ELECTROMECHANICAL GATE
61'-1"
17'-0"
20
'
-
2
"
MAN DOOR EGRESS
20'-0"
17
'
-
0
"
9'
-
6
"
(E) ADA
PARKING
SPACE
SIGNAGE
PA
TH
O
F
TR
A
VE
L
NO
P
A
R
K
I
N
G
NO PARKING
WORK IS LIMITED TO THIS AREA
25'-0"
FIRE HYDRANT
W/ PROTECTIVE
CURB
FIRE ACCESS ROADWAY
8'
-
6
"
18'-0"
25
'
-
0
"
60
"
12"
48
"
CBC 11B-404.2.4 (Door/Gate
Maneuvering Clearances).
10.
9.
11.
1.
2.
3.
4.
5.72
'
-
6
"
6.
7.
8.
EXISTING
LINE
PROPERTY
BUILDING
JO
B
A
D
D
R
E
S
S
AS NOTED
a 12/16/20 BZ
b 2/26/25 BZ
DATE
SCALE
DRAWN
JOB
SHEET
REVISIONS BY
SHEET TITLE
PL
A
N
C
H
E
C
K
/
P
E
R
M
I
T
29
0
3
S
H
A
L
L
A
D
A
Y
S
T
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
5
0000
B.Z.
09.05.2024
(714) 721 - 4067
permitsync@gmail.com
PREPARED BY
BRYAN ZAMUDIO
09.01.2024
LE
G
A
L
D
E
S
C
R
I
P
T
I
O
N
AP
N
:
TR
A
C
T
:
LO
T
:
41
1
-
0
4
1
-
0
4
7
1
1
BL
K
:
B
8
/
B
ENGINEERING
REGISTEREDPROFESSIONALENGINEER
STATEOF CALIFORNIA
JOHN L.TIONGCOC70915
C I V IL
c 3/18/25 BZ
SCOPE OF WORK
DIRECTORY
PROPERTY
OWNER:
OCCUPANCY GROUP:
B, F-2, S-2
USE : WAREHOUSE,
OFFICE, AND DISTRIBUTION
CENTER
CONSTRUCTION TYPE: V-B
NUMBER OF STORIES: 1
HEIGHT OF BUILDING:
FIRE SPRINKLERED:
NO. OF PARKING SPACES: 10
ADA PARKING SPACE: 1
BUILDING DATA
ALL WORK SHALL COMPLY WITH:
2022 CALIFORNIA BUILDING CODE
2022 CALIFORNIA RESIDENTIAL CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA PLUMBING CODE
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA ENERGY CODE
2022 CALIFORNIA GREEN BUILDING CODE
2022 CALIFORNIA ENERGY STANDARDS
AND LOCAL ORDINANCES
SITE PLAN SCALE
1/16" = 1'-0"
LEGALIZING AS BUILT SLIDING GATE
AS PER:
1. Wall and fence requirements in the
industrial and commercial zones.
SAMC 41-610.5
ENGINEER:
THE DISCHARGE OF POLLUTANTS TO ANY STORM
DRAINAGE SYSTEM IS PROHIBITED. NO SOLID
WASTE, PETROLEUM BY-PRODUCTS, SOIL
PARTICULATE, CONSTRUCTION WASTE MATERIALS,
OR WASTEWATER GENERATED ON CONSTRUCTION
SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE
PLACED, CONVEYED OR DISCHARGED INTO THE
STREET, GUTTER OR STORM DRAIN SYSTEM
TABLE OF CONTENTS
CONTENTS
1
2
SHEET
GATE ELEVATIONS
1
CONTRACTOR:
ABBREVIATIONS
SITE PLAN
GENERAL NOTES
APPLICABLE CODES
PROPERTY AREA 14,000 Sq.Ft.
AREA SUMMARY
SITE PLAN
-Cardinal Investment Properties
– Halladay, LP.
David Seidner (GEN PTR)
2925 Bristol St. Costa Mesa, CA
92626
Office: 714-557-1934
N/A
ZONE M1
A
COUNT
01
02
PROJECT
@ AT
ABV ABOVE
ALUM ALUMINUM
AFF ABOVE FIN FLOOR
BLDG BUILDING
BLK'G BLOCKING
BM. BEAM
B.N. BOUNDARY NAILING
CAB CABINET
CL CENTER LINE
CEIL CEILING
C.J. CEILING JOIST
CLR. CLEAR DIMENSION
CONC CONCRETE
CORR CORRIDOR
CONT CONTINUOUS
CONTR CONTRACTOR
CPT CARPET
DIM DIMENSION
DISP DISPENSER
DN DOWN
(E) EXISTING
E EAST
EA EACH
EA. WAY EACH WAY
ELEV ELEVATION
EXST'G EXISTING
F-E FIRE
EXTINGUISHER
FIXT FIXTURE
FLR. FLOOR
FLUO FLUORECENT
FOS FACE OF STUD
FOW FACE OF WALL
FTG FOOTING
FUT. FUTURE
GL GLASS OR GLAZING
GYP BD GYPSUM BOARD
HDR HEADER
HDWRE HARDWARE
HDCP HANDICAPPED
HR HOUR
i P.L. IMAGINARY
PROPERTY LINE
MFR MANUFACTURER
(N) NEW
N NORTH
NIC NOT IN CONTRACT
NTS NOT TO SCALE
oc ON CENTER
P.L. PROPERTY LINE
PLAS PLASTER
R.R. ROOF RAFTER
RPL'C REPLACE
RMVE'D REMOVED
REV REVISION
S SOUTH
SHLVS SHELVES
SHT'G SHEATHING
SIM SIMILAR
Sq.Ft. SQUARE FEET
TYP TYPICAL
UNO UNLESS NOTED
OTHERWISE
V.I.F. VERIFY IN FIELD
W WEST
W/ WITH
LEGEND
1'-0"
1'-0"
2'
-
0"
1 1/
4
"
2"
2"
3"
3"
8"
1 1/
4
"
3/
4"
1/
2
"
1/
2
"
3/
4
"
70 SQUARE INCHES
MINIMUM
60" A.F.F MIN. MEASURE TO THE
BOTTOM OF THE SIGN(S) (80" A.F.F. MIN.
IF LOCATED WITHIN A CIRCULATION
PATH). EQUAL FOR ALL STALL SIGNS
R7-8B(CA)
R99B(CA)
R99C
(CA)
R99
(CA)
2'
-
0
"
2'
-
0"
3"
2'
-
0"
2"
2"
1"
2"
2"
1 1/
2
"
NOTE: PROVIDE THE WORDS
"VAN ACCESSIBLE" BELOW THE
ISA WHERE OCCURS.
ALTERNATIVELY AN ADDITIONAL
VAN ACCESSIBLE SIGN MAY BE
ADDED BELOW
OR
ADA PARKING SIGNAGE
1) A REMOTE OPENING DEVICE IS REQUIRED. THE REMOTE GATE OPENING
DEVICE THAT WILL BE INSTALLED IS : 3M OPTICOM
2) IN THE EVENT OF LOSS OF NORMAL POWER TO THE GATE OPERATING
MECHANISM, IT SHALL BE
AUTOMATICALLY TRANSFERRED TO A FAIL-SAFE MODE ALLOWING THE GATE TO BE
PUSHED OPEN BY A
SINGLE FIREFIGHTER WITHOUT ANY OTHER ACTIONS, KNOWLEDGE, OR
MANIPULATION OF THE OPERATING
MECHANISM BEING NECESSARY.
a) A BATTERY MAY ONLY BE USED IN PLACE OF FAIL-SAFE MANUAL OPERATION
WHEN THE GATE
OPERATOR HAS A FAIL-OPEN MODE THAT WILL AUTOMATICALLY, IMMEDIATELY, AND
COMPLETELY
OPEN THE GATE AND KEEP IT OPEN UPON REACHING A LOW POWER THRESHOLD,
REGARDLESS OF THE
PRESENCE OF NORMAL POWER.
b) SHOULD THE GATE BE TOO LARGE OR HEAVY FOR A SINGLE FIREFIGHTER TO
OPEN MANUALLY, A
SECONDARY SOURCE OF RELIABLE POWER BY MEANS OF AN EMERGENCY
GENERATOR OR A CAPACITOR
WITH ENOUGH RESERVE TO AUTOMATICALLY, IMMEDIATELY, AND COMPLETELY
OPEN THE GATE UPON
LOSS OF PRIMARY POWER SHALL BE PROVIDED FOR FAIL-OPEN OPERATION.
3) IN ADDITION TO THE REMOTE OPERATOR, THE GATE CONTROL SHALL BE
OPERABLE BY A KNOX EMERGENCY
OVERRIDE KEY SWITCH EQUIPPED WITH A DUST COVER. UPON ACTIVATION OF THE
KEY SWITCH, THE GATE
SHALL OPEN AND REMAIN OPEN UNTIL RETURNED TO NORMAL OPERATION BY
MEANS OF THE KEY SWITCH.
WHERE A GATE CONSISTS OF TWO LEAVES, THE KEY SWITCH SHALL OPEN BOTH
SIMULTANEOUSLY IF
OPERATION OF A SINGLE LEAF ON THE INGRESS SIDE DOES NOT PROVIDE FOR THE
WIDTH, TURNING RADII,
OR SETBACKS NECESSARY FOR FIRE APPARATUS TO NAVIGATE THE VEHICLE
ENTRY POINT.
4) THE KEY SWITCH SHALL BE PLACED BETWEEN 42” AND 48” ABOVE THE
ROADWAY SURFACE AT THE
RIGHT SIDE OF THE ACCESS GATE WITHIN TWO FEET OF THE EDGE OF THE
ROADWAY. IN IRVINE, THE
SWITCH SHALL BE ON THE LEFT SIDE IN ACCORDANCE WITH IRVINE’S UNIFORM
SECURITY ORDINANCE.
5) THE KEY SWITCH SHALL BE READILY VISIBLE AND UNOBSTRUCTED FROM THE
FIRE LANE LEADING TO THE
GATE.
6) THE KEY SWITCH SHALL BE LABELED WITH A PERMANENT RED SIGN WITH NOT
LESS THAN ½” CONTRASTING
LETTERS READING “FIRE DEPT” OR WITH A “KNOX” DECAL.
OCFA NOTES FOR ELECTRIC VEHICLE GATES
TABULATION
PARKING
USE TYPE: Sec. 41-1391. Warehouses
and distribution and wholesale uses.
(a) The minimum off-street parking
requirements for warehouses and
distribution and wholesale uses are as
follows:
One (1) space for each one thousand
(1,000) square feet of gross floor area.
3 GATE SPECIFICATIONS 03
GROSS FLOOR AREAB 8,260 Sq.Ft.
UNIT #
G.F.A
PARKING
RATIO
REQUIRED
SPACES
EXISTING
SPACES
1:1000
SQ. FT
#2909
1600 Sq.Ft
2
NO PLANNED REDUCTION OF SPACES
USE
1:1000
SQ. FT
#2911
880 Sq.Ft
1
1:1000
SQ. FT
#2907
480 Sq.Ft
1
1:1000
SQ. FT
#2905
3050 Sq.Ft
4 11
#2903
2250 Sq.Ft
3
DRAFTING:
(714) 721 - 4067
Bryan Zamudio
Permit Sync Architecture
Santa Ana, CA 92704
2614 W Orion Ave
permitsync@gmail.com
c
VACANT
DISTRIB.
WAREH.
11
11
11
11
DISTRIB.
WAREH.
DISTRIB.
WAREH.
DISTRIB.
WAREH.
TOTALS 11 11
N/A
b
b
THERE IS A PARKING SURPLUS OF +0
PARKING SPACES NUMBERED
24"
Bldg #102122163
APPROVALS:
PLNG - C. Santana
BLDG - T. Le
POLICE - B. Martin
PUBLIC WORKS - Y. Soto
HOLD-2903 S
Halladay St4/14/2025
17'-0"
OPENING PORTION
DETAIL AT A
50x50x6 m s
hallow section
roller made out of 75x50
dia m s solid cylinder
10mm thk
ms plate
90x90x10 m s angle as rail
16mm axile bolt
150x50x6mm ms
plate hold fast
concrete
50x50x6 m s
hallow section
nylon roller
10mm plate to be
welded with
axile of roller
and screwed
with support wall
75
50
50
50
12
5
50
150
300 DETAIL AT B
support wall
A
B
3'-9"
7'
-
6
"
7'
-
6
"
MECHANICAL GATE
3'
-
0
"
m
i
n
17'- 0"
TYP. GENERIC ROUND
POST 3"
GENERIC ROUND
POST 3"
3'-9"
7'
-
6
"
GENERIC ROUND
POST 3"
PANIC / PUSH BAR
KICKPLATE
3'
-
1
0
"
3'
-
1
1
"
KNOX BOX
48
"
10
"
M
I
N
18"min.
STEEL COLUMN
HSS 3 1
2 " x 3 1
2 " x.188
F'c = 2500 psi
SMOOTH
SURFACE
JO
B
A
D
D
R
E
S
S
AS NOTED
a 12/16/20 BZ
b 2/26/25 BZ
DATE
SCALE
DRAWN
JOB
SHEET
REVISIONS BY
SHEET TITLE
PL
A
N
C
H
E
C
K
/
P
E
R
M
I
T
29
0
3
S
H
A
L
L
A
D
A
Y
S
T
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
5
0000
B.Z.
09.05.2024
(714) 721 - 4067
permitsync@gmail.com
PREPARED BY
BRYAN ZAMUDIO
09.01.2024
LE
G
A
L
D
E
S
C
R
I
P
T
I
O
N
AP
N
:
TR
A
C
T
:
LO
T
:
41
1
-
0
4
1
-
0
4
7
1
1
BL
K
:
B
8
/
B
ENGINEERING
REGISTEREDPROFESSIONALENGINEER
STATEOF CALIFORNIA
JOHN L.TIONGCOC70915
C I V IL
c 3/18/25 BZ
FRONT ELEVATION - DOOR ENTRANCE - EXTERIOR SCALE
1/2" = 1'-0"
FRONT ELEVATION - MECHANICAL GATE SCALE
1/2" = 1'-0"
2
ELEVATIONS
SECTION DETAIL A SECTION DETAIL B
FRONT ELEVATION - DOOR ENTRANCE - INTERIOR SCALE
1/2" = 1'-0"DOOR HARDWARE
PRODUCT:
ADAMS RITE 4568-11 EUROSTYLE DEADLATCH HANDLE
DOOR HARDWARE WILL COMPLY WITH ADA
STANDARDS FOR ACCESSIBLE DESIGN, INCLUDING
THE HEIGHT RANGE, OPERABILITY WITHOUT TIGHT
GRASPING OR TWISTING, WITHIN A 5-POUND FORCE.
b
c
HOLD-2903 S
Halladay St4/14/2025
JO
B
A
D
D
R
E
S
S
AS NOTED
a 12/16/20 BZ
b 2/26/25 BZ
DATE
SCALE
DRAWN
JOB
SHEET
REVISIONS BY
SHEET TITLE
PL
A
N
C
H
E
C
K
/
P
E
R
M
I
T
29
0
3
S
H
A
L
L
A
D
A
Y
S
T
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
5
0000
B.Z.
09.05.2024
(714) 721 - 4067
permitsync@gmail.com
PREPARED BY
BRYAN ZAMUDIO
09.01.2024
LE
G
A
L
D
E
S
C
R
I
P
T
I
O
N
AP
N
:
TR
A
C
T
:
LO
T
:
41
1
-
0
4
1
-
0
4
7
1
1
BL
K
:
B
8
/
B
ENGINEERING
REGISTEREDPROFESSIONALENGINEER
STATEOF CALIFORNIA
JOHN L.TIONGCOC70915
C I V IL
KNOXBOX 3200 - MODEL 3261 SCALE
1/2" = 1'-0"
CSL24U SLIDE GATE OPERATOR SCALE
1/2" = 1'-0"
3
GATE
PRODUCT
SPECS
DATA SHEET - SLIDE GATE OPERATOR SCALE
3/16" = 1'-0"
HOLD-2903 S
Halladay St4/14/2025
HOLD-2903 S
Halladay St4/14/2025
HOLD-2903 S
Halladay St4/14/2025
HOLD-2903 S
Halladay St4/14/2025
HOLD-2903 S
Halladay St4/14/2025
YES NO
INSTRUCTIONS:
ORAN GE COUNTY FI RE AUTHORI TY
Plan Submittal Criteria
COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects
and RESIDENTIAL TRACT developments
·Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place.
·Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section.
·If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA.
·In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations.
·Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding
requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602.
Address Suite City
Project Scope/Business Description
1.
2.
3.
4.
5.
6.
7.
8.
9.
Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways,
curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within
300 feet of an active or proposed oil well? Fire Master Plan (PR145)
Property is adjacent to a wildland area or non-irrigated native vegetation?
Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124)
Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from
an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170)
Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving
private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475)
Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.f t. (> 1,000
sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable
to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless
classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration
or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses
where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories
with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285)
Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card,
button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan
depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520)
Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment;
industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible
liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium
ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations?
Special Equipment Plan (PR315, PR340-PR382)
Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft
maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if
H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240)
Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard
commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330)
10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a
commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335)
Initial each of the following two items indicating that you have read and understand the statement:
11.*Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is
required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed
Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications.
12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located
in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327—
Initials the building department will determine specific requirements.
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name Signature
Phone Number ( )Date / /
Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA
review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the
applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the
appropriate plans and fees for OCFA review. 10-08-14 EE
COM
BZ
BZ
X
SERVICE REQUEST - SR#: 24002832
HOLD-2903 S
Halladay St4/14/2025
O R A N G E C O U N T Y F I R E A U T H O R I T Y
Plan Referral Form
Required for OCFA to review plans upon the request of the Building Department when
the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”.
City / County Official Requesting Review:
City / County Reference #: Date: __________________________________
City / County: _____________________________________ E-Mail: __________________________________
Contact Name: _____________________________________ Phone #: _________________________________
Title: _____________________________________
** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. **
Reason(s) for Review:
Please describe why OCFA Plan Review is or may be required by the City/County :
OCFA COMMENTS:
No further action required on this specific plan type, based
on information provided on: ____/______/______.
Project to be taken in for OCFA Review.
Other:
Name: _________________________________________
Contact #: ______________________________________ Date: _________________________________
OCFA Authorization
Updated: 06/02/2020 rs
HOLD-2903 S
Halladay St4/14/2025