HomeMy WebLinkAboutCANCELLED-1012 N King St - PlanSHEET # T-1 T-2 PV-1 PV-2 PV-3 E-1 E-2 S-1 S-2 S-3 S-4 S-5 S-6 SHEET NAME COVER SHEET PLAN NOTES SITE PLAN LAYOUT ATTACHMENT DETAILS MOUNTING DETAILS ELECTRICAL DIAGRAM WARNING LABELS SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET PROJECT INFORMATION PROPERTY OWNER NAME:ROGELIO ROSALES PHONE:- CONTRACTOR NAME:SOLGEN CONSTRUCTION PHONE:(559)442-9887 DESIGN SPECIFICATIONS OCCUPANCY: R-3 CONSTRUCTION TYPE: SINGLE FAMILY RESIDENCE ZONING: RESIDENTIAL GROUND SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 110 MPH APPLICABLE CODES & STANDARDS 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ENERGY CODE (ENERGY) 2022 CALIFORNIA GREEN BUILDING CODE (CALGREEN) 2020 NATIONAL ELECTRICAL CODE (NEC) 2022 CALIFORNIA FIRE CODE (CFC) COORDINATES: 33.753826, -117.901969 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1012 N KING ST, SANTA ANA, CA 92706 APN:40521403 DATE:2/6/2024 ROSALES RESIDENCE License#: C-10 1053344 DESIGNER: OAV CORE ENERGY GROUP. ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 T-1 AERIAL VIEW ROSALES RESIDENCE NEW PHOTOVOLTAIC SYSTEM PROJECT - 4.345 kW DC /4.608 kW AC TYPE OF INTERCONNECTION: BACKFEED BREAKER IN THE SSP SCOPE OF WORK NEW SYSTEM SIZE: STC: 11 X 395W = 4.345kW PTC: 11 X 366.6W = 4.033kW (11)JINKO SOLAR JKM395M-72HL-V(395W) MODULES (6)AP SYSTEM DS3-L MICROINVERTERS (1)100A PV LOAD CENTER (1)60A KNIFE AC DISCONNECT (1)125A SUB SERVICE PANEL EXISTING SYSTEM SIZE: (12) PHONO SOLAR PS2250P(250W) MODULES (12) ENPHASE IQ-6-60-2 US MICROINVERTERS (1) PV PRODUCTION METER (1)30A KNIFE AC DISCONNECT MSP UPGRADE: NO MAIN BREAKER DERATE: NO RACKING & MOUNTING PV ATTACHMENT TYPE: EVEREST ALL TILE HOOK FOR W TILE ROOF & QUICK MOUNT PV QMLSH-7 WITH CHEM LINK FOR FLAT ROLLED SHINGLE ROOF RACKING TYPE: EVEREST CROSSRAIL- ROOF MOUNT RACKING HARDWARE EXISTING PV SYSTEM : DC SYSTEM SIZE:-3.000 kW AC SYSTEM SIZE:-2.880 kW COMBINED PV SYSTEM : DC SYSTEM SIZE:-7.345 kW AC SYSTEM SIZE:-7.488 kW Signed: 09/20/2023 Structural Only The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101118433 Elec# 20182221 Approvals: Elec: MSmith 1012 N King St- 101118433, 201822213/13/2024 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1012 N KING ST, SANTA ANA, CA 92706 APN:40521403 DATE:2/6/2024 ROSALES RESIDENCE License#: C-10 1053344 DESIGNER: OAV CORE ENERGY GROUP. ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 T-2 1.1.PROJECT NOTES: 1.2. THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE 2022 CALIFORNIA ELECTRICAL CODE (CEC) ARTICLE 690, ALL MANUFACTURER’S LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S (AHJ) APPLICABLE CODES. 1.3. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 1.4. GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE MICROINVERTER IN ACCORDANCE WITH 2022 CEC 690.41(B) 1.5. ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY 2022 CEC 690.4 PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY 1.6. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO 2022 CEC 690.7. 1.7. ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [ 2022 CEC 110.3]. 1.8. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE CEC AND AHJ. 1.9.SCOPE OF WORK: 1.10. PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. 1.11.WORK INCLUDES: 1.12. PV ROOF ATTACHMENTS - EVEREST ALL TILE HOOK FOR W TILE ROOF & QUICK MOUNT PV QMLSH-7 WITH CHEM LINK FOR FLAT ROLLED SHINGLE ROOF 1.13. PV RACKING SYSTEM INSTALLATION - EVEREST CROSSRAIL ROOF MOUNT RACKING HARDWARE 1.14. PV MODULE AND INVERTER INSTALLATION - JINKO SOLAR JKM395M-72HL-V(395W) MODULES / AP SYSTEM DS3-L MICROINVERTERS 1.15. PV EQUIPMENT GROUNDING 1.16. PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX 1.17. PV LOAD CENTERS (IF INCLUDED) 1.18. PV METERING/MONITORING (IF INCLUDED) 1.19. PV DISCONNECTS 1.20. PV GROUNDING ELECTRODE & BONDING TO (E) GEC 1.21. PV FINAL COMMISSIONING 1.22. (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV 1.23. SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE 1.24.SITE NOTES: 1.25. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 1.26. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 1.27. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 1.28. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION 2022 CEC 110.26. 1.29. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. 1.30.EQUIPMENT LOCATIONS: 1.31. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY 2022 CEC 110.26. 1.32. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY 2022 CEC 690.31 (A),(C) AND CEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C) 1.33. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO 2022 CEC 690.34. 1.34. ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT . 1.35. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO 2022 CEC APPLICABLE CODES. 1.36. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 1.37.STRUCTURAL NOTES: 1.38. RACKING SYSTEM 1.39. PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND 1.40. A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. 1.41. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED SEALED PER LOCAL REQUIREMENTS. 1.42. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 1.43. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 1.44. WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. 1.45.WIRING & CONDUIT NOTES: 1.46. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 1.47. CONDUCTORS SIZED ACCORDING TO 2022 CEC 690.8, 2022 CEC 690.7. 1.48. VOLTAGE DROP LIMITED TO 1.5%. 1.49. DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE WIRING CLIPS. 1.50. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [2022 CEC 110.15 1.51.GROUNDING NOTES: 1.52. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 1.53. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO 2022 CEC 690.43 AND MINIMUM 2022 CEC TABLE 250.122. 1.54. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORDING WITH 2022 CEC 250.134 AND 2022 250.136(A). 1.55. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO CEC 690.45 AND MICROINVERTER MANUFACTURER'S INSTRUCTIONS. 1.56. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 1.57. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 1.58. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [2022 CEC 250.119] 1.59. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH CEC 690.47 AND CEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO CEC 250, CEC 690.47 AND AHJ. 1.60. GROUND-FAULT DETECTION SHALL COMPLY WITH CEC 690.41 IN GENERAL AND CEC 690.41 (A)(1) SPECIFICALLY. 1.61.DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 1.62. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 1.63. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 1.64. RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 1 FT OF PV ARRAY OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLED CONDUCTORS ≤30V AND ≤240VA [CEC 690.12(B)]. LOCATION OF LABEL ACCORDING TO AHJ 1.65. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO CEC 690.8, 690.9, AND 240. 1.66. EQUIPMENT THAT IS LISTED, LABELED, OR BOTH SHALL BE INSTALLED AND USED IN ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTING OR LABELING. CEC 110.3(B). 1.67. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO CEC 690.11 AND UL1699B. 1.68.ELECTRICAL INTERCONNECTION NOTES: 1.69. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120% OF THE BUSBAR RATING. 1.70. WHEN THE SUM OF THE PV SOURCES EQUALS >100% OF THE BUSBAR RATING, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD. 1.71. AT MULTIPLE PV OUTPUT COMBINER PANEL, THE TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED. 1.72. 1.72. SUPPLY-SIDE TAP INTERCONNECTION SHOULD BE WITH SERVICE ENTRANCE CONDUCTORS. 1.73. BACKFEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING. Signed: 09/20/2023 Structural Only 1012 N King St- 101118433, 201822213/13/2024 1'-6" 1'-6" 1'-6" N 3' 3' SCALE: 1/16" = 1'-0" PV SYSTEM SITE PLAN PV SYSTEM SIZE: 4.345 kW DC LEGEND CONSTRUCTION NOTES NEW SOLAR PANELS (11) JINKO SOLAR JKM395M-72HL-V(395W) WITH (6) AP SYSTEM DS3-L MICROINVERTERS ATTACHED TO THE BACK OF MODULES MOUNTED ON W TILE ROOF & FLAT ROLLED SHINGLE ROOF 1012 N KING ST ROOF OBSTRUCTIONS SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1012 N KING ST, SANTA ANA, CA 92706 APN:40521403 DATE:2/6/2024 ROSALES RESIDENCE License#: C-10 1053344 DESIGNER: OAV CORE ENERGY GROUP. ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 PV-1 ACD AC DISCONNECT LC LOAD CENTER (E)DETACHED STRUCTURE ON PROPERTY 1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. 2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITHSTAND A BASIC WIND SPEED OF 110 MPH (3 SECOND GUST), WIND EXPOSURE C. 3. THE ROOF MEMBERS ARE 2 "X 4" TRUSSES AT 24" ON CENTER. CONNECTION TO STRUCTURE SHALL NOT BE WITHIN 11" OF NAILING PLATES. 4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF SHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 6. ROOF ACCESS POINTS SHALL BE PROVIDED PER THE FOLLOWING (CRC R324.6, CBC 3111.3.4) 6.1. LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. 6.2. LOCATED AT STRONG POINTS OF CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS: TREES, WIRES, OR SIGNS. 7. SETBACKS AT RIDGES CAN BE REDUCED TO 18 INCHES IN COMPLIANCE WITH 2022 CFC/2021 IFC 1205.2.1.2 TOTAL PLAN VIEW AREA FOR NEW SYSTEM = 2761.28 SQFT TOTAL PV AREA = 11(79.06 IN)(39.45 IN)/(144 IN^2) = 238.25 SQFT =(238.25 SQFT/ 2761.28 SQFT)100 = 8.63% TOTAL PV AREA FOR EXISTING SYSTEM =12(89.72 IN)(44.65 IN)/(144 IN^2) = 333.83 SQFT =(333.83SQFT/ 2761.28 SQFT)100 =12.08% TOTAL PV AREA FOR NEW AND EXISTING SYSTEM. (238.25+ 333.83) SQFT/ 2761.28 SQFT = 20.71% TOTAL PV AREA POPULATES 20.71% OF TOTAL PLAN VIEW AREA AND IS WITHIN THE 33% REQUIREMENT. DRIVEWAY Roof Azimuth: 297 ° Roof Tilt: 23 ° Roof Section 2 (E) GAS METER SSP SUB SERVICE PANEL Roof Azimuth: 297° Roof Tilt: 2° Roof Section 1 M METER MAIN COMBO CAL-FIRE ROOF LADDER ACCESS POINT PROPERTY LINE PROPERTY LINE PROPERTY LINEPROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E (E) SERVICE DROP M PV INTERCONNECTION POINT. LOCATION OF SUB SERVICE PANEL, AC DISCONNECT & PV LOAD CENTER MOUNTED ON EXTERIOR WALL OF A SINGLE FAMILY RESIDENCE LOCATION OF "RAPID SHUTDOWN" AC DISCONNECT NEC 690.12 ACD ACDLC LOCATION O EXISTING AC DISCONNECT & PV PRODUCTION METER PMSSP LOCATION OF METER MAIN COMBO (E) SOLAR SYSTEM CAL-FIRE ROOF LADDER ACCESS POINT CAL-FIRE ROOF LADDER ACCESS POINT CAL-FIRE ROOF LADDER ACCESS POINT PM PV PRODUCTION METER N FAIRVIEW ST (E)SHED ON PROPERTY Signed: 09/20/2023 Structural Only 1012 N King St- 101118433, 201822213/13/2024 6'6' 6' N N SCALE: 1/8" = 1'-0" PV SYSTEM MOUNTING DETAILS EVEREST ALL TILE HOOK FOR W TILE @ 72" O.C. MAX PROPOSED EVEREST CROSSRAIL RACKING PROPOSED JINKO SOLAR JKM395M-72HL-V(395W) PV SOLAR MODULES EXISTING 2 "X 4" ROOF TRUSSES @ 24"O.C. SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1012 N KING ST, SANTA ANA, CA 92706 APN:40521403 DATE:2/6/2024 ROSALES RESIDENCE License#: C-10 1053344 DESIGNER: OAV CORE ENERGY GROUP. ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 PV-2 EXISTING W TILE ROOF Roof Azimuth: 297° Roof Tilt: 2° Roof Section 1 Roof Azimuth: 297 ° Roof Tilt: 23 ° Roof Section 2 (E) SERVICE DROP EXISTING FLAT ROLLED SHINGLE ROOF QUICK MOUNT PV QMLSH-7 WITH CHEM LINK FOR FLAT ROLLED SHINGLE @ 72" O.C. MAX Signed: 09/20/2023 Structural Only 1012 N King St- 101118433, 201822213/13/2024 RO O F S L O P E 910 10 6 21 7 PV-3 D5 20 11 121413151822 PV-3 D4 3 1 54 252423 8 26 2 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1012 N KING ST, SANTA ANA, CA 92706 APN:40521403 DATE:2/23/2024 ROSALES RESIDENCE License#: C-10 1053344 DESIGNER: OAV CORE ENERGY GROUP. ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 D4 DETAIL (TRANSVERSE) NOT TO SCALE D5 DETAIL (LONGITUDINAL) NOT TO SCALE D1 RACKING DETAIL (TRANSVERSE) NOT TO SCALE D3 RACKING DETAIL (TOP) NOT TO SCALE D2 RACKING DETAIL (LONGITUDINAL) NOT TO SCALE 1. ROOF MATERIAL: W TILE 2. ROOF STRUCTURE: TRUSSES 3. ATTACHMENT TYPE: EVEREST ALL TILE HOOK 4. MODULE MANUFACTURER: JINKO SOLAR 5. MODULE MODEL: JKM395M-72HL-V(395W) 6. MODULE LENGTH: 79.06'' 7. MODULE WIDTH: 39.45" 8. MODULE WEIGHT: 49.6 LBS. 9. SEE SHEET S-1 FOR DIMENSION(S) 10. MIN. FIRE OFFSET: 18" 11. TRUSSES SPACING: 24" O.C. 12. TRUSSES SIZE: 2 "X 4" NOMINAL 13. LAG BOLT DIAMETER: 5/16 IN. 14. LAG BOLT EMBEDMENT: 2.5 IN. 15. TOTAL # OF ATTACHMENTS: 12 16. TOTAL AREA: 86.64 SQ. FT. 17. TOTAL WEIGHT: 198.40 LBS. 18. WEIGHT PER ATTACHMENT: 16.53 LBS. 19. DISTRIBUTED LOAD: 2.29 PSF 20. MAX. HORIZONTAL STANDOFF: 72 IN. 21. MAX. VERTICAL STANDOFF: LANDSCAPE: 26 IN., PORTRAIT: 43 IN. 22. STANDOFF STAGGERING: YES 23. RAIL MANUFACTURER AND MODEL (OR EQUIV.):EVEREST CROSSRAIL 24. RAIL WEIGHT: 0.436 PLF. 25. MAX. TRUSSES SPAN: 12 FT. 26. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX. PV-3 Exp: 06/30/2024 1012 N King St- 101118433, 201822213/13/2024 910 10 6 21 7 9 21 7 PV-3 D5 20 15 18 22121413 PV-3 D4 26 1 2 54 8 3 25 24 23 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1012 N KING ST, SANTA ANA, CA 92706 APN:40521403 DATE:2/23/2024 ROSALES RESIDENCE License#: C-10 1053344 DESIGNER: OAV CORE ENERGY GROUP. ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 D4 DETAIL (TRANSVERSE) NOT TO SCALE D5 DETAIL (LONGITUDINAL) NOT TO SCALE D1 RACKING DETAIL (TRANSVERSE) NOT TO SCALE D3 RACKING DETAIL (TOP) NOT TO SCALE D2 RACKING DETAIL (LONGITUDINAL) NOT TO SCALE 1. ROOF MATERIAL: FLAT ROLLED SHINGLE ROOF 2. ROOF STRUCTURE: TRUSSES 3. ATTACHMENT TYPE: QUICK MOUNT PV QMLSH-7 WITH CHEM LINK 4. MODULE MANUFACTURER: JINKO SOLAR 5. MODULE MODEL: JKM395M-72HL-V(395W) 6. MODULE LENGTH: 79.06'' 7. MODULE WIDTH: 39.45" 8. MODULE WEIGHT: 49.6 LBS. 9. SEE SHEET S-1 FOR DIMENSION(S) 10. MIN. FIRE OFFSET: 18" 11. TRUSSES SPACING: 24" O.C. 12. TRUSSES SIZE: 2 "X 4" NOMINAL 13. LAG BOLT DIAMETER: 5/16 IN. 14. LAG BOLT EMBEDMENT: 2.5 IN. 15. TOTAL # OF ATTACHMENTS: 15 16. TOTAL AREA: 151.61 SQ. FT. 17. TOTAL WEIGHT: 347.20 LBS. 18. WEIGHT PER ATTACHMENT: 23.14 LBS. 19. DISTRIBUTED LOAD: 2.29 PSF 20. MAX. HORIZONTAL STANDOFF: 72 IN. 21. MAX. VERTICAL STANDOFF: LANDSCAPE: 26 IN., PORTRAIT: 43 IN. 22. STANDOFF STAGGERING: YES 23. RAIL MANUFACTURER AND MODEL (OR EQUIV.):EVEREST CROSSRAIL 24. RAIL WEIGHT: 0.436 PLF. 25. MAX. TRUSSES SPAN: 12 FT. 26. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX. PV-3.1 Exp: 06/30/2024 1012 N King St- 101118433, 201822213/13/2024 3 (N) VISIBLE LOCKABLE 2 POLE 60A 'KNIFE' AC DISCONNECT AC DISCONNECT TO BE LOCATED WITHIN 10' OF METER M POINT OF DELIVERY AND INTERCONNECTION 100A 100A N 4 (E) GROUNDING ELECTRODE OR (UFER) EXISTING 240V/100A MAIN SERVICE PANEL SINGLE PHASE 3 40A BACKFEED BREAKER ALL EXISTING LOADS RELOCATED FROM MAIN SERVICE PANEL TO NEW SUB SERVICE PANEL (N) 240V/125A SUB SERVICE PANEL SINGLE PHASE N (N) (11) JINKO SOLAR JKM395M-72HL-V(395W) MODULES WITH (6) AP SYSTEM DS3-L 2 IN 1 MICRO-INVERTER ATTACHED TO THE BACK OF MODULE 112 1 1 PV CIRCUIT 2: 4 MODULES/PARALLEL [(2) AP SYSTEM DS3-L 2 IN 1] PV CIRCUIT 1: 7 MODULES/PARALLEL [(4) AP SYSTEM DS3-L 2 IN 1] 112 4 3 RO O F T O P GR O U N D L E V E L - HO U S E E X T E R I O R 20A 20A N 2(N) JUNCTION BOX WITH IRREVERSIBLE GROUND SPLICE NOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THE GROUNDING / BONDING, GROUND CLAMPS ARE AT EACH END OF THE EMT CONDUIT WITH THE WIRE THEN FREE AIR'D TO THE GROUND CLAMP ON THE RACKING RAIL (N) 100A PV LOAD CENTER 6 57 20A EXISTING WIRE 12 PV CIRCUIT 1: 12 MODULES/PARALLEL 12 (E) JUNCTION BOX WITH IRREVERSIBLE GROUND SPLICE (E) 12 PHONO SOLAR MODULES WITH A PS2250P(250W) ENPHASE IQ-6-60-2-US MICRO-INVERTER ATTACHED TO THE BACK OF EVERY MODULE. (E) VISIBLE LOCKABLE 2 POLE 30A 'KNIFE' AC DISCONNECT EXISTING WIRE EXISTING WIRE M (E) PV PRODUCTION METER EXISTING WIRE N N SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1012 N KING ST, SANTA ANA, CA 92706 APN:40521403 DATE:2/23/2024 ROSALES RESIDENCE License#: C-10 1053344 DESIGNER: OAV CORE ENERGY GROUP. ADDRESS:2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 E-1 DESIGN TEMPERATURES ASHRAE EXTREME LOW 2°C ASHRAE 2% HIGH 36°C PV Module Ratings @ STC Module Make/Model JINKO SOLAR JKM395M-72HL-V(395W) MODULE Max Power-Point Current (Imp)9.55A Max Power-Point Voltage (Vmp)41.4V Open-Circuit Voltage (Voc)49.5V Short-Circuit Current (Isc)10.23A Max Series Fuse (OCPD)20A Nominal Maximum Power at STC (Pmax)395W Maximum System Voltage 1500V Voc Temperature Coefficient -0.28% /°C Conduit and Conductor Schedule~(75°C Copper column) Tag Description Wire Gauge # of Conductors Conduit Type Conduit Size 1 AP SYSTEM'S AC BUS CABLE 12 AWG 2 N/A - Free Air N/A - Free Air 1 Bare Copper Ground (EGC/GEC)6 AWG 1 N/A - Free Air N/A - Free Air 2 THWN-2 (CU)10 AWG 4 EMT 3/4" 2 THWN-2 - Ground (CU)8 AWG 1 EMT 3/4" 3 3 THWN-2 (CU)8 AWG 3 EMT 3/4" THWN-2 - Ground (CU)8 AWG 1 EMT 3/4" NOTE:TOTAL AMPERAGE RATING OF ALL OVERCURRENT DEVICES SUMMED UP IN THE MAIN PANEL EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUS BAR CEC 2022 705.12(B)(3)(3) Inverter Ratings Inverter Make/Model AP SYSTEM DS3-L Max DC Volt Rating 60V Peak Output Power 768W Max Nominal Voltage 240V Max AC Current 3.2A Max OCPD Rating 20A METER # 222013506065 NOTE:EXISTING PV SYSTEM IS RSD COMPLIANT SYSTEM SUMMARY BRANCH #1 INVERTERS PER BRANCH 4 MAX AC CURRENT 12.8A MAX AC OUTPUT POWER 3072W ARRAY STC POWER 4345W ARRAY PTC POWER 4033W MAX AC CURRENT 19.20A MAX AC POWER 4608W DERATED (CEC) AC POWER 3891.84W BRANCH #2 2 6.4A 1536W SUB SERVICE PANEL 240/120V 1Ø, 3W MAIN BUSS: 125A MAX BREAKER SIZE: (125A X 1.2) - 100A = 50A4 4 THWN-2 (AL)1AWG 3 EMT 1-1/4" THWN-2 - Ground (AL)6 AWG 1 EMT 1-1/4" 1012 N King St- 101118433, 201822213/13/2024 N 1.NOT ALL PLACARDS SHOWN MAY BE REQUIRED BY LOCAL AHJ. CONTRACTOR TO VERIFY PLACARD REQUIREMENTS WITH LOCAL AHJ BEFORE INSTALLATION. 2.ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF THE CALIFORNIA ELECTRICAL CODE 3.ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTCHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHOD. 4.DIRECTORY PLACARD MARKING CONTENT AND FORMAT: RED BACKGROUND, WHITE LETTERING, MINIMUM 3/8" LETTER HIEGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. PERMANENT SIGNAGE NOTES: WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2022: 705.12(B)(3)(2) ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2022: 705.12(B)(3)(3) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 3 M (10 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. ELECTRICAL SHOCK HAZARD WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 706.15(C)(4) & 690.13(B) TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2022: 690.56(C)(2), CFC 2022: 1204.5.3 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN CAUTION: MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 19.20 AMPS 240.0 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2022: 690.54 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1012 N KING ST, SANTA ANA, CA 92706 APN:40521403 DATE:2/23/2024 ROSALES RESIDENCE License#: C-10 1053344 DESIGNER: OAV CORE ENERGY GROUP. ADDRESS:2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 E-2 1012 N KING ST WARNING! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. (N) SOLAR PANELS AND MICRO-INVERTERS ON ROOF LOCATION OF EXISTING AC DISCONNECT & PV PRODUCTION METER PV INTERCONNECTION POINT. LOCATION OF SUB SERVICE PANEL, AC DISCONNECT & PV LOAD CENTER (E) PV SYSTEM IS RSD COMPLIANT (E) SOLAR PANELS & MICRO-INVERTERS ON ROOF LOCATION OF METER MAIN COMBO N FAIRVIEW ST MAXIMUM AC OPERATING CURRENT: (NEW & EXISTING) NOMINAL OPERATING AC VOLTAGE: 30.72 AMPS 240.0 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2022: 690.54 1012 N King St- 101118433, 201822213/13/2024 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1012 N KING ST, SANTA ANA, CA 92706 APN:40521403 DATE:2/23/2024 ROSALES RESIDENCE License#: C-10 1053344 DESIGNER: OAV CORE ENERGY GROUP. ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 S-1 Exp: 06/30/2024 1012 N King St- 101118433, 201822213/13/2024 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1012 N KING ST, SANTA ANA, CA 92706 APN:40521403 DATE:2/23/2024 ROSALES RESIDENCE License#: C-10 1053344 DESIGNER: OAV CORE ENERGY GROUP. ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 S-2 Exp: 06/30/2024 1012 N King St- 101118433, 201822213/13/2024 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1012 N KING ST, SANTA ANA, CA 92706 APN:40521403 DATE:2/23/2024 ROSALES RESIDENCE License#: C-10 1053344 DESIGNER: OAV CORE ENERGY GROUP. ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 S-3 Exp: 06/30/2024 1012 N King St- 101118433, 201822213/13/2024 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1012 N KING ST, SANTA ANA, CA 92706 APN:40521403 DATE:2/23/2024 ROSALES RESIDENCE License#: C-10 1053344 DESIGNER: OAV CORE ENERGY GROUP. ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 S-4 Exp: 06/30/2024 1012 N King St- 101118433, 201822213/13/2024 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1012 N KING ST, SANTA ANA, CA 92706 APN:40521403 DATE:2/23/2024 ROSALES RESIDENCE License#: C-10 1053344 DESIGNER: OAV CORE ENERGY GROUP. ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 S-5 Exp: 06/30/2024 1012 N King St- 101118433, 201822213/13/2024 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1012 N KING ST, SANTA ANA, CA 92706 APN:40521403 DATE:2/23/2024 ROSALES RESIDENCE License#: C-10 1053344 DESIGNER: OAV CORE ENERGY GROUP. ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 S-6 Exp: 06/30/2024 1012 N King St- 101118433, 201822213/13/2024 1012 N King St- 101118433, 201822213/13/2024 09/20/2023 Design Criteria Code 2022 California Building Code (ASCE 7‐16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 15 psf V 110 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 0 psf If you have any questions on the above, please do not hesitate to call. Sincerely, Eugene Munyanziza, P.E.Signed 09/20/2023 EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 RE: Structural Certification for Installation of Residential Solar        ROGELIO ROSALES:1012 N KING ST, SANTA ANA, CA, 92706 Attn: To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the  PV system to existing roof framing.  From the field observation report, the roof is made of "W" Tile and Flat Rolled Shingle roofing over roof plywood supported by 2X4 Trusses at 24 inches. The slope of the roof was  approximated to be 23 degrees. After review of the field observation data and based on our structural capacity calculation, the existing roof  framing has been determined to be adequate to support the imposed loads without structural upgrades.  Contractor shall verify that existing framing is consistent with the described above before install. Should they  find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity  calculations were done in accordance with applicable building codes. projects@evengineersnet.com http://www.evengineersnet.com 1012 N King St- 101118433, 201822213/13/2024 Structural Letter for PV Installation Date: 09/20/2023 Job Address:1012 N KING ST SANTA ANA, CA, 92706 Job Name:ROGELIO ROSALES Job Number:230920RR Scope of Work Table of Content Sheet 2 Cover 3 Attachment U lift checks 4 Roof Framin  Check 5 Seismic Check and Scope of work Engineering Calculations Summary Code 2022 California Building Code (ASCE 7‐16) Risk category II Roof Dead Load Dr 15 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 0 psf Wind Load (component and Cladding) V 110 mph Exposure C References NDS for Wood Construction Sincerely, Signed 09/20/2023 Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV  system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's  approved installation specifications.  projects@evengineersnet.com http://www.evengineersnet.com 1012 N King St- 101118433, 201822213/13/2024 Wind Load Cont. 110 mph ASCE 7‐16 Figure 26.5‐1B C 1.0 ASCE 7‐16 Sec 26.8.2 0.85 ASCE 7‐16 Table 26.10‐1 0.85 ASCE 7‐16 Table 26.6‐1 1.00 ASCE 7‐16 Table 26.9‐1 22.31 psf 23.0 Degrees 1.5 Conservatively assuming all exposed 0.8 conservatively assuming 10 ft2 effective area Uplift (W)Zone(1,2e) Zone(2r, 2n) Zone(3e) Zone(3r) Fig. 30‐3‐2 GCp=‐1.3 ‐1.7 ‐1.7 ‐1.8 Eq. 29.4‐7 P=qh(GCp)(γE)(γa)=‐34.80 ‐45.51 ‐45.51 ‐48.18 GCp=0.6 Figure 30.3‐2 P=qh(GCp)(γE)(γa)=8.83 Equation 29.4‐7 Rafter Attachments: 0.6D+0.6W (CD=1.6)  Connection Check Attachment max. spacing= 6 ft 5/16" Lag Screw Withdrawal Value= 266 lbs/in Table 12.2A ‐ NDS 2.5 in DFL Assumed Prying Coefficient 1.4 Allowable Capacity= 760 lbs Zone Trib Width Area (ft) Uplift (lbs) Down (lbs) Zone(1,2e)6 16.5 205.8 195.3 Zone(2r, 2n)6 16.5 264.1 195.3 Zone(3e)6 16.5 264.1 195.3 Zone(3r)6 16.5 278.7 195.3 Conservative Max=278.7 < 760 CONNECTION IS OK Risk Category = KZ = Kd = Ke = 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw.  Embedment in sheading or other material does not count. II V= Exposure = 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift  governs  γE= γa=  KZt = qh= 0.00256KzKztKdKeV2= Pitch = Lag Screw Penetration projects@evengineersnet.com http://www.evengineersnet.com 1012 N King St- 101118433, 201822213/13/2024 Vertical Load Resisting System Design Roof Framing Trusses Snow Load Fully Exposed pg= 0 psf Ct =1.1 Ce =0.9 Is =1.0 pf = 0 psf pfmin. = 0.0 psf ps = 0 psf Conservatively (Cs=1) 0 plf Max Length, L = 8.0 ft (Rafter maximum Allowable Horizontal Span) Tributary Width, WT =24 in Dr = 15 psf 30 plf PvDL =3 psf 18 plf Load Case: DL+0.75(0.6W+S)   0.75(Pnet+Ps)+ Ppvcos(θ)+PDL=56 plf Mdown=298 lb‐ft Mallowable = Sx x Fb' (wind)= 456 lb‐ft > 298 lb‐ft OK Load Case: DL+S   Ps+ Ppvcos(θ)+PDL=48 plf Mdown=256 lb‐ft Mallowable = Sx x Fb' (wind)= 456 lb‐ft > 256 lb‐ft OK Load Case: DL+0.6W   Pnet+ Ppvcos(θ)+PDL=58.6 plf Max Moment, Mu=313 lb‐ft Mallowable = Sx x Fb' (wind)= 634 lb‐ft > 313 lb‐ft OK Pv max Shear= 195.3 lbs Shear, Vu=wL/2+Pv Point Load =387 lbs Max Shear, Vu=wL/2+Pv Point Load =387 lb Member Capacity DF‐L No.2  2X4 CL CF Ci Cr KF φ λ Fb =900 psi 1.0 1.5 1.0 1.15 2.54 0.85 0.8 1553 psi Fv =180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi E = 1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi Emin =580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi Depth, d = 3.5 in Width, b = 1.5 in Cross‐Sectonal Area, A = 5.25 in2 Moment of Inertia, Ixx =5.35938 in ec on Mo u us, Sxx =. Allowable Moment, Mall = Fb'Sxx =396.2 lb‐ft DCR=Mu Mall =0.65 < 1 Satisfactory Allowable Shear, Vall = 2/3Fv'A =630.0 lb DCR=Vu/Vall =0.61 < 1 Satisfactory Design Value Adjusted Value projects@evengineersnet.com http://www.evengineersnet.com 1012 N King St- 101118433, 201822213/13/2024 Siesmic Loads Check Roof Dead Load 15 psf  % or Roof with Pv 21% Dpv and Racking 3 psf Average Total Dead Load 15.6 psf Increase in Dead Load 2.1%OK  Limits of Scope of Work and Liability The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and  therefore no further seismic analysis is required. We have based our structural capacity determination on information in pictures and a drawing set titled PV plans ‐ ROGELIO ROSALES. The analysis was according to applicable building codes, professional engineering and design  experience, opinions and judgments. The calculations produced for this Structure's assessment are only for the  proposed solar panel installation referenced in the stamped plan set and were made according to generally  recognized structural analysis standards and procedures.  projects@evengineersnet.com http://www.evengineersnet.com 1012 N King St- 101118433, 201822213/13/2024 1012 N King St- 101118433, 201822213/13/2024 1012 N King St- 101118433, 201822213/13/2024 1012 N King St- 101118433, 201822213/13/2024 1012 N King St- 101118433, 201822213/13/2024 1012 N King St- 101118433, 201822213/13/2024 1012 N King St- 101118433, 201822213/13/2024 1012 N King St- 101118433, 201822213/13/2024