Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
901 N Westwood - Plan
Template_version_v5_2025.04.08 PAGE REV: A 4/13/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SCOPE OF WORK GENERAL NOTES VICINITY MAPABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N)NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX REV NAME DATE COMMENTS INSTALLATION INSTRUCTIONS. CEC 2022. CEC 2022. INVERTER. SYSTEM COMPLIES WITH 690.41(A). ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS COVER SHEET PV-1.0 #ESTAMPCS #SSTAMPCS BACKUP GATEWAY:- (1) TESLA 1841000-X1-Y ENERGY GATEWAY 3 COUPLED) 1707000-XX-Y : 13.5 kWh PER PW3 TOTAL ENERGY CAPACITY (IN kWh): 27kWH NOTE: CEC 2022: 705.12(B)(3)(3): THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. PAGE #DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL PV-4.2 ELECTRICAL CALCS PV-4.3 BACKUP LOAD CALCS PV-4.4 PANEL SCHEDULE PV-5.0 SIGNAGE PV-5.1 SIGNAGE 2 Elect # 20185855 APPROVALS: ELECT - M. Smith ***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown.*** Template_version_v5_2025.04.08 PAGE REV: A 4/13/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PL PL PL PL PL PL PLPLPLPL PL PL ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE FIRE TESTING. SITE PLAN PV-2.0 #SSTAMPSP #ESTAMPSP POWERWALL ENERGY STORAGE SYSTEM (ESS) BG BACKUP GATEWAY GP GENERATION PANEL ELECTRIC VEHICLE SUPPLY EQUPMENTEV MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) SUNRUN METER DEDICATED PV METER SERVICE ENTRANCE INTERIOR EQUIPMENT SHOWN AS DASHED SE MP SM PM INV AC DC SUB-PANELSP CB IQ COMBINER BOX METER ADAPTERMA GROUNDING ELECTRODE ENERGY STORAGE SYSTEM BP BACKUP LOADS PANEL BI BACKUP INTERFACE 1 COMMUNICATION WIRESAM MD MICROGRID INTERCONNECT DEVICE ACREL METER SOLAREDGE METERSEMPV LOAD CENTERLC LEGEND SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND WILL APPEAR IN SITE PLAN RSD EXTERNAL RAPID SHUTDOWN SWITCH (E) CHIMNEY SITE PLAN - SCALE = 0'-0 3/64" = 1'-0" AC MD MP SE (E) RESIDENCE (E) GATE (TYP) (E) FENCE (E) PV EQUIPMENT (E) PV ARRAY (TYP) RSD INV AC (E) DETACHED STRUCTURE (TYP) (E) PATIO (TYP) AC AC LC CB (E) PV EQUIPMENT WE S T W O O D A V E BP Template_version_v5_2025.04.08 PAGE REV: A 4/13/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46J-BOX 18 Jinko Solar: JKM320M-60HBL EE Existing SolarEdge Technologies: SE7600H-USE Existing Inverter(s) J-BOX 13 JA Solar: JAM54S31-390/MR (13) Enphase Energy: IQ7PLUS-72-x-US EE Exising Enphase Combiner Panel E (E) AC DISCONNECT E (N) TESLA REMOTE METER (1) SOLAR PV CURRENT TRANSFORMER M NEW 200A BACKUP GATEWAY-3 1841000-X1-Y 2 C FACILITY GROUND EXISTING 200A MAIN BREAKER END FED EXISTING 200A MAIN PANEL 225A BUS 120/240VAC, SINGLE PHASE SERVICE 2 NEW 225A BACKUP LOADS PANEL WITH 200A MIAN BREAKER (2) (N) 60A ESS BREAKER (E) 60A PV BREAKER C (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 1 TESLA POWERWALL 3 1707000-XX-Y TESLA: POWERWALL 3 1707000-XX-Y (AC COUPLED) 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT 1 B (N) IMO PE69-3020, DISCONNECT SWITCH, 3P, 16A RSD TESLA POWERWALL 3 1707000-XX-Y TESLA: POWERWALL (AC COUPLED) 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT 1 RSD (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 1 B 200A (E) AC DISCONNECT EE (E) LOAD CENTER (E) 20A PV BREAKER (E) 40A PV BREAKER GATEWAY BREAKER AT OPPOSITE END OF BUSBAR 222013-005604 3 RELOCATED (E) LOADS A A (E) 125A LOAD CENTER PV-4.0 ELECTRICAL #ESTAMP Template_version_v5_2025.04.08 PAGE REV: A 4/13/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT E EXISTING 1 Battery Output (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT 2 Gateway / Backup load panel Feeder (2) 3/0 AWG THHN/THWN-2 (1) 3/0 AWG THHN/THWN-2 4 AWG THHN/THWN-2 2 EMT 3 Backup Loads (3) 12 AWG THHN/THWN-2 (3) 12 AWG THHN/THWN-2 8 AWG THHN/THWN-2 1-1/4 EMT(8) 10 AWG THHN/THWN-2 (6) 10 AWG THHN/THWN-2 8 AWG THHN/THWN-2 (2) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 8 AWG THHN/THWN-2 #ESTAMP CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR COLD WATER GAS BOND IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION APPLIES PER 2019 CEC 210.12 ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, AND EQUIPPED WITH A 2-POLE OCPD BREAKER PER CEC 210.4(B,D). PV-4.1 ELECTRICAL Template_version_v5_2025.04.08 PAGE REV: A 4/13/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 ALLOWABLE BACKFEED ALLOWABLE BACKFEED = MAIN BUS RATING = 225A LOADS IN MAIN PANEL: 00A LOADS + 200A GATEWAY BREAKER = 200A ≤ 225A INTERCONNECTION MEETS CEC 2022: 705.12(B)(3)(3) REQUIREMENTS. WIRE AMPACITY CALCULATED FROM 310.15(B)(16) & (17) AS APPROPRIATE WITH AMBIENT TEMPERATURE CALCULATIONS FROM 310.15(B)(3)(C) AND RACEWAY FILL ADJUSTMENTS FROM 310.15(B)(3)(A). CONDUIT ON THE ROOF SHALL BE INSTALLED NO LESS THAN 1" ABOVE THE ROOF DECK. PV CIRCUIT CONDUCTOR AMPACITY IS CONSTRAINED USING THE 75°C COLUMN WITH THE CONTINUOUS DUTY UPRATING OR THE 90°C COLUMN WITH THE RELEVANT AMBIENT TEMPERATURE AND RACEWAY FILL ADJUSTMENTS WITHOUT THE CONTINUOUS DUTY UPRATING PER 690.8(B), WHICHEVER RESULTS WITH A LARGER WIRE SIZE. NON-PV CIRCUIT CONDUCTORS USE THE AMPACITY IN THE 75°C COLUMN OR THE 90°C COLUMN WITH THE RELEVANT AMBIENT TEMPERATURE AND RACEWAY FILL ADJUSTMENTS, WHICHEVER IS LESS (110.14(C) & 310.15(A)(2)). THE RATING OF THE CONDUCTOR AFTER ADJUSTMENTS SHALL BE GREATER THAN, OR EQUAL TO, THE CONTINUOUS DUTY UPRATED CURRENT. CALC EX: WIRE AMPACITY X AMBIENT TEMP. CORR. FACTOR X CONDUIT FILL ADJ. FACTOR >= OUTPUT CURRENT PV-4.2 ELECTRICAL CALCS Template_version_v5_2025.04.08 PAGE REV: A 4/13/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 BACKUP LOADS LOAD BREAKER RATING (AMPS)LABEL DEMAND LOAD 1 15A-1P LIGHTING AND RECEPLTACLE 1500 W 2 15A-1P LIGHTING AND RECEPLTACLE 1500 W 3 15A-1P LIGHTING AND RECEPLTACLE 1500 W 4 20A-1P LIGHTING AND RECEPLTACLE 1500 W 5 20A-1P LIGHTING AND RECEPLTACLE 1500 W 6 20A-1P LIGHTING AND RECEPLTACLE 1500 W 7 20A-1P LIGHTING AND RECEPLTACLE 1500 W 8 25A-2P OTHER 4800 W 9 20A-2P TRM 3840 W 10 40A-2P OTHER 7680 W #ESTAMP PV-4.3 BACKUP LOAD CALCS BACKUP LOAD CALCS ALL BACKED UP LOADS ABOVE IN THE BACKED UP LOADS PANEL ARE RELOCATED FROM THE MAIN SERVICE PANEL. BACKED UP LOADS CALCULATION: (7680 VA)/ 240V = 32 A PER CEC 2022 ARTICLE 690.10 OR NEC 2020 ARTICLE 710.15. THE MAXIMUM CURRENT FOR ALL LARGE APPLIANCES LOADS IS 32A. (MAX LOADS OUTPUT) X (CONTINUOUS LOADS) = 32 A X 1.25 = 40A; BACKED UP LOADS PANEL BREAKER = 200A 40 A < 200A THEREFORE, THE AMPERAGE OF THE BACKED UP LOADS IS LESS THAN THAT OF THE OCPD. AC WIRE SIZING FOR BACKED UP LOADS PANEL: MAX AC OUTPUT CURRENT = (MAX LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = 32 A X 1.25 = 40A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] = 0.91 X 0.5 X 55A = 25.025A TERMINAL RATING[110.14(C)] = 8 AWG, 75°C RATED = 50A 25.025A < 50A → TERMINAL RATING GOVERNS CONDUCTOR SIZING. 50A ≤ 50A → 8 AWG AMPACITY OK THEREFORE 8 AWG IS SUFFICIENT. Template_version_v5_2025.04.08 PAGE REV: A 4/13/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 40 20 20 15 20 0 LIGHTING AND RECEPTACLE OTHER 225A BACKUP LOADS PANEL WITH 200A MAIN BREAKER ESS BREAKER FUTURE 225A/200A MAIN PANEL (E) PV ESS BREAKER 15 25 20 20 15 LIGHTING AND RECEPTACLE LIGHTING AND RECEPTACLE LIGHTING AND RECEPTACLE LIGHTING AND RECEPTACLE LIGHTING AND RECEPTACLE LIGHTING AND RECEPTACLE OTHER 60 60 60 20 0 (N) GATEWAY FEEDER BREAKER 20TRM PANEL SCHEDULE PV-4.4 #ESTAMP MAIN BREAKER (N) 200A GATEWAY 200 MAIN BREAKER Template_version_v5_2025.04.08 PAGE REV: A 4/13/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 NOMINAL ESS VOLTAGE VAC LABEL LOCATION: ENERGY STORAGE SYSTEM PER CODE(S): 2020 NEC 706.15(C), 2022 CEC 706.15(C) 120/240 520 VDCMAXIMUM ESS DC VOLTAGE:60 ENERGY STORAGE SYSTEM DISCONNECT SIGNAGE PV-5.0 #ESTAMP WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2), CEC 2022: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2022 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), CEC 2022: 690.13(B) ! WARNING! SOURCES: UTILITY GRID, BATTERY AND PV SOLAR ELECTRIC SYSTEM THREE POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), CEC 2022: 705.12(C) THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING! LABEL LOCATION: PV LOAD CENTER (IF APPLICABLE) AND ANY PANEL THAT UTILIZES "THE SUM OF BREAKERS RULE". PER CODE(S): NEC 2020: 705.12 (B)(3)(3), CEC 2022: 705.12 (B)(3)(3) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 48 AMPS 240 VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT Template_version_v5_2025.04.08 PAGE REV: A 4/13/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE 2 PV-5.1 #ESTAMP CAUTION: 901 WESTWOOD AVE SANTA ANA CA 92703 PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 MULTIPLE SOURCES OF POWER PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 MAIN SERVICE ENTRANCE SYSTEM SHUTDOWN DISCONNECT( 1 OF 3) PV SYSTEM(S) ARE EQUIPPED WITH RAPID SHUTDOWN DEVICE(S) SYSTEM SHUTDOWN DISCONNECT( 2 OF 3) SYSTEM SHUTDOWN DISCONNECT( 3 OF 3) Product datasheet Characteristics HOM1224L125PRB Main Product or component type Load Center Range of product Homeline Load center type Main lugs Line Rated Current 125 A Number of spaces 12 Number of circuits 24 NEMA degree of protection NEMA 3R outdoor Cover type Surface cover Electrical connection Lugs Complementary Short-circuit current 10 kA Number of tandem circuit breakers 12 Phase 1 phase System Voltage 120/240 V AC WG gauge WG 6...AWG 2/0 (aluminium) WG 6...AWG 1 (copper) Wiring configuration 3-wire Cover finish Gray baked enamel Material Tin plated aluminium busbar Enclosure material Welded galvannealed steel Surface finish Baked enamel grey Box number 3R Height 29.84 in (758 mm) Width 14.76 in (375 mm) Depth 4.53 in (115 mm) Environment product certifications UL E-6294 Offer Sustainability Green Premium product Green Premium product Compliant - since 1414 - Schneider Electric declaration of conformity Compliant - since 1414 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold vailable vailable Need no specific recycling operations Need no specific recycling operations WARNING: This product can expose you to chemicals including: WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause cancer and birth defects or other reproductive harm. Lead and lead compounds which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov For more information go to www.p65warnings.ca.gov Th e i n f o r m a t i o n p r o v i d e d i n t h i s d o c u m e n t a t i o n c o n t a i n s g e n e r a l d e s c r i p t i o n s a n d / o r t e c h n i c a l c h a r a c t e r i s t i c s o f t h e p e r f o r m a n c e o f t h e p r o d u c t s c o n t a i n e d h e r e i n . Th i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s . It i s t h e d u t y o f a n y s u c h u s e r o r i n t e g r a t o r t o p e r f o r m t h e a p p r o p r i a t e a n d c o m p l e t e r i s k a n a l y s i s , e v a l u a t i o n a n d t e s t i n g o f th e p r o d u c t s w i t h r e s p e c t t o t h e r e l e v a n t s p e c i f i c a p p l i c a t i o n o r u s e t h e r e o f . Ne i t h e r S c h n e i d e r E l e c t r i c I n d u s t r i e s S A S n o r a n y o f i t s a f f i l i a t e s o r s u b s i d i a r i e s s h a l l b e r e s p o n s i b l e o r l i a b l e f o r m i s u s e o f t h e i n f o r m a t i o n c o n t a i n e d h e r e i n . 1 / 1 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 1 of 8 GFT-OP-11a (22-August-2019) Test Verification of Conformity Verification Number: 104514208CRT-001VOC Applicant Name & Address: Tesla Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 Product Description: Energy Storage System Grid Support Utility Interactive & Standalone Inverter Ratings & Principle Characteristics: See Appendix 2 Models/Type References: 1707000- followed by two numbers; followed by -; followed by one letter. Brand Names: Tesla Relevant Standard(s) / Specification(s): See Appendix 1 Verification Issuing Office Name & Address: Intertek Testing Services NA, Inc. 3933 US Route 11, Cortland, NY 13045 USA Date of Tests: 9/15/2022 to 4/23/2024 Test Report Number(s): 104514208CRT-001, 104514208CRT-001RRF, 104514208CRT-001TRS, 104514208CRT-010, 104514208CRT-012 Additional information in Appendix. Signature Name: Mukund Rana Position: Sr. Staff Engineer Date: 10th May 2024 On the basis of the tests undertaken, the samples of the below product have been found to comply with the requirements of the referenced standards at the time the tests were carried out. This verification is part of the full test report and should be read in conjunction with it. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 2 of 8 GFT-OP-11a (22-August-2019) Appendix 1: Relevant Standard(s)/Specification(s) Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3] Grid Support Utility Interactive Equipment - Supplement SA to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SA)] Grid Support Utility Interactive Inverters and Converters Based Upon IEEE 1547:2018 & IEEE 1547.1:2020 - Supplement SB to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SB)] Energy Storage Systems and Equipment [ANSI/UL 9540:2020 Ed.2+R:09Apr2021] Photovoltaic (PV) DC Arc-Fault Circuit Protection [UL 1699B:2018 Ed.1+R:18May2021] Software in Programmable Components [UL 1998:2013 Ed.3+R:24Sep2018] Tests For Safety-related Controls Employing Solid-state Devices [UL 991:2004 Ed.3+R:09Jun2010] Batteries for Use in Stationary, Vehicle Auxiliary Power and Light Electric Rail (LER) Applications [ANSI/UL 1973:2018 Ed.2] IEEE 1547:2018 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces IEEE 1547a:2020 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces Amendment 1: To Provide More Flexibility for Adoption of Abnormal Operating Performance Category III IEEE 1547.1:2020 - IEEE Standard Conformance Test Procedures for Equipment Interconnecting Distributed Energy Resources with Electric Power Systems and Associated Interfaces Source requirements document UL 1741 (SRD) v2.0 – HECO Electric Rule No.21-2020 Generating Facility Interconnections Default New England Bulk System Area Settings Requirement PRC-024-3 Frequency and Voltage Protection Settings for Generating Resources GOVERNMENT OF PUERTO RICO PUBLIC SERVICE REGULATORY BOARD PUERTO RICO ENERGY BUREAU, Generating Facility and Microgrid Interconnection Regulation (“Regulation”), July 2021 Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] Safety Functions Incorporating Electronic Technology [CSA C22.2#0.8:2019 Ed.4] This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 3 of 8 GFT-OP-11a (22-August-2019) Appendix 2: Ratings & Principle Characteristics: ➢ Ratings: Models 1707000-xx-y Rated AC Output Power (W) 11500, 10000, 7680, 5750 Rated AC Input Power (W) Charging 5000 Max. Cont. Output Power (W) 11500, 10000, 7680, 5750 Max. Continuous Output PV to AC Power Off-Grid (W) 15400 Max. Cont. Input Power (W) Charging 5000 AC Input / Output Voltage (VL-L) 240 AC Output Frequency (Hz) 60 Max. Cont. Output Current (A) 48, 4 1.6, 32, 24 Max. Cont. Input Current (A) Charging 20.83 Apparent Power rating (VA) 11500, 10000, 7680, 5750 Apparent Power rating (VA) Charging 5000 Normal Category A, B Abnormal Category II, III ➢ Communication Protocol: IEEE 2030.5 protocol ➢ PCH board MD5 Firmware checksum: c5773b136a9ef9be9057302a67258482 ➢ TACO board MD5 Firmware checksum: dcq8OiBXbQWYnK9UhCAjvl02/py2MZymmwAQYOn8jSc= ➢ Grid Support Function Parameters: Tesla used the parameters in the Result reporting form “104514208CRT-001RRF” during the testing of the grid support functions according to UL1741 SB. The parameters that have “blank” as their value are not applicable. ➢ UL 1998 and CSA C22.2#0.8 Evaluation: ECU / Board Rev Software version Checksum UL1998, CSA C22.2#0.8 Compliant* Date of evaluation HVP / -E V2 51705DB5 Yes Apr-19-2024 PWS / -3F V2 34204954 Yes Apr-19-2024 PWS / -1F V2 B3C1375B Yes Apr-19-2024 PWS / -D V2 43FEF523 Yes Apr-19-2024 *Note: Below safety functions were evaluated during the UL1998 and UL 991 evaluation. • List of all UL1998 and UL 991 functions are as follow: o Overcharge o Over-discharge o Over Temperature o Over current o Relay weld, Isolation Monitoring Interruption, PV RSD (UL 1741) o AFCI (UL 1699B) This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 4 of 8 GFT-OP-11a (22-August-2019) This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 5 of 8 GFT-OP-11a (22-August-2019) Appendix 3: List of Tested Grid protection / Support Function: Table 3A: Test List -1 Grid protection / Support Function Tested Test Standards Sections and Source Requirement Documents IEEE 1547- 2018 IEEE 1547.1- 2020 UL 1741SB - 2021 CA Rule 21:2020 UL 1741 SRD V2.0 (HECO):2020 OPERATIONAL TEMPERATURE -- 5.3.3.1 SB4.3.5.3 -- Same as 1547- 2018 PROTECTION FROM ELECTROMAGNETIC INTERFERENCE (EMI) TEST 4.11.1 5.8.1 SB4.3.5.8.1 -- Same as 1547- 2018 SURGE WITHSTAND PERFORMANCE TEST 4.11.2 5.8.2 SB4.3.5.8.2 -- Same as 1547- 2018 PARALLELING DEVICE 4.11.3 5.8.3 -- -- Same as 1547- 2018 OVERVOLTAGE TRIP 6.4.1 5.4.2 SB4.3.5.4.2 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 UNDERVOLTAGE TRIP 6.4.1 5.4.3 SB4.3.5.4.3 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 OVERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 SB4.3.5.5.1 & SB4.3.5.5.2 Electric Rule No. 21 Table Hh.2 Same as 1547- 2018 UNDERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 SB4.3.5.5.1 & SB4.3.5.5.2 Electric Rule No. 21 Table Hh.2 Same as 1547- 2018 LOW VOLTAGE RIDE-THROUGH 6.4.2.3 & 6.4.2.5 5.4.4 SB4.3.5.4.4 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 HIGH VOLTAGE RIDE-THROUGH 6.4.2.4 5.4.7 SB4.3.5.4.7 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 LOW FREQUENCY RIDE-THROUGH 6.5.2.3 5.5.3 SB4.3.5.5.3 Electric Rule No. 21 Table Hh.2 SRD-UL-1741-SA- V2.0 (HECO) Part II B HIGH FREQUENCY RIDE- THROUGH 6.5.2.4 5.5.4 SB4.3.5.5.4 Electric Rule No. 21 Table Hh.2 SRD-UL-1741-SA- V2.0 (HECO) Part II B RATE OF CHANGE OF FREQUENCY 6.5.2.5 5.5.5 -- -- Same as 1547- 2018 ANTI-ISLANDING PROTECTION - WITH GRID SUPPORT FUNCTIONS ENABLED 8.1 5.10.2 SB4.3.5.10.2 Electric Rule No. 21 Hh.1a According to UL 1741 SA-V2.0 (HECO) TEST FOR VOLTAGE PHASE-ANGLE CHANGE RIDE-THOUGH (VARIATION 1) 6.5.2.6 5.5.6.1 SB4.3.5.5.6 -- Same as 1547- 2018 ENTER SERVICE 4.10 5.6 -- -- Same as 1547- 2018 SYNCHRONIZATION CONTROL FUNCTION TEST FOR EQUIPMENT WITH NO SYNCHRONIZING DISABLE CAPABILITY (VARIATION 3) 6.3 5.7.4 -- -- Same as 1547- 2018 LIMITATION OF DC INJECTION FOR INVERTERS 7.1 5.9 -- Electric Rule No. 21 Hh.2h Same as 1547- 2018 OPEN PHASE 6.2.2 5.11 -- -- Same as 1547- 2018 CURRENT DISTORTION 7.3 5.12 -- Electric Rule No. Same as 1547- This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 6 of 8 GFT-OP-11a (22-August-2019) Grid protection / Support Function Tested Test Standards Sections and Source Requirement Documents IEEE 1547- 2018 IEEE 1547.1- 2020 UL 1741SB - 2021 CA Rule 21:2020 UL 1741 SRD V2.0 (HECO):2020 21 Hh.2g 2018 LIMIT ACTIVE POWER 4.6.2 5.13 -- Electric Rule No. 21 Hh.8 Same as 1547- 2018 CONSTANT POWER FACTOR 5.3.2 5.14.3 SB4.3.5.14.3 Electric Rule No. 21 Hh.2i Same as 1547- 2018 VOLTAGE-REACTIVE POWER (VOLT-VAR) MODE FIXED VREF 5.3.3 5.14.4 SB4.3.5.14.4 Electric Rule No. 21 Hh.2J Same as 1547- 2018 VOLTAGE-REACTIVE POWER (VOLT-VAR) MODE (VREF TEST) 5.3.3 5.14.5 SB4.3.5.14.5 -- Same as 1547- 2018 ACTIVE POWER-REACTIVE POWER MODE (WATT-VAR) 5.3.4 5.14.7 SB4.3.5.14.7 -- Same as 1547- 2018 CONSTANT REACTIVE POWER (VAR) MODE 5.3.5 5.14.8 SB4.3.5.14.8 -- Same as 1547- 2018 VOLTAGE-ACTIVE POWER (VOLT- WATT) MODE 5.4 5.14.9 SB4.3.5.14.9 Electric Rule No. 21 Hh.2.m Same as 1547- 2018 TEST FOR FREQUENCY -DROOP (FREQUENCY-POWER OR FREQUENCY-WATT) CAPABILITY — ABOVE NOMINAL FREQUENCY 6.5.2.7 5.15.2 SB4.3.5.15.2 Electric Rule No. 21 Hh.2.l SRD-UL-1741-SA- V2.0 (HECO) Part II C TEST FOR FREQUENCY -DROOP (FREQUENCY-POWER OR FREQUENCY-WATT) CAPABILITY — BELOW NOMINAL FREQUENCY 6.5.2.7 5.15.3 SB4.3.5.15.3 Electric Rule No. 21 Hh.2.l SRD-UL-1741-SA- V2.0 (HECO) Part II C PRIORITIZATION OF DER RESPONSES 4.7 5.16 SB4.3.5.16 -- Same as 1547- 2018 LOAD REJECTION OVERVOLTAGE (LROV) 7.4 5.17.2 SB4.3.5.17.2 -- Same as 1547- 2018 FAULT CURRENT TESTS FOR INVERTERS 6.2.1 5.18.1 -- -- Same as 1547- 2018 PERSISTENCE OF DER PARAMETER SETTINGS -- 5.19 -- -- Same as 1547- 2018 NORMAL RAMP RATE -- -- -- Electric Rule No. 21 Hh.2k -- NAMEPLATE DATA TEST 10.3 6.4 -- -- Same as 1547- 2018 MONITORING INFORMATION TEST 10.5 6.6 SB4.3.6.6 -- Same as 1547- 2018 MANAGEMENT INFORMATION TEST 10.6 6.7 SB4.3.6.7 -- Same as 1547- 2018 CITY OF SANTA ANA Planning and Building Agency POWERWALL Backup Gateway The Backup Gateway for Tesla Powerwall provides energy management and monitoring for solar self -consumption, time -based control, and backup. The Backup Gateway controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a circuit breaker, the Backup Gateway can be installed at the service entrance. The Backup Gateway communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal) 230 V, 120/240 V Feed -In Type Single & Split Phase Grid Frequency 50 and 60 Hz Disconnect Current 200 A Maximum Input Short Circuit Current 10 kA Overcurrent Protection Device' 100-200 A: Service Entrance Rated Overvoltage Category Category IV AC Meter Revenue grade (+/- 1 %) Connectivity Ethernet, Cellular (3G)2, Wi-Fi User Interface Tesla App Operating Modes Support for solar self -consumption, time -based control, and backup Backup Operation Automatic disconnect for seamless backup transition Modularity Supports up to 10 AC -coupled Powerwalls Warranty 10 years Circrnt oreaker ecuired for nstallatio^ at 3eivice entrance. 'CellLlaf --onnecuvity Sublet t to se-v C2 ccve'a3E find ai0l:al sueriq]' , COMPLIANCE INFORMATION Certifications UL 1642, UL 1741, IEC 62109-1, CSA C22.2.107.1 Grid Connection Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003, IEC 61000-6-3. EN 55024, EN 301489-1, EN 301489-7, EN 301489-17 Environmental RoHS Directive 2011/65/EU, WEEE Directive 2012/19/EU, Battery Directive 2006/66/EC REACH Regulation Seismic AC156, IEEE 693-2005 (high) MECHANICAL SPECIFICATIONS Dimensions 740 mm x 378 min x 129 mm (29.1 inx149inx51 in) Weight 16.4 kg (36 Ibs) Mounting options Wall mount 378 mm 129 mm (14.9 in) (5.1 in) 740 mm (29.1 in) ENVIRONMENTAL SPECIFICATIONS Operating Temperature Operating Humidity (RH) Maximurn Elevation Environment Enclosure Type Ingress Rating -20'C to 50'C (-4`F to 122°F) Up to 100%, condensing 3000 m (9843 ft) Indoor and outdoor rated NEMA 3R IP44 .4 Approved FOR PERMIT ISSUANCE Master ID: Date: TSSLn Powerwall 3 Power Everything 2024 — Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to customize system behavior to meet their energy goals. Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has the ability to start heavy loads up to 185 A LRA, meaning a single unit can support the power needs of most homes. Powerwall 3 is designed for mass production,fast and efcient installations,easy system expansion,and simple connection to any electrical service. 22024Powerwall 3 Datasheet Solar Technical Specications Maximum Solar STC Input 20 kW Withstand Voltage 600 V DC PV DC Input Voltage Range 60 — 550 V DC PV DC MPPT Voltage Range 60 — 480 V DC MPPTs 6 Maximum Current per MPPT (Imp)13 A 5 Maximum Short Circuit Current per MPPT (Isc)15 A 5 Powerwall 3 Technical Specifications 1 Typical solar shifting use case. 2 Values provided for 25°C (77°F), at beginning of life. 3.3 kW charge/discharge power. 3 Tested using CEC weighted efciency methodology. 4 The customer is expected to provide internet connectivity for Powerwall 3;cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. 5 Where the DC input current exceeds the MPPT rating,a jumper can be used to combine two MPPTs into a single input to intake DC current up to 26 A IMP / 30 A ISC. Battery Technical Specications Nominal Battery Energy 13.5 kWh AC 2 Maximum Continuous Discharge Power 11.5 kW AC Maximum Continuous Charge Power 5 kW AC Output Power Factor Rating 0 -1 (Grid Code congurable) Maximum Continuous Current 48 A Maximum Output Fault Current 10 kA Load Start Capability (1 s)185 A LRA Power Scalability Up to 4 Powerwall 3 units supported System Technical Specications Model Number 1707000-xx-y Nominal Grid Voltage (Input &Output)120/240 VAC Grid Type Split phase Frequency 60 Hz Overcurrent Protection Device 60 A Solar to Battery to Home/Grid Efciency 89% 1,2 Solar to Home/Grid Efciency 97.5% 3 Supported Islanding Devices Gateway 3, Backup Switch, Backup Gateway 2 Connectivity Wi-Fi (2.4 and 5 GHz), Dual-port switched Ethernet, Cellular (LTE/4G 4) Hardware Interface Dry contact relay,Rapid Shutdown (RSD)certied switch and 2-pin connector, RS-485 for meters AC Metering Revenue Grade (+/- 0.5%) Protections Integrated arc fault circuit interrupter (AFCI), Isolation Monitor Interrupter (IMI),PV Rapid Shutdown (RSD)using Tesla Mid-Circuit Interrupters Customer Interface Tesla Mobile App Warranty 10 years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eb 3, 2020 : !!761;!: ;: ;: , 3 4 3 <)=2::5,3< 2#15()<== . )( *C . */3.%D // . )( * . )( // . --8 (/. 88 .#1 $+8 . E8 * - (.(.3+ .( -8.4 ,.4. / (/. .3 .A 8 ' -2- ./- .3 44428#14 ..32 23' $ 3( .$ ( . $/ /"C ' -8( . ( . E '*- (/ C % */ C E -8 ../- .C . 3( .. ( . ' . ( .< /. ( 3 (8 = .'.- . (( .'.- . (/( ( */( . /8 / *(.38 . . (4 . * . *:6-. 32024Powerwall 3 Datasheet Mechanical Specications Dimensions 1099 x 609 x 193 mm (43.25 x 24 x 7.6 in) Weight 130 kg (287 lb) Mounting Options Floor or wall mount Powerwall 3 Technical Specifications Environmental Specications Operating Temperature –20°C to 50°C (–4°F to 122°F) 6 Operating Humidity (RH)Up to 100%, condensing Storage Temperature –20°C to 30°C (–4°F to 86°F), up to 95% RH, non- condensing, State of Energy (SOE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating NEMA 3R Ingress Rating IP67 (Battery & Power Electronics) IP45 (Wiring Compartment) Pollution Rating PD3 Operating Noise @ 1 m < 50 db(A) typical <62 db(A)maximum Compliance Information Certications UL 1642, UL 1699B, UL 1741, UL 1741 SA, UL 1741 SB, UL 1741 PCS, UL 3741, UL 1973, UL 1998, UL 9540, IEEE 1547- 2018, IEEE 1547.1, UN 38.3 Grid Connection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) Fire Testing Meets the unit level performance criteria of UL 9540A 6 Performance may be de-rated at operating temperatures above 40°C (104°F). 609 mm 193 mm 1099 mm 42024Powerwall 3 Datasheet Electrical Specications Model MCI-1 MCI-2 Nominal Input DC Current Rating (IMP)13 A 13 A Maximum Input Short Circuit Current (ISC)19 A 17 A Maximum System Voltage (PVHCS)600 V DC 1000 V DC 7 Solar Shutdown Device Technical Specifications Environmental Specications Operating Temperature -40°C to 50°C (-40°F to 122°F) -45°C to 70°C (-49°F to 158°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) –30°C to 70°C (–22°F to 158°F) Enclosure Rating NEMA 4X /IP65 NEMA 4X /IP65 RSD Module Performance Maximum Number of Devices per String 5 5 Control Power Line Excitation Power Line Excitation Passive State Normally Open Normally Open Maximum Power Consumption 7 W 7 W Warranty 25 years 25 years — The Solar Shutdown Device is a Mid-Circuit Interrupter (MCI)and is part of the PV system rapid shutdown (RSD)function in accordance with Article 690 of the applicable NEC. When paired with Powerwall 3, solar array shutdown is initiated by any loss of AC power. Mechanical Specications Electrical Connections MC4 Connector MC4 Connector Housing Plastic Plastic Dimensions 125 x 150 x 22 mm (5 x 6 x 1 in) 173 x 45 x 22 mm (6.8 x 1.8 x 1 in) Weight 350 g (0.77 lb) 120 g (0.26 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw Wire Clip Compliance Information Certications UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) RSD Initiation Method External System Shutdown Switch or Powerwall 3 Enable Switch 7 Maximum System Voltage is limited by Powerwall to 600 V DC. UL 3741 PV Hazard Control (and PVRSA)Compatibility See Powerwall 3 Installation Manual 52024Powerwall 3 Datasheet Gateway 3 8 Only Eaton CSR or BWH main breakers are 25 kA rated. Performance Specications Model Number 1841000-01-y Nominal Grid Voltage 120/240 V AC Grid Conguration Split phase Grid Frequency 60 Hz Continuous Current Rating 200 A Maximum Supply Short Circuit Current 22 kA with Square D or Eaton main breaker 25 kA with Eaton main breaker 8 IEC Protective Class Class I Overvoltage Category Category IV Mechanical Specications Dimensions 660 x 411 x 149 mm (26 x 16 x 6 in) Weight 16.3 kg (36 lb) Mounting options Wall mount Environmental Specications Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Compliance Information Certications UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2 107.1, CSA 22.2 29 Emissions FCC Part 15, ICES 003 — Tesla Gateway 3 controls connection to the grid in a Powerwall system, automatically detecting outages and providing seamless transition to backup power. It provides energy monitoring that is used by Powerwall for solar self-consumption, time-based control, and backup operation. 411 mm 660 mm 149 mm AC Meter Revenue accurate (+/- 0.5%) Communication CAN User Interface Tesla App Backup Transition Automatic disconnect for seamless backup Overcurrent Protection Device 100–200 A Service entrance rated Eaton CSR, BWH, or BW, or Square D QOM breakers Internal Panelboard 200 A 8-space/16 circuit breakers Eaton BR, Siemens QP, or Square D HOM breakers rated to 10–125A Warranty 10 years 62024Powerwall 3 Datasheet Backup Switch 9 Breaker maximum supply short circuit current rating must be equal to or greater than the available fault current. Performance Specications Model Number 1624171-xx-y Continuous Load Rating 200 A, 120/240 V split phase Maximum Supply Short Circuit Current 22 kA with breaker 9 Communication CAN AC Meter Revenue accurate (+/- 0.5%) Expected Service Life 21 years Warranty 10 years Mechanical Specications Dimensions 176 x 205 x 74 mm (6.9 x 8.1 x 2.9 in) Weight 2.8 lb Meter and Socket Compatibility ANSI Type 2S, ringless or ring type External Service Interface Contactor manual override 10 Reset button Conduit Compatibility 1/2-inch NPT Environmental Specications Operating Temperature –40°C to 50°C (–40°F to 122°F) Storage Temperature –40°C to 85°C (–40°F to 185°F) Enclosure Rating NEMA 3R Pollution Rating PD3 Compliance Information Safety Standards USA: UL 414, UL 414 SB, UL 2735, UL 916, CA Prop 65 Emissions FCC, ICES 10 Manually overrides the contactor position during a service event. — The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility meter or in a standalone meter panel downstream of the utility meter. The Backup Switch automatically detects grid outages, providing a seamless transition to backup power. It communicates directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app. 204.86 74 176 mm 205 mm 74 mm 72024Powerwall 3 Datasheet Backup Gateway 2 Performance Specications Model Number 1232100-xx-y AC Voltage (Nominal)120/240 V Feed-in Type Split phase Grid Frequency 60 Hz Current Rating 200 A Maximum Supply Short Circuit Current 10 kA 11 Overcurrent Protection Device 100 - 200 A, Service entrance rated 9 Overvoltage Category Category IV Internal Primary AC Meter Revenue accurate (+/- 0.2%) Internal Auxiliary AC Meter Revenue accurate (+/- 2%) Primary Connectivity Ethernet, Wi-Fi Secondary Connectivity Cellular (3G, LTE/4G) 12 Mechanical Specications Dimensions 660 x 411 x 149 mm (26 x 16 x 6 in) Weight 20.4 kg (45 lb) Mounting options Wall mount, Semi-Bush mount Environmental Specications Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Compliance Information Certications UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2 0.19, CSA 22.2 205 Emissions FCC Part 15, ICES 003 411 mm 660 mm 149 mm 11 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. 12 Cellular connectivity subject to network operator service coverage and signal strength. — Backup Gateway 2 controls connection to the grid when paired with Powerwall 3, automatically detecting outages and providing seamless transition to backup power. Backup Gateway 2 also provides energy metering for solar self-consumption, time-based control, and backup operation. In this system conguration,Powerwall 3 acts as the Site Controller,with the Backup Gateway 2 Site Controller disabled. User Interface Tesla App Operating Modes Support for solar self- consumption, time-based control, and backup Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC- coupled Powerwalls Optional Internal Panelboard 200 A 6-space / 12 circuit breakers Siemens QP or Square D HOM breakers rated 10 - 80A or Eaton BR breakers rated 10 - 125A Warranty 10 years 82024Powerwall 3 Datasheet Powerwall 3 Example System Configurations Powerwall 3 with Backup Switch Whole Home Backup Powerwall 3 with Gateway 3 Whole Home Backup Powerwall 3 with Backup Gateway 2 Partial Home Backup This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 7 of 8 GFT-OP-11a (22-August-2019) Table 3B: Test List -2 Test Description CSA C22.2#107.1:2016 Ed. 4 CSA C22.3#9:2020 Ed 2 Screw Tightening Torque Test 3.6.3 -- Impedance Test 105.1/10.5.2 -- Continuity Test 4.1 -- Output Power Factor 4.2 -- Voltage Harmonics for stand alone 15.3.2.1 -- Frequency 10.5.4 -- Stand-alone inverter dc output short-circuits current contribution 10.5.5 -- Normal ramp rate -- 7.2.3.4.2 / 8.3.12.2.3 Flicker -- 7.2.2 / 8.3.13 Test for constant reactive power (var) mode 7.2.3.3.3 / 8.3.12.2.2 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 8 of 8 GFT-OP-11a (22-August-2019) Appendix 4: Revision Summary Date / Project Engineer Comments 15-Feb-2023 Dipesh Patel Original issue date 8-Mar-2023 / G104200718 Dipesh Patel Added UL 1699B, UL 1998 and UL 991 standards 24-Mar-2023/ G104200718 Dipesh Patel Added UL 1973 standard. Added normal and abnormal category in ratings table. 18-Apr-2023 / G104200718 Dipesh Patel Added additional factory settable nameplate ratings rated output active power (W): 9600, 7680, 5750; Max. Continuous output power (W): 9600, 7680, 5750; Max. Cont. Output Current (A): 40, 32, 24; Apparent Power rating (VA): 9600, 7680, 5750 Added Puerto Rico Interconnection regulation as it refers to UL 1741 and IEEE 1547-2018. 1-May-2024 / G104514208 Mukund Rana A) Added standards. Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] B) Update CSA C22.2#0.8 standard C) added Table 3B: Test List -2 City of Santa Ana, I, Jose Guerrero, grant authorization to SUNRUN SOLAR to install Rooftop Mounted Solar on my residence located at 901 westwood ave , SANTA ANA, CA, 92703. SIGNATURE:___________________ DATE:__________ 717 17th Street, Ste. 200 | Denver, CO 80202 Docusign Envelope ID: 08D0D05F-38AF-48B4-9BAB-C586BEC44387 4/19/2025 Certificate Of Completion Envelope Id: 08D0D05F-38AF-48B4-9BAB-C586BEC44387 Status: Completed Subject: SUNRUN URGENT NEEDED FOR PERMITS Complete with Docusign: Solar Authorization Letter.pdf EmployeeName: TermDate: Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 5 Initials: 0 Bobby Cautela AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 225 Bush Street, Suite 1400 San Francisco, CA 94104 robert.cautela@sunrun.com IP Address: 174.65.135.37 Record Tracking Status: Original 4/18/2025 5:13:49 PM Holder: Bobby Cautela robert.cautela@sunrun.com Location: DocuSign Signer Events Signature Timestamp Jose Guerrero eguerrero99@icloud.com Security Level: Email, Account Authentication (None) Signature Adoption: Drawn on Device Using IP Address: 108.228.227.70 Signed using mobile Sent: 4/18/2025 5:14:28 PM Viewed: 4/19/2025 9:38:09 AM Signed: 4/19/2025 9:39:55 AM Electronic Record and Signature Disclosure: Accepted: 4/19/2025 9:38:09 AM ID: 2a22cf1e-e300-441a-bd2c-5efbe36df65a In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 4/18/2025 5:14:28 PM Certified Delivered Security Checked 4/19/2025 9:38:09 AM Signing Complete Security Checked 4/19/2025 9:39:55 AM Completed Security Checked 4/19/2025 9:39:55 AM Payment Events Status Timestamps Electronic Record and Signature Disclosure DIVULGACIÓN DE FIRMA Y REGISTRO ELECTRÓNICOS De vez en cuando, es posible que de SunRun Inc. (nosotros o la empresa) esté obligado por ley a brindarle ciertas divulgaciones o notificaciones por escrito. A continuación se describen los términos y condiciones para brindar dichas divulgaciones y notificaciones electrónicamente a través de su cuenta de usuario de DocuSign, Inc. (DocuSign) Express. Lea la siguiente información detenida y exhaustivamente y, si puede acceder a esta información electrónicamente, está conforme con esta y acepta los términos y condiciones, confirme su aceptación haciendo clic en el botón “Aceptoâ€? en la parte inferior del documento. Cómo obtener copias impresas Puede solicitarnos en cualquier momento una copia impresa de los registros que nosotros brindamos o pusimos a disposición electrónicamente para usted. Para dichas copias, siempre que sea usuario autorizado del sistema DocuSign, tendrá la capacidad de descargar e imprimir los documentos que le enviamos a través de su cuenta de usuario de DocuSign por un perÃ-odo limitado (generalmente, 30 dÃ-as) después de que dichos documentos se le hayan enviado por primera vez. Después de dicho perÃ-odo, si desea que le enviemos copias impresas de los documentos mencionados desde nuestra oficina para usted, se le cobrará una tarifa de $0.00 por página. Puede solicitar que le entreguemos dichas copias impresas siguiendo el procedimiento descrito a continuación. Cómo retirar su consentimiento Si decide recibir notificaciones y divulgaciones de nuestra parte electrónicamente, puede cambiar de parecer en cualquier momento e informarnos que, a partir de entonces, desea recibir las notificaciones y las divulgaciones requeridas solo en formato impreso. Se describe a continuación cómo debe informarnos su decisión de recibir notificaciones y divulgaciones en formato impreso y retirar su consentimiento para recibir notificaciones y divulgaciones electrónicamente. Consecuencias de cambiar de parecer Si elige recibir las notificaciones y las divulgaciones requeridas solo en formato impreso, habrá una mayor demora para poder completar ciertos pasos en las transacciones y ejecutar los servicios para usted, ya que primero deberemos enviarle las notificaciones y las divulgaciones requeridas a usted en formato impreso y, luego, esperar hasta que obtengamos la confirmación de que ha recibido dichas notificaciones y divulgaciones impresas. Para indicarnos que cambia de parecer, debe retirar su consentimiento usando el formulario “Retirar consentimientoâ€? de DocuSign en la página de firmas de su cuenta de DocuSign. Esto nos indicará que ha retirado su consentimiento para recibir las notificaciones y las divulgaciones requeridas electrónicamente de parte nuestra y ya no podrá usar su cuenta de usuario de DocuSign Express para recibir las notificaciones y los consentimientos requeridos de forma electrónica de parte nuestra o firmar electrónicamente los documentos que le enviemos. Todas las notificaciones y las divulgaciones se le enviarán electrónicamente. A menos que le indiquemos lo contrario en conformidad con los procedimientos descritos en el presente documento, le brindaremos electrónicamente, a través de su cuenta de usuario de DocuSign, todas las notificaciones, las divulgaciones, las autorizaciones, las confirmaciones y otros documentos que se exigen que le brindemos o pongamos a su disposición durante el curso de nuestra relación con usted. Para reducir las posibilidades de que no reciba las notificaciones ni las divulgaciones de manera inadvertida, preferimos brindarle todas las notificaciones y las Electronic Record and Signature Disclosure created on: 7/23/2015 6:10:45 PM Parties agreed to: Jose Guerrero divulgaciones requeridas a usted usando el mismo método y la misma dirección que nos ha proporcionado. Por lo tanto, puede recibir todas las divulgaciones y las notificaciones electrónicamente o en formato impreso a través del sistema de entrega por correo postal. Si no está de acuerdo con este proceso, infórmenos como se describe más abajo. Consulte también el párrafo anterior que describe las consecuencias de su elección de no recibir el envÃ-o de notificaciones y divulgaciones electrónicamente de parte nuestra. Cómo comunicarse con el SunRun Inc.: Puede comunicarse con nosotros para informarnos los cambios respecto de cómo podemos ponernos en contacto electrónicamente, para solicitarnos copias impresas de cierta información y para retirar su consentimiento previo con el objeto de recibir notificaciones y divulgaciones electrónicamente de la siguiente manera: Para comunicarse con nosotros por correo electrónico, envÃ-e un mensaje a customercare@sunrun.com También puede comunicarse con nosotros por escrito a 45 Fremont Street, 32nd Floor, San Francisco, CA 94105 o por teléfono al 1-855-478-6786. Cómo informar al de SunRun Inc. su nueva dirección de correo electrónico Para avisarnos que ha cambiado la dirección de correo electrónico al que le enviamos notificaciones y divulgaciones electrónicamente, debe enviarnos un mensaje de correo electrónico a customercare@sunrun.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. y en el cuerpo de dicha solicitud debe indicar su dirección de correo electrónico anterior y la dirección de correo electrónico nueva. No necesitamos otra información de su parte para cambiar su dirección de correo electrónico. Además, debe notificar a DocuSign, Inc. a fin de solicitar que su nueva dirección de correo electrónico se refleje en su cuenta de DocuSign siguiendo el proceso para cambiar el correo electrónico en DocuSign. Para solicitar copias impresas al de SunRun Inc. Para solicitarnos la entrega de copias impresas de las notificaciones y las divulgaciones que le enviáramos anteriormente de forma electrónica, debe dirigirnos un mensaje de correo electrónico a customercare@sunrun.com, y en el cuerpo de dicha solicitud debe indicar su dirección de correo electrónico, nombre completo, dirección postal en los EE. UU. y número de teléfono. Le facturaremos las tarifas en ese momento si corresponde. Cómo retirar su consentimiento para de SunRun Inc. Para informarnos que ya no desea recibir notificaciones ni divulgaciones futuras en formato electrónico, puede elegir entre las siguientes alternativas: i. Negarse a firmar documentos dentro de su cuenta de DocuSign y, en la página subsiguiente, seleccionar la casilla de verificación que indica que desea retirar su consentimiento. ii. Enviarnos un mensaje de correo electrónico a customercare@sunrun.comy en el cuerpo de dicha solicitud debe indicar su dirección de correo electrónico, nombre completo, dirección postal en los EE. UU., número de teléfono y número de cuenta. No necesitamos otra información de su parte para retirar el consentimiento.. Las consecuencias de retirar el consentimiento para los documentos en lÃ-nea serán que las transacciones tardarán más para procesarse.. Requisitos de hardware y software Sistemas operativos: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X Exploradores: Versiones versión final de Internet Explorer® 6.0 o superior (Sólo en Windows); Mozilla Firefox 2.0 or o superior (Windows y Mac); Safariâ„¢ 3.0 o superior (Sólo en Mac) Lector de PDF: Acrobat® o software similar pueden ser requeridos para ver e imprimir archivos PDF Resolución de pantalla: 800 x 600 como mÃ-nimo Configuración de seguridad: Permitir cookies por sesión ** Estos requisitos mÃ-nimos están sujetos a cambios. Si cambian estos requisitos, le enviaremos un mensaje de correo electrónico a su dirección que tenemos en archivo en el que indicaremos los requisitos revisados de hardware y software y, en ese momento, tendrá el derecho de retirar su consentimiento. Avisos Cualquier notificación u otra comunicación que deba hacer a continuación , aun cuando sea requerido para ser por escrito en virtud de otras disposiciones del presente consentimiento o cualesquiera otros documentos o acuerdos que se han proporcionado a usted en relación con este consentimiento , alternativamente puede estar hecho en un registro electrónico transmitida electrónicamente a las direcciones electrónicas proporcionadas por usted. Cualquier notificación u otra comunicación realizada por medios electrónicos tendrán los mismos efectos jurÃ-dicos y aplicabilidad como si se hace en forma no electrónica. Cómo confirmar su acceso y consentimiento para recibir los materiales electrónicamente Para confirmarnos que puede acceder a esta información electrónicamente, que será similar a otras notificaciones y divulgaciones electrónicas que le enviemos, verifique que pudo leer esta divulgación electrónica y que también pudo imprimir o guardar electrónicamente esta página como futura referencia y acceso o que pudo enviar por correo electrónico esta divulgación y consentimiento a una dirección en la que los podrá imprimir o guardar para futura referencia y acceso. Además, si da su consentimiento para recibir notificaciones y divulgaciones exclusivamente en formato electrónico de acuerdo con los términos y condiciones descritos anteriormente, infórmenos haciendo clic en el botón “Aceptoâ€? más abajo. Al marcar la casilla “Aceptoâ€?, confirmo lo siguiente: • Puedo acceder y leer este documento electrónico de CONSENTIMIENTO PARA LA RECEPCIÓN ELECTRÓNICA DE DIVULGACIÓN DE FIRMA Y REGISTRO ELECTRÓNICOS. • Puedo imprimir la divulgación o guardarla en un lugar en el que puedo imprimir la divulgación para futura referencia y acceso o enviarla a dicho lugar. • Hasta o a menos que notifique al de SunRun Inc. como se describe anteriormente, doy mi consentimiento para recibir exclusivamente a través de medios electrónicos todas las notificaciones, las divulgaciones, las autorizaciones, las confirmaciones y otros documentos que el de SunRun Inc. debe brindarme o poner a mi disposición durante el curso de mi relación con ustedes. Provisión Acuerdo completo Este acuerdo y la declaración de divulgación del consumidor ejecutado por el cliente junto con y simultáneamente con su revisión y aceptación de los términos establecidos en este documento constituyen el acuerdo completo entre las partes con respecto al objeto del mismo y reemplaza cualquier entendimiento previo , acuerdos o representaciones por o entre las partes , escritas u orales , en la medida en que se relacionan de alguna manera con el objeto del mismo . Service Voltage 240 Section 220.82 Dwelling Unit Part #1 - Section 220.82(B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Amps Box A (VA) 20.5 4920 Part #2 - Section 220.82(B)(3)a, b, c, d - Appliances and Dedicated Circuits: Size in VA Size in VA 1500 1500 1500 1000 600 1000 1600 3840 7680 Amps Box B (VA) 84.25 20220 Total VA from Parts #1 and #2 combined:Box A + Box B =25140 Total VA 25140 First 10000 VA @ 100%10000 Remaining VA @ 40% Remaining VA =15140 15140 x 40% =6056 VA Adding First 10000 VA, if possible 10000 VA Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:16056 VA Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:66.90 Amps Part #3 - Section 220.82(C) Heating and A/C loads: *Combine the larger loads of either the Heating or the A/C loads togther 100% of all the Heating or A/C loads in VA:0 VA 100% of all the Heating or A/C loads in Amps:0.00 A VA Volts Amps Parts #1 & #2 16056 240 66.90 Part #3 0 240 0.00 Total VA for all Parts:16,056 Totals Service/Feeder Load 66.90 Dedicated circuit Dedicated circuit Article 220 - Dedicated Backup Panel Calculation Job Code 901 Westwood Ave Santa Ana CA US 92703 109R-901GUER2 Building Square Footage VA (watts)Amps House 1640.00 4920 20.50 Total for Part #1: Laundry Appliance Circuit - 1 Appliance Circuit - 2 Dishwasher Disposal Refrigerator Microwave Other Other Totals for Part #2: Totals from all Parts Section 220.82 Dwelling Unit Part #1 - Section 220.82 (B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Amps Box A (VA) 20.5 4920 Part #2 - Section 220.82 Size in VA Size in VA 1500 N/A 3000 N/A 1000 N/A 600 N/A 1000 N/A 1600 N/A 3840 N/A 7680 N/A N/A N/A N/A Amps Box B (VA) N/A 84.25 20220 Total VA from Parts #1 and #2 combined:Box A + Box B =25140 Total VA 25140 First 10,000 VA @ 100%10000 Remaining VA @ 40% Remaining VA =15140 15140 x 40% =6056 VA Adding First 10,000 VA 10000 VA Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:16056 VA Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:66.90 Amps Part #3 - Section 220.82 (C) Heating and A/C loads: *Combine the larger loads of either the Heating or the A/C loads togther 100% of all the Heating or A/C loads in VA:0 VA 100% of all the Heating or A/C loads in Amps:0.00 A VA Volts Amps Parts #1 & #2 16056 240 66.90 Part #3 0 240 0.00 Total VA for all Parts:16,056 Totals Service/Feeder Load 66.90 #ESTAMP Laundry Appliance Circuit(s) Dishwasher(s) Disposal(s) Dedicated circuit House Square Footage 1640 Article 220 - Service/Feeder calculation for (address): 901 Westwood Ave Santa Ana CA US 92703 Building VA (watts) 4920 Amps 20.5 Job Code 109R-901GUER2 Totals from all Parts Dedicated circuit Total for Part #1: Refrigerator(s) Microwave(s) Totals for Part #2: Other Other Oven Pool Equipment Bus Rating:225 Main Rating:200 0%0% Not Fed by other panels Feeds: Panel 2 66.90 0.00 66.90 Bus Rating:225 Main Rating:200 100%100% Itemized House and 240V Loads for Panel: (VA) 1500 1500 1500 1000 600 1000 1600 3840 7680 Fed by: Panel 1 66.90 66.90 Other Load Calc: (This Panel) Total Load Calc: Appliance Circuit - 2 Dishwasher Disposal Refrigerator Microwave Other Panel 2 of 2 Panel % of Sq.Ft:Panel % of 100% VA: Laundry Appliance Circuit - 1 Panel 1 of 2 Panel % of Sq.Ft:Panel % of 100% VA: Load Calc: (This Panel) Total Load Calc: