Loading...
HomeMy WebLinkAbout902 S Gunther St - Planx x x x x x x x x x x x x x x x x x x x x x x x x x x Bldg# 101118957 APPROVALS: PLNG - PRaj BLDG - GHuang HOLD - 902 S Gunther St - 1011189575/28/2024 HOLD - 902 S Gunther St - 1011189575/28/2024 HOLD - 902 S Gunther St - 1011189575/28/2024 HOLD - 902 S Gunther St - 1011189575/28/2024 HOLD - 902 S Gunther St - 1011189575/28/2024        THESE CALCULATIONS ARE NOT VALID FOR SECURING A BUILDING PERMIT UNLESS STAMPED  AND SIGNED BY HANSEN‐HOKAMA, STRUCTURAL ENGINEERS.  HANSENHOKAMA STRUCTURAL ENGINEERS 180 E. Main St., Suite 201  Tustin, CA 92780  (714) 573‐0073  FAX (714) 573‐0688  Job No.               24‐10A Date              4/3/24  Page        1            STRUCTURAL CALCULATIONS   FOR REPAIR OF DAMAGE DUE TO VEHICLE IMPACT  AT:                                            THE CRUZ RESIDENCE  902 GUNTHER ST.  SANTA ANA, CALIFORNIA  HOLD - 902 S Gunther St - 1011189575/28/2024        THESE CALCULATIONS ARE NOT VALID FOR SECURING A BUILDING PERMIT UNLESS STAMPED  AND SIGNED BY HANSEN‐HOKAMA, STRUCTURAL ENGINEERS.  HANSENHOKAMA STRUCTURAL ENGINEERS 180 E. Main St., Suite 201  Tustin, CA 92780  (714) 573‐0073  FAX (714) 573‐0688  Job No.               24‐10A Date              4/3/24  Page        2     Building Codes – CHECK APPROPRIATE CODE    2022 California Building Code  2023 County of Los Angeles Building Code   2023 City of Los Angeles Building Code    STRUCTURAL MATERIAL SPECIFICATIONS  Typical unless noted otherwise in calculations    CONCRETE  –  f’c = 3,000 psi in 28 days minimum    REINFORCEMENT  –  ASTM A615, Grade 40 #4 bars and smaller, Grade 60 #5 bars and greater    MASONRY  –  Grade N Units:  f’m = 1,500 psi, n = 25.7    MISCELLANEOUS STEEL:          Structural    ASTM A36    Fy = 36 ksi            Pipes      ASTM A53    Fy = 35 ksi            Structural Tubes  ASTM A500    Fy = 46 ksi            Bolts      ASTM A307    Loads per code    LUMBER:  Stress Graded Douglas Fir‐Larch (All stresses in psi)          Joists/Rafters    No. 1      Fb = 1,000, Fv = 180          4 x Sawn Beams  No. 1      Fb = 1,000, Fv = 180            6 x Sawn Beams  No. 1      Fb = 1,350, Fv = 170            Glu‐Lam Beams  24F      Fb = 2,400, Fv = 240        STRUCTURAL HARDWARE: Connectors specified for framing and anchorage shall be equal to  Simpson Company “Strong‐Tie”. Model numbers listed are Simpson’s but equivalent hardware  may be substituted with the approval of the building official.    SOIL BEARING VALUE:    N/A  –  Damage did not affect existing foundation/footings.      HOLD - 902 S Gunther St - 1011189575/28/2024        THESE CALCULATIONS ARE NOT VALID FOR SECURING A BUILDING PERMIT UNLESS STAMPED  AND SIGNED BY HANSEN‐HOKAMA, STRUCTURAL ENGINEERS.  HANSENHOKAMA STRUCTURAL ENGINEERS 180 E. Main St., Suite 201  Tustin, CA 92780  (714) 573‐0073  FAX (714) 573‐0688  Job No.               24‐10A Date              4/3/24  Page        3    DESIGN LOADS    ROOF LOADS       ROOFING 3.0   SHEATHING 2.5   RAFTERS 2.0   MISC. 0.5   DL =   8.0  psf   LL =   20.0  psf   TL =   28.0  psf             GARAGE HEADER      SPAN = 16’‐0” MAX    w = 28 PSF x 20/2 = 280 PLF      M = 280 x 162/8 = 8960 FT‐LBS      SM 1000 X 1.25  = 86.01 IN3 < =  102.41 IN3                     (N) DF#1 4 X 14 HEADER                   HOLD - 902 S Gunther St - 1011189575/28/2024        THESE CALCULATIONS ARE NOT VALID FOR SECURING A BUILDING PERMIT UNLESS STAMPED  AND SIGNED BY HANSEN‐HOKAMA, STRUCTURAL ENGINEERS.  HANSENHOKAMA STRUCTURAL ENGINEERS 180 E. Main St., Suite 201  Tustin, CA 92780  (714) 573‐0073  FAX (714) 573‐0688  Job No.               24‐10A Date              4/3/24  Page        4    LATERAL ANALYSIS  THE SUBJECT BUILDING HAS BEEN DETERMINED TO HAVE SUSTAINED “LESS THAN  SUBSTANTIAL STRUCTURAL DAMAGE” THEREFORE IN ACCORDANCE WITH THE 2022  CALIFORNIA EXISTING BUILDING CODE, SECTION 405.2.1, THE DAMAGED ELEMENTS SHALL BE  PERMITTED TO BE RESTORED TO THEIR PREDAMAGE CONDITION. NEW STRUCTURAL MEMBERS  AND CONNECTIONS USED FOR THIS REPAIR SHALL COMPLY WITH THE 2022 CALIFORNIA  BUILDING CODE FOR NEW BUILDINGS OF A SIMILAR STRUCTURE, PURPOSE AND LOCATION.    HOLD - 902 S Gunther St - 1011189575/28/2024