HomeMy WebLinkAbout940 E Anahurst Pl & 2201 S Halladay - PlanGENERAL NOTES
1. CONTRACTOR SHALL STUDY THE DRAWINGS, SPECIFICATIONS AND FIELD CONDITIONS
BEFORE COMMENCING WITH THE WORK INVOLVED. ANY DISCREPANCIES FOUND SHALL
BE REPORTED TO THE OWNER IN WRITING FOR CORRECTIONS OR CLARIFICATION.
2. PROVIDE SHORING AT ALL TIMES WHEN ALTERING VERTICAL MEMBERS. CONTRACTOR
SHALL VERIFY ACTUAL CONDITIONS AND REPORT IN WRITING TO THE ARCHITECT FOR
RESOLUTION PRIOR TO PROCEEDING WITH THE WORK.
3. THE AREA OF GLASS IN WINDOWS LIMITED TO 20% OF THE FLOOR ADDITION PLUS THE
AREA OF ANY GLASS THAT WAS ELIMINATED IN THE ORIGINAL RESIDENCE WALL AREA
WHERE THE NEW ADDITION IS ATTACHED. ALL NEW WINDOWS SHALL BE DUAL-GLAZED.
4. ALL WINDOWS ARE TO BE WEATHER STRIPPED.
5. SMOKE DETECTORS SHALL BE INSTALLED IN AREAS GIVING ACCESS TO SLEEPING
ROOMS ON OR NEAR THE CEILING, IN EACH SLEEPING ROOM (CBC 310.9.1-4).
6. ATTIC VENTILATION, EQUAL TO 1/150 OF SPACE VENTILATED, SHALL BE PROVIDED OR AS
REQUIRED FOR FORCED AIR UNIT.
7. UTILITY LINES AND ACCESSORIES FOUND AT THE SITE THAT INTERFERE WITH THE NEW
CONSTRUCTION SHALL BE RELOCATED AS NECESSARY. THE CONTRACTOR SHALL
OBTAIN ANY BUILDING PERMIT REQUIRED.
8. ALL WOOD IN CONTACT WITH CONCRETE AND FOUNDATION SILLS SHALL BE PRESSURE
TREATED.
9. PROVIDE CORROSION RESISTED WEEP SCREED AT FOUNDATION PLATE LINE WHICH
WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING. 4"
MINIMUM HEIGHT ABOVE GRADE.
10. WALLS CONTAINING 3" OR 4" DIAMETER DRAIN/WASTE/VENT PIPING SHALL BE SIZED TO
ALLOW CUTTING/NOTCHING/BORING (2 X 6 MIN.).
11. CAULK/SEAL ALL PENETRATIONS TO TOP AND BOTTOM PLATES.
12. CAULK/SEAL ALL EXTERIOR BOTTOM PLATES.
13. INSULATION : WALLS R-15 / CEILING R-30 / FLOOR R-19
14. ALL EXTERIOR FINISH MATERIAL TO MATCH EXISTING IN TYPE AND COLOR.
15. ALL NEW ELECTRICAL WIRING SHALL BE COPPER.
16. PROVIDE SEPARATE INSPECTION FOR EACH PHASE OF EXTERIOR PLASTER AS
FOLLOWS : SCRATCH COAT, BROWN COAT , COLOR COAT [ STAPLES ARE NOT
PERMITTED FOR ATTACHING WIRE ].
17. BUILDING PAPER TO BE USED # 60 FOR STUCCO THAT DOES NOT HAVE PLYWOOD
BACKING.
18. DUCTS SHALL BE SIZED PER CHAPTER 6 OF THE MECHANICAL CODE.
19. DISTANCE FROM FACE OF THE FOUNDATION TO PROPERTY LINE TO BE ZONING SETBACK
PLUS WALL FINISH THICKNESS (MINIMUM).
20. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO
SOLID WASTE MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITES OR
BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE
STREET, GUTTER OR STORM DRAIN SYSTEM.
21. THE INSULATION INSTALLER AND THE CONTRACTOR SHALL POST A SIGNED CERTIFICATE
OF COMPLIANCE IN A CONSPICUOUS LOCATION IN THE BUILDING. THIS CERTIFICATE
SHALL STATE THAT THE INSTALLATIONS AND MATERIALS CONFORM TO THE
APPROPRIATE SECTIONS OF THE CALIFORNIA ADMINISTRATIVE CODE, TITLES 20 AND 24
AND SHALL SPECIFY THE MANUFACTORE'S NAME AND MATERIAL IDENTIFICATION, THE
INSTALLED R-VALUE, AND WHEN LOOSE FILL IS INSTALLED, SHALL STATE THE MINIMUM
INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH THE MANUFACTURE'S
LABELED DENSITY FOR THE DESIRED R-VALUE.
22. ALL INTERIOR DOORS TO BE HOLLOW CORE 1 3/8" THICK U.N.O., (SEE PLAN FOR SIZE). AT
DOUBLE INTERIOR DOOR CONDITIONS PROVIDE DEADBOLT AT TOP OF INACTIVE DOOR.
23. ALL EXTERIOR FRENCH DOORS TO BE SOLID CORE 1 3/4" THICK. (SEE PLAN FOR SIZE). AT
DOUBLE FRENCH DOORS PROVIDE DEADBOLT AT TOP AND BOTTOM OF INACTIVE DOOR
W/ TEMP. GL.
24. CONTRACTOR SHALL VERIFY WITH WINDOW MANUFACTURER THAT ALL ESCAPE OR
RESCUE WINDOWS HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET, GRADE
FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 FT. THE MIN. NET
CLEAR OPENING HEIGHT SHALL BE 24". THE MINIMUM NET CLEAR OPENING WIDTH SHALL
BE 20" AND THE BOTTOM OF THE CLEAR OPENING NO GREATER THAN 44" ABOVE THE
FLOOR (C.R.C. R310.1). WINDOWS NOT MEETING THESE REQUIREMENTS SHALL BE
BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER.
25. DUCTS PENETRATING WALL OR CEILING PENETRATIONS BETWEEN GARAGE AND
DWELLING UNIT SHALL BE CONSTRUCTED OF 26 GAGE MIN. SHEET METAL AND SHALL
HAVE NO OPENING INTO GARAGE - PER SEC R302.5.2
26. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE FOOT CLEAR AND AN OBSTRUCTED
ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES.PULL
BOXES,TRANSFORMERS, VAULTS,PUMPS,VALVES,METERS,APPURTENANCE ETC,) OR THE
LOCATION OF THE HOOK UPS.
27. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES WHEATHER
OR NOT THE LINES ARE LOCATED ON THE PROPERTY.FAILURE TO COMPLY MAY CAUSE
CONSTRUCTION DELAYS AND/ OR ADDITIONAL EXPENSES
28. AN APPROVED SEISMIC GAS SHUT OFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE
ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO
THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS
PIPING.(PER ORDINANCE170.156) (INCLUDES COMMERCIAL ADDITIONS AND IT WORK
OVER $10,000) SEPARATE PLUMBING PERMIT IS REQUIRED.
29. PROVIDE ULTRA LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION.EXISTING
SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION.
30. WATER HEATER MUST BE STRAPPED TO WALL (SEC.5013 LAPC)
31. SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDEDFOR
HUMAN OCCUPANCY, UPON THE OWNER'S APPLICATION FOR A PERMIT FOR
ALTERATIONS,REPAIRS,OR ADDITIONS EXCEEDING ONE THOUSAND DOLLARS ($1,000)
(R314.6.2)
32. WHERE A PERMIT IS REQUIRED FOR ALTERATIONS,REPAIRS OR ADDITIONS EXCEEDING
ONE THOUSAND DOLLARS ($1,000) EXISTING DWELLING OR SLEEPING UNITS THAT HAVE
ATTACHED GARAGES OR FUEL BURNING APPLIANCES SHALL BE PROVIDED WITH A
CARBON MONOXIDE ALARM IN ACCORDANCE WITH SECTION R3151.CARBON MONOXIDE
ALARMS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING
UNITS FOR WHICH THE PERMIT WAS OBTAINED (R315 .2).
33. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL
LIGHT BY MEANS OF EXTERIOR GLAZED OPENING IN ACCORDANCE WITH SECTION R303.1
OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN
AVERAGE ILLUMUNATION OF 6 FOOT -CANDLES OVER THE AREA OF THE ROOM, AT A
HEIGHT OF 30 INCHES ABOVE THE FLOOR LEVEL (R303.1)
34. THE ADU SF / SFD SF RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE APPLICANT IS
RESPONSIBLE FOR THE GIVEN “SFR SF” OF THE EXISTING PRIMARY RESIDENCE;
BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN
“SFR SF” OF THE EXISTING RESIDENCE.
GENERAL REQUIREMENTS
1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2022 EDITION OF THE CBC,CRC,CMC,CPC,
AND CEC AS ADOPTED AND AMENDED BY THE STATE OF CALIFORNIA IN TITLE 24 CCR
AND HIS JURISDICTION.
2. SEPARATE PERMITS MAY BE REQUIRED FOR SHORING, GRADING, AND DEMOLITION.
3. ALL PROPERTY LINES,EASEMENTS,AND EXISTING BUILDINGS HAVE BEEN INDICATED ON
THIS SITE PLAN.
4. A SECURITY FENCE SHALL BE PROVIDED AROUND THE CONSTRUCTION AREA THAT
SHALL BE INTALLED PRIOR TO EXCAVATION AND OR FOUNDATION TRENCHING.
5. WATER SHALL BE PROVIDED ON THE SITE AND USES TO CONTROL DUST.
6. TEMPORARY TOILET FACILITIES SHALL BE PROVIDED ON SITE.
7. THE FINISH GRADE SHALL SLOPE A MIN. OF 5%,OR 6",TO A POINT 10 FEETFROM BUILDING
FOUNDATION,OR TO AN APPROVED ALTERNATE METHOD OF DIVERTING WATER AWAY
FROM THE FOUNDATION. SWALES SHALL SLOPE A MINIMUM OF 2%. (CRC R401.3)
8. THE TOP OF THE EXTERIOR FOUNDATION SHALL EXTEND ABOVE THE ELEVATION OF THE
STREET GUTTER A MINIMUM 12" OR PLUS 2 % (CRC R403.1.7.3)
FIRE PROTECTION
1. AN APPROVED SMOKE ALARMS SHALL BE INSTALLED IN EACH SLEEPING ROOM AND
HALLWAY OR AREA GIVING ACCESS TO A SLEEOING ROOM, AND EACH STORY AND
BASEMENT FOR DWELLING WITH MORE THAN ONE STORY,SMOKE ALARMS SHALL BE
INTERCONNECTED SO THAT ACTUATION OF A ONE ALARM WILL ACTIVATE ALL THE
ALARMS WITHIN THE INDIVIDUAL DWELLING UNIT.IN NEW CONSTRUCTION SMOKE
ALARMS SHALL RECIEVE THEIR PRIMARY POWER SOURCE FROM THE BUILDING WIRING
AND SHALL BE EQUIPPED WITH BATTERY BACK UP AND LOW BATTERY SIGNAL (R314).
2. AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS AND
IN SLEEPING UNITS.WITHIN WHICH FEL-BURNING APPLIANCES ARE INSTALLED AND IN
DWELLING UNITS THAT HAVE ATTACHED GARAGES,CARBON MONOXIDE ALARM SHALL BE
PROVIDED OUTSIDE OF EACH SEPARATE DWELLING UNITS SLEEPING AREA IN THE
IMMEDIATE VICINITY OF THE BEDROOMS AND ON EVERY LEVEL OF A DWELLING UNIT
INCLUDING BASEMENT (R315)
SCOPE OF WORK
• EXISTING 400 SQ.FT. GARAGE + NEW 280 SQ.FT. ADD TO BE AN ADU / TOTAL:
680 SQ.FT.
• LAUNDRY NEXT TO THE GARAGE WILL BE DEMOLISHED.
• DEFERRED PROPERTY LINE FENCE SUBMITTAL
ALL WORK SHALL COMPLY WITH THE FOLLOWING CODES
• 2022 CALIFORNIA RESIDENTIAL CODE
• 2022 CALIFORNIA ELECTRICAL CODE
INTERNATIONAL CODE COUNCIL
• 2022 CALIFORNIA BUILDING CODE (C.B.C.)
• 2022 CALIFORNIA BUILDING ENERGY STANDARDS
• 2022 CALIFORNIA RESIDENTIAL CODE (C.R.C.)
• ORANGE COUNTY FIRE AUTHORITY
• 2022 CALIFORNIA MECHANICAL CODE
• 2022 CALIFORNIA PLUMBING CODE
• CITY MUNICIPAL CODE
RESIDENTIAL GENERAL REQUIREMENTS CHECK LIST
1. CONCRETE STRENGHT: 2,500 p.s.i. PER 2022 CRC R404,1,2,3,1, @ 28 DAYS. USE TYPE II OR V CEMENT. SPECIAL
INSPECTION IS NOT REQ'D.
2. STEEL REINFORCEMENT: GRADE 60, DEFORMED. PER CRC R404.1.2.3.7.1
3. ANCHOR BOLTS: A-307.
4. LUMBER: USE DOUGLAS FIR, LARCH No. 2 OR BETTER UNLESS OTHERWISE NOCOTED ON FRAMING PLANS.
5. USE 2-15# FELT BACKING WHEN STUCCO IS APPLIED OVER PLYWOOD, UBC SEC. 2501.4.
6. ALL WORK SHALL COMPLY WITH THE FOLLOWING CODES INCLUDING LOCAL AMENDMENTS.
RESIDENTIAL GENERAL REQUIREMENTS CHECK LIST
1. THE FOLLOWING IS INTENDED AS AN ATTACHMENT FOR CONSTRUCTION AND GRADING PLANS AND REPRESENT THE
MINIMUM STANDARDS OF HOUSEKEEPING WHICH MUST BE IMPLEMENTED ON ALL CONSTRUCTION SITESREGARDLESS
OF SIZE.
2. ERODED SEDIMENTS AND OTHE POLLUTANTSMUST BE RETAINED ON SITE AND MAY NOT BE TRANSPORTED FROM THE
SITE VIA SHEET FLOW, SWALES, AREA DRAINS, NATURAL DRAINAGE OR WIND.
3. STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE RETAINED ON SITE AND MAY NOT
BE TRANSPORTED FROM THE SITE VIA SHEET FLOW, SWALES, AREA DRAINS, NATURAL DRAINAGE OR WIND.
4. FUELS, OILS, SOLVENTS AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTING AND ARE
NOT TO CONTAMINATE THE SOIL AND SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO PROTECTED
FROM THE WEATHER. SPILLS MUST BE CLAENED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY
NOT BE WASHED INTO THE DRAINAGE SYSTEM.
5. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO HE PUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM.
PROVISIONS SHALL BE MADE TO RETAIAN CONCRETE WASTES ON SITE UNTIL THEY CAN BE DIPOSED OF AS SOLID
WASTE
6. TRASH AND CONSTRUCTION RELATED SOLID WASTES MUST BE DEPOSITED INTO A COVERED RECEPTACLE TO PREVENT
CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND.
7. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION
ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC
WAY. ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR
OTHER MEANS.
8. ANY SLOPES WITH DISTURBED SOILSOR DENUDED OF VEGITATION MUST BE STABILIZED SO AS TO INHIBIT EROSIOP
EROSION BY WIND AND WATER.
Property Information
Assessor's ID No:016-105-18
Address:2201 HALLADAY ST
STA ANA, CA 92707
Property Type:Single Family Residential
Lot Area:6,842 sq.ft.
Property Boundary Description
N-TRACT: 668 BLOCK: R LOT: 1
Building Description
Square Footage: 1,661
Year Build / Effective Year Built: 1901 / 1901
Bedrooms / Bathrooms 3 / 1
Units 1
PROPERTY INFORMATION
VICINITY MAP
Lot Area 6,842 sq.ft.
Existing SFD 1,661 sq.ft.
Ex. Garage to be an ADU 400 sq.ft.
New ADD to garage 280 sq.ft.
Ex. Porch 85 sq.ft.
Total square footage: SFD + ADU
1,661 sq.ft. 680 sq.ft.
= 2,341 sq.ft.
Ratio = 680 sq.ft. / 1,661 sq.ft. = 40.93 %
Lot Coverage = 2,426 sq.ft./6,842 sq.ft.= 35.45 %
Occupancy Group: R-3
Construction Type: V-B
Number of stories: One
Fire Sprinklers (E) house: None exists
Fire Sprinklers (N) ADU: None proposed
SQUARE FOOTAGE
INDEX
PLAN DESCRIPTION
00-G-01 PROJECT INFO
00-G-01
.1
PROPOSED SITE
01-A-01 EXISTING SITE PLAN & EXISTING FLOOR
PLAN-MAIN HOUSE
01-A-02 EXISTING ROOF PLAN-MAIN HOUSE & EXISTING
ELEVATIONS-MAIN HOUSE
01-A-03 EXISTING FLOOR&ROOF PLAN, PROPOSED
FLOOR&ROOF PLAN
01-A-04 PROPOSED UTILITY FLOOR PLAN / ISOMETRIC
VIEW
01-A-05 ELEVATIONS & SECTIONS
01-A-06 PHOTOGRAPHS OF EXISTING SITE CONDITIONS
02-S1.0 STRUCTURAL NOTES
02-S1.1 TYPICAL DETAILS
02-S1.2 TYPICAL DETAILS
02-S1.3 TYPICAL DETAILS
02-S2.0 FOUNDATION PLAN
02-S2.1 ROOF FRAMING PLAN
02-S3.0 FOUNDATION DETAILS
02-S5.0 ROOF FRAMING DETAILS
03-G-01 GREEN CODE
03-G-02 GREEN CODE
03-G-03 TITLE 24 REPORT
03-G-04 TITLE 24 REPORT
05-E-01 GENERAL NOTES
Project number
Date
Drawn by
Checked by
E-mail:skyaaconstruction@gmail.com
THIS DESIGN AND DRAWINGS, ARE
COPYRIGHT PROTECTED AND ARE
THE EXCLUSIVE PROPERTY OF AA SKY
CONSTRUCTION INC., THEY SHALL BE
NO USED, MODIFIED DUPLICATED IN
WHOLE OR IN ANY MANNER, NOR
ASSIGNED TO A THIRD PARTY WITHOUT
THE WRITTEN AUTHORIZATION
OF AA SKY CONSTRUCTION INC.
APPROVAL STAMP
OWNER
CONTACT PERSON
DESIGNER
AA SKY CONSTRUCTION INC.
2074 SILVERADO ST.
SAN MARCOS CA 92078
LIC#1061749
OFFICE 858 888 3752
CELL 760 845 7697
RAFAEL G LUJANO
E-MAIL: SKYAACONSTRUCTION@GMAIL.COM
CONSULTANTS
00-G-01
PROJECT INFO
0001
940 E ANAHURST PL.
STA. ANA, CA 92707
05-20-2024
Lucas
-
EX. 400 SQ.FT.
GARAGE+ NEW 280
SQ.FT. TO BE A 680
SQ.FT. ADU
RAFAEL LUJANO
RAFAEL LUJANO
2201 HALLADAY ST. STA. ANA, CA 92707
skyaaconstruction@gmail.com
+17608457697
No. Description Date
1 Revisión 1 Fecha 1
CITY NOTES:
BUILDING SECURITY REGULATIONS: FOR NEW BUILDINGS AND ADDITIONS, ALTERATIONS, AND REPAIRS WITHIN ANY TWELVE-
MONTH PERIOD EXCEED FIFTY (50%) PERCENT OF THE VALUE OF ANY EXIS TING BUILDING OR STRUCTURE, EACH BUILDING
OR STRUCTURE SHALL BE MADE TO CONFORM TO THE REQUIREMENTS FOR NEW BUILDINGS OR STRUCTURES AND COMPLY
WITH THE BUILDING SECURITY REGULATIONS. SANTA ANA MUNICIPAL CODE CHAPTER 8, DIVISION 3.
BLDG # 101120172-73
APPROVALS
BLDG - CSG Consultants
PLNG - HJacinto
POLICE - BMartin
940 E Anahurst Pl & 2201
S Halladay11/25/2024
N
13
'
-
1
"
9'
-
0
"
1'
-
1
0
"
12
'
-
7
"
1'
-
1
1
"
11
'
-
2
"
52
'
-
6
"
13' - 3"4' - 0"
18' - 6"
12' - 3"
7'
-
2
"
11
'
-
3
"
12
'
-
6
"
13
'
-
9
"
46
'
-
7
"
16' - 0"14' - 3"
31' - 6"
Ex. Room #3
Ex. Master Bathroom
Ex. CL Ex. CL
Ex. Hallway
Ex. Kitchen
Ex. Dining Room
Ex. Room #2
Ex. Room #1
Ex. Closet
Ex. Living Room
Ex.Patio Cover (To be
demolished under a
separate permit)
Ex. Closet
Ex. Pantry
W.H.
Ex. Bathroom
EX
.
5
'
x
5
'
S
L
I
D
I
N
G
W
I
N
D
.
EX
.
5
'
x
5
'
S
L
I
D
I
N
G
W
I
N
D
.
EX. 5'x6' SLIDING WIND.EX. 4'x6' SINGLE HUNG WIND.
EX. 2.5'x4' SINGLE HUNG WIND.
EX
.
4
'
x
3
'
S
L
I
D
I
N
G
W
I
N
D
.
EX
.
6
'
x
4
'
S
L
I
D
I
N
G
W
I
N
D
.
EX
.
6
'
x
4
'
S
L
I
D
I
N
G
W
I
N
D
.
EX
.
8
'
-4"
x
4
'
S
L
I
D
I
N
G
W
I
N
D
.
EX. 2'x5' SINGLE HUNG WIND.
EX. 2'x5' SINGLE HUNG WIND.
Ex. Water Heater 40 Gals.
Model No. XG40T09EN38U0
Ex. Porch
4'
-
9
"
22' - 7"
NEW LAUNDRY LOCATION
UNDER A SEPARATE PERMIT
SUBMITTED.
EX. WALL TO REMAIN
WALL SCHEDULE
EX. 1,661 SQ.FT. SFD
(NO SPRINKLERS)
EX
.
D
R
I
V
E
W
A
Y
AP
P
R
O
A
C
H
N
EX. LANDSCAPE
EX. WALKWAY
EX. DRIVEWAY
EX. CONCRETE
PROPERTY LINE 50'
S HALLADAY ST.
7' - 0"31' - 6"6' - 0"5' - 6"
13
'
-
6
"
PROPERTY LINE 50'
PR
O
P
E
R
T
Y
L
I
N
E
1
3
6
'
-10
"
PR
O
P
E
R
T
Y
L
I
N
E
1
3
6
'
-10
"
EX. LANDSCAPE
EX. LANDSCAPE
2% MIN
SLOPE
2% MIN
SLOPE
2% MIN
SLOPE
2% MIN
SLOPE
5% MIN
SLOPE
EX. GAS
METER
Ex. ELEC. PANEL
Sidewalk
EX. WATER METER
Si
d
e
w
a
l
k
EX. 400 S.F. GARAGE
(NO SPRINKLERS)
30
'
-
0
"
39
'
-
0
"
13
'
-
6
"
29
'
-
4
"
20
'
-
0
"
STREET C.L.
30' TO
2% MIN
SLOPE
2% MIN
SLOPE
5% MIN
SLOPE
5% MIN
SLOPE
5%
M
I
N
SL
O
P
E
5%
M
I
N
SL
O
P
E
4:12
4:12
4:12
4:12
4:12
Easement
5' - 0"
12' - 0"20' - 0"18' - 0"
EX. PATIO COVER
PROPERTY LINE 50'Block/Iron Fence h= 4'-0"Block/Iron Fence h= 4'-0"
Bl
o
c
k
/
I
r
o
n
F
e
n
c
e
h
=
4
'
-0"
Bl
o
c
k
/
I
r
o
n
F
e
n
c
e
h
=
4
'
-0"
Bl
o
c
k
/
I
r
o
n
F
e
n
c
e
h
=
4
'
-0"
Bl
o
c
k
/
I
r
o
n
F
e
n
c
e
h
=
5
'
-0"
Ir
o
n
G
a
t
e
h
=
5
'
-0"
EX. LAUNDRY
TO BE
DEMOLISH
EX. COVERED
PATIO
W/PERMIT
EX. CANOPY
REMOVABLE
Easement
E
A
N
A
H
U
R
S
T
P
L
.
NEW GAS
METER
NEW ELEC. PANEL
100 AMP
NEW ELEC. PANEL
100 AMP
Setback
9' - 7"
5' - 0"
Project number
Date
Drawn by
Checked by
E-mail:skyaaconstruction@gmail.com
THIS DESIGN AND DRAWINGS, ARE
COPYRIGHT PROTECTED AND ARE
THE EXCLUSIVE PROPERTY OF AA SKY
CONSTRUCTION INC., THEY SHALL BE
NO USED, MODIFIED DUPLICATED IN
WHOLE OR IN ANY MANNER, NOR
ASSIGNED TO A THIRD PARTY WITHOUT
THE WRITTEN AUTHORIZATION
OF AA SKY CONSTRUCTION INC.
APPROVAL STAMP
OWNER
CONTACT PERSON
DESIGNER
AA SKY CONSTRUCTION INC.
2074 SILVERADO ST.
SAN MARCOS CA 92078
LIC#1061749
OFFICE 858 888 3752
CELL 760 845 7697
RAFAEL G LUJANO
E-MAIL: SKYAACONSTRUCTION@GMAIL.COM
CONSULTANTS
01-A-01
EXISTING SITE PLAN &
EXISTING FLOOR
PLAN-MAIN HOUSE
0001
940 E ANAHURST PL,
STA. ANA, CA 92707
02-28-2024
Lucas
-
EX. 400 SQ.FT.
GARAGE+ NEW 280
SQ.FT. TO BE A 680
SQ.FT. ADU
RAFAEL LUJANO
2201 HALLADAY ST. STA. ANA, CA 92707
skyaaconstruction@gmail.com
+17608457697
RAFAEL LUJANO
2201 HALLADAY ST. STA. ANA, CA 92707
skyaaconstruction@gmail.com
+17608457697
1/4" = 1'-0"
Existing Floor Plan Main House2
1/8" = 1'-0"
Existing Site Plan1
No. Description Date
1 Revisión 1 Fecha 1
940 E Anahurst Pl & 2201
S Halladay11/25/2024
14
'
-
5
"
EX. WOOD
SIDING
EX. WOOD
SIDING
EX. STUCCO EX. STUCCO
13
'
-
1
0
"
14
'
-
5
"
EX. STUCCO EX. STUCCO EX. STUCCO
13
'
-
1
0
"
14
'
-
5
"
EX. WOOD
SIDING
EX. STUCCO
EX. STUCCO EX. STUCCO
EX. STUCCO
13
'
-
1
0
"
14
'
-
5
"
EX. STUCCO EX. STUCCO EX. STUCCO EX. STUCCO
EX. ROOF FRAMING AND
FINISHES TO REMAIN
2%
S
l
o
p
e
4:12
4:12
4:
1
2
4:
1
2
4:12
4:12
2%
S
l
o
p
e
28' - 6"
5' - 0"
1'
-
0
"
16' - 0"
15
'
-
0
"
11' - 3"
6'
-
1
1
"
N
PATIO COVER
53
'
-
6
"
1' - 0"
21' - 1"
12
'
-
0
"
4' - 0"
6'
-
7
"
4:
1
2
4:12
4:
1
2
4:124:12
4:
1
2
4:12
4:12
4:12
4:
1
2
4:
1
2
4:12
4'
-
0
"
14
'
-
0
"
7'
-
0
"
3' - 11"
4:12
4:
1
2
4:12
4:
1
2
Project number
Date
Drawn by
Checked by
E-mail:skyaaconstruction@gmail.com
THIS DESIGN AND DRAWINGS, ARE
COPYRIGHT PROTECTED AND ARE
THE EXCLUSIVE PROPERTY OF AA SKY
CONSTRUCTION INC., THEY SHALL BE
NO USED, MODIFIED DUPLICATED IN
WHOLE OR IN ANY MANNER, NOR
ASSIGNED TO A THIRD PARTY WITHOUT
THE WRITTEN AUTHORIZATION
OF AA SKY CONSTRUCTION INC.
APPROVAL STAMP
OWNER
CONTACT PERSON
DESIGNER
AA SKY CONSTRUCTION INC.
2074 SILVERADO ST.
SAN MARCOS CA 92078
LIC#1061749
OFFICE 858 888 3752
CELL 760 845 7697
RAFAEL G LUJANO
E-MAIL: SKYAACONSTRUCTION@GMAIL.COM
CONSULTANTS
01-A-02
EXISTING ROOF PLAN-MAIN
HOUSE & EXISTING
ELEVATIONS-MAIN HOUSE
0001
940 E ANAHURST PL,
STA. ANA, CA 92707
02-28-2024
Lucas
-
EX. 400 SQ.FT.
GARAGE+ NEW 280
SQ.FT. TO BE A 680
SQ.FT. ADU
RAFAEL LUJANO
2201 HALLADAY ST. STA. ANA, CA 92707
skyaaconstruction@gmail.com
+17608457697
RAFAEL LUJANO
2201 HALLADAY ST. STA. ANA, CA 92707
skyaaconstruction@gmail.com
+17608457697
1/4" = 1'-0"
West Elevation Main House2
1/4" = 1'-0"
North Elevation Main House5
1/4" = 1'-0"
South Elevation Main House3
1/4" = 1'-0"
East Elevation Main House4
1/4" = 1'-0"
Existing Roof Main House1
No. Description Date
940 E Anahurst Pl & 2201
S Halladay11/25/2024
Ex. Garage
N
Ex. Garage
Door to be
removed
SAW CUT EXISTING
CONCRETE 12" WIDE
BREAK AND DEMO
20' - 0"
20
'
-
0
"
20' - 0"
20
'
-
0
"
EX. HIP ROOF FRAMING
TO REMAIN
4:
1
2
4:
1
2
4:124:12
22' - 0"
22
'
-
0
"
1' - 0"
1'
-
0
"
1' - 0"
1'
-
0
"
N.Landing
3' x 4'
5
01-A-05
6
01-A-05
N
01-A-05
3
01-A-05201-A-05 4
01-A-05
1
Landing 7 3/4"
max. below
threshold
Bedroom
Bedroom
CL
CL
Bathroom
Kitchen/Dining
Living space
W
D
15"
min
15"
min
30" MIN
ø 3' - 0"
New 22"x30"
Attic Access
A
B
B
B
C
C
D
12
3
3
6' - 5"8' - 7"
6'
-
0
"
8'
-
0
"
6'
-
0
"
12
'
-
6
"
7'
-
6
"
16' - 9"3' - 3"2' - 5"11' - 7"
34' - 0"
10
'
-
3
"
9'
-
1
0
"
13' - 7"6' - 5"2' - 5"11' - 7"
20
'
-
0
"
Mini Split condenser
W.H.
6'
-
5
"
4
1
01-A-04
Tempered
Glass
Tempered
Glass
EG
R
E
S
S
W
I
N
D
O
W
EG
R
E
S
S
W
I
N
D
O
W
SPACE MIN. 2.5' X 2.5' X 7' TALL
FOR HPWH
EX. WALL TO REMAIN
EX. WALL TO BE DEMO
WALL SCHEDULE
NEW WALL
1-HR RATED/ SOUND
RATED (STC-50)
6'
-
8
"
2
2'-0"W x 2'-0"H SLIDING WINDOW VINY. YES
MARK SIZE TYPE FRAME
WINDOW SCHEDULE
NOTES:
1.BEDROOM EGRESS WINDOWS HAVE A MINIMUM CLEAR OPENING AREA OF 5.7 sf.
ABOVE THE GRADE FLOOR AND 5 SQ.FT. ON THE GRADE FLOOR, A MIN. NET HEIGHT OF 24"
AND MIN. NET WIDTH OF 20", AND SILL HEIGHT NOT MORE THAN 44" MAX. ABOVE FINISH
FLOOR.
2.THE NFRC TEMPORARY LABEL DISPLAYED ON WINDOWS AND SKYLIGHTS (INCL.
TUBULAR) MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED.
3.SHOWER AND TUB ENCLOSURES SHALL BE TEMPERED (CBC 2406.4) WINDOWS AT
SHOWERS AND TUBS SHALL BE TEMPERED.
F.F.
4'-0"W x 3'-0"H SLIDING WINDOW VINY. YES
SCREEN
1
2
QTY.
1
1
2' - 0"
2'
-
0
"
1
4' - 0"
3'
-
0
"
4'
-
0
"
4' - 0"
3
2 3 4'-0"W x 4'-0"H SLIDING WINDOW VINY. YES
6'-0"W x 4'-0"H SLIDING WINDOW VINY. YES41
6' - 0"
4
TEMPERED GLASS
TEMPERED GLASS
U-FACTOR SHGC
0.29 0.22
0.29 0.22
0.29 0.22
0.29 0.22
A B
A 3'-0" W X 6'-8" H 1 3/8" EXT. SOLID CORE DOOR WOOD WOOD
B 2'-8" W X 6'-8" H 1 3/8" INT. HOLLOW CORE DOOR WOOD WOOD
MARK OPENING SIZE TICK DOOR TYPE SCREEN FRAME
DOOR SCHEDULE
F.F.
QTY.
1
3
C 5'-0" W X 6'-8" H 1 3/8" DOUBLE SLIDING CLOSET DOOR WOOD WOOD2
C
6'
-
8
"
3' - 0"
D
D1 5'-3" W X 6'-8" H 1 3/8"DOUBLE FOLDING DOOR WOOD WOOD
5' - 0"2' - 8"5' - 3"
EX. HIP ROOF FRAMING
TO REMAIN
4:
1
2
4:
1
2
4:12
22
'
-
0
"
4:12
4:
1
2
4:
1
2
NEW HIP ROOF FRAMING TO
MATCH EXISTING
COMPOSITION SHINGLES OVER #15 FELT CLASS
"A"
(TYP) CERTAINTED OR SIMILAR ESR-1389, 3537
ICC-ES
EX. GARAGE
22' - 0"
NEW ADD
14' - 0"
36' - 0"
1'
-
0
"
1' - 0"
1'
-
0
"
1' - 0"
4:
1
2
4:
1
2
ALL SHINGLES TO MATCH THE
MAIN HOUSE
2
01-A-04
2
01-A-04
SEE ATTIC VENT CALCULATION VENT FOR ADD
PROVIDE 1 SQ. IN. OF VENTILATION PER 150 SQ. IN. OF ATTIC SPACE.
PROVIDE THAT 50% OF THE REQ. VENTILATION AREA IS PROVIDED BY
VENTILATORS IN THE UPPER PORTION OF THE ATTIC, (HIGH VENTING) AT 3'-0"
ABOVE EAVE VENT WITH THE BALANCE BEING PROVIDED BY EAVE VENTS,
(LOW VENTING) PER I.R.C. R806, (U.B.C. 1505.3).
ATTIC VENT CALCULATION ZONE
VENTILATION REQUIRED:
SQ. FT. / 150 =SQ. FT.2300ATTIC AREA
X 144 =SQ. IN.288
VENTILATION PROVIDED:
72 SQ. IN. EA. =410
SQ. IN.0
SQ. IN.O HAGIN
147 SQ. IN. EA. =-GABLE LOUVER VENT
TOTAL VENTILATION PROVIDED:SQ. IN.288
Project number
Date
Drawn by
Checked by
E-mail:skyaaconstruction@gmail.com
THIS DESIGN AND DRAWINGS, ARE
COPYRIGHT PROTECTED AND ARE
THE EXCLUSIVE PROPERTY OF AA SKY
CONSTRUCTION INC., THEY SHALL BE
NO USED, MODIFIED DUPLICATED IN
WHOLE OR IN ANY MANNER, NOR
ASSIGNED TO A THIRD PARTY WITHOUT
THE WRITTEN AUTHORIZATION
OF AA SKY CONSTRUCTION INC.
APPROVAL STAMP
OWNER
CONTACT PERSON
DESIGNER
AA SKY CONSTRUCTION INC.
2074 SILVERADO ST.
SAN MARCOS CA 92078
LIC#1061749
OFFICE 858 888 3752
CELL 760 845 7697
RAFAEL G LUJANO
E-MAIL: SKYAACONSTRUCTION@GMAIL.COM
CONSULTANTS
01-A-03
EXISTING FLOOR&ROOF
PLAN, PROPOSED
FLOOR&ROOF PLAN
0001
940 E ANAHURST PL.
STA. ANA, CA 92707
05-20-2024
Autor
Verificador
EX. 400 SQ.FT.
GARAGE+ NEW 280
SQ.FT. TO BE A 680
SQ.FT. ADU
RAFAEL LUJANO
RAFAEL LUJANO
2201 HALLADAY ST. STA. ANA, CA 92707
skyaaconstruction@gmail.com
+17608457697
ARCHITECTURAL NOTES
1.PROVIDE 72" HIGH NON ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED
SHATTER RESISTANT MATERIALS FOR SHOWER ENCLOSURE. MATERIALS OTHER THAN
STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT.
2.SIZE OF SHOWER STALL TO COMPLY WITH CPC 412.7, 1024 SQ. IN. MINIMUM INTERIOR
AND ENCOMPASSING 30" CIRCLE. DOOR SHALL SWING TO THE OUTSIDE.
3.LOW FLOW TOILETS (1.28 GALLON/FLUSH) -SHOWERHEADS (1.8 GPM @ 80 PSI)
-LAVATORY FAUCETS (1.2 GPM @ 60 PSI)
4.PROVIDE INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE
THERMOSTATIC MIXING VALVE TYPE FOR SHOWERS AND TUB SHOWERS.
5.PROVIDE WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MINIMUM OF
4" ABOVE THE EARTH OR 2" ABOVE PAVED AREAS.
6.DUCTS SHALL BE SIZED PER CHAPTER 6 OF THE MECHANICAL CODE.
7.CLOTHES DRYER MOISTURE EXHAUST DUCT IS LIMITED TO 14 FEET WITH 2 ELBOWS
FROM THE CLOTHES DRYER TO POINT OF TERMINATION REDUCE THIS LENGTH BY 2 FEET
FOR EVERY ELBOW IN EXCESS OF 2.
8.UNIT SKYLIGHTS SHALL BE LABELED BY L.A CITY APPROVED LABELING AGENCY.SUCH
LABEL SHALL STATE THE APPROVED LABELING AGENCY NAME, PRODUCT DESIGNATION AND
PERFORMANCE GRADE RATING.
10. PROVIDE ULTRA LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING
SHOWER HEADS AND TOILETS MUST BE UPDATED FOR LOW WATER CONSUMPTION.
11. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE FOOT CLEAR AND UNOBSTRUCTED
ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL BOXES,
TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE
LOCATION OF THE HOOK UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY
POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO
COMPLY MAY CAUSE CONSTRUCTION DELAYS AND OR ADDITIONAL EXPENSES.
12. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE
ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE
EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING.
13. NEW OR REPLACEMENT WATER HEATERS SHALL BE STRAPPED TO THE WALL IN TWO
PLACES. ONE IN THE UPPER 1/3 OF THE TANK AND ONE IN THE LOWER 1/3 OF THE TANK. THE
LOWER POINT SHALL BE A MINIMUM OF 4" ABOVE THE CONTROLS.(P.C.510.5) LOW IN EXCESS
OF 2.
14.PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR
TO AN APPROVED SEWAGE DISPOSAL SYSTEM (R306.3).
15. KITCHEN SINK LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND
WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND
CONNECTED TO AN APPROVED WATER SUPPLY (R306.4).
16. BATHTUB AND SHOWER FLOORS, WALL ABOVE BATHTUBS WITH A SHOWERHEAD, AND
SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH
WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6' ABOVE THE FLOOR
(R307.2).
17. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH
NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION
R303.1 OR SHALL BR PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN
AVERAGE ILLUMINATION OF 6' CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30"
ABOVE THE FLOOR LEVEL. (R303.1)
18. A COPY OF THE EVALUATION REPORT AND/ OR CONDITIONS OF LISTING SHALL BE
MADE AVAILABLE AT THE JOB SITE.
19. HEATER SHALL BE CAPABLE OF MAINTAINING A MINIMUM ROOM TEMP' OF 68°F AT A
POINT 3' ABOVE THE FLOOR AND 2' FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE
DESIGN TEMPERATURE.
20.PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE
PROVIDED IN THE LOCATIONS SPECIFIED PER SECTION R317.1 BY THE USE OF NATURALLY
DURABLE WOOD OR WOOD THAT IS PRESERVATIVE TREATED IN ACCORDANCE WITH AWPA
U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE.PRESERVATIVES SHALL BE
LISTED IN SECTION 4 OF AWPA U1.
21. PROVIDE ANTI-GRAFFITI FINISH WITHIN THE FIRST 9 FEET,MEASURED FROM GRADE,AT
EXTERIOR WALLS AND DOORS .EXCEPTION:MAINTENANCE OF BUILDING AFFIDAVIT IS
RECORDED BY THE OWNER TO COVENANT AND AGREE WITH THE CITY OF LOS ANGELES TO
REMOVE ANY GRAFFITI WITHIN 7 DAYS OF THE GRAFFITI BEING APPLIED.(6306)
UTILITY NOTES
1 ALL BRANCH CIRCUTS SUPPLYING RECEPTACLES SHALL BE PROTECTED BY A
LISTED ARC-FAULT CIRCUIT INTERRUPTER (AFCI)
2.ALL 120-VOLT, SINGLE PAHSE 15 AND 20 AMP BRANCH CIRCUIT SUPPLYING
OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
PARLORS, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS,
LAUNDRY ROOMS OR SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED BY ANY OF
THE MEANS DESCRIBED IN 210.12 (A)(1). AT KITCHEN COUNTER SPACE, RECEPTACLES
SHALL BE INDICATED AS COMBINATION AFCDI/GFCI.
3.TAMPER RESISTANT RECEPTACLES IN ALL AREAS SPECIFIED IN SECTION 210.52
ALL 125-VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER RESISTANT
RECEPTACLES
4.NEW BOXES USED AT LUMINAIRES OR LAMPHOLDER OUTLETS IN A CEILING SHALL
BE REQUIRED TO SUPPORT A LUMINAIRIE WEIGHING A MINIMUM OF 50 LB. BOXES USED AT
LUMINARIE OUTLETS IN WALL SHALL BE DESIGNED FOR THE PURPOSE AND SHALL BE
MARKED ON THE INTERIOR INDICATING THE MAXIMUM WEIGHT OF LUMINAIRE PERMITTED,
IF OTHER THAN 50 LBS. OUTLET BOXES OR SYSTEMS USED AS THE SOLE SUPPORT OF
CEILING FANS SHALL BE LISTED AND MARKED BY THE MANUFACTURE AS SUITABLE FOR
THIS PURPOSE. (314.27 CEC)
5.ALL LEAD LUMINAIRES ARE REQUIRED TO BE CONTROLLED BY NATIONAL
ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) SSL-7A-COMPLIANT DIMMER UNLESS
THEY ARE CONTROLLED BY A VACANCY SENSOR OR AN OCCUPANCY SENSOR. THE
COMBINED USE OF NEMA SSL-7A-COMPLIANT DIMMER WITH LED LUMINAIRES CAN
ENSURE FLICKER FREE OPERATION WHEN THE LUMINAIRE IS DIMMED. (2019 RESIDENTIAL
COMPLIANCE MANUAL 6.3.1(G)
6.IN BATHROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THIS SPACES MUST BE
CONTROLLED BY AN OCCUPANT SENSOR OR A VACANCY SENSOR PROVIDING
AUTOMATIC-OFF FUNCTIONALITY. IF A OCCUPANT SENSOR IS INSTALLED, IT MUST BE
INITIALLY CONFIGURED TO MANUAL-ON OPERATION USING THE MANUAL CONTROL
REQUIRED UNDER SECTION 150.0(k)2C.
ADDITIONAL NOTES
1.PROVIDE A MINIMUM OF (2) 20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN
COUNTER TOPS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE
BALANCED. CEC 210-52(B) (2)
2.PROVIDE A MINIMUM OF (1) 20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT
SHALL HAVE NO OTCOHER OUTLETS. CEC 210-23(A).
3.A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM(S) OUTLET. SUCH CIRCUIT
SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM
CEC 210-23
4.IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE
LUMINAIRE IN EACH OF THESE SPACES MUST BE CONTROLLED BY A VACANCY SENSOR.
5.OUTDOOR LIGHTING PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING, OR
TO OTHER BUILDING ON THE SAME LOT, MUST MEET THE REQUIREMENT IN ITEM
150.0(K)3AI (ON AND OFF SWITCH) AND THE REQUIREMENTS IN EITHER ITEM 150.0(K)3AII
(PHOTOCELL AND MOTION SENSOR) OR ITEM 150.0(K)3AIII (PHOTO CONTROL AND
AUTOMATIC TIME SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR EMCS
6.ALL LIMINAIRES SHALL BE HIGH EFFICACY -PER SECTION 150.0(K)1A.
7.CIRCUIT SHALL HAVE NO OTHER OUTLETS. CEC 210-23(A).
ADDITIONAL NOTES:
1. HABITABLE SPACES SHALL HAVE CEILING HEIGHT OF NO LESS THAN 7'-6". KITCHENS,
LAUNDRY ROOM, CORRIDORS AND BATHROOMS SHALL HAVE CEILING HEIGHT NOT
LESS THAN 7'.
2. PROVIDE 1 ESCAPE WINDOW IN EACH BEDROOM MEETING ALL OF THE FOLLOWING: AN
OPENABLE AREA NOT LESS THAN 5.7 SQ.FT. MIN. CLEAR 24" HEIGHT AND 20" WIDTH
AND SILL NOT OVER 44" ABOVE FLOOR
3. SHOWER WALLS MUST BE FINISHED TO A HEIGHT OF 72" ABOVE DRAIN W/ MOISTURE
RESISTIVE TILE OR APPROVED EQUAL
4. MAX. FLOW RATE STANDARDS SET BY THE CALIFORNIA ENERGY COMMISION:
F.SHOWER HEADS: 1.8 GPM @ 80 PSI
G.LAVATORY FAUCETS: 1.2 GPM @ 60 PSI
H.KITCHEN FAUCETS: 1.8 GPM @ 60 PSI
I.WATER CLOSET: 1.28 GALLONS PER FLUSH
5. EXTERIOR WALLS WITHIN 3 FEET OF PROPERTY LINE (SPRINKLERS) OR 5 FEET OF
PROPERTY LINE (WITHOUT SPRINKLERS) REQUIRE 1-HOUR FIRE RATING FOR
EXPOSURE TO BOTH SIDES
6. PROJECTIONS: -PROHIBITED WITHIN 2 FEET OF PROPERTY LINE -1-HOUR FIRE
RATING ON THE UNDERSIDE WITHIN 3FT OF PROPERTY LINE (SPRINKLERS) -1-HOUR
FIRE RATING ON THE UNDERSIDE WITHIN 5FT OF PROPERTY LINE (WITHOUT
SPRINKLERS)
7. OPENINGS: -PROHIBITED WITHIN 3FT OF PROPERTY LINE -MAXIMUM 25% OF WALL
AREA WITHIN 5 FEET OF PROPERTY LINE (WITHOUT SPRINKLERS)
8. PENETRATIONS: -1-HOUR FIRE-RATED PENETRATIONS OF WALLS WITHIN 3FT OF
PROPERTY LINE (SPRINKLERS) -1-HOUR FIRE-RATED PENETRATIONS OF WALLS
WITHIN 5FT OF PROPERTY LINE (WITHOUT SPRINKLERS)
1/4" = 1'-0"
Existing Floor Plan 21
1/4" = 1'-0"
Existing Roof Plan 22
1/4" = 1'-0"
Proposed 1st Floor Plan3
1/4" = 1'-0"
Window Schedule ADU
1/4" = 1'-0"
Door Schedule ADU
1/4" = 1'-0"
Proposed Roof Plan4
No. Description Date
1 Revisión 1 Fecha 1
OPENING SIZE ANALYSIS
1HR FIRE RATED WALL AREA = 20' X 8' = 160 SQ.FT.
160 SQ.FT. X 25% = 40 SQ.FT.
WINDOW AREA = 4' X 4' = 16 SQ.FT.
16 SQ.FT. X 2 = 32 SQ.FT.
...OK
940 E Anahurst Pl & 2201
S Halladay11/25/2024
SDCM
LED
LED LED
SD
SD
LED LED
LED LED
W.
LED
LED
EXHAUST DUCT
MUST BE TERMINATED NOT LESS THAN 3 FT
FROM OPERABLE WINDOW/DOOR OPENINGS
EXHAUST SYSTEM
MIN. 280 CFM
RATED SOUND: NOT MORE THAN 3 SONES
EXHAUST FAN WITH
FAN SOUND LEVEL
NOT TO EXCEED 3 SONE /
SPACE MIN. 2.5' X 2.5' X 7' TALL
FOR HPWH
DEDICATED 125V 20A RECEPTACLE CONNECTED
TO THE ELECTRICAL PANEL WITH A 120/240 VOLT
3 CONDUCTOR 10 AWG COPPER BRANCH CIRCUIT.
TYPE 2
SURGE PROTECTION DEVICE
ELEC. PANEL
100 AMP
NOTE:
NEW UTILITIES FOR ADU
SWITCH ON DIMMER
SWITCH ON VACANCY SENSOR
RECESSED LED LIGHT
WET LOCATION APPROVED
RECESSED LED
WALL MOUNTED LED LIGHT FIXTURE
INT/EXT
DUPLEX OUTLET (AFCI)
GFIC DUPLEX OUTLET (GFCI & AFCI
DUPLEX @ KIT & LAU)
EXTERIOR WATER PROOF GFIC
DUPLEX OUTLET
MINI SPLIT
NEW ELECTRICAL TANKLESS
WATER HEATER (200,000 BTU)
BATHROOM EXHAUST INTAKE FAN. 50
CFM MIN. WITH HUMIDY CONTROL
SENSOR DUCTED TO TERMMINATE
OUTSIDE THE BUILDING / 280 CFM MIN
AT KITCHEN
UTILITY LEGEND
W
LED
LED
ELECTRICAL PANEL 100 A.
Project number
Date
Drawn by
Checked by
E-mail:skyaaconstruction@gmail.com
THIS DESIGN AND DRAWINGS, ARE
COPYRIGHT PROTECTED AND ARE
THE EXCLUSIVE PROPERTY OF AA SKY
CONSTRUCTION INC., THEY SHALL BE
NO USED, MODIFIED DUPLICATED IN
WHOLE OR IN ANY MANNER, NOR
ASSIGNED TO A THIRD PARTY WITHOUT
THE WRITTEN AUTHORIZATION
OF AA SKY CONSTRUCTION INC.
APPROVAL STAMP
OWNER
CONTACT PERSON
DESIGNER
AA SKY CONSTRUCTION INC.
2074 SILVERADO ST.
SAN MARCOS CA 92078
LIC#1061749
OFFICE 858 888 3752
CELL 760 845 7697
RAFAEL G LUJANO
E-MAIL: SKYAACONSTRUCTION@GMAIL.COM
CONSULTANTS
01-A-04
PROPOSED UTILITY FLOOR
PLAN / ISOMETRIC VIEW
0001
940 E ANAHURST PL.
STA. ANA, CA 92707
05-20-2024
Autor
Verificador
EX. 400 SQ.FT.
GARAGE+ NEW 280
SQ.FT. TO BE A 680
SQ.FT. ADU
RAFAEL LUJANO
RAFAEL LUJANO
2201 HALLADAY ST. STA. ANA, CA 92707
skyaaconstruction@gmail.com
+17608457697
ARCHITECTURAL NOTES
1.PROVIDE 72" HIGH NON ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED
SHATTER RESISTANT MATERIALS FOR SHOWER ENCLOSURE. MATERIALS OTHER THAN
STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT.
2.SIZE OF SHOWER STALL TO COMPLY WITH CPC 412.7, 1024 SQ. IN. MINIMUM INTERIOR
AND ENCOMPASSING 30" CIRCLE. DOOR SHALL SWING TO THE OUTSIDE.
3.LOW FLOW TOILETS (1.28 GALLON/FLUSH) - SHOWERHEADS (1.8 GPM @ 80 PSI)
-FAUCETS (1.2 GPM @ 60 PSI)
4.PROVIDE INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE
THERMOSTATIC MIXING VALVE TYPE FOR SHOWERS AND TUB SHOWERS.
5.PROVIDE WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MINIMUM OF
4" ABOVE THE EARTH OR 2" ABOVE PAVED AREAS.
6.DUCTS SHALL BE SIZED PER CHAPTER 6 OF THE MECHANICAL CODE.
7.CLOTHES DRYER MOISTURE EXHAUST DUCT IS LIMITED TO 14 FEET WITH 2 ELBOWS
FROM THE CLOTHES DRYER TO POINT OF TERMINATION REDUCE THIS LENGTH BY 2 FEET
FOR EVERY ELBOW IN EXCESS OF 2.
8.UNIT SKYLIGHTS SHALL BE LABELED BY L.A CITY APPROVED LABELING AGENCY.SUCH
LABEL SHALL STATE THE APPROVED LABELING AGENCY NAME, PRODUCT DESIGNATION AND
PERFORMANCE GRADE RATING.
10. PROVIDE ULTRA LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING
SHOWER HEADS AND TOILETS MUST BE UPDATED FOR LOW WATER CONSUMPTION.
11. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE FOOT CLEAR AND UNOBSTRUCTED
ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL BOXES,
TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE
LOCATION OF THE HOOK UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY
POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO
COMPLY MAY CAUSE CONSTRUCTION DELAYS AND OR ADDITIONAL EXPENSES.
12. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE
ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE
EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING.
13. NEW OR REPLACEMENT WATER HEATERS SHALL BE STRAPPED TO THE WALL IN TWO
PLACES. ONE IN THE UPPER 1/3 OF THE TANK AND ONE IN THE LOWER 1/3 OF THE TANK. THE
LOWER POINT SHALL BE A MINIMUM OF 4" ABOVE THE CONTROLS.(P.C.510.5) LOW IN EXCESS
OF 2.
14.PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR
TO AN APPROVED SEWAGE DISPOSAL SYSTEM (R306.3).
15. KITCHEN SINK LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND
WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND
CONNECTED TO AN APPROVED WATER SUPPLY (R306.4).
16. BATHTUB AND SHOWER FLOORS, WALL ABOVE BATHTUBS WITH A SHOWERHEAD, AND
SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH
WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6' ABOVE THE FLOOR
(R307.2).
17. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH
NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION
R303.1 OR SHALL BR PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN
AVERAGE ILLUMINATION OF 6' CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30"
ABOVE THE FLOOR LEVEL. (R303.1)
18. A COPY OF THE EVALUATION REPORT AND/ OR CONDITIONS OF LISTING SHALL BE
MADE AVAILABLE AT THE JOB SITE.
19. HEATER SHALL BE CAPABLE OF MAINTAINING A MINIMUM ROOM TEMP' OF 68°F AT A
POINT 3' ABOVE THE FLOOR AND 2' FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE
DESIGN TEMPERATURE.
20.PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE
PROVIDED IN THE LOCATIONS SPECIFIED PER SECTION R317.1 BY THE USE OF NATURALLY
DURABLE WOOD OR WOOD THAT IS PRESERVATIVE TREATED IN ACCORDANCE WITH AWPA
U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE.PRESERVATIVES SHALL BE
LISTED IN SECTION 4 OF AWPA U1.
21. PROVIDE ANTI-GRAFFITI FINISH WITHIN THE FIRST 9 FEET,MEASURED FROM GRADE,AT
EXTERIOR WALLS AND DOORS .EXCEPTION:MAINTENANCE OF BUILDING AFFIDAVIT IS
RECORDED BY THE OWNER TO COVENANT AND AGREE WITH THE CITY OF LOS ANGELES TO
REMOVE ANY GRAFFITI WITHIN 7 DAYS OF THE GRAFFITI BEING APPLIED.(6306)
UTILITY NOTES
1 ALL BRANCH CIRCUTS SUPPLYING RECEPTACLES SHALL BE PROTECTED BY A
LISTED ARC-FAULT CIRCUIT INTERRUPTER (AFCI)
2.ALL 120-VOLT, SINGLE PAHSE 15 AND 20 AMP BRANCH CIRCUIT SUPPLYING
OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
PARLORS, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS,
LAUNDRY ROOMS OR SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED BY ANY OF
THE MEANS DESCRIBED IN 210.12 (A)(1). AT KITCHEN COUNTER SPACE, RECEPTACLES
SHALL BE INDICATED AS COMBINATION AFCDI/GFCI.
3.TAMPER RESISTANT RECEPTACLES IN ALL AREAS SPECIFIED IN SECTION 210.52
ALL 125-VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER RESISTANT
RECEPTACLES
4.NEW BOXES USED AT LUMINAIRES OR LAMPHOLDER OUTLETS IN A CEILING SHALL
BE REQUIRED TO SUPPORT A LUMINAIRIE WEIGHING A MINIMUM OF 50 LB. BOXES USED AT
LUMINARIE OUTLETS IN WALL SHALL BE DESIGNED FOR THE PURPOSE AND SHALL BE
MARKED ON THE INTERIOR INDICATING THE MAXIMUM WEIGHT OF LUMINAIRE PERMITTED,
IF OTHER THAN 50 LBS. OUTLET BOXES OR SYSTEMS USED AS THE SOLE SUPPORT OF
CEILING FANS SHALL BE LISTED AND MARKED BY THE MANUFACTURE AS SUITABLE FOR
THIS PURPOSE. (314.27 CEC)
5.ALL LEAD LUMINAIRES ARE REQUIRED TO BE CONTROLLED BY NATIONAL
ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) SSL-7A-COMPLIANT DIMMER UNLESS
THEY ARE CONTROLLED BY A VACANCY SENSOR OR AN OCCUPANCY SENSOR. THE
COMBINED USE OF NEMA SSL-7A-COMPLIANT DIMMER WITH LED LUMINAIRES CAN
ENSURE FLICKER FREE OPERATION WHEN THE LUMINAIRE IS DIMMED. (2019 RESIDENTIAL
COMPLIANCE MANUAL 6.3.1(G)
6.IN BATHROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THIS SPACES MUST BE
CONTROLLED BY AN OCCUPANT SENSOR OR A VACANCY SENSOR PROVIDING
AUTOMATIC-OFF FUNCTIONALITY. IF A OCCUPANT SENSOR IS INSTALLED, IT MUST BE
INITIALLY CONFIGURED TO MANUAL-ON OPERATION USING THE MANUAL CONTROL
REQUIRED UNDER SECTION 150.0(k)2C.
ADDITIONAL NOTES
1.PROVIDE A MINIMUM OF (2) 20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN
COUNTER TOPS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE
BALANCED. CEC 210-52(B) (2)
2.PROVIDE A MINIMUM OF (1) 20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT
SHALL HAVE NO OTCOHER OUTLETS. CEC 210-23(A).
3.A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM(S) OUTLET. SUCH CIRCUIT
SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM
CEC 210-23
4.IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE
LUMINAIRE IN EACH OF THESE SPACES MUST BE CONTROLLED BY A VACANCY SENSOR.
5.OUTDOOR LIGHTING PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING, OR
TO OTHER BUILDING ON THE SAME LOT, MUST MEET THE REQUIREMENT IN ITEM
150.0(K)3AI (ON AND OFF SWITCH) AND THE REQUIREMENTS IN EITHER ITEM 150.0(K)3AII
(PHOTOCELL AND MOTION SENSOR) OR ITEM 150.0(K)3AIII (PHOTO CONTROL AND
AUTOMATIC TIME SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR EMCS
6.ALL LIMINAIRES SHALL BE HIGH EFFICACY -PER SECTION 150.0(K)1A.
7.CIRCUIT SHALL HAVE NO OTHER OUTLETS. CEC 210-23(A).
1/4" = 1'-0"
Utility 1st Floor Plan (For reference only)2
Isometric View ADU4
INDOOR LIGHTING CONTROLS
A) ADDS AUTO-OFF CONTROLS FOR LIGHTING IN DRAWERS AND CABINETS.
B) UNDERSHELF, DISPLAY CABINETS, SWITCHED OUTLETS CONTROLLED
SEPARATE FROM CEILING LIGHTING.
C) LIGHTING IN HABITABLE SPACES SHALL HAVE ACCESSIBLE WALL-
MOUNTED DIMMING CONTROLS.
No. Description Date
1 Revisión 1 Fecha 1
1 1HR RATED WALL -2 1HR RATED -UNDER EAVE
.
AIR QUALITY FAN
45 CFM
WHERE WHOLE HOUSE FANS ARE USED IN BATHROOM
AREAS, THE FAN MUST RUN CONTINUOUSLY AND
SHALL NOT BE TIED TO A HUMIDITY CONTROL
SENSOR.
TYPICAL DETAIL / DRYER DUCT
UTILITY REQUIREMENTS
-ENVIRONMENTAL AIR DUCTS SHALL TERMINATE MIN. 3 FEET FROM PROPERTY LINE OR OPENINGS INTO BUILDING, AND 10 FEET FROM A
FORCED AIR INLET. (CMC 502.2.1)
-MECHANICAL EQUIPMENT SHALL BE INSTALLED PER THE MANUFACTURE’S INSTALLATION INSTRUCTIONS. (CMC 303.1)
-DOMESTIC RANGE VENTS TO BE SMOOTH METALLIC INTERIOR SURFACE. (CMC 504.3)
-SUPPLY AND RETURN AIR DUCTS TO BE INSULATED AT A MINIMUM OF R-6. (CAL ENERGY CODE TABLE 150.1-A.)
-ALL HOSE BIBBS SHALL HAVE VACUUM BREAKERS. (CPC 603.5.7)
ADDITIONAL NOTES:
1. HABITABLE SPACES SHALL HAVE CEILING HEIGHT OF NO LESS THAN 7'-6". KITCHENS,
LAUNDRY ROOM, CORRIDORS AND BATHROOMS SHALL HAVE CEILING HEIGHT NOT
LESS THAN 7'.
2. PROVIDE 1 ESCAPE WINDOW IN EACH BEDROOM MEETING ALL OF THE FOLLOWING: AN
OPENABLE AREA NOT LESS THAN 5.7 SQ.FT. MIN. CLEAR 24" HEIGHT AND 20" WIDTH
AND SILL NOT OVER 44" ABOVE FLOOR
3. SHOWER WALLS MUST BE FINISHED TO A HEIGHT OF 72" ABOVE DRAIN W/ MOISTURE
RESISTIVE TILE OR APPROVED EQUAL
4. MAX. FLOW RATE STANDARDS SET BY THE CALIFORNIA ENERGY COMMISION:
F.SHOWER HEADS: 1.8 GPM @ 80 PSI
G.LAVATORY FAUCETS: 1.2 GPM @ 60 PSI
H.KITCHEN FAUCETS: 1.8 GPM @ 60 PSI
I.WATER CLOSET: 1.28 GALLONS PER FLUSH
5. EXTERIOR WALLS WITHIN 3 FEET OF PROPERTY LINE (SPRINKLERS) OR 5 FEET OF
PROPERTY LINE (WITHOUT SPRINKLERS) REQUIRE 1-HOUR FIRE RATING FOR
EXPOSURE TO BOTH SIDES
6. PROJECTIONS: -PROHIBITED WITHIN 2 FEET OF PROPERTY LINE -1-HOUR FIRE
RATING ON THE UNDERSIDE WITHIN 3FT OF PROPERTY LINE (SPRINKLERS) -1-HOUR
FIRE RATING ON THE UNDERSIDE WITHIN 5FT OF PROPERTY LINE (WITHOUT
SPRINKLERS)
7. OPENINGS: -PROHIBITED WITHIN 3FT OF PROPERTY LINE -MAXIMUM 25% OF WALL
AREA WITHIN 5 FEET OF PROPERTY LINE (WITHOUT SPRINKLERS)
8. PENETRATIONS: -1-HOUR FIRE-RATED PENETRATIONS OF WALLS WITHIN 3FT OF
PROPERTY LINE (SPRINKLERS) -1-HOUR FIRE-RATED PENETRATIONS OF WALLS
WITHIN 5FT OF PROPERTY LINE (WITHOUT SPRINKLERS)
940 E Anahurst Pl & 2201
S Halladay11/25/2024
A-9
A-5
A-1
A-10
A-2
A-6
4'
-
6
"
7'
-
9
"
0'
-
6
"
12
'
-
9
"
A-7
A-8
3 3
A-7
A-1
A-10
A-2
4'
-
6
"
7'
-
9
"
0'
-
6
"
12
'
-
9
"
A-6
OPENING SIZE ANALYSIS
1HR FIRE RATED WALL AREA = 20' X 8' = 160 SQ.FT.
160 SQ.FT. X 25% = 40 SQ.FT.
WINDOW AREA = 4' X 4' = 16 SQ.FT.
16 SQ.FT. X 2 = 32 SQ.FT.
...OK
1 2
A-9
A-15
A-1
A-10
A-2
A-5A-6
0'
-
6
"
7'
-
9
"
4'
-
6
"
12
'
-
9
"
A
A-9
A-15
A-7
A-1
A-10
A-2
A-5
4'
-
6
"
7'
-
9
"
0'
-
6
"
12
'
-
9
"
A-6
4 A-8
1
2
3
4
5
7
9
10
13
15
14
Living space
Kitchen/Dining
I
02-S5.0
I
02-S5.0
I
02-S3.0
26
1
7
10
14
2
3
4
5
6
9
11
13
15
4'
-
2
"
8'
-
1
"
0'
-
6
"
12
'
-
9
"
Living space
CL BedroomVI
02-S3.0
VIII
02-S3.0
IX
02-S5.0
VII
02-S5.0
II
02-S5.0
26
Project number
Date
Drawn by
Checked by
E-mail:skyaaconstruction@gmail.com
THIS DESIGN AND DRAWINGS, ARE
COPYRIGHT PROTECTED AND ARE
THE EXCLUSIVE PROPERTY OF AA SKY
CONSTRUCTION INC., THEY SHALL BE
NO USED, MODIFIED DUPLICATED IN
WHOLE OR IN ANY MANNER, NOR
ASSIGNED TO A THIRD PARTY WITHOUT
THE WRITTEN AUTHORIZATION
OF AA SKY CONSTRUCTION INC.
APPROVAL STAMP
OWNER
CONTACT PERSON
DESIGNER
AA SKY CONSTRUCTION INC.
2074 SILVERADO ST.
SAN MARCOS CA 92078
LIC#1061749
OFFICE 858 888 3752
CELL 760 845 7697
RAFAEL G LUJANO
E-MAIL: SKYAACONSTRUCTION@GMAIL.COM
CONSULTANTS
01-A-05
ELEVATIONS & SECTIONS
0001
940 E ANAHURST PL.
STA. ANA, CA 92707
05-20-2024
Autor
Verificador
EX. 400 SQ.FT.
GARAGE+ NEW 280
SQ.FT. TO BE A 680
SQ.FT. ADU
RAFAEL LUJANO
RAFAEL LUJANO
2201 HALLADAY ST. STA. ANA, CA 92707
skyaaconstruction@gmail.com
+17608457697
UTILITY NOTES
1 ALL BRANCH CIRCUTS SUPPLYING RECEPTACLES SHALL BE PROTECTED BY A
LISTED ARC-FAULT CIRCUIT INTERRUPTER (AFCI)
2.ALL 120-VOLT, SINGLE PAHSE 15 AND 20 AMP BRANCH CIRCUIT SUPPLYING
OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
PARLORS, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS,
LAUNDRY ROOMS OR SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED BY ANY OF
THE MEANS DESCRIBED IN 210.12 (A)(1). AT KITCHEN COUNTER SPACE, RECEPTACLES
SHALL BE INDICATED AS COMBINATION AFCDI/GFCI.
3.TAMPER RESISTANT RECEPTACLES IN ALL AREAS SPECIFIED IN SECTION 210.52
ALL 125-VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER RESISTANT
RECEPTACLES
4.NEW BOXES USED AT LUMINAIRES OR LAMPHOLDER OUTLETS IN A CEILING SHALL
BE REQUIRED TO SUPPORT A LUMINAIRIE WEIGHING A MINIMUM OF 50 LB. BOXES USED AT
LUMINARIE OUTLETS IN WALL SHALL BE DESIGNED FOR THE PURPOSE AND SHALL BE
MARKED ON THE INTERIOR INDICATING THE MAXIMUM WEIGHT OF LUMINAIRE PERMITTED,
IF OTHER THAN 50 LBS. OUTLET BOXES OR SYSTEMS USED AS THE SOLE SUPPORT OF
CEILING FANS SHALL BE LISTED AND MARKED BY THE MANUFACTURE AS SUITABLE FOR
THIS PURPOSE. (314.27 CEC)
5.ALL LEAD LUMINAIRES ARE REQUIRED TO BE CONTROLLED BY NATIONAL
ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) SSL-7A-COMPLIANT DIMMER UNLESS
THEY ARE CONTROLLED BY A VACANCY SENSOR OR AN OCCUPANCY SENSOR. THE
COMBINED USE OF NEMA SSL-7A-COMPLIANT DIMMER WITH LED LUMINAIRES CAN
ENSURE FLICKER FREE OPERATION WHEN THE LUMINAIRE IS DIMMED. (2019 RESIDENTIAL
COMPLIANCE MANUAL 6.3.1(G)
6.IN BATHROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THIS SPACES MUST BE
CONTROLLED BY AN OCCUPANT SENSOR OR A VACANCY SENSOR PROVIDING
AUTOMATIC-OFF FUNCTIONALITY. IF A OCCUPANT SENSOR IS INSTALLED, IT MUST BE
INITIALLY CONFIGURED TO MANUAL-ON OPERATION USING THE MANUAL CONTROL
REQUIRED UNDER SECTION 150.0(k)2C.
ADDITIONAL NOTES
1.PROVIDE A MINIMUM OF (2) 20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN
COUNTER TOPS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE
BALANCED. CEC 210-52(B) (2)
2.PROVIDE A MINIMUM OF (1) 20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT
SHALL HAVE NO OTCOHER OUTLETS. CEC 210-23(A).
3.A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM(S) OUTLET. SUCH CIRCUIT
SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM
CEC 210-23
4.IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE
LUMINAIRE IN EACH OF THESE SPACES MUST BE CONTROLLED BY A VACANCY SENSOR.
5.OUTDOOR LIGHTING PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING, OR
TO OTHER BUILDING ON THE SAME LOT, MUST MEET THE REQUIREMENT IN ITEM
150.0(K)3AI (ON AND OFF SWITCH) AND THE REQUIREMENTS IN EITHER ITEM 150.0(K)3AII
(PHOTOCELL AND MOTION SENSOR) OR ITEM 150.0(K)3AIII (PHOTO CONTROL AND
AUTOMATIC TIME SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR EMCS
6.ALL LIMINAIRES SHALL BE HIGH EFFICACY -PER SECTION 150.0(K)1A.
7.CIRCUIT SHALL HAVE NO OTHER OUTLETS. CEC 210-23(A).
1/4" = 1'-0"
West Elevation ADU1 1/4" = 1'-0"
South Elevation ADU2
1/4" = 1'-0"
East Elevation ADU3 1/4" = 1'-0"
North Elevation ADU4
1/4" = 1'-0"
Section A-ADU5
1/4" = 1'-0"
Section B-ADU6
Elevation Keynotes ADU
MARK Texto de nota clave
A-1 COMPOSITION SHINGLES
OVER #15 FELT CLASS "A"
A-2 FASCIA
A-5 CONCRETE SLAB
A-6 26 GA.
CORROSION-RESISTANT
WEEP SCREED
A-7 MINI SPLIT CONDENSER
(SEE T-24)
A-8 WATER HEATER (SEE T-24)
A-9 EXTERIOR WALL LAMP
A-10 EXISTING STUCCO FINISH
A-15 WEATHER PROOF
RECEPTACLE
Section Keynotes ADU
MARK DESCRIPTION
1 COMPOSITION SHINGLES OVER #15 FELT
CLASS "A" (TYP) CERTAINTED OR SIMILAR
ESR-1389, 3537 ICC-ES
2 2"x" SILL PLATE W/ 5/8" DIA ANCHOR BOLTS
3 2"X" STUD WALL @16" O.C. TYPE DOUBLAS
FIR GRADE #2 STUD MIN.
4 DOUBLE 2x TOP PLATE AT EXTERIOR &
BEARING WALLS TYPE DOUGLAS FIR GRADE
#2
5 R-15 FIBERBATT INSULATION SEE ENERGY
CALCS
6 R-30 FIBERBATT INSULATION SEE ENERGY
CALCS
7 2"x " R.R. @ 16" O.C. TYPE DOUGLAS FIR
GRADE #2
8 2"x " C.J. @ 16" O.C. TYPE DOUGLAS FIR
GRADE #2 SEE STRUCTURAL
9 4" CONC. SLAB
10 4"x " HEADER TYPE DOUGLAS FIR GRADE #1
11 2"X SOLID BLOCK W/ FRAMING ANCHOR EA.
BLOCK TYPE DOUGLAS FIR GRADE #2
13 26 GA. CORROSION- RESISTANT WEEP
SCREED
14 1/2" GYP BOARD
15 12" FOOTING
26 PIER
ALL SHINGLES TO MATCH THE MAIN
HOUSE
NOTE:
The Exterior Material of the primary dwelling is Wood Siding
NOTE:
The Exterior Material of the primary dwelling is Wood Siding
NOTE:
WINDOW TRIM TO MATCH EXISTING
No. Description Date
1 Revisión 1 Fecha 1
NEW HARD SIDING TO MATCH TO EX
R-22 FIBERBATT INSULATION SEE ENERGY CALCS
DETAIL
.
.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
Project number
Date
Drawn by
Checked by
E-mail:skyaaconstruction@gmail.com
THIS DESIGN AND DRAWINGS, ARE
COPYRIGHT PROTECTED AND ARE
THE EXCLUSIVE PROPERTY OF AA SKY
CONSTRUCTION INC., THEY SHALL BE
NO USED, MODIFIED DUPLICATED IN
WHOLE OR IN ANY MANNER, NOR
ASSIGNED TO A THIRD PARTY WITHOUT
THE WRITTEN AUTHORIZATION
OF AA SKY CONSTRUCTION INC.
APPROVAL STAMP
OWNER
CONTACT PERSON
DESIGNER
AA SKY CONSTRUCTION INC.
2074 SILVERADO ST.
SAN MARCOS CA 92078
LIC#1061749
OFFICE 858 888 3752
CELL 760 845 7697
RAFAEL G LUJANO
E-MAIL: SKYAACONSTRUCTION@GMAIL.COM
CONSULTANTS
01-A-06
PHOTOGRAPHS OF
EXISTING SITE
CONDITIONS
0001
940 E ANAHURST PL.
STA. ANA, CA 92707
05-20-2024
Autor
Verificador
EX. 400 SQ.FT.
GARAGE+ NEW 280
SQ.FT. TO BE A 680
SQ.FT. ADU
RAFAEL LUJANO
RAFAEL LUJANO
2201 HALLADAY ST. STA. ANA, CA 92707
skyaaconstruction@gmail.com
+17608457697
No. Description Date
940 E Anahurst Pl & 2201
S Halladay11/25/2024
EX. 1,661 SQ.FT. SFD
(NO SPRINKLERS)
EX
.
D
R
I
V
E
W
A
Y
AP
P
R
O
A
C
H
N
EX. LANDSCAPE
EX. WALKWAY
EX. DRIVEWAY
EX. CONCRETE
PROPERTY LINE 50'
S HALLADAY ST.
PROPERTY LINE 50'
PR
O
P
E
R
T
Y
L
I
N
E
1
3
6
'
-10
"
PR
O
P
E
R
T
Y
L
I
N
E
1
3
6
'
-10
"
EX. LANDSCAPE
EX. LANDSCAPE
2% MIN
SLOPE
2% MIN
SLOPE
2% MIN
SLOPE
2% MIN
SLOPE
5% MIN
SLOPE
GAS METER
ELEC. PANEL
Sidewalk
WATER METER
Si
d
e
w
a
l
k
400 S.F. GARAGE CONVERSION + NEW
280 S.F. TO BE TOTAL 680 S.F. ADU
STREET C.L.
30
'
T
O
2% MIN
SLOPE
2% MIN
SLOPE
5% MIN
SLOPE
5% MIN
SLOPE
5%
M
I
N
SL
O
P
E
4:12
4:
1
2
4:12
4:
1
2
4:12
4:
1
2
4:
1
2
4:
1
2
5%
M
I
N
SL
O
P
E
11
1
'
-
1
0
"
20
'
-
0
"
EA
S
E
M
E
N
T
5'
-
0
"
12' - 0"
EX. GARAGE
20' - 0"
NEW ADD
14' - 0"
4:
1
2
SETBACK
4' - 0"
29
'
-
4
"
5' EASEMENT
EX. Block/Iron Fence h= 4'-0"EX. Block/Iron Fence h= 4'-0"
EX
.
B
l
o
c
k
/
I
r
o
n
F
e
n
c
e
h
=
4
'
-0"
EX
.
B
l
o
c
k
/
I
r
o
n
F
e
n
c
e
h
=
4
'
-0"
EX
.
B
l
o
c
k
/
I
r
o
n
F
e
n
c
e
h
=
5
'
-0"
EX
.
I
r
o
n
G
a
t
e
h
=
5
'
-0"
EX. 300 SQ.FT.
COVERED PATIO
EX. 85 SQ.FT. PORCH
10' - 11"10' - 11"3' - 9"10' - 11"10' - 11"
10
'
-
0
"
10
'
-
0
"
10
'
-
0
"
10
'
-
0
"
10
'
-
0
"
10
'
-
0
"
10
'
-
0
"
10
'
-
0
"
NEW ADDRESS:
940 E ANAHURST PL. STA. ANA, CA 92707
ADDRESS:
2201 S HALLADAY ST, SANTA ANA, CA 92707
ELEC. METER
NEW ELEC.
PANEL
100AMP.
Watter and Gas
point of connection
New gas line
New electrical line
Sewer point of connection
4" pipe to main line 2% Slope
NEW TYPE 2
SURGE PROTECTION
DEVICE
NEW GAS METER
FIRE RATED WALL
Project number
Date
Drawn by
Checked by
E-mail:skyaaconstruction@gmail.com
THIS DESIGN AND DRAWINGS, ARE
COPYRIGHT PROTECTED AND ARE
THE EXCLUSIVE PROPERTY OF AA SKY
CONSTRUCTION INC., THEY SHALL BE
NO USED, MODIFIED DUPLICATED IN
WHOLE OR IN ANY MANNER, NOR
ASSIGNED TO A THIRD PARTY WITHOUT
THE WRITTEN AUTHORIZATION
OF AA SKY CONSTRUCTION INC.
APPROVAL STAMP
OWNER
CONTACT PERSON
DESIGNER
AA SKY CONSTRUCTION INC.
2074 SILVERADO ST.
SAN MARCOS CA 92078
LIC#1061749
OFFICE 858 888 3752
CELL 760 845 7697
RAFAEL G LUJANO
E-MAIL: SKYAACONSTRUCTION@GMAIL.COM
CONSULTANTS
00-G-01.1
PROPOSED SITE
0001
940 E ANAHURST PL.
STA. ANA, CA 92707
05-20-2024
Autor
Verificador
EX. 400 SQ.FT.
GARAGE+ NEW 280
SQ.FT. TO BE A 680
SQ.FT. ADU
RAFAEL LUJANO
RAFAEL LUJANO
2201 HALLADAY ST. STA. ANA, CA 92707
skyaaconstruction@gmail.com
+17608457697
Photograph of the fence.
1/8" = 1'-0"
Proposed Site Plan1
BUS ROUTE MAP Location: Warner-Halladay
Stop ID: 6767
Buses: 72
Distance: 0.1 miles Time: 3 min.
GENERAL NOTES
1. CONTRACTOR SHALL STUDY THE DRAWINGS, SPECIFICATIONS AND FIELD CONDITIONS
BEFORE COMMENCING WITH THE WORK INVOLVED. ANY DISCREPANCIES FOUND SHALL
BE REPORTED TO THE OWNER IN WRITING FOR CORRECTIONS OR CLARIFICATION.
2. PROVIDE SHORING AT ALL TIMES WHEN ALTERING VERTICAL MEMBERS. CONTRACTOR
SHALL VERIFY ACTUAL CONDITIONS AND REPORT IN WRITING TO THE ARCHITECT FOR
RESOLUTION PRIOR TO PROCEEDING WITH THE WORK.
3. THE AREA OF GLASS IN WINDOWS LIMITED TO 20% OF THE FLOOR ADDITION PLUS THE
AREA OF ANY GLASS THAT WAS ELIMINATED IN THE ORIGINAL RESIDENCE WALL AREA
WHERE THE NEW ADDITION IS ATTACHED. ALL NEW WINDOWS SHALL BE DUAL-GLAZED.
4. ALL WINDOWS ARE TO BE WEATHER STRIPPED.
5. SMOKE DETECTORS SHALL BE INSTALLED IN AREAS GIVING ACCESS TO SLEEPING
ROOMS ON OR NEAR THE CEILING, IN EACH SLEEPING ROOM (CBC 310.9.1-4).
6. ATTIC VENTILATION, EQUAL TO 1/150 OF SPACE VENTILATED, SHALL BE PROVIDED OR AS
REQUIRED FOR FORCED AIR UNIT.
7. UTILITY LINES AND ACCESSORIES FOUND AT THE SITE THAT INTERFERE WITH THE NEW
CONSTRUCTION SHALL BE RELOCATED AS NECESSARY. THE CONTRACTOR SHALL
OBTAIN ANY BUILDING PERMIT REQUIRED.
8. ALL WOOD IN CONTACT WITH CONCRETE AND FOUNDATION SILLS SHALL BE PRESSURE
TREATED.
9. PROVIDE CORROSION RESISTED WEEP SCREED AT FOUNDATION PLATE LINE WHICH
WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING. 4"
MINIMUM HEIGHT ABOVE GRADE.
10. WALLS CONTAINING 3" OR 4" DIAMETER DRAIN/WASTE/VENT PIPING SHALL BE SIZED TO
ALLOW CUTTING/NOTCHING/BORING (2 X 6 MIN.).
11. CAULK/SEAL ALL PENETRATIONS TO TOP AND BOTTOM PLATES.
12. CAULK/SEAL ALL EXTERIOR BOTTOM PLATES.
13. INSULATION : WALLS R-15 / CEILING R-30 / FLOOR R-19
14. ALL EXTERIOR FINISH MATERIAL TO MATCH EXISTING IN TYPE AND COLOR.
15. ALL NEW ELECTRICAL WIRING SHALL BE COPPER.
16. PROVIDE SEPARATE INSPECTION FOR EACH PHASE OF EXTERIOR PLASTER AS
FOLLOWS : SCRATCH COAT, BROWN COAT , COLOR COAT [ STAPLES ARE NOT
PERMITTED FOR ATTACHING WIRE ].
17. BUILDING PAPER TO BE USED # 60 FOR STUCCO THAT DOES NOT HAVE PLYWOOD
BACKING.
18. DUCTS SHALL BE SIZED PER CHAPTER 6 OF THE MECHANICAL CODE.
19. DISTANCE FROM FACE OF THE FOUNDATION TO PROPERTY LINE TO BE ZONING SETBACK
PLUS WALL FINISH THICKNESS (MINIMUM).
20. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO
SOLID WASTE MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITES OR
BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE
STREET, GUTTER OR STORM DRAIN SYSTEM.
21. THE INSULATION INSTALLER AND THE CONTRACTOR SHALL POST A SIGNED CERTIFICATE
OF COMPLIANCE IN A CONSPICUOUS LOCATION IN THE BUILDING. THIS CERTIFICATE
SHALL STATE THAT THE INSTALLATIONS AND MATERIALS CONFORM TO THE
APPROPRIATE SECTIONS OF THE CALIFORNIA ADMINISTRATIVE CODE, TITLES 20 AND 24
AND SHALL SPECIFY THE MANUFACTORE'S NAME AND MATERIAL IDENTIFICATION, THE
INSTALLED R-VALUE, AND WHEN LOOSE FILL IS INSTALLED, SHALL STATE THE MINIMUM
INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH THE MANUFACTURE'S
LABELED DENSITY FOR THE DESIRED R-VALUE.
22. ALL INTERIOR DOORS TO BE HOLLOW CORE 1 3/8" THICK U.N.O., (SEE PLAN FOR SIZE). AT
DOUBLE INTERIOR DOOR CONDITIONS PROVIDE DEADBOLT AT TOP OF INACTIVE DOOR.
23. ALL EXTERIOR FRENCH DOORS TO BE SOLID CORE 1 3/4" THICK. (SEE PLAN FOR SIZE). AT
DOUBLE FRENCH DOORS PROVIDE DEADBOLT AT TOP AND BOTTOM OF INACTIVE DOOR
W/ TEMP. GL.
24. CONTRACTOR SHALL VERIFY WITH WINDOW MANUFACTURER THAT ALL ESCAPE OR
RESCUE WINDOWS HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET, GRADE
FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 FT. THE MIN. NET
CLEAR OPENING HEIGHT SHALL BE 24". THE MINIMUM NET CLEAR OPENING WIDTH SHALL
BE 20" AND THE BOTTOM OF THE CLEAR OPENING NO GREATER THAN 44" ABOVE THE
FLOOR (C.R.C. R310.1). WINDOWS NOT MEETING THESE REQUIREMENTS SHALL BE
BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER.
25. DUCTS PENETRATING WALL OR CEILING PENETRATIONS BETWEEN GARAGE AND
DWELLING UNIT SHALL BE CONSTRUCTED OF 26 GAGE MIN. SHEET METAL AND SHALL
HAVE NO OPENING INTO GARAGE -PER SEC R302.5.2
26. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE FOOT CLEAR AND AN OBSTRUCTED
ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES.PULL
BOXES,TRANSFORMERS, VAULTS,PUMPS,VALVES,METERS,APPURTENANCE ETC,) OR THE
LOCATION OF THE HOOK UPS.
27. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES WHEATHER
OR NOT THE LINES ARE LOCATED ON THE PROPERTY.FAILURE TO COMPLY MAY CAUSE
CONSTRUCTION DELAYS AND/ OR ADDITIONAL EXPENSES
28. AN APPROVED SEISMIC GAS SHUT OFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE
ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO
THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS
PIPING.(PER ORDINANCE170.156) (INCLUDES COMMERCIAL ADDITIONS AND IT WORK
OVER $10,000) SEPARATE PLUMBING PERMIT IS REQUIRED.
29. PROVIDE ULTRA LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION.EXISTING
SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION.
30. WATER HEATER MUST BE STRAPPED TO WALL (SEC.5013 LAPC)
31. SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDEDFOR
HUMAN OCCUPANCY, UPON THE OWNER'S APPLICATION FOR A PERMIT FOR
ALTERATIONS,REPAIRS,OR ADDITIONS EXCEEDING ONE THOUSAND DOLLARS ($1,000)
(R314.6.2)
32. WHERE A PERMIT IS REQUIRED FOR ALTERATIONS,REPAIRS OR ADDITIONS EXCEEDING
ONE THOUSAND DOLLARS ($1,000) EXISTING DWELLING OR SLEEPING UNITS THAT HAVE
ATTACHED GARAGES OR FUEL BURNING APPLIANCES SHALL BE PROVIDED WITH A
CARBON MONOXIDE ALARM IN ACCORDANCE WITH SECTION R3151.CARBON MONOXIDE
ALARMS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING
UNITS FOR WHICH THE PERMIT WAS OBTAINED (R315 .2).
33. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL
LIGHT BY MEANS OF EXTERIOR GLAZED OPENING IN ACCORDANCE WITH SECTION R303.1
OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN
AVERAGE ILLUMUNATION OF 6 FOOT -CANDLES OVER THE AREA OF THE ROOM, AT A
HEIGHT OF 30 INCHES ABOVE THE FLOOR LEVEL (R303.1)
GENERAL REQUIREMENTS
1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2022 EDITION OF THE CBC,CRC,CMC,CPC,
AND CEC AS ADOPTED AND AMENDED BY THE STATE OF CALIFORNIA IN TITLE 24 CCR
AND HIS JURISDICTION.
2. SEPARATE PERMITS MAY BE REQUIRED FOR MECHANICAL,ELECTRICAL, LUMBING,
SHORING, GRADING, AND DEMOLITION.
3. ALL PROPERTY LINES,EASEMENTS,AND EXISTING BUILDINGS HAVE BEEN INDICATED ON
THIS SITE PLAN.
4. A SECURITY FENCE SHALL BE PROVIDED AROUND THE CONSTRUCTION AREA THAT
SHALL BE INTALLED PRIOR TO EXCAVATION AND OR F FOUNDATION TRENCHING.(BMC
9-1-13302.3).
5. WATER SHALL BE PROVIDED ON THE SITE AND USES TO CONTROL DUST.
6. TEMPORARY TOILET FACILITIES SHALL BE PROVIDED ON SITE. (BMC 9-1-1-3305)
7. THE FINISH GRADE SHALL SLOPE A MIN. OF 5%,OR 6",TO A POINT 10 FEETFROM BUILDING
FOUNDATION,OR TO AN APPROVED ALTERNATE METHOD OF DIVERTING WATER AWAY
FROM THE FOUNDATION. SWALES SHALL SLOPE A MINIMUM OF 2%. (CRC R401.3)
8. THE TOP OF THE EXTERIOR FOUNDATION SHALL EXTEND ABOVE THE ELEVATION OF THE
STREET GUTTER A MINIMUM 12" OR PLUS 2 % (CRC R403.1.7.3)
FIRE PROTECTION
1. AN APPROVED SMOKE ALARMS SHALL BE INSTALLED IN EACH SLEEPING ROOM AND
HALLWAY OR AREA GIVING ACCESS TO A SLEEOING ROOM, AND EACH STORY AND
BASEMENT FOR DWELLING WITH MORE THAN ONE STORY,SMOKE ALARMS SHALL BE
INTERCONNECTED SO THAT ACTUATION OF A ONE ALARM WILL ACTIVATE ALL THE
ALARMS WITHIN THE INDIVIDUAL DWELLING UNIT.IN NEW CONSTRUCTION SMOKE
ALARMS SHALL RECIEVE THEIR PRIMARY POWER SOURCE FROM THE BUILDING WIRING
AND SHALL BE EQUIPPED WITH BATTERY BACK UP AND LOW BATTERY SIGNAL (R314).
2. AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS AND
IN SLEEPING UNITS.WITHIN WHICH FEL-BURNING APPLIANCES ARE INSTALLED AND IN
DWELLING UNITS THAT HAVE ATTACHED GARAGES,CARBON MONOXIDE ALARM SHALL BE
PROVIDED OUTSIDE OF EACH SEPARATE DWELLING UNITS SLEEPING AREA IN THE
IMMEDIATE VICINITY OF THE BEDROOMS AND ON EVERY LEVEL OF A DWELLING UNIT
INCLUDING BASEMENT (R315)
NOTE:
THE APPLICANT / PROPERTY OWNER SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING UTILITY EASEMENTS AND / OR CLEARANCE ON SITE THAT MAY AFFECT THE
PROJECT.
No. Description Date
NOTE:
1% ANNUAL CHANCE FLOOD DISCHARGE CONTAINED IN STRUCTURE.
NOTE:
NEW UTILITIES FOR ADU
940 E Anahurst Pl & 2201
S Halladay11/25/2024
Structural Calculations
for
2201 HALLADAY ST.
GARAGE TO ADU
2201 HALLADAY ST.
STA. ANA, CA 92707
29-Aug-24
JOB NO. : 24-204
4 6 8 N O R T H C A M D E N D R I V E 1 3 1 E , B E V E R L Y H I L L S , C A L I F O R N I A 9 0 2 1 0
T : 3 1 0 . 6 5 8 . 1 2 2 5 W W W . E S T R U C T U R A U S A . C O M
940 E Anahurst Pl & 2201
S Halladay11/25/2024
DESIGN CRITERIA
1 Soil supporting footings is natural grade or engineered fill.
2 Soil allowable bearing pressure used in design_______________________________
3 Footing shall extend_____ minimum into undisturbed soil or_____ below finish grade
whichever is lower.
4 All concrete shall develop a minimum compressive strength of 2500 psi in 28 days.
5 Reinforcing steel shall conform to ASTM 615, Grade 60.
6 Structural steel shall conform to the following:
Wide flange shapes ASTM A992
TS shapes ASTM A500, Grade B
Pipe shapes ASTM A53 , Grade B
Other rolled shapes, Bars and plates ASTM A36
7 Structural steel shall be fabricated in a shop of an approved fabricator.
8 All welding shall be done by Certified Welders.
9 Concrete Block shall conform to ASTM C90, Grade N-1.
10 Grout shall develop 2000 psi in 28 days.
11 Mortar shall be Type S and develop 1800 psi in 28 days.
12 All lumber shall be grade marked Douglas Fir. (Grading rule No. 17)
Light Framing Construction
Joist & Planks No. 2
Beams & Stringers No. 1
Posts & Timbers No. 1
13 Glue Laminated Timbers shall be combination No. 24F-V8.
14 Plywood shall conform to PS 1-95, Structural 1.
15 All material and workmanship shall conform to the requirements of
2022 California Building Code.
ESTRUCTURA USA, INC.
ADVANCED STRUCTURAL ENGINEERING
468 North Camden Orive #131E
Beverly Hills, CA. 90210
Sheet:
Job. No:
Project:
2
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
Fb Ft Fcperp.Fc Fv E E min
CONSTRUCTION 1000 650 625 1650 180 1,500,000 550,000
NO. 2 900 575 625 1350 180 1,600,000 580,000
NO. 1 1200 825 625 1000 170 1,600,000 580,000
NO. 1 1350 675 625 925 170 1,600,000 580,000
COMBINATION 2400 1100 650 1650 265 1,800,000 930,000
NO. 24F-V8
y-dir 1450 1100 560 1650 230 1,600,000 830,000
JOIST & PLANKS
GLU-LAM BEAMS
THICKNESS
2" TO 4" THICK
2" TO 4' WIDE
2" TO 4" THICK
GRADE
THAN THICKNESS
5" & THICKER
BEAM & STRINGER
DESIGNATION
WIDTH MORE THAN
2" GREATER THAN
THAN 2" GREATER
DOUGLAS FIR-LARCH DESIGN VALUES
6" & WIDER
5x5 AND LARGER
WIDTH NOT MORE
POST & TIMBER
LIGHT FRAMING
( 1 lTHE AS OVE VALUES ARE TAKEN FROM THE NOS.
(2)USE STANDARD GRADING RULE NO. 1 7.
2018
ESTRUCTURA USA, INC.
ADVANCED STRUCTURAL ENGINEERING
468 North Camden Orive #131E
Beverly Hills, CA. 90210
Sheet:
Job. No:
Project:
3
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
Wood :Douglas-Fir/Larch Cr = 1.15 (repetitive member factor)Fv =180 psi (for Light Framing and Joists & Planks)
E = 1,500,000 psi (Const Light Framing)Fv =170 psi (for Beams & Stringers and Posts & Timbers)
E = 1,600,000 psi (#2 Joists & Planks, #1 Beams & Stringers, #1 Posts & Timbers)
FLOOR ROOF
MEMBER:SIZE:(35 PCF)PROPERTIES:BENDING STRESS:1.00 (k-ft & k)Cd =1.00 (k-ft & k)C =1.25
Nominal Grade Type B (in)D (in)PLF A(in^2)S(in^3)I(in^4)Fb(psi)CF Fb x CF Vmax Mmax Mmax(rep) Vmax Mmax Mmax(rep)
2x4 Const. LF 1.5 3.50 1.3 5.3 3.1 5.4 1000 1.00 1000 0.63 0.26 0.29 0.79 0.32 0.37
2x6 #2 JP 1.5 5.50 2.0 8.3 7.6 20.8 900 1.30 1170 0.99 0.74 0.85 1.24 0.92 1.06
2x8 #2 JP 1.5 7.25 2.6 10.9 13.1 47.6 900 1.20 1080 1.31 1.18 1.36 1.63 1.48 1.70
2x10 #2 JP 1.5 9.25 3.4 13.9 21.4 98.9 900 1.10 990 1.67 1.76 2.03 2.08 2.21 2.54
2x12 #2 JP 1.5 11.25 4.1 16.9 31.6 178.0 900 1.00 900 2.03 2.37 2.73 2.53 2.97 3.41
2x14 #2 JP 1.5 13.25 4.8 19.9 43.9 290.8 900 0.90 810 2.39 2.96 3.41 2.98 3.70 4.26
4x4 Const LF 3.5 3.50 3.0 12.3 7.1 12.5 1000 1.00 1000 1.47 0.60 0.68 1.84 0.74 0.86
4x6 #2 JP 3.5 5.50 4.7 19.3 17.6 48.5 900 1.30 1170 2.31 1.72 1.98 2.89 2.15 2.47
4x8 #2 JP 3.5 7.25 6.2 25.4 30.7 111.1 900 1.30 1170 3.05 2.99 3.44 3.81 3.74 4.30
4x10 #2 JP 3.5 9.25 7.9 32.4 49.9 230.8 900 1.20 1080 3.89 4.49 5.17 4.86 5.62 6.46
4x12 #2 JP 3.5 11.25 9.6 39.4 73.8 415.3 900 1.10 990 4.73 6.09 7.00 5.91 7.61 8.76
4x14 #2 JP 3.5 13.25 11.3 46.4 102.4 678.5 900 1.00 900 5.57 7.68 8.83 6.96 9.60
6x4 #2 JP 5.5 3.50 4.7 19.3 11.2 19.7 900 1.00 900 2.31 0.84 2.89 1.05
6x6 #1 PT 5.5 5.50 7.4 30.3 27.7 76.3 1200 1.00 1200 3.43 2.77 4.29 3.47
6x8 #1 PT 5.5 7.50 10.0 41.3 51.6 193.4 1200 1.00 1200 4.68 5.16 5.84 6.45
6x10 #1 BS 5.5 9.50 12.7 52.3 82.7 393.0 1350 1.00 1350 5.92 9.31 7.40 11.6
6x12 #1 BS 5.5 11.50 15.4 63.3 121.2 697.1 1350 1.00 1350 7.17 13.6 8.96 17.0
6x14 #1 BS 5.5 13.50 18.0 74.3 167.1 1127.7 1350 0.99 1332 8.42 18.6 10.5 23.2
11.0
ESTRUCTURA USA, INC.
ADVANCED STRUCTURAL ENGINEERING
468 North Camden Orive #131E
Beverly Hills, CA. 90210
Sheet:
Job. No:
Project:
4
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
Fv=290 psi
Fb=2900 psi
E=psi (STOCK BEAMS)Depth Factor=(12/D)^0.111
E=psi (COMMERCIAL)
b d
3.50 x 9.50
3.50 x 11.875
3.50 x 14.0
3.50 x 16.0
3.50 x 18.0
3.50 x 20.0
3.50 x 22.0
3.50 x 24.0
3.50 x 26.0
3.50 x 28.0
5.25 x 9.500
5.25 x 11.875
5.25 x 14.0
5.25 x 16.0
5.25 x 18.0
5.25 x 20.0
5.25 x 22.0
5.25 x 24.0
5.25 x 26.0
5.25 x 28.0
5.25 x 30.0
5.25 x 32.0
5.25 x 34.0
5.25 x 36.0
5.25 x 38.0
5.25 x 40.0
5.25 x 42.0
7.00 x 9.50
7.00 x 11.875
7.00 x 14.0
7.00 x 16.0
7.00 x 18.0
7.00 x 20.0
7.00 x 22.0
7.00 x 24.0
7.00 x 26.0
7.00 x 28.0
7.00 x 30.0
7.00 x 32.0
7.00 x 34.0
7.00 x 36.0
7.00 x 40.0
7.00 x 42.0
(1) MEMBERS IN BOLD ARE COMMERCIAL SPECIAL ORDER
147 686 9604
10.8
12.2
49.9
1701
149
7690
375
27.2
35.0
488
11449.0
56.0
394
457
5126
1195
2333
3106
4032
2000000
A VS
800
8.04
9.47
33.3
41.6
M
82
53 250 6.43 12.7
19.9
PARALLAM (PSL) BEAMS
M V
125%100%
I
34.0
13.53
8.04
10.04
11.84
43.7
15.9
24.8
137 592
172
224
284
73.5
84.0
105 3500
95
54.663.0 43.7
62.3
189
125.8
94.0
109.322.0
100.6
18.6
20.3
65.5
19.1
29.8
23.7
22.8
53.3
12.1
15.1
63.8
75.2
87.5
40.7
52.4
13.5
14.9
16.2
16.9
50.9
65.5
17.8
20.3
66.6
79.7
81.9
23.9
37.3
112
126
66.5
83.1
98.0
2389
3402
105
165
229
299
378
500
977
1601
504
9.64
12.1
14.2
16.2
18.3
6048
1792
2552
733
20.3
26.4
79.0
123
350
22.3
6403
24.4
12.9
16.1
18.9
21.7
24007 38.6
1201
20.1
23.7
69.9 27.1 87.4
10987.3
39.8
54.3
16.1
70.0
77.0
84.0
91.0
98.0
17.6
18.9
25.4
30.5
233
282
336
158 788 11813
116 4659424
126
79.9 25.4 99.9
24.4 113 30.5 141
95.7 27.9 120
131 33.0 164
28.4 151 35.5 189
172 38.1 215
168 896 14336 32.5 194 40.6 243
303
179 1012 17196 34.5 218 43.1
269 48.2
272
189 1134 20412 36.5 243
336
45.7
210 1400 28000 40.6 296 50.8 370
200 1264
33.8 133
221 1544 32414 42.6 325 53.3
31.8
49.7
6211 29.8 128 37.2
406
67.9
30.5
140 467 4667 27.1 107
159
168 672 8064 32.5 150 40.6 188
154 565
47.4 252
182 789 10253 35.2 175 44.0
15750 40.6 229 50.8
219
196 915 12805 37.9 201
287
48.7 323 60.9
224 1195 19115 43.3 259 54.1
43218 56.8 433 71.1
324
210 1050
363
252 1512
15.2
2000000
395 67.737333 54.1
290238 1349
27216
57.522927 46.0
541
280 1867
404
493
294 2058
ESTRUCTURA USA, INC.
ADVANCED STRUCTURAL ENGINEERING
468 North Camden Orive #131E
Beverly Hills, CA. 90210
Sheet:
Job. No:
Project:
5
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
PO
S
T
A
R
E
A
A
L
L
O
W
A
B
L
E
L
O
A
D
(
K
I
P
S
)
-
U
N
S
U
P
P
O
R
T
E
D
H
E
I
G
H
T
I
N
F
T
(
L
O
A
D
T
A
B
L
E
12
5
%
)
SI
Z
E
IN
2
6
7
8
9
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2X
4
5
.
2
5
1
.
0
1
2X
4
X
5
.
2
5
4
.
8
3
3
.
7
3
2
.
9
4
2
.
3
6
1
.
9
3
1
.
6
1
1
.
3
6
1
.
1
7
1
.
0
1
2X
4
5
.
2
5
1
.
0
6
2X
4
X
5
.
2
5
4
.
9
7
3
.
8
7
3
.
0
6
2
.
4
7
2
.
0
3
1
.
6
9
1
.
4
3
1
.
2
3
1
.
0
6
2X
6
8
.
2
5
1
.
6
7
2X
6
X
8
.
2
5
1
2
.
4
0
1
1
.
0
8
9
.
6
4
8
.
2
6
7
.
0
6
6
.
0
4
5
.
2
0
4
.
5
1
3
.
9
4
3
.
4
7
3
.
0
7
2
.
7
4
2
.
4
6
2
.
2
1
2
.
0
1
1
.
8
2
1
.
6
7
2X
8
1
0
.
8
8
2
.
1
9
2X
8
X
1
0
.
8
8
1
7
.
5
1
6
.
7
1
5
.
7
1
4
.
5
1
3
.
2
1
1
.
9
1
0
.
6
9
.
4
8
.
3
7
7
.
4
7
6
.
6
9
6
.
0
1
5
.
4
2
4
.
9
1
4
.
4
6
4
.
0
7
3
.
7
3
3X
4
8
.
7
5
4
.
6
7
3
.
5
1
2
.
7
2
2
.
1
7
1
.
7
7
3X
4
X
8
.
7
5
8
.
2
8
6
.
4
5
5
.
1
1
4
.
1
2
3
.
3
8
2
.
8
2
2
.
3
9
2
.
0
4
1
.
7
7
3X
6
1
3
.
7
5
7
.
3
2
5
.
5
0
4
.
2
7
3
.
4
1
2
.
7
8
3X
6
X
1
3
.
7
5
2
0
.
7
1
8
.
5
1
6
.
1
1
3
.
8
1
1
.
8
1
0
.
1
8
.
6
7
7
.
5
2
6
.
5
7
5
.
7
8
5
.
1
2
4
.
5
7
4
.
0
9
3
.
6
9
3
.
3
4
3
.
0
4
2
.
7
8
3X
8
1
8
.
1
3
9
.
6
0
7
.
2
4
5
.
6
2
4
.
4
9
3
.
6
6
3X
8
X
1
8
.
1
3
2
9
.
2
2
7
.
9
2
6
.
2
2
4
.
2
2
2
.
0
1
9
.
8
1
7
.
6
1
5
.
7
1
4
.
0
1
2
.
4
1
1
.
1
1
0
.
0
9
.
0
3
8
.
1
8
7
.
4
4
6
.
7
9
6
.
2
2
4X
4
1
2
.
2
5
1
1
.
6
9
.
0
3
7
.
1
5
5
.
7
6
4
.
7
3
3
.
9
5
3
.
3
4
2
.
8
6
2
.
4
8
4X
6
1
9
.
2
5
1
8
.
0
1
4
.
1
1
1
.
2
9
.
0
3
7
.
4
2
6
.
1
9
5
.
2
4
4
.
4
9
3
.
8
9
4X
6
X
1
9
.
2
5
2
8
.
9
2
5
.
8
2
2
.
5
1
9
.
3
1
6
.
5
1
4
.
1
1
2
.
1
1
0
.
5
9
.
2
0
8
.
0
9
7
.
1
7
6
.
3
9
5
.
7
3
5
.
1
7
4
.
6
8
4
.
2
6
3
.
8
9
4X
8
2
5
.
3
8
2
3
.
5
1
8
.
4
1
4
.
7
1
1
.
9
9
.
8
8
.
1
5
6
.
9
0
5
.
9
1
5
.
1
2
4X
8
X
2
5
.
3
8
4
0
.
9
3
9
.
0
3
6
.
7
3
3
.
9
3
0
.
8
2
7
.
7
2
4
.
7
2
1
.
9
1
9
.
5
1
7
.
4
1
5
.
6
1
4
.
0
1
2
.
6
1
1
.
5
1
0
.
4
9
.
5
8
.
7
1
6X
6
3
0
.
2
5
3
3
.
4
3
1
.
4
2
8
.
8
2
6
.
0
2
3
.
1
2
0
.
3
1
7
.
8
1
5
.
7
1
3
.
9
1
2
.
3
1
0
.
9
9
.
8
0
8
.
8
1
7
.
9
7
7
.
2
3
6
.
5
9
6
.
0
3
6X
8
4
1
.
2
5
4
5
.
6
4
2
.
8
3
9
.
3
3
5
.
4
3
1
.
5
2
7
.
7
2
4
.
3
2
1
.
4
1
8
.
9
1
6
.
7
1
4
.
9
1
3
.
4
1
2
.
0
1
0
.
9
9
.
9
9
.
0
8
.
2
6X
8
X
4
1
.
2
5
4
8
.
5
4
7
.
1
4
5
.
4
4
3
.
3
4
0
.
8
3
8
.
0
3
5
.
0
3
2
.
0
2
9
.
1
2
6
.
4
2
3
.
9
2
1
.
7
1
9
.
7
1
8
.
0
1
6
.
4
1
5
.
0
1
3
.
8
6X
1
0
5
2
.
2
5
5
4
.
0
5
1
.
1
4
7
.
4
4
3
.
1
3
8
.
6
3
4
.
3
3
0
.
3
2
6
.
7
2
3
.
7
2
1
.
0
1
8
.
8
1
6
.
8
1
5
.
1
1
3
.
7
1
2
.
4
1
1
.
3
1
0
.
4
6X
1
0
X
5
2
.
2
5
5
8
.
6
5
7
.
8
5
6
.
9
5
5
.
9
5
4
.
6
5
3
.
0
5
1
.
2
4
9
.
2
4
6
.
9
4
4
.
5
4
1
.
9
3
9
.
3
3
6
.
8
3
4
.
3
3
1
.
9
2
9
.
7
2
7
.
6
8X
8
5
6
.
2
5
6
6
.
4
6
4
.
7
6
2
.
6
6
0
.
0
5
6
.
8
5
3
.
3
4
9
.
4
4
5
.
4
4
1
.
5
3
7
.
8
3
4
.
4
3
1
.
2
2
8
.
5
2
6
.
0
2
3
.
8
2
1
.
8
2
0
.
0
X
I
N
D
I
C
A
T
E
S
B
R
A
C
E
D
I
N
W
E
A
K
D
I
R
E
C
T
I
O
N
LL
V
A
L
U
E
S
B
A
S
E
D
O
N
D
O
U
G
L
A
S
F
I
R
-
L
A
R
C
H
No.1GRADEConstNo. 2 No.2 No. 2
ESTRUCTURA USA, INC.
ADVANCED STRUCTURAL ENGINEERING
468 North Camden Orive #131E
Beverly Hills, CA. 90210
Sheet:
Job. No:
Project:
6
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
PO
S
T
A
R
E
A
A
L
L
O
W
A
B
L
E
L
O
A
D
(
K
I
P
S
)
-
U
N
S
U
P
P
O
R
T
E
D
H
E
I
G
H
T
I
N
F
T
(
L
O
A
D
T
A
B
L
E
16
0
%
)
SI
Z
E
IN
2
6
7
8
9
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2X
4
5
.
2
5
1
.
0
1
2X
4
X
5
.
2
5
5
.
0
3
3
.
8
3
2
.
9
9
2
.
3
9
1
.
9
5
1
.
6
3
1
.
3
7
1
.
1
7
1
.
0
1
2X
4
5
.
2
5
1
.
0
7
2X
4
X
5
.
2
5
5
.
2
2
3
.
9
9
3
.
1
3
2
.
5
1
2
.
0
5
1
.
7
1
1
.
4
4
1
.
2
3
1
.
0
7
2X
6
8
.
2
5
1
.
6
8
2X
6
X
8
.
2
5
1
4
.
5
6
1
2
.
4
8
1
0
.
4
9
8
.
7
8
7
.
3
7
6
.
2
4
5
.
3
4
4
.
6
1
4
.
0
1
3
.
5
2
3
.
1
1
2
.
7
7
2
.
4
8
2
.
2
3
2
.
0
2
1
.
8
4
1
.
6
8
2X
8
1
0
.
8
8
2
.
2
1
2X
8
X
1
0
.
8
8
2
1
.
6
2
0
.
2
1
8
.
5
1
6
.
6
1
4
.
7
1
2
.
9
1
1
.
3
9
.
9
8
.
7
1
7
.
7
1
6
.
8
7
6
.
1
4
5
.
5
3
4
.
9
9
4
.
5
3
4
.
1
3
3
.
7
8
3X
4
8
.
7
5
4
.
7
6
3
.
5
6
2
.
7
5
2
.
1
9
1
.
7
8
3X
4
X
8
.
7
5
8
.
7
0
6
.
6
6
5
.
2
2
4
.
1
8
3
.
4
2
2
.
8
5
2
.
4
0
2
.
0
6
1
.
7
8
3X
6
1
3
.
7
5
7
.
4
6
5
.
5
8
4
.
3
1
3
.
4
3
2
.
7
9
3X
6
X
1
3
.
7
5
2
4
.
3
2
0
.
8
1
7
.
5
1
4
.
6
1
2
.
3
1
0
.
4
8
.
9
0
7
.
6
8
6
.
6
8
5
.
8
6
5
.
1
8
4
.
6
1
4
.
1
3
3
.
7
2
3
.
3
7
3
.
0
6
2
.
7
9
3X
8
1
8
.
1
3
9
.
8
1
7
.
3
4
5
.
6
8
4
.
5
2
3
.
6
8
3X
8
X
1
8
.
1
3
3
6
.
1
3
3
.
7
3
0
.
8
2
7
.
6
2
4
.
4
2
1
.
4
1
8
.
8
1
6
.
5
1
4
.
5
1
2
.
9
1
1
.
4
1
0
.
2
9
.
2
1
8
.
3
2
7
.
5
5
6
.
8
8
6
.
2
9
4X
4
1
2
.
2
5
1
2
.
2
9
.
3
2
7
.
3
0
5
.
8
5
4
.
7
9
3
.
9
9
3
.
3
7
2
.
8
8
2
.
4
9
4X
6
1
9
.
2
5
1
9
.
0
1
4
.
6
1
1
.
4
9
.
1
8
7
.
5
1
6
.
2
5
5
.
2
8
4
.
5
2
3
.
9
1
4X
6
X
1
9
.
2
5
3
4
.
0
2
9
.
1
2
4
.
5
2
0
.
5
1
7
.
2
1
4
.
6
1
2
.
5
1
0
.
7
9
.
3
6
8
.
2
1
7
.
2
6
6
.
4
6
5
.
7
8
5
.
2
1
4
.
7
1
4
.
2
8
3
.
9
1
4X
8
2
5
.
3
8
2
4
.
8
1
9
.
1
1
5
.
0
1
2
.
1
9
.
9
8
.
2
3
6
.
9
6
5
.
9
5
5
.
1
5
4X
8
X
2
5
.
3
8
5
0
.
5
4
7
.
2
4
3
.
2
3
8
.
7
3
4
.
2
3
0
.
0
2
6
.
3
2
3
.
1
2
0
.
3
1
8
.
0
1
6
.
0
1
4
.
3
1
2
.
9
1
1
.
6
1
0
.
6
9
.
6
8
.
8
1
6X
6
3
0
.
2
5
4
0
.
7
3
7
.
2
3
3
.
1
2
8
.
9
2
5
.
0
2
1
.
6
1
8
.
7
1
6
.
3
1
4
.
3
1
2
.
6
1
1
.
2
9
.
9
7
8
.
9
5
8
.
0
7
7
.
3
1
6
.
6
6
6
.
0
8
6X
8
4
1
.
2
5
5
5
.
6
5
0
.
7
4
5
.
1
3
9
.
4
3
4
.
1
2
9
.
4
2
5
.
5
2
2
.
2
1
9
.
5
1
7
.
2
1
5
.
2
1
3
.
6
1
2
.
2
1
1
.
0
1
0
.
0
9
.
1
8
.
3
6X
8
X
4
1
.
2
5
6
0
.
7
5
8
.
3
5
5
.
3
5
1
.
6
4
7
.
5
4
3
.
1
3
8
.
8
3
4
.
7
3
1
.
1
2
7
.
8
2
5
.
0
2
2
.
5
2
0
.
3
1
8
.
5
1
6
.
8
1
5
.
3
1
4
.
1
6X
1
0
5
2
.
2
5
6
6
.
2
6
1
.
0
5
4
.
9
4
8
.
4
4
2
.
2
3
6
.
6
3
1
.
9
2
7
.
8
2
4
.
4
2
1
.
6
1
9
.
2
1
7
.
1
1
5
.
4
1
3
.
9
1
2
.
6
1
1
.
5
1
0
.
5
6X
1
0
X
5
2
.
2
5
7
4
.
3
7
3
.
0
7
1
.
4
6
9
.
5
6
7
.
2
6
4
.
5
6
1
.
3
5
7
.
9
5
4
.
2
5
0
.
5
4
6
.
7
4
3
.
1
3
9
.
8
3
6
.
6
3
3
.
8
3
1
.
2
2
8
.
8
8X
8
5
6
.
2
5
8
3
.
3
8
0
.
3
7
6
.
5
7
2
.
0
6
6
.
7
6
1
.
0
5
5
.
2
4
9
.
7
4
4
.
7
4
0
.
1
3
6
.
1
3
2
.
6
2
9
.
5
2
6
.
8
2
4
.
4
2
2
.
3
2
0
.
4
X
I
N
D
I
C
A
T
E
S
B
R
A
C
E
D
I
N
W
E
A
K
D
I
R
E
C
T
I
O
N
AL
L
V
A
L
U
E
S
B
A
S
E
D
O
N
D
O
U
G
L
A
S
F
I
R
-
L
A
R
C
H
No.1GRADEConstNo. 2 No.2 No. 2
ESTRUCTURA USA, INC.
ADVANCED STRUCTURAL ENGINEERING
468 North Camden Orive #131E
Beverly Hills, CA. 90210
Sheet:
Job. No:
Project:
7
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
ROOF LOADS
composite shingles 3.0 psf
re-roof 3.0 psf
1/2" plywwod 1.5 psf
rafters 2x6 at 16"2.0 psf
insulation 0.5 psf
Ceiling 3.0 psf
beams/headers 1.0 psf
MP&E/ misc.1.0 psf
D= 15.0 psf
Lr= 20.0 psf REDUCIBLE
EXTERIOR WALL LOADS
7/8" stucco 10.0 psf
1/2" plywood 1.5 psf
2x6 studs at 16"oc 1.5 psf
insulation 0.5 psf
1/2" gyp board 2.3 psf
MP&E/ misc.0.2 psf
D= 16.0 psf
INTERIOR WALL LOADS
1/2" gyp board 2.3 psf
1/2" plywood 1.5 psf
2x6 studs at 16"oc 1.5 psf
insulation 0.5 psf
1/2" gyp board 2.3 psf
MP&E/ misc.1.9 psf
D= 10.0 psf
A-DESIGN LOADS-comp. shingles
ESTRUCTURA USA, INC.
ADVANCED STRUCTURAL ENGINEERING
468 North Camden Orive #131E
Beverly Hills, CA. 90210
Sheet:
Job. No:
Project:
8
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
2x4 TA= 450 x 1.60 x 1.5 x 3.5 =kips
2x6 TA= 575 x 1.60 x 1.5 x 5.5 =kips
3x4 TA= 575 x 1.60 x 2.5 x 3.5 =kips
3x6 TA= 575 x 1.60 x 2.5 x 5.5 = kips
TYPE
2x4 6 TA= 141 x 1.60 x x 6 = 1.25 kips 1.5FT
2x4 8 TA= 141 x 1.60 x x 8 = 1.67 kips 2FT
2x4 10 TA= 141 x 1.60 x x 10 = 2.09 kips 2.5FT
2x4 12 TA= 141 x 1.60 x x 12 = 2.51 kips 3FT
2x4 14 TA= 141 x 1.60 x x 14 = 2.92 kips 3.5FT
2x4 16 TA= 141 x 1.60 x x 16 = 3.34 kips 4FT
2x4 18 TA= 141 x 1.60 x x 18 = 3.76 kips 4.5FT
2x6 20 TA= 141 x 1.60 x x 20 = 4.18 kips 5FT
2x6 22 TA= 141 x 1.60 x x 22 = 4.60 kips 5.5FT
2x6 24 TA= 141 x 1.60 x x 24 = 5.01 kips 6FT
2x6 B1 TA= 604 x 1.60 x x 6 = 5.80 kips 0.99
2x6 B2 TA= 604 x 1.60 x x 8 = 7.73 kips 1.09
3x6 B3 TA= 725 x 1.60 x x 8 = 9.28 kips 1.09
3x6 B4 TA=1208 x 1.60 x x 6 = 11.60 kips 1.19
3x6 B5 TA=1208 x 1.60 x x 8 = 15.46 kips 1.31
SPLICE LENGTH
0.93
DOUBLE TOP PLATE SPLICE
3.78
7.59
0.93
0.93
8.05
12.65
0.93
0.93
0.93
0.93
0.93
1.00
0.93
0.93
1.00
1.00
1.00
1.00
ESTRUCTURA USA, INC.
ADVANCED STRUCTURAL ENGINEERING
468 North Camden Orive #131E
Beverly Hills, CA. 90210
Sheet:
Job. No:
Project:
9
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
10
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
ROOF JOIST
Tag:RJ-1
L=11.00 ft
Uniform Loads
D (psf) L (psf) s (in) W (plf)
Shear:Vmax <Vallow OK
0.26 K 1.24 K
Flexure:Mmax <Mallow OK
0.71 k-ft 1.06 k-ft
USE:16" O.C.
Deflection:Δ =0.46 in = L/286 OK
Tag:RJ-2
L=3.00 ft
Uniform Loads
D (psf) L (psf) s (in) W (plf)
Shear:Vmax <Vallow OK
0.07 K 0.79 K
Flexure:Mmax <Mallow OK
0.05 k-ft 0.37 k-ft
USE:16" O.C.
Deflection:Δ =0.01 in = L/3630 OK
2x6 RAFTERS @
2x4 RAFTERS @
11
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
Fb= 900 psi Fv= 180 psi L/ 180 (TL) L/ 240 (LL)E psi
Tag:
L=
Uniform Loads Member:2x 10
Cd=1.25
Cr=1.15
Cf=1.10
Vd=k < VA=k OK
M=k-ft < MA=k-ft OK
DTL=in = L/OK USE:2x 10 JOIST @ 16" O.C.
DLL=in = L/OK444
46.67 1.5 9.25
b (in) d (in)
15 20 16
1600000
CEILING JOIST
CJ-1
19.25 ft
D (psf) L (psf) S (in) w (plf)
0.41
2.16 2.54
2.08
0.91
0.52
254
12
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
Tag:HB-1
Member:W
w
L = 14.14 ft
L1 = 10.00 ft
V1= 0.58 kips L= 14.14 ft V2= 1.17 kips
D (psf) L (psf) w (plf) W (kips)
Shear:Vmax <Vallow OK
1.17 K 3.80 K
Flexure:Mmax <Mallow OK
3.18 k-ft 3.74 k-ft
Deflection:Δ =0.63 in x OK
USE:4x8
4x8
13
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
Tag:B1
Member:
L = 3.67 ft
No. Members: 1
L =3.67 ft 0.19 kips 0.19 kips
A = 12.25 in²
S = 7.15 in³Shear and Moment Diagrams
I = 12.51 in⁴
E = 1,600,000 psi
Va = 1.47 kips
Ma =0.60 k-ft
CD = 1.25
CF =1.00
CV =1.00
Cr =1.00 Mmáx = 0.18 k-ft
Total Load L/n=180 Vmáx = 0.19 kips
Live Load L/n=240
Uniform Loads Shear:
D (psf) L (psf) Trib. (ft) W Vmáx = 0.19 kips
15 20 3.00 105 Vallow = 1.84 kips 10%
OK
Flexure:
Mmáx =0.18 k-ft
Σw =0.105 klf Mallow =0.74 k-ft 24%
OK
Point Loads (P1)x1 = 0.00 ft
D (psf) L (psf) Trib. 1 (ft) Trib. 2 (ft) W Deflection:
D(D+L) = 0.02 in 9%
L <L
2056 180
Σw =0.000 kips OK
Point Loads (P2)x2 = 0.00 ft D(L ONLY) =0.01 in 7%
D (psf) L (psf) Trib. 1 (ft) Trib. 2 (ft) W
L <L
3598 240
OK
Σw =0.000 kips USE:1- 4X4
4x4
𝐷=
14
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
Tag:B2 4.68 kips
Member:
L = 19.25 ft
No. Members: 1
L = 19.25 ft 2.79 kips 2.79 kips
A = 62.34 in²
S = 123.39 in³Shear and Moment Diagrams
I = 732.62 in⁴
E = 2,000,000 psi
Va = 12.05 kips
Ma =29.82 k-ft
CD = 1.25
CF =1.00
CV =1.00
Cr =1.00 Mmáx = 24.68 k-ft
Total Load L/n=180 Vmáx = 2.79 kips
Live Load L/n=240
Uniform Loads Shear:
D (psf) L (psf) Trib. (ft) W Vmáx = 2.79 kips
15 20 1.33 47 Vallow = 15.07 kips 19%
OK
Flexure:
Mmáx =24.68 k-ft
Σw =0.047 klf Mallow =37.32 k-ft 66%
OK
Point Loads (P1)x1 = 9.63 ft
D (psf) L (psf) Trib. 1 (ft) Trib. 2 (ft) W Deflection:
2005.71 2674.29 1 1 4680
D(D+L) = 0.92 in 72%
L <L
252 180
Σw =4.680 kips OK
Point Loads (P2)x2 = 0.00 ft D(L ONLY) =0.52 in 55%
D (psf) L (psf) Trib. 1 (ft) Trib. 2 (ft) W
L <L
440 240
OK
Σw =0.000 kips USE:1- 5.25X11.875 PSL
5.25x11.875 PSL
𝐷=
15
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
NOTCH ON COMPRESSION FACE AT END
B2
1.833
5.798
0.583
5.214
V 2790 lbs member type=
b=5.25 in viga Fv=psi
d 11.88 in viga Cd=
dn=4.63 in F'v=psi
e=18.00 in 'e' > 'dn', therefore use Eq.(3.4-2)slope=4 :12
support member width w=3.5 in
2018 NDS Equation 3.4-5
fv=
2b
=3 x =-49 psi <363 psi, therefore NA
2 x 5.3 x 11.88 -- 4.63 x 18
Use Eq. (3.4-2)
2018 NDS Equation 3.4-2
fv= 1.5V = 172 psi < 363 psi, therefore Satisfactory (.48)
b dn
5.50
5.21dn Rec'd=
4.63
draftrer=
11.88
psl
290
1.25
363
2790
3V
d-(d-dn)/(dn)*e
e
dn
d
16
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
HEADERS
Tag:H1
L = 3.25 ft
Uniform Loads
D (psf) L (psf) Trib. (ft)W 33%Shear:Vmax <Vallow
Roof 15 20 9.63 337 OK 0.60 K 1.84 K
Floor
Wall 16 2.00 32 66%Flexure:Mmax <Mallow
Σw =0.369 klf OK 0.49 k-ft 0.74 k-ft
28%Deflection:Δ =0.05 in = L/842
USE:OK
Tag:H2
L = 4.00 ft
Uniform Loads
D (psf) L (psf) Trib. (ft)W 40%Shear:Vmax <Vallow
Roof 15 20 9.63 337 OK 0.74 K 1.84 K
Floor
Wall 16 2.00 32 99%Flexure:Mmax <Mallow
Σw =0.369 klf OK 0.74 k-ft 0.74 k-ft
53%Deflection:Δ =0.11 in = L/452
USE:OK
Tag:H3
L = 6.00 ft
Uniform Loads
D (psf) L (psf) Trib. (ft)W 25%Shear:Vmax <Vallow
Roof 15 20 6.00 210 OK 0.73 K 2.89 K
Floor
Wall 16 2.00 32 51%Flexure:Mmax <Mallow
Σw =0.242 klf OK 1.09 k-ft 2.15 k-ft
30%Deflection:Δ =0.09 in = L/792
USE:OK
Tag:H4
L = 3.00 ft
Uniform Loads
D (psf) L (psf) Trib. (ft)W 20%Shear:Vmax <Vallow
Roof 15 20 6.00 210 OK 0.36 K 1.84 K
Floor
Wall 16 2.00 32 37%Flexure:Mmax <Mallow
Σw =0.242 klf OK 0.27 k-ft 0.74 k-ft
15%Deflection:Δ =0.02 in = L/1633
USE:OK
4x4
4x4
4x6
4x4
𝑉=𝑀=𝑊𝐿
8
=𝑀=𝑊𝐿
8
=𝑀=𝑊𝐿
8
=𝑀=𝑊𝐿
8
17
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
18
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
CONTINUOUS FOOTINGS
Tag:(E) CF-1
Uniform Loads
D (psf)L (psf) Trib. (ft)W
ROOF 15 20 10.63 372
DECK
FLOOR
WALL 16 8.00 128
Σw =499.88 plf
USE:
B =500 plf =0.33 ft
1500 plf
Tag:(N) CF-2
Uniform Loads
D (psf)L (psf) Trib. (ft)W
ROOF 15 20 10.63 372
DECK
FLOOR
WALL 16 8.00 128
Σw =499.88 plf
USE:
B =500 plf =0.33 ft
1500 plf
1'-0" WIDE FTG.
1'-0" WIDE FTG.
19
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
FOOTING CAPACITY
Tag:(E) CF-1
H1= 18 in qa= 1500 psf
H2= 8 in L= 55.50 in
D= 4 in 4.63 ft
W= 12 in A= 666 in²
4.63 ft²
Uniform Loads
D (psf) L (psf) Trib. (ft) W
Roof 15 20 10.63 372
Deck
Floor
Wall 16 8.00 128
Σw =500.05 plf
Conc. Wt. = 100 plf
Abv. Grade
Wuniforme= 600 plf
Pa= 6.94 kips
Pload= 2.78 kips
Pnet= 4.16 kips
Pnet = 4.16 kips
20
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
FOOTING CAPACITY
Tag:(N) CF-2
H1= 24 in qa= 1500 psf
H2= 8 in L= 67.50 in
D= 4 in 5.63 ft
W= 12 in A= 810 in²
5.63 ft²
Uniform Loads
D (psf) L (psf) Trib. (ft) W
Roof 15 20 9.63 337
Deck
Floor
Wall 16 8.00 128
Σw =464.88 plf
Conc. Wt. = 100 plf
Abv. Grade
Wuniforme= 565 plf
Pa= 8.44 kips
Pload= 3.18 kips
Pnet= 5.26 kips
Pnet = 5.26 kips
21
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
SPREAD FOOTINGS
Tag:F1
Loads:Pmax <Pallow OK
P (K)2.34 K 3.04 K
2.34
USE:TYPE 1.5 FOOTING
ΣP =2.34 K
Tag:F2
Loads:Pmax <Pallow OK
P (K)0.58 K 3.04 K
0.58
USE:TYPE 1.5 FOOTING
ΣP =0.58 K
Tag:F3
Loads:Pmax <Pallow OK
P (K)0.38 K 3.04 K
0.38
USE:TYPE 1.5 FOOTING
ΣP =0.38 K
Tag:F4
Loads:Pmax <Pallow OK
P (K)2.79 K 3.04 K
2.79
USE:TYPE 1.5 FOOTING
ΣP =2.79 K
22
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
Ba
r
#
Ar
e
a
(
i
n
2)
So
i
l
B
e
a
r
i
n
g
P
r
e
s
s
u
r
e
:
Mi
s
c
e
l
l
a
n
e
o
u
s
:
3
0
.
1
1
q
=
15
0
0
ps
f
co
l
u
m
n
f
o
o
t
p
r
i
n
t
=
4
in
4
0
.
2
0
qu =
q
x
1
.
6
=
24
0
0
p
s
f
st
e
e
l
s
p
a
c
i
n
g
f
a
c
t
o
r
=
10
5
0
.
3
1
(f
o
r
s
e
l
e
c
t
i
o
n
o
f
s
t
e
e
l
s
p
a
c
i
n
g
v
s
.
s
i
z
e
o
n
l
y
)
6
0
.
4
4
Ma
t
e
r
i
a
l
S
t
r
e
n
g
t
h
s
:
7
0
.
6
0
co
n
c
r
e
t
e
=
25
0
0
ps
i
No
t
e
s
:
8
0
.
7
8
fy =
60
ks
i
As
s
u
m
e
s
P
u =
1
.
6
(
D
L
+
L
L
)
9
1
.
0
0
10
1
.
2
3
11
1
.
5
6
Ma
r
k
:
Si
z
e
T
h
i
c
k
Pma
x
De
p
t
h
Mu
a
A
s
As
As m
i
n
A
s
(f
t
)
-
S
Q
.
(
i
n
)
(
k
)
(
i
n
)
Vac
t
(
k
)
V
al
l
(
k
)
OK
?
Vac
t
(
k
)
V
al
l
(
k
)
OK
?
(
k
-
i
n
)
(
i
n
)
(
R
e
q
'
d
)
(2
0
0
/
F
y)
(.
0
0
1
8
)
U
s
e
U
S
E
:
1.
5
1
2
3.
0
4
8
0
.
0
1
2
.
2
Y
2
.
7
6
5
.
3
Y
7
0
.
0
2
0
.
0
2
0
.
7
2
0
.
3
9
0
.
3
9
2
#
4
2.
0
1
2
5.
4
0
8
0
.
7
1
6
.
3
Y
6
.
5
6
5
.
3
Y
1
8
0
.
0
5
0
.
0
4
0
.
9
6
0
.
5
2
0
.
5
2
3
#
4
2.
5
1
2
8.
4
4
8
2
.
3
2
0
.
4
Y
1
1
.
3
6
5
.
3
Y
3
8
0
.
0
8
0
.
0
9
1
.
2
0
0
.
6
5
0
.
6
5
4
#
4
3.
0
1
2
12
.
2
8
4
.
3
2
4
.
5
Y
1
7
.
3
6
5
.
3
Y
6
9
0
.
1
3
0
.
1
6
1
.
4
4
0
.
7
8
0
.
7
8
4
#
4
3.
5
1
2
16
.
5
8
6
.
9
2
8
.
6
Y
2
4
.
3
6
5
.
3
Y
1
1
4
0
.
1
8
0
.
2
7
1
.
6
8
0
.
9
1
0
.
9
1
5
#
4
4.
0
1
2
21
.
6
8
1
0
.
1
3
2
.
6
Y
3
2
.
4
6
5
.
3
Y
1
7
4
0
.
2
4
0
.
4
1
1
.
9
2
1
.
0
4
1
.
0
4
6
#
4
4.
5
1
2
27
.
3
8
1
3
.
8
3
6
.
7
Y
4
1
.
6
6
5
.
3
Y
2
5
3
0
.
3
1
0
.
6
0
2
.
1
6
1
.
1
7
1
.
1
7
4
#
5
5.
0
1
2
33
.
8
8
1
8
.
0
4
0
.
8
Y
5
1
.
8
6
5
.
3
Y
3
5
3
0
.
3
9
0
.
8
4
2
.
4
0
1
.
3
0
1
.
3
0
5
#
5
5.
5
1
2
40
.
8
8
2
2
.
8
4
4
.
9
Y
6
3
.
2
6
5
.
3
Y
4
7
6
0
.
4
9
1
.
1
4
2
.
6
4
1
.
4
3
1
.
5
1
5
#
5
6.
0
1
5
47
.
3
1
1
2
4
.
2
6
7
.
3
Y
7
2
.
3
1
1
2
.
2
Y
6
0
7
0
.
4
1
1
.
0
4
3
.
6
0
1
.
9
4
1
.
9
4
7
#
5
ON
E
W
A
Y
S
H
E
A
R
:
TW
O
W
A
Y
S
H
E
A
R
:
ESTRUCTURA USA, INC.
ADVANCED STRUCTURAL ENGINEERING
468 North Camden Orive #131E
Beverly Hills, CA. 90210
Sheet:
Job. No:
Project:
23
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
ASCE Hazards Report
Address:
2201 Halladay St
Santa Ana, California
92707
Standard:ASCE/SEI 7-22 Latitude:33.717669
Risk Category:II Longitude:-117.859522
Soil Class:Default Elevation:61.81198352982068 ft
(NAVD 88)
Page 1 of 4https://ascehazardtool.org/Thu Aug 29 2024
24
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
PGA M : 0.65
SMS : 1.73
SM1 : 1.17
SDS : 1.15
SD1 : 0.78
T L : 8
SS : 1.46
S1 : 0.49
VS30 : 260
Seismic Design Category: D
Multi-Period Design Spectrum
S (g) vs T(s)a
Multi-Period MCE SpectrumR
S (g) vs T(s)a
Two-Period Design Spectrum
S (g) vs T(s)a
Two-Period MCE SpectrumR
S (g) vs T(s)a
Design Vertical Response Spectrum
Vertical ground motion data has not yet been made
available by USGS.
MCE Vertical Response SpectrumR
Vertical ground motion data has not yet been made
available by USGS.
Seismic
DefaultSite Soil Class:
Results:
Page 2 of 4https://ascehazardtool.org/Thu Aug 29 2024
25
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
SEISMIC BASE SHEAR (ASCE7-22)
Latitude:33.717669
Longitude: -117.859522
D (Table 20.3-1)ρ=1.3
R=6.5 (Table 12.2-1)I 1
(Section 21.4)
1.730 0
1.170 0
(11.4-3)
1.153
(11.4-4)
0.78 0.13526012
0.67630058
See on Figs. 22-14 through 22-17
0.02
8.000
0.75
0.095
W= Effective seismeic weight
(GOVERNS)
For S1 is equal to greater than 0.6g
0.090 W
1.261 W
0.177
0.231 W Strength Level
0.161 W Allowable Stress Design
𝑆=
𝑆=
𝑆=3 𝑆
=
𝑆=3 𝑆
=
𝑇= 𝐶ℎ
=
ℎ=
𝑥=
=
=
=.
=
=
=
=
==
==
=
=
=
26
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
SEISMIC ANALYSIS
WEIGHT
Level 1 W roof = 20 psf x 805 ft^2 =16.09 kips
W wall = 16 psf x 432 ft^2 =6.91 kips
WR = 23.00 kips
BASE SHEAR
0.161 x 23.00 kips = 3.71 kips
F1=
DISTRIBUTION OF BASE SHEAR
1 Level
2 or more levels
W TOTAL
23.00 kips
4.617 psf
𝑽𝑩𝑨𝑺𝑬= 𝑽 ∗ 𝑾𝑻𝑶𝑻𝑨𝑳
= 𝑉 ∗ 𝑊=
𝑭𝒙= 𝑽𝑩𝑨𝑺𝑬∗𝑾𝑿∗ 𝒉𝑻𝑶𝑻𝑨𝑳
𝑾𝟏∗ 𝒉𝟏+𝑾𝟐∗𝒉𝟏+ 𝒉𝟐+ ⋯𝑾𝒏∗ 𝒉𝑻𝑶𝑻𝑨𝑳
𝑩𝑨𝑺𝑬=∗𝑻𝑶𝑻𝑨𝑳
𝑨
27
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
INPUT DATA
B
I = 1.00 Category II
V = 110.00 mph
Kzt = 1.00 Flat
he = 8.00 ft
hr = 12.75 ft
L = 34.00 ft
B = 20.00 ft
A = 10.00 ft2
DESIGN SUMMARY
Max horizontal force normal to building length, L, face =5.79 kips X 0.6=3.47 kips (ASD)
Max horizontal force normal to building length, B, face =3.00 kips X 0.6=1.80 kips (ASD)
Max total horizontal torsional load =25 ft-kips
Max total upward force =9.91 kips
ANALYSIS
Velocity pressure
qh = 0.00256 Kh Kzt Kd V2 I =18.43 psf
where:qh = velocity pressure at mean roof height, h.
Kh = velocity pressure exposure coefficient evaluated at height, h,= 0.70
Kd = wind directionality factor = 0.85
h = mean roof height = 10.38 ft
< 60 ft, [Satisfactory]
Design pressures for MWFRS
p = qh [(G Cpf )-(G Cpi )]
where: p = pressure in appropriate zone
G Cp f = product of gust effect factor and external pressure coefficient
G Cp i = product of gust effect factor and internal pressure coefficient
= 0.18 or -0.18
a = width of edge strips, MAX[ MIN(0.1B, 0.4h), 0.04B,3] =3.00 ft
Net Pressures (psf), Basic Load Cases
25.41 0.00
(+GCp i ) (-GCp i )(+GCp i ) (-GCp i )
1 0.55 6.75 13.38 0.40 4.05 10.69
2 -0.20 -7.06 -0.43 -0.69 -16.03 -9.40
3 -0.45 -11.67 -5.03 -0.37 -10.14 -3.50
4 -0.40 -10.64 -4.01 -0.29 -8.66 -2.03
1E 0.74 10.33 16.97 0.61 7.93 14.56
2E -0.35 -9.68 -3.05 -1.07 -23.04 -16.40
3E -0.60 -14.44 -7.80 -0.53 -13.09 -6.45
4E -0.55 -13.52 -6.88 -0.43 -11.24 -4.61
5 -0.45 -11.61 -4.98 -0.45 -11.61 -4.98
6 -0.45 -11.61 -4.98 -0.45 -11.61 -4.98
Net Pressures (psf), Torsional Load Cases
25.41
(+GCp i ) (-GCp i )
1T 0.55 1.69 3.35
2T -0.20 -1.77 -0.11
3T -0.45 -2.92 -1.26
4T -0.40 -2.66 -1.00
(+GCp i ) (-GCp i )
1T 0.40 1.01 2.67
2T -0.69 -4.01 -2.35
3T -0.37 -2.53 -0.88
4T -0.29 -2.17 -0.51
G Cp f
Surface
WIND ANALYSIS FOR LOW-RISE BUILDING
( BASED ON ASE 7-16/ IBC 2021/ CBC 2022)
Roof angle q =
Surface Net Pressure withG Cp f
Importance factor
Building length
Building height to ridge
Building height to eave
Topographic factor
Basic wind speed
Roof angle q =
G Cp f
Net Pressure with
Effective area of components
Exposure category (B, C or D)
Roof angle q =
Building width
Net Pressure with
Surface
Roof angle q =
G Cp f
Net Pressure with
28
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
Basic Load Cases in Transverse Direction Basic Load Cases in Longitudinal Direction
Area Area
(ft2)(+GCp i ) (-GCp i )(ft2)(+GCp i ) (-GCp i )
1 224 1.51 3.00 1 151 0.61 1.61
2 310 -2.19 -0.13 2 263 -4.22 -2.48
3 310 -3.62 -1.56 3 263 -2.67 -0.92
4 224 -2.38 -0.90 4 151 -1.31 -0.31
1E 48 0.50 0.81 1E 57 0.45 0.82
2E 66 -0.64 -0.20 2E 113 -2.60 -1.85
3E 66 -0.96 -0.52 3E 113 -1.48 -0.73
4E 48 -0.65 -0.33 4E 57 -0.64 -0.26
Horiz. 5.79 5.79 Horiz. 3.00 3.00
Vert. -6.69 -2.18 Vert. -9.91 -5.40
10 psf min.Horiz. 4.34 4.34 10 psf min.Horiz. 2.08 2.08
Vert. -6.80 -6.80 Sec. 6.1.4.1 Vert. -6.80 -6.80
Torsional Load Cases in Transverse Direction Torsional Load Cases in Longitudinal Direction
Area Area
(ft2)(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )(ft2)(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )
1 88 0.59 1.18 4 8 1 47 0.19 0.50 0 1
2 122 -0.86 -0.05 -3 0 2 151 -2.41 -1.42 9 5
3 122 -1.42 -0.61 4 2 3 151 -1.53 -0.53 -6 -2
4 88 -0.94 -0.35 7 2 4 47 -0.41 -0.10 1 0
1E 48 0.50 0.81 7 11 1E 57 0.45 0.82 3 6
2E 66 -0.64 -0.20 -4 -1 2E 113 -2.60 -1.85 9 7
3E 66 -0.96 -0.52 6 3 3E 113 -1.48 -0.73 -5 -3
4E 48 -0.65 -0.33 9 5 4E 57 -0.64 -0.26 4 2
1T 136 0.23 0.46 -2 -4 1T 104 0.11 0.28 0 -1
2T 188 -0.33 -0.02 1 0 2T 263 -1.06 -0.62 -8 -5
3T 188 -0.55 -0.24 -2 -1 3T 263 -0.67 -0.23 5 2
4T 136 -0.36 -0.14 -3 -1 4T 104 -0.22 -0.05 -1 0
25 25 11.6 11.6
Design pressures for components and cladding
p = qh[ (G Cp) - (G Cpi)]
where: p = pressure on component
pmin = 10 psf (Sec. 6.1.4.2, pg 21)
G Cp = external pressure coefficient.
see table below
Effective
Area (ft2) GCP - GCP GCP - GCP GCP - GCP GCP - GCP GCP - GCP
Comp.10 0.50 -0.90 0.50 -1.70 0.50 -2.60 1.00 -1.10 1.00 -1.40
Positive Negative Positive Negative Positive Negative Positive Negative Positive Negative
12.53 -19.91 12.53 -34.65 12.53 -51.24 21.75 -23.59 21.75 -29.12
Surface Pressure (k) with
Zone 1 Zone 2
Total Horiz. Torsional Load, MT
Comp. & Cladding Zone 1 Zone 2
Surface
Pressure
( psf )
Torsion (ft-k)
S
Surface Pressure (k) withPressure (k) with
S
Torsion (ft-k)
Total Horiz. Torsional Load, MT
Zone 5
Zone 3 Zone 4 Zone 5
Zone 3 Zone 4
Pressure (k) withSurface
29
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
30
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
F1= 4.617 psf
SW U-FORCE T.A. FORCE L1 L2 L3 L4
X1 4.62 402.25 1.86 KIPS 5.58 ft 12.00 ft
X2 4.62 402.25 1.86 KIPS 20.00 ft
Y1 4.62 249.92 1.15 KIPS 5.92 ft 3.42 ft
Y2 4.62 378.58 1.75 KIPS 6.92 ft 6.92 ft
Y3 4.62 176.00 0.81 KIPS 4.00 ft 4.00 ft
FORCES
LEVEL 1
LENGHT WALLS
31
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
DATA:
SEISMIC GOVERNS
(0.6-.14SDS) D + 0.7 E
SDS=1.15
TAG:FORCE HEIGHT
X1.1 X1.2 F1=1.86 kips h1=8.00 ft
L= 5.58 ft L= 12.00 ft
17.58 ft 1.86 kips 8.00 ft
SHEAR STRESS
1857 lbs
17.58 ft
OVERTURNING
WALL:X1.1
5.58 ft
LEVEL 1 MOT
4.72 4.72 k-ft
Uniform Loads
Load Unit Load Tributary W
(psf)(ft)(plf)
ROOF 15 10.63 159
WALL 16 8.00 128
Σw =287 plf USE:
DLR=0.44 TYPE:SHEARWALL
h/w=1.43
Vallow=340 PLF OK ST-1 USE:
HDU2 4 x
Tallow=3.08 kips OK ST-1 w/HDU2 H.D.
S/LTT20
106 plf
SHEARWALL CALCULATIONS
LEVEL 1
6
4.48 k-ft
4 POST
0.49 kips
𝐿
𝑣 =𝐹∗ 1000
=
𝑀𝑂𝑇 =𝐹 ∗𝐿
𝐿∗ ℎ
=
𝑀𝑅 =(𝛴𝑤 ∗ (𝐿))
2 =
𝑇 =𝑀𝑂𝑇 − (𝐷𝐿𝑅 ∗ 𝑀𝑅)
𝐿=
32
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
WALL:X1.2
12.00 ft
LEVEL 1 MOT
10.14 10.14 k-ft
Uniform Loads
Load Unit Load Tributary W
(psf)(ft)(plf)
ROOF 15 20.00 300
WALL 16 8.00 128
Σw =428 plf USE:
TYPE:SHEARWALL
h/w=0.67
Vallow=340 PLF OK ST-1 USE:
HDU2 4 x
Tallow=3.08 kips OK ST-1 w/HDU2 H.D.
NO
6
4 POST
30.82 k-ft
0.00 kips
𝑀𝑂𝑇 =𝐹 ∗𝐿
𝐿∗ ℎ
=
𝑀𝑅 =(𝛴𝑤 ∗ (𝐿))
2 =
𝑇 =𝑀𝑂𝑇 ∗ (𝐷𝐿𝑅 ∗ 𝑀𝑅)
𝐿=
33
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
DATA:
SEISMIC GOVERNS
(0.6-.14SDS) D + 0.7 E
SDS=1.15
TAG:FORCE HEIGHT
X2.1 F1=1.86 kips h1=8.00 ft
L= 20.00 ft
20.00 ft 1.86 kips 8.00 ft
SHEAR STRESS
1857 lbs
20.00 ft
OVERTURNING
WALL:X2.1
20.00 ft
LEVEL 1 MOT
14.86 14.86 k-ft
Uniform Loads
Load Unit Load Tributary W
(psf)(ft)(plf)
ROOF 15 10.63 159
WALL 16 8.00 128
Σw =287 plf USE:
DLR=0.44 TYPE:SHEARWALL
h/w=0.40
Vallow=340 PLF OK ST-1 USE:
HDU2 4 x
Tallow=3.08 kips OK ST-1 w/HDU2 H.D.
NO
93 plf
SHEARWALL CALCULATIONS
LEVEL 1
6
57.48 k-ft
4 POST
0.00 kips
𝐿
𝑣 =𝐹∗ 1000
=
𝑀𝑂𝑇 =𝐹 ∗𝐿
𝐿∗ ℎ
=
𝑀𝑅 =(𝛴𝑤 ∗ (𝐿))
2 =
𝑇 =𝑀𝑂𝑇 − (𝐷𝐿𝑅 ∗ 𝑀𝑅)
𝐿=
34
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
DATA:
SEISMIC GOVERNS
(0.6-.14SDS) D + 0.7 E
SDS=1.15
TAG:FORCE HEIGHT
Y1.1 Y1.2 F1=1.15 kips h1=8.00 ft
L= 5.92 ft L= 3.42 ft
9.33 ft 1.15 kips 8.00 ft
SHEAR STRESS
1154 lbs
9.33 ft
OVERTURNING
WALL:Y1.1
5.92 ft
LEVEL 1 MOT
5.85 5.85 k-ft
Uniform Loads
Load Unit Load Tributary W
(psf)(ft)(plf)
ROOF 15 1.50 23
WALL 16 8.00 128
Σw =151 plf USE:
DLR=0.44 TYPE:SHEARWALL
h/w=1.35
Vallow=340 PLF OK ST-1 USE:
HDU2 4 x
Tallow=3.08 kips OK ST-2 w/HDU2 H.D.
S/LTT20
124 plf
SHEARWALL CALCULATIONS
LEVEL 1
6
2.63 k-ft
4 POST
0.79 kips
𝐿
𝑣 =𝐹∗ 1000
=
𝑀𝑂𝑇 =𝐹 ∗𝐿
𝐿∗ ℎ
=
𝑀𝑅 =(𝛴𝑤 ∗ (𝐿))
2 =
𝑇 =𝑀𝑂𝑇 − (𝐷𝐿𝑅 ∗ 𝑀𝑅)
𝐿=
35
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
WALL:Y1.2
3.42 ft
LEVEL 1 MOT
3.38 3.38 k-ft
Uniform Loads
Load Unit Load Tributary W
(psf)(ft)(plf)
ROOF 15 20.00 300
WALL 16 8.00 128
Σw =428 plf USE:
TYPE:SHEARWALL
h/w=2.34 1.25-0.125h/b=0.96
Vallow=325 PLF OK ST-1 USE:
HDU2 4 x
Tallow=3.08 kips OK ST-1 w/HDU2 H.D.
S/LTT20
6
4 POST
2.50 k-ft
0.67 kips
𝑀𝑂𝑇 =𝐹 ∗𝐿
𝐿∗ ℎ
=
𝑀𝑅 =(𝛴𝑤 ∗ (𝐿))
2 =
𝑇 =𝑀𝑂𝑇 ∗ (𝐷𝐿𝑅 ∗ 𝑀𝑅)
𝐿=
36
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
DATA:
SEISMIC GOVERNS
(0.6-.14SDS) D + 0.7 E
SDS=1.15
TAG:FORCE HEIGHT
Y2.1 Y2.2 F1=1.75 kips h1=8.00 ft
L= 6.92 ft L= 6.92 ft
13.83 ft 1.75 kips 8.00 ft
SHEAR STRESS
1748 lbs
13.83 ft
OVERTURNING
WALL:Y2.1
6.92 ft
LEVEL 1 MOT
6.99 6.99 k-ft
Uniform Loads
Load Unit Load Tributary W
(psf)(ft)(plf)
ROOF 15 1.33 20
WALL 16 8.00 128
Σw =148 plf USE:
DLR=0.44 TYPE:SHEARWALL
h/w=1.16
Vallow=340 PLF OK ST-1 USE:
HDU2 4 x
Tallow=3.08 kips OK ST-2 w/HDU2 H.D.
S/LTT20
126 plf
SHEARWALL CALCULATIONS
LEVEL 1
6
3.54 k-ft
4 POST
0.79 kips
𝐿
𝑣 =𝐹∗ 1000
=
𝑀𝑂𝑇 =𝐹 ∗𝐿
𝐿∗ ℎ
=
𝑀𝑅 =(𝛴𝑤 ∗ (𝐿))
2 =
𝑇 =𝑀𝑂𝑇 − (𝐷𝐿𝑅 ∗ 𝑀𝑅)
𝐿=
37
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
WALL:Y2.2
6.92 ft
LEVEL 1 MOT
6.99 6.99 k-ft
Uniform Loads
Load Unit Load Tributary W
(psf)(ft)(plf)
ROOF 15 20.00 300
WALL 16 8.00 128
Σw =428 plf USE:
TYPE:SHEARWALL
h/w=1.16
Vallow=340 PLF OK ST-1 USE:
HDU2 4 x
Tallow=3.08 kips OK ST-1 w/HDU2 H.D.
S/LTT20
6
4 POST
10.24 k-ft
0.36 kips
𝑀𝑂𝑇 =𝐹 ∗𝐿
𝐿∗ ℎ
=
𝑀𝑅 =(𝛴𝑤 ∗ (𝐿))
2 =
𝑇 =𝑀𝑂𝑇 ∗ (𝐷𝐿𝑅 ∗ 𝑀𝑅)
𝐿=
38
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
DATA:
SEISMIC GOVERNS
(0.6-.14SDS) D + 0.7 E
SDS=1.15
TAG:FORCE HEIGHT
Y3.1 Y3.2 F1=0.81 kips h1=8.00 ft
L= 4.00 ft L= 4.00 ft
8.00 ft 0.81 kips 8.00 ft
SHEAR STRESS
813 lbs
8.00 ft
OVERTURNING
WALL:Y3.1
4.00 ft
LEVEL 1 MOT
3.25 3.25 k-ft
Uniform Loads
Load Unit Load Tributary W
(psf)(ft)(plf)
ROOF 15 1.50 23
WALL 16 8.00 128
Σw =151 plf USE:
DLR=0.44 TYPE:SHEARWALL
h/w=2.00
Vallow=340 PLF OK ST-1 USE:
HDU2 4 x
Tallow=3.08 kips OK ST-1 w/HDU2 H.D.
S/LTT20
102 plf
SHEARWALL CALCULATIONS
LEVEL 1
6
1.20 k-ft
4 POST
0.68 kips
𝐿
𝑣 =𝐹∗ 1000
=
𝑀𝑂𝑇 =𝐹 ∗𝐿
𝐿∗ ℎ
=
𝑀𝑅 =(𝛴𝑤 ∗ (𝐿))
2 =
𝑇 =𝑀𝑂𝑇 − (𝐷𝐿𝑅 ∗ 𝑀𝑅)
𝐿=
39
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
WALL:Y3.2
4.00 ft
LEVEL 1 MOT
3.25 3.25 k-ft
Uniform Loads
Load Unit Load Tributary W
(psf)(ft)(plf)
ROOF 15 20.00 300
WALL 16 8.00 128
Σw =428 plf USE:
TYPE:SHEARWALL
h/w=2.00
Vallow=340 PLF OK ST-1 USE:
HDU2 4 x
Tallow=3.08 kips OK ST-1 w/HDU2 H.D.
S/LTT20
6
4 POST
3.42 k-ft
0.44 kips
𝑀𝑂𝑇 =𝐹 ∗𝐿
𝐿∗ ℎ
=
𝑀𝑅 =(𝛴𝑤 ∗ (𝐿))
2 =
𝑇 =𝑀𝑂𝑇 ∗ (𝐷𝐿𝑅 ∗ 𝑀𝑅)
𝐿=
40
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
RFG J A� - lFARWA I SCH
SHEARWALL SCHEDULE
MARK SHEATHING NAIL EDGE FIELD SILL TO SILL TO ALLOW. SHEAR
SIZE NAIL NAIL SHEAR WALL ( 1 ) (2) SPACING SPACING WOOD CONN. (1) CONC. CONN. (1) (PLF) TYPE(3)
15/32 STR I O.S. 10d 6" 12" SDS1/4"x6" @ 16" 2x: 5/8"1/J A.B. @ 32"340 I 3x: 5/8"1/J A.B. @ 48"
15/32 STR I O.S. 10d 4" 12" SDS1/4"x6" @ 12" 3x: 5/8"1/J A.B. @ 32" 510 JI
ill 15/32 STR I O.S. 10d 3" STGR( 4) 12" SDS1/4"x6" @ 9" 3x: 5/8"1/J A.B. @ 24" 665 JI
In 15/32 STR I O.S. 10d 2" STGR( 4) 12" SDS1/4''x6" @ 6" 3x: 5/8"1/J A.B. @ 16" 870 JI
& 15/32 STR I D.S. 10d 4" 12" SDS1/4''x6" @ 6" 3x: 5/8"1/J A.B. @ 16" 1020 III
� 15/32 STR I D.S. 10d 3" STGR( 4) 12" SDS1/4''x6" @ 4" 3x: 5/8"1/J A.B. @ 12" 1330 K
A 15/32 STR I D.S. 10d 2" STGR( 4) 12" SDS1/4''x6" @ 3" 3x: 5/8"1/J A.B. @ 8" 1740 K
SHEARWALL NOTES:
(1)0.5. INDICATE5 5HEATI-HNG ON ONE 51DE OF WALL AS 5HOWN ON FLAN5.D.5. INDICATE5 DOU6LE 51DED 5HEARWALL: 5HEATHING ON 60TH 51DE5 OF WALL
(2)USE COMMON WIRE NAIL5 FOR ALL STRUCT-1 5HEATHING.
ESTRUCTURA USA, INC.
ADVANCED STRUCTURAL ENGINEERING
468 North Camden Orive #131E
Beverly Hills, CA. 90210
Sheet:
Job. No:
Project:
41
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
REMARKS
4x4
4x4
4X4
4X6
4X67.15
10.83
ALLOWABLE
75%
2.31
3.42
4.23
6X6HDU14
3.075
4.565
5.645
6.970
9.535
14.445
5.23
HDU5
HDU8
HDU11
HOLDOWNS
HDU2
HDU4
HD ALLOWABLE
UPLIFT
ESTRUCTURA USA, INC.
ADVANCED STRUCTURAL ENGINEERING
468 North Camden Orive #131E
Beverly Hills, CA. 90210
Sheet:
Job. No:
Project:
42
24-204
2201 HALLADAY ST.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
STRUCTURAL NOTES
CHECK AND VERIFY ALL DIMENSIONS
BEFORE PROCEEDING WITH THE WORK.
REPORT DISCREPANCIES TO THE
ENGINEER. ALL CONSTRUCTION SHALL
CONFORM TO THE C.B.C.
ENGINEER:
Margarito Castillo, S.E.
MARK DATE REVISIONS
STRUCTURAL NOTES:
JOB NO:
DRAWN:
CHECKED:
DATE:
ARCHITECT:
SKY CONSTRUCTION INC.
468 N Camden Dr # 200,
Beverly Hills, CA 90210
(310) 658-1225
estructuramx
PROJECT :
2201 HALLADAY ST.
PROJECT ADDRESS:
2201 HALLADAY ST.
STA. ANA, CA 92707
SHEET NO.:
SHEET TITLE:
24-204
DA
MC
29 AUG 24
hello@emxse.com
emxse.com
1 09/26/24 PLAN CHECK
09/26/24
DATE OF SIGN
1
02-S1.0
STRUCTURAL NOTES
940 E Anahurst Pl & 2201
S Halladay11/25/2024
I II III IV
VIIIVIIVIV
XIIXIXIX
CHECK AND VERIFY ALL DIMENSIONS
BEFORE PROCEEDING WITH THE WORK.
REPORT DISCREPANCIES TO THE
ENGINEER. ALL CONSTRUCTION SHALL
CONFORM TO THE C.B.C.
ENGINEER:
Margarito Castillo, S.E.
MARK DATE REVISIONS
STRUCTURAL NOTES:
JOB NO:
DRAWN:
CHECKED:
DATE:
ARCHITECT:
SKY CONSTRUCTION INC.
468 N Camden Dr # 200,
Beverly Hills, CA 90210
(310) 658-1225
estructuramx
PROJECT :
2201 HALLADAY ST.
PROJECT ADDRESS:
2201 HALLADAY ST.
STA. ANA, CA 92707
SHEET NO.:
SHEET TITLE:
24-204
DA
MC
29 AUG 24
hello@emxse.com
emxse.com
1 09/26/24 PLAN CHECK
09/26/24
DATE OF SIGN
1
02-S1.1
ALL TYPICAL DETAILS
TYPICAL DETAILS
940 E Anahurst Pl & 2201
S Halladay11/25/2024
I II
VIVIII
VI VII VIII
CHECK AND VERIFY ALL DIMENSIONS
BEFORE PROCEEDING WITH THE WORK.
REPORT DISCREPANCIES TO THE
ENGINEER. ALL CONSTRUCTION SHALL
CONFORM TO THE C.B.C.
ENGINEER:
Margarito Castillo, S.E.
MARK DATE REVISIONS
STRUCTURAL NOTES:
JOB NO:
DRAWN:
CHECKED:
DATE:
ARCHITECT:
SKY CONSTRUCTION INC.
468 N Camden Dr # 200,
Beverly Hills, CA 90210
(310) 658-1225
estructuramx
PROJECT :
2201 HALLADAY ST.
PROJECT ADDRESS:
2201 HALLADAY ST.
STA. ANA, CA 92707
SHEET NO.:
SHEET TITLE:
24-204
DA
MC
29 AUG 24
hello@emxse.com
emxse.com
1 09/26/24 PLAN CHECK
09/26/24
DATE OF SIGN
1
02-S1.2
ALL TYPICAL DETAILS
TYPICAL DETAILS
940 E Anahurst Pl & 2201
S Halladay11/25/2024
I II III IV
VIIIVIIVIV
CHECK AND VERIFY ALL DIMENSIONS
BEFORE PROCEEDING WITH THE WORK.
REPORT DISCREPANCIES TO THE
ENGINEER. ALL CONSTRUCTION SHALL
CONFORM TO THE C.B.C.
ENGINEER:
Margarito Castillo, S.E.
MARK DATE REVISIONS
STRUCTURAL NOTES:
JOB NO:
DRAWN:
CHECKED:
DATE:
ARCHITECT:
SKY CONSTRUCTION INC.
468 N Camden Dr # 200,
Beverly Hills, CA 90210
(310) 658-1225
estructuramx
PROJECT :
2201 HALLADAY ST.
PROJECT ADDRESS:
2201 HALLADAY ST.
STA. ANA, CA 92707
SHEET NO.:
SHEET TITLE:
24-204
DA
MC
29 AUG 24
hello@emxse.com
emxse.com
1 09/26/24 PLAN CHECK
09/26/24
DATE OF SIGN
1
02-S1.3
ALL TYPICAL DETAILS
TYPICAL DETAILS
940 E Anahurst Pl & 2201
S Halladay11/25/2024
SCALE: = 1'-0"I FOUNDATION PLAN
1/4"
N
1
2
2
CHECK AND VERIFY ALL DIMENSIONS
BEFORE PROCEEDING WITH THE WORK.
REPORT DISCREPANCIES TO THE
ENGINEER. ALL CONSTRUCTION SHALL
CONFORM TO THE C.B.C.
ENGINEER:
Margarito Castillo, S.E.
MARK DATE REVISIONS
STRUCTURAL NOTES:
JOB NO:
DRAWN:
CHECKED:
DATE:
ARCHITECT:
SKY CONSTRUCTION INC.
468 N Camden Dr # 200,
Beverly Hills, CA 90210
(310) 658-1225
estructuramx
PROJECT :
2201 HALLADAY ST.
PROJECT ADDRESS:
2201 HALLADAY ST.
STA. ANA, CA 92707
SHEET NO.:
SHEET TITLE:
24-204
DA
MC
29 AUG 24
hello@emxse.com
emxse.com
1 09/26/24 PLAN CHECK
09/26/24
DATE OF SIGN
1
2 10/16/24 PLAN CHECK
02-S2.0
FOUNDATION PLAN
940 E Anahurst Pl & 2201
S Halladay11/25/2024
SCALE: = 1'-0"2 ROOF FRAMING PLAN
1/4"
C.J.
N
2x
1
0
C
.
J
.
@
1
6
"
O
.
C
.
2
CHECK AND VERIFY ALL DIMENSIONS
BEFORE PROCEEDING WITH THE WORK.
REPORT DISCREPANCIES TO THE
ENGINEER. ALL CONSTRUCTION SHALL
CONFORM TO THE C.B.C.
ENGINEER:
Margarito Castillo, S.E.
MARK DATE REVISIONS
STRUCTURAL NOTES:
JOB NO:
DRAWN:
CHECKED:
DATE:
ARCHITECT:
SKY CONSTRUCTION INC.
468 N Camden Dr # 200,
Beverly Hills, CA 90210
(310) 658-1225
estructuramx
PROJECT :
2201 HALLADAY ST.
PROJECT ADDRESS:
2201 HALLADAY ST.
STA. ANA, CA 92707
SHEET NO.:
SHEET TITLE:
24-204
DA
MC
29 AUG 24
hello@emxse.com
emxse.com
1 09/26/24 PLAN CHECK
09/26/24
DATE OF SIGN
1
2 10/16/24 PLAN CHECK
02-S2.1
ROOF FRAMING PLAN
940 E Anahurst Pl & 2201
S Halladay11/25/2024
I II III IV
VIIIVIIVI
XIIXIXIX
1
CHECK AND VERIFY ALL DIMENSIONS
BEFORE PROCEEDING WITH THE WORK.
REPORT DISCREPANCIES TO THE
ENGINEER. ALL CONSTRUCTION SHALL
CONFORM TO THE C.B.C.
ENGINEER:
Margarito Castillo, S.E.
MARK DATE REVISIONS
STRUCTURAL NOTES:
JOB NO:
DRAWN:
CHECKED:
DATE:
ARCHITECT:
SKY CONSTRUCTION INC.
468 N Camden Dr # 200,
Beverly Hills, CA 90210
(310) 658-1225
estructuramx
PROJECT :
2201 HALLADAY ST.
PROJECT ADDRESS:
2201 HALLADAY ST.
STA. ANA, CA 92707
SHEET NO.:
SHEET TITLE:
24-204
DA
MC
29 AUG 24
hello@emxse.com
emxse.com
1 09/26/24 PLAN CHECK
09/26/24
DATE OF SIGN
1
02-S3.0
ALL TYPICAL DETAILS
FOUNDATION DETAILS
940 E Anahurst Pl & 2201
S Halladay11/25/2024
II IV
VIIIVIIVIV
XIIXIXIX
IIII
CHECK AND VERIFY ALL DIMENSIONS
BEFORE PROCEEDING WITH THE WORK.
REPORT DISCREPANCIES TO THE
ENGINEER. ALL CONSTRUCTION SHALL
CONFORM TO THE C.B.C.
ENGINEER:
Margarito Castillo, S.E.
MARK DATE REVISIONS
STRUCTURAL NOTES:
JOB NO:
DRAWN:
CHECKED:
DATE:
ARCHITECT:
SKY CONSTRUCTION INC.
468 N Camden Dr # 200,
Beverly Hills, CA 90210
(310) 658-1225
estructuramx
PROJECT :
2201 HALLADAY ST.
PROJECT ADDRESS:
2201 HALLADAY ST.
STA. ANA, CA 92707
SHEET NO.:
SHEET TITLE:
24-204
DA
MC
29 AUG 24
hello@emxse.com
emxse.com
1 09/26/24 PLAN CHECK
09/26/24
DATE OF SIGN
1
02-S5.0
ROOF FRAMING DETAILS
940 E Anahurst Pl & 2201
S Halladay11/25/2024
Project number
Date
Drawn by
Checked by
E-mail:skyaaconstruction@gmail.com
THIS DESIGN AND DRAWINGS, ARE
COPYRIGHT PROTECTED AND ARE
THE EXCLUSIVE PROPERTY OF AA SKY
CONSTRUCTION INC., THEY SHALL BE
NO USED, MODIFIED DUPLICATED IN
WHOLE OR IN ANY MANNER, NOR
ASSIGNED TO A THIRD PARTY WITHOUT
THE WRITTEN AUTHORIZATION
OF AA SKY CONSTRUCTION INC.
APPROVAL STAMP
OWNER
CONTACT PERSON
DESIGNER
AA SKY CONSTRUCTION INC.
2074 SILVERADO ST.
SAN MARCOS CA 92078
LIC#1061749
OFFICE 858 888 3752
CELL 760 845 7697
RAFAEL G LUJANO
E-MAIL: SKYAACONSTRUCTION@GMAIL.COM
CONSULTANTS
03-G-01
GREEN CODE
0001
940 E ANAHURST PL.
STA. ANA, CA 92707
05-20-2024
Autor
Verificador
EX. 400 SQ.FT.
GARAGE+ NEW 280
SQ.FT. TO BE A 680
SQ.FT. ADU
RAFAEL LUJANO
RAFAEL LUJANO
2201 HALLADAY ST. STA. ANA, CA 92707
skyaaconstruction@gmail.com
+17608457697
No. Description Date
940 E Anahurst Pl & 2201
S Halladay11/25/2024
Project number
Date
Drawn by
Checked by
E-mail:skyaaconstruction@gmail.com
THIS DESIGN AND DRAWINGS, ARE
COPYRIGHT PROTECTED AND ARE
THE EXCLUSIVE PROPERTY OF AA SKY
CONSTRUCTION INC., THEY SHALL BE
NO USED, MODIFIED DUPLICATED IN
WHOLE OR IN ANY MANNER, NOR
ASSIGNED TO A THIRD PARTY WITHOUT
THE WRITTEN AUTHORIZATION
OF AA SKY CONSTRUCTION INC.
APPROVAL STAMP
OWNER
CONTACT PERSON
DESIGNER
AA SKY CONSTRUCTION INC.
2074 SILVERADO ST.
SAN MARCOS CA 92078
LIC#1061749
OFFICE 858 888 3752
CELL 760 845 7697
RAFAEL G LUJANO
E-MAIL: SKYAACONSTRUCTION@GMAIL.COM
CONSULTANTS
03-G-02
GREEN CODE
0001
940 E ANAHURST PL.
STA. ANA, CA 92707
05-20-2024
Autor
Verificador
EX. 400 SQ.FT.
GARAGE+ NEW 280
SQ.FT. TO BE A 680
SQ.FT. ADU
RAFAEL LUJANO
RAFAEL LUJANO
2201 HALLADAY ST. STA. ANA, CA 92707
skyaaconstruction@gmail.com
+17608457697
No. Description Date
940 E Anahurst Pl & 2201
S Halladay11/25/2024
DU
C
T
I
N
S
P
E
C
T
I
O
N
S
E
R
V
I
C
E
SO
-
C
A
L
H
E
R
S
R
A
T
I
N
G
SE
R
V
I
N
G
A
L
L
O
F
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
drawing no:
date:
checked by:
drawn by:
content:
-
HC
ENV-1
08-28-24
pr
o
j
e
c
t
n
a
m
e
:
RE
S
I
D
E
N
T
I
A
L
ad
d
r
e
s
s
E
C
O
N
O
M
Y
T
I
T
L
E
2
4
60
5
5
W
.
W
A
S
H
I
N
G
T
O
N
B
L
V
D
.
CO
M
M
E
R
C
E
,
C
A
L
I
F
O
R
N
I
A
9
0
0
4
0
ec
o
n
o
m
y
t
i
t
l
e
2
4
@
y
a
h
o
o
.
c
o
m
HE
R
S
R
A
T
I
N
G
A
N
D
81
8
-
6
6
9
-
1
8
1
1
PROJECT #
R-002335
22
0
1
H
A
L
L
A
D
A
Y
S
T
R
E
E
T
SA
N
T
A
A
N
A
,
C
A
940 E Anahurst Pl & 2201
S Halladay11/25/2024
DU
C
T
I
N
S
P
E
C
T
I
O
N
S
E
R
V
I
C
E
SO
-
C
A
L
H
E
R
S
R
A
T
I
N
G
SE
R
V
I
N
G
A
L
L
O
F
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
drawing no:
date:
checked by:
drawn by:
content:
-
HC
ENV-2
PROJECT #
08-28-24
pr
o
j
e
c
t
n
a
m
e
:
RE
S
I
D
E
N
T
I
A
L
ad
d
r
e
s
s
E
C
O
N
O
M
Y
T
I
T
L
E
2
4
60
5
5
W
.
W
A
S
H
I
N
G
T
O
N
B
L
V
D
.
CO
M
M
E
R
C
E
,
C
A
L
I
F
O
R
N
I
A
9
0
0
4
0
ec
o
n
o
m
y
t
i
t
l
e
2
4
@
y
a
h
o
o
.
c
o
m
HE
R
S
R
A
T
I
N
G
A
N
D
81
8
-
6
6
9
-
1
8
1
1
R-002335
22
0
1
H
A
L
L
A
D
A
Y
S
T
R
E
E
T
SA
N
T
A
A
N
A
,
C
A
940 E Anahurst Pl & 2201
S Halladay11/25/2024
ELECTRICAL NOTES per 2022 California Electrical Code
A. PANEL LOCATIONS
B. NON-METTALIC SHEATED CABLE (CEC 334)
C. CIRCUITS AND RECEPTACLES
D. LIGHTING (CEC 210.70)
E. FANS
F. SMOKE ALARMS
LIGHTING NOTES:
NOTES:
BATHROOM EXCHAUST FANS SEC.4.506.4 MECHANICAL EXCHAUST FANS WHICH EXCHAUST
DIRECTLY FROM BATHROOM SHALL BE ENERGY STAR COMPLIANT, DUCTED TO TERMINATE OUTSIDE
LATION SYSTEM.
COVERS WHICH CLOSE WHEN THE FAN IS OFF THAT HAVE A MIN. INSULATION VALUE OF R-4.2
THE BUILDING, AND CONTROLLED BY A READILY ACCESSIBLE HUMIDSTAT OR A WHOLE HOUSE VENTIL
WHOLE HOUSE EXCHAUST FANS SEC.4.507.1 WHOLE HOUSE FANS SHALL HAVE INSULATED LOUVERS OR
HEATING AND AIR CONDITIONING DESIGN SEC.4.507.2 SYSTEM SHALL BE SIZED,DESIGNED AND
SPECIFIED ACCORDING TO ACCA,ASHRAE,OR EQUIVALENT DESIGN SOFTWARE OR METHODS.
1. ALL (E) DIMENSIONS SHOWN ARE APPROXIMATE. THE CONTRACTOR SHALL VERIFY ALL (E) DIMEN SIONS IN FIELD.
5. LOCATION OF SMOKE DETECTORS (310.9.1) IN EACH SLEEPING AREA SHALL BE CENTRALLY LOCATED IN CORRIDOR (OR AREA) LEADING TO SLEEPING
AREAS. SMOKE DETECTOR SHALL SOUND AN ALARM IN ALL SLEEPING AREAS.
2. ALL EXTERIOR WINDOWS SHALL UTILIZE MULTIPLE GLAZED PANELS CONSISTING OF NOT LESS THAN DUAL PANE GLAZING.
3. WINDOWS FOR EMERGENCY EGRESS OR RESCUE, SHALL BE OPERABLE FROM THE INSIDE TO PROVIDE A CLEAR OPENING OF 5.7 SQ.FT. MINIMUM. NET CLEAR OPENING WIDTH
DIMENSION SHALL BE 20" AND 24" MINIMUM IN HEIGHT.SILL FINISHED HEIGHT NOT MORE THAN 44" ABOVE FINISHED FLOOR LEVEL.
6. ALL GENERAL LIGHT AT KITCHEN AND BATH SHALL BE AN EFFICIENT LIGHTING.
2. SHOWERS AND TUB-SHOWERS COMBINATION SHALL BE PROVIDED WITH SEPERATE CONTROL VALVES FOR PRESSURE BALANCE.THE THERMO STATIC MIXING VALVE SHALL BE
TYPE U.P.C. 420.
3. PLUMBING FIXTURES WITH THE FOLLOWING MAXIMUM WATER USAGE'S SHALL BE INSTALLED IN THE ADDITION,WHERE APPLICABLE,AND IN EXISTING BATHS WASHROOMS,
KITCHENS, LAUNDRY,ETC,,,
a) WATER SAVING SHOWERHEADS SHALL HAVE A MAXIMUM FLOW OF 1.8 GAL PER MIN. AT 80 PSI. (CPC 408.2)
b) WATER SAVING SINK AND LAVATORY FAUCETS SHALL HAVE A MAXIMUM FLOW OF 1.5 GALLONS PER MIN.AT 60 PSI.
c) WATER CLOSETS SHALL NOT EXCEED 1.28 GALLONS PER FLUSH.
d) KITCHEN FAUCETS SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 60 PSI.
WARM AIR FURNACES ARE PROHIBITED IN BED ROOMS OR BATHROOMS UNLESS THEY ARE PROTECT VENT HEATER.
12. GLAZING IN HAZARDOUS LOCATIONS SHALL BE TEMPERED.91.2406.4:
A. INGRESS AND EGRESS DOORS
B. PANELS IN SLIDING OR SWINGING DOORS
C. DOORS AND ENCLOSURE FOR HOT TUB, BATH TUB SHOWERS (ALSO GLAZING IN WALL ENCLO SING THESE COMPARTMENTS WITHIN 5' OF STANDING SURFACE)
D. IF WITHIN 2' OF VERTICAL EDGE OF CLOSED DOOR AND WITHIN 5' OF STANDING SURFACE.
E. IN WALL ENCLOSING STAIRWAY LANDING
F. GUARDS AND HANDRAILS.
8. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLD WITH A MINIMUM FALL OF 6 INCHES WITHIN THE FIRST 10 FEET (R401.3)
9. VEHICULAR ACCESS DOORS SHALL COMPLY WITH SECTION (R612.4).
11. PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE PROVIDED IN THE LOCATIONS SPECIFIED PER SECTION R317.1 BY THE USE OF NATURALLY
DURABLE WOOD OR WOOD THAT IS PRESERVATIVE-TREATED IN ACCORDANCE WITH AWPA U1 FOR THE SPECIES, PRODUCT,PRESERVATIVE AND END USE. PRESERVATIVES
SHALL BE LISTED IN SECTION 4 OF AWPA U1.
12 PROVIDE ANTI GRAFFITI FINISH WITHIN THE FIRST 9 FEET ,MEASURED FROM THE GRADE,AT EXTERIOR WALLS AND DOORS EXCEPTION: MAINTENANCE OF BUILDING
AFFIDAVIT IS RECORDED BY THE OWNER TO COVENANT AND AGREE WITH THE CITY OF LOS ANGE LES TO REMOVE ANY GRAFFITI WITHIN 7-DAYS OF THE GRAFFITI BEING
APPLIED (6306).
3. SHOWER AND TUB ENCLOSURES SHALL BE TEM PERED (CBC 2406.4) WINDOWS AT SHOWERS AND TUBS SHALL BE TEMPERED. USE WATERPROOF 70" HIGH SHOWER WALL WITH
HIGH ABSORBENT FINISH (CBC 80.1.3)FLOORS AND WALLS IN WATER CLOSET COMPARTMENTS AND SHOWERS SHALL COMPLY WITH SECTION 807.1.1 THROUGH 807. 1.4 AND 807.2.
A. FIXED AND OPERSBLE PANELS OF SWINGING, SLIDING AND BI-FOLD DOORS ASSEMBLIES.
B. GLAZING IN A INDIVDUAL FIXED OROPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24" INCH ARC OR EITHER VERTICAL EDGE OF THE
DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE.
D. GLAZING IN RAILINGS.
E. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS.WHIRPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS WHERE THE BOTTOM EDGE
OF THE GLAZING IS LESS 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING.
Panels shall not be located in the vicinity of easily ignitable material, such as clothes, or in bathroom ( CEC 240-24(D) ).
1.Protected by rigid metal conduit,intermediate metal conduit,electrical metallic tubing,schedule 80 PVC Conduit, pipe,or other means when cable is exposed
or subject to physical damage. (CEC 334.15(b) ).
2.Protected by a 1/16 inch steel plate or sleeve,or be not less than 1-1/4 inch fromthe nearest edge of the framing member,When installed through framing members.
Steel plates or sleeves are required on all double shear walls when cable is installed either through or parrallel to framing members (CEC 334.17 ).
3.Protected by guard strip with 6 feet of attic when no permanent stairs or ladders are provided (CEC 334.23, 320.23).
4.Protected by guard strips in entire attic when permanent stairs or ladders are provided. Access panels or doors from the second floor into the attic are cinsidered
permanent access and guard strips are required in the entire attic.
5.Have a bending raduis not less than 5 times the diameter of the cable (CEC 334.24) ).
6.Supported at intervals not exceeding 4 1/2 feet and within 12" of every outlet box,cabinet or fitting (CEC 334.30) .
1.Receptacles shall be installed so that no point along the floor line in any wall space is more than 6ft. from an outlet,including any wall space 2 ft.wide or greater. Note: A
fixed panel of a sliding glass door is considered wall space. (CEC 210.52(A) ).
2.In kitchens,breakfast rooms,pantries,and dining rooms a minimum of 2-20A circuits shall be provided (CEC 210.11(c)(1) ). Counter space receptacles shall be
GFCI (CEC210.8(A) ). and installed:
At each wall counter space that is 12 in or greater (CEC 210.52(C)(1) );
No more than 48 in oc. (CEC 210.52(C)(1);
Maximum 24 in from the end of the counter (CEC 210.52(C)(1) ).
Maximum 20 in above counter surface (CEC 210.52(C)(5) ).
On island counter spaces (one receptacle min.)not more than 12 in below counter surface (CEC
210.52.11(C)(5) EXCEPTION). An island with less than 12'" behind the range top of sink is con sidered as dividing the
countertop into two seperate spaces (CEC210.52(C)(2) ).
On peninsular counter spaces (one receptacle min.)not more than 12 in below counter surface (CEC 210.52(C)(5)
Exception).
3.Bathroom shall have a seperate 20A circuit (CEC210.11(C)(3) with at least one GFCI wall receptacle within 36 in of each basin (CEC 210.8(A)(1); (CEC
210.52(D).
4.Laundry rooms shall have a seperate 20A circuit with at least one receptacle shall be provided (CEC 210.11(C)(2) ).All receptacles within 6 ft. of the sinkshall be GFC I
(CEC 210.8.(A)(7) ).
5.In garages,at least one GFCI receptacle shall be provided (CEC210.52.(G) ). All other garage recep tacle except those dedicated to an appliance or that are not accessible
shall be GFCI.(CEC 210.8(A)(2).
6.In hallway of 10 ft or more in length at least one receptacle shall be provided ( CEC 210.52(H) ).
7.Outdoor outlets shall be GFCI (CEC 210.8(3) ).One outlet shall be installed at the front of the dwelling and one at the rear of the dwelling.Receptacles shall be accessible at grade
level and not more than 6 1/2 ft above grade (CEC 210.52(E) ).
8.All crawl space receptacle shall be GFCI (CEC 210.8(A)(4) ).
9.All unfinished basement receptacles shall be GFCI unless they are not readily accessible or are service a dedicated appliances (CEC 210.8(A)(5) ).
10.All receptacles with 6 ft of a wet bar shall be GFCI (CEC 210.8(A)(7) ).
11. All receptacles on 15A or 20A branch circuits that supply family rooms,dining rooms,living rooms,parlors, libraries,dens,bedrooms,sunrooms,recreation rooms,closets, hallways, or
similar rooms,or areas shall beprotected by combination-type Arc-fault Circuit Interrupters (AFCI),including switched outlets(CEC 210.12(B) ).
12.All receptacles serving appliances or motors with a rating of 1 HP or 6 amps shall be on a seperate circuits.
13.For HVAC equipment,a seperate 15A or 20A circuit with an accessible receptacle at the equipment shall be provided within 25 ft of the equipment (CEC 210.63).If located in an
under floor area.The receptacle shall be GFCI (CEC 210.8(4) ).
1.Switched lighting shall be installed in: from an outlet,including any wall space 2 ft.wide or greater. Note: A fixed panel of a sliding glass door
All habitable rooms, Bathrooms,Hallways,and Stairways at each level.
Garages
At all outdoor entrances and exits.
In all attics, under floor areas,utility rooms,and basement used for storage.
Near HVAC equipment in attic,under floor areas,rooms or basements,with a
switch at the access point.
2.Lighting installed in a closet shall be a surface mounted or recessed flourescent fixture or a surface mounted incandescent fixture with completely enclosed
lamps.surface incandescent lighting shall be installed a minimum of 12 in. from the nearest point of a storage space. Surface fluorescent lighting and recessed
lighting shall be installed a minimum of 6 in. from the nearest point of a storage space (CEC 410.8(D).
In bathrooms containing tubs or showers,a fan capable of exhausting 50 cfm shall be installed (Energy Standards 150 (0).
In new construction,smoke alarms shall recieve their primary power from the building wiring.The wiring shall be permanent and installed without a disconnecting
switch other than those required for over current protection (CRC R314.4).
2. BATHROOMS, GARAGES, LAUNDRY ROOMS, OR UTILITY ROOMS MUST HAVE HIGH EFFICACY LIGHTING,OR AN OCCUPANT SENSOR WITH A MANUAL-ON/OFF
FEATURE MAY BE INSTALLED.
3. BEDROOMS,LIVING ROOMS,FAMILY ROOMS,AND OTHER ROOMS USED FOR LIVING AND SLEEPING MUST HAVE HIGH EFFICACY LIGHTING,OR AN
OCCUPANT SENSOR WITH A MANUAL -ON/OFF FEATURE OR DIMMER MAY BE INSTALLED.
4. EXTERIOR LIGHTING MUST BE HIGH EFFICACY OR AN OCCUPANT SENSOR WITH AN INTEGRAL PHOTO CONTROL MAY BE INSTALLED.
1. THE FLOW RATES FOR ALL NEW PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATE SPECIFIED IN SECTION 4.303.1
2. WHEN THE SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, AND/OR OTHER OUTLETS CONTROLLED BU A SINGLE VALVE SHALL NOT EXCEED 2.0
GALLONS PER MINUTE AT 80 PSI, THE SHOWER SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE OPERATED AT A TIME.
ROOF NOTES:
ARCHITECTURAL PLAN NOTES:
1. KITCHEN RANGE HOODS SHALL BE INSTALLED FOR COOKING FACILITIES WITH AN APPROVED FORCED-DRAFT SYSTEM OF VENTILATION
VENTED TO THE OUTSIDE OF THE BUILDING. DUCTS USED FOR DOMESTIC KITCHEN RANGE VENTILATION SHALL BE OF METAL, OR OTHER
APPROVED MATERIAL, AND SHALL HAVE SMOOTH INTERIOR SURFACES. DUCTS FOR DOMESTIC RANGE HOODS SHALL ONLY SERVE COOKING
APPLIANCES. (CMC 504.3; 3:& 150.0 (o) 1G, 2B)
KITCHEN NOTES:
4. ELEMENTS SHOWN ON THIS PLAN ARE NEW UNLESS LABELED AS EXISTING "(E)" OR SHOWN ON THE EXISTING FLOOR PLAN.
7. DOORS AND WINDOWS SHALL BE CENTERED ON WALLS AS SHOWN, UNLESS SPECIFICALLY DIMENSIONED.
BATHROOM NOTES:
1. BATHROOMS SHALL BE PROVIDED WITH MECHANICAL VENTILATION OF 50 CFM INTERMITTENT OR 20 CFM CONTINUOUS.
4. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS W ITH A SHOWERHEAD, AND SHOWER COMPARTIMENTS SHALL BE FINISHED
WITH A NONABSORBENT SURFACE EXTENDING TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR.
5. ACCESS TO BATHROOM FIXTURES: WATER CLOSETS SHALL BE SET AT LEAST 15" FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION.
THE CLEAR SPACE IN FRONT OF ANY WATER CLOSET SHALL BE NOT LESS THAN 24".
9. SHOWER COMPARTMENTS SHALL HAVE A MINIMUM FINISHED INTERIOR OF 1,024 SQ. IN. AND SHALL BE CAPABLE OF
ENCOMPASSING A 30" CIRCLE.
7. SHOWER SHALL BE PROVIDED WITH MIXING VALVE THAT WILL PROVIDE SCALD AND THERMAL SHOCK PROTECTION IN ACORDANCE
WITH ASSE 1016 OR ASME A112.18.1/SCA B125.1. (CPC. 408.3)
e) INSULATION OF DOMESTIC HOT WATER PIPING SHALL BE IN ACCORADNCE WITH CPC SECTION 609.11.1 ANS SECTION 609.11.2
5. EXTERIOR LANDING OR FLOOR AT EXTERIOR DOORS SHALL BE A MAXIMUM OF 7-3/4" BELOW THE TOP THRESHOLD THE THE DOOR DOES
NOT SWING OUT OVER THE LANDING OR FLOOR. IF DOOR SW INGS OUTWARD, A LANDING SHALL BE 1.5" MAXIMUM BELOW THE TOP OF
THRESHOLD. LANDINGS AT DOORS SHALL HAVE A LENGTH MEASURED IN DIRECTION OF TRAVEL NOT LESS THAN 36". LANDINGS SHALL
SLOPE AWAY FROM THE DWELLING AT 2% MAXIMUM (SLOPE.11.3)
SAFETY GLAZING IS REQUIRED IN THE FOLLOWING LOCATIONS:
6. SHOWER CONTROL - CONTROL VALVES AND SHOWERHEADS SHALL BE LOCATED ON THE SIDE OF SHOWER COMPARTMENTS OR
OTHERWISE ARRANGED SO THAT THE SHOWERHEAD DOES NOT DISCHARGE DIRECTLY AT THE ENTRANCE OF THE COMPARTMENT
SO THAT THE BATHER CAN ADJUST THE VALVES PRIOR TO STEPPING INTO THE SHOWER SPRAY (CPC 408.9)
8. SHOWER THRESHOLD SHALL BE NO LESS THAN 2" ABOVE THE SHOWER DRAIN. THE FINISHED FLOOR OF THE RECEPTOR SHALL
SLOPE UNIFORMLY FROM THE SIDES TOWARDS THE DRAIN NO LESS THAN1/4"" PER FOOT AND NO MORE THAN 1/2" PER FOOT
(CPC408.5)
10. BATHROOM AND EXHAUST FAN(S) SHALL BE OF THE FALLOWING.
a. ENERGY STAR COMPLIANT
b. BE DUCTED TO TERMINATE OUTSIDE THE BUILDING
c. BE RATED FOR SOUND AT A MAXIMUM OF 3 ZONE
d. SWITCHED SEPARATELY FROM LIGHTING.
a. KITCHEN VENTED RANGE HOOD.
i HERS VERIFICATION OF AIRFLOW AND SOUND RATING
ii MINIMUM AIRFLOW OF 100 CFM
iii MAXIMUM ZONE RATING. OF 3.0
C. GLAZING IN AN INDIVUAL FIXED OR OPERABLE PANEL THAT MEET ALL OF THE FOLLOWING CONDITIONS:
1) EXPOSED AREA OF AN INDIVUAL PANE GREATER THAN 9 SQUARE FEET.
2) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR
3) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR
4) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE GLAZING.
A MINIMUM OF 50% OF THE LUMINARIES IN A KITCHEN MUST BE HIGH EFFICACY.
PLUMBING NOTES:
13. EMERGENCY ESCAPE AND RESCUE OPENINGS: BASEMENTS, HABITABLE ATTICS, AND EVERY SLEEPING ROOM SHALL BE PROVIDED WITH AN
OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. THE BOTTOM OF THE CLEAR OPENING SHALL NOT BE MORE THAN 44" ABOVE THE
FLOOR. OPENINGS SHALL OPEN DIRECTLY INTO A PUBLIC WAY, OR TO A YARD OR COURT THAT OPENS TO A PUBLIC WAY. WHEN LOCATED AT THE
GRADE FLOOR, THE NET CLEAR OPENING SHALL BE AT LEAST 5 SQ. FT. ELSEWHERE, THE NET CLEAR OPENING SHALL BE AT LEAST 5.7 SQ. FT.
THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24". THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20". OPENINGS SHALL BE
OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS, OR SPECIAL KNOWLEDGE. BARS, GRILLES, COVERS,
SCREENS OR SIMILAR DEVICES ARE PERMITTED TO BE PLACED OVER EMERGENCY ESCAPE AND RESCUE OPENINGS, PROVIDED THE MINIMUM
NET CLEAR OPENING SIZE COMPLIES AS DESCRIBED ABOVE. SUCH DEVICES SHALL BE RELEASABLE OR REMOVABLE FROM THE INSIDE WITHOUT
THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR FORCE GREATER THAN THAT WHICH IS REQUIRED FOR NORMAL OPERATION OF THE ESCAPE
AND RESCUE OPENING. SECURITY BARS (BURGLAR BARS) SHALL COMPLY WITH CALIFORNIA REFERENCED STANDARDS CODE (TITLE 24, PART 12)
CHAPTER 12-3.
14. WINDOW SILLS, FALL PROTECTION: WHERE THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN 72" ABOVE THE FINISHED
GRADE OR SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MINIMUM OF 24" ABOVE THE FINISHED
FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED. OTHERWISE, OPENINGS SHALL NOT ALLOW THE PASSAGE OF A 4" DIAMETER
SPHERE, OR A CODE-COMPLIANT FALL PREVENTION OR OPENING LIMITING DEVICE SHALL BE PROVIDED.
15. ATTIC ACCESS: AN ATTIC ACCESS SHALL BE LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION. 30" MINIMUM
HEADROOM IS REQUIRED ABOVE THE ACCESS OPENING. THE ROUGH-FRAMED OPENING SHALL BE AT LEAST 22" x 30". WHEN EQUIPMENT IS
LOCATED IN THE ATTIC, THE ACCESS OPENING SHALL BE AT LEAST AS LARGE AS THE LARGEST COMPONENT OF THE EQUIPMENT.
16. WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, THE INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH
SMOKE ALARMS AND CARBON MONOXIDE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. (CRC R314.2.2 & R315.2.1) SMOKE ALARMS
SHALL BE PROVIDED IN EACH BEDROOM, OUTSIDE EACH BEDROOM IN THE IMMEDIATE VICINITY AND ON EVERY LEVEL. (CRC R314.3) CARBON
MONOXIDE ALARMS SHALL BE PROVIDED OUTSIDE EACH BEDROOM IN THE IMMEDIATE VICINITY AND ON EVERY LEVEL. (CRC R315.3) ALL
SMOKE DETECTORS 10 YEARS OR OLDER SHALL BE REPLACED.
1. RECESSED DOWNLIGHT LUMINAIRES IN CEILING . IN ADDITION TO COMPLYING WITH 150.0 (k) LUMINAIRIES RECESSED INTO CEILINGS SHALL MEET ALL OF
OF THE FALLIWING REQUIREMENTS.
a. BE LISTED, AS DEFINED IN SECTION 100.0, FOR ZERO CLEARANCE INSULATION CONTACT (IC) BY UNDERWRITERS LABORATORIES OR OTHER NATIONALLY
RECOGNIZED TESTING/RATING LABORATORY: AND
b. HAVE A LABEL THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WITH AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS WHEN TESTED IN ACCORDANCE WITH
ASTM E283. AN EXHAUST FAN HOUSING SAHALL NOT BE REQUIERD TO BE CERTIFIED AIRTIGHT: AND
c. BE SEALED WITH A GASKET OR KAULK BETWEEN THE LUMINAIRE HOUSING AND CEILING, AND HAVE ALL AIR LEAK PATHS BETWEEN CONDITIONED AND
UNCONDITIONED SPACES SEALED WITH A GASKET OR CAULK: AND
d. SHALL NOT CONTAIN SCREW BASE SOCKETS.
6. THE MINIMUM WIDTH OF HALLWAYS SHALL BE AT LEAST 3 FT.
1. GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BIFOLD DOORS.
2. GLAZING IN A FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24" ARC OF THE DOOR
IN A CLOSED POSITION, AND WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THE WALKING SURFACE.
3. GLAZING IN A FIXED OR OPERABLE PANEL MEETING ALL OF THE FOLLOWING CONDITIONS: THE EXPOSED AREA OF AN INDIVIDUAL PANE IS
LARGER THAN 9 SQ. FT.; AND THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 18" ABOVE THE FLOOR; AND THE TOP EDGE OF THE GLAZING
IS MORE THAN 36" ABOVE THE FLOOR; AND A WALKING SURFACE IS WITHIN 36" OF THE GLAZING.
4. ALL GLAZING IN RAILINGS.
5. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS WHERE
THE BOTTOM EXPOSED EDGE OF GLAZING IS LESS THAN 60" MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE.
6. GLAZING IN WALLS AND FENCES ADJACENT TO INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF
THE GLAZING IS LESS THAN 60" ABOVE A WALKING SURFACE AND WITHIN 60" OF THE WATER'S EDGE.
9. SAFETY GLAZING SHALL BE PROVIDED WITH A MANUFACTURER'S DESIGNATION OR LABEL AS REQUIRED BY THE CODE.
10. SAFETY GLAZING REQUIRED TO BE PERMANENTLY MARKED (ETCHED) AS REQUIRED BY CRC R.308.1.
8. GLAZING ADJACENT TO STAIRWAYS WITHIN 60" HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE
EXPOSED SURFACE OF THE GLAZING IS LESS THAN 60" ABOVE THE NOSE OF THE TREAD.
7. GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36" HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE
OF THE GLAZING IS LESS THAN 60" ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE.
11. GLAZING IN THE FOLLOWING LOCATIONS SHALL BE SAFETY GLAZING COMFORMING TO THE HUMAN IMPACT LOADS OF SECTION R308.3 (SEE EXCEPTIONS)
(R308.4).
1. ROOF ASSEMBLIES SHALL BE INSTALLED IN ACCORDANCE WITH THE CODE AND THE APPROVED MANUFACTURER'S INSTALLATION
INSTRUCTIONS SUCH THAT THE ROOF ASSEMBLY SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. FLASHINGS SHALL BE
INSTALLED IN A MANNER THAT PREVENTS M0ISTURE FROM ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH
M0ISTURE PERMEABLE MATERIALS AND AT INTERSECTIONS WITH PARAPET WALLS AND OTHER PENETRATIONS THROUGH THE ROOF PLANE.
2. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE PROVIDED BY
VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL BE SCREENED WITH A
CORROSION-RESISTANT MESH HAVING 1/16" - 1/8" OPENINGS.
3. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1 /150 OF THE AREA OF THE SPACE VENTILATED. REDUCTION TO
1/300 IS PERMITTED IF BETWEEN 50% AND 80% OF THE VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION
OF THE SPACE, AT LEAST 3 FEET ABOVE EAVE OR CORNICE VENTS. AS BARRIER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE
CEILING. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MINIMUM OF 1"
SPACE SHALL BE PROVIDED BETWEEN ll-lE INSULATION AND THE ROOFSHEATHING AND AT THE LOCATION OF THE VENT.
4. AN ALTERNATIVE, THE NET FREE CROSS-VENTILATING AREA MAY BE REDUCED TO 1/300 WHEN A CLASS I OR II VAPOR
IN BATHROOMS, GARAGES, LAUNDRY ROOMS, UTILITY ROOMS AND WALK-IN CLOSETS, AT LEAST ONE INSTALLED LUMINAIRE SHALL BE CONTROLLED BY AN
OCCUPANCY OR VACANCY SENSOR PROVIDING AUTOMATIC-OFF FUNCTIONALITY.
AFOR SINGLE-FAMILY RESIDENTIAL BUILDINGS, OUTDOOR LIGHTING PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING OR TO OTHER BUILDINGS ON THE
SAME LOT SHALL MEET THE REQUIREMENT IN ITEM I AND THE REQUIREMENTS IN EITHER ITEM II OR ITEM III: I. CONTROLLED BY A MANUAL ON AND OFF
CONTROL SWITCH THAT PERMITS THE AUTOMATIC ACTIONS OF ITEMS II OR III BELOW; AND II. CONTROLLED BY A PHOTOCELL AND EITHER A MOTION SENSOR
OR AN AUTOMATIC TIME SWITCH CONTROL; OR III. CONTROLLED BY AN ASTRONOMICAL TIME CLOCK CONTROL. CONTROLS THAT OVERRIDE TO ON SHALL NOT
BE ALLOWED UNLESS THE OVERRIDE AUTOMATICALLY RETURNS THE AUTOMATIC CONTROL TO ITS NORMAL OPERATION WITHIN 6 HOURS. AN ENERGY
MANAGEMENT CONTROL SYSTEM THAT PROVIDES THE SPECIFIED LIGHTING CONTROL FUNCTIONALITY AND COMPLIES WITH ALL REQUIREMENTS APPLICABLE
TO THE SPECIFIED CONTROLS MAY BE USED TO MEET THESE REQUIREMENTS.
HIGH EFFICACY LUMINARIES MUST BE PIN BASED.
RECEPTACLES IN ALL ROOMS SHALL BE AFCI PROTECTED.
ALL RECEPTACLE OUTLETS SHALL BE LISTED TAMPER-RESISTANT RECEPTACLE PER CEC 406.11.
RECESSED LIGHT FIXTURES INSTALLED IN A RATED CEILING SHALL BE RATED(IC),
(AT) AIR TIGHT, AND GASKETED OR CAULKED BETWEEN THE HOUSING AND CEILING.
LIGHTING CONTROLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF SECTION 110.9.
Project number
Date
Drawn by
Checked by
E-mail:skyaaconstruction@gmail.com
THIS DESIGN AND DRAWINGS, ARE
COPYRIGHT PROTECTED AND ARE
THE EXCLUSIVE PROPERTY OF AA SKY
CONSTRUCTION INC., THEY SHALL BE
NO USED, MODIFIED DUPLICATED IN
WHOLE OR IN ANY MANNER, NOR
ASSIGNED TO A THIRD PARTY WITHOUT
THE WRITTEN AUTHORIZATION
OF AA SKY CONSTRUCTION INC.
APPROVAL STAMP
OWNER
CONTACT PERSON
DESIGNER
AA SKY CONSTRUCTION INC.
2074 SILVERADO ST.
SAN MARCOS CA 92078
LIC#1061749
OFFICE 858 888 3752
CELL 760 845 7697
RAFAEL G LUJANO
E-MAIL: SKYAACONSTRUCTION@GMAIL.COM
CONSULTANTS
05-E-01
GENERAL NOTES
0001
940 E ANAHURST PL.
STA. ANA, CA 92707
05-20-2024
Lucas
-
EX. 400 SQ.FT.
GARAGE+ NEW 280
SQ.FT. TO BE A 680
SQ.FT. ADU
RAFAEL LUJANO
RAFAEL LUJANO
2201 HALLADAY ST. STA. ANA, CA 92707
skyaaconstruction@gmail.com
+17608457697
No. Description Date
1 Revisión 1 Fecha 1
1.2 GALLONS PER MIN. AT 60 PSI.
940 E Anahurst Pl & 2201
S Halladay11/25/2024
940 E Anahurst Pl & 2201
S Halladay11/25/2024
September 26, 2024
Attn: To Whom It May Concern
I, Margarito Castillo, S.E., hereby acknowledge that I am the responsible engineer for the
structural calculations submitted for the project 2201 Halladay St. I have reviewed the documents
and confirm that, although the address listed on the structural calculations differs from my current
address, I am the licensed professional responsible for these calculations.
Enclosed with this letter is my updated contact information, and I confirm my availability for any
further inquiries related to this project.
Please feel free to reach out should you require any additional clarification or documentation.
Respectfully,
940 E Anahurst Pl & 2201
S Halladay11/25/2024
APP-13 CBC 2016
NOTICE TO PROPERTY OWNER
Dear Property Owner:
An application for a building permit has been submitted in your name listing yourself as the builder of the property improvem ents
specified at ___________________________________________________________________________________________.
We are providing you with an Owner-Builder Acknowledgment and Information Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit issued in your names as the Owner -Builder.
We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this
form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owne r,
obtain the prior approval of the permitting authority.
OWNER’S ACKNOWLEGMENT AND VERIFICATION OF INFORMATON
DIRECTIONS: Read and initial each statement below to signify you understand or verify this information.
_____1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an “Owner -Builder” build-
ing permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an
Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and
his or her employees while working on my property. My homeowner’s insurance may not provide coverage for those injuries. I
am willfully acting as an Owner-Builder and am aware of the limits of my insurance coverage for injuries to workers on my prop-
erty.
_____2. I understand building permits are not required to be signed by property owners unless they are responsible for the
construction and are not hiring a licensed Contractor to assume this responsibility.
_____3. I understand as an “Owner-Builder” I am the responsible party of record on the permit. I understand that I may protect
myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead o f my
own.
_____4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbe rs
on permits and contracts.
_____5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total
value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an
“employer” under state and federal law.
_____6. I understand if I am considered an “employer” under state and Federal law, I must register with the state and federa l
government, withhold payroll taxes, provide workers’ compensation disability insurance, and contribute to unemployment com-
pensation of each “employee.” I also understand my failure to abide by these laws may subject me to serious financial risk.
_____7. I understand under California Contractors’ State License Law, an Owner-Builder who builds single-family residential
structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontrac-
tors and the number of structures does not exceed four within any calendar years, or all of the work is performed under contr act
with a licensed general building Contractor.
_____8. I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any finan-
cial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workma n-
ship or materials.
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
940 East Anahurst Place, Santa ana CA 92707
RL
RL
RL
RL
RL
RL
RL
RL
940 E Anahurst Pl & 2201
S Halladay11/25/2024
_____9. I understand I may obtain more information regarding my obligations as an “employer” from the Internal Revenue Ser-
vice, the United States Small Business Administration, the California Department of Benefit Payments, and the California Divi-
sion of Industrial Accidents. I also understand I may contact the California Contractors’ State License Board (CSLB) at 1 -800-
321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors.
_____10. I am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I am the
party legally and financially responsible for proposed construction activity at the following ad-
dress:_________________________________________________________________________________________.
_____11. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all
applicable laws and requirements that govern Owner-Builders as well as employers.
____12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the informati on I
have provided on this form.
Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a
license, the Contractors’ State License Board may be unable to assist you with any financial loss you may sustain as a result of
a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to underst and
that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held
liable for damages. If you obtain a permit as Owner-Builder and wish to hire Contactors, you will be responsible for verifying
whether or not those Contractors are properly licensed and the status of their workers’ compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned
to the agency responsible for issuing the permit. Note: A copy of the property owner’s driver’s license, form notariza-
tion, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the
property owner’s signature.
Signature of Property Owner _____________________________________________ Date: ______________________
Print name of Owner __________________________________________________
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER’S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize
the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder
Permit for my project.
Scope of Construction Project (or Description of Work):_______________________________________________________
Project Location or Address: ____________________________________________________________________________
Name of Authorized Agent: _____________________________________________________________________________
Address of Authorized Agent:__________________________________________________________________________
Phone Number of Authorized Agent: ______________________________________________________________________
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above
information and certify its accuracy.
Property Owner’s Signature: __________________________________________________ Date:______________________
Print Name of Owner: ______________________________________________________________
Note: A copy of the owner’s driver’s license, form notarization, or other verification acceptable to the agency is re-
quired to be presented when the permit is issued to verify the property owner’s signature.
RL
RL
940 East Anahurst Place, Santa ana CA 92707
RL
RL
Rafael Lujano
11/15/2024
Garage Conversion to ADU
940 East Anahurst Place, Santa ana CA 92707
Rafael Lujano
2201 S Halladay st Santa Ana CA.92707
760-845-7697
Rafael Lujano
11/15/2024
940 E Anahurst Pl & 2201
S Halladay11/25/2024
O R A N G E C O U N T Y F I R E A U T H O R I T Y
Plan Submittal Criteria Form
Required for Single Family or Duplex Residences
(Use Commercial form for lots with 3+ dwelling units or new residential tracts)
Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification.
Project Information
New Single Family Residence/Duplex Addition/Remodel ADU Other
Address: Unit #: City or Unincorporated County Area: ZIP:
Scope of Work:
Existing Area to Total Resulting Stories: Area Added in Past 2 Years
Yes No Questionnaire OCFA Plan Type if “Yes”
1. New – Is this a new single family residence or duplex? *(PR160) Residential Site
with Water Availability
2. ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler
Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire
sprinkler retrofit based on a threshold set by local ordinance?
(PR400-402) Fire Sprinkler
4. Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site
5. Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non-
sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all
*(PR160) Residential Site
with Water Availability
6. Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or
removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed
(PR400-402) Fire Sprinkler
Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a
garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold
*(PR160) Residential Site
(PR400-402) Fire Sprinkler
8. Gate – Is a gate being installed across a driveway or road that is designated as a fire department
access roadway, or a driveway or road that serves more than a single home/duplex?
(PR180) Gate
9. Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal
Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas
seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only
applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000
*(PR160) Residential Site
*(PR172-174) Methane
Test/Mitigation Plans
10. Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to
slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation,
or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as
*(PR125) Fuel Modification
(PR182) Accessory
Structure
*OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals.
Applicant Certification
I certify, under penalty of perjury, under the laws of the State of California, that the information above is true:
Print Name:_______________________________________ Signature:___________________________________________ Date:______________
Phone Number:_____________________________________________ Email:_____________________________________________________________
Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a
written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required.
______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes”
and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral
Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination.
For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100
SFR
400 280 680
x
940 E Anahurst Pl & 2201
S Halladay11/25/2024