HomeMy WebLinkAbout471 W Alton Ave Unit# E - PlanPROJECT INFORMATION PROPERTY OWNER NAME:FRANCOIS LINDSAY PHONE:- CONTRACTOR NAME:ILUM SOLAR PHONE:1-888-696-4586 DESIGN SPECIFICATIONS OCCUPANCY: R-3 CONSTRUCTION TYPE: SINGLE FAMILY RESIDENCE ZONING: RESIDENTIAL GROUND SNOW LOAD: 0 PSF WIND EXPOSURE: B WIND SPEED: 95 MPH APPLICABLE CODES & STANDARDS 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ENERGY CODE (ENERGY) 2022 CALIFORNIA GREEN BUILDING CODE (CALGREEN) 2020 NATIONAL ELECTRICAL CODE (NEC) 2022 CALIFORNIA FIRE CODE (CFC) SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS T-1 TYPE OF INTERCONNECTION: BACKFEED BREAKER IN THE MMC SCOPE OF WORK SYSTEM SIZE: STC: 18 X 400W = 7.200kW PTC: 18 X 376.7W = 6.781kW (18) CANADIAN SOLAR CS6R-400MS-HL (BLK) (400W) SOLAR MODULES (18) ENPHASE IQ8PLUS-72-2-US [240V] MICROINVERTERS (1) 125A ENPHASE IQ COMBINER 5/5C (X-IQ-AM1-240-5/5C) BOX (2) ENPHASE IQ BATTERY 5P (IQ BATTERY-5P-1P-NA) [240V] (2) 60A KNIFE AC DISCONNECT (SQUARE D DU222RB) MSP UPGRADE: NO MAIN BREAKER DERATE: NO RACKING & MOUNTING PV ATTACHMENT TYPE: UNIRAC FLASHLOC RM FOR EPDM FLAT ROOF RACKING TYPE: UNIRAC SM- ROOF MOUNT RACKING HARDWARE LINDSAY RESIDENCE NEW PHOTOVOLTAIC SYSTEM PROJECT - 7.200 kW COORDINATES: 33.705612, -117.873695 AERIAL VIEW SHEET # T-1 T-2 PV-1 PV-2 PV-3 E-1, E-2 E-3 S-1 S-2 S-3 S-4 S-5 S-6 SHEET NAME COVER SHEET PLAN NOTES SITE PLAN LAYOUT ATTACHMENT DETAILS MOUNTING DETAILS ELECTRICAL DIAGRAM WARNING LABELS SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET S-7 SPEC SHEET S-8 SPEC SHEET E-4 ELEVATION SHEET S-9 S-10 S-11 SPEC SHEET SPEC SHEET SPEC SHEET S-12 SPEC SHEET 6LJQHG 4USVDUVSBM 0OMZ - 6.58kWAC The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. BLDG # 101119111 ELECT # 20182675 APPROVALS MSmith 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 1.1.PROJECT NOTES: 1.2. THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC) ARTICLE 690, ALL MANUFACTURERS’S LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S (AHJ) APPLICABLE CODES. 1.3. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 1.4. GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE MICROINVERTER IN ACCORDANCE WITH NEC 690.5(A) 1.5. ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4 & NEC 690.60: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY 1.6. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. 1.7. ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.3]. 1.8. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. 1.9.SCOPE OF WORK: 1.10. PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. 1.11.WORK INCLUDES: 1.12. PV ROOF ATTACHMENTS - UNIRAC FLASHLOC RM FOR EPDM FLAT ROOF 1.13. PV RACKING SYSTEM INSTALLATION - UNIRAC SM ROOF MOUNT RACKING HARDWARE 1.14. PV MODULE AND INVERTER INSTALLATION - CANADIAN SOLAR CS6R-400MS-HL (BLK) (400W) SOLAR MODULES / ENPHASE IQ8PLUS-72-2-US [240V] MICROINVERTERS 1.15. PV EQUIPMENT GROUNDING 1.16. PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX 1.17. PV LOAD CENTERS (IF INCLUDED) 1.18. PV METERING/MONITORING (IF INCLUDED) 1.19. PV DISCONNECTS 1.20. PV GROUNDING ELECTRODE & BONDING TO (E) GEC 1.21. PV FINAL COMMISSIONING 1.22. (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV 1.23. SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE 1.24.SITE NOTES: 1.25. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 1.26. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH STORAGE BATTERIES. 1.27. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 1.28. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 1.29. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE.SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS T-2 1.56. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 1.57. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 1.58. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [2022 CEC 250.119] 1.59. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH CEC 690.47 AND CEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO CEC 250, CEC 690.47 AND AHJ. 1.60. GROUND-FAULT DETECTION SHALL COMPLY WITH CEC 690.41 IN GENERAL AND CEC 690.41 (A)(1) SPECIFICALLY. 1.61.DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 1.62. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 1.63. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 1.64. RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 1 FT OF PV ARRAY OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLED CONDUCTORS ≤30V AND ≤240VA [CEC 690.12(B)]. LOCATION OF LABEL ACCORDING TO AHJ 1.65. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO CEC 690.8, 690.9, AND 240. 1.66. EQUIPMENT THAT IS LISTED, LABELED, OR BOTH SHALL BE INSTALLED AND USED IN ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTING OR LABELING. CEC 110.3(B). 1.67. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO CEC 690.11 AND UL1699B. 1.68.ELECTRICAL INTERCONNECTION NOTES: 1.69. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120% OF THE BUSBAR RATING. 1.70. WHEN THE SUM OF THE PV SOURCES EQUALS >100% OF THE BUSBAR RATING, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD. 1.71. AT MULTIPLE PV OUTPUT COMBINER PANEL, THE TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED. 1.72. SUPPLY-SIDE TAP INTERCONNECTION SHOULD BE WITH SERVICE ENTRANCE CONDUCTORS. 1.73. BACKFEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING. 1.30.EQUIPMENT LOCATIONS: 1.31. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY 2022 CEC 110.26. 1.32. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY 2022 CEC 690.31 (A),(C) AND CEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C) 1.33. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO 2022 CEC 690.34. 1.34. ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT . 1.35. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO 2022 CEC APPLICABLE CODES. 1.36. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 1.37.STRUCTURAL NOTES: 1.38. RACKING SYSTEM 1.39. PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND 1.40. A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. 1.41. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED SEALED PER LOCAL REQUIREMENTS. 1.42. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 1.43. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 1.44. WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. 1.45.WIRING & CONDUIT NOTES: 1.46. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 1.47. CONDUCTORS SIZED ACCORDING TO 2022 CEC 690.8, 2022 CEC 690.7. 1.48. VOLTAGE DROP LIMITED TO 2%. 1.49. DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE WIRING CLIPS. 1.50. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNCECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [2022 CEC 110.15 1.51.GROUNDING NOTES: 1.52. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 1.53. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO 2022 CEC 690.43 AND MINIMUM 2022 CEC TABLE 250.122. 1.54. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORDING WITH 2022 CEC 250.134 AND 2022 250.136(A). 1.55. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO CEC 690.45 AND MICROINVERTER MANUFACTURER'S INSTRUCTIONS. 6LJQHG 4USVDUVSBM 0OMZ 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 N SCALE: 1/16" = 1'-0" PV SYSTEM SITE PLAN PV SYSTEM SIZE: 7.2 kW DC CONSTRUCTION NOTES SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/26/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS PV-1 1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. 2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITHSTAND A BASIC WIND SPEED OF 95 MPH (3 SECOND GUST), WIND EXPOSURE B. 3. THE ROOF MEMBERS ARE 2"X 6" RAFTER AT 24" ON CENTER. CONNECTION TO STRUCTURE SHALL NOT BE WITHIN 11" OF NAILING PLATES. 4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF SHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 6. ROOF ACCESS POINTS SHALL BE PROVIDED PER THE FOLLOWING (CRC R324.7.1, CBC 3111.2.1) 6.1. LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. 6.2. LOCATED AT STRONG POINTS OF CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS: TREES, WIRES, OR SIGNS. (18) CANADIAN SOLAR CS6R-400MS-HL (BLK) (400W) SOLAR MODULES WITH AN ENPHASE IQ8PLUS-72-2-US [240V] MICRO-INVERTERS MOUNTED TO THE BACK OF EACH MODULE MOUNTED ON EPDM FLAT ROOF LEGEND M METER MAIN COMBO CB COMBINER BOX BATT BATTERY DRIVEWAY NEW SOLAR PANELS ENERGY STORAGE SYSTEMS (ESS) SHALL NOT BE LOCATED LESS THAN 3 FEET FROM DOORS AND WINDOWS DIRECTLY ENTERING THE DWELLING UNIT PER 2022 CALIFORNIA RESIDENTIAL CODE R328.4 LOCATION OF "RAPID SHUTDOWN" AC DISCONNECT NEC 690.12 ACD AC DISCONNECT Roof Section 1 Roof Azimuth: 180° Roof Tilt: 2° M CB PV INTERCONNECTION POINT. LOCATION OF METER MAIN COMBO, (2) AC DISCONNECT, COMBINER BOX & (2) ENPHASE IQ BATTERY 5P MOUNTED ON EXTERIOR WALL OF A GARAGE. ROOF OBSTRUCTIONS BATT 471 W ALTON AVE E ACD PR O P E R T Y L I N E WA L K W A Y WA L K W A Y WA L K W A Y PR O P E R T Y L I N E PR O P E R T Y L I N E TRIUMPH WY CAL-FIRE ROOF LADDER ACCESS POINT BATT ACD CAL-FIRE ROOF LADDER ACCESS POINT LOCATION OF "RAPID SHUTDOWN" AC DISCONNECT NEC 690.12 PR O P E R T Y L I N E CAL-FIRE ROOF LADDER ACCESS POINTGARAGE EGARAGE DGARAGE CGARAGE BGARAGE A CONDO E CONDO DCONDO C CONDO B CONDO A 6LJQHG 4USVDUVSBM 0OMZ 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 6'6'6' N SCALE: 3/32" = 1'-0" PV SYSTEM MOUNTING DETAILS UNIRAC FLASHLOC RM FOR EPDM FLAT @ 72" O.C MAX PROPOSED UNIRAC SM RACKING PROPOSED CANADIAN SOLAR CS6R-400MS-HL (BLK) (400W) PV SOLAR MODULES EXISTING 2"X 6" ROOF RAFTER @ 24"O.C. SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS PV-2 Roof Section 1 Roof Azimuth: 180° Roof Tilt: 2° EXISTING EPDM FLAT ROOF 6LJQHG 4USVDUVSBM 0OMZ 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 910 10 6 21 7 9 21 7 26 S-5 D5 20 15 18 22121413 S-5 D4 27 1 2 54 8 3 25 24 23 D4 DETAIL (TRANSVERSE) NOT TO SCALE D5 DETAIL (LONGITUDINAL) NOT TO SCALE D1 RACKING DETAIL (TRANSVERSE) NOT TO SCALE D3 RACKING DETAIL (TOP) NOT TO SCALE D2 RACKING DETAIL (LONGITUDINAL) NOT TO SCALE SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS PV-3 EPDM FLAT 1. ROOF MATERIAL:EPDM FLAT 2. ROOF STRUCTURE: RAFTER 3. ATTACHMENT TYPE: UNIRAC FLASHLOC RM 4. MODULE MANUFACTURER: CANADIAN SOLAR 5. MODULE MODEL: CS6R-400MS-HL (BLK) (400W) 6. MODULE LENGTH: 67.8'' 7. MODULE WIDTH: 44.6" 8. MODULE WEIGHT: 49.4 LBS. 9. SEE SHEET S-1 FOR DIMENSION(S) 10. MIN. FIRE OFFSET: 11. RAFTER SPACING: 24" O.C. 12. RAFTER SIZE: 2"X 6" NOMINAL 13. LAG BOLT DIAMETER: 5/16 IN. 14. LAG BOLT EMBEDMENT: 2.5 15. TOTAL # OF ATTACHMENTS: 30 16. TOTAL AREA: 377.99 SQ. FT. 17. TOTAL WEIGHT: 889.20 LBS. 18. WEIGHT PER ATTACHMENT: 29.64 LBS. 19. DISTRIBUTED LOAD: 2.35 PSF 20. MAX. HORIZONTAL STANDOFF: 72 IN. 21. MAX. VERTICAL STANDOFF: LANDSCAPE: 26 IN., PORTRAIT: 39 IN. 22. STANDOFF STAGGERING: NO 23. RAIL MANUFACTURER AND MODEL (OR EQUIV.):UNIRAC SM 24. RAIL WEIGHT: 0.436 PLF. 25. MAX. RAFTER SPAN: 12 FT. 26. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX. 6LJQHG 4USVDUVSBM 0OMZ 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 3 BACKFEED BREAKER M POINT OF DELIVERY AND INTERCONNECTION 100A EXISTING 240V/125A METER MAIN COMBO SINGLE PHASE 50A (E) GROUNDING ELECTRODE OR (UFER) N 3 CT CABLE (N) VISIBLE LOCKABLE 2 POLE 60A 'KNIFE' AC DISCONNECT (SQUARE D DU222RB) 9 PV CIRCUIT 1: 9 MODULES/PARALLEL GR O U N D L E V E L - HO U S E E X T E R I O R 9 PV CIRCUIT 2: 9 MODULES/PARALLEL 12 12 1 1 (N) JUNCTION BOX WITH IRREVERSIBLE GROUND SPLICE 20A 20A N 15A (N) 18 CANADIAN SOLAR CS6R-400MS-HL (BLK) (400W) SOLAR MODULES WITH AN ENPHASE IQ8PLUS-72-2-US [240V] MICRO-INVERTER ATTACHED TO THE BACK OF EVERY MODULE. NOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THE GROUNDING / BONDING, GROUND CLAMPS ARE AT EACH END OF THE EMT CONDUIT WITH THE WIRE THEN FREE AIR'D TO THE GROUND CLAMP ON THE RACKING RAIL 40A (N) 125A/240V AC COMBINER BOX 5/5C (X-IQ-AM1-240-5/5C) WITH ENPHASE IQ ENVOY COMM. GATEWAY IQ GATEWAY [CRD-PCS NON-EXPORT] 1. ENVOY MUST BE NO FARTHER THAN 150' FROM THE LAST MICROINVERTER. 2. MAX DISTANCE BETWEEN ENSEMBLE DEVICES IS 50' LINE OF SIGHT WITH NO OBSTRUCTIONS. EN P H A S E I Q E N V O Y CO M M U N I C A T I O N S GA T E W A Y CELL MODEM GATEWAY WIRELESS COMM 2 (N) ENPHASE IQ BATTERY-5P-1P-NA [240V] 4 (N) VISIBLE LOCKABLE 2 POLE 60A 'KNIFE' AC DISCONNECT (SQUARE D DU222RB) 4 (N) ENPHASE IQ BATTERY-5P-1P-NA [240V] 5 SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS E-1 MAIN SERVICE PANEL 240/120V 1Ø, 3W MAIN BUSS: 125A MAX BREAKER SIZE: (125A X 1.2) - 100A = 50.0A NOTE : CT CABLES SHOULD NOT RUN THROUGH BATTERIES HOT WIRE. ESS DETAILS MODEL NAME ENPHASE IQ BATTERY-5P-1P-NA [240V] PEAK OUTPUT POWER 6.14 kVA TOTAL CAPACITY 5.0 kWh ENERGY STORAGE SYSTEMS (ESS) SHALL NOT BE LOCATED LESS THAN 3 FEET FROM DOORS AND WINDOWS DIRECTLY ENTERING THE DWELLING UNIT PER 2022 CALIFORNIA RESIDENTIAL CODE R328.4 ALL EQUIPMENT LISTED IS SUBJECT TO AVAILABILITY AND MAY BE REPLACED WITH AN EQUIVALENT PRODUCT. METER # 222013006497 BATTERY IMPORT ONLY MODE: THIS FEATURE ENSURES THE ENPHASE IQ BATTERY NEVER EXPORTS ANY POWER TO THE GRID. ENPHASE BATTERIES ALWAYS OPERATE IN IMPORT ONLY MODE. 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS E-2 Inverter Ratings Inverter Make/Model ENPHASE IQ8PLUS-72-2-US [240V] Max DC Volt Rating 60V Max con output Power 290W Max Nominal Voltage 240V Max AC Current 1.21A Max OCPD Rating 20A DESIGN TEMPERATURES ASHRAE EXTREME LOW 2°C ASHRAE 2% HIGH 31°C PV Module Ratings @ STC Module Make/Model CANADIAN SOLAR CS6R-400MS-HL (BLK) (400W) Max Power-Point Current (Imp)12.99A Max Power-Point Voltage (Vmp)30.8V Open-Circuit Voltage (Voc)36.8V Short-Circuit Current (Isc)13.85A Max Series Fuse (OCPD)25A Nominal Maximum Power at STC (Pmax)400W Maximum System Voltage 1000V Voc Temperature Coefficient -0.26%/°C SYSTEM SUMMARY BRANCH #1 BRANCH #2 INVERTERS PER BRANCH 9 9 MAX AC CURRENT 10.89A 10.89A MAX AC OUTPUT POWER 2610W 2610W ARRAY STC POWER 7200W MAX AC CURRENT 21.78A MAX AC POWER 5220W Conduit and Conductor Schedule Tag Description Wire Gauge # of Conductors Conduit Type Conduit Size 1 Enphase Q cable - THWN-2 12 AWG 2 N/A - Free Air N/A - Free Air 1 Bare Copper Ground (EGC/GEC)6 AWG 1 N/A - Free Air N/A - Free Air 2 THWN-2 12 AWG 4 3 THWN-2 8 AWG 3 EMT 3/4" 3 THWN-2 - Ground 10 AWG 1 EMT 3/4" 4 4 EMT 3/4" 2 THWN-2 - Ground 10 AWG 1 EMT 3/4" THWN-2 THWN-2 - Ground 2 1 8 AWG 10 AWG 3/4" 3/4" EMT EMT 5 5 THWN-2 THWN-2 - Ground 2 1 10 AWG 10 AWG 3/4" 3/4" EMT EMT 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 N POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN CAUTION: (N) SOLAR PANELS AND MICRO-INVERTERS ON ROOF SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS E-3 TRIUMPH WY PV INTERCONNECTION POINT. LOCATION OF METER MAIN COMBO, COMBINER BOX, (2) AC DISCONNECT & (2) ENPHASE IQ BATTERY 5P 1. NOT ALL PLACARDS SHOWN MAY BE REQUIRED BY LOCAL AHJ. CONTRACTOR TO VERIFY PLACARD REQUIREMENTS WITH LOCAL AHJ BEFORE INSTALLATION. 2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF THE CALIFORNIA ELECTRICAL CODE 3. ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTCHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHOD. 4. DIRECTORY PLACARD MARKING CONTENT AND FORMAT: RED BACKGROUND, WHITE LETTERING, MINIMUM 3/8" LETTER HIEGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. PERMANENT SIGNAGE NOTES: WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2022: 705.12(B)(3)(2) ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2022: 705.12(B)(3)(3) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: ON OR NO MORE THAT 3 M (10 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. ELECTRICAL SHOCK HAZARD WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 705.15(C)(4)& 690.13(B) LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2022:690.56(C)(2), CFC 2022: 1204.5.3 21.78 PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2022: 690.54 CAUTION TRI POWER SOURCES SECOND SOURCE IS PV SYSTEM THIRD SOURCE IS AC BATTERY ! LABEL LOCATION : BATTERY F.D. – ELECTRICAL BLDG DISCONNECT # 2 of 2 # 2 F.D. – ELECTRICAL BLDG DISCONNECT # 1 of 2 # 1 471 W ALTON AVE E 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 2'-4" ME T E R M A I N C O M B O ON NORTH WALL OF GARGE ENPHASEe ENPHASE IQ COMBINER 5/5C AC DISCONNECT 1 2'-4"2'-4" 3'-3" 1'-11" 2'-4" ENPHASEe ENPHASE IQ BATTERY-5P-1P-NA [240V] 6" 2 AC DISCONNECT 2'-4" ON SOUTH WALL OF GARGE 3'-3" 1'-11" 2'-4" ENPHASEe ENPHASE IQ BATTERY-5P-1P-NA [240V] SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS E-4 EQUIPMENT ELEVATION VIEW ELECTRICAL POWER SOURCE DISCONNECT SCHEDULE DISCONNECT NUMBER DISCONNECTION OPERATION/EQUIPMENT/DEVICE 1 OF 2 2 OF 2 60A BLADE DISCONNECT 60A BLADE DISCONNECT ENERGY SOURCE NEW SOLAR PV ESS 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS S-1 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS S-10 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS S-11 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS S-12 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS S-2 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS S-3 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS S-4 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS S-5 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS S-6 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS S-7 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS S-8 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 SHEET CONTRACTOR ILUM SOLAR 471 W ALTON AVE E, SANTA ANA, CA 92707 APN:93318079 DATE:4/19/2024 LINDSAY RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OAS S-9 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 IL□m ENERGY SOLUTIONS November 16, 2023 To Whom It May Concern: This letter is to confirm that Posese Pulu, Cheryl Vega, Colton Kelsey, Sharonda Holt, Matt Morales, and R eyna Carrillo are authorized agents for ILUM SOLAR and have the permission to pull permits and city business licenses for our company. Should you have any questions, please do not hesitate to contact us at 888-696-4586 Sincerely, 8e11jAw.i11 Her11rtedf CSLB: 1092865 / 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 CALIFORNIA ACKNOWLEDGMEN-T CIVIL CODE § 1189 A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. State of California County of SAL-C c:L fl-4' A. -f 0 } onWov, ll� 2-ol3 before me, lc:,ffl� EJl,ro if,IJ0/v9 Pv!olt"e-Datel /-)o_(_V\_ S _H-1-�-e-J�s-,�rt�N�a-m-e-an...,d�T.�it-le_o,_f_t_li -1e-O-ffi�i�ce�r���-personally appeared �13�_,e:_n-r-+j_g.........._m�1'_,_n _____ r(�c:.. _____ �T ______________ _ 0 Name(s) of Signer(s) who proved to me on the basis of satisfactory evidence to be the person(81 whose nam� •is/a.re subscribed to the within instrument and acknowledged to me that he/she'ft� executed the same in his/her/th.eir authorized capacity(ies)<'and that by his/hef1thfai1' signature(:;)'on the instrument the person�),.>or the entity upon behalf of which the perso�acted, executed the instrument. Place Notary Seal andlbr Stamp Above I certify under PENAL TY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. Signature ---�---= ___ L_--........___.._· ______ _ Signature of Notary Public OPTIONAL Completing this information can deter alteration of the document or fraudulent reattachment of this form to an unintended document. Description of Attached Document Title or Type of Document: ___________________________ _ Document Date: _____________________ Number of Pages: ____ _ Signer(s) Other Than Named Above: ________________________ _ Capacity(ies) Claimed by Signer(s) Signer's Name: ____________ _ □Corporate Officer -Title(s): ______ _□Partner -□ Limited □ General□Individual □Attorney in Fact□Trustee □Guardian or Conservator□Other:Signer is Representing: _________ _ ©2018 National Notary Association Signer's Name: □Corporate Officer -Title(s): ______ _□Partner -□ Limited □ General□Individual □Attorney in Fact□Trustee □Guardian or Conservator□Other:Signer is Representing: _________ _ 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 04/19/2024 Design Criteria Code 2022 California Building Code (ASCE 7-16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 95 mph PV Dead Load DPV 3 psf Exposure B Roof Live Load Lr 20 psf RE: Structural Certification for Installation of Residential Solar FRANCOIS LINDSAY:471 W ALTON AVE E, SANTA ANA, CA 92707 Attn: To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report, the roof is made of EPDM Falt roofing over roof plywood supported by 2X6 Rafters at 24 inches. The slope of the roof was approximated to be 2 degrees. After review of the field observation data and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. projects@evengineersnet.com http://www.evengineersnet.com 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 Structural Letter for PV Installation Date:04/19/2024 Job Address:471 W ALTON AVE E SANTA ANA, CA 92707 Job Name:FRANCOIS LINDSAY Job Number:240419FL Scope of Work Table of Content Sheet 2 Cover 3 Attachment Uplift checks 4 Roof Framing Check 5 Seismic Check and Scope of work Engineering Calculations Summary Code 2022 California Building Code (ASCE 7-16) Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf References system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's projects@evengineersnet.com http://www.evengineersnet.com 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 Wind Load Cont. 95 mph ASCE 7-16 Figure 26.5-1B B 1.0 ASCE 7-16 Sec 26.8.2 0.65 ASCE 7-16 Table 26.10-1 0.85 ASCE 7-16 Table 26.6-1 12.74 psf 2.0 Degrees 1.5 Conservatively assuming all exposed 0.8 Uplift (W)Zone(1')Zone(1)Zone(2)Zone(3) Fig. 30-3-2 GCp=-0.9 -1.4 -1.9 -2.4 Eq. 29.4-7 P=qh pγ Eγ a -13.75 -21.40 -29.04 -36.68 GC =0.3 Figure 30.3-2 γ E)(γa)=2.52 Equation 29.4-7 Rafter Attachments: 0.6D+0.6W (CD=1.6) Connection Check Attachment max. spacing=6 ft 5/16" Lag Screw Withdrawal Value=266 lbs/in Table 12.2A - NDS 2.5 in DFL Assumed Prying Coefficient 1.4 Allowable Capacity=760 lbs Zone Trib Width Area (ft)Uplift (lbs)Down (lbs) Zone(1')6 16.5 91.2 91.1 Zone(1)6 16.5 132.8 91.1 Zone(2)6 16.5 174.4 91.1 Zone(3)6 16.5 216.0 91.1 216.0 <760 2.Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. II γE γa= Zt q = 0.00256K K K K V = Pitch = Risk Category = KZ = K = e projects@evengineersnet.com http://www.evengineersnet.com 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 Vertical Load Resisting System Design Roof Framing Rafters Fully Exposed pg=0 psf 1.1 0.9 1.0 pf = 0 psf pfmin. = 0.0 psf ps = 0 psf Conservatively (Cs=1)0 plf Max Length, L =10.0 ft (Rafter maximum Allowable Horizontal Span) Tributary Width, WT =24 in Dr =10 psf 20 plf Load Case: DL+0.75(0.6W+S) cos(θ)+PDL=40 plf OK Load Case: DL+S cos(θ)+PDL=38 plf OK Load Case: DL+0.6W cos(θ)+PDL=41.0 plf OK Member Capacity 2X6 φ λ Cross-Sectonal Area, A =8.25 Satisfactory Satisfactory projects@evengineersnet.com http://www.evengineersnet.com 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 Siesmic Loads Check Roof Dead Load 10 psf % or Roof with Pv 35.6% Dpv and Racking 3 psf Average Total Dead Load 11.1 psf Increase in Dead Load 4.3%OK Limits of Scope of Work and Liability The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. We have based our structural capacity determination on information in pictures and a drawing set titled PV plans - FRANCOIS LINDSAY. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this Structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. projects@evengineersnet.com http://www.evengineersnet.com 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 471 W ALTON AVE # E, SANTA ANA, CA 92707 Ilum Solar 1092865 Reyna G. Carrillo 562.525.2868 04/30/2024 rcarrillo@ilumsolar.com 471 W Alton Ave Unit# E- 101119111& 201826755/13/2024