Loading...
HomeMy WebLinkAbout724 S Deming St - PlanNathan Draeger DESIGNER: DESIGN MGR: Nathan Draeger NEW PV SYSTEM: 5,600 DC / 3800 AC Ryan Achterberg 724 S Deming St, Santa Ana, CA 92704 APN: 10856202 4/30/2023 DATE:TIME: 05:01 PM REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: ELEC LOAD CALCS ELECTRICAL LOAD CALCULATIONS JURISDICTION STAMPS: P10BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 This item has been digitally signed and sealed on May 01, 2023 724 S Deming St - 2017951406/16/23 CS3N-400|405|410|415|420|425MS 400 W ~ 425 W CANADIAN SOLAR INC. is committed to providing high quality solar products, solar system solutions and services to cus- tomers around the world. No. 1 module supplier for quality and performance/price ratio in IHS Module Customer Insight Survey. As a leading PV project developer and manufacturer of solar modules with over 43 GW deployed around the world since 2001. * For detailed information, please refer to the Installation Manual. MORE POWER MORE RELIABLE Comprehensive LID / LeTID mitigation technology, up to 50% lower degradation Module power up to 425 W Module efficiency up to 21.2 %425 W Better shading tolerance Minimizes micro-crack impacts Up to 4.0 % lower LCOE Up to 4.2 % lower system cost Heavy snow load up to 5400 Pa, enhanced wind load up to 2400 Pa* HiKu5 Mono Dimensions: 1913 X 1048 X 35 mm (75.3 X 41.3 X 1.38 in) Weight: 22.0 kg (48.5 lbs) Max. System Voltage: 1500 V (IEC/UL) or 1000 V (IEC/UL) * As there are different certification requirements in different markets, please contact your local Canadian Solar sales representative for the specific certificates applicable to the products in the region in which the products are to be used. PRODUCT CERTIFICATES* CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1K 1E6, Canada, www.canadiansolar.com, support@canadiansolar.com ISO 9001:2015 / Quality management system ISO 14001:2015 / Standards for environmental management system OHSAS 18001:2007 / International standards for occupational health & safety MANAGEMENT SYSTEM CERTIFICATES* *According to the applicable Canadian Solar Limited Warranty Statement. 1st year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% 12 Years Years Enhanced Product Warranty on Materials and Workmanship* Linear Power Performance Warranty* 724 S Deming St - 2017951406/16/23 IN V E R T E R S solaredge.com Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Fixed voltage inverter for longer strings UL1741 SA certified, for CPUC Rule 21 grid compliance Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 Small, lightweight, and easy to install both outdoors or indoors Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEAR WARRANTY 724 S Deming St - 2017951406/16/23 MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)- - - -Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Single Phase Inverter with HD-Wave Technology for North America 724 S Deming St - 2017951406/16/23 Nathan Draeger DESIGNER: DESIGN MGR: Nathan Draeger NEW PV SYSTEM: 5,600 DC / 3800 AC Ryan Achterberg 724 S Deming St, Santa Ana, CA 92704 APN: 10856202 4/30/2023 DATE:TIME: 05:01 PM REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: Ryan Achterberg 724 S Deming St, Santa Ana, CA 92704 APN: 10856202 SYSTEM SIZE: 5,600 DC SYSTEM SIZE 3800 AC CEC POWER OUTPUT: 5167.4 CEC MODULE INFORMATION MODULE QTY: 14 MODULE MFG: Canadian Solar MODULE TYPE: CS3N-400MS [Blk] INVERTER INFORMATION INVERTER QTY: 1 INVERTER MFG: SOLAREDGE INVERTER TYPE: POWER OPTIMIZER INFORMATION OPTIMIZER QTY: 14 OPTIMIZER MFG: SOLAREDGE OPTIMIZER TYPE: S440 PROJECT DETAILS COVER SHEET P1 TABLE OF CONTENTS PAGE NUMBER: PAGE TITLE: P1 COVER SHEET P2 NOTES SHEET P3 SITE PLAN P4 ROOF PLAN P5 RACKING & FRAMING P6 LINE DIAGRAM & DESIGN TABLES P7 PLACARDS & PLACARD MAP P8 OPTIMIZER MAP P9 JOB HAZARD ANALYSIS SS00 SPECIFICATION PAGES RAILING INFORMATION RAILING MFG: UNIRAC RAILING TYPE: Unirac SM Light MOUNTING INFORMATION MOUNT FLASHING QTY: MOUNT FLASHING MFG: UNIRAC MOUNT FLASHING TYPE: 46 Unirac FlashLoc - Mill EXISTING SOLAR INFORMATION - N/A BATTERY INFORMATION - N/A ADDITIONAL SCOPE OF WORK JURISDICTION STAMPS: PROPERTY INFORMATION OWNER:Ryan Achterberg PHONE:1949-244-5668 EMAIL:rjachterberg11@gmail.com CONTRACTOR:BETTER EARTH ELECTRIC INC. PHONE: (888) 373-9379 AUTHORITIES HAVING JURISDICTION BUILDING: Santa Ana (CA) UTILITY: Southern California Edison DESIGN SPECIFICATIONS OCCUPANCY: R-3/U CONSTRUCTION: V-B NAME: RESIDENTIAL SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 130 MPH ROOF SURFACE: 2593 SQ.FT. PV SQ FOOTAGE: 306.39 PV COVERAGE: 11.82 % WEIGHT OF EQUIPMENT: 667.66 LBS WEIGHT PER ATTACHMENT: 14.51 LBS DISTRIBUTED WEIGHT: 2.18 PSF NO. OF STORIES: 1 FIRE SPRINKLERS: NO LOT INFORMATION APN: 10856202 LOT AREA: 6000 LIVING AREA: 1427 3800H-US Non-RGM BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 This item has been digitally signed and sealed on May 01, 2023 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101114925 Elec# 20179514 MSmith Issued 06/16/23 724 S Deming St - 2017951406/16/23 MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(3) Consumption metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown - NEC 2014, NEC 2017 and NEC 2020, 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14-6 AWG 1'' Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1-2 strings / 14-6 AWG 1'' Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(4)˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (3) Inverter with Revenue Grade Meter P/N: SExxxxH-US000BNC4; Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BNI4 . For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box (4) Full power up to at least 50˚C / 122˚F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2020/V01/ENG NAM. Subject to change without notice. 724 S Deming St - 2017951406/16/23 Rapid Shutdown Kit Installation - MAN-01-00186-1.6 1 Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) This document describes how to install the rapid shutdown kit in the SolarEdge Safety Switch, and how to enable the rapid shutdown feature in the inverter in order to provide the functionality described in the Rapid Shutdown clause of NEC2014 690.12 (1) through (4). Kit Contents ƒ Rapid shutdown cables ƒMicro-SD card and SD card adapter with firmware files (Note: DO NOT THROW AWAY THE CARD AND THE ADAPTER; keep them for installation of other rapid shutdown kits) Cable Installation Perform this procedure before connecting the strings to the Safety Switch [Chapter 4: Connecting the AC and the Strings to the Safety Switch in the SolarEdge Installation Guide]. 1 Turn the inverter ON/OFF switch to OFF. If installing the kit in an inverter that is already operating, wait until the LCD indicates that the DC voltage is safe (<50V), or wait five minutes before continuing to the next step. 2 Turn the Safety Switch and the AC switch on the main circuit board to OFF. WARNING! If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five minutes for the input capacitors of the inverter to discharge. 3 Loosen the four Allen screws on the front cover of the Safety Switch, and open the cover. 4 Carefully disconnect the two DC cables from the left side of the switch and from the DC connection spring clamp terminals, as illustrated below1. Use a standard straight-bladed screwdriver to disconnect the cables from the terminals. Figure 1: Inside the AC/DC Safety Switch 1 The internal components may vary depending on the Safety Switch model; the figures in this documents show the AC/DC Safety Switch for single phase 7.6-11.4 kW inverters. DC connection terminals Disconnect here Disconnect here Switch terminal block Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) Rapid Shutdown Kit Installation - MAN-01-00186-1.6 2 5 The rapid shutdown cables have a resistor connected to one end (on the red cable). Connect these ends to the switch, making sure that the red and black cables are reversed relative to the cables connected at the top of the switch (going into the DC side conduit between the inverter and the Safety Switch), as detailed below. Apply a torque of 2 N*m (18 lb*in): ƒ If the cables at the top are red and black from left to right, connect as shown below. Figure 2: Rapid shutdown cable connected – option 1 ƒIf the cables at the top are black and red from left to right, connect as shown below. Figure 3: Rapid shutdown cable connected – option 2 6 Use a standard straight-bladed screwdriver to connect the other end of the rapid shutdown cables to the DC connection spring-clamp terminals: Connect the black cable from the switch to the DC- terminal block, and connect the red cable from the switch to the DC+ terminal block. 7 Check that the cables are located and connected in the correct positions to ensure the rapid shutdown functionality. 8 Close the cover: Attach the switch cover and secure it by tightening the four screws with a torque of 0.9 ft.*lb / 1.2 N*m. Red (+) Black (-) Black (-) DC+ DC- Red (+) with rapid shutdown resistor Black (-) Red (+) Black (-)BlaRed (+) with rapid shutdown resistor DC+ DC- 724 S Deming St - 2017951406/16/23 solaredge.com Power Optimizer For Residential Installations S440 / S500 / S500B Enabling PV power optimization at the module level Specifically designed to work with SolarEdge residential inverters Detects abnormal PV connector behavior, preventing potential safety issues* Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading Faster installations with simplified cable management and easy assembly using a single bolt Flexible system design for maximum space utilization Compatible with bifacial PV modules PO W E R O P T I M I Z E R 2 5 YEAR WARRANTY * Functionality subject to inverter model and firmware version 724 S Deming St - 2017951406/16/23 © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: November 8, 2022 DS-000091-ENG. Subject to change without notice. Power Optimizer For Residential Installations S440 / S500 / S500B S440 S500 S500B UNIT INPUT Rated Input DC Power(1) 440 500 W Absolute Maximum Input Voltage (Voc) 60 125 Vdc MPPT Operating Range 8 – 60 12.5 – 105 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERTION Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE(2) EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2018-12 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 155 x 30 129 x 155 x 45 mm Weight (including cables) 655 gr Input Connector MC4(3) Input Wire Length 0.1 m Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 m Operating Temperature Range(4) -40 to +85 ˚C Protection Rating IP68 Relative Humidity 0 – 100 % (1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed. (2) For details about CE compliance, see Declaration of Conformity – CE. (3) For other connector types please contact SolarEdge. (4) For ambient temperatures above +70°C power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for details. PV System Design Using a SolarEdge Inverter(5) SolarEdge Home Wave Inverter Single Phase SolarEdge Home Short String Inverter Three Phase Three Phase for 230/400V Grid Three Phase for 277/480V Grid Minimum String Length (Power Optimizers) S440, S500 8 9 16 18 S500B 6 8 14 Maximum String Length (Power Optimizers )25 20 50 Maximum Continuous Power per String 5700 5625 11250 12750 W Maximum Allowed Connected Power per String (Permitted only when the power difference between strings is less than 2,000W) See(6)See(6)13500 15000 W Parallel Strings of Different Lengths or Orientations Yes (5) It is not allowed to mix S-series and P-series Power Optimizers in new installations. (6) If the inverter’s rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to Application Note: Single String Design Guidelines. * 45mm for S500B 724 S Deming St - 2017951406/16/23 FLASHLOC is the ultimate attachment for composition shingle and rolled comp roofs. The all-in-one mount installs fast — no kneeling on hot roofs to install flashing, no prying or cutting shingles, no pulling nails. Simply drive the lag bolt and inject sealant into the base. FLASHLOC’s patented TRIPLE SEAL technology preserves the roof and protects the penetration with a permanent pressure seal. Kitted with lag bolts, sealant, and hardware for maximum convenience. Don’t just divert water, LOC it out! PROTECT THE ROOF Install a high-strength waterproof attachment without lifting, prying or damaging shingles. FLASH LOC LOC OUT WATER With an outer shield 1 contour-conforming gasket 2 and pressurized sealant chamber 3 the Triple Seal technology delivers a 100% waterproof connection. Cut Away View HIGH-SPEED INSTALL Simply drive lag bolt and inject sealant into the port 4 to create a permanent pressure seal. Cut Away View FASTER INSTALLATION. 25-YEAR WARRANTY. FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 3 2 4 1 TESTED TO TAS-100 WIND DRIVEN RAIN TEST AND UL441 RAIN TEST 724 S Deming St - 2017951406/16/23 FASTER INSTALLATION. 25-YEAR WARRANTY. FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 FLASH LOC INSTALLATION GUIDE STEP 1: SECURE Place FLASHLOC over pilot hole with lag on down-slope side. Align indicator marks on sides of mount with chalk line. Pass included lag bolt and sealing washer through FLASHLOC into pilot hole. Drive lag bolt until mount is held firmly in place. NOTE: The EPDM in the sealing washer will expand beyond the edge of the metal washer when proper torque is applied. PRE-INSTALL Snap chalk lines for attachment rows. On shingle roofs, snap lines 1-3/4” below upslope edge of shingle course. Locate rafters and mark attachment locations. At each location, drill a 7/32” pilot hole. Clean roof surface of dirt, debris, snow, and ice. Next, BACKFILL ALL PILOT HOLES WITH SEALANT. NOTE: Space mounts per racking system install specifications. STEP 2: SEAL Insert tip of UNIRAC provided sealant into port. Inject until sealant exits both vents. Continue array installation, attaching rails to mounts with provided T-bolts. NOTE: When FLASHLOC is installed over gap between shingle tabs or vertical joints, fill gap/joint with sealant between mount and upslope edge of shingle course. NOTE: When installing included rail attachment hardware, torque nut to 30 ft/lbs. USE ONLY UNIRAC APPROVED SEALANTS: Chemlink Duralink 50 (included in kit) or Chemlink M-1 SEALANT GAP 1.75" 724 S Deming St - 2017951406/16/23 LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART DRAWING 4/28/2020 FLASHLOC COMP KIT REVISION DATE: DRAWING TYPE: DESCRIPTION: FL - A 0 1 PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART TABLE P/N DESCRIPTION 004085M FLASHLOC COMP KIT MILL, 20 PACK 004085D FLASHLOC COMP KIT DARK, 20 PACK 67 8 " 31 2 " 33 4" 21 4 " 5/16" x 4" SS LAG BOLT W/ SS EPDM BONDED WASHER SS SERRATED T-BOLT FLASHLOC BASE MILL OR DARK SS SERRATED FLANGE NUT 724 S Deming St - 2017951406/16/23 SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with revolutionary universal clamps, FLASHKIT PRO, full system UL 2703 certification and 25-year warranty. Not only is SOLARMOUNT easy to install, but best-in-class aesthetics make it the most attractive on any block! NOW FEATURING FLASHKIT PRO The Complete Roof Attachment Solution NOW WITH UNIVERSAL MIDCLAMPS Accommodates 30mm-51mm module frames One tool, one-person installs are here! REVOLUTIONARY NEW ENDCLAMPS Concealed design and included End Caps THE PROFESSIONALS’ CHOICE FOR RESIDENTIAL RACKING BEST INSTALLATION EXPERIENCE • CURB APPEAL • COMPLETE SOLUTION • UNIRAC SUPPORT SOLARMOUNT OPTIONAL FRONT TRIM New & Improved: THE PROFESSIONALS’ CHOICE With Superior Aesthetics CONCEALED UNIVERSAL CLAMPS 25 YEAR FULL-SYSTEM WARRANTY FOR QUESTIONS OR CUSTOMER SERVICE VISI T UNIRAC.COM OR CALL (505) 248-2702 724 S Deming St - 2017951406/16/23 UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT ENGINEERING EXCELLENCE UNMATCHED EXPERIENCE PERMIT DOCUMENTATION DESIGN TOOLS CERTIFIED QUALITY BANKABLE WARRANTY BETTER DESIGNS TRUST THE INDUSTRY’S BEST DESIGN TOOL Start the design process for every project in our U-Builder on-line design tool. It’s a great way to save time and money. BETTER SYSTEMS ONE SYSTEM - MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs. Orient a large variety of modules in Portrait or Landscape. Tilt the system up on flat or low slow roofs. Components available in mill, clear, and dark finishes to optimize your design financials and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB Trust Unirac to help you minimize both system and labor costs from the time the job is quoted to the time your teams get off the roof. Faster installs. Less Waste. More Profits. BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers. You have access to our technical support and training groups. Whatever your support needs, we’ve got you covered. Visit Unirac.com/solarmount for more information. UNIVERSAL SELF STANDING MIDCLAMPS U-BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEY Visit design.unirac.com BANKABLE WARRANTY Don’t leave your project to chance, Unirac has the financial strength to back our products and reduce your risk. Have peace of mind knowing you are providing products of exceptional quality. SOLARMOUNT is covered by a 25 year limited product warranty and a 5 year limited finish warranty. TECHNICAL SUPPORT Unirac’s technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly simplifies your permitting and project planning process. CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO certifications for 9001:2008, 14001:2004 and OHSAS 18001:2007, which means we deliver the highest standards for fit, form, and function. These certifications demonstrate our excellence and commitment to first class business practices. UL2703BONDING & GROUNDING MECHANICAL LOADING SYSTEM FIRE CLASSIFICATIONL I S T E D SOLARMOUNT CONCEALED UNIVERSAL ENDCLAMPS END CAPS INCLUDED WITH EVERY ENDCLAMP ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN FOR Q UE S TI ON S OR C US TOME R S E R VI C E VI S I T UN I R A C . C OM OR C A LL (5 0 5 ) 2 48 -2 7 0 2PUB2018AUG31 – PRINTED UPDATE 724 S Deming St - 2017951406/16/23 Nathan Draeger DESIGNER: DESIGN MGR: Nathan Draeger NEW PV SYSTEM: 5,600 DC / 3800 AC Ryan Achterberg 724 S Deming St, Santa Ana, CA 92704 APN: 10856202 4/30/2023 DATE:TIME: 05:01 PM REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: NOTES SHEET P2 1. RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURES SPECIFICATIONS AND THE 2022 CALIFORNIA RESIDENTIAL CODE, SECTIONS R314, R909 AND R918, 2022 CALIFORNIA ELECTRICAL CODE AND 2022 CALIFORNIA FIRE CODE. 2. CONTRACTORS SHALL BE PRESENT DURING ALL INSPECTIONS. 3. THE ROOF ACCESS POINT REQUIRING A LADDER SHALL NOT BE LOCATED OVER A WINDOW, DOOR OR LOCATED WHERE IT CONFLICTS WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS [CRC 324.7.1]. 4. A LADDER SHALL BE PROVIDED AND SECURED TO THE STRUCTURE AT THE APPROVED ROOF ACCESS POINT PER NOT "C" ABOVE WITH A CAL OSHA APPROVED DEVICE DURING ALL INSPECTIONS. 5. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATION'S INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 6. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] 7. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 8. CONTACT THE SERVICING UTILITY BEFORE POWERING ON THE PHOTOVOLTAIC SYSTEM 9. ALL WORK SHALL COMPLY WITH APPLICABLE, LOCAL, MUNICIPAL CODES, AND TO MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. THE PV SOLAR SYSTEM WILL BE INTERCONNECTED AND OPERATED IN PARALLEL WITH THE UTILITY ELECTRICAL GRID PER THE REQUIREMENTS OF THE UTILITY AND APPLICABLE CODES. THE PV SOLAR SYSTEM IS DESIGNED IN COMPLIANCE WITH CEC 690.12 (RAPID SHUTDOWN). JURISDICTION NOTES ELECTRICAL NOTES CONSTRUCTION NOTES UTILITY NOTES 1. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. 3. ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4. THE SOLAR INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING OR MECHANICAL VENTS. 5. A LADDER WILL BE IN PLACE FOR INSPECTIONS IN COMPLIANCE WITH CAL OSHA REGULATIONS. 6. MODULE MOUNTING STRUCTURE WILL BE TIED DIRECTLY INTO STRUCTURAL ELEMENTS OF SINGLE FAMILY DWELLING ROOF TRUSSES / RAFTERS OR BEAMS ACCORDING TO MOUNTING STRUCTURE DIRECTIONS. 7. ROOF COVERING PENETRATIONS SHALL BE DESIGNED, INSTALLED AND MAINTAINED IN ACCORDANCE WITH BUILDING CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGS SHALL SERVE TO PROTECT THE BUILDING STRUCTURE. 8. CONDUIT, WIRING SYSTEMS AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY AS DIRECTLY AS POSSIBLE TO POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. 9. WE WILL MAINTAIN 6" CLEARANCE FROM ALL VENTS AND OBSTRUCTIONS. 10. CONDUIT RUNS TO BE DETERMINED IN FIELD 1. PV SOURCE CIRCUIT(S) ARE TO BE SUNLIGHT-RESISTANT PV-WIRE AS PERMITTED BY CEC 690.31(B). 2. ALL DIRECT CURRENT CIRCUITS ARE TO BE INSTALLED IN METAL RACEWAY FROM THE POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE MAIN SERVICE PANEL AS MANDATED BY CEC 690.31(E). 3. WEATHERPROOF J-BOX – NEMA 3R. 4. ROOFTOP CONDUIT SHALL BE A MINIMUM OF 1" ABOVE THE ROOF SURFACE. 5. ALL WORK SHALL COMPLY WITH THE 2022 CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL OTHER LOCAL CODES AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. CODE REFERENCES · 2022 CALIFORNIA BUILDING CODE · 2022 CALIFORNIA RESIDENTIAL CODE · 2022 CALIFORNIA ELECTRICAL CODE · 2022 CALIFORNIA FIRE CODE · 2022 CALIFORNIA MECHANICAL CODE · 2022 CALIFORNIA GREEN CODE · 2022 CALIFORNIA PLUMBING CODE · 2022 CALIFORNIA ENERGY CODE · ANY OTHER LOCAL AND MUNICIPAL CODES GENERAL NOTES UTILITY HAS 24 HR UNRESTICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT SERVICE ENTRANCE WORKSPACE IN FRONT OF AC ELECTRICAL SYSTEM COMPONENTS SHALL BE IN ACCORDANCE WITH APS AND NEC REQUIREMENTS. FOR APS REQUIREMENTS, REFERENCE SECTION 300 OF THE APS ESRM AND SECTION 8.2 OF THE APS INTERCONNECTION REQUIREMENTS REFERENCE SECTION 301.15 OF THE APS ESMR FOR ELECTRIC METER SEPERATION BETWEEN WATER AND GAS JURISDICTION STAMPS: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 This item has been digitally signed and sealed on May 01, 2023 724 S Deming St - 2017951406/16/23 SITE PLAN N P3 NEW PV SYSTEM: 5,600 DC / 3800 AC Ryan Achterberg 724 S Deming St, Santa Ana, CA 92704 APN: 10856202 DRAWING TITLE: DRAWING PAGE: SCALE:1/16" = 1' JURISDICTION STAMPS: FIRE CODE PATHWAY BACKUP INTERFACE BACKUP GATEWAYBG BI MODULE STRINGING 3 4" EMT CONDUIT OPTIMIZER JB JUNCTION BOX LEGEND CALLOUTS: 1 1 4" PVC TRENCH COMBO METER/MAINMM UTILITY METERUM MAIN SERVICE PANEL PV METER MSP PV INVERTER SUB PANEL INV SUB AC DISCONNECT AC COMBINER PANELACL AC EV CHARGER BATTERY BACKUP EV BB BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 MM ACLAC INV AC INV (E) 200A MAIN SERVICE PANEL (E)E) DRIVE (E)E) PROPERTY L 724 S D E M I N G S T , S A N T A AN A , C A 9 2 7 04 (N)SOLAREDGE 3800H-US Non-RGM INVERTER (N) AC LOAD CENTER (N)30A AC DISCONNECT EXISTING PV SYSTEM (E)26 REC275TP BLK MODULES (E)SE6000A INVERTER EXISTING PV SYSTEM (E)26 REC275TP BLK MODULES ARRAY 2 - (N)6 Canadian Solar MODULES TILT:14° AZIMUTH: 270° ARRAY 3 - (N)2 Canadian Solar MODULES TILT:14° AZIMUTH: 90° ARRAY 1 - (N)6 Canadian Solar MODULES TILT: 14° AZIMUTH: 360° ROOF ACCESS POINT PER CRC 2022 (R324.6) NOT POWERED PATIO COVER 1 Nathan Draeger DESIGNER: DESIGN MGR: Nathan Draeger 4/30/2023 DATE:TIME: 05:01 PM REVISION:DATE:DESCRIPTION: 1 05/10/23 AHJ CORRECTIONS 724 S Deming St - 2017951406/16/23 MM ACLACINV AC INV Nathan Draeger DESIGNER: DESIGN MGR: Nathan Draeger NEW PV SYSTEM: 5,600 DC / 3800 AC Ryan Achterberg 724 S Deming St, Santa Ana, CA 92704 APN: 10856202 4/30/2023 DATE:TIME: 05:01 PM REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE:3/32" = 1' N ARRAY 1: MODULE QTY: 6 TILT: 14° AZIMUTH: 360° MATERIAL: Comp Asphalt Shingles ARRAY 2: MODULE QTY: 6 TILT: 14° AZIMUTH: 270° MATERIAL: Comp Asphalt Shingles ARRAY 3: MODULE QTY: 2 TILT: 14° AZIMUTH: 90° MATERIAL: Comp Asphalt Shingles ROOF PLAN P4 ROOF DETAILS:JURISDICTION STAMPS: FIRE CODE PATHWAY BACKUP INTERFACE BACKUP GATEWAYBG BI MODULE STRINGING 3 4" EMT CONDUIT OPTIMIZER JB JUNCTION BOX LEGEND CALLOUTS: 1 1 4" PVC TRENCH COMBO METER/MAINMM UTILITY METERUM MAIN SERVICE PANEL PV METER MSP PV INVERTER SUB PANEL INV SUB AC DISCONNECT AC COMBINER PANELACL AC EV CHARGER BATTERY BACKUP EV BB CONDUIT RUN TO BE DETERMINED IN FIELD BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 REQUIRED ROOF ACCESS POINT PER CRC 2022 SECTION R324.6 LADDER ACCESS SHALL BE AT STRONG POINT OF ROOF AND NOT OVER REQUIRED WINDOW OPENINGS.This item has been digitally signed and sealed on May 01, 2023 724 S Deming St - 2017951406/16/23 FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE Comp Asphalt Shingles 48" 2x6 TRUSS @24" O.C. SOLAR MODULES 7/16 X 3/4" NUT, FLANGE UNIRAC STANDARD RAIL 3/8" BOLT(E) COMPOSITION SHINGLE (E) ROOF SHEATHING TYP. PLACE SEALANT AROUND LAG BOLT AND UNDER STANDOFF BASE PREDRILLED 3/16" HOLE (1) 5/16" STAINLESS STEEL LAG BOLT W/ 2-1/2" MIN. EMBEDMENT (E) ROOF FRAMING TYP. 6" M A X UNIRAC COMP SHINGLE ATTACHMENT E 2x6 TRUSS TYPICAL WITH PRONGED TRUSS PLATE EITHER SIDE OF ALL JOINTS TYPICAL SOLA R M O D U L E S Nathan Draeger DESIGNER: DESIGN MGR: Nathan Draeger NEW PV SYSTEM: 5,600 DC / 3800 AC Ryan Achterberg 724 S Deming St, Santa Ana, CA 92704 APN: 10856202 4/30/2023 DATE:TIME: 05:01 PM REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: RACKING & FRAMING DETAILS P5 TYPICAL ROOF ATTACHMENT PLAN ATTACHMENT DETAILFRONT VIEW TYP FRAMING DETAIL JURISDICTION STAMPS: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 This item has been digitally signed and sealed on May 01, 2023 724 S Deming St - 2017951406/16/23 STRING 1: (14x) Canadian Solar CS3N-400MS [Blk] PV MODULES WITH 14 S440 SE POWER OPTIMIZERS 1 JUNCTION BOX - NEMA 3R AS REQUIRED 2 INVERTER SOLAREDGE SE3800H-US NON-RGM WITH DC DISCONNECT PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER NEC 690.12 3+ - + - + - + - + - + - 1421 DC AC POINT OF INTERCONNECTION LOAD SIDE 705.12(B)(3)(2) MAIN (N) 175A (N) 60A M BI-DIRECTIONAL UTILITY METER 1PH/240V (E) 200A/(N)175A MAIN SERVICE PANEL 240/120v 1-PH, 3-W MAIN BONDING JUMPER MAX BREAKER CALC.: 200A X 1.2 - 175A = 65A TO UTILITY GRID (Overhead) (N) AC COMBINER PANEL 240/120 V 1Ø, 3W MAX MAIN BUS: 125A (N) 20A (E) 35A TO (E) SOLAR SYSTEM 4 VISIBLE/ LOCKABLE AC DISCONNECT 60A AC NON-FUSED 240V, NEMA3R 4 (E) GROUNDING ELECTRODE (COPPER) GROUND ROD TO (E) SOLAR BREAKER EXISTING PV SYSTEMDETAILS(26) REC275TP BLK MODULES (1) SE6000A (240) INVERTER ROOFTOP JUNCTION BOX INVERTERS 60A NON-FUSED AC DISCONNECT CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID CONDUCTOR CONDUIT CURRENT-CARRYING CONDUCTORS IN CONDUIT EGC TEMP. CORR. FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING 1 2 3 #10 PV Wire, in open air 3/4" EMT N/A #6 51 15 18.75 40 38.4 90 #10 THWN-2, in conduit 3/4" EMT 2 #8 51 15 18.75 40 38.4 75 #10 THWN-2, in conduit 3/4" EMT 3 #8 32 16 20 40 38.4 75 4 #6 THWN-2, in conduit 3/4" EMT 3 #8 32 41 51.25 65 61.1 75 ASHRAE EXTREME LOW DESIGN TEMPERATURES ASHRAE 2% HIGH 32°C 32°C INVERTER 1 SPECS SOLAREDGE 3800H-US_Non-RGM AC VOLTAGE (V) 240 GROUND 0.99 MAX OCPD (A) 20 RATED POWER (W) 3800 MAX OUTPUT (A) 16 MAX INPUT (A) 11 MAX INPUT (V) 480 EFFICIENCY (CEC) 0.99 POWERBOX MAX OUTPUT CURRENT OPTIMIZERS IN SERIES NOMINAL STRING VOLTAGE ARRAY OPERATING CURRENT STRING DETAILS INVERTER 1 STRING CALCULATIONS STRING 1 15A 14 380V 16A SYSTEM SUMMARY ARRAY STC POWER 5600W ARRAY PTC POWER 5167.4W MAX AC CURRENT 16A MAX AC POWER 3800W INVERTER 1MODULE SPECS Canadian Solar CS3N-400MS [Blk] PMAX (W) 400 PTC (W) 369.1 ISC (A) 11.5 IMP (A) 10.76 VOC (V) 44.5 VMP (V) 37.2 TEMP. COEFF. OF VOC -0.122 POWER OPTIMIZERS RATED INPUT (W) MAX INPUT ISC (A) WEIGHTED EFFICIENCY MAX OUTPUT(A) MAX DC (V) SOLAREDGE S440 Optimizer 440 15 98.6 15 60 Nathan Draeger DESIGNER: DESIGN MGR: Nathan Draeger NEW PV SYSTEM: 5,600 DC / 3800 AC Ryan Achterberg 724 S Deming St, Santa Ana, CA 92704 APN: 10856202 4/30/2023 DATE:TIME: 05:01 PM REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: LINE DIAGRAM & DESIGN TABLES P6 JURISDICTION STAMPS: EQUIPMENT SPECS NOTES: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 This item has been digitally signed and sealed on May 01, 2023 724 S Deming St - 2017951406/16/23 POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN CAUTION: MULTIPLE SOURCES OF POWER SERVICE BY QUALIFIED PERSONNEL ONLY N 724 S DEMING ST, SANTA ANA, CA 92704 Nathan Draeger DESIGNER: DESIGN MGR: Nathan Draeger NEW PV SYSTEM: 5,600 DC / 3800 AC Ryan Achterberg 724 S Deming St, Santa Ana, CA 92704 APN: 10856202 6. 5. 2023 DATE:TIME: 05:36 AM REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: ROOFTOP PV ARRAY UTILITY METER AND MAIN SERVICE PANEL PLACARD & PLACARD MAP P7 LABELING PLAN PROPERTY MAP NOTES: FORMAT 1. WHITE LETTERING ON A RED BACKGROUND 2. MINIMUM 3/8 INCHES LETTER HEIGHT 3. ALL LETTERS SHALL BE CAPITALIZED 4. ARIAL OR SIMILAR FONT (NON-BOLD) 6"X6" DISCONNECT DIRECTORY PLAQUE INSTALL AT MAIN SERVICE PANEL MATERIAL REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS JURISDICTION STAMPS: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 YOU ARE HERE INVERTER INVERTERAC DISCONNECT AC DISCONNECT AC COMBINER STICKER LOCATED INSIDE PANEL NEXT TO PV BREAKER 11 [CEC 690.14(C)(2)] PLACE ON AC DISCONNECT 8 9 [CEC 705.12(B)(2)(3)(C)] PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT LABELING NOTES: 1.1 LABELING REQUIREMENTS BASED ON THE NATIONAL ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535. 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. PHOTOVOLTAIC SOLAR BREAKER PHOTOVOLTAIC AC DISCONNECT ! WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS 10 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [CEC 690.56(C)(1)(A)] 2 3 [CEC 690.53] AT EACH DC DISCONNECT MEANS [CEC 690.5(C)] PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION 1 [CEC 690.31(G)3 & 4] PLACE ON JUNCTION BOXES AND CONDUIT EVERY 10' WARNING: PHOTOVOLTAIC POWER SOURCE ! MAXIMUM VOLTAGE PHOTOVOLTAIC SYSTEM DC DISCONNECT ! MAX CIRCUIT CURRENT 15 AMPS ! TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ELECTRIC SHOCK HAZARD WARNING MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-DC CONVERTER 4 [CEC 690.12(5)] PLACE ON INVERTER PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN 7 6 5 [CEC 690.54] PLACE LABEL AT "INTERACTIVE POINT OF INTERCONNECTION" (AT MAIN SERVICE PANEL AND SUBPANEL IF APPLICABLE) [CEC 690.64(B)(4)] PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES ! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY WARNING ! RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE 240 V PHOTOVOLTAIC SYSTEM AC DISCONNECT ! ! DO NOT RELOCATE THIS OVERCURRENT DEVICE INVERTER OUTPUT CONNECTION WARNING 16A 480 VDC 16 AMPS CEC 705.12(B)(2)(3)(B) PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL AND SUBPANEL IF APPLICABLE) SUB PANEL 5 6 JUNCTION BOX METER MAIN SERVICE PANEL 1 7 6 8 10 9 INVERTER INTEGRATED DC DISCONNECT 4 2 3 1 WHEN APPLICABLE AC DISCONNECT PRODUCTION METER AC DISCONNECT ROOFTOP ARRAY AC LOAD CENTER 73 5 8 3 5 83 5 5 11 WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE PRODUCTION METER WHEN APPLICABLE 724 S Deming St - 2017951406/16/23 Nathan Draeger DESIGNER: DESIGN MGR: Nathan Draeger NEW PV SYSTEM: 5,600 DC / 3800 AC Ryan Achterberg 724 S Deming St, Santa Ana, CA 92704 APN: 10856202 4/30/2023 DATE:TIME: 05:01 PM REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 42 34 43 35 44 36 45 37 46 38 47 39 48 40 49 41 50 OPTIMIZER MAP P8 SYSTEM SIZE 5600 W DC MODULE TYPE Canadian Solar CS3N-400MS [Blk] MODULE QTY 14 INVERTER TYPE SOLAREDGE 3800H-US Non-RGM INVERTER INVERTER QTY 1 POWER OPTIMIZER TYPE SOLAREDGE S440 POWER OPTIMIZER POWER OPTIMIZER QTY 14 SYSTEM DETAILS 52 53 54 56 57 58 60 61 62 64 65 66 68 69 70 71 72 73 74 75 76 77 78 51 55 59 63 67 BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 724 S Deming St - 2017951406/16/23 H HAZARD A ANCHOR POINT LEGEND L LADDER E ENTRY / EXIT WORK ANGLE ELECTRICAL ZONE WORK ZONE JOB HAZARD ANALYSIS Use the space below to draft a JHA. Be sure to include all indicators found in the Legend. NEAREST MEDICAL FACILITY: NAME: PHONE: ADDRESS: 1 1 4" PVC TRENCH Nathan Draeger DESIGNER: DESIGN MGR: Nathan Draeger NEW PV SYSTEM: 5,600 DC / 3800 AC Ryan Achterberg 724 S Deming St, Santa Ana, CA 92704 APN: 10856202 4/30/2023 DATE:TIME: 05:01 PM REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: JOB HAZARD ANALYSIS P9 CREW LEAD: CREW: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 (E) DRIVEWAY (E) ENTRANCE 724 S Deming St - 2017951406/16/23 Digitally sealed by RJM on Date: Job #: 23-08189 E.O.R.: Ryan McPherson, P.E. 9240 Limonite Ave Jurupa Valley, CA 92509 Mobile: (909) 566-0066 Email: SE@mcpe.group 5/1/23 Structural Analysis Report For Photovoltaic System Addition to Existing Structure At The Achterberg Residence 724 S Demming St Santa Ana , CA 92704 5/1/23 Designed in Accordance with CBC 2022, ASCE 7-16 5/1/2023 2:01 PM 1 of 7 ©McPherson Engineering 724 S Deming St - 2017951406/16/23 McPherson Engineering By: T.B. Date: 5/1/23 Project Info 3 Gravity Loads 4 Lateral Loads 5 Wind Uplift Design 6 Summary 7 Table Of Contents *Note: This engineering report is limited to the information presented to Engineer via plans, site information, photos, and written correspondence as provided by Client. On-site structural observations and verification of site conditions are not included herein. Engineering for manufactured products such as photovoltaic modules or racking systems is excluded from this report. Please refer to the manufacturer's specifications, certifications, and pre-engineered packages for product engineering. Installations of solar modules and related equipment must be performed in accordance with manufacturer recommendations, local codes, local regulations, industry best practices, and applicable safety standards. Owner and/or Contractor shall notify Engineer should any damage, deterioration, or descrepancies between current condition of the structure or otherwise as this letter describes before proceding with construction. This letter applies only to regions of the structure where solar modules will be supported and the supporting elements. 5/1/2023 2:01 PM 2 of 7 ©McPherson Engineering 724 S Deming St - 2017951406/16/23 McPherson Engineering By: T.B. Date: 5/1/23 Location: 724 S Demming St Santa Ana , CA 92704 Existing Structure Info: Number of Stories = 1 Aroof = 2500 sq. ft. Roof Square Footage A3rd_flr = 0 sq. ft. Third Floor Square Footage (if applicable) A2nd_flr = 0 sq. ft.Second Floor Square Footage (if applicable) Site Properties: Lattitude = Longitude = Ss = 1.337 S1 = 0.478 Exposure Category = C Ult. Wind Speed = 130 m.p.h. P.V. Array Info: Model = CS3N-400MS Height of Panel = 76.40 in. Width of Panel = 41.30 in. Area of Panel = 21.9 ft.2 Number of New Panels = 14 Number of Exis. Panels = 26 Total Area of Array = 876.5 ft.2 Spacing of Anchors = 4.0 ft. max. on center rows of racks per panel = 2 Panel Tilt = 7-27 deg 33.737295 -117.941286 Project Info 5/1/2023 2:01 PM 3 of 7 ©McPherson Engineering 724 S Deming St - 2017951406/16/23 McPherson Engineering By: T.B. Date: 5/1/23 Existing Loads: Roof Design Loads: Roofing = 4.0 p.s.f.Composition roofing Sheathing = 1.5 p.s.f.1/2" Plywood Framing = 1.5 p.s.f.2x Framing Misc = 3.0 p.s.f. DLr1 = 10.0 p.s.f.Roofing Dead Load (applied to top of rafters/trusses only) Ceiling = 2.0 p.s.f. Drywall and framing DLr2 = 12.0 p.s.f. Total Existing Roof Dead Load LLr = 20.0 p.s.f. Roof Live Load (Per C.B.C, Table 1607.1) SL = 0.0 p.s.f.Snow Load Floor Design Loads: (if applicable) Flooring = 10.0 p.s.f.Weight of floor finish Sheathing = 2.2 p.s.f.3/4" plywood Framing = 2.0 p.s.f.2x framing or manufactured floor truss Interior Partitions = 15.0 p.s.f.2x framed walls with drywall finish each side Ceiling = 5.0 p.s.f.Drywall ceiling finish below Misc. = 0.8 p.s.f. DLf = 35.0 p.s.f.Total Existing Floor Dead Load Proposed Loads: Panels = 2.9 p.s.f. weight of panels including rack system DLr1_proposed = 12.9 p.s.f. Proposed Roof Dead Load (applied to top only) DLr2_proposed = 14.9 p.s.f.Total Proposed Roof Dead Load LLr_proposed = 0.0 p.s.f. Check Proposed Gravity Loads: Total Existing Roof Load Wex = (DLr1 + LLr) (Aroof) = 75.0 kips Total Proposed Roof Load Wprop = (DLr1 + LLr) (Aroof - Aarray) + (DLr1_proposed + LLr_proposed) (Aarray) = 60.0 kips Proposed Load Demand Gravity Loads Roof Live Loads need not be applied to the area covered with by PV panel where the clear space between the panels and the roof sureface is 24in or less, 1607.13.5.1 item 1 Exception Wprop - Wex = -20.04% TOTAL DECREASE IN GRAVITY LOADS, PANELS OK! Wex 5/1/2023 2:01 PM 4 of 7 ©McPherson Engineering 724 S Deming St - 2017951406/16/23 McPherson Engineering By: T.B. Date: 5/1/23 Seismic Design Parameters Risk Category = 2 Per Table 1-5-1 R = 6.5 Response Modification Factor (Table 12-2.1) Site Class = D Per 11.4.2 Ie = 1 Seismic Importance Factor (Table 1.5-2) Ss = 1.34 Short Period P.G.A. S1 = 0.48 1-Sec Period P.G.A. S.D.C. = D Seismic Design Category Per 11.6 Fa = 1.20 Site Coefficient per Table 11.4-1 ASCE 7-16 Supplement #1 Tables used for Fa and Fv Fv = 1.70 Site Coefficient per Table 11.4-2 (note: section 11.4.8 Exception #2 calc used) SMS = SDS Fa = 1.60 Short Period M.C.E. Per Eq. 11.4-1 SM1 = SD1 Fv = 0.81 1-Sec Period M.C.E. Per Eq. 11.4-2 SDS = 2/3 (SMS) = 1.07 Short Period Design Parameter Per Eq 11.4-3 SD1 = 2/3 (SM1) = 0.54 1-Sec Period Design Parameter Per Eq 11.4-4 Approximate Fundamental Period (Per 12.8.2.1) per Eq. 12.8-7 hn = 15 ft Ct = 0.02 (per table 12.8-2) x = 0.75 (per table 12.8-2) T = 0.15 sec Approximate Fundamental Period TL = 8 sec Long-Period Transition Period per Figure 22-12 Seismic Response Coefficient (Per 12.8.1.1) CS = (SDS Ie)/R = 0.16 Seismic Response Coefficient Per Eq. 12.8-2 Cs1 = 1.5*(SD1 Ie)/R T = 0.82 Max. Seismic Response Coefficient Per Eq. 12.8-3 if T ≤ TL Cs2 = 0.01 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs2 = 0.044 SDS Ie = 0.05 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs3 = 0.5 S1 Ie/R = 0.04 Min. Seismic Response Coefficient Per Eq. 12.8-6 if S 1 ≥ 0.6g CS = 0.16 Design Seismic Coefficient Check Additional Base Shear Wexisting = 30.0 kips Weight of Existing Structure Wpanels = 2.5 kips Weight of Proposed Panels Vexisting = Cs Wexisting = 4.9 kips Roof Level Shear of Existing Structure Vpanels = Cs Wpanels = 0.4 kips Additional Roof Level Shear of Proposed Panels Vpanels Vexisting Lateral Loads T = Ct (hn) x = 8.34% < 10%PER C.E.B.C. 502.5 EXCEPTION, STRUCTURE DOES NOT REQUIRE SEISMIC RETROFIT, PANELS OK! 5/1/2023 2:01 PM 5 of 7 ©McPherson Engineering 724 S Deming St - 2017951406/16/23 McPherson Engineering By: T.B. Date: 5/1/23 Rooftop Solar Panels Wind Pressures (Section 29.4, ASCE 7-16) Vult = 130 mph Kzt = 1.00 (sec 26.8.2) h = 15 ft Exposure Category = C Kz = 0.85 (sec 26.10.1) Roof Zone = 2 Kd = 0.85 (sec 26.6) Roof θ = 7-27 deg Ke = 1.00 (sec 26.9) qh = 0.00256 Kz Kzt Kd Ke V 2 qh = 31.26 (eq. 26.10-1) GPp = -2 uplift γE = 1.5 (sec 29.4.4) γa = 0.76 (fig 29.4-8) γE = 1.5 FIG 29.4-7)γc = 0.98 (fig 29.4-7) hpt = 0 γa = 0.76 (fig 29.4-8)γp = 0.9 (fig 29.4-7)ω = 0.00 deg (panel tilt) GPp = -2 uplift GCrm = 1.4 uplift p = qh (GPp) γE γa (eq 29.4-7)p = qh (GCrn) γE γC γp (eq 29.4-6) p = -71.1 p.s.f.p = 58.0 p.s.f. Check Anchorage to Existing Structure 0.6DL - 0.6W controlling load combination (eq. 16-15 for ASD) DL = 2.9 p.s.f.dead load of panel (inlcuding rack system) W = 71.1 p.s.f.wind load normal to face of panel Arealag = 12.7 sq. ft.area tributary to each anchor SPanc = 4.0 ft.spacing of anchors Puplift = Arealag (0.6DL - 0.6W) = 521.3 lbs total uplift on anchor Material = DFL lumber anchor material Dialag = 5/16 in. diameter of screw Penlag = 2.5 in. min. penetration to existing framing Wlag = 266 lb/in. withdrawal load per in. of penetration per NDS Table 11.2A CD = 1.6 load duration factor for wind per NDS Table 2.3.2 Ct = 0.8 temperature factor per NDS Table 2.3.3 Noscrews = 1 number of screws in withdrawal Pallow = Penlag (Wlag CD Ct) * Noscrews = 851.2 lbs total allowable withrawal on anchor Puplift Pallow Anchorage = USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Wind Uplift Anchorage Flush Mounted Panels - ASCE Section 29.4.4 (where applicable) Flat Roof Panels - ASCE Section 29.4.3 (where applicable) = 0.61 < 1.00 Anchor is OK! 5/1/2023 2:01 PM 6 of 7 ©McPherson Engineering 724 S Deming St - 2017951406/16/23 McPherson Engineering By: T.B. Date: 5/1/23 Gravity Loads: DEMAND DECREASED BY 20.04% = OK! Lateral Loads: DEMAND INCREASED BY 8.34% < 10% = OK! Anchorage: DEMAND OF 521.3LB. < CAPACITY OF 851.2LB. = OK! USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Summary: STRUCTURE IS ADEQUATE FOR THE PROPOSED PV ARRAY ANCHORS ON EAVES/OVERHANGS ARE OK! Summary 5/1/2023 2:01 PM 7 of 7 ©McPherson Engineering 724 S Deming St - 2017951406/16/23 Rev: 8/29/19 SOL-01 CBC 2016 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M -19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST BETTER EARTH ELECTRIC INC 1024460 VICTORIA RUIZ 323-398-9324 VICTORIA.R@BETTEREARTH.SOLAR 724 DEMING ST 5/6/2023 724 S Deming St - 2017951406/16/23