Loading...
HomeMy WebLinkAbout700 E Alton Ave - Plan262' - 9" 1 4 8 ' - 7 " 138' - 5" 4' - 0" 120' - 4" 6' - 0 " 1 3 6 ' - 9 " 5' - 1 1 " 1 4 8 ' - 7 " 85 ' - 6 " 57 ' - 3 " S S T A N D A R D A V E E ALTON AVE 4 FOOT FIRE ACCESS TYP 4 F O O T F I R E A C C E S S ROOF ACCESS AC DICSONNECT FOR UTILITY OPERATION MAIN SERVICE ELECTRICAL AREA (OUTSIDE) PV SUB PANEL INVERTERS (6 TOTAL)35' - 7" 98 ' - 9 " 107' - 6" 64 ' - 6 " NOTE: OBSTRUCTIONS HAVE BEEN REMOVED AND THERE SHOULD BE NOTHING INTERFERING WITH THE SOLAR ARRAYS 1 1 To scale on 24x36 paper X___________________________ Confidentiality Statement: 5/2/2023 1:24:43 PM Site Plan FO S T E R P R I N T I N G C o 70 0 E A l t o n A v e Sa n t a A n a C A , 9 2 7 0 5 A101 This drawing is the property of RENEWABLE ENERGY PARTNERS. This information is confidential and is to be used only in connection with work described by RENEWABLE ENERGY PARTNERS. No part is to be discolosed to others without written permission from RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS LIC # 989857 EXP: 01/31/2024 RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS www.RENEWEPI.com 855-519-6633 170 MAPLE ST, STE 105 CORONA, CA 92881 1/16" = 1'-0"2 Site Layout with Aerial View Array Name Tilt° Azimuth Module Count Array Name 180 843 843 No . De sc r i p t i o n Da t e 1 A H J C o r r e c tio n s 5- 2 - 23 All equipment on the roof is screened by the parapet. All equipment on the exterior wall is screened from view by existing customer fencing/gate. 700 E Alton Ave - 101114289 & 2017906306/06/23 DRAWING INDEX C-1.0 COVER SHEET M-1.0 SITE PLAN & PROJECT SUMMARY M-2.0 ROOF PLAN (LAYOUT) M-3.0 LOAD REPORT M-4.0 BALLAST PLAN MECHANICAL PLAN SET BY: KB RACKING INC. 1050 KING ST. W, SUITE 03A104 TORONTO, ON M6K 0C7 EN G I N E E R ' S S E A L DRAWING NO. CL I E N T : PR O J E C T : PROVIDER 1050 KING ST. W, SUITE 03A104 TORONTO, ONTARIO M6K 0C7 CANADA TOLL - FREE TEL: 1.888.661.3204 LOCAL TEL: 416 532 2500 EMAIL: info@kbracking.com WWW.KBRACKING.COM DRAWN BY: CHECKED BY: VERSION: DR A W I N G T I T L E : PROJECT NO.: DATE: SHEET: OF NOTE: 843 Modules (Canadian 540W) DC Output: 455.22 kW (DC) EkonoRack L: 5 Degree Tilt Row Spacing: 4.59' Inter-Row Spacing: 0.88' Setback from edge: 4' - 2023/02/22 1 C-1.0 K.P.-3 CO V E R P A G E Fo s t e r P r i n t i n g RE P R e n e w 70 0 E a s t A l t o n 14 Sa n t a A n a . C A . 9 2 7 0 5 Foster Printing - 455.2 kW (dc) 700 East Alton, Santa Ana. CA. 92705 700 E Alton Ave - 101114289 & 2017906306/06/23 I:1, S:1 M:18, C:- I:1, S:1 M:18, C:+ I:1, S:2 M:18, C:- I:1, S:2 M:18, C:+ I:1, S:3 M:18, C:- I:1, S:3 M:18, C:+ I:1, S:4 M:18, C:- I:1, S:4 M:18, C:+ I:1, S:5 M:17, C:- I:1, S:5 M:17, C:+ I:1, S:8 M:17, C:- I:1, S:8 M:17, C:+ I:1, S:7 M:17, C:- I:1, S:7 M:17, C:+ I:2, S:1 M:18, C:- I:2, S:1 M:18, C:+ I:2, S:2 M:18, C:- I:2, S:2 M:18, C:+ I:2, S:3 M:18, C:- I:2, S:3 M:18, C:+ I:1, S:6 M:17, C:- I:1, S:6 M:17, C:+ I:2, S:3 M:18, C:- I:2, S:5 M:17, C:+ I:2, S:5 M:17, C:- I:2, S:6 M:17, C:+ I:2, S:6 M:17, C:- I:2, S:7 M:17, C:+ I:2, S:7 M:17, C:- I:2, S:8 M:17, C:+ I:2, S:8 M:17, C:- I:2, S:4 M:18, C:+ I:3, S:1 M:18, C:+ I:3, S:1 M:18, C:- I:3, S:2 M:18, C:+ I:3, S:2 M:18, C:- I:3, S:3 M:18, C:+ I:3, S:3 M:18, C:- I:3, S:4 M:18, C:+ I:3, S:4 M:18, C:- I:3, S:5 M:17, C:+ I:3, S:5 M:17, C:- I:3, S:6 M:17, C:+ I:3, S:6 M:17, C:- I:3, S:7 M:17, C:+ I:3, S:7 M:17, C:- I:3, S:8 M:17, C:+ I:3, S:8 M:17, C:- I:4, S:1 M:18, C:+ I:4, S:1 M:18, C:- I:4, S:2 M:18, C:+ I:4, S:2 M:18, C:- I:4, S:3 M:18, C:+ I:4, S:3 M:18, C:- I:4, S:4 M:18, C:+ I:4, S:4 M:18, C:- I:4, S:5 M:17, C:+ I:4, S:5 M:17, C:- I:4, S:6 M:17, C:+ I:4, S:6 M:17, C:- I:4, S:7 M:17, C:+ I:4, S:7 M:17, C:- I:4, S:8 M:17, C:+ I:4, S:8 M:17, C:- I:5, S:1 M:18, C:+ I:5, S:1 M:18, C:- I:5, S:2 M:18, C:+ I:5, S:2 M:18, C:- I:5, S:3 M:18, C:+ I:5, S:3 M:18, C:- I:5, S:4 M:18, C:+ I:5, S:4 M:18, C:- I:5, S:5 M:17, C:+ I:5, S:5 M:17, C:- I:5, S:6 M:17, C:+ I:5, S:6 M:17, C:- I:5, S:7 M:17, C:+ I:5, S:7 M:17, C:- I:5, S:8 M:17, C:+ I:5, S:8 M:17, C:- I:6, S:8 M:17, C:+ I:6, S:8 M:17, C:- I:6, S:1 M:18, C:+ I:6, S:1 M:18, C:- I:6, S:2 M:18, C:+ I:6, S:2 M:18, C:- I:6, S:3 M:18, C:+ I:6, S:3 M:18, C:- I:6, S:4 M:18, C:+ I:6, S:4 M:18, C:- I:6, S:5 M:18, C:+ I:6, S:5 M:18, C:- I:6, S:6 M:18, C:+ I:6, S:6 M:18, C:- I:6, S:7 M:18, C:+ I:6, S:7 M:18, C:- 10-24 SS BOLT TORQUE TO 18 FT-LBS 10-24 SS NUT /W STAR WASHER RAIL FRAME ILSCO #4 LAY IN LUG TINNED STAR WASHER REPRESENTATIVE CONDUCTORS CONDUIT COMPRESSION FITTING LOCK NUT ENCLOSURE WALL CONTINUOUS GROUND STRIP INSULATION AT LUG GROUND BUSHING WITH LAY-IN LUG JUNCTION BOX CONDUIT PYRAMID BLOCK ROOF DECK ROOFING ROOF FRAMING BEYOND FASTENED AT LEAST EVERY (10'-0")OR OTHER TUBING TERMINATION FASTENED (3'-0") FROM JUNCTION BOX, COMIBNER PYRAMID BLOCK (3 . 5 " ) AC DICSONNECT FOR UTILITY OPERATION MAIN SERVICE ELECTRICAL AREA (OUTSIDE) PV SUB PANEL INVERTERS (6 TOTAL) 1 To scale on 24x36 paper X___________________________ Confidentiality Statement: 5/2/2023 1:24:44 PM Electrical Layout FO S T E R P R I N T I N G C o 70 0 E A l t o n A v e Sa n t a A n a C A , 9 2 7 0 5 E101 This drawing is the property of RENEWABLE ENERGY PARTNERS. This information is confidential and is to be used only in connection with work described by RENEWABLE ENERGY PARTNERS. No part is to be discolosed to others without written permission from RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS LIC # 989857 EXP: 01/31/2024 RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS www.RENEWEPI.com 855-519-6633 170 MAPLE ST, STE 105 CORONA, CA 92881 6" = 1'-0"2 Detail Grounding Lay-in Lug3 6" = 1'-0"3 Detail Grounding Conduit Body4 1/2" = 1'-0"4 Detail Conduit Runs on Roof 3/32" = 1'-0"1 Electrical Layout Array Name Tilt° Azimuth Module Count Array Name 180 843 843 BALLAST ARRAY 5 180 843 No . De sc r i p t i o n Da t e 1 A H J C o r r e c tio n s 5- 2 - 23 I: #, S: # M: #, C: +/- KEY: STRING # INVERTER # QTY MODULES CHARGE 700 E Alton Ave - 101114289 & 2017906306/06/23 1.3 (1) #10 AWG CU THWN-2 EGC (16) #8 AWG CU PV WIRE FILL: 1.2515 IN^2 2" EMT ON STRUCTURES, 37% FILL DISTANCE: 300 FT, 0.87% VDROP 1.2 (1) #6 AWG CU SOLID CU EGC (2) #10 AWG CU PV WIRE DISTANCE: 100 FT, 0.46% VDROP 1.1 (1) #6 AWG CU SOLID CU EGC (2) #10 AWG CU PV WIRE DISTANCE: 1 FT, 0% VDROP 1.4 (1) #8 AWG CU THWN-2 EGC (1) #8 AWG CU THWN-2 NEUT (3) #2 AWG CU THWN-2 FILL: 0.4206 IN^2 1.25" EMT ON STRUCTURES, 28% FILL DISTANCE: 25 FT, 0.14% VDROP 1.71 (1) #1/O AWG CU THWN-2 EGC (1) #350 MCM CU THWN-2 NEUT (3) #350 MCM CU THWN-2 (2) PARALLEL RUNS (2) CONDUITS, IN EACH: FILL: 2.253 IN^2 2.5" EMT ON STRUCTURES, 38% FILL DISTANCE: 25 FT, 0.09% VDROP 1.81 (1) #1/O AWG CU THWN-2 EGC (1) #350 MCM CU THWN-2 NEUT (3) #350 MCM CU THWN-2 (2) PARALLEL RUNS (2) CONDUITS, IN EACH: FILL: 2.253 IN^2 2.5" EMT ON STRUCTURES, 38% FILL DISTANCE: 10 FT, 0.03% VDROP 1.82 (1) #2/O AWG AL THWN-2 EGC (1) #500 MCM AL THWN-2 NEUT (3) #500 MCM AL THWN-2 (2) PARALLEL RUNS (2) CONDUITS, IN EACH: FILL: 3.0515 IN^2 3" EMT ON STRUCTURES, 34% FILL DISTANCE: 10 FT, 0.04% VDROP 1.72 (1) #2/O AWG AL THWN-2 EGC (1) #500 MCM AL THWN-2 NEUT (3) #500 MCM AL THWN-2 (2) PARALLEL RUNS (2) CONDUITS, IN EACH: FILL: 3.0515 IN^2 3" EMT ON STRUCTURES, 34% FILL DISTANCE: 25 FT, 0.1% VDROP NOTES: 1. PROVIDE CONTINUOUS PATH FOR GROUND CONDUCTOR FROM THE INVERTER TO THE EXISTING MAIN SERVICE SWITCHBOARD GROUND BUS. GROUNDING ELECTRODE CONDUCTOR TO SERVE AS EQUIPMENT GROUND. PROVIDE LAY-IN LUGS TO BOND ALL EQUIPMENT ALONG THIS PATH TO THE GROUNDING ELECTRODE CONDUCTOR TO ALLOW FOR CONTINUOUS RUN. KEY PANELS PER STRING STRINGS PER INPUT ARRAY TUSTIN MCAF: COLD DESIGN TEMP = 2°C HOT DESIGN TEMP = 31°C 5 60.0 JBOX TYP MAX VOLTAGE DROP MODULE TO RSD EQUIPMENT = 0.00% RSD EQUIPMENT TO J-BOX = 0.46% J-BOX TO INVERTER = 0.87% INVERTER TO PV SUB PANEL = 0.19% PV SUB PANEL TO AC DISCONNECT = 0.10% AC DISCONNECT TO MAIN SERVICE = 0.04% TOTAL = 1.66% MAX STRING VOLTAGE = 19 MODULES PER STRING X (49.2 Voc + (-0.26%/°C X (2°C COLDEST - 25°C STC) X 49.2 Voc) = 991Voc < 1000Vdc OK X1 TO INPUTS 1-418 X1 TO INPUTS 5-818 TIGO TS4-A-2F MODUEL LEVEL RAPID SHUTDOWN EQUIPMENT PER STRINGNOTE: ALL PV WIRE TO BE A MINIMUM OF 1000Vdc RATED G G INV INTEGRATED DC DISCONNECT, 1000VDC 2 INPUTS PER MPPT INVERTER NUMBER INVERTER SIZE (kW) SUNGROW, SG60CX-US [480V] 277/480V, 3PH, 4W, 60.0 kW, 6 MPPT 6 MPPT TOTAL MAX OUTPUT CURRENT 72.2A INTEGRATED AFCI TRANSFORMERLESS UTILITY INTERACTIVE INTEGRATED AC DISCONNECT X 60.0 G G INV (N) 600A FUSED AC DISCONNECT FOR UTILITY OPERATION 600VAC, 600A FUSES, 3P, NEMA 3R 600A (N) SOLAR ONLY SUB PANEL (SUB 103), 600A 277/480V, 3PH, 4W, MLO, NEMA 3R, 42kAIC 6 60.0 JBOX TYP TIGO TS4-A-2F MODUEL LEVEL RAPID SHUTDOWN EQUIPMENT G G INV INV 1 - 60 kW STRINGS 1-8 140 MODULES 1 60.0 JBOX TYP TIGO TS4-A-2F MODUEL LEVEL RAPID SHUTDOWN EQUIPMENT 18 X 2 TO (MPPT 1)18 G G INV SYSTEM 1 PROJECT TOTAL: SYSTEM SIZE: 455.220 kW DC, 422.677 kW ACcec PANEL SPECS: (843) CSI SOLAR CO., LTD 540W SOLAR MODULES CS6W-540MB-AG MODULE AMPERAGE: 13.08 Imp, 13.90A Isc MODULE VOLTAGE: 41.3 Vmp, 49.2 Voc TEMP. COEFFICIENT OF Voc: -0.26%/°C PTC RATING: 508 W STC RATING: 540 W INVERTER SPECS: (6) SUNGROW 60KW INVERTER SG60CX-US [480V] CEC EFF: 98.7% RAPID SHUTDOWN SPECS: (432) TIGO TS4-A-2F VOLTAGE RANGE: 16-90V MAX CURRENT: 15A MAX POWER: 1000W SEE SPEC SHEET FOR ELECTRICAL PARAMETERS AND WARRANTY INFO 18 X 2 TO (MPPT 2) 18 17 X 1 TO (MPPT 3-6)17 2 60.0 JBOX TYP TIGO TS4-A-2F MODUEL LEVEL RAPID SHUTDOWN EQUIPMENT G G INV ROOF ARRAY - (843) 450 WATTS INVERTERS 1-5 (60KW) (140) MODULES STRINGS 1-4: 18 MODULES STRINGS 5-8: 17 MODULES (72) TIGO OPTIMIZER RAPID SHUTDOWN EQUIPMENT INVERTER 6 (60KW) (143) MODULES STRINGS 1-7: 18 MODULES STRING 8: 17 MODULES (72) TIGO OPTIMIZER RAPID SHUTDOWN EQUIPMENT MISC FACILITY LOADS (E) 3000A MAIN SERVICE PANEL 480Y/277V, 3PH, 4W, 65kAIC (E) 3000A MAIN GRD (E) GROUND ROD STRING CURRENT: 13.08A IMP, 13.90A ISC STRING VOLTAGE: 17 MODULE STRINGS: 702.1VMP, 836.4VOC 18 MODULE STRINGS: 743.4VMP, 885.6VOC 100A/3P INV 1 OU T S I D E B U I L D I N G EL E C T R I C A L A R E A 100A/3P INV 6 3 60.0 JBOX TYP TIGO TS4-A-2F MODUEL LEVEL RAPID SHUTDOWN EQUIPMENT G G INV 4 60.0 JBOX TYP TIGO TS4-A-2F MODUEL LEVEL RAPID SHUTDOWN EQUIPMENT G G INV 100A/3P INV 4 -OR--OR- X1X2 X3 SYSTEM AVAILABLE FAULT CURRENT INV 2 - 60 kW STRINGS 1-8 140 MODULES 18 X 2 TO (MPPT 1)18 18 X 2 TO (MPPT 2)18 17 X 1 TO (MPPT 3-6)17 INV 3 - 60 kW STRINGS 1-8 140 MODULES 18 X 2 TO (MPPT 1)18 18 X 2 TO (MPPT 2)18 17 X 1 TO (MPPT 3-6)17 INV 4 - 60 kW STRINGS 1-8 140 MODULES 18 X 2 TO (MPPT 1)18 18 X 2 TO (MPPT 2)18 17 X 1 TO (MPPT 3-6)17 INV 5 - 60 kW STRINGS 1-8 140 MODULES 18 X 2 TO (MPPT 1)18 18 X 2 TO (MPPT 2)18 17 X 1 TO (MPPT 3-6)17 INV 6 - 60 kW STRINGS 1-8 143 MODULES 18 X 2 TO (MPPT 1)18 18 X 2 TO (MPPT 2)18 17 X 1 TO (MPPT 3-6)17 100A/3P INV 1 100A/3P INV 1 100A/3P INV 4 ON R O O F M UTILITY CUSTOMER (E) 3000A MAIN SERVICE FROM UTILITY (UNDERGROUND SERVICE) METER PULL SECTION 12" = 1'-0"1 Single Line Diagram System 1 To scale on 24x36 paper X___________________________ Confidentiality Statement: 2/27/2023 3:27:39 PM Single Line Diagram FO S T E R P R I N T I N G C o 70 0 E A l t o n A v e Sa n t a A n a C A , 9 2 7 0 5 E201 This drawing is the property of RENEWABLE ENERGY PARTNERS. This information is confidential and is to be used only in connection with work described by RENEWABLE ENERGY PARTNERS. No part is to be discolosed to others without written permission from RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS LIC # 989857 EXP: 01/31/2024 RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS www.RENEWEPI.com 855-519-6633 170 MAPLE ST, STE 105 CORONA, CA 92881 WIRE RATING CHART 1 Pa r a l l e l R u n s Wi r e A m p R a t i n g Wi r e T e m p D e r a t e Wi r e C o n d u c t o r D e r a t e Derated Wire Rating <= Amps Max . . 1 40 0.96 1 1 X 40A X 0.96 X 1 = 38 >= 22 1 40 0.96 1 1 X 40A X 0.96 X 1 = 38 >= 22 1 55 0.96 0.5 1 X 55A X 0.96 X 0.5 = 26 >= 22 1 130 0.96 1 1 X 130A X 0.96 X 1 = 125 >= 90 2 350 0.96 1 2 X 350A X 0.96 X 1 = 672 >= 542 2 350 0.96 1 2 X 350A X 0.96 X 1 = 672 >= 542 2 350 0.96 1 2 X 350A X 0.96 X 1 = 672 >= 542 2 350 0.96 1 2 X 350A X 0.96 X 1 = 672 >= 542 VOLTAGE DROP CHART 1 Vd r o p A m p s I m p Vd r o p V m p Vd r o p D i s t a n c e Vd r o p P e r c e n t . . 13.08 702.1 1 0 13.08 702.1 100 0.46 13.08 702.1 300 0.87 72.2 480 25 0.14 433.2 480 25 0.09 433.2 480 25 0.1 433.2 480 10 0.03 433.2 480 10 0.04 TERMINATION... Te r m T e m p R a t i n g Term Amp Rating >=Amps Max . . 60 30 >=22 60 30 >=22 60 40 >=22 60 95 >=90 75 620 >=542 75 620 >=542 75 620 >=542 75 620 >=542 WIRING CHART 1 Ca l l o u t # Am p s I s c NE C M u l t Am p s M a x Pa r a l l e l R u n s Nu m b e r C o n d u c t o r s Si z e C o n d u c t o r Co n d u c t o r M a t l In s u l a t i o n C o n d u c t o r Si z e N e u t r a l Si z e G r o u n d Co n d u i t Q t y Wi r e T e m p R a t i n g Wi r e A m b T e m p Wi r e R o o f T e m p Wi r e T e m p T o t a l Co n d u c t o r s C u r r e n t C a r r y i n g . . 1.1 13.9 1.56 22 1 2 #10 AWG CU PV WIRE NA #6 AWG 1 90 31 0 31 2 1.2 13.9 1.56 22 1 2 #10 AWG CU PV WIRE NA #6 AWG 1 90 31 0 31 2 1.3 13.9 1.56 22 1 16 #8 AWG CU PV WIRE NA #10 AWG 1 90 31 0 31 16 1.4 72.2 1.25 90 1 3 #2 AWG CU THWN-2 #8 AWG #8 AWG 1 90 31 0 31 3 1.71 433.2 1.25 542 2 3 #350 MCM CU THWN-2 #350 MCM #1/O AWG 2 90 31 0 31 3 1.72 433.2 1.25 542 2 3 #500 MCM AL THWN-2 #500 MCM #2/O AWG 2 90 31 0 31 3 1.81 433.2 1.25 542 2 3 #350 MCM CU THWN-2 #350 MCM #1/O AWG 2 90 31 0 31 3 1.82 433.2 1.25 542 2 3 #500 MCM AL THWN-2 #500 MCM #2/O AWG 2 90 31 0 31 3 No . De s c r ip ti o n Da t e 700 E Alton Ave - 101114289 & 2017906306/06/23 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS SHOWN. DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES. "WARNING" PHOTOVOLTAIC ARRAY DISCONNECTION OF NEUTRAL OR GROUNDED CONDUCTORS MAY RESULT IN OVERVOLTAGE ON ARRAY OR INVERTER 6"X8" TYP - CEC 705.10 NOTES 1. ARTICLES 690 AND 705 MARKINGS SHOWN HEREON 2. ALL MARKINGS SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING B. RED BACKGROUND COLOR WITH WHITE TEXT AND LINE WORK UON C. ARIAL FONT 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT USING PERMANENT ADHESIVE, POP-RIVETS, OR SCREWS M JBOX OR COMBINER AC DISCONNECT 885.6V INVERTER WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! ORANGE WARNING AREA, 690.13(B) WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL ! ORANGE WARNING AREA, 110.27(C) WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! ORANGE WARNING AREA, 690.13(B) DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT PHOTOVOLTAIC 690.13(B) DC DISCONNECT MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) 690.53 WARNING: PHOTOVOLTAIC POWER SOURCE REFLECTIVE STICKER, 690.31(G)(3)(4) WARNING! DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM ORANGE WARNING AREA, 705.12(B)(3) PHOTOVOLTAIC AC DISCONNECT 690.13(B), 690.54 RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY The title “SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN” shall utilize capitalized characters with a minimum height of 9.5 mm (3⁄8 in.) in black on yellow background and the remaining characters shall be capitalized with a minimum height of 4.8 mm (3⁄16 in.) in black on white background. 690.56(C)(1)(a) PV ARRAY DC DISCONNECT 1 2 3 4 5 6 7 8 10 1 6 34 8 2 7 10 13.90A NA 5 480V 433.2A SOLAR SUB PANEL OR AC COMBINER (IF USED) 1 1 2 7 6 INVERTERS To scale on 24x36 paper X___________________________ Confidentiality Statement: 2/24/2023 7:36:38 PM Signage FO S T E R P R I N T I N G C o 70 0 E A l t o n A v e Sa n t a A n a C A , 9 2 7 0 5 E301 This drawing is the property of RENEWABLE ENERGY PARTNERS. This information is confidential and is to be used only in connection with work described by RENEWABLE ENERGY PARTNERS. No part is to be discolosed to others without written permission from RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS LIC # 989857 EXP: 01/31/2024 RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS www.RENEWEPI.com 855-519-6633 170 MAPLE ST, STE 105 CORONA, CA 92881 12" = 1'-0"2 Signage PV MAIN SERVICE PANEL AC DISCONNECT FOR UTILITY OPERATION E ALTON AVE S S T A N D A R D A V E No . De s c r ip ti o n Da t e 700 E Alton Ave - 101114289 & 2017906306/06/23 March 09, 2023 Samira Sanaee KB Racking 1050 King St. W., Suite 03A104 Toronto, Ontario M6K 0C7 Re: Foster Printing - PV Ballast 700 East Alton Ave. Santa Ana, CA 92705 EEI Proj. No.: 23-03-079 Samira, As requested, we have reviewed the solar array layout and ballasting requirement calculations prepared by KB Racking for the above-noted project. The purpose of our review is to verify the adequacy of the ballasting requirements specified by KB Racking to withstand the wind forces of the region noted above. Our analysis assumes that the product type for the solar array will be EkonoRack, by KB Racking, with array size, orientation, and panel information as specified on Sheet S-1 of the plans prepared by KB Racking. Design wind drag-force coefficients for the EkonoRack system were determined by Rowan Williams Davies & Irwin, Inc. (RWDI) in separate, third-party wind-tunnel testing and have been adapted for use in our analysis on this project. The attached structural calculations are based on RWDI’s testing results, the plans prepared by KB Racking, and the following design criteria: Design Criteria:  Building Jurisdiction: Santa Ana, CA  Applicable Codes: 2022 Cal. Building Code, ASCE 7-16  Basic Wind Speed: 95 mph, Risk Cat. II, Exposure B  Solar Modules: 89.21”x44.65” & 71.0lb for Canadian 540W Panels @ 5 degrees Concluding our review, we find that the solar array ballast requirements shown on the calculations provided by KB Racking are adequate to support the required loading of the above noted building jurisdiction. Eclipse Engineering, P.C. has reviewed the ballast requirements for the new solar array only, therefore, we do not take responsibility for any other portion of the structure, structural members not covered within this report, nor the integrity of the structure as a whole. Owner shall abide by ASCE 7-16 Section 13.6.12 for signage, roof markings, and allowable solar array movement in accordance with the supporting calculations. Sincerely, Eclipse Engineering, Inc. Brett Allen, P.E., Project Manager Enclosed: Supporting Calculations; Plan set by KB Racking 03/09/2023 Digitally signed by Scott Ratterman Date: 2023.03.09 13:38:00-08'00' 700 E Alton Ave - 101114289 & 2017906306/06/23 Table of Contents Content Page DETERMINATION OF REQUIRED MODULE BALLAST – BUILDING 1 3 – 4 DETERMINATION OF REQUIRED MODULE BALLAST – BUILDING 2 5 – 6 ASCE HAZARDS 7 – 8 SEISMIC CALC & REQUIRED DISPLACEMENT 9 ATTACHMENT(S): PLAN SET & CALCS BY KB RACKING FOR COMPARISON 10 – 23 700 E Alton Ave - 101114289 & 2017906306/06/23 Foster Printing 03/08/2023 Brett Allen, P.E. DETERMINE BALLAST REQUIREMENTS FOR EKONORACK SYSTEM BY KB RACKING-BUILDING 1 Project Information Project Name & Location -Foster Printing, 700 East Alton Ave, Santa Ana, CA 92705 KB Racking Project Number -- Building Code -2022 CBC, 2021 IBC, ASCE 7-16 Wind Loading - ASCE Standard - ASCE 7 Chapter 27 Directional Procedure 3 Second Wind Gust -V = 95 mph Risk Cat. II Importance Factor -I w = 1.00 ASD Conversion Factor -Ω = 0.6 Wind Exposure -Exposure = B Mean Roof Height -Hr = 23 ft 3-Second Gust-Speed Power Law Exponent -α = 7 Nominal Height of Atmospheric Boundary Layer -zg = 1200 ft Wind Directionality Factor -Table 26.6-1 Kd = 0.85 Velocity Exposure Coefficient -Table 26.10-1 Kz = 0.7 Topographic Factor -Section 26.8.2 Kzt = 1 Ground Elevation Factor -Section 26.9 Ke = 1.000 Velocity Pressure -27.3.2 qz = 8.14 psf Velocity Pressure w/o ASD Conversion -qz,LRFD = 13.75 psf Array Layout & Panel Information Solar Panel Length -lpanel = 89.210 in Solar Panel Length (Design) -lpaneld = 89.997 in Solar Panel Width -wpanel = 44.650 in Solar Panel Row Spacing -wspacing = 58.224 in Solar Panel Thickness -tpanel = 1.380 in Solar Panel Uplift Area -Aup = 27.631 ft2 Solar Panel Drag Area -Adrag = 3.263 ft2 Solar Panel Design Area -Apd = 36.389 ft2 Solar Panel Weight -Wpanel = 71.000 lb Panel Weight + Hardware -Wtotal = 75.852 lb Drag Force Coefficients Design Wind Pressures Note: drag force coefficients were provided in the wind tunnel test report prepared by RWDI Inc. "KB RACKING ROOF-MOUNTED PV RACKING SYSTEMS WIND PRESSURE STUDY", Report #1600846 and are the property of KB Racking. The following calculations contained within use the drag force coefficients determined by RWDI for the PV system by KB Racking installed at the tilt angle defined above. The drag force coefficients have been hidden from the calculations as they are the property of KB Racking. Note: design wind pressures are a function of the drag coefficients for the PV solar system by KB Racking determined in the above-referenced wind tunnel testing. Use of the drag coefficients or wind pressures shown below by others is not permitted for any other system. Eclipse Engineering have provided a review of the plans and calculations prepared by KB Racking for the above-noted project only. 3/23 700 E Alton Ave - 101114289 & 2017906306/06/23 Foster Printing 03/08/2023 Brett Allen, P.E. Required Ballast Per module (Uplift Loading) 1x1 Module 2x2 Module 3x3 Module North Corner 216.62 83.68 26.70 North Leading Edge 114.06 19.11 15.31 East & West Edges 163.44 83.68 26.70 Field 114.06 19.11 15.31 South Corner 163.44 83.68 26.70 South Leading Edge 114.06 19.11 15.31 1x1 Module 2x2 Module 3x3 Module North Corner 8.04 4.38 2.82 North Leading Edge 5.22 2.61 2.51 East & West Edges 6.58 4.38 2.82 Field 5.22 2.61 2.51 South Corner 6.58 4.38 2.82 South Leading Edge 5.22 2.61 2.51 Ballast in Pounds Ballast in Pounds / Sq Ft Note: ballast requirements determined from wind pressures above. Provided for review and comparison to the attached calculations prepared by KB Racking. 4/23 700 E Alton Ave - 101114289 & 2017906306/06/23 Foster Printing 03/08/2023 Brett Allen, P.E. DETERMINE BALLAST REQUIREMENTS FOR EKONORACK SYSTEM BY KB RACKING-BUILDING 2 Project Information Project Name & Location -Foster Printing, 700 East Alton Ave, Santa Ana, CA 92705 KB Racking Project Number -- Building Code -2022 CBC, 2021 IBC, ASCE 7-16 Wind Loading - ASCE Standard - ASCE 7 Chapter 27 Directional Procedure 3 Second Wind Gust -V = 95 mph Risk Cat. II Importance Factor -I w = 1.00 ASD Conversion Factor -Ω = 0.6 Wind Exposure -Exposure = B Mean Roof Height -Hr = 15 ft 3-Second Gust-Speed Power Law Exponent -α = 7 Nominal Height of Atmospheric Boundary Layer -zg = 1200 ft Wind Directionality Factor -Table 26.6-1 Kd = 0.85 Velocity Exposure Coefficient -Table 26.10-1 Kz = 0.7 Topographic Factor -Section 26.8.2 Kzt = 1 Ground Elevation Factor -Section 26.9 Ke = 1.000 Velocity Pressure -27.3.2 qz = 8.14 psf Velocity Pressure w/o ASD Conversion -qz,LRFD = 13.75 psf Array Layout & Panel Information Solar Panel Length -lpanel = 89.210 in Solar Panel Length (Design) -lpaneld = 89.997 in Solar Panel Width -wpanel = 44.650 in Solar Panel Row Spacing -wspacing = 58.224 in Solar Panel Thickness -tpanel = 1.380 in Solar Panel Uplift Area -Aup = 27.631 ft2 Solar Panel Drag Area -Adrag = 3.263 ft2 Solar Panel Design Area -Apd = 36.389 ft2 Solar Panel Weight -Wpanel = 71.000 lb Panel Weight + Hardware -Wtotal = 75.852 lb Drag Force Coefficients Design Wind Pressures Note: drag force coefficients were provided in the wind tunnel test report prepared by RWDI Inc. "KB RACKING ROOF-MOUNTED PV RACKING SYSTEMS WIND PRESSURE STUDY", Report #1600846 and are the property of KB Racking. The following calculations contained within use the drag force coefficients determined by RWDI for the PV system by KB Racking installed at the tilt angle defined above. The drag force coefficients have been hidden from the calculations as they are the property of KB Racking. Note: design wind pressures are a function of the drag coefficients for the PV solar system by KB Racking determined in the above-referenced wind tunnel testing. Use of the drag coefficients or wind pressures shown below by others is not permitted for any other system. Eclipse Engineering have provided a review of the plans and calculations prepared by KB Racking for the above-noted project only. 5/23 700 E Alton Ave - 101114289 & 2017906306/06/23 Foster Printing 03/08/2023 Brett Allen, P.E. Required Ballast Per module (Uplift Loading) 1x1 Module 2x2 Module 3x3 Module North Corner 133.06 38.10 0.11 North Leading Edge 76.08 0.11 0.11 East & West Edges 95.07 38.10 0.11 Field 76.08 0.11 0.11 South Corner 95.07 38.10 0.11 South Leading Edge 76.08 0.11 0.11 1x1 Module 2x2 Module 3x3 Module North Corner 5.74 3.13 2.09 North Leading Edge 4.18 2.09 2.09 East & West Edges 4.70 3.13 2.09 Field 4.18 2.09 2.09 South Corner 4.70 3.13 2.09 South Leading Edge 4.18 2.09 2.09 Ballast in Pounds Ballast in Pounds / Sq Ft Note: ballast requirements determined from wind pressures above. Provided for review and comparison to the attached calculations prepared by KB Racking. 6/23 700 E Alton Ave - 101114289 & 2017906306/06/23 ASCE 7 Hazards Report Address: 700 E Alton Ave Santa Ana, California 92705 Standard: ASCE/SEI 7-16 Latitude: 33.70442 Risk Category: II Longitude: -117.859181 Soil Class: D - Default (see Section 11.4.3) Elevation: 0 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source:ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed:Wed Mar 08 2023 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 3 https://asce7hazardtool.online/ Wed Mar 08 2023 7/23 700 E Alton Ave - 101114289 & 2017906306/06/23 SS :1.27 S1 :0.455 F a :1.2 F v :N/A SMS :1.524 SM1 :N/A SDS :1.016 SD1 :N/A T L :8 PGA :0.538 PGA M :0.646 F PGA :1.2 Ie :1 C v :1.354 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Wed Mar 08 2023 Page 2 of 3 https://asce7hazardtool.online/ Wed Mar 08 2023 8/23 700 E Alton Ave - 101114289 & 2017906306/06/23 Calcs By: BMA 3/9/2023 Calculate Seismic Force Per ASCE 7 Sec. 13.3.1 Spectral Acceleration, SDS=1.016 g Component Amplification, ap=1.00 Other mechanical component Component Importance, Ip=1.00 Number of solar panels =1 Component Weight, Wp-dead= 75.9 lb. Solar Panel + racking (1 panel) Component Response Mod. Factor, Rp= 1.50 Other mechanical component Attachment Height to base, z= 318.00 in. Conservative +6" stand height Average height to base, h= 312.00 in. Seismic Design Force, Fp= 62.4 lb. Ultimate Lateral seismic force 0.6*Wp = 45.5 lb. Minimum per ASCE 13.6.12 Max Req. Seismic Design Force, Fp-max= 123.3 lb. Fp-max = 1.6SDSIPWP Min Seismic Design Force, Fp-min= 23.1 lb. Fp-max = 0.3SDSIPWP Controlling Seismic Lateral Force, Fp= 62.4 lb. Vertical Seismic Force = +/-0.2SdsWp = 15.4 lb. < provided ballast, therefore okay Each PV panel shall have the below setback surrounding each PV panel without impact. A minimum 0.5 δmpv separation between adjacent panels. A minimum 2.0δmpv separation between panels and edge of roof. Per ASCE 13.6.12 δmpv = 1.90 ft. Min = 2.00 ft. Use = 2.00 ft. The owner is responsible for any and all signage that shall be provided delineating the area around the panels that must be kept free of obstructions. Electrical cables shall abide to ASCE Section 13.6.12, performed by others. The parapet of the main structure shall be able to resist an impact of 0.2*Sds*Wpdead per ASCE 13.6.12. To be designed by others. Displacement Requirements of Panels 9/23 700 E Alton Ave - 101114289 & 2017906306/06/23 10/23 700 E Alton Ave - 101114289 & 2017906306/06/23 11/23 700 E Alton Ave - 101114289 & 2017906306/06/23 12/23 700 E Alton Ave - 101114289 & 2017906306/06/23 13/23 700 E Alton Ave - 101114289 & 2017906306/06/23 14/23 700 E Alton Ave - 101114289 & 2017906306/06/23 15/23 700 E Alton Ave - 101114289 & 2017906306/06/23 16/23 700 E Alton Ave - 101114289 & 2017906306/06/23 17/23 700 E Alton Ave - 101114289 & 2017906306/06/23 18/23 700 E Alton Ave - 101114289 & 2017906306/06/23 19/23 700 E Alton Ave - 101114289 & 2017906306/06/23 20/23 700 E Alton Ave - 101114289 & 2017906306/06/23 21/23 700 E Alton Ave - 101114289 & 2017906306/06/23 22/23 700 E Alton Ave - 101114289 & 2017906306/06/23 23/23 700 E Alton Ave - 101114289 & 2017906306/06/23 SITE PLAN LOADING INFORMATION EN G I N E E R ' S S E A L DRAWING NO. CL I E N T : PR O J E C T : PROVIDER 1050 KING ST. W, SUITE 03A104 TORONTO, ONTARIO M6K 0C7 CANADA TOLL - FREE TEL: 1.888.661.3204 LOCAL TEL: 416 532 2500 EMAIL: info@kbracking.com WWW.KBRACKING.COM DRAWN BY: CHECKED BY: VERSION: DR A W I N G T I T L E : PROJECT NO.: DATE: SHEET: OF NOTE: 843 Modules (Canadian 540W) DC Output: 455.22 kW (DC) EkonoRack L: 5 Degree Tilt Row Spacing: 4.59' Inter-Row Spacing: 0.88' Setback from edge: 4' - 2023/02/22 2 M-1.0 K.P.-3 SI T E P L A N - P R O J E C T S U M M A R Y Fo s t e r P r i n t i n g RE P R e n e w 70 0 E a s t A l t o n 14 Sa n t a A n a . C A . 9 2 7 0 5 Project Information Client Name REP Renew Project Name Foster Printing Project Address 700 East Alton, Santa Ana. CA. 92705 Total Panel Count 843 Project Size (kW)455.2 System Panel Name Canadian 540W Panel Weight (lbs)71.0 Panel Length (in)89.21 Panel Width (in)44.65 Panel Thickness (in)1.38 Panel Power (W)540 Panel Cell Type 72 System Orientation Landscape System Tilt (deg)5 Racking Weight Per Panel (lbs)4.852 System Row Spacing (ft)4.593 Inter-Row Spacing (ft)0.876 Reinforcement NO Environment Exposure B Risk Category II Wind Speed (mph)95 qz (lb/ft²)13.8 Sea Level (ft)0-999 LB Factor 14.37 Wind Load Factor: w 0.6 Dead Load Factor: D 0.6 Closeness Factor 1.0 RoofType TPO Friction Coefficient 1.05 Setback (ft)4 Buildings Building Building Height (ft)Parapet (in) | Wl (ft) | Ws (ft) 1 23 18 | 267 | 152 2 15 0 | 86 | 25 Array Number of Panels Array Area (ft²) Area Reduction Factor Uplift Ballast (lbs) Drag Ballast (lbs) Additional Ballast per Panel Due to Drag (lbs) Total Ballast for Array (lbs)Average PSF 1 372 12814.07 0.1000 13935.26 0.00 0.00 13935.26 3.27 2 383 13192.98 0.1000 14147.40 0.00 0.00 14147.40 3.26 3 55 1894.55 0.1942 3005.46 0.00 0.00 3005.46 3.78 4 15 516.70 0.3367 722.85 166.35 0.00 722.85 3.62 5 18 620.04 0.3160 873.45 103.54 0.00 873.45 3.61 Total 843 Total Ballast Weight 32684.42 Total System Weight 96627.66 GENERAL NOTES: 1. THIS REPORT PROVIDES BALLAST AND LAYOUT INFORMATION FOR THE SOLAR SYSTEM. 2. SEE INSTALLATION DRAWINGS AND INSTALLATION LAYOUT FOR DIMENSIONS AND ARRAY INFORMATION. 3. BALLAST SYSTEM IS DESIGNED BASED ON THE FOLLOWING REFERENCES: 3.1. INTERNATIONAL BUILDING CODE (IBC) 2009 / 2012 / 2015 / 2018 3.2. CALIFORNIA BUILDING CODE (CBC) 2019 3.3. AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE): MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES 7-16 · Exposure Category (ASCE 7-16 Section 26.7.3) · Risk Category (ASCE 7-16 Table 1.5-1) · aw = factor on wind load (ASCE 7-16 Section 2.4.1.7.) · aD = factor on dead load (ASCE 7-16 Section 2.4.1.7.) · qz = Velocity Pressure (ASCE 7-16 Section 26.10.2) 3.4 KB RACKING ROOF-MOUNTED PV RACKING SYSTEMS WIND PRESSURE STUDY, RWDI #1300905, July 31,2020 *Ballast to Resist Uplift = (αw∙qz∙|GCp|uplift∙Auplift - αD∙M)/αD *Ballast to Resist Drag = [αw∙qz∙[(GCp)drag∙Adrag∙(1/fn)+|GCp|uplift∙Auplift] - αD∙M]/αD 4. A PROFESSIONAL STRUCTURAL ENGINEER LICENSED WHERE THE RACKING SYSTEM WILL BE INSTALLED IS REQUIRED TO APPROVE THE DESIGN. 5. THE STRUCTURAL ENGINEER OF THE BUILDING IS RESPONSIBLE TO CHECK THE ADEQUACY OF THE BUILDING'S STRUCTURAL CAPACITY TO SUPPORT THE LOADS INDICATED ON THIS DRAWING. 6. THE MOUNTING SYSTEM SHALL BE INSTALLED AS PER KB RACKING SPECIFICATIONS AND PROCEDURES. 7. INSTALL THE SPECIFIED PHOTOVOLTAIC MODULES ONLY. ANY CHANGES IN THE MODULE SIZE OR TYPE MUST BE NOTIFIED TO KB RACKING INC. 8. ANY CHANGES IN THE MOUNTING SYSTEM LAYOUT IS NOT PERMITTED UNLESS APPROVED BY KB RACKING INC. NOTE: AVERAGE PSF LOADS REPRESENT THE UNIFORMLY DISTRIBUTED LOAD IMPOSED BY THE RACKING INSTALLATION ON THE ROOF. AVERAGE LOADS SHOULD NOT BE USED FOR THE STRUCTURAL REVIEW OF THE SUPPORTING ROOF STRUCTURE WITHOUT CONSIDERATION FOR LOCALIZED PSF LOADS WHICH MAY BE MORE SIGNIFICANT. LOCALIZED PSF LOADS PER PANEL ARE ACCOMPANIED WITHIN THIS REPORT IN THE FOLLOWING PAGES. KB RACKING INC. HAS NO LIABILITY FOR THE USE OF THIS REPORT BY THE CUSTOMER. IF THERE ARE ANY QUESTIONS OR CONCERNS, PLEASE CONTACT KB RACKING INC. 700 E Alton Ave - 101114289 & 2017906306/06/23 Array 1 372 Panels Array 2 383 Panels Array 3 55 Panels Array 4 15 Panels Array 5 18 Panels LEGEND EkonoRack Support PV Panel EN G I N E E R ' S S E A L DRAWING NO. CL I E N T : PR O J E C T : PROVIDER 1050 KING ST. W, SUITE 03A104 TORONTO, ONTARIO M6K 0C7 CANADA TOLL - FREE TEL: 1.888.661.3204 LOCAL TEL: 416 532 2500 EMAIL: info@kbracking.com WWW.KBRACKING.COM DRAWN BY: CHECKED BY: VERSION: DR A W I N G T I T L E : PROJECT NO.: DATE: SHEET: OF NOTE: 843 Modules (Canadian 540W) DC Output: 455.22 kW (DC) EkonoRack L: 5 Degree Tilt Row Spacing: 4.59' Inter-Row Spacing: 0.88' Setback from edge: 4' - 2023/02/22 3 M-2.0 K.P.-3 RO O F P L A N Fo s t e r P r i n t i n g RE P R e n e w 70 0 E a s t A l t o n 14 Sa n t a A n a . C A . 9 2 7 0 5 Inverted Supports (6) 700 E Alton Ave - 101114289 & 2017906306/06/23 84 (4.6) 27 (3.0) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 84 (4.6) 84 (4.6) 15 (2.6) 15 (2.6) 19 (2.8) 84 (4.6) 27 (3.0) 15 (2.6) 19 (2.8) 153 (6.6) 84 (4.6) 19 (2.8) 19 (2.8) 84 (4.6) 84 (4.6) 19 (2.8) 19 (2.8) 67 (4.1) 67 (4.1) 19 (2.8) 84 (4.6) 84 (4.6) 19 (2.8) 19 (2.8) 19 (2.8) 67 (4.1) 67 (4.1) 19 (2.8) 19 (2.8) 67 (4.1) 84 (4.6) 84 (4.6) 19 (2.8) 67 (4.1) 19 (2.8) 15 (2.6) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 27 (3.0) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 84 (4.6) 84 (4.6) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 27 (3.0) 27 (3.0) 84 (4.6) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 84 (4.6) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 27 (3.0) 27 (3.0) 15 (2.6) 19 (2.8) 84 (4.6) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 27 (3.0) 15 (2.6) 19 (2.8) 84 (4.6) 27 (3.0) 84 (4.6) 84 (4.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 153 (6.6) 153 (6.6) 67 (4.1) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 27 (3.0) 84 (4.6) 84 (4.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 84 (4.6) 84 (4.6) 126 (5.9) 67 (4.1) 19 (2.8) 84 (4.6) 84 (4.6) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 153 (6.6) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 84 (4.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 199 (8.0) 84 (4.6) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 84 (4.6) 27 (3.0) 27 (3.0) 15 (2.6) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 153 (6.6) 84 (4.6) 84 (4.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 15 (2.6) 84 (4.6) 19 (2.8) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 15 (2.6) 84 (4.6) 19 (2.8) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 15 (2.6) 19 (2.8) 67 (4.1) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 84 (4.6) 19 (2.8) 15 (2.6) 19 (2.8) 15 (2.6) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 27 (3.0) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 126 (5.9) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 84 (4.6) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 84 (4.6) 84 (4.6) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 84 (4.6) 27 (3.0) 27 (3.0) 84 (4.6) 84 (4.6) 27 (3.0) 27 (3.0) 84 (4.6) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 84 (4.6) 84 (4.6) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 84 (4.6) 27 (3.0) 27 (3.0) 84 (4.6) 153 (6.6) 84 (4.6) 84 (4.6) 126 (5.9) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 126 (5.9) 153 (6.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 126 (5.9) 84 (4.6) 84 (4.6) 126 (5.9) 50 (3.7) 0 (2.2) 0 (2.2) 0 (2.2) 50 (3.7) 88 (4.8) 38 (3.3) 38 (3.3) 38 (3.3) 69 (4.2) 67 (4.1) 67 (4.1) 67 (4.1) 19 (2.8) 19 (2.8) 19 (2.8) 84 (4.6) 84 (4.6) 19 (2.8) 19 (2.8) 19 (2.8) 67 (4.1) 67 (4.1) 19 (2.8) 84 (4.6) 84 (4.6) 84 (4.6) 19 (2.8) 19 (2.8) 67 (4.1) 67 (4.1) 19 (2.8) 19 (2.8) 67 (4.1) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 67 (4.1) 27 (3.0) 84 (4.6) 126 (5.9) 19 (2.8) 15 (2.6) 15 (2.6) 84 (4.6) 126 (5.9) 19 (2.8) 19 (2.8) 19 (2.8) 19 (2.8) 19 (2.8) 84 (4.6) 84 (4.6) 153 (6.6) 153 (6.6) 84 (4.6) 19 (2.8) 19 (2.8) 27 (3.0) 84 (4.6) 126 (5.9) 153 (6.6) 84 (4.6) 84 (4.6) 19 (2.8) 19 (2.8) 126 (5.9) 15 (2.6) 67 (4.1) 19 (2.8) 15 (2.6) 153 (6.6) 153 (6.6) 15 (2.6) 126 (5.9) 84 (4.6) 84 (4.6) 27 (3.0) 84 (4.6) 126 (5.9) 19 (2.8) Array 1 372 Panels Array 3 55 Panels Array 4 15 Panels LEGEND Wind Load Pressure (psf) 60 (4.5) (lbs) EN G I N E E R ' S S E A L DRAWING NO. CL I E N T : PR O J E C T : PROVIDER 1050 KING ST. W, SUITE 03A104 TORONTO, ONTARIO M6K 0C7 CANADA TOLL - FREE TEL: 1.888.661.3204 LOCAL TEL: 416 532 2500 EMAIL: info@kbracking.com WWW.KBRACKING.COM DRAWN BY: CHECKED BY: VERSION: DR A W I N G T I T L E : PROJECT NO.: DATE: SHEET: OF NOTE: 843 Modules (Canadian 540W) DC Output: 455.22 kW (DC) EkonoRack L: 5 Degree Tilt Row Spacing: 4.59' Inter-Row Spacing: 0.88' Setback from edge: 4' - 2023/02/22 4 M-3.1 K.P.-3 LO A D A R R A Y 1 Fo s t e r P r i n t i n g RE P R e n e w 70 0 E a s t A l t o n 14 Sa n t a A n a . C A . 9 2 7 0 5 700 E Alton Ave - 101114289 & 2017906306/06/23 153 (6.6) 84 (4.6) 84 (4.6) 126 (5.9) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 126 (5.9) 153 (6.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 126 (5.9) 84 (4.6) 27 (3.0) 27 (3.0) 84 (4.6) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 84 (4.6) 84 (4.6) 84 (4.6) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 126 (5.9) 84 (4.6) 27 (3.0) 27 (3.0) 27 (3.0) 84 (4.6) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 109 (5.4) 84 (4.6) 27 (3.0) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 126 (5.9) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 35 (3.2) 27 (3.0) 15 (2.6) 15 (2.6) 19 (2.8) 19 (2.8) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 84 (4.6) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 67 (4.1) 19 (2.8) 15 (2.6) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 84 (4.6) 126 (5.9) 199 (8.0) 109 (5.4) 84 (4.6) 164 (7.0) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 27 (3.0) 84 (4.6) 109 (5.4) 35 (3.2) 27 (3.0) 109 (5.4) 84 (4.6) 27 (3.0) 15 (2.6) 15 (2.6) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 84 (4.6) 27 (3.0) 84 (4.6) 126 (5.9) 27 (3.0) 27 (3.0) 27 (3.0) 84 (4.6) 84 (4.6) 27 (3.0) 15 (2.6) 15 (2.6) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 19 (2.8) 15 (2.6) 15 (2.6) 84 (4.6) 19 (2.8) 15 (2.6) 15 (2.6) 19 (2.8) 153 (6.6) 84 (4.6) 15 (2.6) 15 (2.6) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 84 (4.6) 84 (4.6) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 25 (2.9) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 25 (2.9) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 27 (3.0) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 153 (6.6) 84 (4.6) 15 (2.6) 15 (2.6) 84 (4.6) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 84 (4.6) 84 (4.6) 15 (2.6) 15 (2.6) 84 (4.6) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 27 (3.0) 27 (3.0) 15 (2.6) 19 (2.8) 84 (4.6) 27 (3.0) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 84 (4.6) 84 (4.6) 15 (2.6) 15 (2.6) 19 (2.8) 84 (4.6) 27 (3.0) 15 (2.6) 19 (2.8) 153 (6.6) 84 (4.6) 19 (2.8) 19 (2.8) 84 (4.6) 84 (4.6) 19 (2.8) 19 (2.8) 67 (4.1) 67 (4.1) 19 (2.8) 84 (4.6) 84 (4.6) 19 (2.8) 19 (2.8) 19 (2.8) 67 (4.1) 67 (4.1) 19 (2.8) 19 (2.8) 67 (4.1) 84 (4.6) 84 (4.6) 19 (2.8) 67 (4.1) 19 (2.8) 15 (2.6) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 27 (3.0) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 84 (4.6) 84 (4.6) 15 (2.6) 19 (2.8) 19 (2.8) 15 (2.6) 27 (3.0) 27 (3.0) 84 (4.6) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 84 (4.6) 84 (4.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 27 (3.0) 27 (3.0) 15 (2.6) 19 (2.8) 84 (4.6) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 27 (3.0) 27 (3.0) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 15 (2.6) 19 (2.8) 27 (3.0) 15 (2.6) 19 (2.8) 67 (4.1) 67 (4.1) 67 (4.1) 19 (2.8) 19 (2.8) 19 (2.8) 84 (4.6) 84 (4.6) 19 (2.8) 19 (2.8) 19 (2.8) 67 (4.1) 67 (4.1) 19 (2.8) 84 (4.6) 84 (4.6) 84 (4.6) 19 (2.8) 19 (2.8) 67 (4.1) 67 (4.1) 19 (2.8) 19 (2.8) 67 (4.1) 27 (3.0) 84 (4.6) 126 (5.9) 84 (4.6) 19 (2.8) 19 (2.8) 84 (4.6) 126 (5.9) 84 (4.6) Array 2 383 Panels LEGEND Wind Load Pressure (psf) 60 (4.5) (lbs) EN G I N E E R ' S S E A L DRAWING NO. CL I E N T : PR O J E C T : PROVIDER 1050 KING ST. W, SUITE 03A104 TORONTO, ONTARIO M6K 0C7 CANADA TOLL - FREE TEL: 1.888.661.3204 LOCAL TEL: 416 532 2500 EMAIL: info@kbracking.com WWW.KBRACKING.COM DRAWN BY: CHECKED BY: VERSION: DR A W I N G T I T L E : PROJECT NO.: DATE: SHEET: OF NOTE: 843 Modules (Canadian 540W) DC Output: 455.22 kW (DC) EkonoRack L: 5 Degree Tilt Row Spacing: 4.59' Inter-Row Spacing: 0.88' Setback from edge: 4' - 2023/02/22 5 M-3.2 K.P.-3 LO A D A R R A Y 2 Fo s t e r P r i n t i n g RE P R e n e w 70 0 E a s t A l t o n 14 Sa n t a A n a . C A . 9 2 7 0 5 700 E Alton Ave - 101114289 & 2017906306/06/23 84 (4.6) 27 (3.0) 27 (3.0) 15 (2.6) 19 (2.8) 15 153 (6.6) 84 (4.6) 84 (4.6) 19 (2.8) 19 19 (2.8) 15 (2.6) 84 (4.6) 19 (2.8) 84 (4.6) 15 19 (2.8) 15 (2.6) 84 (4.6) 19 (2.8) 27 (3.0) 15 19 (2.8) 15 (2.6) 19 (2.8) 67 (4.1) 84 (4.6) 15 19 (2.8) 15 (2.6) 19 (2.8) 126 (5.9) 19 (2.8) 15 (2.6) 15 (2.6) 84 (4.6) 84 (4.6) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 84 (4.6) 84 (4.6) 84 (4.6) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 27 (3.0) 84 (4.6) 126 (5.9) 153 (6.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 126 (5.9) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 84 (4.6) 67 (4.1) 153 84 84 19 19 126 (5.9) 15 (2.6) 67 (4.1) 19 (2.8) 15 (2.6) 153 (6.6) 153 (6.6) Array 3 55 Panels LEGEND Wind Load Pressure (psf) 60 (4.5) (lbs) EN G I N E E R ' S S E A L DRAWING NO. CL I E N T : PR O J E C T : PROVIDER 1050 KING ST. W, SUITE 03A104 TORONTO, ONTARIO M6K 0C7 CANADA TOLL - FREE TEL: 1.888.661.3204 LOCAL TEL: 416 532 2500 EMAIL: info@kbracking.com WWW.KBRACKING.COM DRAWN BY: CHECKED BY: VERSION: DR A W I N G T I T L E : PROJECT NO.: DATE: SHEET: OF NOTE: 843 Modules (Canadian 540W) DC Output: 455.22 kW (DC) EkonoRack L: 5 Degree Tilt Row Spacing: 4.59' Inter-Row Spacing: 0.88' Setback from edge: 4' - 2023/02/22 6 M-3.3 K.P.-3 LO A D A R R A Y 3 Fo s t e r P r i n t i n g RE P R e n e w 70 0 E a s t A l t o n 14 Sa n t a A n a . C A . 9 2 7 0 5 700 E Alton Ave - 101114289 & 2017906306/06/23 50 (3.7) 0 (2.2) 0 (2.2) 0 (2.2) 50 (3.7) 114 (5.5) 50 (3.7) 50 (3.7) 50 (3.7) 89 (4.8) 88 (4.8) 38 (3.3) 38 (3.3) 38 (3.3) 69 (4.2) Array 4 15 Panels LEGEND Wind Load Pressure (psf) 60 (4.5) (lbs) EN G I N E E R ' S S E A L DRAWING NO. CL I E N T : PR O J E C T : PROVIDER 1050 KING ST. W, SUITE 03A104 TORONTO, ONTARIO M6K 0C7 CANADA TOLL - FREE TEL: 1.888.661.3204 LOCAL TEL: 416 532 2500 EMAIL: info@kbracking.com WWW.KBRACKING.COM DRAWN BY: CHECKED BY: VERSION: DR A W I N G T I T L E : PROJECT NO.: DATE: SHEET: OF NOTE: 843 Modules (Canadian 540W) DC Output: 455.22 kW (DC) EkonoRack L: 5 Degree Tilt Row Spacing: 4.59' Inter-Row Spacing: 0.88' Setback from edge: 4' - 2023/02/22 7 M-3.4 K.P.-3 LO A D A R R A Y 4 Fo s t e r P r i n t i n g RE P R e n e w 70 0 E a s t A l t o n 14 Sa n t a A n a . C A . 9 2 7 0 5 700 E Alton Ave - 101114289 & 2017906306/06/23 114 (5.5) 38 (3.3) 38 (3.3) 38 (3.3) 38 (3.3) 38 (3.3) 38 (3.3) 38 (3.3) 69 (4.2) 69 (4.2) 38 (3.3) 38 (3.3) 38 (3.3) 38 (3.3) 38 (3.3) 38 (3.3) 38 (3.3) 88 (4.8) Array 5 18 Panels LEGEND Wind Load Pressure (psf) 60 (4.5) (lbs) EN G I N E E R ' S S E A L DRAWING NO. CL I E N T : PR O J E C T : PROVIDER 1050 KING ST. W, SUITE 03A104 TORONTO, ONTARIO M6K 0C7 CANADA TOLL - FREE TEL: 1.888.661.3204 LOCAL TEL: 416 532 2500 EMAIL: info@kbracking.com WWW.KBRACKING.COM DRAWN BY: CHECKED BY: VERSION: DR A W I N G T I T L E : PROJECT NO.: DATE: SHEET: OF NOTE: 843 Modules (Canadian 540W) DC Output: 455.22 kW (DC) EkonoRack L: 5 Degree Tilt Row Spacing: 4.59' Inter-Row Spacing: 0.88' Setback from edge: 4' - 2023/02/22 8 M-3.5 K.P.-3 LO A D A R R A Y 5 Fo s t e r P r i n t i n g RE P R e n e w 70 0 E a s t A l t o n 14 Sa n t a A n a . C A . 9 2 7 0 5 700 E Alton Ave - 101114289 & 2017906306/06/23 EN G I N E E R ' S S E A L DRAWING NO. CL I E N T : PR O J E C T : PROVIDER 1050 KING ST. W, SUITE 03A104 TORONTO, ONTARIO M6K 0C7 CANADA TOLL - FREE TEL: 1.888.661.3204 LOCAL TEL: 416 532 2500 EMAIL: info@kbracking.com WWW.KBRACKING.COM DRAWN BY: CHECKED BY: VERSION: DR A W I N G T I T L E : PROJECT NO.: DATE: SHEET: OF NOTE: 843 Modules (Canadian 540W) DC Output: 455.22 kW (DC) EkonoRack L: 5 Degree Tilt Row Spacing: 4.59' Inter-Row Spacing: 0.88' Setback from edge: 4' - 2023/02/22 9 M-4.0 K.P.-3 PA V E R L A Y O U T Fo s t e r P r i n t i n g RE P R e n e w 70 0 E a s t A l t o n 14 Sa n t a A n a . C A . 9 2 7 0 5 Foster Printing - 455.2 kW (dc) 700 East Alton, Santa Ana. CA. 92705 Total Ballast (lb) Stone Quantities Ballast Trays16x7.5x3.5in 8x3.5x2.25in Large (32 lb)Small (5 lb) Array 01 13994.00 227 1346 3 Array 02 14241.00 243 1293 3 Array 03 3100.00 60 236 0 Array 04 729.00 12 69 0 Array 05 918.00 14 94 0 Totals 32982.00 556 3038 6 Recommended Ballast 32684.42 Additional Ballast Weight 297.58 700 E Alton Ave - 101114289 & 2017906306/06/23 2/4 2/0 1/1 0/3 1/1 1/2 0/4 0/3 0/3 1/3 1/5 1/2 1/0 0/3 1/1 1/5 1/1 0/3 0/3 0/3 1/1 1/5 1/1 0/3 0/3 0/3 1/0 1/2 0/4 0/3 0/3 2/4 2/0 1/1 0/3 1/1 1/5 1/1 0/3 1/0 1/4 0/4 1/0 1/1 1/5 1/1 0/3 0/3 1/0 1/2 1/2 1/2 1/0 0/4 0/5 2/1 1/5 1/1 1/0 0/5 1/5 1/2 0/5 0/2 0/5 1/2 0/5 0/2 0/4 0/3 0/3 0/4 0/5 1/2 0/5 0/2 0/2 0/4 0/3 0/3 0/4 0/2 0/4 1/1 1/2 0/5 0/4 0/4 0/3 1/0 0/5 0/3 0/4 0/3 0/4 1/0 1/0 0/4 1/0 0/4 1/2 0/3 1/0 0/3 0/3 0/4 1/1 0/5 1/5 0/5 1/5 0/4 1/1 0/3 1/0 1/0 0/4 1/0 0/4 1/2 0/3 1/0 0/3 0/3 0/3 0/3 0/4 1/1 0/5 1/5 0/4 1/1 0/3 0/3 0/3 0/3 0/3 1/0 1/1 1/2 1/5 1/2 1/1 1/2 0/3 1/2 0/3 0/5 1/1 1/0 0/5 0/5 1/2 1/5 1/1 0/3 0/3 0/4 0/4 0/4 0/4 0/3 1/1 1/5 1/1 0/3 0/3 0/3 0/4 0/4 0/4 0/3 0/3 0/3 1/0 1/2 0/4 0/3 0/3 1/5 1/3 1/2 1/5 1/2 0/5 0/4 0/3 0/3 0/3 0/3 0/4 0/4 0/4 0/5 0/5 0/4 0/3 0/4 0/4 0/4 0/4 0/3 0/3 0/3 0/3 1/1 0/4 0/3 0/3 3/2 2/0 2/0 1/2 1/3 1/0 0/4 0/3 0/3 0/3 0/3 0/4 0/5 0/5 1/2 1/5 1/1 0/3 0/4 0/5 0/5 0/4 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 2/3 1/2 1/1 0/3 0/5 0/3 0/3 0/3 0/3 0/3 1/1 1/5 2/0 1/5 1/2 1/2 1/0 1/1 1/5 1/5 1/1 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 1/0 0/3 0/3 0/3 0/3 1/0 1/2 1/4 1/0 0/4 0/3 0/5 1/2 1/2 1/3 1/1 0/4 0/4 0/3 0/3 0/3 0/3 0/3 0/3 3/7 1/5 1/1 2/4 2/4 1/2 0/3 1/4 0/3 0/3 0/3 0/3 1/2 1/5 0/5 0/4 0/3 0/3 0/3 0/3 0/3 0/3 1/4 2/1 1/2 1/0 0/3 0/3 0/3 0/3 0/3 2/4 1/5 1/5 1/1 0/3 0/3 0/3 0/3 0/3 0/3 0/2 0/3 0/3 0/3 0/3 0/3 1/3 0/3 1/5 1/5 1/1 1/5 1/2 1/0 1/0 0/3 1/0 0/3 0/3 0/3 0/3 0/2 0/3 0/3 0/3 0/3 0/3 0/3 1/4 1/3 0/2 1/1 1/1 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 1/0 1/0 0/4 1/3 1/1 0/3 0/3 0/3 0/3 1/1 1/0 0/3 1/2 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 1/1 1/0 0/3 0/3 0/3 0/3 0/3 0/3 0/4 1/1 1/5 1/2 0/3 0/3 0/3 0/3 0/3 0/4 1/1 1/2 2/3 1/5 1/4 1/0 0/3 0/3 0/3 1/0 0/3 0/3 0/3 0/3 1/1 1/0 0/5 1/2 1/5 0/4 0/4 0/4 0/4 0/4 0/5 0/5 2/0 1/4 1/1 1/0 0/4 1/1 2/0 1/5 1/2 1/1 0/4 1/1 1/0 1/5 1/3 0/5 1/2 1/5 1/2 0/5 0/5 0/5 0/5 0/5 0/5 1/5 1/2 1/3 1/5 0/5 0/5 0/5 1/5 0/5 1/5 0/5 1/5 0/5 1/5 1/3 1/5 0/5 1/5 1/3 2/4 2/0 1/5 2/3 1/4 2/3 1/5 1/5 1/5 1/5 1/5 1/5 2/3 1/4 2/0 2/4 1/5 1/5 1/5 1/5 1/5 1/5 2/3 1/5 2/4 1/5 2/3 1/5 1/5 1/2 1/2 1/4 1/0 1/4 1/2 1/2 1/2 1/2 1/2 1/2 1/4 1/0 1/5 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/4 1/1 1/5 1/2 1/4 1/1 1/2 1/1 0/4 0/4 1/1 1/0 1/0 0/4 0/4 0/4 0/5 0/3 1/0 0/4 0/3 0/3 0/4 0/2 0/2 0/5 1/2 0/5 0/2 0/2 0/4 0/3 0/3 0/4 0/5 1/2 1/2 0/5 0/2 0/4 0/3 0/3 0/4 0/2 0/4 0/4 1/2 1/2 1/2 1/2 1/1 0/4 1/3 2/1 1/3 1/0 1/0 1/0 1/4 1/0 0/2 0/2 0/2 0/2 3/5 2/0 2/3 1/2 1/1 1/5 0/2 1/2 1/5 1/4 1/0 1/5 1/1 1/2 0/5 0/2 1/4 1/1 1/0 0/4 0/4 2/4 1/2 1/2 2/4 1/2 1/2 2/2 1/4 2/1 1/2 Array 1 372 Panels Array 3 55 Panels Array 4 15 Panels LEGEND # OF STONES LARGE / SMALL 1/2 1/11/1 2/1 BALLAST TRAY REQUIRED EN G I N E E R ' S S E A L DRAWING NO. CL I E N T : PR O J E C T : PROVIDER 1050 KING ST. W, SUITE 03A104 TORONTO, ONTARIO M6K 0C7 CANADA TOLL - FREE TEL: 1.888.661.3204 LOCAL TEL: 416 532 2500 EMAIL: info@kbracking.com WWW.KBRACKING.COM DRAWN BY: CHECKED BY: VERSION: DR A W I N G T I T L E : PROJECT NO.: DATE: SHEET: OF NOTE: 843 Modules (Canadian 540W) DC Output: 455.22 kW (DC) EkonoRack L: 5 Degree Tilt Row Spacing: 4.59' Inter-Row Spacing: 0.88' Setback from edge: 4' - 2023/02/22 10 M-4.1 K.P.-3 PA V E R A R R A Y 1 Fo s t e r P r i n t i n g RE P R e n e w 70 0 E a s t A l t o n 14 Sa n t a A n a . C A . 9 2 7 0 5 700 E Alton Ave - 101114289 & 2017906306/06/23 2/4 1/5 1/2 2/0 1/5 1/2 2/3 1/4 1/4 1/0 2/3 1/4 1/5 1/2 1/5 1/2 1/5 1/2 1/5 1/2 1/5 1/2 1/5 1/2 2/3 1/4 1/4 1/0 1/5 1/1 2/4 1/5 2/1 1/2 2/4 1/2 2/1 1/2 1/5 1/2 1/5 1/2 1/5 1/2 1/5 1/2 2/6 1/4 2/1 1/1 1/5 1/3 0/5 1/2 1/3 1/3 1/2 0/5 0/5 0/5 0/5 0/5 0/5 1/2 1/5 1/3 1/3 1/5 1/3 1/2 1/5 1/5 1/5 2/0 2/1 1/1 1/1 1/0 0/4 0/4 1/1 1/1 0/4 0/4 0/4 0/4 0/4 0/4 0/4 0/4 1/3 2/0 1/1 1/1 1/0 0/2 1/3 1/2 1/2 1/4 1/0 0/3 0/3 0/3 0/3 1/1 1/1 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 1/1 1/5 1/1 0/3 0/3 1/0 0/3 0/3 0/5 0/3 0/3 0/3 0/3 0/3 1/0 1/0 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 1/0 1/2 1/0 0/3 0/3 0/3 0/3 0/5 1/2 1/4 1/0 1/4 2/3 1/3 2/0 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/2 0/3 0/3 0/3 0/3 0/3 1/1 2/3 1/4 2/3 3/3 2/0 1/3 2/6 2/2 1/1 1/0 0/4 0/3 0/4 0/4 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/4 0/5 0/4 0/3 0/3 0/3 0/3 0/3 1/0 1/5 1/3 1/4 2/0 1/4 1/0 2/0 1/4 1/5 1/3 0/4 0/3 0/4 0/4 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/4 0/5 0/4 0/3 0/3 0/3 0/3 0/3 1/1 1/0 1/4 2/2 1/2 0/4 0/4 1/1 1/0 2/4 2/0 1/1 0/3 1/1 1/1 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 1/1 1/5 1/1 0/3 0/3 0/2 0/3 0/3 0/3 0/3 1/1 1/3 0/3 1/0 0/3 0/3 0/3 1/5 1/2 1/0 0/4 1/0 1/0 0/3 0/3 0/3 0/3 0/4 0/4 0/4 0/3 1/0 1/2 1/0 0/3 0/3 0/2 0/3 0/3 0/3 0/3 0/4 1/1 1/0 0/3 0/3 0/3 0/3 0/4 0/3 0/2 0/3 0/3 0/3 0/4 0/5 0/5 0/4 0/3 0/2 0/2 0/3 0/3 0/3 0/4 0/4 0/4 0/3 0/3 0/3 0/3 0/3 0/3 0/3 0/3 1/5 1/2 0/4 1/0 1/0 0/4 1/0 0/3 0/3 0/4 1/2 1/5 1/1 0/3 1/0 0/3 1/0 0/3 0/3 0/4 0/5 0/4 0/3 0/3 0/3 0/4 0/4 0/4 0/3 0/3 2/4 2/0 1/1 0/3 1/1 1/2 0/4 0/3 0/3 1/3 1/5 1/2 1/0 0/3 1/1 1/5 1/2 1/1 0/3 0/3 0/3 1/1 1/5 1/1 0/3 0/3 0/3 1/0 1/2 0/4 0/3 0/3 2/4 2/0 1/1 0/3 1/1 1/5 1/1 0/3 1/0 1/4 0/4 1/0 1/1 1/5 1/1 0/3 0/3 1/0 1/2 1/2 1/2 1/0 0/4 0/5 2/1 1/5 1/1 1/0 0/5 1/5 1/2 0/5 0/2 0/5 1/2 0/5 0/2 0/4 0/3 0/3 0/4 0/5 1/2 0/5 0/2 0/2 0/4 0/3 0/3 0/4 0/2 0/4 1/1 1/2 0/5 0/4 0/4 0/3 1/0 0/5 0/3 0/4 0/3 0/4 1/0 1/0 0/4 1/0 0/4 1/2 0/3 1/0 0/3 0/3 0/4 1/1 0/5 1/5 0/5 1/5 0/4 1/1 0/3 1/0 1/0 0/4 1/0 0/4 1/2 0/3 1/0 0/3 0/3 0/3 0/3 0/4 1/1 0/5 1/5 0/4 1/1 0/3 0/3 0/3 0/3 0/3 1/0 1/1 1/2 1/5 1/2 1/1 1/2 0/3 1/2 0/3 0/5 1/1 1/0 0/5 0/5 1/2 1/5 1/1 0/3 0/3 0/4 0/4 0/4 0/4 0/3 1/1 1/5 1/1 0/3 0/3 0/3 0/4 0/4 0/4 0/3 0/3 0/3 1/0 1/2 0/4 0/3 0/3 1/0 0/4 0/3 0/3 0/4 0/2 0/2 0/5 1/2 0/5 0/2 0/2 0/4 0/3 0/3 0/4 0/5 1/2 1/2 0/5 0/2 0/4 0/3 0/3 0/4 0/2 0/4 0/4 1/3 1/0 0/2 1/4 1/0 Array 2 383 Panels LEGEND # OF STONES LARGE / SMALL 1/2 1/11/1 2/1 BALLAST TRAY REQUIRED EN G I N E E R ' S S E A L DRAWING NO. CL I E N T : PR O J E C T : PROVIDER 1050 KING ST. W, SUITE 03A104 TORONTO, ONTARIO M6K 0C7 CANADA TOLL - FREE TEL: 1.888.661.3204 LOCAL TEL: 416 532 2500 EMAIL: info@kbracking.com WWW.KBRACKING.COM DRAWN BY: CHECKED BY: VERSION: DR A W I N G T I T L E : PROJECT NO.: DATE: SHEET: OF NOTE: 843 Modules (Canadian 540W) DC Output: 455.22 kW (DC) EkonoRack L: 5 Degree Tilt Row Spacing: 4.59' Inter-Row Spacing: 0.88' Setback from edge: 4' - 2023/02/22 11 M-4.2 K.P.-3 PA V E R A R R A Y 2 Fo s t e r P r i n t i n g RE P R e n e w 70 0 E a s t A l t o n 14 Sa n t a A n a . C A . 9 2 7 0 5 700 E Alton Ave - 101114289 & 2017906306/06/23 1/2 1/5 0/5 0/4 0/3 0/3 2/4 1/5 1/5 1/1 0/3 0/3 1/3 0/3 1/5 1/5 1/1 1/5 1/2 1/0 1/0 1/0 0/3 0/3 1/4 1/3 0/2 1/1 1/1 0/3 0/3 1/0 1/0 0/4 1/3 1/1 0/3 0/3 0/3 0/3 0/3 1/1 1/0 1/5 1/4 1/0 0/3 0/3 0/3 1/0 2/0 1/4 1/1 1/0 0/4 1/1 2/0 1/5 1/2 1/5 1/2 1/3 1/5 0/5 0/5 0/5 1/5 0/5 1/5 0/5 1/5 0/5 1/5 1/3 2/3 1/4 2/0 2/4 1/5 1/5 1/5 1/5 1/5 1/5 2/3 1/5 1/4 1/0 1/5 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/4 1/1 1/2 1/2 1/2 1/2 1/1 0/4 1/0 1/5 1/1 1/2 0/5 0/2 1/4 1/1 1/0 0/4 0/4 2/4 1/2 1/2 2/4 1/2 Array 3 55 Panels LEGEND # OF STONES LARGE / SMALL 1/2 1/11/1 2/1 BALLAST TRAY REQUIRED EN G I N E E R ' S S E A L DRAWING NO. CL I E N T : PR O J E C T : PROVIDER 1050 KING ST. W, SUITE 03A104 TORONTO, ONTARIO M6K 0C7 CANADA TOLL - FREE TEL: 1.888.661.3204 LOCAL TEL: 416 532 2500 EMAIL: info@kbracking.com WWW.KBRACKING.COM DRAWN BY: CHECKED BY: VERSION: DR A W I N G T I T L E : PROJECT NO.: DATE: SHEET: OF NOTE: 843 Modules (Canadian 540W) DC Output: 455.22 kW (DC) EkonoRack L: 5 Degree Tilt Row Spacing: 4.59' Inter-Row Spacing: 0.88' Setback from edge: 4' - 2023/02/22 12 M-4.3 K.P.-3 PA V E R A R R A Y 3 Fo s t e r P r i n t i n g RE P R e n e w 70 0 E a s t A l t o n 14 Sa n t a A n a . C A . 9 2 7 0 5 700 E Alton Ave - 101114289 & 2017906306/06/23 1/4 1/2 1/1 1/2 0/5 0/4 0/5 0/4 1/3 1/1 1/1 1/0 1/2 1/0 0/5 0/5 1/1 0/4 1/0 0/4 0/4 0/4 0/5 0/3 Array 4 15 Panels LEGEND # OF STONES LARGE / SMALL 1/2 1/11/1 2/1 BALLAST TRAY REQUIRED EN G I N E E R ' S S E A L DRAWING NO. CL I E N T : PR O J E C T : PROVIDER 1050 KING ST. W, SUITE 03A104 TORONTO, ONTARIO M6K 0C7 CANADA TOLL - FREE TEL: 1.888.661.3204 LOCAL TEL: 416 532 2500 EMAIL: info@kbracking.com WWW.KBRACKING.COM DRAWN BY: CHECKED BY: VERSION: DR A W I N G T I T L E : PROJECT NO.: DATE: SHEET: OF NOTE: 843 Modules (Canadian 540W) DC Output: 455.22 kW (DC) EkonoRack L: 5 Degree Tilt Row Spacing: 4.59' Inter-Row Spacing: 0.88' Setback from edge: 4' - 2023/02/22 13 M-4.4 K.P.-3 PA V E R A R R A Y 4 Fo s t e r P r i n t i n g RE P R e n e w 70 0 E a s t A l t o n 14 Sa n t a A n a . C A . 9 2 7 0 5 700 E Alton Ave - 101114289 & 2017906306/06/23 1/2 2/2 1/5 1/1 0/4 1/1 0/4 1/1 0/4 1/1 0/4 1/1 0/4 1/1 0/4 1/1 0/5 1/4 0/4 1/2 0/5 0/4 0/4 0/4 0/4 0/4 0/4 0/4 1/1 0/5 Array 5 18 Panels LEGEND # OF STONES LARGE / SMALL 1/2 1/11/1 2/1 BALLAST TRAY REQUIRED EN G I N E E R ' S S E A L DRAWING NO. CL I E N T : PR O J E C T : PROVIDER 1050 KING ST. W, SUITE 03A104 TORONTO, ONTARIO M6K 0C7 CANADA TOLL - FREE TEL: 1.888.661.3204 LOCAL TEL: 416 532 2500 EMAIL: info@kbracking.com WWW.KBRACKING.COM DRAWN BY: CHECKED BY: VERSION: DR A W I N G T I T L E : PROJECT NO.: DATE: SHEET: OF NOTE: 843 Modules (Canadian 540W) DC Output: 455.22 kW (DC) EkonoRack L: 5 Degree Tilt Row Spacing: 4.59' Inter-Row Spacing: 0.88' Setback from edge: 4' - 2023/02/22 14 M-4.5 K.P.-3 PA V E R A R R A Y 5 Fo s t e r P r i n t i n g RE P R e n e w 70 0 E a s t A l t o n 14 Sa n t a A n a . C A . 9 2 7 0 5 700 E Alton Ave - 101114289 & 2017906306/06/23 To scale on 24x36 paper X___________________________ Confidentiality Statement: 2/24/2023 7:36:41 PM Spec Sheets FO S T E R P R I N T I N G C o 70 0 E A l t o n A v e Sa n t a A n a C A , 9 2 7 0 5 SP101 This drawing is the property of RENEWABLE ENERGY PARTNERS. This information is confidential and is to be used only in connection with work described by RENEWABLE ENERGY PARTNERS. No part is to be discolosed to others without written permission from RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS LIC # 989857 EXP: 01/31/2024 RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS www.RENEWEPI.com 855-519-6633 170 MAPLE ST, STE 105 CORONA, CA 92881 12" = 1'-0"1 Spec Sheet Module 12" = 1'-0"3 Spec Sheet PV Wire 12" = 1'-0"2 Spec Sheet Solectria Inverter 12" = 1'-0"4 Spec Sheet Tigo TS4-A-2F No . De s c r ip ti o n Da t e 700 E Alton Ave - 101114289 & 2017906306/06/23 1 To scale on 24x36 paper X___________________________ Confidentiality Statement: 5/2/2023 1:25:01 PM Spec Sheets FO S T E R P R I N T I N G C o 70 0 E A l t o n A v e Sa n t a A n a C A , 9 2 7 0 5 SP102 This drawing is the property of RENEWABLE ENERGY PARTNERS. This information is confidential and is to be used only in connection with work described by RENEWABLE ENERGY PARTNERS. No part is to be discolosed to others without written permission from RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS LIC # 989857 EXP: 01/31/2024 RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS www.RENEWEPI.com 855-519-6633 170 MAPLE ST, STE 105 CORONA, CA 92881 12" = 1'-0"1 Spec Sheet KB Racking Ballasts No . De sc r i p t i o n Da t e 1 A H J C o r r e c tio n s 5- 2 - 23 700 E Alton Ave - 101114289 & 2017906306/06/23 To scale on 24x36 paper X___________________________ GENERAL NOTES:PROJECT SCOPE:DRAWING INDEX PERMITTING / PLANNING NOTES: PROJECT ADDRESS AERIAL PHOTO:PROJECT TEAM: THIS INSTALLATION CONSISTS OF A NEW ROOFMOUNTED PHOTOVOLTAIC (PV) SYSTEM. THE PV SYSTEM IS STATIC MOUNTED. THIS SYSTEM WILL BE INTERCONNECTED TO AND WILL BE OPERATED IN PARALLEL WITH THE ELECTRIC GRID PER THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND UTILITY INTERCONNECT AGREEMENT CONDITIONS OF APPROVAL: 1. ALL CONSTRUCTION SHALL OCCUR BETWEEN THE HOURS OF 7AM & 7PM, EXCEPT FOR THE PURPOSE OF EMERGENCIES. 1. THIS PV SYSTEM INSTALLATION IS SUBJECT TO INSPECTION BY THE AUTHORITY HAVING JURISDICTION 2. THIS PROJECT SHALL CONFORM TO THE FOLLOWING CODE VERSIONS: 2022 CALIFORNIA BUILDING CODE (CBC 2022) 2022 CALIFORNIA ELECTRIC CODE (CEC 2022) 2022 CALIFORNIA FIRE CODE (CFC 2022) 2022 CALIFORNIA ENERGY CODE (CEnC 2022) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSG 2022) 2022 CALIFORNIA PLUMBING CODE (CPC 2022) 2022 CALIFORNIA MECHANICAL CODE (CMC 2022) 3. MODULE LEVEL RAPID SHUT-DOWN EQUIPMENT USED WHICH MEETS 690.12 RAPID SHUTDOWN REQUIREMENTS. 4. 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. 5. ELECTRICAL EQUIPMENT SHALL BE LISTED OR CERTIFIED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 6. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULLBOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ECT.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. 7. A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE. 8. INSTALLATION OF THE PV SYSTEM IN PARALLEL WITH THE UTILITY POWER SHALL BE INSTALLED ONLY BY QUALIFIED PERSONS. 705.6. 9. THE OUTPUT CHARACTERISTICS OF THE PV SYSTEM SHALL BE COMPATIBLE WITH THE VOLTAGE, WAVE SHAPE, AND FREQUENCY OF THAT OF THE UTILITY OUTPUT. 705.14. 10. INTERCONNECTED ELECTRIC POWER PRODUCTION SOURCES SHALL BE GROUNDED IN ACCORDANCE WITH ARTICLE 250. 705.50. SITE CONTACT: CONTRACTOR: Confidentiality Statement: VICINITY MAP: 1. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE 2022 TITLE 24 OF THE CALIFORNIA BUILDING CODE, CMC,CPC. CEC AND ALL APPLICABLE LOCAL CODES, ORDINANCES, AND STATE AMENDMENTS. 2. THE CONTRACTOR SHALL CHECK ALL DRAWINGS IMMEDIATELY UPON THEIR RECEIPT AND SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE STARTING WORK. ALL ARCHITECTS AND ENGINEERS SHALL BE NOTIFIED OF ANY DISCREPANCIES. 3. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY SHOWN, NOTED, OR APPROVED BY ALL. NOTCH DETAILS, IF PROVIDED ARE FOR GENERAL GUIDANCE ONLY. ALL SHALL BE CONTACTED TO APPROVE LOCATIONS OF PROPOSED NOTCHES. 4. CONNECTIONS AND IMPLIED CONSTRUCTION ASSEMBLIES THAT ARE NOT SPECIFICALLY DESCRIBED OR DETAILED SHALL BE CONSTRUCTED USING STANDARD CONSTRUCTION PRACTICES IN COMPLIANCE WITH THE GOVERNING CODES AND ORDINANCES. 5. WHEN DETAILS LABELED "TYPICAL” OR "SIMILAR" ARE GIVEN ON DRAWINGS, THE CONTRACTOR SHALL APPLY THE INTENT OF THE DETAIL TO THAT SPECIFIC CONDITION. 6. WRITTEN INFORMATION AND DIMENSIONS SHALL HAVE PRECEDENCE OVER GRAPHIC INFORMATION. DO NOT SCALE. 7. DRAWINGS AND SPECIFICATIONS FOR THIS WORK HAVE BEEN PREPARED IN ACCORDANCE WITH GENERALLY ACCEPTED STANDARDS OF PRACTICE TO MEET THE MINIMUM REQUIREMENTS DF THE CURRENT EDITION DF THE CBC. ANY DISCREPANCIES ON THE PLANS OR ANY DE\/IATIONS FROM THE PLANS WHICH ARE NECESSITATED BY FIELD CONDITIONS OR ANY CONDITION DIFFERENT FROM THOSE INDICATED ON THE PLANS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER. ALL WORK IS TO BE COORDINATED SO THAT COOPERATION BETWEEN THE TRADES WHERE REQUIRED IS ACCOMPLISHED. 8. CONTRACTOR AND SUBCONTRACTORS ARE RESPONSIBLE FOR THE ORDER AND MEANS OF CONSTRUCTION AND ALL TEMPORARY BRACING AND ERECTION DURING CONSTRUCTION. 9. APPROVALS BY BUILDING INSPECTORS SHALL NOT CONSTITUTE AUTHORITY TO DEVIATE FROM THE PLANS AND SPECIFICATIONS. 10. ALL WORK SHALL CONFORM TO TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR). 11. GRADING PLANS, DRAINAGE IMPROVEMENTS, ROAD AND ACCESS REQUIREMENTS AND ENVIRONMENTAL HEALTH CONSIDERATIONS SHALL COMPLY WITH ALL LOCAL ORDINANCES. 2/24/2023 7:37:03 PM Title Sheet FO S T E R P R I N T I N G C o 70 0 E A l t o n A v e Sa n t a A n a C A , 9 2 7 0 5 T101 FOSTER PRINTING Co 700 E Alton Ave Santa Ana CA, 92705 SOLAR ELECTRIC SYSTEM PROJECT - 455.220kW DC STC RATING / 422.677kW AC CEC RATING TIM BLACKBURN ADDRESS: 700 E ALTON AVE SANTA ANA, CA 92705 PHONE: 714-731-2000 SOLAR ELECTRIC SYSTEM THIS PROJECT ENTAILS THE INSTALLATION OF A PHOTOVOLTAIC SYSTEM AT FOSTER PRINTING Co THE SYSTEM WILL NOT BE A NET ELECTRICITY EXPORTER TO THE UTILITY GRID. This drawing is the property of RENEWABLE ENERGY PARTNERS. This information is confidential and is to be used only in connection with work described by RENEWABLE ENERGY PARTNERS. No part is to be discolosed to others without written permission from RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS LIC # 989857 EXP: 01/31/2024 RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS 170 MAPLE ST, STE 105 CORONA, CA 92881 TEL: 855-519-6633 LIC # 989857 RENEWABLE ENERGY PARTNERS www.RENEWEPI.com 855-519-6633 170 MAPLE ST, STE 105 CORONA, CA 92881 Sheet #Sheet Name T101 Title Sheet T102 Notes A101 Site Plan C-1.0 Cover Page M-1.0 Site Plan M-2.0 Roof Plan M-3.1 Load Array 1 M-3.2 Load Array 2 M-3.3 Load Array 3 M-3.4 Load Array 4 M-3.5 Load Array 5 M-4.0 Paver Layout M-4.1 Paver Array 1 M-4.2 Paver Array 2 M-4.3 Paver Array 3 M-4.4 Paver Array 4 M-4.5 Paver Array 5 E101 Electrical Layout E201 Single Line Diagram E301 Signage SP101 Spec Sheets SP102 Spec Sheets MODULES: (843) CSI SOLAR CO., LTD 540W SOLAR MODULES CS6W-540MB-AG PTC: 508 Wptc INVERTERS: (6) SUNGROW 60KW, INVERTERS SG60CX-US [480V] [SI1] CEC WEIGHTED EFFICIENCY: 98.5% RAPID SHUTDOWN SPECS: (432) TIGO TS4-A-2F ARRAY LOCATIONS PROJECT LOCATION PROJECT LOCATION APN:411-152-08 No . De s c r ip ti o n Da t e Bldg# 101114289 JLo Elec# 20179063 MSmith Issued 06/02/23 700 E Alton Ave - 101114289 & 2017906306/06/23 To scale on 24x36 paper X___________________________ Confidentiality Statement: 2/24/2023 7:38:10 PM Notes FO S T E R P R I N T I N G C o 70 0 E A l t o n A v e Sa n t a A n a C A , 9 2 7 0 5 T102 This drawing is the property of RENEWABLE ENERGY PARTNERS. This information is confidential and is to be used only in connection with work described by RENEWABLE ENERGY PARTNERS. No part is to be discolosed to others without written permission from RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS LIC # 989857 EXP: 01/31/2024 RENEWABLE ENERGY PARTNERS RENEWABLE ENERGY PARTNERS www.RENEWEPI.com 855-519-6633 170 MAPLE ST, STE 105 CORONA, CA 92881 ABBREVIATIONS ALTERNATING CURRENT APPROXIMATE AMERICAN WIRE GUAGE CENTER LINE COMBINER BOX DIRECT CURRENT DROP INLET DISCONNECT ELECTRICAL METALLIC TUBING (EXISTING) ELEVATION EQUAL INSIDE DIAMETER JUNCTION BOX MAIN COMBINER BOX MANUFACTURER MINIMUM MISCELLANEOUS (NEW) OR APPROVED EQUAL ON CENTER OUTSIDE DIAMETER POINT OF COMMON COUPLING PHOTOVOLTAIC PROPERTY LINE STORM DRAIN SQUARE FOOT/FEET SIMILAR TO BE DETERMINED TOP OF FOOTING TYPICAL UNLESS OTHERWISE NOTED VERIFY IN FIELD TRANSFORMER NOTES SYMBOLS AC APPROX AWG CL CB DC DI DISC EMT (E) EL EQ ID JB MCB MFR MIN MISC (N) OAE OC OD POCC PV PL SD SF SIM TBD TOF TYP UON VIF XFMR No . De s c r ip tio n Da t e 700 E Alton Ave - 101114289 & 2017906306/06/23