Loading...
HomeMy WebLinkAbout2301 N Tustin Ave Unit #A - Plan1. THE DRAWINGS CONSTITUTE THE CONTRACT DOCUMENTS FOR CONSTRUCTION. ALL GENERAL REQUIREMENTS ARE TO BE MET AND ALL MATERIALS, FINISHES AND SYSTEMS ARE TO BE INSTALLED AND PERFORM PER SPECIFICATIONS UNLESS OTHERWISE NOTED. 2. GENERAL CONTRACTOR SHALL VISIT THE SITE, REVIEW THE BUILDING DRAWINGS AS SUBMITTED BY STARBUCKS AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO CONSTRUCTION. 3. GENERAL CONTRACTOR SHALL CONSULT WITH STARBUCKS CONSTRUCTION MANAGER TO RESOLVE ANY CHANGES, OMISSIONS OR PLAN DISCREPANCIES PRIOR TO CONSTRUCTION. 4. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH LOCAL, COUNTY, STATE AND FEDERAL CODES AND ORDINANCES. 5. GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES. 6. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY OTHER TRADES AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. DO NOT SCALE DRAWINGS. 7. GENERAL CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS, OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF THE WORK. 8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING PERMITS FOR FIRE PROTECTION. PLUMBING, MECHANICAL, AND ELECTRICAL SYSTEMS (IF SEPARATE FROM BUILDING) PRIOR TO INSTALLATION OF SUCH SYSTEMS. 9. GENERAL CONTRACTOR SHALL RETAIN ONE SET OF PERMIT PLANS ON-SITE TO DOCUMENT ALL CHANGES MADE DURING CONSTRUCTION. THE RECORD DRAWINGS SHALL BE ISSUED TO THE OWNER AT PROJECT CLOSE-OUT AS DESCRIBED IN THE GENERAL REQUIREMENTS OF THE PROJECT MANUAL. 10. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING DELIVERY OF MATERIALS FROM STARBUCKS CONTRACTED THIRD PARTY LOGISTICS DISTRIBUTION SERVICES AND VENDOR DIRECT SHIPMENTS. SEE THE PROJECT MANUAL FOR ADDITIONAL INFORMATION. 11. RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS AND EQUIPMENT IS IDENTIFIED IN THE DRAWING SCHEDULE SHEETS UNDER THE COLUMN LABELED "FURNISHED BY/RESPONSIBILITY". 12. FOR THE PURPOSE OF THE DOCUMENTS, TO “INSTALL”, SHALL MEAN TO PROVIDE ALL FASTENERS, MISCELLANEOUS HARDWARE, BLOCKING, ELECTRICAL CONNECTIONS, PLUMBING CONNECTIONS AND OTHER ITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION, UNLESS OTHERWISE NOTED. 13. ALL ITEM SUBSTITUTIONS MUST BE APPROVED BY THE STARBUCKS CONSTRUCTION MANAGER. MAILING ADDRESS: DESIGN MANAGER: STARBUCKS COFFEE COMPANY CONTACT: ISCOLINA DELGADO - CHARLIE CHANG starbuckspc@hestiaatelier.com STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH MS STOP: S-SD10 SEATTLE, WASHINGTON 98134 (206) 318-1575 CONSTRUCTION MANAGER: STARBUCKS COFFEE COMPANY CONTACT: MATT ROBITAILLE mrobitai@starbucks.com ARCHITECT OF RECORD: MEP CONSULTANT OF RECORD: PIVOT ENGINEERING CONSULTANTS CONTACT: MOSTAFA ZUBAIR (909) 610-5364 MZUBAIR@PECCUSA.COM PROJECT MANAGER: HESTIA ATELIER, LLP CONTACT: ISCOLINA DELGADO (626) 222-7669 starbuckspc@hestiaatelier.com HESTIA ATELIER, LLP CONTACT: HIDENORI IWAGAMI 3 PETERS CANYON RD. STE:110 IRVINE, CA 92606 (626) 222-7669 starbuckspc@hestiaatelier.com PROJECT SPECIALIST: STARBUCKS COFFEE COMPANY MICHELE GURLEY (714) 477-2850 mgurley@starbucks.com LEGEND: X - SHEET ISSUED R - SHEET ISSUED FOR REFERENCE AND COORDINATION ONLY SEE TITLEBLOCK FOR REVISION ISSUE DATE(S) SCOPE OF WORK INTERIOR REMODEL OF EXISTING STARBUCKS COFFEE TENANT IMPROVEMENT. SCOPE INCLUDES: - NEW CASEWORK - NEW NON-LOAD BEARING INTERIOR PARTITIONS - NEW BEVERAGE PREP EQUIPMENT - NEW PLUMBING FIXTURES - NEW FLOOR FINISH - NEW WALL FINISH - CEILING MODIFICATIONS - NEW INTERIOR LIGHTING - NEW ARTWORK - NEW INTERIOR FURNITURE - UPGRADE DRIVE-THRU WAY FINDING SIGNAGE LIKE FOR LIKE (UNDER SEPARATE PERMIT) THERE ARE NO CHANGES TO OCCUPANCY TYPE OR TOTAL SQUARE FOOTAGE OF EXISTING TENANT SPACE. CODE AUTHORITIES: CITY OF SANTA ANA MUNICPAL CODE BUILDING CODE: 2022 California Building Code PLUMBING CODE: 2022 California Plumbing Code MECHANICAL CODE: 2022 California Mechanical Code ELECTRICAL CODE: 2022 California Electrical Code ENERGY CODE:2022 California Energy Code FIRE CODE:2022 California Fire Code HEALTH CODE:2022 California Retail Food Code ACCESSIBILITY CODE: CH 11B OF 2022 CBC ZONING INFORMATION: PARCEL NUMBER: 396-141-01, 396 - 141 - 07 LEGAL DISCRIPTION: CHAPMAN TR LOT 5 BLK B E 172 FT W 202 FT S 192 FT -EX STS- TR 175 PERMITTED LAND USE: COMMERCIAL ZONING:ARTERIAL COMMERCIAL (C5) CURRENT USE:COFFEE SHOP SEPARATE SUBMITTALS: - DRIVE-THRU WAY FINDING SIGNAGE E SANTA CLARA AVE. N T U S T I N A V E . HI G H W A Y 5 5 A/C AIR CONDITIONING ACT ACOUSTICAL CEILING TILE ADJ ADJUSTABLE AFF ABOVE FINISHED FLOOR AMP AMPERE ARCH ARCHITECT BOH BACK OF HOUSE CAB CABINET CL CENTER LINE CLG CEILING CM STARBUCKS CONSTRUCTION MANAGER CTR CENTER CX COMMISSIONING CXA COMMISSIONING AGENT DEG DEGREE DET DETAIL DIA DIAMETER DIM DIMENSION DM STARBUCKS DESIGN MANAGER DN DOWN EA EACH EL ELEVATION EQ EQUAL EXIST EXISTING EXT EXTERIOR FF&E FURNITURE, FIXTURE, AND EQUIPMENT FLR FLOOR FOH FRONT OF HOUSE FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FOIO FURNISHED BY OWNER INSTALLED BY OWNER FT FOOT/FEET G GROUND GC GENERAL CONTRACTOR GWB GYPSUM WALLBOARD HC HOLLOW CORE HDW HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HT HEIGHT HVAC HEATING, VENTILATING AND AIR CONDITIONING I.D. INSIDE DIAMETER LEED LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN LL LANDLORD LV LOW VOLTAGE MAX MAXIMUM MEP "MECHANICAL, ELECTRICAL AND PLUMBING" MFR MANUFACTURER MIN MINIMUM NIC NOT IN CONTRACT NL NIGHT LIGHT NTS NOT TO SCALE OC ON CENTER O.D. OUTSIDE DIAMETER PIR PASSIVE INFRARED SENSOR PLC PLACE R RADIUS REF REFERENCE REQ‘D REQUIRED REV REVISION RND ROUND SB STARBUCKS SC SOLID CORE SF SQUARE FEET SHT SHEET SIM SIMILAR SPEC SPECIFICATION SQ SQUARE TEMP TEMPORARY TYP TYPICAL UC UNDER COUNTER UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD X' XX" X N NORTH ARROW XXXX AFF XXXXXW XX Scale: X =X 0 2 4 8 GRAPHIC SCALE DATUM POINT EXTERIOR ELEVATION CALL-OUT INTERIOR ELEVATION CALL-OUT SECTION CALL-OUT DETAIL CALL-OUT REVISION TAG PAINT TAG DESIGN ID TAG DOOR TAG WINDOW TAG SHEET NOTE CALLOUT ABOVE FINISH FLOOR HEIGHT TAG FINISH FACE TO FINISH FACE DIMENSION REVISION CLOUD X-X-XP T XXXXX XXXXXX XXXXX D XX INTERIOR WALL TAG RESPONSIBILITY ABBREVIATIONS SB - SUPPLIED BY STARBUCKS INSTALLED BY GENERAL CONTRACTOR GC - SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR CW - SUPPLIED BY CASEWORK VENDOR - INSTALLED BY VENDOR / GENERAL CONTRACTOR VD - SUPPLIED BY VENDOR - INSTALLED BY GENERAL CONTRACTOR OCCUPANCY TYPE:B TENANT AREA:1,607 S.F. CONSTRUCTION TYPE:V-B FIRE SPRINKLER:NO NUMBER OF STORIES:1 STORAGE SHELVING REQUIRED: 96' LINEAR FEET, MIN. 18" DEEP. * 3'W X TIERS HIGH * LOWEST SHELF MIN. 6" FROM FLOOR * UNITS MOUNTED A MIN. 1" FROM ALL WALL SURFACES. * MUST MEET ALL REQUIREMENTS OF THE ORANGE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH. PROVIDED CALCULATIONS: * 3' LINEAR FEET, MIN. 18" DEEP. * LENGTH OF SHELVING UNIT X # OF TIERS X # OF UNITS = MIN. 96' OR GREATER 3LF X 5 TIERS UNITS X 11 UNITS = 165 LF > 96 LF (COMPLIES) SHEET SHEET TITLE B I D S E T P E R M I T S E T R E V I S I O N 1 R E V I S I O N 2 R E V I S I O N 3 R E V I S I O N 4 GENERAL G001 GENERAL INFORMATION G002 COMPOSITE PLAN G002A ENLARGED COMPOSITE PLAN G003 LIFE SAFETY AND ACCESSIBILITY PLAN G004 ACCESSIBILITY DETAILS G004A ACCESSIBILITY NOTES G004B ACCESSIBILITY NOTES DEMOLITION D001 ARCHITECTURAL DEMO SITE PLAN D101 DEMOLITION FLOOR PLAN D102 DEMO REFLECTED CEILING PLAN ARCHITECTURAL A001 ARCHITECTURAL SITE PLAN A002 ARCHITECTURAL SITE ACCESSIBILITY DETAILS A101 BUILDING FLOOR PLAN A102 BUILDING FLOOR PENETRATION PLAN INTERIORS I101 FF & E PLAN I102 CASEWORK PLAN I103 REFLECTED CEILING PLAN I103A REFLECTED CEILING DIMENSION PLAN I103B ENLARGED SOFFIT DIMENSION PLAN I104 FLOOR FINISH PLAN I105 WALL FINISH PLAN I201 INTERIOR FINISH ELEVATIONS I202 INTERIOR FINISH ELEVATIONS I203 INTERIOR FINISH ELEVATIONS I204 INTERIOR FINISH ELEVATIONS I205 INTERIOR FINISH ELEVATIONS I400 ENLARGED ENGINE PLAN I401 ENLARGED CASEWORK PLAN I401A ENLARGED CASEWORK PLAN I402 ENLARGED RESTROOM ACCESSIBILITY PLAN I501 INTERIOR DETAILS I501A INTERIOR DETAILS I501B INTERIOR DETAILS I501C INTERIOR DETAILS I502 CASEWORK DETAILS I502A CASEWORK DETAILS I502B CASEWORK DETAILS I502C CASEWORK DETAILS I503 FLOOR AND WALL FINISH DETAILS I504 ELECTRICAL DETAILS I504A ELECTRICAL DETAILS I504B ELECTRICAL DETAILS I504C ELECTRICAL DETAILS I504D ELECTRICAL DETAILS I505 PLUMBING DETAILS I505A PLUMBING DETAILS I505B PLUMBING DETAILS I505C PLUMBING DETAILS I601 CASEWORK AND FF&E SCHEDULES I602 INTERIOR FINISHES SCHEDULES ELECTRICAL E001 ELECTRICAL NOTES E002 ELECTRICAL SPECIFICATIONS E200 LIGHTING PLAN E210 LUTRON ONE-LINE DIAGRAM E220 LUTRON LOOP LAYOUT E300 POWER PLAN E310 ENLARGED ENGINE PLAN E320 ELECTRICAL DETAILS E330 ELECTRICAL DETAILS E500 SINGLE LINE DIAGRAM AND PANEL SCHEDULES E600 INTERIOR LIGHTING COMPLIANCE CERT E610 INTERIOR LIGHTING COMPLIANCE CERT E620 INTERIOR LIGHTING COMPLIANCE CERT MECHANICAL M001 MECHANICAL GENERAL NOTES & LEGENDS M002 MECHANICAL SCHEDULES M100 MECHANICAL FLOOR PLAN M200 MECHANICAL ROOF PLAN M300 MECHANICAL DETAILS M400 MECHANICAL T-24 MD100 MECHANICAL DEMO FLOOR PLAN PLUMBING P001 PLUMBING GENERAL NOTES & LEGENDS P002 PLUMBING SCHEDULES & CALCULATIONS P003 PLUMBING SCHEDULES & CALCULATIONS P100 PLUMBING WATER PLAN P200 PLUMBING WASTE PLAN P400 PLUMBING WATER ISOMETRIC P401 PLUMBING WASTE & VENT ISOMETRIC P500 PLUMBING DETAILS P501 PLUMBING DETAILS P502 PLUMBING DETAILS P503 PLUMBING DETAILS P504 PLUMBING DETAILS PS100 PLUMBING SITE PLAN NUMBER OF SHEETS: 83 SHEET INDEXSYMBOLS LEGEND GENERAL NOTES ABBREVIATIONS LIST PROJECT CONTACTS SITE INFORMATION BUILDING INFORMATION VICINITY PLAN STATE OF CALI F RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | A RC H I T EC TU RE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 5 / 2 0 2 4 1 0 : 2 1 : 2 7 A M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \ T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t G001 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES GENERAL INFORMATION 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 RESPONSIBILITY LEGEND DRY STORAGE REQUIREMENTS Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments A Bldg# 101119116-17 Elec# 20182680 Plmg# 30147191 APPROVALS: PLNG - PRaj BLDG - CSG Consultants ELEC - CSG Consultants PLMG - TLuka 2301 N Tustin Ave #A8/22/2024 (E) RO SYSTEM & WATER HEATER (N) MOP SINK (N) HAND SINK (N) QUEUE RAIL (N) TRASH & RECYCLE STATION G002A 1 I402 3 (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) 2-DR REACH-IN FREEZER (E) 1-DR REACH-IN FREEZER (E) 2-DR REACH-IN FRIDGE (E) DATA RACK ABOVE (N) METRO RACK (N) (E) METRO RACK (10) (E) TRASH BIN (N) ICE MACHINE / BIN/ DIVERTER (E) 2-DR REACH-IN FRIDGE (N) COLD BREW STORAGE /CART (E) WATER FILLING STATION (E) SANITIZER (N) 3-COMP SINK (E) MANAGER'S EQUIPMENT (N) MANAGER'S DESK (N) COAT HOOK (N) MIRROR 15 33 3 3 3 3 3 3 3 3 66 CLEARø 3' - 0" (E) LOCKERS (2) (N) 1-DR U/C FRIDGE (N) MIRCOWAVE (E) THAW RACK (N) 1-DR REACH-IN FREEZER ADJACENT TENANT (NIC) BACKBAR RETAIL SEATING AREA UNISEX PARTNER RESTROOM UNISEX CUSTOMER RESTROOM PARTNER / MANAGER AREA WORKROOM (N) MERCH DISPLAY 1 2 2 2 2 2 2 2 4 4 5 5 7 78 9 10 11 11 12 13 14 16 17 17 18 18 19 20 21 22 CLEARø 3' - 0" 1 CLEARø 3' - 0" CLEARø 3' - 0"(N) EMPLOYEE BREAK SINK 6 15 13 A. EXISTING ACCESSIBILE TITLE 24 PART 2 (PER 2022 CBC) COMPLIANT PATH OF TRAVEL TO REMAIN. B. ACCESSIBILE TITLE 24 PART 2 (PER 2022 CBC) COMPLIANT BATHROOM FIXTURES TO REMAIN. C. WHERE TWO EXITS OR EXIT ACCESS DOORWAYS ARE REQUIRED FROM ANY PORTION OF THE EXIT ACESS, THE EXIT DOORS OR EXIT ACCESS DOORWAYS SHALL BE PLACED IN A DISTANCE APART EQUAL TO NOT LESS THAN ONE-HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED IN A STRAIGHT LINE BETWEEN EXIT DOORS OR EXIT ACCESS DOORWAYS CBC 1015.2.1. D. ALL THRESHOLD AND FLOORING MATERIAL TRANSITIONS TO MEET ACCESSIBILITY REQUIREMENTS ON DETAIL 7 / G-004. E. ALL DOOR CLEARANCES PER DETAIL 6 / G-004 - U.N.O. COMPOSITE PLAN GENERAL NOTES COMPOSITE PLAN KEYNOTES ACCESSIBILITY KEYNOTES 1 THRESHOLDS TO BE BARRIER FREE COMPLIANT PER ALL APPLICABLE CODES. 2 BARRIER-FREE PATH OF TRAVEL. PER CBC 11B-403.5.1 3 30" (160 MM) X 48" (1220 MM) CLEAR FOR WHEELCHAIR ACCESS. 4 60" (1525 MM) DIAMETER MINIMUM TURN RADIUS FOR WHEELCHAIR ACCESS. 5 32" (815 MM) MINIMUM CLEAR AT RESTROOM DOOR. 6 POS TRANSACTION PLANE, TRASH & RECYCLE CART TOP AND HAND-OFF PLANE ARE 34 INCHES (860 MM) ABOVE THE FINISHED FLOOR FOR WHEELCHAIR ACCESSIBILITY. 7 PROVIDE BARRIER-FREE SIGNAGE AT ACCESSIBLE RESTROOMS PER ALL APPLICABLE CODES. REFER TO DETAILS 3 & 11 / SHEET G004. 8 TACTILE EXIT SIGN PER DETAIL 1/G004 9 INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN WHERE REQUIRED BY APPLICABLE LAWS OR CODES. SEE 2 / G004. GC TO PROVIDE IF NOT EXISTING 10 G.C. TO POST SIGN THAT READS "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED". THE SIGN SHALL BE IN LETTERS 1" HIGH ON A CONTRASTING BACKGROUND 11 EXISTING EXIT / EMERGENCY LIGHTS ABOVE TO REMAIN. 12 RELOCATED EXISTING FIRE EXTINGUSHER -TYPE 2A10BC PER CFC 906 13 EXTERIOR BARRIER FREE PATH OF TRAVEL -48" MIN 17 ACCESSIBLE RESTROOM -SEE SHEET G004 FOR MOUNTING HEIGHTS. 18 EXISTING EXIT DOORS TO REMAIN, REFER TO DETAILS 1,2 & 6 / SHEET G004. 20 EXISTING AIR CURTAIN ABOVE TO REMAIN. 21 NEW LUTRON PANEL ABOVE ELECTRICAL PANELS. REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION 19 EXISTING ELECTRICAL PANELS TO REMAIN. 22 NEW TRASH BIN. TO BE ORDERED BY OPERATIONS IF NEEDED 14 EXISTING DOOR IS EQIPPED WITH SURLOCK HARDWARE TO REMAIN 15 ACCESSIBLE DINING SURFACE AT 28" MIN-34" MAX AFF COMPLYING WITH SECTIONS CBC 11B-226, 902 16 GC TO POST "NO SMOKING" SIGN THAT PROHIBITS SMOKING WITHIN 25 FT FROM BUILDING ENTRIES PER CALGREEN SEC. 5 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 6 : 2 1 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t G002 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES COMPOSITE PLAN 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 1/4" = 1'-0"1ACCESSIBILITY PLAN N Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 (E) CUP LABELER (E) WARMING OVEN (2) (N) DUMP SINK (E) GRINDER(N) CLOVER VERTICA BREWER (N) HAND SINK (N) PAPER TOWEL DISPENSER (N) 1-DR U/C FRIDGE (E) 1-DR U/C FRIDGE (E) 1-DR U/C FRIDGE (E) 1-DR U/C FRIDGE (E) 1-DR U/C FRIDGE (E) WARMING FRIDGE (E) 1-DR U/C FRIDGE (E) POS EQUIPMENT (2) (E) SAFE (N) FOOD CASE (E) PASTRY CART (E) CUP CADDY (E) CUP CADDY (N) COMBO SINK (E) ESPRESSO MACHINE (N) 45LBS ICE BIN (E) CUP LABELER (N) COMBO SINK (E) ESPRESSO MACHINE (N) 45LBS ICE BIN (E) AV DIGITAL PRODUCTION MANAGER STARDAND (N) ORDER STATUS BOARD (E) NITRO TAP & BADGE (N) NITRO FRIDGE (E) NITRO GENERATOR (E) BLENDER (N) PITCHER RINSER SINK (E) BLENDER (N) HAND SINK (N) PAPER TOWEL DISPENSER 1 1 (N) COMBI OVEN (N) WARMING WALL (E) DT POS EQUIPMENTS (N) DT WINDOW (N) U/C PASTRY TRAY (E) WARMING FRIDGE (E) CUP LABELER (N) REFRESHER DISPENSE (2) G002A 4 (N) PASTRY COOLING RACK (N) PASTRY COOLING RACK (2) (E) 1-DR U/C FRIDGE (N) DT WINDOW SHELF ENLARGED COMPOSITE PLAN KEYNOTES 1 P.O.S. HANDOFF PLANES & TRASH & RECYCLE COUNTERTOPS ARE 2'-10" A.F.F. FOR WHEELCHAIR ACCESSIBILITY. A. EXISTING ACCESSIBILE TITLE 24 PART 2 (PER 2022 CBC) COMPLIANT PATH OF TRAVEL TO REMAIN. B. ACCESSIBILE TITLE 24 PART 2 (PER 2022 CBC) COMPLIANT BATHROOM FIXTURES TO REMAIN. C. WHERE TWO EXITS OR EXIT ACCESS DOORWAYS ARE REQUIRED FROM ANY PORTION OF THE EXIT ACESS, THE EXIT DOORS OR EXIT ACCESS DOORWAYS SHALL BE PLACED IN A DISTANCE APART EQUAL TO NOT LESS THAN ONE-HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED IN A STRAIGHT LINE BETWEEN EXIT DOORS OR EXIT ACCESS DOORWAYS CBC 1015.2.1. D. ALL THRESHOLD AND FLOORING MATERIAL TRANSITIONS TO MEET ACCESSIBILITY REQUIREMENTS ON DETAIL 7 / G-004. E. ALL DOOR CLEARANCES PER DETAIL 6 / G-004 - U.N.O. COMPOSITE PLAN GENERAL NOTES (N) MILK DISPENSER (N) MILK DISPENSER (N) MILK DISPENSER (N) ICE DISPENSER (E) CUP LABELER STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 5 / 2 0 2 4 1 0 : 2 1 : 3 2 A M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t G002A 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ENLARGED COMPOSITE PLAN 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 1/2" = 1'-0"11ST FLOOR -ENLARGED COMPOSITE PLAN N 1/2" = 1'-0"4ENLARGED COMPOSITE UPPER PLAN Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments A 2301 N Tustin Ave #A8/22/2024 MEANS OF EGRESS NOTES A. EVERY ROOM OR SPACE THAT IS ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT ACCESS DOORWAY. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER AUTHORIZED AGENT. CBC 1004.9 B. EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SIMILAR SPACES. CBC 1016.2 C. PANIC AND FIRE EXIT HARDWARE, WHERE INSTALLED ON DOORS IN THIS BUILDING SHALL SATISFY THE FOLLOWING CBC 1010.1.10: 1) THE ACTUATION PORTION OF THE RELEASING DEVICE SHALL EXTEND AT LEAST ONE-HALF OF THE DOOR LEAF WIDTH. 2) THE MAXIMUM UNLATCHING FORCE DOES NOT EXCEED 15 POUNDS (6.8 KG). 3) PIVOTED OR BALANCED DOORS SHALL BE OF THE PUSH-PAD TYPE WHERE PANIC HARDWARE IS REQUIRED AND THE PAD SHALL NOT EXTEND ACROSS MORE THAN ONE-HALF OF THE DOOR WIDTH, MEASURED FROM THE LATCH SIDE. 4) PANIC HARDWARE LISTED IN ACCORDANCE WITH UL 305. 5) FIRE EXIT HARDWARE LISTED IN ACCORDANCE WITH UL 10C AND UL 305. D. STRUCTURAL ELEMENTS, FIXTURES OR FURNISHINGS SHALL NOT PROJECT HORIZONTALLY FROM EITHER SIDE MORE THAN 4 INCHES (100 MM) OVER ANY WALKING SURFACE BETWEEN 27 INCHES (685 MM) AND 80 INCHES (2030 MM) ABOVE THE WALKING SURFACE. EXCEPTION: HANDRAILS SERVING STAIRS AND RAMPS ARE PERMITTED TO PROTRUDE 4 1/2 INCHES (115 MM) FROM THE WALL. CBC 1003.3.3 E. THE PATH OF EGRESS TRAVEL EXITS AND WITHIN EXITS IN THIS BUILDING SHALL BE IDENTIFIED BY EXIT SIGNS CONFORMING TO THE REQUIREMENTS OF CBC SECTION 1013.1 AND AS NOTED BELOW: 1) EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL. 2) EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE DIRECTION OF EGRESS TRAVEL. 3) NO POINT IN A CORRIDOR SHALL BE MORE THAN 100 FT (30.5 M) OR THE LISTED VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS LESS, FROM THE NEAREST VISIBLE EXIT SIGN. F. WHERE KEY OPERATED LOCKING DEVICES ARE USED, POST A SIGN ON OR ADJACENT TO THE REQUIRED MAIN EXIT DOOR WITH 1 INCH (25 MM) LETTERING STATING THAT "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED". CBC 1010.1.9.4 G. EGRESS DOORS OR GATES SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES SHALL BE INSTALLED 34 INCHES (860 MM) TO 48 INCHES (1220 MM) ABOVE FINISHED FLOOR. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. CBC 1010.1.9 H. LANDINGS SHALL BE PROVIDED ON EACH SIDE OF DOORS AND SUCH LANDING SHALL BE AT THE SAME ELEVATION ON EACH SIDE OF THE DOOR LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE DOOR AND LENGTH MEASURED IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 44 INCHES (11120 MM). CBC 1010.1.5, 1010.1.6 KEYNOTES 1 THRESHOLDS TO BE BARRIER FREE COMPLIANT PER ALL APPLICABLE CODES. 2 BARRIER-FREE PATH OF TRAVEL -CBC 11B 403.5.1 3 30" (160 MM) X 48" (1220 MM) CLEAR FOR WHEELCHAIR ACCESS. 4 60" (1525 MM) DIAMETER MINIMUM TURN RADIUS FOR WHEELCHAIR ACCESS. 5 32" (815 MM) MINIMUM CLEAR AT RESTROOM DOOR. 6 POS TRANSACTION PLANE, CONDIMENT CART TOP AND HAND-OFF PLANE ARE 34 INCHES (860 MM) ABOVE THE FINISHED FLOOR FOR WHEELCHAIR ACCESSIBILITY. 7 PROVIDE BARRIER-FREE SIGNAGE AT ACCESSIBLE RESTROOMS PER ALL APPLICABLE CODES. REFER TO DETAILS 3 & 11 / SHEET G004. 8 TACTILE EXIT SIGN PER DETAIL 1/G004 9 INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN WHERE REQUIRED BY APPLICABLE LAWS OR CODES. SEE 2 / G004. GC TO PROVIDE IF NOT EXISTING 10 G.C. TO POST SIGN THAT READS "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED". THE SIGN SHALL BE IN LETTERS 1" HIGH ON A CONTRASTING BACKGROUND 11 EXISTING EXIT / EMERGENCY LIGHTS ABOVE TO REMAIN. 12 RELOCATED EXISTING FIRE EXTINGUSHER -TYPE 2A10BC PER CFC 906 13 EXTERIOR BARRIER FREE PATH OF TRAVEL -48" MIN 14 EXISTING DOOR IS EQIPPED WITH SURLOCK HARDWARE TO REMAIN 15 ACCESSIBLE DINING SURFACE AT 28" MIN-34" MAX AFF COMPLYING WITH SECTIONS CBC 11B-226, 902 LEGEND TRAVEL DISTANCE EMERGENCY LIGHT X'-X" (XXMM) EMERGENCY EXIT LIGHT/SIGN FIRE EXTINGUISHER ADA ACCESSIBLE SEATING 36" (915MM) X 48" (1220MM) CLEAR AREA LOAD FACTOR: OCC LOAD: 64 SF 5 SEATING AREA 15 LOAD FACTOR: OCC LOAD: 350 SF 6 RETAIL 60 LOAD FACTOR: OCC LOAD: 292 SF 2 BACKBAR 200 LOAD FACTOR: OCC LOAD: 123 SF RESTROOMS / VESTIBULE 0 LOAD FACTOR: OCC LOAD: 317 SF 2 WORKROOM 200OCCUPANCY LEGEND BACKBAR MANAGER / PARTNER REST AREA RESTROOMS / VESTIBULE RETAIL SEATING AREA STANDING SPACE WORKROOM LOAD FACTOR: OCC LOAD: 122 SF 1 MANAGER / PARTNER REST AREA 150 ADJACENT TENANT (NIC) 8 911110 14 13 2 3 2 2 2 222 2 2 3 33 15 3 15 3 3 5 5 2 2 11 12 2 2 2 2 2 22 2 2 2 2 2 2 2 2 2 3 3 3 4 4 MOST REMOTE POINT MA X T R A V E L D I S T A N C E F R O M MO S T R E M O T E P O I N T 3 5 ' - 6 " MAX TRAVEL DISTANCE FROM MOST REMOTE POINT 68'-3"13 1 66 6 MOST REMOTE POINT 7 7 LOAD FACTOR: OCC LOAD: 39 SF 8 STANDING SPACE 5 SEATING AREA (BOOTH) LOAD FACTOR: OCC LOAD: 49 SF 4 SEATING AREA 15 LOAD FACTOR: 1 PER 24" 22'-0" LF OCC LOAD: 11 MOST REMOTE POINT TOTAL 12 TOTAL ACCESSIBLE SEATS ( ≥ 5% ) 1 TABLE TOPS AT BANQUETTE 4 8 SEATS 2 TABLE TOP, ROUND 2 4 SEATS 2 DESCRIPTION NUMBER OF ITEMS SEATS PER ITEM INDOOR SEATING CALCULATIONS **RETAIL ESTABLISHMENT SERVES WATER UPON REQUEST. *IN EACH BATHROOM OR TOILET ROOM, URINALS SHALL NOT BE SUBSTITUTED FOR MORE THAN 67% OF THE REQUIRED WATER CLOSETS IN ASSEMBLY OCCUPANCIES. PROVIDED 2 M 2 F 2 M 2 F REQUIRED 1 M 1 F 1 M 1 F 1:1-50 ( MALE ) / 1:1-25 ( FEMALE ) 1:1-150 ( MALE & FEMALE )FIXTURES WATER CLOSETS LAVATORY 19 OCC. 20 OCC. 39 OCC.OCCUPANCY MALE FEMALE TOTAL TABLE 422.1 (2022 CPC) / OCCUPANT LOAD CALCULATED PER 1004.5 2022 CBC PLUMBING FIXTURE CALCULATIONS MAXIMUM. TRAVEL DISTANCE PROVIDED = 68' - 3" MAXIMUM. ALLOWABLE TRAVEL DISTANCE = 100' - 0" NUMBER OF EXITS PROVIDED = 2 NUMBER OF EXITS REQUIRED = 1 EXITS = 72 IN. PRIMARY ENTRY, 36 IN. WORKROOM EXIT WIDTH PROVIDED = 108 IN. EXIT WIDTH REQUIRED - 39 OCC. x 0.2 = 7.2 IN. EGRESS CALCULATIONS N STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 2 2 / 2 0 2 4 1 2 : 1 1 : 4 8 P M C: \ U s e r s \ b s a u n \ H e s t i a A t e l i e r D r o p b o x \ P r o j e c t s \ S t a r bu c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \ T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t G003 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES LIFE SAFETY AND ACCESSIBILITY PLAN 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 OCCUPANCY CALCULATION Name Area LOAD FACTOR OCCUPANT LOAD SEATING AREA 64 SF 15 5 RETAIL 350 SF 60 6 BACKBAR 292 SF 200 2 RESTROOMS / VESTIBULE 123 SF 0 WORKROOM 317 SF 200 2 MANAGER / PARTNER REST AREA 122 SF 150 1 STANDING SPACE 39 SF 5 8 SEATING AREA Not Placed 15 SEATING AREA 49 SF 15 4 GRAND TOTAL 28 1/4" = 1'-0"1EGRESS/OCCUPANCY PLAN (BOOTH)22 ' -0" LF 1 PER 24"11 39 0 A A A A Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments 2301 N Tustin Ave #A8/22/2024 WOMEN INDICATES MINIMUM CLEAR SPACE AT DOOR DOOR STRIKE SWING SIDE OF DOOR BUILDING WALL DOOR / DOOR SWING MINIMUM REQUIRED DOOR CLEARANCE STOREFRONT, INTERIOR OR EXTERIOR DOOR - A LEVEL AND CLEAR FLOOR OR LANDING ON EACH SIDE OF DOOR SHALL BE PROVIDED. THE LEVEL AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60" AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 48" AT DOORS WITH AUTOMATIC CLOSURES AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN THE CLOSED POSITION 1' - 0" 4' - 0 " 1' - 6" CLR. @ INTERIOR DOORS 2' - 0" CLR. @ EXTERIOR DOORS 4' - 0" 5' - 0 " 5' - 0" LEVER HANDLE NOTE: CBC SECTION 11B-703 ANSI A117.1, 703.3.10, 703.4.5 ROOM IDENTIFICATION SIGNAGE SEE 11/- TO B O T T O M O F C H A R A C T E R 60 " M A X . BO T T O M O F B R A I L L E 48 " M I N . - 6 0 " M A X . HEIGHT OF TACTILE SIGNS AND BRAILLE: TYPICAL AT EXITS AND RESTROOMS 34 " M I N . T O 4 4 " M A X . 58 " M I N . T O 6 0 " M A X . A . F . F . MAX. 9" TEXT: 5/8" MIN. - 2" MAX. PARTIAL SIGNAGE SECTION AND MOUNTING SPECIFICATIONS FACE OF TOILET ROOM DOOR CENTER OF SIGNAGE IDENTIFYING SIGNAGE TOILET ROOM IDENTIFYING SIGNAGE DOUBLE STICK MOUNTING FOAM 58 " - 6 0 " A . F . F . 1/4" THICK ACRYLIC PLASTIC- IMAGE AND LETTERS SHALL BE ENGRAVED (MIN. 1/32" DIST.) INTO PLAQUE SURFACE. SYMBOLS AND LETTERS SHALL BE DIFFERENT FROM THE DOOR IN COLOR AND CONTRAST. SUBSURFACE IMAGES SHALL BE CENTERED ON PLAQUE. UNISEX WOMEN MEN 1' - 0" 1' - 0" 1' - 0" LIGHT SWITCH THERMOSTAT SEAT COVER & TISSUE DISPENSER AND / OR NAPKIN DISPOSAL GRAB BAR PROTRUSION 14" MIN. OUTWARD INSULATE HOT WATER & DRAIN PIPES OPERATING DEVICE HEIGHT MIRROR - 40" MAX. TO BOTTOM EDGE OF REFLECING SURFACE SOAP DISPENSER PAPER TOWEL DISPENSER 44 " M A X . 40 " MA X . 33 " - 3 6 " 19 " M A X . 17 " M I N . 1' - 5 " M A X . R I M H E I G H T LAVATORYURINAL WATER CLOSET SIDE WATER CLOSET FRONT MA X . 34 " MI N . 27 " OUTLET OVER COUNTER OUTLET BO T . F I X T . 15 " M I N . T. O . F I X T . 48 " M A X . ELECTRICAL 18" MAX. 17" MIN. MIN. 1' - 0" MIN. 2' - 0" 7"-9" MI N . 1 1 / 2 " HARDWARE / EFFORT CBC 11B-404.2.7 / 11B-404.2.9 TYPE OF HARDWARE: PUSH / PULL HARDWARE MUST BE CENTERED BETWEEN 34" AND 44" A.F.F. MAX. EFFORT FOR INT. / EXT. DOOR - 5 LBS. SMOOTH SURFACE PER CBC SECTION 11B- 404.2.10 10" KICKPLATE OR SMOOTH SURFACE FULL WIDTH OF DOOR THRESHOLDS CBC SECTION 11B-404.2.5 1/2" HIGH MAX. THRESHOLD 1/4" PER FOOT MAX. SLOPE DOOR SIZE CBC SECTION CBC 11B-404.2.3 3'-0" WIDE 6'-8" HEIGHT 32" CLEAR WIDTH 90 DEGREE DOOR OPENING EXTERIORINTERIOR CL 1/ 2 " M A X . 10 " M I N . 34" TO 44" A.F.F. MAX. 0'-0" FIN. FLR. LETTERS - 5/8" MIN. - 2" MAX. - 1/32" RAISED TEXT AND ASSOCIATED BRAILLE SHALL READ AS INDICATED IN THE DRAWING AND PER CBC SECTTION 1011 & ANSI 117.1, 703.3.10, 703.4.5 EXIT 3" M I N . . .. .. ... . . . ... BRAILLE PER CBC 11B-703.3.2 5' - 0 " ( 6 0 " ) M A X . FIN. FLR. 4' - 0 " ( 4 8 " ) M I N . EXIT EXIT... .. ... ... .. ... THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY DISABLED PERSONS. THE SYMBOL SPECIFIED ABOVE SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN FEDERAL STANDARD 595B. 6" 6" 1/8 " STEEL BACKING PLATE - WELD TO (3) STUDS MINIMUM METAL SPACER INTERIOR FINISH - SEE ELARGED TOILET PLAN AND FINISH SCHEDULE 1 1/2 " O.D. GRAB BAR (N . T . S . ) 33 " M I N . T O 3 6 " M A X FIN. FLR. 1 1/2" TOP OF GRIPPING SURFACE CLEAR KNEE SPACE WALL MOUNTED LAVATORY 19 " MAX 17" MIN. 34 " M A X . 29 " M I N . 9" M I N . 6" MAX. 8" MIN. KNEE CLEARANCE OF R E F L E C T I V E S U R F A C E 40 " M A X . T O B O T T O M INSULATION AROUND PIPE 27 " M I N . 11" MIN. (30" MIN.) 2' - 6" (4 8 " M I N . ) 4' - 0 " (1 9 " M I N . ) 1' - 7 " TABLE TOP @ +34" A.F.F. (28" MIN. - 34" MAX.) 30" X 48" CLEAR FLOOR SPACE 2' - 3 " M I N 6' - 8 " M I N 4" MAX 1' - 3 " M I N 4' - 0 " M A X 4' - 0 " M A X 1' - 8" MAX 3' - 8 " M A X >20"-25" MAX 3' - 1 0 " M A X 2' - 1 0 " M A X >10"-24" MAX 2' - 1 0 " M A X 0' - 10" MAX 4' - 0 " M A X 1' - 3 " M I N 4' - 0 " M A X 0' - 10" MAX 42"MINIMUM 33 " - 3 6 " M A X . 24" MIN. 33 " - 3 6 " M A X . 36" MIN. 12" MAX. TO TOP OF GRAB BAR 17" MIN. / 18" MAX. TO CENTERLINE OF WATER CLOSET REINFORCEMENT BACKING - TYP. - SEE DETAIL 5 / SHEET G-003 GRAB BAR LENGTH PROVIDE 1-1/2" MIN. BETWEEN TOP OF TANK AND BOTTOM OF GRAB BAR 12" MIN . 24" MIN . 1/4" = 1'-0"6MINIMUM DOOR CLEARANCE 1/2" = 1'-0"3ACCESSIBLE RESTROOM SIGNAGE1" = 1'-0"11RESTROOM IDENTIFYING SIGNS 1/4" = 1'-0"4ACCESSIBLITY FOR ACCESSORIES - STANDARD MOUNTING HEIGHTS 12" = 1'-0"7ENTRANCE DOOR ADA DETAIL 12" = 1'-0"1TACTILE EXIT SIGN 3" = 1'-0"2INTERNATIONAL ACCESSIBILITY SYMBOL 6" = 1'-0"5TOILET GRAB BAR13/4" = 1'-0"9KNEE SPACE AT LAVATORY 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 6 : 3 2 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t G004 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ACCESSIBILITY DETAILS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 3/4" = 1'-0"13KNEE SPACE AT TABLE1/2" = 1'-0"17UNOBSTRUCTED PATH OF TRAVEL 3/4" = 1'-0"18UNOBSTRUCTED FORWARD REACH 3/4" = 1'-0"15OBSTRUCTED HIGH FORWARD REACH 3/4" = 1'-0"16OBSTRUCTED SIDE REACH 3/4" = 1'-0"14UNOBSTRUCTED SIDE REACH 12" = 1'-0"8GRAB BAR REINFORCEMENT Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 6 : 3 3 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t G004A 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ACCESSIBILITY NOTES 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 AUTOMATIC DOORS 1. AUTOMATIC DOORS SHALL COMPLY WITH C.B.C.SECTION 11B-404.3 2. FULL-POWERED AUTOMATIC DOORS SHALL COMPLY WITH ANSI/BHMA A156.10. LOW -ENERGY AND POWER ASSISTED DOORS SHALL COMPLY WITH ANSI/BHMA A156.19 3. THE MIMINUM CLEAR WIDTH FOR AUTOMATIC DOOR SYSTEMS IN A DOORWAY SHALL PROVIDE A CLEAR UNOBSTRUCTED OPENING OF 32 INCHES MINIMUM WITH ONE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. 4. CLEARANCES AT POWER ASSISTED DOORS AND AUTOMATIC DOORS SERVING AN ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH C.B.C. 11B-404.2.4 5. THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS WITH AUTOMATIC DOORS SHALL COMPLY WITH CBC 11B-404.2.5 6. MANUALLY OPERATED ACTUATOR CONTROLS FOR AUTOMATIC DOORS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM. 7. THE CLEAR FLOOR SPACE ADJACENT TO THE CONTROL SHALL BE LOCATED BEYOND THE ARC OF THE DOOR SWING AND SHALL COMPLY WITH C.B.C. 11B-305 8. AUTOMATIC DOOR OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR MORE OF THE REACH RANGES SPECIFIED IN C.B.C. 11B-308 9. WHERE DOORS AND GATES WITHOUT STANDBY POWER ARE PART OF A MEANS OF EGRESS, THE CLEAR BREAK OUT OPENING AT SWINGING OR SLIDING DOORS AND GATES SHALL BE 32 INCHES MINIMUM WHEN OPERATED IN EMERGENCY MODE, UNLESS MANUAL SWINGING DOORS AND GATES COMPLY WITH C.B.C 11B-404.2 AND SERVE THE SAME MEANS OF EGRESS. 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 6 : 3 5 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t G004B 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ACCESSIBILITY NOTES 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 A. GENERAL CONTRACTOR TO VERIFY ALL EXISTING ELEVATIONS AND BUILDING CONDITIONS IN FIELD PRIOR TO START OF CONSTRUCTION. B. PROVIDE DETECTABLE WARNING (IF APPLICABLE PER LOCAL CODE) AT TRANSITION FROM SIDEWALK TO DRIVE AISLE. C. ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL HAVE SURFACE SLOPE NOT TO EXCEED 2% IN ALL DIRECTIONS. D. REFER TO ELECTRICAL DRAWINGS FOR SITE RELATED ELECTRICAL WORK. (WHEN APPLICABLE) E. EXISTING SITE FEATURES TO REMAIN, NO CHANGE U.N.O GENERAL NOTES SITE PLAN KEYNOTES 1 NEW GREASE INTERCEPTOR. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION 3 NEW DT DIRECTIONAL EXIT/THANK YOU SIGN. MOUNT TO EXISTING FOOTING 4 NEW DT CLEARANCE BAR. (UNDER SEPARATE PERMIT) 2 NEW DT DIRECTIONAL ARROW SIGN. MOUNT TO EXISTING FOOTING 7 RESTRIPE EXISTING ACCESSIBLE PARKING. REFER TO 7/A002 FOR MORE INFORMATION 8 EXISTING PARKING STALL TO REMAIN. 9 EXISTING MOP (MOBILE-ORDER-PAY) DEDICATED PARKING STALL TO REMAIN 10 EXISTING DIGITAL ORDER SCREEN TO REMAIN. 11 EXISTING TRASH ENCLOSURE TO REMAIN. EXISTING DEDICATED AREA FOR RECYCLING. 19 NEW WAYFINDING PAVEMENT GRAPHICS. 16 RESTRIPE EXISTING FADED ACCESSIBLE PATH CROSSWALK. REFER TO 1/ A002 12 STARBUCKS, AREA OF WORK. 13 EXISTING PATIO AREA TO REMAIN. NO EXTERIOR SEATING IS BEING PROPOSED. 14 EXISTING LANDSCAPED AREA TO REMAIN 15 EXISTING PUBLIC RIGHT OF WAY 18 EXISTING NON-ILLUMINATED BOLLARD TO REMAIN. 17 EXISTING DT 5-PANEL MENU BOARD TO REMAIN. 5 EXISTING ACCESSIBLE PATH OF TRAVEL FROM/TO ACCESSIBLE PARKING 6 EXISTING ACCESSIBLE PATH OF TRAVEL FROM/TO PUBLIC RIGHT OF WAY 20 NEW INTERNATIONAL SYMBOL FOR ACCESSIBLE PARKING -REFER TO 2/A002 21 EXISTING ACCESSIBLE PARKING SIGNAGE TO REMAIN PER DETAIL 5/A002 22 EXISTING DRIVE-THRU LANE TO REMAIN. 23 EXISTING ADJACENT TENANT. (NIC) 24 EXISTING DETECTABLE WARNINGS TO REMAIN. REFER TO 4/A002 25 EXISTING ACCESSIBLE PATH SIGN TO REMAIN. REFER TO DETAIL 6/A002. 26 EXISTING TOWAWAY SIGN TO REMAIN PER DETAIL 8/A002. EXISTING LANDSCAPE AREA LEGEND EXISTING 6" (150MM) CONCRETE CURB ACCESSIBLE UNOBSTRUCTED PATH OF TRAVEL 48" MIN WIDTH (UNLESS NOTED OTHERWISE) WITH SLOPE NOT TO EXCEED 5% IN DIRECTION OF TRAVEL AND CROSS SLOPE NOT TO EXCEED 2% N T U S T I N A V E . E SANTA CLARA AVE. 1 2 3 4 5 6 7 8 Y 23113 S 22544 S 23077 S 23071 Y 23115 S 23077 Y 23117 Y 23117 Y 23117 Y 23117 Y 23117 Y 23117 ADJACENT TENANT (NIS) 1 2 4 2 3 5 5 6 78 8 88 6 9 10 11 12 13 14141414 14 14 14 14 1414 15 15 15 15 15 15 16 17 18 19 19 19 19 19 19 19 19 20 21 22 22 23 24 24 24 25 P 21669 P X21676 26 26 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 6 : 5 6 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t A001 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ARCHITECTURAL SITE PLAN 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 N 3/32" = 1'-0"1ARCHITECTURAL SITE PLAN Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 6' - 8 " A . F . F . +3 6 " W A L L M O U N T E D TEXT SHALL NOT BE LESS THAN 1 INCH IN HEIGHT NOTE: 1. CONTRACTOR SHALL VERIFY THE ADDRESS AND PHONE NUMBER INDICATED ON SIGN PRIOR TO THE PRINTING OF SIGNS. 2. THE ADDRESS AND PHONE NUMBER SHALL BE IMPRINTED ON THE SIGN BY THE SIGN COMPANY. 3. THIS SIGN SHALL BE PLACED AT THE ENTRANCE TO OFF-STREET PARKING FACILITIES. THE NAME, ADDRESS AND PHONE NUMBER SHALL BE IMPRINTED ON THE SIGN BY THE SIGN COMPANY UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT (---ADDRESS---) OR BY TELEPHONING (XXX) XXX-XXXX 17" MIN. 2' - 0" 22 " M I N . 2' - 7 " FINISH SURFACE OR GRADE REFLECTIONIZED PORCELIAN ENAMELED STEEL SIGN WITH BEADED LETTERS OR EQUAL BOLTED TO 2" SQ. BRONZE POWDER COATED POST WITH (2) 3/8" DIA. BOLTS - SIGN TO DISPLAY INTERNATIONAL SYMBOL OF ACCESIBILITY AND HAVE A DIRECTIONAL ARROW INDICATING THE ACCESSIBLE PATH-OF-TRAVEL 10" 1' - 0 " 5' - 0 " N . T . S . 0.90" AT BASE 0.45" AT TOP 0. 2 0 H T . TYPICAL PLAN TYPICAL SECTION A A - NOTE: 1. DETECTABLE WARNING SURFACES SHALL BE YELLOW CONFORMING TO FS 33538 OF FEDERAL STANDARD 595C." (CBC, Sec. 11B-705.1.1.3). MATERIAL SHALL BE INTEGRAL PART OF THE WALKING SURFACE. 2. DETECTABLE WARNING SURFACES SHALL CONTRAST VISUALLY WITH ADJACENT WALKING SURFACES EITHER LIGHT-ON-DARK OR DARK-ON-LIGHT. THE MATERIAL USED TO PROVIDE CONTRAST SHALL BE AN INTEGRAL PART OF THE SURFACE." (CBC, SEC. 11B-705.1.1.3). 3. ONLY APPROVED DSA-AC DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACES SHALL BE INSTALLED AS PROVIDED IN THE CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 24, PART 1, CHAPTER 5, ARTICLE 2, 3 AND 4." (CBC, SEC. 11B-705.3). 2. 3 5 " 2.35" ADDITIONAL SIGN REQUIRED AT VAN ACCESSIBLE SPACES WHITE TEXT ON BLUE REFLECTIVE BACKGROUND 1/4" WIDE BORDER LINE AT ALL SIDES WHITE OCCUPANT ON DARK BLUE BACKGROUND METAL SIGN WITH ROUNDED CORNERS CORNERS 3" HIGH TEXT - 1/2" WIDE STROKE 2" HIGH TEXT - 3/8" WIDE STROKE 1. ALL PARKING SPACE SIGNS, IN CALIFORNIA, CONSTRUCTED ON OR AFTER JULY 1, 2008, SHALL INCLUDE THE VERBAGE "$250 MINIMUM FINE". CALIFORNIA VEHICLE CODE SECTION 22511.8 (AB1511), CBC 11B-502.6.2 2. 70 SQ. INCH MINIMUM ACCESSIBLE SIGN PER CBC 11B-502.6 MATCH CENTER SPECIFICATION FOR SIGNAGE CONSTRUCTION AND MATERIALS 1' - 0" 60 " W A L L M O U N T E D 6' - 8 " M I N . P O L E M O U N T E D 2' - 0 " 60 " W A L L M O U N T E D 6' - 8 " M I N . WH E R E O C C U R S ACCESSIBLE ROUTE CROSSWALK STRIPING. 4" WIDE PAINTED BLUE STRIPES, OVER YELLOW HIGHWAY PAINT (2 COATS) WITH DIAGONAL STRIPING AT 3'-0" O.C. NOTE: ALL SLOPE CONDITIONS SHALL COMPLY WITH ACCESSIBLE ROUTE CRITERIA PER STATE OF CALIFORNIA TITLE 24. 3' - 0 " 5' - 0" WHITE PAINTED BORDER AND SYMBOL OVER BLUE BACKGROUND (COLOR NO. 15090 IN FEDERAL STANDARD 595a) 4" TYP.3' - 0"4" TYP. 3' - 0 " 18 ' - 0 " T O T A L S T A L L L E N G T H 3'-0" O.C. NOTE: REFER TO CIVIL DWGS FOR FURTHER INFORMATION. SLOPE IN STALL & LOADING ZONE NOT TO EXCEED 2% IN ANY DIRECTION NO PARKING SL O P E 1/ 4 " P E R FT . M A X . SLOPE 1/4" PER FT. MAX. INTERNATIONAL SYMBOL OF ACCESSIBILITY-REFER TO 2/A002 4" WIDE STRIPED LOADING ZONE-12" HIGH LETTERS READING "NO-PARKING" SHALL BE PAINTED WITHIN THE LOADING ZONE AREA- PAINT COLOR: WHITE EXISTING CONC. CURB ACCESSIBLE CURB RAMP SEE DETAIL 3/A002 PRE-CAST CONCRETE WHEEL 9' - 0" MIN 9' - 0" 9' - 0" MIN 8' - 0" VAN ACC. 0"C.F. 6"C.F. 0"C.F. 6"C.F. 2% 2% 2% 8.3% 8.3% CROSS SLOPE OF LANDING AREAS DO NOT EXCEED 2% IN ANY DIRECTION NOTE: SURFACE WILL REQUIRE 36" SECTION OF TRUNCATED DOMES IF FLAT TRAVEL SURFACE ADJOINS VEHICULAR TRAFFIC WAY 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 6 : 5 7 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t A002 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ARCHITECTURAL SITE ACCESSIBILITY DETAILS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 Revision Schedule Rev Date By Description 1" = 1'-0"8SITE ACCESSIBILITY SIGNAGE 1" = 1'-0"6ACCESSIBLE PATH SIGN 3" = 1'-0"4TRUNCATED DOMES 3/4" = 1'-0"5ACCESSIBLE PARKING SIGN 1/4" = 1'-0"1H.C. ACCESS ROUTE 3/4" = 1'-0"2ACCESSIBLE SYMBOL NOT USEDNOT USEDNOT USED NOT USEDNOT USEDNOT USED NOT USEDNOT USEDNOT USED NOT USEDNOT USEDNOT USED 1/8" = 1'-0"7VAN ACCESSIBLE PARKING 1/8" = 1'-0"3EXISTING CURB RAMP DETAIL STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 KEYNOTES GENERAL NOTES A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. B. GENERAL CONTRACTOR TO PROVIDE FIRE TREATED WOOD STUD BLOCKING, OR EQUIVALENT TO SUPPORT ANY WALL ATTACHMENT AND/OR SIGNAGE. C. IF EXISTING EXTERIOR ENTRANCE THRESHOLD EXCEEDS MINIMUM BARRIER FREE PROVISION OF THE CODE, REMOVE AND REPLACE WITH ACCESSIBLE THRESHOLD. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES AT ACCESSIBLE DOORWAYS TO BE BEVELED WITH A SLOPE NO GREATER THAN 1:12. D. ALL DIMENSIONS ARE TO FACE OF STUD UNLESS SHOWN OR NOTED OTHERWISE. E. GENERAL CONTRACTOR TO PROVIDE WATER RESISTANT TYPE 'X' GYP. BD. AT RESTROOM AND BACKBAR WALLS (ALL WET WALLS). F. ALL DOORS SHALL BE 32” (815MM) MINIMUM CLEAR OPENING WHEN OPENED TO 90 DEGREE POSITION UNLESS OTHERWISE NOTED. G. SEE SHEET A601 OR I601 FOR EXTERIOR DOOR AND WINDOW SCHEDULES. H. STARBUCKS VENDOR TO PROVIDE DOOR HARDWARE COMPONENTS AND GC TO INSTALL. I. VERIFY ALL EXISTING DOORS, HARDWARE AND FRAMES MEET STARBUCKS AND/OR CODE REQUIREMENTS. J. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM THE CITY. K. SEE STRUCTURAL FOR KNEE WALL BRACING IF APPLICABLE. L. SEE SHEET A501 FOR BUILDING DETAILS IF APPLICABLE. M. REFER TO SHEET I104 FOR FLOOR FINISHES. N. PATCH AND REPAIR WALLS AS NECESSARY TO PROVIDE A FINISH READY SURFACE. 3 G.C. TO PROVIDE AND INSTALL 6" CONCRETE CURB AT SAFE -CURB NOT TO EXCEED FOOTPRINT OF SAFE. 1 PROVIDE ADEQUATE REINFORCEMENT AND / OR BLOCKING AS REQUIRED TO SUPPORT WALL ATTACHMENTS -REFER TO WALL BLOCKING KEY. 6 EXISTING ELECTRICAL PANELS TO REMAIN. 7 DIMENSION CONTROL DATUM POINT. 11 NEW RESTROOM DOOR. FINISH PER ELEVATIONS 9 ELECTRICAL PANEL LOCATIONS. MAINTAIN MINIMUM CLEARANCE AS REQUIRED BY CODE. 8 OUTLINE OF BAR PER CASEWORK MANUFACTURER. 10 ALIGN FACE OF FINISHED WALL. 12 NEW TRAFFIC SWINGING DOOR. NO LATCH OR LOCK PROVIDED 13 EXISTING ENTRY/EXIT DOOR TO REMAIN. 14 NEW DRIVE-THRU WINDOW. REFER TO SHEET I602 FOR MORE INFORMATION. 15 EXISTING EXIT ONLY DOOR TO REMAIN. 2 G.C. TO PROVIDE AND INSTALL 6" CONCRETE CURB AT FOOD CASE - CURB NOT TO EXCEED FOOTPRINT OF CASE. 4 G.C. TO PROVIDE AND INSTALL 10" CONCRETE CURB AT MOP SINK RO SYSTEM. 5 EXISTING STOREFRONT TO REMAIN. GENERAL LEGEND NEW FULL HEIGHT WALL EXISTING WALL WALL BLOCKING CALL-OUT - X WALL TYPE TAG WALL BLOCKING KEY SYMBOL ITEM 128 LBS (58 KG) WEIGHT 36" TO 40" HEIGHT A.F.F. 30" (760MM) BEHIND SINK APPROX. WIDTH SHELVES ABOVE COMPARTMENT SINK 200 LBS (91 KG)48" TO 76" 96" (2440MM) CENTERED ABOVE COMPARTMENT SINK SHELVES AT MANAGER'S DESK 300 LBS (136 KG)32" TO 96" 48" (1220MM) 3/4 (19MM) ACX PLYWOOD, CENTERED ON SHELVES DATA RACK 300 LBS (136 KG)44" TO 96" BLOCKING PER DETAIL 1/I502B 30" TO 36"60" (1525MM) AROUND WATER CLOSET 200 LBS (91 KG) COMMERCIAL INSTALLATION REQUIRES CONCEALED ARM CARRIER. REFER TO MFR'S SPECIFICATION. 200 LBS (91 KG) COORDINATE LOCATION AND EXTENT WITH PENTAIR TBD BY VENDOR WORKROOM HAND SINK PASTRY COOLING RACK RESTROOM GRAB BARS RESTROOM HAND SINK REFRESHER RACKS UPPER CBE CABINETRY WATER FILTRATION SYSTEM A B C D E F G H I J K L M BLOCKING PER DETAIL 1/I504BDIGITAL MENU BOARDSN UPPER PARTNER REST CABINETRY ORDER STATUS BOARD 128 LBS (58 KG) BLOCKING PER DETAIL 1/I502B200 LBS (91 KG) 200 LBS (91 KG) 28" (710MM) 3/4 (19MM) ACX PLYWOOD, CENTERED ON RACK 66" TO 120"BLOCKING PER CASEWORK SPECIFICATIONS 100 LBS BLOCKING PER DETAIL 13/I504B GC TO PROVIDE BLOCKING PER MANUFACTURER'S WRITTEN REQUIREMENTS EMPLOYEE'S LOCKERS 300 LBS (136 KG) TBD BY VENDOR 45" TO 63 1/2"1' - 1 5/8" (343MM) - PER SHELF BLOCKING SPECIFICATION TO BE PROVIDED BY VENDORICE DIVERTERO P MERCHANDISE DISPLAY BLOCKING PER DETAIL 3/I502C 1 NEW FULL HEIGHT WALL 3 5/8" X 20 GA. METAL STUDS @16" O.C. WITH 5/8" TYPE "X" GYP. BD. ON BOTH SIDES TO 6" ABOVE CEILING - USE WATER RESISTANT GYP. BD. ON WET WALLS - DRYWALL SCREWS @ 12" O.C. 9,13 SEE WALL STUD TABLE SHEET I501 WALL TYPES I501 NEW FURRED FULL HEIGHT WALL 3 5/8" X 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. ON ONE SIDE TO 6" ABOVE CEILING - USE WATER RESISTANT GYP. BD. ON ALL WET WALLS - DRYWALL SCREWS @ 12" O.C. 3 FINISH MAY OCCUR- SEE WALL FINISH PLAN & INTERIOR ELEVATIONS - TYP. NEW PLUMBING WALL 6" X 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. ON BOTH SIDES TO 6" ABOVE CEILING - USE WATER RESISTANT GYP. BD. ON ALL WET WALLS - DRYWALL SCREWS @ 12" O.C. 2 9,13 I501 9,13 I501 NEW FURRED PLUMBING WALL 6" X 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. ON ONE SIDE TO 6" ABOVE CEILING - USE WATER RESISTANT GYP. BD. ON ALL WET WALLS - DRYWALL SCREWS @ 12" O.C. NEW FURRED FULL HEIGHT WALL 3 5/8" X 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. ON ONE SIDE TO 6" ABOVE CEILING - USE WATER RESISTANT GYP. BD. ON ALL WET WALLS - DRYWALL SCREWS @ 12" O.C. 5 16,19 I501 4 I501 EXISTING WALL EXISTING WALL 16,19 ADJACENT TENANT (NIC) HO L D 10 ' - 7 3 / 4 " 12 ' - 7 1 / 4 " 6' - 7 " 15 ' - 7 " 15 ' - 1 1 / 4 " 3 3/4" 1' - 11 1/4"6' - 8 1/2" 14' - 10 3/4" 16' - 7" 22' - 9 1/2" 35' - 1 3/4" 36' - 2 1/2" 20 ' - 1 1 1 / 2 " 21 ' - 7 1 / 2 " BACKBAR WORKROOM SEATING AREA RETAIL UNISEX CUSTOMER RESTROOM UNISEX PARTNER RESTROOM PARTNER / MANAGER AREA D 10086 08 D 10190 09 D 10190 16 A B B C C D E F G G G G H H I J K L M N O (F.O.F) 11' - 7 1/2" (F.O.F) 5' - 10 1/4" 5' - 6 1/4"3' - 5 1/2" 1' - 10"11' - 5 3/4" 7' - 4 1 / 4 " 2' - 4 " 7' - 6 1 / 4 " 2' - 1 1 " 11 1/4"3' - 0"3' - 6 1/2" CLR (F.O.F) 7' - 5 3/4" CL R ( F . O . F ) 8' - 1 " 3' - 0" 36" MIN CLR F.O.F 3' - 0 3/4"3' - 0 3/4" (F.O.F) 6' - 4 1/4" 36" MIN CLR (F.O.F) 3' - 0 3/4" (F.O.F) 2' - 11 3/4" (F.O.F) 1' - 0 3/4" 1 1 11 1 12 2 2 2 2 2 3 3 3 3 3 3 3 5 3 2 4 3 5 1 1 1 1 1 23 4 5 5 6 7 7 8 8 8 8 9 ALIGN 10 ALIGN 10 11 11 12 13 14 15WX21987 P 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 6 : 5 7 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t A101 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES BUILDING FLOOR PLAN 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 N 1/4" = 1'-0"2FLOOR PLAN Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 A. ALL STUB-UP DIMENSIONS ARE RELATIVE TO FINISHED WALL LOCATIONS (SHOWN AS OUTLINES ON THIS PLAN). REFER TO FLOOR PLAN FOR WALL PLACEMENT. B. FLOOR SINK: REFER TO CUT SHEETS FOR COMPONENT SPECIFICATIONS AND CUTOUT REQUIREMENTS. C. WASTE LINE PENETRATIONS: REFER TO PLUMBING PLANS FOR INDIVIDUAL LINE LOCATIONS. D. STUB-UP PENETRATIONS: REFER TO ELECTRICAL AND PLUMBING PLANS FOR INDIVIDUAL STUB-UP LOCATIONS. E. TOILET FLOOR PENETRATION: REFER TO CUT SHEETS FOR STUB-UP LOCATION RELATIVE TO FINISHED WALL (IF APPLICABLE). F. PENETRATION TO BE LOCATED ON CENTERLINE OF WALL OR AS REQUIRED PER CONDITIONS. G. TRENCHING OUTLINE FOR GUIDELINE USE ONLY. GENERAL CONTRACTOR TO COORDINATE WITH SPECIFIC TRADES AND SITE CONDITIONS TO DETERMINE ACTUAL LAYOUT. H. REFER TO SHEET I104 FOR FLOOR FINISHES. KEYNOTES GENERAL NOTES 1 NEW FLOOR SINK -SEE DETAIL 2 / SHEET A102 2 DATUM CONTROL POINT. 3 NEW WATER CLOSET DRAIN. 5 DEMOLISH EXISTING FLOOR SINK (8) 6 ELECTRICAL STUB-UP LOCATION. SEE ELECTRICAL SHEETS. 7 PLUMBING STUB-UP LOCATION. SEE PLUMBING SHEETS 9 NEW MOP SINK DRAIN. 8 ROUTE SANITIZER DRAIN TO THE NEAREST SANITARY FLOOR SINK. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION 4 NEW FLOOR DRAIN CENTERED WITHIN RESTROOM 10 PROVIDE POWER AT NEW BANGUETTE SEATING. 11 PROVIDE POWER FOR DOOR ACTUATOR PUSH PLATE BOLLARD. LEGEND EXISTING WALL DATUM POINT FLOOR DRAIN FLOOR SINK STUB-UP FLOOR SINK HALF GRATE FLUSH WITH FLOOR FINISH GRAVEL BACKFILL NO-HUB CONNECTION 3" TAIL PIECE CONC INFILL AND TRENCH FOR BELOW GRADE UTILITIES STAINLESS STEEL FLOOR SINK W/CLAMPING FEATURE 1 EQ EQ 3" EQ EQ 1' - 9" DIMENSION DATUM POINT ALL CONDUIT STUB-UPS TO BE WITHIN THIS BOUNDARY 2 3 3 3 3 3 1 / 2 " ESPRESSO BAR DIEWALL 1 3/4" LAN CONDUIT 2 3/4" LAN CONDUIT TO MANAGER'S WORKSTATION 3 3/4" ISOLATED GROUND POWER CONDUIT ESPRESSO BAR ELECTRICAL STUB-UP KEY NOTE: SEE SHEET A102 - BUILDING FLOOR PENETRATION PLAN FOR FINAL DIMENSIONED LOCATION. DIMENSION DATUM POINT ALL CONDUIT STUB-UPS TO BE WITHIN THIS BOUNDARY 1 3/4" POWER CONDUIT TO ELECTRICAL PANEL 2 1/2" PHONE TO MANAGER'S DESK 3 1/2" DATA CONDUIT TO MANAGER'S DESK POS ELECTRICAL STUB-UP KEY 4 1/2" SECURITY TO MANAGER'S DESK 5 3/4" LAN CONDUIT TO POS/SAFE 6 3/4" POWER CONDUIT FOR PASTRY CASE POS DIEWALL EQ EQ 3" EQ EQ 1' - 6" 7"1 2 5 634 NOTE: SEE SHEET A102 - BUILDING FLOOR PENETRATION PLAN FOR FINAL DIMENSIONED LOCATION. EQ EQ 7" EQ EQ 3" DIMENSION DATUM POINT ALL CONDUIT STUB-UPS TO BE WITHIN THIS BOUNDARY 1 CWF STUB-UP 2 CW STUB-UP ESPRESSO BAR PLUMBING STUB-UP KEY 1 2 POS DIEWALL NOTE: SEE SHEET A102 - BUILDING FLOOR PENETRATION PLAN FOR FINAL DIMENSIONED LOCATION. 3 3 / 4 " 2" CLR (N) TRENCH(E) SLAB (E) SLAB 2 1 1 1 #4 EPOXY DOWEL A8 18" O.C. W/9" EMBEDMENT. DOWELS MAY BE STAGGARD ON EACH SIDE OF TRENCG NOT TO EXCEED 18" O.C. ON EACH SIDE. USE SIMPSON SET-XP EPOXY 2 COUNTINIOUS #4 @ 18" O.C (1) #4 MIN. AT TRENCHES 24" OR LESS IN WIDTH ADJACENT TENANT (NIC) BACKBAR RETAIL SEATING AREA WORKROOM PARTNER / MANAGER AREA UNISEX PARTNER RESTROOM UNISEX CUSTOMER RESTROOM 10 5 5 5 5 5 5 5 5 1 P X10726 P X10726 1 P X10726 (3) 1 1 1 1 1 2' - 1 0 3 / 4 " 17 ' - 1 1 " 6' - 3" 6' - 1"12' - 2 3/4" 1 10' - 8 3/4" 11' - 10" 16' - 0 1/2" 2' - 6 1 / 4 " 16 ' - 5 " 22 ' - 3 3 / 4 " 1' - 2 " 9 1' - 1 1/2" 1' - 6 " 1' - 1 3/4" 1' - 6 " 3 3 4 4 8 2 2 A102 5 A102 4 A102 6 7 6 6 13 ' - 2 1 / 2 " 1' - 0" (4) 7' - 0"19' - 10 3/4" 24 5 3 / 4 " 24 2 1 / 2 " 8' - 3 1/4"3' - 10" 20' - 6 3/4" P 10594 P 10594 11 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 6 : 5 9 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t A102 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES BUILDING FLOOR PENETRATION PLAN 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 3" = 1'-0"2ECO-GRIP CLAMPING FLOOR SINK DETAIL G.C. RESPONSIBLE TO VERIFY EXISTING SLAB CONDITIONS PRIOR TO ANY SAWCUT OR TRENCH WORK. ALL DIMENSIONS ARE TO FINISH FACE OF WALLS AND/OR CENTER OF FLOOR SINK AND ELECTRICAL STUB-OUTS G.C. TO X-RAY (E) FLOOR SLAB WHEN PROJECT IS NOT SLAB ON GRADE. G.C. TO COORDINATE ANY CONFLICT W/ STARBUCKS C.M., ARCHITECT, AND ENGINEERS. 1 1/2" = 1'-0"4ELECTRICAL STUB-UPS AT ESPRESSO BAR1 1/2" = 1'-0"5ELECTRICAL STUB-UPS AT POS1 1/2" = 1'-0"6PLUMBING STUB-UPS AT ESPRESSO BAR 1 1/2" = 1'-0"3CONCRETE POUR BACK DETAIL N 1/4" = 1'-0"1FLOOR PENETRATION PLAN Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 EXISTING LANDSCAPE AREA LEGEND EXISTING 6" (150MM) CONCRETE CURB ACCESSIBLE UNOBSTRUCTED PATH OF TRAVEL 48" MIN WIDTH (UNLESS NOTED OTHERWISE) WITH SLOPE NOT TO EXCEED 5% IN DIRECTION OF TRAVEL AND CROSS SLOPE NOT TO EXCEED 2% N T U S T I N A V E . E SANTA CLARA AVE. 1 2 3 4 5 6 7 8 ADJACENT TENANT (NIS) 1 2 2 4 3 5 5 6 6 15 15 15 15 15 78 8 88 9 10 17 18 11 12 13 14141414 14 14 14 14 1414 16 19 19 19 19 19 19 19 19 21 20 22 22 23 24 24 24 25 GENERAL NOTES A. GENERAL CONTRACTOR TO VERIFY ALL EXISTING ELEVATIONS AND BUILDING CONDITIONS IN FIELD PRIOR TO START OF CONSTRUCTION. B. ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL HAVE SURFACE SLOPE NOT TO EXCEED 2% IN ALL DIRECTIONS. C. REFER TO ELECTRICAL DRAWINGS FOR SITE RELATED ELECTRICAL WORK. SITE PLAN KEYNOTES 1 EXISTING GREASE INTERCEPTOR TO REMAIN. NIS 3 DEMO EXISTING DT DIRECTIONAL EXIT/THANK YOU SIGN. KEEP EXISTING FOOTING TO MOUNT NEW SIGN TO IT. 4 DEMO EXISTING DT CLEARANCE BAR. KEEP EXISTING FOOTING TO MOUNT NEW SIGN TO IT. 2 DEMO EXISTING DT DIRECTIONAL ARROW SIGN. KEEP EXISTING FOOTING TO MOUNT NEW SIGN TO IT. 7 RE-STRIPE EXISTING ACCESSIBLE PARKING. 8 EXISTING PARKING STALL TO REMAIN. 9 EXISTING MOP (MOBILE-ORDER-PAY) DEDICATED PARKING STALL TO REMAIN 10 EXISTING DIGITAL ORDER SCREEN TO REMAIN. 11 EXISTING TRASH ENCLOSURE TO REMAIN. EXISTING DEDICATED AREA FOR RECYCLING. 19 DEMO EXISTING WAYFINDING PAVEMENT GRAPHICS. 16 RE-STRIPE EXISTING FADED ACCESSIBLE PATH CROSSWALK. 12 STARBUCKS, AREA OF WORK. 13 EXISTING PATIO AREA TO REMAIN. 14 EXISTING LANDSCAPED AREA TO REMAIN 15 EXISTING PUBLIC RIGHT OF WAY 18 EXISTING NON-ILLUMINATED BOLLARD TO REMAIN. 17 EXISTING DT 5-PANEL MENU BOARD TO REMAIN. 5 EXISTING ACCESSIBLE PATH OF TRAVEL FROM/TO ACCESSIBLE PARKING 6 EXISTING ACCESSIBLE PATH OF TRAVEL FROM/TO PUBLIC RIGHT OF WAY 20 RE-STRIPE INTERNATIONAL SYMBOL FOR ACCESSIBLE PARKING. 21 EXISTING ACCESSIBLE PARKING SIGNAGE TO REMAIN PER DETAIL 5/A002 22 EXISTING DRIVE-THRU LANE TO REMAIN. 23 EXISTING ADJACENT TENANT. (NIC) 24 EXISTING DETECTABLE WARNINGS TO REMAIN. REFER TO 4/A002 25 EXISTING ACCESSIBLE PATH SIGN TO REMAIN. 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 6 : 4 3 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t D001 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ARCHITECTURAL DEMO SITE PLAN 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 N Revision Schedule Rev Date By Description 3/32" = 1'-0"1ARCHITECTURAL SITE PLAN STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 A. IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GENERAL CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY. B. GENERAL CONTRACTOR IS RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO DEMOLITION TO REVEAL FULL SCOPE OF WORK. NOTIFY STARBUCKS CONSTRUCTION MANAGER IF EXISTING CONDITIONS DEVIATE FROM CONSTRUCTION DOCUMENTS. C. REMOVE EXISTING INTERIOR WALL FINISH AS SHOWN. PATCH, REPAIR AND PREP. SUBSTRATE TO RECEIVE NEW FINISH. REMOVE WALL COVERINGS ON EXISTING WALLS TO REMAIN THAT FACE AREAS OF DEMOLITION. REMOVAL SHALL INCLUDE ANY RESIDUAL MATERIAL AFTER DEMOLITION, (I.E. PIECES OF WALL COVERING OR BACKING). REMOVAL OF ALL COVERINGS IS TO BE DONE W/O DAMAGING THE EXISTING WALL SURFACE TO REMAIN. ALSO REMOVE WALL DEVICES AND ITEMS MOUNTED TO WALLS. D. REMOVE EXISTING FLOORING AS SHOWN. PATCH, REPAIR AND PREP. SUBSTRATE TO RECEIVE NEW FINISH. REMOVAL OF EXISTING FLOORING INCLUDES, BUT IS NOT LIMITED TO REMOVAL OF EXISTING CERAMIC TILE, CARPET OR VINYL TILE FLOORING AND ASSOCIATED WALL BASE. SUBFLOOR TO BE STRIPPED OF ALL COVERING/FINISH AND CLEANED TO REMOVE EXISTING ADHESIVE, GROUT, MORTAR, DIRT AND COATINGS. FINAL SURFACE TO BE STREAK-FREE WITH NO MACHINE MARKS AND/OR SMOOTH, STABLE AND LEVEL. PROVIDE LEVELING WHERE NECESSARY TO ACCOMMODATE NEW FINISHES. E. DEMOLITION PLANS REPRESENT APPROXIMATE LOCATION OF EXISTING WALLS TO BE DEMOLISHED. FIELD VERIFY TYPE OF CONSTRUCTION AND HEIGHT OF WALLS. PLANS DO NOT NECESSARILY INDICATE ALL DEMO WALLS, COUNTERS, HANDRAILS, WALL PROTECTION, CLOSETS, SINKS ETC. PRIOR TO DEMOLITION, FIELD VERIFY THAT WALLS TO BE REMOVED DO NOT PROVIDE SUPPORT FOR EXISTING BUILDING ELEMENTS AND EXISTING CONSTRUCTION TO REMAIN. NOTIFY STARBUCKS CONSTRUCTION MANAGER IF DEMOLITION WALLS SUPPORT EXISTING BUILDING ELEMENTS. F. DEMOLISH AND REMOVE DOORS, VINYL BASE, CONDUIT, WIRING, DUPLEXES, DATA OUTLETS, CABLES, SHELVING, METAL STUD AND GYPSUM BOARD WALLS, CLOSETS, CABINETS, FILES, COUNTERS, WOOD MOLDING, SHELVES AND ENCLOSURES WHERE APPLICABLE. G. VERIFY WITH STARBUCKS CONSTRUCTION MANAGER ACCESS TO THE DEMOLITION AREA, INGRESS AND EGRESS ROUTES FOR MATERIAL AND EQUIPMENT. H. PROTECT EXISTING FLOORS, WALLS AND CORNERS TO REMAIN ALONG WORK ACCESS ROUTES. I. CONTAIN DUST AND DEBRIS WITHIN THE DEMOLITION AREA. J. THE GENERAL CONTRACTOR SHALL PERFORM WORK IN A MANNER THAT DOES NOT DAMAGE THE EXISTING STRUCTURE. DEMOLITION SHALL NOT COMPROMISE THE STRUCTURAL INTEGRITY OF ANY WALLS, FLOORS, CEILINGS, SUPPORTS, STRUCTURE, ETC. TO REMAIN. K. ALL DEMOLITION MATERIALS AND DEBRIS SHALL BE DISPOSED OF ACCORDING TO FEDERAL, STATE AND LOCAL REGULATIONS. L. AT LOCATIONS WHERE EXISTING WALLS ARE TO BE REMOVED NEAR EXISTING WALLS TO REMAIN, PERFORM DEMOLITION WITHOUT DISTURBING EXISTING ELEMENTS TO REMAIN. WALLS TO REMAIN SHALL BE INTACT AND HAVE A NEAT SURFACE. M. REFER TO "ITEMS TO BE PRESERVED" LIST FOR ITEMS THAT SHALL BE SALVAGED FOR RELOCATION. VERIFY WITH OWNER FOR ON SITE STORAGE LOCATION OF SALVAGED ITEMS. N. DAMAGED FIREPROOFING SHALL BE REPAIRED/ REPLACED TO MATCH EXISTING. O. THE GENERAL CONTRACTOR SHALL DEMOLISH ANY EXISTING ABANDONED VOICE/DATA CABLING AND DEAD OR NON-USE ELECTRICAL BACK TO PANEL. ALL RECEPTACLES NOT REUSED ARE TO BE REMOVED, PATCHED AND PAINTED. P. REMOVAL OF LOW VOLTAGE EQUIPMENT, PERTAINING TO DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED BY THE STARBUCKS CONSTRUCTION MANAGER PRIOR TO REMOVAL. SALVAGED EQUIPMENT SHALL BE STORED IN A CLIMATE CONTROLLED ENVIRONMENT FOR FUTURE INSTALLATION. Q. LABEL ALL ITEMS AND PROPERLY STORE FOR RE-INSTALL. R. REMOVE EXISTING PLUMBING FIXTURES AND HVAC EQUIPMENT AS NECESSARY. CAP LINES AND TERMINATE DUCTS AS NECESSARY FOR THOSE NOT BEING RE- USED. KEYNOTES GENERAL NOTES 15 DEMO EXISTING FRONTLINE AND BACKLINE -COUNTERTOPS AND CABINETS. SALVAGE ALL COUNTERTOP EQUIPMENT AND 1DR UNDERCOUNTER FRIDGES -U.N.O. 3 EXISTING STOREFRONT TO REMAIN. WINDOWS ARE FIXED AND NOT OPERABLE. 7 DEMOLISH EXISTING FLOOR FINISH, ARTWORK AND WALL FINISH AT CAFE AREA 6 DEMOLISHED EXISTING MERCH BASKETS 5 DEMOLISHED EXISTING NON-LOAD BEARING WALL 8 DEMOLISH EXISTING CONDIMENT CART 17 DEMOLISH EXISTING BACKBAR WALL TILE, MENUBOARDS, UPPER CUBBIES, VALANCE AND TASK LIGHTING 9 DEMOLISH EXISTING MERCH BAY 16 DEMOLISH EXISTING FLOOR TILE AND BASE AT BACKBAR AND WORKROOM AREAS 10 DEMOLISH EXISTING FLOOR TILE / BASE AT CAFE AND VESTIBULE AREA. 11 DEMOLISH EXISTING WALK-OFF MAT 12 DEMOLISH EXISTING INTERIOR FURNITURE THROUGHOUT 13 DEMOLISH EXISTING RESTROOMS AND ALL ASSOCIATED FIXTURES. 18 DEMOLISH EXISTING FLOOR SINK BELOW (8) 1 EXISTING ENTRY/EXIT DOOR TO REMAIN. 4 DEMOLISHED EXISTING BACKBAR TRAFFIC DOOR 2 DEMOLISHED EXISTING DRIVE-THRU WINDOW AND SHELF. 14 EXISTING ELECTRICAL PANEL TO REMAIN 19 DEMOLISH EXISTING LIGHTING CONTROL PANEL 20 EXISTING TEMPERATURE SENSOR TO BE RELOCATED. 21 EXISTING HVAC T-STATS TO BE RELOCATED. (3) LEGEND EXISTING ITEM TO REMAIN ITEM TO BE DEMOLISHED NON-LOAD BEARING WALLS TO BE DEMOLISHED EXISTING ITEM TO BE RELOCATED EXISTING ITEMS TO PRESERVE AND RELOCATE A BLENDERS (2) B ESPRESSO MACHINES (2) C SAFE Q WATER FILLING STATION K WARMING OVEN (2) T 2-DR REACH IN FRIDGE (2) S 2-DR REACH IN FREEZER D WARMING U/C FRIDGE (2) P MANAGER'S STATION EQUIPMENT R 1-DR REACH IN FREEZER E 1-DR U/C FRIDGE (5) M DRIVE-THRU POS EQUIPMENT L POS EQUIPMENT, PRINTER, & PHONE H NITRO TAP / NITRO GENERATOR G CUP LABELER (4) F GRINDER V THAW RACK U SANITIZER W R.O. SYSTEM & WATER HEATER X TRASH BIN I NOT USED J CUP CADDY (2) N PASTRY CART O AV DIGITAL PRODUCTION MANAGER Y METRO RACKS (10) Z ICE BIN A1 HAND DRYER (2) B1 DATA RACK C1 LOCKERS (2) CAFE 7 10 BACKBAR 15 16 WORKROOM 16 VESTIBULE 10 UNISEX RESTROOM 1 UNISEX RESTROOM 2 13 13 ADJACENT TENANT (NIC) 1 1 3 3 3 2 3 3 12 17 8 9 6 6 11 18 18 18 18 1818 18 18 4A E E E E E D K K GF H M G GB B L O N CJJ PW U R S T T X V Q Y Y Y Y Y Y Y Y Y Y 5 5 5 5 5 5 5 55 55 5 RETAIL 7 10 14 Z D B1 A1 A1 C1 19 20 20 21 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 6 : 4 8 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t D101 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES DEMOLITION FLOOR PLAN 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 N 1/4" = 1'-0"1DEMOLITION PLAN Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 GENERAL NOTES A. IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GENERAL CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY. B. REMOVE EXTRANEOUS EQUIPMENT AS NECESSARY. C. EXISTING SPRINKLERS TO REMAIN OPERATIONAL DURING CONSTRUCTION. D. DEMOLISH AND REMOVE SUSPENDED ACOUSTIC LAY-IN, SPLINE OR GYPSUM/ PLASTER CEILING INCLUSIVE OF HANGERS AND CARRYING CHANNELS, WIRES, CABLES, CONDUIT, ADHERED CEILING TILES, FLEX CONDUIT, ELECTRICAL BOXES, SMOKE DETECTORS, LIGHT FIXTURES AND WIRING, DUCT WORK, PIPING AND SUPPORT HANGERS. CUT HANGERS FLUSH. SPACES RECEIVING WALL DEMOLITION WILL ALSO HAVE CEILING DEMOLITION UNLESS OTHERWISE NOTED. E. REMOVAL OF LOW VOLTAGE EQUIPMENT, PERTAINING TO DATA/ COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED BY STARBUCKS CONSTRUCTION MANAGER PRIOR TO REMOVAL. SALVAGED EQUIPMENT SHALL BE STORED IN A CLIMATE CONTROLLED ENVIRONMENT FOR FUTURE INSTALLATION. KEYNOTES 8 DEMOLISH EXISTING UPPER SHELF AND ALL ASSOCIATED LIGHTING & MENU BOARDS 1 OPEN TO STRUCTURE ABOVE. 2 REMOVE ALL EXISTING LIGHTING, WIRING, CONTROLS AND FASTENERS BACK TO ELECTRICAL PANEL 3 REMOVE EXISTING SECURITY CAMERAS, LOW VOLTAGE CABLING AND ASSOCIATED CONDUITS. CAMERAS SHALL BE SALVAGED FOR FUTURE REUSE 7 EXISTING RESTROOM EXHAUST FAN DIFFUSER TO BE RELOCATED 9 EXISTING ELECTRICAL PANELS TO REMAIN 4 EXISTING EMERGENCY EXIT LIGHT/SIGN TO REMAIN 5 EXISTING AIR CURTAIN ABOVE TO REMAIN 6 DEMOLISH EXISTING DUCTWORK AT CAFE AREA. PROVIDE NEW DESTRIBUTION PER MECHANICAL DRAWINGS 10 DEMOLISH EXISTING WALL MOUNTED SPEAKER (3) 11 EXISTING OCCUPANCY SENSOR TO BE RELOCATED (4) 12 DEMOLISH EXISTING LIGHTING CONTROL PANEL 13 DEMOLISH EXISTING MOP SIGN. 14 EXISTING HVAC SUPPLY DIFFUSER TO BE RELOCATED. 15 EXISTING HVAC RETURN DIFFUSER TO BE RELOCATED. 16 DEMOLISH EXISTING HVAC SUPPLY DIFFUSER 17 DEMOLISH EXISTING 2X4 ACT AT WORKROOM 18 DEMOLISH EXISTING SOFFIT AT BACKBAR 19 DEMOLISH EXISTING RESTROOM AND VESTIBULE GYP. BD CEILING LEGEND ITEM TO BE DEMOLISHED NON-LOAD BEARING WALL TO BE DEMOLISHED GWB CEILING TO BE DEMOLISHED EXISTING ITEM TO REMAIN 2X4 ACT TO BE DEMOLISHED EXISTING ITEM TO BE RELOCATED ADJACENT TENANT (NIC) RETAIL 2 3 SEATING AREA 32 BACKBAR 2 3 WORKROOM 2 VESTIBULE 2 UNISEX RESTROOM 1 2 UNISEX RESTROOM 2 2 1 1 3 4 5 6 6 8 8 9 11 11 11 11 10 10 10 14 14 14 15 4 13 1414 15 12 16 16 16 16 716 7 16 17 18 19 19 19 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 6 : 5 1 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t D102 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES DEMO REFLECTED CEILING PLAN 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 N 1/4" = 1'-0"1DEMOLITION REFLECTED CEILING PLAN Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 KEYNOTES GENERAL NOTES 1 ACCESSIBLE 30" X 48" CLEAR SPACE FOR WHEELCHAIR 2 EXISTING ELECTRICAL PANEL TO REMAIN 5 CLEAR SPACE AT ELECTRICAL PANELS. 9 WASTE & RECYCLE STATION. SEE INTERIOR FINISH ELEVATIONS. 11 NEW ORDER STATUS BOARD. PROVIDE POWER AND DATA. 12 EXISTING SAFE LOCATED AT NEW POS CABINET. SEE ELECTRICAL FOR ADDITIONAL INFORMATION. 13 HAND SINK W/ INTEGRAL SPLASH GUARD. 14 ACCESSIBLE 60" DIA. CLEAR SPACE FOR WHEELCHAIR 6 INSTALL NEW INTERIOR FURNITURE THROUGHOUT AS SHOWN. 4 RELOCTED EXISTING FIRE EXTINGUSHER -TYPE 2A10BC PER CFC 906 15 PROVIDE POWER FOR NEW AUTOMATIC DOOR ACTUATOR, PUSH PLATE & HARDWARE KEY SWITCH 16 EXISTING & NEW METRO RACKS TOP SHELF NOT TO EXCEED 5'-9" AFF. 17 MANAGERS DESK. SEE MANAGER'S DESK/EQUIPMENT RACK ELECTRICAL DETAIL FOR ADDITIONAL INFORMATION. 18 NEW TRASH BIN, ORDER BY FACILITY IF NECESSARY. A. THE SITE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM UNLESS OTHERWISE NOTED. B. ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION FOUNDATION STANDARDS OR EQUIVALENT. C. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS, EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR ACCUMULATION OF DUST, DIRT AND DEBRIS. D. EACH HAND WASHING SINK WILL HAVE A SINGLE SERVICE TOWEL AND SOAP DISPENSER, AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR PREMIXING FAUCET. E. SEE SHEET I601 FOR SCHEDULES. F. SEE WALL FINISH PLAN FOR LOCATION, TAGGING AND FINISH SCHEDULES OF APPLIED WALL TREATMENT. G. NO VEGETABLE OR FOOD PREPARATION ON THE PREMISES. H. NON-MOVABLE EQUIPMENT ON THE FLOOR SHALL BE MOUNTED ON 6" LEGS, CASTERS OR MANUFACTURER SUPPLIED SKIDS. I. ALL EQUIPMENT, CONSTRUCTION, AND INSTALLATION SHALL MEET ANSI CERTIFICATION. ALL PLUMBING, GAS LINES AND CONDUITS, ETC., ARE TO BE CONCEALED WHERE POSSIBLE. OTHERWISE, THEY MUST BE A MINIMUM OF SIX INCHES OFF THE FLOOR AND NOT RUN ACROSS AISLE SPACE AND TO BE INSTALLED AT LEAST 1/2" AWAY FROM THE WALL TO FACILITATE CLEANING. ALL EQUIPMENT AND BACKSPLASHES ARE TO BE ADEQUATELY SEALED TO THE WALL. DISPLAYS OF UNPACKAGED FOOD ARE TO BE PROTECTED WITH SNEEZE GUARDS. ALL EXPOSED SURFACES OF SHELVING, CABINETS AND UNDERCOUNTERS ARE TO BE SMOOTH AND SEALED. J. G.C. TO CAULK WHERE COUNTERTOPS MEET FOOD CASE (SEAL WITH THE DEPARTMENT OF ENVIRONMENTAL HEALTH APPROVED CAULKING) IF APPLICABLE PER SCOPE. K. CAULK AND SEAL ALL SEAMS BETWEEN SS COUNTERTOPS USING DOW CORNING BRAND '732 MULTI PURPOSE SEALANT'. L. ALL FOOD STORAGE SHALL BE 6" (150mm) A.F.F. M. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETS) SHALL BE SEALED. N. ALL EQUIPMENT AND CABINETRY WILL BE FLUSH MOUNTED TO COUNTERS, WALLS OR FLOORS, OR BE RAISED TO ALLOW FOR CLEANING. O. CONFIRM ALL NECESSARY EQUIPMENT CLEARANCES PER PRODUCT CUT SHEET (E.G. ICE MACHINE). P. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING DESIGN PLAN. FOR DATA DEVICE SCHEDULE, REFER TO THE ELECTRICAL DESIGN PLAN. Q. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM THE LOCAL JURISDICTION. 19 RELOCATED EXISTING WATER HEATER. MAKE: AO SMITH, MODEL: DRE-52 100, SOURCE OF POWER: ELECTRIC, KW/H:18 3 NEW LUTRON LIGHTING CONTROL PANEL ABOVE. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION 21 RELOCATED EXISTING OCCUPANCY SENSOR (4) 7 NEW MERCHANDISE DISPLAY 22 RELOCATED EXISTING TEMPERTURE SENSOR (2) 20 PROVIDE (2) CONVENIENCE OUTLETS FOR PARTNER USE WITH USB-A / USB-C PORTS 10 DO NOT BLOCK FOOD CASE INTAKE/EXHAUST. 8 RELOCATED EXISTING HVAC T-STATS (3) 23 PROVIDE MIN. 6" SST SIDE SPLASH GUARD AT 3-COMP SINK. GUARD TO EXTEND FULL DEPTH OF THE SINK. PROVIDED BY CASEWORK VENDOR 24 PARTNER RECOGNITION BOARD. SEE INTERIOR ELEVATION. 25 PROVIDE CONVENIECE RECEPTACLE AT PARTNER REST AREA I400 1 ADJACENT TENANT (NIC) (ABOVE) 1 1 1 1 1 1 1 F 21456 F 21842 F 21449 (4)F 23062(2) (5) (5) F 21800 F 18468 C 23964 E 23526 E 23182 E 23423 E 10416 P 10995 P 10922 E 10698 P 23355 (ABOVE) X Y Y Y Y Y Y Y Y Y Y V T T R S Q U P W E 22212 E 10416 E 10462 P 14688 P 13588 E 10947 E 10977 E 13578 E 10222 P 13700 P 10447 P 10804 E 13620 E 10267 E 23454 P 10549 P 10152 F 23062 F 21474 (2) F TK0051FTK0050 E 10462 P 10116 P 21352 E 11115 F 10093 E 10099 E 10859 E 10172 P 11871 E 10862 P 10116 E 11115 P 21352 F 10093 P 11871 E 10099 E 10172 E 10859 E 10862 25 7 14 14 1 1 4 BACKBAR RETAIL SEATING AREA WORKROOM PARTNER / MANAGER AREA UNISEX PARTNER RESTROOM UNISEX CUSTOMER RESTROOM 6 10 9 11 12 13 13 16 16 16 16 17 18 20 21 21 21 C 20369 B1 A1 A1 F TK0076 FTK0053 F TK0078 F TK0077 F TK0079 Z C1 19 D 23131D23130 D 23129 3 15 D 23135 1515 F 21788 8 13 23 16 22 22 F X22178 24 25 F 10756 F 10756 Y 19581 34 " M A X . 2' - 1 0 " 10" - 24" MAX 46 " M A X . 3' - 5 " EXISTING ITEMS TO PRESERVE AND RELOCATE A BLENDERS (2) B ESPRESSO MACHINES (2) C SAFE Q WATER FILLING STATION K WARMING OVEN (2) T 2-DR REACH IN FRIDGE (2) S 2-DR REACH IN FREEZER D WARMING U/C FRIDGE (2) P MANAGER'S STATION EQUIPMENT R 1-DR REACH IN FREEZER E 1-DR U/C FRIDGE (5) M DRIVE-THRU POS EQUIPMENT L POS EQUIPMENT, PRINTER, & PHONE H NITRO TAP / NITRO GENERATOR G CUP LABELER (4) F GRINDER V THAW RACK U SANITIZER W R.O. SYSTEM & WATER HEATER X TRASH BIN I NOT USED J CUP CADDY (2) N PASTRY CART O AV DIGITAL PRODUCTION MANAGER Y METRO RACKS (10) Z ICE BIN A1 HAND DRYER (2) B1 DATA RACK C1 LOCKERS (2) STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 8 / 2 0 2 4 2 : 4 0 : 1 9 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I101 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES FF & E PLAN 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 1/4" = 1'-0"1FURNITURE, FIXTURES AND EQUIPMENT PLAN 1" = 1'-0"ATRASH & RECYCLE CART ACCESSIBILITY N Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments A A 2301 N Tustin Ave #A8/22/2024 A. GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION MANAGER IMMEDIATELY IF A DISCREPANCY EXISTS BETWEEN CASEWORK SHOP DRAWINGS, EXITING SITE CONDITIONS, ARCHITECTURAL DRAWINGS OR BUILT FIXTURES. ALL DIMENSIONS SHALL BE FIELD VERIFIED BY GC PRIOR TO SHOP DRAWINGS PRODUCTION. B. STARBUCKS CONSTRUCTION MANAGER TO COORDINATE AND SCHEDULE CASEWORK DELIVERY DATE. GENERAL CONTRACTOR TO CONFIRM CASEWORK DELIVERY DATE WITH CASEWORK MANUFACTURER AT FOUR (4) WEEKS PRIOR AND THEN ONE (1) WEEK PRIOR TO SCHEDULED DATE OF DELIVERY. C. STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK VENDOR TO SUPPLY CASEWORK LISTED IN THE CASEWORK SCHEDULE, UNLESS OTHERWISE NOTED. D. CASEWORK VENDOR TO PROVIDE COMPLETE SHOP DRAWINGS AND INSTALLATION PACKAGE TO GENERAL CONTRACTOR TO FACILITATE PROPER INSTALLATION. E. ALL CASEWORK BOX BASE / TOE KICKS SHALL BE SET AND LEVELED USING 1/4" (6 MM) NON-ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR. F. SEE INTERIOR FINISH ELEVATIONS AND SCHEDULES FOR LOCATION AND TAGGING OF WALL TREATMENTS BY CV AND OTHERS. G. SEE REFLECTED CEILING PLAN FOR CASEWORK SOFFIT LOCATIONS. H. REFERENCE PLUMBING AND ELECTRICAL PLANS FOR PLACEMENT OF ELECTRICAL, DATA AND PLUMBING ON FRONT AND BACKLINE OF BAR. I. PROVIDE ACCENT LIGHTING AT FRONT EDGE OF BAR. SEE INTERIOR ELEVATIONS AND ELECTRICAL FOR ADDITIONAL INFORMATION. J. CASEWORK VENDOR TO ENGINEER PROPER COUNTERTOP SUPPORT AT ESPRESSO BAR AND OTHER WORKSTATIONS PER STARBUCKS MINIMUM PERFORMANCE REQUIREMENTS. K. REFER TO CASEWORK INSTALLATION MANUAL PROVIDED BY CASEWORK VENDOR FOR COMPLETE INSTALLATION INSTRUCTIONS. L. SEE SHEET I-601 FOR SCHEDULES. M. G.C. TO MODIFY CASEWORK PER CASEWORK DETAILS. N. STORAGE RACKS OR SHELVINGS OVER 5'-9" IN HEIGHT SHALL BE MECHANICALLY SECURED. KEYNOTES GENERAL NOTES 1 INSTALL CASEWORK, COUNTERTOPS, SHELVES, CUBBIES, FINISHES, TRIM AND TABLE TOPS THROUGHOUT. REFERENCE FINISH SCHEDULE AND MANUFACTURER'S SPECIFICATIONS FOR ADDITIONAL INFORMATION. 2 ALL COUNTERTOPS UTILIZED FOR CUSTOMER TRANSACTIONS, INCLUDING BAR, CONDIMENT AND SALES COUNTERTOPS SHALL BE INSTALLED AT 2'-10" (860 MM) MAXIMUM A.F.F. 3 VARIABLE WIDTH FILLER CABINET / COUNTERTOP REQUIRED TO FILL GAP (FIELD VERIFY DIMENSION). VENDOR TO COORDINATE EXACT DIMENSION WITH GC PRIOR TO INSTALLATION 4 DIMENSION CONTROL DATUM POINT 5 ALL WOOD EXPOSED TO WET AREAS TO BE FINISHED AND SEALED W/CLEAR SEALANT 6 REFER TO INTERIOR FINISH ELEVATIONS FOR VERTICAL TRIMS. INDICATES STAINLESS STEEL (SST) COUNTERTOP LEGEND INDICATES SOLID SURFACE (SS) COUNTERTOP DATUM POINT 2' - 8 1/4"1' - 3"1' - 3"9"2' - 1 1/2"1' - 3" 2' - 0 " C X23709 PL0027 4 I401A 1 I401 1 BACKBAR RETAIL SEATING AREA WORKROOM PARTNER / MANAGER AREA UNISEX CUSTOMER RESTROOM UNISEX PARTNER RESTROOM ADJACENT TENANT (NIC) C X1007 WD0073 MAD101-V C 20369 1 2 I401 2 I401A 2 3 5 6 6 I502C 11 1/ 4 " 1' - 1 0 " 1/ 4 " 1' - 1 0 " 1/ 4 " 1' - 1 0 " 1/ 4 " 3/4" 1 1/4" 10 3/4" PL0027 C X1002 4 INDICATES HORIZONTAL 1" x 1" METAL TRIM - MT0029 - CHALKBOARD RESIN COATING C X1009 INDICATES FULL HEIGHT WOOD WALL CLADDING - WD0073 + MAD101-V C X1007 INDICATES HORIZONTAL 1/8" x 1/8" METAL CORNER GUARD TRIM - MT0029 - CHALKBOARD RESIN COATING C X1005 INDICATES SOFFIT WALL CLADDING - PL0027PL0027 1/ 2 " 1' - 2 " 1/ 2 " 3' - 4 " 1/2" 5 1/2" 1/2" 4 PL0027 C X0017 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 0 6 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I102 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES CASEWORK PLAN 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 N 1/2" = 1'-0"4SIREN UPPER CASEWORK PLAN 1/4" = 1'-0"1CASEWORK PLAN N Revision Schedule Rev Date By Description 1/2" = 1'-0"2PARTNER UPPER CASEWORK PLAN1/2" = 1'-0"3DT UPPER CASEWORK PLAN NN STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 KEYNOTES GENERAL NOTES A. WHERE ACOUSTICAL CEILING MEETS WALL, PROVIDE ANGLE WALL MOLDING FOR REVEAL. MATCH CEILING GRID COLOR WHEN APPLICABLE. B. LEAVE (10) ADDITIONAL RETAIL CEILING TILES, TO MATCH RETAIL CEILING PAINT COLOR, ABOVE THE WORKROOM CEILING AT MANAGER'S DESK FOR FUTURE USE. C. PROVIDE GROMMET AT ALL CEILING PENETRATIONS FOR FIXTURES OR SUPPORTS. D. HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SHOWN FOR DESIGN INTENT ONLY. REFER TO MECHANICAL DRAWINGS IF APPLICABLE PER SCOPE. E. DIFFUSERS AND RETURNS AT BACKBAR IN ACOUSTICAL CEILING TILE TO BE CENTERED IN TILE, PAINTED TO MATCH ADJACENT FINISHES - TYP.(IF APPLICABLE) F. PAINT ALL HVAC DUCTS, HVAC DIFFUSERS AND LIGHT TRIM RINGS TO MATCH ADJACENT CEILING OR SOFFIT PAINT COLOR - TYPICAL THROUGHOUT RETAIL PORTION OF STORE. G. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. SEE SHEET I601 & I602 FOR SCHEDULES. H. COORDINATE DUCT LOCATION AND DIFFUSER SIZE WITH MECHANICAL DRAWINGS. I. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING. J. ALL PAINTED SURFACES TO RECEIVE MINIMUM ONE COAT OF PRIMER. REFER TO PAINT SCHEDULE FOR SPECIFICATIONS (SHEET I-601 & I-602). K. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O. L. ADJUST FOCUS OF ALL TRACK AND RECESSED DIRECTIONAL LIGHTING TO FULLY ILLUMINATE ALL ARTWORK, MENU BOARDS, AND MERCH BAYS. M. FILL, PATCH, AND REPAIR AREAS OF GYP. BD. CEILING AT BACKBAR AND STORE PERIMETER WHERE EXISTING LIGHTS HAVE BEEN REMOVED DURING DEMOLITION. N. ARMSTRONG CEILING TILES PER STARBUCKS SPECIFICATIONS. CALL TO VERIFY NUMBERS. MATCH COLORS AS INDICATED ON PLAN. CONTACT: PHYLLIS MILLER (800) 442-4212. O. LIGHTING AT WORKROOM AND LIGHTS IDENTIFIED WITH "NL" (NIGHT LIGHT) TO BE ON A 24 HR LOCK-ON CIRCUIT. P. GENERAL CONTRACTOR SHALL PROVIDE DIMMER FOR INCANDESCENT LIGHTING IN SEATING AREA. Q. LIGHTING FIXTURES IN A.C.T. TO BE CENTERED IN CEILING TILE - U.N.O. R. LIGHT FIXTURES TO BE LOCATED AT PRE-DETERMINED LOCATIONS IN CASEWORK. S. LOCATE EMERGENCY / EXIT LIGHTS ABOVE CENTERLINE DOOR OPENINGS U.N.O. EMERGENCY LIGHTS TO BE PROVIDED WITH 90 MINUTE BATTERY BACK- UP POWER SUPPLY. T. ALL LIGHTS ABOVE BACKBAR AREA TO BE SHATTER PROOF. U. GENERAL CONTRACTOR TO ADJUST THE LENGTH OF EACH PENDANT LIGHT CORD PER THE NOTED A.F.F. HEIGHT. V. REFER TO RESTROOM ELEVATIONS (SHEET I-411) FOR MOUNTING HEIGHT OF RESTROOM WALL SCONCE. W. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI- RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN GYPSUM SOFFIT OVER FRONTBAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT. GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS'CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION. X. GENERAL CONTRACTOR TO PROVIDE AND LOCATE SPRINKLERS PER LOCAL CODES. CONTACT STARBUCKS CONSTRUCTION MANAGER IF DESIGN INTENT IS AFFECTED. Y. REFERENCE LOW VOLTAGE PLAN SHEET AND ELECTRICAL DRAWINGS. Z. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI- RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN GWB SOFFIT OVER FRONT BAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT. GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS' CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION. AA. DATA CABLING ABOVE HEAD SHALL BE IN PLENUM WHEN AVAILABLE. BB. DATA CABLING AT EXPOSED CEILING SHALL BE INSTALLED IN METAL CONDUIT OR PER LOCAL CODE REQUIREMENT. 2 NEW PAINTED GYP.BD. CEILING AT RESTROOM 7 NEW CAFE / RETAIL / BACKBAR / WORKROOM / RESTROOM / PARTNER REST LIGHTING 1 NEW PAINTED GYP. BD. CEILING AT BACKBAR 9 NEW OMNI-AA HVAC SUPPLY DIFFUSER. REFER TO MECHANICAL DRAWINGS FOR MORE INFROMATION 8 EXISTING EMERGENCY LIGHT/SIGN TO REMAIN. 4 NEW 2X4 WASHABLE ACT AT WORKROOM. MANUF: ARMSTRONG, MODEL: CLEANROOM VL-870 3 OPEN TO STRUCTURE ABOVE. PAINT BOTTOM OF DECK AND TRUSSES TO MATCH SW7031 14 PLATFORM FOR HEATER AND WATER FILTRATION. LIFT CEILING THIS AREA ONLY TO INSURE ADEQUATE CLEARANCE FOR SERVICING. 13 EXISTING 42" DOOR ACTIVATED AIR CURTAIN TO REMAIN. 6 NEW SUSPENDED SOUND ABATEMENT ZINTRA BAFFLES. TRAVERTINE DARK FINISH PER SCHEDULES 15 NEW PENDANT SPEAKER AT 11' -2' A.F.F., TYP. 16 NEW CEILING RECESSED SPEAKER. 5 NEW PAINTED GYP. BD CELING AT PARTNER/MANAGER AREA 10 NEW 50F HVAC RETURN DIFFUSER. REFER TO MECHANICAL DRAWINGS FOR MORE INFROMATION 11 RELOCATED EXISTING HVAC SUPPLY DIFFUSER. REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION 12 RELOCATED EXISTING HVAC RETURN DIFFUSER. REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION 17 RELOCATED EXISTING RESTROOM EXHAUST FAN DIFFUSER 18 DASHED LINE INDICATES LED LIGHT TAPE HOUSED WITHIN SOFFIT LIGHT COVE 19 DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE UPPER CBE CABINETRY 20 DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE FRONTLINE COUNTERTOP BELOW 21 DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE PARTNER REST UPPER CABINETRY 22 NEW TITUS 4FT SLOT LINEAR DIFFUSER. REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION 23 NEW LUTRON LIGHTING CONTROL PANEL. REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION 24 PROVIDE POWER FOR DIGITAL MENU BOARDS PER DETAIL 4/I504. REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION 25 EXISTING ELECTRICAL PANELS TO REMAIN 26 NEW DT WINDOW WITH AIR CURTAIN WITHIN TRANSOM. PROVIDE POWER PER ELECTRICAL DRAWINGS. 27 GC TO PAINT ALL THE TRUSSES, DUCTWORK, AND SCRIM ABOVE THE BAFFLES THE SAME COLOR AS SOFFIT -SW7031 MEGA GREIGE 28 DASHED LINE INDICATES PREVIOUS LOCATION OF SUPPLY/RETURN HVAC DIFFUSER. 29 DASHED LINE INDICATES PREVIOUS LOCATION OF RESTROOM EXHAUS FAN. LEGEND TRACK LIGHTING ELEVATION DATUM STRIP LIGHTING PENDANT LIGHT EXIT SECURITY LIGHT SUPPLY AIR RETURN AIR TROFFER MUSIC SYSTEM PENDANT SPEAKER RESTROOM WALL SCONCE ADJUSTABLE RECESSED CAN LIGHT - 800LM - FLOOD - WHITE WALL WASH CAN LIGHT - 1000LM - WHITE ADJUSTABLE RECESSED CAN LIGHT - 700LM - WF - WHITE ADJACENT TENANT (NIC) A 22972 A 22970 (3) L 20662 L 21772 L 21772 L 20661 L 21776 L 19409 L 21779 L 21774 L 20748 L 21774 L 20748 L 21774 L 21783 L 21772 BACKBAR RETAIL SEATING AREA WORKROOM PARTNER / MANAGER AREA UNISEX PARTNER RESTROOM UNISEX CUSTOMER RESTROOM (N) 2X4 ACT AT 10' -0" AFF 4 (N) GYP BD CEILING AT 10' -11" AFF SW7031 (SG) 1 BACKBAR (N) GYP BD CEILING AT 9' -6" AFF SW7031 (SG) 1 (N) SOFFIT AT 7'-10 3/4" AFF PL0027 (N) SOFFIT AT 11'-10" AFF SW7031 (ES) (N) HEADER AT 9' -6" AFF FRP FINISH (N) 2X4 ACT ABOVE RO & WH AT 12'-6" AFF (N) GYP BD CEILING AT 9' -0" AFF SW7031 (ES) (N) GYP BD CEILING AT 9' -0" AFF SW7031 (SG) 2 (N) GYP BD CEILING AT 9' -0" AFF SW7031 (SG) 2 (N) GYP BD CEILING AT 10' -11" AFF SW7031 (ES) 1 L 21774 (3) (32) (6) L 21772 (14) L 21772 (4) (6) (2) (2) (2) (2) (N) HEADER AT 7' -0" AFF L 22216 L 22216 L 22220 L 22220 L 22216 (7) L 21776 UPLIGHT:C DOWNLIGHT:C UPLIGHT:C DOWNLIGHT:B + (N) ZINTRA ACOUSTICAL BAFFLES AT 11' -2" AFF A 19493 (4) A 10015 A 10015 3 5 6 7 7 7 7 7 7 7 7 7 7 8 9999 9 9 99 9 10 10 11 1111 11 12 12 13 14 L 19411 L 21779 (3) L 19409 L 21779 L 19409 L 21779 (2) L 19409 L 21779 L 19409 L 21779 F X19620 TYP. 15 16 17 17 18 18 19 20 21 22 2222 2222 22 24 25 23 9 9 26 8 11 16 7' - 0" (N) HEADER SW7031 (ES) FINISH: TRAVERTINE DARK 1 I501A 3 I501A 10 10 28 28 28 28 28 28 28 29 29 27 7' - 0" (N) FRP HEADER MANUF: ARMSTRONG MODEL: CLEANROOM VL-870 MANUF: ARMSTRONG MODEL: CLEANROOM VL-870 STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 5 / 2 0 2 4 1 0 : 2 2 : 1 7 A M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I103 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES REFLECTED CEILING PLAN 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 1/4" = 1'-0"1REFLECTED CEILING PLAN N Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments A A A A A 2301 N Tustin Ave #A8/22/2024 KEYNOTES GENERAL NOTES A. WHERE ACOUSTICAL CEILING MEETS WALL, PROVIDE ANGLE WALL MOLDING FOR REVEAL. MATCH CEILING GRID COLOR WHEN APPLICABLE. B. LEAVE (10) ADDITIONAL RETAIL CEILING TILES, TO MATCH RETAIL CEILING PAINT COLOR, ABOVE THE WORKROOM CEILING AT MANAGER'S DESK FOR FUTURE USE. C. PROVIDE GROMMET AT ALL CEILING PENETRATIONS FOR FIXTURES OR SUPPORTS. D. HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SHOWN FOR DESIGN INTENT ONLY. CONTACT PROJECT MANAGER IF CHANGED. E. DIFFUSERS AND RETURNS AT BACKBAR IN ACOUSTICAL CEILING TILE TO BE CENTERED IN TILE, PAINTED TO MATCH ADJACENT FINISHES - TYP. F. PAINT ALL HVAC DUCTS, HVAC DIFFUSERS, RECESSED SPEAKERS AND LIGHT TRIM RINGS TO MATCH ADJACENT CEILING OR SOFFIT PAINT COLOR - TYPICAL THROUGHOUT RETAIL PORTION OF STORE. G. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. SEE SHEET I-601 & I-602 FOR SCHEDULES. H. COORDINATE DUCT LOCATION AND DIFFUSER SIZE WITH MECHANICAL DRAWINGS. I. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING. J. ALL PAINTED SURFACES TO RECEIVE MINIMUM ONE COAT OF PRIMER. REFER TO PAINT SCHEDULE FOR SPECIFICATIONS (SHEET I-601 & I-602). K. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O. L. ADJUST FOCUS OF ALL TRACK AND RECESSED DIRECTIONAL LIGHTING TO FULLY ILLUMINATE ALL ARTWORK, MENU BOARDS, AND MERCH BAYS. M. FILL, PATCH, AND REPAIR AREAS OF GYP. BD. CEILING AT BACKBAR AND STORE PERIMETER WHERE EXISTING LIGHTS HAVE BEEN REMOVED DURING DEMOLITION. N. ARMSTRONG CEILING TILES PER STARBUCKS SPECIFICATIONS. CALL TO VERIFY NUMBERS. MATCH COLORS AS INDICATED ON PLAN. CONTACT: PHYLLIS MILLER (800) 442-4212. O. LIGHTING AT WORKROOM AND LIGHTS IDENTIFIED WITH "NL" (NIGHT LIGHT) TO BE ON A 24 HR LOCK-ON CIRCUIT. P. GENERAL CONTRACTOR SHALL PROVIDE DIMMER FOR INCANDESCENT LIGHTING IN SEATING AREA. Q. LIGHTING FIXTURES IN A.C.T. TO BE CENTERED IN CEILING TILE - U.N.O. R. LIGHT FIXTURES TO BE LOCATED AT PRE-DETERMINED LOCATIONS IN CASEWORK. S. LOCATE EMERGENCY / EXIT LIGHTS ABOVE CENTERLINE DOOR OPENINGS U.N.O. EMERGENCY LIGHTS TO BE PROVIDED WITH 90 MINUTE BATTERY BACK-UP POWER SUPPLY. T. ALL LIGHTS ABOVE BACKBAR AREA TO BE SHATTER PROOF. U. GENERAL CONTRACTOR TO ADJUST THE LENGTH OF EACH PENDANT LIGHT CORD PER THE NOTED A.F.F. HEIGHT. V. REFER TO RESTROOM ELEVATIONS (SHEET I-411) FOR MOUNTING HEIGHT OF RESTROOM WALL SCONCE. W. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI- RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN GYPSUM SOFFIT OVER FRONTBAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT. GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS'CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION. X. GENERAL CONTRACTOR TO PROVIDE AND LOCATE SPRINKLERS PER LOCAL CODES. CONTACT STARBUCKS CONSTRUCTION MANAGER IF DESIGN INTENT IS AFFECTED. Y. REFERENCE LOW VOLTAGE PLAN SHEET AND ELECTRICAL DRAWINGS. Z. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI- RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN GWB SOFFIT OVER FRONT BAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT. GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS' CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION. AA. DATA CABLING ABOVE HEAD SHALL BE IN PLENUM WHEN AVAILABLE. BB. DATA CABLING AT EXPOSED CEILING SHALL BE INSTALLED IN METAL CONDUIT OR PER LOCAL CODE REQUIREMENT. 1 DIMENSION CONTROL DATUM POINT 2 WORKROOM ACT STARTING POINT. LEGEND TRACK LIGHTING ELEVATION DATUM STRIP LIGHTING PENDANT LIGHT EXIT SECURITY LIGHT SUPPLY AIR RETURN AIR TROFFER MUSIC SYSTEM PENDANT SPEAKER RESTROOM WALL SCONCE ADJUSTABLE RECESSED CAN LIGHT - 800LM - FLOOD - WHITE WALL WASH CAN LIGHT - 1000LM - WHITE ADJUSTABLE RECESSED CAN LIGHT - 700LM - WF - WHITE EQ 3' - 2"EQ EQ EQ EQ 2' - 9 " EQ EQ 3' - 6"3' - 6"EQ EQ 3' - 6 " EQ EQ EQ EQ EQ EQ 2' - 1 0 " EQ 2' - 0"2' - 4"21' - 8"4" 13 ' - 1 0 1 / 4 " 3' - 1 0 " 7' - 1 0 1 / 2 " LI G H T C O V E 4" 2' - 2 3 / 4 " LI G H T C O V E 4" 1' - 0" 2' - 6" 3' - 2 1/2" 1' - 0 " 2' - 0 " 3' - 2 " 3' - 1 " 3' - 1 " 6' - 5"3' - 11"3' - 4"3' - 11"3' - 2"3' - 11" 5' - 9"3' - 11"2' - 5"3' - 11"5' - 8" 3' - 9 " 7' - 7 1 / 4 " 1' - 5 " 2' - 0 " 2' - 0 " 23' - 8" 1' - 1 0 " 1' - 8 " 1' - 8 " 1' - 8 " 2' - 3 1 / 2 " 3' - 2 1/4"3' - 11"2' - 0" 1' - 9"12' - 4" EQ EQ EQ EQ EQ EQ EQ EQ 1' - 1 1/2" 1 2 2' - 7"6' - 10"25' - 8" I103B 1 Sim BACKBAR RETAIL SEATING AREA WORKROOM UNISEX PARTNER RESTROOM PARTNER / MANAGER AREA PARTNER / MANAGER AREA BACKBAR UNISEX CUSTOMER RESTROOM EQ EQ 3' - 8 1/2"1' - 6" EQ EQ EQ EQ EQ 1' - 11"EQ EQ EQ EQ EQ 1' - 9 " EQ EQ 1' - 4 1 / 4 " 10 ' - 7 " 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 1 3 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I103A 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES REFLECTED CEILING DIMENSION PLAN 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 N 3/8" = 1'-0"1REFLECTED CEILING DIMENSION PLAN Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 KEYNOTES GENERAL NOTES A. WHERE ACOUSTICAL CEILING MEETS WALL, PROVIDE ANGLE WALL MOLDING FOR REVEAL. MATCH CEILING GRID COLOR WHEN APPLICABLE. B. LEAVE (10) ADDITIONAL RETAIL CEILING TILES, TO MATCH RETAIL CEILING PAINT COLOR, ABOVE THE WORKROOM CEILING AT MANAGER'S DESK FOR FUTURE USE. C. PROVIDE GROMMET AT ALL CEILING PENETRATIONS FOR FIXTURES OR SUPPORTS. D. HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SHOWN FOR DESIGN INTENT ONLY. CONTACT PROJECT MANAGER IF CHANGED. E. DIFFUSERS AND RETURNS AT BACKBAR IN ACOUSTICAL CEILING TILE TO BE CENTERED IN TILE, PAINTED TO MATCH ADJACENT FINISHES - TYP. F. PAINT ALL HVAC DUCTS, HVAC DIFFUSERS, RECESSED SPEAKERS AND LIGHT TRIM RINGS TO MATCH ADJACENT CEILING OR SOFFIT PAINT COLOR - TYPICAL THROUGHOUT RETAIL PORTION OF STORE. G. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. SEE SHEET I-601 & I-602 FOR SCHEDULES. H. COORDINATE DUCT LOCATION AND DIFFUSER SIZE WITH MECHANICAL DRAWINGS. I. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING. J. ALL PAINTED SURFACES TO RECEIVE MINIMUM ONE COAT OF PRIMER. REFER TO PAINT SCHEDULE FOR SPECIFICATIONS (SHEET I-601 & I-602). K. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O. L. ADJUST FOCUS OF ALL TRACK AND RECESSED DIRECTIONAL LIGHTING TO FULLY ILLUMINATE ALL ARTWORK, MENU BOARDS, AND MERCH BAYS. M. FILL, PATCH, AND REPAIR AREAS OF GYP. BD. CEILING AT BACKBAR AND STORE PERIMETER WHERE EXISTING LIGHTS HAVE BEEN REMOVED DURING DEMOLITION. N. ARMSTRONG CEILING TILES PER STARBUCKS SPECIFICATIONS. CALL TO VERIFY NUMBERS. MATCH COLORS AS INDICATED ON PLAN. CONTACT: PHYLLIS MILLER (800) 442-4212. O. LIGHTING AT WORKROOM AND LIGHTS IDENTIFIED WITH "NL" (NIGHT LIGHT) TO BE ON A 24 HR LOCK-ON CIRCUIT. P. GENERAL CONTRACTOR SHALL PROVIDE DIMMER FOR INCANDESCENT LIGHTING IN SEATING AREA. Q. LIGHTING FIXTURES IN A.C.T. TO BE CENTERED IN CEILING TILE - U.N.O. R. LIGHT FIXTURES TO BE LOCATED AT PRE-DETERMINED LOCATIONS IN CASEWORK. S. LOCATE EMERGENCY / EXIT LIGHTS ABOVE CENTERLINE DOOR OPENINGS U.N.O. EMERGENCY LIGHTS TO BE PROVIDED WITH 90 MINUTE BATTERY BACK-UP POWER SUPPLY. T. ALL LIGHTS ABOVE BACKBAR AREA TO BE SHATTER PROOF. U. GENERAL CONTRACTOR TO ADJUST THE LENGTH OF EACH PENDANT LIGHT CORD PER THE NOTED A.F.F. HEIGHT. V. REFER TO RESTROOM ELEVATIONS (SHEET I-411) FOR MOUNTING HEIGHT OF RESTROOM WALL SCONCE. W. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI- RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN GYPSUM SOFFIT OVER FRONTBAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT. GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS'CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION. X. GENERAL CONTRACTOR TO PROVIDE AND LOCATE SPRINKLERS PER LOCAL CODES. CONTACT STARBUCKS CONSTRUCTION MANAGER IF DESIGN INTENT IS AFFECTED. Y. REFERENCE LOW VOLTAGE PLAN SHEET AND ELECTRICAL DRAWINGS. Z. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI- RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN GWB SOFFIT OVER FRONT BAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT. GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS' CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION. AA. DATA CABLING ABOVE HEAD SHALL BE IN PLENUM WHEN AVAILABLE. BB. DATA CABLING AT EXPOSED CEILING SHALL BE INSTALLED IN METAL CONDUIT OR PER LOCAL CODE REQUIREMENT. 1 DIMENSION CONTROL DATUM POINT 3' - 2 1/2"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"1' - 11"1' - 10"1' - 10" 1' - 6 1/2"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"1' - 6 1/2" 1' - 8"8' - 8 1/2"6' - 8 1/2"3' - 6"3' - 6"3' - 6"7' - 6 1/2" 10 ' - 6 1 / 2 " 8' - 9 3 / 4 " 5' - 6 3 / 4 " 1' - 3 1 / 4 " 1' - 10" 2' - 7" 1' - 7"2' - 0"2' - 0"2' - 0"2' - 0"7' - 11" 2' - 0"2' - 0"2' - 0"7' - 0" 1' - 9 " 2' - 1 0 3 / 4 " 7' - 6 3 / 4 " 2' - 0 " 2' - 0 " 2' - 0 1 / 4 " 8' - 0 3 / 4 " BACKBAR BACKBAR HO L D 2" 3' - 5" 1 1 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 1 4 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I103B 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ENLARGED SOFFIT DIMENSION PLAN 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 1/2" = 1'-0"1ENLARGED SOFFIT REFLECTED CEILING DIMENSION PLAN N Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 KEYNOTES GENERAL NOTES A. ALL TILE TO BE INSTALLED PER TILE COUNCIL OF AMERICA STANDARDS. B. STARBUCKS TO SUPPLY FLOORING AND BASE FOR FRONT AND BACK OF HOUSE AS NOTED IN SCHEDULES. GENERAL CONTRACTOR TO INSTALL. GENERAL CONTRACTOR TO SUPPLY WORKROOM TILE AND BASE AND INSTALL. GENERAL CONTRACTOR TO SUPPLY AND INSTALL MORTAR, ADHESIVE, AND GROUT. GENERAL CONTRACTOR TO INSPECT ALL TILES AND REJECT DAMAGED OR SUBSTANDARD TILES PRIOR TO C. ALL FLOORING AND BASE MATERIAL TO BE INSTALLED ACCORDING TO STARBUCKS SPECIFICATIONS. D. ALIGN TILE TRANSITIONS ON WHOLE TILES WHEREVER POSSIBLE. E. FOR WALK-OFF MAT / CARPET TILE INSTALLATION, REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS. F. FOR ALL FLOOR AND BASE TILE INSTALLATIONS AT CASEWORK, MECHANICALLY SAND AND SCARIFY WOOD SUBSTRATE TO COMPLETELY REMOVE ALL FINISH. TROWEL ONE PRIMER COAT OF MAPEI TYP 1, KER 903 ADHESIVE AND ALLOW TO AIR DRY. G. TILE BASE AND THRESHOLD GROUT JOINTS TO ALIGN WITH TILE FLOOR GROUT JOINTS. H. REMOVAL OF EXCESS GROUT WILL BE DONE WITH WATER. THE USE OF SULFURIC OR MURIATIC ACID IS PROHIBITED. IF THESE ACIDS ARE USED, THE INSTALLER WILL BE REQUIRED TO REMOVE THE ACID AND RESTORE THE GROUT AT THEIR EXPENSE. I. PROVIDE GROUT JOINT OF 3/16" MAXIMUM DEVIATION OF TILE AND GROUT LINE OF 1/4" PER 4'. J. ADD OR REMOVE EXISTING TILE AND BASE AS REQUIRED BY SCOPE OF WORK. K. EXISTING FLOORING AND WALL BASE TO REMAIN - U.N.O. REPLACE TILE DAMAGED BY DEMOLITION OR CONSTRUCTION. L. CORNERS AND EDGES OF TILE TO BE BULLNOSE. NO OUTSIDE GROUT CORNERS OR RAW TILE EDGES ARE ALLOWED. M. ALL WALLS AND CASEWORK OUTLINES / TOE KICK RECEIVE BASE AS NOTED. N. REFER TO INTERIOR ELEVATIONS FOR BACKBAR WALL TILE LOCATION. O. REFER TO SHEET I402 FOR RESTROOM WALL TILE LOCATION. P. REFER TO SHEET I601 & I602 FOR SCHEDULES. Q. FLOOR-WALL JUNCTURES AT BACKBAR WILL HAVE 3/8" RADIUS COVE, MINIMUM 4" HIGH. R. WORKROOM TO BE FINISHED PER LOCAL CODE REQUIREMENTS. S. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH-GLOSS FINISH 1 NEW FLOOR SINK. 2 6" CONCRETE CURB FOR FOOD CASE AND SAFE. 3 TILE START POINT WHERE INDICATED. 4 REFER TO ENLARGED RESTROOM PLAN ON SHEET I402 FOR MORE INFORMATION 5 WALK-OFF MAT AT ENTRY. SEE INTERIOR DETAIL SHEETS FOR TRANSITION. 6 MOP SINK WHERE INDICATED. SEE PLUMBING PLANS FOR MORE INFORMATION. 7 10" CONCRETE CURB AT MOP SINK. FINISH WITH ECOGRIP UP TO 6" ABOVE CURB WITH 3/8" COVE RADIUS. 8 LOCATION OF CASEWORK SST LEG SUPPORT. 9 FLOOR FINISH TRANSITION POINT. BACKBAR RETAIL SEATING AREA WORKROOM PARTNER / MANAGER AREA UNISEX PARTNER RESTROOM UNISEX CUSTOMER RESTROOM ADJACENT TENANT (NIC) 1 1 1 1 1 1 1 12 2 7 6 8 8 T 19289 5 T 20262 T 20262 T 20259 T 20259 T 20259 3 6' - 0" 4' - 0 " T 19795 T 19795 4 4 B 18735 B 18735 B 18735 B X19795 B X19795 B 18735 B 18735 TYP. 9 9 1 I503 2 I503 4 I503 6 I503 8 I503 8 I503 9 I503 TYP. 10 I503 11 I503 14 I503 17 I503 2 I402 T 19288 FLOOR FINISH LEGEND T 20262 T 19795 T 20259 T 19289 B 18735 POLYVINYLE ECOGRIP FLOORING @ WORKROOM & BACKBAR MANUFACTURER: ALLIED ECO-GRIP, INC. COLOR: PEWTER NEW WALK-OFF MAT @ STORE ENTRY MANUFACTURER: IMPACT SPECIALITIES TYPE / MODEL: HELIX Z2 & HELIX Z1 B X19795 POLYVINYL ECOGRIP FLOORING WRAPS UP 6" ON WALLS AND CABINETS WITH 3/8" COVE RADIUS @ WORKROOM AND BACKBAR MANUFACTURER: ALLIED ECO-GRIP, INC. COLOR: PEWTER FLOOR TILE AT CAFE MANUFACTURER: STONEPEAK TYPE / MODEL: FIANDRE - FRENCH CLAY - 24" X 24" COLOR / FINISH: CAFE - MATTE WALL BASE AT CAFE, PARTNER/ MANAGER AREA, AND RESTROOMS MANUFACTURER: DALTILE TYPE / MODEL: PLAZA NOVA - 6" X 12" COLOR: WHITE IMAGE FLOOR TILE AT PARTNER AREA AND RESTROOMS MANUFACTURER: STONEPEAK TYPE / MODEL: FMG - VENICE VILLA - 24" X 24" COLOR / FINISH: IVORY - NATURAL T 19288 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 1 6 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I104 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES FLOOR FINISH PLAN 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 1/4" = 1'-0"1FLOOR FINISH PLAN N Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 KEYNOTES GENERAL NOTES A. GENERAL PAINT NOTES: 1. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. 2. TO LOCATE THE NEAREST SHERWIN WILLIAMS STORE, CALL (800) 321-8194. ORDER PAINT BY STARBUCKS COFFEE COMPANY PROGRAM "COLOR CODE". PAINT FORMULAS FOR "COLOR CODE" AVAILABLE AT (800) 321-8194. FURTHER INFORMATION AVAILABLE THROUGH ED STEIN AT (888) 731-7379. 3. SUBMIT TWO (2) SETS OF 8.5" X 11" BRUSH-OUTS OF ALL PAINT COLORS AND FINISHES TO THE STARBUCKS CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO PAINTING. 4. REFER TO INTERIOR ELEVATIONS FOR COLOR LOCATIONS. 5. ALL WOOD AND METAL SURFACES SHALL BE PAINTED SEMI-GLOSS - U.N.O. 6. WALL RECEIVING VINYL MURAL WALLCOVERING SHALL BE SMOOTH AND PVC PRIMED. MURALS TO BE SEALED. SEALER IS PROVIDED WITH MURAL. B. PROVIDE AND INSTALL FULL-HEIGHT F.R.P. @ MOP SINK ENCLOSURE AND ALL NEW WORKROOM WALLS. C. PAINT COLOR TRANSITIONS ALLOWED AT CORNERS ONLY. D. REFER TO INTERIOR ELEVATIONS FOR GRAPHICS LOCATIONS. E. REFER TO CASEWORK FINISH SCHEDULE ON SHEET I601 FOR FURTHER CASEWORK FINISH INFORMATION. F. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. G. REFER TO INTERIOR ELEVATIONS AND REFLECTED CEILING PLAN FOR PAINT CALL OUTS. H. REFER TO SHEET I-601 FOR WALL TILE INFORMATION. I. COORDINATE WINDOW SHADE LOCATIONS WITH STARBUCKS CONSTRUCTION MANAGER. J. G.C. TO APPLY F.R.P. TO ALL SIDES OF CABINET INTERIOR & WALLS UNDER COUNTER. K. INSTALL FRY REGLET CORNER TRIM PIECES AS NEEDED IN FRONT OF HOUSE WHERE DRYWALL TO DRYWALL CORNERS EXIST WITH NO PROVIDED WAINSCOT PROTECTION. ITEM IS G.C. PROVIDED DURING DRYWALL TAPING PROCESS. TRIM PIECE CAN BE FIELD PAINTED. IF TO BE PAINTED, G.C. TO REQUEST DMCT - 375 WITH CHEM FILM - A PAINTABLE SURFACE APPLIED BY THE SUPPLIER AT NO ADDITIONAL COST. L. REFER TO I402 FOR RESTROOM FINISH INFORMATION. 1 INSTALL NEW FULL HEIGHT F.R.P. AT NEW WORKROOM WALLS 2 INSTALL BACKBAR WALL TILE USING STACKED VERTICAL PATTERN @ EXPOSED WALL SURFACE BETWEEN BASE OF UPPER CUBBIES AND TOP OF BACKSPLASH AND BEHIND WARMING OVENS AND UNDERCOUNTER FRIDGES. 3 INSTALL NEW F.R.P. AT BACK BAR CABINETS BELOW COUNTERTOPS AT HIDDEN AREAS. 4 ENLARGED RESTROOM ELEVATION REFER TO I402 5 REFER TO INTERIOR ELEVATIONS FOR PAINT LOCATION & TYPE 6 PROVIDE SST CORNER GUARD AT WORKROOM. WALL FINISH LEGEND NEW CERAMIC WALL TILE AT BACKBAR, PARTNER REST AREA, AND CUSTOMER RESTROOM MANUFACTURER: UNITED TILE CORP TYPE / MODEL: MOSA - 4" X 12" COLOR: UNBLEACHED WHITE Q 22817 SW7103 INDICATES SHERWIN WILLIAMS SEMI-GLOSS PAINT AT BACKBAR AND RESTROOM, AND EGGSHELL PAINT AT CAFE AND PARTNER / MANAGER AREA COLOR: WHITETAIL INDICATES ARTWORK PER SCHEDULEG 21491 WAINSCOTT WALLCOVERING + 1" X 1" METAL CHAIR RAIL - MD0029 @3' - 1" AFF TYPE / MODEL: TEXTURGLAS - TG21 HERRINGBONE PAINT COLOR: WILLOW TREE Q 11469 INDICATES FRP FINISH AT WORKROOM AND PARTNER RESTROOM COLOR: WHITE INDICATES WALLCOVERING AT CAFE TYPE / MODEL: TEXTURGLAS - TG21 HERRINGBONE PAINT COLOR: LAUREL WOODS Q 17778 G 22043 G 22922 SW7741 Q 17778 SW7749 INDICATES SOFFIT WALL CLADDING - PL0027 INDICATES FULL HEIGHT WOOD WALL CLADDING AT CAFE - WD0073CX1007 WD0073 ADJACENT TENANT (NIC) BACKBAR RETAIL SEATING AREA WORKROOM PARTNER / MANAGER AREA UNISEX PARTNER RESTROOM UNISEX CUSTOMER RESTROOM 1 2 3 5 5 5 5 4 4 I201 3 1 I202 13 I201 15 I203 2 1 4 I203 11 12 I204 1 I204 9 2 10 6 I202 14 13 16 15 I204 34 12 I205 2 3 4 20 I503 16 I503 6 6 6 6 I2033 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 1 7 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I105 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES WALL FINISH PLAN 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 1/4" = 1'-0"1WALL FINISH PLAN N Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON SHEET I601. B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION. C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE INDICATED. D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE: 1) WOODS AND METAL SURFACES SHALL BE SEMI-GLOSS OR EQUAL. 2) ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL. a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL. 3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR EQUAL. E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN ORDERING PAINTS. F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH. G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE SEALED. H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION. I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F. L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING BACK BAR TILE. M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. N. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE - RUN BACKBAR WALL TILE TO UNDERSIDE OF WALL CABINETS - NOT BEHIND CABINETS. O. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING. P. ALL PAINTED SURFACES TO RECEIVE A MINIMUM ONE COAT OF PRIMER. SEE PAINT SCHEDULE FOR SPECIFICATIONS. Q. PAINT SHALL NOT BE APPLIED OVER EXISTING MURALS OR VINYL WALLCOVERING. R. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O. S. SEE I402 ENLARGED RESTROOM PLAN DETAILS FOR ACCESSORY MOUNTING HEIGHTS. T. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. U. CASEWORK, COUNTERTOPS AND WALL MOUNTED FURNISHINGS TO BE ATTACHED TO SUPPORTING MEMBERS PER PRODUCT MANUFACTURER'S SPECIFICATIONS. V. TILE BASE - REFER TO I104 FOR DESIGN ID TAG AND DETAILS. KEYNOTES GENERAL NOTES 1 NEW ARTWORK -REFER TO SCHEDULE "G" ON SHEET I601 2 ALIGN TOP OF 1" X 1" HORIZONTAL METAL TRIM WITH TOP OF STOREFRONT MULLION 3 EXISTING MAIN ENTRY/EXIT DOOR TO BE REMAINED. 4 EXISTING EMERGENCY EXIT LIGHT/SIGN TO BE REMAINED IN PLACE 7 36" DOOR ACTUATOR PUSH PLATE 6 ACCESSIBLE UNISEX RESTROOM SIGNAGE -SEE DETAIL 3/G004 8 DOOR ACTUATOR OPERATOR DEVICE. 9 DOOR ACTUATOR CAUTION SIGN. 10 RESTROOM DOOR. FINISHED PER SCHEDULE 12 NEW RECYCLE STATION 11 NEW ROLLER SHADE. 13 NEW WOOD PANELING -WD0077 MAD101-V 14 DOOR ACTUATOR KEY SWITCH. 5 EXISTING STOREFRONT TO REMAIN. WINDOWS ARE FIXED AND NOT OPERABLE. INDICATES WALL BLOCKING. BLOCKING TO BE PROVIDED AS REQUIRED TO SUPPORT WALL ATTACHMENTS. EXTEND BLOCKING 4" (100mm) BEYOND EDGE OF ATTACHMENTS. LEGEND WALL TILE START POINT DATUM 6" 2' - 1 0 " 5' - 0 " 6' - 6 " 10 ' - 1 1 " B. O . B A F F L E S 11 ' - 2 " B. O . E X I S T I N G R O O F 15 ' - 4 " V I F 10 ' - 1 1 " 11 ' - 1 0 " B 18735 WD0073 MAD303-V SW7031 SW7031 CP0030 SW7031 (ES) (ES) 13 TY P . 2 1 / 4 " CP0030 6" 10 ' - 1 1 " B. O . T R A C K L I G H T 11 ' - 0 1 / 2 " B. O . B A F F L E S 11 ' - 2 " 15 ' - 4 " 3' - 9 " 2' - 6 " 7' - 1 0 3 / 4 " B. O . L I G H T F I X T U R E 10 ' - 4 3 / 4 " 10 ' - 1 1 1 / 4 " 11 ' - 1 0 " B 18735 G 22043 3" 2' - 1 1 1 / 2 " 4 3 / 4 " G 23136 D 23135 13 D 23129 15 D 23130 10 SW7103 SW7749 Q 17778 SW7749 Q 17778 SW7103 SW7103 WD0073 C X1009 MT0029 SW7103 SW7103SW7103 (ES) (ES)(ES) (ES) (ES) (ES) EQEQ 1 2 3 4 5 5 7 8 14 9 F X22488 F X22488 F X22488 F X22488 11 11 11 11 12 1' - 10" B 18735 GTK0074 SW7031 WD0073 WD0073 MAD101-V C X1007 SW7749 Q 17778 6" 10 ' - 1 1 " 6' - 1 3 / 4 " (ES) (ES) 6 10 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 1 9 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I201 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES INTERIOR FINISH ELEVATIONS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 Revision Schedule Rev Date By Description 3/8" = 1'-0"1CAFE ELEVATION A 3/8" = 1'-0"3CAFE ELEVATION C3/8" = 1'-0"15CAFE ELEVATION E NOT USED B 18735 GTK0074 SW7031 WD0073 WD0073 MAD101-V C X1007 SW7749 Q 17778 6" 10 ' - 1 1 " 6' - 1 3 / 4 " (ES) (ES) 6 10 STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON SHEET I601. B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION. C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE INDICATED. D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE: 1) WOODS AND METAL SURFACES SHALL BE SEMI-GLOSS OR EQUAL. 2) ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL. a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL. 3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR EQUAL. E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN ORDERING PAINTS. F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH. G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE SEALED. H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION. I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F. L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING BACK BAR TILE. M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. N. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE - RUN BACKBAR WALL TILE TO UNDERSIDE OF WALL CABINETS - NOT BEHIND CABINETS. O. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING. P. ALL PAINTED SURFACES TO RECEIVE A MINIMUM ONE COAT OF PRIMER. SEE PAINT SCHEDULE FOR SPECIFICATIONS. Q. PAINT SHALL NOT BE APPLIED OVER EXISTING MURALS OR VINYL WALLCOVERING. R. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O. S. SEE I402 ENLARGED RESTROOM PLAN DETAILS FOR ACCESSORY MOUNTING HEIGHTS. T. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. U. CASEWORK, COUNTERTOPS AND WALL MOUNTED FURNISHINGS TO BE ATTACHED TO SUPPORTING MEMBERS PER PRODUCT MANUFACTURER'S SPECIFICATIONS. V. TILE BASE - REFER TO I104 FOR DESIGN ID TAG AND DETAILS. KEYNOTES GENERAL NOTES 1 ARTWORK -REFER TO SCHEDULE "G" ON SHEET I601 2 WALL MOUNTED OSB "ORDER STATUS BOARD". PROVIDE POWER PER DETAIL 3/I504 4 1" X 1" HORIZONTAL METAL TRIM -MT0029 3 EXISTING STOREFRONT TO REMAIN. WINDOWS ARE FIXED AND NOT OPERABLE. 5 RELOCATED EXISTING ENERGY MANAGEMENT SYSTEM. 6 TRIM AROUND THE OPENING. 1" X 1" WOOD + SW7741 PAINT 7 FULL HEIGHT WALL WOOD CLADDING. WD0073 + MAD101-V 8 NEW ROLLER SHADE. INDICATES WALL BLOCKING. BLOCKING TO BE PROVIDED AS REQUIRED TO SUPPORT WALL ATTACHMENTS. EXTEND BLOCKING 4" (100mm) BEYOND EDGE OF ATTACHMENTS. LEGEND WALL TILE START POINT DATUM 6" 7' - 1 0 3 / 4 " LI G H T C O V E 6" 10 ' - 1 1 " LI G H T C O V E 6" 10 ' - 1 1 " 15 ' - 4 " V I F 2' - 1 0 " 5" WD0073 MAD101-V C X1007 G 22922 SW7103 SW7103 B 18735 SW7031SW7031 B. O . B A F F L E S 11 ' - 2 " (ES) (ES) (ES) 1 7 I502C 9 6" 2' - 1 0 " 3' - 3 " 4' - 1 0 " 6' - 6 " 7' - 1 0 3 / 4 " 10 ' - 1 1 " 3' - 9 3 / 4 " 3' - 8 3 / 4 " 6" 3' - 9 " 2' - 6 " 6' - 2 " 7' - 1 0 3 / 4 " 10 ' - 1 1 " A 22970 A 23021 Q 22817 CP0030 SW7103SW7103 SW7749 Q 17778 G 21491 WD0073 B 18735 (SG)(ES) (ES) CP0030 MT0029 C X1009 MT0029 C X1009 EQ EQ 1 2 3 4 4 F X22488 F X22488 F X22488 F X22488 8 8 8 8 1' - 10" MT0029 SW7103 SW7741 Q 17778 C X1009 OPEN TO PARTNER AREA (ES) (ES) 3' - 1 " 9' - 0 " B 18735 4 B 18735 MT0029 Q 17778 SW7103 SW7741 C X1009 (ES) (ES) 6" 3' - 1 " 9' - 0 " SW7103(ES) 5 4 SW7741 MT0029 SW7103 Q 17778 B 18735 C X1009 6" 3' - 1 " 9' - 0 " (ES) (ES) 4 Q 17778 SW7741 SW7103 MT0029 C X1009 B 18735 (ES) (ES) 6" 3' - 1 " 9' - 0 " 7' - 0 " 4 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 2 1 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I202 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES INTERIOR FINISH ELEVATIONS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 Revision Schedule Rev Date By Description 3/8" = 1'-0"1CAFE ELEVATION B 3/8" = 1'-0"3CAFE ELEVATION D 3/8" = 1'-0"13MANAGER AREA ELEVATION A 3/8" = 1'-0"14MANAGER AREA ELEVATION B 3/8" = 1'-0"15MANAGER AREA ELEVATION C 3/8" = 1'-0"16MANAGER AREA ELEVATION D 6" 7' - 1 0 3 / 4 " LI G H T C O V E 6" 10 ' - 1 1 " LI G H T C O V E 6" 10 ' - 1 1 " 15 ' - 4 " V I F 2' - 1 0 " 5" WD0073 MAD101-V C X1007 G 22922 SW7103 SW7103 B 18735 SW7031SW7031 B. O . B A F F L E S 11 ' - 2 " (ES) (ES) (ES) 1 7 I502C 9 6" STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON SHEET I601. B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION. C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE INDICATED. D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE: 1) WOODS AND METAL SURFACES SHALL BE SEMI-GLOSS OR EQUAL. 2) ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL. a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL. 3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR EQUAL. E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN ORDERING PAINTS. F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH. G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE SEALED. H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION. I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F. L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING BACK BAR TILE. M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. N. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE - RUN BACKBAR WALL TILE TO UNDERSIDE OF WALL CABINETS - NOT BEHIND CABINETS. O. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING. P. ALL PAINTED SURFACES TO RECEIVE A MINIMUM ONE COAT OF PRIMER. SEE PAINT SCHEDULE FOR SPECIFICATIONS. Q. PAINT SHALL NOT BE APPLIED OVER EXISTING MURALS OR VINYL WALLCOVERING. R. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O. S. SEE I402 ENLARGED RESTROOM PLAN DETAILS FOR ACCESSORY MOUNTING HEIGHTS. T. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. U. CASEWORK, COUNTERTOPS AND WALL MOUNTED FURNISHINGS TO BE ATTACHED TO SUPPORTING MEMBERS PER PRODUCT MANUFACTURER'S SPECIFICATIONS. V. TILE BASE - REFER TO I104 FOR DESIGN ID TAG AND DETAILS. KEYNOTES GENERAL NOTES 1 1/8" SOFFIT CLADDING REVEAL, TYP. 2 ALIGN TOP OF 1" X 1" METAL TRIM WITH BOTTOM OF SOFFIT 3 WALL FINISH BEHIND EXPOSED CABINETRY AND BELOW UNDERSIDE OF COUNTERTOP SUBSTRATE TO BE FRP. 4 NEW 1" X 1" METAL TRIM -MT0029 5 EXISTING STOREFRONT TO REMAIN. WINDOWS ARE FIXED AND NOT OPERABLE. 6 RELOCATED EXISITNG TEMPERATURE SENSOR 7 RELOCATED EXISTING OCCUPANCY SENSOR 8 TRAFFIC DOOR, FINISHED PER SCHEDULE 9 PROVIDE POWER/DATA FOR DIGITAL MENU BOARDS PER DETAIL 1/I504 10 PROVIDE 6" MIN. SST INTEGRAL SPLASHGUARD AT HAND SINK ON BOTH SIDES 11 NEW DRIVE THRU WINDOW. INDICATES WALL BLOCKING. BLOCKING TO BE PROVIDED AS REQUIRED TO SUPPORT WALL ATTACHMENTS. EXTEND BLOCKING 4" (100mm) BEYOND EDGE OF ATTACHMENTS. LEGEND WALL TILE START POINT DATUM 5" 2' - 1 0 " 4' - 1 0 " 7' - 1 0 3 / 4 " 10 ' - 1 1 " Q 22817 PL0027 MT0029 C X1009 TYP. A 22970 A 22972 (3) PL0027 PL0003CP0030 PL0027 Q 22817 TYP.TYP.B X19795 3' - 1 0 " 5' - 0 " 11' - 0 1/4"6' - 7 1/4" 2' - 1 " 8' - 1 1 / 4 " 7' - 0 " TYP. 2' - 1 1/2" 1 2 33 4 8 9 10 6" 6" 2' - 1 0 " 5' - 0 " 10 ' - 1 1 " 4' - 1 0 " B X19795 TYP. CP0030 TYP. 6' - 6 " OPEN TO CAFE 6" 7' - 7 " 9' - 6 " 7' - 9 3 / 4 " 10 ' - 1 1 " 11 ' - 5 " 8' - 4 3 / 4 " 6" 6" SW7103 MT0029 C X1009 Q 22817 B X19795 Q 22817 (SG) (SG)SW7103MT0029 C X1009 PL0003 PL0003 PL0003 4 4 2' - 1 0 " 5" 2' - 1 0 " 6" 7' - 1 0 3 / 4 " LI G H T C O V E 6" 10 ' - 1 1 " LI G H T C O V E 6" 7' - 1 0 3 / 4 " B X19795 B 18735 MT0029 SW7749 Q 22817 SW7103 C X1009 (SG)(ES) Q 17778 4 6 7 I502C 3 6" 6" 2' - 1 0 " 3' - 3 " 9' - 6 " 7' - 7 " MT0029 SW7103 Q 22817 B X19795 C X1009 PL0003 CP0030 (SG) 3 4 11 5 10 WX21987 I203 14 2' - 1 0 " 5"7' - 0 " 9' - 6 " 6" 7' - 7 " PL0003 MT0029 SW7103 Q 22817 C X1009 CP0030 B X19795 (SG) 3 4 OPEN TO BACKBAR 2"4' - 1 1/2"2" 2" 9" 2" 2' - 1 1 3 / 4 " 11 I501 12 I501 15 I501 STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 6 / 2 0 2 4 1 2 : 1 2 : 0 8 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I203 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES INTERIOR FINISH ELEVATIONS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 3/8" = 1'-0"1BACKBAR ELEVATION A 3/8" = 1'-0"2BACKBAR ELEVATION B 3/8" = 1'-0"3BACKBAR ELEVATION D 3/8" = 1'-0"4BACKBAR ELEVATION C3/8" = 1'-0"12BACKBAR ELEVATION E 3/8" = 1'-0"11BACKBAR ELEVATION F NOT USED 3/4" = 1'-0"14ENLARGED DT WINDOW Revision Schedule Rev Date By Description 2301 N Tustin Ave #A8/22/2024 A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON SHEET I601. B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION. C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE INDICATED. D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE: 1) WOODS AND METAL SURFACES SHALL BE SEMI-GLOSS OR EQUAL. 2) ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL. a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL. 3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR EQUAL. E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN ORDERING PAINTS. F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH. G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE SEALED. H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION. I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F. L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING BACK BAR TILE. M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. N. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE - RUN BACKBAR WALL TILE TO UNDERSIDE OF WALL CABINETS - NOT BEHIND CABINETS. O. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING. P. ALL PAINTED SURFACES TO RECEIVE A MINIMUM ONE COAT OF PRIMER. SEE PAINT SCHEDULE FOR SPECIFICATIONS. Q. PAINT SHALL NOT BE APPLIED OVER EXISTING MURALS OR VINYL WALLCOVERING. R. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O. S. SEE I402 ENLARGED RESTROOM PLAN DETAILS FOR ACCESSORY MOUNTING HEIGHTS. T. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. U. CASEWORK, COUNTERTOPS AND WALL MOUNTED FURNISHINGS TO BE ATTACHED TO SUPPORTING MEMBERS PER PRODUCT MANUFACTURER'S SPECIFICATIONS. V. TILE BASE - REFER TO I104 FOR DESIGN ID TAG AND DETAILS. KEYNOTES GENERAL NOTES 14 RELOCATED EXISTING LOCKERS. 15 PARTNER REST AREA COAT HOOK. 1 RELOCATED EXISTING DATA RACK. 2 WALL FINISH BEHIND EXPOSED CABINETRY AND BELOW UNDERSIDE OF COUNTERTOP SUBSTRATE TO BE FRP. 8 NEW LUTRON PANEL. 3 NEW ACCESSIBLE UNISEX RESTROOM SIGNAGE -SEE DETAIL 3/G004 4 EXISTING STOREFRONT TO REMAIN. WINDOWS ARE FIXED AND NON-OPERABLE. 5 EXISTING ELECTRICAL PANELS TO REMAIN IN PLACE. 6 RELOCATED EXISTING FIRE EXTINGUSHER 7 WALL MOUNT HAND SINK WITH SOAP AND PAPER TOWEL DISPENSER. G.C. TO PROVIDE BLOCKING FOR FASTENERS. 9 ACCESSIBLE UNISEX RESTROOM SIGNAGE -SEE DETAIL 3/G004 10 TRIM AROUND THE OPENING. 1" X 1" WOOD + SW7741 PAINT 11 PARTNER RECOGNITION BOARD. PROVIDED BY ARTWORK VENDOR. 12 NEW RESTROOM DOOR. FINISHED PER SCHEDULE 13 NEW 1" X 1" METAL TRIM -MT0029 16 PARTNER REST AREA MIRROR. 17 RELOCATED OCCUPANCY SENSOR. INDICATES WALL BLOCKING. BLOCKING TO BE PROVIDED AS REQUIRED TO SUPPORT WALL ATTACHMENTS. EXTEND BLOCKING 4" (100mm) BEYOND EDGE OF ATTACHMENTS. LEGEND WALL TILE START POINT DATUM 6" 2' - 1 0 " 5" 7' - 7 " 9' - 6 " 7' - 1 0 3 / 4 " 10 ' - 1 1 " LI G H T C O V E 6" LI G H T C O V E 6"PL0027 MT0029 C X1009 SW7103 Q 22817 B X19795 OPEN TO BACKBAR PL0003 PL0003 TYP. CP0030 (SG) 13 2 OPEN TO WORKROOM 6" 3' - 1 " 9' - 0 " 4' - 3 " 1' - 4 1 / 2 " 4' - 0 " 5" 2' - 1 0 " 5' - 0 " B. O . H E A D E R 7' - 0 " SW7103 MT0029 Q 17778 SW7741 SW7103 B 18735 C X1009 CP0030 (ES) (ES) (ES) 13 16 15 (ES) 9' - 0 " Q 22817 PL0003 PL0027 SW7103 PL0027 B 18735 14 2 6" 2' - 1 0 " 5" 5' - 0 " CP0030 OPEN TO MANAGER AREA WD0073 6" 3' - 1 " 9' - 0 " 2' - 1 0 " 5" 3' - 3 " 5' - 0 " SW7741 Q 17778 MT0029 SW7103SW7741 B 18735 C X1009 (ES) (ES) (ES) 12 9 13 B. O . H E A D E R 7' - 0 " 6" 3' - 1 " 9' - 0 " 3' - 5 " 4' - 0 " MT0029 SW7741 Q 17778 SW7103 C X1009 B 18735 (ES) (ES) 13 11 GX22178 3' - 10" EQ EQ WD0073 2' - 0 " 6" 10 ' - 0 " B X19795 Q 11469 8 55 17 Q 11469 Q 11469 B X19795 6" 10 ' - 0 " 4' - 6 " 4' - 8 " 7 6 OPEN TO PARTNER AREA B X19795 Q 11469Q11469 6" 10 ' - 0 " 1 B. O . H E A D E R 7' - 0 " 17 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 : 4 7 : 2 9 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I204 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES INTERIOR FINISH ELEVATIONS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 Revision Schedule Rev Date By Description 3/8" = 1'-0"1BACKBAR ELEVATION G3/8" = 1'-0"9PARTNER REST ELEVATION A 3/8" = 1'-0"2PARTNER REST ELEVATION B3/8" = 1'-0"10PARTNER REST ELEVATION C 3/8" = 1'-0"6PARTNER REST ELEVATION D 3/8" = 1'-0"3WORKROOM ELEVATION B 3/8" = 1'-0"4WORKROOM ELEVATION D3/8" = 1'-0"12WORKROOM ELEVATION C NOT USED STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 INDICATES WALL BLOCKING. BLOCKING TO BE PROVIDED AS REQUIRED TO SUPPORT WALL ATTACHMENTS. EXTEND BLOCKING 4" (100mm) BEYOND EDGE OF ATTACHMENTS. LEGEND WALL TILE START POINT DATUM A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON SHEET I601. B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION. C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE INDICATED. D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE: 1) WOODS AND METAL SURFACES SHALL BE SEMI-GLOSS OR EQUAL. 2) ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL. a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL. 3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR EQUAL. E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN ORDERING PAINTS. F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH. G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE SEALED. H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION. I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F. L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING BACK BAR TILE. M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. N. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE - RUN BACKBAR WALL TILE TO UNDERSIDE OF WALL CABINETS - NOT BEHIND CABINETS. O. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING. P. ALL PAINTED SURFACES TO RECEIVE A MINIMUM ONE COAT OF PRIMER. SEE PAINT SCHEDULE FOR SPECIFICATIONS. Q. PAINT SHALL NOT BE APPLIED OVER EXISTING MURALS OR VINYL WALLCOVERING. R. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O. S. SEE I402 ENLARGED RESTROOM PLAN DETAILS FOR ACCESSORY MOUNTING HEIGHTS. T. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. U. CASEWORK, COUNTERTOPS AND WALL MOUNTED FURNISHINGS TO BE ATTACHED TO SUPPORTING MEMBERS PER PRODUCT MANUFACTURER'S SPECIFICATIONS. V. TILE BASE - REFER TO I104 FOR DESIGN ID TAG AND DETAILS. KEYNOTES GENERAL NOTES 1 NEW TRAFFIC DOOR. FINISH PER SCHEDULE. 2 NEW MOP HOOK 3 NEW ICE MACHINE/ DIVERTER/ ICE BIN ADAPTOR PEDESTAL. (SEE PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION). 4 EXISTING EMERGENCY EXIT SIGN/LIGHT TO REMAIN IN PLACE. 5 EXISTING AIR CURTAIN ABOVE DOOR TO REMAIN. 6 EXISTING EXIT ONLY DOOR WITH SURLOCK TO REMAIN. 7 RELOCATED EXISITNG TEMPERATURE SENSOR B X19795 Q 11469 6" 10 ' - 0 " 10 " 6" 7' - 0 " 12 ' - 6 " 9' - 6 " 6 4 5 3 B X19795 Q 11469 Q 11469 6" 10 ' - 0 " 10 " 7' - 0 " 6" 9' - 6 " 12 ' - 6 " PL0027 1 3 2 5' - 1 0 " 10 " 7' - 0 " 6" 12 ' - 6 " B X19795 Q 11469 Q 11469 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 3 1 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I205 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES INTERIOR FINISH ELEVATIONS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 Revision Schedule Rev Date By Description 3/8" = 1'-0"2WORKROOM ELEVATION A 3/8" = 1'-0"3WORKROOM ELEVATION E 3/8" = 1'-0"4WORKROOM ELEVATION F NOT USEDNOT USED NOT USEDNOT USED STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 KEYNOTES GENERAL NOTES A. GENERAL CONTRACTOR TO SCHEDULE WITH LOCAL REFRIGERATION CONTRACTOR TO CONDUCT INITIAL FOOD CASE START-UP AND TESTING. FOR APPROVED CONTRACTOR, CONTACT VENDOR. B. THE SITE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM UNLESS OTHERWISE NOTED. C. ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION FOUNDATION STANDARDS OR EQUIVALENT. D. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS, EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR ACCUMULATION OF DUST, DIRT AND DEBRIS. E. WARMING OVEN(S) SHOWN FOR PERMITTING PURPOSES. INSTALLATION AT STORE OPENING TO BE VERIFIED BY STARBUCKS CONSTRUCTION REPRESENTATIVE. F. EACH HAND WASHING SINK WILL HAVE A SINGLE SERVICE TOWEL AND SOAP DISPENSER, AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR PREMIXING FAUCET. G. SEE SHEET I601 FOR SCHEDULES. H. G.C. TO CONFIRM CASEWORK DELIVERY DATE WITH CONSTRUCTION MANAGER PROVIDING A MINIMUM SCHEDULING NOTICE OF 4 WEEKS AND 1 WEEK PRIOR TO SCHEDULED DATE OF DELIVERY. I. SEE WALL FINISH PLAN FOR LOCATION, TAGGING AND FINISH SCHEDULES OF APPLIED WALL TREATMENT. J. EDIBLE PRODUCTS TO BE PHYSICALLY SEPARATED FROM STORAGE OF NON- EDIBLE OR TOXIC PRODUCTS. K. NO VEGETABLE OR FOOD PREPARATION ON THE PREMISES. L. NO ALCOHOLIC BEVERAGES TO BE SOLD OR CONSUMED ON THE PREMISES. M. THE MAXIMUM NUMBER OF EMPLOYEES PER SHIFT SHALL NOT EXCEED 4. N. NON-MOVABLE EQUIPMENT ON THE FLOOR SHALL BE MOUNTED ON 6" LEGS, CASTERS OR MANUFACTURER SUPPLIED SKIDS. O. ALL EQUIPMENT, CONSTRUCTION, AND INSTALLATION SHALL MEET ANSI CERTIFICATION. ALL PLUMBING, GAS LINES AND CONDUITS, ETC., ARE TO BE CONCEALED WHERE POSSIBLE. OTHERWISE, THEY MUST BE A MINIMUM OF SIX INCHES OFF THE FLOOR AND NOT RUN ACROSS AISLE SPACE AND TO BE INSTALLED AT LEAST 1/2" AWAY FROM THE WALL TO FACILITATE CLEANING. ALL EQUIPMENT AND BACKSPLASHES ARE TO BE ADEQUATELY SEALED TO THE WALL. DISPLAYS OF UNPACKAGED FOOD ARE TO BE PROTECTED WITH SNEEZE GUARDS. ALL EXPOSED SURFACES OF SHELVING, CABINETS AND UNDERCOUNTERS ARE TO BE SMOOTH AND SEALED. P. G.C. TO CAULK WHERE COUNTERTOPS MEET FOOD CASE (SEAL WITH THE DEPARTMENT OF ENVIRONMENTAL HEALTH APPROVED CAULKING). Q. NON-MOVABLE EQUIPMENT ON THE COUNTER SHALL BE MOUNTED ON 4" LEGS. R. REFER TO CASEWORK INSTALLATION MANUAL PROVIDED BY CASEWORK VENDOR FOR COMPLETE INSTALLATION INSTRUCTION. S. FOR ALL NEW CASEWORK ITEMS BASE UNITS SHALL BE SET ON 1/4" NON- ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR. T. CAULK AND SEAL ALL SEAMS BETWEEN SS COUNTERTOPS USING DOW CORNING BRAND '732 MULTI PURPOSE SEALANT'. U. STAINLESS STEEL TOP AT CBS STATION TO BE INSTALLED BY G.C. V. G.C. TO PROVIDE AND INSTALL ANGLE AT OUTSIDE CORNERS TYP. AND ALONG BOTTOM EDGE OF CASEWORK PANELS. W. ALL FOOD STORAGE SHALL BE 6" (150mm) A.F.F. X. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETS) SHALL BE SEALED. Y. ALL EQUIPMENT AND CABINETRY WILL BE FLUSH MOUNTED TO COUNTERS, WALLS OR FLOORS, OR BE RAISED TO ALLOW FOR CLEANING. Z. CONFIRM ALL NECESSARY EQUIPMENT CLEARANCES PER PRODUCT CUT SHEET (E.G. ICE MACHINE). AA. FOR LOCATION OF COUNTERTOP EQUIPMENT, REFER TO CASEWORK ELECTRICAL DETAILS. BB. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING DESIGN PLAN. FOR DATA DEVICE SCHEDULE, REFER TO THE ELECTRICAL DESIGN PLAN. CC. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM THE LOCAL JURISDICTION. 1 LED LIGHT STRIP W/HOUSING MOUNTED TO UNDERSIDE OF UPPER CABINETRY EXISTING ITEMS TO PRESERVE AND RELOCATE A BLENDERS (2) B ESPRESSO MACHINES (2) C SAFE Q WATER FILLING STATION K WARMING OVEN (2) T 2-DR REACH IN FRIDGE (2) S 2-DR REACH IN FREEZER D WARMING U/C FRIDGE (2) P MANAGER'S STATION EQUIPMENT R 1-DR REACH IN FREEZER E 1-DR U/C FRIDGE (5) M DRIVE-THRU POS EQUIPMENT L POS EQUIPMENT, PRINTER, & PHONE H NITRO TAP / NITRO GENERATOR G CUP LABELER (4) F GRINDER V THAW RACK U SANITIZER W R.O. SYSTEM & WATER HEATER X TRASH BIN I NOT USED J CUP CADDY (2) N PASTRY CART O AV DIGITAL PRODUCTION MANAGER Y METRO RACKS (10) Z ICE BIN A1 HAND DRYER (2) B1 DATA RACK C1 LOCKERS (2) P 22768 P 22642 P 11003 P 10153 P 22768 P 10153 P 22642 P 11003 E 19278 E 19278 E 16238 P 10549 P 10152 P 10597 E 10992 E 11115 E 21934 E 23445 E 10992 P 10597 E 11115 E 23444 E 23445 A 23021 A 22970 (2) E 22885 E 23381 E 23380 E 23442 H A A B B C D E E E E F G G J J K K L M N O I400 2 E E 12618 D P 17565 E 17564 P 10153 P 10215 L 22216 E 20010 G BACKBAR A 20294 E 10267 G (2) L=5'-5 1/2" 1 E 23421 L 22220 E 23420E23419 E 23393 E 23419 E 23393 E 23419 E 23393 STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 5 / 2 0 2 4 1 0 : 2 2 : 4 4 A M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I400 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ENLARGED ENGINE PLAN 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 1/2" = 1'-0"1ENLARGED FF&E PLAN N 1/2" = 1'-0"2ENLARGED FF&E UPPER PLAN Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments A 2301 N Tustin Ave #A8/22/2024 A. GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION MANAGER IMMEDIATELY IF A DISCREPANCY EXISTS BETWEEN CASEWORK SHOP DRAWINGS, EXITING SITE CONDITIONS, ARCHITECTURAL DRAWINGS OR BUILT FIXTURES. ALL DIMENSIONS SHALL BE FIELD VERIFIED BY GC PRIOR TO SHOP DRAWINGS PRODUCTION. B. STARBUCKS CONSTRUCTION MANAGER TO COORDINATE AND SCHEDULE CASEWORK DELIVERY DATE. GENERAL CONTRACTOR TO CONFIRM CASEWORK DELIVERY DATE WITH CASEWORK MANUFACTURER AT FOUR (4) WEEKS PRIOR AND THEN ONE (1) WEEK PRIOR TO SCHEDULED DATE OF DELIVERY. C. STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK VENDOR TO SUPPLY CASEWORK LISTED IN THE CASEWORK SCHEDULE, UNLESS OTHERWISE NOTED. D. CASEWORK VENDOR TO PROVIDE COMPLETE SHOP DRAWINGS AND INSTALLATION PACKAGE TO GENERAL CONTRACTOR TO FACILITATE PROPER INSTALLATION. E. ALL CASEWORK BOX BASE / TOE KICKS SHALL BE SET AND LEVELED USING 1/4" (6 MM) NON-ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR. F. SEE INTERIOR FINISH ELEVATIONS AND SCHEDULES FOR LOCATION AND TAGGING OF WALL TREATMENTS BY CV AND OTHERS. G. SEE REFLECTED CEILING PLAN FOR CASEWORK SOFFIT LOCATIONS. H. REFERENCE PLUMBING AND ELECTRICAL PLANS FOR PLACEMENT OF ELECTRICAL, DATA AND PLUMBING ON FRONT AND BACKLINE OF BAR. I. PROVIDE ACCENT LIGHTING AT FRONT EDGE OF BAR. SEE INTERIOR ELEVATIONS AND ELECTRICAL FOR ADDITIONAL INFORMATION. J. CASEWORK VENDOR TO ENGINEER PROPER COUNTERTOP SUPPORT AT ESPRESSO BAR AND OTHER WORKSTATIONS PER STARBUCKS MINIMUM PERFORMANCE REQUIREMENTS. K. REFER TO CASEWORK INSTALLATION MANUAL PROVIDED BY CASEWORK VENDOR FOR COMPLETE INSTALLATION INSTRUCTIONS. L. SEE SHEET I-601 FOR SCHEDULES. M. G.C. TO MODIFY CASEWORK PER CASEWORK DETAILS. N. STORAGE RACKS OR SHELVINGS OVER 5'-9" IN HEIGHT SHALL BE MECHANICALLY SECURED. GENERAL NOTES 1' - 3"3' - 9"2' - 6 1/4"3' - 1 1/4" CLEAR 4' - 4"2' - 6 1/2" CLEAR - WARMING WALL 3' - 5 3/4"8' - 1 3/4" CLEAR 4' - 0 1/2"1' - 10" 11' - 7 1/2" CLEAR 4' - 0 1/2"1' - 10"1' - 3"8' - 11 3/4"1' - 3" CLEAR 6' - 1 1/2" 7' - 8 1/4"3' - 9"1' - 7"4' - 6"1' - 9"6' - 10" CLEAR - FOOD CASE 5' - 6 1/4"5 1/2" CLEAR 3' - 0" 2' - 6 1 / 2 " CL E A R 4' - 6 " 2" 2' - 6 1 / 2 " 3' - 4 " CL E A R 4' - 8 " 2' - 6 1 / 2 " 4" 4" 6 1 / 2 " 4" 1' - 0 1 / 4 " 4" 11 1/2"1 3/4" 9 3/4"1' - 5 3/4" 6" 1' - 0 " 6" 1' - 5 1 / 4 " 2 1 / 2 " 2' - 2 " 7"1' - 5"9' - 2" 1' - 1 1/4"4' - 1" 2' - 3"2' - 3 1/2" 5' - 11"3' - 8 3/4" 1' - 5 1 / 4 " 1' - 1 1 " 8"5' - 0"8"5' - 0 1/4" 3' - 7"2' - 3" 2' - 3"4' - 0 1/4" 3' - 4 1 / 2 " 10 " 6' - 6 " 10 " 4' - 8" 2' - 6"1' - 10 1/2" 5 1 / 4 " 2' - 1 " 8 3 / 4 " 8 3 / 4 " ø 4" ø 2 1/4" ø 4" ø 4"ø 4" ø 4" ø 2" ø 4" ø 4" ø 4"ø 4" ø 3"ø 3" #4 BRUSHED 16GA CP0030 CP0030 CP0030 CP0030 CP0030 CP0030 CP0030 CP0030 CP0030 #4 BRUSHED 16GA CP0030 CP0030 1' - 3 " 6 1/2" C 17810 C 23433 C 17807 C X17827 C X17895 C 17810 C 17741 C 18883C17830 C 20063 C 20061C20271 C 23409 C 21958 CP0030 C 18720 CP0030 CP0002 BACKBAR C 10163 r 11 3/4" 5" 1' - 6 " 1' - 7 " ø 4" ø 3" 8 1/2" C 20066 CP0030 1 8 " M I N 2' - 0 " 1 8 " M I N 2' - 0 " INDICATES STAINLESS STEEL (SST) COUNTERTOP LEGEND INDICATES SOLID SURFACE (SS) COUNTERTOP DATUM POINT 5' - 7 1 / 4 " 5 1/4"1' - 4 3/4"9 3/4" 5" 11 1 / 4 " 2' - 7 1/2" CP0030 C 23151 PARTNER / MANAGER AREA STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 8 / 2 0 2 4 2 : 4 0 : 2 0 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I401 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ENLARGED CASEWORK PLAN 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 1/2" = 1'-0"1ENLARGED COUNTERTOP DIMENSION PLAN N 1/2" = 1'-0"2ENLARGED PARTNER AREA COUNTERTOP DIMENSION PLAN Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments AA 2301 N Tustin Ave #A8/22/2024 INDICATES STAINLESS STEEL (SST) COUNTERTOP LEGEND INDICATES SOLID SURFACE (SS) COUNTERTOP DATUM POINT BACKBAR 1' - 3"2' - 6"1' - 3"2' - 6 1/4"2' - 10 1/4"3" 3' - 5 3/4"3"2' - 9 3/4"2' - 7 1/4"1' - 3"1' - 3" 3" 2' - 4 1 / 4 " 1' - 3 " 1' - 3 " 1' - 3 " 3" 2' - 9 " 1' - 3 " 2' - 6 " 5' - 0"1' - 3"1' - 6"1' - 3"2' - 6"4' - 3 1/4"3" 5 1/2" 1' - 3"1' - 3 1/4"1' - 3"2' - 6"1' - 3"1' - 3"2' - 6"1' - 3" 1' - 3"1' - 3"2' - 8 1/4"1' - 3"1' - 3"1' - 0 1/2"2' - 8"1' - 9 1/4"1' - 4 3/4"2' - 11"1' - 9 1/2"2' - 6"1' - 10"2' - 6"5' - 6 1/4"1 1/2"1" 2" 2' - 4 " 4 3 / 4 " 1 1 / 2 " 1" 2' - 1 0 1 / 4 " 2" 1 3 / 4 " 2' - 4 3 / 4 " 2" 2' - 4 3 / 4 " 1 1/2" 1' - 7 1/4" 2' - 4 3/4" 1 1 / 2 " 2' - 3 1 / 4 " C 17810 C 17747 C 23426 C 17573 C 17573 C 20633 C 17747 C 17747 C 17747 C 17573 C X17741 C X17741 C X17741 C 17894 C 19343 C 17894 C 17741 C 17741 C 17574 C 17740 C 17745 C 17896 C 17740 C 17741 C 18885 C 18884 C 21192C 17744C 21192 C 20064 C 17831 C 17832C11155 C 18145 C 20633C21191C21191 C 17747 C 23388 C 17741 C 18865 C 18717 (4)(4) C 20065 I502C 1 I502 6 17 I502A 1 I502 15 I502 1 I502A (4) C 21191 C 21190 A. GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION MANAGER IMMEDIATELY IF A DISCREPANCY EXISTS BETWEEN CASEWORK SHOP DRAWINGS, EXITING SITE CONDITIONS, ARCHITECTURAL DRAWINGS OR BUILT FIXTURES. ALL DIMENSIONS SHALL BE FIELD VERIFIED BY GC PRIOR TO SHOP DRAWINGS PRODUCTION. B. STARBUCKS CONSTRUCTION MANAGER TO COORDINATE AND SCHEDULE CASEWORK DELIVERY DATE. GENERAL CONTRACTOR TO CONFIRM CASEWORK DELIVERY DATE WITH CASEWORK MANUFACTURER AT FOUR (4) WEEKS PRIOR AND THEN ONE (1) WEEK PRIOR TO SCHEDULED DATE OF DELIVERY. C. STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK VENDOR TO SUPPLY CASEWORK LISTED IN THE CASEWORK SCHEDULE, UNLESS OTHERWISE NOTED. D. CASEWORK VENDOR TO PROVIDE COMPLETE SHOP DRAWINGS AND INSTALLATION PACKAGE TO GENERAL CONTRACTOR TO FACILITATE PROPER INSTALLATION. E. ALL CASEWORK BOX BASE / TOE KICKS SHALL BE SET AND LEVELED USING 1/4" (6 MM) NON-ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR. F. SEE INTERIOR FINISH ELEVATIONS AND SCHEDULES FOR LOCATION AND TAGGING OF WALL TREATMENTS BY CV AND OTHERS. G. SEE REFLECTED CEILING PLAN FOR CASEWORK SOFFIT LOCATIONS. H. REFERENCE PLUMBING AND ELECTRICAL PLANS FOR PLACEMENT OF ELECTRICAL, DATA AND PLUMBING ON FRONT AND BACKLINE OF BAR. I. PROVIDE ACCENT LIGHTING AT FRONT EDGE OF BAR. SEE INTERIOR ELEVATIONS AND ELECTRICAL FOR ADDITIONAL INFORMATION. J. CASEWORK VENDOR TO ENGINEER PROPER COUNTERTOP SUPPORT AT ESPRESSO BAR AND OTHER WORKSTATIONS PER STARBUCKS MINIMUM PERFORMANCE REQUIREMENTS. K. REFER TO CASEWORK INSTALLATION MANUAL PROVIDED BY CASEWORK VENDOR FOR COMPLETE INSTALLATION INSTRUCTIONS. L. SEE SHEET I-601 FOR SCHEDULES. M. G.C. TO MODIFY CASEWORK PER CASEWORK DETAILS. N. STORAGE RACKS OR SHELVINGS OVER 5'-9" IN HEIGHT SHALL BE MECHANICALLY SECURED. GENERAL NOTES PARTNER / MANAGER AREA 3" 2' - 7 1 / 4 " 1' - 3 " 1' - 3 " 3" 2' - 4 3/4" C 17573 C 17747 C 17574 C 17573 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 3 7 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I401A 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ENLARGED CASEWORK PLAN 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 N 1/2" = 1'-0"1ENLARGED CASEWORK PLAN Revision Schedule Rev Date By Description 1/2" = 1'-0"2ENLARGED PARTNER AREA CASEWORK DIMENSION PLAN STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. B. ALL DIMENSIONS ARE TO BE TAKEN FROM A DESIGNATED DATUM POINT. C. DIMENSIONS ARE TO FACE OF FINISHED SURFACE UNLESS OTHERWISE NOTED. D. DIAPER CHANGING STATION IS TO BE INSTALLED PER MANUFACTURER’S INSTRUCTIONS. UNIT IS TO BE FASTENED TO STRUCTURE AT ALL SIX CHASSIS ATTACHMENT POINTS. (IF APPLICABLE PER PROJECT SCOPE) E. LOCATE DIAPER CHANGING STATION AS SHOWN TO ALLOW NECESSARY CLEARANCE FOR OPERATION OF ALL RESTROOM FIXTURES. LOCATION SHALL NOT IMPEDE ACCESS, EGRESS, OR DOOR SWING. (IF APPLICABLE PER PROJECT SCOPE) F. ALL RESTROOM ACCESSORY MOUNTING HEIGHTS AND CLEARANCES SHALL COMPLY WITH THE ACCESSIBILITY REQUIREMENTS OF THE LOCAL JURISDICTION. GENERAL NOTESKEYNOTES 1 60" ACCESSIBLE TURNING SPACE. 2 30" X 48" CLEAR FLOOR SPACE. 3 WATER CLOSET CLEAR FLOOR SPACE.PER CBC 11B-604 13 NEW COAT HOOK. 4 NEW RESTROOM WALL SCONCE, CENTER SCONCE ABOVE MIRROR 14 FULL TILE AT TOP OF TILED WALL. 5 NEW LAVATORY SINK & FAUCET. FLOW RATE NOT TO EXCEED 0.5 GPM AT 60 PSI 9 NEW WATER CLOSET. NOT TO EXCEED 1.28 GALLON PER FLUSH 6 RELOCATED EXISTING ELECTRICAL HAND DRYER 7 NEW SINK MOUNTED SOAP DISPENSER. 8 BOTTOM OF MIRROR REFLECTIVE SURFACE TO BE 40" AFF. 10 NEW RESTROOM GRAB BAR 11 NEW TOILET PAPER DISPENSER. 12 NEW SEAT COVER DISPENSER. 15 NEW RESTROOM DOOR. FINISH PER SCHEDULE. 16 NEW 1" X 1" HORIZONTAL METAL TRIM -MT0029 2' - 0"1' - 0" 3' - 0" 2' - 9 " 19 " M A X 17 " M I N 1' - 6" 2' - 9 " 1' - 7 " 3' - 5 " 1' - 6 " 3' - 3" 6"4' - 0" 3' - 3 1/2"5 1/4" ELECTRIC HAND DRYER FRONT ELEVATION 4' - 0 " COAT HOOK ELEVATION TOILET FRONT ELEVATION TOILET SIDE ELEVATION 3' - 4 " HAND SINK SIDE ELEVATION 19" MAX 17" MIN 11" MIN 6" MAX 8" MIN 9" M I N 27 " M I N 29 " M I N 34 " M A X OF R E F L E C T I V E S U R F A C E 40 " M A X . T O B O T T O M CLEAR KNEE SPACE WALL MOUNTED LAVATORY 19 " M I N 1' - 9 1 / 4 " CEMENTITOUS BACKER BOARD CONTINUOUS WATERPROOF MEMBRANE. EXTEND 12" (305mm) UP WALL. WALL TILE PER SCHEDULE. ADHERE TO WALL PER MFR'S RECOMMENDATIONS. COVED TILE BASE PER SCHEDULE. ADHERE TO WALL PER MFR'S RECOMMENDATIONS. 3/8" RADIUS AT COVED BASE FINISH FLOOR PER SCHEDULE CONTINUOUS WATERPROOF MEMBRANE APPLIED TO SUBFLOOR. EXTEND EDGE TO 12" (305mm) OFFSET FROM WALL. CONCRETE SLAB WALL TYPE PER LEGEND I402 8 11 10 9 I402 6 4 57 UNISEX PARTNER RESTROOM W.C. CLEARANCE 4' - 8" CLR 4' - 0" WHEEL CHAIR TURNING SPACE ø 5' - 0" W. C . C L E A R A N C E 5' - 0 " 18 " M I N 1' - 6 " 17 " - 1 8 " 1' - 6 " W. C . C L E A R A N C E 5' - 0 " W.C. CLEARANCE 4' - 8" CLR 4' - 0" 18 " M I N 1' - 6 " 2' - 6 " CLEAR 18" MIN 2' - 6 " WHEEL CHAIR TURNING SPACE ø 5' - 0" 4' - 0" 4' - 0" UNISEX CUSTOMER RESTROOM 1 2 3 1 2 3 17 " - 1 8 " 1' - 6 " 12" MAX 7 1/2 " SW7103 6" 2' - 9 " 3' - 4 " 7' - 3 " 9' - 0 " Q 22817 B 18735 14 (SG) WD0073 SW7031 MT0029 C X1009 16 6 15 6" 2' - 9 " B. O . R E F L E C T I V E S U R F . 3' - 3 1 / 4 " 6' - 3 " 9' - 0 " B 18735 Q 22817 SW7103 7' - 3 " 2' - 9 1 / 2 " 7 5 10 9 EQ EQ(SG) MT0029 C X1009 4 16 14 9" B 18735 Q 22817 6" 2' - 9 1 / 2 " 9' - 0 " 7' - 3 " SW7103 1' - 5 " MT0029 C X1009(SG) 16 10 9 11 12 14 SW7103 Q 22817 B 18735 6" 7' - 3 " 9' - 0 " EQ EQ 4' - 0 " MT0029 C X1009(SG) 16 13 14 B 18735 9' - 0 " 4' - 0 " WD0073 SW7741 Q 11469 1513 EQEQ 6" 2' - 9 " B. O . R E F L E C T I V E S U R F . 3' - 3 1 / 4 " 6' - 3 " 9' - 0 " B 18735 6" Q 11469EQEQ 7 5 4 9' - 0 " 8 1/2" Q 11469 9 B 18735 3' - 4 " 2' - 9 1 / 2 " 1' - 5 " 6 10 12 11 6" 2' - 9 1 / 2 " 9' - 0 " B 18735 Q 11469 1' - 5 " 9 10 6" STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 5 / 2 0 2 4 1 0 : 2 2 : 4 9 A M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I402 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ENLARGED RESTROOM ACCESSIBILITY PLAN 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 3/8" = 1'-0"1MOUNTING HEIGHTS FOR RESTROOM ACCESSORIES 6" = 1'-0"2INTEGRAL TILE BASE AT TILED WALL 1/2" = 1'-0"3ENLARGED RESTROOM ACCESSIBILITY PLAN N 3/8" = 1'-0"4UNISEX CUSTOMER RESTROOM ELEVATION A 3/8" = 1'-0"5UNISEX CUSTOMER RESTROOM ELEVATION B 3/8" = 1'-0"6UNISEX CUSTOMER RESTROOM ELEVATION C 3/8" = 1'-0"7UNISEX CUSTOMER RESTROOM ELEVATION D 3/8" = 1'-0"8UNISEX PARTNER RESTROOM ELEVATION A 3/8" = 1'-0"9UNISEX PARTNER RESTROOM ELEVATION B 3/8" = 1'-0"10UNISEX PARTNER RESTROOM ELEVATION C 3/8" = 1'-0"11UNISEX PARTNER RESTROOM ELEVATION D Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments A A 2301 N Tustin Ave #A8/22/2024 HEAVY-DUTY GRID NOTES: 1. LIGHT FIXTURES OR DIFFUSERS IN EXCESS OF 56 LBS REQUIRE (4) 12 GAUGE HANGER WIRES. 2. SUSPENDED CEILING TO COMPLY WITH ASCE 7-16 SECTION 13.5.6.2.2., ASTM C636, CISCA DESIGN REQUIREMENTS 3. CEILINGS SHALL BE SPECIAL INSPECTED PER SECTION 11A.1.3.9 OF ASCE 7.16 (SEE ADDITIONAL NOTES ON RCP) (2) 12 GAUGE HANGER WIRES TO STRUCTURE ABOVE - AT ALTERNATE CORNERS OF ALL 2X4 LIGHT FIXTURES AND HVAC DIFFUSERS 2" OVERSIZED RING ADAPTER AT SPRINKLER HEAD INSTALL COMPRESSION STRUT EA. DIRECTION OR EVERY 144 S.F. OF CEILING AREA PER CBC STANDARDS 47-18 12 GA. WIRES @ 12'-0" O.C. SPLAYED 45° FROM CEILING PLANE CROSS RUNNER @ 2'-0" O.C. 45° - TYP . WA L L MAIN RUNNER @ 4'-0" O.C. NOTE: 1. ALL INTERIOR WALL & CEILING FINISHES SHALL BE FLAME SPREAD CLASS III MIN. 2. SUSPENDED T-BAR SYSTEM SHALL BE 25 GA. MIN. 3. SUSPENDED CEILING TILE SYSTEM TO COMPLY WITH ICC-ESR #1308 4. ALL 24" X 48" LIGHT FIXTURES & 24" X 24" HVAC DIFFUSERS SHALL BE SUPPORTED BY A MIN. OF (2) HANGERS @ OPPOSITE CORNERS - CEILING SYSTEM SHALL NOT SUPPORT OTHER ITEMS. 5. CEILING SYSTEM GRID TO BE HEAVY DUTY. 12 GA HANGER WIRE @ 4'-0" O.C. ALONG EACH MAIN RUNNER 6'-0" MAX. CEILING SYSTEM GRIDTO BE HEAVY DUTY. ++ 1/2 " =.5 L=5' MAX. x 12"=60 PROVIDE COMPRESSION STRUTS @ 12'-0" O.C. EACH DIRECTION (OR 144. S.F. AND WITH 6'-0" OF WALLS 60/.5 = 120 < 200 L/R = < 200 NOTE: 'X' CUT BOTTOM OF CONDUIT (1" DEEP) AND FIT SNUG TO T-BAR INTERSECTION (2) #8 WOOD SCREWS 1" DIA. RIGID CONDUIT COMPRESSION POST JOIST, PURLIN OR SUB-PURLIN (SEE ADDITIONAL NOTES ON RCP) SUSPENDED CEILING TILE SYSTEM TO COMPLY WITH ICC-ESR #1308 SPLICE AS NEEDED WITH 3/4" DIA.BY 6" CONDUIT AND #8 MACHINE SCREWS AND NUTS VA R I E S ( V . I . F . ) B A HANGER WIRE - PARALLEL TO WALL @ 4'-0" O.C. - TYP. MAIN RUNNER - POP RIVET EACH MAIN RUNNER OR CROSS TEE TO WALL ANGLE - PROVIDE ADDTIONAL CLOSURE ANGLES AS REQUIRED ACCOUSTICAL PANEL - TYP. MAIN RUNNER - DO NOT ATTACH TO WALL ANGLE WALL OR SOFFIT - SEE PLAN CONTINUOUS 2" X 2" ANGLE WITH #10 SELF-TAPPING SCREWS AT EACH STUD - TYP. TYP. 8" MAX. ATTACHED (2) ADJACENT WALLS UNATTACHED OPPOSITE WALLS NOTE: MAIN RUNNERS SHALL BE ATTACHED AT (2) ADJACENT WALLS AS SHOWN IN CONDITION 'A' MAIN RUNNERS SHALL BE UNATTACHED AT OPPOSITE WALLS AS SHOWN IN CONDITION 'B' SEE ADDITIONAL NOTES ON REFLECTED CEILING PLAN - SHEET I-121 3/4" CLR. SPREADER BAR AS REQUIRED TO PREVENT SPREADING TABLE FOR NON-BEARING METAL STUDS SSMA PRODUCTS ICC ESR #2054 5 PSI (SIZING PERTAINS TO ALL 'S' WALL TYPES) STUD SIZE AND GAUGE SPACING MAX. HT. 3625125-18 (3 5/8" X 25 GA.) 16" O.C. 14'-4" 3625125-33 (3 5/8" X 20 GA.) 16" O.C. 16'-5" 3625125-43 (3 5/8" X 18 GA.) 16" O.C. 18'-0" 4005125-18 (4" X 25 GA.) 16" O.C. 15'-4" 4005125-33 (4" X 20 GA.) 16" O.C. 18'-4" 4005125-43 (4" X 18 GA.) 16" O.C. 19'-5" 6005125-18 (6" X 25 GA.) 16" O.C. 19'-9" 6005125-33 (6" X 20 GA.) 16" O.C. 24'-6" 6005125-43 (6" X 18 GA.) 16" O.C. 28'-3" SEE DETAIL 13 AND 15 THIS SHEET FOR FULL HEIGHT WALLS. FULL THICKNESS BATT INSULATION - ONLY WHERE INDICATED ON PLANS AND SPECIFICATIONS FRAMING PER PLAN FINISH FLOOR1/ 4 " M A X . 5/8" TYPE 'X' GYP. BD. SHOT PINS - HILTI OR EQUAL @ 24" O.C. LARR. #25646 - ESR # 1663 25 GA. FLOOR TRACK - CONTINUOUS 4X WOOD BLOCKING BETWEEN ROOF TRUSSES AS REQUIRED ROOF FRAMING OR OTHER STRUCTURAL MEMBER CONTINUOUS SLIP TRACK FRAMING PER PLAN- 1" MINIMUM CLEAR FROM ROOF STRUCTURE - TO ALLOW ROOF DIAPHRAM MOVEMENT - SHOT PIN - ICC ESR -1752 5/8" TYPE 'X' GYP. BD. - WHERE OCCURS DO N O T A T T A C H G Y P . B D . AB O V E T H I S P O I N T (2) #10 X 2" WOOD SCREWS @ 24" O.C. SIMPSON TIE HANGER LU FRAMING ANCHOR @ EA END. USE (3) 8-d NAILS, TYP WEB FILLER WHEN APPLICABLE 5/8" TYPE 'X' GYP. BD. ATTACH BRACING TO CONTINUOUS 20 GA. TOP TRACK WITH (2) #10 S.M.S. 3 5/8" METAL STUD WALL BRACING @ 45 DEG. @48" O.C. IN ALTERNATING DIRECTIONS - SAME STUD GAUGE AS WALL FRAMING PER PLAN I501 7 I501 6 FRAMING PER PLAN 5/8" TYPE 'X' GYP BD. EXISTING ROOF & STRUCTURE CONTINUOUS SLIP TRACK ICC-ESR #2054 LARR # 25631 CEILING PER PLAN 6" M I N . 5/8" TYPE 'X' GYP BD. - EXTEND TO UNDERSIDE OF ROOF STRUCTURE WHERE NO CEILING OCCURS NOTES: 1. ALL INTERIOR WALLS TO HAVE GYPSUM BOARD EXTEND TO PROVIDE TIGHT BUTT JOINT TO FLOOR SLAB. NO GAP IN EXCESS OF 1/4" WILL BE ALLOWED. 2. PROVIDE WATER RESISTANT GYPSUM BOARD AT THE INTERIORS OF ALL TOILET ROOMS AND WET WALLS. 3. USE 5/8" TYPE 'X' GYP. BD. THROUGHOUT - U.N.O. 4. PROVIDE SOUND BATT INSULATION AT ALL OFFICE AREAS & RESTROOMS WALLS AND CEILINGS. SIM. NOTES: 1. ALL INTERIOR WALLS TO HAVE GYPSUM BOARD EXTEND TO PROVIDE TIGHT BUTT JOINT TO FLOOR SLAB. NO GAP IN EXCESS OF 1/4" WILL BE ALLOWED. 2. PROVIDE WATER RESISTANT GYPSUM BOARD AT THE INTERIORS OF ALL TOILET ROOMS AND WET WALLS. 3. USE 5/8" TYPE 'X' GYP. BD. THROUGHOUT - U.N.O. 4. PROVIDE SOUND BATT INSULATION AT ALL OFFICE AREAS & RESTROOMS WALLS AND CEILINGS. FRAMING PER PLAN - ATTACH BRACING TO CONTINUOUS TOP TRACK WITH (2) #10 S.M.S. 3 5/8" METAL STUD WALL BRACING @ 48" O.C. IN ALTERNATING DIRECTIONS - GA. TO MATCH WALL ATTACH BRACING TO BOTTOM CHORD OR BLOCKING WITH (2) #10 x 1" SCREWS BATT INSULATION AT UNDERSIDE OF ROOF DECK AS REQUIRED - REFER TO T-24 FOR R VALUE ADD WEB JOIST STIFFENER X 12" LONG EACH JOIST PROVIDE 2X6 BLOCKING AS REQUIRED AT PARALLEL AND PERPENDICULAR TRUSS CONDITIONS WITH LUS26 EACH END TO WEB STIFFENER CEILING PER PLAN - REFER TO I103 FOR CEILING TYPE AND HEIGHT. 5/8" TYPE 'X' GYP. BD. 6" M A X . TYP.45° ICC-ESR #2054 LARR # 25631 FLOOR FINISH PER PLAN EXISTING TOP OF SLABI501 6 12 ' - 0 " M A X . I501 8 FINISH FLOOR 5/8" TYPE 'X' GYP. BD. CONTINUES 12" ABOVE ACOUS. CEILING SEE PLAN FOR STUD SIZE AND TRACK - ICC-ESR #2054 5/8" WATER RESISTANT GYP. BOARD (E) DEMISING WALL EXISTING CONCRETE SLAB TYPICAL INTERIOR WALL ASSEMBLY WALL & CEILING ASSEMBLY NOTES 1. ALL INTERIOR WALLS TO HAVE GYPSUM BOARD EXTEND TO PROVIDE TIGHT BUTT JOINT TO FLOOR SLAB. NO GAP IN EXCESS OF 1/4" WILL BE ALLOWED. 2. PROVIDE WATER RESISTANT GYPSUM BOARD AT THE INTERIORS OF ALL TOILET ROOMS. 3. USE 5/8" THICK GYPSUM BOARD THROUGHOUT EITHER TYPE "X" OR UN-RATED AS NOTED ON SHEET 4. PROVIDE SOUND BATT INSULATION OVER ALL OFFICE AREAS & RESTROOMS. 25 GAUGE FLOOR TRACK ANCHOR W/ 5/32" SHOT PINS AT 36" ON CENTER ATTACH BRACING TO CONTINUOUS TOP TRACK WITH (2) #10 S.M.S. 3 5/8" METAL STUD WALL BRACING AT 45 DEG. SPACED AT 48" O.C. IN ALTERNATING DIRECTIONS, SAME STUD GAUGE AS WALL PROVIDE 2X6 BLOCKING AS REQUIRED AT PARALLEL AND PERPENDICULAR TRUSS CONDITIONS W/LUS26 EA. END TO WEB STIFFENER ATTACH BRACING TO BOTTOM CHORD OR BLOCKING WITH (2) #10 x 1" SCREWS ADD WEB JOIST STIFFENER X 12" LONG EACH JOIST REFER TO PLAN A101 AND METAL STUD TABLE - SEE 5/I500 (E) GYP BD CEILING I501 6 FINISH FLOOR 5/8" TYPE 'X' GYP. BD. CONTINUES 12" ABOVE ACOUS. CEILING SEE PLAN FOR STUD SIZE AND TRACK - ICC-ESR #2054 5/8" WATER RESISTANT GYP. BOARD (E) DEMISING WALL EXISTING CONCRETE SLAB TYPICAL INTERIOR WALL ASSEMBLY WALL & CEILING ASSEMBLY NOTES 1. ALL INTERIOR WALLS TO HAVE GYPSUM BOARD EXTEND TO PROVIDE TIGHT BUTT JOINT TO FLOOR SLAB. NO GAP IN EXCESS OF 1/4" WILL BE ALLOWED. 2. PROVIDE WATER RESISTANT GYPSUM BOARD AT THE INTERIORS OF ALL TOILET ROOMS. 3. USE 5/8" THICK GYPSUM BOARD THROUGHOUT EITHER TYPE "X" OR UN-RATED AS NOTED ON SHEET 4. PROVIDE SOUND BATT INSULATION OVER ALL OFFICE AREAS & RESTROOMS. 25 GAUGE FLOOR TRACK ANCHOR W/ 5/32" SHOT PINS AT 36" ON CENTER PROVIDE 2X6 BLOCKING AS REQUIRED AT PARALLEL AND PERPENDICULAR TRUSS CONDITIONS W/LUS26 EA. END TO WEB STIFFENER ATTACH BRACING TO BOTTOM CHORD OR BLOCKING WITH (2) #10 x 1" SCREWS ADD WEB JOIST STIFFENER X 12" LONG EACH JOIST REFER TO PLAN A101 AND METAL STUD TABLE - SEE 5/I500 (E) GYP BD CEILING I501 6 2 PROVIDE 1X NAILER AS NEEDED 5 PROVIDE SEALANT AND BACKER ROD (CONT.) 1 2 3 4 5 5 4 5/8" GWB FINISHED PER SCHEDULES 6 3 STOREFRONT HEAD. USE BLACK ADONIZED MULLION. 7 1 PATCH AND REPAIR STUCCO EXTERIOR PLASTER OVER METAL LATHE. 6 CONT. VAPOR BARRIER. PATCH AND REPAIR AS NEEDED. 7 EXISTING R-19 BATT INSULATION 8 20GA GALVANIZED DRIP EDGE 8 2 PROVIDE 1X NAILER AS NEEDED 4 5/8" GWB FINISHED PER SCHEDULES 5 PROVIDE SEALANT AND BACKER ROD (CONT.) 1 2 3 4 5 5 3 STOREFRONT JAMB. USE BLACK ANODIZED MULLIONS 6 7 1 PATCH AND REPAIR STUCCO EXTERIOR PLASTER OVER METAL LATHE. 6 CONT. VAPOR BARRIER. PATCH AND REPAIR AS NEEDED. 7 EXISTING R-19 BATT INSULATION 1 2 3 4 1 PATCH AND REPAIR STUCCO EXTERIOR PLASTER OVER METAL LATHE. 2 PROVIDE 1X NAILER AS NEEDED 4 5/8" GWB FINISHED PER SCHEDULES 5 PROVIDE SEALANT AND BACKER ROD (CONT.) 3 DRIVE-THRU WINDOW SILL. USE BLACK ADONIZED MULLION. 6 CONT. VAPOR BARRIER. PATCH AND REPAIR AS NEEDED. 5 7 EXISTING R-19 BATT INSULATION 6 7 8 20GA GALVANIZED DRIP EDGE 8 WOOD BLOCKING BETWEEN ROOF TRUSSES/JOISTS AS REQUIRED ROOF FRAMING OR OTHER STRUCTURAL MEMBER SIMPSON TIE HANGER LU FRAMING ANCHOR @ EA END. USE (3) 8-d NAILS, TYP WEB FILLER WHEN APPLICABLE COMPRESSION STRUT TOP CLIP MECHANICALLY FASTENED W/(2) #8 WOOD SCREWS SUSPENDED CEILING 12GA HANGING WIRE MIN. 3" EYE LAG SCREW, TYP. SPRING CLIP 3" = 1'-0"1FIXTURE BRACING 12" = 1'-0"2SUSPENDED CEILING DETAIL 12" = 1'-0"4COMPRESSION STRUT 1 1/2" = 1'-0"3T-BAR CEILING 12" = 1'-0"5METAL STUD WALL TABLE 1 1/2" = 1'-0"6BOTTOM TRACK DETAIL 1 1/2" = 1'-0"7TOP TRACK DETAIL 1 1/2" = 1'-0"8TOP TRACK DETAIL 3/8" = 1'-0"9FULL HEIGHT WALL STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 5 / 2 0 2 4 1 0 : 2 2 : 5 1 A M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I501 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES INTERIOR DETAILS 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 3/8" = 1'-0"13TYPICAL INTERIOR WALL3/8" = 1'-0"16TYPICAL INTERIOR FURRED WALL AND CEILING FRAMING 3/8" = 1'-0"19TYPICAL INTERIOR FURRED WALL AND CEILING FRAMING - 2 3" = 1'-0"15STOREFRONT HEAD DETAIL 3" = 1'-0"12STOREFRONT JAMB DETAIL 3" = 1'-0"11STOREFRONT SILL DETAIL Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments 1 1/2" = 1'-0"20T-BAR HANGING WIRE/ COMPRESSION POST TO STRUCTURE CONNECTION DETAIL A A A A A A A 2301 N Tustin Ave #A8/22/2024 CONT. 3 5/8" MTL STUD 20GA (2) #10 SMS @ 24" O.C.(4) #10 SMS @ EA CONNECTION, TYP. GYP.BD CEILING HEIGHT PER SHEET I103 (3) #10 SMS @ EA CONNECTION, TYP. 3 5/8" 20 GA ALT. BRACING MTL STUD @ 48" O.C. EXISTING STRUCTURE ZINTRA ACOUSTICAL BAFFLES PER SHEET I103 EXISTING STRUCTURE HEIGHT GYP.BD CEILING HEIGHT PER SHEET I103 CONT. 3 5/8" MTL STUD 20GA EXISTING STOREFRONT TO REMAIN (E) STOREFRONT @ 8'-11" AFF(V.I.F) EXISTING WALL (3) #10 SMS @ EA CONNECTION, TYP. EXISTING ROOF & ROOF STRUCTURE TO REMAIN SIMPSON TIE HANGER WOOD BLOCKING 12 GA WIRE HANGER ZINTRA ACOUSTICAL BAFFLES (4) #10 SMS @ EA CONNECTION, TYP. ALIGN FACE OF FINISH (3) #10 SMS @ EA CONNECTION, TYP. 3 5/8" MTL STUD 20GA @ 16" O.C. DRYWALL SCREW (2) #10 SMS @ 16" O.C. CONTINUOUS LED STRIP LIGHT (4) #10 SMS @ EA CONNECTION, TYP. 3 5/8" 20 GA MTL TRACK (CONT.) 3 5/8" 20 GA MTL STUD 20GA @ 16" O.C. 6" 3 5/8" MTL STUD 20GA @ 16" O.C. (4) #10 SMS EA. CONNECTION, TYP. 3 5/8" MTL STUD 20GA @ 16" O.C. (2) #10 SMS @ EA CONNECTION, TYP. 3 5/8" MTL STUD 20GA @ 16" O.C. DRYWALL SCREW (4) #10 SMS @ EA CONNECTION, TYP. CONT. 3 5/8" MTL STUD 20GA ZINTRA ACOUSTICAL BAFFLE ACOUSTICAL BAFFLE TRACK 4" 4" 6" CONTINUOUS LED STRIP LIGHT GYP.BD CEILING HEIGHT PER SHEET I103 GYP.BD CEILING HEIGHT PER SHEET I103 ZINTRA ACOUSTICAL BAFFLES PER SHEET I103 12 GA WIRE HANGER, TYP. CONT. 6" MTL STUD 20GA ALTERNATING BRACING STUD 3 5/8" 20GA @ 48" O.C. TYP. 6FT MAX SPAN 6FT MAX SPAN (3) #10 SMS @ EA CONNECTION, TYP. SIMPSON TIE HANGER LU FRAMING ANCHOR @EA END. USE (3) 8-D NAILS, TYP. 6" MTL STUD 20GA @ 16" O.C. 6" MTL STUD 20GA @ 16" O.C. CONT. 3 5/8" MTL STUD 20GA 4X WOOD BLOCKING, TYP. I501 7 STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 8 / 2 0 2 4 2 : 4 0 : 2 1 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I501A 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES INTERIOR DETAILS 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 1 1/2" = 1'-0"3SOFFIT FRAMING DETAIL B NOT USED NOT USED NOT USED NOT USED 1 1/2" = 1'-0"1SOFFIT FRAMING DETAIL A Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments A A A A 2301 N Tustin Ave #A8/22/2024 4 1/2"4' - 0 1/2"4' - 0 1/2"4 1/2" 8" ARMSTRONG 15/16" T GRID 360 POLYBAKED BLACK 48"X48" GRID PATTERN, UNO AIRCRAFT STEEL CABLES (TYP.) 8" ZINTRA FELT BAFFLES TWO 8'-10" AND ONE 3'-1" EXISTING ROOF JOIST VIF I501B 15 Sim I501B 16 Sim ARMSTRONG 15/16" T GRID 360 POLYBAKED BLACK 48"X48" GRID PATTERN, UNO AIRCRAFT STEEL CABLES (TYP.) BAFFLES SLOT ON TO GRID EXISTING ROOF JOIST VIF 10'-6 1/2" AFF B/O BAFFLES1' - 0" TYP. 8" ( T Y P . ) 1 1 / 2 " 6 1 / 2 " 8" ZINTRA FELT BAFFLES TWO 8'-10" AND ONE 3'-1" (TYP.) EQ 1"EQ ARMSTRONG 15/16" T GRID 360 POLYBAKED BLACK 48"X48" GRID PATTERN, UNO AIRCRAFT STEEL CABLES (TYP.) BAFFLES SLOT ON TO GRID 8" ZINTRA FELT BAFFLES TWO 8'-10" AND ONE 3'-1" (TYP.) 8" ( B A F F L E S T Y P . ) I501B 16 Sim ARMSTRONG 15/16" T GRID 360 POLYBAKED BLACK 48"X48" GRID PATTERN, UNO AIRCRAFT STEEL CABLES (TYP.) BAFFLES SLOT ON TO GRID 8" ZINTRA FELT BAFFLES TWO 8'-10" AND ONE 3'-1" (TYP.) 1"1/2" (TYP.) 1 1/2" 0' - 1 1 / 2 " (T Y P . ) 0' - 0 1 / 4 " SUPPORT GRID 4 1/2" SUPPORT GRID 4' - 0 1/2" SUPPORT GRID 4' - 0 1/2" SUPPORT GRID 9" SUPPORT GRID 1' - 7" SUPPORT GRID 9" SUPPORT GRID 4' - 0 1/2" SUPPORT GRID 4' - 0 1/2" SUPPORT GRID 4 1/2" SU P P O R T G R I D 5" SU P P O R T G R I D 3' - 0 " SU P P O R T G R I D 1' - 7 " SU P P O R T G R I D 3' - 0 " SU P P O R T G R I D 1' - 7 " SU P P O R T G R I D 3' - 0 " SU P P O R T G R I D 7" ARMSTRONG 15/16" DRID 360 POLYBAKED TRAVERTINE DARK, (TYP.) 13 I501B Sim 14 I501B Sim I501 2 Sim LATERAL BRACING LATERAL BRACING LATERAL BRACING LATERAL BRACING LATERAL BRACING LATERAL BRACING TYP. BAFFLE LENGHT 8' - 10" BAFFLE LENGHT 2' - 4" BAFFLE LENGHT 8' - 10" TY P . S P A C I N G 8 1 / 2 " 1' - 9 " 1' - 9 " STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 8 / 2 0 2 4 2 : 4 0 : 2 3 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I501B 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES INTERIOR DETAILS 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 3/4" = 1'-0"13ZINTRA BAFFLES CROSS SECTION A 3/4" = 1'-0"14ZINTRA BAFFLES CROSS SECTION B 3" = 1'-0"15ENLAGED BAFFLES SEAM DETAIL 3" = 1'-0"20FELT PANEL - CONNECTION 3" = 1'-0"16BAFFLES TO GRID INTERLOCKING 1/2" = 1'-0"2ZINTRA BAFFLES T-GRID PLAN 1/2" = 1'-0"1ENLARGED ZINTRA BAFFLES PLAN Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments A A A A A A 2301 N Tustin Ave #A8/22/2024 (2) 3 5/8 MTL STUDS WITH 5/8" GYP. BD. EACH SIDE - TYP. WATER HEATER (700 LB MAX) R.O. STORAGE TANK (350 LB MAX) (2) 1/2" PLYWOOD FLOOR OR 1/2" GLASSCRETE CEMENT BOARD (2) 6" X 16 GA. MTL JOISTS WITH 4 1/2" X 12 PANHEAD SCREWS WITH WASHERS - ALIGN JOIST WITH WATER HEATER "FEET" PLAN VIEW 1 1/2" W X 16 GA STRAP. ATTACH TO THE CFS STUD WALL W/ (2) #14 SCREWS EACH END. A A 362S162-54 MIL STUDS, ALIGNED WITH STRAP 362S162-54 MIL STUDS, ALIGNED WITH STRAP (2) 6" 18 GA. BACK-BACK JOIST @ 16" O.C. (600S137-43, 50KSI) W/ (2) ROWS #10 X 1" SCREWS AT 4" O.C. MAX. NEW WATER RESISTANT GYP. BOARD TO BE FINISHED WITH FRP NEW WALL PER SHEET A101 DETAIL A-A STOP GYP BOARD WHERE JOIST MEETS STUD WALL. STOP GYP BOARD WHERE JOIST MEETS STUD WALL. XXXT125-XX BLOCKING TO MATCH WALL DEPTH AND GA. W/ (2) #10 X 1/2" SCREWS AT STUDS. XXXT125-XX BLOCKING TO MATCH WALL DEPTH AND GA. W/ (2) #10 X 1/2" SCREWS AT STUDS. STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 8 / 2 0 2 4 2 : 4 0 : 2 3 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I501C 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES INTERIOR DETAILS 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments NOT USEDNOT USED NOT USEDNOT USEDNOT USED NOT USEDNOT USEDNOT USED NOT USEDNOT USED NOT USEDNOT USED 1/2" = 1'-0"1WATER HEATER & RO PLATFORM DETAIL NOT USED NOT USED NOT USED NOT USED A A 2301 N Tustin Ave #A8/22/2024 10"X10" (250MM X 250MM) BACKER BOARDS. ATTACH TO PLYWOOD SUBSTRATE WITH SILICONE ADHESIVE AND WOOD SCREWS. SILICONE PERIMETER. INTERIOR FACE OF DIEWALL FINISHED FLOOR PUMP ATTACHED TO BACKER BOARD WITH ASSEMBLY COMPONENTS SEE NOTES ABOVE FOR ASSEMBLY ITEMS NOTES: 1. LOCATE PUMP WITHIN CORD LENGTH LIMIT. ORIENT WITH PUMP HEAD LEFT, RIGHT AND AT BOTTOM. LOOSEN PUMP HEAD CLAMP, ROTATE AND RE-TIGHTEN AS REQUIRED PER ORIENTATION TO PROVIDE FRONT ACCESS TO FLOW. ADJUSTMENT WITHIN CORD LENGTH LIMIT. 2. USE LOCKTITE ON ISOLATOR THREADS. DO NOT OVER TIGHTEN. 3. LOOSEN PUMP HEAD CLAMP, ROTATE AND RE-TIGHTEN AS REQUIRED FOR PUMP ORIENTATION. 4. BACKER BOARD'S ASSEMBLY COMPONENTS INCLUDE: (1) BACKER BOARDS (4) TENETS, 1/4-20 VENDOR MOUNTED (8) WOOD SCREWS #8 1-1/4" (32MM) (4) NEOPRENE ISOLATORS, KARMAN RUBBER, K84-60 NEOPRENE (4) LOCK NUTS, 1/4-20 NYLON (4) WASHERS, 1/4" (7MM) FLAT MI N . 6" ( 1 5 2 M M ) DO NOT BLOCK GROMMET OPENING. CUT ANGLE AS REQUIRED TO MAINTAIN MIN. 1/2" (13MM) CLEAR AROUND OPENING. MECHANICALLY FASTEN COUNTER-SUNK CORROSION RESISTANT FASTENERS AT 6"(150MM) O.C. WITH 3/4" (19MM) EMBEDMENT. MECHANICALLY FASTEN ANGLE TO COUNTERTOP SUBSTRATE OR EPOXY FASTEN ITO COUNTERTOP.1 1/2" X 1 1/2" (38MM X 38MM) CORROSION RESISTANT STEEL ANGLE UNDERCOUNTER REFRIGERATOR . 1/2" (13MM) PREFERRED OFFSET DISTANCE FROM EDGE OF COUNTERTOP COUNTERTOP DEPTH MAY VARY COUNTERTOP ABOVE UNDERCOUNTER REFRIGERATOR STEEL ANGLE CENTERED ON REFRIGERATOR EQ . EQ . FRONT EDGE OF COUNTERTOP TO FACE OF ANGLE 2' - 5" (737MM) SECTION VIEW PLAN VIEW NOTES 1. 24" (610MM) 1 1/2" X 1 1/2" (38MM X 38MM) STEEL ANGLE TO BE USED WITH SINGLE DOOR REFRIGERATORS. 2. 48" (1220MM) 1 1/2" X 1 1/2" (38MM X 38MM) STEEL ANGLE TO BE USED WITH DOUBLE DOOR REFRIGERATORS. SE E N O T E S B E L O W FRONT EDGE OF COUNTERTOP ABOVE .3 / 4 " 6" VERIFY IN-WALL BLOCKING OR ENSURE SOLID ATTACHMENT OF CLEAT TO WALL AT EACH STUD CENTER FASTENERS VERTICALLY ON WALL CLEAT SOLIDLY ATTACHED TO WALL. SEE SCHEDULE "WALL TYPE FASTENER SCHEDULE" FOR SPECIFICATIONS. 1"X4" (25MM X 100MM) FURRING STRIP OR EQUIVALENT STUD WALL BLOCKING REQUIREMENTS: WOOD STUD WALLS REQUIRE MIN. 2" X 6" (50MM X 150MM) WOOD BLOCKING SECURED FLUSH TO STUD FACE WITH (3) 10D NAILS (OR EQUIVALENT) METAL STUD WALLS REQUIRE MIN. 2" X 6" (50MM X 150MM) WOOD BLOCKING SECURED FLUSH TO STUD FACE WITH MIN. (3) #6 CT. 1.25" (30MM) SCREWS (OR EQUIVALENT) EQ EQ EQ EQ EQ EQ EQ VARIES WALL TYPE FASTENER SCHEDULE WALL TYPE WALL BLOCKING FASTENERS NOTES WOOD FRAME #8 X3" (75MM) WD OR EQUIVALENTX REFER TO BLOCKING REQUIREMENTS METAL FRAME X #6 CT. X 1 1/4" (30MM) MTL/WD OR EQUIVALENT MIN. 5/16" X 3" (8MM X 75MM) TAPCON OR EQUIVALENT MIN. 1/4" X 3" (7MM X 75MM) SLEEVE ANCHOR OR EQUIVALENT MIN. 1/4" X 1" (7MM X 25MM) WEDGE ANCHOR OR EQUIVALENT SPACE PER DETAIL THIS SHEET SPACE PER DETAIL THIS SHEET AVOID SETTING ANCHORS IN MORTAR JOINTS SPACE PER DETAIL THIS SHEET (6) FASTENERS EVENLY SPACED 3" (75MM) MINIMUM. ACROSS OPENING (TYPICAL AT ALL CABINETS) CENTER FASTENERS VERTICALLY ON WALL CLEAT SOLIDLY ATTACHED TO WALL. SEE "WALL TYPE FASTENER SCHEDULE" FOR SPECIFICATION. ADJUSTABLE SHELF (IF APPLICABLE) METAL TRIM TO BE PAINTED SIMILAR FASTENERS AT EACH STUD LOCATION ACROSS OPENING (TYPICAL AT ALL CABINETS) CMU CONCRETE BRICK REFER TO BLOCKING REQUIREMENTS 34" MAX. AFF METAL ANGLE, TYP. COUNTERTOP SUBSTRATE ALUM. Z-CLIPS, TYP. FINISH PANEL DIEWALL COUNTERTOP LED STRIP LIGHTING VARIES MI N . 1/ 2 " 4" (TYP.) NOTE: ALL COMPONENTS FURNISHED BY OTHERS AND INSTALLED BY G.C. UNLESS NOTED OTHERWISE. 2 1 / 4 " FINISH PANEL METAL ANGLE TRIM ATTACHED AT BACK OF PANEL WITH COUNTER SUNK FASTENER GAP FOR Z-CLIP ATTACHMENT - TYP. OR BLOCKING FOR DIRECT MOUNT TO DIEWALL TY P . 1/ 4 " STEEL FLAT BAR TRIM AT BOTTOM AND TOP OF PANELS, TYP. ENCAPSULATE DIE WALL ENDS WITH PVC TO MATCH STORE SPECIFIC LAMINATE DIEWALL TYP. OR CABINET 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 4 6 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I502 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES CASEWORK DETAILS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 Revision Schedule Rev Date By Description 1 1/2" = 1'-0"1ESPRESSO PUMP MOUNTED AT DIE WALL 1 1/2" = 1'-0"3UNDERCOUNTER REFRIGERATOR STOP INSTALLATION 1" = 1'-0"5UPPER CABINET ATTACHMENT 6" = 1'-0"15FINISH PANEL - BUILT-UP COUNTERTOP OVERHANG 12" = 1'-0"6TYPICAL DETAIL AT FINISH PANEL END - VERTICAL METAL TRIM NOT USEDNOT USED NOT USEDNOT USED STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 CORIAN SHROUD COVE DETAIL ON THIS SIDE ONLY 'U' SHAPED ALUMINUM GLAZING SEAT SECURE TO BLOCKING BELOW BLOCKING MIN. 1/16" GAP AT GLASS FILLED WITH CLEAR SILICONE, BOTH SIDES, TYP. VERIFY MIN. GLASS HEIGHT WITH LOCAL CODES 34" MAX. A.F.F. 1 1/2" 3/8" TEMPERED GLASS 6" 4" NOTE: ALL COMPONENTS FURNISHED BY OTHERS AND INSTALLED BY G.C. UNLESS NOTED OTHERWISE. ESPRESSO CAP CORIAN COUNTERTOP METAL BOTTOM TRIM PER DETAILS METAL CORNER TRIM PER DETAILS HARDWOOD SLATS 1/2" PLYWOOD BACKER (TYP.) HARDWOOD SLATS SECURED TO SUBSTRATE / STRUCTURE PER MANUFACTURER'S RECOMMENDATIONS CUSTOMER FACING SIDE INTERIOR SIDE ELEVATION .3/ 8 " ...2 5/8" 1/8" 2 1/4" .3/ 1 6 " . 3/ 1 6 " 20 STAVES, NO BUTT JOINTS 3' - 11 3/4" 3' - 11 1/2" BACKER 2' - 3 " A NOT TO SCALE ENLARGED SECTION PROFILEA DIRECTION OF GRAIN. TYP. ALL SLATS. INTERIOR SIDE TO BE SECURED TO SUBSTRATE / STRUCTURE PER DETAILS 2' - 6 " M I N . 2' - 8 " 2' - 0 " 2' - 1 0 " 10 ' - 0 " M I N . C E I L I N G H E I G H T PROVIDE SPLIT ESCUTCHEON PLATE AT WALL PENETRATION DOOR FACE W/ TAPERED EDGE PULL MOUNTING TEMPLATE, BLACK IN-WALL BLOCKING REQUIRED, PROVIDED BY G.C. FRAMING, BEYOND LIGHTING COVE DOOR FACE W/ TAPERED EDGE PULL MOUNTING TEMPLATE, BLACK IN-WALL BLOCKING REQUIRED, PROVIDED BY G.C. DOOR FACE W/ TAPERED EDGE PULL MOUNTING TEMPLATE, BLACK IN-WALL BLOCKING REQUIRED, PROVIDED BY G.C. SECTION A - FUTURE DISPENSESECTION B - CUP LABELER BA FRAMING, BLACK LIGHTING COVE SECTION C - NUGGET ICE DISPENSESECTION D - DMB D C CL E A R 18 " M I N . ACCESS DOOR CEILING SOFFITUNDER SOFFIT LIGHTING UNDER CABINET STRIP LIGHTING UNDER CABINET STRIP LIGHTING UNDER CABINET STRIP LIGHTING ELEVATION DMB EQ EQ NOTE: • CEILING HEIGHT 10'-0" MIN. 1. NUGGET ICE RIDE SYSTEM TO RUN IN STANDARD SOFFIT 2. DMB TO BE MOUNTED ON FACE OF SOFFIT • ACCESS PANEL TO BE SIZED TO AVOID CONFLICT WITH LIGHTING COVE • PROVIDE CONTINUOUS FLOOR TO CEILING BLOCKING FOR THE ENTIRE LENGTH OF THE STATION 1' - 2 " 3' - 1 0 " FRP TO FINISH INTERIOR OF SOFFIT. FRP ON BACK WALL EXTENDS TO BOTTOM OF UPPER CABINET (ABOVE ICE DISPENSE ONLY) OPENING IN SOFFIT TO ACCESS EQUIP. BELOW 1" MIN. 24" MIN. 18 " M I N . EXTEND FULL HEIGHT BLOCKING 8" MIN. BEYOND STATION . TERMINATE AT OH SOFFIT 4' - 7" CLEAR 18" MIN. ACCESS DOOR NOTES: CABINETS TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS 2' - 1 0 " 2' - 2 " ELECTRICAL OUTLET 2X6 SUPPORT W/SHIM COVED BASE PER SHEET I104 2'-10" AFF (BACKBAR COUNTERTOP) COUNTERTOP WITH INTEGRAL BACKSPLASH 1/4" GREEN BOARD TILE SUBSTRATE BY GC BACKBAR WALL TILE BETWEEN TOP OF BACKSPLASH AND CEILING ABOVE - SEE INTERIOR ELEVATIONS 1 1'-7" AFF (CW SUPPLY) 2 1'-6" AFF (CWF SUPPLY) 3 1'-5" AFF (HW SUPPLY) 4 VARIES: 1/4" PER FT. FALL (ABS 2" WASTE LINE) 5 APPLY FRP TO WALL BEHIND CABINETS -SEE I105 WALL FINISH PLAN. 5" * 45 LBS DEAD LOAD FOR LIQUID STORAGE OVER AND ABOVE THE CASEWORK ITSELF. * A LIVE LOAD OF A PARTNER EITHER PULLING AND OR CLIMBING ON THE CASEWORK. * SEISMIC ACCELERATION CONDITIONS AT THE SITE. 1 2 3 4 5 STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 5 / 2 0 2 4 1 0 : 2 2 : 5 6 A M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I502A 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES CASEWORK DETAILS 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 6" = 1'-0"1ESP SHROUD - CORIAN WITH SNEEZE GUARD3/4" = 1'-0"9FINISH APPLICATION (MAD 101-V) SLAT W/ REVEAL 3/4" = 1'-0"3UPPER CABINET -CEILING HEIGHT GREATER THAN 10'-0" -WITH SOFFIT 1" = 1'-0"17WALL SECTION @ BACKBAR (SHELVING) Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments A 2301 N Tustin Ave #A8/22/2024 FOR OPENING SIZE/ SHAPE VARIES. SEE PLAN VIEW 13 mm 1/2" FULLY ENCAPSULATED MOISTURE RESISTANT SUBSTRATE COMMERCIAL GRADE SILICONE AT EXPANSION JOINT 3 mm 1/8" 32 m m 1 1 / 4 " 12 7 m m VE R I F Y H T . P E R C O N S T R U C T I O N D R A W I N G S MI N . 5 " 10 mmr 3/8" 3 mmr 1/8" 25 mm 1" STANDARD GROMMET HOLE 4" / 75 mm TYP. 51 mm 2" TYP. 3 mm 1/8" 13 mm 1/2" 15 2 m m 6" 1/2" (13mm) X 1/2" SCRIBE WALL FULLY ENCAPSULATED MOISTURE RESISTANT SUBSTRATE COMMERCIAL GRADE SILICONE AT EXPANSION JOINT GROMMET INSERT SHOWN DASHED 12 7 m m VE R I F Y H T . P E R C O N S T R U C T I O N D R A W I N G S MI N . 5 " 3 mmr 1/8" FULLY ENCAPSULATED MOISTURE RESISTANT SUBSTRATE 25 mm 1" 1/2" (13mm) X 1/2" SCRIBE WALL RAISED GROMMET HOLE 4" / 75 mm TYP. 51 mm 2" TYP. COMMERCIAL GRADE SILICONE AT EXPANSION JOINT 15 2 m m 6"GROMMET INSERT SHOWN DASHED 32 m m 1 1 / 4 " 13 m m 1/ 2 " 32 mm TO C.L. 1 1/4" 3 mmr 1/8" FULLY ENCAPSULATED MOISTURE RESISTANT SUBSTRATE COMMERCIAL GRADE SILICONE DRIP CHANNEL IF NEEDED PER WORKSTATION 13 mm 1/2"3 mm 1/8" 6 mmr 1/4" 5 m m 3/ 1 6 " EQUIPMENT INSERT VARIES PER 13 mm 1/2" FULLY ENCAPSULATED MOISTURE RESISTANT SUBSTRATE COMMERCIAL GRADE SILICONE AT EXPANSION JOINT 3 mm 1/8" 41 m m 1 5 / 8 " 3 m m 1/ 8 " 2 mmr 1/8" 13 mm 1/2" COMMERCIAL GRADE SILICONE AT FIXTURE AND COUNTERTOP CONNECTION -TYP. FULLY ENCAPSULATED MOISTURE RESISTANT SUBSTRATE PER EQUIP. VARIES 10 m m 3/ 8 " 3 m m 1/ 8 " COMMERCIAL GRADE SILICONE AT EXPANSION JOINT 10 mm R 3/8" 41 m m 1 5 / 8 " 3 mm 1/8" EQUIPMENT INSERT VARIES PER 13 mm 1/2" 3 mm TYP. 1/8" MAX. COMMERCIAL GRADE SILICONE AT FIXTURE AND COUNTERTOP CONNECTION -TYP. 1 1/2" MIN. PER SHOP DRAWINGS TYP. LENGTH BY MFR.3 mm TYP. 1/8" COMMERCIAL GRADE SILICONE AT EXPANSION JOINT 1/2" CORIAN - TYP FULLY ENCAPSULATED MOISTURE RESISTANT SUBSTRATE REINFORCEMENT STRIP - CORIAN R .25" 0.19" DEEP FULLY ENCAPSULATED MOISTURE RESISTANT SUBSTRATE COMMERCIAL GRADE SILICONE AT EXPANSION JOINT DRIP CHANNEL 6 mm 1/4" r 1/4" 12 mm 1/2" 25 mm 1" 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 4 8 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I502B 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES CASEWORK DETAILS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 Revision Schedule Rev Date By Description 12" = 1'-0"1CORIAN COUNTERTOP TYP. CUTOUT AT TRASH AND GROMMET 12" = 1'-0"3CORIAN COUNTERTOP BACKSPLASH AND GROMMET12" = 1'-0"11CORIAN COUNTERTOP BACKSPLASH AND COVED GROMMET 12" = 1'-0"2CORIAN COUNTERTOP FRONT EDGE 12" = 1'-0"9CORIAN COUNTERTOP TYP. ICE BIN CUTOUT WITH W/ SQUARED EDGE 12" = 1'-0"10CORIAN COUNTERTOP TYP. SINK CUTOUT W/ COVED EDGE 12" = 1'-0"17CORIAN COUNTERTOP REINFORCEMENT STRIP AT HARD SEAM 12" = 1'-0"18CORIAN COUNTERTOP FRONT EDGE AT ICE BIN NOT USED NOT USED STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 STL. FLAT BAR VERTICAL TRIM AT PLANK END TO FORM MITERED CORNER DETAIL GAP FOR Z-CLIP ATTACHMENT - TYP. OR BLOCKING FOR DIRECT MOUNT TO DIEWALL DIEWALL - TYP., OR CABINET FASTEN MTL. TRIM TO FINISH PANEL FROM SIDE WITH COUNTER SUNK FASTENER FINISH PANEL TYP. 1/4" A-A ELEVATION VIEW A-A SECTION VIEW EQ EQ 1' - 4 " 1' - 4 " TOP OF MERCHANDISE DISPLAY FIXTURE 5'-11 1/2" (1816MM) A.F.F. (VERIFY IN FIELD) "L" BRACKET PROVIDED BY MANUFACTURER TO BE SECURED TO TOP OF MERCHANDISE DISPLAY USE #8 SCREW (MIN. 1 1/2" (40MM EMBEDMENT) TO SECURE BRACKET TO BLOCKING MERCHANDISE DISPLAY FIXTURE 3/4" (20MM) BLOCKING LOCATED BEHIND SUBSTRATE. EXTEND 8" (205MM) MIN. BEYOND "L" BRACKET ON ALL SIDES. 8"VARIES 8" WALL FINISH PER SCHEDULE 1' - 9 1/2"4' - 2 3/4"4' - 2 3/4"1' - 8 3/4" 1' - 9 1 / 2 " 4' - 2 3 / 4 " 4' - 2 3 / 4 " 1' - 8 3 / 4 " I502C 14 13 CTK0001CTK0001CTKX001 CTK0001 CTK0001 F-0243F-0243F-0243 F-0243 F-0243 r 1' - 8 3/4" r 1' - 8 3/4" 1' - 4 1/2"8"1' - 4 1/4"8"3' - 6 3/4"8"2' - 4 1/4"8"5" 5' - 8 1/2"3"3' - 11 3/4"3"1' - 6 1/4" 1' - 4 3/4"2"1' - 11 1/2"2"1' - 11 1/2"2"1' - 11 1/2"2"1' - 11 1/2"2"1' - 6 1/4" 2" 9 1 / 2 " 3 1 / 4 " ø 4 3/4" 1' - 4 " 2' - 2 1 / 4 " 1" MT0028 TYP. WD0073 F-0243F-0243 1' - 4 1/2"2"1' - 11 1/2"2"1' - 11 1/2"2"1' - 11 1/2"2"1' - 11 1/2"2"1' - 6 1/4" 4 1/2"8"2' - 5"8"3' - 6 3/4"8"1' - 4 1/4"8"1' - 4 1/2" 1' - 6 1/2"3"3' - 11 3/4"3"5' - 8 1/2" 1' - 4 " 1" 2' - 2 1 / 4 " ø 4 3/4" 2" 9 1 / 2 " 3 1 / 4 " MT0028 TYP. F-0243F-0243 WD0073 1" MT0029 STEEL ANGLE TOP & BOTTOM TO CAP WOOD CLADDING CEILING WALL AS SCHEDULED PROVIDE BLOCKING AS REQUIRED 1/ 8 " WOOD CLADDING AS SCHEDULED PAINT BLACK 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 4 9 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I502C 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES CASEWORK DETAILS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 Revision Schedule Rev Date By Description 12" = 1'-0"1MITER DETAIL AT VERTICAL CORNER TRIM 3/4" = 1'-0"3MERCHANDISE WALL BAY DISPLAY FIXTURE WALL ATTACHMENT NOT USED 3/4" = 1'-0"11ENLARGED BANQUETTE 3/4" = 1'-0"14BANQUETTE ELEVATION A 3/4" = 1'-0"13BANQUETTE ELEVATION B 6" = 1'-0"9CLADDING TOP DETAIL STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 6" (150MM) +/- TYP. A.F.F. CONTINUOUS WATERPROOF MEMBRANE. EXTEND 6" (150mm) UP BASE COVED TILE BASE PER SCHEDULE. ADHERE TO TOE KICK BASE PER MFR'S RECOMMENDATIONS. 3/8" (6MM) RADIUS AT COVED BASE FINISH FLOOR PER SCHEDULE CONTINUOUS WATERPROOF MEMBRANE APPLIED TO SUBFLOOR. EXTEND EDGE TO 12" (305mm) OFFSET FROM CABINET BASE. CONCRETE SLAB SEALANT TO MATCH ADJACENT WALL FINISH COVED TILE BASE PER SCHEDULE. ADHERE TO WALL PER MFR'S RECOMMENDATIONS. 3/8" (6MM) RADIUS AT COVED BASE FINISH FLOOR PER SCHEDULE CONCRETE SLAB WALL TYPE PER LEGEND STOREFRONT DOOR WITH THRESHOLD WALK-OFF MAT PER SCHEDULE STAINLESS STEEL ANGLE TILE FLOOR PER SCHEDULE PER TILE MFR. WATERPROOF MEMBRANE ON WOOD SUBFLOOR ONLY . ECO-GRIP BASE CAP. COLOR TO MATCH ECO-GRIP FLOORING ECO-GRIP EPOXY ADHESIVE ECO-GRIP SEALANT ECO-GRIP FLOORING 3/8" (6MM) ROUTED COVE STAINLESS STAPLE OR POWDER COATED FASTENER FRP WALL COVERINGWALL AND SHEATHING PER PLAN CONCRETE SLAB ECO-GRIP FLOORING ECO-GRIP EPOXY ADHESIVE 16 GA. 2 1/4" (57MM) WIDE STAINLESS STEEL TRANSITION STRIP TILE FLOOR PER PLAN SUBSTRATE MAY REQUIRE SLOPING TO ADJUST HEIGHT SO THAT ECO-GRIP AND ADJACENT FLOOR ARE FLUSH STAINLESS FASTENER LEAD ANCHOR ECO-GRIP SEALANT ROUTE OUT FLOORING TO DEPTH OF TRANSITION STRIPCONCRETE SLAB SEALANT SLOPE 2% MAX ECO-GRIP FLOORING ECO-GRIP SEALANT ECO-GRIP BASE CAP. COLOR TO MATCH ECO-GRIP FLOORING STAINLESS STAPLE OR POWDER COATED FASTENER CABINET FINISH FACE INSTALL CASEWORK BASE PRIOR TO ECO-GRIP FLOORING ECO-GRIP EPOXY ADHESIVE 3/8" (6MM) ROUTED COVE CONCRETE SLAB 6" ( 1 5 0 M M ) M I N . ECO-GRIP FLOORINGECO-GRIP EPOXY ADHESIVE 3/8" (6MM) ROUTED COVE INSTALL CASEWORK BASE PRIOR TO ECO-GRIP FLOORING 6" (150MM) +/- TYP. A.F.F. CABINET TOE-KICK OVERHANG CONCRETE SLAB ECO-GRIP BASE CAP. COLOR TO MATCH ECO-GRIP FLOORING STAINLESS STAPLE OR POWDER COATED FASTENER ECO-GRIP SEALANT ECO-GRIP FLOORING ECO-GRIP SEALANT ECO-GRIP BASE CAP. COLOR TO MATCH ECO-GRIP FLOORING STAINLESS STAPLE OR POWDER COATED STEEL FASTENER BAR DIEWALL INSTALL CASEWORK DIEWALL PRIOR TO ECO-GRIP FLOORING ECO-GRIP EPOXY ADHESIVE 3/8" (6MM) ROUTED COVE BASE AND FLOORING PER SCHEDULE BAR FINISH PANEL CONCRETE SLAB 6" ( 1 5 0 M M ) M I N . CAFE BAR CONCRETE SLAB FLOOR SINK HALF GRATE STAINLESS STEEL MEMBRANE CLAMP ECO-GRIP EPOXY ADHESIVE ECO-GRIP FLOORING STAINLESS STEEL SEDIMENT BUCKET WITH LASER PERFORATIONS ECO-GRIP BASE CAP. COLOR TO MATCH ECO- GRIP FLOORING ECO-GRIP EPOXY ADHESIVE ECO-GRIP SEALANT ECO-GRIP FLOORING 3/8" ROUTED COVE STAINLESS STAPLE OR POWDER COATED FASTENER FRP WALL COVERING CONCRETE CURB 10 " 6" ECO-GRIP FLOORING 3/8" ROUTED COVE WALL TILE PER SCHEDULE CLEAR SEALANT STAINLESS STEEL BACKSPLASH CEMENTITOUS BACKER BOARD WALL TYPE PER LEGEND SCHLUTER-JOLLY EMBEDDED IN GROUT WALL TILE PER SCHEDULE CLEAR SEALANT SOLID SURFACE BACKSPLASH CEMENTITOUS BACKER BOARD HEIGHT PER PLAN WALL TYPE PER LEGEND SCHLUTER-JOLLY EMBEDDED IN GROUT STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 5 / 2 0 2 4 1 0 : 2 2 : 5 9 A M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I503 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES FLOOR AND WALL FINISH DETAILS 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 6" = 1'-0"17INTEGRAL TILE BASE AT CABINET 6" = 1'-0"8INTEGRAL TILE BASE AT WALL 6" = 1'-0"14TRANSITION - TILE TO WALK OFF MAT 6" = 1'-0"2ECO-GRIP BASE CAP WITH FRP 12" = 1'-0"1ECO-GRIP TO TILE TRANSITION AT FOOT TRAFFIC AREA 6" = 1'-0"6ECO-GRIP BASE AT CABINET SIDE 6" = 1'-0"4ECO-GRIP BASE AT CABINET FRONT 6" = 1'-0"10ECO-GRIP BASE AT BAR DIEWALL 6" = 1'-0"9ECO-GRIP CLAMPING FLOOR SINK FLOOR FINISH DETAIL 3" = 1'-0"11ECO-GRIP BASE CAP AT MOP SINK CURB6" = 1'-0"20SST BACKSPLASH TO TILE TRANSITION 6" = 1'-0"16SS BACKSPLASH TO TILE TRANSITION Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments A 2301 N Tustin Ave #A8/22/2024 MI N . B L O C K I N G ( V I F ) 3' - 1 1 / 4 " ( 9 2 0 M M ) (2 3 0 M M ) 6" CENTER OF MENU BOARDS AT 7' - 4" (2235MM) A.F.F. MIN., 8' - 6" (2590MM) A.F.F. MAX. SEE INTERIOR ELEVATIONS FOR ACTUAL DIMENSION 3/4" PLYWOOD BACKING BEHIND WALL FINISH, SECURED TO STRUCTURE METAL RECESSED CABLE MANAGEMENT AND POWER STORAGE BOX. MINIMUM (1) RECEPTACLES AND (1) DATA PORT PER SCREEN. MINIMUM (4) OUTLETS AND (4) DATA PORTS PER STORE. CENTER OF MENU ASSEMBLY 3' - 8 1/4"3' - 8 1/4" 4"4"4"4"6"6"4"4" 2' - 9"2' - 9" MIN. OFFSET (TYP.) 6"WALL MOUNTED MENU BOARD BRACKET DIGITAL SCREEN EQ EQ EQ.11' - 0 1/2" (3364.2MM 3 SCREENS)EQ. 12' - 0 1/2" (3670.3 MM MIN. BLOCKING (VIF)) MI N . O F F S E T ( T Y P . ) 6" MAX. LENGTH DATA (5'-6") MAX. LENGTH POWER (5'-6") r 5' - 6" r 5' - 6" EDGE OF DIGITAL SCREEN WALL MOUNTED ORDER STATUS BOARD MOUNTING BRACKET SEE INTERIOR ELEVATIONS FOR ACTUAL DIMENSION 3/4" PLYWOOD BACKING BEHIND WALL FINISH, SECURED TO STRUCTURE METAL RECESSED CABLE MANAGEMENT AND POWER STORAGE BOX. MINIMUM (1) RECEPTACLES AND (1) DATA PORT PER SCREEN. 2' - 1 0 1 / 4 " 6" 3' - 8 1 / 2 " 6" 6"2' - 2"6" 4' - 8 1 / 2 " M I N . B L O C K I N G ( V I F ) 3' - 2" MIN. BLOCKING (VIF) DELL WYSE AND POWER BRICK SECURED TO MOUNTING BRACKET DEVICE CAGE TOP OF ORDER STATUS BOARD FOR UNOBSTRUCTED VIEW PLACEMENT 8' - 9" (2670MM) A.F.F. MAX. 7' - 6" (2290MM) A.F.F. PREFERRED 6' - 6" (1980MM) A.F.F MINIMUM TOP OF ORDER STATUS BOARD FOR ABOVE BAR COUNTERTOP PLACEMENT 8' - 9" (2670MM) A.F.F. MAX. 8' - 4" (2540MM) A.F.F. PREFERRED 7' - 6" (2290MM) A.F.F MINIMUM EQ EQ MIN. OFFSET DISTANCE (TYP.) RECEPTACLE FOR REFRIGERATOR AND/OR FREEZER AT 84" (2135MM) AFF BACK WALL RECEPTACLE FOR SANITIZER AT 18" (460MM) A.F.F. BACK WALL MOP SINK WATER FILTRATION SYSTEM (ABOVE) GFCI 120V DUPLEX RECEPTACLE FOR BOOSTER PUMP ABOVE INSTALLED AT FACE OF WALL AT 8'-9" (2670MM) A.F.F. (915MM) 3' - 3" (75MM) 3" GFCI 120V DUPLEX RECEPTACLE FOR WATER FILTRATION SYSTEM AT 54" (1370MM) A.F.F. (305MM) 1' - 0" GFCI 120V QUAD RECEPTACLE FOR WATER FILTRATION SYSTEM AT 76" (1930MM) A.F.F. .6" (152MM) MIN. CLEAR TO BACK WALL ELEVATION - ELECTRICAL DIAGRAM PLAN - ELECTRICAL DIAGRAM ICE DIVERTER VALVE CONT. FRP ON BACK WALL OFER IN WALL BLOCKING BACK WALL ICE BIN ICE MACHINE ICE HEAD ADAPTER POWER RECEPTACLES FOR NUGGET ICE AT 72" (1920MM) A.F.F. ICE BIN SENSOR CABLE POWER CORD ICE MACHINE ICE HEAD ADAPTER BIN TOP SENSOR DISTRIBUTION UNIT ICE DIVERTER VALVE 6' - 0 " EQ EQ POWER RECEPTACLES FOR NUGGET ICE AT 72" (1920MM) A.F.F. 3" EQ EQ 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 5 2 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I504 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ELECTRICAL DETAILS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 3/4" = 1'-0"1DIGITAL MENU BOARDS - STANDARD MOUNT 3/4" = 1'-0"3ORDER STATUS BOARD INFRASTRUCTURE3/4" = 1'-0"11REFRIGERATOR/FREEZER - ELECTRICAL 3/4" = 1'-0"12SANITIZING WORKSTATION - ELECTRICAL3/4" = 1'-0"16WATER FILTRATION - CONFIGURATION III Revision Schedule Rev Date By Description 3/4" = 1'-0"13ELECTRICAL - NUGGET ICE STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 NOTE:EQUIPMENT SHOWN AS DASHED LINES IS TO BE FURNISHED AND INSTALLED BY OWNER UNLESS NOTED OTHERWISE. PLAN VIEW ELEVATION VIEW 1 380MM 1' - 3" 4' - 0 " ( 1 2 2 0 M M ) A . F . F . SECURE KEY BOX 110MM 4 1/4" CEILING HEIGHT SHOWN AT 96" (2440MM). REFER TO REFLECTED CEILING PLAN(S) FOR ACTUAL HEIGHT. LOW VOLTAGE CABLE BUNDLE 1 MUSIC SYSTEM PLAY NETWORK SPEAKERS 2" (50MM) Ø SLEEVE FOR LOW VOLTAGE CABLE BUNDLE MOUNTED TO (2) UNISTRUTS CEILING TRIM RING PRINTER ROLLING CART IPOD TOUCH CHARGING CRADLE CASH SCALE HOME PHONE CONNECT (HPC) 60" W X 70" H (1525MM W X 1780MM H) MIN. 3/4" FIRE RATED PLYWOOD BACKER BOARD. FASTEN TO STRUCTURE TO HOLD MIN. 350 PSF. PAINTABLE SURFACE ON ROOM SIDE & FINISH AS SCHEDULED. POWER, TELEPHONE & DATA RECEPTACLES AT 12" (305MM) A.F.F. TO CENTER OF GROUPING. SEE FLAN VIEW NOTE "A" ABOVE FOR DESCRIPTION. POWER & DATA RECEPTACLES AT 60" (1525MM) A.F.F. TO CENTER OF GROUPING. SEE NOTE 'B' ABOVE FOR DESCRIPTION. DESK OFFICE PC LAPTOP 25MM 1" SLEEVE FOR LOW VOLTAGE CABLE BUNDLE MOUNTED TO (2) UNISTRUTS 2 2 670MM 2' - 2 1/4" ROLLING CART SHELVING ABOVE POWER & DATA RECEPTACLES (IN WALL, AT MUSIC SYSTEM SHELF) (1) DUPLEX RECEPTACLE FOR: MUSIC SYSTEM AMPLIFIER AND FUTURE USE (1) 2-DATA PORT FOR: CURIO POWER, TELEPHONE & DATA RECEPTACLES (IN WALL, BELOW DESK) (1) QUAD RECEPTACLE FOR: PC, PRINTER, PHONE AND HPC (1) QUAD RECEPTACLE FOR: LAPTOP, CASH SCALE AND FUTURE USE (1) QUAD RECEPTACLE (1) PHONE MAIN (1) 2-DATA PORT FOR: PC AND PRINTER DESK A B WALL MOUNTED SHELVING UNIT ATTACHED TO BACKER BOARD CORDLESS 1 LINE PHONE MUSIC SYSTEM PLAYER AND AMPLIFIER (FURNISHED BY OWNER, INSTALLED WITH SPEAKER SYSTEM BY GC) ON 14" DEEP (355MM) SHELF ONLY (MIN.) 56" W X 42" H (1420MM W X 1065MM H) MIN. 3/4" FIRE RATED PLYWOOD BACKER BOARD. FASTEN TO STRUCTURE TO HOLD MIN. 350 PSF. PAINTABLE SURFACE ON ROOM SIDE AND FINISH AS SCHEDULED. MINI GROUND BAR FOR EQUIPMENT RACK. GC TO COORDINATE RACK GROUNDING TO BAR WITH #6 GROUND WIRE AND PER JURISDICTIONAL REQUIREMENTS POWER & DATA RECEPTACLES AT 87" (2210MM) A.F.F. TO CENTER OF GROUPING. SEE PLAN VIEW NOTE "A" ABOVE FOR DESCRIPTION. EQUIPMENT RACK WALL MOUNTED TO STRUCTURE BY STARBUCKS VENDOR (GC TO COORDINATE INSTALLATION). GROUND RACK PER MFR'S ASSEMBLY INSTRUCTIONS. SEE EQUIPMENT RACK SCHEDULE BELOW FOR EQUIPMENT INCLUDED WITHIN. PLAN VIEW MOUNT GROUND BAR AT 116" (2945MM) A.F.F. ELEVATION VIEW 610MM 2' - 0" CLEAR 7' - 0 " EQEQ . 65MM 2' - 2 1/2" (2) 2" (50 MM) Ø SLEEVES FOR LOW VOLTAGE CABLE BUNDLES MOUNTED TO (2) UNISTRUTS CEILING TRIM RING (TYP.) ENLARGED VIEW LAY-IN CEILING UPS IPS EQUIPMENT ROUTER EQUIPMENT RACK SCHEDULE NETWORK SWITCH PATCH PANEL SECURITY RECORDER (NVR) SECURITY KEYBOARD PRODUCTION CONTROLLER DEVICES NOTE:EQUIPMENT SHOWN AS DASHED LINES IS TO BE FURNISHED AND INSTALLED BY OWNER UNLESS NOTED OTHERWISE. MOUNT EQUIPMENT RACK AT 84" (2133MM) A.F.F. 76" (1930MM) CLEAR AREA BELOW FOR TRASH CONTAINERS, STORAGE OR DELIVERY DROP OFF WIRELESS MODEM AT 92" (2335MM) A.F.F. STARBUCKS VENDOR TO DETERMINE OPTIMAL DEVICE LOCATION DEMARC, IF REQUIRED POWER AND DATA RECEPTACLES AT 104" (2642MM) A.F.F. TO CENTER OF GROUPING. SEE NOTE 'B' ABOVE FOR DESCRIPTION SECURITY MONITOR MOUNTED ON MONITOR ARM (ATTACHED TO BACKER BOARD). BACK OF HOUSE CEILING HEIGHT PER PLAN 21 6" 6" 15 0 M M . 15 0 M M . ..4" 100MM LOW VOLTAGE CABLE BUNDLES SECURITY PANEL FUTURE USE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 SECURITY 2 POS HIGH SPEED INTERNET DEMARC EXTENSION POS LAN DT TIMER SECURITY CONTROL ALARM PANEL EMS DATA CONCENTRATOR. ALLOW 2" (50MM) IN. CLEAR ABOVE MAINTAIN 24" (610MM) MIN. CLEARANCE FOR WHEN EQUIPMENT RACK IS IN OPEN ACCESS POSITION (2) SLEEVES FOR LOW VOLTAGE CABLE BUNDLES MOUNTED TO (2) UNISTRUTS EQUIPMENT RACK POWER & DATA RECEPTACLES (IN WALL, ABOVE SHELVES) (1) QUAD RECEPTACLE FOR: EMS DATA CONCENTRATOR (1) DUPLEX RECEPTACLE FOR: SECURITY CONTROL ALARM PANEL (1) 2-DATA PORT FOR: EMS DATA CONCENTRATOR B 2 A POWER RECEPTACLES (IN WALL, BEHIND OF EQUIPMENT RACK) (1) INDIVIDUAL BRANCH CIRCUIT RECEPTACLE FOR: UPS (1) DUPLEX RECEPTACLE FOR: PDU STRIP AND FUTURE USE IOT GATEWAY 2' - 8" DUPLEX RECEPTACLE FOR OPTIONAL MICROWAVE AT 43" (1090MM) A.F.F. OPTIONAL MICROWAVE ON COUNTERTOP BACK WALL EDGE OF COUNTERTOP DUPLEX RECEPTACLE RECEPTACLES AT 28" FOR UNDERCOUNTER FRIDGE UNDERCOUNTER REFRIGERATOR CONVENIENCE DUPLEX RECEPTACLE AT 43" (1090MM) A.F.F. PARTNER SINK 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 5 3 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I504A 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ELECTRICAL DETAILS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 3/4" = 1'-0"1MANAGER DESK (NEW) - LEFT - ELECTRICAL3/4" = 1'-0"9EQUIPMENT RACK RIGHT - ELECTRICAL 3/4" = 1'-0"4PARTNER REST WETBAR - ELECTRICAL Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 EXTERIOR ELEVATIONINTERIOR ELEVATION DOOR ACTUATOR MOUNTED TO 4" X 6" BOLLARD 4/18 GA. WIRE FROM EXTERIOR ACTUATOR TO INTERIOR DOOR OPERATOR WIRE IN CONDUIT EMBEDDED IN CONCRETE OUTLINE OF DOOR OPERATOR AT INTERIOR WIRE FROM KEY SWITCH TO INTERIOR DOOR OPERATOR DOOR OPERATOR KEY SWITCH J-BOX WITH INLINE SWITCH OR ON DEDICATED BREAKER 120V AC 4/18 GA. WIRE FROM ACTUATORS TO OPERATOR DEDICATED RECEPTACLE FOR INSTANT HOT WATER BOILER AT 26" (660MM) A.F.F. (200MM) 8" (240MM) 9 1/2" DUPLEX RECEPTACLE AND DATA PORT AT 47" (1190MM) A.F.F. SHELVING ABOVE 1' - 6 " WW POWER RECEPTACLE AT 18" (457MM) TO TOP OF RECEPTACLE A.F.F. RECEPTACLE FOR WARMING WALL POWER RECEPTACLE AT 18" (457MM) TO TOP OF RECEPTACLE A.F.F. EQ EQ 5' - 0" UNDERCOUNTER REFRIGERATOR QUAD RECEPTACLE FOR LICENSED STORES DPM TABLET AND FUTURE USE RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR 2-DATA PORT FOR LICENSED STORES DPM TABLET AND SPARE POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. 2 6" COUNTERTOP GROMMET FOR DPM TABLET (ONLY FOR LICENSED STORES PROJECTS) 1' - 5 " 5" CEILING ELEVATION - ELECTRICAL DIAGRAM 22 22 RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR RECEPTACLE FOR BLENDER(S)* RECEPTACLE FOR FUTURE USE 2-DATA PORT FOR LABEL PRINTER 2-DATA PORT FOR FUTURE USE *BLENDER QUANTITY BASED ON EQUIPMENT SCHEDULE POWER AND DATA RECEPTACLES AT 28" (710MM) TO TOP OF RECEPTACLE A.F.F. UNDERCOUNTER NITRO REFRIGERATOR RECEPTACLE FOR UNDERCOUNTER NITRO REFRIGERATOR RECEPTACLE FOR NITROGEN GENERATOR RECEPTACLE FOR DPM TABLET 2-DATA PORT FOR DPM TABLET AND FUTURE USE POWER AND DATA RECEPTACLES AT 28" (710MM) TO TOP OF RECEPTACLE A.F.F. POWER RECEPTACLE FOR RINSE SINK AT 28" (710MM) TO TOP OF RECEPTACLE A.F.F. UNDERCOUNTER REFRIGERATOR UNDERCOUNTERNITROGEN GENERATOR PLAN - UPPER ELECTRICAL DIAGRAM 2 RECEPTACLE FOR MILK DISPENSER RECEPTACLE FOR ICE DISPENSER RECEPTACLE FOR LABEL PRINTER AND FUTURE USE 2-DATA PORT FOR LABEL PRINTER POWER AND DATA RECEPTACLES AT 83" (2100MM) TO TOP OF RECEPTACLE A.F.F. RECEPTACLE FOR MILK DISPENSER POWER AND DATA RECEPTACLES AT 83" (2100MM) TO TOP OF RECEPTACLE A.F.F. 2' - 4 " 6' - 1 1 " POWER AND DATA RECEPTACLES AT 28" (710MM) TO TOP OF RECEPTACLE A.F.F. SOFFIT POWER AND DATA RECEPTACLES AT 83" (2030MM) TO TOP OF RECEPTACLE A.F.F. PLAN - ELECTRICAL DIAGRAM JBOX FOR UNDERCABINET LIGHTING 2 1' - 2"2' - 6 1/2"3' - 3 1/2"1' - 2 1/2" 4' - 6 3/4"1' - 0"2' - 9 3/4" 11' - 6" 11' - 6" STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 5 / 2 0 2 4 1 0 : 2 3 : 0 1 A M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I504B 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ELECTRICAL DETAILS 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 1/2" = 1'-0"1ENTRY/EXIT DOOR ACTUATION - ELECTRICAL WIRING DIAGRAM 3/4" = 1'-0"3WATER FILLING STATION - ELECTRICAL3/4" = 1'-0"7WARMING WALL 1000 ELECTRICAL 3/4" = 1'-0"4MOP 07-04 ELECTRICAL 3/4" = 1'-0"9CB CBE 15 ELECTRICAL Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments A A 2301 N Tustin Ave #A8/22/2024 2 2 RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR RECEPTACLE FOR LABEL PRINTER AND FUTURE USE 2-DATA PORT FOR LABEL PRINTER POWER AND DATA RECEPTACLES AT 28" (710MM) TO TOP OF RECEPTACLE A.F.F. RECEPTACLE FOR COMBI OVEN 2-DATA PORT COMBI OVEN POWER AND DATA RECEPTACLES AT 18" (457MM) TO TOP OF RECEPTACLE A.F.F. POWER AND DATA RECEPTACLES AT 28" (710MM) TO TOP OF RECEPTACLE A.F.F. POWER AND DATA RECEPTACLES AT 18" (457MM) TO TOP OF RECEPTACLE A.F.F. ELEVATION - ELECTRICAL DIAGRAM ELEVATION - ELECTRICAL DIAGRAM 1' - 4"3' - 11"1' - 1" 6' - 4" 4"4" 2' - 4 " 1' - 6 " UNDERCOUNTER REFRIGERATORS 2' - 2"1' - 7" 11' - 7" 3' - 6 3/4"3' - 7 1/4"2' - 0 3/4" 1" ( T Y P . ) DEDICATED RECEPTACLE FOR ESPRESSO MACHINE DEDICATED RECEPTACLE FOR INSTANT HOT WATER BOILER RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR AND FUTURE USE POWER RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. IoT MODULE FOR ESPRESSO MACHINE, FOIO (TYP. 1 OF 2) (2) RECEPTACLES FOR LABEL PRINTERS AND/OR CONNECT DEVICES 2-DATA PORT FOR LABEL PRINTERS AND/OR CONNECT DEVICES 2-DATA PORT FOR FUTURE USE POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. 21” X 3” (533MM X 76MM) STUB-UP PENETRATION AREA. SUPPLY POWER AND DATA CONDUIT FOR ESPRESSO MACHINES, INSTANT HOT WATER BOILERS AND ADJACENT NITRO WORKSTATION AS APPLICABLE. SEE BUILDING FLOOR PENETRATION FOR FINAL LOCATION. DEDICATED RECEPTACLE FOR ESPRESSO MACHINE DEDICATED RECEPTACLE FOR INSTANT HOT WATER BOILER RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR AND FUTURE USE POWER RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. UNDERCOUNTER WATER BOILER FOR INSTANT HOT WATER FONT (TYP. 1 OF 2) 2 2 IoTIoT 7' - 6" QUAD RECEPTACLE FOR LABEL PRINTER, FUTURE USE AND/OR CONNECT DEVICES RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR 2-DATA PORT FOR LABEL PRINTER 2-DATA PORT FOR FUTURE USE POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. (2) DEDICATED RECEPTACLE FOR WARMING RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR 2-DATA PORT FOR FUTURE USE POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. UNDERCOUNTER REFRIGERATOR UNDERCOUNTER REFRIGERATOR 4" 4"4" 2 2 2' - 1"4' - 2" 2 3' - 1 1/2"1' - 3" 7' - 6" 1/ 2 " QUAD RECEPTACLE FOR GRINDER AND FUTURE USE DATA PORT FOR FUTURE USE POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. DEDICATED RECEPTACLE FOR BREWER DATA PORT FOR FUTURE USE POWER AND DATA RECEPTACLE AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. 2' - 0" 2" PARTNER SIDE POWER AND DATA RECEPTACLES DEDICATED RECEPTACLE FOR UPS (POS AND PED) 2-DATA PORT FOR POS PED AND/OR CONNECT DEVICES (RELOCATE AS NECESSARY) POWER AND DATA STUB-UPS. SEE BUILDING FLOOR PENETRATION PLAN FOR FINAL LOCATION. POS BANK (TYP.) SAFE (MAY NOT BE INSTALLED AT ALL POS WORKSTATION TYPES) POS MONITOR (TYP.) NOTE: GENERIC DETAIL IS FOR INFORMATION AND COORDINATION ONLY; ENGINEER TO MODIFY AS APPROPRIATE RECEIPT PRINTER (TYP.) CASH DRAWER (TYP.) DEDICATED RECEPTACLE FOR UPS (POS AND PED) 2-DATA PORT FOR PED AND/OR CONNECT DEVICES QUAD RECEPTACLE FOR SAFE AND FUTURE USE 2-DATA PORT FOR FUTURE USE POWER AND DATA RECEPTACLES (RELOCATE AS NECESSARY) 18" X 3" (457MM X 76MM) STUB-UP PENETRATION AREA. SUPPLY POWER, DATA AND PHONE CONDUITS FOR POS AND POWER CONDUIT FOR PASTRY CASE. SEE BUILDING FLOOR PENETRATION PLAN FOR FINAL LOCATION.EDGE OF COUNTERTOP BOX BASE (BELOW)UNDERCOUNTER SAFE EDGE OF CABINET SHELVING (BELOW) 6' - 10" DEDICATED RECEPTACLE FOR POS 2-DATA PORT FOR POS AND FUTURE USE POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. 2 2 2 DEDICATED RECEPTACLE FOR UPS (POS AND PED) 2-DATA PORT FOR POS, PED AND/OR CONNECT DEVICES POWER RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. QUAD RECEPTICLE FOR FUTURE USE 2-DATA PORT FOR FUTURE USE POWER RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. 4' - 4"1' - 3" 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 5 5 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I504C 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ELECTRICAL DETAILS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 3/4" = 1'-0"1CB WRM 14 ELECTRICAL3/4" = 1'-0"9ESP 10-01 ELECTRICAL 3/4" = 1'-0"11WRM 08-02 ELECTRICAL 3/4" = 1'-0"12BRW 09-01 ELECTRICAL NOT USED NOT USED 3/4" = 1'-0"4GENERIC DOUBLE POS ELECTRICAL & PLLUMBING DIAGRAM 3/4" = 1'-0"3POS 01-01 ELECTRICAL Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 1' - 3"1' - 9" 6' - 6" 42 2 DEDICATED QUAD RECEPTACLE FOR DT DIGITAL PRODUCTION MONITOR, UPS UNIT (FOR TENDERING REGISTER EXPEDITOR, POS AND PED) AND FUTURE USE DEDICATED QUAD RECEPTACLE FOR FUTURE USE 2-DATA J-BOX 4-DATA J-BOX POWER AND DATA RECEPTACLES DEDICATED QUAD RECEPTACLE FOR DRIVE THRU TIMER MONITOR AND CONTROL UNIT. (2) DEDICATED DUPLEX RECEPTACLE FOR WIRELESS BASE AND SIGNAL PROCESSOR WITH CIRCUIT ISOLATED GROUND 2-DATA J-BOX SINGLE DATA J-BOX POWER AND DATA RECEPTACLES QUAD RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR AND FUTURE USE POWER RECEPTACLE UNDERCOUNTER REFRIGERATOR DUPLEX CONVENIENCE POWER RECEPTACLE EDGE OF COUNTERTOP NOTE: EQUIPMENT SHOWN AS DASHED LINES IS TO BE FURNISHED AND INSTALLED BY OWNER UNLESS NOTED OTHERWISE DRIVE THRU DIGITAL PRODUCTION MONITOR ELEVATION VIEW DRIVE THRU TENDERING REGISTER TRIPLE MONITOR MOUNT (GC INSTALLED) SEE PLAN VIEW FOR MOUNTING LOCATION POWER RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. DEDICATED QUAD RECEPTACLE FOR DT DIGITAL PRODUCTION MONITOR, UPS UNIT (FOR TENDERING REGISTER, EXPEDITOR POS AND PED) AND FUTURE USE DEDICATED QUAD RECEPTACLE FOR FUTURE USE 2-DATA PORT FOR TENDERING REGISTER AND EXPEDITOR POS 4-DATA PORT FOR DT VIDEO, PED AND/OR CONNECT DEVICES POS BANK (TYP) CASH DRAWERS ELEVATION VIEW DRIVE THRU VIDEO CONDUIT FROM DT ORDER POINT TO DT VIDEO DATA BOX AT 28" (711MM) A.F.F. DRIVE THRU EXPEDITOR POS RECEIPT PRINTER DT AUDIO CONDUIT FROM DRIVE THRU ORDER POINT AND DETECTOR LOOP CONDUIT FROM DT WINDOW TO DT TIMER CONTROL DATA JUNCTION BOXES AT 8'-2" (2490MM) POWER RECEPTACLE AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. QUAD RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR AND FUTURE USE SINGLE DOOR REFRIGERATOR DUPLEX CONVENIENCE OUTLET AT 45" (1143MM) TO TOP OF RECEPTACLE A.F.F. * 5 " * 1' - 11 1/2" DIMENSIONS INDICATE CENTER MOUNTING POINT FOR MONITOR BASE * DRIVE THRU WIRELESS HEADSET BASE STATION DRIVE THRU TIMER MONITOR DRIVE THRU TIMER CONTROL UNIT POWER AND DATA RECEPTACLES AT 8'-2" (2490MM) TO TOP OF RECEPTACLES A.F.F. DEDICATED QUAD RECEPTACLE FOR DRIVE THRU TIMER MONITOR AND CONTROL UNIT (2) DEDICATED DUPLEX RECEPTACLE FOR WIRELESS BASE AND SIGNAL PROCESSOR WITH CIRCUIT ISOLATED GROUND 2-DATA PORT FOR DT TIMER AND CONTROL UNIT SINGLE DATA PORT FOR DT AUDIO (MIC & SPEAKER) DRIVE THRU TIMER SIGNAL PROCESSOR (TSP) 36" W X 51" H (915MM W X 1295MM H) MIN. FIRE RATED PLYWOOD BACKER BOARD. FASTEN TO STRUCTURE. WALL FINISH TO CONCEAL. FUTURE HHOP CABLING TO HEADSET BASE STATION FROM J-BOX AT CLG/WALL FOR EXTERNAL EXTENDED COVERAGE ANTENNA (FOIO) 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 5 5 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I504D 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES ELECTRICAL DETAILS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 3/4" = 1'-0"1DTP 03-02 ELECTRICAL NOT USEDNOT USEDNOT USEDNOT USEDNOT USED NOT USEDNOT USEDNOT USED NOT USEDNOT USEDNOT USED NOT USEDNOT USEDNOT USED Revision Schedule Rev Date By Description STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 OPTIONAL MICROWAVE ON COUNTERTOP BACK WALL EDGE OF COUNTERTOP UNDERCOUNTER REFRIGERATOR PARTNER SINK HOT AND COLD WATER FOR SINK FAUCET AT 20 1/2" (520MM) A.F.F. SHUT- OFF VALVES AT WALL AND 4" (100MM) EITHER SIDE OF WASTE LINE. DIRECT DRAIN LINE FROM RINSE SINK HOT AND COLD WATER FOR SINK FAUCET AT 20 1/2" (520MM) A.F.F. SHUT- OFF VALVES AT WALL AND 4" (100MM) EITHER SIDE OF WASTE LINE. FILTERED COLD WATER SUPPLY FOR BREWER WITH SHUT-OFF IN CABINET AT 24" (610MM) A.F.F. 7' - 6" * PROVIDE BACKFLOW PREVENTION DEVICE THEN WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE CONNECTION * FLOOR SINK 10" F L O O R S I N K 2' - 5 1 / 2 " SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION AND TYPE INDIRECT DRAIN LINE FROM RINSE SINK TO FLOOR SINK INDIRECT DRAIN LINE FROM BREWER TO FLOOR SINK DIRECT DRAIN LINE FROM SINK. ROUGH-IN SINK WASTE STUB AT 15 1/2" (394MM) A.F.F. AND CENTERLINE OF SINK TEMPERED HOT AND COLD WATER FOR SINK FAUCET AT 20 1/2" (520MM) A.F.F. SHUT-OFF VALVES AT WALL AND 4" (102MM) EITHER SIDE OF WASTE LINE. 7 1/2" 1' - 3" FILTERED COLD WATER SUPPLY FOR WATER TOWER FAUCET* FILTERED COLD WATER SUPPLY FOR INSTANT HOT/COLD WATER FONT NON-FILTERED HOT AND COLD WATER SUPPLY FOR SINK FAUCET ABOVE COUNTERTOP AT FLOOR LEVEL INDIRECT LINE FROM PREP SINK ABOVE TO FLOOR SINK SHELVING ABOVE FILTERED COLD WATER SUPPLY FOR UNDERCOUNTER INSTANT HOT WATER BOILER (LOCATION MAY VARY) ** PROVIDE WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE CONNECTION* IN-WALL INDIRECT DRAIN LINE FROM ICE DISPENSER TO FLOOR DRAIN OUTLET BOX FOR INDIRECT DRAIN LINE FLOOR DRAIN SOFFIT OUTLET BOX FOR INDIRECT DRAIN LINE FLOOR DRAIN OUTLET BOX FOR INDIRECT DRAIN LINE 1' - 0 " 4' - 7 1 / 2 " CEILING OUTLET BOX FOR INDIRECT DRAIN LINE ICE TRANSPORT TUBE LANE 1, TO ICE DISPENSER. MAX LENGTH 75', MIN. SLOPE 1/4":1'. CONTINUOUS CONDUIT FASTENED W/ STRAPING @ 48" O.C. MIN. CEILING IN-WALL INDIRECT DRAIN LINE FROM ICE DISPENSER TO FLOOR DRAIN SOFFIT INDIRECT LINE FROM DRAINBOARD TO FLOOR SINK HOT AND NON-FILTERED COLD WATER FOR SINK FAUCET AT 20 1/2" (20MM) A.F.F. SHUT-OFF VALVES AT WALL AND 4" (100MM) EITHER SIDE OF WASTE LINE NON-FILTERED COLD WATER SUPPLY FOR BLENDER PITCHER RINSER INDIRECT DRAIN LINE FROM SINK TO FLOOR SINK FILTERED COLD WATER SUPPLY FOR WATER TOWER FAUCET DRAIN LINES FROM DRAIN TRAY AND UNDERCOUNTER REFRIGERATOR; SEPARATE, INDIRECT TERMINATION AT FLOOR SINK SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION AND TYPE ELEVATION - PLUMBING DIAGRAMSECTION A - PLUMBING DIAGRAM ACCESS DOOR DOOR FACE W/ TAPERED EDGE PULL MOUNTING TEMPLATE, BLACK IN-WALL BLOCKING REQUIRED, PROVIDED BY G.C. FRAMING, BLACK ACCESS DOOR ICE TRANSPORT TUBE LANE 1, TO ICE DISPENSER. MAX LENGTH 75', MIN. SLOPE 1/4":1' CONTINUOUS CONDUIT FASTENED W/ STRAPING @ 48" O.C. MIN. A VA R I E S 11' - 6" 6" 6" EQ EQ STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 5 / 2 0 2 4 1 0 : 2 3 : 0 3 A M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I505 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES PLUMBING DETAILS 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 3/4" = 1'-0"12PARTNER REST WETBAR - PLUMBING 3/4" = 1'-0"4BRW 09-01 PLUMBING 3/4" = 1'-0"17ADD 02-01 PLUMBING 3/4" = 1'-0"18WATER FILLING STATION - PLUMBING NOT USED 3/4" = 1'-0"1CB CBE 15 PLUMBING Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments A 2301 N Tustin Ave #A8/22/2024 11' - 7" ABOVE COUNTER ICE BIN (TYP. 1 OF 2)NON-FILTERED COLD WATER SUPPLY FOR METERED SPOON RINSER (TYP. 1 OF 2) NON-FILTERED COLD WATER SUPPLY FOR PITCHER RINSER (TYP. 1 OF 2) RINSER SINK (TYP. 1 OF 2) 2' - 1 0 1 / 2 " UNDER COUNTER ICE BIN ABOVE WITH INDIRECT AND INSULATED DRAIN LINE TO FLOOR SINK BELOW 7"X3" (180MMX75MM) STUB-UP PENETRATION AREA. SEE BUILDING FLOOR PENETRATION PLAN FOR FINAL LOCATION. INSTALL SHUT-OFF VALVES BETWEEN STUB-UPS AND EQUIPMENT INDIRECT DRAIN LINE FROM ESPRESSO MACHINE TO FLOOR SINK INDIRECT DRAIN LINE FROM RINSER SINK TO FLOOR SINK FLOOR SINK (TYP. 1 OF 2) SEE PLUMBING PLAN FOR FINAL LOCATIONS AND TYPE ICE BIN ABOVE WITH INDIRECT AND INSULATED DRAIN LINE TO FLOOR SINK BELOW COUNTERTOP SUPPORT LEG (TYP. 1 OF 3) INDIRECT DRAIN LINE FROM RINSER SINK TO FLOOR SINK UNDERCOUNTER CABINET UNDERCOUNTER REFRIGERATOR (TYP. 1 OF 2) UNDERCOUNTER BOILER FOR INSTANT HOT WATER FONT (TYP 1 OF 2) UNDERCOUNTER REFRIGERATOR (TYP. 1 OF 2) 11 1/2"6' - 1" INDIRECT DRAIN LINE FROM ESPRESSO MACHINE TO FLOOR SINK FILTERED COLD WATER SUPPLY FOR INSTANT HOT/COLD WATER FONT (TYP. 1 OF 2) * FILTERED COLD WATER SUPPLY FOR WATER TOWER DISPENSER (TYP. 1 OF 2) * FILTERED COLD WATER SUPPLY FOR ESPRESSO MACHINES ** UNDERCOUNTER CABINET FILTERED COLD WATER SUPPLY FOR INSTANT HOT/COLD WATER BOILER (TYP. 1 OF 2) *PROVIDE WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE CONNECTION* **PROVIDE BACKFLOW PREVENTION DEVICE BEFORE PUMP AND WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE ELEVATION - PLUMBING DIAGRAM PLAN - PLUMBING DIAGRAM 6' - 6" FLOOR DRAIN FILTERED WATER SUPPLY FOR COMBI OVEN WATER INJECTION WITH SHUT-OFF IN CABINET AT 18" (457MM) A.F.F. COLD WATER SUPPLY FOR COMBI OVEN CLEANING WITH SHUT- OFF IN CABINET AT 18" (457MM) A.F.F. COLD WATER SUPPLY FOR COMBI OVEN CLEANING WITH SHUT- OFF IN CABINET AT 18" (457MM) A.F.F. FILTERED WATER SUPPLY FOR COMBI OVEN WATER INJECTION WITH SHUT- OFF IN CABINET AT 18" (457MM) A.F.F. INDIRECT DRAIN LINE FROM COMBI OVEN TO FLOOR SINK SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION AND TYPE INDIRECT DRAIN LINE FROM ICE MACHINE TO FLOOR DRAIN SEE PLUMBING PLAN FOR FINAL FLOOR DRAIN LOCATION AND TYPE .6" (152MM) MIN. CLEAR TO BACK WALL INDIRECT DRAIN LINE FROM ICE BIN TO FLOOR DRAIN INDIRECT DRAIN LINE FROM ICE DIVERTER TO FLOOR DRAIN ICE MACHINE ICE TRANSPORT TUBE BETWEEN ICE MACHINE AND DIVERTER VALVE. MAX. LENGTH 10' (3M) ICE HEAD ADAPTER ICE TRANSPORT TUBE LANE 2, TO ICE BIN. MAX LENGTH 75', MIN. SLOPE 1/4":1' ICE TRANSPORT TUBE LANE 1, TO ICE DISPENSER. MAX LENGTH 75', MIN. SLOPE 1/4":1' 3" PVC SLEEVE TO SUPPORT ICE TRANSPORT TUBEFASTENED TO WALL OR CEILING W/ STRAPING @ 48" O.C. MIN. ICE DIVERTER VALVE ELEVATION - PLUMBING DIAGRAM PLAN - PLUMBING DIAGRAM CONT. FRP TO CEILING ON BACK WALL OVER IN WALL BLOCKING ICE BIN ICE MACHINE ICE HEAD ADAPTER NOTE: INDIRECT DRAIN MIN. RADIUS = 8" ICE TRANSPORT TUB MIN. RADIUS = 6" NOTE: INDIRECT DRAIN MIN. RADIUS = 8" ICE TRANSPORT TUB MIN. RADIUS = 6" ECO-GRIP COVER BASE ICE MANAGER CONTROL PANEL ICE DIVERTER VALVE CONT. FRP ON BACK WALL OVER IN WALL BLOCKING BACK WALL MIN. r 6" BIN TOP SENSOR DISTRIBUTION UNIT ICE BIN INDIRECT DRAIN LINE FROM ICE MACHINE TO FLOOR DRAIN 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 5 7 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I505A 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES PLUMBING DETAILS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 Revision Schedule Rev Date By Description 3/4" = 1'-0"9ESP 10-01 PLUMBING 3/4" = 1'-0"11CB WRM-14 PLUMBING NOT USED NOT USED 3/4" = 1'-0"1PLUMBING - NUGGET ICE - PEDESTAL STACK1 STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 CONFIGURATION III WATER FILTRATION SYSTEM. SEE CONFIGURATION III, R.O. AND SOFTENER DETAIL FOR MORE INFORMATION. R.O. PERMEATE TANK FRP ENCLOSED CL E A R 6" ( 1 5 0 M M ) BA C K E R 4' - 2 " ( 1 2 7 0 M M ) 2' - 6 " ( 7 6 5 M M ) 7' - 2 " ( 2 1 8 5 M M ) NOTE: 1. KEEP CLEAR AT BACKWALL FOR CHEMICAL DISPENSING SYSTEM COMPONENTS, TO BE INSTALLED BY SYSTEM VENDOR. REFER TO POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION 2' - 0 " ( 6 1 0 M M ) OPEN CEILING ABOVE WATER HEATER PER LOCAL CODE STRAP UNITS PER LOCAL CODE REQUIREMENTS PROVIDE MOISTURE- RESISTANT BLOCKING TO STRUCTURE BEHIND WALL FINISH AT THESE AREAS. REFER TO ITEM SPECIFICATIONS FOR PLUMBING SCOPE; COORDINATE INSTALL WITH FILTER VENDOR. FRP ENCLOSED HOT WATER TANK. SEE SPECIFICATIONS AND WATER HEATER TANK DETAIL FOR MORE INFORMATION. MOP HOLDER 3' - 0 " ( 9 1 5 M M ) 5' - 0 " ( 1 5 2 5 M M ) HOSE CLIP HOT AND COLD WATER SUPPLY FOR FAUCET MOP SINK SEE NOTE 1 BELOW SEE NOTE 1 BELOW 2' - 0" (610MM) 6' - 0" (1830MM) MIN. BLENDED STORAGE TANK ON WALL MOUNTED SHELF WATER BOOSTER PUMP SEE BOOSTER PUMP DETAIL FOR MORE INFORMATION. FRP ENCLOSED 9' - 6 " ( 2 8 9 5 M M ) T O B O T T O M O F B L E N D E D S T O R A G E T A N K SH E L F 3/4" (20MM) CHROME ESCUTCHEONS (TYP.) 3/4" (20MM) BRASS THREADED BALL SHUT-OFF VALVE (TYP.) MAX 72" (1830MM) A.F.F. UNION (TYP.) 3/4" (20MM) FILTERED COLD WATER TO ICE MACHINE POINT OF USE FILTER LOCATED AT ICE MACHINE MOP SINK NOTES: 1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. GC TO COORDINATE INSTALLATION OF ALL OTHER COMPONENTS SHOWN WITH FILTER VENDOR. 2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND FROM SOFTNER TO ADVANSYS DISHWASHER WHERE ALLOWED BY CODE. 3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES. 4. PROVIDE WATER SOFTENER INDIRECT DRAIN TO SINK, INSTALLED PER CODE. (CONFIRM REQUIREMENTS WITH SOFTENER EQUIPMENT CUTSHEETS IN ITEM SPECIFICATIONS). 5. IN MUNICIPALITIES WITH BRINE RESTRICTIONS, REFER TO THE WATER SYSTEM CONFIGURATIONS APPENDIX UNDER ITEM SPECIFICATIONS FOR WATER SOFTENER EXCHANGE TANK SCHEMATIC. 6. COMPONENTS ARE TO BE POSITIONED TO MAXIMIZE ACCESS FOR REGULAR SERVICING. PRE-FILTER, BYPASS VALVES, AND SOFTENER TANKS MUST BE INSTALLED 72" (1828MM) AFF OR LOWER. R.O. PERMEATE TANK (180MM) 7"(235MM) 9 1/4" GFCI 120V QUAD RECEPTACLE FOR FILTER SYSTEM 77" (1955MM) A.F.F. (SEE NOTE 3)FILTERED COLD WATER TO FIXTURES (ESPRESSO MACHINES, BREWERS, HOT TAP, WATER TOWER FAUCET) 75 " ( 7 9 0 5 M M ) OUT R.O. CONTROL SYSTEM (SEE NOTE 5) 3/4" (20MM) SHUT-OFF VALVE 3/4" (15MM) FIP 3/4" (20MM) SHUT-OFF VALVE 3/4" (20MM) BYPASS 3/4" (20MM) SHUT-OFF VALVE CITY WATER IN TO NON FILTERED FIXTURES (TOILETS, HAND SINKS, DIPPER WELLS, BLENDER PITCHER RINSERS, IN-COUNTER RINSERS, BAR SINKS, HOSE BIBBS) 3/4" (20MM) FIP (FEMALE INTERNATIONAL PIPE THREAD FITTING) (TYP. 1 OF 2 TO SOFTENER) GFCI 120V RECEPTACLE FOR FILTER SYSTEM AT 54" (1372MM) A.F.F. (SEE NOTE 3) IN DI EXCHANGE (EXISTING) WATER SOFTENER HEAD AND TANKS (BEHIND) DRAIN LINE FROM WATER HEATER TANK PAN ABOVE 255MM) 11" 3" (75MM) WATER HEATER TANK SEE WATER HEATER TANK DETAIL FOR MORE INORMATION FROM WATER HEATER TANK TEMPERING VALVE OUT IN IN TO HOT WATER TANK AND ADVANSYS DISHWASHER PLUMBING. SEE WATER HEATER TANK DETAIL FOR MORE INORMATION BYPASS VALVE BLENDED STORAGE TANK ON WALL MOUNTED SHELF 5' - 0 " ( 1 5 2 5 M M ) TO R.O. SYSTEM BOOSTER PUMP BYPASS VALVE 3/4" (20MM) CITY WATER IN BOOSTER PUMP SHUT-OFF VALVE TO BOOSTER PUMP 3/4" (20MM) BOOSTED WATER IN 5' - 9 " ( 1 7 5 0 M M ) WATER FILTRATION BOOSTER PUMP. SEE BOOSTER PUMP DETAIL FOR MORE INFORMATION HOT WATER TANK (SEE SPECIFICATIONS & HOT WATER TANK DETAIL FOR FURTHER INSTALLATION REQUIREMENTS) 1" (25MM) BRASS CHECK VALVE EXPANSION TANK STRAP UNITS PER LOCAL REQUIREMENTS HOT WATER TO DISHWASHER (IF OTHER THAN HOBART ADVANSYS UNIT), BAR SINKS, MOP SINK AND COMPARTMENT SINK. 1" (25MM) HOT WATER OUTLET TEMPERED HOT WATER TO HAND SINKS TEMPERATURE MIXING VALVES UNION (TYP.)CONCEALED COPPER PIPING (TYP.) IF CONFIGURATION II OR III, SOFTENED COLD WATER TO DISHWASHER (IF HOBART ADVANSYS UNIT). SEE NOTE 2 BELOW. OPEN CEILING ABOVE WATER HEATER PER LOCAL CODE PAN AND DRAIN LINE FOR MAINTENANCE BOOSTER PUMP. SEE BOOSTER PUMP DETAIL FOR MORE INFORMATION. FL O W DI R E C T I O N NOTES: 1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. 2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND ADVANSYS DISHWASHER WHERE ALLOWED BY CODE. 3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES. 4.. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED.. SHELF PER ENGINEER'S DRAWINGS FLOW DIRECTION 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 5 8 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I505B 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES PLUMBING DETAILS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 Revision Schedule Rev Date By Description 1/2" = 1'-0"1CONFIGURATION III1" = 1'-0"9CONFIGURATION III, R.O. AND SOFTENER WATER FILTRATION 3/4" = 1'-0"3WATER HEATER TANK - PLUMBING STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 Plan View KEEP CLEAR FOR WALL MOUNTED CHEMICAL DISPENSING SYSTEM, TO BE INSTALLED BY SYSTEM VENDOR. PROVIDE BACKING BEHIND WALL FINISH FOR EQUIPMENT MOUNTING. REFER TO POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION. Elevation View SOFTENED HOT AND NON-FILTERED COLD WATER FOR SINK FAUCET INDIRECT DRAIN LINE FROM DISHWASHER TO NEAREST FLOOR SINK. BACK WALL WATER FOR DISHWASHER WITH SHUT-OFF UNDER SINK AT 18" (460MM) AFF. LINE LENGTH MUST ALLOW EASE OF MOVEMENT. VERIFY WATER REQUIREMENTS FOR TYPE OF DISHWASHER (HOT/COLD/SOFTENED). SEE WATER SUPPLY DRAWINGS FOR WATER LINE. IF ADVANSYS DISHWASHER, INCLUDE PRESSURE REDUCING VALVE. PRESSURE GAUGE (SET TO 20 PSIG +/- 5 PSI), LINE STRAINER AND SHOCK ARRESTOR. DRAIN LINE FROM SINK TO FLOOR SINK BELOW SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION. FLOOR DRAIN OPTIONAL. WIRE RACK COMPARTMENT SINK DISHWASHER NOTE: FOR COORDINATION ONLY. SEE FURNITURE, FIXTURES, AND EQUIPMENT PLAN FOR EQUIPMENT LOCATIONS. PROVIDE BACKING BEHIND WALL FINISH AS REQUIRED FOR WALL MOUNTED EQUIPMENT. REFER TO ITEM SPECIFICATIONS FOR MORE INFORMATION. PRE-WASH STATION (1 3 7 0 M M ) 4' - 6 " DRAIN LINE FROM DISHWARE DRYING RACKS TO SINK BOWL DISHWARE DRYING RACKS WITH DRAIN LINE TO SINK BOWL ALIGN (1 1 9 5 M M ) 3' - 1 1 " (9 6 5 M M ) 3' - 2 " 12' - 3" 3/4" PLYWOOD BACKER BOARD BEHIND WALL FINISH. FASTEN TO STRUCTURE BEYOND. B MOP SINK AND WATER FILTRATION EQUIPMENT. SEE PLAN FOR ACTUAL CONFIGURATION. WATER HEATER TANK PER PLAN HOT WATER TANK CHASE TO STRUCTURE OR HARD LID ABOVE. PAINT INTERIOR GWB FINISH TO MATCH BOH FRP. ROOF STRUCTURE PER PLAN MIN CLEAR 2' - 8" (815MM) 7' - 2 " ( 2 1 8 5 M M ) M I N . T O B O T O M O F S H E L F BOTTOM OF WORKROOM CEILING IN FOREGROUND OPEN TO WORKROOM A SECTION A HOT WATER PIPING AND FLUE. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED. BO H C E I L I N G H E I G H T P E R P L A N 2" ( 5 0 M M ) BOOSTER PUMP EXTEND BULKHEAD AND BACK SURROUNDING WALLS TO STRUCTURE ABOVE SECTION B ENSURE WATER TANK CHASE IS FULLY SEALED FOR PEST EXCLUSION 3' - 3" (915MM) 8' - 9 " ( 2 6 7 0 M M ) A. F . F . NOTES: 1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. 2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND ADVANSYS DISHWASHER WHERE ALLOWED BY CODE. 3. POSITION BOOSTER PUMP SO THAT PRESSURE GAUGE IS READABLE AND ACCESSIBLE FOR TROUBLESHOOTING AND MAINTENANCE. 4. BOOSTER PUMP STATIC AND DYNAMIC OUTLET PRESSURE SHALL BE BETWEEN 65 TO 70 PSI. VERIFY PER PUMPS INTEGRAL PRESSURE GAUGE. 5. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES. 6. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED. 7. PROVIDE VIBRATION DAMPENING AT BOOSTER PUMP MOUNT TO PLATFORM. WATER HEATER TANK. SEE WATER HEATER TANK DETAIL FOR MORE INFORMATION. GFCI 120V RECEPTACLE FOR BOOSTER PUMP MIN. CLEAR 2" (50MM)CITY WATER IN OUT TO WATER FILTRATION SYSTEM BOOSTER PUMP. SECURE TO SHELF BELOW WITH BOLTS THROUGH BASE PLATE SHELF PER ENGINEER'S DRAWINGS 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 4/ 1 5 / 2 0 2 4 1 2 : 1 7 : 5 9 P M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I505C 76085-018 04-15-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES PLUMBING DETAILS 1S T P E R M I T S U B M I T T A L - 0 4 - 1 5 - 2 0 2 4 Revision Schedule Rev Date By Description 3/4" = 1'-0"1SANITIZING (GENERIC) - PLUMBING1/2" = 1'-0"13WATER HEATER TANK CHASE 1" = 1'-0"15BOOSTER PUMP - PLUMBING NOT USEDNOT USEDNOT USED STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 2301 N Tustin Ave #A8/22/2024 DOOR LEGEND SINGLE IMPACT DOUBLE ACTING SINGLE FLUSH INTERIORINTERIOR WINDOW LEGEND DRIVE-THRU WINDOW OPENING NOT TO EXCEED 432 SQ.IN. STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 9 / 2 0 2 4 1 0 : 1 2 : 1 1 A M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I601 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES CASEWORK AND FF&E SCHEDULES 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 SPECIALTY EQUIPMENT SCHEDULE - "E" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS COOLING 10267 2 FRIDGE UNDERCOUNTER 1 DOOR - 27IN 685MM SB MANUF: DELFIELD, MODEL: 400P-STAR2 12618 1 FRIDGE UNDERCOUNTER 1 DOOR WITH SHELF - 27IN 685MM SB MANUF: TRAULSEN, MODEL: UHT27R0-0300-ZSB02 13620 1 FREEZER REACH IN 1 DOOR LH - 27IN 685MM SB MANUF: TRUE FOOD SERVICE EQUIPMENT, INC., MODEL:T-23F-HC-LH STAR 20010 1 FRIDGE NITRO 2 TAP JT NITCOM LH VD KIT INCLUDES UNDERCOUNTER FRIDGE, FONT, TRAY, AND TUBING EQUIPMENT 17564 1 BLENDER PITCHER RINSER WITH SENSOR SB MANUF: VITAMIX, MODEL: VM0183 22885 1 BREWER CLOVER VERTICA DOUBLE SB MANUF: DONLIM, MODEL: CM9700 23380 1 BREWER CLOVER VERTICA INSTALL KIT SB MANUF: PENTAIR, MODEL: EV9910-00 23381 1 BREWER CLOVER VERTICA CORD SB MANUF: DONLIM, MODEL: CM9700 23393 3 EQUIPMENT - CBE MILK DISPENSE BRACKET SLIDE SB MANUF: DONLIM, MODEL: RE1003-UL 23419 3 MILK DISPENSER SB MANUF: DONLIM, MODEL: RE1003-UL 23442 1 OVEN COMBI SB MANUF: CONVOTHERM, MODEL: CONVOTHERM MINI EASYTOUCH 23454 1 BOH PARTNER AREA MICROWAVE OVEN - BLACK GC MANUF: PANASONIC, MODEL: NN-SU656B (OR EQUIVALENT) FOOD CASE 16238 1 FOOD CASE - ZEPHYR - 66IN 1675MM SB MANUF: STRUCTURAL CONCEPTS, MODEL: SBZ6652DR 23444 1 FOOD CASE - WARMING WALL - 1000 SQUARE SB MANUF: FLEXESERVE, MODEL: 1000 SQUARE ICE 19278 2 ICE - BIN DROP IN 45LB 20KG HORIZONTAL SB MANUF: ELKAY, MODEL: CUSTOM ICE BIN 23182 1 ICE - MACHINE HMD1810RBT REMOTE COOLED SB MANUF: FOLLET, MODEL: HMD1810RBT 23421 1 ICE - NUGGET ICE DISPENSER - SINGLE ICE MACHINE SB MANUF: FOLLET, MODEL: ID50 23423 1 ICE - NUGGET ICE DIVERTER SB MANUF: FOLLET, MODEL: IMDV-2CM SERIES 23526 1 ICE - BIN ADAPTOR FOLLETT B110H22H30DV PEDESTAL FOR B110 SB MANUF: FOLLET, MODEL: B110H22H30DV OTHER 10099 2 RESTROOM TOILET PAPER HOLDER SB MANUF: ASI, MODEL: 0030 10172 2 RESTROOM SEAT COVER DISPENSER SB MANUF: GAMCO, MODEL: TSC-1 10859 2 RESTROOM GRAB BAR - 48IN 1220MM SB MANUF: ASI, MODEL: 3400 10862 2 RESTROOM GRAB BAR - 36IN 915MM SB MANUF: ASI, MODEL: 3400 10947 1 SOAP DISPENSER WALL MOUNTED SB MANUF: GAMCI, MODEL: G-58AP 10977 1 PAPER TOWEL DISPENSER FULL SIZE SB MANUF: GEORGIA PACIFIC, MODEL: 56650A 10992 2 PAPER TOWEL DISPENSER HALF SIZE - TRANSLUCENT GRAY GC MANUF: GEORGIA PACIFIC, MODEL: 56640 11115 4 SOAP DISPENSER SINK MOUNTED SB MANUF: GAMCO, MODEL: G-64LB 23420 2 REFRESHER DISPENSE SMALL SB MANUF: WOODMAX, MODEL: WK054 STORAGE 10222 1 WIRE SHELF GRID AT SINK SB MANUF: SPG, MODEL: STBKWT2Y 10416 2 WORKROOM SHELVING - 36IN 915MM SB MANUF: SPG, MODEL: WST966 10462 2 WORKROOM SHELVING POSTS SB MANUF: SPG, MODEL: STBKP86Z4 10698 1 MOP RACK WITH 3 HOLDERS SB MANUF: GAMCO, MODEL: MS-1A 13578 1 DISHWARE DRYING RACK - 21IN 535MM SB MANUF: SPG, MODEL: WMRS-21-KD 21934 1 PASTRY TRAY RACK UNDERCOUNTER - 30IN 760MM VD MANUF: WIN-HOLT, MODEL AL-1308H-DW-TG 22212 1 WORKROOM SHELVING CART KIT SB MANUF: SPG, MODEL: WST1878C 23445 3 PASTRY COOLING RACK WALL MOUNTED SB MANUF: CHANNEL, MODEL: BUN PAN RACKS PLUMBING FIXTURE SCHEDULE - "P" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS DRAIN 10594 2 DRAIN - SQUARE - 5IN 125MM GC LOCALLY SOURCED X10726 8 DRAIN - GRATE HALF SQUARE - 12IN 305MM GC MANUF: ZURN, MODEL: Z1855 FAUCET 10152 2 FAUCET - DOUBLE LABORATORY WITH BENT RISER SPOUT SB MANUF: ZURN, MODEL: Z826S1-XL 10153 3 FAUCET - WATER TOWER - 12IN 305MM SB MANUF: CHG, MODEL: KL26-5012-SP 10215 1 FAUCET - DOUBLE LABORATORY WITH SWING SPOUT SB MANUF: ZURN, MODEL: Z826F1-XL 10447 1 FAUCET - PRE RINSE SPRAYER WALL MOUNTED SB MANUF: ENCORE, MODEL: KL53-1000-BLF 10597 2 FAUCET - SINGLE HANDLE SB MANUF: ZURN, MODEL: Z7440-XL 10804 1 FAUCET - PRE RINSE SWING SPOUT SB MANUF: ENCORE, MODEL: KL55-7012-SE4 10922 1 FAUCET - MOP SINK WALL MOUNTED SB MANUF: ZURN, MODEL: Z843M1 11003 2 FAUCET - METERED SB MANUF: CHICAGO FAUCETS, MODEL: 333-665PSHABCP 13588 1 FAUCET - HAND SINK WALL MOUNTED SB MANUF: ENCORE, MODEL; KL45-4000-SC4 21352 2 FAUCET - RESTROOM WITH MOTION SENSOR SB MANUF: ZURN, MODEL: Z6955-XL-S 22642 2 FAUCET - INSTANTHOT SYSTEM 2 BUTTON WITH BOILER AND BRACKET SB MANUF: MARCO, MODEL: MIX UC3 HOT/ AMBIENT. KIT INCLUDES FONT, UNDERCOUNTER BOILER AND BOILER BRACKET FOR SIDE PANEL MOUNTING. BRACKET CAN BE FLOOR MOUNTED USING SET OF (4) STAINLESS STEEL LEGS, ORDERED SEPARATELY THROUGH VENDOR. FILTER 23355 1 FILTER - FILTRATION BOOSTER PUMP VD MANUF: GRUNDFOS, MANUF: CMBE 1-75 I-X-C-B-D-E OTHER 21669 1 GREASE INTERCEPTOR GB75 GC MANUF: SCHIER, MODEL: GB-75 X21676 1 GREASE SAMPLE PORT - SV10 GC MANUF: SCHIER, MODEL: SV-10 SINK 10116 2 SINK - RESTROOM WALL MOUNTED SB MANUF: KOHLER, MODEL: K-2005 10549 2 SINK - RINSE DROP IN SST - 12X20IN 305X510MM SB MANUF: ELKAY, MODEL: P393 10995 1 SINK - MOP - 24X24IN 610X610MM SB MANUF: ZURN, MODEL: Z1996-24 13700 1 SINK - 3 COMP WORK SST - 105IN 2665MM VD MANUF: ELKAY, MODEL: 3C18X20-L20-R26 14688 1 SINK - HAND WITH SIDE SPLASH WALL MOUNTED SST SB MANUF: ENCORE, MODEL: FS17D-1410-05 17565 1 SINK - RINSE WITH DRAINBOARD - 15X27IN 380X685MM SB MANUF: ELKAY, MODEL: 11232015 22768 2 SINK - COUNTERTOP RINSER WITH WATER TOWER - 26X9IN 660X235MM SB MANUF: ELKAY, MODEL: OSB216773X TOILET 11871 2 TOILET - WITH TANK SINGLE FLUSH GC MANUF: PROFLO, MODEL: PF1601PAWH DATA DEVICE SCHEDULE - "A" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS AUDIO VISUAL 10015 2 SPEAKER RECESSED - WHITE VD 19493 4 SPEAKER PENDANT MOUNTED - BLACK VD DATA 20294 1 IOT MODULE SB MENU BOARD 22970 4 MENU BOARD - DIGITAL MENU BOARD - 44X25.25IN 1121X644MM - BLACK VD 22972 1 MENU - DMB SCREEN MOUNTING BRACKET VD 23021 1 MENU BOARD - ORDER STATUS BOARD MOUNTING BRACKET - BLACK VD LIGHTING FIXTURE SCHEDULE - "L" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY BULB COMMENTS PENDANT 20661 3 PENDANT - ANDLIGHT SPOTLIGHT VOLUMES - BLACK VD AS PACKAGED: 1X LED G25 6.5W (DOWN); 1X LED A15 4.5W (UP) UPLIGHT:C DOWNLIGHT:C 20662 1 PENDANT - ANDLIGHT SPOTLIGHT VOLUMES - SAGE VD INTEGRATED LED UPLIGHT:C DOWNLIGHT:B RECESSED CAN 21772 54 CAN - LED ADJUSTABLE RECESSED - 3IN 75MM - WHITE - 800LM FLOOD VD INTEGRATED LED 21774 12 CAN - LED ADJUSTABLE RECESSED - 3IN 75MM - WHITE - 700LM WF VD INTEGRATED LED 21776 6 CAN - LED WALL WASH - 3IN 75MM - WHITE - 1000LM VD INTEGRATED LED SCONCE 20748 2 SCONCE - KUZCO PLUTO TRIPLE - CHROME VD INTEGRATED LED STRIP 22215 1 STRIP - LED TAPE IN HOUSING - VARIABLE LENGTH - BLACK - 350LM PER FT VD INTEGRATED LED FIELD TRIMMABLE TO 0.9IN LENGTHS 22216 1 STRIP - LED TAPE IN HOUSING - VARIABLE LENGTH - WHITE - 350LM PER FT VD INTEGRATED LED FIELD TRIMMABLE TO 0.9IN LENGTHS 22220 4 STRIP - LED TAPE GRAZER - VARIABLE LENGTH - WHITE - 700LM PER FT VD INTEGRATED LED FIELD TRIMMABLE TO 6IN LENGTHS TRACK 19409 5 TRACK - WITH CONNECTORS - 4FT 122CM - BLACK - 2 CIRCUIT VD JUNO; TU-4FT-BL 19411 1 TRACK - WITH CONNECTORS - 8FT 244CM - BLACK - 2 CIRCUIT VD JUNO; TU-8FT-BL 21779 9 TRACK - LED FIXTURE WITH SNOOT - 3IN 75MM - BLACK - 1100LM FLOOD VD INTEGRATED LED TROFFER 21783 7 TROFFER - LED RECESSED - 24X48IN 600X1200MM - WHITE - 4300LM VD INTEGRATED LED MECHANICAL EQUIPMENT SCHEDULE - "M" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS FAN 10721 1 FAN - DT AIR CURTAIN - 22IN 560MM GC INCLUDE AS PART OF DT WINDOW PACKAGE DOOR SCHEDULE - "D" DESIGN ID MARK DESCRIPTION WIDTH HEIGHT HARDWARE SET FURN BY INST BY COMMENTS Interior 10190 09 DOOR - SINGLE FLUSH - 36IN 3' - 0" 7' - 0" 7-A GC FRAME FINISH: SW7031, DOOR FINISH: WD0073 10190 16 DOOR - SINGLE FLUSH - 36IN 3' - 0" 7' - 0" 6 GC FRAME FINISH: SW7031, DOOR FINISH: WD0073 10086 08 DOOR - SINGLE IMPACT DOUBLE ACTING - 36IN 915MM 3' - 0" 7' - 0" 11 GC FRAME FINISH: SW7103, DOOR FINISH: PL0027 3 1 Stop & Holders 473 Door Stop w/ Hook Rockwood 626 3 Accessories GJ64 Rubber Silencer Glynn Johnson Gray 2 Protective Trim Units K1050 B4E Kickplate 8" x 34" Each Side 32D Rockwood 630 1 Closing Devices 8916 Door Closer 8916 F89P Dorma 626 1 Securing Devices C607 7-Pin Core Combination "A" Keyway Falcon Lock 626 1 Alarm Lock CO-100 Privacy Keypad Schlage 626 3 Hanging Devices TA2714/MPB79 Hinge MacPro Bearing 5 x 4.5 McKinney 626 No. Item Description Manufacturer Finish DOOR HARDWARE SET NO. 7-A - For restroom door with cipher lock 1 Stops and Holders 473 Door Stop w/ Hook Rockwood 626 3 Accessories GJ64 Rubber Silencer Glynn Johnson Gray 2 Protective Trim Units K1050 B4E Kickplate 8" x 34" Each Side 32D Rockwood 630 1 Closing Devices 8916 Door Closer 8916 AF89P Dorma 689 1 Securing Devices PB5425LN Lock, Shallow Coin Turn, Privacy PB5425LN-693-497 1-3/4 Yale Lock 626 3 Hanging Items TA2714/MPB79 Hinge MacPro Bearing 5 x 4.5 McKinney 626 No. Item Description Manufacturer Finish DOOR HARDWARE SET NO. 6 - For restroom door with lever and privacy lock 1 Traffic Door Package SCP8 36" x 84" Eliason As Selected No. Item Description Manufacturer Finish DOOR HARDWARE SET NO. 11 - For workroom door at backbar WINDOW SCHEDULE DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY Finish COMMENTS WINDOW 21987 1 WINDOW - DT BI-PARTING RESTRICTED OPENING - 54X52IN - WITH AIR CURTAIN & TRANSOM GC MANUF: READY ACESS, MODEL: WC14X29131, FINISH: BLACK BARRIER FREE DOOR HARDWARE SCHEDULE - "D" DESIGN ID COUNT DESCRIPTION FURN BY INST BY COMMENTS 23130 1 DOOR - BARRIER FREE HARDWARE ACTUATOR BOLLARD VD 23131 1 DOOR - BARRIER FREE HARDWARE ACTUATOR WALL MOUNT VD 23129 1 DOOR - BARRIER FREE HARDWARE KEY SWITCH VD 23135 1 DOOR - BARRIER FREE HARDWARE OPERATOR - BLACK VD FURNITURE SCHEDULE - "F" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS CHAIR 21456 4 CHAIR - CAFE ASHER UPHOLSTERED BACK - WHITE OAK AND CARAMEL BROWN NATURAL WD0073 F0008 VD 23062 4 CHAIR - CAFE PEGGY UPHOLSTERED - WHITE OAK AND SEAFOAM GREEN WD0073 F0243 VD TK0077 1 CHAIR - MANAGERS WORKSTATION SB STEELCASE SERIES ONE ARMLESS DESK TK0053 1 DESK - MANAGERS WORKSTATION SHELVES - 48IN 1220MM SB TK0076 1 DESK - MANAGERS WORKSTATION - 48X24X27IN 1220X610X685MM SB MIRROR 10093 2 MIRROR - RESTROOM - 18X30IN 455X760MM GC TK0050 1 MIRROR - BOH - 16X51IN 405X1295MM VD OTHER 10756 2 COAT HOOK 1 PRONG SQUARE - 2IN 50MM - SST SB 19620 3 ACOUSTICAL BAFFLE SYSTEM - 106X48IN 2690X1220MM - TRAVERTINE DARK GC TRAVERTINE DARK TK0051 1 COAT HOOK STRIP - 30IN 760MM VD BLACK FINISH X19620 6 ACOUSTICAL BAFFLE SYSTEM - 106X48IN 2690X1220MM - TRAVERTINE DARK GC TRAVERTINE DARK STORAGE TK0078 1 FILE MOBILE PEDESTAL WITH CUSHION AND LOCK VD TK0079 1 MANAGERS DESK CART - 24X20IN 610X510MM VD TABLE 18468 2 TABLE - BASE CAFE T LEG - HOT ROLLED STEEL MT0011 VD 21449 5 TABLE - BASE CAFE HEIGHT BOTTLE - FLAT BLACK MT0028 SB 21474 1 TABLE - BASE ACCESSIBLE POST LEG RECTANGULAR - FLAT BLACK MT0028 VD 21788 1 TABLE - TOP ACCESSIBLE FOR POST LEG RECTANGULAR - 40X24IN 1015X610MM - WHITE OAK WD0073 VD 21800 1 TABLE - TOP ACCESSIBLE ROUND EDGE OBLONG - 48X24IN 1220X610MM - WHITE OAK WD0073 VD 21842 5 TABLE - TOP ROUND EDGE ROUND - 24IN 610MM - WHITE OAK WD0073 SB WINDOW TREATMENT X22488 8 ROLLER SHADE - U59 ALABASTER VD MANUF: ROLL-A-SHADE, MODEL: SHEER WEAVE - U59 ALABASTER GRAPHICS AND ARTWORK SCHEDULE - "G" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS GRAPHICS - ARTWORK 21491 1 ART - BRIDGET SHILLING - PICKING COFFEE VD 1’ - 10” X 2’ – 6” WOOD FRAME AROUND THE ARTWORK – WD0073. FRAME WIDTH: 3”, FRAME DEPTH: 1”. FOR MORE INFOTMATION REFER TO INTERIOR ELEVATION SHEETS. 22043 1 ART - BRIDGET SHILLING - COFFEE AND THE TANAGER VD 1’ - 10” X 2’ – 6” WOOD FRAME AROUND THE ARTWORK – WD0073. FRAME WIDTH: 3”, FRAME DEPTH: 1”. FOR MORE INFOTMATION REFER TO INTERIOR ELEVATION SHEETS. 22922 1 ART - JORDAN KAY - FRUITING COFFEE BRANCH 2 - PAINTABLE VD ARTWORK DESIGNED TO BE HAND PAINTED ON THE WOOD CLADDING. WD0073-MAD101 X22178 1 ART - MARIA CAMILA BERNAL TORO - COLOMBIA STORY VD WRAPPED CANVAS IN FLOAT FRAME 1” THICK - WD0073. REFER TO SHEET I204 FOR OVERALL DIMENSIONS. GRAPHICS - OTHER 23136 1 AUTOMATIC DOOR CAUTION SIGNAGE VD TK0074 2 RESTROOM SIGN GENDER NEUTRAL ACCESSIBLE VD EXTERIOR SIGNAGE SCHEDULE - "S" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY BULB COMMENTS SIGNAGE - DRIVE THRU 22544 1 SIGN - DT CLEARANCE BAR SQUARE FRAME FREESTANDING - BLACK AND DARK GREEN VD 23071 1 SIGN - DIRECTIONAL EXIT ONLY ILLUM DS - EXG FOUNDATION - 44IN 1120MM VD 23077 2 SIGN - DT DIRECTIONAL ARROW ILLUM DS - EXG FOUNDATION - 44IN 1120MM VD SITE SCHEDULE - "Y" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS FENCE AND RAILING 19581 1 QUEUE RAIL WOOD DOUBLE - WHITE OAK WD0073 VD OTHER 23113 1 GROUND GRAPHICS DT ENTRY STENCIL VD REFERENCE PAINT 20511 FOR SPECIFICATIONS 23115 1 GROUND GRAPHICS DO NOT ENTER STENCIL VD REFERENCE PAINT 20511 FOR SPECIFICATIONS 23117 8 GROUND GRAPHICS ARROW STENCIL VD REFERENCE PAINT 20511 FOR SPECIFICATIONS FRAME FINISH: SW7741, DOOR FINISH: WD0073 Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments A 2301 N Tustin Ave #A8/22/2024 STATE OF CALIF RNIA O REN.09/30/25 S LICEN D ARCHITECT E H I DENO R I I WAGAM I C-34970 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 7/ 5 / 2 0 2 4 1 0 : 2 3 : 1 4 A M W: \ P r o j e c t s \ S t a r b u c k s \ T u s t i n & S a n t a C l a r a 5 1 9 6 9 \ C D \T u s t i n a n d S a n t a C l a r a - R e v i t M o d e l . r v t I602 76085-018 07-02-2024 TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES INTERIOR FINISHES SCHEDULES 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 CASEWORK FINISH SCHEDULE ENGINE ZONE MATERIAL DESCRIPTION FINISH CODE COMMENTS COMPOSITE - WHISPER COUNTERTOPS - BACKBAR COMPOSITE - WHISPER CP0030 COUNTERTOPS - ESPRESSO COMPOSITE - WHISPER CP0030 COUNTERTOPS - FRONTBAR COMPOSITE - WHISPER CP0030 COUNTERTOPS - SHROUD COMPOSITE - WHISPER CP0030 METAL - FLAT BLACK POWDERCOAT CABINETS - DOOR PULL METAL - FLAT BLACK POWDERCOAT MT0028 METAL - STAINLESS STEEL - BRUSHED COUNTERTOPS - HAND SINK METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED 16GA PLAM - GOLDEN BLONDE GRAIN CABINETS - UPPER PLAM - GOLDEN BLONDE GRAIN PL0027 PLAM - GRAPHITE CABINETS - UNDERCOUNTER PLAM - GRAPHITE PL0003 CABINETS - UPPER PLAM - GRAPHITE PL0003 WOOD - WHITE OAK - FLUTED - VERTICAL FINISH PANELS - FRONTBAR WOOD - WHITE OAK - FLUTED - VERTICAL WD0073 MAD303-V CASEWORK SCHEDULE - "C" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS X1002 1 PARTNER REST AREA - UPPER CUBBIES - PL0027 CW X1005 1 1/8" X 1/8" METAL TRIM - MT0029 CW X1007 1 WOOD CLADDING - WD0073/MAD 101 CW X1009 1 1"X1" METAL TRIM - MT0029 CW BANQUETTE TK0001 4 BANQUETTE - ORION CW REFER TO SHEET I502C FOR DIMENSIONS - FABRIC: F0243, BASE MATERIAL: MT0028 TKX001 1 BANQUETTE - ORION - CORNER CW GC REFER TO SHEET I502C FOR DIMENSIONS - FABRIC: F0243, BASE MATERIAL: MT0028 CABINET 17573 6 CABINET - BACKBAR COUNTER SUPPORT PANEL - 3IN 75MM CW 17574 3 CABINET - BACKBAR SINK OR ICE - 15IN 380MM CW 17740 2 CABINET - BACKBAR - 30IN 760MM CW 17741 4 CABINET - BACKBAR 15IN 380MM CW 17743 1 CABINET - DT POS - 30IN 760MM CW 17744 1 CABINET - FRONTBAR POS BRIDGE - 22IN 560MM CW 17745 1 CABINET - BACKBAR DRAWER - 15IN 380MM CW 17747 6 CABINET - BACKBAR TRASH - 15IN 380MM CW 17896 1 CABINET - BACKBAR CUBBY - 15IN 380MM CW 19343 1 CABINET - CORNER FIT KIT CW 21190 1 CABINET - FRONTBAR TRASH - 15IN 380MM CW 21191 3 CABINET - FRONTBAR DRAWER - 15IN 380MM CW 21192 2 CABINET - FRONTBAR POS - 30IN 760MM CW 23388 1 CABINET - BACKBAR - 18IN 460MM CW 23426 1 CABINET - WRM LOW - 30IN 760MM CW X17741 3 CABINET - BACKBAR 15IN 380MM CW CABINETS X23709 1 CABINET - CBE UPPER CASEWORK IN-LINE - LF - 82IN CW CAFE 20369 1 WALL BAY 3 UNIT - 90IN 2285MM - WHITE OAK WD0073 VD 23964 1 WASTE AND RECYCLE STATION THREE DROP - GOLDEN BLONDE AND WHITE PL0027 CP0002 SB COUNTERTOP 17807 2 COUNTERTOP - BACKBAR - 15IN 380MM CW 17810 2 COUNTERTOP - HAND SINK WITH TALL SPLASH STAINLESS - 15IN 380MM CW 17830 1 COUNTERTOP - POS - 82IN 2085MM CW 18720 1 COUNTERTOP - BREW WITH TRASH DROP - LF - 90IN 2285MM CW 18883 1 COUNTERTOP - END CAP SQUARED - RF CW 20061 1 COUNTERTOP - ESPRESSO METRO - RF - 139IN 3530MM CW 20063 1 COUNTERTOP - FRONTBAR CAP - 139IN 3530MM CW 20271 1 COUNTERTOP - FRONTBAR MOP PLANAR - 60IN 1525MM CW 21958 1 COUNTERTOP - DT WARMING - RF - 93IN 2360MM CW 23151 1 COUNTERTOP - PARTNER AMENITY - 67IN 1700MM CW 23409 1 COUNTERTOP - CBE IN-LINE LF - 138IN 3505MM CW 23433 1 COUNTERTOP - WRM RF - 79IN 1930MM CW X17827 1 COUNTERTOP - DT POS - RF - 78IN 1980MM CW DIEWALL 17831 1 DIEWALL - POS - 82IN 2085MM CW 18865 1 DIEWALL - 60IN 1525MM CW 18884 1 DIEWALL - END CAP - RF CW 20064 1 DIEWALL - ESPRESSO - 139IN 3530MM CW FIT KIT 17894 3 FIT KIT - CABINET FILLER PANEL CW X17895 1 FIT KIT - BACKBAR COUNTERTOP CW OTHER 11155 2 ESPRESSO MACHINE PUMP MOUNT - 10X10IN 255X255MM CW 18145 4 COUNTERTOP SUPPORT LEG CW 20066 1 SHROUD - 139IN 3530MM CW 20067 1 SNEEZE GUARD - 139IN 3530MM CW 20633 5 COUNTERTOP SUPPORT LEG SLIM CW PANEL 17832 1 PANEL - 82IN 2085MM CW 18717 1 PANEL - 60IN 1525MM CW 18885 1 PANEL - END CAP - RF CW 20065 1 PANEL - 139IN 3530MM CW UPPER CUBBY X0017 1 DRIVE-THRU UPPER CABINET - ALT 3 CW WALL TREATMENT (AREA) SCHEDULE - "Q" DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS 17778 110 SF WALL TEXTURE - TEXTURGLAS - TG21 HERRINGBONE + SW7741 VD DESIGNER TO SPECIFY PAINT COLOR 17778 157 SF WALL TEXTURE - TEXTURGLAS - TG21 HERRINGBONE + SW7749 VD DESIGNER TO SPECIFY PAINT COLOR PLASTIC 11469 1319 SF FRP - WHITE GC TILE 22817 718 SF TILE - MOSA - UNBLEACHED WHITE - 4X12IN 100X300MM VD GROUT: MAPEI - 11 SAHARA BEIGE, OR EQUAL FLOOR TREATMENT SCHEDULE - "T" DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS PLASTIC 19795 897 SF POLYVINYL FLOOR TILE - ECO-GRIP - PEWTER GC GC TO PROCURE FROM ALLIED INDUSTRIES TILE 20259 269 SF TILE - VENICE VILLA - IVORY - 24X24IN 600X600MM VD GROUT: MAPEI - 44 PALE UMBER, OR EQUAL 20262 561 SF TILE - FRENCH CLAY - CAFE - 24X24IN 600X600MM VD GROUT: MAPEI - 09 GREY, OR EQUAL WALK OFF MAT 19288 7 SF WALK OFF MAT - HELIX Z1 - BLACK - 12X9IN 305X230MM VD 19289 17 SF WALK OFF MAT - HELIX Z2 - BLACK AND GUNMETAL - 12X9IN 305X230MM VD CANNOT BE CUT TO SIZE; USE HELIX Z1 AS BORDER WHEN FULL TILES CANNOT BE PLACED WALL BASE SCHEDULE - "B" DESIGN ID LENGTH DESCRIPTION FURN. BY INST. BY COMMENTS TILE BASE 18735 192' - 4" TILE BASE - PLAZA NOVA - WHITE IMAGE - 6X12IN 150X300MM VD GROUT: DESIGN TO SPECIFY X19795 306' - 10 3/4" ECOGRIP 6" BASE GC POLYVINYL ECOGRIP FLOORING TO WRAP UP 6" ON WALLS AND CABINETS WITH 3/8" COVE RADIUS AND HEAT WELDED SEAMS PAINT SCHEDULE DESIGN ID DESCRIPTION LRV FURN. BY INST. BY COMMENTS SW7031 SW7031 MEGA GREIG 37 GC SW USE PRIMER CP-1; NCS - S 3005-Y50R; AKZO NOBEL - 20YY 37/094 SW7103 SW7103 WHITETAIL 86 GC SW USE PRIMER CP-2; NCS - S 6005-G80Y; AKZO NOBEL - 30YY 14/070 SW7741 SW7741 WILLOW TREE 41 GC SW7749 SW7749 LAUREL WOODS 6 GC DESIGNER TO SPECIFY PAINT COLOR CEILING TREATMENT SCHEDULE - "U" DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS MISCELLANEOUS 11302 476 SF ACT VlNYL - 2' X 4' GC MANUF: ARMSTRONG, MODEL: CLEANROOM VL-870 SITE SCHEDULE - "Y" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS FENCE AND RAILING 19581 1 QUEUE RAIL WOOD DOUBLE - WHITE OAK WD0073 VD OTHER 23113 1 GROUND GRAPHICS DT ENTRY STENCIL VD REFERENCE PAINT 20511 FOR SPECIFICATIONS 23115 1 GROUND GRAPHICS DO NOT ENTER STENCIL VD REFERENCE PAINT 20511 FOR SPECIFICATIONS 23117 8 GROUND GRAPHICS ARROW STENCIL VD REFERENCE PAINT 20511 FOR SPECIFICATIONS Revision Schedule Rev Date By Description A 06-13-24 SS 1st Round Comments A 2301 N Tustin Ave #A8/22/2024 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 76085-018 <XX-XX-XXXX> TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 Revision Schedule Rev Date By Description E001 ELECTRICAL NOTES SECURITY SYSTEM NOTES A.STARBUCKS CONTRACTS DIRECTLY WITH SECURITY VENDOR TO SUPPLY AND INSTALL THE SECURITY SYSTEM. CONTRACTOR TO SCHEDULE INSTALLATION OF SECURITY SYSTEM FOR FOUR (4) TIMES; 1.MEET TO PLAN SECURITY CABLE PULL WITH SECURITY CABLE INSTALLER PRIOR TO DRYWALL INSTALLATION. 2.SECURITY CABLE INSTALLER PULLS SECURITY CABLES, MOUNTS PANEL, KEYPAD AND SENSORS. 3.SECURITY EQUIPMENT INSTALL OF CAMERA, NVR AND MONITOR. 4.SECURITY MONITORING COMPANY TO BRING SYSTEM ONLINE AND TRAIN PARTNERS AFTER POS INSTALL B.SECURITY VENDOR REQUIRES A MINIMUM TWO (2) WEEKS LEAD TIME FOR EACH INSTALLATION. SECURITY VENDOR WILL COORDINATE REGIONAL INSTALLERS. ALL ADDITIONAL EXPENSES INCURRED DUE TO THE CONTRACTOR'S FAILURE TO SCHEDULE ACCORDINGLY WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. TELEPHONE SYSTEM NOTES A.IF ADDITIONAL TELEPHONE LINES ARE REQUIRED BEYOND THE STANDARD SINGLE LINE (SUCH AS FOR A FIRE ALARM) THE GENERAL CONTRACTOR SHALL CONTACT STARBUCKS PRIOR TO BEGINNING CONSTRUCTION TO ORDER THE ADDITIONAL TELEPHONE LINE(S). REPORT ANY TELEPHONE INSTALLATION ISSUES IMMEDIATELY TO STARBUCKS. B.CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT THERE ARE EXISTING, WORKING TEL FACILITIES TO THE BUILDING OR THAT LANDLORD HAS FURNISHED AND INSTALLED ONE (1) 2" (51MM) MIN. (ENTRANCE) CONDUIT INCLUDING PULL STRING FROM TELCO STREET FEED LINE TO THE BUILDING AS IDENTIFIED BY THE PHONE COMPANY. NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY IF FACILITIES OR CONDUIT AND PULL STRING ARE NOT INSTALLED. C.GENERAL CONTRACTOR IS TO ENSURE THAT THERE IS A 2" (51MM) MIN. CONDUIT WITH PULL STRING FROM THE DATA RACK TO THE DEMARC (TELCO TO CUSTOMER HAND OFF EQUIPMENT) WHEN THE DEMARC IS MORE THAN 10' FROM THE DATA RACK. DISTANCES LESS THAN 10' WILL NOT REQUIRE CONDUIT. D.ALL TELEPHONE/NETWORK CABLING IS THE SCOPE OF WORK OF THE TELEPHONE/ NETWORK CABLING VENDOR. POS/ DATA LINE NOTES A.STARBUCKS CONTRACTS DIRECTLY WITH THE DATA CABLING VENDOR TO SUPPLY AND INSTALL CATEGORY 5e (CAT5e) LAN CABLE AND CONNECTORS FOR THE POINT OF SALE (POS) SYSTEMS. CONTRACTOR TO SCHEDULE INSTALLATION OF DATA CABLING WITH DATA CABLING VENDOR. DATA CABLING VENDOR REQUIRES A LEAD TIME FOR INSTALLATION. DATA CABLING VENDOR WILL COORDINATE REGIONAL INSTALLERS. B.AT THE START OF CONSTRUCTION, STARBUCKS CONSTRUCTION MANAGER SCHEDULES DELIVER OF CASH REGISTER/MANAGER'S WORKSTATION EQUIPMENT AND INSTALLATION BY A POS INSTALL TECHNICIAN FOR ONE (1) MONTH PRIOR TO STORE OPEN. CONTRACTOR TO VERIFY DELIVERY SCHEDULE TWO (2) WEEKS PRIOR TO DELIVERY AND INSTALLATION DATE. EQUIPMENT IS SHIPPED DIRECTLY TO THE STORE. CONTRACTOR TO ACCEPT POS EQUIPMENT DELIVERY. DO NOT REFUSE DELIVERY. C.DATA CABLING TECHNICIAN TO PROVIDE ALL CAT5e LAN CABLING AND CONNECTORS FROM ALL DESIGNED AND FUTURE CASH REGISTER LOCATIONS, MANAGER'S WORKSTATION, ALL OTHER NETWORKED EQUIPMENT (CUP LABELERS, CLOVER, BUMP BAR, ETC...) AND WIRELESS ACCESS POINT TO THE DATA RACK AREA. CONTRACTOR IS TO HAVE CONDUIT WITH PULL STRING IN PLACE FOR ALL CABLE RUNS PRIOR TO CABLE INSTALL DATE. D.STARBUCKS NEW STORE GROUP IS RESPONSIBLE FOR COORDINATING STARBUCKS POS SYSTEMS DELIVERY AND INSTALLATION WITH THE POS VENDOR. THIS GROUP MAY BE CONTACTED AT: NEWSTORES@STARBUCKS.COM. COMMUNICATION SYSTEM NOTES A.CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT THE LANDLORD HAS FURNISHED AND INSTALLED ONE (1) ADDITIONAL 2" (51MM) (ENTRANCE) CONDUIT INCLUDING PULL STRING (FOR A TOTAL OF TWO (2)) FROM THE STREET FEED TO THE BUILDING AS IDENTIFIED BY THE INTERNET SERVICE PROVIDER. FIRE ALARM SYSTEM NOTES A.IF STARBUCKS IS REQUIRED TO PROVIDE A FIRE ALARM AND/OR FIRE ALARM MONITORING AND/OR PHONE LINES FOR A FIRE ALARM, AS SPECIFIED IN THE LEASE AGREEMENT, THE CONTRACTOR IS TO NOTIFY GNOC IMMEDIATELY THAT FIRE ALARM LINES ARE NEEDED. STARBUCKS PREFERRED FIRE ALARM SERVICE PROVIDER, STANLEY, IS TO BE CONTACTED BY THE CONSTRUCTION MANAGER TO INSTALL FIRE ALARM PANEL AND/OR MONITORING SERVICE AS REQUIRED. WIRELESS NETWORK NOTES A.CABLING FOR INTERNET SERVICE SHALL BE FURNISHED AND INSTALLED BY THE VENDOR FOR FIBER OR BROADBAND CONNECTIONS. T1 AND ETHERNET EXTENSION CABLING IS PROVIDED BY THE STARBUCKS (TELEPHONE/ NETWORK) CABLING VENDOR. COORDINATE WITH STARBUCKS. MUSIC SYSTEM NOTES A.PROVIDE AND INSTALL A COMPLETE WIRING SYSTEM FOR ALL SPEAKERS. CONNECT ALL SPEAKERS TO THE OWNER PROVIDED MUSIC SYSTEM. MOUNT OWNER FURNISHED SPEAKERS WHERE SHOWN ON INTERIOR REFLECTED CEILING PLAN AND IN COORDINATION WITH ALL PLANS AND DETAILS. FOLLOW MANUFACTURER'S INSTALLATION REQUIREMENTS. CONTROLS AND OPERATION A.COORDINATE INSTALLATION OF LIGHTING CONTROL PANEL (IF APPLICABLE) AND ENERGY MANAGEMENT SYSTEM (EMS) WITH ENERGY MANAGEMENT SYSTEM VENDOR. B.FURNISH AND INSTALL RACEWAYS WITH PULLSTRINGS AND JUNCTION BOXES TO SUPPORT VENDOR’S WORK. C.COORDINATE WITH VENDOR AND PLANS FOR DEVICE LOCATIONS. GENERAL ELECTRICAL NOTES A.THE ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL WORK AND SPECIFICATIONS WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOT SCALE DISTANCES OFF THE ELECTRICAL DRAWINGS; USE ACTUAL BUILDING DIMENSIONS. OVERALL CASEWORK COMPONENT DIMENSIONING ON ELECTRICAL DETAILS ARE SHOWN FOR REFERENCE AND COORDINATION ONLY. SEE SPECIFICATION SHEETS FOR ELECTRICAL SPECIFICATIONS. B.ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE ALL BRANCH CIRCUIT LOADS BETWEEN THE PHASES OF THE SYSTEM WITHIN 10% OF THE HIGHEST PHASE LOAD IN EACH PANEL BOARD. C.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DE-ENERGIZING CIRCUITS IN DEMOLITION AREAS TO INSURE A SAFE CONDITION. ELECTRICAL DEVICES AND ASSOCIATED WIRING LOCATED WITHIN THE DEMOLITION AREA THAT WILL NO LONGER BE USED SHALL BE REMOVED AND PROPERLY DISPOSED OF AT CONTRACTORS EXPENSE UNLESS OTHERWISE NOTED. D.THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALL ELECTRICAL SYSTEM OUTAGES WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED OTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN 11:00PM AND 5:00AM. E.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY CONDUIT AND J-BOXES TO SUPPORT A COMPLETE SECURITY, PHONE, POS AND DATA SYSTEMS. SEE MANAGER WORKSTATION AND BAR POINT OF SALE (POS) POWER/TELECOM/SECURITY DIAGRAM. COORDINATE ALL DEVICE LOCATIONS AND MOUNTING HEIGHTS WITH SECURITY VENDOR PRIOR TO ROUGH-IN. PROVIDE END-TO-END PULL STRINGS IN ALL CONDUITS. LABEL EACH END OF THE PULL STRING WITH CONDUIT SYSTEM ("SECURITY") AND DESTINATION ("CAFÉ", "FRONT BAR", ETC.). PROVIDE INSULATED BUSHINGS ON ALL STUBBED-UP AND EXPOSED CONDUIT ENDS. F.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF WORK. G.EXPOSED/SURFACE MOUNTED CONDUITS SHALL ONLY BE ALLOWED WHERE NECESSARY IN EXPOSED CEILING AREAS. IF CONDUITS NEED TO BE SURFACE MOUNTED TO WALLS, COORDINATE WITH STARBUCKS CONSTRUCTION MANAGER FOR APPROVAL. H.VERIFY LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECTURAL DRAWINGS, INTERIOR DETAILS, FINISH SCHEDULES, GENERAL CONTRACTOR, EQUIPMENT VENDORS, STARBUCKS AND EXISTING SITE CONDITIONS. VERIFY FINAL DOOR HINGE LOCATION PRIOR TO SWITCH INSTALLATION AND ADJUST SWITCH LOCATION IF NEEDED. DO NOT MOUNT RECEPTACLES/SWITCHES IN LOCATIONS THAT WOULD CONFLICT WITH MIRRORS, SEAMS OF WALLS, WAINSCOTS, TILE TRANSITIONS, ETC. GENERAL NOTES SCOPE THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. SITE EXAMINATION THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF CSA, ULC, NEC, ASTM, UL, ETL, NEMA, ANSI, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE CODES, THE HIGHEST STANDARD SHALL APPLY. ELECTRICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS. PERMITS AND FEES THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL WORK. WARRANTY THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. STANDARD ABBREVIATIONS AFF AHJ APPROX ABOVE FINISHED FLOOR AUTHORITIES HAVING JURISDICTION APPROXIMATE BLDG BUILDING CKT CLG CM CONST CW CXA CIRCUIT CEILING STARBUCKS CONSTRUCTION MANAGER CONSTRUCTION COLD WATER COMMISSIONING AGENT DEG DL DM DN DTL DWG(S) DEGREES LIGHTS WITHIN DAYLIGHT ZONE STARBUCKS DESIGN MANAGER DOWN DETAIL DRAWING(S) EA EC ECP EG ELEC EM EMS EXIST EXT EACH ELECTRICAL CONTRACTOR EQUIPMENT CONTROL PAC EXHAUST GRILLE ELECTRICAL EMERGENCY ENERGY MANAGEMENT SYSTEM EXISTING EXTERIOR F&I FLR FT FURNISH & INSTALL FLOOR FOOT/FEET GC GFCI GND GENERAL CONTRACTOR GROUND FAULT CIRCUIT INTERRUPTER GROUND HR HVAC HW HOUR HEATING, VENTILATION, AIR CONDITIONING HOT WATER LCP LL LS LV LIGHTING CONTROL PANEL LANDLORD LIGHT SENSOR PHOTOCELL LOW VOLTAGE MAX MC MDP MECH MEP MFG MIN MAXIMUM MECHANICAL CONTRACTOR MAIN DISTRIBUTION PANEL MECHANICAL MECHANICAL, ELECTRICAL, AND PLUMBING MANUFACTURER MINIMUM NL NTS NIGHTLIGHT NOT TO SCALE OCP OVERCURRENT PROTECTION REF REQ(’D) REV REFERENCE REQUIRE(D) REVISION SF SHT SPECS SST SQUARE FEET SHEET SPECIFICATION(S) STAINLESS STEEL TEL TEMP TYP TELEPHONE TEMPORARY TYPICAL UNO UNLESS NOTED OTHERWISE WH WP WATER HEATER WEATHER PROOF ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION POWER DUPLEX RECEPTACLE, WALL MOUNTED DUPLEX RECEPTACLE, WALL MOUNTED, SPLIT-WIRED OCCUPANCY SENSOR CONTROLLED/SWITCHED DUPLEX RECEPTACLE, WALL MOUNTED, ISOLATED GROUND DUPLEX RECEPTACLE, WALL MOUNTED ABOVE COUNTER DUPLEX GFCI RECEPTACLE, WALL MOUNTED DUPLEX GFCI RECEPTACLE, WALL MOUNTED ABOVE COUNTER DUPLEX RECEPTACLE, WALL MOUNTED WITH TWO 5V USB CHARGING PORTS DOUBLE DUPLEX RECEPTACLE, WALL MOUNTED DOUBLE DUPLEX GFCI RECEPTACLE, WALL MOUNTED DUPLEX RECEPTACLE, FLUSH IN CEILING SPECIAL OUTLET: 20A, 250V, 2P, 3-WIRE NEMA 6-20R SPECIAL OUTLET: 30A, 125V, 1P, 3-WIRE NEMA 5-30R SPECIAL OUTLET: 30A, 250V, 2P, 3-WIRE NEMA 6-30R SPECIAL OUTLET: 50A, 250V, 2P, 3-WIRE NEMA 6-50R SPECIAL OUTLET: 50A, 250V, 3P, 4-WIRE NEMA 14-50R SPECIAL OUTLET: 50A, 250V, 3-PHASE, 4-WIRE NEMA 15-50R JUNCTION BOX JUNCTION BOX - WALL MOUNTED JUNCTION BOX MOUNTED IN ACCESSIBLE CEILING SPACE. MOUNT FLUSH IN FLOOR WHEN INDICATED IN A FLOOR BOX SYMBOL. NON-FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH MOTOR. NUMBER INDICATES HORSEPOWER RATING FOR 1HP AND LARGER MOTOR. "F" INDICATES FRACTIONAL HORSEPOWER TRACK CURRENT LIMITER. "#" DENOTES AMPS RATING. POWER SUPPLY/DRIVER, CLASS 2 FOR LED FLOOR BOX SPECIFICATIONS SINGLE SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. WIREMOLD RFB2-OG/FPCTC WHEN SHOWN IN ON-GRADE WIRE MOLD 6ATCP, 6ATP, OR 6ATCPAV AS REQUIRED WHEN SHOWN IN ABOVE GRADE. TWO SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. WIREMOLD RFB2-OG/FPCTC WHEN SHOWN IN ON-GRADE WIRE MOLD 6ATCP, 6ATP, OR 6ATCPAV AS REQUIRED WHEN SHOWN IN ABOVE GRADE. SIGNAL TELEPHONE OUTLET DATA OUTLET COMBINATION TELEPHONE/COMPUTER OUTLET LIGHTING CONTROL SYMBOLS SINGLE POLE SWITCH, 20A, 120/277V or CAT5e WIRED WALL SWITCH TO BE USED WITH NON-DIMMING POWER/RELAY PACK LOW VOLTAGE (0-10V) WALL MOUNTED SWITCH FOR MANUAL ON/OFF AND DIMMING (STEPPED/CONTINUOUS) CONTROL OF LIGHTING. "a" INDICATES ZONE WHERE SHOWN ON DRAWINGS. OCCUPANCY SENSOR - WALL MOUNTED. "a" INDICATES CONTROLLED ZONE. SEE CONTROL CONFIGURATIONS FOR MORE INFORMATION. OCCUPANCY SENSOR w/ DIMMER - WALL MOUNTED. "a" INDICATES CONTROLLED ZONE. SEE CONTROL CONFIGURATIONS FOR MORE INFORMATION. 1-WAY/2-WAY DIRECTIONAL CEILING MOUNTED, NON-NETWORKED/ INTERCONNECTED/ NETWORKED, SYSTEM-BASED OCCUPANCY SENSOR. QUANTITY OF ADJACENT LOWER CASE LETTERS INDICATES QUANTITY OF RELAYS/DIMMING CIRCUITS REQUIRED - SEE CONTROL CONFIGURATIONS BELOW FOR MORE INFORMATION. EXACT CONTROL FUNCTION IS DETERMINED BY THE BALLAST/FIXTURE TYPE. AUTOMATIC CONTINUOUS DIMMING DAYLIGHTING CONTROLLER USED TO DIM LIGHTS WHEN SUFFICIENT NATURAL LIGHT IS PRESENT. NUMBER IN PARENTHESIS INDICATES THE AVERAGE WORKPLANE "TARGET ILLUMINATION" SYMBOL VALUE. ADJACENT LOWER CASE LETTER(S) INDICATES SWITCH LEG(S) CONTROLLED. ADJACENT "+, ++ AND *" INDICATES PORTION OF SWITCH LEG CONTROLLED BY SENSOR WHERE "+" INDICATES PRIMARY SIDELIT DAYLIT ZONE, "++" INDICATES SECONDARY SIDELIT DAYLIT ZONE, AND "*" INDICATES SKYLIT DAYLIT ZONE. CONTROL CONFIGURATIONS y "y" INDICATES THAT SWITCH LEG "y" TO BE CONFIGURED IN A "AUTO ON 100% / AUTO OFF" AND BE CONTROLLED (CONTINUOUSLY DIMMED) BY THE ASSOCIATED CEILING SENSOR REMOTE SWITCH ON THE WALL. y,(y)"y,(y)" INDICATES THAT SWITCH LEG "y" TO BE CONFIGURED IN A "AUTO ON 50% / MANUAL ON 100% / AUTO OFF" AND BE CONTROLLED (CONTINUOUSLY DIMMED) BY THE ASSOCIATED DISTRIBUTED LIGHTING CONTROLS. (y)"(y)" INDICATES THAT SWITCH LEG "y" IS TO BE CONFIGURED IN A "MANUAL ON / AUTO OFF" (VACANCY SENSOR) AND BE CONTROLLED BY THE ASSOCIATED DISTRIBUTED LIGHTING CONTROLS. J J J 30/1 30/3RF 5 F y,(y) (40) y+,y++ APPLICABLE CODES 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA FIRE CODE 2022 NATIONAL FIRE ALARM AND SIGNALING CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC) ALLOWED SPECIFICATIONS DEVIATIONS THE FOLLOWING ITEM(S) ARE ALLOWED DEVIATIONS FROM THE DRAWINGS AND SPECIFICATIONS. THESE DEVIATIONS ARE AT THE DIRECTION OF THE OWNER. NONE SCOPE OF WORK ELECTRICAL DESIGN FOR RETAIL AND BACKBAR RENOVATION. DEFERRED APPROVAL A.FIRE ALARM SYSTEM SHALL BE UNDER SEPARATE PERMIT. SEPARATE PLANS SHALL BE SUBMITTED FOR APPROVAL BY A FIRE ALARM ENGINEER AND ALL PERMITS, INSPECTIONS AND APPROVALS SHALL BE OBTAINED FROM THE FIRE DEPARTMENT HAVING JURISDICTION. B.VIA SEPARATE SUBMITTAL BY SIGN CONTRACTOR, OBTAIN APPROVALS AND PERMITS FOR ALL SIGNS INCLUDING SIGN LIGHTING CERTIFICATE OF COMPLIANCE. C.VIA SEPARATE SUBMITTAL, OBTAIN APPROVALS AND PERMITS FOR ALL ELECTRICAL SUBSYSTEMS WITH POWER SUPPLIES OF MORE THAN 50 VA AND/OR 250 VOLTS [E.G. SECURITY, TELCO/DATA, P.A, AUDIOVISUAL, HVAC CONTROLS, ETC.] DEMOLITION AND REWIRING SYMBOLS "E"ADJACENT TO LIGHT FIXTURE OR OUTLET SYMBOL OR IN CONDUIT RUN INDICATES EXISTING TO REMAIN. EXISTING CONDUCTORS TO REMAIN UNLESS OTHERWISE NOTED ON DRAWINGS. "EX"IN CONDUIT RUN INDICATES EXISTING CONDUIT RUN TO BE REWIRED. PULL OUT EXISTING WIRES AND INSTALL NEW WIRES, QUANTITY AS INDICATED BY HASH MARKS. REFER TO PLANS FOR WIRING REQUIREMENTS. PROVIDE OTHER SYSTEM CONDUCTORS PER SPECIFICATIONS. "EA"ADJACENT TO LIGHT FIXTURE OR OUTLET SYMBOL OR IN CONDUIT RUN INDICATES EXISTING TO BE ABANDONED. REMOVE DEVICE AND INSTALL BLANK PLATE AND PULL WIRES FROM CONDUIT AS REQUIRED. "R"ADJACENT TO LIGHT FIXTURE OR OUTLET SYMBOL OR IN CONDUIT RUN INDICATES EXISTING TO BE REMOVED. EXISTING CONDUIT AND WIRE TO BE COMPLETELY DISCONNECTED AND REMOVED BACK TO LAST REMAINING OUTLET OR DEVICE. "RR"ADJACENT TO ELECTRICAL OUTLET, EQUIPMENT, ETC. INDICATES EXISTING TO BE REMOVED AND REPLACE WITH NEW. "RL"ADJACENT TO ELECTRICAL OUTLET, EQUIPMENT, ETC. INDICATES EXISTING TO BE REMOVED AND RELOCATED. "R-X-E" "E-X-R" “X” INDICATES APPROXIMATE POINT OF INTERCEPTION OF EXISTING CONDUIT RUN. CONDUIT TO BE REMOVED AT “R” SIDE OF “X”. REMOVE ALL CONDUCTORS PRIOR TO CUTTING CONDUIT. EXACT LOCATION OF ALL CONDUITS SHALL BE FIELD VERIFIED. EXTEND CONDUIT AND WIRES TO MATCH EXISTING OR AS INDICATED ON PLANS. PROVIDE PULL BOX SIZE PER CEC REQUIREMENT. STAMP DATE: 04/13/2024 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 76085-018 <XX-XX-XXXX> TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 Revision Schedule Rev Date By Description E002 ELECTRICAL SPECIFICATIONS PART I - GENERAL A. CONDITIONS 1.Furnish and install a completely wired and operational electrical system as shown on the drawings and specified herein, including but not limited to, these major items. 1.1.Lighting fixtures as indicated and specified on the plans. 1.2.Electrical panels, service, conduit, wiring, etc., for all outlets and equipment. 1.3.Telephone outlets and conduit as indicated. B. RELATED WORKS 1.The Electrical Contractor shall provide conduit, trench, and backfill for electrical service entrance from the main service to utility point of electrical service. Electrical Contractor shall coordinate the installation of the electrical service entrance with serving utility company. 2.The Electrical Contractor shall provide conduit, trench, and backfill for primary phone and CATV service from the telephone terminal board or cabinet to the phone company and CATV company point of service. C. CODES, REGULATIONS, AND STANDARDS 1.The installation shall comply with applicable local and state codes and ordinances, with the regulations of the currently accepted edition of the National Electric Code and with the requirements of the power, telephone, and CATV companies furnishing services to this installation. 2.The following industry standards, specifications, and codes are minimum requirements: 2.1.The National Electrical Code (NEC), including local amendments. 2.2.Underwriter Laboratories (UL) incorporated standards. 2.3.American National Standards Institute (ANSI). D. INSPECTION OF SITE 1.Prior to submitting a bid for electrical work, the contractor shall visit the site of the proposed construction and shall thoroughly acquaint himself with existing utilities, and working conditions to be encountered, etc. Allowance will not be made for noncompliance with this condition after bidding. 2.Electrical installation shall meet the existing conditions. E. STORAGE AND HANDLING OF MATERIALS 1.Deliver materials and equipment to the project in the manufacturer's original, unopened, labeled containers. Protect against moisture, tampering, or damage from improper handling or storage. Contractor shall protect and be responsible for any damage to work or materials until final acceptance by the owner, and shall make good without cost to the owner, any damage or loss that may occur during this period. 2.Arrange for timely delivery of materials and equipment to the job site in order to minimize the length of time between delivery and installation. 3.Cover and protect any material which may be affected by the weather while in transit or stored at the project site. Any material found defective or not installed in accordance with the contract documents may be rejected by the engineer. F. CLEANUP 1.Keep the premises free from accumulation of waste materials, or rubbish caused by employees or work under this division of the specifications. At the completion of the work remove all surplus materials, tools, etc., and leave the premises broom-clean. H. DRAWINGS 1.The drawings indicate the general arrangement and locations of the electrical work data presented on these drawings are as accurate as planning can determine, but field verification of all dimensions, locations, levels, etc., to suit field conditions is required. Review all architectural, structural, and mechanical drawings and adjust all work to meet the requirements of conditions shown. The architectural drawings shall take precedence over all other drawings. Discrepancies between different plans, or between drawings and specifications, or regulations and codes governing the installation shall be brought to the attention of the engineer in writing before the date of bid opening. If discrepancies are not reported, the Contractor shall bid the greater quantity or better quality, and appropriate adjustments will be made after contract award. Contractor shall be responsible to field measure and confirm mounting heights and location of electrical equipment with respect to counters, radiation, etc. Do not scale distances off the electrical drawings, use actual building dimensions. I. EXCAVATION, CUTTING, AND FITTING 1.Perform the excavation, cutting, fitting, repairing, and finishing of the work necessary for the installation of the equipment of this section. However, no cutting of the work of other trades or of any structural members shall be done without the consent of the architect. J. COOPERATION WITH OTHER CONTRACTORS 1.Cooperate with the other trades so that the installation of the electrical outlets and equipment will be properly coordinated. Conduit, lighting fixtures, and other equipment locations shall be checked with other trades to avoid conflict with the piping, ductwork, steel, beams, or other obstructions. Carefully check the locations of the outlet boxes and determine that they have not been disturbed during the installation of materials of other trades. 2.Coordinate the location of the trenches and conduits for electrical and telephone utility services with the general contractor. 3.Coordinate HVAC equipment connection requirements with HVAC contractor. PART II - PRODUCTS AND EXECUTION A. MATERIALS 1.All materials shall be new and of quality as specified on the plans or specifications and must carry the Underwriter's Laboratories approval covering the purpose for which they are used, in addition to meeting all requirements of the current applicable codes and regulations. B. CONDUIT 1.All wiring shall be installed in listed metallic conduit except as permitted below. RGS, with a 20 mil PVC coating will be used when in contact with earth. IMC may be used in indoor locations not in contact with the earth. EMT may be used in indoor locations not in contact with earth, not in concrete slabs or walls and not subject to damage. PVC may be used in or below concrete and direct buried in earth. Flexible steel conduit shall be used for indoor final connections to equipment in lengths not to exceed 72". Liquid-tight flexible steel conduit shall be for outdoor final connections to equipment not to exceed 36". 2.Cover metallic conduit in contact with earth with polyethylene taped spiral wrapped, 1/2 lapped to provide 20 mil. thickness. Tape shall be Scotch no. 50 tape. Conduit and ducts not under buildings and feeder ducts shall be installed per N.E.C. 300-5. make joints with compound to be watertight. 3.Fittings and conduit bodies shall be steel. No diecast fittings. 4.Conduit sizes shall be as required by code and as indicated or specified. 5.All empty conduit systems shall have a nylon pull string to facilitate installation of future wire. 6.Schedule 40 PVC conduit shall be permitted underground with proper fittings, all UL Approved and cemented joints. Penetrations through floor slabs and bends greater than 22° shall be wrapped rigid galvanized steel elbows. 7.Conduits and outlets shall be concealed with the building structure, except that certain motor and lighting feeder conduits may be run exposed in certain areas as indicated on the drawings. Conduit shown to be installed in cabinets, counters, and casework shall be run as directed by the architect. 8.All conduit systems shall have a Code sized copper ground conductor increase conduit size as required. 9.Conduit penetration through roof shall have roof flashing with caulk type counter flashing sleeve. Installation shall be watertight. 10.Conduits shall be routed surface on the structure, parallel and perpendicular to the structure. C. OUTLET, PULL, AND JUNCTION BOXES 1.Each switch, light. receptacle or other outlet shall be provided with a Code gauge, galvanized steel outlet box. Junction and pull boxes shall be Code gauge, galvanized steel. Outlet boxes shall be of the one piece, knockout type, in general 4" square with plaster ring. Plaster rings shall be set to provide not more than 1/8" from wall surface to ring. In no case shall plaster ring project beyond surface of wall. Single gang rings similar to Steel City 52050 shall be used for 4" boxes in unfinished brick number 180 boxes may be used for unfinished masonry flush wall outlets. Center all outlet boxes in block course. 2.Boxes installed in poured cement floors shall be flush type cast iron or steel with watertight gasketed covers. Where boxes are installed in floors with tile or carpet floor covering, covers shall be of the recessed type to accommodate the floor covering. 3.Boxes installed for the alarm, computer, and security system shall be provided with appropriate cover plates. 4.Boxes for telephone, computer, TV, fire alarm, security, and similar systems shall be minimum 4" square and 2-1/8" deep. D. SWITCHBOARDS, DISTRIBUTION BOARDS, MOTOR CONTROL CENTERS 1.See Single Line Diagram General Notes on drawings for more information. E. PANEL BOARDS 1.See drawings for panel board schedules and specifications. F. WIRE 1.Conductor sizes shown on the drawings are based on copper wire. Unless otherwise specified, all wire shall be Type XHHW for feeders or branch circuits larger than 4 AWG, Type THHN/THWN insulation for feeders and branch circuits 4 AWG and smaller. All branch circuit wiring shall be copper. The wire shall be 12 AWG unless otherwise indicated. Circuit shall be labeled in each junction box. 2.Metal Clad Cable "Type MC" cable may only be utilized for interior branch circuitry supplying lighting fixtures, not to exceed 6-ft. in length from junction box to the fixture served. "Daisy Chaining" of light fixtures is not allowed. 3.When use is permitted in the Allowed Specification Deviations, Metal Clad "Type MC" cable may be installed per NEC Article 330. Where multiple cables are routed adjacent to each other (bundled), a minimum separation of one (1) cable diameter (largest) shall be required. 4.The wires shall be marked with color to simplify circuit identification. Unless otherwise required by local ordinances: 208/120 Volts Phase A = Black Phase B = Red Phase C = Blue Neutral = White Ground = Green 480/277 Volts Phase A = Brown Phase B = Orange Phase C = Yellow Neutral = Gray Ground = Green 5.No wire shall be installed in the conduit system until the conduit system is complete. Use Mineralac No. 100 or equivalent as a lubricant to facilitate the installation of the conductors in the conduit system. 6.Splices in exterior pull boxes and manholes shall be weatherproof using "Scotchcast" splice kit or approved equal. Seal ends of conduits and ducts with "Ductseal" or approved equal. 7.Provide solid conductor for 12 AWG and smaller. 8.Provide 10 AWG conductors for 20 ampere, 120V branch circuits longer than 75-feet and 8 AWG conductors for 20 ampere, 120V branch circuits longer than 120-feet. Provide 10 AWG conductors for 20 ampere, 277V branch circuits longer than 200-feet. G. WIRING DEVICES 1.Wall switches shall be Specification Grade AC silent type switches, 20A, 120/277 volt. 2.Receptacles shall be Specification Grade, duplex type, NEMA 5-20R, 20 ampere, 120 volt grounded type. Special application receptacles shall be indicated on plans. Mount with the ground down. 3.Device plates shall be equal to sierra smooth-line plastic wall plates. Color shall be white, unless otherwise noted. 4.All receptacles identified as weatherproof on the drawings shall be weather-resistant, tamper-resistant, GFCI type and equipped with enclosure that is weatherproof (WP) whether or not the attachment plug cap is inserted (while "IN-USE"). An outlet box hood shall be listed and shall be identified as "Extra Duty". 5.Except as otherwise noted, all wiring device plates on the project shall be labeled with panel and circuit number(s) utilizing a Brother P-touch labeling system with 1/2" tape (yellow on black) or equal HellermannTyton or Panduit. Locate label on the concealed side of the wiring device plate. Handwritten labels are unacceptable. H. LIGHTING FIXTURES 1.Provide all lighting fixtures, wired and connected. the drawings indicate the fixtures for each location. Provide lamps for all fixtures. The lamps shall be by the same manufacturer. Verify ceiling construction before ordering recessed units. Provide plaster frames and hangers as required. Ceiling construction, architectural accessories, voltage, and ballasts to meet the existing condition. J. SYSTEM GROUNDING 1.Grounding shall comply with requirements of Article 250. All exposed non-current carrying metallic parts of electrical equipment, metallic raceway systems, metallic cable armor, grounding conductor of nonmetallic sheathed cables, grounding conductor in nonmetallic raceways, and grounded conductors of the wiring system shall be grounded. 2.Grounding conductor (neutral) of the wiring system shall be connected to the system grounding conductor at a single place in each system by removable bonding jumpers, sized according to the applicable provisions of the National Electrical Code. The grounded conductor (neutral) to the grounding conductor connection shall be located in the enclosure for the system's overcurrent protection or where otherwise indicated on the plans or specifications. 3.A ground bus separate from the neutral bus shall be provided in all switchboards and panelboards. Ground bus shall be retorqued (checked) prior to energizing equipment per manufacturer's recommendations. 4.Ground buses and neutral buses in all distribution panels, switchboards, panelboards, and those provided in any equipment shall be isolated except where required to be connected as specified above for the service entrance and in transformer terminal compartments. 5.When indicated on the drawings, equipment grounding conductors shall be extended from the ground bus in the distribution equipment to the receptacle, fixture or device lugs where they are provided. Where lugs are not provided, equipment grounding conductors shall be connected to equipment enclosures. The connections shall be arranged such that removal of the receptacle, equipment ground conductors, or ground jumpers from ground busing shall not affect the ground system. 6.Raceways may not be used as a grounding conductor for power and lighting circuits. All conduit shall have separate Code sized green ground wire installed in the conduit to insure a continuos grounding path. 7.In inaccessible locations, make connections by exothermic weld process. 8.In accessible locations, connections shall be made with bolted through, approved solderless bronze grounding devices. 9.Bond together metal siding not attached to grounded structure bond to ground. K. TELEPHONE SYSTEM 1.Telephone wall outlets shall consist of standard boxes mounted 18" above the floor unless otherwise indicated. Connect outlets to telephone terminal with separate 3/4" conduit unless otherwise shown on drawings. Provide a terminal mounting board for the incoming service cable. L. LIGHTING CONTROL 1.Furnish and install time switches, photocells, contactors and full lighting control systems as required for lighting controls indicated on the drawings. 2.Time switches shall be equal to Paragon, General Electric, Tork, or Intermatic and shall have size and number of poles as required. 3.Photocells shall be equal to Tork or Intermatic with voltage as indicated. N. GUARANTEE 1.Guarantee all material furnished and all workmanship performed for a period of one year from date of final acceptance of work. Any defects developing within this period, traceable to material furnished as a part of this section or workmanship performed hereunder, shall be made good at no expense to the owner. O. SHOP DRAWINGS AND APPROVALS 2.The items specified herein and on drawings are used as a standard of quality. any materials of equal quality and aesthetic value will be given consideration as a substitute for the materials specified. No approval will be given to a specific catalog number, model, or type of equipment, prior to bidding. After bidding, the decision of the Architect and/or Engineer determining equal materials will be final. 3.The contractor shall submit shop drawings on the following items: 3.1.Lighting fixture cuts and performance data. 3.2.Outline drawings and data sheets of each panelboard and switchboard. 3.3.Outline drawings of all switchgear. 4.Submit items at one time in a neat and orderly manner within 15 days of award of contract. Partial submittals will not be acceptable. P. RECORD AND AS-BUILT DRAWINGS 1.The Electrical Contractor shall maintain a set of drawings at the job site for the exclusive purpose of maintaining a record of all work installed and to show any deviations from the work indicated on the drawings. 2.At the completion of the project, one set of reproducible drawings, showing all As-Built conditions, shall be delivered to the Owner for acceptance prior to final payment. R. EQUIPMENT CONNECTIONS 1.Provide flexible connections to all HVAC equipment, water heater, etc any equipment over 20 lb and/or mounted above finished floor. 2.Coordinate electrical requirements for all plumbing and mechanical equipment with final Contractor selection. The Contractor shall size disconnects based upon circuit breaker ratings and provide fusing as required per equipment manufacturer recommendations and UL Listing requirements. T. FIRE SYSTEM 1.Contractor shall engage the services for a state licensed fire alarm manufacturer/installer to prepare all design drawings and calculations required for system approval by the authority having jurisdiction. Submit all plans and provide all permits required for a complete and operable approved life safety system. 2.Fire alarm device wiring shall be minimum #14 AWG copper or per system manufacturer requirements. Provide minimum 3/4" separate raceway system or as required for life safety system wiring configuration. 3.Upon completion of the installation of life safety system wiring and devices, a performance test of the entire life safety shall be performed to the satisfaction of the authority having jurisdiction. U. LOW VOLTAGE SYSTEMS 1.Music, television, video mounting systems are not shown on these drawings and are provided by Contractor through architects schedules/details. Contractor to coordinate all routing and final connections as approved by Starbucks Manager as applicable specifically to this store. V. IDENTIFICATION OR EQUIPMENT LABELING 1.Nameplates shall be provided for switchgear, switchboards, distribution boards, distributions panels, panel boards, motor control centers, transformers, transfer switches, contactors, starters, disconnect switches, enclosed circuit breakers/switches, Inverters, UPS's, PDU's, RDC's, SPD's, lighting control panels, dimming panels, door releasing system panels, fire alarm/central monitoring terminal cabinets/power supplies/control panels, and all low voltage system terminal and control cabinets. 1.1.Nameplate inscriptions shall be identical to the equipment designations indicated in plans and specifications. Nameplates shall be engraved with the device designation/identification on the top line, source identification for the device on the 2nd line per NEC, Art 408.4 and load designation for the device on the bottom line. Where load designation consists of a branch circuit, omit bottom line. Where device designation is not intended on plan/specfications. Contractor shall submit a written clarification request to the Engineer. 1.2.All circuit breakers/fuses in switchgear, switchboards, distribution boards, distribution panels, UPS output circuit breakers, PDU sub-feed circuit breakers and motor control centers shall have individual nameplates located immediately adjacent to the respective device. Nameplate inscription shall identify the downstream equipment or device served by the circuit breaker or fuse. 2.Identification nameplates, unless otherwise noted (UON), shall be laminated/extruded modified acrylic or melamine plastic labels that is 3/32" thick, UV-stabilized, matte finish, suitable for use in 180°F ambient, with beveled edges and engraved white letters 3/8" high, minimum, on 1-1/2" high black background for single line of text. Where two lines of text are required, provide minimum 2" high nameplate. Where three lines of text are required, provide 2.5" high nameplate. Provide white letters on red background for all NEC, Article 517 essential power systems, Article 700 Emergency Systems, Article 701 Legally Required Standby Systems and Article 708 COPS. 3.Identification nameplates for new switchgear, switchboards, distribution boards, distribution panels, panel boards and motor control centers shall be attached with switchgear manufacturer-provided screws via switchgear manufacturer factory pre-drilled holes. A factory option to rivet identification nameplates to the equipment is only acceptable if screw-fastened nameplates are not an available option from the switchgear manufacturer. Field drilling or other mechanical attachment methods that change/void the NEMA or NTRL rating of the enclosure are strictly forbidden. 4.Identification nameplates for transformers, transfer switches, disconnect switches, enclosed circuit breakers/switches, inverters, UPSs, PDUs, RDCs, SPDs, lighting control panels, dimming panels, door-releasing system panels, terminal cabinets and all circuit breakers/fuses in switchgear, switchboards, distribution boards, distribution panels, UPS output circuit breakers, PDUs, PDU sub-feed circuit breakers, and motor control centers shall be attached to the equipment by self-adhesive backing integral to the nameplates. When equipment is located outdoors, provide nameplates without self-adhesive backing and attach to equipment using weather-rated, UV-resistant epoxy. In all cases, clean surfaces before applying identification nameplates parallel to equipment lines. 5.Warning Placards, as required by General Single Line Diagram Notes for multiple power sources, or instruction placards, as required for all kirk-key interlock schemes, all UPS bypass procedures or as required elsewhere in the plans/specifications shall be engraved 1/2" high with white lettering on red background using the same material specified for identification nameplates with a self-adhesive backing. Warning/instruction placards shall be attached to the face of the equipment directly related to the placards. STAMP DATE: 04/13/2024 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 ADJACENT TENANT (NIC) L 20662 L 21772 L 21772 L 20661 L 21776 L 19409 L 21779 L 21774 L 20748 L 21774 L 20748 L 21774 L 21783 L 21772 BACKBAR RETAIL SEATING AREA WORKROOM PARTNER / MANAGER AREA UNISEX PARTNER RESTROOM UNISEX CUSTOMER RESTROOM (N) 2X4 ACT AT 10' - 0" AFF (N) GYP BD CEILING AT 10' - 11" AFF BACKBAR (N) GYP BD CEILING AT 9' - 6" AFF (N) SOFFIT AT 7'-6" AFF (SG) (N) SOFFIT AT 11'-10" AFF (N) HEADER AT 9' - 6" AFF (N) 2X4 ACT ABOVE RO & WH AT 12'-6" AFF (N) GYP BD CEILING AT 9' - 0" AFF (N) GYP BD CEILING AT 9' - 0" AFF (N) GYP BD CEILING AT 9' - 0" AFF (N) GYP BD CEILING AT 10' - 11" AFF L 21774 (3) (32) (6) L 21772 (14) L 21772 (4) (6) (2) (2) (2) (2) (N) HEADER AT 7' - 6" AFF L 22216 L 22216 L 22220 L 22220 L 22216 (7) L 21776 UPLIGHT:C DOWNLIGHT:C UPLIGHT:C DOWNLIGHT:B + (N) ZINTRA ACOUSTICAL BAFFLES AT 11' - 2" AFF L 19411 L 21779 (3) L 19409 L 21779 L 19409 L 21779 (2) L 19409 L 21779 L 19409 L 21779 TYP. 22w/22EB 22w 22w 22w/22EB 22w 22w 22w 22w 22p22p22p 22p/22EB 22p 22p 22u 22u 22u 22v/22EB 22v 24b 24b24b 24b/24EB 24b24b 24b 24b 24b 24b 24b 24b 24b 24b/24EB 24c 24b 24b 24b 24b 24b 24b24b24b24b24b24b24b24b24b24b24b24b24b24b24b24b24b/24EB 24b 24b/24EB 24b 24r 24b24b24b24b24b24b24b24b24b24b24b24b/24EB 24r 24r 24r 24r 24r 24r 22n 22n 22n 24t 24t 24t 24t/24EB24t/2EB 24t 24r 24t 24t 24r 24r 24r 24NL/24EB 22NL/22EB 24b 24c 22u 1 24b 5 6 4 4 7 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 76085-018 <XX-XX-XXXX> TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 Revision Schedule Rev Date By Description E200 LIGHTING PLAN SCALE:1/4" = 1'-0"1 LIGHTING PLAN REFERENCE NOTES NEW LUTRON SWITCHBANK, REFER TO LUTRON ONE-LINE AND LOOP LAYOUT. LIGHT SWITCHES ARE SPECIFIED ON LUTRON ONE-LINE. NEW EMERGENCY/EXIT FIXTURE, GC TO PERFORM TEST TO ENSURE EMERGENCY BATTERY UNIT WILL PROVIDE BACKUP POWER FOR MINIMUM 90 MINUTES. ROUTE CIRCUIT VIA LUTRON VIVE SYSTEM TIME CLOCK. DASHED LINE INDICATES LED LIGHT TAPE HOUSED WITHIN SOFFIT LIGHT COVE. DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE UPPER CBE CABINETRY. DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE FRONTLINE COUNTERTOP BELOW. DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE PARTNER REST UPPER CABINETRY. 1 2 3 4 5 6 7 A.PROVIDE A DISCONNECTING MEANS FOR EACH MULTI-WIRE LIGHTING BRANCH CIRCUIT IN ACCORDANCE WITH NEC 410.130(G)(1)THRU(3). DISCONNECTING MEANS SHALL BE LOCATED AT POINT WHERE CIRCUIT ORIGINATES AND SHALL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS. B.REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION AND ELEVATION OF ALL LIGHTING FIXTURES. C.THE FIXTURE SCHEDULE INDICATES GENERAL DESCRIPTION OF LIGHTING FIXTURES AND MANUFACTURERS CATALOG NUMBERS. IT SHALL BE THE CONTRACTORS RESPOSIBILITY TO VERIFY EXACT CEILING CONSTRUCTION WITH ARCHITECTURAL REFLECTED CEILING PLAN AND PROVIDE LIGHTING FIXTURES WITH ALL NECESSARY TRIMS, AND MOUNTING HARDWARE. D.COORDINATE EXACT LIGHTING FIXTURE LOCATIONS WITH ELECTRICAL, MECHANICAL, PLUMBING EQUIPMENT, INCLUDING CONDUIT, PIPING, DUCTING ,ETC PRIOR TO ROUGH-IN. E.ALL RECESSED FIXTURES SHALL BE PROVIDED WITH ALL REQUIRED STRUCTURAL SUPPORTS AS REQUIRED BY THE CURRENTLY ADOPTED ISSUE OF THE BUILDING CODE, AS WELL AS ANY LOCAL CODES. F.ALL DIMMING BRANCH CIRCUITS SHALL BE PROVIDED WITH A DEDICATED NEUTRAL CONDUCTOR FOR EACH ZONE/CHANNEL. G.ALL EMERGENCY BATTERY PACK FIXTURES SHALL BE PROVIDED WITH A CONSTANT HOT CONNECTION TO THE CHARGING LEAD OF THE LOCAL AREA CIRCUIT. H.REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXIT SIGN CHEVRONS AND NUMBER OF FACES PER EXIT SIGN. ANY DISCREPANCIES BETWEEN EXIT SIGNS SHOWN ON THE ELECTRICAL AND ARCHITECTURAL PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO ORDERING EXIT SIGNS. A JUNCTION BOX MUST BE PROVIDED WITH ALL EXIT LIGHTS CONNECTED TO MORE THAN ONE SET OF CONDUCTORS UNLESS THE EXIT LIGHT FIXTURE IS FURNISHED WITH AN APPROVED OUTLET BOX FOR THROUGH WIRING. I.ALL LOW VOLTAGE LIGHTING SYSTEMS SHALL COMPLY WITH NEC 411 AND SHALL BE LISTED PER 411.3 OR LOCAL CODES HAVING JURISDICTION. J.ALL ELECTRICAL EQUIPMENT LOCATED OUTSIDE SHALL BE WEATHERPROOF. K.ALL LOW VOLTAGE WIRING NOT RUN IN CONDUIT SHALL BE PLENUM RATED. L.MOUNT ALL SWITCHES, CONTROLS, RECEPTACLES BETWEEN 15"-48" AFF. H.ADDITIONAL RELAY ZONES MAY BE REQUIRED FOR THE ADDITION OF PRIMARY DAYLIT, SECONDARY DAYLIT, AND PRIMARY SKYLIT UTILIZING THE SAME CONTROL CHANNEL. (I.E. EVEN THOUGH A SINGLE LETTER "a" IS INDICATED AT THE PRIMARY SENSOR), ADDITIONAL RELAYS WOULD BE REQUIRED FOR THE: "a+"PRIMARY SIDELIT DAYLIT ZONE "a++"SECONDARY SIDELIT DAYLIT ZONE, AND "a*"SKYLIT DAYLIT ZONE WHERE MORE THAN ONE CIRCUIT /THREE SWITCH LEGS/THREE RELAY ZONES ARE REQUIRED PROVIDE ADDITIONAL FULL FEATURE CONTROL UNITS AS REQUIRED. I.LUMINAIRES INDICATED AS EMERGENCY SHALL BE IDENTIFIED / PROVIDED AS FOLLOWS: -FIXTURE CONNECTED TO CIRCUIT "3", CONTROL SWITCH "a" - WITH THE BATTERY CHARGING LEAD CONNECTED TO A CONSTANT HOT CIRCUIT "3". -FIXTURE CONNECTED TO A CONSTANT HOT CIRCUIT "#3". BATTERY CHARGING LEAD CONNECTED TO A CONSTANT HOT CIRCUIT "3". -ROUTED THROUGH A U.L. LISTED TRANSFER RELAY (LC & D # GR - 2001E/S) FOR SWITCHED CONTROL OR A U.L. LISTED TRANSFER SWITCH (BODINE #GTD SERIES DEVICE) FOR DIMMING CONTROLS . CONNECTED TO A CONSTANT HOT EMERGENCY CIRCUIT "3". -FIXTURE CONNECTED TO A CONSTANT HOT EMERGENCY CIRCUIT "#3". 1.INTEGRAL BATTERY PACK (EB): 3a/3EB 3NL/3EB 3a/3EM 3NL/3EM 2.REMOTE BACK-UP SOURCE (EM) LIGHTING PLAN GENERAL NOTES (E) STAMP DATE: 04/13/2024 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 76085-018 <XX-XX-XXXX> TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 Revision Schedule Rev Date By Description E210 LUTRON ONE-LINE DIAGRAM FOR REFERENCE ONLY STAMP DATE: 04/13/2024 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 76085-018 <XX-XX-XXXX> TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 Revision Schedule Rev Date By Description E220 LUTRON LOOP LAYOUT FOR REFERENCE ONLY STAMP DATE: 04/13/2024 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 ADJACENT TENANT (NIC) BACKBAR RETAIL SEATING AREA WORKROOM PARTNER / MANAGER AREA UNISEX PARTNER RESTROOM UNISEX CUSTOMER RESTROOM Y 19581 1 E310 SA-20 T A- 1 6 T A- 1 8 RA-13 13620A-19 UA-15,17 23 1 8 2 A- 1 2 , 1 4 23 4 2 3 A- 8 +72" A1 B- 3 9 A1 B-43 23454B-29 10267B-31 +84" +84" +84" A B (E) (E) +84"+84" 2 1 E330 2 E330 QA-47 A-47 1 FOR AIR CURTAIN B-38 A-50 B-25 B-25 WA-25,27,29 23355A-49 100AS/3P +76" 3 +54" A-51 A-51 FOR R.O. SYSTEM +47" A-23 A EXISTING ITEMS TO PRESERVE AND RELOCATE A BLENDERS (2) B ESPRESSO MACHINES (2) C SAFE Q WATER FILLING STATION K WARMING OVEN (2) T 2-DR REACH IN FRIDGE (2) S 2-DR REACH IN FREEZER D WARMING U/C FRIDGE (2) P MANAGER'S STATION EQUIPMENT R 1-DR REACH IN FREEZER E 1-DR U/C FRIDGE (5) M DRIVE-THRU POS EQUIPMENT L POS EQUIPMENT, PRINTER, & PHONE H NITRO TAP / NITRO GENERATOR G CUP LABELER (4) F GRINDER I NOT USED J CUP CADDY (2) N PASTRY CART O AV DIGITAL PRODUCTION MANAGER V THAW RACK U SANITIZER W R.O. SYSTEM & WATER HEATER X TRASH BIN Y METRO RACKS (10) Z ICE BIN A1 HAND DRYER (2) B1 DATA RACK C1 LOCKERS (2) 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 76085-018 <XX-XX-XXXX> TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E SA N T A A N A , C A , 92 7 0 5 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1S T P E R M I T S U B M I T T A L S E T - 0 7 / 0 2 / 2 0 2 4 Revision Schedule Rev Date By Description E300 POWER PLAN SCALE:1/4" = 1'-0"1 POWER PLAN A.ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET 24" MINIMUM. B.ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. C.HEIGHT OF ALL RECEPTACLES AT COUNTER SHELVES, ETC., SHALL BE VERIFIED WITH OWNER PRIOR TO ROUGH-IN. D.ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C. RUN CODE SIZE INSULATED EQUIPMENT GROUND CONDUCTOR. E.EACH AND EVERY 125VAC THROUGH 250VAC RECEPTACLE SUPPLIED BY A SINGLE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND, 50 AMPERES OR LESS, AND ALL THREE-PHASE RECEPTACLES RATED 150 VOLTS OR LESS TO GROUND, 100 AMPERES OR LESS INSTALLED IN KITCHEN, FOOD PREPARATION, BAR AREAS AND RESTROOMS SHALL HAVE A GROUND FAULT CIRCUIT-INTERRUPTER PROTECTED RECEPTACLE OR RECEPTACLE(S) PROTECTED BY GFCI CIRCUIT BREAKER. ANY RECEPTACLE INSTALLED WITHIN 6 FEET OF A SINK MUST BE G.F.C.I. TYPE. F.FOR ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES TO BE LOCATED: A. NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, AND B. NO LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, TO THE LEVEL OF THE FINISHED FLOOR OR WORKING PLATFORM. G. CIRCUIT NUMBERS ARE BASED ON CURRENT PANEL SCHEDULES. WHERE CIRCUIT IS TO BE REPLACED OR RELOCATED, CONTRACTOR IS TO VERIFY CORRECT NUMBERING AND UPDATE THE PANEL SCHEDULE. H. ELECTRIC OUTLETS, SWITCHES, THERMOSTATS, FIRE ALARMS AND SIMILAR DEVICES SHALL BE LOCATED A MINIMUM OF 15" ABOVE THE FINISHED FLOOR, MEASURED TO THE BOTTOM OF THE BOX, AND A MAXIMUM OF 48" ABOVE THE FINISHED FLOOR, MEASURED TO THE TOP OF THE BOX. J. ALL PANEL CIRCUIT NUMBERS ARE FOR REFERENCE ONLY, AND ARE BASED ON EXISTING PANEL SCHEDULES FOUND AT SITE. CONTRACTOR TO PROVIDE AN UPDATED PANEL SCHEDULE TO OWNER UPON COMPLETION. K.ELECTRIC WATER HEATERS MUST BE PROVIDED WITH A DISCONNECT. THE CIRCUIT BREAKER MAY SERVE AS THIS DISCONNECT WHEN IT IS WITHIN SIGHT OF THE WATER HEATER OR WHEN PROVIDED WITH A LOCK-ON / LOCK OFF FEATURE. POWER PLAN GENERAL NOTES REFERENCE NOTES PROVIDE 2#8 & 1#10 EGC IN 3/4"C INDICATES ADA "PUSH TO OPEN" PUSH PAD FOR ADA COMPLIANT AUTOMATIC DOOR OPENER. REFER TO MANUFACTURER'S WIRING DIAGRAM FOR TERMINAL CONNECTION. REFER TO ARCHITECTURAL PLANS FOR MANUFACTURER AND MODEL NO. PROVIDE 3#4 & 1#8 EGC IN 1-1/4"C TAMPER-RESISTANT RECEPTACLE OUTLET WITH USB CHARGING PORT PROVIDED BY BANQUETTE SEATING SUPPLIER. COLOR TO MATCH BANQUETTE SEATING. ELECTRICAL CONTRACTOR TO PROVIDE CONNECTION TO JUNCTION BOX. JUNCTION BOX FOR BANQUETTE SEATING SUPPLIED RECEPTACLE OUTLETS. 1 2 3 4 5 5 4 (TYP) A 07/02/24 D/T AIR CURTAIN/ HAND SINK STAMP DATE: 07/02/2024 Email: info@peccusa.com Phone: 909.610.5364 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 2301 N Tustin Ave #A8/22/2024 (2) F B- 2 0 23 3 8 1 A- 3 1 , 3 3 K B- 1 , 3 K B- 5 , 7 D B- 1 8 D B- 1 8 G B- 9 23 4 4 3 A- 3 5 , 3 7 , 3 9 10 2 6 7 B- 2 1 23 4 4 4 A- 4 2 , 4 4 E B- 1 2 E B- 6 B B- 2 , 4 B B- 1 4 , 1 6 222 C A- 4 1 L B- 1 9 L B- 1 7 16238B-13,15 B-11 10 2 6 7 B- 1 0 O B- 1 0 22970A-46 1 E320 1 E320 2 2 4 1 222 2 33 4 4 5 A-36 2 22 6 4 2 22 6 4 2 G B- 9 224 6 A A EXISTING ITEMS TO PRESERVE AND RELOCATE A BLENDERS (2) B ESPRESSO MACHINES (2) C SAFE Q WATER FILLING STATION K WARMING OVEN (2) T 2-DR REACH IN FRIDGE (2) S 2-DR REACH IN FREEZER D WARMING U/C FRIDGE (2) P MANAGER'S STATION EQUIPMENT R 1-DR REACH IN FREEZER E 1-DR U/C FRIDGE (5) M DRIVE-THRU POS EQUIPMENT L POS EQUIPMENT, PRINTER, & PHONE H NITRO TAP / NITRO GENERATOR G CUP LABELER (4) F GRINDER V THAW RACK U SANITIZER W R.O. SYSTEM & WATER HEATER X TRASH BIN I NOT USED J CUP CADDY (2) N PASTRY CART O AV DIGITAL PRODUCTION MANAGER Y METRO RACKS (10) Z ICE BIN A1 HAND DRYER B1 DATA RACK C1 LOCKERS (2) 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 76085-018 <XX-XX-XXXX> TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E SA N T A A N A , C A , 92 7 0 5 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1S T P E R M I T S U B M I T T A L S E T - 0 7 / 0 2 / 2 0 2 4 Revision Schedule Rev Date By Description E310 ENLARGED ENGINE PLAN SCALE:1/2" = 1'-0"1 ENLARGED FF&E POWER PLAN A.ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET 24" MINIMUM. B.ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. C.HEIGHT OF ALL RECEPTACLES AT COUNTER SHELVES, ETC., SHALL BE VERIFIED WITH OWNER PRIOR TO ROUGH-IN. D.ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C. RUN CODE SIZE INSULATED EQUIPMENT GROUND CONDUCTOR. E.EACH AND EVERY 125VAC THROUGH 250VAC RECEPTACLE SUPPLIED BY A SINGLE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND, 50 AMPERES OR LESS, AND ALL THREE-PHASE RECEPTACLES RATED 150 VOLTS OR LESS TO GROUND, 100 AMPERES OR LESS INSTALLED IN KITCHEN, FOOD PREPARATION, BAR AREAS AND RESTROOMS SHALL HAVE A GROUND FAULT CIRCUIT-INTERRUPTER PROTECTED RECEPTACLE OR RECEPTACLE(S) PROTECTED BY GFCI CIRCUIT BREAKER. ANY RECEPTACLE INSTALLED WITHIN 6 FEET OF A SINK MUST BE G.F.C.I. TYPE. F.FOR ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES TO BE LOCATED: A. NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, AND B. NO LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, TO THE LEVEL OF THE FINISHED FLOOR OR WORKING PLATFORM. G. CIRCUIT NUMBERS ARE BASED ON CURRENT PANEL SCHEDULES. WHERE CIRCUIT IS TO BE REPLACED OR RELOCATED, CONTRACTOR IS TO VERIFY CORRECT NUMBERING AND UPDATE THE PANEL SCHEDULE. H. ELECTRIC OUTLETS, SWITCHES, THERMOSTATS, FIRE ALARMS AND SIMILAR DEVICES SHALL BE LOCATED A MINIMUM OF 15" ABOVE THE FINISHED FLOOR, MEASURED TO THE BOTTOM OF THE BOX, AND A MAXIMUM OF 48" ABOVE THE FINISHED FLOOR, MEASURED TO THE TOP OF THE BOX. J. ALL PANEL CIRCUIT NUMBERS ARE FOR REFERENCE ONLY, AND ARE BASED ON EXISTING PANEL SCHEDULES FOUND AT SITE. CONTRACTOR TO PROVIDE AN UPDATED PANEL SCHEDULE TO OWNER UPON COMPLETION. K.ELECTRIC WATER HEATERS MUST BE PROVIDED WITH A DISCONNECT. THE CIRCUIT BREAKER MAY SERVE AS THIS DISCONNECT WHEN IT IS WITHIN SIGHT OF THE WATER HEATER OR WHEN PROVIDED WITH A LOCK-ON / LOCK OFF FEATURE. REFERENCE NOTES INDICATES POWER AND DATA OUTLETS FOR DIGITAL MENU BOARDS. REFER TO DETAIL 1/I504 FOR ADDITIONAL INFORMATION. INDICATES POWER AND DATA OUTLETS FOR ORDER STATUS BOARD. REFER TO DETAIL 3/I504 FOR ADDITIONAL INFORMATION. PROVIDE 2#8 & 1#10 EGC IN 3/4"C PROVIDE 2#10 & 1#10 EGC IN 1/2" C PROVIDE 2#6 & 1#10 EGC IN 3/4"" C INDICATES ELECTRICAL CONNECTION FOR AIR CURTAIN. 1 2 3 4 5 6 POWER PLAN GENERAL NOTES A-48 A 07/02/24 D/T AIR CURTAIN/ HAND SINK STAMP DATE: 07/02/2024 Email: info@peccusa.com Phone: 909.610.5364 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 2301 N Tustin Ave #A8/22/2024 CEILING ELEVATION - ELECTRICAL DIAGRAM POWER AND DATA RECEPTACLES AT 28" (710MM) TO TOP OF RECEPTACLE A.F.F. SOFFIT POWER AND DATA RECEPTACLES AT 83" (2030MM) TO TOP OF RECEPTACLE A.F.F. JBOX FOR UNDERCABINET LIGHTING ELEVATION - ELECTRICAL DIAGRAM RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR RECEPTACLE FOR BLENDER(S)* RECEPTACLE FOR FUTURE USE 2-DATA PORT FOR LABEL PRINTER 2-DATA PORT FOR FUTURE USE *BLENDER QUANTITY BASED ON EQUIPMENT SCHEDULE POWER AND DATA RECEPTACLES AT 28" (710MM) TO TOP OF RECEPTACLE A.F.F. UNDERCOUNTER NITRO REFRIGERATOR RECEPTACLE FOR UNDERCOUNTER NITRO REFRIGERATOR RECEPTACLE FOR NITROGEN GENERATOR RECEPTACLE FOR DPM TABLET 2-DATA PORT FOR DPM TABLET AND FUTURE USE POWER AND DATA RECEPTACLES AT 28" (710MM) TO TOP OF RECEPTACLE A.F.F. POWER RECEPTACLE FOR RINSE SINK AT 28" (710MM) TO TOP OF RECEPTACLE A.F.F. UNDERCOUNTER REFRIGERATOR UNDERCOUNTERNITROGEN GENERATOR PLAN - UPPER ELECTRICAL DIAGRAM RECEPTACLE FOR MILK DISPENSER RECEPTACLE FOR ICE DISPENSER RECEPTACLE FOR LABEL PRINTER AND FUTURE USE 2-DATA PORT FOR LABEL PRINTER POWER AND DATA RECEPTACLES AT 83" (2100MM) TO TOP OF RECEPTACLE A.F.F. RECEPTACLE FOR MILK DISPENSER POWER AND DATA RECEPTACLES AT 83" (2100MM) TO TOP OF RECEPTACLE A.F.F. PLAN - ELECTRICAL DIAGRAM 2 2 2 2 2 20 0 1 0 B- 3 5 H B- 3 3 A B- 3 4 E B- 4 0 A B- 3 6 E B- 4 0 23 4 1 9 A- 4 3 23 4 1 9 A- 4 3 17 5 6 4 B- 3 7 23 4 2 1 A- 4 3 G B- 9 2 DEDICATED QUAD RECEPTACLE FOR DT DIGITAL PRODUCTION MONITOR, UPS UNIT (FOR TENDERING REGISTER EXPEDITOR, POS AND PED) AND FUTURE USE DEDICATED QUAD RECEPTACLE FOR FUTURE USE 2-DATA J-BOX 4-DATA J-BOX POWER AND DATA RECEPTACLES DEDICATED QUAD RECEPTACLE FOR DRIVE THRU TIMER MONITOR AND CONTROL UNIT. (2) DEDICATED DUPLEX RECEPTACLE FOR WIRELESS BASE AND SIGNAL PROCESSOR WITH CIRCUIT ISOLATED GROUND 2-DATA J-BOX SINGLE DATA J-BOX POWER AND DATA RECEPTACLES QUAD RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR AND FUTURE USE POWER RECEPTACLE UNDERCOUNTER REFRIGERATOR DUPLEX CONVENIENCE POWER RECEPTACLE EDGE OF COUNTERTOP NOTE :EQUIPMENT SHOWN AS DASHED LINES IS TO BE FURNISHED AND INSTALLED BY OWNER UNLESS NOTED OTHERWISE DRIVE THRU DIGITAL PRODUCTION MONITOR ELEVATION VIEW DRIVE THRU TENDERING REGISTER TRIPLE MONITOR MOUNT (GC INSTALLED) SEE PLAN VIEW FOR MOUNTING LOCATION POWER RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. DEDICATED QUAD RECEPTACLE FOR DT DIGITAL PRODUCTION MONITOR, UPS UNIT (FOR TENDERING REGISTER, EXPEDITOR POS AND PED) AND FUTURE USE DEDICATED QUAD RECEPTACLE FOR FUTURE USE 2-DATA PORT FOR TENDERING REGISTER AND EXPEDITOR POS 4-DATA PORT FOR DT VIDEO, PED AND/OR CONNECT DEVICES POS BANK (TYP) CASH DRAWERS ELEVATION VIEW DRIVE THRU VIDEO CONDUIT FROM DT ORDER POINT TO DT VIDEO DATA BOX AT 28" (711MM) A.F.F. DRIVE THRU EXPEDITOR POS RECEIPT PRINTER DT AUDIO CONDUIT FROM DRIVE THRU ORDER POINT AND DETECTOR LOOP CONDUIT FROM DT WINDOW TO DT TIMER CONTROL DATA JUNCTION BOXES AT 8'-2" (2490MM) POWER RECEPTACLE AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. QUAD RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR AND FUTURE USE SINGLE DOOR REFRIGERATOR DUPLEX CONVENIENCE OUTLET AT 45" (1143MM) TO TOP OF RECEPTACLE A.F.F. DIMENSIONS INDICATE CENTER MOUNTING POINT FOR MONITOR BASE * DRIVE THRU WIRELESS HEADSET BASE STATION DRIVE THRU TIMER MONITOR DRIVE THRU TIMER CONTROL UNIT POWER AND DATA RECEPTACLES AT 8'-2" (2490MM) TO TOP OF RECEPTACLES A.F.F. DEDICATED QUAD RECEPTACLE FOR DRIVE THRU TIMER MONITOR AND CONTROL UNIT (2) DEDICATED DUPLEX RECEPTACLE FOR WIRELESS BASE AND SIGNAL PROCESSOR WITH CIRCUIT ISOLATED GROUND 2-DATA PORT FOR DT TIMER AND CONTROL UNIT SINGLE DATA PORT FOR DT AUDIO (MIC & SPEAKER) DRIVE THRU TIMER SIGNAL PROCESSOR (TSP) 36" W X 51" H (915MM W X 1295MM H) MIN. FIRE RATED PLYWOOD BACKER BOARD. FASTEN TO STRUCTURE. WALL FINISH TO CONCEAL. FUTURE HHOP CABLING TO HEADSET BASE STATION FROM J-BOX AT CLG/WALL FOR EXTERNAL EXTENDED COVERAGE ANTENNA (FOIO) 2 4 2 M B- 4 4 E B- 2 1 B- 4 5 B- 4 6 B-41 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 76085-018 <XX-XX-XXXX> TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 Revision Schedule Rev Date By Description E320 ELECLTRICAL DETAILS SCALE:3/4" = 1'-0"1 SIREN SYSTEM SCALE:3/4" = 1'-0"2 DRIVE THRU EQUIPMENT STAMP DATE: 04/13/2024 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 NOTE :EQUIPMENT SHOWN AS DASHED LINES IS TO BE FURNISHED AND INSTALLED BY OWNER UNLESS NOTED OTHERWISE. PLAN VIEW ELEVATION VIEW 1 SECURE KEY BOX CEILING HEIGHT SHOWN AT 96" (2440MM). REFER TO REFLECTED CEILING PLAN(S) FOR ACTUAL HEIGHT. LOW VOLTAGE CABLE BUNDLE 1 MUSIC SYSTEM PLAY NETWORK SPEAKERS 2" (50MM) Ø SLEEVE FOR LOW VOLTAGE CABLE BUNDLE MOUNTED TO (2) UNISTRUTS CEILING TRIM RING PRINTER ROLLING CART IPOD TOUCH CHARGING CRADLE CASH SCALE HOME PHONE CONNECT (HPC) 60" W X 70" H (1525MM W X 1780MM H) MIN. 3/4" FIRE RATED PLYWOOD BACKER BOARD. FASTEN TO STRUCTURE TO HOLD MIN. 350 PSF. PAINTABLE SURFACE ON ROOM SIDE & FINISH AS SCHEDULED. POWER, TELEPHONE & DATA RECEPTACLES AT 12" (305MM) A.F.F. TO CENTER OF GROUPING. SEE FLAN VIEW NOTE "A" ABOVE FOR DESCRIPTION. POWER & DATA RECEPTACLES AT 60" (1525MM) A.F.F. TO CENTER OF GROUPING. SEE NOTE 'B ' ABOVE FOR DESCRIPTION. DESK OFFICE PC LAPTOP SLEEVE FOR LOW VOLTAGE CABLE BUNDLE MOUNTED TO (2) UNISTRUTS ROLLING CART SHELVING ABOVE POWER & DATA RECEPTACLES (IN WALL, AT MUSIC SYSTEM SHELF) (1) DUPLEX RECEPTACLE FOR: MUSIC SYSTEM AMPLIFIER AND FUTURE USE (1) 2-DATA PORT FOR: CURIO POWER, TELEPHONE & DATA RECEPTACLES (IN WALL, BELOW DESK) (1) QUAD RECEPTACLE FOR: PC, PRINTER, PHONE AND HPC (1) QUAD RECEPTACLE FOR: LAPTOP, CASH SCALE AND FUTURE USE (1) QUAD RECEPTACLE (1) PHONE MAIN (1) 2-DATA PORT FOR: PC AND PRINTER DESK A B WALL MOUNTED SHELVING UNIT ATTACHED TO BACKER BOARD CORDLESS 1 LINE PHONE MUSIC SYSTEM PLAYER AND AMPLIFIER (FURNISHED BY OWNER, INSTALLED WITH SPEAKER SYSTEM BY GC) ON 14" DEEP (355MM) SHELF ONLY (MIN.) 56" W X 42" H (1420MM W X 1065MM H) MIN. 3/4" FIRE RATED PLYWOOD BACKER BOARD. FASTEN TO STRUCTURE TO HOLD MIN. 350 PSF. PAINTABLE SURFACE ON ROOM SIDE AND FINISH AS SCHEDULED. MINI GROUND BAR FOR EQUIPMENT RACK. GC TO COORDINATE RACK GROUNDING TO BAR WITH #6 GROUND WIRE AND PER JURISDICTIONAL REQUIREMENTS POWER & DATA RECEPTACLES AT 87" (2210MM) A.F.F. TO CENTER OF GROUPING. SEE PLAN VIEW NOTE "A" ABOVE FOR DESCRIPTION. EQUIPMENT RACK WALL MOUNTED TO STRUCTURE BY STARBUCKS VENDOR (GC TO COORDINATE INSTALLATION). GROUND RACK PER MFR'S ASSEMBLY INSTRUCTIONS. SEE EQUIPMENT RACK SCHEDULE BELOW FOR EQUIPMENT INCLUDED WITHIN. PLAN VIEW MOUNT GROUND BAR AT 116" (2945MM) A.F.F. ELEVATION VIEW (2) 2" (50 MM) Ø SLEEVES FOR LOW VOLTAGE CABLE BUNDLES MOUNTED TO (2) UNISTRUTS CEILING TRIM RING (TYP.) ENLARGED VIEW LAY-IN CEILING UPS IPS EQUIPMENT ROUTER EQUIPMENT RACK SCHEDULE NETWORK SWITCH PATCH PANEL SECURITY RECORDER (NVR) SECURITY KEYBOARD PRODUCTION CONTROLLER DEVICES NOTE :EQUIPMENT SHOWN AS DASHED LINES IS TO BE FURNISHED AND INSTALLED BY OWNER UNLESS NOTED OTHERWISE. MOUNT EQUIPMENT RACK AT 84" (2133MM) A.F.F. 76" (1930MM) CLEAR AREA BELOW FOR TRASH CONTAINERS, STORAGE OR DELIVERY DROP OFF WIRELESS MODEM AT 92" (2335MM) A.F.F. STARBUCKS VENDOR TO DETERMINE OPTIMAL DEVICE LOCATION DEMARC, IF REQUIRED POWER AND DATA RECEPTACLES AT 104" (2642MM) A.F.F. TO CENTER OF GROUPING. SEE NOTE 'B ' ABOVE FOR DESCRIPTION SECURITY MONITOR MOUNTED ON MONITOR ARM (ATTACHED TO BACKER BOARD). BACK OF HOUSE CEILING HEIGHT PER PLAN 21 6" 6" 4" 100MM LOW VOLTAGE CABLE BUNDLES SECURITY PANEL FUTURE USE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 SECURITY 2 POS HIGH SPEED INTERNET DEMARC EXTENSION POS LAN DT TIMER SECURITY CONTROL ALARM PANEL EMS DATA CONCENTRATOR. ALLOW 2" (50MM) IN. CLEAR ABOVE MAINTAIN 24" (610MM) MIN. CLEARANCE FOR WHEN EQUIPMENT RACK IS IN OPEN ACCESS POSITION (2) SLEEVES FOR LOW VOLTAGE CABLE BUNDLES MOUNTED TO (2) UNISTRUTS EQUIPMENT RACK POWER & DATA RECEPTACLES (IN WALL, ABOVE SHELVES) (1) QUAD RECEPTACLE FOR: EMS DATA CONCENTRATOR (1) DUPLEX RECEPTACLE FOR: SECURITY CONTROL ALARM PANEL (1) 2-DATA PORT FOR: EMS DATA CONCENTRATOR B A POWER RECEPTACLES (IN WALL, BEHIND OF EQUIPMENT RACK) (1) INDIVIDUAL BRANCH CIRCUIT RECEPTACLE FOR: UPS (1) DUPLEX RECEPTACLE FOR: PDU STRIP AND FUTURE USE IOT GATEWAY 2 2 2 B-26 B-24 B-30B-22 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 76085-018 <XX-XX-XXXX> TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 Revision Schedule Rev Date By Description E330 ELECTRICAL DETAILS SCALE:3/4" = 1'-0"1 MANAGER'S DESK SCALE:3/4" = 1'-0"2 EQUIPMENT RACK STAMP DATE: 04/13/2024 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 76085-018 <XX-XX-XXXX> TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 Revision Schedule Rev Date By Description E500 SINGLE LINE DIAGRAM AND PANEL SCHEDULES SCALE:NONE1PANEL SCHEDULES REFERENCE NOTES EXISTING PANEL WITH REVISED LOADS. REFER TO PANEL SCHEDULE THIS SHEET. ALL NEW CIRCUIT BREAKERS INSTALLED WITHIN PANELBOARD SHALL MATCH THE HIGHEST EXISTING AIC RATED BREAKERS WITHIN PANELBOARD. INSPECTOR TO VERIFY AT SITE. THE CONTRACTOR SHALL VERIFY THE METER/MAIN OVERCURRENT PROTECTION DEVICE'S MANUFACTURER AND PART NUMBER. CIRCUIT BREAKERS IN ALL DOWNSTREAM PANELS SHALL BE FROM THE SAME MANUFACTURER OF METER/MAIN OVERCURRENT PROTECTION DEVICE. CIRCUIT BREAKER AIC RATING SHALL MATCH OR EXCEED SERVICE AVAILABLE FAULT CURRENT. OTHERWISE, PROVIDE MAIN BREAKER AS SHOWN ON PANEL SCHEDULE PER CIRCUIT BREAKER MANUFACTURER'S SERIES-RATING CHART. THE CONTRACTOR SHALL FIELD VERIFY SERVICE EQUIPMENT'S AVAILABLE FAULT CURRENT BEFORE ISSUING ANY BID. NOTIFY ELECTRICAL ENGINEER IMMEDIATELY IF MAJOR DISCREPANCIES OCCUR THE EQUIPMENT SHALL BE LEGIBLY MARKED IN THE FIELD TO INDICATE A SERIES COMBINATION RATING WHICH SHALL BE READILY VISIBLE. CONTRACTOR TO AFFIX SERIES COMBINATION RATING LABEL SIMILAR TO AS SHOWN ON DETAIL 3/E500. 1 2 3 4 SCALE:NONE1SINGLE LINE DIAGRAM SCALE:NONE3MANUFACTURER'S SERIES RATING CHART SERIES COMBINATION SYSTEM RATED 65,000 AMPERES. IDENTIFIED REPLACEMENT COMPONENTS REQUIRED. CAUTION TO EXISTING UTILITY TRANSFORMER (E) SERVICE ENTRANCE EQUIPMENT 1200A, 120/208V, 3ɸ-4W, 65kAIC U.G.P.S. G N (E) 600A 3P 1200A BUS (E) 1200A 3P 3 2 (E) MLO A 600A M (E) MLO B 600A (E ) (E) STAMP DATE: 04/13/2024 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 76085-018 <XX-XX-XXXX> TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 Revision Schedule Rev Date By Description E600 INTERIOR LIGHTING COMPLIANCE CERT STAMP DATE: 04/13/2024 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 76085-018 <XX-XX-XXXX> TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 Revision Schedule Rev Date By Description E610 INTERIOR LIGHTING COMPLIANCE CERT STAMP DATE: 04/13/2024 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 76085-018 <XX-XX-XXXX> TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 Revision Schedule Rev Date By Description E620 INTERIOR LIGHTING COMPLIANCE CERT STAMP DATE: 04/13/2024 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 ABBREVIATIONS ABOVE FINISHED FLOOR PLUMBING SYMBOL LEGEND AFF AHJ AUTHORITIES HAVING JURISDICTION APPROX APPROXIMATE BLDG BUILDING CLG CEILING CONST CONSTRUCTION CW DOMESTIC COLD WATER CXA COMMISSIONING AGENT DEG DEGREES DN DTL EC DOWN DETAIL DWG(S) DRAWING(S) EA EACH ELECTRICAL CONTRACTOR ELEC ELECTRICAL EMER EMERGENCY EXIST EXISTING EXT EXTERIOR FD FS F&I FLOOR DRAIN FLOOR SINK FURNISH & INSTALL FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FOIO FURNISHED BY OWNER, INSTALLED BY OWNER FLR FT FLOOR FOOT/FEET FCO FLOOR CLEANOUT GC HR HOUR HVAC HEATING, VENTILATION, AND AIR CONDITIONING HW HOT WATER HS HANDSINK HWS HOT WATER SUPPLY HWR HOT WATER RETURN LL LV LANDLORD LOW VOLTAGE MAX MAXIMUM MC MECHANICAL CONTRACTOR MDP MAIN DISTRIBUTION PANEL MECH MECHANICAL MEP MECHANICAL, ELECTRICAL, AND PLUMBING MFG MANUFACTURER MIN MINIMUM MS MOP SINK NL NTS PC PS NIGHTLIGHT NOT TO SCALE PLUMBING CONTRACTOR PREP SINK POC POINT OF CONNECTION REF REFERENCE REQ’D REQUIRED REV REVISION SHT SF TEL SHEET SQUARE FEET SPECS SPECIFICATION(S) SST STAINLESS STEEL TELEPHONE TEMP TEMPORARY TMV TYPICAL UC TEMPERATURE MIXING VALVE TW TEMPERED HOT WATER TYP UNDER COUNTER UNO UNLESS NOTED OTHERWISE V VENT W SANITARY WASTE WCO WALL CLEANOUT WH WATER HEATER WP WEATHER PROOF APPLICABLE CODES CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE STATE CODES WHETHER INDICATED HEREIN OR NOT. 2022 CALIFORNIA BUILDING STANDARDS CODE: • PART 1 - CALIFORNIA ADMINISTRATIVE CODE (CAC) • PART 2 - CALIFORNIA BUILDING CODE (CBC) • PART 3 - CALIFORNIA ELECTRICAL CODE (CEC) • PART 4 - CALIFORNIA MECHANICAL CODE (CMC) • PART 5 - CALIFORNIA PLUMBING CODE (CPC) • PART 6 - CALIFORNIA ENERGY CODE (CENC) • PART 7 - (CURRENTLY VACANT) • PART 8 - CALIFORNIA HISTORICAL BUILDING CODE (CHBC) • PART 9 - CALIFORNIA FIRE CODE (CFC) • PART 10 - CALIFORNIA EXISTING BUILDING CODE (CEBC) • PART 11 - CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN) • PART 12 - CALIFORNIA REFERENCE STANDARDS CODE FS M WM POC FLOOR SINK WATER METER CONNECT TO EXISTING F. ALL DOMESTIC WATER HEATING, RECIRCULATING, FILTER AND SOFTENING EQUIPMENT SHALL BE TESTED AND/OR ADJUSTED AND BALANCED BY THE CONTRACTOR'S TESTING, ADJUSTING AND BALANCE AGENT (SEE TESTING ADJUSTING AND BALANCING) OR THE MANUFACTURER'S CERTIFIED STARTUP REPRESENTATIVE AFTER THE SYSTEM IS VERIFIED TO BE COMPLETE AND CORRECT BY STARBUCKS CXA IN ACCORDANCE WITH THE REQUIREMENTS OF THESE DOCUMENTS. SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH THE CONTRACT REQUIREMENTS. DELIVERABLES: PRELIMINARY, WRITTEN FUNCTIONAL PERFORMANCE REPORT CONFORMING TO THE REQUIREMENTS SPECIFIED HEREIN, DOCUMENTING THE INFORMATION SPECIFIED, ETC. TO THE STARBUCKS CXA IMMEDIATELY UPON COMPLETION OF THE WORK. G. CONTRACTOR SHALL INFORM STARBUCKS CXA WHEN EQUIPMENT IS READY FOR FUNCTIONAL PERFORMANCE TESTING. ALL EQUIPMENT SHALL BE READY FOR FUNCTIONAL PERFORMANCE TESTING PRIOR TO STARTING TESTING. CONTRACTOR SHALL OPERATE EQUIPMENT FOR STARBUCKS CXA AND VERIFY BY DEMONSTRATION THE CORRECT OPERATION OF EQUIPMENT, RESPONSE OF SENSORS, AND PROPER EXECUTION OF HVAC CONTROL AND LIGHTING SEQUENCES; INCLUDING BUT NOT LIMITED TO, AIR MOVEMENT, TEMPERATURE, SOUND, AND CONTROL RESPONSE. PROVIDE ANY SECURITY ACCESS, HARDWARE, SOFTWARE, OR OTHER SUPPORT AS NEEDED FOR THE STARBUCKS CXA TO EFFICIENTLY WITNESS AND DOCUMENT ALL EQUIPMENT TESTING. STARBUCKS CXA WILL RECORD THE EQUIPMENT OPERATION AND RESPONSE TO TESTING SEQUENCES AND PREPARE A LIST OF ANY DEFICIENCIES DISCLOSED BY THE FUNCTIONAL PERFORMANCE TESTS FOR CORRECTION BY THE CONTRACTOR. EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, AIR HANDLING UNITS, ROOFTOP AND SPLIT TYPE, CONDENSING UNITS, EXHAUST FANS, LIGHTING CONTROLS, ETC. DELIVERABLES: PROVIDE COMPLETED COPIES OF ALL START UP REPORTS, FILLED OUT ON THE MANUFACTURER'S FORMS, TO THE STARBUCKS CXA. H. CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ISSUES OR DEFICIENCIES DISCLOSED DURING THE FUNCTIONAL PERFORMANCE TESTING PROCESS. CORRECTIONS SHOULD BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION TO THE SYSTEM AND CONSTRUCTION SCHEDULE. I. CONTRACTOR SHALL BE READILY AVAILABLE FOR ANY RE- TESTING OF EQUIPMENT DEEMED NECESSARY BY STARBUCKS CXA DURING INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE TESTING. CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ISSUES OR DEFICIENCIES FOUND IN THE SYSTEM DURING ANY AND ALL RE-TESTING. CORRECTIONS SHOULD BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION TO THE SYSTEM AND CONSTRUCTION SCHEDULE. DELIVERABLES: FINAL BALANCE REPORT, DEFICIENCIES LIST NOTING CORRECTIVE ACTIONS PERFORMED BY CONTRACTOR IN RESPONSE TO INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE TEST RESULTS. J. CONSTRUCTION AND POST CONSTRUCTION TESTING: ADDITIONAL TESTING MAY BE REQUIRED BY LEED AND OTHER PROCESSES THAT MAY OCCUR OUT OF SEQUENCE WITH COMMISSIONING SERVICE. CONTRACTOR SHALL CONDUCT, DOCUMENT, SUPPORT AND SCHEDULE THIS TESTING AS DIRECTED BY STARBUCKS CXA. FCO WCO WALL CLEANOUT FLOOR CLEANOUT GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GW GREASE WASTE S SHOCK ABSORBER STRAINER HB HOSE BIBB D. INSTALLATION VERIFICATION SHALL BE PERFORMED BY STARBUCKS CXA. CONTRACTOR SHALL SUPPORT STARBUCKS CXA INSTALLATION VERIFICATION EFFORTS AS NECESSARY. PROVIDE ALL ACCESS AND EQUIPMENT NECESSARY FOR STARBUCKS STAFF TO VERIFY THAT THE EQUIPMENT IS INSTALLED CORRECTLY. E. CONTRACTOR SHALL BE READILY AVAILABLE DURING INSTALLATION VERIFICATION TO CORRECT ANY DEFICIENCIES OR DEFECTS DISCLOSED BY THE INSTALLATION VERIFICATION PROCESS. CORRECTIONS SHALL BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION OF THE CONSTRUCTION SCHEDULE. CH. V RV CHECK VALVE RELIEF VALVE BV GV BALL VALVE GATE VALVE TW RO RD G RS TW RO G RD RS TEMPERED WATER REVERSE OSMOSIS WATER GAS PIPING REFRIGERANT DISCHARGE PIPING REFRIGERANT SUCTION PIPING GW CD S OR W S OR W V CD GW CW HW CWF CWN CWS CWF CWN CWS SANITARY OR WASTE PIPING ABOVE SLAB SANITARY OR WASTE PIPING BELOW SLAB CONDENSATE DRAIN VENT PIPING HOT WATER PIPING GREASE WASTE COLD WATER PIPING COLD WATER FILTERED COLD WATER NANO FILTERED COLD WATER SOFTENED SYSTEM COMMISSIONING CONTRACTOR RESPONSIBILITIES FOR BUILDING COMMISSIONING CONTRACTOR SHALL PROVIDE SUPPORT AND WORK AS SPECIFIED, NEEDED AND REQUIRED TO CONDUCT AND FACILITATE STARBUCKS STAFF BUILDING COMMISSIONING EFFORTS. THIS WORK WILL BE COMPRISED OF THREE DISTINCT EFFORTS: 1) SUPPORT STARBUCKS COMMISSIONING AGENT (CXA) DURING INSTALLATION VERIFICATION AND CORRECT DISCLOSED DEFICIENCIES; 2) PERFORM TESTING, ADJUSTING, BALANCING AND SYSTEM STARTUP AND SUPPORT FUNCTIONAL PERFORMANCE TESTING BY STARBUCKS CXA; 3) CORRECT DEFICIENCIES DISCLOSED BY FUNCTIONAL PERFORMANCE TESTING AND SUBMIT REPORTS. CONTRACTOR SHALL PERFORM AND PROVIDE THE FOLLOWING: A. SYSTEMS SUBJECT TO COMMISSIONING MAY INCLUDE, BUT ARE NOT LIMITED TO, DOMESTIC HOT WATER GENERATION. B. CONTRACTOR SHALL INCLUDE COMMISSIONING ACTIVITIES IN PROJECT SCHEDULE AND SHOW INTERVALS FOR PERFORMANCE OF WORK FOR WHICH CONTRACTOR IS RESPONSIBLE AND INTERVALS FOR WORK PERFORMED BY STARBUCKS CXA. CONTRACTOR SHALL SHOW RESOURCES FOR PERFORMING ALL WORK RELATED TO COMMISSIONING ACTIVITIES ON A LINE ITEM IN THE SCHEDULE OF VALUES. C. CONTRACTOR SHALL INSTALL EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER’S REQUIREMENTS AND ALL CONTRACT DOCUMENTS. ENSURE THAT ALL EQUIPMENT IS INSTALLED TOTALLY COMPLETE, AND ACCESSIBLE TO STARBUCKS CXA FOR INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE TESTING PRIOR TO THE SCHEDULED START OF INSTALLATION VERIFICATION. VALVES GENERAL INSTALL VALVES FOR EACH FIXTURE AND ITEM OF EQUIPMENT. PROVIDE BRAIDED STAINLESS STEEL HOSE (UNLESS OTHERWISE NOTED) BETWEEN VALVE AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. LOCATE SHUT-OFF VALVES ADJACENT TO EQUIPMENT FOR EASY ACCESS SUCH THAT VALVES CAN BE REACHED WITHOUT MOVING EQUIPMENT. SHUT OFF VALVES TO BE BALL TYPE. VALVES SHALL BE LISTED/APPROVED FOR USE PER AUTHORITIES HAVING JURISDICTION (AHJ) AND CODE REQUIREMENTS. PROVIDE VALVE IDENTIFICATION PER THE PROJECT MANUAL FOR MAIN WATER SERVICE SHUT-OFF AND ANY OTHER VALVES WHICH ARE NOT CLEARLY EVIDENT WHAT THEY SERVE. PLUMBING FIXTURES WATER HEATER SIZE WATER HEATER PER STARBUCKS STANDARD AND PER AUTHORITIES HAVING JURISDICTION (AHJ), WHICHEVER IS MORE STRINGENT. PROVIDE INSTALLATION COMPLETE WITH FITTINGS AS SHOWN IN THE DRAWINGS. SET HOT WATER TEMPERATURE AT 140° F OR ADJUST AS REQUIRED BY AHJ. PROVIDE THERMOMETER ON HOT WATER PIPE LEAVING WATER HEATER. WATER FILTRATION STARBUCKS WATER FILTRATION VENDOR WILL PROVIDE FILTRATION SYSTEM. CONTRACTOR SHALL CONFIRM WITH STARBUCKS CONSTRUCTION MANAGER WHETHER VENDOR OR PLUMBING CONTRACTOR IS TO INSTALL FILTRATION SYSTEM. PROVIDE AND COORDINATE INSTALLATION COMPLETE WITH ALL PIPING, FITTINGS, AND EQUIPMENT AS INDICATED ON THE DRAWINGS. CONNECTIONS THE PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO EQUIPMENT INCLUDING REQUIRED MATERIAL SUCH AS PIPING, VALVES, FILTERS, TRAPS, CHECKS VALVES, VACUUM BREAKERS, AND FLEXIBLE AND RIGID TUBING. SCHEDULES REFER TO SCHEDULES ON DRAWINGS FOR A DESCRIPTION OF LISTED ITEMS AND FURNISH ANY AND ALL PLUMBING FIXTURES LISTED AS "GC". ANY DISCREPANCIES ABOUT WHO IS TO PROVIDE PLUMBING FIXTURES IN THE SCHEDULE SHALL BE BROUGHT TO STARBUCKS ATTENTION FOR CLARIFICATION. SUPPLIES. INSTALL ALL FIXTURES LISTED REGARDLESS OF WHO DISHWASHER G.C. TO FURNISH AND INSTALL POWER CORD FOR DISHWASHER PER JURISDICTIONAL REQUIREMENTS.IF EQUIPMENT IS SPECIFIED AS HOBART ADVANSYS, THE UNIT IS TO BE PLUMBED WITH COLD, NON- FILTERED WATER.IF THE WATER FILTRATION SYSTEM IS A PENTAIR CONFIGURATION II OR III, THEN THE COLD, NON-FILTERED WATER MUST ALSO BE SOFTENED. INSULATION WATER PIPING PROVIDE THERMAL INSULATION PER THE SPECIFICATIONS. SAFETY COVERS FURNISH AND INSTALL SPECIFIED NO SCALD SAFETY COVERS WITH INSULATED FOAM LINER AND TAMPER PROOF STRAP AT ALL EXPOSED ADA SINK P-TRAPS AND WATER SUPPLIES AND AS REQUIRED BY JURISDICTION . PIPING CONDENSATE DRAINAGE PIPING THE PLUMBING CONTRACTOR SHALL PROVIDE CONDENSATE DRAINS FOR AIR HANDLING UNITS AND STARBUCKS EQUIPMENT (REFER TO SCHEDULE). CONDENSATE DRAINAGE PIPING SHALL BE TYPE "M" COPPER TUBING WITH WROUGHT COPPER SWEAT FITTINGS JOINED WITH 50/50 SOLDER. TESTING ALL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE THEY ARE BACKFILLED OR CONCEALED. AFTER TESTING IS COMPLETE, THE PLUMBING CONTRACTOR SHALL DISINFECT THE POTABLE WATER SYSTEM AS REQUIRED BY LOCAL AUTHORITY. TEST WATER PURITY ACCORDING TO LOCAL REQUIREMENTS AND SUBMIT CERTIFIED TEST RESULTS TO ENGINEER FOR REVIEW AND APPROVAL. CARBONATION IF APPLICABLE TO PROJECT SCOPE FOR CBE STATION, STARBUCKS CARBONATION VENDOR WILL PROVIDE AND INSTALL EQUIPMENT, CO2 TANKS AND FITTINGS. STARBUCKS SHALL PROVIDE AND CONTRACTOR SHALL INSTALL CO2 TANK MOUNTING BRACKET, PROTECTIVE SHELVING UNIT AND CO2 GAS TUBING AS SHOWN ON DRAWINGS AND PER MANUFACTURER’S INSTRUCTIONS. MAXIMUM TUBING LENGTH INCLUDING COILED ENDS IS 100 FT (30 M) AND MAXIMUM BEND IS TO 3 INCH (75 MM) MINIMUM RADIUS. ROUTE CO2 TUBING PREFERABLY THROUGH WALL AND/OR CEILING CAVITIES, WITHOUT KINKS AND SO AS TO NOT TOUCH ANY HOT SURFACE (BALLAST, STEAM PIPE, ETC.) OR RUB AGAINST A SHARP EDGE THAT MAY ABRADE OR CUT TUBING. ALL HOLES MUST BE SEALED WITH A GROMMET OR ESCUTCHEON. TUBING IS TO BE SECURED TO APPROPRIATE PERMANENT SURFACES TO KEEP IT OFF THE FLOOR OR CABINET BOTTOMS AND AWAY FROM OTHER EQUIPMENT. LABEL BOTH ENDS OF TUBING AND REGULARLY AT TEN (10) FOOT INTERVALS ALONG ROUTE AS “CO2.” NITROGENATION STARBUCKS NITROGENATION VENDOR WILL PROVIDE AND INSTALL EQUIPMENT AND FITTINGS IF APPLICABLE TO PROJECT SCOPE FOR NITRO STATION. GENERAL CONTRACTOR SHALL COORDINATE NITRO SYSTEM INSTALLATION WITH STARBUCKS VENDOR. GENERAL PLUMBING NOTES 1. PLUMBING CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF WORK. 2. EXPOSED/SURFACE MOUNTED PIPING IS ONLY ALLOWED IN THE BAR AREA UNDER COUNTERTOPS, WHERE IT DOES NOT OBSTRUCT CABINETS/DEVICES AND WHERE APPROVED BY STARBUCKS CONSTRUCTION MANAGER. IF ROUTED THROUGH CABINETS, IT SHALL BE ROUTED TO MAXIMIZE STORAGE SPACE AND BE PROTECTED FROM DAMAGE. 3. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR ARRANGEMENT OF SYSTEM(S). FURNISH AND INSTALL ALL COMPONENTS NEEDED WHETHER INDICATED OR NOT TO PROVIDE A COMPLETE AND OPERATING SYSTEM. OVERALL CASEWORK COMPONENT DIMENSIONING ON PLUMBING DETAILS ARE SHOWN FOR REFERENCE AND COORDINATION ONLY. 4. CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY OTHER TRADES, AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM ACTUAL BUILDING DIMENSIONS. 5. THE PLUMBING CONTRACTOR SHALL COORDINATE PLUMBING WORK WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR FIXTURES IN CASEWORK AND PLUMBING DETAILS. SEE THE PROJECT MANUAL FOR PLUMBING SPECIFICATION SECTIONS. 6. ALL PIPING AND/OR PLUMBING DEVICES SHALL BE SUPPORTED FROM STRUCTURE (NOT FROM HVAC DUCTS OR OTHER PIPES/CONDUITS). 7. WHEN BUNDLING SEVERAL INDIRECT WASTE LINES TO DRAIN INTO FLOOR SINK, A UNISTRUT IS REQUIRED FOR SECURING AND BRACING ALL LINES ABOVE THE DRAIN. 8. FURNISH AND INSTALL ALL NEEDED DRAIN LINES PER CODE (NOT ALL SHOWN).INSTALL DRAINS AT 2% SLOPE WHERE POSSIBLE WITHOUT DIPS OR SAGS. ALL INDIRECT DRAINS SHALL RUN SEPARATELY FROM EACH OTHER TO INDIRECT DRAIN RECEPTOR AND SHALL TERMINATE WITH AN AIR GAP PER CODE. 9. FURNISH AND INSTALL WALL CLEANOUTS AT ALL SINKS AND AS NEEDED PER CODE (NOT ALL SHOWN). 10. INSULATE ICE BIN DRAINAGE PIPES PER THE REQUIREMENTS IN THE PROJECT MANUAL. GENERAL NOTES SCOPE THE INTENT OF THE PROJECT MANUAL AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL PLUMBING SYSTEM. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, AND EQUIPMENT RELATED TO THE INSTALLATION OF THE PLUMBING WORK. SITE EXAMINATION THE CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE FIXTURES, EQUIPMENT, AND PIPING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE PLUMBING WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH THE APPROPRIATE PROVISIONS OF LISTING STANDARD IN EFFECT AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS. PERMITS AND FEES THE CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE PLUMBING WORK. WARRANTY THE CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. LANDLORD REQUIREMENTS PRIOR TO BID: THE CONTRACTOR SHALL COORDINATE WITH LANDLORD / BUILDING OWNER FOR ANY CONSTRUCTION REQUIREMENTS. CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH REQUIREMENTS AND ADHERE TO THEM. WHERE LANDLORD / BUILDING OWNER REQUIREMENTS ARE MORE STRINGENT THAN SHOWN IN THESE PLANS. LANDLORD / BUILDING OWNER REQUIREMENTS SHALL GOVERN. WATER HAMMER ARRESTORWHA 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 Revision Schedule Rev Date By Description March 24 CH E C K S E T - 0 3 / 2 2 / 2 0 2 4 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 TU S T I N & S A N T A CL A R A 76085-018 51969 CHARLIE CHANG AMY YANG MAGED GERGES PLUMBING GENERAL NOTES & LEGENDS P-001 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 5 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 Revision Schedule Rev Date By Description March 24 CH E C K S E T - 0 3 / 2 2 / 2 0 2 4 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 TU S T I N & S A N T A CL A R A 76085-018 51969 CHARLIE CHANG AMY YANG MAGED GERGES PLUMBING SCHEDULES & CALCULATIONS P-002 NOTE: ADDITIONS OR ALTERATIONS OR NEW PLUMBING FIXTURES AND FITTINGS SHALL NOT EXCEED THE MAXIMUM ALLOWABLE FLOW RATES SPECIFIED IN SECTION 5.303. MAXIMUM FIXTURE FLOW RATES (CGBSC SECTION 5.303.3) MAXIMUM FLOW RATE NONRESIDENTIAL LAVATORY FAUCETS 0.4 GPM @ 60 PSI KITCHEN FAUCETS 1.6 GPM @ 60 PSI METERING FAUCETS 0.2 GALLONS/CYCLE WATER CLOSETS 1.28 GALLONS/FLUSH DC 5030 61-113 B 12-32 5010 A 1-11 5005 FIXTURE UNITS HYDROTROL J.R. SMITH WHA SYMBOL 33-60 5020 EQUAL OR APPROVED WATER HAMMER ARRESTER SCHEDULE ELECTRIC WATER HEATER SCHEDULE (EXISTING) TAG QTY MANUFACTURE MODEL CAPACITY (GALLON) ELEMENT WATTAGE RECOVERY @90°F RISE (GPH) VOLTAGE(V) CONNECTION OPERATING WEIGHT (LBS) CW HW (E) EWH-1 1 AO SMITH DRE-52-100 50 18,000 82 208 1"1"120 MARK WCO FCO GCO TMV NOTES: 1. CONTRACTOR TO VERIFY THAT ALL PLUMBING FIXTURES ARE FOR INSTALLATION ON EXPOSED SLAB. 2. ALL FIXTURES ARE SUBJECT TO TENANT/ARCHITECT APPROVAL. 3. REFER TO ARCHIECT PLANS FOR COMPLETE LIST OF PLUMBING FIXTURES. FIXTURE W WALL CLEANOUT FLOOR CLEANOUT GRADE CLEANOUT THERMOSTATIC MIXING VALVE SEE - PLANS SEE - PLANS SEE - PLANS --1/2"1/2" -- -- -- ZURN WALL CLEANOUT MODEL Z1441-VP, DURA-COATED CAST IRON BODY, GAS AND WATERTIGHT, VANDAL PROOF SCREWS, OR EQUIVALENT. COORDINATE FINAL LOCATIONS AND FINISH WITH ARCHITECT. ZURN FLOOR CLEANOUT MODEL Z1400-VP, ADJUSTABLE LEVELING, GAS AND WATERTIGHT, VANDAL PROOF SCREWS, OR EQUIVALENT. COORDINATE FINAL LOCATIONS AND FINISH WITH ARCHITECT. ZURN GRADE CLEANOUT MODEL Z1400-DC, HEAVY DUTY, ADJUSTABLE LEVELING, GAS AND WATERTIGHT, VANDAL PROOF SCREWS, OR EQUIVALENT. COORDINATE FINISH WITH ARCHITECT. SYMMONS MAXLINE THERMOSTATIC MIXING VALVE MODEL 7-210-CK-D, W/ INTEGRAL CHECK VALVES AND WALL MOUNTING BRACKET, ASSE 1017 AND ASSE 1070 COMPLIANT. PROVIDE DIAL TYPE THERMOMETER ON TEMPERED WATER LINE AT TMV OULET AND SET @ 110°F. FIXURE ROUGH-IN DESCRIPTION ACCESSORY SCHEDULE V CW HW 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 5 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 Revision Schedule Rev Date By Description March 24 CH E C K S E T - 0 3 / 2 2 / 2 0 2 4 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 TU S T I N & S A N T A CL A R A 76085-018 51969 CHARLIE CHANG AMY YANG MAGED GERGES PLUMBING SCHEDULES & CALCULATIONS P-003 TY P E " K " C O P P E R PE X TY P E " M " C O P P E R TY P E " L " C O P P E R DW V C O P P E R SC H 1 0 S T A I N L E S S PV C S C H E D U L E 4 0 SC H 4 0 B L A C K S T E E L NO - H U B C A S T I R O N GR O O V E D T Y P E L C O P P E R PIPE MATERIAL SCHEDULE LEGEND B = BARE PIPE I = INSULATED H = HEAT TRACED SERVICE DOMESTIC WATER DOMESTIC HOT WATER NATURAL GAS MEDIUM PRESSURE GAS WASTE VENT STORM DRAIN OVERFLOW DRAIN TRAP PRIMER CONDENSATE GREASE WASTE ABOVE GRADE ABOVE GRADE BELOW GRADE LOCATION BELOW GRADE INSIDE, 4" & SMALLER INSIDE, 5" & LARGER INSIDE, 4" & SMALLER INSIDE, 5" & LARGER ABOVE GRADE ABOVE GRADE BELOW GRADE INSIDE BELOW GRADE ABOVE INSIDE BELOW GRADE INSIDE BELOW GRADE B B B B B B B I I B N/A B B B B N/A N/A MATERIALS ADDITIONAL COMMENTS INSTALL 75 GPM (SCHIER GB-75) GREASE INTERCEPTOR WITH SAMPLING BOX. MARK GI-1 NOTES : 1. 4" PLAIN END INLET / OUTLET. 2. MAXIMUM OPERATING TEMPERATURE: 140 F CONTINUOUS 3. BUILT-IN FLOW CONTROL OR PROVIDE FLOW CONTROL DEVICE AS PER THE PLAN. 4. COVER PLACEMENT ALLOWS FULL ACCESS TO TANK FOR PROPER MAINTENANCE. 5. ENGINEERED INLET AND OUTLET DIFFUSERS ARE REMOVABLE TO INSPECT / CLEAN PIPING. 6. INTEGRAL AIR RELIEF / ANTI-SIPHON. 7. SIZING AND MODEL NUMBER ARE BASED ON TENANT'S REQUIREMENT. 31 GALLONS 125 GALLONS FLOW RATE (GPM)LOCATION 75 REFER TO SHEET PS-100 FOR EXACT LOCATION. PIPE CONNECTION 4 INCH MANU SCHIER GB-75 47" X 33" X 40" HYDRO-MECHANICAL GREASE INTERCEPTOR SCHEDULE WEIGHT (LBS) 190 SAMPLING BOX SPECIFICATION PROVIDE SCHIER MAKE SAMPLE BOX MODEL SV10 FLOW CONTROL DEVICE SPECIFICATION PROVIDE ENDURA MAKE FLOW CONTROL DEVICE MODEL 4044275A OR EQUALS BY OWNER APPROVAL. SOLIDS CAPACITY LIQUID CAPACITY MODEL SIZE ( L X W X H) 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 5 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 RETAIL SEATING AREA UNISEX CUSTOMER RESTROOM UNISEX PARTNER RESTROOM PARTNER / MANAGER AREA BACKBAR WORKROOM 10597 HS-1 10152 10549 DS-1 11871 WC-1 LAV-1 10116 21352 10549 10152 11871 WC-1 LAV-1 10116 21352 10153 10215 17565 RS-1 10597 11003 CRS-1 22642 22768 10153 13700 10804 10447 3CS-1 13588 14688 10995 10922 MS-1 FD-1 10594 FD-1 10594 HS-1 DS-1 (E) WFS-1 (E) DW-1 7 5 (E) EM-1 5 (E) EM-1 11003 CRS-1 22642 22768 10153 23443 5 OVEN COMBI HS-1 3 3 3 (E) EWH-1 8 4 23355BP-1 (E) WATER SOFTENER 6 RCP-1 2 5 3DB-15 22885 (E) IM-1 (E) RO-1 9 9 BELOW FLOOR TP 10 TP 10 1/2" 1/2"HW 120° CW 3/ 4 " 3/ 4 " HW 1 2 0 ° CW 3/4"HW 140° 3/4"HW 120° 3/4"HWR 3/ 4 " 1/2"HW 120°1/2"CW 3/4"CW 3/4"CW 1/ 2 " 1/ 2 " HW 1 2 0 ° HW R HW 1 2 0 ° HW R 3/ 4 " HW 1 4 0 ° HW 1 2 0 ° HW R 3/ 4 " 3/ 4 " HW 1 2 0 ° HW R 3/ 4 " HW 1 4 0 ° 1/ 2 " CF W 3/ 4 " 1- 1 / 4 " 3/ 4 " 11 CW 1- 1 / 4 " 1 3 CW 1- 1 / 4 " 1"HW 120°3/4"HW 120° CW3/4"CFW3/4" CW1-1/4"CFW1/2" CW1-1/4"CFW1/2" 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 Revision Schedule Rev Date By Description March 24 1S T P E R M I T S U B M I T T A L - 0 7 / 0 3 / 2 0 2 4 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 TU S T I N & S A N T A CL A R A 76085-018 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1 07/03/24 MZ 1st Round Of Comment N 1/4" = 1'-0"1PLUMBING WATER PLAN PLUMBING WATER PLAN P-100 1 PLUMBING PLAN KEY NOTES GENERAL NOTES ABBREVIATION LEGEND: 3CS-1 = 3-COMPARTMENT SINK CRS-1 = COUNTERTOP RAINSE SINK DB-1 = DUAL BREWER DS-1 = DUMP SINK DW-1 = DISH WASHER EM-1 = ESPRESSO MACHINE FD-1 = FLOOR DRAIN FS-1 = FLOOR SINK HS-1 = HAND SINK IM-1 = ICE MACHINE LAV-1 = LAVATORY MS-1 = MOP SINK RO-1 = REVERSE OSMOSIS WATER FILTER RS-1 = RINSE SINK WC-1 = WATER CLOSET WFS-1 = WATER FILLING STATION EWH-1 = ELECTRIC WATER HEATER 2 3 4 5 6 7 8 9 10 11 A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS. D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS OTHERWISE NOTED. E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2" (10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS. H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS LISTED IN THE PROJECT MANUAL. I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF WATER FILTRATION SYSTEM. J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW TO RENOVATED SYSTEMS. 1-1/4'' CW LINE CONNECT TO (E) EXISTING WATER METER. SEE PS-100 PLUMBING SITE PLAN FOR CONTINUATION. 3/4" CW, 3/4" CFW & 3/4" HW 120° DOWN WALL AND RUN BELOW GRADE. PROVIDE SHUT OFF VALVES AT WALL STUBS. PROVIDE ASSE 1070 THERMOSTATIC MIXING VALVE (TMV-2) SET AT 108° F TEMPERATURE TO MAINTAIN. PROVIDE ASSE 1070 THERMOSTATIC MIXING VALVE (TMV-1) SET AT 120° F TEMPERATURE TO MAINTAIN. PROVIDE ASSE 1012 APPROVED DUAL CHECK VALVE WITH ATMOSPHERIC VENT FOR EXPRESSO MACHINE, ICE MACHINE, OVEN COMBI AND DUAL BREWER. COLD WATER FROM WATER SOFTENER TO R.O. CONTROL SYSTEM AND WATER HEATER. EXISTING DISHWASHER MODEL NO.: LXEH FROM HOBART MANUFACTURER. RELOCATE EXISTING WATER HEATER AND PROVIDE NEW SUPPORT. PROVIDE ASSE 1010 OR PDI-WH 201 APPROVED WATER HAMMER ARRESTOR DEVICE FOR ALL QUICK-ACTING WATER VALVES. 1/2" CW TO TRAP PRIMER MODEL NO: TP300T FROM WATTS MANUFACTURER. BALANCING VALVE, CHECK VALVE AND ISOLATION VALVE AT HOT WATER RETURN CONNECTION TO HOT WATER LINE. A 5 A 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 2301 N Tustin Ave #A8/22/2024 RETAIL SEATING AREA UNISEX CUSTOMER RESTROOM UNISEX PARTNER RESTROOM PARTNER / MANAGER AREA BACKBAR WORKROOM (E) FCO (E) FCO 11871 WC-1 LAV-1 10116 21352 DS-1 10549 10152 11871 WC-1 LAV-1 10116 21352 10153 10215 17565 RS-1 HS-1 10594 11003 CRS-1 22642 22768 10153 DS-1 10549 10152 10594 13700 10804 10447 3CS-1 HS-1 13588 14688 10995 10922 23355 MS-1 FD-1 10594 FD-1 10594 (E) WFS-1 DW-1 (E)IM-1 (E) 4'' VTR (E) 4" SS (E) 4" SS (E ) 4 " S S (E ) 4 " S S HS-1 23443 OVEN COMBI 5 5 (E) 3" V (E) 3" V (E) 3" V (E ) 2 " V (E ) 2 " V (E ) 2 " V FCO 11003 CRS-1 22642 22768 10153 (E) EM-1 2 (E) EM-1 2 3 6 5 6 6 6 FCO 6 2% SLOPE 2% SLOPE 2% SLOPE 2 6 6 5 3" GW 3" GW 3" G W (E ) 4 " S S FCO 6 6 66 (E) 2" V (E) 4" SS 2% SLOPE 4" SS 2" V 2" V (E) 4 " S S 3" GW 2% SLOPE 2" V 5 2" V 2" V 2" V 4" SS4" SS (E ) 4 " S S 2% S L O P E 2% S L O P E 4" G W 2% S L O P E 4" G W 4" SS 4 1 1 2" V B.G. 2" V (E ) 4 " S S 3" V B.G. 1 6 6 5 (E) EWH-1 5 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 Revision Schedule Rev Date By Description March 24 1S T P E R M I T S U B M I T T A L - 0 7 / 0 3 / 2 0 2 4 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 TU S T I N & S A N T A CL A R A 76085-018 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1 07/03/24 MZ 1st Round Of Comment N 1/4" = 1'-0"1PLUMBING WASTE PLAN PLUMBING WASTE PLAN P-200 SEE PS-100 PLUMBING PLAN FOR CONTINUATION. INDIRECTLY DRAIN FIXTURE TO NEAREST FLOOR SINK. TERMINATE W/ 2" AIR GAP. 3" WASTE LINE FROM 3-COMPARTMENT SINK TERMINATE TO THE FLOOR SINK WITH AIR GAP CONNECTION. 3/4" TEMPERATURE AND RELIEF DRAIN TERMINATE OUT SIDE THE BUILDING. POINT OF CONNECTION OF NEW SANITARY SEWER PIPE TO EXISTING SANITARY SEWER PIPE.CONTRACTOR SHALL FIELD VERIFY ALL PIPE CONDITIONS PRIOR TO CONSTRUCTION , INCLUDING EXACT LOCATION, AVAILABLE INVERT, DIRECTION OF FLOW, AND CAPACITY FOR THE ADDED FIXTURE LOAD FROM THIS T.I.. POINT OF CONNECTION OF NEW VENT PIPE TO EXISTING VENT PIPE. CONTRACTOR SHALL FIELD VERIFY ALL PIPE CONDITIONS PRIOR TO CONSTRUCTION , INCLUDING EXACT LOCATION, AVAILABLE INVERT, DIRECTION OF FLOW, AND CAPACITY FOR THE ADDED FIXTURE LOAD FROM THIS T.I.. 3" GREASE VENT LINE UP TO ROOF AND TERMINATE ON THE ROOF WITH WEATHER PROTECTIVE CAP. 1 PLUMBING PLAN KEY NOTES GENERAL NOTES 2 3 4 5 6 A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS. D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS OTHERWISE NOTED. E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2" (10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS. H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS LISTED IN THE PROJECT MANUAL. I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF WATER FILTRATION SYSTEM. J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW TO RENOVATED SYSTEMS. 7 ABBREVIATION LEGEND: 3CS-1 = 3-COMPARTMENT SINK CRS-1 = COUNTERTOP RAINSE SINK DB-1 = DUAL BREWER DS-1 = DUMP SINK DW-1 = DISH WASHER EM-1 = ESPRESSO MACHINE FD-1 = FLOOR DRAIN FS-1 = FLOOR SINK HS-1 = HAND SINK IM-1 = ICE MACHINE LAV-1 = LAVATORY MS-1 = MOP SINK RO-1 = REVERSE OSMOSIS WATER FILTER RS-1 = RINSE SINK WC-1 = WATER CLOSET WFS-1 = WATER FILLING STATION EWH-1 = ELECTRIC WATER HEATER A 5 A 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 2301 N Tustin Ave #A8/22/2024 WC-1-1x3/4" (2.5) LAV-1-2x1/2" (1) DS-1-2x1/2" (1.5) WC-1-1x3/4" (2.5) LAV-1-2x1/2" (1) 3CS-1-2x3/4" (3)(E) DW-1-1x3/4" (1.5) (E) WFS-1-3x1/2" (1.5) HS-1-2x1/2" (1.5)DS-1-2x1/2" (1.5) (E) IM -1-1X1/2'' (0.5) DB-1-1x1/2" (0.5) HS-1-2x1/2" (1.5) MS-1-2x3/4" (3) (E) RO-1 (E) WATER SOFTENER BP-1 (E) EM-1-1x1/2" (0.5) (E) EM-1-1x1/2" (0.5) CRS-1-3x1/2" (1.5) CRS-1-3x1/2" (1.5) RS-1-3x1/2" (1.5) OVEN COMBI 2x1/2" (0.5) HS-1-2x1/2" (1.5) TMV-1 2 TMV-1 2 RCP-1 3/4" CW (2.5) 3/4" CW (2.5) 1/2" CW (1) 1/2" HW120°1/2" CW (1) 1/2" HW120° 1/2" CW (1.5) 1/2" HW120° 3/4" CW (3) 3/4" HW140° 3/4" HW140° 1/2" CW (1.5) 1/2" HW120° 1/2" HW120° 1/2" CW (1.5) 1/2" CW (1.5) 1/2" HW120° 3/4" CW (3) 3/4" HW140° 1/2" CW (1.5) 1/2" HW120° 1/2" CFW 3/4" CW B.G. (4) 3/4" HW120° B.G. 3/4" CFW B.G. 1/2" HW120° 1/2" CW (1.5) 1/2" CW (0.5) (E) EWH-1 1-1/4" CW (25.5) 1/2" HW120° 1-1/4" CW (14.5) 3/4" HW120° 3/4" CW (7.5) 3/4" HW120° 3/4" HW140° 1-1/4" CW (12.5) 3/4" HW140° 1/2" CFW 3/4" HWR 3/4" HWR 1" HW120° 1-1/4" CW (14) 3/4" HW140° 3/4" CW (10.5) 1-1/4" CW (22) 3/4" HW120° 3/4" HWR 3/4" CW (3.5) 1/2" HW120° TMV-1 2 TMV-1 2 TMV-1 2 1/2" CFW DUAL CHECK VALVE DUAL CHECK VALVE 1/2" HW120° 3/4" CFW TMV-2 3 3 1/2" CFW 3/4" HWR 1-1/4" CW (16) 3/4" HW120° 3/4" HW140° 1/2" CFW 3/4" HWR 1-1/4" CW (17.5) 3/4" HW120° 3/4" HWR 1 DUAL CHECK VALVE DUAL CHECK VALVE DUAL CHECK VALVE 3/4" CW (1.5) 1/2" HW120° 1-1/4" CW (30.5) 1-1/4" CW (27) 1/2" HW120° 3/4" HWR 1/2" CFW 1/2" CFW 4 5 1-1/4" CW (30.5) 3/4" CW (1.5) 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 Revision Schedule Rev Date By Description March 24 1S T P E R M I T S U B M I T T A L - 0 7 / 0 3 / 2 0 2 4 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 TU S T I N & S A N T A CL A R A 76085-018 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1 07/03/24 MZ 1st Round Of Comment 1PLUMBING WATER ISOMETRIC PLUMBING WATER ISOMETRIC P-400 GENERAL NOTES NTS PROVIDE ASSE 1070 THERMOSTATIC MIXING VALVE (TMV-2) SET AT 120° F TEMPERATURE TO MAINTAIN. PROVIDE ASSE 1070 THERMOSTATIC MIXING VALVE (TMV-1) SET AT 108° F TEMPERATURE TO MAINTAIN. PROVIDE ASSE 1010 OR PDI-WH 201 APPROVED WATER HAMMER ARRESTOR DEVICE FOR ALL QUICK-ACTING WATER VALVES. BALANCING VALVE, CHECK VALVE AND ISOLATION VALVE AT HOT WATER RETURN CONNECTION TO HOT WATER LINE. 1-1/4'' CW LINE CONNECT TO (E) EXISTING WATER METER. SEE PS-100 PLUMBING SITE PLAN FOR CONTINUATION. 1 PLUMBING PLAN KEY NOTES A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS. D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS OTHERWISE NOTED. E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2" (10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS. H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS LISTED IN THE PROJECT MANUAL. I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF WATER FILTRATION SYSTEM. J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW TO RENOVATED SYSTEMS. 2 3 4 ABBREVIATION LEGEND: 3CS-1 = 3-COMPARTMENT SINK CRS-1 = COUNTERTOP RAINSE SINK DB-1 = DUAL BREWER DS-1 = DUMP SINK DW-1 = DISH WASHER EM-1 = ESPRESSO MACHINE FD-1 = FLOOR DRAIN FS-1 = FLOOR SINK HS-1 = HAND SINK IM-1 = ICE MACHINE LAV-1 = LAVATORY MS-1 = MOP SINK RO-1 = REVERSE OSMOSIS WATER FILTER RS-1 = RINSE SINK WC-1 = WATER CLOSET WFS-1 = WATER FILLING STATION EWH-1 = ELECTRIC WATER HEATER 5 5 A 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 2301 N Tustin Ave #A8/22/2024 FCO (E) FCO HS(2) WCO DW FS (E) WFS(2) FS 3CS(6) HS(2) WCO MS(3) HS(2) FS CRS(2) FS CRS(2) LAV-1(1) LAV-1(1) FS IM(2) FS DS(2) FS RS(2) FD(2) FD(2) WC(4) WC(4) (E) 4"VTR (E) 4"SS (8) (E) 4"SS (8) (E) 4"SS (6) (E) 4"SS (4) (E) 4"SS (2) (E) 4"SS (17) (E) 4"SS (24) FS OVEN COMBI (2) 2"GW (2) 3"GW (4) 3"GW (6) 3"GW (11) 3"GW (13)3"GW (13) WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO DS(2) 4"GW (19) 4"GW (21) (E) 3"V (E) 3"V (E) 3"V (E) 3"V (E) 3"V (E) 2"V (E) 2"V (E) 2"V (E) 2"V (E) 2"V 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E (E) 2"V 1 WCO WCO WCO 2"GW (2) 2"GW (3) 2"GW (2) 3"GW (6) 2"GW (2) 2"V 2"V 2"SS (2) 2"V 4"SS (7) 2"SS (1) 4"SS (7) 4"SS (4) (E) 2"V (E) 2"V 2"V 2"V 2"V 2"V 2"V 2"V 2"V 2"V 2"V (E) 4"SS (10) (E) 4"SS (10) 3"GW (13) 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 2"V FCO (E) FCO WCO FCO (E) 4"SS (4) 2"GW (2) 2"GW (2) WCO 2"SS (1) 2"SS (3) 3" VTR 2 3 2" V B.G. 2" V B.G. 3 3 3 3 3 3 3 3 3 3 3 3 2 2 2 2 2 2 2% S L O P E (E) 4"SS (2) 2"V 2"V 2"V 2"V 2"V 2"V 2"V 2"V 2"V 2"V 2"V 2"V 2"V 2"V 2"V 2"V SAMPLE BOX SV-10 3"GW (19) WCO 1 GB-75 GREASE INTERCEPTOR GI-1 3" VTR 3" V B.G. 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 Revision Schedule Rev Date By Description March 24 1S T P E R M I T S U B M I T T A L - 0 7 / 0 3 / 2 0 2 4 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 TU S T I N & S A N T A CL A R A 76085-018 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1 07/03/24 MZ 1st Round Of Comment 1PLUMBING WASTE & VENT ISOMETRIC PLUMBING WASTE & VENT ISOMETRIC P-401 GENERAL NOTES NTS CONTRACTOR SHALL FIELD VERIFY ALL PIPE CONDITIONS PRIOR TO CONSTRUCTION , INCLUDING EXACT LOCATION, AVAILABLE INVERT, DIRECTION OF FLOW, AND CAPACITY FOR THE ADDED FIXTURE LOAD FROM THIS T.I.. POINT OF CONNECTION OF NEW SANITARY SEWER PIPE TO EXISTING SANITARY SEWER PIPE.CONTRACTOR SHALL FIELD VERIFY ALL PIPE CONDITIONS PRIOR TO CONSTRUCTION , INCLUDING EXACT LOCATION, AVAILABLE INVERT, DIRECTION OF FLOW, AND CAPACITY FOR THE ADDED FIXTURE LOAD FROM THIS T.I.. POINT OF CONNECTION OF NEW VENT PIPE TO EXISTING VENT PIPE. CONTRACTOR SHALL FIELD VERIFY ALL PIPE CONDITIONS PRIOR TO CONSTRUCTION,INCLUDING EXACT LOCATION, AVAILABLE INVERT, DIRECTION OF FLOW, AND CAPACITY FOR THE ADDED FIXTURE LOAD FROM THIS T.I.. 2 PLUMBING PLAN KEY NOTES 3 A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS. D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS OTHERWISE NOTED. E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2" (10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS. H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS LISTED IN THE PROJECT MANUAL. I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF WATER FILTRATION SYSTEM. J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW TO RENOVATED SYSTEMS. 1 ABBREVIATION LEGEND: 3CS-1 = 3-COMPARTMENT SINK CRS-1 = COUNTERTOP RAINSE SINK DB-1 = DUAL BREWER DS-1 = DUMP SINK DW-1 = DISH WASHER EM-1 = ESPRESSO MACHINE FD-1 = FLOOR DRAIN FS-1 = FLOOR SINK HS-1 = HAND SINK IM-1 = ICE MACHINE LAV-1 = LAVATORY MS-1 = MOP SINK RO-1 = REVERSE OSMOSIS WATER FILTER RS-1 = RINSE SINK WC-1 = WATER CLOSET WFS-1 = WATER FILLING STATION EWH-1 = ELECTRIC WATER HEATER 5 A 2N D P E R M I T S U B M I T T A L 0 7 / 0 2 / 2 0 2 4 2301 N Tustin Ave #A8/22/2024 CONFIGURATION III WATER FILTRATION SYSTEM. SEE CONFIGURATION III, R.O. AND SOFTENER DETAIL FOR MORE INFORMATION. R.O. PERMEATE TANK FRP ENCLOSED 6" ( 1 8 3 0 M M ) M I N . CL E A R 4' - 2 " ( 1 2 7 0 M M ) BA C K E R 2' - 6 " ( 7 6 5 M M ) 7' - 2 " ( 2 1 8 5 M M ) NOTE : 1. KEEP CLEAR AT BACKWALL FOR CHEMICAL DISPENSING SYSTEM COMPONENTS, TO BE INSTALLED BY SYSTEM VENDOR. REFER TO POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION 2' - 0 " ( 6 1 0 M M ) OPEN CEILING ABOVE WATER HEATER PER LOCAL CODE STRAP UNITS PER LOCAL CODE REQUIREMENTS PROVIDE MOISTURE- RESISTANT BLOCKING TO STRUCTURE BEHIND WALL FINISH AT THESE AREAS. REFER TO ITEM SPECIFICATIONS FOR PLUMBING SCOPE; COORDINATE INSTALL WITH FILTER VENDOR. FRP ENCLOSED HOT WATER TANK. SEE SPECIFICATIONS AND WATER HEATER TANK DETAIL FOR MORE INFORMATION. MOP HOLDER 3' - 0 " ( 9 1 5 M M ) 5' - 0 " ( 1 5 2 5 M M ) HOSE CLIP HOT AND COLD WATER SUPPLY FOR FAUCET MOP SINK SEE NOTE 1 BELOW SEE NOTE 1 BELOW 2'-0"(610MM) 6'-0"(1830MM) MIN. BLENDED STORAGE TANK ON WALL MOUNTED SHELF WATER BOOSTER PUMP SEE BOOSTER PUMP DETAIL FOR MORE INFORMATION. FRP ENCLOSED 9' - 6 " ( 2 8 9 5 M M ) T O B O T T O M O F B L E N D E D S T O R A G E T A N K S H E L F HOT WATER TANK (SEE SPECIFICATIONS & HOT WATER TANK DETAIL FOR FURTHER INSTALLATION REQUIREMENTS) 1" (25MM) BRASS CHECK VALVE EXPANSION TANK STRAP UNITS PER LOCAL REQUIREMENTS HOT WATER TO DISHWASHER (IF OTHER THAN HOBART ADVANSYS UNIT), BAR SINKS, MOP SINK AND COMPARTMENT SINK. 1" (25MM) HOT WATER OUTLET TEMPERED HOT WATER TO HAND SINKS TEMPERATURE MIXING VALVES UNION (TYP.)CONCEALED COPPER PIPING (TYP.) IF CONFIGURATION II OR III, SOFTENED COLD WATER TO DISHWASHER (IF HOBART ADVANSYS UNIT). SEE NOTE 2 BELOW. OPEN CEILING ABOVE WATER HEATER PER LOCAL CODE PAN AND DRAIN LINE FOR MAINTENANCE BOOSTER PUMP. SEE BOOSTER PUMP DETAIL FOR MORE INFORMATION. FL O W DI R E C T I O N NOTES : 1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. 2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND ADVANSYS DISHWASHER WHERE ALLOWED BY CODE. 3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES. 4.. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED.. FLOW DIRECTION 3/4" (20MM) CHROME ESCUTCHEONS (TYP.) 3/4" (20MM) BRASS THREADED BALL SHUT-OFF VALVE (TYP.) MAX 72" (1830MM) A.F.F. UNION (TYP.) 3/4" (20MM) FILTERED COLD WATER TO ICE MACHINE POINT OF USE FILTER LOCATED AT ICE MACHINE MOP SINK NOTES: 1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. GC TO COORDINATE INSTALLATION OF ALL OTHER COMPONENTS SHOWN WITH FILTER VENDOR. 2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND FROM SOFTNER TO ADVANSYS DISHWASHER WHERE ALLOWED BY CODE. 3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES. 4. PROVIDE WATER SOFTENER INDIRECT DRAIN TO SINK, INSTALLED PER CODE. (CONFIRM REQUIREMENTS WITH SOFTENER EQUIPMENT CUTSHEETS IN ITEM SPECIFICATIONS). 5. IN MUNICIPALITIES WITH BRINE RESTRICTIONS, REFER TO THE WATER SYSTEM CONFIGURATIONS APPENDIX UNDER ITEM SPECIFICATIONS FOR WATER SOFTENER EXCHANGE TANK SCHEMATIC. 6. COMPONENTS ARE TO BE POSITIONED TO MAXIMIZE ACCESS FOR REGULAR SERVICING. PRE-FILTER, BYPASS VALVES, AND SOFTENER TANKS MUST BE INSTALLED 72" (1828MM) AFF OR LOWER. R.O. PERMEATE TANK 7"(75MM) (180MM) 9 1/4"(75MM) (235MM) GFCI 120V QUAD RECEPTACLE FOR FILTER SYSTEM 77" (1955MM) A.F.F. (SEE NOTE 3)FILTERED COLD WATER TO FIXTURES (ESPRESSO MACHINES, BREWERS, HOT TAP, WATER TOWER FAUCET) 75 " ( 7 9 0 5 M M ) OUT R.O. CONTROL SYSTEM (SEE NOTE 5) 3/4" (20MM) SHUT-OFF VALVE 3/4" (15MM) FIP 3/4" (20MM) SHUT-OFF VALVE 3/4" (20MM) BYPASS 3/4" (20MM) SHUT-OFF VALVE CITY WATER IN TO NON FILTERED FIXTURES (TOILETS, HAND SINKS, DIPPER WELLS, BLENDER PITCHER RINSERS, IN-COUNTER RINSERS, BAR SINKS, HOSE BIBBS) 3/4" (20MM) FIP (FEMALE INTERNATIONAL PIPE THREAD FITTING) (TYP. 1 OF 2 TO SOFTENER) GFCI 120V RECEPTACLE FOR FILTER SYSTEM AT 54" (1372MM) A.F.F. (SEE NOTE 3) IN DIE EXCHANGE SYSTEM (EXISTING) WATER SOFTENER HEAD AND TANKS (BEHIND) DRAIN LINE FROM WATER HEATER TANK PAN ABOVE 11"(75MM) 255MM) 3"(75MM) WATER HEATER TANK SEE WATER HEATER TANK DETAIL FOR MORE INORMATION FROM WATER HEATER TANK TEMPERING VALVE OUT IN IN TO HOT WATER TANK AND ADVANSYS DISHWASHER PLUMBING. SEE WATER HEATER TANK DETAIL FOR MORE INORMATION BYPASS VALVE BLENDED STORAGE TANK ON WALL MOUNTED SHELF 5' - 0 " ( 7 5 M M ) TO R.O. SYSTEM BOOSTER PUMP BYPASS VALVE 3/4" (20MM) CITY WATER IN BOOSTER PUMP SHUT-OFF VALVE TO BOOSTER PUMP 3/4" (20MM) BOOSTED WATER IN 5' - 9 " ( 7 5 M M ) WATER FILTRATION BOOSTER PUMP. SEE BOOSTER PUMP DETAIL FOR MORE INFORMATION 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 Revision Schedule Rev Date By Description March 24 CH E C K S E T - 0 3 / 2 2 / 2 0 2 4 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 TU S T I N & S A N T A CL A R A 76085-018 51969 CHARLIE CHANG AMY YANG MAGED GERGES 1/2" = 1'-0"2CONFIGURATION III 3/4" = 1'-0"3WATER HEATER TANK - PLUMBING 1" = 1'-0"1CONFIGURATION III, R.O. AND SOFTENER WATER FILTRATION PLUMBING DETAILS P-500 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 5 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 1' - 2" SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION AND TYPE ICE BIN ABOVE INDIRECT DRAIN LINE FROM ESPRESSO MACHINE TO FLOOR SINK UNDERCOUNTER REFRIGERATOR INDIRECT DRAIN LINE FROM RINSER SINK TO FLOOR SINK UNDERCOUNTER CABINET INDIRECT AND INSULATED DRAIN LINE FROM ICE BIN ABOVE TO FLOOR SINK SUPPORT LEG (TYP.) 2' - 6 1 / 2 " UNDER COUNTER UNDERCOUNTER REFRIGERATOR NON-FILTERED COLD WATER SUPPLY FOR METERED SPOON RINSER NON-FILTERED COLD WATER SUPPLY FOR PITCHER RINSER ICE BIN RINSER SINK UNDERCOUNTER CABINET ABOVE COUNTER 5' - 9" UNDERCOUNTER BOILER FOR INSTANT HOT WATER FONT FILTERED COLD WATER SUPPLY FOR ESPRESSO MACHINE FILTERED COLD WATER SUPPLY FOR WATER TOWER DISPENSER FILTERED COLD WATER SUPPLY FOR INSTANT HOT/COLD WATER FONT * FILTERED COLD WATER SUPPLY FOR INSTANT HOT/COLD WATER BOILER * * ** PROVIDE WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE CONNECTION* **PROVIDE BACKFLOW PREVENTION DEVICE BEFORE PUMP AND WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE CONT. INDIRECT AND INSULATED DRAIN LINE FROM ICE BIN AT SECOND ESPRESSO BAR TO FLOOR SINK HERE CONT. INDIRECT DRAIN LINE FROM ESPRESSO MACHINE AT SECOND ESPRESSO BAR TO FLOOR SINK HERE HOT AND COLD WATER FOR SINK FAUCET AT 20 1/2" (520MM) A.F.F. SHUT- OFF VALVES AT WALL AND 4" (100MM) EITHER SIDE OF WASTE LINE.FILTERED COLD WATER SUPPLY FOR BREWER WITH SHUT-OFF IN CABINET AT 24" (610MM) A.F.F. 9'-3 1/2" * PROVIDE BACKFLOW PREVENTION DEVICE THEN WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE CONNECTION * 10" FLOOR SINK 2' - 5 1 / 2 " FL O O R S I N K SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION AND TYPE INDIRECT DRAIN LINE FROM RINSE SINK TO FLOOR SINK INDIRECT DRAIN LINE FROM BREWER TO FLOOR SINK DIRECT DRAIN LINE FROM SINK. ROUGH-IN SINK WASTE STUB AT 15 1/2" (394MM) A.F.F. AND CENTERLINE OF SINK TEMPERED HOT AND COLD WATER FOR SINK FAUCET AT 20 1/2" (520MM) A.F.F. SHUT-OFF VALVES AT WALL AND 4" (102MM) EITHER SIDE OF WASTE LINE. 1'-3" EQ EQ ELEVATION - PLUMBING DIAGRAM FLOOR SINK COLD WATER SUPPLY FOR COMBI OVEN CLEANING WITH SHUT- OFF IN CABINET AT 18" (457MM) A.F.F. FILTERED WATER SUPPLY FOR COMBI OVEN WATER INJECTION WITH SHUT- OFF IN CABINET AT 18" (457MM) A.F.F. PLAN - PLUMBING DIAGRAM 6'-6" FILTERED WATER SUPPLY FOR COMBI OVEN WATER INJECTION WITH SHUT-OFF IN CABINET AT 18" (457MM) A.F.F. COLD WATER SUPPLY FOR COMBI OVEN CLEANING WITH SHUT- OFF IN CABINET AT 18" (457MM) A.F.F. INDIRECT DRAIN LINE FROM COMBI OVEN TO FLOOR SINK SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION AND TYPE ICE BIN (TYP. 1 OF 2)NON-FILTERED COLD WATER SUPPLY FOR METERED SPOON RINSER (TYP. 1 OF 2) NON-FILTERED COLD WATER SUPPLY FOR PITCHER RINSER (TYP. 1 OF 2) RINSER SINK (TYP. 1 OF 2) UNDERCOUNTER REFRIGERATOR (TYP. 1 OF 2) 2' - 6 1 / 2 " 6'-0"4'-9 1/2" UNDERCOUNTER BOILER FOR INSTANT HOT WATER FONT (TYP 1 OF 2) INDIRECT DRAIN LINE FROM RINSER SINK TO FLOOR SINK (TYP.) INDIRECT DRAIN LINE FROM ESPRESSO MACHINE TO FLOOR SINK (TYP.) ICE BIN ABOVE WITH INDIRECT AND INSULATED DRAIN LINE TO FLOOR SINK BELOW UNDERCOUNTER REFRIGERATOR (TYP. 1 OF 2) COUNTERTOP ABOVE FLOOR SINK (TYP. 1 OF 2) SEE PLUMBING PLAN FOR FINAL LOCATIONS AND TYPE CABINETRY FRAME (TYP.) CABINETRY LEG (TYP.) INDIRECT DRAIN LINE FROM RINSER SINK TO FLOOR SINK (TYP.) INDIRECT DRAIN LINE FROM ESPRESSO MACHINE TO FLOOR SINK FILTERED COLD WATER SUPPLY FOR INSTANT HOT/COLD WATER FONT (TYP. 1 OF 2) * FILTERED COLD WATER SUPPLY FOR UNDERCOUNTER INSTANT HOT WATER BOILER (TYP. 1 OF 2) * FILTERED COLD WATER SUPPLY FOR WATER TOWER DISPENSER (TYP. 1 OF 2) * UNDER COUNTER ABOVE COUNTER FILTERED COLD WATER SUPPLY FOR ESPRESSO MACHINES (TYP. 1 OF 2) ** PROVIDE WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE CONNECTION* **PROVIDE BACKFLOW PREVENTION DEVICE BEFORE PUMP AND WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 Revision Schedule Rev Date By Description March 24 CH E C K S E T - 0 3 / 2 2 / 2 0 2 4 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 TU S T I N & S A N T A CL A R A 76085-018 51969 CHARLIE CHANG AMY YANG MAGED GERGES 3/4" = 1'-0"4ESP 10-02 PLUMBING 3/4" = 1'-0"5DTE 06-03 PLUMBING 3/4" = 1'-0"1BRW 09-01 PLUMBING 3/4" = 1'-0"3ADD-ON HAND SINK PLUMBING 3/4" = 1'-0"2AC WRM-20 PLUMBING PLUMBING DETAILS P-501 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 5 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 INDIRECT DRAIN LINE FROM ICE MACHINE TO FLOOR SINK SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION AND TYPE .6" (152MM) MIN. CLEAR TO BACK WALL INDIRECT DRAIN LINE FROM ICE BIN TO FLOOR SINK INDIRECT DRAIN LINE FROM ICE DIVERTER TO FLOOR SINK ICE MACHINE ICE TRANSPORT TUBE BETWEEN ICE MACHINE AND DIVERTER VALVE. MAX. LENGTH 10' (3M) ICE HEAD ADAPTER ICE MANAGER CONTROL PANEL ICE TRANSPORT TUBE LANE 2, TO ICE BIN. MAX LENGTH 75', MIN. SLOPE 1/4":1' ICE TRANSPORT TUBE LANE 1, TO ICE DISPENSER. MAX LENGTH 75', MIN. SLOPE 1/4":1' 3" PVC SLEEVE TO SUPPORT ICE TRANSPORT TUBEFASTENED TO WALL OR CEILING W/ STRAPING @ 48" O.C. MIN. ICE DIVERTER VALVE ELEVATION - PLUMBING DIAGRAM PLAN - PLUMBING DIAGRAM CONT. FRP TO CEILING ON BACK WALL OVER IN WALL BLOCKING ICE BIN ICE MACHINE ICE HEAD ADAPTER NOTE: INDIRECT DRAIN MIN. RADIUS = 8" ICE TRANSPORT TUB MIN. RADIUS = 6" NOTE: INDIRECT DRAIN MIN. RADIUS = 8" ICE TRANSPORT TUB MIN. RADIUS = 6" ECO-GRIP COVER BASE ACCESSIBLE CLEARANCE AT CONTROL PANEL ICE MANAGER CONTROL PANEL ICE DIVERTER VALVE CONT. FRP ON BACK WALL OVER IN WALL BLOCKING BACK WALL MIN. r 6" BIN TOP SENSOR DISTRIBUTION UNIT ICE BIN INDIRECT DRAIN LINE FROM ICE MACHINE TO FLOOR SINK 4' - 0" 2' - 6 " Plan View KEEP CLEAR FOR WALL MOUNTED CHEMICAL DISPENSING SYSTEM, TO BE INSTALLED BY SYSTEM VENDOR. PROVIDE BACKING BEHIND WALL FINISH FOR EQUIPMENT MOUNTING. REFER TO POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION. Elevation View SOFTENED HOT AND NON-FILTERED COLD WATER FOR SINK FAUCET INDIRECT DRAIN LINE FROM DISHWASHER TO NEAREST FLOOR SINK. BACK WALLDRAIN LINE FROM SINK TO WASTE LINE IN WALL OR TO FLOOR SINK SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION. FLOOR SINK OPTIONAL. WIRE RACK COMPARTMENT SINK DISHWASHER NOTE: FOR COORDINATION ONLY. SEE FURNITURE, FIXTURES, AND EQUIPMENT PLAN FOR EQUIPMENT LOCATIONS. PROVIDE BACKING BEHIND WALL FINISH AS REQUIRED FOR WALL MOUNTED EQUIPMENT. REFER TO ITEM SPECIFICATIONS FOR MORE INFORMATION. PRE-WASH STATION 4' - 0 " (1 2 2 0 M M ) 1' - 2 " (3 5 5 M M ) 4' - 6 " (1 3 7 0 M M ) DRAIN LINE FROM DISHWARE DRYING RACKS TO SINK BOWL DISHWARE DRYING RACKS WITH DRAIN LINE TO SINK BOWL ALIGN 3' - 1 1 " (1 1 9 5 M M ) 3' - 2 " (9 6 5 M M ) 11'-4"(3455MM) 3/4" PLYWOOD BACKER BOARD BEHIND WALL FINISH. FASTEN TO STRUCTURE BEYOND. 3 1/4" (80MM) WATER FOR DISHWASHER WITH SHUT-OFF UNDER SINK AT 18" (460MM) AFF. LINE LENGTH MUST ALLOW EASE OF MOVEMENT. VERIFY WATER REQUIREMENTS FOR TYPE OF DISHWASHER (HOT/COLD/SOFTENED). SEE WATER SUPPLY DRAWINGS FOR WATER LINE. IF ADVANSYS DISHWASHER, INCLUDE PRESSURE REDUCING VALVE. PRESSURE GAUGE (SET TO 20 PSIG +/- 5 PSI), LINE STRAINER AND SHOCK ARRESTOR. B MOP SINK AND WATER FILTRATION EQUIPMENT. SEE PLAN FOR ACTUAL CONFIGURATION. HOT WATER TANK SUPPORT PLATFORM PER ENGINEER'S DRAWINGS WATER HEATER TANK PER PLAN HOT WATER TANK CHASE TO STRUCTURE OR HARD LID ABOVE. PAINT INTERIOR GWB FINISH TO MATCH BOH FRP. ROOF STRUCTURE PER PLAN 2'-8" CLEAR 7' - 2 " BOTTOM OF WORKROOM CEILING IN FOREGROUND OPEN TO WORKROOM A SECTION A HOT WATER PIPING AND FLUE. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED. BO H C E I L I N G H E I G H T P E R P L A N 2" BOOSTER PUMP EXTEND BULKHEAD AND BACK SURROUNDING WALLS TO STRUCTURE ABOVE SECTION B ENSURE WATER TANK CHASE IS FULLY SEALED FOR PEST EXCLUSION 2'-8" CLEAR 7' - 2 " BO H C E I L I N G H E I G H T P E R P L A N 2" SECTION B 7' - 0 " PROVIDE HARD LID AT 7'-0" (2135MM) ABOVE TOP OF WATER HEATER TANK CHASE HOT WATER PIPING AND FLUE. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED. ROOF STRUCTURE PER PLAN PAINT CHASE INTERIOR GWB FINISH TO MATCH BOH FRP. WATER HEATER TANK PER PLAN HOT WATER TANK SUPPORT PLATFORM PER ENGINEER'S DRAWINGS MOP SINK AND WATER FILTRATION EQUIPMENT. SEE PLAN FOR ACTUAL CONFIGURATION. ENSURE WATER TANK CHASE IS FULLY SEALED FOR PEST EXCLUSION (ALTERNATE FOR TALL CEILING CONDITIONS) FILTERED COLD WATER SUPPLY FOR WATER TOWER FAUCET * FILTERED COLD WATER SUPPLY FOR INSTANT HOT/COLD WATER FONT NON-FILTERED HOT AND COLD WATER SUPPLY FOR SINK FAUCET ABOVE COUNTERTOP AT FLOOR LEVEL INDIRECT LINE FROM PREP SINK ABOVE TO FLOOR SINK SHELVING ABOVE FILTERED COLD WATER SUPPLY FOR UNDERCOUNTER INSTANT HOT WATER BOILER (LOCATION MAY VARY) ** PROVIDE WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE CONNECTION* 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 Revision Schedule Rev Date By Description March 24 CH E C K S E T - 0 3 / 2 2 / 2 0 2 4 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 TU S T I N & S A N T A CL A R A 76085-018 51969 CHARLIE CHANG AMY YANG MAGED GERGES 3/4" = 1'-0"1PLUMBING - NUGGET ICE - PEDESTAL STACK 3/4" = 1'-0"2SANITIZING (GENERIC) - PLUMBING 3/8" = 1'-0"3WATER HEATER TANK CHASE 3/4" = 1'-0"4WATER FILLING STATION - PLUMBING PLUMBING DETAILS P-502 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 5 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 3' - 3" (915MM) 8' - 9 " ( 2 6 7 0 M M ) A. F . F . NOTES : 1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. 2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND ADVANSYS DISHWASHER WHERE ALLOWED BY CODE. 3. POSITION BOOSTER PUMP SO THAT PRESSURE GAUGE IS READABLE AND ACCESSIBLE FOR TROUBLESHOOTING AND MAINTENANCE. 4. BOOSTER PUMP STATIC AND DYNAMIC OUTLET PRESSURE SHALL BE BETWEEN 65 TO 70 PSI. VERIFY PER PUMPS INTEGRAL PRESSURE GAUGE. 5. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES. 6. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED. 7. PROVIDE VIBRATION DAMPENING AT BOOSTER PUMP MOUNT TO PLATFORM. WATER HEATER TANK. SEE WATER HEATER TANK DETAIL FOR MORE INFORMATION. GFCI 120V RECEPTACLE FOR BOOSTER PUMP MIN. CLEAR 2" (50MM)CITY WATER IN OUT TO WATER FILTRATION SYSTEM BOOSTER PUMP. SECURE TO SHELF BELOW WITH BOLTS THROUGH BASE PLATE SHELF PER ENGINEER'S DRAWINGS (3 0 5 M M ) 1' - 0 " (6 1 0 M M ) 2' - 0 " (6 1 0 M M ) 2' - 0 " (1 7 8 0 M M ) 5' - 7 1 / 2 " MOP SINK HOT AND COLD WATER SUPPLY FOR MOP FAUCET HOSE CLIP WIRE RACK STRAP UNITS PER LOCAL CODE REQUIREMENTS MOP HOLDER FRP ENCLOSED CHEMICAL DISPENSING SYSTEM COMPONENTS, TO BE INSTALLED BY SYSTEM VENDOR. REFER TO POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION. PAN AND DRAIN FOR MAINTENANCE WATER HEATER TANK WATER HEATER TANK PLATFORM CEILING IN-WALL CONTINUOUS CONDUIT FASTENED W/ STRAPING @ 48" O.C. MIN. ICE TRANSPORT TUBE LANE 1, TO ICE DISPENSER. MAX LENGTH 75', MIN. SLOPE 1/4":1' 1' - 1 " 4' - 8 1 / 2 " OUTLET BOX FOR INDIRECT DRAIN LINE FLOOR SINK OUTLET BOX FOR INDIRECT DRAIN LINE IN-WALL INDIRECT DRAIN LINE FROM ICE DISPENSER TO FLOOR SINK SECTION A - PLUMBING DIAGRAM SKIRT TO DOOR FACE W/ TAPERED EDGE PULL MOUNTING TEMPLATE, BLACK IN-WALL BLOCKING REQUIRED, PROVIDED BY G.C. OUTLET BOX FOR INDIRECT DRAIN LINE 11'-8"INDIRECT LINE FROM DRAINBOARD TO FLOOR SINK HOT AND NON-FILTERED COLD WATER FOR SINK FAUCET AT 20 1/2" (20MM) A.F.F. SHUT-OFF VALVES AT WALL AND 4" (100MM) EITHER SIDE OF WASTE LINE NON-FILTERED COLD WATER SUPPLY FOR BLENDER PITCHER RINSER INDIRECT DRAIN LINE FROM SINK TO FLOOR SINK FILTERED COLD WATER SUPPLY FOR WATER TOWER FAUCET CEILING IN-WALL INDIRECT DRAIN LINE FROM ICE DISPENSER TO FLOOR SINK OUTLET BOX FOR INDIRECT DRAIN LINE OUTLET BOX FOR INDIRECT DRAIN LINE FLOOR SINK DRAIN LINES FROM DRAIN TRAY AND UNDERCOUNTER REFRIGERATOR; SEPARATE, INDIRECT TERMINATION AT FLOOR SINK SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION AND TYPE ELEVATION - PLUMBING DIAGRAM A ICE TRANSPORT TUBE LANE 1, TO ICE DISPENSER. MAX LENGTH 75', MIN. SLOPE 1/4":1'. IN-WALL CONTINUOUS CONDUIT FASTENED W/ STRAPING @ 48" O.C. MIN. VA R I E D 1" = 1'-0"3BOOSTER PUMP - PLUMBING 3/4" = 1'-0"2MOP SINK (STACKED) - PLUMBING 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 Revision Schedule Rev Date By Description March 24 CH E C K S E T - 0 3 / 2 2 / 2 0 2 4 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 TU S T I N & S A N T A CL A R A 76085-018 51969 CHARLIE CHANG AMY YANG MAGED GERGES 3/4" = 1'-0"1CBE 15-01 PLUMBING PLUMBING DETAILS P-503 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 5 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 Revision Schedule Rev Date By Description March 24 CH E C K S E T - 0 3 / 2 2 / 2 0 2 4 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 TU S T I N & S A N T A CL A R A 76085-018 51969 CHARLIE CHANG AMY YANG MAGED GERGES PROVIDE ONE PIECE SPUN ALUMINUM BASE WITH, GRADUATED STEPPED PVC BOOT, AND ADJUSTABLE STAINLESS STEEL CLAMPS. SET BASE IN BED OF MASTIC FLOOR SLAB ON GRADE REFER TO ARCHITECT'S DRAWING FOR APPLICATION INSTALLATION WITH OF VENT PIPE BOOT ROOFING MATERIAL ROOF INSULATION ROOF DECK OF ROOF DECK PROVIDE SLEEVE IF ANCHOR PIPE TO ROOF MINIMUM 12" BELOW ROOF REQUIRED BY TYPE PROVIDE PIPE INCREASER WHERE REQUIRED TO MAKE MINIMUM 3" VENT THRU ROOF DECK OR JOISTS WITH WELDED OR SCREWED U-BOLT AROUND PIPE AND ANGLE IRON TO DECK OR JOIST HUBLESS PIPE CONNECTORS ON CAST IRON PIPE REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR MINIMUM TEN FEET HORIZONTAL OR THREE FEET VERTICAL ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, AND ONE FOOT FROM ANY VERTICAL SURFACE. PROVIDE 1" FIBERGLASS INSULATION WITH ALL- SERVICE JACKET ON VENT PIPE INSIDE BUILDING WITHIN SIX FEET OF VENT THRU ROOF LOCATION. VERIFY FLASHING AND COUNTERFLASHING WITH ROOFING CONTRACTOR. NOTES: 1. 2. 3. 4. 5. 6. 7. 5 VENT THRU ROOF 12" = 1'-0"4 NO-HUB SEE SCHEDULE SANITARY OR STORM SEWER LINE LONG SWEEP ELBOW AT END OR TURN OF RUN DIRECTION OF FLOW COMBINATION WYE AND EIGHTH BEND IN RUN. ENTER TOP OF PIPE MINIMUM 12" ABOVE ROOF DEPTH OF SEWER AS REQUIRED FOR SAME SIZE AS SEWER UP TO 4" MAXIMUM MEMBRANE CLAMP PROVIDE ROUND SECURED NICKEL BRONZE ADJUSTABLE TOP WITH "CO" CAST IN COVER. PROVIDE CLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). PROVIDE BRONZE PLUG IN CAST IRON BODY. LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE GREATER THAN 45 DEGREES, AT 50' INTERVALS ON STRAIGHT RUNS, AND WHERE SHOWN ON PLANS. PROVIDE BACKFILL PER ARCHITECTURAL SPECIFICATIONS. LOCATE CLEANOUTS WHERE THERE IS 18" CLEAR AROUND. CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS. FLOOR CLEANOUT 12" = 1'-0" 1/2" TEMPERED HW SUPPLY THERMOSTATIC MIXING VALVE SET TEMPERATURE TO 110°F P-TRAP 1/2" CW SUPPLY PROVIDE METAL 360° INSULATION SHIELD AND HIGH DENSITY INSULATION OR PRE-ENGINEERED THERMAL HANGER SHIELD INSERT OF CALCIUM SILICATE INSULATION. FOR PIPES 4" AND SMALLER PRE-ENGINEERED THERMAL HANGER SHIELD INSERT OF FLEXIBLE UNICEULAR INSULATION MAY BE PROVIDED CUT INSULATION TO FIT AROUND TRAPEZE HANGER. SEAL BOTH ENDS OF EXPOSED INSULATION WITH JOINT SEALANT SIZE AND QUANTITY OF HANGER RODS PER MANUFACTURER'S RECOMMENDATIONS PROVIDE TWO-PIECE PIPE CLAMP (TYP) SUPPORT NUT (TYP) UNINSULATED STEEL OR PLASTIC PIPE UNINSULATED COPPER PIPE PROVIDE PLASTIC GALVANIC ISOLATOR FOR COPPER PIPE (TYP) COLD INSULATED PIPE TMV - 1/2" HW NOTES: 1. NOTES: 1. 2. SEE MATERIAL MATRIX FOR PIPE MATERIAL AND JOINING METHOD. TMV TO HAVE A MINIMUM FLOW LESS THAN OR EQUAL TO ONE FAUCET'S MINIMUM FLOW LAVATORY TAILPIPE AND HOT WATER LINES SHALL BE INSULATED OR COVERED PER CBC 11B-606.5. 2. 3. 4. 5. 6. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. REFER TO SPECIFICATIONS FOR MORE INFORMATION. PIPE AND CONDUIT OF ALL TRADES MAY BE COMBINED ON THE SAME SUPPORT CHANNEL. COORDINATE SUPPORT CHANNEL LENGTH WITH PIPING AND CONDUIT TO BE SUPPORTED. SUPPORT CHANNEL SPACING SHALL BE DETERMINED BY SMALLEST PIPE TO BE SUPPORTED. CHANNEL SUPPORT MAY BE USED AS A WALL BRACKET, ATTACH TO WALL WITH ANCHOR BOLTS PER SPECIFICATIONS. FOR HORIZONTAL INSULATED PIPING, ATTACH CLAMPS AS INDICATED ABOVE, FOR VERTICAL INSULATED PIPING, ATTACH CLAMPS TO THE PIPE AND SEAL INSULATION AT BOTH CLAMP ENDS. 3 PUBLIC LAVATORY & HAND SINK W/ TMV 1" = 1'-0"1 MULTIPLE PIPE TRAPEZE HANGER 12" = 1'-0" ANCHOR - PER NFPA 6 PIPE HANGAR 12" = 1'-0" ON INSULATED PIPE. PROVIDE PIPE SUPPORT SHIELD. HANGER - GRINNEL FIG. 69 3/8" ALL-THREAD ROD FOR <=4" PIPE. FOR LARGER PIPE SIZES SEE NFPA 13. NOTE: BUILDING STRUCTURE MAY VARY MATCH INSTALLATION TO BUILDING STRUCTURE REFER TO STRUCTURAL DRAWINGS FOR ATTACHMENT. 1/2" CW PROVIDE 1-5/8"x1-5/8" 14 GA. CHANNEL SUPPORT PIPE INSULATION (TYP) HOT INSULATED PIPE 2 ECO-GRIP CLAMPING FLOOR SINK DETAIL 12" = 1'-0" 3" TAIL PIECE NO-HUB CONNECTION GRAVEL BACKFILL CONC INFILL AND TRENCH FOR BELOW GRADE UTILITIES STAINLESS STEEL FLOOR SINK W/CLAMPING FEATURE FLOOR SINK HALF GRATE FLUSH WITH FLOOR FINISH 3. PLUMBING DETAILS P-504 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 5 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024 1 1 2 2 (E) 4" SS (E) 2'' BFP (E) 2'' WATER METER 3 GI-1 4 2 GB-75 GREASE INTERCEPTOR 3" V B.G. SAMPLE BOX SV-10 3 PETERS CANYON RD. STE 110 IRVINE, CA 92606 D G ESI N | ARCHITECTURE H E S T I A A T E L I E R SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2020 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: STARBUCKS TEMPLATE VERSION: i2021.04.23 Revision Schedule Rev Date By Description March 24 CH E C K S E T - 0 3 / 2 2 / 2 0 2 4 23 0 1 N T U S T I N A V E , S A N T A AN A , C A , 9 2 7 0 5 TU S T I N & S A N T A CL A R A 76085-018 51969 CHARLIE CHANG AMY YANG MAGED GERGES PLUMBING SITE PLAN PS-100 N 3/32" = 1'-0"1PLUMBING SITE PLAN GENERAL NOTES 1 PLUMBING PLAN KEY NOTES 2 3 A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS. D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS OTHERWISE NOTED. E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2" (10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS. H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS LISTED IN THE PROJECT MANUAL. I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF WATER FILTRATION SYSTEM. J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW TO RENOVATED SYSTEMS. CONTRACTOR SHALL FIELD VERIFY ALL PIPE CONDITIONS PRIOR TO CONSTRUCTION , INCLUDING EXACT LOCATION, AVAILABLE INVERT, DIRECTION OF FLOW, AND CAPACITY FOR THE ADDED FIXTURE LOAD FROM THIS T.I.. SEE P-200 PLUMBING WASTE PLAN FOR CONTINUATION. SEE P-100 PLUMBING WATER PLAN FOR CONTINUATION. INSTALL NEW GREASE INTERCEPTOR.4 1S T P E R M I T S U B M I T T A L S E T - 0 4 / 1 6 / 2 0 2 4 5 PR O J E C T N A M E : PR O J E C T A D D R E S S : TU S T I N & S A N T A CL A R A 23 0 1 N T U S T I N A V E , S U I T E A SA N T A A N A , C A , 9 2 7 0 5 STORE #: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 76085-018 04-15-2024 51969 CHARLIE CHANG SEPIDEH SHARIFI MAGED GERGES 2301 N Tustin Ave #A8/22/2024