HomeMy WebLinkAbout800 W Santa Ana Blvd - PlanALIGN ADJACENT FINISH SURFACES CENTERLINE DESIGNATION FINISH CODE - REF. LEGEND THIS SHEETP1 CARPET C1 - TO BE DETERMINED BASE B1 - TO BE DETERMINED QUARTZ Q1 - TO BE DETERMINED PLASTIC LAMINATE PL1 - WILSONART HIGH PRESSURE LAMINATE; COLOR: FAWN CYPRESS #8208K-16 PL2 - WILSONART HIGH PRESSURE LAMINATE; COLOR: WHITE PAINT P1 - FIELD; TO BE DETERMINED P2 - ACCENT; TO BE DETERMINED WOOD STAIN ST1 - TO BE DETERMINED CEILING TILES CT1 - TO MATCH (E) PL1 Q1 B1 B A10.1 2' - 1 0 " P1 PL1 PL2 TYP. B A10.1 D A10.1 Q1 PL1 Q1 PL1 PL1 Q1 C A10.1 F A6.1 B1B1 Q1 PL2 PL2 B1 REMOVABLE WIRING ACCESS PANEL QUARTZ COUNTER TOP 4" 2' - 0 " 4" 1' - 11 1/2"10" 3' - 3" 2' - 1 0 " 4"4" 1' - 4 " O P E N I N G OPEN CHASE 1/4" RADIUS, TYP. OF ALL EDGES 3/4" PLYWOOD ov/ 2x6 D.F. STUDS, EA. SIDE B1 PL1 B1 PL1 Q1 RUBBER BASE RUBBER BASE TELLERS BRANCH 2 1/2" DIA. STAINLESS STEEL GROMMET - REF. NOTATION PLAN FOR LOCATIONS FINISH FLOOR PL1 REMOVABLE WIRING ACCESS PANEL QUARTZ COUNTER TOP 4" 2' - 3 " 4" 3' - 5 " 4" 1' - 7 " O P E N I N G OPEN CHASE 1/4" RADIUS, TYP. OF ALL EXPOSED QUARTZ EDGES 3/4" PLYWOOD ov/ 2x6 D.F. STUDS, EA. SIDE B1 PL1 B1 PL1 Q1 RUBBER BASE RUBBER BASE TELLERS BRANCH 2 1/2" DIA. STAINLESS STEEL GROMMET - REF. NOTATION PLAN FOR LOCATIONS FINISH FLOOR 3' - 1 1 " 4" 2" 4" EQ EQ 1' - 11 1/2"9 1/2" PL1 Q1 PL1 PL1 PL1 Q1 B1 P1 PL1 Q1 PL1 PL1PL1PL1 PL1 PL1 B1 B1 PL1PL1 1' - 3" B1 1' - 3" 1" OVERHANG 1" OVERHANG 1" OVERHANG 05.02 05.02 PL1 PL1 PL1 PL1 Q1 Q1 Q1 B1 B1 B1 QUARTZ COUNTER TOP 3' - 5 " 4" OPEN CHASE 1/4" RADIUS, TYP. OF ALL EXPOSED QUARTZ EDGES 3/4" PLYWOOD ov/ 2x6 D.F. STUDS, EA. SIDE PL1 Q1 TELLERS BRANCH 3' - 1 1 " 4" 2" 4" EQ EQ 1' - 11 1/2" 9 1/2" Q1 PL1 2x6 BLOCKING w/ #14 x 2-1/2" WD. SCREWS @ 8" O.C. (TYP.) , PLUS ONE #14 SCREW @ EA. CORNER - TYP. @ ALL CORNERS 1 3/4" LEG STAPLE @ 8" O.C. 2x OR 3/4" PLYWOOD #14 x 3-1/2" FLAT HEAD WD. SCREWS AT 16" O.C. CONT 2x4 w/ 1/4" WEDGE ANCHORS @ 24" O.C. DRAWER BASE CABINET ADJUSTABLE SHELVES -TYP. 3" 4" 1' - 10" QUARTZ COUNTER TOP 4"4" 4' - 7 " 1/4" RADIUS, TYP. OF ALL EXPOSED QUARTZ EDGES 3/4" PLYWOOD ov/ 2x6 D.F. STUDS, EA. SIDE B1 PL2 B1 Q1 RUBBER BASE RUBBER BASE TELLERS BRANCH FINISH FLOOR PL1 PL1 4" 4" 2' - 5 1/2" 4" 3' - 3" PRODUCT & MATERIAL REQUIREMENTS FOR INDOOR POLLUTANT CONTROL 1. ALL MATERIALS, ADHESIVES, COATINGS, AND SEALANTS SHALL COMPLY WITH V.O.C. LIMITATIONS SET FORTH BY THE LOCAL AIR POLLUTION CONTROL DISTRICT OR CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 11 (CALGREEN BUILDING STANDARDS), WHICHEVER IS MORE RESTRICTIVE. 2. ALL CARPET MATERIALS SHALL MEET THE TESTING AND PRODUCT REQUIREMENTS OF THE CARPET & RUG INSTITUTE’S GREEN LABEL PLUS PROGRAM OR EQUIVALENT CRITERIA SET FORTH IN CALIFORNIA CALGREEN BUILDING STANDARDS. 3. A MINIMUM OF 50% OF RESILIENT FLOORING SHALL COMPLY WITH THE V.O.C. EMISSION LIMITS DEFINED IN 2009 COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CHPS) CRITERIA AND LISTED ON ITS LOW-EMITTING MATERIALS LIST OR CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE FLOORSCORE PROGRAM. 4. ALL HARDWOOD COMPOSITE WOOD PRODUCTS (PLYWOOD, PARTICLEBOARD, AND MEDIUM DENSITY FIBERBOARD) SHALL MEET THE MAXIMUM FORMALDEHYDE EMISSIONS LIMITATIONS AS SPECIFIED IN ARB’S AIR TOXIC CONTROL MEASURE FOR COMPOSITE WOOD (17 CCR 93120 ET SEQ.) BY THE DATES SPECIFIED IN THOSE SECTIONS. 5. ARCHITECT HAS MADE EVERY REASONABLE ATTEMPT TO CONFIRM THAT PRODUCTS SPECIFIED IN THESE DOCUMENTS COMPLY WITH ABOVE-LISTED REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE SUBCONTRACTOR, VENDOR, AND/OR MANUFACTURER TO NOTIFY THE ARCHITECT THROUGH THE GENERAL CONTRACTOR OF ANY NON -COMPLIANT PRODUCT OR MATERIAL SPECIFIED BY THE ARCHITECT PRIOR TO BID DUE DATE. 6. CONTRACTOR SHALL PROVIDE PRODUCT/MATERIAL COMPLIANCE DOCUMENTATION WITH SUBMITTAL DOCUMENTS AS REQUIRED BY SPECIFICATION SECTION 013323. CONTRACTOR SHALL SUBMIT COMPLIANCE DOCUMENTATION TO THE JURISDICTION HAVING AUTHORITY UPON ACCEPTANCE BY ARCHITECT. L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 4/6/2023 9:21:06 AM A10.1 CASEWORK ELEVATIONS + DETAILS 03.03.23 PERMIT SUBMITTAL 04.06.23 PLAN CHECK 011 Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 LEGEND FINISHES LEGEND 3/8" = 1'-0" 3 STANDING COUNTER FROM LOBBY 3/8" = 1'-0"1 ACCESSIBLE COUNTER FROM LOBBY 1 1/2" = 1'-0"C ACCESSIBLE TELLER COUNTER 1 1/2" = 1'-0"B STANDING TELLER COUNTER 3/8" = 1'-0"4 STANDING COUNTER FROM TELLERS 3/8" = 1'-0"2 ACCESSIBLE COUNTER FROM TELLERS 1 1/2" = 1'-0" A STANDING TELLER COUNTER w/ CABINET 1 1/2" = 1'-0"D TELLER COUNTER @ TCR KEYNOTES 05.02 CASH DRAWER TO BE OWNER PROVIDED, CONTRACTOR INSTALLED NO. NAME FLOOR BASE WALL CEILING COMMENTS 100 OPEN OFFICE C1 B1 P1 CT1 101 BRANCH C1 B1 P1 CT1 102 OFFICE C1 B1 P1 CT1 103 TELLERS C1 B1 P1 / PL1 / PL2 CT1 ROOM FINISH SCHEDULE 800 W Santa Ana Blvd. - 10111445404/06/23 ACCESSIBLE PEDESTRIAN ROUTE: MIN. WIDTH = 48" MAX. SURFACE SLOPES: CROSS SLOPE = 1:48" MAX. SLOPE IN DIRECTION OF TRAVEL = 1:20 MAX. RUNNING SLOPE ON RAMPS AND CURB RAMPS = 1:12 MAX. NO VERTICAL OFFSETS IN EXCESS OF 1/4" W E S T S A N T A A N A B O U L E V A R D W E S T 3 R D S T R E E T EXISTING BUILDING (AREA OF WORK) EXISTING ACCESSIBLE PARKING TO REMAIN L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 4/6/2023 9:21:03 AM A1.1 SITE PLAN 03.03.23 PERMIT SUBMITTAL 04.06.23 PLAN CHECK 011 Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 LEGEND 1/4" = 1'-0" SITE PLAN NOT TO SCALEPROJECT NORTH TRUE NORTH Bldg permit #101114454 - Bldg Approved by A. So on 4/6/23 Planning approved on 4/6/23 by F. Arias - No Insp. Req'd PW approved on 4/6/23 by B. Sarlak - No Insp. Req'd Elect permit #20179247 - No p/c req'd Permit issued on 4/6/23 800 W Santa Ana Blvd. - 10111445404/06/23 1 2 3 4 5 6 7 A B C AA OPEN OFFICE 100 VAULT 104 DATA 105 ELEC. 106 TOILET 108 JAN. 109 STOR. 110 KITCHEN 111 TRAINING 112 BOARD ROOM 113 OFFICE 114 CEO OFFICE 115 OFFICE 116 QUIET ROOM 117 OPEN OFFICE 118 TOILET 107 AL I G N MIN. 3' - 0" 1 1 ' - 9 " 1 4 ' - 1 0 " BRANCH 101 TELLERS 103 OFFICE 102 6' - 0 " 5' - 1 0 " 5 1 / 2 " COUNTERS SHOWN DASHED FOR CLARITY 8' - 3 1/2" 5' - 0 1/2" 2' - 1 1/2" 4' - 9" 2' - 3" 14' - 4" 1 1 2 3 4 5 6 7 A B C AA OPEN OFFICE 100 BRANCH 101 VAULT 104 DATA 105 ELEC. 106 JAN. 109 STOR. 110 KITCHEN 111 TRAINING 112 BOARD ROOM 113 OFFICE 114 CEO OFFICE 115 OFFICE 116 QUIET ROOM 117 101.2 OPEN OFFICE 118 1 1 1 4 TOILET 108 TOILET 107 06.01 06.01 06.01 06.01 06.01 06.01 06.01 103.2 102.1 103.1 101.1 100.1 101.3 1 1 1 TELLERS 103 OFFICE 102 1 5 3 1 6 5 53 3 6 05.01 5 4 7 2 2 05.01 +41"+41"+3 4 " 1 1 1 1. ALL DIMENSIONS ARE TO FACE OF STUD OR FACE OF EXISTING FINISH, U.O.N. 2. SCHEDULED DETAILS REFER TO DETAILS ON SHEET A6.1, U.O.N. 3. REFER TO SHEET FOR POSTED SIGNAGE 4. INTERIOR SHEAR PLY NOT INDICATED -COORDINATE LOCATIONS w/ STRUCTURAL DRAWINGS 5. PROVIDE MOISTURE-RESISTANT GYP. BD. AT ALL WET LOCATIONS AND/OR TO RECEIVE WALL TILE -REFER TO SHEET A10.1 6. FOR ALL EXISTING SURFACES DISTURBED BY THE NEW CONSTRUCTION: PATCH, REPAIR, AND REFINISH TO MATCH. UPON COMPLETION OF THE PROJECT, THERE SHALL BE NO VISUAL DIFFERENCE BETWEEN THE NEW WORK AND EXISTING CONDITIONS. 7. REFER TO DETAIL FOR CONC. SLAB REPAIR 8. PARALLEL WHEELCHAIR APPROACH @ COUNTER T3.1 G / A6.1 1 INTERIOR WALL TYPE - REF. SCHEDULE THIS SHEET 101.1 DOOR NUMBER -REF. A8.1 FOR SCHEDULE GLAZED FRAME NUMBER - REF. A8.1 FOR SCHEDULE CABINET ELEVATION - REF. A11.11 1 EXISTING WALL TO REMAIN NEW WALL - SEE C / A6.1 1 ALIGN ADJACENT FINISH SURFACES CENTERLINE DESIGNATION 1 L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 4/6/2023 10:04:21 AM A2.1 FLOOR PLANS 03.03.23 PERMIT SUBMITTAL 04.06.23 PLAN CHECK 011 Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 1/8" = 1'-0" DIMENSION PLAN 1/8" = 1'-0" NOTATION PLAN GENERAL NOTES NO. CORE INSUL. WALLBD. EXTENT DETAILS HEAD SILL 1 2x4 D.F. STUDS @ 16" O.C. ACOUST. F.G. BATT. 5/8" GYP. BD. BOTH SIDES CORE, INSUL. & WALLBD. TO 6" ABOVE FINISH CEILING D E 2 2x4 D.F. STUDS @ 16" O.C. - 3/4" PLYWOOD BOTH SIDES CORE & WALLBD. TO 2'-10" A.F.F. - F, SIM. 3 2x4 D.F. STUDS @ 16" O.C. - 3/4" PLYWOOD BOTH SIDES CORE & WALLBD. TO 4'-7" A.F.F. - F, SIM. 4 2x6 D.F. STUDS @ 16" O.C. - 5/8" GYP. BD. BOTH SIDES CORE & WALLBD. TO 6" ABOVE FINISH CEILING D, SIM. E, SIM. 5 2x6 D.F. STUDS @ 16" O.C. - 3/4" PLYWOOD BOTH SIDES CORE & WALLBD. TO 2'-10" A.F.F. C / A11.1 F 6 2x6 D.F. STUDS @ 16" O.C. - 3/4" PLYWOOD BOTH SIDES CORE & WALLBD. TO 3'-5" A.F.F. A & B / A11.1 F 7 2x6 D.F. STUDS @ 16" O.C. - 3/4" PLYWOOD BOTH SIDES CORE & WALLBD. TO 4'-7" A.F.F. D / A11.1 F KEYNOTES 05.01 2½" DIA. STAINLESS STEEL GROMMET 06.01 PATCH & REPAIR GYP. BD. AS REQ'D FROM DEMOLITION LEGEND INTERIOR WALL SCHEDULE 800 W Santa Ana Blvd. - 10111445404/06/23 4x6 BLOCKING -TOE NAIL w/ (4) 10d NAILS 2x WOOD STUDS FOR GRAB BARS / WALL HUNG LAVS / ITEMS NOT NOTED. MOUNT USING #14 SELF-TAPPING S.M.S. TYPE C FOR TOILET ACCESSORIES EXCLUDING GRAB BARS. MOUNT USING #10 WOOD SCREWS. TYPE A 2x WOOD STUDS 6" x 16 GA STEEL PLATE SECURE TO STUDS w/ (2) #10 x 1/2" S.M.S. LENGTH AS REQ'D TO SUPPORT ITEM 2x WOOD STUDS 2x6 BLOCKING - TOE NAIL w/ (4) 10d NAILS TYPE B FOR MED. GAS PANELS / BASE CABINETS / WALL GUARDS / WALL HUNG CABINETS / WALL HUNG EQUIP. MOUNT USING #12 WOOD SCREWS. STD. STUD SPAC I N G STD. STUD SPAC I N G STD. STUD SPAC ING LENGTH AS REQ'D TO SUPPORT ITEM LENGTH AS REQ'D TO SUPPORT ITEM SOUND ATTENUATION BATTS 5/8" GYPSUM BOARD 2x4 D.F. STUDS 5/8" GYPSUM BOARD 2x PRESSURE-TREATED SILL PLATE w/ POWDER-DRIVEN ANCHORS @ 32" O.C. (E) SLAB ON GRADE 2x4 D.F. ANGLED DIAGONAL BRACING @ 48" O.C. -ALTERNATE DIRECTION. DECK ATTACHMENT REFER TO TRACK w/ (2) #8 SCREWS @ EA. STUD 2x BLOCKING TYP. @ CEILING 6" M I N . 16 GA. x 1½" x 1½" x 3" LONG CLIP ANGLE w/ (2) #8 SCREWS EA. TO BRACE & TRACK WALL, PER SCHEDULE C A6.1 1' - 6" MAX. 4" EQ EQ EMBED 4" COMPACTED TRENCH MATERIALS COMPACTED SAND OR CLASS II AGGREGATE BASE (CONCRETE FILL OPTIONAL) SAWCUT (E) SLAB #4 DOWEL @ 24" O.C. EACH SIDE (N) 3000 PSI CONC. FILL CLEAN CUT SURFACE -APPLY CONC. BONDING AGENT - TYP. 4" FIRECAULK ALL CONDUIT PENETRATIONS 5/8" TYPE 'X' GYPSUM BOARD WALL, PER SCHEDULE 2x BLOCKING ALL AROUND 2x BLOCKING 2 1/2" SEMI-RECESSED FIRE EXTINGUISHER CABINET 4' -0" MAX. A.F.F. PROVIDE 2x4 BLKG. BETWEEN TRUSS AS REQUIRED 2x4 D.F. @ 48" O.C. ANGLE BRACING- ALTERNATE DIRECTION SUSPENDED ACOUSTICAL CEILING WALL, PER PLAN D A6.1 E A6.1 1 1 QUARTZ COUNTER TOP 3/4" PLYWOOD 1/4" RADIUS, TYP. 3/4" PLYWOOD EA. SIDE BASE 2x6 D.F. STUDS @ 16" O.C. 2x BLOCKING 4" VA R I E S - R E F . W A L L S C H E D U L E 11 1/2" PLASTIC LAMINATE EA. SIDE PL1 B1 Q1 2x PRESSURE-TREATED SILL PLATE w/ POWDER-DRIVEN ANCHORS @ 32" O.C. (E) SLAB ON GRADE L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 4/6/2023 9:21:04 AM A6.1 DETAILS 03.03.23 PERMIT SUBMITTAL 04.06.23 PLAN CHECK 011 Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 1/4" = 1'-0"A TYP. BACKING PLATES 3" = 1'-0" E WALL BASE 3" = 1'-0"D TOP OF WALL @ BRACING 1 1/2" = 1'-0" G CONC. SLAB REPAIR 3" = 1'-0"B TYP. FIRE EXTINGUISHER CABINET 1/2" = 1'-0"C WOOD STUD BRACES, NON-BEARING WALL 1 1/2" = 1'-0" F LOW WALL 800 W Santa Ana Blvd. - 10111445404/06/23 1. MAXIMUM VERTICAL OFFSET AT DOOR THRESHOLD SHALL BE 1/4" VERTICAL OR 1/2" IF BEVELED - REFER TO THRESHOLD DETAIL(S). 2. ALL DOORS THAT ARE PART OF THE MEANS OF EGRESS SHALL BE EQUIPPED WITH HARDWARE THAT OPENS THE DOOR FROM THE INTERIOR WITHOUT SPECIAL KNOWLEDGE, EFFORT, OR A KEY. 3. MAXIMUM DOOR OPENING EFFORT SHALL BE 5# AT NON-RATED DOORS AND 15# AT FIRE RATED DOORS. 4. SEE SPECIFICATIONS FOR DOOR HARDWARE SETS AND PRODUCTS. 5. ALL GLASS IN DOOR PANELS TO BE TEMPERED. 6. REFER TO SHEET A10.1 FOR FINISH CODE LEGEND 7. SCHEDULED DETAILS REFER TO DETAILS ON THIS SHEET U.O.N. 8. OPERATING HARDWARE FOR LOCKSETS/LATCHSETS SHALL BE LEVER TYPE: FACE O F DOO R MA X . 1/2 " MOUNTING HEIGHT PER SHEET T3.1 NOTE: 1. LEVER ON EGRESS SIDE SHALL PROVIDE FREE OPERATION w/o USE OF KEY 2. SEE SPECS FOR LEVER TYPE AND LOCKSET FUNCTION HE I G H T WIDTH HE I G H T WIDTH HE I G H T WIDTH 1 0 " M I N . FG FULL GLASS G GATEF FLUSH G1 - 1/4" CLEAR SINGLE-PANE GLASS T - DENOTES TEMPERED GLASS AT HAZARDOUS LOCATIONS WALL, PER PLAN HEADER CAULK EA. SIDE PREFINISHED KNOCK- DOWN FRAME - CONTRACTOR TO VERIFY FRAME WIDTH AT EACH DOOR DOOR PER SCHEDULE WALL, PER PLAN CAULK EA. SIDE PREFINISHED KNOCK- DOWN FRAME - CONTRACTOR TO VERIFY FRAME WIDTH AT EACH DOOR DOOR PER SCHEDULE WALL, PER SCHEDULE HEADER CAULK EA. SIDE PREFINISHED KNOCK- DOWN FRAME - CONTRACTOR TO VERIFY FRAME WIDTH AT EACH DOOR GLAZING PER SCHEDULE FIN. FLR. A SI L L H T . HE I G H T WIDTH WALL, PER SCHEDULE CAULK EA. SIDE PREFINISHED KNOCK- DOWN FRAME - CONTRACTOR TO VERIFY FRAME WIDTH AT EACH DOOR GLAZING PER SCHEDULE L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 4/6/2023 9:21:04 AM A8.1 DOOR SCHEDULE 03.03.23 PERMIT SUBMITTAL 04.06.23 PLAN CHECK 011 Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 GENERAL NOTES NO. SIZE PANEL FRAME DETAILS WIDTH HEIGHT TYPE THK MATERIAL FINISH COLOR MATERIAL FINISH COLOR HD JB JB 101.2 3' - 0" 6' - 8" F 1 3/4" H.M. PAINT ALUM. ANODIZED CLEAR A B B 102.1 3' - 0" 6' - 8" FG 1 3/4" H.M. PAINT ALUM. ANODIZED CLEAR A B B 103.1 3' - 0" 2' - 10" G 1 3/4" H.M. PAINT ALUM. ANODIZED CLEAR - B B 103.2 3' - 0" 6' - 8" F 1 3/4" H.M. PAINT ALUM. ANODIZED CLEAR A B B DOOR PANEL TYPES GLAZING LEGEND DOOR SCHEDULE 3" = 1'-0"A INT. ALUM. DOOR HEAD 3" = 1'-0"B INT. ALUM. DOOR JAMB 3" = 1'-0" C ALUM. SF. INT. HEAD NO. SIZE ELEV. TYPE GLAZING SILL HT. OPERATION FRAME DETAILS WIDTH HEIGHT MATERIAL FINISH COLOR HD JB JB SILL 1 6' - 0" 4' - 0" A G1 2' - 10" FIXED ALUM. ANODIZED CLEAR C D, SIM. D, SIM. D GLAZING SCHEDULE GLAZED FRAME TYPES 3" = 1'-0" D ALUM. SF. SILL 800 W Santa Ana Blvd. - 10111445404/06/23 24" x 24" SUSPENDED T. BAR GRID w/ LAY-IN CEILING TILE LIGHT FIXTURE -REF. ELECTRICAL DWGS. 12' - 0" CEILING HEIGHT ABOVE FINISH FLOOR LEVEL ILLUMINATED EXIT SIGN -REF. ELECTRICAL DWGS. 1. LATERAL FORCE BRACING REQUIRED FOR SUSPENDED CEILING SYSTEMS LARGER THAN 1,000 S.F. -REFER TO 2. ELECTRICAL FIXTURES SHOWN FOR COORDINATION PURPOSES ONLY. REFER TO ELECTRICAL SHEETS FOR MORE INFORMATION. D / A9.2 1 2 3 4 5 6 7 A B C AA OPEN OFFICE 100 VAULT 104 DATA 105 ELEC. 106 JAN. 109 STOR. 110 KITCHEN 111 TRAINING 112 BOARD ROOM 113 OFFICE 114 CEO OFFICE 115 OFFICE 116 QUIET ROOM 117 OPEN OFFICE 118 TOILET 108 TOILET 107 09.01 BRANCH 101 TELLERS 103 OFFICE 102 09.01 09.02 09.01 L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 4/6/2023 9:21:05 AM A9.1 REFLECTED CEILING PLAN 03.03.23 PERMIT SUBMITTAL 04.06.23 PLAN CHECK 011 Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 LEGEND GENERAL NOTES 1/8" = 1'-0" REFLECTED CEILING PLAN KEYNOTES 09.01 (E) T-BAR GRID TO REMAIN 09.02 INFILL T-BAR GRID & TILES @ (E) SOFFIT 800 W Santa Ana Blvd. - 10111445404/06/23 ATTACHED END UNATTACHED END AT T A C H E D E N D UN A T T A C H E D E N D LATERAL FORCE BRACING @ 12'-0" O.C. MAX. EA. WAY WHERE REQUIREDTYP. TYP. TYP. D A9.2 B A9.2 C A9.2 #12 GA. HANGER WIRE @ 48" O.C. w/ A MIN. OF (3) TIGHT TURNS IN 1-1/2" ATTACHMENT. SEISMIC CLIP MAIN BEAM OR CROSS RUNNER 8" MAX. 7/8" WALL ANGLE: DO NOT USE POP RIVETS TO ATTACH RUNNER TO ANGLE SCREW FASTENED PER ICC-ES REPORT & MANUFACTURER'S INSTRUCTIONS - ARMSTRONG BERC-2: ICC-ES ESR-1308 CHICAGO METALLIC 1496 CLIP: ICC-ES ESR-2282 USG/DONN ASM7 CLIP: ICC-ES ESR-1222 NOTE: SUSPENDED CEILING GRID SHALL BE RATED 'HEAVY DUTY' #12 GA. HANGER WIRE @ 48" O.C. w/ A MIN. OF (3) TIGHT TURNS IN 1-1/2" ATTACHMENT. SEISMIC CLIP MAIN BEAM OR CROSS RUNNER 8" MAX. 7/8"3/4" MIN. CLEARANCE BETWEEN RUNNER AND WALL WALL ANGLE NOTE: SUSPENDED CEILING GRID SHALL BE RATED 'HEAVY DUTY' #12 GA. HANGER WIRE @ 48" O.C. SADDLE-TIED w/ A MIN. OF (3) TIGHT TURNS IN 1-1/2" ATTACHMENT. 1-1/2" COLD-ROLLED CHANNEL @ 48" O.C. OR APPROVED MANUFACTURED T-BAR SUSPENDED CEILING SYSTEM. FURRING CLIPS FURRING CHANNELS @ 16" O.C. - 12" O.C. MAX w/ 5/8" WATER- RESISTANT GYP. BD. 5/8" SUSPENDED GYP. BD. CEILING WALL ANGLE GYP. BD., PER PLAN AND SCHEDULE 8" MAX. 5/8" MAX. 5/16" DIAM. DRILL-IN ANCHOR CEILING CLIP ASSEMBLY - BEND TO ALIGN w/ WIRE - HILTI X-CC C27 CLIP - INSTALL PER ICC-ES ESR-2184 4 TIGHT TURNS IN 1-1/2" 12 GA. SPLAYED SEISMIC BRACING WIREMAX. 1 1/2 " NOTES: 1. LOAD TEST 1 OUT OF 2 INSTALLED WIRE/ANCHOR ASSEMBLIES FOR 440 LBS. IN TENSION IN DIRECTION OF WIRE 2. REUSE OF (E) SPLAYED BRACING WIRES: ALL (E) BRACE WIRES MUST BE FIELD TESTED TO 440 POUNDS IN TENSION. THE GAGE AND SPACING OF WIRES MUST COMPLY WITH CURRENT APPLICABLE CODES. PROVIDE 2x4 BLKG. BETWEEN TRUSS AS REQUIRED 1 5 / 8 " 1-1/8" MAX. ANCHOR -1-1/8" MIN. EMBEDMENT CEILING CLIP ASSEMBLY - HILTI X-CC C27 CLIP - INSTALL PER ICC-ES ESR-2184 3 TIGHT TURNS IN 1-1/2" 12 GA. VERTICAL HANGER WIRE LOAD TEST 1 OUT OF 10 INSTALLED WIRE/ANCHOR ASSEMBLIES FOR 200 LBS. IN TENSION NOTE: REUSE OF (E) VERTICAL HANGER WIRES: ALL (E) HANGER WIRES MUST BE FIELD TESTED TO 200 POUNDS IN TENSION. THE GAGE AND SPACING OF WIRES MUST COMPLY WITH CURRENT APPLICABLE CODES. MA X. 1 1/2" 2 1/2" PROVIDE 2x4 BLKG. BETWEEN TRUSS AS REQUIRED 1 1 / 8 " CUT MTL. STUD FLANGES & BEND STUD 2-1/2" MTL. STUD COMPRESSION POST 3" MIN. WEB SIDE OF STRUT BOTTOM OF ROOF FRAMING MIN. (2) #10 S.M.S. NOTE: HORIZONTAL RESTRAINT POINTS SHALL BE PLACED @ 12' x 12' O.C. MAX. 20 GA. 2-1/2" MTL. STUD COMPRESSION POST -EXTEND TO UNDERSIDE OF ROOF STRUCTURE (4) #12 GA. WIRES SECURED TO MAIN RUNNER w/ (4) TIGHT TWISTS IN 1-1/2" & WITHIN 2" OF CROSS RUNNER INTERSECTION & SPLAYED 90° FROM EA. OTHER @ AN ANGLE NOT EXCEEDING 45° FROM THE PLANE OF THE CLG. THERE SHALL BE A RESTRAINT POINT A DISTANCE OF NOT MORE THAN 6'-0" FROM EACH SURROUNDING WALL. BRACING MEMBERS SHALL BE SPACED A MIN. OF 6" FROM HORIZ. PIPING OR DUCTWORK THAT IS NOT PROVIDED w/ BRACING RESTRAINTS FOR HORIZ. FORCES. MAIN RUNNER CROSS RUNNER (2) MIN. #10 S.M.S. ALLOW GAP FOR INSTALLATION OF CLG. TILE 2" MAX. TYP. NOTCH TO STRADDLE CROSS RUNNER H A9.2 L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 4/6/2023 9:21:06 AM A9.2 CEILING DETAILS 03.03.23 PERMIT SUBMITTAL 04.06.23 PLAN CHECK 011 Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 1/4" = 1'-0"A TYP. ACOUSTIC CEILING GRID 3" = 1'-0"B WALL CONDITION @ ATTACHED END 3" = 1'-0"C WALL CONDITION @ UNATTACHED END 3" = 1'-0" E SUSPENDED GYP. BD. CEILING 3" = 1'-0"G SPLAYED SEISMIC BRACING WIRE ATTACH. 3" = 1'-0"F VERT. HANGER WIRE ATTACH. 3" = 1'-0"H COMPRESSION POST TO STRUCT. 3" = 1'-0"D TYP. LATERAL FORCE BRACING 800 W Santa Ana Blvd. - 10111445404/06/23 WALL TO REMAIN WALL TO BE REMOVED DOOR, FRAME, AND HARDWARE TO BE REMOVED STOREFRONT SYSTEM TO BE REMOVED 1. ALL ITEMS IDENTIFIED TO BE DEMOLISHED OR REMOVED SHALL MEAN THAT THE SUBJECT ITEM IS THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE AND RECYCLED, REUSED OR LEGALLY DISPOSED OF BY THE CONTRACTOR IN ACCORDANCE WITH THE CITY OF SANTA ANA WASTE MANAGEMENT PLAN. 2. ALL ITEMS NOT IDENTIFIED TO BE DEMOLISHED OR REMOVED ARE EXISTING TO REMAIN. THE CONTRACTOR SHALL TAKE REQUIRED PRECAUTION TO PROTECT ALL EXISTING ITEMS. 1 2 3 4 5 6 7 A B C AA OFFICE D120 STORAGE D119 TRAINING D112 KITCHEN D111 RECEPTION D101 VAULT D103 DATA D104 ELEC. D105 TOILET D107 TOILET D106 OFFICE D102 JAN. D109 STORAGE D110 QUIET ROOM D117 OFFICE D116CEO OFFICE D115 OFFICE D114 BOARD ROOM D113 OPEN OFFICE D118 LOBBY D100 02.05 02.05 02.05 02.04 02.04 02.01 02.04 02.01 02.03 02.04 02.04 02.04 02.0402.02 02.01 02.04 02.02 02.04 02.02 02.01 02.04 1 2 3 4 5 6 7 A B C AA OFFICE D120 STORAGE D119 TRAINING D112 KITCHEN D111 RECEPTION D101 VAULT D103 DATA D104 ELEC. D105 TOILET D107 TOILET D106 OFFICE D102 JAN. D109 STORAGE D110 QUIET ROOM D117 OFFICE D116 CEO OFFICE D115 OFFICE D114 BOARD ROOM D113 OPEN OFFICE D118 LOBBY D100 02.32 L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 4/6/2023 9:21:07 AM D2.1 DEMOLITION FLOOR + CEILING PLANS 03.03.23 PERMIT SUBMITTAL 04.06.23 PLAN CHECK 011 Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 FLOOR PLAN LEGEND GENERAL NOTES 1/8" = 1'-0" DEMOLITION PLAN KEYNOTES 02.01 REMOVE DOOR, FRAME, AND HARDWARE 02.02 REMOVE STOREFRONT SYSTEM 02.03 REMOVE WINDOW 02.04 FRAMED WALL TO BE REMOVED FULL HEIGHT 02.05 REMOVE CABINETRY, COUNTER 02.32 REMOVE FRAMED GYPSUM BOARD CEILING, LIGHT FIXTURES, AND MECHANICAL GRILLES 1/8" = 1'-0" DEMOLITION CEILING PLAN 800 W Santa Ana Blvd. - 10111445404/06/23 1 2 3 4 5 6 7 A B C AA OPEN OFFICE 100 BRANCH 101 VAULT 104 DATA 105 ELEC. 106 JAN. 109 STOR. 110 KITCHEN 111 TRAINING 112 BOARD ROOM 113 OFFICE 114 CEO OFFICE 115 OFFICE 116 QUIET ROOM 117 OPEN OFFICE 118 TOILET 108 TOILET 107 TELLERS 103 OFFICE 102 PANEL B PANEL A (E) (E) (E) REROUTE TO (E) PANEL B REROUTE TO (E) PANEL B PANEL B PANEL B PANEL B 1 2 3 4 5 6 7 A B C AA OPEN OFFICE 100 VAULT 104 DATA 105 ELEC. 106 JAN. 109 STOR. 110 KITCHEN 111 TRAINING 112 BOARD ROOM 113 OFFICE 114 CEO OFFICE 115 OFFICE 116 QUIET ROOM 117 OPEN OFFICE 118 TOILET 108 TOILET 107 BRANCH 101 TELLERS 103 OFFICE 102 L1 PANEL A PANEL A PANEL A PANEL A PANEL A PANEL B PANEL A L1 L1 L1 L1L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1L1 L1 L1 L1 L1 L1 L1 LIGHT FIXTURE - SEE SCHEDULE SINGLE GANG SWITCH w/ OCCUPANCY SENSOR 20A DUPLEX RECEPTACLE DATA OUTLET POWER POLE ELECTRICAL PANEL 2x4 RECESSED LIGHT FIXTURE CEILING MOUNTED ILLUMINATED EXIT SIGN w/ SINGLE FACE 1. ALL DIMENSIONS ARE TO FACE OF FINISH, U.O.N. 2. GANG DEVICES WHERE POSSIBLE 3. ALL SWITCH AND RECEPTACLE FACEPLATES TO BE WHITE FINISH 4. ALL LIGHTING SWITCHES SHALL BE MOUNTED WITH TOP OF SWITCH AT 48" A.F.F. LUMINAIRE SCHEDULE - MANUFACTURER NO. MODEL - L1 2'x4' LED TROFFER DESCRIPTION LUMENS / FT - FINISH WHITE QTY. 47 OTHER FEATURES DIMMING, OCCUPANCY SENSOR L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 4/6/2023 9:21:08 AM E1.1 ELECTRICAL LIGHTING + POWER PLAN 03.03.23 PERMIT SUBMITTAL 04.06.23 PLAN CHECK 011 Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 1/8" = 1'-0" POWER PLAN 1/8" = 1'-0" LIGHTING PLAN LEGEND GENERAL NOTES 800 W Santa Ana Blvd. - 10111445404/06/23 PROJECT INFORMATION PROJECT DESCRIPTION APPLICABLE CODES INTERIOR TENANT IMPROVEMENT FOR CREDIT UNION. NO WORK TO BUILDING EXTERIOR. ALL WORK SHALL BE IN CONFORMANCE WITH THE LATEST ADOPTED AND EFFECTIVE EDITION OF TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR), AS APPLICABLE: PART 1 CALIFORNIA ADMINISTRATIVE CODE PART 2 2022 CALIFORNIA BUILDING CODE PART 3 2022 CALIFORNIA ELECTRICAL CODE PART 4 2022 CALIFORNIA MECHANICAL CODE PART 5 2022 CALIFORNIA PLUMBING CODE PART 6 2022 CALIFORNIA ENERGY CODE PART 9 2022 CALIFORNIA FIRE CODE PART 11 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE VICINITY MAP PROJECT LOCATION ADDRESS: 800 W SANTA ANA BOULEVARD SANTA ANA, CA 92701 APN: 398-212-17 ZONING: P (PROFESSIONAL) LOT AREA: 0.4 ACRE GENERAL NOTES 1. ASBESTOS CONTAINING MATERIALS MAY BE PRESENT ON SITE OR IN THE EXISTING BUILDING CONSTRUCTION. IF SUSPECT MATERIALS ARE ENCOUNTERED, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER'S REPRESENTATIVE FOR INSTRUCTIONS PRIOR TO PROCEEDING WITH ADDITIONAL WORK. THE CONTRACTOR SHALL IMMEDIATELY POST NOTICES AND TAKE THE PRECAUTIONS NECESSARY TO ENSURE THE HEALTH AND SAFETY OF ALL WORKERS, THE STAFF AND THE PUBLIC. PROJECT NORTH TRUE NORTH 1 PROJECT CONTACTS OWNER INFORMATION CONSULTANT INFORMATION OWNER SANTA ANA FEDERAL CREDIT UNION 800 W SANTA ANA BOULEVARD SANTA ANA, CA 92701 PHONE: 714.834.1341 CONTACT: JILL MAHANY, CEO WMB ARCHITECTS 5757 PACIFIC AVENUE, SUITE 226 STOCKTON, CA 95207 PHONE: 209.944.9110 FAX: 209.944.5711 EMAIL: mv@wmbarchitects.com CONTACT: MELANIE VIEUX, PROJECT ARCHITECT ARCHITECT 4 ACE CONSTRUCTION 8423 ROCHESTER AVENUE RANCHO CUCAMONGA, CA 91730 PHONE: 909.945.9100 EMAIL: scooper@4aceconstruction.com CONTACT: STEVE COOPER CONTRACTOR DETAIL DESIGNATION CENTERLINE DESIGNATION BUILDING SECTION WALL SECTION AA A4.1 A A5.1 AA A4.1 1 FINISH DESIGNATION REVISION TO DRAWINGS ROOM NAME & NUMBER NUMBERED NOTE NORTH ARROW 1 STRUCTURAL / GRID LINE ELEVATION MARKER INTERIOR ELEVATION MARKER ?00.00 A A6.1 A10.1 1 1 1 1 2 3 4 ROOM NAME 101 A P1 ALTERATION TO EXISTING BUILDING ADDITION TO EXISTING BUILDING B 7,100 S.F. 2,700 S.F. VB EXISTING FIRE SPRINKLERS 1 CHANGE OF USE (E), UNCHANGED TYPE OF CONSTRUCTION YES NUMBER OF STORIES BUILDING AREA NO OCCUPANCY GROUP BUILDING HEIGHT AREA OF WORK X X X X 77TOTAL BUILDING OCCUPANCY ACCESS COMPLIANCE DATE OF PREVIOUS ALTERATION CLAIM OF HARDSHIP UNDER CBC 11B-202.4 EXCEPTION 8 VALUATION YES $95,000 [N/A] PROJECT DATA 1 L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 4/6/2023 9:21:08 AM T1.1 TITLE SHEET 03.03.23 PERMIT SUBMITTAL 04.06.23 PLAN CHECK 011 Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 T1.1 TITLE SHEET T2.1 OCCUPANCY PLAN T2.2 CALGREEN CODE COMPLIANCE T3.1 POSTED SIGNAGE PLAN + DETAILS D2.1 DEMOLITION FLOOR + CEILING PLANS A1.1 SITE PLAN A2.1 FLOOR PLANS A6.1 DETAILS A8.1 DOOR SCHEDULE A9.1 REFLECTED CEILING PLAN A9.2 CEILING DETAILS A10.1 CASEWORK ELEVATIONS + DETAILS E1.1 ELECTRICAL LIGHTING + POWER PLAN @ AT A.F.F. ABOVE FINISH FLOOR ABV. ABOVE ADJ. ADJUSTABLE ALT. ALTERNATE ALUM. ALUMINUM APPL. APPLICABLE APPROX. APPROXIMATE B.O. BOTTOM OF BD. BOARD BLDG. BUILDING BLK. BLOCK BLKG. BLOCKING BLW. BELOW BTWN. BETWEEN C.I. CAST IRON C.I.P. CAST-IN-PLACE C.J. CONTROL JOINT C.L. CENTER LINE CBC CALIFORNIA BUILDING CODE CLG. CEILING CLR. CLEAR CMU CONCRETE MASONRY UNIT COL. COLUMN COMP. COMPACTED CONC. CONCRETE CONT. CONTINUOUS D.F. DOUGLAS FIR / DRINKING FOUNTAIN D.S. DOWNSPOUT DBL. DOUBLE DIA. DIAMETER DN. DOWN DWG. DRAWING E.I.F.S. EXTERIOR INSULATION & FINISH SYSTEM E.J. EXPANSION JOINT E.W. EACH WAY EA. EACH ELEV. ELEVATION EQ. EQUAL EXIST. / (E) EXISTING EXP. EXPANSION EXT. EXTERIOR F.D. FLOOR DRAIN F.E. FIRE EXTINGUISHER F.G. FIBERGLASS / FINISH GRADE F.H. FIRE HYDRANT F.O.F. FACE OF FINISH F.O.S. FACE OF STUD F.R.P. FIBER REINFORCED POLYMER F.S. FIRE SPRINKLERS FIN. FINISH FLR. FLOOR FT. FOOT / FEET FTG. FOOTING G.B. GRADE BREAK G.I. GALVANIZED IRON G.L.B. GLUE LAMINATED BEAM GA. GAUGE GALV. GALVANIZED GD. GRADE GYP. BD. GYPSUM BOARD H.M. HOLLOW METAL HD. HEAD HDR. HEADER HDWR. HARDWARE HORIZ. HORIZONTAL HR. HOUR HT. HEIGHT I.D. IDENTIFICATION I.S.A. INTERNATIONAL SYMBOL OF ACCESSIBILITY INSUL. INSULATION INT. INTERIOR JB. JAMB JT. JOINT LAV. LAVATORY LTWT. LIGHT WEIGHT MAX. MAXIMUM MECH. MECHANICAL MIN. MINIMUM / MINUTE MTD. MOUNTED MTL. METAL (N) NEW N.I.C. NOT IN CONTRACT N.T.S. NOT TO SCALE N/A NOT APPLICABLE NO. / # NUMBER O.C. ON CENTER OPP. OPPOSITE HAND ov/ OVER OZ. OUNCE P.F. PREFINISHED P.O.C. POINT OF CONNECTION P.T. PRESSURE TREATED PL. PLATE PLAM. PLASTIC LAMINATE PROP. PROPERTY PSI POUNDS PER SQUARE INCH PW PLYWOOD R.W.L. RAIN WATER LEADER RDWD. REDWOOD REF. REFER TO REINF. REINFORCED REQ'D. REQUIRED RM. ROOM S.C. SOLID CORE S.D. STORM DRAIN S.F. SQUARE FOOTAGE / STOREFRONT S.M. SHEET METAL S.M.S. SHEET METAL SCREW S.P. SINGLE PLY S.S. SANITARY SEWER LINE / STANDING SEAM / STAINLESS STEEL SCH. SCHEDULE SDST SELF-DRILLING SELF-TAPPING SHT. SHEET SIM. SIMILAR SPEC. SPECIFICATION SQ. SQUARE STD. STANDARD STL. STEEL SUSP. SUSPENDED T & B TOP & BOTTOM T & G TONGUE & GROOVE T.J.I. TRUS JOIST I-JOIST T.O. TOP OF T.S. TUBE STEEL TEMP TEMPORARY TYP. TYPICAL U.O.N. UNLESS OTHERWISE NOTED V.B. VAPOR BARRIER V.I.F. VERIFY IN FIELD V.T.R. VENT THROUGH ROOF VERT. VERTICAL W.C. WATER CLOSET W.H. WATER HEATER W.I. WROUGHT IRON W.W.F. WOVEN WIRE FABRIC w/ WITH w/o WITHOUT WD. WOOD ABBREVIATIONS SYMBOLS SHEET INDEX Santa Ana Federal Credit Union Tenant Improvement APN: 398-212-17 800 W Santa Ana Blvd, Santa Ana, CA 92701 800 W Santa Ana Blvd. - 10111445404/06/23 NOTES: 1. REFER TO POSTED SIGNAGE PLAN FOR LOCATION OF TACTILE EXIT SIGNS. 2. FIRE EXTINGUISHERS TO BE LOCATED BY THE FIRE MARSHAL WHERE REQUIRED. ROOM NAME ROOM AREA OCCUPANT LOAD EXITS REQUIRED OCCUPANCY LOAD FACTOR PANIC HARDWARE ILLUMINATED EXIT SIGN -REF. ELECTRICAL DWGS. NUMBER OF OCCUPANTS P 100 OCCSF/OCC LOBBY 300 SF 15 20 1 EXIT DOOR EGRESS CALCULATION NOMINAL DOOR WIDTH NET OPENING FACTOR MAX. NO. OF OCCUPANTS 36"33"0.2" / OCC.165 PR. 36"67"0.2" / OCC.335 OCCSF/OCC 935 SF 7 OPEN OFFICE 150 1 EXIT OCCSF/OCC 1,323 SF 9 BRANCH 150 1 EXIT OCCSF/OCC 120 SF 1 VAULT 150 1 EXIT OCCSF/OCC 143 SF 1 DATA 150 1 EXIT OCCSF/OCC 49 SF 1 ELEC. 300 1 EXIT TOILET JAN. OCCSF/OCC 237 SF 1 STOR. 300 1 EXIT OCCSF/OCC 270 SF 2 KITCHEN 150 1 EXIT OCCSF/OCC 116 SF 1 TRAINING 150 1 EXIT OCCSF/OCC 427 SF 29 BOARD ROOM 15 1 EXIT OCCSF/OCC 184 SF 2 OFFICE 150 1 EXIT OCCSF/OCC 248 SF 2 CEO OFFICE 150 1 EXIT OCCSF/OCC 178 SF 2 OFFICE 150 1 EXIT OCCSF/OCC 189 SF 2 QUIET ROOM 150 1 EXIT OCCSF/OCC 1,920 SF 13 OPEN OFFICE 150 1 EXIT 1554 2 29 2 2 2 2 1 1 1 2 8 1 (E) (E)(E) TOILET P 4 OCCSF/OCC 249 SF 2 TELLERS 150 1 EXIT OCCSF/OCC 159 SF 2 OFFICE 150 1 EXIT 2 36"W. DOOR36"W. DOOR PR.36" DOOR 11 1 1 1 1 L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 4/6/2023 9:21:09 AM T2.1 OCCUPANCY PLAN 03.03.23 PERMIT SUBMITTAL 04.06.23 PLAN CHECK 011 Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 LEGEND 3/32" = 1'-0" OCCUPANCY + EGRESS PLAN 800 W Santa Ana Blvd. - 10111445404/06/23 CALGREEN 2022 COMPLIANCE SCHEDULE SECTION REQUIREMENT PROJECT-SPECIFIC INFORMATION RESPONSIBILITY DOCUMENTATION VERIFICATION 5.1 5.106.1 5.106.4.1.1 5.106.4.1.2 5.106.8 5.106.10 5.3 5.303.1.1 5.303.3.1 5.303.6 5.304.1 5.4 5.407.2.1 Moisture control, sprinklers –Design and maintain landscape irrigation systems to prevent spray on structures. 5.407.2.2.1 5.408.1 Specification Section 017419 Contractor Construction Waste Management Plan + waste/recycling weight tickets and receipts Specification Section 017419 Contractor 5.408.1.1 5.408.3 5.410.1 5.410.2 SECTION REQUIREMENT PROJECT-SPECIFIC INFORMATION RESPONSIBILITY DOCUMENTATION VERIFICATION 5.5 5.503.1 Fireplaces –Install only direct-vent sealed-combustion gas or sealed wood-burning fireplaces, or a sealed wood stove or pellet stove. Wood stoves and pellet stoves shall comply with U.S. EPA NSPS emission limits. Covering of duct openings and protection of mechanical equipment during construction –All duct and air distribution component openings shall be covered with tape, plastic, and/or sheet metal during storage and rough installation until final startup in order to reduce the amount of dust and debris which may collect in the system. Contractor / Installer Adhesives, sealants and caulks shall comply with V.O.C. limits listed in Tables 5.504.4.1 + 5.504.2 Refer to Interior Finish Schedule and Specification Section 079200 Paints and coatings shall comply with V.O.C. limits listed in Table 5.504.4.3 Refer to Interior Finish Schedule and Specification Section 099100 Carpet systems (including carpet cushion) shall meet the testing and product requirements of Carpet and Rug Institute's Green Label Plus Program. Refer to Interior Finish Schedule and Specification Section 096816 and/or 096813 Refer to Interior Finish Schedule and Specification Sections 062000 + 064100 Composite wood products –Hardwood plywood, particleboard, and medium density fiberboard shall comply with formaldehyde emission limits specified in Table 5.504.4.5. No additional documentation required 5.504.3 5.504.4.1 5.504.4.3 5.504.4.4 5.504.4.5 Contractor / Installer Contractor / Installer Contractor / Installer Contractor / Installer Product data for installed materials Product data for installed materials Product data for installed materials Product data and/or certifications; chain of custody certifications Refer to Interior Finish Schedule and Specification Sections 096513, 096516, 096519, and 096566. 5.504.4.6 Contractor / Installer Product data for installed materials Air filters –Install air filtration media with a minimum MERV rating of 13 for outside and return air. 5.504.5.3 Contractor / Installer Product data and location of installed filters Environmental Tobacco Smoke control –At designated outdoor smoking areas, post signage prohibiting smoking within 25' of building entries, outdoor air intakes, and operable windows; or comply with local or applicable ordinance. 5.504.7 Indoor moisture control –Buildings shall meet or exceed provisions of California Building Code, CCR, Title 24, Part 2, Section 1202, and Chapter 14. 5.505.1 Jurisdiction No additional documentation required 5.507.4.1 Interior sound transmission –Wall and floor-ceiling assemblies separating tenant spaces from other tenant spaces or public spaces shall have an STC of at least 40. 5.507.4.3 5.508.2 5.504.1 Limit use of permanent HVAC system during construction to condition the building within the required temperature range for material and equipment installation. If the HVAC system is used during construction, use return air filters with a Minimum Efficiency Reporting Value (MERV) of 8, or an average efficiency of 30%; and replace all filters prior to occupancy. Refer to notes on mechanical plans.Contractor / Installer No additional documentation required Refer to notes on mechanical plans. Refer to notes on mechanical plans. 5.507.4.1.1 Noise exposure where noise contours not readily available –Buildings exposed to a noise level of 65 dB Leq-1- hr during any hour of operation shall have exterior wall and roof-ceiling assemblies exposed to the noise source meeting a minimum composite STC rating of 45, with exterior windows of a minimum STC of 40. 5.106.5.3 5.303.3.2 Showerheads shall have a maximum flow rate of 1.8 gal/min at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA Watersense Specification for Showerheads. 5.303.3.3.1 5.303.3.3.2 Multiple showerheads serving one shower shall have a combined maximum flow rate of 1.8 gal/min at 80 psi. Or, the shower shall be designed to allow only one showerhead to be in operation at a time. 5.407.1 Outside air delivery for mechanically or naturally ventilated spaces in buildings –Meet the minimum requirements of Section 120.1 (Requirements For Ventilation) of the California Energy Code, or applicable local code, whichever is more stringent, and Division 1, Chapter 4 of CCR, Title 8. 5.506.1 Jurisdiction No additional documentation required CO2 monitoring –For buildings or additions equipped with demand control ventilation, CO2 sensors and ventilation controls shall be specified and installed per California Energy Code, Section 120.1(c)(4). 5.506.2 5.507.4 Jurisdiction No additional documentation required Acoustical control –Employ building assemblies and components with Sound Transmission Class (STC) values determined in accordance with ASTM E90 and ASTM E413 or Outdoor-Indoor Sound Transmission Class (OITC) determined in accordance with ASTM E 1332. Performance method –For buildings located as defined in Section 5.507.4.1 or 5.507.4.1.1, wall and roof-ceiling assemblies exposed to the noise source making up the building or addition envelope or altered envelope shall be constructed to provide an interior noise environment attributable to exterior sources that does not exceed an hourly equivalent noise level of 50dBA in occupied areas during any hour of operation. 5.507.4.2 Site features –Exterior features such as sound walls or earth berms may be utilized as appropriate to the building, addition or alteration project to mitigate sound migration to the interior. 5.507.4.2.1 Documentation of compliance –An acoustical analysis documenting complying interior sound levels shall be prepared by personnel approved by the architect or engineer or record. 5.507.4.2.2 Ozone depletion and greenhouse gas reductions – Installations of HVAC, refrigeration, and fire suppression shall not contain CFCs or Halons. 5.508.1 Contractor / Installer Product data for refrigerants and/or fire suppression materials Building assemblies comply using the prescriptive method below. Refer to notes on mechanical plans. N/A -Project is an alteration and does not use new HVAC systems. 5.410.4 PLANNING + DESIGN WATER EFFICIENCY + CONSERVATION MATERIAL CONSERVATION + RESOURCE EFFICIENCY ENVIRONMENTAL QUALITY Stormwater pollution prevention –For project sites disturbing less than one acre of land, comply with local ordinances for stormwater management and/or erosion control; and/or implement BMPs for erosion/sediment control. N/A -Project does not disturb land. Short-term bicycle parking –For projects adding ten or more visitor vehicle parking spaces, provide permanently- anchored, readily-visible bicycle racks within 200' of visitors' entrance, equal to 5% of new visitor vehicle capacity (min 2). N/A -Project doesn't add visitor parking spaces. Long-term bicycle parking –For projects adding vehicular parking for 10 or more tenant-occupants, provide secure bicycle parking equal to 5% of the tenant-occupant vehicular parking spaces (minimum 1 bicycle parking facility). N/A -Project doesn't add tenant-occupant parking spaces. Electric vehicle (EV) charging –At new projects containing ten or more vehicle parking spaces, provide EV capable spaces and supply equipment (quantity per Table 5.106.5.3.1). Light pollution reduction –Design and install outdoor lighting systems to comply with the following: -Min. requirements for Lighting Zones 0-4 per CEC -Backlight ratings per IES TM-15-11 -Uplight and Glare ratings per CEC -Allowable BUG (backlight/uplight/glare) ratings per Table 5.106.8 OR comply with local ordinance, whichever is more stringent. Grading and paving –Indicate how site grading or a drainage system will manage all surface water flows to keep water from entering buildings. N/A -Project does not alter the drainage path. Water meters –In new buildings or additions in excess of 50,000 s.f., provide separate water meters or submeters for: 1. Each individual tenant space projected to consume more than 100 gal/day 2. Where submeters for individuals tenants is not feasible, add submeters to the following systems: a. Makeup water for cooling towers (where flow through > 500 gpm) b. Makeup water for evaporative coolers (where flow through > 6 gpm) c. Steam and hot-water boilers (where energy input > 500,000 Btu/h) 5.303.1.2 Water meters –Provide a separate submeter or metering device for any tenant within a new building or addition that is projected to consume more than 1,000 gal/day Water closet effective flush volume shall not exceed 1.28 gallons per flush. N/A -Project provides no new plumbing. N/A -Project provides no water closets. N/A -Project provides no urinals.Urinal flush volume shall not exceed: -0.125 gal/flush at wall-mounted urinals -0.5 gal/flush at floor-mounted or other urinals N/A -Project provides no showers. N/A -Project provides no showers. Standards –Plumbing fixtures and fittings shall be installed in accordance with the CPC, and shall meet applicable standards in Table 1701.1 of the CPC and in Ch. 6 of CGBC. N/A -Project provides no irrigation.Outdoor potable water use in landscape areas shall comply with either a local water efficient landscape ordinance, or the current California Department of Water Resources' Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent Weather protection –Provide a weather-resistant exterior wall and foundation envelope as required by California Building Code Section 1402.2, manufacturer's installation instructions, or local ordinance, whichever is more stringent. Install flashings integrated with a drainage plane. Moisture control, entries and openings – At exterior entries and/or openings which are subject to foot traffic or wind-driven rain, prevent water intrusion by: • using nonabsorbent floor and wall finishes within at least 2 feet around and perpendicular to the opening • providing 4 feet of shelter, through either an awning, an overhang, or a recess 5.407.2.2.2 Construction waste management –Recycle and/or reuse 65% min of nonhazardous construction/demolition waste (per Section 5.408.1.1, 5.408.1.2 or 5.408.1.3); or comply with local construction/demolition waste management ordinance, whichever is more stringent. N/A -Project is an alteration. N/A -Project provides no irrigation. Construction waste management plan –Where the local jurisdiction does not have a construction and demolition waste management ordinance that is more stringent, submit a construction waste management plan that complies with Section 5.408.1.1 Excavated soil and land clearing debris (trees, stumps, rocks and vegetation) shall be 100% reused or recycled Recycling by occupants –Provide an area identified and used for depositing, storage and collection of non-hazardous recyclable materials. Commissioning for new buildings 10,000 s.f. and greater: 1. Owner's Project Requirements (OPR) 2. Basis of Design (BOD) 3. Commissioning Plan 4. Functional Performance Testing 5. Documentation and training 6. Commissioning Report N/A -Project provides no fireplaces. N/A -No designated outdoor smoking area provided. N/A -Building contains no tenant spaces. Supermarket refrigerant leak reduction –New commercial refrigeration systems shall comply with the provisions of this section when installed in retail food stores that both: • have 8,000 s.f. or more of conditioned area • utilize either refrigerated display cases, walk-in coolers, or walk-in freezers connected to remote compressor units or condensing units Prescriptive method –At the locations listed below, building envelope wall and roof-ceiling assemblies shall have a minimum composite STC rating of 50, and exterior windows shall have a minimum STC rating of 40: • Within the 65 CNEL noise contour of an airport • Within the 65 CNEL or Ldn noise contour of a freeway, expressway, railroad, industrial source, or fixed guideway. N/A -Building not within 65 CNEL noise contours of an airport, freeway, expressway, railroad, industrial source, or fixed guideway. N/A -Building not exposed to noise level of 65 dB Leq-1-hr during any hour of operation. N/A -Building not within categories of sound concern. N/A -No site features provided to mitigate sound. Testing and adjusting of systems for new buildings less than 10,000 s.f.: 1. Develop a written plan of procedures for testing and adjusting HVAC systems and controls, indoor and outdoor lighting and controls, water heating systems, renewable energy systems, landscape irrigation systems, and water reuse systems, if any. 2. Perform testing, adjusting and balancing procedures in accordance with project specifications 3. Provide final report of testing signed by the individual responsible for performing the tests 4. Provide building owner with operation and maintenance manual. N/A -Project provides no commercial refrigerated display cases, walk-in coolers, or walk-in freezers Refer to notes on mechanical plans. N/A -Building not within categories of sound concern. NONRESIDENTIAL MANDATORY MEASURES pr e s c r i p t i v e m e t h o d pe r f o r m a n c e m e t h o d N/A -Building provides no new mechanical ventilation systems. Refer to wall schedules on A2.2 and roof assembly details on A7.2. N/A -Project not new or addition. N/A -Project does not alter exterior lighting. N/A -Alteration adds no square footage to the building. N/A -Alteration does not affect the building's exterior walls or foundation. N/A -Project does not alter exterior openings. N/A -Project does not disturb soil. N/A -Alteration does not affect building exterior. N/A -Project is an alteration. N/A -Project is a renovation. 5.504.4.7 5.504.4.8 Contractor / Installer Product data for installed materials Contractor / Installer Product data for installed materials Thermal Insulation –Comply with the requirements of the California Department of Public Health, “Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,” Version 1.2, January 2017. Provide verification of compliance documentation. Acoustical ceiling and wall panels –Comply with the requirements of the California Department of Public Health, “Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,” Version 1.2, January 2017. Provide verification of compliance documentation. Refer to Interior Finish Schedule and Specification Section 072100. Refer to Interior Finish Schedule and Specification Sections 092313, 095113, 095323, and 098413. 5.106.5.4 Electric vehicle (EV) charging (medium-and heavy-duty) – At new Grocery, Retail, and Warehouse buildings, provide spare raceway(s)/busway(s) and capacity for off-street loading spaces (quantity and capacity per Table 5.106.5.4.1). N/A -Project is a renovation. Resilient flooring –For 80% of the floor area receiving resilient flooring, install products complying with the California Department of Public Health, “Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,” Version 1.2, January 2017. Provide verification of compliance documentation. L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 4/6/2023 9:21:09 AM T2.2 CALGREEN CODE COMPLIANCE 03.03.23 PERMIT SUBMITTAL 04.06.23 PLAN CHECK 011 Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 800 W Santa Ana Blvd. - 10111445404/06/23 TACTILE SIGN - INSTALL ON LATCH SIDE OF DOOR * SINGLE DOOR PLAN SINGLE DOOR ELEVATION 18" x 18" CLR. FLOOR SPACE, CENTERED ON TACTILE CHARACTERS, BEYOND ARC OF DOOR TACTILE SIGN - INSTALL ON RIGHT SIDE OF DOUBLE DOORS * DOUBLE DOOR ELEVATION 9" MIN. FROM OUTSIDE EDGE OF DOOR JAMB 9" MIN. FROM OUTSIDE EDGE OF DOOR JAMB DOOR LEVER / LATCH DOOR LEVER / LATCH CONTRACTED GRADE 2 BRAILLE CENTERED BELOW ENTIRE TEXT +60" A.F.F. MAX. TO BASELINE OF HIGHEST CHARACTER +48" A.F.F. MIN. TO BASELINE OF LOWEST LINE OF BRAILLE EXIT 5/ 8 " M I N . 2" M A X . NOTES: 1. CHARACTERS, SYMBOLS AND THEIR BACKGROUND SHALL HAVE A NON -GLARE FINISH. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND (LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND) 2. REFER TO TACTILE SIGN LOCATION DETAIL FOR SIGN LOCATION RELATIVE TO DOORS 3. BRAILLE SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 11B OF THE C.B.C., LATEST EDITION 4. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION TACTILE UPPERCASE SANS-SERIF LETTERS, CHARACTERS RAISED 1/32" 3/ 8 " M I N . 1 / 2 " M A X . 3/ 8 " M I N . 1/4" RADIUS - TYP. EXIT ROUTE ALTERNATE SIGN TYPES (REFER TO SCHEDULE): OPEN OFFICE 100 VAULT 104 DATA 105 ELEC. 106 JAN. 109 STOR. 110 KITCHEN 111 TRAINING 112 BOARD ROOM 113 OFFICE 114 CEO OFFICE 115 OFFICE 116 QUIET ROOM 117 OPEN OFFICE 118 1a 1a 1a (E) (E) (E) TOILET 108 TOILET 107 BRANCH 101 TELLERS 103 OFFICE 102 HAND-ACTIVATED DOOR OPENING HARDWARE, HANDLES, PULLS, LATCHES, AND LOCKS ELEVATION VIEW PLAN VIEW PUSH SIDE PULL SIDE * 34 " M I N . 44 " M A X . PROVIDE THIS ADDITIONAL SPACE (SHADED AREA) IF DOOR IS EQUIPPED WITH BOTH A LATCH AND A CLOSER 12" MIN. THE FORCE REQUIRED TO ACTIVATE OPERABLE DOOR HARDWARE SHALL BE 5 POUNDS MAX. 60 " M I N . 48 " M I N . 24" MIN. CLR. AT EXT. DOORS 18" MIN. CLR. AT INT. DOORS 1 / 4 " M A X . 1 / 4 " M A X . 1 / 4 " M A X . 1 / 2 " M A X . VERTICAL CHANGE IN LEVEL @ FLOOR/GROUND SURFACES 1 2 MAX. SLOPE BEVELED CHANGE IN LEVEL @ FLOOR/GROUND SURFACES * 80 " M I N . 4" MAX. PROTRUSION LEADING EDGE GREATER THAN 27" A.F.F. PROTRUSIONS ABOVE MAY NOT ENCROACH INTO CIRCULATION BEYOND 80" A.F.F. 34 " M A X . 27 " M I N . 8" MIN. 11" MIN.6" MAX. 19"-25" MI N . 9" 24" MAX. COUNTERTOP OR WORK SURFACE COMBINED REQUIRED KNEE AND TOE CLEARANCE NOTE: FOR REQUIRED KNEE/TOE CLEARANCE AT LAVATORIES, REFER TO ACCESSIBLE LAVATORY DETAIL SINK, WHERE OCCURS L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 4/6/2023 9:21:10 AM T3.1 POSTED SIGNAGE PLAN + DETAILS 03.03.23 PERMIT SUBMITTAL 04.06.23 PLAN CHECK 011 Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 1/4" = 1'-0" TYP. TACTILE SIGN LOCATION AT DOOR 3" = 1'-0"A TACTILE EXIT SIGN NOTE: DETAIL REFERENCES REFER TO DETAILS THIS SHEET U.O.N. NO. SIGN TYPE TEXT DETAIL 1a TACTILE EXIT - EXTERIOR DOOR EXIT A POSTED SIGNAGE SCHEDULE 1/8" = 1'-0" POSTED SIGNAGE PLAN 1/4" = 1'-0" F ACCESSIBLE DOOR 6" = 1'-0"G VERTICAL OFFSETS 1/4" = 1'-0"4 PROTRUSION LIMITS 1/2" = 1'-0"E KNEE & TOE CLEARANCE @ WORK SURFACE 800 W Santa Ana Blvd. - 10111445404/06/23 PROJECT INFORMATION PROJECT DESCRIPTION APPLICABLE CODES INTERIOR TENANT IMPROVEMENTS FOR OFFICE SPACE. SITE WORK INCLUDES IMPROVING ACCESSIBLE PATH OF TRAVEL UNDER HARDSHIP THRESHOLD. NO CHANGES TO BUILDING SHELL, EXTERIOR FACADE, OR PARKING COUNT. ALL WORK SHALL BE IN CONFORMANCE WITH THE LATEST ADOPTED AND EFFECTIVE EDITION OF TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR), AS APPLICABLE: PART 1 CALIFORNIA ADMINISTRATIVE CODE PART 2 2022 CALIFORNIA BUILDING CODE PART 3 2022 CALIFORNIA ELECTRICAL CODE PART 4 2022 CALIFORNIA MECHANICAL CODE PART 5 2022 CALIFORNIA PLUMBING CODE PART 6 2022 CALIFORNIA ENERGY CODE PART 9 2022 CALIFORNIA FIRE CODE PART 11 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE VICINITY MAP PROJECT LOCATION ADDRESS: 800 W SANTA ANA BOULEVARD SANTA ANA, CA 92701 APN: 398-212-17 ZONING: P (PROFESSIONAL) LOT AREA: 0.4 ACRE GENERAL NOTES 1. ASBESTOS CONTAINING MATERIALS MAY BE PRESENT ON SITE OR IN THE EXISTING BUILDING CONSTRUCTION. IF SUSPECT MATERIALS ARE ENCOUNTERED, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER'S REPRESENTATIVE FOR INSTRUCTIONS PRIOR TO PROCEEDING WITH ADDITIONAL WORK. THE CONTRACTOR SHALL IMMEDIATELY POST NOTICES AND TAKE THE PRECAUTIONS NECESSARY TO ENSURE THE HEALTH AND SAFETY OF ALL WORKERS, THE STAFF AND THE PUBLIC. PROJECT NORTH TRUE NORTH PROJECT CONTACTS OWNER INFORMATION CONSULTANT INFORMATION OWNER SANTA ANA FEDERAL CREDIT UNION 800 W SANTA ANA BOULEVARD SANTA ANA, CA 92701 PHONE: 714.834.1341 CONTACT: JILL MAHANY, CEO WMB ARCHITECTS 5757 PACIFIC AVENUE, SUITE 226 STOCKTON, CA 95207 PHONE: 209.944.9110 FAX: 209.944.5711 EMAIL: mv@wmbarchitects.com CONTACT: MELANIE VIEUX, PROJECT ARCHITECT ARCHITECT 4 ACE CONSTRUCTION 8423 ROCHESTER AVENUE RANCHO CUCAMONGA, CA 91730 PHONE: 909.945.9100 EMAIL: scooper@4aceconstruction.com CONTACT: STEVE COOPER CONTRACTOR DETAIL DESIGNATION CENTERLINE DESIGNATION BUILDING SECTION WALL SECTION AA A4.1 A A5.1 AA A4.1 1 FINISH DESIGNATION REVISION TO DRAWINGS ROOM NAME & NUMBER NUMBERED NOTE NORTH ARROW 1 STRUCTURAL / GRID LINE ELEVATION MARKER INTERIOR ELEVATION MARKER ?00.00 A A6.1 A10.1 1 1 1 1 2 3 4 ROOM NAME 101 A P1 ALTERATION TO EXISTING BUILDING ADDITION TO EXISTING BUILDING B 7,100 S.F. 2,700 S.F. VB EXISTING FIRE SPRINKLERS 1 CHANGE OF USE (E), UNCHANGED TYPE OF CONSTRUCTION YES NUMBER OF STORIES BUILDING AREA NO OCCUPANCY GROUP BUILDING HEIGHT AREA OF WORK X X X X 107TOTAL BUILDING OCCUPANCY ACCESS COMPLIANCE DATE OF PREVIOUS ALTERATION CLAIM OF HARDSHIP UNDER CBC 11B-202.4 EXCEPTION 8 VALUATION YES $95,000 [N/A] PROJECT DATA L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 3/2/2023 4:30:02 PM T1.1 TITLE SHEET 03.03.23 PERMIT SUBMITTAL Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 T1.1 TITLE SHEET T2.1 OCCUPANCY PLAN T2.2 CALGREEN CODE COMPLIANCE T3.1 POSTED SIGNAGE PLAN + DETAILS D2.1 DEMOLITION FLOOR + CEILING PLANS A1.1 SITE PLAN A2.1 FLOOR PLANS A6.1 DETAILS A8.1 DOOR SCHEDULE A9.1 REFLECTED CEILING PLAN A9.2 CEILING DETAILS A10.1 CASEWORK ELEVATIONS + DETAILS E1.1 ELECTRICAL LIGHTING + POWER PLAN @ AT A.F.F. ABOVE FINISH FLOOR ABV. ABOVE ADJ. ADJUSTABLE ALT. ALTERNATE ALUM. ALUMINUM APPL. APPLICABLE APPROX. APPROXIMATE B.O. BOTTOM OF BD. BOARD BLDG. BUILDING BLK. BLOCK BLKG. BLOCKING BLW. BELOW BTWN. BETWEEN C.I. CAST IRON C.I.P. CAST-IN-PLACE C.J. CONTROL JOINT C.L. CENTER LINE CBC CALIFORNIA BUILDING CODE CLG. CEILING CLR. CLEAR CMU CONCRETE MASONRY UNIT COL. COLUMN COMP. COMPACTED CONC. CONCRETE CONT. CONTINUOUS D.F. DOUGLAS FIR / DRINKING FOUNTAIN D.S. DOWNSPOUT DBL. DOUBLE DIA. DIAMETER DN. DOWN DWG. DRAWING E.I.F.S. EXTERIOR INSULATION & FINISH SYSTEM E.J. EXPANSION JOINT E.W. EACH WAY EA. EACH ELEV. ELEVATION EQ. EQUAL EXIST. / (E) EXISTING EXP. EXPANSION EXT. EXTERIOR F.D. FLOOR DRAIN F.E. FIRE EXTINGUISHER F.G. FIBERGLASS / FINISH GRADE F.H. FIRE HYDRANT F.O.F. FACE OF FINISH F.O.S. FACE OF STUD F.R.P. FIBER REINFORCED POLYMER F.S. FIRE SPRINKLERS FIN. FINISH FLR. FLOOR FT. FOOT / FEET FTG. FOOTING G.B. GRADE BREAK G.I. GALVANIZED IRON G.L.B. GLUE LAMINATED BEAM GA. GAUGE GALV. GALVANIZED GD. GRADE GYP. BD. GYPSUM BOARD H.M. HOLLOW METAL HD. HEAD HDR. HEADER HDWR. HARDWARE HORIZ. HORIZONTAL HR. HOUR HT. HEIGHT I.D. IDENTIFICATION I.S.A. INTERNATIONAL SYMBOL OF ACCESSIBILITY INSUL. INSULATION INT. INTERIOR JB. JAMB JT. JOINT LAV. LAVATORY LTWT. LIGHT WEIGHT MAX. MAXIMUM MECH. MECHANICAL MIN. MINIMUM / MINUTE MTD. MOUNTED MTL. METAL (N) NEW N.I.C. NOT IN CONTRACT N.T.S. NOT TO SCALE N/A NOT APPLICABLE NO. / # NUMBER O.C. ON CENTER OPP. OPPOSITE HAND ov/ OVER OZ. OUNCE P.F. PREFINISHED P.O.C. POINT OF CONNECTION P.T. PRESSURE TREATED PL. PLATE PLAM. PLASTIC LAMINATE PROP. PROPERTY PSI POUNDS PER SQUARE INCH PW PLYWOOD R.W.L. RAIN WATER LEADER RDWD. REDWOOD REF. REFER TO REINF. REINFORCED REQ'D. REQUIRED RM. ROOM S.C. SOLID CORE S.D. STORM DRAIN S.F. SQUARE FOOTAGE / STOREFRONT S.M. SHEET METAL S.M.S. SHEET METAL SCREW S.P. SINGLE PLY S.S. SANITARY SEWER LINE / STANDING SEAM / STAINLESS STEEL SCH. SCHEDULE SDST SELF-DRILLING SELF-TAPPING SHT. SHEET SIM. SIMILAR SPEC. SPECIFICATION SQ. SQUARE STD. STANDARD STL. STEEL SUSP. SUSPENDED T & B TOP & BOTTOM T & G TONGUE & GROOVE T.J.I. TRUS JOIST I-JOIST T.O. TOP OF T.S. TUBE STEEL TEMP TEMPORARY TYP. TYPICAL U.O.N. UNLESS OTHERWISE NOTED V.B. VAPOR BARRIER V.I.F. VERIFY IN FIELD V.T.R. VENT THROUGH ROOF VERT. VERTICAL W.C. WATER CLOSET W.H. WATER HEATER W.I. WROUGHT IRON W.W.F. WOVEN WIRE FABRIC w/ WITH w/o WITHOUT WD. WOOD ABBREVIATIONS SYMBOLS SHEET INDEX Santa Ana Federal Credit Union Tenant Improvement APN: 398-212-17 800 W Santa Ana Blvd, Santa Ana, CA 92701 800 W Santa Ana Blvd. - 10111445404/06/23 NOTES: 1. REFER TO POSTED SIGNAGE PLAN FOR LOCATION OF TACTILE EXIT SIGNS. 2. FIRE EXTINGUISHERS TO BE LOCATED BY THE FIRE MARSHAL WHERE REQUIRED. ROOM NAME ROOM AREA OCCUPANT LOAD EXITS REQUIRED OCCUPANCY LOAD FACTOR PANIC HARDWARE ILLUMINATED EXIT SIGN -REF. ELECTRICAL DWGS. NUMBER OF OCCUPANTS P 100 OCCSF/OCC LOBBY 300 SF 15 20 1 EXIT DOOR EGRESS CALCULATION NOMINAL DOOR WIDTH NET OPENING FACTOR MAX. NO. OF OCCUPANTS 36"33"0.2" / OCC.165 PR. 36"67"0.2" / OCC.335 OCCSF/OCC 935 SF 63 OPEN OFFICE 15 2 EXITS OCCSF/OCC 1,323 SF 9 BRANCH 150 1 EXIT OCCSF/OCC 120 SF 1 VAULT 150 1 EXIT OCCSF/OCC 143 SF 1 DATA 150 1 EXIT OCCSF/OCC 49 SF 1 ELEC. 300 1 EXIT TOILET JAN. OCCSF/OCC 237 SF 1 STOR. 300 1 EXIT OCCSF/OCC 270 SF 2 KITCHEN 150 1 EXIT OCCSF/OCC 116 SF 1 TRAINING 150 1 EXIT OCCSF/OCC 427 SF 3 BOARD ROOM 150 1 EXIT OCCSF/OCC 184 SF 2 OFFICE 150 1 EXIT OCCSF/OCC 248 SF 2 CEO OFFICE 150 1 EXIT OCCSF/OCC 178 SF 2 OFFICE 150 1 EXIT OCCSF/OCC 189 SF 2 QUIET ROOM 150 1 EXIT OCCSF/OCC 1,920 SF 13 OPEN OFFICE 150 1 EXIT 32 4728 2 3 2 2 2 2 1 1 1 2 32 1 EXIT SEPARATION: 49' -10" * (½) = 24' -11" 24' - 11" < 26' -0" 49' - 10" (E) (E)(E) TOILET P P 26 ' - 0" 4 OCCSF/OCC 249 SF 2 TELLERS 150 1 EXIT OCCSF/OCC 159 SF 2 OFFICE 150 1 EXIT 2 36"W. DOOR36"W. DOOR PR.36" DOOR L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 3/2/2023 4:30:02 PM T2.1 OCCUPANCY PLAN 03.03.23 PERMIT SUBMITTAL Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 LEGEND 3/32" = 1'-0" OCCUPANCY + EGRESS PLAN 800 W Santa Ana Blvd. - 10111445404/06/23 CALGREEN 2022 COMPLIANCE SCHEDULE SECTION REQUIREMENT PROJECT-SPECIFIC INFORMATION RESPONSIBILITY DOCUMENTATION VERIFICATION 5.1 5.106.1 5.106.4.1.1 5.106.4.1.2 5.106.8 5.106.10 5.3 5.303.1.1 5.303.3.1 5.303.6 5.304.1 5.4 5.407.2.1 Moisture control, sprinklers –Design and maintain landscape irrigation systems to prevent spray on structures. 5.407.2.2.1 5.408.1 Specification Section 017419 Contractor Construction Waste Management Plan + waste/recycling weight tickets and receipts Specification Section 017419 Contractor 5.408.1.1 5.408.3 5.410.1 5.410.2 SECTION REQUIREMENT PROJECT-SPECIFIC INFORMATION RESPONSIBILITY DOCUMENTATION VERIFICATION 5.5 5.503.1 Fireplaces –Install only direct-vent sealed-combustion gas or sealed wood-burning fireplaces, or a sealed wood stove or pellet stove. Wood stoves and pellet stoves shall comply with U.S. EPA NSPS emission limits. Covering of duct openings and protection of mechanical equipment during construction –All duct and air distribution component openings shall be covered with tape, plastic, and/or sheet metal during storage and rough installation until final startup in order to reduce the amount of dust and debris which may collect in the system. Contractor / Installer Adhesives, sealants and caulks shall comply with V.O.C. limits listed in Tables 5.504.4.1 + 5.504.2 Refer to Interior Finish Schedule and Specification Section 079200 Paints and coatings shall comply with V.O.C. limits listed in Table 5.504.4.3 Refer to Interior Finish Schedule and Specification Section 099100 Carpet systems (including carpet cushion) shall meet the testing and product requirements of Carpet and Rug Institute's Green Label Plus Program. Refer to Interior Finish Schedule and Specification Section 096816 and/or 096813 Refer to Interior Finish Schedule and Specification Sections 062000 + 064100 Composite wood products –Hardwood plywood, particleboard, and medium density fiberboard shall comply with formaldehyde emission limits specified in Table 5.504.4.5. No additional documentation required 5.504.3 5.504.4.1 5.504.4.3 5.504.4.4 5.504.4.5 Contractor / Installer Contractor / Installer Contractor / Installer Contractor / Installer Product data for installed materials Product data for installed materials Product data for installed materials Product data and/or certifications; chain of custody certifications Refer to Interior Finish Schedule and Specification Sections 096513, 096516, 096519, and 096566. 5.504.4.6 Contractor / Installer Product data for installed materials Air filters –Install air filtration media with a minimum MERV rating of 13 for outside and return air. 5.504.5.3 Contractor / Installer Product data and location of installed filters Environmental Tobacco Smoke control –At designated outdoor smoking areas, post signage prohibiting smoking within 25' of building entries, outdoor air intakes, and operable windows; or comply with local or applicable ordinance. 5.504.7 Indoor moisture control –Buildings shall meet or exceed provisions of California Building Code, CCR, Title 24, Part 2, Section 1202, and Chapter 14. 5.505.1 Jurisdiction No additional documentation required 5.507.4.1 Interior sound transmission –Wall and floor-ceiling assemblies separating tenant spaces from other tenant spaces or public spaces shall have an STC of at least 40. 5.507.4.3 5.508.2 5.504.1 Limit use of permanent HVAC system during construction to condition the building within the required temperature range for material and equipment installation. If the HVAC system is used during construction, use return air filters with a Minimum Efficiency Reporting Value (MERV) of 8, or an average efficiency of 30%; and replace all filters prior to occupancy. Refer to notes on mechanical plans.Contractor / Installer No additional documentation required Refer to notes on mechanical plans. Refer to notes on mechanical plans. 5.507.4.1.1 Noise exposure where noise contours not readily available –Buildings exposed to a noise level of 65 dB Leq-1- hr during any hour of operation shall have exterior wall and roof-ceiling assemblies exposed to the noise source meeting a minimum composite STC rating of 45, with exterior windows of a minimum STC of 40. 5.106.5.3 5.303.3.2 Showerheads shall have a maximum flow rate of 1.8 gal/min at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA Watersense Specification for Showerheads. 5.303.3.3.1 5.303.3.3.2 Multiple showerheads serving one shower shall have a combined maximum flow rate of 1.8 gal/min at 80 psi. Or, the shower shall be designed to allow only one showerhead to be in operation at a time. 5.407.1 Outside air delivery for mechanically or naturally ventilated spaces in buildings –Meet the minimum requirements of Section 120.1 (Requirements For Ventilation) of the California Energy Code, or applicable local code, whichever is more stringent, and Division 1, Chapter 4 of CCR, Title 8. 5.506.1 Jurisdiction No additional documentation required CO2 monitoring –For buildings or additions equipped with demand control ventilation, CO2 sensors and ventilation controls shall be specified and installed per California Energy Code, Section 120.1(c)(4). 5.506.2 5.507.4 Jurisdiction No additional documentation required Acoustical control –Employ building assemblies and components with Sound Transmission Class (STC) values determined in accordance with ASTM E90 and ASTM E413 or Outdoor-Indoor Sound Transmission Class (OITC) determined in accordance with ASTM E 1332. Performance method –For buildings located as defined in Section 5.507.4.1 or 5.507.4.1.1, wall and roof-ceiling assemblies exposed to the noise source making up the building or addition envelope or altered envelope shall be constructed to provide an interior noise environment attributable to exterior sources that does not exceed an hourly equivalent noise level of 50dBA in occupied areas during any hour of operation. 5.507.4.2 Site features –Exterior features such as sound walls or earth berms may be utilized as appropriate to the building, addition or alteration project to mitigate sound migration to the interior. 5.507.4.2.1 Documentation of compliance –An acoustical analysis documenting complying interior sound levels shall be prepared by personnel approved by the architect or engineer or record. 5.507.4.2.2 Ozone depletion and greenhouse gas reductions – Installations of HVAC, refrigeration, and fire suppression shall not contain CFCs or Halons. 5.508.1 Contractor / Installer Product data for refrigerants and/or fire suppression materials Building assemblies comply using the prescriptive method below. Refer to notes on mechanical plans. N/A -Project is an alteration and does not use new HVAC systems. 5.410.4 PLANNING + DESIGN WATER EFFICIENCY + CONSERVATION MATERIAL CONSERVATION + RESOURCE EFFICIENCY ENVIRONMENTAL QUALITY Stormwater pollution prevention –For project sites disturbing less than one acre of land, comply with local ordinances for stormwater management and/or erosion control; and/or implement BMPs for erosion/sediment control. N/A -Project does not disturb land. Short-term bicycle parking –For projects adding ten or more visitor vehicle parking spaces, provide permanently- anchored, readily-visible bicycle racks within 200' of visitors' entrance, equal to 5% of new visitor vehicle capacity (min 2). N/A -Project doesn't add visitor parking spaces. Long-term bicycle parking –For projects adding vehicular parking for 10 or more tenant-occupants, provide secure bicycle parking equal to 5% of the tenant-occupant vehicular parking spaces (minimum 1 bicycle parking facility). N/A -Project doesn't add tenant-occupant parking spaces. Electric vehicle (EV) charging –At new projects containing ten or more vehicle parking spaces, provide EV capable spaces and supply equipment (quantity per Table 5.106.5.3.1). Light pollution reduction –Design and install outdoor lighting systems to comply with the following: -Min. requirements for Lighting Zones 0-4 per CEC -Backlight ratings per IES TM-15-11 -Uplight and Glare ratings per CEC -Allowable BUG (backlight/uplight/glare) ratings per Table 5.106.8 OR comply with local ordinance, whichever is more stringent. Grading and paving –Indicate how site grading or a drainage system will manage all surface water flows to keep water from entering buildings. N/A -Project does not alter the drainage path. Water meters –In new buildings or additions in excess of 50,000 s.f., provide separate water meters or submeters for: 1. Each individual tenant space projected to consume more than 100 gal/day 2. Where submeters for individuals tenants is not feasible, add submeters to the following systems: a. Makeup water for cooling towers (where flow through > 500 gpm) b. Makeup water for evaporative coolers (where flow through > 6 gpm) c. Steam and hot-water boilers (where energy input > 500,000 Btu/h) 5.303.1.2 Water meters –Provide a separate submeter or metering device for any tenant within a new building or addition that is projected to consume more than 1,000 gal/day Water closet effective flush volume shall not exceed 1.28 gallons per flush. N/A -Project provides no new plumbing. N/A -Project provides no water closets. N/A -Project provides no urinals.Urinal flush volume shall not exceed: -0.125 gal/flush at wall-mounted urinals -0.5 gal/flush at floor-mounted or other urinals N/A -Project provides no showers. N/A -Project provides no showers. Standards –Plumbing fixtures and fittings shall be installed in accordance with the CPC, and shall meet applicable standards in Table 1701.1 of the CPC and in Ch. 6 of CGBC. N/A -Project provides no irrigation.Outdoor potable water use in landscape areas shall comply with either a local water efficient landscape ordinance, or the current California Department of Water Resources' Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent Weather protection –Provide a weather-resistant exterior wall and foundation envelope as required by California Building Code Section 1402.2, manufacturer's installation instructions, or local ordinance, whichever is more stringent. Install flashings integrated with a drainage plane. Moisture control, entries and openings – At exterior entries and/or openings which are subject to foot traffic or wind-driven rain, prevent water intrusion by: • using nonabsorbent floor and wall finishes within at least 2 feet around and perpendicular to the opening • providing 4 feet of shelter, through either an awning, an overhang, or a recess 5.407.2.2.2 Construction waste management –Recycle and/or reuse 65% min of nonhazardous construction/demolition waste (per Section 5.408.1.1, 5.408.1.2 or 5.408.1.3); or comply with local construction/demolition waste management ordinance, whichever is more stringent. N/A -Project is an alteration. N/A -Project provides no irrigation. Construction waste management plan –Where the local jurisdiction does not have a construction and demolition waste management ordinance that is more stringent, submit a construction waste management plan that complies with Section 5.408.1.1 Excavated soil and land clearing debris (trees, stumps, rocks and vegetation) shall be 100% reused or recycled Recycling by occupants –Provide an area identified and used for depositing, storage and collection of non -hazardous recyclable materials. Commissioning for new buildings 10,000 s.f. and greater: 1. Owner's Project Requirements (OPR) 2. Basis of Design (BOD) 3. Commissioning Plan 4. Functional Performance Testing 5. Documentation and training 6. Commissioning Report N/A -Project provides no fireplaces. N/A -No designated outdoor smoking area provided. N/A -Building contains no tenant spaces. Supermarket refrigerant leak reduction –New commercial refrigeration systems shall comply with the provisions of this section when installed in retail food stores that both: • have 8,000 s.f. or more of conditioned area • utilize either refrigerated display cases, walk-in coolers, or walk-in freezers connected to remote compressor units or condensing units Prescriptive method –At the locations listed below, building envelope wall and roof-ceiling assemblies shall have a minimum composite STC rating of 50, and exterior windows shall have a minimum STC rating of 40: • Within the 65 CNEL noise contour of an airport • Within the 65 CNEL or Ldn noise contour of a freeway, expressway, railroad, industrial source, or fixed guideway. N/A -Building not within 65 CNEL noise contours of an airport, freeway, expressway, railroad, industrial source, or fixed guideway. N/A -Building not exposed to noise level of 65 dB Leq-1-hr during any hour of operation. N/A -Building not within categories of sound concern. N/A -No site features provided to mitigate sound. Testing and adjusting of systems for new buildings less than 10,000 s.f.: 1. Develop a written plan of procedures for testing and adjusting HVAC systems and controls, indoor and outdoor lighting and controls, water heating systems, renewable energy systems, landscape irrigation systems, and water reuse systems, if any. 2. Perform testing, adjusting and balancing procedures in accordance with project specifications 3. Provide final report of testing signed by the individual responsible for performing the tests 4. Provide building owner with operation and maintenance manual. N/A -Project provides no commercial refrigerated display cases, walk-in coolers, or walk-in freezers Refer to notes on mechanical plans. N/A -Building not within categories of sound concern. NONRESIDENTIAL MANDATORY MEASURES pr e s c r i p t i v e m e t h o d pe r f o r m a n c e m e t h o d N/A -Building provides no new mechanical ventilation systems. Refer to wall schedules on A2.2 and roof assembly details on A7.2. N/A -Project not new or addition. N/A -Project does not alter exterior lighting. N/A -Alteration adds no square footage to the building. N/A -Alteration does not affect the building's exterior walls or foundation. N/A -Project does not alter exterior openings. N/A -Project does not disturb soil. N/A -Alteration does not affect building exterior. N/A -Project is an alteration. N/A -Project is a renovation. 5.504.4.7 5.504.4.8 Contractor / Installer Product data for installed materials Contractor / Installer Product data for installed materials Thermal Insulation –Comply with the requirements of the California Department of Public Health, “Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,” Version 1.2, January 2017. Provide verification of compliance documentation. Acoustical ceiling and wall panels –Comply with the requirements of the California Department of Public Health, “Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,” Version 1.2, January 2017. Provide verification of compliance documentation. Refer to Interior Finish Schedule and Specification Section 072100. Refer to Interior Finish Schedule and Specification Sections 092313, 095113, 095323, and 098413. 5.106.5.4 Electric vehicle (EV) charging (medium-and heavy-duty) – At new Grocery, Retail, and Warehouse buildings, provide spare raceway(s)/busway(s) and capacity for off-street loading spaces (quantity and capacity per Table 5.106.5.4.1). N/A -Project is a renovation. Resilient flooring –For 80% of the floor area receiving resilient flooring, install products complying with the California Department of Public Health, “Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,” Version 1.2, January 2017. Provide verification of compliance documentation. L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 3/2/2023 4:30:02 PM T2.2 CALGREEN CODE COMPLIANCE 03.03.23 PERMIT SUBMITTAL Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 800 W Santa Ana Blvd. - 10111445404/06/23 TACTILE SIGN - INSTALL ON LATCH SIDE OF DOOR * SINGLE DOOR PLAN SINGLE DOOR ELEVATION 18" x 18" CLR. FLOOR SPACE, CENTERED ON TACTILE CHARACTERS, BEYOND ARC OF DOOR TACTILE SIGN - INSTALL ON RIGHT SIDE OF DOUBLE DOORS * DOUBLE DOOR ELEVATION 9" MIN. FROM OUTSIDE EDGE OF DOOR JAMB 9" MIN. FROM OUTSIDE EDGE OF DOOR JAMB DOOR LEVER / LATCH DOOR LEVER / LATCH CONTRACTED GRADE 2 BRAILLE CENTERED BELOW ENTIRE TEXT +60" A.F.F. MAX. TO BASELINE OF HIGHEST CHARACTER +48" A.F.F. MIN. TO BASELINE OF LOWEST LINE OF BRAILLE EXIT 5/ 8 " M I N . 2" M A X . NOTES: 1. CHARACTERS, SYMBOLS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND (LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND) 2. REFER TO TACTILE SIGN LOCATION DETAIL FOR SIGN LOCATION RELATIVE TO DOORS 3. BRAILLE SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 11B OF THE C.B.C., LATEST EDITION 4. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION TACTILE UPPERCASE SANS-SERIF LETTERS, CHARACTERS RAISED 1/32" 3/ 8 " M I N . 1/ 2 " M A X . 3/ 8 " M I N . 1/4" RADIUS - TYP. EXIT ROUTE ALTERNATE SIGN TYPES (REFER TO SCHEDULE): OPEN OFFICE 100 VAULT 104 DATA 105 ELEC. 106 JAN. 109 STOR. 110 KITCHEN 111 TRAINING 112 BOARD ROOM 113 OFFICE 114 CEO OFFICE 115 OFFICE 116 QUIET ROOM 117 OPEN OFFICE 118 1b 1a 1a 1a (E) (E) (E) TOILET 108 TOILET 107 BRANCH 101 TELLERS 103 OFFICE 102 HAND-ACTIVATED DOOR OPENING HARDWARE, HANDLES, PULLS, LATCHES, AND LOCKS ELEVATION VIEW PLAN VIEW PUSH SIDE PULL SIDE * 34 " M I N . 44 " M A X . PROVIDE THIS ADDITIONAL SPACE (SHADED AREA) IF DOOR IS EQUIPPED WITH BOTH A LATCH AND A CLOSER 12" MIN. THE FORCE REQUIRED TO ACTIVATE OPERABLE DOOR HARDWARE SHALL BE 5 POUNDS MAX. 60 " M I N . 48 " M I N . 24" MIN. CLR. AT EXT. DOORS 18" MIN. CLR. AT INT. DOORS 1/ 4 " M A X . 1/ 4 " M A X . 1/ 4 " M A X . 1/ 2 " M A X . VERTICAL CHANGE IN LEVEL @ FLOOR/GROUND SURFACES 1 2 MAX. SLOPE BEVELED CHANGE IN LEVEL @ FLOOR/GROUND SURFACES * 80 " M I N . 4" MAX. PROTRUSION LEADING EDGE GREATER THAN 27" A.F.F. PROTRUSIONS ABOVE MAY NOT ENCROACH INTO CIRCULATION BEYOND 80" A.F.F. 34 " M A X . 27 " M I N . 8" MIN. 11" MIN.6" MAX. 19"-25" MI N . 9" 24" MAX. COUNTERTOP OR WORK SURFACE COMBINED REQUIRED KNEE AND TOE CLEARANCE NOTE: FOR REQUIRED KNEE/TOE CLEARANCE AT LAVATORIES, REFER TO ACCESSIBLE LAVATORY DETAIL SINK, WHERE OCCURS L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 3/2/2023 4:30:02 PM T3.1 POSTED SIGNAGE PLAN + DETAILS 03.03.23 PERMIT SUBMITTAL Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 1/4" = 1'-0" TYP. TACTILE SIGN LOCATION AT DOOR 3" = 1'-0"A TACTILE EXIT SIGN NOTE: DETAIL REFERENCES REFER TO DETAILS THIS SHEET U.O.N. NO. SIGN TYPE TEXT DETAIL 1a TACTILE EXIT - EXTERIOR DOOR EXIT A 1b TACTILE EXIT - INTERIOR DOOR EXIT ROUTE A POSTED SIGNAGE SCHEDULE 1/8" = 1'-0" POSTED SIGNAGE PLAN 1/4" = 1'-0" F ACCESSIBLE DOOR 6" = 1'-0"G VERTICAL OFFSETS 1/4" = 1'-0"4 PROTRUSION LIMITS 1/2" = 1'-0"E KNEE & TOE CLEARANCE @ WORK SURFACE 800 W Santa Ana Blvd. - 10111445404/06/23 WALL TO REMAIN WALL TO BE REMOVED DOOR, FRAME, AND HARDWARE TO BE REMOVED STOREFRONT SYSTEM TO BE REMOVED 1. ALL ITEMS IDENTIFIED TO BE DEMOLISHED OR REMOVED SHALL MEAN THAT THE SUBJECT ITEM IS THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE AND RECYCLED, REUSED OR LEGALLY DISPOSED OF BY THE CONTRACTOR IN ACCORDANCE WITH THE CITY OF SANTA ANA WASTE MANAGEMENT PLAN. 2. ALL ITEMS NOT IDENTIFIED TO BE DEMOLISHED OR REMOVED ARE EXISTING TO REMAIN. THE CONTRACTOR SHALL TAKE REQUIRED PRECAUTION TO PROTECT ALL EXISTING ITEMS. 1 2 3 4 5 6 7 A B C AA OFFICE D120 STORAGE D119 TRAINING D112 KITCHEN D111 RECEPTION D101 VAULT D103 DATA D104 ELEC. D105 TOILET D107 TOILET D106 OFFICE D102 JAN. D109 STORAGE D110 QUIET ROOM D117 OFFICE D116CEO OFFICE D115 OFFICE D114 BOARD ROOM D113 OPEN OFFICE D118 LOBBY D100 02.05 02.05 02.05 02.04 02.04 02.01 02.04 02.01 02.03 02.04 02.04 02.04 02.0402.02 02.01 02.04 02.02 02.04 02.02 02.01 02.04 1 2 3 4 5 6 7 A B C AA OFFICE D120 STORAGE D119 TRAINING D112 KITCHEN D111 RECEPTION D101 VAULT D103 DATA D104 ELEC. D105 TOILET D107 TOILET D106 OFFICE D102 JAN. D109 STORAGE D110 QUIET ROOM D117 OFFICE D116CEO OFFICE D115 OFFICE D114 BOARD ROOM D113 OPEN OFFICE D118 LOBBY D100 02.32 L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 3/2/2023 4:30:01 PM D2.1 DEMOLITION FLOOR + CEILING PLANS 03.03.23 PERMIT SUBMITTAL Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 FLOOR PLAN LEGEND GENERAL NOTES 1/8" = 1'-0" DEMOLITION PLAN KEYNOTES 02.01 REMOVE DOOR, FRAME, AND HARDWARE 02.02 REMOVE STOREFRONT SYSTEM 02.03 REMOVE WINDOW 02.04 FRAMED WALL TO BE REMOVED FULL HEIGHT 02.05 REMOVE CABINETRY, COUNTER 02.32 REMOVE FRAMED GYPSUM BOARD CEILING, LIGHT FIXTURES, AND MECHANICAL GRILLES 1/8" = 1'-0" DEMOLITION CEILING PLAN 800 W Santa Ana Blvd. - 10111445404/06/23 ACCESSIBLE PEDESTRIAN ROUTE: MIN. WIDTH = 48" MAX. SURFACE SLOPES: CROSS SLOPE = 1:48" MAX. SLOPE IN DIRECTION OF TRAVEL = 1:20 MAX. RUNNING SLOPE ON RAMPS AND CURB RAMPS = 1:12 MAX. NO VERTICAL OFFSETS IN EXCESS OF 1/4" W E S T S A N T A A N A B O U L E V A R D W E S T 3 R D S T R E E T EXISTING BUILDING (AREA OF WORK) EXISTING ACCESSIBLE PARKING TO REMAIN L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 3/2/2023 4:29:59 PM A1.1 SITE PLAN 03.03.23 PERMIT SUBMITTAL Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 LEGEND 1/4" = 1'-0" SITE PLAN NOT TO SCALEPROJECT NORTH TRUE NORTH 800 W Santa Ana Blvd. - 10111445404/06/23 1 2 3 4 5 6 7 A B C AA OPEN OFFICE 100 VAULT 104 DATA 105 ELEC. 106 TOILET 108 JAN. 109 STOR. 110 KITCHEN 111 TRAINING 112 BOARD ROOM 113 OFFICE 114 CEO OFFICE 115 OFFICE 116 QUIET ROOM 117 OPEN OFFICE 118 TOILET 107 AL I G N MIN. 3' - 0" 11 ' - 9 " 14 ' - 1 0 " BRANCH 101 TELLERS 103 OFFICE 102 6' - 0 " 5' - 1 0 " 5 1 / 2 " COUNTERS SHOWN DASHED FOR CLARITY 8' - 3 1/2" 5' - 0 1/2" 2' - 1 1/2" 4' - 9" 2' - 3" 14' - 4" 1 2 3 4 5 6 7 A B C AA OPEN OFFICE 100 BRANCH 101 VAULT 104 DATA 105 ELEC. 106 JAN. 109 STOR. 110 KITCHEN 111 TRAINING 112 BOARD ROOM 113 OFFICE 114 CEO OFFICE 115 OFFICE 116 QUIET ROOM 117 101.2 OPEN OFFICE 118 1 1 1 4 TOILET 108 TOILET 107 06.01 06.01 06.01 06.01 06.01 06.01 06.01 103.2 102.1 103.1 101.1 100.1 101.3 1 1 1 TELLERS 103 OFFICE 102 1 5 3 1 6 5 5 3 3 6 05.01 5 4 7 22 05.01 1. ALL DIMENSIONS ARE TO FACE OF STUD OR FACE OF EXISTING FINISH, U.O.N. 2. SCHEDULED DETAILS REFER TO DETAILS ON SHEET A6.1, U.O.N. 3. REFER TO SHEET FOR POSTED SIGNAGE 4. INTERIOR SHEAR PLY NOT INDICATED -COORDINATE LOCATIONS w/ STRUCTURAL DRAWINGS 5. PROVIDE MOISTURE-RESISTANT GYP. BD. AT ALL WET LOCATIONS AND/OR TO RECEIVE WALL TILE -REFER TO SHEET A10.1 6. FOR ALL EXISTING SURFACES DISTURBED BY THE NEW CONSTRUCTION: PATCH, REPAIR, AND REFINISH TO MATCH. UPON COMPLETION OF THE PROJECT, THERE SHALL BE NO VISUAL DIFFERENCE BETWEEN THE NEW WORK AND EXISTING CONDITIONS. 7. REFER TO DETAIL FOR CONC. SLAB REPAIR T3.1 G / A6.1 INTERIOR WALL TYPE - REF. SCHEDULE THIS SHEET 101.1 DOOR NUMBER -REF. A8.1 FOR SCHEDULE GLAZED FRAME NUMBER - REF. A8.1 FOR SCHEDULE CABINET ELEVATION - REF. A11.11 1 EXISTING WALL TO REMAIN NEW WALL 1 ALIGN ADJACENT FINISH SURFACES CENTERLINE DESIGNATION L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 3/2/2023 4:30:00 PM A2.1 FLOOR PLANS 03.03.23 PERMIT SUBMITTAL Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 1/8" = 1'-0" DIMENSION PLAN 1/8" = 1'-0" NOTATION PLAN GENERAL NOTES NO. CORE INSUL. WALLBD. EXTENT DETAILS HEAD SILL 1 2x4 D.F. STUDS @ 16" O.C. ACOUST. F.G. BATT. 5/8" GYP. BD. BOTH SIDES CORE, INSUL. & WALLBD. TO 6" ABOVE FINISH CEILING D E 2 2x4 D.F. STUDS @ 16" O.C. - 3/4" PLYWOOD BOTH SIDES CORE & WALLBD. TO 2'-10" A.F.F. - F, SIM. 3 2x4 D.F. STUDS @ 16" O.C. - 3/4" PLYWOOD BOTH SIDES CORE & WALLBD. TO 4'-7" A.F.F. - F, SIM. 4 2x6 D.F. STUDS @ 16" O.C. - 5/8" GYP. BD. BOTH SIDES CORE & WALLBD. TO 6" ABOVE FINISH CEILING D, SIM. E, SIM. 5 2x6 D.F. STUDS @ 16" O.C. - 3/4" PLYWOOD BOTH SIDES CORE & WALLBD. TO 2'-10" A.F.F. C / A11.1 F 6 2x6 D.F. STUDS @ 16" O.C. - 3/4" PLYWOOD BOTH SIDES CORE & WALLBD. TO 3'-5" A.F.F. A & B / A11.1 F 7 2x6 D.F. STUDS @ 16" O.C. - 3/4" PLYWOOD BOTH SIDES CORE & WALLBD. TO 4'-7" A.F.F. D / A11.1 F KEYNOTES 05.01 2½" DIA. STAINLESS STEEL GROMMET 06.01 PATCH & REPAIR GYP. BD. AS REQ'D FROM DEMOLITION LEGEND INTERIOR WALL SCHEDULE 800 W Santa Ana Blvd. - 10111445404/06/23 4x6 BLOCKING -TOE NAIL w/ (4) 10d NAILS 2x WOOD STUDS FOR GRAB BARS / WALL HUNG LAVS / ITEMS NOT NOTED. MOUNT USING #14 SELF-TAPPING S.M.S. TYPE C FOR TOILET ACCESSORIES EXCLUDING GRAB BARS. MOUNT USING #10 WOOD SCREWS. TYPE A 2x WOOD STUDS 6" x 16 GA STEEL PLATE SECURE TO STUDS w/ (2) #10 x 1/2" S.M.S. LENGTH AS REQ'D TO SUPPORT ITEM 2x WOOD STUDS 2x6 BLOCKING - TOE NAIL w/ (4) 10d NAILS TYPE B FOR MED. GAS PANELS / BASE CABINETS / WALL GUARDS / WALL HUNG CABINETS / WALL HUNG EQUIP. MOUNT USING #12 WOOD SCREWS. STD. STUD SPAC I N G STD. STUD SPAC I N G STD. STUD SPAC ING LENGTH AS REQ'D TO SUPPORT ITEM LENGTH AS REQ'D TO SUPPORT ITEM SOUND ATTENUATION BATTS 5/8" GYPSUM BOARD 2x4 D.F. STUDS 5/8" GYPSUM BOARD 2x PRESSURE-TREATED SILL PLATE w/ POWDER-DRIVEN ANCHORS @ 32" O.C. (E) SLAB ON GRADE 2x4 D.F. ANGLED DIAGONAL BRACING @ 48" O.C. -ALTERNATE DIRECTION. DECK ATTACHMENT REFER TO TRACK w/ (2) #8 SCREWS @ EA. STUD 2x BLOCKING TYP. @ CEILING 6" M I N . 16 GA. x 1½" x 1½" x 3" LONG CLIP ANGLE w/ (2) #8 SCREWS EA. TO BRACE & TRACK WALL, PER SCHEDULE C A6.1 1' - 6" MAX. 4" EQ EQ EMBED 4" COMPACTED TRENCH MATERIALS COMPACTED SAND OR CLASS II AGGREGATE BASE (CONCRETE FILL OPTIONAL) SAWCUT (E) SLAB #4 DOWEL @ 24" O.C. EACH SIDE (N) 3000 PSI CONC. FILL CLEAN CUT SURFACE -APPLY CONC. BONDING AGENT - TYP. 4" FIRECAULK ALL CONDUIT PENETRATIONS 5/8" TYPE 'X' GYPSUM BOARD WALL, PER SCHEDULE 2x BLOCKING ALL AROUND 2x BLOCKING 2 1/2" SEMI-RECESSED FIRE EXTINGUISHER CABINET 4' -0" MAX. A.F.F. PROVIDE 2x4 BLKG. BETWEEN TRUSS AS REQUIRED 2x4 D.F. @ 48" O.C. ANGLE BRACING- ALTERNATE DIRECTION SUSPENDED ACOUSTICAL CEILING WALL, PER PLAN QUARTZ COUNTER TOP 3/4" PLYWOOD 1/4" RADIUS, TYP. 3/4" PLYWOOD EA. SIDE BASE 2x6 D.F. STUDS @ 16" O.C. 2x BLOCKING 4" VA R I E S - R E F . W A L L S C H E D U L E 11 1/2" PLASTIC LAMINATE EA. SIDE PL1 B1 Q1 2x PRESSURE-TREATED SILL PLATE w/ POWDER-DRIVEN ANCHORS @ 32" O.C. (E) SLAB ON GRADE L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 3/2/2023 4:30:00 PM A6.1 DETAILS 03.03.23 PERMIT SUBMITTAL Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 1/4" = 1'-0"A TYP. BACKING PLATES 3" = 1'-0" E WALL BASE 3" = 1'-0"D TOP OF WALL @ BRACING 1 1/2" = 1'-0" G CONC. SLAB REPAIR 3" = 1'-0"B TYP. FIRE EXTINGUISHER CABINET 1/2" = 1'-0"C WOOD STUD BRACES, NON-BEARING WALL 1 1/2" = 1'-0"F LOW WALL 800 W Santa Ana Blvd. - 10111445404/06/23 1. MAXIMUM VERTICAL OFFSET AT DOOR THRESHOLD SHALL BE 1/4" VERTICAL OR 1/2" IF BEVELED - REFER TO THRESHOLD DETAIL(S). 2. ALL DOORS THAT ARE PART OF THE MEANS OF EGRESS SHALL BE EQUIPPED WITH HARDWARE THAT OPENS THE DOOR FROM THE INTERIOR WITHOUT SPECIAL KNOWLEDGE, EFFORT, OR A KEY. 3. MAXIMUM DOOR OPENING EFFORT SHALL BE 5# AT NON-RATED DOORS AND 15# AT FIRE RATED DOORS. 4. SEE SPECIFICATIONS FOR DOOR HARDWARE SETS AND PRODUCTS. 5. ALL GLASS IN DOOR PANELS TO BE TEMPERED. 6. REFER TO SHEET A10.1 FOR FINISH CODE LEGEND 7. SCHEDULED DETAILS REFER TO DETAILS ON THIS SHEET U.O.N. 8. OPERATING HARDWARE FOR LOCKSETS/LATCHSETS SHALL BE LEVER TYPE: FACE O F DOO R MA X . 1/2 " MOUNTING HEIGHT PER SHEET T3.1 NOTE: 1. LEVER ON EGRESS SIDE SHALL PROVIDE FREE OPERATION w/o USE OF KEY 2. SEE SPECS FOR LEVER TYPE AND LOCKSET FUNCTION HE I G H T WIDTH HE I G H T WIDTH HE I G H T WIDTH 10 " M I N . FG FULL GLASS G GATEF FLUSH G1 - 1/4" CLEAR SINGLE-PANE GLASS T - DENOTES TEMPERED GLASS AT HAZARDOUS LOCATIONS WALL, PER PLAN HEADER CAULK EA. SIDE PREFINISHED KNOCK- DOWN FRAME - CONTRACTOR TO VERIFY FRAME WIDTH AT EACH DOOR DOOR PER SCHEDULE WALL, PER PLAN CAULK EA. SIDE PREFINISHED KNOCK- DOWN FRAME - CONTRACTOR TO VERIFY FRAME WIDTH AT EACH DOOR DOOR PER SCHEDULE WALL, PER SCHEDULE HEADER CAULK EA. SIDE PREFINISHED KNOCK- DOWN FRAME - CONTRACTOR TO VERIFY FRAME WIDTH AT EACH DOOR GLAZING PER SCHEDULE FIN. FLR. A SI L L H T . HE I G H T WIDTH WALL, PER SCHEDULE CAULK EA. SIDE PREFINISHED KNOCK- DOWN FRAME - CONTRACTOR TO VERIFY FRAME WIDTH AT EACH DOOR GLAZING PER SCHEDULE L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 3/2/2023 4:30:00 PM A8.1 DOOR SCHEDULE 03.03.23 PERMIT SUBMITTAL Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 GENERAL NOTES NO. SIZE PANEL FRAME DETAILS WIDTH HEIGHT TYPE THK MATERIAL FINISH COLOR MATERIAL FINISH COLOR HD JB JB 101.2 3' - 0" 6' - 8" F 1 3/4" H.M. PAINT ALUM. ANODIZED CLEAR A B B 102.1 3' - 0" 6' - 8" FG 1 3/4" H.M. PAINT ALUM. ANODIZED CLEAR A B B 103.1 3' - 0" 2' - 10" G 1 3/4" H.M. PAINT ALUM. ANODIZED CLEAR - B B 103.2 3' - 0" 6' - 8" F 1 3/4" H.M. PAINT ALUM. ANODIZED CLEAR A B B DOOR PANEL TYPES GLAZING LEGEND DOOR SCHEDULE 3" = 1'-0"A INT. ALUM. DOOR HEAD 3" = 1'-0"B INT. ALUM. DOOR JAMB 3" = 1'-0" C ALUM. SF. INT. HEAD NO. SIZE ELEV. TYPE GLAZING SILL HT. OPERATION FRAME DETAILS WIDTH HEIGHT MATERIAL FINISH COLOR HD JB JB SILL 1 6' - 0" 4' - 0" A G1 2' - 10" FIXED ALUM. ANODIZED CLEAR C D, SIM. D, SIM. D GLAZING SCHEDULE GLAZED FRAME TYPES 3" = 1'-0" D ALUM. SF. SILL 800 W Santa Ana Blvd. - 10111445404/06/23 24" x 24" SUSPENDED T. BAR GRID w/ LAY-IN CEILING TILE LIGHT FIXTURE -REF. ELECTRICAL DWGS. 12' - 0" CEILING HEIGHT ABOVE FINISH FLOOR LEVEL ILLUMINATED EXIT SIGN -REF. ELECTRICAL DWGS. 1. LATERAL FORCE BRACING REQUIRED FOR SUSPENDED CEILING SYSTEMS LARGER THAN 1,000 S.F. -REFER TO 2. ELECTRICAL FIXTURES SHOWN FOR COORDINATION PURPOSES ONLY. REFER TO ELECTRICAL SHEETS FOR MORE INFORMATION. D / A9.2 1 2 3 4 5 6 7 A B C AA OPEN OFFICE 100 VAULT 104 DATA 105 ELEC. 106 JAN. 109 STOR. 110 KITCHEN 111 TRAINING 112 BOARD ROOM 113 OFFICE 114 CEO OFFICE 115 OFFICE 116 QUIET ROOM 117 OPEN OFFICE 118 TOILET 108 TOILET 107 09.01 BRANCH 101 TELLERS 103 OFFICE 102 09.01 09.02 09.01 L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 3/2/2023 4:30:00 PM A9.1 REFLECTED CEILING PLAN 03.03.23 PERMIT SUBMITTAL Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 LEGEND GENERAL NOTES 1/8" = 1'-0" REFLECTED CEILING PLAN KEYNOTES 09.01 (E) T-BAR GRID TO REMAIN 09.02 INFILL T-BAR GRID & TILES @ (E) SOFFIT 800 W Santa Ana Blvd. - 10111445404/06/23 ATTACHED END UNATTACHED END AT T A C H E D E N D UN A T T A C H E D E N D LATERAL FORCE BRACING @ 12'-0" O.C. MAX. EA. WAY WHERE REQUIREDTYP. TYP. TYP. D A9.2 B A9.2 C A9.2 #12 GA. HANGER WIRE @ 48" O.C. w/ A MIN. OF (3) TIGHT TURNS IN 1-1/2" ATTACHMENT. SEISMIC CLIP MAIN BEAM OR CROSS RUNNER 8" MAX. 7/8" WALL ANGLE: DO NOT USE POP RIVETS TO ATTACH RUNNER TO ANGLE SCREW FASTENED PER ICC-ES REPORT & MANUFACTURER'S INSTRUCTIONS - ARMSTRONG BERC-2: ICC-ES ESR-1308 CHICAGO METALLIC 1496 CLIP: ICC-ES ESR-2282 USG/DONN ASM7 CLIP: ICC-ES ESR-1222 NOTE: SUSPENDED CEILING GRID SHALL BE RATED 'HEAVY DUTY' #12 GA. HANGER WIRE @ 48" O.C. w/ A MIN. OF (3) TIGHT TURNS IN 1-1/2" ATTACHMENT. SEISMIC CLIP MAIN BEAM OR CROSS RUNNER 8" MAX. 7/8"3/4" MIN. CLEARANCE BETWEEN RUNNER AND WALL WALL ANGLE NOTE: SUSPENDED CEILING GRID SHALL BE RATED 'HEAVY DUTY' #12 GA. HANGER WIRE @ 48" O.C. SADDLE-TIED w/ A MIN. OF (3) TIGHT TURNS IN 1-1/2" ATTACHMENT. 1-1/2" COLD-ROLLED CHANNEL @ 48" O.C. OR APPROVED MANUFACTURED T-BAR SUSPENDED CEILING SYSTEM. FURRING CLIPS FURRING CHANNELS @ 16" O.C. - 12" O.C. MAX w/ 5/8" WATER- RESISTANT GYP. BD. 5/8" SUSPENDED GYP. BD. CEILING WALL ANGLE GYP. BD., PER PLAN AND SCHEDULE 8" MAX. 5/8" MAX. 5/16" DIAM. DRILL-IN ANCHOR CEILING CLIP ASSEMBLY - BEND TO ALIGN w/ WIRE - HILTI X-CC C27 CLIP - INSTALL PER ICC-ES ESR-2184 4 TIGHT TURNS IN 1-1/2" 12 GA. SPLAYED SEISMIC BRACING WIREMAX. 1 1/2 " NOTES: 1. LOAD TEST 1 OUT OF 2 INSTALLED WIRE/ANCHOR ASSEMBLIES FOR 440 LBS. IN TENSION IN DIRECTION OF WIRE 2. REUSE OF (E) SPLAYED BRACING WIRES: ALL (E) BRACE WIRES MUST BE FIELD TESTED TO 440 POUNDS IN TENSION. THE GAGE AND SPACING OF WIRES MUST COMPLY WITH CURRENT APPLICABLE CODES. PROVIDE 2x4 BLKG. BETWEEN TRUSS AS REQUIRED 1 5 / 8 " 1-1/8" MAX. ANCHOR -1-1/8" MIN. EMBEDMENT CEILING CLIP ASSEMBLY - HILTI X-CC C27 CLIP - INSTALL PER ICC-ES ESR-2184 3 TIGHT TURNS IN 1-1/2" 12 GA. VERTICAL HANGER WIRE LOAD TEST 1 OUT OF 10 INSTALLED WIRE/ANCHOR ASSEMBLIES FOR 200 LBS. IN TENSION NOTE: REUSE OF (E) VERTICAL HANGER WIRES: ALL (E) HANGER WIRES MUST BE FIELD TESTED TO 200 POUNDS IN TENSION. THE GAGE AND SPACING OF WIRES MUST COMPLY WITH CURRENT APPLICABLE CODES. MA X. 1 1/2" 2 1/2" PROVIDE 2x4 BLKG. BETWEEN TRUSS AS REQUIRED 1 1 / 8 " CUT MTL. STUD FLANGES & BEND STUD 2-1/2" MTL. STUD COMPRESSION POST 3" MIN. WEB SIDE OF STRUT BOTTOM OF ROOF FRAMING MIN. (2) #10 S.M.S. NOTE: HORIZONTAL RESTRAINT POINTS SHALL BE PLACED @ 12' x 12' O.C. MAX. 20 GA. 2-1/2" MTL. STUD COMPRESSION POST -EXTEND TO UNDERSIDE OF ROOF STRUCTURE (4) #12 GA. WIRES SECURED TO MAIN RUNNER w/ (4) TIGHT TWISTS IN 1-1/2" & WITHIN 2" OF CROSS RUNNER INTERSECTION & SPLAYED 90° FROM EA. OTHER @ AN ANGLE NOT EXCEEDING 45° FROM THE PLANE OF THE CLG. THERE SHALL BE A RESTRAINT POINT A DISTANCE OF NOT MORE THAN 6'-0" FROM EACH SURROUNDING WALL. BRACING MEMBERS SHALL BE SPACED A MIN. OF 6" FROM HORIZ. PIPING OR DUCTWORK THAT IS NOT PROVIDED w/ BRACING RESTRAINTS FOR HORIZ. FORCES. MAIN RUNNER CROSS RUNNER (2) MIN. #10 S.M.S. ALLOW GAP FOR INSTALLATION OF CLG. TILE 2" MAX. TYP. NOTCH TO STRADDLE CROSS RUNNER H A9.2 L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 3/2/2023 4:30:01 PM A9.2 CEILING DETAILS 03.03.23 PERMIT SUBMITTAL Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 1/4" = 1'-0"A TYP. ACOUSTIC CEILING GRID 3" = 1'-0"B WALL CONDITION @ ATTACHED END 3" = 1'-0"C WALL CONDITION @ UNATTACHED END 3" = 1'-0" E SUSPENDED GYP. BD. CEILING 3" = 1'-0"G SPLAYED SEISMIC BRACING WIRE ATTACH. 3" = 1'-0"F VERT. HANGER WIRE ATTACH. 3" = 1'-0"H COMPRESSION POST TO STRUCT. 3" = 1'-0"D TYP. LATERAL FORCE BRACING 800 W Santa Ana Blvd. - 10111445404/06/23 ALIGN ADJACENT FINISH SURFACES CENTERLINE DESIGNATION FINISH CODE - REF. LEGEND THIS SHEETP1 CARPET C1 - TO BE DETERMINED BASE B1 - TO BE DETERMINED QUARTZ Q1 - TO BE DETERMINED PLASTIC LAMINATE PL1 - WILSONART HIGH PRESSURE LAMINATE; COLOR: FAWN CYPRESS #8208K-16 PL2 - WILSONART HIGH PRESSURE LAMINATE; COLOR: WHITE PAINT P1 - FIELD; TO BE DETERMINED P2 - ACCENT; TO BE DETERMINED WOOD STAIN ST1 - TO BE DETERMINED CEILING TILES CT1 - TO MATCH (E) PL1 Q1 B1 B A10.1 2' - 1 0 " P1 PL1 PL2 TYP. B A10.1 D A10.1 Q1 PL1 Q1 PL1 PL1 Q1 C A10.1 F A6.1 B1B1 Q1 PL2 PL2 B1 REMOVABLE WIRING ACCESS PANEL QUARTZ COUNTER TOP 4" 2' - 0 " 4" 1' - 11 1/2"10" 3' - 3" 2' - 1 0 " 4"4" 1' - 4 " O P E N I N G OPEN CHASE 1/4" RADIUS, TYP. OF ALL EDGES 3/4" PLYWOOD ov/ 2x6 D.F. STUDS, EA. SIDE B1 PL1 B1 PL1 Q1 RUBBER BASE RUBBER BASE TELLERS BRANCH 2 1/2" DIA. STAINLESS STEEL GROMMET - REF. NOTATION PLAN FOR LOCATIONS FINISH FLOOR PL1 REMOVABLE WIRING ACCESS PANEL QUARTZ COUNTER TOP 4" 2' - 3 " 4" 3' - 5 " 4" 1' - 7 " O P E N I N G OPEN CHASE 1/4" RADIUS, TYP. OF ALL EXPOSED QUARTZ EDGES 3/4" PLYWOOD ov/ 2x6 D.F. STUDS, EA. SIDE B1 PL1 B1 PL1 Q1 RUBBER BASE RUBBER BASE TELLERS BRANCH 2 1/2" DIA. STAINLESS STEEL GROMMET - REF. NOTATION PLAN FOR LOCATIONS FINISH FLOOR 3' - 1 1 " 4" 2" 4" EQ EQ 1' - 11 1/2"9 1/2" PL1 Q1 PL1 PL1 PL1 Q1 B1 P1 PL1 Q1 PL1 PL1PL1PL1 PL1 PL1 B1 B1 PL1PL1 1' - 3" B1 1' - 3" 1" OVERHANG 1" OVERHANG 1" OVERHANG 05.02 05.02 PL1 PL1 PL1 PL1 Q1 Q1 Q1 B1 B1 B1 QUARTZ COUNTER TOP 3' - 5 " 4" OPEN CHASE 1/4" RADIUS, TYP. OF ALL EXPOSED QUARTZ EDGES 3/4" PLYWOOD ov/ 2x6 D.F. STUDS, EA. SIDE PL1 Q1 TELLERS BRANCH 3' - 1 1 " 4" 2" 4" EQ EQ 1' - 11 1/2" 9 1/2" Q1 PL1 2x6 BLOCKING w/ #14 x 2-1/2" WD. SCREWS @ 8" O.C. (TYP.) , PLUS ONE #14 SCREW @ EA. CORNER - TYP. @ ALL CORNERS 1 3/4" LEG STAPLE @ 8" O.C. 2x OR 3/4" PLYWOOD #14 x 3-1/2" FLAT HEAD WD. SCREWS AT 16" O.C. CONT 2x4 w/ 1/4" WEDGE ANCHORS @ 24" O.C. DRAWER BASE CABINET ADJUSTABLE SHELVES -TYP. 3" 4" 1' - 10" QUARTZ COUNTER TOP 4"4" 4' - 7 " 1/4" RADIUS, TYP. OF ALL EXPOSED QUARTZ EDGES 3/4" PLYWOOD ov/ 2x6 D.F. STUDS, EA. SIDE B1 PL2 B1 Q1 RUBBER BASE RUBBER BASE TELLERS BRANCH FINISH FLOOR PL1 PL1 4" 4" 2' - 5 1/2" 4" 3' - 3" PRODUCT & MATERIAL REQUIREMENTS FOR INDOOR POLLUTANT CONTROL 1. ALL MATERIALS, ADHESIVES, COATINGS, AND SEALANTS SHALL COMPLY WITH V.O.C. LIMITATIONS SET FORTH BY THE LOCAL AIR POLLUTION CONTROL DISTRICT OR CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 11 (CALGREEN BUILDING STANDARDS), WHICHEVER IS MORE RESTRICTIVE. 2. ALL CARPET MATERIALS SHALL MEET THE TESTING AND PRODUCT REQUIREMENTS OF THE CARPET & RUG INSTITUTE’S GREEN LABEL PLUS PROGRAM OR EQUIVALENT CRITERIA SET FORTH IN CALIFORNIA CALGREEN BUILDING STANDARDS. 3. A MINIMUM OF 50% OF RESILIENT FLOORING SHALL COMPLY WITH THE V.O.C. EMISSION LIMITS DEFINED IN 2009 COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CHPS) CRITERIA AND LISTED ON ITS LOW-EMITTING MATERIALS LIST OR CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE FLOORSCORE PROGRAM. 4. ALL HARDWOOD COMPOSITE WOOD PRODUCTS (PLYWOOD, PARTICLEBOARD, AND MEDIUM DENSITY FIBERBOARD) SHALL MEET THE MAXIMUM FORMALDEHYDE EMISSIONS LIMITATIONS AS SPECIFIED IN ARB’S AIR TOXIC CONTROL MEASURE FOR COMPOSITE WOOD (17 CCR 93120 ET SEQ.) BY THE DATES SPECIFIED IN THOSE SECTIONS. 5. ARCHITECT HAS MADE EVERY REASONABLE ATTEMPT TO CONFIRM THAT PRODUCTS SPECIFIED IN THESE DOCUMENTS COMPLY WITH ABOVE-LISTED REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE SUBCONTRACTOR, VENDOR, AND/OR MANUFACTURER TO NOTIFY THE ARCHITECT THROUGH THE GENERAL CONTRACTOR OF ANY NON-COMPLIANT PRODUCT OR MATERIAL SPECIFIED BY THE ARCHITECT PRIOR TO BID DUE DATE. 6. CONTRACTOR SHALL PROVIDE PRODUCT/MATERIAL COMPLIANCE DOCUMENTATION WITH SUBMITTAL DOCUMENTS AS REQUIRED BY SPECIFICATION SECTION 013323. CONTRACTOR SHALL SUBMIT COMPLIANCE DOCUMENTATION TO THE JURISDICTION HAVING AUTHORITY UPON ACCEPTANCE BY ARCHITECT. L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 3/2/2023 4:30:01 PM A10.1 CASEWORK ELEVATIONS + DETAILS 03.03.23 PERMIT SUBMITTAL Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 LEGEND FINISHES LEGEND 3/8" = 1'-0" 3 STANDING COUNTER FROM LOBBY 3/8" = 1'-0"1 ACCESSIBLE COUNTER FROM LOBBY 1 1/2" = 1'-0"C ACCESSIBLE TELLER COUNTER 1 1/2" = 1'-0"B STANDING TELLER COUNTER 3/8" = 1'-0"4 STANDING COUNTER FROM TELLERS 3/8" = 1'-0"2 ACCESSIBLE COUNTER FROM TELLERS 1 1/2" = 1'-0" A STANDING TELLER COUNTER w/ CABINET 1 1/2" = 1'-0"D TELLER COUNTER @ TCR KEYNOTES 05.02 CASH DRAWER TO BE OWNER PROVIDED, CONTRACTOR INSTALLED NO. NAME FLOOR BASE WALL CEILING COMMENTS 100 OPEN OFFICE C1 B1 P1 CT1 101 BRANCH C1 B1 P1 CT1 102 OFFICE C1 B1 P1 CT1 103 TELLERS C1 B1 P1 / PL1 / PL2 CT1 ROOM FINISH SCHEDULE 800 W Santa Ana Blvd. - 10111445404/06/23 1 2 3 4 5 6 7 A B C AA OPEN OFFICE 100 BRANCH 101 VAULT 104 DATA 105 ELEC. 106 JAN. 109 STOR. 110 KITCHEN 111 TRAINING 112 BOARD ROOM 113 OFFICE 114 CEO OFFICE 115 OFFICE 116 QUIET ROOM 117 OPEN OFFICE 118 TOILET 108 TOILET 107 TELLERS 103 OFFICE 102 PANEL B PANEL A (E) (E) (E) REROUTE TO (E) PANEL B REROUTE TO (E) PANEL B PANEL B PANEL B PANEL B 1 2 3 4 5 6 7 A B C AA OPEN OFFICE 100 VAULT 104 DATA 105 ELEC. 106 JAN. 109 STOR. 110 KITCHEN 111 TRAINING 112 BOARD ROOM 113 OFFICE 114 CEO OFFICE 115 OFFICE 116 QUIET ROOM 117 OPEN OFFICE 118 TOILET 108 TOILET 107 BRANCH 101 TELLERS 103 OFFICE 102 L1 PANEL A PANEL A PANEL A PANEL A PANEL A PANEL B PANEL A L1 L1 L1 L1L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1L1 L1 L1 L1 L1 L1 L1 LIGHT FIXTURE - SEE SCHEDULE SINGLE GANG SWITCH w/ OCCUPANCY SENSOR 20A DUPLEX RECEPTACLE DATA OUTLET POWER POLE ELECTRICAL PANEL 2x4 RECESSED LIGHT FIXTURE CEILING MOUNTED ILLUMINATED EXIT SIGN w/ SINGLE FACE 1. ALL DIMENSIONS ARE TO FACE OF FINISH, U.O.N. 2. GANG DEVICES WHERE POSSIBLE 3. ALL SWITCH AND RECEPTACLE FACEPLATES TO BE WHITE FINISH 4. ALL LIGHTING SWITCHES SHALL BE MOUNTED WITH TOP OF SWITCH AT 48" A.F.F. LUMINAIRE SCHEDULE - MANUFACTURER NO. MODEL - L1 2'x4' LED TROFFER DESCRIPTION LUMENS / FT - FINISH WHITE QTY. 47 OTHER FEATURES DIMMING, OCCUPANCY SENSOR L ROFIEFAOT C NO. C 30857 REN. 3−31−23ATS ICE L AIN TC TEI ADNSE HCR MELANIE A .VIEUX Copyright WMB, Inc. DATE PURPOSE PUBLISH HISTORY: No. 2000 L Street Suite 125 Sacramento, CA 95811 T 209.944.9110 F 209.944.5711 www.wmbarchitects.com 5757 Pacific Avenue Suite 226 Stockton, CA 95207 WMB Project No. 3/2/2023 4:30:02 PM E1.1 ELECTRICAL LIGHTING + POWER PLAN 03.03.23 PERMIT SUBMITTAL Santa Ana Federal Credit Union Tenant Improvement 23-014 800 W Santa Ana Blvd Santa Ana, CA 92701 1/8" = 1'-0" POWER PLAN 1/8" = 1'-0" LIGHTING PLAN LEGEND GENERAL NOTES 800 W Santa Ana Blvd. - 10111445404/06/23 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments ·Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. ·Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2.Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5.Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6.Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7.Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8.Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9.Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10.Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM Melanie Vieux Digitally signed by Melanie Vieux DN: C=US, E=mv@wmbarchitects.com, O=WMB Architects, CN=Melanie Vieux Reason: I have reviewed this document Date: 2023.03.28 11:17:42-07'00' Melanie Vieux Digitally signed by Melanie Vieux DN: C=US, E=mv@wmbarchitects.com, O=WMB Architects, CN=Melanie Vieux Reason: I have reviewed this document Date: 2023.03.28 11:17:52-07'00' Melanie Vieux Digitally signed by Melanie Vieux DN: C=US, E=mv@wmbarchitects.com, O=WMB Architects, CN=Melanie Vieux Reason: I have reviewed this document Date: 2023.03.28 11:18:03-07'00' 800 W Santa Ana Blvd. - 10111445404/06/23 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 800 W Santa Ana Blvd. - 10111445404/06/23