HomeMy WebLinkAbout2413 S Fairview St Unit #A - PlanTO OBTAIN THE PERMITS TO REPLACE THE EXISTING WALK-IN
COOLER SECTION OF 14 COOLERS WITH 28" DOORS (REPLACE LIKE
FOR LIKE). TO PROPOSE 11 NEW WALK-IN COOLERS WITH 30"
DOORS. REMOVE THE WALL BETWEEN THE EXISTING AND
PROPOSED COOLERS CREATING ONE BIG WALK-IN COOLER AREA.
TO REPLACE THE EX. 2 DOOR FREEZER WITH NEW PROP. 2 DOOR
FREEZER (REPLACE LIKE FOR LIKE).
SA
N
T
A
A
N
A
B
H
L
,
I
N
C
.
BE
V
E
R
A
G
E
H
O
U
S
E
L
I
Q
U
O
R
#
2
5
C24-L20
JUNE 2024
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
27
1
3
S
.
F
A
I
R
V
I
E
W
S
T
.
,
SA
N
T
A
A
N
A
,
C
A
.
9
2
7
0
4
CO
N
T
A
C
T
I
N
F
O
:
UP
L
A
N
D
B
H
L
I
N
C
.
MA
R
K
M
A
I
D
A
1 B&S 08-12-2024
THOMAS R .STEENO
STATE OF CAL IFORNIA
C-26448
LICENSED ARCHITECT
REN.2 /28/25
THESE DOCUMENTS AND THE
DESIGN AND IDEAS
INCORPORATEDHEREIN, AS AN
INSTRUMENTOF A
PROFESSIONAL SERVICE,ARE
THE SOLE PROPERTY OF
STEENO DESIGN STUDIO INC.
ANY USE, IN WHOLE OR IN PART
FOR WHICH THEY WERE NOT
PROVIDED SHALL BE UNLAWFUL
P
H
O
N
E
(
7
6
0
)
2
4
4
-
5
0
0
1
F
A
X
(
7
6
0
)
2
4
4
-
1
9
4
8
1
1
7
7
4
H
E
S
P
E
R
I
A
R
O
A
D
,
S
U
I
T
E
B
H
E
S
P
E
R
I
A
,
C
A
.
9
2
3
4
5
THESEPLANS SHALL COMPLY
WITH THE 2022 CALIFORNIA
BUILDING CODE WHICH ADOPTS
THE 2022 CMC, 2022 CPC,2022
CEC, 2022 CGC, 2022 CRC AND
THE 2022 ENERGY STANDARDS
R E V I S I O N S
DATE FINISHED
w
w
w
.
s
t
e
e
n
o
d
e
s
i
g
n
.
c
o
m
PR
O
J
E
C
T
:
JOB NO.
SHEET NAME:
PAGE
IN
C
.
D
E
S
I
G
N
S
T
U
D
I
O
A
R
C
H
I
T
E
C
T
U
R
E
D
E
S
I
G
N
P
L
A
N
N
I
N
G
S
T
E
E
N
O
NO
R
T
H
SITE PLAN
A-0
S FAIRVIEW ST.
WA
R
N
E
R
A
V
E
.
EX. BUILDING
NOT A PART
EX. BUILDING
NOT A PART
EX. BUILDING
NOT A PART
BEVERAGE HOUSE
LIQUOR # 25 AREA OF PROP.
WORK @ HATCH AREA
STEENO DESIGN STUDIO, INC.
ARCHITECT: TOM STEENO
11774 HESPERIA RD. SUITE B-1
PH: 760.244.5001 FX: 760.244.1948
MARK MAIDA
UPLAND BHL INC.
13302 RANCHERO RD. 92344
PH: (760) 964-7936
APPLICANT / OWNER:
PROJECT DATA
1
V - B
STORIES:
OCCUPANCY'S:
CONSTRUCTION TYPE:
ZONE:C-4
B
NOEXISTING FIRE SPRINKLERS:
A.P.N.:
BUILDING CODE: ................................................
** THESE PLANS SHALL COMPLY W/ SANTA ANA MUNICIPAL CODE AND 2022 EDITION OF THE
CALIFORNIA BUILDING CODE WHICH ADOPTS THE 2018 IBC, 2022 CMC, 2022 CPC AND THE 2022
CEC AND CALIFORNIA AMENDMENTS.
ELECTRICAL CODE: ...........................................
2022 CALIF. BUILDING CODE (C.B.C.)
2022 CALIF. ELECTRICAL CODE (C.E.C.)
MECHANICAL CODE: ......................................... 2022 CALIF. MECHANICAL CODE (C.M.C.)
PLUMBING CODE: .............................................. 2022 CALIF. PLUMBING CODE (C.P.C.)
ENERGY CODE (TITLE 24. PT. 6): ..................... 2022 CALIF. ENERGY STANDARDS
GREEN CODE (TITLE 24. PART 11): ................. 2022 CALIF. GREEN BUILDING STANDARDS (C.G.C.)
FIRE CODE: ........................................................ 2022 CAL. FIRE CODE (C.F.C.)
APPLICABLE CODES
0 15 30 60 120
SCALE = 1:30
SCOPE OF WORK
VICINITY MAP
NORTH
PROJECT
LOCATION
NOTES:
THIS FACILITY TO MAINTAIN THE SAME STORE SIZE AND
HOURS OF OPERATION
W SEGERSTROM
AVE.
W WARNER AVE.
W MACARTHUR
BLVD.S
F
A
I
R
V
I
E
W
S
T
.
S
R
A
I
T
T
S
T
.
S
B
R
I
S
T
O
L
S
T
.
S
B
E
A
R
S
T
.
S
H
A
R
B
O
R
BL
V
D
.
ARCHITECT /
REPRESENTATIVE:
9505-051-16
SITE PLAN
SCALE: 1:30
SHEET INDEX
01 - A-1
05 - E-0
05 - E-1
05 - E-2
01 - A-0 TITLE SHEET - SITE PLAN
FLOOR PLAN
ELECTRICAL SPECS.
FLOOR PLAN
ELECTRICAL FLOOR PLAN
1
1
S:
\
2
0
2
4
A
p
r
o
j
e
c
t
s
\
0
2
-
C
o
m
m
e
r
c
i
a
l
\
L
-
P
\
2
0
-
M
a
i
d
a
S
a
n
t
a
A
n
a
\
A
-
0
S
i
t
e
P
l
a
n
_
S
a
n
t
a
A
n
a
.
d
w
g
,
9
/
3
/
2
0
2
4
1
1
:
0
9
:
3
0
A
M
,
D
W
G
T
o
P
D
F
.
p
c
3
Bldg#103120201
APPROVALS:
PLNG - PRaj
BLDG - CSG Consultants
2413 S Fairview St Unit
#A9/20/2024
SA
N
T
A
A
N
A
B
H
L
,
I
N
C
.
BE
V
E
R
A
G
E
H
O
U
S
E
L
I
Q
U
O
R
#
2
5
C24-L20
JUNE 2024
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
27
1
3
S
.
F
A
I
R
V
I
E
W
S
T
.
,
SA
N
T
A
A
N
A
,
C
A
.
9
2
7
0
4
CO
N
T
A
C
T
I
N
F
O
:
UP
L
A
N
D
B
H
L
I
N
C
.
MA
R
K
M
A
I
D
A
1 B&S 08-12-2024
FLOOR PLAN
A-1
THOMAS R .STEENO
STATE OF CAL IFORNIA
C-26448
L
ICENSED ARCHITECT
REN. 2 /28/25
THESE DOCUMENTS AND THE
DESIGN AND IDEAS
INCORPORATED HEREIN, AS AN
INSTRUMENT OF A
PROFESSIONAL SERVICE, ARE
THE SOLE PROPERTY OF
STEENO DESIGN STUDIO INC.
ANY USE, IN WHOLE OR IN PART
FOR WHICH THEY WERE NOT
PROVIDED SHALL BE UNLAWFUL
P
H
O
N
E
(
7
6
0
)
2
4
4
-
5
0
0
1
F
A
X
(
7
6
0
)
2
4
4
-
1
9
4
8
1
1
7
7
4
H
E
S
P
E
R
I
A
R
O
A
D
,
S
U
I
T
E
B
H
E
S
P
E
R
I
A
,
C
A
.
9
2
3
4
5
THESE PLANS SHALL COMPLY
WITH THE 2022 CALIFORNIA
BUILDING CODE WHICH ADOPTS
THE 2022 CMC, 2022 CPC, 2022
CEC, 2022 CGC, 2022 CRC AND
THE 2022 ENERGY STANDARDS
R E V I S I O N S
DATE FINISHED
w
w
w
.
s
t
e
e
n
o
d
e
s
i
g
n
.
c
o
m
PR
O
J
E
C
T
:
JOB NO.
SHEET NAME:
PAGE
IN
C
.
D
E
S
I
G
N
S
T
U
D
I
O
A
R
C
H
I
T
E
C
T
U
R
E
D
E
S
I
G
N
P
L
A
N
N
I
N
G
S
T
E
E
N
O
NO
R
T
H
55'-0"
55
'
-
0
"
46
'
-
3
"
4'
-
2
"
4'
-
7
"
55'-0"
6'-9"14'-0"34'-3"
6'-8"27'-7"
55
'
-
0
"
7'
-
1
"
47
'
-
1
1
"
6'-3" x 6'-7"
EX. CLG.
RESTROOM
41'-0" x 7'-9"
EX. CLG.
UTILITY RM./ STORAGE
5'-8" x 3'-8"
EX. CLG.
OFFICE
37'-3" x 31'-9"
EX. CLG.
C-STORE
8'-4" x 27'-0"
EX. CLG.
CASHIER
33'-5" x 13'-3"
EX. WALK-IN COOLER
EXISTING (14) 28" COOLER DOORS
EXISTING (1) 36" DELIVERY DOORS
PROPOSED
WALK-IN
COOLER
(11) 30" COOLER
DOORS
2-DOOR FREEZER
EX. 3'-0" x 24'-0" GONDOLA
FLOOR PLAN
SCALE: 1/4" = 1'-0"
EXISTING COOLER TO BE REPLACE BY
NEW PROP. COOLER OF SAME SIZE
AND SAME NUMBER OF DOORS
PROP. 7'-0" x 32'-0"
COOLER W/ (11) 30" x 79"
COOLER DOORS
2 DOOR FREEZER TO
REPLACE OLD FREEZER
LINE OF OLD COOLER WALL TO BE
REMOVED TO CONNECT EX.
RENOVATED COOLER AND NEW
PROPOSED COOLER
COOLER SPECS.
EX. REACH-IN
FREEZER
EX. REACH-IN
FREEZER
EX. REACH-IN
FREEZER
EX. SANDWICH
DISPLAY
EX. 3'-0" x 24'-0" GONDOLA
EX. 3'-0" x 24'-0" GONDOLA
EX
.
L
I
Q
U
O
R
D
I
S
P
L
A
Y
ELEC.
PANEL 'A'
ELEC.
PANEL 'B'
LARR # 252191
1
6'
-
7
"
4'
-
0
"
4'
-
0
"
5'
-
5
"
3'-10"
30" x 48" ACCESSIBILTY
CLEAR SPACE1
1
3'
-
0
"
FLUSH FLOOR @ ENTRY
S:
\
2
0
2
4
A
p
r
o
j
e
c
t
s
\
0
2
-
C
o
m
m
e
r
c
i
a
l
\
L
-
P
\
2
0
-
M
a
i
d
a
S
a
n
t
a
A
n
a
\
A
-
1
F
l
o
o
r
P
l
a
n
_
S
a
n
t
a
A
n
a
.
d
w
g
,
8
/
2
1
/
2
0
2
4
9
:
0
5
:
5
0
A
M
,
D
W
G
T
o
P
D
F
.
p
c
3
2413 S Fairview St Unit
#A9/20/2024
SA
N
T
A
A
N
A
B
H
L
,
I
N
C
.
BE
V
E
R
A
G
E
H
O
U
S
E
L
I
Q
U
O
R
#
2
5
C24-L20
JUNE 2024
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
27
1
3
S
.
F
A
I
R
V
I
E
W
S
T
.
,
SA
N
T
A
A
N
A
,
C
A
.
9
2
7
0
4
CO
N
T
A
C
T
I
N
F
O
:
UP
L
A
N
D
B
H
L
I
N
C
.
MA
R
K
M
A
I
D
A
1 B&S 08-12-2024
FLOOR BOX (DUPLEX RECEPTACLE ONLY)
COMBINATION PHONE & DATA RING WITH 3/4" CONDUIT TO CEILING
ELECTRICAL SYMBOL LIST
RECESSED 2x4 FIXTURE 2 LAMP
RECESSED 2x4 FIXTURE 3 LAMP
RECESSED 2x4 FIXTURE 3 LAMP TANDEM WIRED
RECESSED 2x4 FIXTURE 4 LAMP
SURFACE 1x4 WRAP
RECESSED DOWN LIGHT INCANDESCENT
RECESSED DOWN LIGHT FLUORSCENT
SHOE BOX STYLE FIXTURE (WATTAGE AS NOTED)
WALL PACK (WATTAGE AS NOTED)
EXIT SIGN (ARROWS AS NOTED)
NIGHT LIGHT (ON 24 HOURS)
INS
DISCONNECT SWITCH, RATING AS NOTED
,,P M K
S
S S S
S
3 4S , S
CONDUIT DOWN
CONDUIT UP
T
EXHAUST FAN (CONNECT ONLY)
SINGLE POLE SWITCH 48" TO TOP (RESTROOMS +44" TO TOP)
SWITCH WITH P=PILOT LIGHT, M=MANUAL STARTER, K=KEY
SWITCH 3 OR 4 WAY, AS NOTED
PANIC BUTTON (CONTROL AS SHOWN)
MOTION SENSOR, WALL MOUNT +48"
MOTION SENSOR CEILING MOUNT
RELAY FOR MOTION SENSOR
JUNCTION BOX (SIZE AS REQUIRED)
DUPLEX RECEPTACLE +15"
DUPLEX RECEPTACLE WEATHER PROOF
DOUBLE DUPLEX RECEPTACLE (GFI +44" IN RESTROOMS)
DUPLEX RECEPTACLE +48" OR COUNTER HEIGHT (GFI +44" IN RESTROOMS)
DUPLEX RECEPTACLE ISOLATED
FLOOR BOX (RECEPTACLE, DATA, & PHONE AS SHOWN)
TELEPHONE RING WITH 3/4" CONDUIT TO CEILING
DATA RING WITH 3/4" CONDUIT TO CEILING
THERMOSTAT RING WITH 1/2" CONDUIT TO CEILING
CONDUIT IN WALL, CEILING, OR EXPOSED
CONDUIT UNDERGROUND
1/2" CONDUIT 2 #12 WIRES (1/2"c.-2 #12 cu. OR AS NOTED)
1/2"c.-3 #12 cu. OR (AS NOTED)
1/2"c.-4 #12 cu. OR (AS NOTED)
COMBINATION STARTER, RATING AS NOTED
ELECTRICAL NOTES
& SPECIFICATIONS
E-0
THOMAS R .STEENO
STATE OF CAL IFORNIA
C-26448
L
ICENSED ARCHITECT
REN. 2 /28/25
THESE DOCUMENTS AND THE
DESIGN AND IDEAS
INCORPORATED HEREIN, AS AN
INSTRUMENT OF A
PROFESSIONAL SERVICE, ARE
THE SOLE PROPERTY OF
STEENO DESIGN STUDIO INC.
ANY USE, IN WHOLE OR IN PART
FOR WHICH THEY WERE NOT
PROVIDED SHALL BE UNLAWFUL
P
H
O
N
E
(
7
6
0
)
2
4
4
-
5
0
0
1
F
A
X
(
7
6
0
)
2
4
4
-
1
9
4
8
1
1
7
7
4
H
E
S
P
E
R
I
A
R
O
A
D
,
S
U
I
T
E
B
H
E
S
P
E
R
I
A
,
C
A
.
9
2
3
4
5
THESE PLANS SHALL COMPLY
WITH THE 2022 CALIFORNIA
BUILDING CODE WHICH ADOPTS
THE 2022 CMC, 2022 CPC, 2022
CEC, 2022 CGC, 2022 CRC AND
THE 2022 ENERGY STANDARDS
R E V I S I O N S
DATE FINISHED
w
w
w
.
s
t
e
e
n
o
d
e
s
i
g
n
.
c
o
m
PR
O
J
E
C
T
:
JOB NO.
SHEET NAME:
PAGE
IN
C
.
D
E
S
I
G
N
S
T
U
D
I
O
A
R
C
H
I
T
E
C
T
U
R
E
D
E
S
I
G
N
P
L
A
N
N
I
N
G
S
T
E
E
N
O
GENERAL NOTES
CBA
S C H E D U L E
W A T T SL O C A T I O N
REC.LTG.MISC.
NO. OUTLETS
P A N E L
POLEAMP
CKT. BKR.
NO.
V O L A T G E
CKT.
TOTAL WATTS :
1
3
5
9
7
13
11
17
15
21
25
27
23
19
31
29
35
33
37
39
41
2
CKT.
NO.
CKT. BKR.
AMPPOLE
NO. OUTLETS
MISC.LTG.REC.
L O C A T I O N
40
42
36
38
32
34
30
28
24
26
20
22
18
16
14
12
8
10
4
6
CBA
S C H E D U L E
W A T T SL O C A T I O N
REC.LTG.MISC.
NO. OUTLETS
P A N E L
POLEAMP
CKT. BKR.
NO.
V O L A T G E
CKT.
TOTAL WATTS :
1
3
5
9
7
13
11
17
15
21
25
27
23
19
29
2
CKT.
NO.
CKT. BKR.
AMPPOLE
NO. OUTLETS
MISC.LTG.REC.
L O C A T I O N
30
28
24
26
20
22
18
16
14
12
8
10
4
6
S:
\
2
0
2
4
A
p
r
o
j
e
c
t
s
\
0
2
-
C
o
m
m
e
r
c
i
a
l
\
L
-
P
\
2
0
-
M
a
i
d
a
S
a
n
t
a
A
n
a
\
E
-
0
E
l
e
c
t
S
p
e
c
s
_
M
a
i
d
a
_
S
a
n
t
a
A
n
a
F
a
i
r
v
i
e
w
S
t
.
.
d
w
g
,
8
/
2
1
/
2
0
2
4
9
:
0
6
:
2
2
A
M
,
D
W
G
T
o
P
D
F
.
p
c
3
2413 S Fairview St Unit
#A9/20/2024
SA
N
T
A
A
N
A
B
H
L
,
I
N
C
.
BE
V
E
R
A
G
E
H
O
U
S
E
L
I
Q
U
O
R
#
2
5
C24-L20
JUNE 2024
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
27
1
3
S
.
F
A
I
R
V
I
E
W
S
T
.
,
SA
N
T
A
A
N
A
,
C
A
.
9
2
7
0
4
CO
N
T
A
C
T
I
N
F
O
:
UP
L
A
N
D
B
H
L
I
N
C
.
MA
R
K
M
A
I
D
A
1 B&S 08-12-2024
POWER PLAN
E-1
THOMAS R .STEENO
STATE OF CAL IFORNIA
C-26448
L
ICENSED ARCHITECT
REN. 2 /28/25
THESE DOCUMENTS AND THE
DESIGN AND IDEAS
INCORPORATED HEREIN, AS AN
INSTRUMENT OF A
PROFESSIONAL SERVICE, ARE
THE SOLE PROPERTY OF
STEENO DESIGN STUDIO INC.
ANY USE, IN WHOLE OR IN PART
FOR WHICH THEY WERE NOT
PROVIDED SHALL BE UNLAWFUL
P
H
O
N
E
(
7
6
0
)
2
4
4
-
5
0
0
1
F
A
X
(
7
6
0
)
2
4
4
-
1
9
4
8
1
1
7
7
4
H
E
S
P
E
R
I
A
R
O
A
D
,
S
U
I
T
E
B
H
E
S
P
E
R
I
A
,
C
A
.
9
2
3
4
5
THESE PLANS SHALL COMPLY
WITH THE 2022 CALIFORNIA
BUILDING CODE WHICH ADOPTS
THE 2022 CMC, 2022 CPC, 2022
CEC, 2022 CGC, 2022 CRC AND
THE 2022 ENERGY STANDARDS
R E V I S I O N S
DATE FINISHED
w
w
w
.
s
t
e
e
n
o
d
e
s
i
g
n
.
c
o
m
PR
O
J
E
C
T
:
JOB NO.
SHEET NAME:
PAGE
IN
C
.
D
E
S
I
G
N
S
T
U
D
I
O
A
R
C
H
I
T
E
C
T
U
R
E
D
E
S
I
G
N
P
L
A
N
N
I
N
G
S
T
E
E
N
O
NO
R
T
H
55'-0"
55
'
-
0
"
46
'
-
3
"
4'
-
2
"
4'
-
7
"
55'-0"
6'-9"14'-0"34'-3"
6'-8"27'-7"
55
'
-
0
"
7'
-
1
"
47
'
-
1
1
"
6'-3" x 6'-7"
EX. CLG.
RESTROOM
41'-0" x 7'-9"
EX. CLG.
UTILITY RM./ STORAGE
5'-8" x 3'-8"
EX. CLG.
OFFICE
37'-3" x 31'-9"
EX. CLG.
C-STORE
8'-4" x 27'-0"
EX. CLG.
CASHIER
EX. WALK-IN COOLER
PROPOSED
WALK-IN
COOLER
EX. 3'-0" x 24'-0" GONDOLA
FLOOR PLAN
SCALE: 1/4" = 1'-0"
COOLER SPECS.
EX. 3'-0" x 24'-0" GONDOLA
EX. 3'-0" x 24'-0" GONDOLA
EX
.
L
I
Q
U
O
R
D
I
S
P
L
A
Y
ELEC.
PANEL 'A'
ELEC.
PANEL 'B'
MS
MS
MS
MS
MS
33'-5" x 13'-3"
EXISTING (14) 28" COOLER DOORS
EXISTING (1) 36" DELIVERY DOORS
(11) 30" COOLER
DOORS
EXISTING COOLER TO BE REPLACE BY
NEW PROP. COOLER OF SAME SIZE
AND SAME NUMBER OF DOORS
PROP. 7'-0" x 32'-0"
COOLER W/ (11) 30" x 79"
COOLER DOORS
2 DOOR FREEZER TO
REPLACE OLD FREEZER
LINE OF OLD COOLER WALL TO BE
REMOVED TO CONNECT EX.
RENOVATED COOLER AND NEW
PROPOSED COOLER
EX. REACH-IN
FREEZER
EX. REACH-IN
FREEZER
EX. REACH-IN
FREEZER
EX. SANDWICH
DISPLAY
S:
\
2
0
2
4
A
p
r
o
j
e
c
t
s
\
0
2
-
C
o
m
m
e
r
c
i
a
l
\
L
-
P
\
2
0
-
M
a
i
d
a
S
a
n
t
a
A
n
a
\
E
-
1
F
l
o
o
r
P
l
a
n
_
S
a
n
t
a
A
n
a
.
d
w
g
,
8
/
2
2
/
2
0
2
4
8
:
4
2
:
3
4
A
M
,
D
W
G
T
o
P
D
F
.
p
c
3
2413 S Fairview St Unit
#A9/20/2024
N. T. S.
SINGLE LINE DIAGRAM
D) C O L D W A T E R G R O U N D I N G H A S T O B E A T T A C H E D W I T H I N
E L E C T R O D E S T H A T A R E A P A R T O F T H E G R O U N D I N G E L E C T R O D E
1 . P R O V I D E A L L R E Q U I R E D C O M P O N E N T S F O R A C O M P L E T E
I N T E R I O R M E T A L W A T E R P I P I N G L O C A T E D M O R E T H A N 5 F T .
( 1 . 5 2 M ) F R O M T H E P O I N T O F E N T R A N C E T O T H E B U I L D I N G
E L E C T R O D E S Y S T E M O R A S A C O N D U C T O R T O I N T E R C O N N E C T
S Y S T E M . E X C E P T W H E N E X C E P T I O N N o . 2 A P P L I E S . A T T A C H
S E R V I C E G R O U N D I N G E L E C T R O D E S P E R T H E F O L L O W I N G :
L O C A T E D W I T H I N O R N E A R T H E B O T T O M O F A C O N C R E T E
F O U N D A T I O N O R F O O T I N G T H A T I S I N D I R E C T C O N T A C T
A) M E T A L U N D E R G R O U N D W A T E R P I P E I N D I R E C T C O N T A C T
C) A N E L E C T R O D E E N C A S E D B Y A T L E A S T 2" O F C O N C R E T E .
5 ' F E E T O F E N T R A N C E I N T O B U I L D I N G P E R N . E . C . .
W I T H T H E E A R T H .
" G R O U N D E L E C T R O D E S Y S T E M " A S P E R N E C. 2 5 0 - 5 0 .
S H A L L N O T B E U S E D A S A P A R T O F T H E G R O U N D I N G
W I T H T H E E A R T H F O R 1 0 ' F E E T .
C O N S I S T I N G O F A T L E A S T 2 0 ' F E E T O F 1/2 " R E B A R O R 2 0 ' O F B A R E C O P P E R N O T S M A L L E R T H E N # 4 . O R S I Z E P E R N E C . 2 5 0 - 9 4 .
B) T H E M E T A L F R A M E ( T R U S S E S ) O F T H E B U I L D I N G .
2. G R O U N D A L L T R A N S F O R M E R ' S P E R N E C . 2 5 0 - 3 0 ( 3 )
GROUNDING NOTES
BRANCH OVER CURRENT DEVICES SHALL BE U.L. SERIES RATED w / THE UPSTREAM FEEDER DEVICES
@ A MINIMUM OF ( E ) 10 K.A.I.C. . ( EQUIPMENT SHALL BE MARKED " CAUTION SERIES RATED SYSTEM
FEEDER DEVICE'S SHALL BE U.L. SERIES RATED w / THE UPSTREAM MAIN DEVICE @ A MINIMUM
OF ( E ) 10 K.A.I.C. . ( EQUIPMENT SHALL BE MARKED " CAUTION SERIES RATED SYSTEM" )
1
2
A AVAILABLE . IDENTIFIED REPLACEMENT COMPONENT REQUIRED " )
CIRCUIT VIA TIMER CONTROL PANEL VIA CONTACTORS AS REQUIRED -
CIRCUIT VIA 20A - 600V. - (POLE AS REQUIRED) LIGHTING CONTACTOR w / 120V.
ON ROOF FOR CONTROL. DIRECT ELECTRIC EYE TOWARDS NORTH.
COIL IN SEPARATE NEMA I ENCLOSURE. INSTALL 600w. - 120V. - 1 / W. P. PHOTOCELL
PROVIDE CIRCUIT BREAKER "LOCK - ON" DEVICE.
CIRCUIT BREAKER TO BE "SWITCH - RATED".
PROVIDED BY OWNER .
MAIN SWITCH LOAD SCHEDULE
TOTAL [ = 213 AMPS @ 208V.-3Ø ] 76.5 K.W.
GENERAL NOTES
MB
3P200A
2P200A
3PA
1
1
1
N. T. S.
ELEVATION
2 2
M
(E) 400 A
U. G. P. S.
MAIN (E)
"MB"
90"
GRADE
400A / 3P
54"
24"30"
( E ) WEATHERPROOF ENCLOSURE ( NEMA 3R )
(E) PANEL "A" = 32.3 K.W.
(E) PANEL "B" = 44.2 K.W.
SA
N
T
A
A
N
A
B
H
L
,
I
N
C
.
BE
V
E
R
A
G
E
H
O
U
S
E
L
I
Q
U
O
R
#
2
5
C24-L20
JUNE 2024
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
27
1
3
S
.
F
A
I
R
V
I
E
W
S
T
.
,
SA
N
T
A
A
N
A
,
C
A
.
9
2
7
0
4
CO
N
T
A
C
T
I
N
F
O
:
UP
L
A
N
D
B
H
L
I
N
C
.
MA
R
K
M
A
I
D
A
1 B&S 08-12-2024
THOMAS R .STEENO
STATE OF CAL IFORNIA
C-26448
L
ICENSED ARCHITECT
REN. 2 /28/25
THESE DOCUMENTS AND THE
DESIGN AND IDEAS
INCORPORATED HEREIN, AS AN
INSTRUMENT OF A
PROFESSIONAL SERVICE, ARE
THE SOLE PROPERTY OF
STEENO DESIGN STUDIO INC.
ANY USE, IN WHOLE OR IN PART
FOR WHICH THEY WERE NOT
PROVIDED SHALL BE UNLAWFUL
P
H
O
N
E
(
7
6
0
)
2
4
4
-
5
0
0
1
F
A
X
(
7
6
0
)
2
4
4
-
1
9
4
8
1
1
7
7
4
H
E
S
P
E
R
I
A
R
O
A
D
,
S
U
I
T
E
B
H
E
S
P
E
R
I
A
,
C
A
.
9
2
3
4
5
THESE PLANS SHALL COMPLY
WITH THE 2022 CALIFORNIA
BUILDING CODE WHICH ADOPTS
THE 2022 CMC, 2022 CPC, 2022
CEC, 2022 CGC, 2022 CRC AND
THE 2022 ENERGY STANDARDS
R E V I S I O N S
DATE FINISHED
w
w
w
.
s
t
e
e
n
o
d
e
s
i
g
n
.
c
o
m
PR
O
J
E
C
T
:
JOB NO.
SHEET NAME:
PAGE
IN
C
.
D
E
S
I
G
N
S
T
U
D
I
O
A
R
C
H
I
T
E
C
T
U
R
E
D
E
S
I
G
N
P
L
A
N
N
I
N
G
S
T
E
E
N
O
EXISTING
SINGLE LINE DIAGRAM
E-2
& NEW T.I.
MODIFICATIONS
S:
\
2
0
2
4
A
p
r
o
j
e
c
t
s
\
0
2
-
C
o
m
m
e
r
c
i
a
l
\
L
-
P
\
2
0
-
M
a
i
d
a
S
a
n
t
a
A
n
a
\
E
-
2
.
0
(
E
)
I
-
L
I
n
e
_
S
a
n
t
a
A
n
a
.
d
w
g
,
8
/
2
1
/
2
0
2
4
9
:
0
8
:
1
5
A
M
,
D
W
G
T
o
P
D
F
.
p
c
3
2413 S Fairview St Unit
#A9/20/2024
YES NO
INSTRUCTIONS:
ORAN GE COUNTY FI RE AUTHORI TY
Plan Submittal Criteria
COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects
and RESIDENTIAL TRACT developments
· Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place.
· Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section.
· If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA.
· In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations.
· Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding
requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602.
Address Suite City
Project Scope/Business Description
1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways,
curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within
300 feet of an active or proposed oil well? Fire Master Plan (PR145)
2. Property is adjacent to a wildland area or non-irrigated native vegetation?
Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124)
3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from
an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170)
4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving
private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475)
5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000
sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable
to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless
classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration
or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses
where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories
with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285)
6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card,
button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan
depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520)
7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment;
industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible
liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium
ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations?
Special Equipment Plan (PR315, PR340-PR382)
8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft
maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if
H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240)
9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard
commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330)
10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a
commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335)
Initial each of the following two items indicating that you have read and understand the statement:
11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is
required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed
Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications.
12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located
in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327—
Initials the building department will determine specific requirements.
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name Signature
Phone Number ( ) Date / /
Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA
review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the
applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the
appropriate plans and fees for OCFA review. 10-08-14 EE
COM
2413 S Fairview St Unit
#A9/20/2024
O R A N G E C O U N T Y F I R E A U T H O R I T Y
Plan Referral Form
Required for OCFA to review plans upon the request of the Building Department when
the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”.
City / County Official Requesting Review:
City / County Reference #: Date: __________________________________
City / County: _____________________________________ E-Mail: __________________________________
Contact Name: _____________________________________ Phone #: _________________________________
Title: _____________________________________
** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. **
Reason(s) for Review:
Please describe why OCFA Plan Review is or may be required by the City/County :
OCFA COMMENTS:
No further action required on this specific plan type, based
on information provided on: ____/______/______.
Project to be taken in for OCFA Review.
Other:
Name: _________________________________________
Contact #: ______________________________________ Date: _________________________________
OCFA Authorization
Updated: 06/02/2020 rs
2413 S Fairview St Unit