Loading...
HomeMy WebLinkAbout909 N Grand Ave - Plan360kW DC Charging Split System Dynamic Power Allocation for Fast Charging 909 N Grand Ave - 101116238 & 201806132/15/2024 360kW Split System Visit our website | btcpower.com Power Engine Cabinet Model SKU HPCT2-180-480-2 HPCT2-240-480-2 HPCT2-360-480-2 Power Rating 180 kW 240 kW 360 kW Number of Power Engines 6 8 12 Input Voltage Range 480 VAC, 3 Phase, +10% / -15% 480 VAC, 3 Phase, +10% / -15% 480 VAC, 3 Phase, +10% / -15% Input Current @ 480 VAC 239 A 320 A 466 A Power Factor > 0.99 full load > 0.99 full load > 0.99 full load Efficiency > 94%> 94%> 94% Max. Out DC Current (Per Channel)500 A 500 A 500 A Max. Output DC Voltage 200 - 950 VDC 200 - 950 VDC 200 - 950 VDC Max # of Dispensers 2 2 2 Dimension & Weight 30"W x 34.5"D x 93" H, 1,655 Ibs 30”W x 34.5”D x 93” H, 1,655 Ibs 30"W x 34.5"D x 93" H, 1,655 Ibs Dispenser Model SKU HPCD1-350-01-003 HPCD1-350-02-003 Connectors CHAdeMO SAE CCS1 (Liquid Cooled) SAE CCS1 (Liquid Cooled) SAE CCS1 (Liquid Cooled) Rated Output Current 200 A 350 A (500 A Boost) 350 A (500 A Boost) 350 A (500 A Boost) Max DC Voltage (VDC)500 V 950 V 950 V 950 V Output Power 350kW Max Input Power (Auxiliary)120 VAC Input Current (Auxiliary)21 A (FLA) Breaker Size 30 A Network OPP 1.6. BTCP Network Dimension & Weight 22"W x 15" D x 97"H, 600 Ibs Environmental and Compliance (System) Ambient Condition -30 °C to +50 °C, 95% Humidity, 6000 ft Altitude. NEMA 3R Safety Compliance ETL Listed for USA and Canada: Complies with UL 2202, UL 2231, UL50E, NEC Article 625, CSA STD C22.2 No. 107.1 FCC Part 15 Class A Standard Dynamic Power Allocation in 90kW increments System available in 1 or 2-dispenser configuration Payment types: CC, RFID (OCPP Network Enabled) 15” Outdoor Color Display Connector Configuration: Dual CCS1 CHAdeMO and CCS1 Optional ISO 15118:2014 Customizable Backlit Acrylic Topper Apple & Android Pay (based on network provider) 909 N Grand Ave - 101116238 & 201806132/15/2024 909 N Grand Ave - 101116238 & 201806132/15/2024 909 N Grand Ave - 101116238 & 201806132/15/2024 Tom's Truck Center #2 Civil and Structural Design Calculations NV5 Project No. 0000690_F8 For Charge Ready Program November 3, 2023 IFC Design P:\2296-PMO\SCE Charge Ready (CR) Program\19-0000690_ChargeReady\F8_Tom_Truck_2\Structural\Calc Package\Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 1.0 EV-SWBD Foundation 1.1 Foundation Design 1.2 RISA Foundation Output 1.3 Anchorage Design 1.4 Equipment Drawing 2.0 100A-SW Foundation 2.1 Foundation Design 2.2 RISA Foundation Output 2.3 Anchorage Design 2.4 Equipment Drawing 3.0 400A-SW Foundation 3.1 Foundation Design 3.2 RISA Foundation Output 3.3 Anchorage Design 3.4 Equipment Drawing 4.0 Wind Design Parameters 5.0 Seismic Design Parameters Index Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 1.0 EV-SWBD Foundation Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 1.1 Foundation Design Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 Structural Calculations Charge Ready Program Date: 10/27/2023 Calculated by: MM Checked By: DPB Electrical Equipment Pad - Structural Calculation _________________________________________________________________________ I. References 1. ASCE 7-16 2. Z & Powe Distribution"EV SWBD-1" Dwg- 2309-3-16362A 3. Z & Powe Distribution"EV SWBD-2" Dw- 2309-3-16362B 4. GE 150kVA Transformer Dwg 303B111GEDYP76A II. Equipment Information EV SWBD-1 weq1 76in(Width of Equipment) leq1 42in(Length of Equipment) h eq1 90in(Height of Equipment) Weq1 2000lb(Weight of Equipment) h g1 0in(Height above Ground) EV SWBD-2 weq2 32in(Width of Equipment) leq2 30in(Length of Equipment) h eq2 64in(Height of Equipment) Weq2 402lb(Weight of Equipment) h g2 0in(Height above Ground) 150kVA Transformer weq3 37.3in(Width of Equipment) (Length of Equipment)leq3 24in (Height of Equipment)h eq3 35.6in (Weight of Equipment)Weq3 1050lb Page: 1 of 5 909 N Grand Ave - 101116238 & 201806132/15/2024 Structural Calculations Charge Ready Program Date: 10/27/2023 Calculated by: MM Checked By: DPB (Height above Ground; Assumed)h g3 6in III. Equipment Loading Dead Load: SF 1.1(Safety Factor to Account for Misc Parts) EV SWBD-1 DL1 Weq1 SF weq1 leq199.25 lb ft2(Uniform load) EV SWBD-2 DL2 Weq2 SF weq2 leq266.33 lb ft2(Uniform load) 150kVA Transformer DL3 Weq3 SF weq3 leq3185.79 lb ft2(Uniform load) Wind Load: V 95mph(Basic Wind Speed: Risk Category II) Exposure Category C k d 0.85(ASCE Table 26.6-1) k zt 1.0(ASCE 7-16 Section 26.8.1) k e 1.0(ASCE Table 26.9-1) k z 0.85(ASCE Table 26.10-1) Gf 0.85(ASCE Equation 26.10-1) Cf 1.4(ASCE Figure 29.4-1) q z 0.00256 kzk ztkdkeV2 lb ft2 mph2   16.69 lb ft2(Design Wind Pressure) Page: 2 of 5 909 N Grand Ave - 101116238 & 201806132/15/2024 Structural Calculations Charge Ready Program Date: 10/27/2023 Calculated by: MM Checked By: DPB EV SWBD-1 Wx1 Gf Cfq zweq1heq1943.55 lb(Force due to Wind in X-Direction) Mz1 Wx1 h g1 heq1 2 3.54 kip ft Wz1 Gf Cfq zleq1heq1521.44 lb(Force due to Wind in Z-Direction) Mx1 Wz1 h g1 heq1 2 1.96 kip ft EV SWBD-2 Wx2 Gf Cfq zweq2heq2282.51 lb(Force due to Wind in X-Direction) Mz2 Wx2 h g2 heq2 2 0.75 kip ft Wz2 Gf Cfq zleq2heq2264.86 lb(Force due to Wind in Z-Direction) Mx2 Wz2 h g2 heq2 2 0.71 kip ft 150kVA Transformer Wx3 Gf Cfq zweq3heq3183.18 lb(Force due to Wind in X-Direction) Mz3 Wx3 h g3 heq3 2 0.36 kip ft Wz3 Gf Cfq zleq3heq3117.86 lb(Force due to Wind in Z-Direction) Mx3 Wz3 h g3 heq3 2 0.23 kip ft Seismic Load: SDS 1.034(Spectral Acceleration, short period, ASCE 7-16 Section 11.4.5) SD1 0.461(Spectral Acceleration,1s period, ASCE 7-16 Section 11.4.6) Page: 3 of 5 909 N Grand Ave - 101116238 & 201806132/15/2024 Structural Calculations Charge Ready Program Date: 10/27/2023 Calculated by: MM Checked By: DPB Ie 1.5(Importance Factor, ASCE 7-16 Section 13.1.3) ap 1.0(Amplification Factor, ASCE 7-16 Table 13.6-1) Rp 2.5(Response Modification Factor, ASCE 7-16 Table 13.6-1) Ω 2(Overstrength Factor, ASCE 7-16 Table 13.6-1) z 0 h 1 Fp 0.4 apSDS Rp Ie   1 2 z h 0.25(ASCE 7-16 Equation 13.3-1) Fp.min 0.3 SDSIe0.47(ASCE 7-16 Equation 13.3-2) (ASCE 7-16 Equation 13.3-3)Fp.max 1.6 SDSIe2.48 Fp min max Fp Fp.min Fp.max 0.47 Fv 0.2 SDS0.21 EV SWBD-1 Eh1 Fp DL1weq1 leq1 1024 lb(Horizontal Seismic Force, ASCE 7-16 Section 13.3.1.1) Mh1 Eh1 hg1 2 3 heq1 5.12 kip ft Ev1 Fv DL1weq1 leq1 455 lb(Vertical Seismic Force, ASCE 7-16 Section 13.3.1.2) EV SWBD-2 Eh2 Fp DL2 weq2 leq2 206 lb(Horizontal Seismic Force, ASCE 7-16 Section 13.3.1.1) Mh2 Eh2 hg2 2 3 heq2 0.73 kip ft Ev2 Fv DL2 weq2 leq2 91 lb(Vertical Seismic Force, ASCE 7-16 Section 13.3.1.2) 150kVA Transformer Eh3 Fp DL3 weq3 leq3 537 lb(Horizontal Seismic Force, ASCE 7-16 Section 13.3.1.1) Page: 4 of 5 909 N Grand Ave - 101116238 & 201806132/15/2024 Structural Calculations Charge Ready Program Date: 10/27/2023 Calculated by: MM Checked By: DPB Mh3 Eh3 hg3 2 3 heq3 1.33 kip ft Ev3 Fv DL3 weq3 leq3 239 lb(Vertical Seismic Force, ASCE 7-16 Section 13.3.1.2) IV. Anchor Design Note: Anchor Design is performed in Hilti Profis. The anchors pass all checks. EV SWBD-1 Pu 0.9Weq1 Ω Ev10.89 kip Vu max Wx1 Wz1Ω Eh1 2.05 kipAnchor Loading; Conservatively use envelope loading Mu max M x1 Mz1Ω M h1 10.24 kip ft EV SWBD-2 Pu 0.9Weq2 Ω Ev20.18 kip Vu max Wx2 Wz2Ω Eh2 0.41 kipAnchor Loading; Conservatively use envelope loading Mu max M x2 Mz2Ω M h2 1.46 kip ft 150kVA Transformer Pu 0.9Weq3 Ω Ev30.47 kip Vu max Wx3 Wz3Ω Eh3 1.07 kipAnchor Loading; Conservatively use envelope loading Mu max M x3 Mz3Ω M h3 2.66 kip ft V. Foundation Design Note: Foundation Design is performed in RISA Foundation. The foundation passes all checks. Page: 5 of 5 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 1.2 RISA Foundation Output Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 Company : NV5 Nov 3, 2023 9:37 AMDesigner : MM Job Number : Charge Ready Program Checked By:_____ Model Name : Pad Foundation Point Coordinates Label Z [ft] X [ft] 1 N1 0 0 2 N2 9 0 3 N3 9 7.5 4 N4 0 7.5 5 N5 1 0.5 6 N6 1 4 7 N7 7.33 0.5 8 N8 7.33 4 9 N9 1.729167 5 10 N10 1.729167 7 11 N11 4.8333 5 12 N12 4.8333 7 13 N13 5.8333 4.5 14 N14 5.8333 7 15 N15 8.5 4.5 16 N16 8.5 7 17 N17 4.16667 2.25 18 N18 3.28125 6 19 N19 7.166667 5.75 20 N20 2.25 5.625 21 N21 0 5.625 22 N22 0 3.75 23 N23 2.25 3.75 24 N24 6.75 1.875 25 N25 9 1.875 26 N26 9 3.75 27 N27 6.75 3.75 28 N28 2.25 1.875 29 N29 4.5 1.875 30 N30 4.5 3.75 31 N31 6.75 5.625 32 N32 4.5 5.625 33 N33 4.5 7.5 34 N34 2.25 7.5 35 N35 4.5 0 36 N36 6.75 0 37 N37 0 1.875 38 N38 2.25 0 39 N39 9 5.625 40 N40 6.75 7.5 Load Combinations Label Solve Servi...AB...SF Ca...Fa...CategoryFa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa... 1 1.4D Yes DL 1.4 2 1.2DL+1.0WL(...Yes DL 1.2 WLX 1 3 1.2DL+1.0WL(...Yes DL 1.2 WLX -1 4 1.2DL+1.0WL(...Yes DL 1.2 WLZ 1 5 1.2DL+1.0WL(...Yes DL 1.2 WLZ -1 6 0.9DL+1.0WL(...Yes DL 0.9 WLX 1 7 0.9DL+1.0WL(...Yes DL 0.9 WLX -1 8 0.9DL+1.0WL(...Yes DL 0.9 WLZ 1 9 0.9DL+1.0WL(...Yes DL 0.9 WLZ -1 10 1.2DL+1.0ELY...Yes DL 1.2 ELY 1 ELX 1 11 1.2DL+1.0ELY...Yes DL 1.2 ELY 1 ELX -1 12 1.2DL+1.0ELY...Yes DL 1.2 ELY 1 ELZ 1 13 1.2DL+1.0ELY...Yes DL 1.2 ELY 1 ELZ -1 14 0.9DL-1.0ELY...Yes DL 0.9 ELY -1 ELX 1 15 0.9DL-1.0ELY...Yes DL 0.9 ELY -1 ELX -1 RISAFoundation Version 15.0.1.29 Page 1 [P:\...\...\...\...\Structural\Calculations\EV-SWBD\EV-SWBD.fnd] 909 N Grand Ave - 101116238 & 201806132/15/2024 Company : NV5 Nov 3, 2023 9:37 AMDesigner : MM Job Number : Charge Ready Program Checked By:_____ Model Name : Pad Foundation Load Combinations (Continued) Label Solve Servi...AB...SF Ca...Fa...CategoryFa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa... 16 0.9DL-1.0ELY...Yes DL 0.9 ELY -1 ELZ 1 17 0.9DL-1.0ELY...Yes DL 0.9 ELY -1 ELZ -1 18 1.0DL Yes Yes DL 1 19 1.0DL+0.6WL(...Yes Yes DL 1 WLX 0.6 20 1.0DL+0.6WL(...Yes Yes DL 1 WLX -0.6 21 1.0DL+0.6WL(...Yes Yes DL 1 WLZ 0.6 22 1.0DL+0.6WL(...Yes Yes DL 1 WLZ -0.6 23 0.6DL+0.6WL(...Yes Yes DL 0.6 WLX 0.6 24 0.6DL+0.6WL(...Yes Yes DL 0.6 WLX -0.6 25 0.6DL+0.6WL(...Yes Yes DL 0.6 WLZ 0.6 26 0.6DL+0.6WL(...Yes Yes DL 0.6 WLZ -0.6 27 1.0DL+0.7ELY...Yes Yes DL 1 ELY 0.7 ELX 0.7 28 1.0DL+0.7ELY...Yes Yes DL 1 ELY 0.7 ELX -0.7 29 1.0DL+0.6ELY...Yes Yes DL 1 ELY 0.7 ELZ 0.7 30 1.0DL+0.7ELY...Yes Yes DL 1 ELY 0.7 ELZ -0.7 31 0.6DL-0.7ELY...Yes Yes DL 0.6 ELY -0.7 ELX 0.7 32 0.6DL-0.7ELY...Yes Yes DL 0.6 ELY -0.7 ELX -0.7 33 0.6DL-0.7ELY...Yes Yes DL 0.6 ELY -0.7 ELZ 0.7 34 0.6DL-0.7ELY...Yes Yes DL 0.6 ELY -0.7 ELZ -0.7 Area Loads (Cat 1 : DL) Label Base Mag[ksf] Peak Mag[ksf] 1 AL1 0.099 0.099 2 AL2 0.066 0.066 3 AL3 0.186 0.186 Point Loads and Moments (Cat 16 : ELX) Label Direction Magnitude[k,k-ft] 1 N17 X 1.024 2 N19 X 0.206 3 N18 X 0.537 4 N17 MZ -5.12 5 N19 MZ -0.73 6 N18 MZ -1.33 Point Loads and Moments (Cat 17 : ELY) Label Direction Magnitude[k,k-ft] 1 N17 Y 0.455 2 N19 Y 0.091 3 N18 Y 0.239 Point Loads and Moments (Cat 18 : ELZ) Label Direction Magnitude[k,k-ft] 1 N17 Z 1.024 2 N19 Z 0.206 3 N18 Z 0.537 4 N17 MX 5.12 5 N19 MX 0.73 6 N18 MX 1.33 Point Loads and Moments (Cat 19 : WLX) Label Direction Magnitude[k,k-ft] 1 N17 X 0.943 2 N19 X 0.283 3 N18 X 0.183 4 N17 MZ -3.54 RISAFoundation Version 15.0.1.29 Page 2 [P:\...\...\...\...\Structural\Calculations\EV-SWBD\EV-SWBD.fnd] 909 N Grand Ave - 101116238 & 201806132/15/2024 Company : NV5 Nov 3, 2023 9:37 AMDesigner : MM Job Number : Charge Ready Program Checked By:_____ Model Name : Pad Foundation Point Loads and Moments (Cat 19 : WLX) (Continued) Label Direction Magnitude[k,k-ft] 5 N19 MZ -0.75 6 N18 MZ -0.36 Point Loads and Moments (Cat 21 : WLZ) Label Direction Magnitude[k,k-ft] 1 N17 Z 0.521 2 N19 Z 0.265 3 N18 Z 0.183 4 N17 MX 1.96 5 N19 MX 0.71 6 N18 MX 0.321 Soil Definitions Label Subgrade Modulus[k/ft^3] Allowable Bearing[ksf] Depth Properties Default? 1 Default 100 1 None Yes Concrete Properties Label E [ksi] G [ksi] Nu Therm (/1E...Density[k/ft... f'c[ksi] Lambda Flex Steel[...Shear Stee... 1 Conc3000NW 3156 1372 0.15 0.6 0.145 3 1 60 60 2 Conc3500NW 3409 1482 0.15 0.6 0.145 3.5 1 60 60 3 Conc4000NW 3644 1584 0.15 0.6 0.145 4 1 60 60 4 Conc3000LW 2085 907 0.15 0.6 0.11 3 0.75 60 60 5 Conc3500LW 2252 979 0.15 0.6 0.11 3.5 0.75 60 60 6 Conc4000LW 2408 1047 0.15 0.6 0.11 4 0.75 60 60 Slabs Label Thickness [in] Material Local Axis Angle...Analysis Offset [i...Passive Pressur...Soil Overburden ...Icr Factor 1 S1 8 Conc3000NW 0 0 0 0 0.25 Slab Rebar Parameters Label Top ... Bottom...Max Top B...Min Top Ba...Max Bot Ba...Min Bot Bar S... Spacing Incre... Side Cover[in] Rebar Options 1 Typical N/A #5 N/A N/A 12 12 3 3 Mid-Depth Only Design Strips Label Rebar Angle from P... No. of Design Cuts Design Rule 1 DS1 0 50 Typical 2 DS2 90 50 Typical Envelope Slab Soil Pressures Label Max UC Max LC Soil Pressure[ksf] Allowable Bearing[ksf] Point 1 S1 0.221 27 0.221 1 N34 Strip Reinforcing Label UC Top LC Top Bars Governin... UC Bot LC Bot Bars/...Governin... UC Shear LC Governin... 1 DS1 0.056 17 0.108 12 #5@12in DS1-X26 0.051 12 DS1-X37 2 DS2 0.052 15 0.063 10 #5@12in DS2-X14 0.041 10 DS2-X25 Slab Overturning Safety Factors LC Slab Angle[deg] Mo-xx[k-ft] Ms-xx[k-ft] Mo-zz[k-ft] Ms-zz[k-ft] Ms-xx/Mo-xx Ms-zz/Mo-zz 1 18 S1 0 0 45.44 0 38.486 9.99+9.99+ 2 19 S1 0 0 45.44 3.354 38.486 9.99+9.99+ 3 20 S1 0 0 45.44 3.354 38.862 9.99+9.99+ 4 21 S1 0 2.182 47.378 0 38.486 9.99+9.99+ 5 22 S1 0 2.182 45.44 0 38.486 9.99+9.99+ 6 23 S1 0 0 27.264 3.354 23.092 9.99+6.886 RISAFoundation Version 15.0.1.29 Page 3 [P:\...\...\...\...\Structural\Calculations\EV-SWBD\EV-SWBD.fnd] 909 N Grand Ave - 101116238 & 201806132/15/2024 Company : NV5 Nov 3, 2023 9:37 AMDesigner : MM Job Number : Charge Ready Program Checked By:_____ Model Name : Pad Foundation Slab Overturning Safety Factors (Continued) LC Slab Angle[deg] Mo-xx[k-ft] Ms-xx[k-ft] Mo-zz[k-ft] Ms-zz[k-ft] Ms-xx/Mo-xx Ms-zz/Mo-zz 7 24 S1 0 0 27.264 3.354 23.317 9.99+6.953 8 25 S1 0 2.182 28.427 0 23.092 9.99+9.99+ 9 26 S1 0 2.182 27.264 0 23.092 9.99+9.99+ 10 27 S1 0 0 47.773 5.851 40.52 9.99+6.926 11 28 S1 0 0 47.773 5.851 40.949 9.99+6.999 12 29 S1 0 5.851 49.991 0 40.52 8.545 9.99+ 13 30 S1 0 5.851 47.773 0 40.52 8.165 9.99+ 14 31 S1 0 2.613 28.427 7.885 23.092 9.99+2.928 15 32 S1 0 2.613 28.427 7.937 23.317 9.99+2.938 16 33 S1 0 8.464 28.427 2.087 23.317 3.359 9.99+ 17 34 S1 0 8.183 27.264 2.087 23.317 3.332 9.99+ Slab Sliding Safety Factors LC Slab Angle[deg] Va-xx[k] Vr-xx[k] Va-zz[k] Vr-zz[k] SR-xx SR-zz 1 18 S1 0 0 3.094 0 3.094 9.99+9.99+ 2 19 S1 0 0.845 3.094 0 3.094 3.66 9.99+ 3 20 S1 0 0.845 3.094 0 3.094 3.66 9.99+ 4 21 S1 0 0 3.094 0.581 3.094 9.99+5.322 5 22 S1 0 0 3.094 0.581 3.094 9.99+5.322 6 23 S1 0 0.845 1.856 0 1.856 2.196 9.99+ 7 24 S1 0 0.845 1.856 0 1.856 2.196 9.99+ 8 25 S1 0 0 1.856 0.581 1.856 9.99+3.193 9 26 S1 0 0 1.856 0.581 1.856 9.99+3.193 10 27 S1 0 1.237 3.259 0 3.259 2.635 9.99+ 11 28 S1 0 1.237 3.259 0 3.259 2.635 9.99+ 12 29 S1 0 0 3.259 1.237 3.259 9.99+2.635 13 30 S1 0 0 3.259 1.237 3.259 9.99+2.635 14 31 S1 0 1.237 1.692 0 1.692 1.368 9.99+ 15 32 S1 0 1.237 1.692 0 1.692 1.368 9.99+ 16 33 S1 0 0 1.692 1.237 1.692 9.99+1.368 17 34 S1 0 0 1.692 1.237 1.692 9.99+1.368 RISAFoundation Version 15.0.1.29 Page 4 [P:\...\...\...\...\Structural\Calculations\EV-SWBD\EV-SWBD.fnd] 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 1.3 Anchorage Design Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | EV SWBD-1 Anchor Design Page: Specifier: E-Mail: Date: 1 10/27/2023 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 316 1/2 (3 1/4) hnom3 Item number: 2210266 KB-TZ2 1/2x5 1/2 SS316 Effective embedment depth: hef,act = 3.250 in., hnom = 3.750 in. Material: AISI 316 Evaluation Service Report: ESR-4266 Issued I Valid: 12/17/2021 | 12/1/2023 Proof: Design Method ACI 318-14 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plateR : lx x ly x t = 80.500 in. x 25.500 in. x 0.500 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 3000, fc' = 3,000 psi; h = 8.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: > No. 4 bar with stirrups Seismic loads (cat. C, D, E, or F) Tension load: yes (17.2.3.4.3 (d)) Shear load: yes (17.2.3.5.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [kip, ft.kip] 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | EV SWBD-1 Anchor Design Page: Specifier: E-Mail: Date: 2 10/27/2023 1.1 Design results Case Description Forces [kip] / Moments [ft.kip]Seismic Max. Util. Anchor [%] 1 Combination 1 N = -0.890; Vx = 0.000; Vy = 2.050; Mx = -10.24000; My = 0.00000; Mz = 0.00000; yes 51 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | EV SWBD-1 Anchor Design Page: Specifier: E-Mail: Date: 3 10/27/2023 2 Proof I Utilization (Governing Cases) Design values [kip] Utilization Loading Proof Load Capacity bN / b V [%]Status Tension Concrete Breakout Failure 4.959 9.812 51 / - OK Shear Concrete edge failure in direction x- 2.050 17.844 - / 12 OK Loading bN bV z Utilization bN,V [%]Status Combined tension and shear loads 0.505 0.115 5/3 35 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | EV SWBD-1 Anchor Design Page: Specifier: E-Mail: Date: 4 10/27/2023 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | EV SWBD-2 Anchor Design Page: Specifier: E-Mail: Date: 1 10/25/2023 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 316 5/8 (3 1/4) hnom2 Item number: 2210306 KB-TZ2 5/8x6 SS316 Effective embedment depth: hef,act = 3.250 in., hnom = 3.750 in. Material: AISI 316 Evaluation Service Report: ESR-4266 Issued I Valid: 12/17/2021 | 12/1/2023 Proof: Design Method ACI 318-14 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plateR : lx x ly x t = 32.000 in. x 30.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 3000, fc' = 3,000 psi; h = 8.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: > No. 4 bar with stirrups Seismic loads (cat. C, D, E, or F) Tension load: yes (17.2.3.4.3 (d)) Shear load: yes (17.2.3.5.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [kip, ft.kip] 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | EV SWBD-2 Anchor Design Page: Specifier: E-Mail: Date: 2 10/25/2023 1.1 Design results Case Description Forces [kip] / Moments [ft.kip]Seismic Max. Util. Anchor [%] 1 Combination 1 N = -0.180; Vx = 0.000; Vy = 0.410; Mx = -1.46000; My = 0.00000; Mz = 0.00000; yes 15 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | EV SWBD-2 Anchor Design Page: Specifier: E-Mail: Date: 3 10/25/2023 2 Proof I Utilization (Governing Cases) Design values [kip] Utilization Loading Proof Load Capacity bN / b V [%]Status Tension Concrete Breakout Failure 0.581 3.928 15 / - OK Shear Concrete edge failure in direction y+ 0.410 8.586 - / 5 OK Loading bN bV z Utilization bN,V [%]Status Combined tension and shear loads 0.148 0.048 5/3 5 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | EV SWBD-2 Anchor Design Page: Specifier: E-Mail: Date: 4 10/25/2023 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | XFMR Anchor Design Page: Specifier: E-Mail: Date: 1 10/25/2023 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 316 1/2 (3 1/4) hnom3 Item number: 2210266 KB-TZ2 1/2x5 1/2 SS316 Effective embedment depth: hef,act = 3.250 in., hnom = 3.750 in. Material: AISI 316 Evaluation Service Report: ESR-4266 Issued I Valid: 12/17/2021 | 12/1/2023 Proof: Design Method ACI 318-14 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plateR : lx x ly x t = 38.300 in. x 25.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 3000, fc' = 3,000 psi; h = 8.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: > No. 4 bar with stirrups Seismic loads (cat. C, D, E, or F) Tension load: yes (17.2.3.4.3 (d)) Shear load: yes (17.2.3.5.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [kip, ft.kip] 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | XFMR Anchor Design Page: Specifier: E-Mail: Date: 2 10/25/2023 1.1 Design results Case Description Forces [kip] / Moments [ft.kip]Seismic Max. Util. Anchor [%] 1 Combination 1 N = -0.470; Vx = 0.000; Vy = 1.070; Mx = -2.66000; My = 0.00000; Mz = 0.00000; yes 35 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | XFMR Anchor Design Page: Specifier: E-Mail: Date: 3 10/25/2023 2 Proof I Utilization (Governing Cases) Design values [kip] Utilization Loading Proof Load Capacity bN / b V [%]Status Tension Concrete Breakout Failure 1.194 3.490 35 / - OK Shear Concrete edge failure in direction y+ 1.070 8.030 - / 14 OK Loading bN bV z Utilization bN,V [%]Status Combined tension and shear loads 0.342 0.133 5/3 21 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | XFMR Anchor Design Page: Specifier: E-Mail: Date: 4 10/25/2023 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 1.4 Equipment Drawing Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 "EV-SWBD-1" 909 N Grand Ave - 101116238 & 201806132/15/2024 = WAGO TYPE CONNECTION = TERMINAL BLOCK = FUSE HOLDER = STRIP HEATER = BLUE PILOT LIGHT = GROUND BUS CONNECTION = CONTROL POWER TRANSFORMER = PLUG TYPE CONNECTION (UT 4/1) = FUSED OPEN TYPE DISCONNECT = WYE POTENTIAL TRANSFORMER CONFIGURATION = BUS TAP = CURRENT TRANSFORMER = NORMALLY OPEN CONTACT = NORMALLY CLOSED CONTACT = TWO POSITIONS DOOR KNOB B = 3-POLE CIRCUIT BREAKER = 2-POLE CIRCUIT BREAKER = 1-POLE CIRCUIT BREAKER = 3-POLE FUSED PRESSURE SWITCH = MECHANICAL LUG = FAN = GFCI RECEPTACLE =NEUTRAL DISCONNECT =UTILITY METERING =RECEPTACLE =90° HINGE =MAINTENANCE MODE SWITCH GND M = VENTILATION = NEMA POSITION = COVER HANDLE = NEUTRAL SENSOR = PHASE NS ɸ 16450 PHOEBE AVENUE LA MIRADA, CA 90638 PHONE: (714)-307-9198 CUSTOMER APPROVAL: #REVISION DATE C:\Users\anhbui.B2SERVER\DesktopPLOT DATE:BY: SHEET DESCRIPTION: PAPER:REV: 8.5"X 11" POWER & DISTRIBUTION 0 FIRST ISSUE SHEET:DRAWN BY: DRAWING: 8/4/2023 8:08 AM ANHBUI 0 8/4/2023 AB 0 Z-POWER & DISTR. SYMBOL LEGEND 909 N Grand Ave - 101116238 & 201806132/15/2024 SEISMIC COMPLIANCE: DEV MIN. SC RATING: WIRE: PHASE: BUS BRACED: BUS MATERIAL: CURRENT RATING: SERVICE VOLTAGE: FINISH PAINT: CONSTRUCTION: SPECIFICATIONS COMPLIANCE: BASE PARTS MADE OF: UL FILE E337533 EQUIPMENT RATED: UL TYPE 3R, OUTDOOR CARDINAL P004-GR16 GRAY, ANSI# 61 480Y/227VAC 3 4 1000A PLATED ALUMINUM 750A PER SQ IN 65KAIC 65KAIC EQUIPMENT SHALL BEAR THE UL 891 LABEL SUITABLE FOR USE AS SERVICE EQUIPMENT OSHPD #OSP-0308-10 10 GAUGE GALV. STEEL ESR 333 320 347, 327 345 326, 354 EUSERC METER DOOR CT COMPARTMENT UGPS TERMINATIONS UGPS CONSTRUCTION 6-4,6-30 6-19, 6-20 6-12, 6-13 6-14, 6-15, 6-16 6-8, 10 POWER COMPANY: SCE PAD LOCKABLE CIRCUIT BREAKER X-BUX TO FOLLOW EUSERC SECT. 300, METERING & SERVICING EQUIPMENT, FIG. 1 ON SHEET 12 OF 19 45"45" 40"40" 5"5" 13.00 6.75 28.00 UL891/SUSE GB 42.00 20" 3" 41" 15" 11" 28X FRONT ELEVATION SHOWN WITH 3R COMPONENTS REMOVED FOR CLARITY LEFT ELEVATION SHOWN WITH 3R COMPONENTS REMOVED FOR CLARITY WEIGHT ≈ 2000LBS. 28.00 45" 40" 5" RIGHT ELEVATION SHOWN WITH 3R COMPONENTS REMOVED FOR CLARITY 52-M 1600AF 1000AT 3-POLE LSIG 100% SCE TERMINATIONS (3)POSITIONS PER ɸ & N 1000A, 3ɸ 4W, 480Y/227VAC, 65KAIC, AL xxM UTILITY METERING NEUTRAL DISCONNECT MAIN BONDING JUMPER (1)3/0AWG 75°C CU (FIELD INSTALLABLE) 250/3 250/3 52-M 1000/3 40.25" TO TERMINATION BOLT 90.00 400/3 NS NS 22.50 400/3 30.00 ACCESS OPENING UL891 34.00 12" UGPS AND TERMINATION COMPARTMENT EUSERC 327, 345, & 347 SH1 19.50 33.50 CONDUIT AREA 19.50 25.50 UTILITY CONDUIT AREA 3R EXTENSION 28.00 14.00 76.00 FRONT 400/3 400/3 15C 15C METER DOOR EUSERC 333 CT COMPT. EUSERC 320 MM SI T E N A M E / L O C A T I O N : 16450 PHOEBE AVENUE LA MIRADA, CA 90638 PHONE: (714)-307-9198 CUSTOMER APPROVAL: #REVISION DATE Z:\Z-Power_Projects\SCE - ALL\SCE_Charge-Ready_ALL\909 N Grand Ave, Santa Ana_16362PLOT DATE:BY: SHEET DESCRIPTION: PAPER:REV: 8.5"X 11" POWER & DISTRIBUTION 0 ISSUED FOR APPROVAL SHEET:DRAWN BY: DRAWING: SC E C H A R G E R E A D Y - A S P U L N D H TO M ' S T R U C K C E N T E R # 2 90 9 N G R A N D A V E SA N T A A N A , C A 9 2 7 0 1 9/10/2023 9:06 AM LENAPAULOS 1A 09/10/23 LP 0 2309-3-16362A "EV-SWBD-1" ELEVATIONS/SPECS. 909 N Grand Ave - 101116238 & 201806132/15/2024 ANCHOR LOCATION DIMENSIONS - SIDES OPTION ANCHOR LOCATION DIMENSIONS - FRONT AND BACK OPTION 3R EXTENSION 3R EXTENSION 3.75 13.25 13.25 7.50 17.25 17.25 3.75 3.25 21.50 3.25 3.25 27.50 6.50 35.50 3.25 7.25 6.75 6.75 7.25 .562Ø TYP. 1.ALL CURRENT TRANSFORMER, HEATER, AND RECEPTACLE WIRING TO BE #12AWG CU SIS WIRE 90°C (UNLESS OTHERWISE INDICATED) 2.ALL OTHER WIRING CONNECTIONS TO BE #14AWG CU SIS WIRE 90°C (UNLESS OTHERWISE INDICATED) X4 X2H2 X1H1 H4 H3 X3 +V -V POWER SUPPLY 120VAC - 24VDC L N -V POWER SUPPLY 120VAC - 24VDC L N F1 2A F3 1/2A1/2A 480V FROM Aɸ AND Bɸ BUS TAPS ON LOAD SIDE OF 52-M 5A F2 X1 SH1TH HUM X2 24+ 24- X1 X2 PS CPT 500VA 480V-120V L1 L2 #12AWG BLACK BLACK WHITE X2 BROWN ORANGE #12AWG TH #12AWG RED SET TH 60°F HUM TO 40% #14AWG WHITE #14AWG H1 H4 #14AWG BLACK 1 2#12AWG HIGH-TEMP TB-SH1 TB-SH1 SH X1 X2 #14AWG GREY #14AWG BLUE GREEN #12AWG WHITE 24+ 24- GND B21 B22 B27 B28 B1 B2 NEUT SENSOR B19 B20 MAINTENANCE MODE SWITCH B ON TEST SW 24- ON SW 24+ 52-M TERMINAL BLOCK BLUE PURPLE GREY BLACK #14AWG #12AWG BLACK #12AWG WHITE HIGH COM -+ 34 12 24+ 24- SI T E N A M E / L O C A T I O N : 16450 PHOEBE AVENUE LA MIRADA, CA 90638 PHONE: (714)-307-9198 CUSTOMER APPROVAL: #REVISION DATE Z:\Z-Power_Projects\SCE - ALL\SCE_Charge-Ready_ALL\909 N Grand Ave, Santa Ana_16362PLOT DATE:BY: SHEET DESCRIPTION: PAPER:REV: 8.5"X 11" POWER & DISTRIBUTION 0 ISSUED FOR APPROVAL SHEET:DRAWN BY: DRAWING: SC E C H A R G E R E A D Y - A S P U L N D H TO M ' S T R U C K C E N T E R # 2 90 9 N G R A N D A V E SA N T A A N A , C A 9 2 7 0 1 9/10/2023 9:06 AM LENAPAULOS 2A 09/10/23 LP 0 2309-3-16362A ANCHORING / CONTROL WIRING 909 N Grand Ave - 101116238 & 201806132/15/2024 www.zpoweranddistribution.com (714) 307-9198 ITEM QTY.MFG CAT. No.DESCRIPTION REV 1600AF 1000AT LSIG 1 GE SSF2G5B3U000008 1600AF, 1600AS 3P INSULATED CASE BREAKER 65KAIC @480VAC 100KAIC @240VAC 100%, FIXED TYPE MANUAL OPERATOR, INCLUDING: 1600A RATING PLUG, ENTELLIGUARD TRIP UNIT LSIG TRIP UNIT, MODBUS RELT, INTEGRATED PADLOCK (CHANGE OUT 1000A RATING PLUG) 1 GE TSVG816A NEUTRAL SENSOR 1 GE GTP1000U1025 1000A RATING PLUG MM 1 SQ D 9001K11J35LLL SWITCH WITH BLUE INDICATOR LIGHT (24VDC) 400/3 2 EATON PDG33M0400TFAN POWER DEFENSE GLOBALLY RATED, FRAME 3, THREE POLE, 400A, 65KA/480V, T-M (FXD-ADJ) TU, NO TERMINALS 6 EATON PDG3X3TA400 (2)3/0AWG-250MCM CU/AL LUG 2 EATON PDG3XPLKROFF PADLOCK PROVISION 250/3 1 EATON PDG33M0400B2NN SERIES C MCCB, FRAME K, THREE POLE, 400A, 65KVA/480V, ADJ TRIP, TRIP SET AT 250A 3 EATON PDG3X3TA400 400A, 3P, (2) 3/0 AWG-250 KCMIL CU/AL,TWO-WIRE, ALUMINUM 1 EATON PDG3XPLKTOFF PADLOCK PROVISION F1 1 FERRAZ USCC2I 600V 30A 2-POLE FUSE BLOCK 1 MERSEN ATQR2 2A FUSE CLASS CC, TIME-DELAY F2 1 FERRAZ USCC1I 600V 30A 1-POLE FUSE BLOCK 1 MERSEN ATQR5 5A FUSE CLASS CC, TIME-DELAY F3 1 FERRAZ USCC1I 600V 30A 1-POLE FUSE BLOCK 1 MERSEN ATQR1/2 1/2A FUSE CLASS CC, TIME-DELAY TH 1 HONEYWELL T410A THERMOSTAT 50-90 F, 22A HUM 1 BROAN DD500W DE-HUYMIDISTAT 20-80% RH SH 1 TEMPCO CSF00500 STRIP HEATER 350W, 120V 15CL 2 MARKWELL CFI1015CT-B 15 CLIP METER SOCKET, XFMR RATED 400A 2 SQ D H365NR SAFETY SWITCH, HEAVY DUTY, FUSIBLE, 400A, 3 POLES, 500 HP, 600 VAC/DC, NEMA 3R, NEUTRAL FACTORY INSTALLED 6 FERRAZ TRS400R 600V 400A FUSE TRI-ONIC® 600V TIME-DELAY CLASS RK5 TR 100A 3 SQ D H363RB SAFETY SWITCH, HEAVY DUTY, FUSIBLE, 100A, 3 POLES, 500 HP, 600 VAC/DC, NEMA 3R, NEUTRAL FACTORY INSTALLED 9 FERRAZ TR100R 240V 100A FUSE TRI-ONIC® 600V TIME-DELAY CLASS RK5 TR CPT 1 AMRAN PH500MQMJ CONTROL POWER TRANSFORMER ITEMS TO SHIP LOOSE PREPARED BY : LP BILL OF MATERIALS SCE CHARGE READY - ASPLUNDH 909 N GRAND AVE SANTA ANA, CA 92701 Drawing No. 2309-3-16362_BM 909 N Grand Ave - 101116238 & 201806132/15/2024 "EV-SWBD-2" 909 N Grand Ave - 101116238 & 201806132/15/2024 ACCESS FRONT DOOR 30.00 PA N E L 64.00 32.00 SIDE SECTIONAL VIEW FRONT ELEVATION SHOWN WITH 3R DOOR REMOVED FOR CLARITY ACCESS DOOR 32.00 21.88 28.00 CONDUIT AREA 28.00 6.13 1.00 30.00 0.75" X 2" ANCHOR HOLES TYP (4) 2.38 24.25 2.37 1.00 52-M 500/3 30CKT PANEL SEISMIC COMPLIANCE: DEV MIN. SC RATING: WIRE: PHASE: BUS BRACED: BUS MATERIAL: CURRENT RATING: SERVICE VOLTAGE: FINISH PAINT: CONSTRUCTION: SPECIFICATIONS COMPLIANCE: BASE PARTS MADE OF: UL FILE E337533 EQUIPMENT RATED: UL FILE E475911 EQUIPMENT RATED: UL TYPE 3R, OUTDOOR CARDINAL P004-GR16 GRAY, ANSI #61 208Y/120VAC 3 4 600A PLATED COPPER 1000A PER SQ IN 42KAIC 42KAIC EQUIPMENT SHALL BEAR THE UL 891 LABEL N/A OSHPD #OSP-0308-10 10 GAUGE GALV. STEEL INTERIOR SHALL BEAR THE UL 67 LABEL 52-M 500A 3-POLE LI 80% FROM EV-XFMR 30CKT PANEL SEE SHEET 2B FOR DETAILS (1)373-01 DLO CU 90°C PER ɸ & NFRONT ELEVATION WEIGHT ≈ 402 LBS. SI T E N A M E / L O C A T I O N : 16450 PHOEBE AVENUE LA MIRADA, CA 90638 PHONE: (714)-307-9198 CUSTOMER APPROVAL: #REVISION DATE Z:\Z-Power_Projects\SCE - ALL\SCE_Charge-Ready_ALL\909 N Grand Ave, Santa Ana_16362PLOT DATE:BY: SHEET DESCRIPTION: PAPER:REV: 8.5"X 11" POWER & DISTRIBUTION 0 ISSUED FOR APPROVAL SHEET:DRAWN BY: DRAWING: SC E C H A R G E R E A D Y - A S P U L N D H TO M ' S T R U C K C E N T E R # 2 90 9 N G R A N D A V E SA N T A A N A , C A 9 2 7 0 1 9/10/2023 9:06 AM LENAPAULOS 1B 09/10/23 LP 0 2309-3-16362B "EV-SWBD-2" ELEVATIONS/SPECS. 909 N Grand Ave - 101116238 & 201806132/15/2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 MCB 500/3 19 20 21 22 23 24 25 26 27 28 29 30 A B C 31 32 33 34 35 36 37 38 39 40 41 42 100/3 FROM EV-XFMR INTERIOR INFO. AEU3426RCXAXB4 (600A, 42CKT, 3ɸ) MAIN DESCRIPTION CURRENT: 500 AMPS POLES: 3 POLES TYPE MAIN BREAKER CAT#: PDG33M0600B2NN (SET @500AT) PADLOCK: PDG3XPLTOFF BRANCH DEVICES Qty Amps/P Cat# 4 100A/3P TEY3100 4 20A/1P TEY120 100/3 100/3 100/3 20/1 20/1 20/1 20/1 SI T E N A M E / L O C A T I O N : 16450 PHOEBE AVENUE LA MIRADA, CA 90638 PHONE: (714)-307-9198 CUSTOMER APPROVAL: #REVISION DATE Z:\Z-Power_Projects\SCE - ALL\SCE_Charge-Ready_ALL\909 N Grand Ave, Santa Ana_16362PLOT DATE:BY: SHEET DESCRIPTION: PAPER:REV: 8.5"X 11" POWER & DISTRIBUTION 0 ISSUED FOR APPROVAL SHEET:DRAWN BY: DRAWING: SC E C H A R G E R E A D Y - A S P U L N D H TO M ' S T R U C K C E N T E R # 2 90 9 N G R A N D A V E SA N T A A N A , C A 9 2 7 0 1 9/10/2023 9:06 AM LENAPAULOS 2B 09/10/23 LP 0 2309-3-16362B PANEL WIRING 909 N Grand Ave - 101116238 & 201806132/15/2024 150KVA XFMR 909 N Grand Ave - 101116238 & 201806132/15/2024 909 N Grand Ave - 101116238 & 201806132/15/2024 909 N Grand Ave - 101116238 & 201806132/15/2024 909 N Grand Ave - 101116238 & 201806132/15/2024 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 2.0 100A-SW Foundation Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 2.1 Foundation Design Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 Structural Calculations Charge Ready Program Date: 10/27/2023 Calculated by: MM Checked By: DPB 100A SW - Structural Calculation _________________________________________________________________________ I. References 1. ASCE 7-16 2. Schneider Electric Single Throw Safety Switch, 100A, 600V II. Equipment Information weq 6.38in(Width of Equipment) leq 10.25in(Length of Equipment) h eq 21.25in(Height of Equipment) Weq 17.46lb(Weight of Equipment) h g 18in(Height above Ground; Assumed) n 2(Number of Posts) s 1ft(Spacing of Posts; Assumed) III. Equipment Loading Dead Load: SF 1.5(Safety Factor to Account for Misc Parts) DL Weq SF n 13.10 lb(Dead Load at Base of Post) Wind Load: V 95mph(Basic Wind Speed: Risk Category II) Exposure Category C k d 0.85(ASCE Table 26.6-1) k zt 1.0(ASCE 7-16 Section 26.8.1) k e 1.0(ASCE Table 26.9-1) k z 0.85(ASCE Table 26.10-1) Gf 0.85(ASCE Equation 26.10-1) Page: 1 of 4 909 N Grand Ave - 101116238 & 201806132/15/2024 Structural Calculations Charge Ready Program Date: 10/27/2023 Calculated by: MM Checked By: DPB Cf 1.4(ASCE Figure 29.4-1) (Design Wind Pressure)q z 0.00256 kzk ztkdkeV2 lb ft2 mph2   16.69 lb ft2 Wx Gf Cfqzweqh eq18.70 lb(Force due to Wind in X-Direction) Wz Gf Cfqzleqh eq30.05 lb(Force due to Wind in Z-Direction) Reactions due to Wind in X-Direction: Rx1 Wx n 9.35 lb(Shear Reaction at Base of Post) Fy1 Wx h g h eq 2  s n22.31 lb(Vertical Reaction at Base of Post; One Post in Compression; One in Uplift) Reactions due to Wind in Z-Direction: Rz1 Wz n 15.02 lb(Shear Reaction at Base of Post) Mx1 Wx n h g heq 2 22.31 lb ft(Moment Reaction at Base of Post) Seismic Load: SDS 1.034(Spectral Acceleration, short period, ASCE 7-16 Section 11.4.5) SD1 0.461(Spectral Acceleration,1s period, ASCE 7-16 Section 11.4.6) Ie 1.5(Importance Factor, ASCE 7-16 Section 13.1.3) ap 1.0(Amplification Factor, ASCE 7-16 Table 13.6-1) Rp 2.5(Response Modification Factor, ASCE 7-16 Table 13.6-1) Ω 2(Overstrength Factor, ASCE 7-16 Table 13.6-1) z 0 Page: 2 of 4 909 N Grand Ave - 101116238 & 201806132/15/2024 Structural Calculations Charge Ready Program Date: 10/27/2023 Calculated by: MM Checked By: DPB h 1 Fp 0.4 apSDS Rp Ie   1 2 z h 0.25(ASCE 7-16 Equation 13.3-1) Fp.min 0.3 SDSIe0.47(ASCE 7-16 Equation 13.3-2) (ASCE 7-16 Equation 13.3-3)Fp.max 1.6 SDSIe2.48 Fp min max Fp Fp.min Fp.max 0.47 Fv 0.2 SDS0.21 Eh Fp DL6 lb(Horizontal Seismic Force, ASCE 7-16 Section 13.3.1.1) Ev Fv DL3 lb(Vertical Seismic Force, ASCE 7-16 Section 13.3.1.2) Reactions due to Seismic in X-Direction: Rx2 Eh n 3.05 lb(Shear Reaction at Base of Post) Fy2 Eh hg heq 2  s n7.27 lb(Vertical Reaction at Base of Post; One Post in Compression; One in Uplift) Reactions due to Seismic in Z-Direction: Rz2 Eh n 3.05 lb(Shear Reaction at Base of Post) Mx2 Eh n h g h eq 2 7.27 lb ft(Moment Reaction at Base of Post) Reactions due to Seismic in Y-Direction: Fv Ev n 1.35 lb(Vertical Reaction at Base of Post due to Vertical Seismic Force) IV. Post Design Mu.max max M x1 M x2 22.31 lb ft Page: 3 of 4 909 N Grand Ave - 101116238 & 201806132/15/2024 Structural Calculations Charge Ready Program Date: 10/27/2023 Calculated by: MM Checked By: DPB Sx 0.202in3(Section Modulus; Per Unistrut Manual) σ 3300 lb in2(Yield Stress of Unistrut) Mn σ Sx55.55 lb ft ϕ 0.9 (Moment Capacity of Unistrut)ϕMn ϕ Mn 49.99 lb ft Check if ϕMn Mu.max"OK""No Good" "OK" V. Anchor Design Note: Anchor Design is performed in Hilti Profis. Seismic loads are multiplied by the overload factor. The anchors passes all checks. Vi. Foundation Design Note: Foundation Design is performed in RISA Foundation. The foundation passed all checks. Page: 4 of 4 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 2.2 RISA Foundation Output Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 Company : NV5 Nov 3, 2023 9:19 AMDesigner : MM Job Number : Charge Ready Program Checked By:_____ Model Name : Pad Foundation Point Coordinates Label Z [ft] X [ft] 1 N1 0 0 2 N2 1.5 0 3 N3 1.5 2 4 N4 0 2 5 N5 0.75 0.5 6 N6 0.75 1.5 7 N7 0.75 1 8 N8 0.75 2 9 N9 0 1. 10 N10 0.75 0 11 N11 1.5 1. Load Combinations Label Solve Servi...AB...SF Ca...Fa...CategoryFa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa... 1 1.4D Yes DL 1.4 2 1.2DL+1.0WL(...Yes DL 1.2 WLX 1 3 1.2DL+1.0WL(...Yes DL 1.2 WLX -1 4 1.2DL+1.0WL(...Yes DL 1.2 WLZ 1 5 1.2DL+1.0WL(...Yes DL 1.2 WLZ -1 6 0.9DL+1.0WL(...Yes DL 0.9 WLX 1 7 0.9DL+1.0WL(...Yes DL 0.9 WLX -1 8 0.9DL+1.0WL(...Yes DL 0.9 WLZ 1 9 0.9DL+1.0WL(...Yes DL 0.9 WLZ -1 10 1.2DL+1.0ELY...Yes DL 1.2 ELY 1 ELX 1 11 1.2DL+1.0ELY...Yes DL 1.2 ELY 1 ELX -1 12 1.2DL+1.0ELY...Yes DL 1.2 ELY 1 ELZ 1 13 1.2DL+1.0ELY...Yes DL 1.2 ELY 1 ELZ -1 14 0.9DL-1.0ELY...Yes DL 0.9 ELY -1 ELX 1 15 0.9DL-1.0ELY...Yes DL 0.9 ELY -1 ELX -1 16 0.9DL-1.0ELY...Yes DL 0.9 ELY -1 ELZ 1 17 0.9DL-1.0ELY...Yes DL 0.9 ELY -1 ELZ -1 18 1.0DL Yes Yes DL 1 19 1.0DL+0.6WL(...Yes Yes DL 1 WLX 0.6 20 1.0DL+0.6WL(...Yes Yes DL 1 WLX -0.6 21 1.0DL+0.6WL(...Yes Yes DL 1 WLZ 0.6 22 1.0DL+0.6WL(...Yes Yes DL 1 WLZ -0.6 23 0.6DL+0.6WL(...Yes Yes DL 0.6 WLX 0.6 24 0.6DL+0.6WL(...Yes Yes DL 0.6 WLX -0.6 25 0.6DL+0.6WL(...Yes Yes DL 0.6 WLZ 0.6 26 0.6DL+0.6WL(...Yes Yes DL 0.6 WLZ -0.6 27 1.0DL+0.7ELY...Yes Yes DL 1 ELY 0.7 ELX 0.7 28 1.0DL+0.7ELY...Yes Yes DL 1 ELY 0.7 ELX -0.7 29 1.0DL+0.6ELY...Yes Yes DL 1 ELY 0.7 ELZ 0.7 30 1.0DL+0.7ELY...Yes Yes DL 1 ELY 0.7 ELZ -0.7 31 0.6DL-0.7ELY...Yes Yes DL 0.6 ELY -0.7 ELX 0.7 32 0.6DL-0.7ELY...Yes Yes DL 0.6 ELY -0.7 ELX -0.7 33 0.6DL-0.7ELY...Yes Yes DL 0.6 ELY -0.7 ELZ 0.7 34 0.6DL-0.7ELY...Yes Yes DL 0.6 ELY -0.7 ELZ -0.7 Point Loads and Moments (Cat 1 : DL) Label Direction Magnitude[k,k-ft] 1 N6 Y 0.013 2 N5 Y 0.013 Point Loads and Moments (Cat 16 : ELX) Label Direction Magnitude[k,k-ft] 1 N5 X 0.003 RISAFoundation Version 15.0.1.29 Page 1 [P:\...\...\...\...\Structural\Calculations\100A-SW\100A-SW.fnd] 909 N Grand Ave - 101116238 & 201806132/15/2024 Company : NV5 Nov 3, 2023 9:19 AMDesigner : MM Job Number : Charge Ready Program Checked By:_____ Model Name : Pad Foundation Point Loads and Moments (Cat 16 : ELX) (Continued) Label Direction Magnitude[k,k-ft] 2 N6 X 0.003 3 N5 Y -0.007 4 N6 Y 0.007 Point Loads and Moments (Cat 17 : ELY) Label Direction Magnitude[k,k-ft] 1 N5 Y 0.001 2 N6 Y 0.001 Point Loads and Moments (Cat 18 : ELZ) Label Direction Magnitude[k,k-ft] 1 N5 Z 0.003 2 N6 Z 0.003 3 N5 MX 0.007 4 N6 MX 0.007 Point Loads and Moments (Cat 19 : WLX) Label Direction Magnitude[k,k-ft] 1 N6 X 0.009 2 N5 X 0.009 3 N5 Y -0.022 4 N6 Y 0.022 Point Loads and Moments (Cat 21 : WLZ) Label Direction Magnitude[k,k-ft] 1 N5 Z 0.015 2 N6 Z 0.015 3 N5 MX 0.022 4 N6 MX 0.022 Soil Definitions Label Subgrade Modulus[k/ft^3] Allowable Bearing[ksf] Depth Properties Default? 1 Default 100 1 None Yes Concrete Properties Label E [ksi] G [ksi] Nu Therm (/1E...Density[k/ft... f'c[ksi] Lambda Flex Steel[...Shear Stee... 1 Conc3000NW 3156 1372 0.15 0.6 0.145 3 1 60 60 2 Conc3500NW 3409 1482 0.15 0.6 0.145 3.5 1 60 60 3 Conc4000NW 3644 1584 0.15 0.6 0.145 4 1 60 60 4 Conc3000LW 2085 907 0.15 0.6 0.11 3 0.75 60 60 5 Conc3500LW 2252 979 0.15 0.6 0.11 3.5 0.75 60 60 6 Conc4000LW 2408 1047 0.15 0.6 0.11 4 0.75 60 60 Slabs Label Thickness [in] Material Local Axis Angle...Analysis Offset [i...Passive Pressur...Soil Overburden ...Icr Factor 1 S1 8 Conc3000NW 0 0 0 0 0.25 Slab Rebar Parameters Label Top ... Bottom...Max Top B...Min Top Ba...Max Bot Ba...Min Bot Bar S... Spacing Incre... Side Cover[in] Rebar Options 1 Typical N/A #5 N/A N/A 12 12 3 3 Mid-Depth Only RISAFoundation Version 15.0.1.29 Page 2 [P:\...\...\...\...\Structural\Calculations\100A-SW\100A-SW.fnd] 909 N Grand Ave - 101116238 & 201806132/15/2024 Company : NV5 Nov 3, 2023 9:19 AMDesigner : MM Job Number : Charge Ready Program Checked By:_____ Model Name : Pad Foundation Design Strips Label Rebar Angle from P... No. of Design Cuts Design Rule 1 DS1 0 50 Typical 2 DS2 90 50 Typical Envelope Slab Soil Pressures Label Max UC Max LC Soil Pressure[ksf] Allowable Bearing[ksf] Point 1 S1 0.129 22 0.129 1 N4 Strip Reinforcing Label UC Top LC Top Bars Governin... UC Bot LC Bot Bars/...Governin... UC Shear LC Governin... 1 DS1 0.001 8 0.002 4 #5@12in DS1-X26 0.005 4 DS1-X50 2 DS2 0 N/A 0 1 #5@12in DS2-X26 0 1 DS2-X50 Slab Overturning Safety Factors LC Slab Angle[deg] Mo-xx[k-ft] Ms-xx[k-ft] Mo-zz[k-ft] Ms-zz[k-ft] Ms-xx/Mo-xx Ms-zz/Mo-zz 1 18 S1 0 0 0.237 0 0.316 9.99+9.99+ 2 19 S1 0 0 0.237 0.02 0.316 9.99+9.99+ 3 20 S1 0 0 0.237 0.02 0.316 9.99+9.99+ 4 21 S1 0 0.038 0.237 0 0.316 6.172 9.99+ 5 22 S1 0 0.038 0.237 0 0.316 6.172 9.99+ 6 23 S1 0 0 0.142 0.02 0.19 9.99+9.294 7 24 S1 0 0 0.142 0.02 0.19 9.99+9.294 8 25 S1 0 0.038 0.142 0 0.19 3.703 9.99+ 9 26 S1 0 0.038 0.142 0 0.19 3.703 9.99+ 10 27 S1 0 0 0.238 0.008 0.317 9.99+9.99+ 11 28 S1 0 0 0.238 0.008 0.317 9.99+9.99+ 12 29 S1 0 0.013 0.238 0 0.317 9.99+9.99+ 13 30 S1 0 0.013 0.238 0 0.317 9.99+9.99+ 14 31 S1 0 0.001 0.142 0.009 0.19 9.99+9.99+ 15 32 S1 0 0.001 0.142 0.009 0.19 9.99+9.99+ 16 33 S1 0 0.014 0.142 0.001 0.19 9.99+9.99+ 17 34 S1 0 0.014 0.142 0.001 0.19 9.99+9.99+ Slab Sliding Safety Factors LC Slab Angle[deg] Va-xx[k] Vr-xx[k] Va-zz[k] Vr-zz[k] SR-xx SR-zz 1 18 S1 0 0 0.095 0 0.095 9.99+9.99+ 2 19 S1 0 0.011 0.095 0 0.095 8.778 9.99+ 3 20 S1 0 0.011 0.095 0 0.095 8.778 9.99+ 4 21 S1 0 0 0.095 0.018 0.095 9.99+5.267 5 22 S1 0 0 0.095 0.018 0.095 9.99+5.267 6 23 S1 0 0.011 0.057 0 0.057 5.267 9.99+ 7 24 S1 0 0.011 0.057 0 0.057 5.267 9.99+ 8 25 S1 0 0 0.057 0.018 0.057 9.99+3.16 9 26 S1 0 0 0.057 0.018 0.057 9.99+3.16 10 27 S1 0 0.004 0.095 0 0.095 9.99+9.99+ 11 28 S1 0 0.004 0.095 0 0.095 9.99+9.99+ 12 29 S1 0 0 0.095 0.004 0.095 9.99+9.99+ 13 30 S1 0 0 0.095 0.004 0.095 9.99+9.99+ 14 31 S1 0 0.004 0.056 0 0.056 9.99+9.99+ 15 32 S1 0 0.004 0.056 0 0.056 9.99+9.99+ 16 33 S1 0 0 0.056 0.004 0.056 9.99+9.99+ 17 34 S1 0 0 0.056 0.004 0.056 9.99+9.99+ RISAFoundation Version 15.0.1.29 Page 3 [P:\...\...\...\...\Structural\Calculations\100A-SW\100A-SW.fnd] 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 2.3 Anchorage Design Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | 100-SW Anchor Design Page: Specifier: E-Mail: Date: 1 10/25/2023 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 316 5/8 (3 1/4) hnom2 Item number: 2210306 KB-TZ2 5/8x6 SS316 Effective embedment depth: hef,act = 3.250 in., hnom = 3.750 in. Material: AISI 316 Evaluation Service Report: ESR-4266 Issued I Valid: 12/17/2021 | 12/1/2023 Proof: Design Method ACI 318-14 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plateR : lx x ly x t = 7.000 in. x 4.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 3000, fc' = 3,000 psi; h = 8.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: > No. 4 bar with stirrups Seismic loads (cat. C, D, E, or F) Tension load: yes (17.2.3.4.3 (d)) Shear load: yes (17.2.3.5.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [kip, ft.kip] 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | 100-SW Anchor Design Page: Specifier: E-Mail: Date: 2 10/25/2023 1.1 Design results Case Description Forces [kip] / Moments [ft.kip]Seismic Max. Util. Anchor [%] 1 Combination 1 N = -0.016; Vx = 0.015; Vy = 0.000; Mx = 0.00000; My = 0.02200; Mz = 0.00000; yes 2 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | 100-SW Anchor Design Page: Specifier: E-Mail: Date: 3 10/25/2023 2 Proof I Utilization (Governing Cases) Design values [kip] Utilization Loading Proof Load Capacity bN / b V [%]Status Tension Concrete Breakout Failure 0.044 3.285 2 / - OK Shear Concrete edge failure in direction x+ 0.015 3.530 - / 1 OK Loading bN bV z Utilization bN,V [%]Status Combined tension and shear loads 0.013 0.004 5/3 1 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | 100-SW Anchor Design Page: Specifier: E-Mail: Date: 4 10/25/2023 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 2.4 Equipment Drawing Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 Product data sheet Characteristics H363RB Safety switch, heavy duty, fusible, 100A, 3 poles, 100 hp, 600 VAC/DC, NEMA 3R, bolt-on hub, Product availability : Stock - Normally stocked in distribution facility Price* : 1,644.00 USD Main Product Single Throw Safety Switch Current Rating 100 A Number of Poles 3 Voltage Rating 600 V AC/DC Disconnect Type Fusible disconnect Short Circuit Current Rating 10 kA H or K 200 kA R, J or L Mounting Type Surface Factory Installed Neutral None Electrical Connection Lugs Duty Rating Heavy duty Certifications UL listed file E2875 Enclosure Rating NEMA 3R galvannealed steel Wire Size AWG 12...AWG 1/0 aluminium AWG 14...AWG 1/0 copper Complementary Maximum Horse Power Rating 25 hp 480 V AC 50...60 Hz 3 phase NEC 240.6 60 hp 480 V AC 50...60 Hz 3 phase NEC 430.52 30 hp 600 V AC 50...60 Hz 3 phase NEC 240.6 100 hp 600 V AC 50...60 Hz 3 phase NEC 430.52 50 hp 600 V DC Tightening torque 50 lbf.in (5.65 N.m) AWG 1...AWG 3/0) 45 lbf.in (5.08 N.m) AWG 6...AWG 4) 40 lbf.in (4.52 N.m) 0.01 in² (8.367 mm²) AWG 8) 35 lbf.in (3.95 N.m) 0.00…0.01 in² (2.06…5.261 mm²) AWG 14...AWG 10) Width 10.25 in (260.35 mm) Di s c l a i m e r : T h i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i ni n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s *  Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price. May 6, 2021 1 909 N Grand Ave - 101116238 & 201806132/15/2024 Height 21.25 in (539.75 mm) Depth 6.38 in (162.05 mm) Ordering and shipping details Category 00009 - H&HU SW,2&3P,N3R,30-200A Discount Schedule DE1 GTIN 00785901482666 Nbr. of units in pkg.1 Package weight(Lbs)17.46 lb(US) (7.92 kg) Returnability Yes Country of origin US Packing Units Unit Type of Package 1 PCE Package 1 Height 7.10 in (18.034 cm) Package 1 width 10.70 in (27.178 cm) Package 1 Length 23.30 in (59.182 cm) Unit Type of Package 2 PAL Number of Units in Package 2 1 Package 2 Weight 759.00 lb(US) (344.276 kg) Package 2 Height 43.50 in (110.49 cm) Package 2 width 40.00 in (101.6 cm) Package 2 Length 48.00 in (121.92 cm) Offer Sustainability Sustainable offer status Green Premium product California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov REACh Regulation REACh Declaration REACh free of SVHC Yes EU RoHS Directive Compliant EU RoHS Declaration Mercury free Yes RoHS exemption information Yes China RoHS Regulation China RoHS declaration Product out of China RoHS scope. Substance declaration for your information. Environmental Disclosure Product Environmental Profile PVC free Yes Contractual warranty Warranty 18 months 2 909 N Grand Ave - 101116238 & 201806132/15/2024 Product data sheet Dimensions Drawings H363RB Approximate Dimensions 3 909 N Grand Ave - 101116238 & 201806132/15/2024 Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 .0.0 3.0 400A-SW Foundation IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 3.1 Foundation Design Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 Structural Calculations Charge Ready Program Date: 10/27/2023 Calculated by: MM Checked By: DPB 400A SW - Structural Calculation _________________________________________________________________________ I. References 1. ASCE 7-16 2. Schneider Electric Single Throw Safety Switch, 400A, 600V II. Equipment Information weq 10.13in(Width of Equipment) leq 27.88in(Length of Equipment) h eq 50.31in(Height of Equipment) Weq 186lb(Weight of Equipment) h g 18in(Height above Ground; Assumed) n 2(Number of Posts) s 2ft(Spacing of Posts; Assumed) III. Equipment Loading Dead Load: SF 1.5(Safety Factor to Account for Misc Parts) DL Weq SF n 139.50 lb(Dead Load at Base of Post) Wind Load: V 95mph(Basic Wind Speed: Risk Category II) Exposure Category C k d 0.85(ASCE Table 26.6-1) k zt 1.0(ASCE 7-16 Section 26.8.1) k e 1.0(ASCE Table 26.9-1) k z 0.85(ASCE Table 26.10-1) Gf 0.85(ASCE Equation 26.10-1) Page: 1 of 4 909 N Grand Ave - 101116238 & 201806132/15/2024 Structural Calculations Charge Ready Program Date: 10/27/2023 Calculated by: MM Checked By: DPB Cf 1.4(ASCE Figure 29.4-1) (Design Wind Pressure)q z 0.00256 kzk ztkdkeV2 lb ft2 mph2   16.69 lb ft2 Wx Gf Cfqzweqh eq70.30 lb(Force due to Wind in X-Direction) Wz Gf Cfqzleqh eq193.49 lb(Force due to Wind in Z-Direction) Reactions due to Wind in X-Direction: Rx1 Wx n 35.15 lb(Shear Reaction at Base of Post) Fy1 Wx h g h eq 2  s n63.21 lb(Vertical Reaction at Base of Post; One Post in Compression; One in Uplift) Reactions due to Wind in Z-Direction: Rz1 Wz n 96.74 lb(Shear Reaction at Base of Post) Mx1 Wx n h g heq 2 126.41 lb ft(Moment Reaction at Base of Post) Seismic Load: SDS 1.034(Spectral Acceleration, short period, ASCE 7-16 Section 11.4.5) SD1 0.461(Spectral Acceleration,1s period, ASCE 7-16 Section 11.4.6) Ie 1.5(Importance Factor, ASCE 7-16 Section 13.1.3) ap 1.0(Amplification Factor, ASCE 7-16 Table 13.6-1) Rp 2.5(Response Modification Factor, ASCE 7-16 Table 13.6-1) Ω 2(Overstrength Factor, ASCE 7-16 Table 13.6-1) z 0 Page: 2 of 4 909 N Grand Ave - 101116238 & 201806132/15/2024 Structural Calculations Charge Ready Program Date: 10/27/2023 Calculated by: MM Checked By: DPB h 1 Fp 0.4 apSDS Rp Ie   1 2 z h 0.25(ASCE 7-16 Equation 13.3-1) Fp.min 0.3 SDSIe0.47(ASCE 7-16 Equation 13.3-2) (ASCE 7-16 Equation 13.3-3)Fp.max 1.6 SDSIe2.48 Fp min max Fp Fp.min Fp.max 0.47 Fv 0.2 SDS0.21 Eh Fp DL65 lb(Horizontal Seismic Force, ASCE 7-16 Section 13.3.1.1) Ev Fv DL29 lb(Vertical Seismic Force, ASCE 7-16 Section 13.3.1.2) Reactions due to Seismic in X-Direction: Rx2 Eh n 32.45 lb(Shear Reaction at Base of Post) Fy2 Eh hg heq 2  s n58.36 lb(Vertical Reaction at Base of Post; One Post in Compression; One in Uplift) Reactions due to Seismic in Z-Direction: Rz2 Eh n 32.45 lb(Shear Reaction at Base of Post) Mx2 Eh n h g h eq 2 116.72 lb ft(Moment Reaction at Base of Post) Reactions due to Seismic in Y-Direction: Fv Ev n 14.42 lb(Vertical Reaction at Base of Post due to Vertical Seismic Force) IV. Post Design Mu.max max M x1 M x2 126.41 lb ft Page: 3 of 4 909 N Grand Ave - 101116238 & 201806132/15/2024 Structural Calculations Charge Ready Program Date: 10/27/2023 Calculated by: MM Checked By: DPB Sx 0.571in3(Section Modulus; Per Unistrut Manual) σ 3300 lb in2(Yield Stress of Unistrut) Mn σ Sx157.02 lb ft ϕ 0.9 (Moment Capacity of Unistrut)ϕMn ϕ Mn 141.32 lb ft Check if ϕMn Mu.max"OK""No Good" "OK" V. Anchor Design Note: Anchor Design is performed in Hilti Profis. Seismic loads are multiplied by the overload factor. The anchors passes all checks. Vi. Foundation Design Note: Foundation Design is performed in RISA Foundation. The foundation passed all checks. Page: 4 of 4 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 3.2 RISA Foundation Output Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 Company : NV5 Nov 3, 2023 9:24 AMDesigner : MM Job Number : Charge Ready Program Checked By:_____ Model Name : Pad Foundation Point Coordinates Label Z [ft] X [ft] 1 N1 0 0 2 N2 2 0 3 N3 2 3.5 4 N4 0 3.5 5 N5 1 0.75 6 N6 1 2.75 7 N7 1 1.75 8 N8 1 3.5 9 N9 0 1.75 10 N10 1 0 11 N11 2 1.75 Load Combinations Label Solve Servi...AB...SF Ca...Fa...CategoryFa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa...Ca...Fa... 1 1.4D Yes DL 1.4 2 1.2DL+1.0WL(...Yes DL 1.2 WLX 1 3 1.2DL+1.0WL(...Yes DL 1.2 WLX -1 4 1.2DL+1.0WL(...Yes DL 1.2 WLZ 1 5 1.2DL+1.0WL(...Yes DL 1.2 WLZ -1 6 0.9DL+1.0WL(...Yes DL 0.9 WLX 1 7 0.9DL+1.0WL(...Yes DL 0.9 WLX -1 8 0.9DL+1.0WL(...Yes DL 0.9 WLZ 1 9 0.9DL+1.0WL(...Yes DL 0.9 WLZ -1 10 1.2DL+1.0ELY...Yes DL 1.2 ELY 1 ELX 1 11 1.2DL+1.0ELY...Yes DL 1.2 ELY 1 ELX -1 12 1.2DL+1.0ELY...Yes DL 1.2 ELY 1 ELZ 1 13 1.2DL+1.0ELY...Yes DL 1.2 ELY 1 ELZ -1 14 0.9DL-1.0ELY...Yes DL 0.9 ELY -1 ELX 1 15 0.9DL-1.0ELY...Yes DL 0.9 ELY -1 ELX -1 16 0.9DL-1.0ELY...Yes DL 0.9 ELY -1 ELZ 1 17 0.9DL-1.0ELY...Yes DL 0.9 ELY -1 ELZ -1 18 1.0DL Yes Yes DL 1 19 1.0DL+0.6WL(...Yes Yes DL 1 WLX 0.6 20 1.0DL+0.6WL(...Yes Yes DL 1 WLX -0.6 21 1.0DL+0.6WL(...Yes Yes DL 1 WLZ 0.6 22 1.0DL+0.6WL(...Yes Yes DL 1 WLZ -0.6 23 0.6DL+0.6WL(...Yes Yes DL 0.6 WLX 0.6 24 0.6DL+0.6WL(...Yes Yes DL 0.6 WLX -0.6 25 0.6DL+0.6WL(...Yes Yes DL 0.6 WLZ 0.6 26 0.6DL+0.6WL(...Yes Yes DL 0.6 WLZ -0.6 27 1.0DL+0.7ELY...Yes Yes DL 1 ELY 0.7 ELX 0.7 28 1.0DL+0.7ELY...Yes Yes DL 1 ELY 0.7 ELX -0.7 29 1.0DL+0.6ELY...Yes Yes DL 1 ELY 0.7 ELZ 0.7 30 1.0DL+0.7ELY...Yes Yes DL 1 ELY 0.7 ELZ -0.7 31 0.6DL-0.7ELY...Yes Yes DL 0.6 ELY -0.7 ELX 0.7 32 0.6DL-0.7ELY...Yes Yes DL 0.6 ELY -0.7 ELX -0.7 33 0.6DL-0.7ELY...Yes Yes DL 0.6 ELY -0.7 ELZ 0.7 34 0.6DL-0.7ELY...Yes Yes DL 0.6 ELY -0.7 ELZ -0.7 Point Loads and Moments (Cat 1 : DL) Label Direction Magnitude[k,k-ft] 1 N6 Y 0.14 2 N5 Y 0.14 Point Loads and Moments (Cat 16 : ELX) Label Direction Magnitude[k,k-ft] 1 N5 X 0.032 RISAFoundation Version 15.0.1.29 Page 1 [P:\...\...\...\...\Structural\Calculations\400A-SW\400A-SW.fnd] 909 N Grand Ave - 101116238 & 201806132/15/2024 Company : NV5 Nov 3, 2023 9:24 AMDesigner : MM Job Number : Charge Ready Program Checked By:_____ Model Name : Pad Foundation Point Loads and Moments (Cat 16 : ELX) (Continued) Label Direction Magnitude[k,k-ft] 2 N6 X 0.032 3 N5 Y -0.058 4 N6 Y 0.058 Point Loads and Moments (Cat 17 : ELY) Label Direction Magnitude[k,k-ft] 1 N5 Y 0.014 2 N6 Y 0.014 Point Loads and Moments (Cat 18 : ELZ) Label Direction Magnitude[k,k-ft] 1 N5 Z 0.032 2 N6 Z 0.032 3 N5 MX 0.117 4 N6 MX 0.117 Point Loads and Moments (Cat 19 : WLX) Label Direction Magnitude[k,k-ft] 1 N6 X 0.035 2 N5 X 0.035 3 N5 Y -0.063 4 N6 Y 0.063 Point Loads and Moments (Cat 21 : WLZ) Label Direction Magnitude[k,k-ft] 1 N5 Z 0.097 2 N6 Z 0.097 3 N5 MX 0.126 4 N6 MX 0.126 Soil Definitions Label Subgrade Modulus[k/ft^3] Allowable Bearing[ksf] Depth Properties Default? 1 Default 100 1 None Yes Concrete Properties Label E [ksi] G [ksi] Nu Therm (/1E...Density[k/ft... f'c[ksi] Lambda Flex Steel[...Shear Stee... 1 Conc3000NW 3156 1372 0.15 0.6 0.145 3 1 60 60 2 Conc3500NW 3409 1482 0.15 0.6 0.145 3.5 1 60 60 3 Conc4000NW 3644 1584 0.15 0.6 0.145 4 1 60 60 4 Conc3000LW 2085 907 0.15 0.6 0.11 3 0.75 60 60 5 Conc3500LW 2252 979 0.15 0.6 0.11 3.5 0.75 60 60 6 Conc4000LW 2408 1047 0.15 0.6 0.11 4 0.75 60 60 Slabs Label Thickness [in] Material Local Axis Angle...Analysis Offset [i...Passive Pressur...Soil Overburden ...Icr Factor 1 S1 8 Conc3000NW 0 0 0 0 0.25 Slab Rebar Parameters Label Top ... Bottom...Max Top B...Min Top Ba...Max Bot Ba...Min Bot Bar S... Spacing Incre... Side Cover[in] Rebar Options 1 Typical N/A #5 N/A N/A 12 12 3 3 Mid-Depth Only RISAFoundation Version 15.0.1.29 Page 2 [P:\...\...\...\...\Structural\Calculations\400A-SW\400A-SW.fnd] 909 N Grand Ave - 101116238 & 201806132/15/2024 Company : NV5 Nov 3, 2023 9:24 AMDesigner : MM Job Number : Charge Ready Program Checked By:_____ Model Name : Pad Foundation Design Strips Label Rebar Angle from P... No. of Design Cuts Design Rule 1 DS1 0 50 Typical 2 DS2 90 50 Typical Envelope Slab Soil Pressures Label Max UC Max LC Soil Pressure[ksf] Allowable Bearing[ksf] Point 1 S1 0.186 30 0.186 1 N1 Strip Reinforcing Label UC Top LC Top Bars Governin... UC Bot LC Bot Bars/...Governin... UC Shear LC Governin... 1 DS1 0.003 9 0.01 5 #5@12in DS1-X25 0.015 5 DS1-X25 2 DS2 0.002 1 0 N/A #5@12in NA 0.002 1 DS2-X25 Slab Overturning Safety Factors LC Slab Angle[deg] Mo-xx[k-ft] Ms-xx[k-ft] Mo-zz[k-ft] Ms-zz[k-ft] Ms-xx/Mo-xx Ms-zz/Mo-zz 1 18 S1 0 0 0.957 0 1.674 9.99+9.99+ 2 19 S1 0 0 0.957 0.104 1.674 9.99+9.99+ 3 20 S1 0 0 0.957 0.104 1.674 9.99+9.99+ 4 21 S1 0 0.229 0.957 0 1.674 4.181 9.99+ 5 22 S1 0 0.229 0.957 0 1.674 4.181 9.99+ 6 23 S1 0 0 0.574 0.104 1.004 9.99+9.696 7 24 S1 0 0 0.574 0.104 1.004 9.99+9.696 8 25 S1 0 0.229 0.574 0 1.004 2.509 9.99+ 9 26 S1 0 0.229 0.574 0 1.004 2.509 9.99+ 10 27 S1 0 0 0.976 0.111 1.708 9.99+9.99+ 11 28 S1 0 0 0.976 0.111 1.708 9.99+9.99+ 12 29 S1 0 0.194 0.976 0 1.708 5.041 9.99+ 13 30 S1 0 0.194 0.976 0 1.708 5.041 9.99+ 14 31 S1 0 0.02 0.574 0.145 1.004 9.99+6.91 15 32 S1 0 0.02 0.574 0.145 1.004 9.99+6.91 16 33 S1 0 0.213 0.574 0.034 1.004 2.691 9.99+ 17 34 S1 0 0.213 0.574 0.034 1.004 2.691 9.99+ Slab Sliding Safety Factors LC Slab Angle[deg] Va-xx[k] Vr-xx[k] Va-zz[k] Vr-zz[k] SR-xx SR-zz 1 18 S1 0 0 0.287 0 0.287 9.99+9.99+ 2 19 S1 0 0.042 0.287 0 0.287 6.833 9.99+ 3 20 S1 0 0.042 0.287 0 0.287 6.833 9.99+ 4 21 S1 0 0 0.287 0.116 0.287 9.99+2.466 5 22 S1 0 0 0.287 0.116 0.287 9.99+2.466 6 23 S1 0 0.042 0.172 0 0.172 4.1 9.99+ 7 24 S1 0 0.042 0.172 0 0.172 4.1 9.99+ 8 25 S1 0 0 0.172 0.116 0.172 9.99+1.479 9 26 S1 0 0 0.172 0.116 0.172 9.99+1.479 10 27 S1 0 0.045 0.293 0 0.293 6.537 9.99+ 11 28 S1 0 0.045 0.293 0 0.293 6.537 9.99+ 12 29 S1 0 0 0.293 0.045 0.293 9.99+6.537 13 30 S1 0 0 0.293 0.045 0.293 9.99+6.537 14 31 S1 0 0.045 0.166 0 0.166 3.713 9.99+ 15 32 S1 0 0.045 0.166 0 0.166 3.713 9.99+ 16 33 S1 0 0 0.166 0.045 0.166 9.99+3.713 17 34 S1 0 0 0.166 0.045 0.166 9.99+3.713 RISAFoundation Version 15.0.1.29 Page 3 [P:\...\...\...\...\Structural\Calculations\400A-SW\400A-SW.fnd] 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 3.3 Anchorage Design Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | 400-SW Anchor Design Page: Specifier: E-Mail: Date: 1 10/25/2023 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 316 5/8 (3 1/4) hnom2 Item number: 2210306 KB-TZ2 5/8x6 SS316 Effective embedment depth: hef,act = 3.250 in., hnom = 3.750 in. Material: AISI 316 Evaluation Service Report: ESR-4266 Issued I Valid: 12/17/2021 | 12/1/2023 Proof: Design Method ACI 318-14 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plateR : lx x ly x t = 7.000 in. x 7.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 3000, fc' = 3,000 psi; h = 8.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: > No. 4 bar with stirrups Seismic loads (cat. C, D, E, or F) Tension load: yes (17.2.3.4.3 (d)) Shear load: yes (17.2.3.5.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [kip, ft.kip] 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | 400-SW Anchor Design Page: Specifier: E-Mail: Date: 2 10/25/2023 1.1 Design results Case Description Forces [kip] / Moments [ft.kip]Seismic Max. Util. Anchor [%] 1 Combination 1 N = -0.168; Vx = 0.970; Vy = 0.000; Mx = 0.00000; My = 0.12600; Mz = 0.00000; yes 21 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | 400-SW Anchor Design Page: Specifier: E-Mail: Date: 3 10/25/2023 2 Proof I Utilization (Governing Cases) Design values [kip] Utilization Loading Proof Load Capacity bN / b V [%]Status Tension Concrete Breakout Failure 0.214 4.633 5 / - OK Shear Concrete edge failure in direction x+ 0.970 4.706 - / 21 OK Loading bN bV z Utilization bN,V [%]Status Combined tension and shear loads 0.046 0.206 5/3 8 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 909 N Grand Ave - 101116238 & 201806132/15/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | 400-SW Anchor Design Page: Specifier: E-Mail: Date: 4 10/25/2023 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 3.4 Equipment Drawing Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024 Product data sheet Characteristics H365NR SWITCH FUSIBLE HD 600V 400A 3P NEUTRAL Product availability : Stock - Normally stocked in distribution facility Price** : 5,765.00 USD Main Product Single Throw Safety Switch Current Rating 400 A Certifications UL listed file E2875 Enclosure Rating NEMA 3R galvannealed steel Factory Installed Neutral Neutral (factory installed) Disconnect Type Fusible disconnect Short Circuit Current Rating 10 kA H or K 200 kA R, J or L Mounting Type Surface Number of Poles 3 Electrical Connection Lugs Duty Rating Heavy duty Voltage Rating 600 V AC/DC Wire Size AWG 1/0...750 kcmil copper or aluminium Complementary Width 708.15 mm (27.88 in) Height 1277.87 mm (50.31 in) Depth 257.30 mm (10.13 in) Tightening torque 62.14 N.m (550 lbf.in) AWG 1/0...750 kcmil) Ordering and shipping details Category 00054 - H&HU SW,NEMA3R,400-1200A Discount Schedule DE1 GTIN 00785901026686 Package weight(Lbs)84.37 kg (186 lb(US)) Returnability Yes Di s c l a i m e r : T h i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i ni n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s Feb 5, 2020 1 909 N Grand Ave - 101116238 & 201806132/15/2024 Country of origin MX Offer Sustainability Sustainable offer status Green Premium product California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov REACh Regulation REACh Declaration REACh free of SVHC Yes EU RoHS Directive Compliant EU RoHS Declaration Mercury free Yes RoHS exemption information Yes China RoHS Regulation China RoHS declaration Product out of China RoHS scope. Substance declaration for your information. Environmental Disclosure Product Environmental Profile Circularity Profile No need of specific recycling operations Contractual warranty Warranty 18 months 2 909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 4.0 Wind Design Parameters Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024                              !""#        $%&'()*+,-.'/&01., 233'%445 67689 :; ;6" 7<;= >..'31,&0%45 ?? @?<AB;!<< B@<@CAB DE%F&01.,5 <A  G1/%40&/H5 "7"?!<7!<7<?I<@IA6<CCJ K&L&'3*GMH%5 N 2$>D*OPQR STU<7!V CCW STU"@!V <W STU@7!V W STU<77!V B<W T X U B6W T X UU 6@W T X UUU <7"W T X UY <7CW 2$>D*OPQZ STU<7!V "W STU"@!V 6W STU@7!V B@W STU<77!V 6<W T X U <77W T X UU <<7W T X UUU!UY <<@W 2$>D*OPZ[  !7@NB@W \]^_`^abcda_efgehid^g_]^`^_jk_lk\_`^mc^hd_ifn_adid^_o`_cohic_ip^fgp^fda_do_d]^_qicb^a_o`_ifn_g^cef^ideof_cef^a_pig^_gb`efr_d]^_sbecgefr_hog^_igotdeof_t`oh^aau_va^`a_a]obcg_hofme`p_ifn obdtbd_osdief^g_m`op_d]ea_dooc_wed]_d]^_cohic_xbd]o`edn_yiqefr_zb`eagehdeof_s^mo`^_t`oh^^gefr_wed]_g^aerfu {c^ia^_fod^_d]id_d]^_x\|_yi}i`ga_sn_~ohideof_w^saed^_wecc_fod_s^_btgid^g_do_abtto`d_x|€_ ‚ƒƒu_„efg_obd_w]nu …14(E&1/%'         W  :        X   ;                           † W;   ‡             ; :   X X 8ˆI # ‰  !   X   ;   X  W   :  XW           !   X  S     ;X X;  W  ;  X  ‡W      Š‹Œ Ž ‘’“”‘•‘“–—˜—™“š››œšžŸ“ ¡¢š £ž’›¤•“‘“¥‘’“ž¤¤›¤ 909 N Grand Ave - 101116238 & 201806132/15/2024                                                                                                                                                    !       909 N Grand Ave - 101116238 & 201806132/15/2024 .0.0 5.0 Seismic Design Parameters Tom's Truck Center #2 CLIENT: Charge Ready Program NV5 Project Number: 0000690_F8 IFC Design https://nv5inc-my.sharepoint.com/personal/dieter_bahr_nv5_com/Documents/Desktop/Project Folders/Charge Ready Fdns/Final Calculations/Calculations/Tom's Trucks Cover Sheet.xlsm 909 N Grand Ave - 101116238 & 201806132/15/2024                                    !"##$      %&'()*+,-.(/'01.,233(&445 67689 : ; ;6#!7<;=>..(31,'0&45 ??!@?<AB;"<<!B@<@CABDE&F'01.,5 <A! G1/&40'/H5 #7#?"<7"#@<BIA6I<<?AAJK'L'(3GMH&5  NO&-&(&,)&P.)Q/&,05  !"<CO14R>'0&S.(M5 TT%10&>E'445 U>DOK.(1L.,0'EO&4H.,4&%H&)0(Q/ P&41S,K.(1L.,0'EO&4H.,4&%H&)0(Q/V'41)W'('/&0&(4X'/& Y'EQ& P&4)(1H01.,<#6# Z [\ N  ]  ^7#_<7AC< Z [\ N  ]  ^<7_Z<@@  "N        :  Z<7C6<  "N        :  `<7?A 8N  N \:   7#`<7AC< 8N  N \:   <7a233101.,'E+,-.(/'01.,X'/& Y'EQ& P&4)(1H01.,` `  N \ \ $<#  N     7#$:<@  N     <7[76??      ]7#_[<76#!      ]<7_9 7@A# Z 9 \    $9<#  N     99Z 7C@<  N   \    B  \"       ]_[ <#6#     "  \ \ N  ]7#_= <?BA $  N"       ]#b     c  @7  _` <@ $  N    :  ]7#_<[ 7AC<     "  \ \ N  ]<7_<= 7A6! $  N"       ]#b     c  @7  _<` 7C $  N    :  ]<7_ defghijkljmjnopoqrsstuvwxyzrx{vks|mj}jkv||s| 7 # A C B W&(1.3~47777#77A77C77B7<77<#7<A7%'~S7 # A C B W&(1.3~47777#77A77C77B7<77%'~S 909 N Grand Ave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rand Ave - 101116238 & 201806132/15/2024 TI T L E S H E E T LOCATION MAP GENERAL GRADING AND DRAINAGE NOTES: GENERAL CONTRACT NOTES: G0 0 PROJECT INFORMATION: SURVEY NOTE: · UTILITY NOTE: INDEX SHEET: DESIGN CRITERIA: SCOPE OF EV IMPROVEMENT WORK: LIST OF CONSULTANTS: OWNER/ REPRESENTATIVE INFORMATION: FLOOD ZONE NOTES: CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON CONCRETE NOTES:N CRT-2021-0112 | TOM'S TRUCK CENTER #2 DIGALERT NOTES SH E E T DA T E 05 / 1 6 / 2 0 2 3 CH A R G E R E A D Y P R O G A M TO M ' S T R U C K C E N T E R # 2 C R T - 2 0 2 1 - 0 1 1 2 Bldg# 101116238 Elec# 20180613 APPROVALS: PLNG - FArias BLDG - JLo ELEC - MSmith 909 N Grand Ave - 101116238 & 201806132/15/2024 I-5 F W Y E SANTA ANA BLVD N G R A N D A V E E FRUIT ST PLAN VIEW: OVERALL SITE PLAN OV E R A L L S I T E P L A N G0 1 SH E E T DA T E 05 / 1 6 / 2 0 2 3 CH A R G E R E A D Y P R O G A M TO M ' S T R U C K C E N T E R # 2 C R T - 2 0 2 1 - 0 1 1 2 N 909 N Grand Ave - 101116238 & 201806132/15/2024 E E E E E E E E E E X X OE OE OE OE OE OE OE OE OE OE OE OE EEEEE E E NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G INSTALL BOLLARD WITH FOUNDATION PER DETAIL 1, THIS SHEET, 5 EA, TYP. SCE OWNED BOLLARDS, 6 EA, TYP. INSTALL CONCRETE PAD PER DETAIL 1 ON C01. SEE E01 FOR ADDITIONAL DETAIL INSTALL CONCRETE PAD PER DETAIL 2 ON C01 (TYP). SEE E02 FOR ADDITIONAL DETAIL INSTALL CONCRETE PAD PER DETAIL 3 ON C01. SEE E02 FOR ADDITIONAL DETAIL INSTALL CONCRETE PAD PER DETAIL 3 ON C01. SEE E02 FOR ADDITIONAL DETAIL PLAN VIEW: CIVIL SITE LAYOUT C0 0 LINE LEGEND EXISTIING NATURAL GAS GEOPHYSICAL LINE EXISTING ELECTRIC LINE EXISTING EDGE OF PAVEMENT LINE EXISTIING TELECOM LINE PROPOSED ELECTRICAL CONDUIT EXISTIING WATER LINE 1.FOR ELECTRICAL INFORMATION, SEE SHEET E00 GENERAL NOTES: 1.CONTRACTOR SHALL LEGALLY DISPOSE OF ALL DEMOLISHED MATERIALS OFF SITE. 2.CONTRACTOR SHALL PROTECT ALL EXITING UTILITY IMPROVEMENTS NOT SPECIFICALLY DESIGNATED FOR REMOVAL. 3.THE ON-SITE UNDERGROUND UTILITIES SHOWN ON THIS SHEET ARE AT AN APPROXIMATE LOCATION. THE EXTENT, LOCATIONS AND SIZES ARE UNKNOWN. THE CONTRACTOR SHALL POTHOLE TO LOCATE AND VERIFY THE UNDERGROUND UTILITY LINES PRIOR TO REMOVAL. 4.CONTRACTOR TO PROTECT AND PRESERVE IN PLACE ANY FOUND SURVEY MONUMENTS. ANY MONUMENTS DISTURBED SHALL BE RESET BY A LICENSED SURVEYOR AND THE APPROPRIATE PAPERWORK FILLED WITH THE CITY OR COUNTY. 5.ALL HAZARDOUS MATERIALS ENCOUNTERED DURING SITE DEMOLITION SHALL BE REMEDIATED AND DISPOSED OF PER STATE AND EPA REQUIREMENTS. 6.CONTRACTOR SHALL CONTACT AND COORDINATE WITH ALL UTILITY AGENCIES PRIOR TO THE START OF ANY DEMOLITION OR CONSTRUCTION. 7.ANY EXISTING UTILITIES AND/ OR IMPROVEMENTS THAT BECOME DAMAGED DURING CONSTRUCTION SHALL BE COMPLETELY RESTORED TO THE SATISFACTION OF THE OWNER AND AGENCY HAVING JURISDICTION, AT THE CONTRACTOR'S SOLE EXPENSE. DEMOLITION NOTES: PROPOSED ELECTRICAL CONDUIT (BY SCE) EXISTING FENCE LINE LIMITS OF WORK SCALE: BOLLARD WITH FOUNDATION1 C00 NONE NOTES: 48 " 24" 1.CAUTION MUST BE TAKEN WHEN EXCAVATING TO NOT DISTURB EXISTING UNDERGROUND UTILITIES. 2.CONCRETE SHALL BE 3250 PSI MINIMUM AT 28 DAYS 3.USE 4 INCH PLAIN STEEL PIPE, WITH A MINIMUM WALL THICKNESS OF 0.185 INCHES. THE PIPE SHALL BE PRIMED WITH AN OIL-BASED PRIMER AND PAINTED YELLOW. FILL PIPE WITH CONCRETE EXISTING OR PROPOSED PAVEMENT YELLOW REFLECTIVE TAPE, 2" WIDE 6" YELLOW PLASTIC WARNING TAPE TO BE REQUIRED ABOVE AND ALONG ENTIRE LENGTH OF DUCT BANK. 24 " M I N . T O T H E T O P OF H I G H E S T C O N D U I T SEE ELECTRICAL PLANS FOR CONDUIT SIZE, TYPE, AND WIRING 12 " 3" 2" REPLACE TOP SURFACE IN KIND, MATCH EXISTING PAVEMENT DEPTH IN PAVED AREAS AND RECOMPACT SOIL TO 90% IN UNPAVED AREAS (MINIMUM 6" CONCRETE SURFACE) 18" 36" 3" SCALE: TRENCH AND PAVEMENT RESURFACING2 C00 NONE SLOPE FOOTING AWAY FROM PIPE AT 2% MIN SLOPE 48 " 95% COMPACTED NATIVE BACKFILL SH E E T DA T E 05 / 1 6 / 2 0 2 3 CH A R G E R E A D Y P R O G A M TO M ' S T R U C K C E N T E R # 2 C R T - 2 0 2 1 - 0 1 1 2 N 909 N Grand Ave - 101116238 & 201806132/15/2024 EE E E E E E E E E X OE OE OE OE OE OE OE OE OE OE OE OE EEEEEE E E C7 BTC POWER CABINET #2 BTC POWER CABINET #1 400A DS-SW-2 400A DS-SW-1 SCE XFMREV-SWBD-1 EV-XFMR EV-SWBD-2 C1C3C2 C2,C3 C6 C5 C4 NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G 100A DS-SW-3 C8 100A DS-SW-4 100A DS-SW-5 100A DS-SW-6 FREE WIRE CHG #2 C9 C12 C13 FREE WIRE CHG #3 C14 FREE WIRE CHG #4 C15 C10 C11 E0 0 EL E C T R I C A L S I T E L A Y O U T SCALE: CONDUIT SCHEDULE1 E00 NONE LINE LEGEND EXISTING NATURAL GAS GEOPHYSICAL LINE EXISTING FENCE LINE EXISTING ELECTRIC LINE EXISTING EDGE OF PAVEMENT LINE EXISTING TELECOM LINE PROPOSED ELECTRICAL CONDUIT EXISTING WATER LINE PROPOSED ELECTRICAL CONDUIT (BY SCE) 1.ALL ELECTRICAL POWER IN CLOSE PROXIMITY TO THE INSTALLATION OF THE ELECTRICAL VEHICLE STATION EQUIPMENT MUST BE POWERED OFF PRIOR TO THE START OF CONSTRUCTION, TO PREVENT ANY ELECTRICAL INJURIES. 2.SEE CONDUIT SCHEDULE FOR WIRE AND CONDUIT SIZE. 3.THE METHODS CONTAINED IN CEC/NEC ARTICLE 250 SHALL BE FOLLOWED TO COMPLY WITH GROUNDING AND BONDING OF ELECTRICAL SYSTEMS AND NON-CURRENT CARRYING CONDUCTIVE MATERIALS, ENCLOSURES, OR ITEMS FORMING PART OF ANY SUCH EQUIPMENT THAT ENCLOSES OR CARRIES ELECTRICAL CONDUCTOR OR EQUIPMENT THAT IS LIKELY TO BECOME ENERGIZED. SEE CEC/NEC 250.4(A)(1) THROUGH (5) FOR FURTHER DESCRIPTION, 4.WHERE TWO OR MORE GROUND RODS ARE TO BE INSTALLED, THE MINIMUM SEPARATION SHALL BE 6' PER CEC/NEC 250.53 (A)(2), AND (3) RESISTANCE OF ELECTRODES. 5.ALL CONDUITS SHALL COMPLY WITH CEC/NEC TABLE 300.5 MINIMUM BURIAL DEPTH, AND BE INSTALLED A MINIMUM OF 30" BELOW GRADE. 6.PER CEC/NEC 110.26 ”ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF SUCH EQUIPMENT.” 7.CHARGING STATION INSTALLATION IS OUTSIDE THE SCOPE OF THIS DOCUMENT. THIS ENGINEERING DESIGN CALLS FOR A WIRELESS COMMUNICATION SYSTEM IN PLACE OF AN ETHERNET CONNECTION TO EACH CHARGING STATION. THIS MUST BE FIELD VERIFIED AND CONFIRMED BY SCE PRIOR TO INSTALLATION. 8.ALL AC CONDUCTORS TO BE TYPE THWN-2 OR THHN. KEYED NOTES: 1.INSTALL NEW RACK MOUNTED DISCONNECT SWITCH. THE DESIGN AND INSTALLATION OF BTC POWER CABINETS AND EV CHARGING STATIONS ARE OUTSIDE THE SCOPE OF THIS PROJECT. SEE DETAIL 2 ON SHEET E02 FOR PAD DETAILS. 2.INSTALL NEW RACK MOUNTED DISCONNECT SWITCH. THE DESIGN AND INSTALLATION OF THE FREEWIRE BOOST CHARGER ARE OUTSIDE THE SCOPE OF THIS PROJECT. SEE DETAIL 1 ON SHEET E02 FOR PAD DETAILS. 3.STUB UP AND CAP CONDUIT FOR CHARGER POWER. COORDINATE LOCATION WITH CHARGER INSTALLER. 4.STUB UP AND CAP FOUR 3/4" CONDUITS TO LOCATION OF CUSTOMER TRENCHING FOR DISPENSER AUXILIARY POWER, COORDINATE LOCATION WITH DISPENSER INSTALLER. GENERAL NOTES: X EXISTING SEWER LINE EXISTING OVERHEAD ELECTRICAL LINE SH E E T DA T E 05 / 1 6 / 2 0 2 3 CH A R G E R E A D Y P R O G A M TO M ' S T R U C K C E N T E R # 2 C R T - 2 0 2 1 - 0 1 1 2 2 2 2 2 1 1 0 GRAPHIC SCALE: 1/8"=1'-0" 122468 16 FT. CONDUIT NUMBER FROM TO LENGTH (FT)CABLE CONDUIT SIZE (IN) CONDUIT TYPE COMMENTS C1 XFMR BY SCE BY SCE BY SCE BY SCE BY SCE UTILITY SERVICE C2 EV-SWBD-1 30 (3) 500 KCMIL, (1) #2 WIRE 3"PVC SCH. 40 BTC CHARGER POWER C3 400A DISCONNECT SW-1 15 NONE 3"PVC SCH. 40 C4 EV-SWBD-1 400A DISCONNECT SW-2 40 (3) 500 KCMIL, (1) #2 WIRE 3"PVC SCH. 40 C5 400A DISCONNECT SW-2 BTC#2 15 3"PVC SCH. 40 C6 EV-SWBD-1 EV-XFMR 25 3"PVC SCH. 40 C7 EV-XFMR EV-SWBD-2 25 2 - (4) 250 KCMIL, (1) #1/0 WIRE 3"PVC SCH. 40 C8 EV-SWBD-2 125 PVC SCH. 40 C9 115 PVC SCH. 40 C10 130 PVC SCH. 40 C11 100A DISCONNECT SW-6 150 C12 100A DISCONNECT SW-3 18 1.5"CONDUIT STUB-UP FOR CHARGER EQUIPMENT C13 20 1.5" C14 1.5" C15 FREE WIRE#4 NONE 1.5" EV-SWBD-2 EV-SWBD-2 EV-SWBD-2 100A DISCONNECT SW-4 100A DISCONNECT SW-5 100A DISCONNECT SW-6 FREE WIRE#3 FREE WIRE#2 FREE WIRE#1 100A DISCONNECT SW-5 100A DISCONNECT SW-4 100A DISCONNECT SW-3 400A DISCONNECT SW-1 BTC#1 EV-SWBD-1 NONE NONE NONE (3) #2, (1) #8 WIRE (3) #2, (1) #8 WIRE (3) #2, (1) #8 WIRE (3) #2, (1) #8 WIRE (3) 250 KCMIL, (1) #2 WIRE NONE PVC SCH. 40 480V POWER 208/120V POWER FREE WIRE CHARGER POWER PVC SCH. 40 PVC SCH. 40 PVC SCH. 40 PVC SCH. 40 1.5" 1.5" 1.5" 1.5" C16 BTC#1 DISPENSER A 20 NONEEV-SWBD-2 PVC SCH. 40 C17 20 NONEEV-SWBD-2 PVC SCH. 40 C18 20 NONEEV-SWBD-2 PVC SCH. 40 C19 20 NONEEV-SWBD-2 PVC SCH. 40 4 C8-C11 3 3 3 3 3/4" BTC#1 DISPENSER B BTC#2 DISPENSER A BTC#2 DISPENSER B 3/4" 3/4" 3/4" BTC CHARGER POWER FREE WIRE CHARGER POWER FREE WIRE CHARGER POWER FREE WIRE CHARGER POWER CONDUIT STUB-UP FOR CHARGER EQUIPMENT CONDUIT STUB-UP FOR CHARGER EQUIPMENT CONDUIT STUB-UP FOR CHARGER EQUIPMENT CONDUIT STUB-UP FOR CHARGER EQUIPMENT CONDUIT STUB-UP FOR CHARGER EQUIPMENT CONDUIT STUB-UP FOR CHARGER EQUIPMENT CONDUIT STUB-UP FOR CHARGER EQUIPMENT 3 3 CONDUIT STUB-UP FOR CHARGER EQUIPMENT CONDUIT STUB-UP FOR CHARGER EQUIPMENT FREE WIRE CHG #1 20 20 6/30/20256-30-2025 909 N Grand Ave - 101116238 & 201806132/15/2024 7' - 3 12" 6" 1' - 0 " PLAN VIEW 2 9'-73 4" 6"2'-8"113 4"5'-0"6" C8-C11, 1.5" PVC TO 100A DS-SW-3 TO DS-SW-6 9 10 11 C7A & C7B, 3" PVC A A 1 11 10 9 16 15 14 C16-C19, 3/4" PVC TO DISPENSER 1A, 1B, 2A, 2B 1'-8"1'-8"2'-10"3'-6" C1 BY SCE C6, 3" PVC 10119 14 2' - 5 12" 2' - 1 0 " 6" B B 16 15 14 5 SECTION A-A 6' - 6 " 23 2 3 MCB 500A 4 21 21 31 33 23 14 3' - 8 12" 1 C8-C11, 1.5" PVC TO 100A DS-SW-3 TO DS-SW-6 C16-C19, 3/4" PVC TO DISPENSER 1A, 1B, 2A, 2B 2922 22 20 26 C6, 3" PVC TO EV-SWBD-2 25 2414 TO GROUND RODS C2,C4, 3" PVC TO 400A DS-SW-1 TO DS-SW-2 37 2425 3234 35 36 12 22 22 12 E0 1 A EL E C T R I C A L D E T A I L S SH E E T DA T E 05 / 1 6 / 2 0 2 3 CH A R G E R E A D Y P R O G A M TO M ' S T R U C K C E N T E R # 2 C R T - 2 0 2 1 - 0 1 1 2 SCALE: ELECTRICAL EQUIPMENT PAD1 E01A 1"=1'-0" 1.THE METHODS CONTAINED IN CEC/NEC ARTICLE 250 SHALL BE FOLLOWED TO COMPLY WITH GROUNDING AND BONDING OF ELECTRICAL SYSTEMS AND NON-CURRENT CARRYING CONDUCTIVE MATERIALS, ENCLOSURES, OR ITEMS FORMING PART OF ANY SUCH EQUIPMENT THAT ENCLOSES OR CARRIES ELECTRICAL CONDUCTOR OR EQUIPMENT THAT IS LIKELY TO BECOME ENERGIZED. SEE CEC/NEC 250.4(A)(1) THROUGH (5) FOR FURTHER DESCRIPTION, 2.WHERE TWO OR MORE GROUND RODS ARE TO BE INSTALLED, THE MINIMUM SEPARATION SHALL BE 6' PER CEC/NEC 250.53 (A)(2), AND (3) RESISTANCE OF ELECTRODES. 3.ALL CONDUITS SHALL COMPLY WITH CEC/NEC TABLE 300.5 MINIMUM BURIAL DEPTH. 4.PER CEC/NEC 110.26 ”ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF SUCH EQUIPMENT.” 5.CONCRETE PADS SHALL REACH 100% DESIGN STRENGTH PRIOR TO DRILLING FOR ANCHORS. 6.CONTRACTOR TO MEET SCE SWITCHGEAR SPECIFICATIONS. GENERAL NOTES: NOTES: 1.DISTRIBUTION EQUIPMENT BILL OF MATERIALS SEE E01A.909 N Grand Ave - 101116238 & 201806132/15/2024 TO GROUND RODS 39 2524 23 14 40 12 38 5 7 13 C1 BY SCE C2 & C3, 3" PVC, TO DS-SW-1 & DS-SW-2 SECTION B-B 8 1'-8" 2'-10"3'-6" 1'-0"6'-4" 14 21 20 41 31 C6, 3" PVC, TO EV-XFMR 22 22 400/3 400/3 250/3 E0 1 B EL E C T R I C A L D E T A I L S SH E E T DA T E 05 / 1 6 / 2 0 2 3 CH A R G E R E A D Y P R O G A M TO M ' S T R U C K C E N T E R # 2 C R T - 2 0 2 1 - 0 1 1 2 SCALE: ELECTRICAL EQUIPMENT PAD1 E01B 1"=1'-0" 1.THE METHODS CONTAINED IN CEC/NEC ARTICLE 250 SHALL BE FOLLOWED TO COMPLY WITH GROUNDING AND BONDING OF ELECTRICAL SYSTEMS AND NON-CURRENT CARRYING CONDUCTIVE MATERIALS, ENCLOSURES, OR ITEMS FORMING PART OF ANY SUCH EQUIPMENT THAT ENCLOSES OR CARRIES ELECTRICAL CONDUCTOR OR EQUIPMENT THAT IS LIKELY TO BECOME ENERGIZED. SEE CEC/NEC 250.4(A)(1) THROUGH (5) FOR FURTHER DESCRIPTION, 2.WHERE TWO OR MORE GROUND RODS ARE TO BE INSTALLED, THE MINIMUM SEPARATION SHALL BE 6' PER CEC/NEC 250.53 (A)(2), AND (3) RESISTANCE OF ELECTRODES. 3.ALL CONDUITS SHALL COMPLY WITH CEC/NEC TABLE 300.5 MINIMUM BURIAL DEPTH. 4.PER CEC/NEC 110.26 ”ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF SUCH EQUIPMENT.” 5.CONCRETE PADS SHALL REACH 100% DESIGN STRENGTH PRIOR TO DRILLING FOR ANCHORS. 6.CONTRACTOR TO MEET SCE SWITCHGEAR SPECIFICATIONS. GENERAL NOTES: DISTRIBUTION EQUIPMENT BILL OF MATERIALS ITEMREFERENCE NUMBER QUANTITY 9 1/2" DIAMETER SS 316 KWIK BOLT TZ EXPANSION ANCHORS WITH 3 1/4" MIN EFFECTIVE EMBEDMENT. (ICC ESR-1917)AR 10 ARGALVANIZED NUT, 1/2" 11 ARGALVANIZED LOCK WASHER, 1/2" 20 AR3" SCH. 40 PVC, CONDUIT 21 83" SCH. 40 PVC, 90 DEG ELBOW 22 3" SCH. 40 PVC, BELL END 26 12 1 EAILSCO BUS BAR NO. BBFC-4-10-22A KIT OR EQUAL 13 1 EACUSTOMER SUPPLIED PADLOCK 23 61.5" PVC BELL END 24 1.5" SCH. 40 PVC CONDUIT 25 61.5" SCH. 40 PVC, 90 DEG ELBOW AR HPS, TRANSFORMER CASE STYLE DH4, NEMA TYPE 3R, 480-208/120V, 3Ø, 225 KVA1 1 Z POWER SWITCHBOARD, NEMA TYPE 3R, 208/120V, 3Ø, 4W, 600 AMP BUS, 42 KAIC FULLY RATED MAIN BREAKER, 208 VOLT, 500 AMP TRIP, 42 KAIC IR AT 208V, 3 POLE BRANCH BREAKER, GE, TYPE TEYH, 100 AMP TRIP, 42 KAIC, 2 POLE 2 1 3 1 4 4 14 AR2/0 BARE COPPER GROUND WIRE 15 5/8 GROUND ROD COPPER CLAD 10' ERICO INSTALLED VERTICALLY WITH MIN. 1' EARTH COVER 4 16 42/0 TO 5/8 ROD CLAMP, BURNDY MODEL NO. YGHR26C58 8 20A 1-POLE BREAKERS 29 27 28 30 31 AR#1/0 WIRE CONDUCTOR THWN-2 33 AR250 KCMIL WIRE CONDUCTOR THWN-2 5/8" DIAMETER SS 316KWIK BOLT TZ EXPANSION ANCHORS WITH 32 AR#8 WIRE CONDUCTOR THWN-2 4 34 AR#2 WIRE CONDUCTOR THWN-2 37 35 36 3/4" SCH, 40 PVC, CONDUIT 3/4" SCH, 40 PVC, 90 DEG ELBOW 4 AR 3/4" SCH. 40 PVC, BELL END 4 5 Z POWER SWITCHBOARD WITH METER, NEMA 3R, 480/277V, 3Ø, 4W, 1000A, 65 KAIC FULLY RATED, TWO SECTIONS 1 6 MAIN BREAKER, 480V, 1000A, 65 KAIC, 3 POLE 1 7 2BRANCH BREAKER, 480V, 400A, 65 KAIC, 3 POLE 8 BRANCH BREAKER, 480V, 250A, 65 KAIC, 3 POLE 1 38 SCH. 40 PVC CONDUIT, SIZE BY SCE 39 ARSCH. 40 PVC CONDUIT RADIUS, SIZE BY SCE 40 SCH. 40 PVC CONDUIT BELL END, SIZE BY SCE AR AR 41 AR500 KCMIL WIRE CONDUCTOR THWN-2 GALVANIZED NUT, 5/8" GALVANIZED LOOK WASHER, 5/8" NOT USED 3 1/4" MIN EFFECTIVE EMBEDMENT. AR AR AR 6/30/20256-30-2025 909 N Grand Ave - 101116238 & 201806132/15/2024 3' - 6 " 2' - 4 " 10 3 2 C2,C4, 3" PVC 6" 2'-0" BTC POWER CABINET POWER CABINET AND PAD SHOWN FOR REFERENCE ONLY. DESIGN AND INSTALLATION BY CUSTOMER SECTION A-A 6" MIN C2,C4, 3" PVC FROM SWBD-A TO 400A DS-SW-1 AND DS-SW-2 2'-0" 3 2 10 13 6 BTC POWER CABINET (BY CUSTOMER) THE DESIGN AND INSTALLATION OF THE POWER CABINET (BY CUSTOMER) AND POWER CABINET FOUNDATION (BY CUSTOMER) ARE OUTSIDE THE SCOPE OF THIS DOCUMENT 1616 C3,C5, 3" PVC A A C8-C11, 1.5" PVC FREE WIRE FREE WIRE AND PAD SHOWN FOR REFERENCE ONLY. DESIGN AND INSTALLATION BY CUSTOMER SECTION A-A FREE WIRE DISPENSRE (BY CUSTOMER) THE DESIGN AND INSTALLATION OF THE FREE WIRE (BY CUSTOMER) AND FREE WIRE FOUNDATION (BY CUSTOMER) ARE OUTSIDE THE SCOPE OF THIS DOCUMENT C12-C15, 1.5" PVC PLAN VIEW A A 1'-6" 6" MIN 18 " 21 . 2 5 " 6.4" 2' - 0 " 1'-6" 6" 1 3 2 4 6 5 2 3 1 PLAN VIEW BTC POWER CABINET FREE WIRE STUB-UP AND CAP CONDUIT FOR CONNECTION TO EV EQUIPMENT VERIFY STUB-UP LOCATION WITH SCE. STUB-UP AND CAP CONDUIT FOR CONNECTION TO EV EQUIPMENT VERIFY STUB-UP LOCATION WITH SCE. C8-C11, 1.5" PVC 12 4 12 4 11 16 11 E0 2 EL E C T R I C A L D E T A I L S EV CHARGING PAD BILL OF MATERIALS 1 ITEMREFERENCE NUMBER QUANTITY 100A, 3P, 3W, 208V, 42KA, NEMA 3R SINGLE THROW FUSED SAFETY SWITCH.4 EA 2 AR 3 1-5/8" GALVANIZED STEEL UNISTRUT 3 EA4 5 3 EA AR SCALE: 208V EV CHARGING STATION AND DISCONNECT1 E02 1"=1'-0" 2-1/2" GALVANIZED STEEL POST 1.5" SCH. 40 PVC, RADIUS 1.5" PVC BELL END, CANTEX OR EQUAL 1.EV CHARGING STATION AND PAD DETAIL IS TYPICAL DETAIL FOR ALL CHARGING STATIONS. THIS DETAIL CAN BE USED FOR EV CHARGING STATIONS. 2.DISCONNECT SWITCHES TO BE CAPABLE OF BEING LOCKED IN THE OPEN POSITION. 3.CONTRACTOR TO FIELD VERIFY DESIGN. FINAL INSTALLED MOUNTING DEVICE AND CONDUITS MAY VARY FROM WHAT IS SHOWN HERE. 4.CONTRACTOR TO VERIFY FINAL STUB-OUT LOCATIONS WITH SCE. 5.EV CHARGING EQUIPMENT HAS BEEN SPECIFIED AS: BTC POWER CABINETS HPCT2-200-480-2 AND FREEWIRE-BOOST CHARGER 150KW GENERAL NOTES: 6 ARUV STABILIZED NYLON CABLE TIES SH E E T DA T E 05 / 1 6 / 2 0 2 3 CH A R G E R E A D Y P R O G A M TO M ' S T R U C K C E N T E R # 2 C R T - 2 0 2 1 - 0 1 1 2 SCALE: 480V EV CHARGING STATION AND DISCONNECT2 E02 1"=1'-0" 10 400A 3P, 3W, 480V 65KA, NEMA 3R, SINGLE THROW FUSED SAFETY SWITCH 2 EA 11 AR 12 1.5" PVC SCH. 40 PVC CONDUIT 3 EA13 14 AR 3" SCH. 40 PVC CONDUIT 3" SCH. 40 PVC, CONDUIT BELL END 16 3 EA NOT USED 3" SCH. 40 PVC, CONDUIT 36" RADIUS 909 N Grand Ave - 101116238 & 201806132/15/2024 SCALE: SINGLE LINE DIAGRAM (480V)2 E03 NONE E0 3 EL E C T R I C A L S L D TO BTC-#1 400A 3P MAIN SWITCHBOARD "PEV-A" , 1000A BUS,1000A MAIN, 480V/277V, 3Ø, 4W, 65 KAIC FULLY RATED, 12 SPACES, NEMA 3R M 1000A 3P LSIG SEE NOTE 9 METERING SECTIONPULL SECTION LANDING LUGS C1 SH E E T DA T E 05 / 1 6 / 2 0 2 3 CH A R G E R E A D Y P R O G A M TO M ' S T R U C K C E N T E R # 2 C R T - 2 0 2 1 - 0 1 1 2 400A 3P 250A 3P 400A FUSED DISCONNECT SWITCH (TYP.) C2 C3 1.POWER CABINET: BTCPOWER HPCT-200-480-2 2.BRANCH BREAKERS SHALL BE RATED FOR 65 KAIC. 3.SERVICE PANEL, OVER CURRENT PROTECTION DEVICES AND WIRE SIZE BASED ON CEC/NEC REQUIREMENTS AT 125% CONTINUOUS LOAD. 4.EQUIPMENT GROUND CONDUCTOR (EGC) #3 AWG GREEN INSULATED USED FOR CHARGERS, SEE CONDUIT SCHEDULE. 5.ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. 6.PER CEC/ NEC 210.19 (A) INFORMATIONAL NOTE #4, "CONDUCTORS FOR BRANCH CIRCUITS AS DEFINED IN ARTICLE 100, SIZED TO PREVENT A VOLTAGE DROP EXCEEDING 3 PERCENT AT THE FARTHEST OUTLET OF POWER, HEATING, AND LIGHTING LOADS, OR COMBINATION OF SUCH LOADS, AND WHERE THE MAXIMUM TOTAL VOLTAGE DROP ON BOTH FEEDERS AND BRANCH CIRCUITS TO THE FARTHEST OUTLET DOES NOT EXCEED 5%." 7.THE METHODS CONTAINED IN CEC/NEC ARTICLE 250 SHALL BE FOLLOWED TO COMPLY WITH GROUNDING AND BONDING OF ELECTRICAL SYSTEMS AND NON-CURRENT CARRYING CONDUCTIVE MATERIALS, ENCLOSURES, OR ITEMS FORMING PART OF ANY SUCH EQUIPMENT THAT ENCLOSES OR CARRIES ELECTRICAL CONDUCTOR OR EQUIPMENT THAT IS LIKELY TO BECOME ENERGIZED. SEE CEC/NEC 250.4(A)(1) THROUGH (5) FOR FURTHER DESCRIPTION. 8.WHERE TWO OR MORE GROUND RODS ARE TO BE INSTALLED, THE MINIMUM SEPARATION SHALL BE 6' PER CEC/NEC 250.53 (A)(2), AND (3) RESISTANCE OF ELECTRODES. 9.GFPE SYSTEM MUST BE TESTED BY A QUALIFIED PERSON. THE TEST IS TO BE THE PRIMARY CURRENT INJECTION METHOD AND A WRITTEN REPORT MUST BE PROVIDED TO THE AHJ PRIOR TO SERVICE RELEASE FOR ENERGIZATION. GENERAL NOTES: EV-SWBD-1 1000A, 480/277V, 3Ø, 4W, 65 KAIC FULLY RATED NEMA 3R 1000A 1 3 400A 5 7 9 11 A B C BTC #1 SCALE: EV-SWBD-1 LOAD SCHEDULE1 E03 NONE 2 4 6 8 10 12 BTC #2 400A LOAD SUMMARY TABLE A KVA B KVA C KVA WIRE SIZE DESCRIPTION BREAKER POSITION BTC #1 73.16 73.16 600KCMIL 1 3 5 2 4 6 7 9 11 8 10 12 186.32 186.32 186.32 TOTAL KVA/BUS TOTAL KVA558.96 NOTE: BUS HAS BEEN SIZED FOR HIGHEST AMPACITY 186.32 KVA @ 277V = 672.64 A 125% x 672.64 A = 840.79 A 73.16 250A 73.16 73.16 73.16 40 40 40 BTC #2 EV XFMR C4 C5 C6 TO BTC-#2 TO EV XFMR SEE E04 DETAIL 2 EV XFMR BLANK BLANK 600KCMIL 600KCMIL 600KCMIL 600KCMIL 600KCMIL 250KCMIL SCE XFMR 480/277V, 3Ø,4W (2) 5/8" X 10' GROUND RODS (MIN. 6' SEPARATION) GROUNDING ELECTRODE CONDUCTOR (GEC) 2/0 LI N E LO A D A A B C 480/277V PER SCE LI N E LO A D B LI N E LO A D C C1, BY SCE N N 250KCMIL 250KCMIL G N (2) 5/8" X 10' GROUND RODS (MIN. 6' SEPARATION) 6/30/20256-30-2025 909 N Grand Ave - 101116238 & 201806132/15/2024 SCALE: SINGLE LINE DIAGRAM (208/120V)2 E04 NONE E0 4 EL E C T R I C A L S L D TO FREE WIRE #1 100A 3P EV-SWDB-2 600A BUS, 500A MAIN, 208/120V, 3Ø, 4W, 42 KAIC NEMA 3R500A 3P C7 SH E E T DA T E 05 / 1 6 / 2 0 2 3 CH A R G E R E A D Y P R O G A M TO M ' S T R U C K C E N T E R # 2 C R T - 2 0 2 1 - 0 1 1 2 100A 3P 100A 3P 100A 3P 100A FUSED DISCONNECT SWITCH (TYP.) C8 C9 C10 C11 1.DUAL PORT: FREEWIRE-BOOST CHARGER 150 2.BRANCH BREAKERS SHALL BE RATED FOR 42 KAIC. 3.SERVICE PANEL, OVER CURRENT PROTECTION DEVICES AND WIRE SIZE BASED ON CEC/NEC REQUIREMENTS AT 125% CONTINUOUS LOAD. 4.EQUIPMENT GROUND CONDUCTOR (EGC) #8 AWG GREEN INSULATED USED FOR CHARGERS, SEE CONDUIT SCHEDULE. 5.ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. 6.PER CEC/ NEC 210.19 (A) INFORMATIONAL NOTE #4, "CONDUCTORS FOR BRANCH CIRCUITS AS DEFINED IN ARTICLE 100, SIZED TO PREVENT A VOLTAGE DROP EXCEEDING 3 PERCENT AT THE FARTHEST OUTLET OF POWER, HEATING, AND LIGHTING LOADS, OR COMBINATION OF SUCH LOADS, AND WHERE THE MAXIMUM TOTAL VOLTAGE DROP ON BOTH FEEDERS AND BRANCH CIRCUITS TO THE FARTHEST OUTLET DOES NOT EXCEED 5%." 7.THE METHODS CONTAINED IN CEC/NEC ARTICLE 250 SHALL BE FOLLOWED TO COMPLY WITH GROUNDING AND BONDING OF ELECTRICAL SYSTEMS AND NON-CURRENT CARRYING CONDUCTIVE MATERIALS, ENCLOSURES, OR ITEMS FORMING PART OF ANY SUCH EQUIPMENT THAT ENCLOSES OR CARRIES ELECTRICAL CONDUCTOR OR EQUIPMENT THAT IS LIKELY TO BECOME ENERGIZED. SEE CEC/NEC 250.4(A)(1) THROUGH (5) FOR FURTHER DESCRIPTION. 8.WHERE TWO OR MORE GROUND RODS ARE TO BE INSTALLED, THE MINIMUM SEPARATION SHALL BE 6' PER CEC/NEC 250.53 (A)(2), AND (3) RESISTANCE OF ELECTRODES. GENERAL NOTES:EV-SWBD-2 600A BUS, 500A MAIN, 208/120V, 3O, 4W, 42 KAIC FULLY RATED NEMA 3R C B A N G 500A 1 3 100A 5 7 9 11 A B C FREE WIRE #1 SCALE: EV-SWBD-2 LOAD SCHEDULE1 E04 NONE 2 4 6 8 10 12 FREE WIRE #2 100A LOAD SUMMARY TABLE A KVA B KVA C KVA WIRE SIZE DESCRIPTION BREAKER POSITION FREE WIRE #1 9.6 9.6 #1 1 3 5 2 4 6 7 9 11 8 10 12 40.8 39.6 39.6 TOTAL KVA/BUS TOTAL KVA120 NOTE: BUS HAS BEEN SIZED FOR HIGHEST AMPACITY 40.80 KVA @ 120V = 340 A 125% x 340 A = 425 A 9.6 100A 100A 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 FREE WIRE #2 FREE WIRE #3 FR O M E V - X F M R EV-XFMR 150 KVA 480-208/120V, 3Ø NEMA 3R C12 C13 C14 C15 C6 (2) 5/8" X 10' GROUND RODS (MIN. 6' SEPARATION) TO FREE WIRE #2 TO FREE WIRE #3 TO FREE WIRE #4 FREE WIRE #3 FREE WIRE #4 #1 #1 #1 #1 #1 #1 #1 #1 #1 #1 #1 FREE WIRE #4 GROUNDING ELECTRODE CONDUCTOR (GEC) 2/0 FROM EV-SWBD-2 SEE E03 DETAIL 2 13 15 17 14 16 18 20A 20A DISPENSER 1A BLANK 13 15 17 1.2 1.2 1.2 #12 #12 #12 #12 14 16 18 20A 20A DISPENSER 1B DISPENSER 2A DISPENSER 2B DISPENSER 1A DISPENSER 1B DISPENSER 2A DISPENSER 2B1.2 BLANK BLANK 20A 1P AUX. POWER TO BTC#1 DISPENSER A 20A 1P 20A 1P 20A 1P G N AUX. POWER TO BTC#1 DISPENSER B AUX. POWER TO BTC#2 DISPENSER A AUX. POWER TO BTC#2 DISPENSER B 6/30/20256-30-2025 909 N Grand Ave - 101116238 & 201806132/15/2024