Loading...
HomeMy WebLinkAbout2413 S Fairview St Unit #A - PlanTO OBTAIN THE PERMITS TO REPLACE THE EXISTING WALK-IN COOLER SECTION OF 14 COOLERS WITH 28" DOORS (REPLACE LIKE FOR LIKE). TO PROPOSE 11 NEW WALK-IN COOLERS WITH 30" DOORS. REMOVE THE WALL BETWEEN THE EXISTING AND PROPOSED COOLERS CREATING ONE BIG WALK-IN COOLER AREA. TO REPLACE THE EX. 2 DOOR FREEZER WITH NEW PROP. 2 DOOR FREEZER (REPLACE LIKE FOR LIKE). SA N T A A N A B H L , I N C . BE V E R A G E H O U S E L I Q U O R # 2 5 C24-L20 JUNE 2024 PR O J E C T A D D R E S S : 27 1 3 S . F A I R V I E W S T . , SA N T A A N A , C A . 9 2 7 0 4 CO N T A C T I N F O : UP L A N D B H L I N C . MA R K M A I D A 1 B&S 08-12-2024 THOMAS R .STEENO STATE OF CAL IFORNIA C-26448 LICENSED ARCHITECT REN.2 /28/25 THESE DOCUMENTS AND THE DESIGN AND IDEAS INCORPORATEDHEREIN, AS AN INSTRUMENTOF A PROFESSIONAL SERVICE,ARE THE SOLE PROPERTY OF STEENO DESIGN STUDIO INC. ANY USE, IN WHOLE OR IN PART FOR WHICH THEY WERE NOT PROVIDED SHALL BE UNLAWFUL P H O N E ( 7 6 0 ) 2 4 4 - 5 0 0 1 F A X ( 7 6 0 ) 2 4 4 - 1 9 4 8 1 1 7 7 4 H E S P E R I A R O A D , S U I T E B H E S P E R I A , C A . 9 2 3 4 5 THESEPLANS SHALL COMPLY WITH THE 2022 CALIFORNIA BUILDING CODE WHICH ADOPTS THE 2022 CMC, 2022 CPC,2022 CEC, 2022 CGC, 2022 CRC AND THE 2022 ENERGY STANDARDS R E V I S I O N S DATE FINISHED w w w . s t e e n o d e s i g n . c o m PR O J E C T : JOB NO. SHEET NAME: PAGE IN C . D E S I G N S T U D I O A R C H I T E C T U R E D E S I G N P L A N N I N G S T E E N O NO R T H SITE PLAN A-0 S FAIRVIEW ST. WA R N E R A V E . EX. BUILDING NOT A PART EX. BUILDING NOT A PART EX. BUILDING NOT A PART BEVERAGE HOUSE LIQUOR # 25 AREA OF PROP. WORK @ HATCH AREA STEENO DESIGN STUDIO, INC. ARCHITECT: TOM STEENO 11774 HESPERIA RD. SUITE B-1 PH: 760.244.5001 FX: 760.244.1948 MARK MAIDA UPLAND BHL INC. 13302 RANCHERO RD. 92344 PH: (760) 964-7936 APPLICANT / OWNER: PROJECT DATA 1 V - B STORIES: OCCUPANCY'S: CONSTRUCTION TYPE: ZONE:C-4 B NOEXISTING FIRE SPRINKLERS: A.P.N.: BUILDING CODE: ................................................ ** THESE PLANS SHALL COMPLY W/ SANTA ANA MUNICIPAL CODE AND 2022 EDITION OF THE CALIFORNIA BUILDING CODE WHICH ADOPTS THE 2018 IBC, 2022 CMC, 2022 CPC AND THE 2022 CEC AND CALIFORNIA AMENDMENTS. ELECTRICAL CODE: ........................................... 2022 CALIF. BUILDING CODE (C.B.C.) 2022 CALIF. ELECTRICAL CODE (C.E.C.) MECHANICAL CODE: ......................................... 2022 CALIF. MECHANICAL CODE (C.M.C.) PLUMBING CODE: .............................................. 2022 CALIF. PLUMBING CODE (C.P.C.) ENERGY CODE (TITLE 24. PT. 6): ..................... 2022 CALIF. ENERGY STANDARDS GREEN CODE (TITLE 24. PART 11): ................. 2022 CALIF. GREEN BUILDING STANDARDS (C.G.C.) FIRE CODE: ........................................................ 2022 CAL. FIRE CODE (C.F.C.) APPLICABLE CODES 0 15 30 60 120 SCALE = 1:30 SCOPE OF WORK VICINITY MAP NORTH PROJECT LOCATION NOTES: THIS FACILITY TO MAINTAIN THE SAME STORE SIZE AND HOURS OF OPERATION W SEGERSTROM AVE. W WARNER AVE. W MACARTHUR BLVD.S F A I R V I E W S T . S R A I T T S T . S B R I S T O L S T . S B E A R S T . S H A R B O R BL V D . ARCHITECT / REPRESENTATIVE: 9505-051-16 SITE PLAN SCALE: 1:30 SHEET INDEX 01 - A-1 05 - E-0 05 - E-1 05 - E-2 01 - A-0 TITLE SHEET - SITE PLAN FLOOR PLAN ELECTRICAL SPECS. FLOOR PLAN ELECTRICAL FLOOR PLAN 1 1 S: \ 2 0 2 4 A p r o j e c t s \ 0 2 - C o m m e r c i a l \ L - P \ 2 0 - M a i d a S a n t a A n a \ A - 0 S i t e P l a n _ S a n t a A n a . d w g , 9 / 3 / 2 0 2 4 1 1 : 0 9 : 3 0 A M , D W G T o P D F . p c 3 Bldg#103120201 APPROVALS: PLNG - PRaj BLDG - CSG Consultants 2413 S Fairview St Unit #A9/20/2024 SA N T A A N A B H L , I N C . BE V E R A G E H O U S E L I Q U O R # 2 5 C24-L20 JUNE 2024 PR O J E C T A D D R E S S : 27 1 3 S . F A I R V I E W S T . , SA N T A A N A , C A . 9 2 7 0 4 CO N T A C T I N F O : UP L A N D B H L I N C . MA R K M A I D A 1 B&S 08-12-2024 FLOOR PLAN A-1 THOMAS R .STEENO STATE OF CAL IFORNIA C-26448 L ICENSED ARCHITECT REN. 2 /28/25 THESE DOCUMENTS AND THE DESIGN AND IDEAS INCORPORATED HEREIN, AS AN INSTRUMENT OF A PROFESSIONAL SERVICE, ARE THE SOLE PROPERTY OF STEENO DESIGN STUDIO INC. ANY USE, IN WHOLE OR IN PART FOR WHICH THEY WERE NOT PROVIDED SHALL BE UNLAWFUL P H O N E ( 7 6 0 ) 2 4 4 - 5 0 0 1 F A X ( 7 6 0 ) 2 4 4 - 1 9 4 8 1 1 7 7 4 H E S P E R I A R O A D , S U I T E B H E S P E R I A , C A . 9 2 3 4 5 THESE PLANS SHALL COMPLY WITH THE 2022 CALIFORNIA BUILDING CODE WHICH ADOPTS THE 2022 CMC, 2022 CPC, 2022 CEC, 2022 CGC, 2022 CRC AND THE 2022 ENERGY STANDARDS R E V I S I O N S DATE FINISHED w w w . s t e e n o d e s i g n . c o m PR O J E C T : JOB NO. SHEET NAME: PAGE IN C . D E S I G N S T U D I O A R C H I T E C T U R E D E S I G N P L A N N I N G S T E E N O NO R T H 55'-0" 55 ' - 0 " 46 ' - 3 " 4' - 2 " 4' - 7 " 55'-0" 6'-9"14'-0"34'-3" 6'-8"27'-7" 55 ' - 0 " 7' - 1 " 47 ' - 1 1 " 6'-3" x 6'-7" EX. CLG. RESTROOM 41'-0" x 7'-9" EX. CLG. UTILITY RM./ STORAGE 5'-8" x 3'-8" EX. CLG. OFFICE 37'-3" x 31'-9" EX. CLG. C-STORE 8'-4" x 27'-0" EX. CLG. CASHIER 33'-5" x 13'-3" EX. WALK-IN COOLER EXISTING (14) 28" COOLER DOORS EXISTING (1) 36" DELIVERY DOORS PROPOSED WALK-IN COOLER (11) 30" COOLER DOORS 2-DOOR FREEZER EX. 3'-0" x 24'-0" GONDOLA FLOOR PLAN SCALE: 1/4" = 1'-0" EXISTING COOLER TO BE REPLACE BY NEW PROP. COOLER OF SAME SIZE AND SAME NUMBER OF DOORS PROP. 7'-0" x 32'-0" COOLER W/ (11) 30" x 79" COOLER DOORS 2 DOOR FREEZER TO REPLACE OLD FREEZER LINE OF OLD COOLER WALL TO BE REMOVED TO CONNECT EX. RENOVATED COOLER AND NEW PROPOSED COOLER COOLER SPECS. EX. REACH-IN FREEZER EX. REACH-IN FREEZER EX. REACH-IN FREEZER EX. SANDWICH DISPLAY EX. 3'-0" x 24'-0" GONDOLA EX. 3'-0" x 24'-0" GONDOLA EX . L I Q U O R D I S P L A Y ELEC. PANEL 'A' ELEC. PANEL 'B' LARR # 252191 1 6' - 7 " 4' - 0 " 4' - 0 " 5' - 5 " 3'-10" 30" x 48" ACCESSIBILTY CLEAR SPACE1 1 3' - 0 " FLUSH FLOOR @ ENTRY S: \ 2 0 2 4 A p r o j e c t s \ 0 2 - C o m m e r c i a l \ L - P \ 2 0 - M a i d a S a n t a A n a \ A - 1 F l o o r P l a n _ S a n t a A n a . d w g , 8 / 2 1 / 2 0 2 4 9 : 0 5 : 5 0 A M , D W G T o P D F . p c 3 2413 S Fairview St Unit #A9/20/2024 SA N T A A N A B H L , I N C . BE V E R A G E H O U S E L I Q U O R # 2 5 C24-L20 JUNE 2024 PR O J E C T A D D R E S S : 27 1 3 S . F A I R V I E W S T . , SA N T A A N A , C A . 9 2 7 0 4 CO N T A C T I N F O : UP L A N D B H L I N C . MA R K M A I D A 1 B&S 08-12-2024 FLOOR BOX (DUPLEX RECEPTACLE ONLY) COMBINATION PHONE & DATA RING WITH 3/4" CONDUIT TO CEILING ELECTRICAL SYMBOL LIST RECESSED 2x4 FIXTURE 2 LAMP RECESSED 2x4 FIXTURE 3 LAMP RECESSED 2x4 FIXTURE 3 LAMP TANDEM WIRED RECESSED 2x4 FIXTURE 4 LAMP SURFACE 1x4 WRAP RECESSED DOWN LIGHT INCANDESCENT RECESSED DOWN LIGHT FLUORSCENT SHOE BOX STYLE FIXTURE (WATTAGE AS NOTED) WALL PACK (WATTAGE AS NOTED) EXIT SIGN (ARROWS AS NOTED) NIGHT LIGHT (ON 24 HOURS) INS DISCONNECT SWITCH, RATING AS NOTED ,,P M K S S S S S 3 4S , S CONDUIT DOWN CONDUIT UP T EXHAUST FAN (CONNECT ONLY) SINGLE POLE SWITCH 48" TO TOP (RESTROOMS +44" TO TOP) SWITCH WITH P=PILOT LIGHT, M=MANUAL STARTER, K=KEY SWITCH 3 OR 4 WAY, AS NOTED PANIC BUTTON (CONTROL AS SHOWN) MOTION SENSOR, WALL MOUNT +48" MOTION SENSOR CEILING MOUNT RELAY FOR MOTION SENSOR JUNCTION BOX (SIZE AS REQUIRED) DUPLEX RECEPTACLE +15" DUPLEX RECEPTACLE WEATHER PROOF DOUBLE DUPLEX RECEPTACLE (GFI +44" IN RESTROOMS) DUPLEX RECEPTACLE +48" OR COUNTER HEIGHT (GFI +44" IN RESTROOMS) DUPLEX RECEPTACLE ISOLATED FLOOR BOX (RECEPTACLE, DATA, & PHONE AS SHOWN) TELEPHONE RING WITH 3/4" CONDUIT TO CEILING DATA RING WITH 3/4" CONDUIT TO CEILING THERMOSTAT RING WITH 1/2" CONDUIT TO CEILING CONDUIT IN WALL, CEILING, OR EXPOSED CONDUIT UNDERGROUND 1/2" CONDUIT 2 #12 WIRES (1/2"c.-2 #12 cu. OR AS NOTED) 1/2"c.-3 #12 cu. OR (AS NOTED) 1/2"c.-4 #12 cu. OR (AS NOTED) COMBINATION STARTER, RATING AS NOTED ELECTRICAL NOTES & SPECIFICATIONS E-0 THOMAS R .STEENO STATE OF CAL IFORNIA C-26448 L ICENSED ARCHITECT REN. 2 /28/25 THESE DOCUMENTS AND THE DESIGN AND IDEAS INCORPORATED HEREIN, AS AN INSTRUMENT OF A PROFESSIONAL SERVICE, ARE THE SOLE PROPERTY OF STEENO DESIGN STUDIO INC. ANY USE, IN WHOLE OR IN PART FOR WHICH THEY WERE NOT PROVIDED SHALL BE UNLAWFUL P H O N E ( 7 6 0 ) 2 4 4 - 5 0 0 1 F A X ( 7 6 0 ) 2 4 4 - 1 9 4 8 1 1 7 7 4 H E S P E R I A R O A D , S U I T E B H E S P E R I A , C A . 9 2 3 4 5 THESE PLANS SHALL COMPLY WITH THE 2022 CALIFORNIA BUILDING CODE WHICH ADOPTS THE 2022 CMC, 2022 CPC, 2022 CEC, 2022 CGC, 2022 CRC AND THE 2022 ENERGY STANDARDS R E V I S I O N S DATE FINISHED w w w . s t e e n o d e s i g n . c o m PR O J E C T : JOB NO. SHEET NAME: PAGE IN C . D E S I G N S T U D I O A R C H I T E C T U R E D E S I G N P L A N N I N G S T E E N O GENERAL NOTES CBA S C H E D U L E W A T T SL O C A T I O N REC.LTG.MISC. NO. OUTLETS P A N E L POLEAMP CKT. BKR. NO. V O L A T G E CKT. TOTAL WATTS : 1 3 5 9 7 13 11 17 15 21 25 27 23 19 31 29 35 33 37 39 41 2 CKT. NO. CKT. BKR. AMPPOLE NO. OUTLETS MISC.LTG.REC. L O C A T I O N 40 42 36 38 32 34 30 28 24 26 20 22 18 16 14 12 8 10 4 6 CBA S C H E D U L E W A T T SL O C A T I O N REC.LTG.MISC. NO. OUTLETS P A N E L POLEAMP CKT. BKR. NO. V O L A T G E CKT. TOTAL WATTS : 1 3 5 9 7 13 11 17 15 21 25 27 23 19 29 2 CKT. NO. CKT. BKR. AMPPOLE NO. OUTLETS MISC.LTG.REC. L O C A T I O N 30 28 24 26 20 22 18 16 14 12 8 10 4 6 S: \ 2 0 2 4 A p r o j e c t s \ 0 2 - C o m m e r c i a l \ L - P \ 2 0 - M a i d a S a n t a A n a \ E - 0 E l e c t S p e c s _ M a i d a _ S a n t a A n a F a i r v i e w S t . . d w g , 8 / 2 1 / 2 0 2 4 9 : 0 6 : 2 2 A M , D W G T o P D F . p c 3 2413 S Fairview St Unit #A9/20/2024 SA N T A A N A B H L , I N C . BE V E R A G E H O U S E L I Q U O R # 2 5 C24-L20 JUNE 2024 PR O J E C T A D D R E S S : 27 1 3 S . F A I R V I E W S T . , SA N T A A N A , C A . 9 2 7 0 4 CO N T A C T I N F O : UP L A N D B H L I N C . MA R K M A I D A 1 B&S 08-12-2024 POWER PLAN E-1 THOMAS R .STEENO STATE OF CAL IFORNIA C-26448 L ICENSED ARCHITECT REN. 2 /28/25 THESE DOCUMENTS AND THE DESIGN AND IDEAS INCORPORATED HEREIN, AS AN INSTRUMENT OF A PROFESSIONAL SERVICE, ARE THE SOLE PROPERTY OF STEENO DESIGN STUDIO INC. ANY USE, IN WHOLE OR IN PART FOR WHICH THEY WERE NOT PROVIDED SHALL BE UNLAWFUL P H O N E ( 7 6 0 ) 2 4 4 - 5 0 0 1 F A X ( 7 6 0 ) 2 4 4 - 1 9 4 8 1 1 7 7 4 H E S P E R I A R O A D , S U I T E B H E S P E R I A , C A . 9 2 3 4 5 THESE PLANS SHALL COMPLY WITH THE 2022 CALIFORNIA BUILDING CODE WHICH ADOPTS THE 2022 CMC, 2022 CPC, 2022 CEC, 2022 CGC, 2022 CRC AND THE 2022 ENERGY STANDARDS R E V I S I O N S DATE FINISHED w w w . s t e e n o d e s i g n . c o m PR O J E C T : JOB NO. SHEET NAME: PAGE IN C . D E S I G N S T U D I O A R C H I T E C T U R E D E S I G N P L A N N I N G S T E E N O NO R T H 55'-0" 55 ' - 0 " 46 ' - 3 " 4' - 2 " 4' - 7 " 55'-0" 6'-9"14'-0"34'-3" 6'-8"27'-7" 55 ' - 0 " 7' - 1 " 47 ' - 1 1 " 6'-3" x 6'-7" EX. CLG. RESTROOM 41'-0" x 7'-9" EX. CLG. UTILITY RM./ STORAGE 5'-8" x 3'-8" EX. CLG. OFFICE 37'-3" x 31'-9" EX. CLG. C-STORE 8'-4" x 27'-0" EX. CLG. CASHIER EX. WALK-IN COOLER PROPOSED WALK-IN COOLER EX. 3'-0" x 24'-0" GONDOLA FLOOR PLAN SCALE: 1/4" = 1'-0" COOLER SPECS. EX. 3'-0" x 24'-0" GONDOLA EX. 3'-0" x 24'-0" GONDOLA EX . L I Q U O R D I S P L A Y ELEC. PANEL 'A' ELEC. PANEL 'B' MS MS MS MS MS 33'-5" x 13'-3" EXISTING (14) 28" COOLER DOORS EXISTING (1) 36" DELIVERY DOORS (11) 30" COOLER DOORS EXISTING COOLER TO BE REPLACE BY NEW PROP. COOLER OF SAME SIZE AND SAME NUMBER OF DOORS PROP. 7'-0" x 32'-0" COOLER W/ (11) 30" x 79" COOLER DOORS 2 DOOR FREEZER TO REPLACE OLD FREEZER LINE OF OLD COOLER WALL TO BE REMOVED TO CONNECT EX. RENOVATED COOLER AND NEW PROPOSED COOLER EX. REACH-IN FREEZER EX. REACH-IN FREEZER EX. REACH-IN FREEZER EX. SANDWICH DISPLAY S: \ 2 0 2 4 A p r o j e c t s \ 0 2 - C o m m e r c i a l \ L - P \ 2 0 - M a i d a S a n t a A n a \ E - 1 F l o o r P l a n _ S a n t a A n a . d w g , 8 / 2 2 / 2 0 2 4 8 : 4 2 : 3 4 A M , D W G T o P D F . p c 3 2413 S Fairview St Unit #A9/20/2024 N. T. S. SINGLE LINE DIAGRAM D) C O L D W A T E R G R O U N D I N G H A S T O B E A T T A C H E D W I T H I N E L E C T R O D E S T H A T A R E A P A R T O F T H E G R O U N D I N G E L E C T R O D E 1 . P R O V I D E A L L R E Q U I R E D C O M P O N E N T S F O R A C O M P L E T E I N T E R I O R M E T A L W A T E R P I P I N G L O C A T E D M O R E T H A N 5 F T . ( 1 . 5 2 M ) F R O M T H E P O I N T O F E N T R A N C E T O T H E B U I L D I N G E L E C T R O D E S Y S T E M O R A S A C O N D U C T O R T O I N T E R C O N N E C T S Y S T E M . E X C E P T W H E N E X C E P T I O N N o . 2 A P P L I E S . A T T A C H S E R V I C E G R O U N D I N G E L E C T R O D E S P E R T H E F O L L O W I N G : L O C A T E D W I T H I N O R N E A R T H E B O T T O M O F A C O N C R E T E F O U N D A T I O N O R F O O T I N G T H A T I S I N D I R E C T C O N T A C T A) M E T A L U N D E R G R O U N D W A T E R P I P E I N D I R E C T C O N T A C T C) A N E L E C T R O D E E N C A S E D B Y A T L E A S T 2" O F C O N C R E T E . 5 ' F E E T O F E N T R A N C E I N T O B U I L D I N G P E R N . E . C . . W I T H T H E E A R T H . " G R O U N D E L E C T R O D E S Y S T E M " A S P E R N E C. 2 5 0 - 5 0 . S H A L L N O T B E U S E D A S A P A R T O F T H E G R O U N D I N G W I T H T H E E A R T H F O R 1 0 ' F E E T . C O N S I S T I N G O F A T L E A S T 2 0 ' F E E T O F 1/2 " R E B A R O R 2 0 ' O F B A R E C O P P E R N O T S M A L L E R T H E N # 4 . O R S I Z E P E R N E C . 2 5 0 - 9 4 . B) T H E M E T A L F R A M E ( T R U S S E S ) O F T H E B U I L D I N G . 2. G R O U N D A L L T R A N S F O R M E R ' S P E R N E C . 2 5 0 - 3 0 ( 3 ) GROUNDING NOTES BRANCH OVER CURRENT DEVICES SHALL BE U.L. SERIES RATED w / THE UPSTREAM FEEDER DEVICES @ A MINIMUM OF ( E ) 10 K.A.I.C. . ( EQUIPMENT SHALL BE MARKED " CAUTION SERIES RATED SYSTEM FEEDER DEVICE'S SHALL BE U.L. SERIES RATED w / THE UPSTREAM MAIN DEVICE @ A MINIMUM OF ( E ) 10 K.A.I.C. . ( EQUIPMENT SHALL BE MARKED " CAUTION SERIES RATED SYSTEM" ) 1 2 A AVAILABLE . IDENTIFIED REPLACEMENT COMPONENT REQUIRED " ) CIRCUIT VIA TIMER CONTROL PANEL VIA CONTACTORS AS REQUIRED - CIRCUIT VIA 20A - 600V. - (POLE AS REQUIRED) LIGHTING CONTACTOR w / 120V. ON ROOF FOR CONTROL. DIRECT ELECTRIC EYE TOWARDS NORTH. COIL IN SEPARATE NEMA I ENCLOSURE. INSTALL 600w. - 120V. - 1 / W. P. PHOTOCELL PROVIDE CIRCUIT BREAKER "LOCK - ON" DEVICE. CIRCUIT BREAKER TO BE "SWITCH - RATED". PROVIDED BY OWNER . MAIN SWITCH LOAD SCHEDULE TOTAL [ = 213 AMPS @ 208V.-3Ø ] 76.5 K.W. GENERAL NOTES MB 3P200A 2P200A 3PA 1 1 1 N. T. S. ELEVATION 2 2 M (E) 400 A U. G. P. S. MAIN (E) "MB" 90" GRADE 400A / 3P 54" 24"30" ( E ) WEATHERPROOF ENCLOSURE ( NEMA 3R ) (E) PANEL "A" = 32.3 K.W. (E) PANEL "B" = 44.2 K.W. SA N T A A N A B H L , I N C . BE V E R A G E H O U S E L I Q U O R # 2 5 C24-L20 JUNE 2024 PR O J E C T A D D R E S S : 27 1 3 S . F A I R V I E W S T . , SA N T A A N A , C A . 9 2 7 0 4 CO N T A C T I N F O : UP L A N D B H L I N C . MA R K M A I D A 1 B&S 08-12-2024 THOMAS R .STEENO STATE OF CAL IFORNIA C-26448 L ICENSED ARCHITECT REN. 2 /28/25 THESE DOCUMENTS AND THE DESIGN AND IDEAS INCORPORATED HEREIN, AS AN INSTRUMENT OF A PROFESSIONAL SERVICE, ARE THE SOLE PROPERTY OF STEENO DESIGN STUDIO INC. ANY USE, IN WHOLE OR IN PART FOR WHICH THEY WERE NOT PROVIDED SHALL BE UNLAWFUL P H O N E ( 7 6 0 ) 2 4 4 - 5 0 0 1 F A X ( 7 6 0 ) 2 4 4 - 1 9 4 8 1 1 7 7 4 H E S P E R I A R O A D , S U I T E B H E S P E R I A , C A . 9 2 3 4 5 THESE PLANS SHALL COMPLY WITH THE 2022 CALIFORNIA BUILDING CODE WHICH ADOPTS THE 2022 CMC, 2022 CPC, 2022 CEC, 2022 CGC, 2022 CRC AND THE 2022 ENERGY STANDARDS R E V I S I O N S DATE FINISHED w w w . s t e e n o d e s i g n . c o m PR O J E C T : JOB NO. SHEET NAME: PAGE IN C . D E S I G N S T U D I O A R C H I T E C T U R E D E S I G N P L A N N I N G S T E E N O EXISTING SINGLE LINE DIAGRAM E-2 & NEW T.I. MODIFICATIONS S: \ 2 0 2 4 A p r o j e c t s \ 0 2 - C o m m e r c i a l \ L - P \ 2 0 - M a i d a S a n t a A n a \ E - 2 . 0 ( E ) I - L I n e _ S a n t a A n a . d w g , 8 / 2 1 / 2 0 2 4 9 : 0 8 : 1 5 A M , D W G T o P D F . p c 3 2413 S Fairview St Unit #A9/20/2024 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 2413 S Fairview St Unit #A9/20/2024 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 2413 S Fairview St Unit #A9/20/2024