dimensions and Space Requirements 825 E Clemensen Ave04/26/23 825 E Clemensen Ave04/26/23 825 E Clemensen Ave04/26/23 Backup Gateway 2 POWERWALL 380 mm (15 in) 127 mm (5 in) 584 mm (23 in) Backup Gateway 2 for Tesla Powerwall provides energy management and monitoring for solar self-consumption, time-based control, and backup operation. When the Powerwall system is in Backup mode, Backup Gateway 2 controls connection to the grid, automatically detecting outages and providing seamless transition to backup power. Communicating directly with Powerwall, Backup Gateway 2 allows you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Ingress Rating IP55 MECHANICAL SPECIFICATIONS Dimensions 584 mm x 380 mm x 127 mm (23 in x 15 in x 5 in) Weight 11.4 kg (25.1 lb) Breaker space (DIN rail)Main breaker: 1-, 2- or 3-pole Generation/Load breakers: 6 spaces Mounting options Wall mount PERFORMANCE SPECIFICATIONS AC Voltage (Nominal)240 V (Line-to-Neutral) 440 V (Line-to-Line) Feed-In Type Single Phase, Three Phase Grid Frequency 50/60 Hz Nominal Current 100 A per phase (Single Phase) 80 A per phase (Three Phase) Maximum Input Short Circuit Current 1 6 kA1 Overvoltage Category Category III AC Meter Revenue accurate (+/– 0.2 %) Connectivity Ethernet, Wi-Fi, Cellular (LTE/4G)2 User Interface Tesla App or Local Network Monitoring Operating Modes Support for solar self-consumption, time-based control, and backup Backup Operation Backup of selected single phase; Automatic disconnect of all phases Modularity Supports up to 10 AC-coupled Powerwalls Warranty 10 years IEC-62109-1, IEC 62053-22, IEC 61439-1, IEC 61439-3 EMC and Radio Equipment EMC Directive 2014/30/EU, Radio Equipment Directive 2014/53/EU, IEC 61000-6-1, IEC 61000-6-3, EN 55024, EN 300 328, EN 300 440, EN 301 489-1, EN 301 489-17, EN 301 489-52, EN 301 511, EN 301 893, EN 301 908-1 Environmental RoHS Directive 2011/65/EU, WEEE Directive 2012/19/EU, Battery Directive 2006/66/EC REACH Regulation EC 1907/2006 Seismic AC156, IEEE 693-2005 (high) 1 16 kA rating when installed with DIN-mount fuse; 10 kA rating without fuse. 2Cellular connectivity subject to network operator service coverage and signal strength (2G/3G supported where LTE/4G unavailable). COMPLIANCE INFORMATION ROW-UK 2019-02-21 TESLA.COM/ENERGY Safety 825 E Clemensen Ave04/26/23 INSTALLATION GUIDE 825 E Clemensen Ave04/26/23 INSTALLATION GUIDE 825 E Clemensen Ave04/26/23 INSTALLATION GUIDE 825 E Clemensen Ave04/26/23 INSTALLATION GUIDE 825 E Clemensen Ave04/26/23 INSTALLATION GUIDE 825 E Clemensen Ave04/26/23 INSTALLATION GUIDE 825 E Clemensen Ave04/26/23 INSTALLATION GUIDE 825 E Clemensen Ave04/26/23 INSTALLATION GUIDE 825 E Clemensen Ave04/26/23 INSTALLATION GUIDE 825 E Clemensen Ave04/26/23 VERSION: v2.5REVISION DATE: 07/6/21 INSTALLATION GUIDEINSTALLATIONGU RA T I N G S PAGE 06 TORQUE SPECIFICATIONS &ODVV$6\VWHPȴUHUDWLQJZLWK7\SH 39PRGXOHV$Q\PRGXOHWRURRIJDSLVSHUPLWWHGZLWKQRVNLUWUHTXLUHG7KLVUDWLQJLV applicable with any roof attachment. Fire Rating*Class A System Fire Rating Max System Voltage 9'& Max Fuse Rating 30A &HUWLȴFDWLRQ Conforms to UL STD 2703 Warranty <HDU0DWHULDODQG:RUNPDQVKLS UL 2703 Markings Product listing label is located on the rail end-caps 5RRI3LWFK Ȃ UL 2703 Allowable Design Load Rating SVIGRZQZDUGSVIXSZDUGDQGSVIODWHUDO Max Module Size VTIW Module Orientation Portrait or Landscape Multiple use Rated Components (Position Independent) Mid Clamp, Frame MLPE Mount and MLPE Mount UL 2703 MARKING EXAMPLE: Component Torque (in-lb)Notes /DJ6FUHZ N/A Fully Seat. Use visual indicator of the black EPDM ring around the bonded washer for torquing. Mid-Clamp End-Clamp 5DLO&OLFNHU/HYHOLQJ%ROW Pre-torqued upon delivery. Applies to Tile Hook and L-Foot/Clicker +RRN+HLJKW%ROW N/A /LJKWO\FODPSKRRNWRȵXVKZLWKWRSRIQH[WWLOHURZ Ground Lug N/A 5HIHUWRVSHFLȴFJURXQGOXJPDQXIDFWXUHUȇVLQVWDOODWLRQPDQXDO MLPE Clip MLPE Mount '0-'/*-8 7=78)1 0)*Ζ' &2'( 66644<<<< &RQIRUPVWR8/67' ;;;;;;; 70 RATINGS &ODVV$6\VWHPȴUHUDWLQJZLWK7\SH 39PRGXOHV$Q\PRGXOHWRURRIJDSLVSHUPLWWHGZLWKQRVNLUWUHTXLUHG7KLVUDWLQJLV\ J \S applicable with any roof attachment. Fire Rating*Class A System Fire Rating 825 E Clemensen Ave04/26/23 Composition Shingle, Tile, Metal Rail-Based Structural-Attach Direct-Attach ClickFit is one of the fastest installing rail-based systems in the industry. Thanks to its Click-In rail assembly, the rails can be connected to any of EcoFasten’s composition shingle, tile, and metal roof mounts in seconds without the need for fasteners or tools. The ClickFit system is made of robust materials such as aluminum and coated steel, to ensure corrosion-resistance and longevity. ClickFit conforms to UL 2703 and has been tested in extreme weather conditions including wind, fire, and snow. FEATURES & BENEFITS • Tool-less, fastener-free rail attachment • Fully integrated bonding • Click-On Mid & End Clamps • Compatible with a variety of EcoFasten roof attachments COMPLETE RAIL-BASED RACKING SYSTEM FAST INSTALLING SYSTEM FEATURING CLICK-IN RAIL ASSEMBLY ECOFASTENSOLAR.COM 825 E Clemensen Ave04/26/23 END CLAMP Click-on end clamp fits modules 30-50mm in width. MLPE MOUNT Attach Module Level Power Electronics to the top of the rail. END CAP The slide-on end caps allow the end clamps to be accurately positioned on the rail in seconds, while providing an aesthetically- pleasing, finished install. MID CLAMP Click-on mid clamp features integrated bonding pins and fits modules 30-50 mm in width. L-FOOT The ClickFit rail simply clicks into our proprietary composition shingle & tile L-foot without the need to use fasteners or tools. INTERNAL SPLICE Tool-free bonded internal Splice installs in seconds. 825 E Clemensen Ave04/26/23 ECOFASTENSOLAR.COM GF-1 FLASHING & L-FOOT COMPOSITION SHINGLE Combine the versatile ClickFit L-Foot with the watertight GF-1 flashing for a fast installation on composition shingle roofs. SIMPLEBLOCK-U STANDING SEAM METAL ROOFS Combine the ClickFit L-Foot with SimpleBlock®-U for a fast installation on standing seam metal roofs. CLICKFIT TILE HOOK TILE ROOFS Use the adjustable ClickFit Tile Hook for attaching the ClickFit system to tile roofs. Works with Flat, S, and W tile profiles. 825 E Clemensen Ave04/26/23 PRODUCT IMAGE PART NUMBER PART DESCRIPTION BOX QUANTITY PALLET QUANTITY ASSEMBLED WITH (1) GF GROMMET AND INCLUDES (1) 5/16” EPDM BONDED WASHER GF1M-GAL-BLK-810 GF1 8X10” BLK GLV W/ 2” HL PLCMT 50 3200 GF1-GAL-BLK-812 GF1 8X12” GALVALUME BLK FLASHING 50 2600 ALL HARDWARE INCLUDED WITH L-FOOT 1500004 CF L-FOOT ASSY (NO HARDWARE NEEDED)100 5000 1500005 CF TILE HOOK US 20 480 1510045 CF TILE HOOK SUB-FLASHING 20 2160 TILE HOOK FLSH-F ST TILE HOOK FLASH FLAT SIERRA TAN 12 576 TILE HOOK FLSH-W ST TILE HOOK FLASH W SIERRA TAN 12 576 TILE HOOK FLSH-S ST TILE HOOK FLASH S SIERRA TAN 12 576 INCLUDES (2) SS SET SCREWS OP 3/8”-24X7/8”, (1) SS HEX TAP BOLT 5/16”-18X1/2” AND (1) SS HEX NUT 5/16”-18 SIMPLEBLOCK-U-AL 2” SIMPLEBLOCK SSR-AL 25 4400 ALL HARDWARE INCLUDED WITH L-FOOT 1500004 CF L-FOOT ASSY (NO HARDWARE NEEDED)50 5000 1500033 CF RAIL 2130MM (~7 FT)N/A 108 1500034 CF RAIL 3166MM (~10.4 FT)N/A 108 1500035 CF RAIL 4202MM (~13.8 FT)N/A 108 1008061 CF RAIL SPLICE 100 3200 1510070 CF WIRE MGMT CLIP 1000 TBD 1500028 MODULE JUMPER, 8 IN (204MM)25 25000 1510057 CF MLPE MOUNT 400 17600 CO M P O S I T I O N R O O F S TI L E R O O F S ME T A L R O O F S RA I L S BO N D I N G 825 E Clemensen Ave04/26/23 PRODUCT IMAGE PART NUMBER PART DESCRIPTION BOX QUANTITY PALLET QUANTITY 1510041 CF ENDCAP, BLK LABELED 100 4800 1510015 CF HD ENDCLAMP 30MM, BLK 20 5600 1510016 CF HD ENDCLAMP 32MM, BLK 50 5600 1510017 CF HD ENDCLAMP 35MM, BLK 50 5600 1510018 CF HD ENDCLAMP 38MM, BLK 50 5600 1510019 CF HD ENDCLAMP 40MM, BLK 50 5600 1510020 CF HD ENDCLAMP 45MM, BLK 50 5600 1510011 CF HD MIDCLAMP 30-40MM, BLK 50 5600 1510012 CF HD MIDCLAMP 40-50MM, BLK 50 5600 INCLUDES (1) END CAP AND (2) MID CLAMP CAPS ROCK-IT V3 SKIRT A65 ROCK-IT SKIRT V3 35MM & 40MM 65”8 256 ROCK-IT V3 SKIRT A79 ROCK-IT SKIRT V3 35MM & 40MM 79”8 256 ROCK-IT V3 SKIRT A80 ROCK-IT SKIRT V3 35MM & 40MM 80”8 256 ROCK-IT V3 SKIRT B65 ROCK-IT SKIRT V3 32MM & 38MM 65”8 256 ROCK-IT V3 SKIRT B79 ROCK-IT SKIRT V3 32MM & 38MM 79”8 256 ROCK-IT V3 SKIRT B80 ROCK-IT SKIRT V3 32MM & 38MM 80 8 256 ASSEMBLED WITH (1) SS 5/16-18X2.5 FLANGE BOLT AND (1) 5/16 ANTI-LOSS WASHER 1500003 CF UNIVERSAL SKIRT CLAMP BLK 50 5750 POLY KIT LAG SCREW 4 POLY KIT LAG SCREW 4” (50)50 480 SCRW DP 15-13X03 ROOFING SCRW #15 X 3” DRILL PT 1000 60000 INCLUDES (1) 2” LAG BOLT AND (1) SS 8-18 X 3/4” TEK SCREW 1510001 CONDUITMOUNT-BRKT 50 10350 INCLUDES (1) SS 8-18 X 3/4” TEK SCREW CONDUITMOUNT-TILE CONDUIT MOUNT-TILE SYSTEM 60 4320 CL A M P S SK I R T S FA S T E N E R S AC C E S S O R I E S 825 E Clemensen Ave04/26/23 4 14 1 W. VAN BUREN ST, SUITE 2, PHOENIX AZ 85009 1 - 87 7 - 85 9- 3 947 | I NFO @E C O FA ST E NSO LA R. C O M ECOFASTEN SOLAR EcoFasten has an established a reputation for being one of the industry’s leading innovators by providing expert solutions for mounting solar PV on any type of roof. Our broad portfolio of solutions stem from the needs of, and direct inputs by solar PV installers. We take pride in providing the right solution for every application. We educate our customers, so they purchase the best, most cost-effective solutions to fit their needs, and we complement that with on- site installation training to ensure 100% satisfaction. We are honest with ourselves, our customers, and our employees, fostering a culture of idea-sharing, innovation, and creativity. VE R S I O N 1 . 2 825 E Clemensen Ave04/26/23 STRUCTURAL CALCULATIONS FOR GERALD TIRITILLI 825 CLEMENSEN AVE SANTA ANA CA 92705 ENGINEER: BWU Consultants, Inc 1168 San Gabriel Blvd #N Rosemead, CA 91770 825 E Clemensen Ave04/26/23 DESIGN DATA 1. CODE: 2022 CALIFORNIA BUILDING CODE ASCE 7-16 2. MATERIAL STRENGTH CONCRETE: Fc’ = 2,500 PSI @ 28 DAYS CONCRETE REBAR: ASTM A615 GRADE 40 Fy = 40,000 PSI STEEL: (AISC 360) 13 EDITION STRUCTURAL SHAPES: ASTM A36 Fy = 36 KSI TUBING: STM A500 GRADE B Fy = 46 KSI PIPE: ASTM A53 TYPE E GRADE B Fy = 35 KSI WOOD: DOUGLAS FIR-LARCH ( 19% MAX. M.C. ) JOIST & RAFTER #2 GRADE Fb = 875 PSI Fv = 95 PSI E = 1.6 x 1,000,000 BEAM & HEADER (4X) #1 GRADE Fb = 1,000 PSI Fv = 95 PSI E = 1.7 x 1,000,000 (6X) #1 GRADE Fb = 1,000 PSI Fv = 85 PSI E = 1.7 x 1,000,000 POST (4X) #1 GRADE Fb = 1,000 PSI Fv = 95 PSI E = 1.6 x 1,000,000 (6X) #1 GRADE Fb = 1,000 PSI Fv = 85 PSI E = 1.7 x 1,000,000 STUD #2 GRADE Fb = 675 PSI Fv = 95 PSI E = 1.4 x 1,000,000 SELECT STRUCTURAL (6x, LARGE) Fb = 1,450PSI Fv = 95 PSI E = 1.9 x 1,000,000 MASONRY: CONCRETE BLOCK ASTM C90 Fm = 1500 PSI NO INSPECTION REQUIRED 3. SOIL REPORT: f’s= 1,500 PSF/ OR SEE SOILS REPORT 4. LATERAL ANALYSIS: A. SEISMIC LOAD W CV SSEE ATTACHED. B. WIND LOAD (SIMPLIFIED PROCEDURE) (130 mph) EXP “C” ULTIMATE 825 E Clemensen Ave04/26/23 825 E Clemensen Ave04/26/23 BWU Consultants, Inc. 1168 N. San Gabriel Blvd., #N Rosemead, CA. 91770 Tel: (626) 288-0708 Email: twengrs1168@gmail.com Date: D.L.SIZE: SHINGLE ROOF'G 4 psf 18.0 SQ.FT. 1/2" PLYWD SHT'G 1.5 2x8 @ 24 O.C.1.5 RAFTER MISC 0 WEIGHT: D.L. = WT = 2.9#/SQ.FT. L.L. = (USE 3.0 #/SQ.FT.) T.L. = L:7'-0" MAX SPAN W:60.0 plf M:367.5 pf Sreq: 2.92 in³ R:210 lb Areq: 2.65 in² 2x8 RAFTER CAN CARRY SOLAR PANELS GRAVITY PER 2022 CALIFORNIA EXISTING BLDG CODE. PART 10. SECTION 502.4 & 503.3 9 x 3 x 18 =486 lb 32700 lb 486 / 32700 =1.5% (ROOF DL 7 + CL'G DL 5 + PART'N 16/2) x 1635 = (7+3+20) x 24/12 = (2022 CALIFORNIA BUILDING CODE) ASCE 7-16 EXIST'G ROOF LOAD'G (AS BUILT) SOLAR PANEL 30.0 psf 20.0 psf 7.0 psf 825 E Clemensen Ave04/26/23 WIND LOAD (RISK CATEGORY III,IV) 130 MPH, EXP ”C” CHAP 26.10.2 - WIND LOAD COMPONENTS & CLADDING (C&C) qz= .00256 Kz Kzt Kd V2 I (26-10-1) Ht. z at the centroid of area Af = 10 ft Exp = Exposure coefficient Kz = 0.85 c (TABLE 26.8-1) Topography factor Kzt = 1.00 (FIGURE 26.8-1) Directionality factor Kd = 0.85 Wind Speed V = 130 mph Importance factor Iw = 1.00 qz = 0.00256 x 0.85 x 1.0 x 0.85 x (130)2 = 31.26 psf Gust Effect factor G = 0.85 Force coeff Cf = 1.31 Design wind pressure, F/Af = 31.26 x 0.85 x 1.31 = 34.81 psf ASCE 7-16 825 E Clemensen Ave04/26/23 BWU Consultants, Inc. 1168 N. San Gabriel Blvd., #N Rosemead, CA. 91770 Tel: (626) 288-0708 Email: twengrs1168@gmail.com Date: UPLIFT / WITHDRAWAL FORCE FOR SOLAR PANEL STANDOFF / FAST JACK Vup= 34.81 lb/sq.ft SEISMIC PER 2022 CALIFORNIA EXISTING BLDG CODE. PART 10. SECTION 502.5 & 503.4 486 lb / 32700 lb = 1.5% < 10.0% OK Vall = 274 x 2.5 = 685 lb > 256.3 lb OK 9 9 x 34.81 x 18 = 5639.22 lb 22 256.3 lb/lag screw NO. SOLAR PANELS UPLIFT FORCE SUPPORTS OF TILE HOOK/STANDOFF UNIT FORCE PER (5/16"ø) LAG SCREW O.K. USE 5/16"ø X 3 1/2" LONG STAINLESS STEEL LAG SCREW WITH MIN. 2 1/2" EMBED TO EXIST'G ROOF MEMBER. CAN RESIST WIND UPLIFT FORCE. LATERAL (2022 CALIFORNIA BUILDING CODE) WIND EXP "C", WIND SPEED: 130 mph (ASCE 7-16) 825 E Clemensen Ave04/26/23 825 E Clemensen Ave04/26/23 T-1 PROJECT NO. DATEREVISION LICENSE NUMBER 749095 C-10 DATE: //2023 TI R I T I L L I , G E R A L D 82 5 C L E M E N S E N A V E . , SA N T A A N A , C A , 9 2 7 0 5 PH O N E : ( 7 1 4 ) 5 0 4 - 2 8 9 9 LE G A L D E S C R I P T I O N / A P N : 3 9 6 - 4 1 1 - 1 9 DRAWN BY: PROJECT SCOPE:TABLE OF CONTENT: TIRITILLI, GERALD 825 CLEMENSEN AVE., SANTA ANA, CA, 92705 GENERAL NOTES: VICINITY MAP: GENERAL NOTES: · SOLAR PHOTOVOLTAIC & BATTERY SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. · DESIGN COMPLYING WITH THE 2022 EDITION OF CALIFORNIA ELECTRICAL CODE, NEC, 2022 CALIFORNIA BUILDING CODE, 2022 CALIFORNIA RESIDENTIAL CODE, CITY OF SANTA ANA CONSOLIDATED FIRE CODE, AND ALL LOCAL ORDINANCES AND POLICIES. · THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITHSTAND A MINIMUM 110 MPH WIND LOAD. ·THIS HOUSE IS 1 STORY TALL. ·THE RAFTER ARE 2" X 8" AND 24" ON CENTER. ·THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. ·THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH STORAGE BATTERIES. ·THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. ·IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. ·A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL-OSHA REGULATIONS. ·PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED AS PER SECTION 110.26 CEC. ·WHERE A UFER CANNOT BE VERIFIED OR IS NOT PRESENT, A GROUNDING ELECTRODE SYSTEM SHALL BE INSTALLED AS PER CEC 250.53. ·ROOF MOUNTED CONDUIT AND RACEWAYS SHALL BE 7/8TH'S OFF THE ROOF DECK OF THE STIPULATIONS OF 310.15(B)(3)(C) SHALL APPLY. ·NO GROUND DISTURBANCE WILL OCCUR SHEET #DESCRIPTION T-1 TITLE SHEET PV-1 SITE MAP PV-2 ARRAY LAYOUT PV-2.1 PANEL SCHEDULE PV-3 ELECTRICAL LINE DIAGRAM PV-4 SIGNAGE PV-4.1 SIGNAGE / ELECTRICAL NOTE RIDGE SETBACKS - <33% TOTAL ROOF AREA 2022 CA INTERVENING CODE R324.6.1 & R324.6.2 : · R324.6.1 NOT LESS THAN TWO MINIMUM 36 IN. WIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM THE LOWEST ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDING. AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. · R324.4.6.2 SETBACK AT RIDGE. FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 PERCENT OF THE PLAN VIEW TOTOAL ROOF AREA, NOT LESS THAN 18 INCHES CLEAR SETBACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. NOTE: TOTAL ROOF AREA - 1635 SQ FT. SOLAR ARRAY AREA - 190 SQ FT. 190 / 1635 = .11 .11 X 100 = 11.00 % 11% < 33% SCOPE OF WORK: · (9) HANWHA Q.PEAK DUO BLK ML-G10 405 MODULES · (1) TESLA POWERWALL+ "PLUS" BATTERY / INVERTER · (1) 200A TESLA GATEWAY 2 · (1) 200A MICROGRID SUBPANEL · (3) MID CIRCUIT INTERRUPTERS (MCI's) · (1) RAPID SHUTDOWN DEVICE · (1) BATTERY / INVERTER DISCONNECT · 3.65 KW DC / 3.33 KW CEC AC SYSTEM SIZE 825 CLEMENSEN AVE., SANTA ANA, CA, 92705 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101114728 Elec# 20179360 Issued 04/25/23 825 E Clemensen Ave04/26/23