Loading...
HomeMy WebLinkAboutHOLD- 4621 W First St - Plan5580 SF 3568 SF 2012 SF sheet index: sheet no. issue / date: consultant: The above drawings and specifications and ideas, designs and arrange- ments represented thereby are and shall remain the property of the designer, and no part thereof shall be copied, disclosed to others or used in connection with any work or project other than the specified project for which they have been prepared and developed without the written concent of the designer. Visual contact with these plans orspecifications shall constitute conclusive evidence of acceptance of Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimen- sions and conditions on the job and this office must be notified of anyvariations from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before pro- these restrictions. ceeding with fabrication. owner information: project location: project no: phase: date: scale: drawn by: 10927 downey avenue #D downey, ca 90421 p 562.861.3883 formBstudio@gmail.com FORM STUDIO in cFORMFORM SP1 . SITE PLAN SANTA ANA, CA 4621 WEST 1ST STREET . SANTA ANA, CA 4621 WEST 1ST STREET PAUL SULLIVAN ALAN'S LANDSCAPE . NOTED 12/2/2022 . 1212076 site plan retail area storage area SCOPE OF WORK TYPE VB C-G GENERAL COMMERCIAL M= MERCANTILE CONSTRUCTION TYPE: OCCUPANCY: ZONE: 28,375.60 SQ. FT.GROSS AREA (LOT) RETAIL/ OFFICE / STORAGE AREA LEGAL DESCRIPTION ASSESSOR'S ID. No. 100-641-10 1NUMBER OF STORIES NOFIRE SPRINKLER 3,568 SQ. FT. PROJECT SUMMARY EXISTING PARKING EXISTING STANDARD SPACES 21 SPACES ( INCLUDING 2 HANDICAP SPACE) VICINITY MAP TOTAL BUILDINGS 2 STRUCTURES TOTAL: 5,580 SQ. FT. STORAGE 2,012 SQ. FT. BUILDING 2 BUILDING 1 U= STORAGE CODE COMPLIANCE REMOVE ALL NON PERMITTED STORAGE AND ROOF COVERING STRUCTURES LOWER WALL HEIGHT OF PROPERTY LINE WALLS TO MAXIMUM 10'-0" HIGH REMOVE ROLL UP DOOR AND INSTALL NEW 48" IRON GATE @ SOUTH PROPERTY LINE 11/25/23 - PLANNING FIRE PREVENTION CODE: DISABLED ACCESS: ELECTRICAL: BUILDING: 2022 EDITION OF CALIFORNIA ELEC. CODE CURRENT EDITION OF CALIFORNIA TITLE 24 2022 CALIFORNIA FIRE CODE GREEN CODE:2022 EDITION OF CALIFORNIA GREEN CODE CITY OF SANTA ANA MUNICIPAL CODES 2022 EDITION OF CALIFORNIA BUILDING CODE CODES Bldg #104118583 APPROVALS: Plng - P. Raj Bldg - T. Le HOLD- 4621 W First St12/19/2024 5580 SF 3568 SF 2012 SF sheet index: sheet no. issue / date: consultant: The above drawings and specifications and ideas, designs and arrange- ments represented thereby are and shall remain the property of the designer, and no part thereof shall be copied, disclosed to others or used in connection with any work or project other than the specified project for which they have been prepared and developed without the written concent of the designer. Visual contact with these plans orspecifications shall constitute conclusive evidence of acceptance of Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimen- sions and conditions on the job and this office must be notified of anyvariations from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before pro- these restrictions. ceeding with fabrication. owner information: project location: project no: phase: date: scale: drawn by: 10927 downey avenue #D downey, ca 90421 p 562.861.3883 formBstudio@gmail.com FORM STUDIO in cFORMFORM SP2 . . SANTA ANA, CA 4621 WEST 1ST STREET . SANTA ANA, CA 4621 WEST 1ST STREET PAUL SULLIVAN ALAN'S LANDSCAPE . NOTED 12/2/2022 . 1212076 demolisiton site plan retail area storage area 11/25/23 - PLANNING HOLD- 4621 W First St12/19/2024 sheet index: sheet no. issue / date: consultant: The above drawings and specifications and ideas, designs and arrange- ments represented thereby are and shall remain the property of the designer, and no part thereof shall be copied, disclosed to others or used in connection with any work or project other than the specified project for which they have been prepared and developed without the written concent of the designer. Visual contact with these plans orspecifications shall constitute conclusive evidence of acceptance of Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimen- sions and conditions on the job and this office must be notified of anyvariations from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before pro- these restrictions. ceeding with fabrication. owner information: project location: project no: phase: date: scale: drawn by: 10927 downey avenue #D downey, ca 90421 p 562.861.3883 formBstudio@gmail.com FORM STUDIO in cFORMFORM SP3 . WALL DETAIL SANTA ANA, CA 4621 WEST 1ST STREET . SANTA ANA, CA 4621 WEST 1ST STREET PAUL SULLIVAN ALAN'S LANDSCAPE . NOTED 12/2/2022 . 1212076 west side gate property wall elevation property wall elevationA west side gateB west side gateC enlarged plan of gateD HOLD- 4621 W First St12/19/2024 GENERAL 1. NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS TAKE PRECEDENCE OVER THESE STANDARD STRUCTURAL NOTES. DETAILS NOTES AS "TYPICAL DETAILS" SHALL BE USED WHENEVER APPLICABLE. REFER TO SPECIFICATIONS FOR INFORMATION NOT COVERED BY THESE NOTES OR DRAWINGS. 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS BEFORE STARTING WORK, AND THE ENGINEER/ARCHITECT SHALL BE NOTIFIED IMMEDIATELY, IN WRITING, OF ANY DISCREPANCIES. IN NO CASE SHALL DIMENSIONS BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THE STRUCTURAL DRAWINGS. 3. ALL OMISSIONS AND CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE STRUCTURAL DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION, AND RESOLVED WITH, THE ENGINEER BEFORE PROCEEDING WITH ANY WORK SO INVOLVED. 4. WHERE A CONSTRUCTION DETAIL IS NOT SPECIFICALLY SHOWN OR NOTES, THE DETAIL SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 5. THE CONTRACTOR SHALL DETERMINE THE LOCATION OF UTILITY SERVICES IN THE AREA TO BE EXCAVATED, BEFORE BEGINNING EXCAVATION. 6. NO PIPES, DUCTS, SLEEVES, CHASES, ETC. SHALL BE PLACED IN OR THROUGH SLABS, BEAMS, OR WALLS, NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC. EXCEPT AS INDICATED ON THE STRUCTURAL DRAWINGS. THE CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC. 7. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE 2022 CBC. 8. THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 9. RETAIN A CALIFORNIA REGISTERED CIVIL ENGINEER TO DESIGN ALL TEMPORARY BRACING, SHORING, AND SUPPORT REQUIRED DURING CONSTRUCTION. 10. INCLUDE ENGINEERING FEES, ENGINEERING DESIGN TIME AND BUILDING DEPARTMENT APPROVAL TIME IN THE COST OF PROPOSED MATERIAL ALTERNATIVES. CONTACT ENGINEER FOR FEE AMOUNT. SUBMIT MATERIAL ALTERNATIVE FOR REVIEW BEFORE CONSTRUCTION. DESIGN CRITERIA 1. VERTICAL LOADS (GRAVITY): a) DEAD LOADS: MASONRY WALL 12"..........124 PSF MASONRY WALL 8"............78 PSF METAL DOOR......................7 PSF 2. LATERAL LOADS: a) EARTHQUAKE DESIGN DATA: V = 0.15 W (ASD) (INCLUDES RHO = 1.3) SEISMIC IMPORTANCE FACTOR..........1 RISK CATEGORY.....................................II MAPPED SPECTRAL RESPONSE ACCELERATIONS Ss....................................................1.520 S1....................................................0.590 SITE CLASS..............................................D SPECTRAL RESPONSE COEFFICIENTS Sds..................................................1.170 Sd1..................................................0.850 ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE b) WIND: BASIC WIND SPEED................................95 MPH SITE EXPOSURE......................................C IMPORTANCE FACTOR...........................1.0 FOUNDATION 1. SOILS INFORMATION: BEARING PRESSURE = 1500 PSF (13 INCREASE FOR WIND OR SEISMIC) 2. BOTTOM OF FOOTING SHALL BE AT LEAST 24 INCHES BELOW THE LOWEST ADJACENT FINISHED GRADE INTO COMPETENT SOIL. 3. REFER TO AND CHECK WITH ARCHITECTURAL DRAWINGS FOR VARIOUS FLOOR SLOPES, DROPPED SLABS, DEPRESSIONS, CURBS, STEPS, WALKS DRAINS, DEPRESSED FLOOR, ETC. & DIMENSIONS NOT SHOWN. 4. NO CONCRETE SHALL BE POURED IN ANY FOUNDATION UNTIL EXCAVATION HAS BEEN INSPECTED, EXCAVATION SHALL BE KEPT FREE OF LOOSE MATERIAL AND STANDING WATER. 5. ALL SLEEVES THROUGH FOUNDATION WALLS AND UNDER FOOTING TO BE INSTALLED PRIOR TO FOUNDATION POUR. SEE TYPICAL DETAILS. 6. NO SLEEVING OF ANY GRADE BEAM WILL BE PERMITTED UNLESS SHOWN ON STRUCTURAL DRAWINGS APPROVED BY THE ENGINEER. 7. THE ENGINEER HAS NO CONTROL OR RESPONSIBILITY FOR THE DESIGN OF TEMPORARY SHORING, SCAFFOLDING, FORMING, UNDERPINNING, ETC., NOT DETAILED ON THESE PLANS. 8. ALL EXCAVATIONS SHALL BE PROPERLY BACKFILLED. DO NOT PLACE BACKFILL BEHIND RETAINING WALLS BEFORE CONCRETE (OR GROUT) HAS OBTAINED FULL DESIGN STRENGTH. CONTRACTOR SHALL BRACE OR PROTECT ALL BUILDING AND PIT WALLS BELOW GRADE FROM LATERAL LOADS UNTIL ATTACHING FLOORS ARE COMPLETELY IN PLACE AND HAVE ATTAINED FULL STRENGTH. CONTRACTOR SHALL PROVIDE FOR DESIGN, PERMITS, AND INSTALLATION OF SUCH BRACING. 9. CONTRACTOR SHALL COORDINATE ALL DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. NOTIFY STRUCTURAL ENGINEER, PRIOR TO FABRICATION OR ERECTION, WHEN DISCREPANCIES ARE FOUND. REBAR 1. NO BRICK OR POROUS MATERIAL SHALL BE USED TO SUPPORT FOOTING STEEL OFF THE GROUND. PRECAST CONCRETE ADOBES ARE APPROVED. 2. BAR REINFORCEMENT SHALL BE ASTM A615, GRADE 60. 3. BAR REINFORCEMENT THAT IS NOT WELDED SHALL BE ASTM A706, GRADE 60. WELDING OF REINFORCING BARS SHALL CONFORM TO AWS D1.4-92 AND CBC STANDARDS 19-1. E90XX ELECTRODES SHALL BE USED, SPECIAL INSPECTION IS REQUIRED FOR ALL FIELD WELDING. 4. SPLICES IN REINFORCING STEEL SHALL LAP AS FOLLOWS, UNLESS NOTES OTHERWISE: #3 THOUGH #6 =45 DIA., #7 TROUGH #11 = 56 DIA. HORIZONTAL SPLICES SHALL BE STAGGERED. NON-CONTACT SPLICES SHALL NOT BE SPACED TRANSVERSELY FARTHER APART 15THE REQUIRED LAP SPLICE LENGTH, OR 6 INCHES. 5. THE CLEAR DISTANCE BETWEEN PARALLEL BARS SHALL BE FOUR BAR DIAMETERS BUT NO LESS THAN 112" U.O.N.. IN WALLS AND SLABS OTHER THAN THE CONCRETE JOIST CONSTRUCTION, BARS SHALL BE SPACED NOT FARTHER APART THAN THREE TIMES THE WALL OR SLAB THICKNESS, NOR 18 INCHES. 6. REINFORCING STEEL SHALL HAVE A PROTECTED CONCRETE COVERING AS FOLLOWS, U.O.N.: WALL BARS BELOW GRADE: ON DIRT SIDE WHEN POURED AGAINST DIRT..... =3" ON DIRT SIDE WHEN FORMED.................... ........ =2" WALL BARS ABOVE GRADE: FOOTING PADS.................................... =3" SLABS (ON EARTH)............................=2" SLABS (LIGHT WEIGHT CONCRETE).... =34" SLABS (HARD ROCK CONCRETE).......=1" JOISTS (SIDES, TOPS, & SOFFITS)...=1" COLUMNS (TO MAIN STEEL)..............=2" BEAM, GIRDERS (SIDES, TOPS, & SOFFITS)...= 2" IN ALL OTHER CASES........................=112" 7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 AND SHALL BE LAPPED 12 INCHES MINIMUM. 8. ALL WALLS SHALL BE DOWELED TO SUPPORTING FOOTINGS, BEAMS, PADS, ETC., WITH BARS THE SAME SIZE AND SPACING AS VERTICAL BARS IN THE WALL UNLESS OTHERWISE DETAILED. ANCHORAGE OF DOWELS SHALL BE EQUIVALENT OF A BAR SPLICE. 9. DOWEL REINFORCED SLABS TO WALLS AND OTHER EDGE MEMBERS PER TYPICAL DETAILS. 10. ALL REINFORCING STEEL IS TO BE PLACED IN A RELATIVE POSITION SHOWN ON DRAWINGS. NO SPLICES IN ANY REINFORCING WILL BE PERMITTED EXCEPT THOSE SHOWN ON THE STRUCTURAL DRAWINGS. 11. REINFORCING DETAILING, BENDING, AND PLACING SHALL BE ION ACCORDANCE WITH THE CONCRETE REINFORCING STEEL INSTITUTES "MANUAL OF STANDARD PRACTICE", LATEST EDITION. 12. ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS, AND INSERTS SHALL BE WELL SECURED IN THE POSITION WITH THE WIRE POSITIONERS BEFORE PLACING CONCRETE OR GROUT. VERTICAL BARS IN THE MASONRY WALLS SHALL BE TIED IN POSITION AT THE TOP AND BOTTOM AND INTERVALS NOT EXCEEDING 200 BAR DIAMETERS. CONCRETE 1. CEMENT SHALL CONFORM TO ASTM C150, TYPE II. 2. AGGREGATES FOR NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C33. 3. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,500 PSI AT 28 DAYS: (4"MAX. SLUMP FOR FLATWORK). MIN. COMPRESSIVE STRENGTH FOR WALLS TO BE 3,000 PSI MIN. COMPRESSIVE STRENGTH FOR GRADE BEAMS TO BE 3,000 PSI MIN. COMPRESSIVE STRENGTH FOR CAISSON TO BE 3,000 PSI 4. ADMIXTURES MAY BE USED WITH PRIOR APPROVAL OF THE ENGINEER. ADMIXTURES SHALL COMPLY WITH ASTM C494 & C107 AND BE OF A TYPE THAT INCREASES THE WORKABILITY OF THE CONCRETE, BUT SHALL NOT BE CONSIDERED TO REDUCE THE SPECIFIED MINIMUM CEMENT CONTENT (CALCIUM CHLORIDE SHALL NOT BE USED). 5. NO CONDUIT PLACED IN A CONCRETE SLAB SHALL HAVE AN OUTSIDE DIAMETER GREATER THAN 13 THE THICKNESS OF THE SLAB. NO CONDUIT SHALL BE EMBEDDED IN A SLAB THAT IS LESS THAN 312" THICK. EXCEPT FOR LOCAL OFFSETS, MINIMUM CLEAR DISTANCE BETWEEN CONDUITS SHALL BE THREE DIAMETERS ON CENTER (EXCEPT IF THE CONDUIT IS PASSING THROUGH). 6. PROJECTING CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC., SHALL BE FORMED WITH 34" CHAMFERS. 7. REFER TO DRAWINGS OF OTHER DISCIPLINES FOR MOLDS, GROOVES, CLIPS, ORNAMENTS, OR GROUNDS REQUIRED TO BE CAST IN CONCRETE. 8. ALL SLABS ON GRADE SHALL HAVE CONTROL JOINTS INSTALLED TO PROVIDE APPROXIMATELY 15 FOOT SQUARES UNLESS DETAILED OTHERWISE ON THE PLANS. WHERE CONCRETE POURS ARE STOPPED, THE JOINTS SHALL BE FORMED. SEE "TYPICAL SLAB-ON-GRADE JOINT DETAIL". STRUCTURAL WOOD 1. ALL FRAMING LUMBER SHALL BE DOUGLAS FIR-LARCH GRADE MARKED BY A RECOGNIZED GRADING AGENCY (WCLIB 0R WWPA), VOLUNTARY STANDARD DOC PS20-25. LIGHT FRAMING....................CONSTRUCTION JOISTS & PLANKS.................No. 2 BEAMS & STRINGERS...........No. 1 POST AND TIMBERS..............No. 1 PARALLAM (PSL)....................2.0E WS (2900 Fb) MICROLLAM (LVL)..................2.0E WS (2900 Fb) VERTICAL STUDS: 2x4 STUDS, 8'-0" LONG..........CONSTRUCTION GRADE 2x4 STUDS, 8'-1" TO 14'-0".....No. 1 2x6 STUDS..............................No. 2 ALL OTHER LUMBER..............No. 1 STRUCTURAL LIGHT FRAMING 2. ALL SILL PLATES RESTING ON CONCRETE OR MASONRY, WHICH IS IN CONTACT WITH EARTH OR RESTING ON FOUNDATIONS SHALL BE PRESSURE TREATED DOUGLAS FIR (PT.D.F.). ALL FASTENERS SUCH AS NAILS, BOLTS, SCREWS, ANCHOR BOLTS, ETC., ATTACHING P.T.D.F. OR FIRE-RETARDANT TREADED WOOD SHALL BE HOT-DIPPED ZINC COATED GALVANIZED OR STAINLESS STEEL (ASTM A153). 3. WHERE STUD PARTITIONS JOIN CONCRETE OR MASONRY WALLS, THE END STUD WALL SHALL BE ANCHORED THERETO WITH 12" (BOLTS NEAR THE TOP & BOTTOM AND AT EACH ROW OF TIRE BLOCKING. SUCH BOLTS SHALL BE EMBEDDED IN TH EWALL NOT LESS THAN 23 OF THE WALL THICKNESS OR 8" MAX). 4. CUTTING, NOTCHING, OR BORING OF STUDS SHALL BE PERMITTED ONLY AS DETAILED OR APPROVED BY ENGINEER AND/OR PER 2022 CBC TABLE 2308.5.9 OR 2308.5.10. 5. ALL NAILING SHALL CONFORM TO 2022 CBC TABLE 2304.10.1, AND SHALL BE COMMON NAILS, UNLESS NOTED OTHERWISE ON PLANS AND DETAILS. 6. ALL BOLY HEADS AND NUTS BEARING ON WOOD SHALL HAVE STANDARD CUT WASHERS. HOLES FOR BOLTS SHALL BE BORED 116" LARGER THAN THE NOMINAL DIAMETER. BOLTS IN THE WOOD SHALL NOT BE LESS THAN 7 DIAMETERS FROM THE END AND 4 DIAMETERS FROM THE EDGE OF THE MEMBER, 7. TOP PLATES OF ALL WOOD STUD WALLS TO BE 2-2x MINIMUM (SAME WIDTH AS STUDS), LAP 48" MIN. WITH NOT LESS THAN 6-16d NAILS AT EACH LAP AND NOT MORE THAN 12" BETWEEN NAILS. 8. PLYWOOD SHALL BE APA STRUCTURAL I RATED SHEATHING WITH EXTERIOR GLUE, PER DOC PS1 OR DOC PS2. 9. PROVIDE DOUBLED JOISTS UNDER ALL PARALLEL PARTITIONS. 10. ALL LAG SCREWS TO BE PREDRILLED, DRILL DIAMETER TO BE 40 TO 70 PERCENT OF THREADED SHANK DIAMETER AND FULL DIAMETER FOR SMOOTH SHANK PORTION. 11. RE-TIGHTEN ALL ANCHOR BOLTS JUST BEFORE CLOSING IN. 12. ALL FRAMING ANCHORS, POST CAPS, BASES, HANGERS, STRAPS, ETC. SHALL BE AS MANUFACTURED BY "SIMPSON COMPANY" OR ENGINEER APPROVED EQUAL. 13. PROVIDE BLOCKING OR BRIDGING PER 2021 NDS SECTION 4.4.1 & 2022 CBC SECTION 2308.4.6 AND SECTION 2308.5.7. 14. MOISTURE CONTENT OF WOOD AT TIME OF PLACING SHALL NOT EXCEED 19 PERCENT. 15. MACHINE BOLTS SHALL BE GRADE-A CONFORMING TO ASTM A307. ANCHOR BOLTS SHALL BE ASTM F1554, GRADE 36. NUTS FOR MACHINE BOLTS AND ANCHOR BOLTS SHALL CONFORM TO ASTM A563, HEX GRADE-A. THREADED RODS SHALL CONFORM TO ASTM A36. THREADED AND NUTTED ANCHOR BOLTS SHALL BE ASTM F1554, GRADE 36. ROUNDS WASHERS SHALL CONFORM TO ASTM F436. CONCRETE MASONRY 1. CONCRETE MASONRY WALL SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF f'm = 1,500 PSI. 2. CONCRETE MASONRY UNITS SHALL BE MEDIUM WEIGHT UNITS CONFORMING TO ASTM C90, GRADE N-I, WITH MAXIMUM LINEAR SHRINKAGE OF 0.06% (1,900 PSI MIN). 3. MORTAR SHALL BE TYPE S, CONFORMING ASTM C270 (MINIMUM 1,900 PSI AT 28 DAYS). 4. GROUT SHALL BE COURSE GROUT AS DEFINES IN ASTM C476 WITH 38" MAXIMUM AGGREGATE SIZE (MIN COMPRESSIVE STRENGTH OF 2,000 PSI AT 28 DAYS). 5. FILL ALL CELLS WITH GROUT. ALL GROUT SHALL BE CONSOLIDATED WITH A MECHANICAL VIBRATOR. 6. HIGH LIFT GROUTED CONSTRUCTION SHALL CONFORM TO TMS 602/ACI 530.1/ASCE 6 SECTION 3.5 TABLE 7. SPECIAL SHALL BE PROVIDED FOR HIGH-LIFT CONSTRUCTION. 7. WHEN GROUTING IS STOPPED FOR ONE HOUR OR LONGER, HORIZ. CONSTRUCTION JOINTS SHALL BE FORMED BY STOPPING THE GROUT POUR 112" BELOW TOP OF THE UPPER MOST UNIT. 8. VERTICAL REINFORCEMENTS SHALL BE CONTINUOUS FROM FLOOR TO ROOF, UNLESS SHOWN OTHERWISE. 9. ALL HORIZONTAL REINFORCEMENTS SHALL BE PLACED IN BOND BEAM OR LINTEL BEAM UNITS. ALL BOND BEAM BLOCKS SHALL BE DEEP CUT UNITS. 10. ANCHOR BOLTS MUST BE SET WITH TEMPLATES AND HELD IN PLACE PRIOR TO GROUTING, PROVIDE AT LEAST ONE INCH OF GROUT BETWEEN ANCHOR BOLTS AND MASONRY. 11. COMPRESSIVE STRENGTH OF MASONRY MUST BE VERIFIED BY PRISM TESTING PRIOR TO AND DURING CONSTRUCTION AS SPECIFIED IN CBC SECTION 2105.2.2.2. 4 6 2 1 W E S T 1 S T S T R E E T NE W F E N C E 46 2 1 W E S T 1 S T S T R E E T SA N T A A N A , C A 9 2 7 0 3 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @ramirezstructural www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.23-101 DATE:1/18/24 RAMIREZSTRUCTURAL INC STRUCTURAL NOTES S1.0 HOLD- 4621 W First St12/19/2024 4 6 2 1 W E S T 1 S T S T R E E T NE W F E N C E 46 2 1 W E S T 1 S T S T R E E T SA N T A A N A , C A 9 2 7 0 3 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @ramirezstructural www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.23-101 DATE:1/18/24 RAMIREZSTRUCTURAL INC STRUCTURAL NOTES S1.1 HOLD- 4621 W First St12/19/2024 FOUNDATION PLAN SCALE: 18" = 1'-0" N PLAN NOTES 1. REFER TO STRUCTURAL NOTES ON SHEET S1.0 AND TYPICAL DETAILS ON SHEETS S3.0-S3.1. THESE NOTES AND DETAILS SHALL BE USED WHERE APPLICABLE WHETHER SPECIFICALLY REFERENCED ON PLANS OR NOT. 2.CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES WITH STRUCTURAL REQUIREMENTS INDICATED. REFER TO ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS. 3. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 4. NON-STRUCTURAL ELEMENTS IN NATURE SUCH AS DRAINS, SUMPS, EXTERIOR HARDSCAPE, MECHANICAL UNITS, ETC., ARE TO BE DESIGNED BY OTHERS. 5. STRUCTURAL WALLS ARE WALLS THAT RESIST GRAVITY, WIND, AND/OR SEISMIC LOADS. ALL EXTERIOR WOOD FRAMED WALLS ARE STRUCTURAL WALLS. WALLS OR PORTIONS NOT INDICATED ON THE STRUCTURAL DRAWINGS ARE PARTITION WALLS. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION AND EXTENT OF PARTITION WALLS. 6. FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. FIELD-CUT ENDS, NOTCHED, AND BORINGS SHALL BE FIELD-TREATED. FASTENERS IN TREATED WOOD SHALL BE APPROVED SILICON BRONZE/COPPER, STAINLESS STEEL, OR HOT-DIPPED ZINC COATED STEEL. 7. ANCHOR BOLTS AND HOLDOWN ANCHORS, SHALL BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION. LEGEND NEW CONCRETE FOOTING, INDICATED w/ DASHED LINES & SOLID HATCH MASONRY WALL AND PILASTERS 5S3.1 5S3.1 5 S3.1 6 S3.1 6 S3.1 4 6 2 1 W E S T 1 S T S T R E E T NE W F E N C E 46 2 1 W E S T 1 S T S T R E E T SA N T A A N A , C A 9 2 7 0 3 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @ramirezstructural www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.23-101 DATE:1/18/24 RAMIREZSTRUCTURAL INC FOUNDATION PLAN S2.0 HOLD- 4621 W First St12/19/2024 AT INTERIOR WEAKENED PLANE JOINT: SAWCUT SLAB AS SOON AS POSSIBLE AFTER POUR (AVOID SPALLING CORNERS) REINF. PER PLAN CLEAN GRAVEL PER PLAN VAPOR BARRIER PER PLAN PAD GRADE AT GARAGE/EXTERIOR WEAKENED PLANE JOINT: SAWCUT SLAB AS SOON AS POSSIBLE AFTER POUR (AVOID SPALLING CORNERS) REINF. PER PLAN SAND PER PLAN PAD GRADE 134 578 911 SLAB ON GRADE STEP IN SLAB SLAB EDGE FINISH GRADE TURN TRANSVERSE REINF. & PROVIDE DOUBLE CONT. REINF. AT EDGE STEPPING CONTINUOUS FOOTING FOOTING AT PIPE/CONDUIT REINFORCEMENT HOOKS & BENDSTIES & STIRRUPS STEP DOWNSTEP UP FOOTING INTERSECTIONS ENDINTERSECTIONCORNER TOP REINF. CONT. THRU OPTIONAL C.J. REINF. SAME SIZE & SPACING AS FOOTING REINF. FOOTING STEP AS REQD. FOOTING STEP AS REQD. REINF. SAME SIZE & SPACING AS FOOTING REINF. TOP BARS (WHERE OCCURS)2 #5 U.O.N. STD. HOOK ALL CORNERS & INTERSECTIONS SHALL HAVE 2 #5 VERTICAL U.O.N. PROVIDE OUTSIDE CORNER LAP BARS PROVIDE STD. 90° HOOK AT INSIDE BARS NOTE: PLACE CONCRETE FILL AROUND SLEEVES BEFORE POURING FOOTING PADS. FILL SHALL BE SAME WIDTH AS FOOTING AND FULL DEPTH OF PIPE TRENCH. NOTE: WHERE PIPES ARE MORE THAN 2'-0" BELOW OF FOOTING. STEP FOOTING DOWN PER TYPICAL FOOTING STEP DETAILBACKFILL TRENCH AND RECOMPACTION TO 90 PERCENT COMPACTION NO DIGGING FOR PIPE TRENCH PARALLEL TO FOOTING BELOW THIS LINE (STEP FTG. DOWN AS REQ'D) TRENCH FOOTING NO PIPES TO BE PLACED WITHIN THIS HEIGHT SLEEVE: I.D. SLEEVE SHALL BE 2" (MIN.) LARGER THAN O.D. OF PIPE DIA. = 6 db (FOR #3 THRU #8) DIA. = 8 db (FOR #9, #10 & #11) DIA. = 10 db (FOR #14 & #18) (db = BAR DIAMETER) NOTE: BEND 4 db MINIMUM FOR STIRRUPS & TIES. NOTE: FOR SIZE & SPACING OF ALL TIES AND STIRRUPS, REFER TO SCHEDULE AND/OR TYPICAL DETAILS. ALTERNATE POSITION OF 135° AND 90° BENDS TYPICAL ALTERNATE POSITION OF SUCCESSIVE TIE SPLICES TYPICAL. DIMENSION "a" FOR #3 TIES = 5" FOR #4 TIES = 5 12" FOR #5 TIES = 6" TYPICAL COLUMN TIES BEAM STIRRUPS OPTIONALDUCTILE A B C D E CONC. & MASONRY OPENING ADDITIONAL #4 @ 16" PER JAMB DETAIL BELOW WHERE MIN. DIST. CANNOT BE OBTAINED, EXTEND BARS AS FAR AS POSSIBLE AND HOOK. THESE BARS NOT TO BE USED WHERE LARGER LINTEL OR JAMB BARS ARE SHOWN ON PLAN NOTE: TRIM BARS ARE IN ADDITION TO TYP. WALL REINFORCING. 1-#6 @ 8" WALLS AND 2-#6 @ 12" WALLS AT OPENINGS LESS THAN 8'-0". 1-#7 @ 8" WALLS AND 2-#7 @ 12" WALLS AT OPENINGS FROM 8'-0" TO 14'-0". 12" MASONRY LINTEL 8" MASONRY LINTEL (SILLS SIMILAR) 21 2 " C L R . 2" C L R . 48 D I A . 2- #6 MIN. EA END 48 DIA. LAP**1-#6 MIN. EA END#4 @ 16" "L" = FROM 2'-8" TO 6'-0" ADD #4 @ 16" 2'-6"4" CLR. 8" MASONRY JAMB 12" & 16" MASONRY JAMB ADD #4 @ 16" 2'-6"4" CLR. **WHERE "L" IS LESS THAN 2'-8" USE ONE PIECE REBAR PER COLUMN TIE DETAIL. WHERE "L" IS GREATER 6'-0" USE TYPICAL JAMB DETAIL.THAN 12" & 16" MASONRY PIER JAMB AND SILL REINF. SAME AS ABOVE #4 @ 16" 48 DIA. LAP** "L" = FROM 2'-8" TO 6'-0" 48 DIA. 64 D I A . JAMB REINF. FROM BELOW, WHERE OCCURRING. MATCH REINF. ABOVE **WHERE "L" IS LESS THAN 2'-8" USE ONE PIECE REBAR WITH STANDARD HOOK AT BOTH ENDS. WHERE "L" IS GREATER THAN 6'-0" USE TYPICAL JAMB DETAIL. 8" MASONRY PIER NOTE: ADD VERTICAL JAMB BAR AT ALL END OF WALLS POUR LINE CONC. BLK. INTERSECTIONS 2-#5 U.O.N.40 DIA. 2'-0" MIN. TYP. 40 DIA. 2'-0" MIN. TYP. STD. HOOKS ALTERNATE CORNER BARS PROVIDE CORNER LAB BARS ALL CORNERS & INTERSECTIONS SHALL HAVE 2-#5 VERTICAL U.O.N. CORNER INTERSECTION END (HORIZONTAL REINF. AT CENTER OF WALL) 4 6 2 1 W E S T 1 S T S T R E E T NE W F E N C E 46 2 1 W E S T 1 S T S T R E E T SA N T A A N A , C A 9 2 7 0 3 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @ramirezstructural www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.23-101 DATE:1/18/24 RAMIREZSTRUCTURAL INC TYPICAL DETAILS S3.0 HOLD- 4621 W First St12/19/2024 13 57 11 8 1112 34 6 5-#4 CONT. (MIN. LAP=2'-6") 2' - 6 " M I N . (B R G . D E P T H ) 24 " M I N . 3" CL R . TY P 8" CON. BLOCK WALL w/ #4 VERT. @16" O.C. (CTRD) & #4 HORIZ. @ 24 O.C. (CTRD) (SOLID GROUT)9' - 0 " MA X . 4'-0" MIN. 1' - 0 " HARDSCAPE OR PAVING (WHERE OCCURS) #4 @4" O.C. 30 " M I N . LA P 12" SQ. CONC. BLOCK PILASTER (SOLID GROUT) (4)-#4 VERTICAL (ONE EA. CORNER #3- TIES @8" O.C. 9' - 0 " MA X . 12" MASONRY COLUMN (3)-#4 EA. WAY T&B 2'-0" 3" CL R . TY P 2' - 6 " M I N . (B R G . D E P T H ) 24 " M I N . 2" CLR. 2 24 " M I N . CORRUGATED METAL DECKING w/ SIMPSON SELF-DRILLING METAL SCREW AT EA. FLUE TO HSS COLUMN TYP. HSS2x1x 1 4" COLUMN @ 8'-0" O.C. EMBEDDED INTO MASONRY METAL DECKING HT. VARIES (9'-0" CMU DESIGN CONDITION) NOTE: WALL CONSTRUCTION IS EXITING. THEREFORE, CONTRACTOR TO FIELD VERIFY FIELD CONDITIONS TO MATCH THESE DETAILS. NOTIFY E.O.R. IMMEDIATELY IF ANY DISCREPANCIES ARE ENCOUNTERED. NOTE: PILASTER CONSTRUCTION IS EXITING. THEREFORE, CONTRACTOR TO FIELD VERIFY FIELD CONDITIONS TO MATCH THESE DETAILS. NOTIFY E.O.R. IMMEDIATELY IF ANY DISCREPANCIES ARE ENCOUNTERED. 4 6 2 1 W E S T 1 S T S T R E E T NE W F E N C E 46 2 1 W E S T 1 S T S T R E E T SA N T A A N A , C A 9 2 7 0 3 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @ramirezstructural www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.23-101 DATE:5/28/24 RAMIREZ STRUCTURAL INC TYPICAL DETAILS S3.1 HOLD- 4621 W First St12/19/2024 STRUCTURAL CALCULATIONS FOR 4621 WEST 1ST STREET NEW FENCE 4621 WEST 1ST STREET SANTA ANA, CA 92703 ENGINEERED BY: JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 HOLD- 4621 W First St12/19/2024 DESIGN CRITERlA 1. SOIL BEARING PRESSURE: 1500 PSF 2. FOOTING MINIMUM BEARING DEPTH: 18" 3. CONCRETE MIN. COMPRESSIVE STRENGTH: 2500 PSI 4. REINFORCING SHALL CON FORM TO: ASTM 615, GRADE 60 5. ALL LUMBER SHALL BE GRADE MARKED DOUGLAS FIR. a. LIGHT FRAMING (CONSTRUCTION) b. JOIST &PLANKS (N0 .2) c. BEAMS & STRINGERS (NO.1) d. POSTS & TIMBERS (N0.1) 6. PLYWOOD SHALL CONFORM TO: PS 1-95, STRUCTURAL 1 7. ALL MATERIALS & WORKMANSHIP TO CONFORM TO 2022 CALIFORNIA BUILDING CODE. HOLD- 4621 W First St12/19/2024 DESIGN LOADS MASONRY WALL 12"124.0 PSF MASONRY WALL 8"78 PSF METAL DOOR 7.0 PSF HOLD- 4621 W First St12/19/2024 HOLD- 4621 W First St12/19/2024 ASCE Hazards Report Address: 4621 W 1st St Santa Ana, California 92703 Standard:ASCE/SEI 7-22 Latitude:33.745651 Risk Category:II Longitude:-117.930781 Soil Class:Default Elevation:70.6350982412942 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph 300-year MRI 89 Vmph 700-year MRI 95 Vmph 1,700-year MRI 101 Vmph 3,000-year MRI 106 Vmph 10,000-year MRI 115 Vmph 100,000-year MRI 132 Vmph 1,000,000-year MRI 151 Vmph Data Source: ASCE/SEI 7-22, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Thu Jan 18 2024 Page 1 of 5https://ascehazardtool.org/Thu Jan 18 2024 HOLD- 4621 W First St12/19/2024 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-22 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Values for 10-year MRI, 25-year MRI, 50-year MRI and 100-year MRI are Service Level wind speeds, all other wind speeds are Ultimate wind speeds. Site is not in a hurricane-prone region as defined in ASCE/SEI 7-22 Section 26.2. Page 2 of 5https://ascehazardtool.org/Thu Jan 18 2024 HOLD- 4621 W First St12/19/2024 PGA M : 0.68 S MS : 1.76 S M1 : 1.27 S DS : 1.17 S D1 : 0.85 T L : 8 SS : 1.52 S1 : 0.59 VS30 : 260 Seismic Design Category: D Multi-Period Design Spectrum S (g) vs T(s)a Multi-Period MCE SpectrumR S (g) vs T(s)a Two-Period Design Spectrum S (g) vs T(s)a Two-Period MCE SpectrumR S (g) vs T(s)a Design Vertical Response Spectrum Vertical ground motion data has not yet been made available by USGS. MCE Vertical Response SpectrumR Vertical ground motion data has not yet been made available by USGS. Seismic DefaultSite Soil Class: Results: Page 3 of 5https://ascehazardtool.org/Thu Jan 18 2024 HOLD- 4621 W First St12/19/2024 Data Accessed: Thu Jan 18 2024 Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-22 and ASCE/SEI 7-22 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-22 Ch. 21 are available from USGS. Page 4 of 5https://ascehazardtool.org/Thu Jan 18 2024 HOLD- 4621 W First St12/19/2024 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 5 of 5https://ascehazardtool.org/Thu Jan 18 2024 HOLD- 4621 W First St12/19/2024 INPUT DATA Ex osure cate or (B, C or D)= C Im ortance factor, 73, (0.87, 1.0 or 1.15)I = 1.00 Cate or II Basic wind speed (3 sec. gust wind) V = 95 mph Topographic factor (Sec.6.5.7.2, pg 26 & 45)Kzt = 1 Flat Height of top h = 10 ft Vertical dimension for wall, s = h s = 10 ft Horizontal dimension B = 125.8333 ft Dimension of return corner L = 0.6666 ft DESIGN SUMMARY Max horizontal wind pressure p =18 psf Max total horizontal force at centroid of base F = 23.21 kips Max bending moment at centroid of base M = 127.66 ft-kips Max torsion at centroid of base T = 584.13 ft-kips ANALYSIS Velocity pressure qh = 0.00256 Kh Kzt Kd V2 I =16.69 psf where: qh = velocity pressure at mean roof height, h. (Eq. 6-15, page 27) Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 6-3, Case 1,pg 79)= 0.85 Kd = wind directionality factor. (Tab. 6-4, for building, page 80)= 0.85 h = height of top = 10.00 ft Wind Force Case A: resultant force though the geometric cente (Sec. 6.5.14 & Fig. 6-20) p = qh G C ==18 psf F = p As =23.21 kips M = F (h - 0.5s) for sign, F (0.55h) for wall =127.66 ft-kips T ==0.00 ft-kips where: G = gust effect factor. (Sec. 6.5.8, page 26).= 0.85 C = net force coefficient. (Fig. 6-20, page 73)1.30 As = B s = 1258.3 ft2 Wind Force Case B: resultant force at 0.2 B offset of the geometric cente (Sec. 6.5.14 & Fig. 6-20) p = Case A =18 psf F = Case A =23.21 kips M = Case A =127.66 ft-kips T = 0.2 F B =584.13 ft-kips Wind Force Case C: resultant force different at each region (Sec. 6.5.14 & Fig. 6-20) p = qh G C F =  p As M =  [ F (h - 0.5s) for sign, F (0.55h) for wall ] T =  Ts s Distance C Pi Asi Fi Mi Ti 0 (ft) (Fig.6-20)s ft2 ki s ft-ki s ft-ki s 0.91 1 10.0 0.726 10 100 1.03 5.66 59.62 0.87 2 20.0 0.698 10 100 0.99 5.45 47.49 0.84 3 30.0 0.671 10 100 0.95 5.24 36.12 0.81 4 40.0 0.644 9 100 0.91 5.03 25.52 0.77 5 50.0 0.617 9 100 0.88 4.82 15.69 0.61 10 100.0 0.484 7 100 0.69 3.78 -8.31 0.61 B 125.8 0.484 7 258.3333 1.78 9.77 -88.78 7.23 39.74 87.35 Wind Analysis for Freestanding Wall & Sign Based on ASCE 7-22 HOLD- 4621 W First St12/19/2024 CONCRETE BLOCK FENCE WALL w/ ECCENTRIC FTG. wall= 8 tw= 7.625 in h1=9 ft (wall height) w1= 78 psf f'm= 1500 psi As= 0.196 in^2 bar h2=1 ft (fence)w2= 5 psf Fy= 60000 psi As/ft= 0.147 in^2/ft df=2 ft (depth of ftg)BAR= #4 d= 3.8125 in tf=2 ft (ftg thickness)s=32 in wf=4 ft (ftg width)LOCATION=CTRD qa= 1500 psf (15.4.2 Rigid Nonbuilding Structures) ap=1.00 SDS= 1.170 I=1.0 Wp= 78 psf Wf= 5 psf 0.35 Wp Fp=0.30 SDS I Wp= Fp=29.1 psf =2.00 ft =4.0 ft =2.00 ft =0.00 ft =1.00 ft SEISMIC FORCE INPUT =9.00 fth1 wf tfd h2 HOLD- 4621 W First St12/19/2024 Cantilevered Retaining Wall LIC# : KW-06020349, Build:20.24.03.04 Ramirez Structural Inc (c) ENERCALC INC 1983-2023 DESCRIPTION:W1 Project File: 24-111 4621 W 1ST ST.ec6 Project Title: Engineer: Code References 0.50 9.50 0.00 6.00 1,500.0 35.0 0.0 100.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water table above =ft = = 110.00=pcf = Soil Density, Heel = Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe 110.00 pcf Footing||Soil Friction =0.400 Soil height to ignore for passive pressure =12.00 in Equivalent Fluid Pressure Method bottom of footing Surcharge Loads Adjacent Footing Load Load Type 0.0 Lateral Load =29.1 #/ft 0.0 0.0 0.0 0.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load (Service Level) =lbs Footing Type Spread Footing Surcharge Over Toe psf Footing Width =0.00 ft...Height to Top =10.00 ft Eccentricity =0.00 in...Height to Bottom =0.50 ft Used To Resist Sliding & Overturning Used for Sliding & Overturning = (Strength Level) = HOLD- 4621 W First St12/19/2024 Cantilevered Retaining Wall LIC# : KW-06020349, Build:20.24.03.04 Ramirez Structural Inc (c) ENERCALC INC 1983-2023 DESCRIPTION:W1 Project File: 24-111 4621 W 1ST ST.ec6 Project Title: Engineer: Design Summary Wall Stability Ratios Overturning =2.61 Global Stability =2.71 OK Sliding =2.90 OK Total Bearing Load =2,188 lbs ...resultant ecc.=5.03 in Eccentricity within middle third Soil Pressure @ Toe =871 psf OK Soil Pressure @ Heel =199 psf OK Allowable =1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe =1,220 psf ACI Factored @ Heel =278 psf Footing Shear @ Toe =5.1 psi OK Footing Shear @ Heel =0.0 psi OK Allowable =82.2 psi Sliding Calcs Lateral Sliding Force =385.8 lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 855.7 262.5 == 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type = Stem Construction 2nd Bottom Stem OK Shear.....Actual =9.00ft 0.00 Wall Material Above "Ht"=Fence Masonry Thickness =8.00 Rebar Size =#4 Rebar Spacing =16.00 Rebar Placed at =Edge Design Data fb/FB + fa/Fa =0.702 Total Force @ Section =lbs Moment....Actual =ft-# Moment.....Allowable =3,309.4ft-# =psi Shear.....Allowable =69.7 Wall Weight =84.0psf Rebar Depth 'd'=in 5.25 Masonry Data f'm =1,500psiFy=psi 60,000 Solid Grouting =Yes Modular Ratio 'n'=21.48 Equiv. Solid Thick.=7.63 Concrete Data f'c =psi Fy = Masonry Design Method SD= Load Factors Building Code Dead Load 1.200 Live Load 1.600 Earth, H 1.600 1.600 Seismic, E 1.000 =449.3lbsStrength Level Service Level Strength Level =2,323.3ft-# Service Level Strength Level =4.9psi Design Method =SD SD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Anet (Masonry)=91.50in2 HOLD- 4621 W First St12/19/2024 Cantilevered Retaining Wall LIC# : KW-06020349, Build:20.24.03.04 Ramirez Structural Inc (c) ENERCALC INC 1983-2023 DESCRIPTION:W1 Project File: 24-111 4621 W 1ST ST.ec6 Project Title: Engineer: 3.33 0.67 24.00 Footing Torsion, Tu = = ft-lbs Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 =3,000 psi Toe Width =ft Heel Width = Footing Thickness =in 4.00= Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00 pcfFooting Concrete Density Fy =60,000 psi Footing Design Results Key: = No key defined Toe:#4@ 4.62 in, #5@ 7.17 in, #6@ 10.18 in, #7@ 13.88 in, #8@ 18.28 in, #9@ 23.14 in, #10@ 29.39 in Flush heel condition. No reinforcing required. =None Spec'd = = = = = 1,220 5,321 2,603 2,719 5.14 44.06 Heel: 0 0 0 0.00 43.37 Heel psf ft-# ft-# ft-# psi psi = Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 4 @ 4.00 in If one layer of horizontal bars: 2.07 0.52 #4@ 4.63 in in2 in2 / supplemental design for footing torsion. HOLD- 4621 W First St12/19/2024 Cantilevered Retaining Wall LIC# : KW-06020349, Build:20.24.03.04 Ramirez Structural Inc (c) ENERCALC INC 1983-2023 DESCRIPTION:W1 Project File: 24-111 4621 W 1ST ST.ec6 Project Title: Engineer: Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment Item Force ft-#lbs ftft ft-# =Surcharge over Heel = Surcharge Over Heel = = Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem = = = 183.3 1.67 305.5= = = Stem Weight(s) = 756.0 3.67 2,771.7 Earth @ Stem Transitions =Footing Weight = 1,199.9 2.00 2,399.6 Key Weight = Added Lateral Load lbs =2,095.4 Vert. Component Total = 2,139.2 276.5 7.25 2,004.3 5,476.9 * Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =385.8 O.T.M. = Resisting/Overturning Ratio =2.61 Vertical Loads used for Soil Pressure =2,187.5 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. 0.0 4.00 4.00 0.0 0.0 Water Table Buoyant Force = HL Act Pres (ab water tbl) HL Act Pres (be water tbl) 109.4 0.83 91.1 Hydrostatic Force Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.061 in because the wall would then tend to rotate into the retained soil. HOLD- 4621 W First St12/19/2024 Cantilevered Retaining Wall LIC# : KW-06020349, Build:20.24.03.04 Ramirez Structural Inc (c) ENERCALC INC 1983-2023 DESCRIPTION:W1 Project File: 24-111 4621 W 1ST ST.ec6 Project Title: Engineer: Rebar Lap & Embedment Lengths Information Stem Design Segment: Bottom Stem Design Height: 0.00 ft above top of footing K_cover=2.125, K_spacing=16, K_diam=4.5, and K_min=2.125 Lap Splice length for #4 bar specified in this stem design segment (25.4.2.4a) =23.69 in 23.69 in 5.63 in 0.1500 in2/ft 0.1021 in2/ft HOLD- 4621 W First St12/19/2024 Cantilevered Retaining Wall LIC# : KW-06020349, Build:20.24.03.04 Ramirez Structural Inc (c) ENERCALC INC 1983-2023 DESCRIPTION:W1 Project File: 24-111 4621 W 1ST ST.ec6 Project Title: Engineer: HOLD- 4621 W First St12/19/2024 Cantilevered Retaining Wall LIC# : KW-06020349, Build:20.24.03.04 Ramirez Structural Inc (c) ENERCALC INC 1983-2023 DESCRIPTION:W1 Project File: 24-111 4621 W 1ST ST.ec6 Project Title: Engineer: HOLD- 4621 W First St12/19/2024 Masonry Column LIC# : KW-06020349, Build:20.23.12.07 Ramirez Structural Inc (c) ENERCALC INC 1983-2023 DESCRIPTION:C1 Project File: 24-111 4621 W 1ST ST.ec6 Project Title: Engineer: Printed: 18 JAN 2024, 5:57PM Masonry Column LIC# : KW-06020349, Build:20.23.12.07 Ramirez Structural Inc (c) ENERCALC INC 1983-2023 DESCRIPTION:C1 Project File: 24-111 4621 W 1ST ST.ec6 Project Title: Engineer: Printed: 18 JAN 2024, 5:57PM .Code References Calculations per TMS 402-16, IBC 2021, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Material Properties Analysis Settings psi E - Rebar =29,000.0 ksi Tie Bar Size Tie Bar Spacing =8.0 in Column Data =Column width along X-X =11.625 in 11.625 in Column depth along Y-Y Longitudinal Bar Size =4.0 M factor for Strength Design=0.90 # =Bars per side at +Y & -Y 2 =Bars per side at +X & -X 2 inCover from ties =2.0 inActual Edge to Bar Center 2.625= 3#=psi 32000= 60000= 1,500.0 Fs - Allowable = Fy - Yield Grade 60Rebar Grade 130.0 =900.0 Analysis Method pcf Overall Column Height =Top Free, Bottom FixedEm = f'm * Construction Type =9.0 ft= 75.0 Solid Grouted Hollow Concrete Masonry = Column Density = End Fixity Condition psiF'm Fr - Rupture psi =Strength Design Y-Y (depth) axis : X-X (width) axis : Fully braced against buckling ABOUT X-X Axis Fully braced against buckling ABOUT Y-Y Axis Brace condition for deflection (buckling) along columns : .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 1,098.02 lbs * Dead Load Factor AXIAL LOADS . . . BENDING LOADS . . . Lat. Uniform Load creating Mx-x, E = 0.0460 k/ft .DESIGN SUMMARY Pu 0.9 * Pn Mu-x 0.9 * Mn-x : ( TMS 402-16, Sec 5.3.1.3 )( TMS 402-16, Sec. 9.3.4.1.1 ) ( TMS 402-16, Sec. 5.3.1.1(b) ) Governing K * Lu / Dimension <= 30( TMS 402-16, Sec. 5.3.1.1(a) ) 3.356 Ry 3.356 Rx PASS Maximum SERVICE Load Reactions . . Top along X-X 0.000 k Bottom along X-X 0.414 k Maximum SERVICE Load Deflections . . . 0.169 Load Combination : 1 Along x-x Location of max.above base 0.032 +0.90D+E in at 9.000 ft above base for load combination :E Only At maximum location values are . . . 0.000 ft Bending Check Results Maximum Bending Stress Ratio = k-ft Reinforcing Area Check Pa = 0.80 [ 0.80 f'm (An - Ast) + FyAst) * [1-(h/(140*r))^2]As : Actual Reinforcement 0.800 Compressive Strength 0.338 Min. Side Dim. >= 8" Min. Tie Dia. = 1/4", # 3 bar provided Max Tie Spacing = 8.00 in, Provided = 8.00 in PASS Dimensional Checks PASS Check Column Ties (TMS 402-16, Sec 5.3.1.4) 5.406 150.630 kPASS Min: 0.0025 * An Max: 0.04 * An k k-ft 0.988 5.879 -1.863 11.050 k .Load Combination Results Load Combination Maximum Moments Stress Ratio Location Actual AllowStatusActualAllow Maximum Bending Stress Ratios Maximum Axial Load +1.20D PASS 150.6260.0 1.318 0.0 k-ftkk k-ftft0.008736 7.908 +0.90D PASS 150.6260.0 0.9882 0.0 k-ftkk k-ftft0.006552 7.908 +1.20D+E PASS 8.0720.0 1.318 1.863 k-ftkk k-ftft0.1638 11.351 +0.90D+E PASS 5.8790.0 0.9882 1.863 k-ftkk k-ftft0.1685 11.050 .Note: Only non-zero reactions are listed. Load Combination Y-Y Axis Reaction Axial Reaction @ Base @ Top @ Base Maximum Reactions D Only k 1.098 kk +0.60D k 0.659 kk +D+0.70E 0.290 k 1.098 kk +D+0.5250E 0.217 k 1.098 kk HOLD- 4621 W First St12/19/2024 Masonry Column LIC# : KW-06020349, Build:20.23.12.07 Ramirez Structural Inc (c) ENERCALC INC 1983-2023 DESCRIPTION:C1 Project File: 24-111 4621 W 1ST ST.ec6 Project Title: Engineer: Printed: 18 JAN 2024, 5:57PM Masonry Column LIC# : KW-06020349, Build:20.23.12.07 Ramirez Structural Inc (c) ENERCALC INC 1983-2023 DESCRIPTION:C1 Project File: 24-111 4621 W 1ST ST.ec6 Project Title: Engineer: Printed: 18 JAN 2024, 5:57PM Note: Only non-zero reactions are listed. Load Combination Y-Y Axis Reaction Axial Reaction @ Base @ Top @ Base Maximum Reactions +0.60D+0.70E 0.290 k 0.659 kk E Only 0.414 k kk .Maximum Deflections for Load Combinations Max. Y-Y DeflectionLoad Combination Distance D Only 0.0000 ftin0.000 +0.60D 0.0000 ftin0.000 +D+0.70E 0.0221 ftin9.000 +D+0.5250E 0.0166 ftin9.000 +0.60D+0.70E 0.0221 ftin9.000 E Only 0.0313 ftin8.940 ..Cross Section Interaction Diagram HOLD- 4621 W First St12/19/2024 Load Case EQ 16-12.1 2019 CBC, Section 16.5.3.1 Basic Load Comb. Eq 16-12 load D Lr L E W factor 1.2394 0 0 0.7 0 Overturning Moment Force height h Brg. Depth D F x ( h+ D) 0.046 9 2 0.506 0 0 2 0 0 0 2 0 0 0 2 0 Mot= 0.506 k-ft Load Factor * Service Mot= 0.506 x 0.7 x 0.75 =0.27 k-ft * 25 percent reduction in Overturning moment at soil-foundation interface per ASCE7-16, Section 12.13.4 Axial Load D Lr L trib1 trib2 D Lr L 1.098 0 0 1 1 1 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 footing 225 0 0 2 2 900 0 0 Total= 901 0 0 D Lr L factor 1.2394 0 0 Load 901 0 0 Total 1117 0 0 =1.12 kips Input Footing dimensions Width B= 2 feet Footing extension Lext=0 L= 2 feet Thickness T= 1.5 feet Footing Depth D= 2 feet Allowable soils pressure Qa= 1.50 ksf Overturning Moment Mot=0.27 k-ft Footing Length Unit Loads Total Loads Footing with Overturnin HOLD- 4621 W First St12/19/2024 Output Aftg=4.0 ft.^2 Footing Section Modulus S=1.3 ft.^3 Total Axial Load Ptotal=1.12 kips Resisting Moment Mr=1.12 k-ft 1.12 - 0.27 = 0.76 ft. x 3 =2.29 feet 1.12 Therefore…….Trapazoidal Soil Distribution q= 0.478 ksf < Qa= 1.50 ksf OK (.32) 0.02 ks USE:2.00 FT. WIDE x 2.00 FT. LONG x 18 IN. THK. FTG. HOLD- 4621 W First St12/19/2024 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM HOLD- 4621 W First St12/19/2024 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs HOLD- 4621 W First St12/19/2024