HomeMy WebLinkAbout2301 N Tustin Ave Unit #A - Plan1. THE DRAWINGS CONSTITUTE THE CONTRACT DOCUMENTS FOR CONSTRUCTION.
ALL GENERAL REQUIREMENTS ARE TO BE MET AND ALL MATERIALS, FINISHES AND
SYSTEMS ARE TO BE INSTALLED AND PERFORM PER SPECIFICATIONS UNLESS
OTHERWISE NOTED.
2. GENERAL CONTRACTOR SHALL VISIT THE SITE, REVIEW THE BUILDING DRAWINGS
AS SUBMITTED BY STARBUCKS AND BECOME THOROUGHLY FAMILIAR WITH THE
SITE CONDITIONS PRIOR TO CONSTRUCTION.
3. GENERAL CONTRACTOR SHALL CONSULT WITH STARBUCKS CONSTRUCTION
MANAGER TO RESOLVE ANY CHANGES, OMISSIONS OR PLAN DISCREPANCIES
PRIOR TO CONSTRUCTION.
4. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH LOCAL, COUNTY,
STATE AND FEDERAL CODES AND ORDINANCES.
5. GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES.
6. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES
REQUIRED BY OTHER TRADES AND NOTIFY STARBUCKS CONSTRUCTION MANAGER
OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL
DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED
OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. DO
NOT SCALE DRAWINGS.
7. GENERAL CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS, FLOORS,
CEILINGS, OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME
DAMAGED DURING THE COURSE OF THE WORK.
8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING PERMITS FOR FIRE
PROTECTION. PLUMBING, MECHANICAL, AND ELECTRICAL SYSTEMS (IF SEPARATE
FROM BUILDING) PRIOR TO INSTALLATION OF SUCH SYSTEMS.
9. GENERAL CONTRACTOR SHALL RETAIN ONE SET OF PERMIT PLANS ON-SITE TO
DOCUMENT ALL CHANGES MADE DURING CONSTRUCTION. THE RECORD DRAWINGS
SHALL BE ISSUED TO THE OWNER AT PROJECT CLOSE-OUT AS DESCRIBED IN THE
GENERAL REQUIREMENTS OF THE PROJECT MANUAL.
10. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING DELIVERY OF
MATERIALS FROM STARBUCKS CONTRACTED THIRD PARTY LOGISTICS
DISTRIBUTION SERVICES AND VENDOR DIRECT SHIPMENTS. SEE THE PROJECT
MANUAL FOR ADDITIONAL INFORMATION.
11. RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS AND EQUIPMENT IS
IDENTIFIED IN THE DRAWING SCHEDULE SHEETS UNDER THE COLUMN LABELED
"FURNISHED BY/RESPONSIBILITY".
12. FOR THE PURPOSE OF THE DOCUMENTS, TO “INSTALL”, SHALL MEAN TO
PROVIDE ALL FASTENERS, MISCELLANEOUS HARDWARE, BLOCKING, ELECTRICAL
CONNECTIONS, PLUMBING CONNECTIONS AND OTHER ITEMS REQUIRED FOR A
COMPLETE AND OPERATIONAL INSTALLATION, UNLESS OTHERWISE NOTED.
13. ALL ITEM SUBSTITUTIONS MUST BE APPROVED BY THE STARBUCKS CONSTRUCTION
MANAGER.
MAILING
ADDRESS:
DESIGN
MANAGER:
STARBUCKS COFFEE COMPANY
CONTACT: ISCOLINA DELGADO -
CHARLIE CHANG
starbuckspc@hestiaatelier.com
STARBUCKS COFFEE COMPANY
2401 UTAH AVENUE SOUTH
MS STOP: S-SD10
SEATTLE, WASHINGTON 98134
(206) 318-1575
CONSTRUCTION
MANAGER:
STARBUCKS COFFEE COMPANY
CONTACT: MATT ROBITAILLE
mrobitai@starbucks.com
ARCHITECT
OF RECORD:
MEP
CONSULTANT
OF RECORD:
PIVOT ENGINEERING CONSULTANTS
CONTACT: MOSTAFA ZUBAIR
(909) 610-5364
MZUBAIR@PECCUSA.COM
PROJECT
MANAGER:
HESTIA ATELIER, LLP
CONTACT: ISCOLINA DELGADO
(626) 222-7669
starbuckspc@hestiaatelier.com
HESTIA ATELIER, LLP
CONTACT: HIDENORI IWAGAMI
3 PETERS CANYON RD. STE:110
IRVINE, CA 92606
(626) 222-7669
starbuckspc@hestiaatelier.com
PROJECT
SPECIALIST:
STARBUCKS COFFEE COMPANY
MICHELE GURLEY
(714) 477-2850
mgurley@starbucks.com
LEGEND: X - SHEET ISSUED
R - SHEET ISSUED FOR REFERENCE AND COORDINATION ONLY
SEE TITLEBLOCK FOR REVISION ISSUE DATE(S)
SCOPE OF WORK
INTERIOR REMODEL OF EXISTING STARBUCKS COFFEE TENANT IMPROVEMENT.
SCOPE INCLUDES:
- NEW CASEWORK
- NEW NON-LOAD BEARING INTERIOR PARTITIONS
- NEW BEVERAGE PREP EQUIPMENT
- NEW PLUMBING FIXTURES
- NEW FLOOR FINISH
- NEW WALL FINISH
- CEILING MODIFICATIONS
- NEW INTERIOR LIGHTING
- NEW ARTWORK
- NEW INTERIOR FURNITURE
- UPGRADE DRIVE-THRU WAY FINDING SIGNAGE LIKE FOR LIKE (UNDER
SEPARATE PERMIT)
THERE ARE NO CHANGES TO OCCUPANCY TYPE OR TOTAL SQUARE FOOTAGE
OF EXISTING TENANT SPACE.
CODE AUTHORITIES: CITY OF SANTA ANA MUNICPAL CODE
BUILDING CODE: 2022 California Building Code
PLUMBING CODE: 2022 California Plumbing Code
MECHANICAL CODE: 2022 California Mechanical Code
ELECTRICAL CODE: 2022 California Electrical Code
ENERGY CODE:2022 California Energy Code
FIRE CODE:2022 California Fire Code
HEALTH CODE:2022 California Retail Food Code
ACCESSIBILITY CODE: CH 11B OF 2022 CBC
ZONING INFORMATION:
PARCEL NUMBER: 396-141-01, 396 - 141 - 07
LEGAL DISCRIPTION: CHAPMAN TR LOT 5 BLK B E 172 FT W 202 FT S 192 FT -EX STS- TR 175
PERMITTED LAND USE: COMMERCIAL
ZONING:ARTERIAL COMMERCIAL (C5)
CURRENT USE:COFFEE SHOP
SEPARATE SUBMITTALS: - DRIVE-THRU WAY FINDING SIGNAGE
E SANTA CLARA AVE.
N
T
U
S
T
I
N
A
V
E
.
HI
G
H
W
A
Y
5
5
A/C AIR CONDITIONING
ACT ACOUSTICAL CEILING TILE
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AMP AMPERE
ARCH ARCHITECT
BOH BACK OF HOUSE
CAB CABINET
CL CENTER LINE
CLG CEILING
CM STARBUCKS
CONSTRUCTION MANAGER
CTR CENTER
CX COMMISSIONING
CXA COMMISSIONING AGENT
DEG DEGREE
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DM STARBUCKS
DESIGN MANAGER
DN DOWN
EA EACH
EL ELEVATION
EQ EQUAL
EXIST EXISTING
EXT EXTERIOR
FF&E FURNITURE,
FIXTURE, AND EQUIPMENT
FLR FLOOR
FOH FRONT OF HOUSE
FOIC FURNISHED BY OWNER,
INSTALLED BY CONTRACTOR
FOIO FURNISHED BY OWNER
INSTALLED BY OWNER
FT FOOT/FEET
G GROUND
GC GENERAL CONTRACTOR
GWB GYPSUM WALLBOARD
HC HOLLOW CORE
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATING
AND AIR CONDITIONING
I.D. INSIDE DIAMETER
LEED LEADERSHIP IN ENERGY
AND ENVIRONMENTAL DESIGN
LL LANDLORD
LV LOW VOLTAGE
MAX MAXIMUM
MEP "MECHANICAL, ELECTRICAL
AND PLUMBING"
MFR MANUFACTURER
MIN MINIMUM
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NTS NOT TO SCALE
OC ON CENTER
O.D. OUTSIDE DIAMETER
PIR PASSIVE INFRARED SENSOR
PLC PLACE
R RADIUS
REF REFERENCE
REQ‘D REQUIRED
REV REVISION
RND ROUND
SB STARBUCKS
SC SOLID CORE
SF SQUARE FEET
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
TEMP TEMPORARY
TYP TYPICAL
UC UNDER COUNTER
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
X' XX"
X
N
NORTH
ARROW
XXXX AFF
XXXXXW
XX
Scale: X =X
0 2 4 8
GRAPHIC
SCALE
DATUM
POINT
EXTERIOR
ELEVATION
CALL-OUT
INTERIOR
ELEVATION
CALL-OUT
SECTION
CALL-OUT
DETAIL
CALL-OUT
REVISION
TAG
PAINT
TAG
DESIGN ID
TAG
DOOR
TAG
WINDOW
TAG
SHEET
NOTE
CALLOUT
ABOVE FINISH
FLOOR
HEIGHT TAG
FINISH FACE TO
FINISH FACE
DIMENSION
REVISION
CLOUD
X-X-XP
T XXXXX XXXXXX XXXXX D XX
INTERIOR
WALL TAG
RESPONSIBILITY ABBREVIATIONS
SB - SUPPLIED BY STARBUCKS INSTALLED BY GENERAL CONTRACTOR
GC - SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR
CW - SUPPLIED BY CASEWORK VENDOR - INSTALLED BY VENDOR / GENERAL
CONTRACTOR
VD - SUPPLIED BY VENDOR - INSTALLED BY GENERAL CONTRACTOR
OCCUPANCY TYPE:B
TENANT AREA:1,607 S.F.
CONSTRUCTION TYPE:V-B
FIRE SPRINKLER:NO
NUMBER OF STORIES:1
STORAGE SHELVING REQUIRED:
96' LINEAR FEET, MIN. 18" DEEP.
* 3'W X TIERS HIGH
* LOWEST SHELF MIN. 6" FROM FLOOR
* UNITS MOUNTED A MIN. 1" FROM ALL WALL SURFACES.
* MUST MEET ALL REQUIREMENTS OF THE ORANGE COUNTY DEPARTMENT
OF ENVIRONMENTAL HEALTH.
PROVIDED CALCULATIONS:
* 3' LINEAR FEET, MIN. 18" DEEP.
* LENGTH OF SHELVING UNIT X # OF TIERS X # OF UNITS = MIN. 96' OR GREATER
3LF X 5 TIERS UNITS X 11 UNITS = 165 LF > 96 LF (COMPLIES)
SHEET SHEET TITLE B
I
D
S
E
T
P
E
R
M
I
T
S
E
T
R
E
V
I
S
I
O
N
1
R
E
V
I
S
I
O
N
2
R
E
V
I
S
I
O
N
3
R
E
V
I
S
I
O
N
4
GENERAL
G001 GENERAL INFORMATION
G002 COMPOSITE PLAN
G002A ENLARGED COMPOSITE PLAN
G003 LIFE SAFETY AND ACCESSIBILITY PLAN
G004 ACCESSIBILITY DETAILS
G004A ACCESSIBILITY NOTES
G004B ACCESSIBILITY NOTES
DEMOLITION
D001 ARCHITECTURAL DEMO SITE PLAN
D101 DEMOLITION FLOOR PLAN
D102 DEMO REFLECTED CEILING PLAN
ARCHITECTURAL
A001 ARCHITECTURAL SITE PLAN
A002 ARCHITECTURAL SITE ACCESSIBILITY DETAILS
A101 BUILDING FLOOR PLAN
A102 BUILDING FLOOR PENETRATION PLAN
INTERIORS
I101 FF & E PLAN
I102 CASEWORK PLAN
I103 REFLECTED CEILING PLAN
I103A REFLECTED CEILING DIMENSION PLAN
I103B ENLARGED SOFFIT DIMENSION PLAN
I104 FLOOR FINISH PLAN
I105 WALL FINISH PLAN
I201 INTERIOR FINISH ELEVATIONS
I202 INTERIOR FINISH ELEVATIONS
I203 INTERIOR FINISH ELEVATIONS
I204 INTERIOR FINISH ELEVATIONS
I205 INTERIOR FINISH ELEVATIONS
I400 ENLARGED ENGINE PLAN
I401 ENLARGED CASEWORK PLAN
I401A ENLARGED CASEWORK PLAN
I402 ENLARGED RESTROOM ACCESSIBILITY PLAN
I501 INTERIOR DETAILS
I501A INTERIOR DETAILS
I501B INTERIOR DETAILS
I501C INTERIOR DETAILS
I502 CASEWORK DETAILS
I502A CASEWORK DETAILS
I502B CASEWORK DETAILS
I502C CASEWORK DETAILS
I503 FLOOR AND WALL FINISH DETAILS
I504 ELECTRICAL DETAILS
I504A ELECTRICAL DETAILS
I504B ELECTRICAL DETAILS
I504C ELECTRICAL DETAILS
I504D ELECTRICAL DETAILS
I505 PLUMBING DETAILS
I505A PLUMBING DETAILS
I505B PLUMBING DETAILS
I505C PLUMBING DETAILS
I601 CASEWORK AND FF&E SCHEDULES
I602 INTERIOR FINISHES SCHEDULES
ELECTRICAL
E001 ELECTRICAL NOTES
E002 ELECTRICAL SPECIFICATIONS
E200 LIGHTING PLAN
E210 LUTRON ONE-LINE DIAGRAM
E220 LUTRON LOOP LAYOUT
E300 POWER PLAN
E310 ENLARGED ENGINE PLAN
E320 ELECTRICAL DETAILS
E330 ELECTRICAL DETAILS
E500 SINGLE LINE DIAGRAM AND PANEL SCHEDULES
E600 INTERIOR LIGHTING COMPLIANCE CERT
E610 INTERIOR LIGHTING COMPLIANCE CERT
E620 INTERIOR LIGHTING COMPLIANCE CERT
MECHANICAL
M001 MECHANICAL GENERAL NOTES & LEGENDS
M002 MECHANICAL SCHEDULES
M100 MECHANICAL FLOOR PLAN
M200 MECHANICAL ROOF PLAN
M300 MECHANICAL DETAILS
M400 MECHANICAL T-24
MD100 MECHANICAL DEMO FLOOR PLAN
PLUMBING
P001 PLUMBING GENERAL NOTES & LEGENDS
P002 PLUMBING SCHEDULES & CALCULATIONS
P003 PLUMBING SCHEDULES & CALCULATIONS
P100 PLUMBING WATER PLAN
P200 PLUMBING WASTE PLAN
P400 PLUMBING WATER ISOMETRIC
P401 PLUMBING WASTE & VENT ISOMETRIC
P500 PLUMBING DETAILS
P501 PLUMBING DETAILS
P502 PLUMBING DETAILS
P503 PLUMBING DETAILS
P504 PLUMBING DETAILS
PS100 PLUMBING SITE PLAN
NUMBER OF SHEETS: 83
SHEET INDEXSYMBOLS LEGEND GENERAL NOTES ABBREVIATIONS LIST PROJECT CONTACTS
SITE INFORMATION
BUILDING INFORMATION
VICINITY PLAN
STATE OF CALI F RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
A RC H I T EC TU RE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
5
/
2
0
2
4
1
0
:
2
1
:
2
7
A
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\
T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
G001
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
GENERAL INFORMATION
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
RESPONSIBILITY LEGEND
DRY STORAGE REQUIREMENTS
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
A
Bldg# 101119116-17
Elec# 20182680
Plmg# 30147191
APPROVALS:
PLNG - PRaj
BLDG - CSG Consultants
ELEC - CSG Consultants
PLMG - TLuka
2301 N Tustin Ave
#A8/22/2024
(E) RO SYSTEM &
WATER HEATER
(N) MOP SINK
(N) HAND
SINK
(N) QUEUE RAIL
(N) TRASH &
RECYCLE
STATION
G002A
1
I402
3
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E) (E)
(E) 2-DR
REACH-IN
FREEZER
(E) 1-DR
REACH-IN
FREEZER
(E) 2-DR
REACH-IN
FRIDGE
(E) DATA
RACK
ABOVE
(N) METRO
RACK
(N)
(E)
METRO
RACK
(10)
(E) TRASH
BIN
(N) ICE
MACHINE / BIN/
DIVERTER
(E) 2-DR
REACH-IN
FRIDGE
(N) COLD
BREW
STORAGE
/CART
(E) WATER
FILLING
STATION
(E)
SANITIZER
(N)
3-COMP
SINK
(E) MANAGER'S
EQUIPMENT
(N) MANAGER'S
DESK
(N) COAT
HOOK
(N) MIRROR
15
33
3
3
3
3
3
3
3
3
66 CLEARø 3' - 0"
(E) LOCKERS (2)
(N) 1-DR U/C
FRIDGE
(N) MIRCOWAVE
(E) THAW
RACK
(N) 1-DR
REACH-IN
FREEZER
ADJACENT
TENANT
(NIC)
BACKBAR
RETAIL
SEATING
AREA
UNISEX
PARTNER
RESTROOM
UNISEX
CUSTOMER
RESTROOM
PARTNER /
MANAGER
AREA
WORKROOM
(N) MERCH DISPLAY
1
2
2 2
2
2
2
2
4
4
5
5
7
78
9
10
11
11
12
13
14
16
17
17
18
18
19
20
21
22
CLEARø 3' - 0"
1
CLEARø 3' - 0"
CLEARø 3' - 0"(N) EMPLOYEE
BREAK SINK
6
15
13
A. EXISTING ACCESSIBILE TITLE 24 PART 2 (PER 2022 CBC) COMPLIANT PATH OF
TRAVEL TO REMAIN.
B. ACCESSIBILE TITLE 24 PART 2 (PER 2022 CBC) COMPLIANT BATHROOM
FIXTURES TO REMAIN.
C. WHERE TWO EXITS OR EXIT ACCESS DOORWAYS ARE REQUIRED FROM ANY
PORTION OF THE EXIT ACESS, THE EXIT DOORS OR EXIT ACCESS
DOORWAYS SHALL BE PLACED IN A DISTANCE APART EQUAL TO NOT LESS
THAN ONE-HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL
DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED IN A
STRAIGHT LINE BETWEEN EXIT DOORS OR EXIT ACCESS DOORWAYS CBC
1015.2.1.
D. ALL THRESHOLD AND FLOORING MATERIAL TRANSITIONS TO MEET
ACCESSIBILITY REQUIREMENTS ON DETAIL 7 / G-004.
E. ALL DOOR CLEARANCES PER DETAIL 6 / G-004 - U.N.O.
COMPOSITE PLAN GENERAL NOTES
COMPOSITE PLAN KEYNOTES
ACCESSIBILITY KEYNOTES
1 THRESHOLDS TO BE BARRIER FREE COMPLIANT PER ALL
APPLICABLE CODES.
2 BARRIER-FREE PATH OF TRAVEL. PER CBC 11B-403.5.1
3 30" (160 MM) X 48" (1220 MM) CLEAR FOR WHEELCHAIR ACCESS.
4 60" (1525 MM) DIAMETER MINIMUM TURN RADIUS FOR WHEELCHAIR
ACCESS.
5 32" (815 MM) MINIMUM CLEAR AT RESTROOM DOOR.
6 POS TRANSACTION PLANE, TRASH & RECYCLE CART TOP AND
HAND-OFF PLANE ARE 34 INCHES (860 MM) ABOVE THE FINISHED
FLOOR FOR WHEELCHAIR ACCESSIBILITY.
7 PROVIDE BARRIER-FREE SIGNAGE AT ACCESSIBLE RESTROOMS
PER ALL APPLICABLE CODES. REFER TO DETAILS 3 & 11 / SHEET
G004.
8 TACTILE EXIT SIGN PER DETAIL 1/G004
9 INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN WHERE
REQUIRED BY APPLICABLE LAWS OR CODES. SEE 2 / G004. GC TO
PROVIDE IF NOT EXISTING
10 G.C. TO POST SIGN THAT READS "THIS DOOR TO REMAIN UNLOCKED
WHEN THIS SPACE IS OCCUPIED". THE SIGN SHALL BE IN LETTERS 1"
HIGH ON A CONTRASTING BACKGROUND
11 EXISTING EXIT / EMERGENCY LIGHTS ABOVE TO REMAIN.
12 RELOCATED EXISTING FIRE EXTINGUSHER -TYPE 2A10BC PER CFC
906
13 EXTERIOR BARRIER FREE PATH OF TRAVEL -48" MIN
17 ACCESSIBLE RESTROOM -SEE SHEET G004 FOR MOUNTING
HEIGHTS.
18 EXISTING EXIT DOORS TO REMAIN, REFER TO DETAILS 1,2 & 6 /
SHEET G004.
20 EXISTING AIR CURTAIN ABOVE TO REMAIN.
21 NEW LUTRON PANEL ABOVE ELECTRICAL PANELS. REFER TO
ELECTRICAL DRAWINGS FOR MORE INFORMATION
19 EXISTING ELECTRICAL PANELS TO REMAIN.
22 NEW TRASH BIN. TO BE ORDERED BY OPERATIONS IF NEEDED
14 EXISTING DOOR IS EQIPPED WITH SURLOCK HARDWARE TO REMAIN
15 ACCESSIBLE DINING SURFACE AT 28" MIN-34" MAX AFF COMPLYING
WITH SECTIONS CBC 11B-226, 902
16 GC TO POST "NO SMOKING" SIGN THAT PROHIBITS SMOKING WITHIN
25 FT FROM BUILDING ENTRIES PER CALGREEN SEC. 5
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
6
:
2
1
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
G002
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
COMPOSITE PLAN
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
1/4" = 1'-0"1ACCESSIBILITY PLAN
N
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
(E) CUP
LABELER
(E) WARMING
OVEN (2)
(N) DUMP
SINK
(E) GRINDER(N) CLOVER
VERTICA
BREWER
(N) HAND
SINK
(N) PAPER
TOWEL
DISPENSER
(N) 1-DR U/C
FRIDGE
(E) 1-DR U/C
FRIDGE
(E) 1-DR U/C
FRIDGE
(E) 1-DR U/C
FRIDGE
(E) 1-DR U/C
FRIDGE
(E)
WARMING
FRIDGE
(E) 1-DR U/C
FRIDGE
(E) POS
EQUIPMENT
(2)
(E) SAFE
(N) FOOD
CASE
(E) PASTRY CART
(E) CUP
CADDY
(E) CUP
CADDY
(N) COMBO
SINK
(E) ESPRESSO
MACHINE
(N) 45LBS
ICE BIN
(E) CUP
LABELER
(N) COMBO
SINK
(E) ESPRESSO
MACHINE
(N) 45LBS
ICE BIN
(E) AV DIGITAL
PRODUCTION
MANAGER
STARDAND
(N) ORDER
STATUS BOARD
(E) NITRO TAP &
BADGE
(N) NITRO
FRIDGE
(E) NITRO
GENERATOR
(E) BLENDER
(N) PITCHER
RINSER SINK
(E)
BLENDER
(N) HAND
SINK
(N) PAPER
TOWEL
DISPENSER
1 1
(N) COMBI
OVEN
(N)
WARMING
WALL
(E) DT POS
EQUIPMENTS
(N) DT
WINDOW
(N) U/C
PASTRY
TRAY
(E)
WARMING
FRIDGE
(E) CUP
LABELER
(N) REFRESHER
DISPENSE (2)
G002A
4
(N) PASTRY
COOLING
RACK
(N) PASTRY
COOLING
RACK (2)
(E) 1-DR U/C
FRIDGE
(N) DT
WINDOW
SHELF
ENLARGED COMPOSITE PLAN KEYNOTES
1 P.O.S. HANDOFF PLANES & TRASH & RECYCLE COUNTERTOPS ARE
2'-10" A.F.F. FOR WHEELCHAIR ACCESSIBILITY.
A. EXISTING ACCESSIBILE TITLE 24 PART 2 (PER 2022 CBC) COMPLIANT PATH OF
TRAVEL TO REMAIN.
B. ACCESSIBILE TITLE 24 PART 2 (PER 2022 CBC) COMPLIANT BATHROOM
FIXTURES TO REMAIN.
C. WHERE TWO EXITS OR EXIT ACCESS DOORWAYS ARE REQUIRED FROM ANY
PORTION OF THE EXIT ACESS, THE EXIT DOORS OR EXIT ACCESS
DOORWAYS SHALL BE PLACED IN A DISTANCE APART EQUAL TO NOT LESS
THAN ONE-HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL
DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED IN A
STRAIGHT LINE BETWEEN EXIT DOORS OR EXIT ACCESS DOORWAYS CBC
1015.2.1.
D. ALL THRESHOLD AND FLOORING MATERIAL TRANSITIONS TO MEET
ACCESSIBILITY REQUIREMENTS ON DETAIL 7 / G-004.
E. ALL DOOR CLEARANCES PER DETAIL 6 / G-004 - U.N.O.
COMPOSITE PLAN GENERAL NOTES
(N) MILK
DISPENSER
(N) MILK
DISPENSER
(N) MILK
DISPENSER
(N) ICE
DISPENSER
(E) CUP
LABELER
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
5
/
2
0
2
4
1
0
:
2
1
:
3
2
A
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
G002A
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ENLARGED COMPOSITE
PLAN
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
1/2" = 1'-0"11ST FLOOR -ENLARGED COMPOSITE PLAN
N
1/2" = 1'-0"4ENLARGED COMPOSITE UPPER PLAN
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
A
2301 N Tustin Ave
#A8/22/2024
MEANS OF EGRESS NOTES
A. EVERY ROOM OR SPACE THAT IS ASSEMBLY OCCUPANCY SHALL HAVE THE
OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE,
NEAR THE MAIN EXIT ACCESS DOORWAY. POSTED SIGNS SHALL BE OF AN
APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE
OWNER AUTHORIZED AGENT. CBC 1004.9
B. EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS
OR SIMILAR SPACES. CBC 1016.2
C. PANIC AND FIRE EXIT HARDWARE, WHERE INSTALLED ON DOORS IN THIS
BUILDING SHALL SATISFY THE FOLLOWING CBC 1010.1.10:
1) THE ACTUATION PORTION OF THE RELEASING DEVICE SHALL EXTEND AT
LEAST ONE-HALF OF THE DOOR LEAF WIDTH.
2) THE MAXIMUM UNLATCHING FORCE DOES NOT EXCEED 15 POUNDS (6.8 KG).
3) PIVOTED OR BALANCED DOORS SHALL BE OF THE PUSH-PAD TYPE WHERE
PANIC HARDWARE IS REQUIRED AND THE PAD SHALL NOT EXTEND ACROSS
MORE THAN ONE-HALF OF THE DOOR WIDTH, MEASURED FROM THE LATCH
SIDE.
4) PANIC HARDWARE LISTED IN ACCORDANCE WITH UL 305.
5) FIRE EXIT HARDWARE LISTED IN ACCORDANCE WITH UL 10C AND UL 305.
D. STRUCTURAL ELEMENTS, FIXTURES OR FURNISHINGS SHALL NOT PROJECT
HORIZONTALLY FROM EITHER SIDE MORE THAN 4 INCHES (100 MM) OVER ANY
WALKING SURFACE BETWEEN 27 INCHES (685 MM) AND 80 INCHES (2030 MM)
ABOVE THE WALKING SURFACE.
EXCEPTION: HANDRAILS SERVING STAIRS AND RAMPS ARE PERMITTED TO
PROTRUDE 4 1/2 INCHES (115 MM) FROM THE WALL. CBC 1003.3.3
E. THE PATH OF EGRESS TRAVEL EXITS AND WITHIN EXITS IN THIS BUILDING SHALL
BE IDENTIFIED BY EXIT SIGNS CONFORMING TO THE REQUIREMENTS OF CBC
SECTION 1013.1 AND AS NOTED BELOW:
1) EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF EGRESS
TRAVEL.
2) EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE
DIRECTION OF EGRESS TRAVEL.
3) NO POINT IN A CORRIDOR SHALL BE MORE THAN 100 FT (30.5 M) OR THE
LISTED VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS LESS, FROM THE
NEAREST VISIBLE EXIT SIGN.
F. WHERE KEY OPERATED LOCKING DEVICES ARE USED, POST A SIGN ON OR
ADJACENT TO THE REQUIRED MAIN EXIT DOOR WITH 1 INCH (25 MM) LETTERING
STATING THAT "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS
OCCUPIED". CBC 1010.1.9.4
G. EGRESS DOORS OR GATES SHALL BE OPENABLE FROM THE EGRESS SIDE
WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT. DOOR
HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES SHALL BE
INSTALLED 34 INCHES (860 MM) TO 48 INCHES (1220 MM) ABOVE FINISHED
FLOOR. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT
PERMITTED. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE
MORE THAN ONE OPERATION. CBC 1010.1.9
H. LANDINGS SHALL BE PROVIDED ON EACH SIDE OF DOORS AND SUCH LANDING
SHALL BE AT THE SAME ELEVATION ON EACH SIDE OF THE DOOR LANDINGS
SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE DOOR AND LENGTH
MEASURED IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 44 INCHES (11120
MM). CBC 1010.1.5, 1010.1.6
KEYNOTES
1 THRESHOLDS TO BE BARRIER FREE COMPLIANT PER ALL
APPLICABLE CODES.
2 BARRIER-FREE PATH OF TRAVEL -CBC 11B 403.5.1
3 30" (160 MM) X 48" (1220 MM) CLEAR FOR WHEELCHAIR ACCESS.
4 60" (1525 MM) DIAMETER MINIMUM TURN RADIUS FOR WHEELCHAIR
ACCESS.
5 32" (815 MM) MINIMUM CLEAR AT RESTROOM DOOR.
6 POS TRANSACTION PLANE, CONDIMENT CART TOP AND HAND-OFF
PLANE ARE 34 INCHES (860 MM) ABOVE THE FINISHED FLOOR FOR
WHEELCHAIR ACCESSIBILITY.
7 PROVIDE BARRIER-FREE SIGNAGE AT ACCESSIBLE RESTROOMS
PER ALL APPLICABLE CODES. REFER TO DETAILS 3 & 11 / SHEET
G004.
8 TACTILE EXIT SIGN PER DETAIL 1/G004
9 INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN WHERE
REQUIRED BY APPLICABLE LAWS OR CODES. SEE 2 / G004. GC TO
PROVIDE IF NOT EXISTING
10 G.C. TO POST SIGN THAT READS "THIS DOOR TO REMAIN UNLOCKED
WHEN THIS SPACE IS OCCUPIED". THE SIGN SHALL BE IN LETTERS 1"
HIGH ON A CONTRASTING BACKGROUND
11 EXISTING EXIT / EMERGENCY LIGHTS ABOVE TO REMAIN.
12 RELOCATED EXISTING FIRE EXTINGUSHER -TYPE 2A10BC PER CFC
906
13 EXTERIOR BARRIER FREE PATH OF TRAVEL -48" MIN
14 EXISTING DOOR IS EQIPPED WITH SURLOCK HARDWARE TO REMAIN
15 ACCESSIBLE DINING SURFACE AT 28" MIN-34" MAX AFF COMPLYING
WITH SECTIONS CBC 11B-226, 902
LEGEND
TRAVEL DISTANCE
EMERGENCY LIGHT
X'-X" (XXMM)
EMERGENCY EXIT LIGHT/SIGN
FIRE EXTINGUISHER
ADA ACCESSIBLE SEATING
36" (915MM) X 48" (1220MM) CLEAR AREA
LOAD FACTOR:
OCC LOAD:
64 SF
5
SEATING AREA
15
LOAD FACTOR:
OCC LOAD:
350 SF
6
RETAIL
60
LOAD FACTOR:
OCC LOAD:
292 SF
2
BACKBAR
200
LOAD FACTOR:
OCC LOAD:
123 SF
RESTROOMS /
VESTIBULE
0
LOAD FACTOR:
OCC LOAD:
317 SF
2
WORKROOM
200OCCUPANCY LEGEND
BACKBAR
MANAGER / PARTNER REST
AREA
RESTROOMS / VESTIBULE
RETAIL
SEATING AREA
STANDING SPACE
WORKROOM
LOAD FACTOR:
OCC LOAD:
122 SF
1
MANAGER / PARTNER
REST AREA
150
ADJACENT
TENANT
(NIC)
8 911110
14
13
2
3
2
2
2
222
2
2
3
33
15
3
15 3
3
5
5
2
2
11
12
2 2 2 2
2
22
2 2 2 2
2
2
2
2
2
3
3
3
4
4
MOST
REMOTE
POINT
MA
X
T
R
A
V
E
L
D
I
S
T
A
N
C
E
F
R
O
M
MO
S
T
R
E
M
O
T
E
P
O
I
N
T
3
5
'
-
6
"
MAX TRAVEL DISTANCE FROM
MOST REMOTE POINT 68'-3"13
1
66
6
MOST
REMOTE
POINT
7
7
LOAD FACTOR:
OCC LOAD:
39 SF
8
STANDING SPACE
5
SEATING AREA
(BOOTH)
LOAD FACTOR:
OCC LOAD:
49 SF
4
SEATING AREA
15
LOAD FACTOR: 1 PER 24"
22'-0" LF
OCC LOAD: 11
MOST
REMOTE
POINT
TOTAL 12
TOTAL ACCESSIBLE SEATS ( ≥ 5% ) 1
TABLE TOPS AT BANQUETTE 4 8 SEATS 2
TABLE TOP, ROUND 2 4 SEATS 2
DESCRIPTION NUMBER OF ITEMS SEATS PER ITEM
INDOOR SEATING CALCULATIONS
**RETAIL ESTABLISHMENT SERVES WATER UPON REQUEST.
*IN EACH BATHROOM OR TOILET ROOM, URINALS SHALL NOT BE SUBSTITUTED FOR MORE THAN 67% OF THE REQUIRED
WATER CLOSETS IN ASSEMBLY OCCUPANCIES.
PROVIDED 2 M 2 F 2 M 2 F
REQUIRED 1 M 1 F 1 M 1 F
1:1-50 ( MALE ) / 1:1-25 ( FEMALE ) 1:1-150 ( MALE & FEMALE )FIXTURES
WATER CLOSETS LAVATORY
19 OCC. 20 OCC. 39 OCC.OCCUPANCY MALE FEMALE TOTAL
TABLE 422.1 (2022 CPC) / OCCUPANT LOAD CALCULATED PER 1004.5 2022 CBC
PLUMBING FIXTURE CALCULATIONS
MAXIMUM. TRAVEL DISTANCE PROVIDED = 68' - 3"
MAXIMUM. ALLOWABLE TRAVEL DISTANCE = 100' - 0"
NUMBER OF EXITS PROVIDED = 2
NUMBER OF EXITS REQUIRED = 1
EXITS = 72 IN. PRIMARY ENTRY, 36 IN. WORKROOM
EXIT WIDTH PROVIDED = 108 IN.
EXIT WIDTH REQUIRED - 39 OCC. x 0.2 = 7.2 IN.
EGRESS CALCULATIONS
N
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
2
2
/
2
0
2
4
1
2
:
1
1
:
4
8
P
M
C:
\
U
s
e
r
s
\
b
s
a
u
n
\
H
e
s
t
i
a
A
t
e
l
i
e
r
D
r
o
p
b
o
x
\
P
r
o
j
e
c
t
s
\
S
t
a
r
bu
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\
T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
G003
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
LIFE SAFETY AND
ACCESSIBILITY PLAN
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
OCCUPANCY CALCULATION
Name Area LOAD FACTOR
OCCUPANT
LOAD
SEATING AREA 64 SF 15 5
RETAIL 350 SF 60 6
BACKBAR 292 SF 200 2
RESTROOMS / VESTIBULE 123 SF 0
WORKROOM 317 SF 200 2
MANAGER / PARTNER REST
AREA
122 SF 150 1
STANDING SPACE 39 SF 5 8
SEATING AREA Not Placed 15
SEATING AREA 49 SF 15 4
GRAND TOTAL 28
1/4" = 1'-0"1EGRESS/OCCUPANCY PLAN
(BOOTH)22 ' -0" LF 1 PER 24"11
39
0
A
A
A
A
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
2301 N Tustin Ave
#A8/22/2024
WOMEN
INDICATES MINIMUM
CLEAR SPACE AT
DOOR
DOOR STRIKE
SWING SIDE OF
DOOR BUILDING WALL
DOOR / DOOR SWING
MINIMUM REQUIRED DOOR CLEARANCE
STOREFRONT, INTERIOR OR EXTERIOR DOOR - A LEVEL AND CLEAR FLOOR OR
LANDING ON EACH SIDE OF DOOR SHALL BE PROVIDED. THE LEVEL AREA SHALL
HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60" AND THE
LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 48" AT DOORS WITH
AUTOMATIC CLOSURES AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE
DOOR IN THE CLOSED POSITION
1' - 0"
4'
-
0
"
1' - 6" CLR. @ INTERIOR DOORS
2' - 0" CLR. @ EXTERIOR DOORS
4' - 0"
5'
-
0
"
5' - 0"
LEVER HANDLE
NOTE:
CBC SECTION 11B-703
ANSI A117.1, 703.3.10, 703.4.5
ROOM IDENTIFICATION
SIGNAGE SEE 11/-
TO
B
O
T
T
O
M
O
F
C
H
A
R
A
C
T
E
R
60
"
M
A
X
.
BO
T
T
O
M
O
F
B
R
A
I
L
L
E
48
"
M
I
N
.
-
6
0
"
M
A
X
.
HEIGHT OF TACTILE SIGNS AND BRAILLE:
TYPICAL AT EXITS AND RESTROOMS
34
"
M
I
N
.
T
O
4
4
"
M
A
X
.
58
"
M
I
N
.
T
O
6
0
"
M
A
X
.
A
.
F
.
F
.
MAX.
9"
TEXT: 5/8" MIN. - 2" MAX.
PARTIAL SIGNAGE SECTION AND MOUNTING SPECIFICATIONS
FACE OF TOILET ROOM DOOR
CENTER OF
SIGNAGE
IDENTIFYING SIGNAGE
TOILET ROOM IDENTIFYING SIGNAGE
DOUBLE STICK MOUNTING FOAM
58
"
-
6
0
"
A
.
F
.
F
.
1/4" THICK ACRYLIC PLASTIC-
IMAGE AND LETTERS SHALL BE
ENGRAVED (MIN. 1/32" DIST.)
INTO PLAQUE SURFACE.
SYMBOLS AND LETTERS SHALL
BE DIFFERENT FROM THE
DOOR IN COLOR AND
CONTRAST.
SUBSURFACE IMAGES SHALL
BE CENTERED ON PLAQUE.
UNISEX
WOMEN
MEN
1' - 0"
1' - 0"
1' - 0"
LIGHT SWITCH
THERMOSTAT
SEAT COVER &
TISSUE DISPENSER
AND / OR NAPKIN
DISPOSAL
GRAB BAR
PROTRUSION 14"
MIN. OUTWARD INSULATE HOT WATER &
DRAIN PIPES
OPERATING
DEVICE HEIGHT
MIRROR - 40" MAX. TO BOTTOM
EDGE OF REFLECING SURFACE
SOAP
DISPENSER
PAPER TOWEL
DISPENSER
44
"
M
A
X
.
40
"
MA
X
.
33
"
-
3
6
"
19
"
M
A
X
.
17
"
M
I
N
.
1'
-
5
"
M
A
X
.
R
I
M
H
E
I
G
H
T
LAVATORYURINAL
WATER CLOSET
SIDE
WATER CLOSET
FRONT
MA
X
.
34
"
MI
N
.
27
"
OUTLET OVER
COUNTER
OUTLET
BO
T
.
F
I
X
T
.
15
"
M
I
N
.
T.
O
.
F
I
X
T
.
48
"
M
A
X
.
ELECTRICAL
18" MAX.
17" MIN.
MIN.
1' - 0"
MIN.
2' - 0"
7"-9"
MI
N
.
1
1
/
2
"
HARDWARE / EFFORT
CBC 11B-404.2.7 / 11B-404.2.9
TYPE OF HARDWARE: PUSH / PULL
HARDWARE MUST BE CENTERED BETWEEN 34"
AND 44" A.F.F.
MAX. EFFORT FOR INT. / EXT. DOOR - 5 LBS.
SMOOTH SURFACE PER
CBC SECTION 11B- 404.2.10
10" KICKPLATE OR SMOOTH SURFACE FULL
WIDTH OF DOOR
THRESHOLDS
CBC SECTION 11B-404.2.5
1/2" HIGH MAX. THRESHOLD
1/4" PER FOOT MAX. SLOPE
DOOR SIZE
CBC SECTION CBC 11B-404.2.3
3'-0" WIDE
6'-8" HEIGHT
32" CLEAR WIDTH
90 DEGREE DOOR OPENING
EXTERIORINTERIOR
CL
1/
2
"
M
A
X
.
10
"
M
I
N
.
34" TO 44" A.F.F.
MAX.
0'-0" FIN. FLR.
LETTERS - 5/8" MIN. - 2"
MAX. - 1/32" RAISED
TEXT AND ASSOCIATED BRAILLE SHALL READ AS INDICATED IN THE DRAWING AND
PER CBC SECTTION 1011 & ANSI 117.1, 703.3.10, 703.4.5
EXIT 3"
M
I
N
.
. .. .. ... . . . ...
BRAILLE PER CBC
11B-703.3.2
5'
-
0
"
(
6
0
"
)
M
A
X
.
FIN. FLR.
4'
-
0
"
(
4
8
"
)
M
I
N
.
EXIT EXIT... .. ... ... .. ...
THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO
IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY
DISABLED PERSONS.
THE SYMBOL SPECIFIED ABOVE SHALL CONSIST OF A WHITE FIGURE ON A BLUE
BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN FEDERAL
STANDARD 595B.
6"
6"
1/8 " STEEL BACKING
PLATE - WELD TO (3) STUDS
MINIMUM
METAL SPACER
INTERIOR FINISH - SEE
ELARGED TOILET PLAN AND
FINISH SCHEDULE
1 1/2 " O.D.
GRAB BAR
(N
.
T
.
S
.
)
33
"
M
I
N
.
T
O
3
6
"
M
A
X
FIN. FLR.
1 1/2"
TOP OF GRIPPING
SURFACE
CLEAR KNEE SPACE
WALL MOUNTED LAVATORY
19 " MAX
17" MIN.
34
"
M
A
X
.
29
"
M
I
N
.
9"
M
I
N
.
6" MAX.
8" MIN.
KNEE CLEARANCE
OF
R
E
F
L
E
C
T
I
V
E
S
U
R
F
A
C
E
40
"
M
A
X
.
T
O
B
O
T
T
O
M
INSULATION AROUND PIPE
27
"
M
I
N
.
11" MIN.
(30" MIN.)
2' - 6"
(4
8
"
M
I
N
.
)
4'
-
0
"
(1
9
"
M
I
N
.
)
1'
-
7
"
TABLE TOP @ +34" A.F.F.
(28" MIN. - 34" MAX.)
30" X 48" CLEAR
FLOOR SPACE
2'
-
3
"
M
I
N
6'
-
8
"
M
I
N
4" MAX
1'
-
3
"
M
I
N
4'
-
0
"
M
A
X
4'
-
0
"
M
A
X
1' - 8" MAX
3'
-
8
"
M
A
X
>20"-25" MAX
3'
-
1
0
"
M
A
X
2'
-
1
0
"
M
A
X
>10"-24" MAX
2'
-
1
0
"
M
A
X
0' - 10" MAX
4'
-
0
"
M
A
X
1'
-
3
"
M
I
N
4'
-
0
"
M
A
X
0' - 10" MAX
42"MINIMUM
33
"
-
3
6
"
M
A
X
.
24" MIN.
33
"
-
3
6
"
M
A
X
.
36" MIN.
12"
MAX.
TO TOP OF GRAB BAR
17" MIN. / 18" MAX. TO
CENTERLINE OF WATER
CLOSET
REINFORCEMENT
BACKING - TYP. - SEE
DETAIL 5 / SHEET G-003
GRAB BAR LENGTH
PROVIDE 1-1/2" MIN.
BETWEEN TOP OF TANK
AND BOTTOM OF GRAB BAR
12"
MIN
.
24"
MIN
.
1/4" = 1'-0"6MINIMUM DOOR CLEARANCE
1/2" = 1'-0"3ACCESSIBLE RESTROOM SIGNAGE1" = 1'-0"11RESTROOM IDENTIFYING SIGNS
1/4" = 1'-0"4ACCESSIBLITY FOR ACCESSORIES - STANDARD MOUNTING HEIGHTS
12" = 1'-0"7ENTRANCE DOOR ADA DETAIL
12" = 1'-0"1TACTILE EXIT SIGN
3" = 1'-0"2INTERNATIONAL ACCESSIBILITY SYMBOL
6" = 1'-0"5TOILET GRAB BAR13/4" = 1'-0"9KNEE SPACE AT LAVATORY
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
6
:
3
2
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
G004
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ACCESSIBILITY DETAILS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
3/4" = 1'-0"13KNEE SPACE AT TABLE1/2" = 1'-0"17UNOBSTRUCTED PATH OF TRAVEL
3/4" = 1'-0"18UNOBSTRUCTED FORWARD REACH
3/4" = 1'-0"15OBSTRUCTED HIGH FORWARD REACH
3/4" = 1'-0"16OBSTRUCTED SIDE REACH
3/4" = 1'-0"14UNOBSTRUCTED SIDE REACH 12" = 1'-0"8GRAB BAR REINFORCEMENT
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
6
:
3
3
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
G004A
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ACCESSIBILITY NOTES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
AUTOMATIC DOORS
1. AUTOMATIC DOORS SHALL COMPLY WITH C.B.C.SECTION 11B-404.3
2. FULL-POWERED AUTOMATIC DOORS SHALL COMPLY WITH ANSI/BHMA
A156.10. LOW -ENERGY AND POWER ASSISTED DOORS SHALL COMPLY
WITH ANSI/BHMA A156.19
3. THE MIMINUM CLEAR WIDTH FOR AUTOMATIC DOOR SYSTEMS IN A
DOORWAY SHALL PROVIDE A CLEAR UNOBSTRUCTED OPENING OF 32
INCHES MINIMUM WITH ONE LEAF POSITIONED AT AN ANGLE OF 90
DEGREES FROM ITS CLOSED POSITION.
4. CLEARANCES AT POWER ASSISTED DOORS AND AUTOMATIC DOORS
SERVING AN ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH C.B.C.
11B-404.2.4
5. THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS WITH AUTOMATIC
DOORS SHALL COMPLY WITH CBC 11B-404.2.5
6. MANUALLY OPERATED ACTUATOR CONTROLS FOR AUTOMATIC DOORS
SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT
GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED
TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM.
7. THE CLEAR FLOOR SPACE ADJACENT TO THE CONTROL SHALL BE
LOCATED BEYOND THE ARC OF THE DOOR SWING AND SHALL COMPLY
WITH C.B.C. 11B-305
8. AUTOMATIC DOOR OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR
MORE OF THE REACH RANGES SPECIFIED IN C.B.C. 11B-308
9. WHERE DOORS AND GATES WITHOUT STANDBY POWER ARE PART OF A
MEANS OF EGRESS, THE CLEAR BREAK OUT OPENING AT SWINGING OR
SLIDING DOORS AND GATES SHALL BE 32 INCHES MINIMUM WHEN
OPERATED IN EMERGENCY MODE, UNLESS MANUAL SWINGING DOORS
AND GATES COMPLY WITH C.B.C 11B-404.2 AND SERVE THE SAME MEANS
OF EGRESS.
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
6
:
3
5
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
G004B
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ACCESSIBILITY NOTES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
A. GENERAL CONTRACTOR TO VERIFY ALL EXISTING ELEVATIONS AND BUILDING
CONDITIONS IN FIELD PRIOR TO START OF CONSTRUCTION.
B. PROVIDE DETECTABLE WARNING (IF APPLICABLE PER LOCAL CODE) AT
TRANSITION FROM SIDEWALK TO DRIVE AISLE.
C. ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL HAVE SURFACE
SLOPE NOT TO EXCEED 2% IN ALL DIRECTIONS.
D. REFER TO ELECTRICAL DRAWINGS FOR SITE RELATED ELECTRICAL WORK.
(WHEN APPLICABLE)
E. EXISTING SITE FEATURES TO REMAIN, NO CHANGE U.N.O
GENERAL NOTES
SITE PLAN KEYNOTES
1 NEW GREASE INTERCEPTOR. REFER TO PLUMBING DRAWINGS FOR
MORE INFORMATION
3 NEW DT DIRECTIONAL EXIT/THANK YOU SIGN. MOUNT TO EXISTING
FOOTING
4 NEW DT CLEARANCE BAR. (UNDER SEPARATE PERMIT)
2 NEW DT DIRECTIONAL ARROW SIGN. MOUNT TO EXISTING FOOTING
7 RESTRIPE EXISTING ACCESSIBLE PARKING. REFER TO 7/A002 FOR
MORE INFORMATION
8 EXISTING PARKING STALL TO REMAIN.
9 EXISTING MOP (MOBILE-ORDER-PAY) DEDICATED PARKING STALL TO
REMAIN
10 EXISTING DIGITAL ORDER SCREEN TO REMAIN.
11 EXISTING TRASH ENCLOSURE TO REMAIN. EXISTING DEDICATED
AREA FOR RECYCLING.
19 NEW WAYFINDING PAVEMENT GRAPHICS.
16 RESTRIPE EXISTING FADED ACCESSIBLE PATH CROSSWALK. REFER
TO 1/ A002
12 STARBUCKS, AREA OF WORK.
13 EXISTING PATIO AREA TO REMAIN. NO EXTERIOR SEATING IS BEING
PROPOSED.
14 EXISTING LANDSCAPED AREA TO REMAIN
15 EXISTING PUBLIC RIGHT OF WAY
18 EXISTING NON-ILLUMINATED BOLLARD TO REMAIN.
17 EXISTING DT 5-PANEL MENU BOARD TO REMAIN.
5 EXISTING ACCESSIBLE PATH OF TRAVEL FROM/TO ACCESSIBLE
PARKING
6 EXISTING ACCESSIBLE PATH OF TRAVEL FROM/TO PUBLIC RIGHT OF
WAY
20 NEW INTERNATIONAL SYMBOL FOR ACCESSIBLE PARKING -REFER
TO 2/A002
21 EXISTING ACCESSIBLE PARKING SIGNAGE TO REMAIN PER DETAIL
5/A002
22 EXISTING DRIVE-THRU LANE TO REMAIN.
23 EXISTING ADJACENT TENANT. (NIC)
24 EXISTING DETECTABLE WARNINGS TO REMAIN. REFER TO 4/A002
25 EXISTING ACCESSIBLE PATH SIGN TO REMAIN. REFER TO DETAIL
6/A002.
26 EXISTING TOWAWAY SIGN TO REMAIN PER DETAIL 8/A002.
EXISTING LANDSCAPE AREA
LEGEND
EXISTING 6" (150MM) CONCRETE CURB
ACCESSIBLE UNOBSTRUCTED PATH OF TRAVEL 48" MIN WIDTH
(UNLESS NOTED OTHERWISE) WITH SLOPE NOT TO EXCEED 5% IN
DIRECTION OF TRAVEL AND CROSS SLOPE NOT TO EXCEED 2%
N
T
U
S
T
I
N
A
V
E
.
E SANTA CLARA AVE.
1 2 3 4
5
6
7
8
Y 23113
S 22544
S 23077
S 23071
Y 23115
S 23077
Y 23117
Y 23117
Y 23117
Y 23117
Y 23117
Y 23117
ADJACENT
TENANT
(NIS)
1
2
4
2
3
5
5
6
78 8
88
6
9
10
11
12
13
14141414
14
14
14
14
1414
15
15
15
15 15 15
16
17
18
19
19
19
19
19
19
19
19
20
21
22
22
23
24
24
24
25
P 21669
P X21676
26
26
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
6
:
5
6
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
A001
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ARCHITECTURAL SITE
PLAN
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
N
3/32" = 1'-0"1ARCHITECTURAL SITE PLAN
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
6'
-
8
"
A
.
F
.
F
.
+3
6
"
W
A
L
L
M
O
U
N
T
E
D
TEXT SHALL NOT BE LESS
THAN 1 INCH IN HEIGHT
NOTE:
1. CONTRACTOR SHALL VERIFY THE ADDRESS AND PHONE NUMBER
INDICATED ON SIGN PRIOR TO THE PRINTING OF SIGNS.
2. THE ADDRESS AND PHONE NUMBER SHALL BE IMPRINTED ON THE
SIGN BY THE SIGN COMPANY.
3. THIS SIGN SHALL BE PLACED AT THE ENTRANCE TO OFF-STREET
PARKING FACILITIES.
THE NAME, ADDRESS AND PHONE
NUMBER SHALL BE IMPRINTED ON
THE SIGN BY THE SIGN COMPANY
UNAUTHORIZED VEHICLES
PARKED IN DESIGNATED
ACCESSIBLE SPACES NOT
DISPLAYING
DISTINGUISHING
PLACARDS OR SPECIAL
LICENSE PLATES ISSUED
FOR PERSONS WITH
DISABILITIES WILL BE
TOWED AWAY AT THE
OWNER'S EXPENSE.
TOWED VEHICLES MAY BE
RECLAIMED AT
(---ADDRESS---)
OR BY TELEPHONING
(XXX) XXX-XXXX
17" MIN.
2' - 0"
22
"
M
I
N
.
2'
-
7
"
FINISH SURFACE OR GRADE
REFLECTIONIZED PORCELIAN
ENAMELED STEEL SIGN WITH
BEADED LETTERS OR EQUAL BOLTED
TO 2" SQ. BRONZE POWDER COATED
POST WITH (2) 3/8" DIA. BOLTS - SIGN
TO DISPLAY INTERNATIONAL SYMBOL
OF ACCESIBILITY AND HAVE A
DIRECTIONAL ARROW INDICATING
THE ACCESSIBLE PATH-OF-TRAVEL
10"
1'
-
0
"
5'
-
0
"
N
.
T
.
S
.
0.90"
AT
BASE
0.45"
AT TOP
0.
2
0
H
T
.
TYPICAL PLAN
TYPICAL SECTION A
A
-
NOTE:
1. DETECTABLE WARNING SURFACES SHALL BE YELLOW CONFORMING TO FS 33538
OF FEDERAL STANDARD 595C." (CBC, Sec. 11B-705.1.1.3). MATERIAL SHALL BE
INTEGRAL PART OF THE WALKING SURFACE.
2. DETECTABLE WARNING SURFACES SHALL CONTRAST VISUALLY WITH ADJACENT
WALKING SURFACES EITHER LIGHT-ON-DARK OR DARK-ON-LIGHT. THE MATERIAL
USED TO PROVIDE CONTRAST SHALL BE AN INTEGRAL PART OF THE SURFACE."
(CBC, SEC. 11B-705.1.1.3).
3. ONLY APPROVED DSA-AC DETECTABLE WARNING PRODUCTS AND DIRECTIONAL
SURFACES SHALL BE INSTALLED AS PROVIDED IN THE CALIFORNIA CODE OF
REGULATIONS (CCR), TITLE 24, PART 1, CHAPTER 5, ARTICLE 2, 3 AND 4." (CBC,
SEC. 11B-705.3).
2.
3
5
"
2.35"
ADDITIONAL SIGN REQUIRED
AT
VAN ACCESSIBLE SPACES
WHITE TEXT ON BLUE
REFLECTIVE BACKGROUND
1/4" WIDE BORDER LINE AT
ALL SIDES
WHITE OCCUPANT ON DARK
BLUE BACKGROUND
METAL SIGN WITH ROUNDED
CORNERS CORNERS
3" HIGH TEXT - 1/2" WIDE STROKE
2" HIGH TEXT - 3/8" WIDE STROKE
1. ALL PARKING SPACE SIGNS, IN CALIFORNIA, CONSTRUCTED ON OR AFTER JULY
1, 2008, SHALL INCLUDE THE VERBAGE "$250 MINIMUM FINE". CALIFORNIA
VEHICLE CODE SECTION 22511.8 (AB1511), CBC 11B-502.6.2
2. 70 SQ. INCH MINIMUM ACCESSIBLE SIGN PER CBC 11B-502.6
MATCH CENTER SPECIFICATION
FOR SIGNAGE CONSTRUCTION
AND MATERIALS
1' - 0"
60
"
W
A
L
L
M
O
U
N
T
E
D
6'
-
8
"
M
I
N
.
P
O
L
E
M
O
U
N
T
E
D
2'
-
0
"
60
"
W
A
L
L
M
O
U
N
T
E
D
6'
-
8
"
M
I
N
.
WH
E
R
E
O
C
C
U
R
S
ACCESSIBLE ROUTE CROSSWALK
STRIPING. 4" WIDE PAINTED BLUE
STRIPES, OVER YELLOW HIGHWAY
PAINT (2 COATS) WITH DIAGONAL
STRIPING AT 3'-0" O.C.
NOTE:
ALL SLOPE CONDITIONS SHALL COMPLY
WITH ACCESSIBLE ROUTE CRITERIA PER
STATE OF CALIFORNIA TITLE 24.
3' -
0
"
5' - 0"
WHITE PAINTED BORDER AND
SYMBOL OVER BLUE
BACKGROUND (COLOR NO. 15090
IN FEDERAL STANDARD 595a)
4" TYP.3' - 0"4" TYP.
3'
-
0
"
18
'
-
0
"
T
O
T
A
L
S
T
A
L
L
L
E
N
G
T
H
3'-0"
O.C.
NOTE:
REFER TO CIVIL DWGS FOR FURTHER INFORMATION.
SLOPE IN STALL & LOADING ZONE NOT TO EXCEED 2% IN ANY DIRECTION
NO PARKING
SL
O
P
E
1/
4
"
P
E
R
FT
.
M
A
X
.
SLOPE
1/4" PER
FT. MAX.
INTERNATIONAL SYMBOL
OF ACCESSIBILITY-REFER
TO 2/A002
4" WIDE STRIPED LOADING
ZONE-12" HIGH LETTERS
READING "NO-PARKING"
SHALL BE PAINTED WITHIN
THE LOADING ZONE AREA-
PAINT COLOR: WHITE
EXISTING CONC. CURB
ACCESSIBLE CURB RAMP
SEE DETAIL 3/A002
PRE-CAST CONCRETE
WHEEL
9' - 0" MIN
9' - 0"
9' - 0" MIN
8' - 0"
VAN ACC.
0"C.F.
6"C.F.
0"C.F.
6"C.F.
2%
2%
2%
8.3%
8.3%
CROSS SLOPE OF
LANDING AREAS DO
NOT EXCEED 2% IN
ANY DIRECTION
NOTE: SURFACE WILL
REQUIRE 36" SECTION OF
TRUNCATED DOMES IF FLAT
TRAVEL SURFACE ADJOINS
VEHICULAR TRAFFIC WAY
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
6
:
5
7
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
A002
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ARCHITECTURAL SITE
ACCESSIBILITY DETAILS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
Revision Schedule
Rev Date By Description
1" = 1'-0"8SITE ACCESSIBILITY SIGNAGE
1" = 1'-0"6ACCESSIBLE PATH SIGN
3" = 1'-0"4TRUNCATED DOMES
3/4" = 1'-0"5ACCESSIBLE PARKING SIGN 1/4" = 1'-0"1H.C. ACCESS ROUTE
3/4" = 1'-0"2ACCESSIBLE SYMBOL
NOT USEDNOT USEDNOT USED
NOT USEDNOT USEDNOT USED
NOT USEDNOT USEDNOT USED
NOT USEDNOT USEDNOT USED
1/8" = 1'-0"7VAN ACCESSIBLE PARKING 1/8" = 1'-0"3EXISTING CURB RAMP DETAIL
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
KEYNOTES GENERAL NOTES
A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY STARBUCKS
CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION.
ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT.
B. GENERAL CONTRACTOR TO PROVIDE FIRE TREATED WOOD STUD BLOCKING,
OR EQUIVALENT TO SUPPORT ANY WALL ATTACHMENT AND/OR SIGNAGE.
C. IF EXISTING EXTERIOR ENTRANCE THRESHOLD EXCEEDS MINIMUM BARRIER
FREE PROVISION OF THE CODE, REMOVE AND REPLACE WITH ACCESSIBLE
THRESHOLD. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES AT
ACCESSIBLE DOORWAYS TO BE BEVELED WITH A SLOPE NO GREATER THAN
1:12.
D. ALL DIMENSIONS ARE TO FACE OF STUD UNLESS SHOWN OR NOTED
OTHERWISE.
E. GENERAL CONTRACTOR TO PROVIDE WATER RESISTANT TYPE 'X' GYP. BD. AT
RESTROOM AND BACKBAR WALLS (ALL WET WALLS).
F. ALL DOORS SHALL BE 32” (815MM) MINIMUM CLEAR OPENING WHEN OPENED TO
90 DEGREE POSITION UNLESS OTHERWISE NOTED.
G. SEE SHEET A601 OR I601 FOR EXTERIOR DOOR AND WINDOW SCHEDULES.
H. STARBUCKS VENDOR TO PROVIDE DOOR HARDWARE COMPONENTS AND GC
TO INSTALL.
I. VERIFY ALL EXISTING DOORS, HARDWARE AND FRAMES MEET STARBUCKS
AND/OR CODE REQUIREMENTS.
J. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM THE
CITY.
K. SEE STRUCTURAL FOR KNEE WALL BRACING IF APPLICABLE.
L. SEE SHEET A501 FOR BUILDING DETAILS IF APPLICABLE.
M. REFER TO SHEET I104 FOR FLOOR FINISHES.
N. PATCH AND REPAIR WALLS AS NECESSARY TO PROVIDE A FINISH READY
SURFACE.
3 G.C. TO PROVIDE AND INSTALL 6" CONCRETE CURB AT SAFE -CURB
NOT TO EXCEED FOOTPRINT OF SAFE.
1 PROVIDE ADEQUATE REINFORCEMENT AND / OR BLOCKING AS
REQUIRED TO SUPPORT WALL ATTACHMENTS -REFER TO WALL
BLOCKING KEY.
6 EXISTING ELECTRICAL PANELS TO REMAIN.
7 DIMENSION CONTROL DATUM POINT.
11 NEW RESTROOM DOOR. FINISH PER ELEVATIONS
9 ELECTRICAL PANEL LOCATIONS. MAINTAIN MINIMUM CLEARANCE
AS REQUIRED BY CODE.
8 OUTLINE OF BAR PER CASEWORK MANUFACTURER.
10 ALIGN FACE OF FINISHED WALL.
12 NEW TRAFFIC SWINGING DOOR. NO LATCH OR LOCK PROVIDED
13 EXISTING ENTRY/EXIT DOOR TO REMAIN.
14 NEW DRIVE-THRU WINDOW. REFER TO SHEET I602 FOR MORE
INFORMATION.
15 EXISTING EXIT ONLY DOOR TO REMAIN.
2 G.C. TO PROVIDE AND INSTALL 6" CONCRETE CURB AT FOOD CASE -
CURB NOT TO EXCEED FOOTPRINT OF CASE.
4 G.C. TO PROVIDE AND INSTALL 10" CONCRETE CURB AT MOP SINK
RO SYSTEM.
5 EXISTING STOREFRONT TO REMAIN.
GENERAL LEGEND
NEW FULL HEIGHT WALL
EXISTING WALL
WALL BLOCKING CALL-OUT
-
X WALL TYPE TAG
WALL BLOCKING KEY
SYMBOL ITEM
128 LBS
(58 KG)
WEIGHT
36" TO 40"
HEIGHT
A.F.F.
30" (760MM) BEHIND SINK
APPROX. WIDTH
SHELVES ABOVE
COMPARTMENT
SINK
200 LBS
(91 KG)48" TO 76"
96" (2440MM) CENTERED
ABOVE COMPARTMENT SINK
SHELVES AT
MANAGER'S DESK
300 LBS
(136 KG)32" TO 96"
48" (1220MM) 3/4 (19MM) ACX
PLYWOOD, CENTERED ON
SHELVES
DATA RACK 300 LBS
(136 KG)44" TO 96"
BLOCKING PER DETAIL 1/I502B
30" TO 36"60" (1525MM) AROUND WATER
CLOSET
200 LBS
(91 KG)
COMMERCIAL INSTALLATION
REQUIRES CONCEALED ARM CARRIER.
REFER TO MFR'S SPECIFICATION.
200 LBS
(91 KG)
COORDINATE LOCATION AND EXTENT
WITH PENTAIR
TBD BY
VENDOR
WORKROOM
HAND SINK
PASTRY COOLING
RACK
RESTROOM
GRAB BARS
RESTROOM
HAND SINK
REFRESHER
RACKS
UPPER CBE
CABINETRY
WATER
FILTRATION
SYSTEM
A
B
C
D
E
F
G
H
I
J
K
L
M
BLOCKING PER DETAIL 1/I504BDIGITAL MENU
BOARDSN
UPPER PARTNER
REST CABINETRY
ORDER STATUS
BOARD
128 LBS
(58 KG)
BLOCKING PER DETAIL 1/I502B200 LBS
(91 KG)
200 LBS
(91 KG)
28" (710MM) 3/4 (19MM) ACX
PLYWOOD, CENTERED ON RACK
66" TO 120"BLOCKING PER CASEWORK
SPECIFICATIONS
100 LBS BLOCKING PER DETAIL 13/I504B
GC TO PROVIDE BLOCKING PER
MANUFACTURER'S WRITTEN REQUIREMENTS
EMPLOYEE'S
LOCKERS
300 LBS
(136 KG)
TBD BY
VENDOR
45" TO
63 1/2"1' - 1 5/8" (343MM) - PER SHELF
BLOCKING SPECIFICATION TO BE PROVIDED BY VENDORICE DIVERTERO
P MERCHANDISE
DISPLAY
BLOCKING PER DETAIL 3/I502C
1 NEW FULL HEIGHT WALL
3 5/8" X 20 GA. METAL STUDS @16" O.C.
WITH 5/8" TYPE "X" GYP. BD. ON BOTH
SIDES TO 6" ABOVE CEILING - USE
WATER RESISTANT GYP. BD. ON WET
WALLS - DRYWALL SCREWS @ 12" O.C.
9,13
SEE WALL STUD TABLE SHEET I501
WALL TYPES
I501
NEW FURRED FULL HEIGHT WALL
3 5/8" X 20 GA. METAL STUDS @ 16" O.C.
WITH 5/8" TYPE "X" GYP. BD. ON ONE
SIDE TO 6" ABOVE CEILING - USE WATER
RESISTANT GYP. BD. ON ALL WET
WALLS - DRYWALL SCREWS @ 12" O.C.
3
FINISH MAY OCCUR-
SEE WALL FINISH PLAN
& INTERIOR
ELEVATIONS - TYP.
NEW PLUMBING WALL
6" X 20 GA. METAL STUDS @ 16" O.C.
WITH 5/8" TYPE "X" GYP. BD. ON BOTH
SIDES TO 6" ABOVE CEILING - USE
WATER RESISTANT GYP. BD. ON ALL WET
WALLS - DRYWALL SCREWS @ 12" O.C.
2
9,13
I501
9,13
I501
NEW FURRED PLUMBING WALL
6" X 20 GA. METAL STUDS @ 16" O.C.
WITH 5/8" TYPE "X" GYP. BD. ON ONE
SIDE TO 6" ABOVE CEILING - USE WATER
RESISTANT GYP. BD. ON ALL WET
WALLS - DRYWALL SCREWS @ 12" O.C.
NEW FURRED FULL HEIGHT WALL
3 5/8" X 20 GA. METAL STUDS @ 16" O.C.
WITH 5/8" TYPE "X" GYP. BD. ON ONE
SIDE TO 6" ABOVE CEILING - USE WATER
RESISTANT GYP. BD. ON ALL WET
WALLS - DRYWALL SCREWS @ 12" O.C.
5
16,19
I501
4 I501
EXISTING WALL
EXISTING WALL
16,19
ADJACENT
TENANT
(NIC)
HO
L
D
10
'
-
7
3
/
4
"
12
'
-
7
1
/
4
"
6'
-
7
"
15
'
-
7
"
15
'
-
1
1
/
4
"
3 3/4"
1' - 11 1/4"6' - 8 1/2"
14' - 10 3/4"
16' - 7"
22' - 9 1/2"
35' - 1 3/4"
36' - 2 1/2"
20
'
-
1
1
1
/
2
"
21
'
-
7
1
/
2
"
BACKBAR
WORKROOM
SEATING
AREA
RETAIL
UNISEX
CUSTOMER
RESTROOM
UNISEX
PARTNER
RESTROOM
PARTNER /
MANAGER
AREA
D 10086 08
D 10190 09
D 10190 16
A
B
B
C
C
D
E
F
G
G
G
G
H
H
I
J
K
L
M
N
O
(F.O.F)
11' - 7 1/2"
(F.O.F)
5' - 10 1/4"
5' - 6 1/4"3' - 5 1/2"
1' - 10"11' - 5 3/4"
7'
-
4
1
/
4
"
2'
-
4
"
7'
-
6
1
/
4
"
2'
-
1
1
"
11 1/4"3' - 0"3' - 6 1/2"
CLR (F.O.F)
7' - 5 3/4"
CL
R
(
F
.
O
.
F
)
8'
-
1
"
3' - 0"
36" MIN CLR
F.O.F
3' - 0 3/4"3' - 0 3/4"
(F.O.F)
6' - 4 1/4"
36" MIN CLR
(F.O.F)
3' - 0 3/4"
(F.O.F)
2' - 11 3/4"
(F.O.F)
1' - 0 3/4"
1
1
11
1
12
2
2
2
2
2
3
3
3
3
3
3
3
5
3
2
4
3
5
1
1
1
1
1
23
4
5
5
6
7
7
8
8 8
8
9
ALIGN
10
ALIGN
10
11
11
12
13
14
15WX21987
P
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
6
:
5
7
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
A101
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
BUILDING FLOOR PLAN
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
N
1/4" = 1'-0"2FLOOR PLAN
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
A. ALL STUB-UP DIMENSIONS ARE RELATIVE TO FINISHED WALL LOCATIONS
(SHOWN AS OUTLINES ON THIS PLAN). REFER TO FLOOR PLAN FOR WALL
PLACEMENT.
B. FLOOR SINK: REFER TO CUT SHEETS FOR COMPONENT SPECIFICATIONS AND
CUTOUT REQUIREMENTS.
C. WASTE LINE PENETRATIONS: REFER TO PLUMBING PLANS FOR INDIVIDUAL LINE
LOCATIONS.
D. STUB-UP PENETRATIONS: REFER TO ELECTRICAL AND PLUMBING PLANS FOR
INDIVIDUAL STUB-UP LOCATIONS.
E. TOILET FLOOR PENETRATION: REFER TO CUT SHEETS FOR STUB-UP LOCATION
RELATIVE TO FINISHED WALL (IF APPLICABLE).
F. PENETRATION TO BE LOCATED ON CENTERLINE OF WALL OR AS REQUIRED
PER CONDITIONS.
G. TRENCHING OUTLINE FOR GUIDELINE USE ONLY. GENERAL CONTRACTOR TO
COORDINATE WITH SPECIFIC TRADES AND SITE CONDITIONS TO DETERMINE
ACTUAL LAYOUT.
H. REFER TO SHEET I104 FOR FLOOR FINISHES.
KEYNOTES
GENERAL NOTES
1 NEW FLOOR SINK -SEE DETAIL 2 / SHEET A102
2 DATUM CONTROL POINT.
3 NEW WATER CLOSET DRAIN.
5 DEMOLISH EXISTING FLOOR SINK (8)
6 ELECTRICAL STUB-UP LOCATION. SEE ELECTRICAL SHEETS.
7 PLUMBING STUB-UP LOCATION. SEE PLUMBING SHEETS
9 NEW MOP SINK DRAIN.
8 ROUTE SANITIZER DRAIN TO THE NEAREST SANITARY FLOOR SINK.
REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION
4 NEW FLOOR DRAIN CENTERED WITHIN RESTROOM
10 PROVIDE POWER AT NEW BANGUETTE SEATING.
11 PROVIDE POWER FOR DOOR ACTUATOR PUSH PLATE BOLLARD.
LEGEND
EXISTING WALL
DATUM POINT
FLOOR DRAIN
FLOOR SINK
STUB-UP
FLOOR SINK HALF GRATE
FLUSH WITH FLOOR FINISH
GRAVEL BACKFILL
NO-HUB
CONNECTION
3" TAIL PIECE
CONC INFILL AND
TRENCH FOR
BELOW GRADE
UTILITIES
STAINLESS STEEL
FLOOR SINK
W/CLAMPING
FEATURE
1
EQ
EQ
3"
EQ EQ
1' - 9"
DIMENSION
DATUM POINT
ALL CONDUIT
STUB-UPS TO
BE WITHIN THIS
BOUNDARY
2 3 3 3 3
3
1
/
2
"
ESPRESSO BAR DIEWALL
1 3/4" LAN CONDUIT
2 3/4" LAN CONDUIT TO MANAGER'S WORKSTATION
3 3/4" ISOLATED GROUND POWER CONDUIT
ESPRESSO BAR ELECTRICAL STUB-UP KEY
NOTE: SEE SHEET A102 - BUILDING FLOOR PENETRATION
PLAN FOR FINAL DIMENSIONED LOCATION.
DIMENSION
DATUM POINT
ALL CONDUIT
STUB-UPS TO
BE WITHIN THIS
BOUNDARY
1 3/4" POWER CONDUIT TO ELECTRICAL PANEL
2 1/2" PHONE TO MANAGER'S DESK
3 1/2" DATA CONDUIT TO MANAGER'S DESK
POS ELECTRICAL STUB-UP KEY
4 1/2" SECURITY TO MANAGER'S DESK
5 3/4" LAN CONDUIT TO POS/SAFE
6 3/4" POWER CONDUIT FOR PASTRY CASE
POS DIEWALL
EQ
EQ
3"
EQ EQ
1' - 6"
7"1 2 5 634
NOTE: SEE SHEET A102 - BUILDING FLOOR PENETRATION
PLAN FOR FINAL DIMENSIONED LOCATION.
EQ EQ
7"
EQ
EQ
3"
DIMENSION
DATUM POINT
ALL CONDUIT
STUB-UPS TO
BE WITHIN THIS
BOUNDARY
1 CWF STUB-UP
2 CW STUB-UP
ESPRESSO BAR PLUMBING STUB-UP KEY
1 2
POS DIEWALL
NOTE: SEE SHEET A102 - BUILDING
FLOOR PENETRATION PLAN FOR
FINAL DIMENSIONED LOCATION.
3
3
/
4
"
2" CLR
(N) TRENCH(E) SLAB (E) SLAB
2
1
1
1 #4 EPOXY DOWEL A8 18" O.C. W/9" EMBEDMENT. DOWELS MAY
BE STAGGARD ON EACH SIDE OF TRENCG NOT TO EXCEED
18" O.C. ON EACH SIDE. USE SIMPSON SET-XP EPOXY
2 COUNTINIOUS #4 @ 18" O.C (1) #4 MIN. AT TRENCHES 24" OR
LESS IN WIDTH
ADJACENT
TENANT
(NIC)
BACKBAR
RETAIL
SEATING
AREA
WORKROOM
PARTNER /
MANAGER
AREA
UNISEX
PARTNER
RESTROOM
UNISEX
CUSTOMER
RESTROOM
10
5 5
5
5
5
5
5
5
1
P X10726
P X10726 1
P X10726 (3)
1
1
1
1
1
2'
-
1
0
3
/
4
"
17
'
-
1
1
"
6' - 3"
6' - 1"12' - 2 3/4"
1
10' - 8 3/4"
11' - 10"
16' - 0 1/2"
2'
-
6
1
/
4
"
16
'
-
5
"
22
'
-
3
3
/
4
"
1'
-
2
"
9
1' - 1 1/2"
1'
-
6
"
1' - 1 3/4"
1'
-
6
"
3
3
4
4
8
2
2
A102
5
A102
4
A102
6
7 6 6
13
'
-
2
1
/
2
"
1' - 0"
(4)
7' - 0"19' - 10 3/4"
24
5
3
/
4
"
24
2
1
/
2
"
8' - 3 1/4"3' - 10"
20' - 6 3/4"
P 10594
P 10594
11
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
6
:
5
9
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
A102
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
BUILDING FLOOR
PENETRATION PLAN
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
3" = 1'-0"2ECO-GRIP CLAMPING FLOOR SINK DETAIL
G.C. RESPONSIBLE TO VERIFY EXISTING SLAB
CONDITIONS PRIOR TO ANY SAWCUT OR TRENCH WORK.
ALL DIMENSIONS ARE TO FINISH FACE OF WALLS AND/OR
CENTER OF FLOOR SINK AND ELECTRICAL STUB-OUTS
G.C. TO X-RAY (E) FLOOR SLAB WHEN PROJECT IS NOT
SLAB ON GRADE.
G.C. TO COORDINATE ANY CONFLICT W/ STARBUCKS
C.M., ARCHITECT, AND ENGINEERS.
1 1/2" = 1'-0"4ELECTRICAL STUB-UPS AT ESPRESSO BAR1 1/2" = 1'-0"5ELECTRICAL STUB-UPS AT POS1 1/2" = 1'-0"6PLUMBING STUB-UPS AT ESPRESSO BAR 1 1/2" = 1'-0"3CONCRETE POUR BACK DETAIL
N
1/4" = 1'-0"1FLOOR PENETRATION PLAN
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
EXISTING LANDSCAPE AREA
LEGEND
EXISTING 6" (150MM) CONCRETE CURB
ACCESSIBLE UNOBSTRUCTED PATH OF TRAVEL 48" MIN WIDTH
(UNLESS NOTED OTHERWISE) WITH SLOPE NOT TO EXCEED 5% IN
DIRECTION OF TRAVEL AND CROSS SLOPE NOT TO EXCEED 2%
N
T
U
S
T
I
N
A
V
E
.
E SANTA CLARA AVE.
1 2 3 4
5
6
7
8
ADJACENT
TENANT
(NIS)
1
2
2
4
3
5
5
6
6
15
15
15
15 15
78 8
88
9
10
17
18
11
12
13
14141414
14
14
14
14
1414
16
19
19
19
19
19
19
19
19
21
20
22
22
23
24
24
24
25
GENERAL NOTES
A. GENERAL CONTRACTOR TO VERIFY ALL EXISTING ELEVATIONS AND BUILDING
CONDITIONS IN FIELD PRIOR TO START OF CONSTRUCTION.
B. ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL HAVE SURFACE
SLOPE NOT TO EXCEED 2% IN ALL DIRECTIONS.
C. REFER TO ELECTRICAL DRAWINGS FOR SITE RELATED ELECTRICAL WORK.
SITE PLAN KEYNOTES
1 EXISTING GREASE INTERCEPTOR TO REMAIN. NIS
3 DEMO EXISTING DT DIRECTIONAL EXIT/THANK YOU SIGN. KEEP
EXISTING FOOTING TO MOUNT NEW SIGN TO IT.
4 DEMO EXISTING DT CLEARANCE BAR. KEEP EXISTING FOOTING TO
MOUNT NEW SIGN TO IT.
2 DEMO EXISTING DT DIRECTIONAL ARROW SIGN. KEEP EXISTING
FOOTING TO MOUNT NEW SIGN TO IT.
7 RE-STRIPE EXISTING ACCESSIBLE PARKING.
8 EXISTING PARKING STALL TO REMAIN.
9 EXISTING MOP (MOBILE-ORDER-PAY) DEDICATED PARKING STALL TO
REMAIN
10 EXISTING DIGITAL ORDER SCREEN TO REMAIN.
11 EXISTING TRASH ENCLOSURE TO REMAIN. EXISTING DEDICATED
AREA FOR RECYCLING.
19 DEMO EXISTING WAYFINDING PAVEMENT GRAPHICS.
16 RE-STRIPE EXISTING FADED ACCESSIBLE PATH CROSSWALK.
12 STARBUCKS, AREA OF WORK.
13 EXISTING PATIO AREA TO REMAIN.
14 EXISTING LANDSCAPED AREA TO REMAIN
15 EXISTING PUBLIC RIGHT OF WAY
18 EXISTING NON-ILLUMINATED BOLLARD TO REMAIN.
17 EXISTING DT 5-PANEL MENU BOARD TO REMAIN.
5 EXISTING ACCESSIBLE PATH OF TRAVEL FROM/TO ACCESSIBLE
PARKING
6 EXISTING ACCESSIBLE PATH OF TRAVEL FROM/TO PUBLIC RIGHT OF
WAY
20 RE-STRIPE INTERNATIONAL SYMBOL FOR ACCESSIBLE PARKING.
21 EXISTING ACCESSIBLE PARKING SIGNAGE TO REMAIN PER DETAIL
5/A002
22 EXISTING DRIVE-THRU LANE TO REMAIN.
23 EXISTING ADJACENT TENANT. (NIC)
24 EXISTING DETECTABLE WARNINGS TO REMAIN. REFER TO 4/A002
25 EXISTING ACCESSIBLE PATH SIGN TO REMAIN.
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
6
:
4
3
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
D001
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ARCHITECTURAL DEMO
SITE PLAN
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
N
Revision Schedule
Rev Date By Description
3/32" = 1'-0"1ARCHITECTURAL SITE PLAN
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
A. IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE
INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT,
GENERAL CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER
IMMEDIATELY.
B. GENERAL CONTRACTOR IS RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO
DEMOLITION TO REVEAL FULL SCOPE OF WORK. NOTIFY STARBUCKS
CONSTRUCTION MANAGER IF EXISTING CONDITIONS DEVIATE FROM
CONSTRUCTION DOCUMENTS.
C. REMOVE EXISTING INTERIOR WALL FINISH AS SHOWN. PATCH, REPAIR AND
PREP. SUBSTRATE TO RECEIVE NEW FINISH. REMOVE WALL COVERINGS ON
EXISTING WALLS TO REMAIN THAT FACE AREAS OF DEMOLITION. REMOVAL
SHALL INCLUDE ANY RESIDUAL MATERIAL AFTER DEMOLITION, (I.E. PIECES OF
WALL COVERING OR BACKING). REMOVAL OF ALL COVERINGS IS TO BE DONE
W/O DAMAGING THE EXISTING WALL SURFACE TO REMAIN. ALSO REMOVE WALL
DEVICES AND ITEMS MOUNTED TO WALLS.
D. REMOVE EXISTING FLOORING AS SHOWN. PATCH, REPAIR AND PREP.
SUBSTRATE TO RECEIVE NEW FINISH. REMOVAL OF EXISTING FLOORING
INCLUDES, BUT IS NOT LIMITED TO REMOVAL OF EXISTING CERAMIC TILE,
CARPET OR VINYL TILE FLOORING AND ASSOCIATED WALL BASE. SUBFLOOR TO
BE STRIPPED OF ALL COVERING/FINISH AND CLEANED TO REMOVE EXISTING
ADHESIVE, GROUT, MORTAR, DIRT AND COATINGS. FINAL SURFACE TO BE
STREAK-FREE WITH NO MACHINE MARKS AND/OR SMOOTH, STABLE AND LEVEL.
PROVIDE LEVELING WHERE NECESSARY TO ACCOMMODATE NEW FINISHES.
E. DEMOLITION PLANS REPRESENT APPROXIMATE LOCATION OF EXISTING WALLS
TO BE DEMOLISHED. FIELD VERIFY TYPE OF CONSTRUCTION AND HEIGHT OF
WALLS. PLANS DO NOT NECESSARILY INDICATE ALL DEMO WALLS, COUNTERS,
HANDRAILS, WALL PROTECTION, CLOSETS, SINKS ETC. PRIOR TO DEMOLITION,
FIELD VERIFY THAT WALLS TO BE REMOVED DO NOT PROVIDE SUPPORT FOR
EXISTING BUILDING ELEMENTS AND EXISTING CONSTRUCTION TO REMAIN.
NOTIFY STARBUCKS CONSTRUCTION MANAGER IF DEMOLITION WALLS SUPPORT
EXISTING BUILDING ELEMENTS.
F. DEMOLISH AND REMOVE DOORS, VINYL BASE, CONDUIT, WIRING, DUPLEXES,
DATA OUTLETS, CABLES, SHELVING, METAL STUD AND GYPSUM BOARD WALLS,
CLOSETS, CABINETS, FILES, COUNTERS, WOOD MOLDING, SHELVES AND
ENCLOSURES WHERE APPLICABLE.
G. VERIFY WITH STARBUCKS CONSTRUCTION MANAGER ACCESS TO THE
DEMOLITION AREA, INGRESS AND EGRESS ROUTES FOR MATERIAL AND
EQUIPMENT.
H. PROTECT EXISTING FLOORS, WALLS AND CORNERS TO REMAIN ALONG WORK
ACCESS ROUTES.
I. CONTAIN DUST AND DEBRIS WITHIN THE DEMOLITION AREA.
J. THE GENERAL CONTRACTOR SHALL PERFORM WORK IN A MANNER THAT DOES
NOT DAMAGE THE EXISTING STRUCTURE. DEMOLITION SHALL NOT
COMPROMISE THE STRUCTURAL INTEGRITY OF ANY WALLS, FLOORS, CEILINGS,
SUPPORTS, STRUCTURE, ETC. TO REMAIN.
K. ALL DEMOLITION MATERIALS AND DEBRIS SHALL BE DISPOSED OF ACCORDING
TO FEDERAL, STATE AND LOCAL REGULATIONS.
L. AT LOCATIONS WHERE EXISTING WALLS ARE TO BE REMOVED NEAR EXISTING
WALLS TO REMAIN, PERFORM DEMOLITION WITHOUT DISTURBING EXISTING
ELEMENTS TO REMAIN. WALLS TO REMAIN SHALL BE INTACT AND HAVE A NEAT
SURFACE.
M. REFER TO "ITEMS TO BE PRESERVED" LIST FOR ITEMS THAT SHALL BE
SALVAGED FOR RELOCATION. VERIFY WITH OWNER FOR ON SITE STORAGE
LOCATION OF SALVAGED ITEMS.
N. DAMAGED FIREPROOFING SHALL BE REPAIRED/ REPLACED TO MATCH EXISTING.
O. THE GENERAL CONTRACTOR SHALL DEMOLISH ANY EXISTING ABANDONED
VOICE/DATA CABLING AND DEAD OR NON-USE ELECTRICAL BACK TO PANEL.
ALL RECEPTACLES NOT REUSED ARE TO BE REMOVED, PATCHED AND PAINTED.
P. REMOVAL OF LOW VOLTAGE EQUIPMENT, PERTAINING TO
DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED BY THE
STARBUCKS CONSTRUCTION MANAGER PRIOR TO REMOVAL. SALVAGED
EQUIPMENT SHALL BE STORED IN A CLIMATE CONTROLLED ENVIRONMENT FOR
FUTURE INSTALLATION.
Q. LABEL ALL ITEMS AND PROPERLY STORE FOR RE-INSTALL.
R. REMOVE EXISTING PLUMBING FIXTURES AND HVAC EQUIPMENT AS NECESSARY.
CAP LINES AND TERMINATE DUCTS AS NECESSARY FOR THOSE NOT BEING RE-
USED.
KEYNOTES GENERAL NOTES
15 DEMO EXISTING FRONTLINE AND BACKLINE -COUNTERTOPS AND
CABINETS. SALVAGE ALL COUNTERTOP EQUIPMENT AND 1DR
UNDERCOUNTER FRIDGES -U.N.O.
3 EXISTING STOREFRONT TO REMAIN. WINDOWS ARE FIXED AND NOT
OPERABLE.
7 DEMOLISH EXISTING FLOOR FINISH, ARTWORK AND WALL FINISH AT
CAFE AREA
6 DEMOLISHED EXISTING MERCH BASKETS
5 DEMOLISHED EXISTING NON-LOAD BEARING WALL
8 DEMOLISH EXISTING CONDIMENT CART
17 DEMOLISH EXISTING BACKBAR WALL TILE, MENUBOARDS, UPPER
CUBBIES, VALANCE AND TASK LIGHTING
9 DEMOLISH EXISTING MERCH BAY
16 DEMOLISH EXISTING FLOOR TILE AND BASE AT BACKBAR AND
WORKROOM AREAS
10 DEMOLISH EXISTING FLOOR TILE / BASE AT CAFE AND VESTIBULE
AREA.
11 DEMOLISH EXISTING WALK-OFF MAT
12 DEMOLISH EXISTING INTERIOR FURNITURE THROUGHOUT
13 DEMOLISH EXISTING RESTROOMS AND ALL ASSOCIATED FIXTURES.
18 DEMOLISH EXISTING FLOOR SINK BELOW (8)
1 EXISTING ENTRY/EXIT DOOR TO REMAIN.
4 DEMOLISHED EXISTING BACKBAR TRAFFIC DOOR
2 DEMOLISHED EXISTING DRIVE-THRU WINDOW AND SHELF.
14 EXISTING ELECTRICAL PANEL TO REMAIN
19 DEMOLISH EXISTING LIGHTING CONTROL PANEL
20 EXISTING TEMPERATURE SENSOR TO BE RELOCATED.
21 EXISTING HVAC T-STATS TO BE RELOCATED. (3)
LEGEND
EXISTING ITEM TO REMAIN
ITEM TO BE DEMOLISHED
NON-LOAD BEARING WALLS TO BE DEMOLISHED
EXISTING ITEM TO BE RELOCATED
EXISTING ITEMS TO PRESERVE AND RELOCATE
A BLENDERS (2)
B ESPRESSO MACHINES (2)
C SAFE
Q WATER FILLING STATION
K WARMING OVEN (2)
T 2-DR REACH IN FRIDGE (2)
S 2-DR REACH IN FREEZER
D WARMING U/C FRIDGE (2)
P MANAGER'S STATION EQUIPMENT
R 1-DR REACH IN FREEZER
E 1-DR U/C FRIDGE (5)
M DRIVE-THRU POS EQUIPMENT
L POS EQUIPMENT, PRINTER, & PHONE
H NITRO TAP / NITRO GENERATOR
G CUP LABELER (4)
F GRINDER
V THAW RACK
U SANITIZER
W R.O. SYSTEM & WATER HEATER
X TRASH BIN
I NOT USED
J CUP CADDY (2)
N PASTRY CART
O AV DIGITAL PRODUCTION MANAGER Y METRO RACKS (10)
Z ICE BIN
A1 HAND DRYER (2)
B1 DATA RACK
C1 LOCKERS (2)
CAFE
7 10
BACKBAR
15 16
WORKROOM
16
VESTIBULE
10
UNISEX
RESTROOM 1
UNISEX
RESTROOM 2
13
13
ADJACENT
TENANT
(NIC)
1
1
3 3
3
2 3
3
12
17
8
9
6
6
11
18 18
18
18
1818
18
18
4A
E E
E
E E
D
K K
GF
H
M
G
GB B
L
O
N
CJJ
PW
U
R
S
T
T
X
V
Q
Y Y
Y Y
Y Y
Y
Y
Y
Y
5 5 5
5
5
5
5
55
55
5
RETAIL
7 10
14
Z
D
B1
A1
A1
C1
19
20
20
21
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
6
:
4
8
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
D101
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
DEMOLITION FLOOR
PLAN
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
N
1/4" = 1'-0"1DEMOLITION PLAN
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
GENERAL NOTES
A. IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE
INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GENERAL
CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY.
B. REMOVE EXTRANEOUS EQUIPMENT AS NECESSARY.
C. EXISTING SPRINKLERS TO REMAIN OPERATIONAL DURING CONSTRUCTION.
D. DEMOLISH AND REMOVE SUSPENDED ACOUSTIC LAY-IN, SPLINE OR GYPSUM/
PLASTER CEILING INCLUSIVE OF HANGERS AND CARRYING CHANNELS, WIRES,
CABLES, CONDUIT, ADHERED CEILING TILES, FLEX CONDUIT, ELECTRICAL BOXES,
SMOKE DETECTORS, LIGHT FIXTURES AND WIRING, DUCT WORK, PIPING AND
SUPPORT HANGERS. CUT HANGERS FLUSH. SPACES RECEIVING WALL DEMOLITION
WILL ALSO HAVE CEILING DEMOLITION UNLESS OTHERWISE NOTED.
E. REMOVAL OF LOW VOLTAGE EQUIPMENT, PERTAINING TO DATA/
COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED BY STARBUCKS
CONSTRUCTION MANAGER PRIOR TO REMOVAL. SALVAGED EQUIPMENT SHALL BE
STORED IN A CLIMATE CONTROLLED ENVIRONMENT FOR FUTURE INSTALLATION.
KEYNOTES
8 DEMOLISH EXISTING UPPER SHELF AND ALL ASSOCIATED LIGHTING
& MENU BOARDS
1 OPEN TO STRUCTURE ABOVE.
2 REMOVE ALL EXISTING LIGHTING, WIRING, CONTROLS AND
FASTENERS BACK TO ELECTRICAL PANEL
3 REMOVE EXISTING SECURITY CAMERAS, LOW VOLTAGE CABLING
AND ASSOCIATED CONDUITS. CAMERAS SHALL BE SALVAGED FOR
FUTURE REUSE
7 EXISTING RESTROOM EXHAUST FAN DIFFUSER TO BE RELOCATED
9 EXISTING ELECTRICAL PANELS TO REMAIN
4 EXISTING EMERGENCY EXIT LIGHT/SIGN TO REMAIN
5 EXISTING AIR CURTAIN ABOVE TO REMAIN
6 DEMOLISH EXISTING DUCTWORK AT CAFE AREA. PROVIDE NEW
DESTRIBUTION PER MECHANICAL DRAWINGS
10 DEMOLISH EXISTING WALL MOUNTED SPEAKER (3)
11 EXISTING OCCUPANCY SENSOR TO BE RELOCATED (4)
12 DEMOLISH EXISTING LIGHTING CONTROL PANEL
13 DEMOLISH EXISTING MOP SIGN.
14 EXISTING HVAC SUPPLY DIFFUSER TO BE RELOCATED.
15 EXISTING HVAC RETURN DIFFUSER TO BE RELOCATED.
16 DEMOLISH EXISTING HVAC SUPPLY DIFFUSER
17 DEMOLISH EXISTING 2X4 ACT AT WORKROOM
18 DEMOLISH EXISTING SOFFIT AT BACKBAR
19 DEMOLISH EXISTING RESTROOM AND VESTIBULE GYP. BD CEILING
LEGEND
ITEM TO BE DEMOLISHED
NON-LOAD BEARING WALL TO BE DEMOLISHED
GWB CEILING TO BE DEMOLISHED
EXISTING ITEM TO REMAIN
2X4 ACT TO BE DEMOLISHED
EXISTING ITEM TO BE RELOCATED
ADJACENT
TENANT
(NIC)
RETAIL
2 3
SEATING
AREA
32
BACKBAR
2 3
WORKROOM
2
VESTIBULE
2
UNISEX
RESTROOM 1
2
UNISEX
RESTROOM 2
2
1
1
3
4
5
6
6
8
8
9
11
11
11
11 10
10
10
14
14
14
15
4
13
1414
15
12
16 16
16
16
716 7
16
17
18
19
19
19
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
6
:
5
1
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
D102
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
DEMO REFLECTED
CEILING PLAN
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
N
1/4" = 1'-0"1DEMOLITION REFLECTED CEILING PLAN
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
KEYNOTES GENERAL NOTES
1 ACCESSIBLE 30" X 48" CLEAR SPACE FOR WHEELCHAIR
2 EXISTING ELECTRICAL PANEL TO REMAIN
5 CLEAR SPACE AT ELECTRICAL PANELS.
9 WASTE & RECYCLE STATION. SEE INTERIOR FINISH ELEVATIONS.
11 NEW ORDER STATUS BOARD. PROVIDE POWER AND DATA.
12 EXISTING SAFE LOCATED AT NEW POS CABINET. SEE ELECTRICAL
FOR ADDITIONAL INFORMATION.
13 HAND SINK W/ INTEGRAL SPLASH GUARD.
14 ACCESSIBLE 60" DIA. CLEAR SPACE FOR WHEELCHAIR
6 INSTALL NEW INTERIOR FURNITURE THROUGHOUT AS SHOWN.
4 RELOCTED EXISTING FIRE EXTINGUSHER -TYPE 2A10BC PER CFC
906
15 PROVIDE POWER FOR NEW AUTOMATIC DOOR ACTUATOR, PUSH
PLATE & HARDWARE KEY SWITCH
16 EXISTING & NEW METRO RACKS TOP SHELF NOT TO EXCEED 5'-9"
AFF.
17 MANAGERS DESK. SEE MANAGER'S DESK/EQUIPMENT RACK
ELECTRICAL DETAIL FOR ADDITIONAL INFORMATION.
18 NEW TRASH BIN, ORDER BY FACILITY IF NECESSARY.
A. THE SITE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM
UNLESS OTHERWISE NOTED.
B. ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION
FOUNDATION STANDARDS OR EQUIVALENT.
C. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS,
EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR
ACCUMULATION OF DUST, DIRT AND DEBRIS.
D. EACH HAND WASHING SINK WILL HAVE A SINGLE SERVICE TOWEL AND SOAP
DISPENSER, AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR
PREMIXING FAUCET.
E. SEE SHEET I601 FOR SCHEDULES.
F. SEE WALL FINISH PLAN FOR LOCATION, TAGGING AND FINISH SCHEDULES OF
APPLIED WALL TREATMENT.
G. NO VEGETABLE OR FOOD PREPARATION ON THE PREMISES.
H. NON-MOVABLE EQUIPMENT ON THE FLOOR SHALL BE MOUNTED ON 6" LEGS,
CASTERS OR MANUFACTURER SUPPLIED SKIDS.
I. ALL EQUIPMENT, CONSTRUCTION, AND INSTALLATION SHALL MEET ANSI
CERTIFICATION. ALL PLUMBING, GAS LINES AND CONDUITS, ETC., ARE TO BE
CONCEALED WHERE POSSIBLE. OTHERWISE, THEY MUST BE A MINIMUM OF
SIX INCHES OFF THE FLOOR AND NOT RUN ACROSS AISLE SPACE AND TO BE
INSTALLED AT LEAST 1/2" AWAY FROM THE WALL TO FACILITATE CLEANING.
ALL EQUIPMENT AND BACKSPLASHES ARE TO BE ADEQUATELY SEALED TO
THE WALL. DISPLAYS OF UNPACKAGED FOOD ARE TO BE PROTECTED WITH
SNEEZE GUARDS. ALL EXPOSED SURFACES OF SHELVING, CABINETS AND
UNDERCOUNTERS ARE TO BE SMOOTH AND SEALED.
J. G.C. TO CAULK WHERE COUNTERTOPS MEET FOOD CASE (SEAL WITH THE
DEPARTMENT OF ENVIRONMENTAL HEALTH APPROVED CAULKING) IF
APPLICABLE PER SCOPE.
K. CAULK AND SEAL ALL SEAMS BETWEEN SS COUNTERTOPS USING DOW
CORNING BRAND '732 MULTI PURPOSE SEALANT'.
L. ALL FOOD STORAGE SHALL BE 6" (150mm) A.F.F.
M. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETS) SHALL BE
SEALED.
N. ALL EQUIPMENT AND CABINETRY WILL BE FLUSH MOUNTED TO COUNTERS,
WALLS OR FLOORS, OR BE RAISED TO ALLOW FOR CLEANING.
O. CONFIRM ALL NECESSARY EQUIPMENT CLEARANCES PER PRODUCT CUT
SHEET (E.G. ICE MACHINE).
P. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING DESIGN PLAN. FOR
DATA DEVICE SCHEDULE, REFER TO THE ELECTRICAL DESIGN PLAN.
Q. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM
THE LOCAL JURISDICTION.
19 RELOCATED EXISTING WATER HEATER. MAKE: AO SMITH, MODEL:
DRE-52 100, SOURCE OF POWER: ELECTRIC, KW/H:18
3 NEW LUTRON LIGHTING CONTROL PANEL ABOVE. SEE ELECTRICAL
DRAWINGS FOR MORE INFORMATION
21 RELOCATED EXISTING OCCUPANCY SENSOR (4)
7 NEW MERCHANDISE DISPLAY
22 RELOCATED EXISTING TEMPERTURE SENSOR (2)
20 PROVIDE (2) CONVENIENCE OUTLETS FOR PARTNER USE WITH
USB-A / USB-C PORTS
10 DO NOT BLOCK FOOD CASE INTAKE/EXHAUST.
8 RELOCATED EXISTING HVAC T-STATS (3)
23 PROVIDE MIN. 6" SST SIDE SPLASH GUARD AT 3-COMP SINK. GUARD
TO EXTEND FULL DEPTH OF THE SINK. PROVIDED BY CASEWORK
VENDOR
24 PARTNER RECOGNITION BOARD. SEE INTERIOR ELEVATION.
25 PROVIDE CONVENIECE RECEPTACLE AT PARTNER REST AREA
I400
1
ADJACENT
TENANT
(NIC)
(ABOVE)
1 1
1
1
1
1
1
F 21456
F 21842
F 21449
(4)F 23062(2)
(5)
(5)
F 21800
F 18468
C 23964
E 23526
E 23182
E 23423
E 10416
P 10995
P 10922
E 10698
P 23355
(ABOVE)
X
Y Y
Y
Y
Y
Y
Y
Y
Y
Y
V
T T
R
S
Q
U
P
W
E 22212
E 10416
E 10462
P 14688
P 13588
E 10947
E 10977
E 13578
E 10222
P 13700
P 10447
P 10804
E 13620
E 10267
E 23454
P 10549
P 10152
F 23062
F 21474
(2)
F TK0051FTK0050
E 10462
P 10116
P 21352
E 11115
F 10093
E 10099
E 10859
E 10172
P 11871
E 10862
P 10116
E 11115
P 21352
F 10093
P 11871
E 10099
E 10172
E 10859
E 10862
25
7
14
14
1
1
4
BACKBAR
RETAIL
SEATING
AREA
WORKROOM
PARTNER /
MANAGER
AREA
UNISEX
PARTNER
RESTROOM
UNISEX
CUSTOMER
RESTROOM
6
10
9
11
12
13
13
16
16
16
16
17
18
20
21
21
21
C 20369
B1
A1
A1
F TK0076
FTK0053
F TK0078
F TK0077
F TK0079
Z
C1
19
D 23131D23130
D 23129
3
15
D 23135
1515
F 21788
8
13
23
16
22
22
F X22178
24
25
F 10756
F 10756
Y 19581
34
"
M
A
X
.
2'
-
1
0
"
10" - 24" MAX
46
"
M
A
X
.
3'
-
5
"
EXISTING ITEMS TO PRESERVE AND RELOCATE
A BLENDERS (2)
B ESPRESSO MACHINES (2)
C SAFE
Q WATER FILLING STATION
K WARMING OVEN (2)
T 2-DR REACH IN FRIDGE (2)
S 2-DR REACH IN FREEZER
D WARMING U/C FRIDGE (2)
P MANAGER'S STATION EQUIPMENT
R 1-DR REACH IN FREEZER
E 1-DR U/C FRIDGE (5)
M DRIVE-THRU POS EQUIPMENT
L POS EQUIPMENT, PRINTER, & PHONE
H NITRO TAP / NITRO GENERATOR
G CUP LABELER (4)
F GRINDER
V THAW RACK
U SANITIZER
W R.O. SYSTEM & WATER HEATER
X TRASH BIN
I NOT USED
J CUP CADDY (2)
N PASTRY CART
O AV DIGITAL PRODUCTION MANAGER Y METRO RACKS (10)
Z ICE BIN
A1 HAND DRYER (2)
B1 DATA RACK
C1 LOCKERS (2)
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
8
/
2
0
2
4
2
:
4
0
:
1
9
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I101
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
FF & E PLAN
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
1/4" = 1'-0"1FURNITURE, FIXTURES AND EQUIPMENT PLAN 1" = 1'-0"ATRASH & RECYCLE CART ACCESSIBILITY
N
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
A
A
2301 N Tustin Ave
#A8/22/2024
A. GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION MANAGER IMMEDIATELY
IF A DISCREPANCY EXISTS BETWEEN CASEWORK SHOP DRAWINGS, EXITING
SITE CONDITIONS, ARCHITECTURAL DRAWINGS OR BUILT FIXTURES. ALL
DIMENSIONS SHALL BE FIELD VERIFIED BY GC PRIOR TO SHOP DRAWINGS
PRODUCTION.
B. STARBUCKS CONSTRUCTION MANAGER TO COORDINATE AND SCHEDULE
CASEWORK DELIVERY DATE. GENERAL CONTRACTOR TO CONFIRM
CASEWORK DELIVERY DATE WITH CASEWORK MANUFACTURER AT FOUR (4)
WEEKS PRIOR AND THEN ONE (1) WEEK PRIOR TO SCHEDULED DATE OF
DELIVERY.
C. STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK VENDOR TO SUPPLY
CASEWORK LISTED IN THE CASEWORK SCHEDULE, UNLESS OTHERWISE
NOTED.
D. CASEWORK VENDOR TO PROVIDE COMPLETE SHOP DRAWINGS AND
INSTALLATION PACKAGE TO GENERAL CONTRACTOR TO FACILITATE
PROPER INSTALLATION.
E. ALL CASEWORK BOX BASE / TOE KICKS SHALL BE SET AND LEVELED USING 1/4"
(6 MM) NON-ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR.
F. SEE INTERIOR FINISH ELEVATIONS AND SCHEDULES FOR LOCATION AND
TAGGING OF WALL TREATMENTS BY CV AND OTHERS.
G. SEE REFLECTED CEILING PLAN FOR CASEWORK SOFFIT
LOCATIONS.
H. REFERENCE PLUMBING AND ELECTRICAL PLANS FOR PLACEMENT OF
ELECTRICAL, DATA AND PLUMBING ON FRONT AND BACKLINE OF BAR.
I. PROVIDE ACCENT LIGHTING AT FRONT EDGE OF BAR. SEE INTERIOR
ELEVATIONS AND ELECTRICAL FOR ADDITIONAL INFORMATION.
J. CASEWORK VENDOR TO ENGINEER PROPER COUNTERTOP SUPPORT AT
ESPRESSO BAR AND OTHER WORKSTATIONS PER STARBUCKS MINIMUM
PERFORMANCE REQUIREMENTS.
K. REFER TO CASEWORK INSTALLATION MANUAL PROVIDED BY CASEWORK
VENDOR FOR COMPLETE INSTALLATION INSTRUCTIONS.
L. SEE SHEET I-601 FOR SCHEDULES.
M. G.C. TO MODIFY CASEWORK PER CASEWORK DETAILS.
N. STORAGE RACKS OR SHELVINGS OVER 5'-9" IN HEIGHT SHALL BE
MECHANICALLY SECURED.
KEYNOTES
GENERAL NOTES
1 INSTALL CASEWORK, COUNTERTOPS, SHELVES, CUBBIES, FINISHES,
TRIM AND TABLE TOPS THROUGHOUT. REFERENCE FINISH
SCHEDULE AND MANUFACTURER'S SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
2 ALL COUNTERTOPS UTILIZED FOR CUSTOMER TRANSACTIONS,
INCLUDING BAR, CONDIMENT AND SALES COUNTERTOPS SHALL BE
INSTALLED AT 2'-10" (860 MM) MAXIMUM A.F.F.
3 VARIABLE WIDTH FILLER CABINET / COUNTERTOP REQUIRED TO
FILL GAP (FIELD VERIFY DIMENSION). VENDOR TO COORDINATE
EXACT DIMENSION WITH GC PRIOR TO INSTALLATION
4 DIMENSION CONTROL DATUM POINT
5 ALL WOOD EXPOSED TO WET AREAS TO BE FINISHED AND SEALED
W/CLEAR SEALANT
6 REFER TO INTERIOR FINISH ELEVATIONS FOR VERTICAL TRIMS.
INDICATES STAINLESS STEEL (SST) COUNTERTOP
LEGEND
INDICATES SOLID SURFACE (SS) COUNTERTOP
DATUM POINT
2' - 8 1/4"1' - 3"1' - 3"9"2' - 1 1/2"1' - 3"
2'
-
0
"
C X23709
PL0027
4
I401A
1
I401
1
BACKBAR
RETAIL
SEATING
AREA
WORKROOM
PARTNER /
MANAGER
AREA
UNISEX
CUSTOMER
RESTROOM
UNISEX
PARTNER
RESTROOM
ADJACENT
TENANT
(NIC)
C X1007
WD0073
MAD101-V
C 20369
1 2
I401
2
I401A
2
3 5
6
6
I502C
11
1/
4
"
1'
-
1
0
"
1/
4
"
1'
-
1
0
"
1/
4
"
1'
-
1
0
"
1/
4
"
3/4"
1 1/4"
10 3/4"
PL0027
C X1002
4
INDICATES HORIZONTAL 1" x 1" METAL TRIM - MT0029 -
CHALKBOARD RESIN COATING
C X1009
INDICATES FULL HEIGHT WOOD WALL CLADDING -
WD0073 + MAD101-V
C X1007
INDICATES HORIZONTAL 1/8" x 1/8" METAL CORNER
GUARD TRIM - MT0029 - CHALKBOARD RESIN COATING
C X1005
INDICATES SOFFIT WALL CLADDING - PL0027PL0027
1/
2
"
1'
-
2
"
1/
2
"
3'
-
4
"
1/2"
5 1/2"
1/2"
4
PL0027
C X0017
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
0
6
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I102
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
CASEWORK PLAN
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
N
1/2" = 1'-0"4SIREN UPPER CASEWORK PLAN
1/4" = 1'-0"1CASEWORK PLAN
N
Revision Schedule
Rev Date By Description
1/2" = 1'-0"2PARTNER UPPER CASEWORK PLAN1/2" = 1'-0"3DT UPPER CASEWORK PLAN
NN
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
KEYNOTES GENERAL NOTES
A. WHERE ACOUSTICAL CEILING MEETS WALL, PROVIDE ANGLE WALL MOLDING
FOR REVEAL. MATCH CEILING GRID COLOR WHEN APPLICABLE.
B. LEAVE (10) ADDITIONAL RETAIL CEILING TILES, TO MATCH RETAIL CEILING PAINT
COLOR, ABOVE THE WORKROOM CEILING AT MANAGER'S DESK FOR FUTURE
USE.
C. PROVIDE GROMMET AT ALL CEILING PENETRATIONS FOR FIXTURES OR
SUPPORTS.
D. HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SHOWN FOR DESIGN
INTENT ONLY. REFER TO MECHANICAL DRAWINGS IF APPLICABLE PER SCOPE.
E. DIFFUSERS AND RETURNS AT BACKBAR IN ACOUSTICAL CEILING TILE TO BE
CENTERED IN TILE, PAINTED TO MATCH ADJACENT FINISHES - TYP.(IF
APPLICABLE)
F. PAINT ALL HVAC DUCTS, HVAC DIFFUSERS AND LIGHT TRIM RINGS TO MATCH
ADJACENT CEILING OR SOFFIT PAINT COLOR - TYPICAL THROUGHOUT RETAIL
PORTION OF STORE.
G. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL
ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. SEE SHEET I601 & I602 FOR
SCHEDULES.
H. COORDINATE DUCT LOCATION AND DIFFUSER SIZE WITH MECHANICAL
DRAWINGS.
I. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
J. ALL PAINTED SURFACES TO RECEIVE MINIMUM ONE COAT OF PRIMER. REFER
TO PAINT SCHEDULE FOR SPECIFICATIONS (SHEET I-601 & I-602).
K. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
L. ADJUST FOCUS OF ALL TRACK AND RECESSED DIRECTIONAL LIGHTING TO
FULLY ILLUMINATE ALL ARTWORK, MENU BOARDS, AND MERCH BAYS.
M. FILL, PATCH, AND REPAIR AREAS OF GYP. BD. CEILING AT BACKBAR AND STORE
PERIMETER WHERE EXISTING LIGHTS HAVE BEEN REMOVED DURING
DEMOLITION.
N. ARMSTRONG CEILING TILES PER STARBUCKS SPECIFICATIONS. CALL TO
VERIFY NUMBERS. MATCH COLORS AS INDICATED ON PLAN. CONTACT:
PHYLLIS MILLER (800) 442-4212.
O. LIGHTING AT WORKROOM AND LIGHTS IDENTIFIED WITH "NL" (NIGHT LIGHT) TO
BE ON A 24 HR LOCK-ON CIRCUIT.
P. GENERAL CONTRACTOR SHALL PROVIDE DIMMER FOR INCANDESCENT
LIGHTING IN SEATING AREA.
Q. LIGHTING FIXTURES IN A.C.T. TO BE CENTERED IN CEILING TILE - U.N.O.
R. LIGHT FIXTURES TO BE LOCATED AT PRE-DETERMINED LOCATIONS IN
CASEWORK.
S. LOCATE EMERGENCY / EXIT LIGHTS ABOVE CENTERLINE DOOR OPENINGS
U.N.O. EMERGENCY LIGHTS TO BE PROVIDED WITH 90 MINUTE BATTERY BACK-
UP POWER SUPPLY.
T. ALL LIGHTS ABOVE BACKBAR AREA TO BE SHATTER PROOF.
U. GENERAL CONTRACTOR TO ADJUST THE LENGTH OF EACH PENDANT LIGHT
CORD PER THE NOTED A.F.F. HEIGHT.
V. REFER TO RESTROOM ELEVATIONS (SHEET I-411) FOR MOUNTING HEIGHT OF
RESTROOM WALL SCONCE.
W. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI-
RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS
CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN
GYPSUM SOFFIT OVER FRONTBAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT.
GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO
STARBUCKS'CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO
INSTALLATION.
X. GENERAL CONTRACTOR TO PROVIDE AND LOCATE SPRINKLERS PER LOCAL
CODES. CONTACT STARBUCKS CONSTRUCTION MANAGER IF DESIGN INTENT IS
AFFECTED.
Y. REFERENCE LOW VOLTAGE PLAN SHEET AND ELECTRICAL DRAWINGS.
Z. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI-
RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS
CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED
IN GWB SOFFIT OVER FRONT BAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT.
GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS'
CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION.
AA. DATA CABLING ABOVE HEAD SHALL BE IN PLENUM WHEN AVAILABLE.
BB. DATA CABLING AT EXPOSED CEILING SHALL BE INSTALLED IN METAL CONDUIT
OR PER LOCAL CODE REQUIREMENT.
2 NEW PAINTED GYP.BD. CEILING AT RESTROOM
7 NEW CAFE / RETAIL / BACKBAR / WORKROOM / RESTROOM /
PARTNER REST LIGHTING
1 NEW PAINTED GYP. BD. CEILING AT BACKBAR
9 NEW OMNI-AA HVAC SUPPLY DIFFUSER. REFER TO MECHANICAL
DRAWINGS FOR MORE INFROMATION
8 EXISTING EMERGENCY LIGHT/SIGN TO REMAIN.
4 NEW 2X4 WASHABLE ACT AT WORKROOM. MANUF: ARMSTRONG,
MODEL: CLEANROOM VL-870
3 OPEN TO STRUCTURE ABOVE. PAINT BOTTOM OF DECK AND
TRUSSES TO MATCH SW7031
14 PLATFORM FOR HEATER AND WATER FILTRATION. LIFT CEILING THIS
AREA ONLY TO INSURE ADEQUATE CLEARANCE FOR SERVICING.
13 EXISTING 42" DOOR ACTIVATED AIR CURTAIN TO REMAIN.
6 NEW SUSPENDED SOUND ABATEMENT ZINTRA BAFFLES.
TRAVERTINE DARK FINISH PER SCHEDULES
15 NEW PENDANT SPEAKER AT 11' -2' A.F.F., TYP.
16 NEW CEILING RECESSED SPEAKER.
5 NEW PAINTED GYP. BD CELING AT PARTNER/MANAGER AREA
10 NEW 50F HVAC RETURN DIFFUSER. REFER TO MECHANICAL
DRAWINGS FOR MORE INFROMATION
11 RELOCATED EXISTING HVAC SUPPLY DIFFUSER. REFER TO
MECHANICAL DRAWINGS FOR MORE INFORMATION
12 RELOCATED EXISTING HVAC RETURN DIFFUSER. REFER TO
MECHANICAL DRAWINGS FOR MORE INFORMATION
17 RELOCATED EXISTING RESTROOM EXHAUST FAN DIFFUSER
18 DASHED LINE INDICATES LED LIGHT TAPE HOUSED WITHIN SOFFIT
LIGHT COVE
19 DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE
UPPER CBE CABINETRY
20 DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE
FRONTLINE COUNTERTOP BELOW
21 DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE
PARTNER REST UPPER CABINETRY
22 NEW TITUS 4FT SLOT LINEAR DIFFUSER. REFER TO MECHANICAL
DRAWINGS FOR MORE INFORMATION
23 NEW LUTRON LIGHTING CONTROL PANEL. REFER TO ELECTRICAL
DRAWINGS FOR MORE INFORMATION
24 PROVIDE POWER FOR DIGITAL MENU BOARDS PER DETAIL 4/I504.
REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION
25 EXISTING ELECTRICAL PANELS TO REMAIN
26 NEW DT WINDOW WITH AIR CURTAIN WITHIN TRANSOM. PROVIDE
POWER PER ELECTRICAL DRAWINGS.
27 GC TO PAINT ALL THE TRUSSES, DUCTWORK, AND SCRIM ABOVE
THE BAFFLES THE SAME COLOR AS SOFFIT -SW7031 MEGA GREIGE
28 DASHED LINE INDICATES PREVIOUS LOCATION OF SUPPLY/RETURN
HVAC DIFFUSER.
29 DASHED LINE INDICATES PREVIOUS LOCATION OF RESTROOM
EXHAUS FAN.
LEGEND
TRACK LIGHTING
ELEVATION DATUM
STRIP LIGHTING
PENDANT LIGHT
EXIT SECURITY LIGHT
SUPPLY AIR
RETURN AIR
TROFFER
MUSIC SYSTEM
PENDANT SPEAKER
RESTROOM WALL SCONCE
ADJUSTABLE RECESSED CAN LIGHT - 800LM - FLOOD - WHITE
WALL WASH CAN LIGHT - 1000LM - WHITE
ADJUSTABLE RECESSED CAN LIGHT - 700LM - WF - WHITE
ADJACENT
TENANT
(NIC)
A 22972
A 22970 (3)
L 20662
L 21772
L 21772
L 20661
L 21776
L 19409
L 21779
L 21774
L 20748
L 21774
L 20748
L 21774
L 21783
L 21772
BACKBAR
RETAIL
SEATING
AREA
WORKROOM
PARTNER /
MANAGER
AREA
UNISEX
PARTNER
RESTROOM
UNISEX
CUSTOMER
RESTROOM
(N) 2X4 ACT AT
10' -0" AFF
4
(N) GYP BD CEILING
AT 10' -11" AFF
SW7031 (SG)
1
BACKBAR
(N) GYP BD CEILING
AT 9' -6" AFF
SW7031 (SG)
1
(N) SOFFIT AT 7'-10 3/4" AFF
PL0027
(N) SOFFIT AT 11'-10" AFF
SW7031 (ES)
(N) HEADER AT
9' -6" AFF
FRP FINISH
(N) 2X4 ACT ABOVE RO
& WH AT 12'-6" AFF
(N) GYP BD CEILING
AT 9' -0" AFF
SW7031
(ES)
(N) GYP BD CEILING
AT 9' -0" AFF
SW7031 (SG)
2 (N) GYP BD CEILING
AT 9' -0" AFF
SW7031 (SG)
2
(N) GYP BD CEILING
AT 10' -11" AFF
SW7031 (ES)
1
L 21774
(3)
(32)
(6)
L 21772 (14)
L 21772
(4)
(6)
(2)
(2)
(2)
(2)
(N) HEADER
AT 7' -0" AFF
L 22216
L 22216
L 22220
L 22220
L 22216
(7)
L 21776
UPLIGHT:C
DOWNLIGHT:C
UPLIGHT:C
DOWNLIGHT:B
+
(N) ZINTRA
ACOUSTICAL
BAFFLES AT
11' -2" AFF
A 19493 (4)
A 10015
A 10015
3
5
6
7
7
7
7
7
7
7
7
7
7 8
9999
9 9
99
9
10
10
11
1111
11
12
12
13
14
L 19411
L 21779 (3)
L 19409
L 21779
L 19409
L 21779 (2)
L 19409
L 21779
L 19409
L 21779
F X19620
TYP.
15
16
17
17
18
18
19
20
21
22
2222
2222
22
24
25 23
9
9
26
8
11
16
7' - 0"
(N) HEADER
SW7031
(ES)
FINISH: TRAVERTINE DARK
1
I501A
3
I501A
10
10
28 28
28
28
28
28
28
29
29
27
7' - 0"
(N) FRP HEADER
MANUF: ARMSTRONG
MODEL: CLEANROOM
VL-870
MANUF: ARMSTRONG
MODEL: CLEANROOM
VL-870
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
5
/
2
0
2
4
1
0
:
2
2
:
1
7
A
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I103
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
REFLECTED CEILING
PLAN
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
1/4" = 1'-0"1REFLECTED CEILING PLAN
N
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
A
A
A
A
A
2301 N Tustin Ave
#A8/22/2024
KEYNOTES GENERAL NOTES
A. WHERE ACOUSTICAL CEILING MEETS WALL, PROVIDE ANGLE WALL MOLDING
FOR REVEAL. MATCH CEILING GRID COLOR WHEN APPLICABLE.
B. LEAVE (10) ADDITIONAL RETAIL CEILING TILES, TO MATCH RETAIL CEILING PAINT
COLOR, ABOVE THE WORKROOM CEILING AT MANAGER'S DESK FOR FUTURE
USE.
C. PROVIDE GROMMET AT ALL CEILING PENETRATIONS FOR FIXTURES OR
SUPPORTS.
D. HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SHOWN FOR DESIGN
INTENT ONLY. CONTACT PROJECT MANAGER IF CHANGED.
E. DIFFUSERS AND RETURNS AT BACKBAR IN ACOUSTICAL CEILING TILE TO BE
CENTERED IN TILE, PAINTED TO MATCH ADJACENT FINISHES - TYP.
F. PAINT ALL HVAC DUCTS, HVAC DIFFUSERS, RECESSED SPEAKERS AND LIGHT
TRIM RINGS TO MATCH ADJACENT CEILING OR SOFFIT PAINT COLOR - TYPICAL
THROUGHOUT RETAIL PORTION OF STORE.
G. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL
ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. SEE SHEET I-601 & I-602
FOR SCHEDULES.
H. COORDINATE DUCT LOCATION AND DIFFUSER SIZE WITH MECHANICAL
DRAWINGS.
I. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
J. ALL PAINTED SURFACES TO RECEIVE MINIMUM ONE COAT OF PRIMER. REFER
TO PAINT SCHEDULE FOR SPECIFICATIONS (SHEET I-601 & I-602).
K. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
L. ADJUST FOCUS OF ALL TRACK AND RECESSED DIRECTIONAL LIGHTING TO FULLY
ILLUMINATE ALL ARTWORK, MENU BOARDS, AND MERCH BAYS.
M. FILL, PATCH, AND REPAIR AREAS OF GYP. BD. CEILING AT BACKBAR AND STORE
PERIMETER WHERE EXISTING LIGHTS HAVE BEEN REMOVED DURING
DEMOLITION.
N. ARMSTRONG CEILING TILES PER STARBUCKS SPECIFICATIONS. CALL TO VERIFY
NUMBERS. MATCH COLORS AS INDICATED ON PLAN. CONTACT: PHYLLIS
MILLER (800) 442-4212.
O. LIGHTING AT WORKROOM AND LIGHTS IDENTIFIED WITH "NL" (NIGHT LIGHT) TO
BE ON A 24 HR LOCK-ON CIRCUIT.
P. GENERAL CONTRACTOR SHALL PROVIDE DIMMER FOR INCANDESCENT LIGHTING
IN SEATING AREA.
Q. LIGHTING FIXTURES IN A.C.T. TO BE CENTERED IN CEILING TILE - U.N.O.
R. LIGHT FIXTURES TO BE LOCATED AT PRE-DETERMINED LOCATIONS IN
CASEWORK.
S. LOCATE EMERGENCY / EXIT LIGHTS ABOVE CENTERLINE DOOR OPENINGS U.N.O.
EMERGENCY LIGHTS TO BE PROVIDED WITH 90 MINUTE BATTERY BACK-UP
POWER SUPPLY.
T. ALL LIGHTS ABOVE BACKBAR AREA TO BE SHATTER PROOF.
U. GENERAL CONTRACTOR TO ADJUST THE LENGTH OF EACH PENDANT LIGHT
CORD PER THE NOTED A.F.F. HEIGHT.
V. REFER TO RESTROOM ELEVATIONS (SHEET I-411) FOR MOUNTING HEIGHT OF
RESTROOM WALL SCONCE.
W. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI-
RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS
CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN
GYPSUM SOFFIT OVER FRONTBAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT.
GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO
STARBUCKS'CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO
INSTALLATION.
X. GENERAL CONTRACTOR TO PROVIDE AND LOCATE SPRINKLERS PER LOCAL
CODES. CONTACT STARBUCKS CONSTRUCTION MANAGER IF DESIGN INTENT IS
AFFECTED.
Y. REFERENCE LOW VOLTAGE PLAN SHEET AND ELECTRICAL DRAWINGS.
Z. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI-
RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS
CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED
IN GWB SOFFIT OVER FRONT BAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT.
GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS'
CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION.
AA. DATA CABLING ABOVE HEAD SHALL BE IN PLENUM WHEN AVAILABLE.
BB. DATA CABLING AT EXPOSED CEILING SHALL BE INSTALLED IN METAL CONDUIT
OR PER LOCAL CODE REQUIREMENT.
1 DIMENSION CONTROL DATUM POINT
2 WORKROOM ACT STARTING POINT.
LEGEND
TRACK LIGHTING
ELEVATION DATUM
STRIP LIGHTING
PENDANT LIGHT
EXIT SECURITY LIGHT
SUPPLY AIR
RETURN AIR
TROFFER
MUSIC SYSTEM
PENDANT SPEAKER
RESTROOM WALL SCONCE
ADJUSTABLE RECESSED CAN LIGHT - 800LM - FLOOD - WHITE
WALL WASH CAN LIGHT - 1000LM - WHITE
ADJUSTABLE RECESSED CAN LIGHT - 700LM - WF - WHITE
EQ 3' - 2"EQ
EQ
EQ
EQ
2'
-
9
"
EQ
EQ 3' - 6"3' - 6"EQ
EQ
3'
-
6
"
EQ
EQ EQ
EQ EQ
EQ
2'
-
1
0
"
EQ
2' - 0"2' - 4"21' - 8"4"
13
'
-
1
0
1
/
4
"
3'
-
1
0
"
7'
-
1
0
1
/
2
"
LI
G
H
T
C
O
V
E
4"
2'
-
2
3
/
4
"
LI
G
H
T
C
O
V
E
4"
1' - 0"
2' - 6"
3' - 2 1/2"
1'
-
0
"
2'
-
0
"
3'
-
2
"
3'
-
1
"
3'
-
1
"
6' - 5"3' - 11"3' - 4"3' - 11"3' - 2"3' - 11"
5' - 9"3' - 11"2' - 5"3' - 11"5' - 8"
3'
-
9
"
7'
-
7
1
/
4
"
1'
-
5
"
2'
-
0
"
2'
-
0
"
23' - 8"
1'
-
1
0
"
1'
-
8
"
1'
-
8
"
1'
-
8
"
2'
-
3
1
/
2
"
3' - 2 1/4"3' - 11"2' - 0"
1' - 9"12' - 4"
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
1' - 1 1/2"
1
2
2' - 7"6' - 10"25' - 8"
I103B
1
Sim
BACKBAR
RETAIL
SEATING
AREA
WORKROOM
UNISEX
PARTNER
RESTROOM
PARTNER /
MANAGER
AREA
PARTNER /
MANAGER
AREA
BACKBAR
UNISEX
CUSTOMER
RESTROOM
EQ
EQ
3' - 8 1/2"1' - 6"
EQ EQ EQ EQ EQ 1' - 11"EQ
EQ EQ EQ EQ
1'
-
9
"
EQ
EQ
1'
-
4
1
/
4
"
10
'
-
7
"
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
1
3
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I103A
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
REFLECTED CEILING
DIMENSION PLAN
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
N
3/8" = 1'-0"1REFLECTED CEILING DIMENSION PLAN
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
KEYNOTES
GENERAL NOTES
A. WHERE ACOUSTICAL CEILING MEETS WALL, PROVIDE ANGLE WALL MOLDING
FOR REVEAL. MATCH CEILING GRID COLOR WHEN APPLICABLE.
B. LEAVE (10) ADDITIONAL RETAIL CEILING TILES, TO MATCH RETAIL CEILING PAINT
COLOR, ABOVE THE WORKROOM CEILING AT MANAGER'S DESK FOR FUTURE
USE.
C. PROVIDE GROMMET AT ALL CEILING PENETRATIONS FOR FIXTURES OR
SUPPORTS.
D. HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SHOWN FOR DESIGN
INTENT ONLY. CONTACT PROJECT MANAGER IF CHANGED.
E. DIFFUSERS AND RETURNS AT BACKBAR IN ACOUSTICAL CEILING TILE TO BE
CENTERED IN TILE, PAINTED TO MATCH ADJACENT FINISHES - TYP.
F. PAINT ALL HVAC DUCTS, HVAC DIFFUSERS, RECESSED SPEAKERS AND LIGHT
TRIM RINGS TO MATCH ADJACENT CEILING OR SOFFIT PAINT COLOR - TYPICAL
THROUGHOUT RETAIL PORTION OF STORE.
G. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL
ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. SEE SHEET I-601 & I-602
FOR SCHEDULES.
H. COORDINATE DUCT LOCATION AND DIFFUSER SIZE WITH MECHANICAL
DRAWINGS.
I. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
J. ALL PAINTED SURFACES TO RECEIVE MINIMUM ONE COAT OF PRIMER. REFER
TO PAINT SCHEDULE FOR SPECIFICATIONS (SHEET I-601 & I-602).
K. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
L. ADJUST FOCUS OF ALL TRACK AND RECESSED DIRECTIONAL LIGHTING TO FULLY
ILLUMINATE ALL ARTWORK, MENU BOARDS, AND MERCH BAYS.
M. FILL, PATCH, AND REPAIR AREAS OF GYP. BD. CEILING AT BACKBAR AND STORE
PERIMETER WHERE EXISTING LIGHTS HAVE BEEN REMOVED DURING
DEMOLITION.
N. ARMSTRONG CEILING TILES PER STARBUCKS SPECIFICATIONS. CALL TO VERIFY
NUMBERS. MATCH COLORS AS INDICATED ON PLAN. CONTACT: PHYLLIS
MILLER (800) 442-4212.
O. LIGHTING AT WORKROOM AND LIGHTS IDENTIFIED WITH "NL" (NIGHT LIGHT) TO
BE ON A 24 HR LOCK-ON CIRCUIT.
P. GENERAL CONTRACTOR SHALL PROVIDE DIMMER FOR INCANDESCENT LIGHTING
IN SEATING AREA.
Q. LIGHTING FIXTURES IN A.C.T. TO BE CENTERED IN CEILING TILE - U.N.O.
R. LIGHT FIXTURES TO BE LOCATED AT PRE-DETERMINED LOCATIONS IN
CASEWORK.
S. LOCATE EMERGENCY / EXIT LIGHTS ABOVE CENTERLINE DOOR OPENINGS U.N.O.
EMERGENCY LIGHTS TO BE PROVIDED WITH 90 MINUTE BATTERY BACK-UP
POWER SUPPLY.
T. ALL LIGHTS ABOVE BACKBAR AREA TO BE SHATTER PROOF.
U. GENERAL CONTRACTOR TO ADJUST THE LENGTH OF EACH PENDANT LIGHT
CORD PER THE NOTED A.F.F. HEIGHT.
V. REFER TO RESTROOM ELEVATIONS (SHEET I-411) FOR MOUNTING HEIGHT OF
RESTROOM WALL SCONCE.
W. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI-
RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS
CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN
GYPSUM SOFFIT OVER FRONTBAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT.
GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO
STARBUCKS'CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO
INSTALLATION.
X. GENERAL CONTRACTOR TO PROVIDE AND LOCATE SPRINKLERS PER LOCAL
CODES. CONTACT STARBUCKS CONSTRUCTION MANAGER IF DESIGN INTENT IS
AFFECTED.
Y. REFERENCE LOW VOLTAGE PLAN SHEET AND ELECTRICAL DRAWINGS.
Z. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI-
RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS
CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED
IN GWB SOFFIT OVER FRONT BAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT.
GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS'
CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION.
AA. DATA CABLING ABOVE HEAD SHALL BE IN PLENUM WHEN AVAILABLE.
BB. DATA CABLING AT EXPOSED CEILING SHALL BE INSTALLED IN METAL CONDUIT
OR PER LOCAL CODE REQUIREMENT.
1 DIMENSION CONTROL DATUM POINT
3' - 2 1/2"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"1' - 11"1' - 10"1' - 10"
1' - 6 1/2"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"1' - 6 1/2"
1' - 8"8' - 8 1/2"6' - 8 1/2"3' - 6"3' - 6"3' - 6"7' - 6 1/2"
10
'
-
6
1
/
2
"
8'
-
9
3
/
4
"
5'
-
6
3
/
4
"
1'
-
3
1
/
4
"
1' - 10"
2' - 7"
1' - 7"2' - 0"2' - 0"2' - 0"2' - 0"7' - 11"
2' - 0"2' - 0"2' - 0"7' - 0"
1'
-
9
"
2'
-
1
0
3
/
4
"
7'
-
6
3
/
4
"
2'
-
0
"
2'
-
0
"
2'
-
0
1
/
4
"
8'
-
0
3
/
4
"
BACKBAR
BACKBAR
HO
L
D
2"
3' - 5"
1
1
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
1
4
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I103B
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ENLARGED SOFFIT
DIMENSION PLAN
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
1/2" = 1'-0"1ENLARGED SOFFIT REFLECTED CEILING DIMENSION PLAN
N
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
KEYNOTES
GENERAL NOTES
A. ALL TILE TO BE INSTALLED PER TILE COUNCIL OF AMERICA STANDARDS.
B. STARBUCKS TO SUPPLY FLOORING AND BASE FOR FRONT AND BACK OF
HOUSE AS NOTED IN SCHEDULES. GENERAL CONTRACTOR TO INSTALL.
GENERAL CONTRACTOR TO SUPPLY WORKROOM TILE AND BASE AND INSTALL.
GENERAL CONTRACTOR TO SUPPLY AND INSTALL MORTAR, ADHESIVE, AND
GROUT. GENERAL CONTRACTOR TO INSPECT ALL TILES AND REJECT
DAMAGED OR SUBSTANDARD TILES PRIOR TO
C. ALL FLOORING AND BASE MATERIAL TO BE INSTALLED ACCORDING TO
STARBUCKS SPECIFICATIONS.
D. ALIGN TILE TRANSITIONS ON WHOLE TILES WHEREVER POSSIBLE.
E. FOR WALK-OFF MAT / CARPET TILE INSTALLATION, REFER TO MANUFACTURER'S
INSTALLATION INSTRUCTIONS.
F. FOR ALL FLOOR AND BASE TILE INSTALLATIONS AT CASEWORK, MECHANICALLY
SAND AND SCARIFY WOOD SUBSTRATE TO COMPLETELY REMOVE ALL FINISH.
TROWEL ONE PRIMER COAT OF MAPEI TYP 1, KER 903 ADHESIVE AND ALLOW TO
AIR DRY.
G. TILE BASE AND THRESHOLD GROUT JOINTS TO ALIGN WITH TILE FLOOR GROUT
JOINTS.
H. REMOVAL OF EXCESS GROUT WILL BE DONE WITH WATER. THE USE OF
SULFURIC OR MURIATIC ACID IS PROHIBITED. IF THESE ACIDS ARE USED, THE
INSTALLER WILL BE REQUIRED TO REMOVE THE ACID AND RESTORE THE
GROUT AT THEIR EXPENSE.
I. PROVIDE GROUT JOINT OF 3/16" MAXIMUM DEVIATION OF TILE AND GROUT LINE
OF 1/4" PER 4'.
J. ADD OR REMOVE EXISTING TILE AND BASE AS REQUIRED BY SCOPE OF WORK.
K. EXISTING FLOORING AND WALL BASE TO REMAIN - U.N.O. REPLACE TILE
DAMAGED BY DEMOLITION OR CONSTRUCTION.
L. CORNERS AND EDGES OF TILE TO BE BULLNOSE. NO OUTSIDE GROUT
CORNERS OR RAW TILE EDGES ARE ALLOWED.
M. ALL WALLS AND CASEWORK OUTLINES / TOE KICK RECEIVE BASE AS NOTED.
N. REFER TO INTERIOR ELEVATIONS FOR BACKBAR WALL TILE LOCATION.
O. REFER TO SHEET I402 FOR RESTROOM WALL TILE LOCATION.
P. REFER TO SHEET I601 & I602 FOR SCHEDULES.
Q. FLOOR-WALL JUNCTURES AT BACKBAR WILL HAVE 3/8" RADIUS COVE, MINIMUM
4" HIGH.
R. WORKROOM TO BE FINISHED PER LOCAL CODE REQUIREMENTS.
S. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL
BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY CLEANABLE.
PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH-GLOSS FINISH
1 NEW FLOOR SINK.
2 6" CONCRETE CURB FOR FOOD CASE AND SAFE.
3 TILE START POINT WHERE INDICATED.
4 REFER TO ENLARGED RESTROOM PLAN ON SHEET I402 FOR MORE
INFORMATION
5 WALK-OFF MAT AT ENTRY. SEE INTERIOR DETAIL SHEETS FOR
TRANSITION.
6 MOP SINK WHERE INDICATED. SEE PLUMBING PLANS FOR MORE
INFORMATION.
7 10" CONCRETE CURB AT MOP SINK. FINISH WITH ECOGRIP UP TO 6"
ABOVE CURB WITH 3/8" COVE RADIUS.
8 LOCATION OF CASEWORK SST LEG SUPPORT.
9 FLOOR FINISH TRANSITION POINT.
BACKBAR
RETAIL
SEATING
AREA
WORKROOM
PARTNER /
MANAGER
AREA
UNISEX
PARTNER
RESTROOM
UNISEX
CUSTOMER
RESTROOM
ADJACENT
TENANT
(NIC)
1
1
1
1
1
1
1
12
2
7
6
8
8
T 19289
5
T 20262
T 20262
T 20259
T 20259
T 20259
3
6' - 0"
4'
-
0
"
T 19795
T 19795
4
4
B 18735
B 18735
B 18735
B X19795
B X19795
B 18735
B 18735
TYP.
9
9
1
I503
2
I503
4
I503
6
I503
8
I503
8
I503
9
I503
TYP.
10
I503
11
I503
14
I503
17
I503
2
I402
T 19288
FLOOR FINISH LEGEND
T 20262
T 19795
T 20259
T 19289
B 18735
POLYVINYLE ECOGRIP FLOORING @ WORKROOM
& BACKBAR
MANUFACTURER: ALLIED ECO-GRIP, INC.
COLOR: PEWTER
NEW WALK-OFF MAT @ STORE ENTRY
MANUFACTURER: IMPACT SPECIALITIES
TYPE / MODEL: HELIX Z2 & HELIX Z1
B X19795
POLYVINYL ECOGRIP FLOORING WRAPS UP 6" ON
WALLS AND CABINETS WITH 3/8" COVE RADIUS @
WORKROOM AND BACKBAR
MANUFACTURER: ALLIED ECO-GRIP, INC.
COLOR: PEWTER
FLOOR TILE AT CAFE
MANUFACTURER: STONEPEAK
TYPE / MODEL: FIANDRE - FRENCH CLAY - 24" X 24"
COLOR / FINISH: CAFE - MATTE
WALL BASE AT CAFE, PARTNER/ MANAGER AREA,
AND RESTROOMS
MANUFACTURER: DALTILE
TYPE / MODEL: PLAZA NOVA - 6" X 12"
COLOR: WHITE IMAGE
FLOOR TILE AT PARTNER AREA AND RESTROOMS
MANUFACTURER: STONEPEAK
TYPE / MODEL: FMG - VENICE VILLA - 24" X 24"
COLOR / FINISH: IVORY - NATURAL
T 19288
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
1
6
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I104
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
FLOOR FINISH PLAN
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
1/4" = 1'-0"1FLOOR FINISH PLAN
N
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
KEYNOTES
GENERAL NOTES
A. GENERAL PAINT NOTES:
1. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS ACCOUNT
"COLOR CODE" WHEN ORDERING PAINTS.
2. TO LOCATE THE NEAREST SHERWIN WILLIAMS STORE, CALL (800) 321-8194.
ORDER PAINT BY STARBUCKS COFFEE COMPANY PROGRAM "COLOR
CODE". PAINT FORMULAS FOR "COLOR CODE" AVAILABLE AT (800)
321-8194. FURTHER INFORMATION AVAILABLE THROUGH ED STEIN AT (888)
731-7379.
3. SUBMIT TWO (2) SETS OF 8.5" X 11" BRUSH-OUTS OF ALL PAINT COLORS
AND FINISHES TO THE STARBUCKS CONSTRUCTION MANAGER FOR
APPROVAL PRIOR TO PAINTING.
4. REFER TO INTERIOR ELEVATIONS FOR COLOR LOCATIONS.
5. ALL WOOD AND METAL SURFACES SHALL BE PAINTED SEMI-GLOSS - U.N.O.
6. WALL RECEIVING VINYL MURAL WALLCOVERING SHALL BE SMOOTH AND
PVC PRIMED. MURALS TO BE SEALED. SEALER IS PROVIDED WITH MURAL.
B. PROVIDE AND INSTALL FULL-HEIGHT F.R.P. @ MOP SINK ENCLOSURE AND ALL
NEW WORKROOM WALLS.
C. PAINT COLOR TRANSITIONS ALLOWED AT CORNERS ONLY.
D. REFER TO INTERIOR ELEVATIONS FOR GRAPHICS LOCATIONS.
E. REFER TO CASEWORK FINISH SCHEDULE ON SHEET I601 FOR FURTHER
CASEWORK FINISH INFORMATION.
F. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL
FINISHES.
G. REFER TO INTERIOR ELEVATIONS AND REFLECTED CEILING PLAN FOR PAINT
CALL OUTS.
H. REFER TO SHEET I-601 FOR WALL TILE INFORMATION.
I. COORDINATE WINDOW SHADE LOCATIONS WITH STARBUCKS CONSTRUCTION
MANAGER.
J. G.C. TO APPLY F.R.P. TO ALL SIDES OF CABINET INTERIOR & WALLS UNDER
COUNTER.
K. INSTALL FRY REGLET CORNER TRIM PIECES AS NEEDED IN FRONT OF HOUSE
WHERE DRYWALL TO DRYWALL CORNERS EXIST WITH NO PROVIDED
WAINSCOT PROTECTION. ITEM IS G.C. PROVIDED DURING DRYWALL TAPING
PROCESS. TRIM PIECE CAN BE FIELD PAINTED. IF TO BE PAINTED, G.C. TO
REQUEST DMCT - 375 WITH CHEM FILM - A PAINTABLE SURFACE APPLIED BY
THE SUPPLIER AT NO ADDITIONAL COST.
L. REFER TO I402 FOR RESTROOM FINISH INFORMATION.
1 INSTALL NEW FULL HEIGHT F.R.P. AT NEW WORKROOM WALLS
2 INSTALL BACKBAR WALL TILE USING STACKED VERTICAL PATTERN
@ EXPOSED WALL SURFACE BETWEEN BASE OF UPPER CUBBIES
AND TOP OF BACKSPLASH AND BEHIND WARMING OVENS AND
UNDERCOUNTER FRIDGES.
3 INSTALL NEW F.R.P. AT BACK BAR CABINETS BELOW COUNTERTOPS
AT HIDDEN AREAS.
4 ENLARGED RESTROOM ELEVATION REFER TO I402
5 REFER TO INTERIOR ELEVATIONS FOR PAINT LOCATION & TYPE
6 PROVIDE SST CORNER GUARD AT WORKROOM.
WALL FINISH LEGEND
NEW CERAMIC WALL TILE AT BACKBAR,
PARTNER REST AREA, AND CUSTOMER
RESTROOM
MANUFACTURER: UNITED TILE CORP
TYPE / MODEL: MOSA - 4" X 12"
COLOR: UNBLEACHED WHITE
Q 22817
SW7103
INDICATES SHERWIN WILLIAMS SEMI-GLOSS
PAINT AT BACKBAR AND RESTROOM, AND
EGGSHELL PAINT AT CAFE AND PARTNER /
MANAGER AREA
COLOR: WHITETAIL
INDICATES ARTWORK PER SCHEDULEG 21491
WAINSCOTT WALLCOVERING + 1" X 1" METAL
CHAIR RAIL - MD0029 @3' - 1" AFF
TYPE / MODEL: TEXTURGLAS - TG21
HERRINGBONE
PAINT COLOR: WILLOW TREE
Q 11469 INDICATES FRP FINISH AT WORKROOM AND
PARTNER RESTROOM
COLOR: WHITE
INDICATES WALLCOVERING AT CAFE
TYPE / MODEL: TEXTURGLAS - TG21
HERRINGBONE
PAINT COLOR: LAUREL WOODS
Q 17778
G 22043
G 22922
SW7741
Q 17778
SW7749
INDICATES SOFFIT WALL CLADDING - PL0027
INDICATES FULL HEIGHT WOOD WALL
CLADDING AT CAFE - WD0073CX1007
WD0073
ADJACENT
TENANT
(NIC)
BACKBAR
RETAIL
SEATING
AREA
WORKROOM
PARTNER /
MANAGER
AREA
UNISEX
PARTNER
RESTROOM
UNISEX
CUSTOMER
RESTROOM
1
2 3 5
5
5
5
4
4
I201
3
1
I202 13
I201
15
I203
2
1
4
I203
11
12
I204 1
I204
9
2
10
6
I202 14
13
16
15
I204 34
12
I205
2
3
4
20
I503
16
I503
6
6
6 6
I2033
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
1
7
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I105
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
WALL FINISH PLAN
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
1/4" = 1'-0"1WALL FINISH PLAN
N
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND
EQUIPMENT (FF & E) SCHEDULES ON SHEET I601.
B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH
ARTWORK/GRAPHICS FOR PROPER INSTALLATION.
C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE
INDICATED.
D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE:
1) WOODS AND METAL SURFACES SHALL BE
SEMI-GLOSS OR EQUAL.
2) ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL.
a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL.
3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR
EQUAL.
E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL
ACCOUNT COLOR CODE WHEN ORDERING PAINTS.
F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL
BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY
CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH.
G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE
SEALED.
H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON
SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION.
I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN.
J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION
AREAS SHALL HAVE A 6" COVED BASE.
K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F.
L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING
BACK BAR TILE.
M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL
FINISHES.
N. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE - RUN BACKBAR WALL
TILE TO UNDERSIDE OF WALL CABINETS - NOT BEHIND CABINETS.
O. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
P. ALL PAINTED SURFACES TO RECEIVE A MINIMUM ONE COAT OF PRIMER. SEE
PAINT SCHEDULE FOR SPECIFICATIONS.
Q. PAINT SHALL NOT BE APPLIED OVER EXISTING MURALS OR VINYL
WALLCOVERING.
R. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
S. SEE I402 ENLARGED RESTROOM PLAN DETAILS FOR ACCESSORY MOUNTING
HEIGHTS.
T. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT
ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
U. CASEWORK, COUNTERTOPS AND WALL MOUNTED FURNISHINGS TO BE
ATTACHED TO SUPPORTING MEMBERS PER PRODUCT MANUFACTURER'S
SPECIFICATIONS.
V. TILE BASE - REFER TO I104 FOR DESIGN ID TAG AND DETAILS.
KEYNOTES
GENERAL NOTES
1 NEW ARTWORK -REFER TO SCHEDULE "G" ON SHEET I601
2 ALIGN TOP OF 1" X 1" HORIZONTAL METAL TRIM WITH TOP OF
STOREFRONT MULLION
3 EXISTING MAIN ENTRY/EXIT DOOR TO BE REMAINED.
4 EXISTING EMERGENCY EXIT LIGHT/SIGN TO BE REMAINED IN PLACE
7 36" DOOR ACTUATOR PUSH PLATE
6 ACCESSIBLE UNISEX RESTROOM SIGNAGE -SEE DETAIL 3/G004
8 DOOR ACTUATOR OPERATOR DEVICE.
9 DOOR ACTUATOR CAUTION SIGN.
10 RESTROOM DOOR. FINISHED PER SCHEDULE
12 NEW RECYCLE STATION
11 NEW ROLLER SHADE.
13 NEW WOOD PANELING -WD0077 MAD101-V
14 DOOR ACTUATOR KEY SWITCH.
5 EXISTING STOREFRONT TO REMAIN. WINDOWS ARE FIXED AND NOT
OPERABLE.
INDICATES WALL BLOCKING. BLOCKING TO BE
PROVIDED AS REQUIRED TO SUPPORT WALL
ATTACHMENTS. EXTEND BLOCKING 4" (100mm)
BEYOND EDGE OF ATTACHMENTS.
LEGEND
WALL TILE START POINT DATUM
6"
2'
-
1
0
"
5'
-
0
"
6'
-
6
"
10
'
-
1
1
"
B.
O
.
B
A
F
F
L
E
S
11
'
-
2
"
B.
O
.
E
X
I
S
T
I
N
G
R
O
O
F
15
'
-
4
"
V
I
F
10
'
-
1
1
"
11
'
-
1
0
"
B 18735 WD0073
MAD303-V
SW7031 SW7031
CP0030
SW7031
(ES)
(ES)
13
TY
P
.
2
1
/
4
"
CP0030
6"
10
'
-
1
1
"
B.
O
.
T
R
A
C
K
L
I
G
H
T
11
'
-
0
1
/
2
"
B.
O
.
B
A
F
F
L
E
S
11
'
-
2
"
15
'
-
4
"
3'
-
9
"
2'
-
6
"
7'
-
1
0
3
/
4
"
B.
O
.
L
I
G
H
T
F
I
X
T
U
R
E
10
'
-
4
3
/
4
"
10
'
-
1
1
1
/
4
"
11
'
-
1
0
"
B 18735
G 22043
3"
2'
-
1
1
1
/
2
"
4
3
/
4
"
G 23136
D 23135 13
D 23129 15
D 23130 10
SW7103
SW7749
Q 17778
SW7749
Q 17778
SW7103
SW7103
WD0073
C X1009
MT0029
SW7103
SW7103SW7103
(ES)
(ES)(ES)
(ES)
(ES)
(ES)
EQEQ
1
2
3
4
5 5
7
8
14
9
F X22488 F X22488
F X22488 F X22488
11 11
11 11
12
1' - 10"
B 18735
GTK0074
SW7031
WD0073
WD0073
MAD101-V
C X1007
SW7749
Q 17778
6"
10
'
-
1
1
"
6'
-
1
3
/
4
"
(ES)
(ES)
6
10
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
1
9
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I201
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
INTERIOR FINISH
ELEVATIONS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
Revision Schedule
Rev Date By Description
3/8" = 1'-0"1CAFE ELEVATION A
3/8" = 1'-0"3CAFE ELEVATION C3/8" = 1'-0"15CAFE ELEVATION E
NOT USED
B 18735
GTK0074
SW7031
WD0073
WD0073
MAD101-V
C X1007
SW7749
Q 17778
6"
10
'
-
1
1
"
6'
-
1
3
/
4
"
(ES)
(ES)
6
10
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND
EQUIPMENT (FF & E) SCHEDULES ON SHEET I601.
B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH
ARTWORK/GRAPHICS FOR PROPER INSTALLATION.
C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE
INDICATED.
D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE:
1) WOODS AND METAL SURFACES SHALL BE
SEMI-GLOSS OR EQUAL.
2) ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL.
a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL.
3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR
EQUAL.
E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL
ACCOUNT COLOR CODE WHEN ORDERING PAINTS.
F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL
BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY
CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH.
G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE
SEALED.
H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON
SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION.
I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN.
J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION
AREAS SHALL HAVE A 6" COVED BASE.
K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F.
L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING
BACK BAR TILE.
M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL
FINISHES.
N. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE - RUN BACKBAR WALL
TILE TO UNDERSIDE OF WALL CABINETS - NOT BEHIND CABINETS.
O. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
P. ALL PAINTED SURFACES TO RECEIVE A MINIMUM ONE COAT OF PRIMER. SEE
PAINT SCHEDULE FOR SPECIFICATIONS.
Q. PAINT SHALL NOT BE APPLIED OVER EXISTING MURALS OR VINYL
WALLCOVERING.
R. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
S. SEE I402 ENLARGED RESTROOM PLAN DETAILS FOR ACCESSORY MOUNTING
HEIGHTS.
T. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT
ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
U. CASEWORK, COUNTERTOPS AND WALL MOUNTED FURNISHINGS TO BE
ATTACHED TO SUPPORTING MEMBERS PER PRODUCT MANUFACTURER'S
SPECIFICATIONS.
V. TILE BASE - REFER TO I104 FOR DESIGN ID TAG AND DETAILS.
KEYNOTES
GENERAL NOTES
1 ARTWORK -REFER TO SCHEDULE "G" ON SHEET I601
2 WALL MOUNTED OSB "ORDER STATUS BOARD". PROVIDE POWER
PER DETAIL 3/I504
4 1" X 1" HORIZONTAL METAL TRIM -MT0029
3 EXISTING STOREFRONT TO REMAIN. WINDOWS ARE FIXED AND NOT
OPERABLE.
5 RELOCATED EXISTING ENERGY MANAGEMENT SYSTEM.
6 TRIM AROUND THE OPENING. 1" X 1" WOOD + SW7741 PAINT
7 FULL HEIGHT WALL WOOD CLADDING. WD0073 + MAD101-V
8 NEW ROLLER SHADE.
INDICATES WALL BLOCKING. BLOCKING TO BE
PROVIDED AS REQUIRED TO SUPPORT WALL
ATTACHMENTS. EXTEND BLOCKING 4" (100mm)
BEYOND EDGE OF ATTACHMENTS.
LEGEND
WALL TILE START POINT DATUM
6"
7'
-
1
0
3
/
4
"
LI
G
H
T
C
O
V
E
6"
10
'
-
1
1
"
LI
G
H
T
C
O
V
E
6"
10
'
-
1
1
"
15
'
-
4
"
V
I
F
2'
-
1
0
"
5"
WD0073
MAD101-V
C X1007
G 22922
SW7103
SW7103
B 18735
SW7031SW7031
B.
O
.
B
A
F
F
L
E
S
11
'
-
2
"
(ES)
(ES)
(ES)
1
7
I502C
9
6"
2'
-
1
0
"
3'
-
3
"
4'
-
1
0
"
6'
-
6
"
7'
-
1
0
3
/
4
"
10
'
-
1
1
"
3'
-
9
3
/
4
"
3'
-
8
3
/
4
"
6"
3'
-
9
"
2'
-
6
"
6'
-
2
"
7'
-
1
0
3
/
4
"
10
'
-
1
1
"
A 22970
A 23021 Q 22817
CP0030
SW7103SW7103
SW7749
Q 17778
G 21491
WD0073
B 18735
(SG)(ES)
(ES)
CP0030
MT0029
C X1009
MT0029
C X1009
EQ EQ
1
2
3
4 4
F X22488 F X22488 F X22488 F X22488
8 8 8 8
1' - 10"
MT0029
SW7103
SW7741
Q 17778
C X1009
OPEN TO
PARTNER
AREA
(ES)
(ES)
3'
-
1
"
9'
-
0
"
B 18735
4
B 18735
MT0029
Q 17778
SW7103
SW7741
C X1009
(ES)
(ES)
6"
3'
-
1
"
9'
-
0
"
SW7103(ES)
5
4
SW7741
MT0029
SW7103
Q 17778
B 18735
C X1009
6"
3'
-
1
"
9'
-
0
"
(ES)
(ES)
4
Q 17778
SW7741
SW7103
MT0029
C X1009
B 18735
(ES)
(ES)
6"
3'
-
1
"
9'
-
0
"
7'
-
0
"
4
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
2
1
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I202
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
INTERIOR FINISH
ELEVATIONS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
Revision Schedule
Rev Date By Description
3/8" = 1'-0"1CAFE ELEVATION B
3/8" = 1'-0"3CAFE ELEVATION D
3/8" = 1'-0"13MANAGER AREA ELEVATION A
3/8" = 1'-0"14MANAGER AREA ELEVATION B
3/8" = 1'-0"15MANAGER AREA ELEVATION C
3/8" = 1'-0"16MANAGER AREA ELEVATION D
6"
7'
-
1
0
3
/
4
"
LI
G
H
T
C
O
V
E
6"
10
'
-
1
1
"
LI
G
H
T
C
O
V
E
6"
10
'
-
1
1
"
15
'
-
4
"
V
I
F
2'
-
1
0
"
5"
WD0073
MAD101-V
C X1007
G 22922
SW7103
SW7103
B 18735
SW7031SW7031
B.
O
.
B
A
F
F
L
E
S
11
'
-
2
"
(ES)
(ES)
(ES)
1
7
I502C
9
6"
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND
EQUIPMENT (FF & E) SCHEDULES ON SHEET I601.
B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH
ARTWORK/GRAPHICS FOR PROPER INSTALLATION.
C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE
INDICATED.
D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE:
1) WOODS AND METAL SURFACES SHALL BE
SEMI-GLOSS OR EQUAL.
2) ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL.
a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL.
3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR
EQUAL.
E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL
ACCOUNT COLOR CODE WHEN ORDERING PAINTS.
F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL
BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY
CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH.
G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE
SEALED.
H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON
SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION.
I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN.
J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION
AREAS SHALL HAVE A 6" COVED BASE.
K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F.
L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING
BACK BAR TILE.
M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL
FINISHES.
N. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE - RUN BACKBAR WALL
TILE TO UNDERSIDE OF WALL CABINETS - NOT BEHIND CABINETS.
O. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
P. ALL PAINTED SURFACES TO RECEIVE A MINIMUM ONE COAT OF PRIMER. SEE
PAINT SCHEDULE FOR SPECIFICATIONS.
Q. PAINT SHALL NOT BE APPLIED OVER EXISTING MURALS OR VINYL
WALLCOVERING.
R. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
S. SEE I402 ENLARGED RESTROOM PLAN DETAILS FOR ACCESSORY MOUNTING
HEIGHTS.
T. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT
ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
U. CASEWORK, COUNTERTOPS AND WALL MOUNTED FURNISHINGS TO BE
ATTACHED TO SUPPORTING MEMBERS PER PRODUCT MANUFACTURER'S
SPECIFICATIONS.
V. TILE BASE - REFER TO I104 FOR DESIGN ID TAG AND DETAILS.
KEYNOTES
GENERAL NOTES
1 1/8" SOFFIT CLADDING REVEAL, TYP.
2 ALIGN TOP OF 1" X 1" METAL TRIM WITH BOTTOM OF SOFFIT
3 WALL FINISH BEHIND EXPOSED CABINETRY AND BELOW UNDERSIDE
OF COUNTERTOP SUBSTRATE TO BE FRP.
4 NEW 1" X 1" METAL TRIM -MT0029
5 EXISTING STOREFRONT TO REMAIN. WINDOWS ARE FIXED AND NOT
OPERABLE.
6 RELOCATED EXISITNG TEMPERATURE SENSOR
7 RELOCATED EXISTING OCCUPANCY SENSOR
8 TRAFFIC DOOR, FINISHED PER SCHEDULE
9 PROVIDE POWER/DATA FOR DIGITAL MENU BOARDS PER DETAIL
1/I504
10 PROVIDE 6" MIN. SST INTEGRAL SPLASHGUARD AT HAND SINK ON
BOTH SIDES
11 NEW DRIVE THRU WINDOW.
INDICATES WALL BLOCKING. BLOCKING TO BE
PROVIDED AS REQUIRED TO SUPPORT WALL
ATTACHMENTS. EXTEND BLOCKING 4" (100mm)
BEYOND EDGE OF ATTACHMENTS.
LEGEND
WALL TILE START POINT DATUM
5"
2'
-
1
0
"
4'
-
1
0
"
7'
-
1
0
3
/
4
"
10
'
-
1
1
"
Q 22817
PL0027
MT0029
C X1009
TYP.
A 22970
A 22972
(3)
PL0027
PL0003CP0030
PL0027
Q 22817
TYP.TYP.B X19795
3'
-
1
0
"
5'
-
0
"
11' - 0 1/4"6' - 7 1/4"
2'
-
1
"
8'
-
1
1
/
4
"
7'
-
0
"
TYP.
2' - 1 1/2"
1
2
33
4
8
9
10
6"
6"
2'
-
1
0
"
5'
-
0
"
10
'
-
1
1
"
4'
-
1
0
"
B X19795
TYP.
CP0030 TYP.
6'
-
6
"
OPEN TO CAFE
6"
7'
-
7
"
9'
-
6
"
7'
-
9
3
/
4
"
10
'
-
1
1
"
11
'
-
5
"
8'
-
4
3
/
4
"
6"
6"
SW7103
MT0029
C X1009
Q 22817
B X19795
Q 22817
(SG)
(SG)SW7103MT0029
C X1009
PL0003 PL0003 PL0003
4
4
2'
-
1
0
"
5"
2'
-
1
0
"
6"
7'
-
1
0
3
/
4
"
LI
G
H
T
C
O
V
E
6"
10
'
-
1
1
"
LI
G
H
T
C
O
V
E
6"
7'
-
1
0
3
/
4
"
B X19795 B 18735
MT0029
SW7749
Q 22817
SW7103 C X1009
(SG)(ES)
Q 17778
4
6
7
I502C
3
6"
6"
2'
-
1
0
"
3'
-
3
"
9'
-
6
"
7'
-
7
"
MT0029
SW7103
Q 22817
B X19795
C X1009
PL0003
CP0030
(SG)
3
4
11
5
10
WX21987
I203
14
2'
-
1
0
"
5"7'
-
0
"
9'
-
6
"
6"
7'
-
7
"
PL0003
MT0029
SW7103
Q 22817 C X1009
CP0030
B X19795
(SG)
3
4
OPEN TO
BACKBAR
2"4' - 1 1/2"2"
2"
9"
2"
2'
-
1
1
3
/
4
"
11
I501
12
I501
15
I501
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
6
/
2
0
2
4
1
2
:
1
2
:
0
8
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I203
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
INTERIOR FINISH
ELEVATIONS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
3/8" = 1'-0"1BACKBAR ELEVATION A
3/8" = 1'-0"2BACKBAR ELEVATION B
3/8" = 1'-0"3BACKBAR ELEVATION D
3/8" = 1'-0"4BACKBAR ELEVATION C3/8" = 1'-0"12BACKBAR ELEVATION E
3/8" = 1'-0"11BACKBAR ELEVATION F
NOT USED
3/4" = 1'-0"14ENLARGED DT WINDOW
Revision Schedule
Rev Date By Description
2301 N Tustin Ave
#A8/22/2024
A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND
EQUIPMENT (FF & E) SCHEDULES ON SHEET I601.
B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH
ARTWORK/GRAPHICS FOR PROPER INSTALLATION.
C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE
INDICATED.
D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE:
1) WOODS AND METAL SURFACES SHALL BE
SEMI-GLOSS OR EQUAL.
2) ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL.
a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL.
3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR
EQUAL.
E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL
ACCOUNT COLOR CODE WHEN ORDERING PAINTS.
F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL
BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY
CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH.
G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE
SEALED.
H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON
SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION.
I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN.
J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION
AREAS SHALL HAVE A 6" COVED BASE.
K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F.
L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING
BACK BAR TILE.
M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL
FINISHES.
N. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE - RUN BACKBAR WALL
TILE TO UNDERSIDE OF WALL CABINETS - NOT BEHIND CABINETS.
O. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
P. ALL PAINTED SURFACES TO RECEIVE A MINIMUM ONE COAT OF PRIMER. SEE
PAINT SCHEDULE FOR SPECIFICATIONS.
Q. PAINT SHALL NOT BE APPLIED OVER EXISTING MURALS OR VINYL
WALLCOVERING.
R. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
S. SEE I402 ENLARGED RESTROOM PLAN DETAILS FOR ACCESSORY MOUNTING
HEIGHTS.
T. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT
ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
U. CASEWORK, COUNTERTOPS AND WALL MOUNTED FURNISHINGS TO BE
ATTACHED TO SUPPORTING MEMBERS PER PRODUCT MANUFACTURER'S
SPECIFICATIONS.
V. TILE BASE - REFER TO I104 FOR DESIGN ID TAG AND DETAILS.
KEYNOTES
GENERAL NOTES
14 RELOCATED EXISTING LOCKERS.
15 PARTNER REST AREA COAT HOOK.
1 RELOCATED EXISTING DATA RACK.
2 WALL FINISH BEHIND EXPOSED CABINETRY AND BELOW UNDERSIDE
OF COUNTERTOP SUBSTRATE TO BE FRP.
8 NEW LUTRON PANEL.
3 NEW ACCESSIBLE UNISEX RESTROOM SIGNAGE -SEE DETAIL 3/G004
4 EXISTING STOREFRONT TO REMAIN. WINDOWS ARE FIXED AND
NON-OPERABLE.
5 EXISTING ELECTRICAL PANELS TO REMAIN IN PLACE.
6 RELOCATED EXISTING FIRE EXTINGUSHER
7 WALL MOUNT HAND SINK WITH SOAP AND PAPER TOWEL
DISPENSER. G.C. TO PROVIDE BLOCKING FOR FASTENERS.
9 ACCESSIBLE UNISEX RESTROOM SIGNAGE -SEE DETAIL 3/G004
10 TRIM AROUND THE OPENING. 1" X 1" WOOD + SW7741 PAINT
11 PARTNER RECOGNITION BOARD. PROVIDED BY ARTWORK VENDOR.
12 NEW RESTROOM DOOR. FINISHED PER SCHEDULE
13 NEW 1" X 1" METAL TRIM -MT0029
16 PARTNER REST AREA MIRROR.
17 RELOCATED OCCUPANCY SENSOR.
INDICATES WALL BLOCKING. BLOCKING TO BE
PROVIDED AS REQUIRED TO SUPPORT WALL
ATTACHMENTS. EXTEND BLOCKING 4" (100mm)
BEYOND EDGE OF ATTACHMENTS.
LEGEND
WALL TILE START POINT DATUM
6"
2'
-
1
0
"
5"
7'
-
7
"
9'
-
6
"
7'
-
1
0
3
/
4
"
10
'
-
1
1
"
LI
G
H
T
C
O
V
E
6"
LI
G
H
T
C
O
V
E
6"PL0027
MT0029
C X1009
SW7103
Q 22817
B X19795
OPEN TO
BACKBAR
PL0003 PL0003 TYP.
CP0030
(SG)
13
2
OPEN TO
WORKROOM
6"
3'
-
1
"
9'
-
0
"
4'
-
3
"
1'
-
4
1
/
2
"
4'
-
0
"
5"
2'
-
1
0
"
5'
-
0
"
B.
O
.
H
E
A
D
E
R
7'
-
0
"
SW7103
MT0029
Q 17778
SW7741
SW7103
B 18735
C X1009
CP0030
(ES)
(ES)
(ES)
13
16
15
(ES)
9'
-
0
"
Q 22817
PL0003
PL0027
SW7103
PL0027
B 18735
14
2
6"
2'
-
1
0
"
5"
5'
-
0
"
CP0030
OPEN TO
MANAGER
AREA
WD0073
6"
3'
-
1
"
9'
-
0
"
2'
-
1
0
"
5"
3'
-
3
"
5'
-
0
"
SW7741
Q 17778
MT0029
SW7103SW7741
B 18735
C X1009
(ES)
(ES)
(ES)
12
9
13
B.
O
.
H
E
A
D
E
R
7'
-
0
"
6"
3'
-
1
"
9'
-
0
"
3'
-
5
"
4'
-
0
"
MT0029
SW7741
Q 17778
SW7103
C X1009
B 18735
(ES)
(ES)
13
11
GX22178
3' - 10"
EQ EQ
WD0073
2'
-
0
"
6"
10
'
-
0
"
B X19795
Q 11469
8
55
17
Q 11469
Q 11469
B X19795
6"
10
'
-
0
"
4'
-
6
"
4'
-
8
"
7 6
OPEN TO
PARTNER
AREA
B X19795
Q 11469Q11469
6"
10
'
-
0
"
1
B.
O
.
H
E
A
D
E
R
7'
-
0
"
17
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
:
4
7
:
2
9
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I204
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
INTERIOR FINISH
ELEVATIONS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
Revision Schedule
Rev Date By Description
3/8" = 1'-0"1BACKBAR ELEVATION G3/8" = 1'-0"9PARTNER REST ELEVATION A
3/8" = 1'-0"2PARTNER REST ELEVATION B3/8" = 1'-0"10PARTNER REST ELEVATION C 3/8" = 1'-0"6PARTNER REST ELEVATION D
3/8" = 1'-0"3WORKROOM ELEVATION B
3/8" = 1'-0"4WORKROOM ELEVATION D3/8" = 1'-0"12WORKROOM ELEVATION C
NOT USED
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
INDICATES WALL BLOCKING. BLOCKING TO BE
PROVIDED AS REQUIRED TO SUPPORT WALL
ATTACHMENTS. EXTEND BLOCKING 4" (100mm)
BEYOND EDGE OF ATTACHMENTS.
LEGEND
WALL TILE START POINT DATUM
A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND
EQUIPMENT (FF & E) SCHEDULES ON SHEET I601.
B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH
ARTWORK/GRAPHICS FOR PROPER INSTALLATION.
C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE
INDICATED.
D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE:
1) WOODS AND METAL SURFACES SHALL BE
SEMI-GLOSS OR EQUAL.
2) ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL.
a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL.
3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR
EQUAL.
E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL
ACCOUNT COLOR CODE WHEN ORDERING PAINTS.
F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL
BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY
CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH.
G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE
SEALED.
H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON
SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION.
I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN.
J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION
AREAS SHALL HAVE A 6" COVED BASE.
K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F.
L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING
BACK BAR TILE.
M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL
FINISHES.
N. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE - RUN BACKBAR WALL
TILE TO UNDERSIDE OF WALL CABINETS - NOT BEHIND CABINETS.
O. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
P. ALL PAINTED SURFACES TO RECEIVE A MINIMUM ONE COAT OF PRIMER. SEE
PAINT SCHEDULE FOR SPECIFICATIONS.
Q. PAINT SHALL NOT BE APPLIED OVER EXISTING MURALS OR VINYL
WALLCOVERING.
R. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
S. SEE I402 ENLARGED RESTROOM PLAN DETAILS FOR ACCESSORY MOUNTING
HEIGHTS.
T. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT
ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
U. CASEWORK, COUNTERTOPS AND WALL MOUNTED FURNISHINGS TO BE
ATTACHED TO SUPPORTING MEMBERS PER PRODUCT MANUFACTURER'S
SPECIFICATIONS.
V. TILE BASE - REFER TO I104 FOR DESIGN ID TAG AND DETAILS.
KEYNOTES
GENERAL NOTES
1 NEW TRAFFIC DOOR. FINISH PER SCHEDULE.
2 NEW MOP HOOK
3 NEW ICE MACHINE/ DIVERTER/ ICE BIN ADAPTOR PEDESTAL. (SEE
PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL
INFORMATION).
4 EXISTING EMERGENCY EXIT SIGN/LIGHT TO REMAIN IN PLACE.
5 EXISTING AIR CURTAIN ABOVE DOOR TO REMAIN.
6 EXISTING EXIT ONLY DOOR WITH SURLOCK TO REMAIN.
7 RELOCATED EXISITNG TEMPERATURE SENSOR
B X19795
Q 11469
6"
10
'
-
0
"
10
"
6"
7'
-
0
"
12
'
-
6
"
9'
-
6
"
6
4 5
3
B X19795
Q 11469 Q 11469
6"
10
'
-
0
"
10
"
7'
-
0
"
6"
9'
-
6
"
12
'
-
6
"
PL0027
1
3
2
5'
-
1
0
"
10
"
7'
-
0
"
6"
12
'
-
6
"
B X19795
Q 11469
Q 11469
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
3
1
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I205
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
INTERIOR FINISH
ELEVATIONS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
Revision Schedule
Rev Date By Description
3/8" = 1'-0"2WORKROOM ELEVATION A
3/8" = 1'-0"3WORKROOM ELEVATION E
3/8" = 1'-0"4WORKROOM ELEVATION F
NOT USEDNOT USED
NOT USEDNOT USED
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
KEYNOTES
GENERAL NOTES
A. GENERAL CONTRACTOR TO SCHEDULE WITH LOCAL REFRIGERATION
CONTRACTOR TO CONDUCT INITIAL FOOD CASE START-UP AND TESTING.
FOR APPROVED CONTRACTOR, CONTACT VENDOR.
B. THE SITE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM
UNLESS OTHERWISE NOTED.
C. ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION
FOUNDATION STANDARDS OR EQUIVALENT.
D. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS,
EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR
ACCUMULATION OF DUST, DIRT AND DEBRIS.
E. WARMING OVEN(S) SHOWN FOR PERMITTING PURPOSES. INSTALLATION AT
STORE OPENING TO BE VERIFIED BY STARBUCKS CONSTRUCTION
REPRESENTATIVE.
F. EACH HAND WASHING SINK WILL HAVE A SINGLE SERVICE TOWEL AND SOAP
DISPENSER, AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR
PREMIXING FAUCET.
G. SEE SHEET I601 FOR SCHEDULES.
H. G.C. TO CONFIRM CASEWORK DELIVERY DATE WITH CONSTRUCTION
MANAGER PROVIDING A MINIMUM SCHEDULING NOTICE OF 4 WEEKS AND 1
WEEK PRIOR TO SCHEDULED DATE OF DELIVERY.
I. SEE WALL FINISH PLAN FOR LOCATION, TAGGING AND FINISH SCHEDULES OF
APPLIED WALL TREATMENT.
J. EDIBLE PRODUCTS TO BE PHYSICALLY SEPARATED FROM STORAGE OF NON-
EDIBLE OR TOXIC PRODUCTS.
K. NO VEGETABLE OR FOOD PREPARATION ON THE PREMISES.
L. NO ALCOHOLIC BEVERAGES TO BE SOLD OR CONSUMED ON THE PREMISES.
M. THE MAXIMUM NUMBER OF EMPLOYEES PER SHIFT SHALL NOT EXCEED 4.
N. NON-MOVABLE EQUIPMENT ON THE FLOOR SHALL BE MOUNTED ON 6" LEGS,
CASTERS OR MANUFACTURER SUPPLIED SKIDS.
O. ALL EQUIPMENT, CONSTRUCTION, AND INSTALLATION SHALL MEET ANSI
CERTIFICATION. ALL PLUMBING, GAS LINES AND CONDUITS, ETC., ARE TO BE
CONCEALED WHERE POSSIBLE. OTHERWISE, THEY MUST BE A MINIMUM OF
SIX INCHES OFF THE FLOOR AND NOT RUN ACROSS AISLE SPACE AND TO BE
INSTALLED AT LEAST 1/2" AWAY FROM THE WALL TO FACILITATE CLEANING.
ALL EQUIPMENT AND BACKSPLASHES ARE TO BE ADEQUATELY SEALED TO
THE WALL. DISPLAYS OF UNPACKAGED FOOD ARE TO BE PROTECTED WITH
SNEEZE GUARDS. ALL EXPOSED SURFACES OF SHELVING, CABINETS AND
UNDERCOUNTERS ARE TO BE SMOOTH AND SEALED.
P. G.C. TO CAULK WHERE COUNTERTOPS MEET FOOD CASE (SEAL WITH THE
DEPARTMENT OF ENVIRONMENTAL HEALTH APPROVED CAULKING).
Q. NON-MOVABLE EQUIPMENT ON THE COUNTER SHALL BE MOUNTED ON 4"
LEGS.
R. REFER TO CASEWORK INSTALLATION MANUAL PROVIDED BY CASEWORK
VENDOR FOR COMPLETE INSTALLATION INSTRUCTION.
S. FOR ALL NEW CASEWORK ITEMS BASE UNITS SHALL BE SET ON 1/4" NON-
ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR.
T. CAULK AND SEAL ALL SEAMS BETWEEN SS COUNTERTOPS USING DOW
CORNING BRAND '732 MULTI PURPOSE SEALANT'.
U. STAINLESS STEEL TOP AT CBS STATION TO BE INSTALLED BY G.C.
V. G.C. TO PROVIDE AND INSTALL ANGLE AT OUTSIDE CORNERS TYP. AND
ALONG BOTTOM EDGE OF CASEWORK PANELS.
W. ALL FOOD STORAGE SHALL BE 6" (150mm) A.F.F.
X. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETS) SHALL BE
SEALED.
Y. ALL EQUIPMENT AND CABINETRY WILL BE FLUSH MOUNTED TO COUNTERS,
WALLS OR FLOORS, OR BE RAISED TO ALLOW FOR CLEANING.
Z. CONFIRM ALL NECESSARY EQUIPMENT CLEARANCES PER PRODUCT CUT
SHEET (E.G. ICE MACHINE).
AA. FOR LOCATION OF COUNTERTOP EQUIPMENT, REFER TO CASEWORK
ELECTRICAL DETAILS.
BB. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING DESIGN PLAN. FOR
DATA DEVICE SCHEDULE, REFER TO THE ELECTRICAL DESIGN PLAN.
CC. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM
THE LOCAL JURISDICTION.
1 LED LIGHT STRIP W/HOUSING MOUNTED TO UNDERSIDE OF UPPER
CABINETRY
EXISTING ITEMS TO PRESERVE AND RELOCATE
A BLENDERS (2)
B ESPRESSO MACHINES (2)
C SAFE
Q WATER FILLING STATION
K WARMING OVEN (2)
T 2-DR REACH IN FRIDGE (2)
S 2-DR REACH IN FREEZER
D WARMING U/C FRIDGE (2)
P MANAGER'S STATION EQUIPMENT
R 1-DR REACH IN FREEZER
E 1-DR U/C FRIDGE (5)
M DRIVE-THRU POS EQUIPMENT
L POS EQUIPMENT, PRINTER, & PHONE
H NITRO TAP / NITRO GENERATOR
G CUP LABELER (4)
F GRINDER
V THAW RACK
U SANITIZER
W R.O. SYSTEM & WATER HEATER
X TRASH BIN
I NOT USED
J CUP CADDY (2)
N PASTRY CART
O AV DIGITAL PRODUCTION MANAGER Y METRO RACKS (10)
Z ICE BIN
A1 HAND DRYER (2)
B1 DATA RACK
C1 LOCKERS (2)
P 22768
P 22642
P 11003
P 10153
P 22768
P 10153
P 22642
P 11003
E 19278 E 19278
E 16238
P 10549
P 10152
P 10597
E 10992
E 11115
E 21934
E 23445
E 10992
P 10597
E 11115
E 23444 E 23445
A 23021
A 22970
(2)
E 22885
E 23381
E 23380
E 23442
H
A
A
B B
C
D
E
E E
E
F
G
G
J J
K K
L
M
N
O
I400
2
E
E 12618
D
P 17565
E 17564
P 10153
P 10215
L 22216
E 20010
G
BACKBAR
A 20294
E 10267
G
(2)
L=5'-5 1/2"
1
E 23421
L 22220
E 23420E23419
E 23393
E 23419
E 23393
E 23419
E 23393
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
5
/
2
0
2
4
1
0
:
2
2
:
4
4
A
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I400
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ENLARGED ENGINE
PLAN
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
1/2" = 1'-0"1ENLARGED FF&E PLAN
N
1/2" = 1'-0"2ENLARGED FF&E UPPER PLAN
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
A
2301 N Tustin Ave
#A8/22/2024
A. GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION MANAGER IMMEDIATELY
IF A DISCREPANCY EXISTS BETWEEN CASEWORK SHOP DRAWINGS, EXITING
SITE CONDITIONS, ARCHITECTURAL DRAWINGS OR BUILT FIXTURES. ALL
DIMENSIONS SHALL BE FIELD VERIFIED BY GC PRIOR TO SHOP DRAWINGS
PRODUCTION.
B. STARBUCKS CONSTRUCTION MANAGER TO COORDINATE AND SCHEDULE
CASEWORK DELIVERY DATE. GENERAL CONTRACTOR TO CONFIRM
CASEWORK DELIVERY DATE WITH CASEWORK MANUFACTURER AT FOUR (4)
WEEKS PRIOR AND THEN ONE (1) WEEK PRIOR TO SCHEDULED DATE OF
DELIVERY.
C. STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK VENDOR TO SUPPLY
CASEWORK LISTED IN THE CASEWORK SCHEDULE, UNLESS OTHERWISE
NOTED.
D. CASEWORK VENDOR TO PROVIDE COMPLETE SHOP DRAWINGS AND
INSTALLATION PACKAGE TO GENERAL CONTRACTOR TO FACILITATE
PROPER INSTALLATION.
E. ALL CASEWORK BOX BASE / TOE KICKS SHALL BE SET AND LEVELED USING 1/4"
(6 MM) NON-ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR.
F. SEE INTERIOR FINISH ELEVATIONS AND SCHEDULES FOR LOCATION AND
TAGGING OF WALL TREATMENTS BY CV AND OTHERS.
G. SEE REFLECTED CEILING PLAN FOR CASEWORK SOFFIT
LOCATIONS.
H. REFERENCE PLUMBING AND ELECTRICAL PLANS FOR PLACEMENT OF
ELECTRICAL, DATA AND PLUMBING ON FRONT AND BACKLINE OF BAR.
I. PROVIDE ACCENT LIGHTING AT FRONT EDGE OF BAR. SEE INTERIOR
ELEVATIONS AND ELECTRICAL FOR ADDITIONAL INFORMATION.
J. CASEWORK VENDOR TO ENGINEER PROPER COUNTERTOP SUPPORT AT
ESPRESSO BAR AND OTHER WORKSTATIONS PER STARBUCKS MINIMUM
PERFORMANCE REQUIREMENTS.
K. REFER TO CASEWORK INSTALLATION MANUAL PROVIDED BY CASEWORK
VENDOR FOR COMPLETE INSTALLATION INSTRUCTIONS.
L. SEE SHEET I-601 FOR SCHEDULES.
M. G.C. TO MODIFY CASEWORK PER CASEWORK DETAILS.
N. STORAGE RACKS OR SHELVINGS OVER 5'-9" IN HEIGHT SHALL BE
MECHANICALLY SECURED.
GENERAL NOTES
1' - 3"3' - 9"2' - 6 1/4"3' - 1 1/4"
CLEAR
4' - 4"2' - 6 1/2"
CLEAR - WARMING WALL
3' - 5 3/4"8' - 1 3/4"
CLEAR
4' - 0 1/2"1' - 10"
11' - 7 1/2"
CLEAR
4' - 0 1/2"1' - 10"1' - 3"8' - 11 3/4"1' - 3"
CLEAR
6' - 1 1/2"
7' - 8 1/4"3' - 9"1' - 7"4' - 6"1' - 9"6' - 10"
CLEAR - FOOD CASE
5' - 6 1/4"5 1/2"
CLEAR
3' - 0"
2'
-
6
1
/
2
"
CL
E
A
R
4'
-
6
"
2"
2'
-
6
1
/
2
"
3'
-
4
"
CL
E
A
R
4'
-
8
"
2'
-
6
1
/
2
"
4"
4"
6
1
/
2
"
4"
1'
-
0
1
/
4
"
4"
11 1/2"1 3/4"
9 3/4"1' - 5 3/4"
6"
1'
-
0
"
6"
1'
-
5
1
/
4
"
2
1
/
2
"
2'
-
2
"
7"1' - 5"9' - 2"
1' - 1 1/4"4' - 1"
2' - 3"2' - 3 1/2"
5' - 11"3' - 8 3/4"
1'
-
5
1
/
4
"
1'
-
1
1
"
8"5' - 0"8"5' - 0 1/4"
3' - 7"2' - 3"
2' - 3"4' - 0 1/4"
3'
-
4
1
/
2
"
10
"
6'
-
6
"
10
"
4' - 8"
2' - 6"1' - 10 1/2"
5
1
/
4
"
2'
-
1
"
8
3
/
4
"
8
3
/
4
"
ø 4"
ø 2 1/4"
ø 4"
ø 4"ø 4"
ø 4"
ø 2"
ø 4"
ø 4"
ø 4"ø 4"
ø 3"ø 3"
#4
BRUSHED
16GA CP0030 CP0030 CP0030
CP0030
CP0030
CP0030 CP0030
CP0030
CP0030
#4
BRUSHED
16GA
CP0030
CP0030
1'
-
3
"
6 1/2"
C 17810 C 23433 C 17807 C X17827
C X17895
C 17810
C 17741
C 18883C17830
C 20063
C 20061C20271
C 23409
C 21958
CP0030
C 18720 CP0030
CP0002
BACKBAR
C 10163
r 11 3/4"
5"
1'
-
6
"
1'
-
7
"
ø 4"
ø 3"
8 1/2"
C 20066
CP0030
1
8
"
M
I
N
2'
-
0
"
1
8
"
M
I
N
2'
-
0
"
INDICATES STAINLESS STEEL (SST) COUNTERTOP
LEGEND
INDICATES SOLID SURFACE (SS) COUNTERTOP
DATUM POINT
5'
-
7
1
/
4
"
5 1/4"1' - 4 3/4"9 3/4"
5"
11
1
/
4
"
2' - 7 1/2"
CP0030
C 23151
PARTNER /
MANAGER
AREA
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
8
/
2
0
2
4
2
:
4
0
:
2
0
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I401
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ENLARGED CASEWORK
PLAN
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
1/2" = 1'-0"1ENLARGED COUNTERTOP DIMENSION PLAN
N
1/2" = 1'-0"2ENLARGED PARTNER AREA COUNTERTOP
DIMENSION PLAN
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
AA
2301 N Tustin Ave
#A8/22/2024
INDICATES STAINLESS STEEL (SST) COUNTERTOP
LEGEND
INDICATES SOLID SURFACE (SS) COUNTERTOP
DATUM POINT
BACKBAR
1' - 3"2' - 6"1' - 3"2' - 6 1/4"2' - 10 1/4"3"
3' - 5 3/4"3"2' - 9 3/4"2' - 7 1/4"1' - 3"1' - 3"
3"
2'
-
4
1
/
4
"
1'
-
3
"
1'
-
3
"
1'
-
3
"
3"
2'
-
9
"
1'
-
3
"
2'
-
6
"
5' - 0"1' - 3"1' - 6"1' - 3"2' - 6"4' - 3 1/4"3"
5 1/2"
1' - 3"1' - 3 1/4"1' - 3"2' - 6"1' - 3"1' - 3"2' - 6"1' - 3"
1' - 3"1' - 3"2' - 8 1/4"1' - 3"1' - 3"1' - 0 1/2"2' - 8"1' - 9 1/4"1' - 4 3/4"2' - 11"1' - 9 1/2"2' - 6"1' - 10"2' - 6"5' - 6 1/4"1 1/2"1"
2"
2'
-
4
"
4
3
/
4
"
1
1
/
2
"
1"
2'
-
1
0
1
/
4
"
2"
1
3
/
4
"
2'
-
4
3
/
4
"
2"
2'
-
4
3
/
4
"
1 1/2"
1' - 7 1/4"
2' - 4 3/4"
1
1
/
2
"
2'
-
3
1
/
4
"
C 17810
C 17747 C 23426 C 17573
C 17573
C 20633
C 17747 C 17747
C 17747
C 17573
C X17741
C X17741
C X17741
C 17894
C 19343
C 17894
C 17741 C 17741
C 17574
C 17740 C 17745 C 17896
C 17740
C 17741
C 18885
C 18884
C 21192C 17744C 21192
C 20064 C 17831 C 17832C11155
C 18145 C 20633C21191C21191
C 17747
C 23388 C 17741
C 18865 C 18717
(4)(4)
C 20065
I502C
1
I502
6
17
I502A
1
I502
15
I502
1
I502A
(4)
C 21191 C 21190
A. GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION MANAGER IMMEDIATELY
IF A DISCREPANCY EXISTS BETWEEN CASEWORK SHOP DRAWINGS, EXITING
SITE CONDITIONS, ARCHITECTURAL DRAWINGS OR BUILT FIXTURES. ALL
DIMENSIONS SHALL BE FIELD VERIFIED BY GC PRIOR TO SHOP DRAWINGS
PRODUCTION.
B. STARBUCKS CONSTRUCTION MANAGER TO COORDINATE AND SCHEDULE
CASEWORK DELIVERY DATE. GENERAL CONTRACTOR TO CONFIRM
CASEWORK DELIVERY DATE WITH CASEWORK MANUFACTURER AT FOUR (4)
WEEKS PRIOR AND THEN ONE (1) WEEK PRIOR TO SCHEDULED DATE OF
DELIVERY.
C. STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK VENDOR TO SUPPLY
CASEWORK LISTED IN THE CASEWORK SCHEDULE, UNLESS OTHERWISE
NOTED.
D. CASEWORK VENDOR TO PROVIDE COMPLETE SHOP DRAWINGS AND
INSTALLATION PACKAGE TO GENERAL CONTRACTOR TO FACILITATE
PROPER INSTALLATION.
E. ALL CASEWORK BOX BASE / TOE KICKS SHALL BE SET AND LEVELED USING 1/4"
(6 MM) NON-ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR.
F. SEE INTERIOR FINISH ELEVATIONS AND SCHEDULES FOR LOCATION AND
TAGGING OF WALL TREATMENTS BY CV AND OTHERS.
G. SEE REFLECTED CEILING PLAN FOR CASEWORK SOFFIT
LOCATIONS.
H. REFERENCE PLUMBING AND ELECTRICAL PLANS FOR PLACEMENT OF
ELECTRICAL, DATA AND PLUMBING ON FRONT AND BACKLINE OF BAR.
I. PROVIDE ACCENT LIGHTING AT FRONT EDGE OF BAR. SEE INTERIOR
ELEVATIONS AND ELECTRICAL FOR ADDITIONAL INFORMATION.
J. CASEWORK VENDOR TO ENGINEER PROPER COUNTERTOP SUPPORT AT
ESPRESSO BAR AND OTHER WORKSTATIONS PER STARBUCKS MINIMUM
PERFORMANCE REQUIREMENTS.
K. REFER TO CASEWORK INSTALLATION MANUAL PROVIDED BY CASEWORK
VENDOR FOR COMPLETE INSTALLATION INSTRUCTIONS.
L. SEE SHEET I-601 FOR SCHEDULES.
M. G.C. TO MODIFY CASEWORK PER CASEWORK DETAILS.
N. STORAGE RACKS OR SHELVINGS OVER 5'-9" IN HEIGHT SHALL BE
MECHANICALLY SECURED.
GENERAL NOTES
PARTNER /
MANAGER
AREA
3"
2'
-
7
1
/
4
"
1'
-
3
"
1'
-
3
"
3"
2' - 4 3/4"
C 17573
C 17747
C 17574
C 17573
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
3
7
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I401A
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ENLARGED CASEWORK
PLAN
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
N
1/2" = 1'-0"1ENLARGED CASEWORK PLAN
Revision Schedule
Rev Date By Description
1/2" = 1'-0"2ENLARGED PARTNER AREA CASEWORK
DIMENSION PLAN
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY STARBUCKS
CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO
CONSTRUCTION.
B. ALL DIMENSIONS ARE TO BE TAKEN FROM A DESIGNATED DATUM POINT.
C. DIMENSIONS ARE TO FACE OF FINISHED SURFACE UNLESS OTHERWISE
NOTED.
D. DIAPER CHANGING STATION IS TO BE INSTALLED PER MANUFACTURER’S
INSTRUCTIONS. UNIT IS TO BE FASTENED TO STRUCTURE AT ALL SIX CHASSIS
ATTACHMENT POINTS. (IF APPLICABLE PER PROJECT SCOPE)
E. LOCATE DIAPER CHANGING STATION AS SHOWN TO ALLOW NECESSARY
CLEARANCE FOR OPERATION OF ALL RESTROOM FIXTURES. LOCATION SHALL
NOT IMPEDE ACCESS, EGRESS, OR DOOR SWING. (IF APPLICABLE PER
PROJECT SCOPE)
F. ALL RESTROOM ACCESSORY MOUNTING HEIGHTS AND CLEARANCES SHALL
COMPLY WITH THE ACCESSIBILITY REQUIREMENTS OF THE LOCAL
JURISDICTION.
GENERAL NOTESKEYNOTES
1 60" ACCESSIBLE TURNING SPACE.
2 30" X 48" CLEAR FLOOR SPACE.
3 WATER CLOSET CLEAR FLOOR SPACE.PER CBC 11B-604 13 NEW COAT HOOK.
4 NEW RESTROOM WALL SCONCE, CENTER SCONCE ABOVE MIRROR 14 FULL TILE AT TOP OF TILED WALL.
5 NEW LAVATORY SINK & FAUCET. FLOW RATE NOT TO EXCEED 0.5
GPM AT 60 PSI
9 NEW WATER CLOSET. NOT TO EXCEED 1.28 GALLON PER FLUSH
6 RELOCATED EXISTING ELECTRICAL HAND DRYER
7 NEW SINK MOUNTED SOAP DISPENSER.
8 BOTTOM OF MIRROR REFLECTIVE SURFACE TO BE 40" AFF.
10 NEW RESTROOM GRAB BAR
11 NEW TOILET PAPER DISPENSER.
12 NEW SEAT COVER DISPENSER.
15 NEW RESTROOM DOOR. FINISH PER SCHEDULE.
16 NEW 1" X 1" HORIZONTAL METAL TRIM -MT0029
2' - 0"1' - 0"
3' - 0"
2'
-
9
"
19
"
M
A
X
17
"
M
I
N
1' - 6"
2'
-
9
"
1'
-
7
"
3'
-
5
"
1'
-
6
"
3' - 3"
6"4' - 0"
3' - 3 1/2"5 1/4"
ELECTRIC HAND
DRYER FRONT ELEVATION
4'
-
0
"
COAT
HOOK ELEVATION
TOILET
FRONT ELEVATION
TOILET
SIDE ELEVATION
3'
-
4
"
HAND SINK
SIDE ELEVATION
19" MAX
17" MIN
11" MIN 6" MAX
8" MIN
9"
M
I
N
27
"
M
I
N
29
"
M
I
N
34
"
M
A
X
OF
R
E
F
L
E
C
T
I
V
E
S
U
R
F
A
C
E
40
"
M
A
X
.
T
O
B
O
T
T
O
M
CLEAR KNEE SPACE
WALL MOUNTED LAVATORY
19
"
M
I
N
1'
-
9
1
/
4
"
CEMENTITOUS BACKER
BOARD
CONTINUOUS WATERPROOF
MEMBRANE. EXTEND
12" (305mm) UP WALL.
WALL TILE PER SCHEDULE.
ADHERE TO WALL PER
MFR'S RECOMMENDATIONS.
COVED TILE BASE PER
SCHEDULE. ADHERE TO
WALL PER MFR'S
RECOMMENDATIONS.
3/8" RADIUS AT COVED BASE
FINISH FLOOR PER SCHEDULE
CONTINUOUS WATERPROOF
MEMBRANE APPLIED TO
SUBFLOOR. EXTEND EDGE
TO 12" (305mm) OFFSET
FROM WALL.
CONCRETE SLAB
WALL TYPE PER LEGEND
I402
8
11
10
9
I402
6
4
57
UNISEX
PARTNER
RESTROOM
W.C. CLEARANCE
4' - 8"
CLR
4' - 0"
WHEEL CHAIR TURNING SPACE
ø 5' - 0"
W.
C
.
C
L
E
A
R
A
N
C
E
5'
-
0
"
18
"
M
I
N
1'
-
6
"
17
"
-
1
8
"
1'
-
6
"
W.
C
.
C
L
E
A
R
A
N
C
E
5'
-
0
"
W.C. CLEARANCE
4' - 8"
CLR
4' - 0"
18
"
M
I
N
1'
-
6
"
2'
-
6
"
CLEAR
18" MIN
2'
-
6
"
WHEEL CHAIR TURNING SPACE
ø 5' - 0"
4' - 0"
4' - 0"
UNISEX
CUSTOMER
RESTROOM
1
2
3
1
2
3
17
"
-
1
8
"
1'
-
6
"
12" MAX
7 1/2
"
SW7103
6"
2'
-
9
"
3'
-
4
"
7'
-
3
"
9'
-
0
"
Q 22817
B 18735
14
(SG)
WD0073
SW7031
MT0029
C X1009 16
6
15
6"
2'
-
9
"
B.
O
.
R
E
F
L
E
C
T
I
V
E
S
U
R
F
.
3'
-
3
1
/
4
"
6'
-
3
"
9'
-
0
"
B 18735
Q 22817
SW7103
7'
-
3
"
2'
-
9
1
/
2
"
7
5
10
9
EQ EQ(SG)
MT0029
C X1009
4
16
14
9"
B 18735
Q 22817
6"
2'
-
9
1
/
2
"
9'
-
0
"
7'
-
3
"
SW7103
1'
-
5
"
MT0029
C X1009(SG)
16
10
9 11 12
14
SW7103
Q 22817
B 18735
6"
7'
-
3
"
9'
-
0
"
EQ EQ
4'
-
0
"
MT0029
C X1009(SG)
16
13
14
B 18735
9'
-
0
"
4'
-
0
"
WD0073
SW7741
Q 11469
1513
EQEQ
6"
2'
-
9
"
B.
O
.
R
E
F
L
E
C
T
I
V
E
S
U
R
F
.
3'
-
3
1
/
4
"
6'
-
3
"
9'
-
0
"
B 18735
6"
Q 11469EQEQ
7
5
4
9'
-
0
"
8 1/2"
Q 11469
9
B 18735
3'
-
4
"
2'
-
9
1
/
2
"
1'
-
5
"
6
10
12
11
6"
2'
-
9
1
/
2
"
9'
-
0
"
B 18735
Q 11469
1'
-
5
"
9
10
6"
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
5
/
2
0
2
4
1
0
:
2
2
:
4
9
A
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I402
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ENLARGED RESTROOM
ACCESSIBILITY PLAN
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
3/8" = 1'-0"1MOUNTING HEIGHTS FOR RESTROOM
ACCESSORIES
6" = 1'-0"2INTEGRAL TILE BASE AT TILED WALL
1/2" = 1'-0"3ENLARGED RESTROOM ACCESSIBILITY PLAN
N
3/8" = 1'-0"4UNISEX CUSTOMER RESTROOM ELEVATION
A
3/8" = 1'-0"5UNISEX CUSTOMER RESTROOM ELEVATION
B
3/8" = 1'-0"6UNISEX CUSTOMER RESTROOM ELEVATION
C
3/8" = 1'-0"7UNISEX CUSTOMER RESTROOM ELEVATION
D
3/8" = 1'-0"8UNISEX PARTNER RESTROOM ELEVATION A
3/8" = 1'-0"9UNISEX PARTNER RESTROOM ELEVATION B
3/8" = 1'-0"10UNISEX PARTNER RESTROOM ELEVATION C
3/8" = 1'-0"11UNISEX PARTNER RESTROOM ELEVATION D
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
A
A
2301 N Tustin Ave
#A8/22/2024
HEAVY-DUTY GRID
NOTES:
1. LIGHT FIXTURES OR DIFFUSERS IN EXCESS
OF 56 LBS REQUIRE (4) 12 GAUGE HANGER
WIRES.
2. SUSPENDED CEILING TO COMPLY WITH
ASCE 7-16 SECTION 13.5.6.2.2., ASTM C636,
CISCA DESIGN REQUIREMENTS
3. CEILINGS SHALL BE SPECIAL INSPECTED
PER SECTION 11A.1.3.9 OF ASCE 7.16
(SEE ADDITIONAL NOTES ON RCP)
(2) 12 GAUGE HANGER
WIRES TO STRUCTURE
ABOVE - AT ALTERNATE
CORNERS OF ALL 2X4
LIGHT FIXTURES AND
HVAC DIFFUSERS
2" OVERSIZED
RING ADAPTER AT
SPRINKLER HEAD
INSTALL COMPRESSION STRUT
EA. DIRECTION OR EVERY 144
S.F. OF CEILING AREA PER CBC
STANDARDS 47-18
12 GA. WIRES @ 12'-0" O.C.
SPLAYED 45° FROM CEILING
PLANE
CROSS RUNNER @ 2'-0" O.C.
45° -
TYP
.
WA
L
L
MAIN RUNNER @ 4'-0" O.C.
NOTE:
1. ALL INTERIOR WALL & CEILING FINISHES SHALL BE FLAME SPREAD CLASS III MIN.
2. SUSPENDED T-BAR SYSTEM SHALL BE 25 GA. MIN.
3. SUSPENDED CEILING TILE SYSTEM TO COMPLY WITH ICC-ESR #1308
4. ALL 24" X 48" LIGHT FIXTURES & 24" X 24" HVAC DIFFUSERS SHALL BE
SUPPORTED BY A MIN. OF (2) HANGERS @ OPPOSITE CORNERS - CEILING
SYSTEM SHALL NOT SUPPORT OTHER ITEMS.
5. CEILING SYSTEM GRID TO BE HEAVY DUTY.
12 GA HANGER WIRE @ 4'-0" O.C.
ALONG EACH MAIN RUNNER
6'-0" MAX.
CEILING SYSTEM GRIDTO
BE HEAVY DUTY.
++
1/2 " =.5 L=5' MAX. x 12"=60
PROVIDE COMPRESSION
STRUTS @ 12'-0" O.C.
EACH DIRECTION (OR 144.
S.F. AND WITH 6'-0" OF
WALLS
60/.5 = 120 < 200
L/R = < 200
NOTE:
'X' CUT BOTTOM OF
CONDUIT (1" DEEP) AND FIT
SNUG TO T-BAR
INTERSECTION
(2) #8 WOOD SCREWS
1" DIA. RIGID CONDUIT
COMPRESSION POST
JOIST, PURLIN OR SUB-PURLIN
(SEE ADDITIONAL NOTES ON RCP)
SUSPENDED CEILING TILE SYSTEM TO COMPLY WITH ICC-ESR #1308
SPLICE AS NEEDED WITH 3/4"
DIA.BY 6" CONDUIT AND #8
MACHINE SCREWS AND NUTS
VA
R
I
E
S
(
V
.
I
.
F
.
)
B
A
HANGER WIRE - PARALLEL TO
WALL @ 4'-0" O.C. - TYP.
MAIN RUNNER - POP RIVET EACH MAIN
RUNNER OR CROSS TEE TO WALL
ANGLE - PROVIDE ADDTIONAL
CLOSURE ANGLES AS REQUIRED
ACCOUSTICAL PANEL - TYP.
MAIN RUNNER - DO NOT ATTACH TO
WALL ANGLE
WALL OR SOFFIT - SEE PLAN
CONTINUOUS 2" X 2" ANGLE WITH #10
SELF-TAPPING SCREWS AT EACH
STUD - TYP.
TYP.
8" MAX.
ATTACHED
(2) ADJACENT WALLS
UNATTACHED
OPPOSITE WALLS
NOTE:
MAIN RUNNERS SHALL BE ATTACHED AT (2) ADJACENT WALLS AS SHOWN IN
CONDITION 'A'
MAIN RUNNERS SHALL BE UNATTACHED AT OPPOSITE WALLS AS SHOWN IN
CONDITION 'B'
SEE ADDITIONAL NOTES ON REFLECTED CEILING PLAN - SHEET I-121
3/4" CLR.
SPREADER BAR AS REQUIRED TO
PREVENT SPREADING
TABLE FOR NON-BEARING METAL STUDS SSMA PRODUCTS
ICC ESR #2054
5 PSI (SIZING PERTAINS TO ALL 'S' WALL TYPES)
STUD SIZE AND GAUGE SPACING MAX. HT.
3625125-18 (3 5/8" X 25 GA.) 16" O.C. 14'-4"
3625125-33 (3 5/8" X 20 GA.) 16" O.C. 16'-5"
3625125-43 (3 5/8" X 18 GA.) 16" O.C. 18'-0"
4005125-18 (4" X 25 GA.) 16" O.C. 15'-4"
4005125-33 (4" X 20 GA.) 16" O.C. 18'-4"
4005125-43 (4" X 18 GA.) 16" O.C. 19'-5"
6005125-18 (6" X 25 GA.) 16" O.C. 19'-9"
6005125-33 (6" X 20 GA.) 16" O.C. 24'-6"
6005125-43 (6" X 18 GA.) 16" O.C. 28'-3"
SEE DETAIL 13 AND 15 THIS SHEET FOR FULL HEIGHT WALLS.
FULL THICKNESS BATT
INSULATION - ONLY WHERE
INDICATED ON PLANS AND
SPECIFICATIONS
FRAMING PER PLAN
FINISH FLOOR1/
4
"
M
A
X
.
5/8" TYPE 'X' GYP. BD.
SHOT PINS - HILTI OR EQUAL
@ 24" O.C.
LARR. #25646 - ESR # 1663
25 GA. FLOOR TRACK -
CONTINUOUS
4X WOOD BLOCKING
BETWEEN ROOF
TRUSSES AS REQUIRED
ROOF FRAMING OR OTHER
STRUCTURAL MEMBER
CONTINUOUS SLIP
TRACK
FRAMING PER PLAN- 1"
MINIMUM CLEAR FROM ROOF
STRUCTURE - TO ALLOW ROOF
DIAPHRAM MOVEMENT - SHOT
PIN - ICC ESR -1752
5/8" TYPE 'X' GYP. BD. - WHERE
OCCURS
DO
N
O
T
A
T
T
A
C
H
G
Y
P
.
B
D
.
AB
O
V
E
T
H
I
S
P
O
I
N
T
(2) #10 X 2" WOOD SCREWS
@ 24" O.C.
SIMPSON TIE HANGER LU
FRAMING ANCHOR @ EA
END. USE (3) 8-d NAILS,
TYP
WEB FILLER WHEN
APPLICABLE
5/8" TYPE 'X' GYP. BD.
ATTACH BRACING TO
CONTINUOUS 20 GA. TOP
TRACK WITH (2) #10 S.M.S.
3 5/8" METAL STUD WALL
BRACING @ 45 DEG. @48" O.C.
IN ALTERNATING DIRECTIONS -
SAME STUD GAUGE AS WALL
FRAMING PER PLAN
I501
7
I501
6
FRAMING PER PLAN
5/8" TYPE 'X' GYP BD.
EXISTING ROOF & STRUCTURE
CONTINUOUS SLIP TRACK
ICC-ESR #2054
LARR # 25631
CEILING PER PLAN
6"
M
I
N
.
5/8" TYPE 'X' GYP
BD. - EXTEND TO
UNDERSIDE OF ROOF
STRUCTURE WHERE
NO CEILING OCCURS
NOTES:
1. ALL INTERIOR WALLS TO HAVE GYPSUM BOARD EXTEND TO PROVIDE TIGHT
BUTT JOINT TO FLOOR SLAB. NO GAP IN EXCESS OF 1/4" WILL BE ALLOWED.
2. PROVIDE WATER RESISTANT GYPSUM BOARD AT THE INTERIORS OF ALL
TOILET ROOMS AND WET WALLS.
3. USE 5/8" TYPE 'X' GYP. BD. THROUGHOUT - U.N.O.
4. PROVIDE SOUND BATT INSULATION AT ALL OFFICE AREAS & RESTROOMS
WALLS
AND CEILINGS.
SIM.
NOTES:
1. ALL INTERIOR WALLS TO HAVE GYPSUM BOARD EXTEND TO PROVIDE TIGHT
BUTT JOINT TO FLOOR SLAB. NO GAP IN EXCESS OF 1/4" WILL BE ALLOWED.
2. PROVIDE WATER RESISTANT GYPSUM BOARD AT THE INTERIORS OF ALL
TOILET ROOMS AND WET WALLS.
3. USE 5/8" TYPE 'X' GYP. BD. THROUGHOUT - U.N.O.
4. PROVIDE SOUND BATT INSULATION AT ALL OFFICE AREAS & RESTROOMS
WALLS
AND CEILINGS.
FRAMING PER PLAN -
ATTACH BRACING TO
CONTINUOUS TOP TRACK
WITH (2) #10 S.M.S.
3 5/8" METAL STUD WALL
BRACING @ 48" O.C. IN
ALTERNATING DIRECTIONS -
GA. TO MATCH WALL
ATTACH BRACING TO
BOTTOM CHORD OR
BLOCKING WITH (2) #10 x 1"
SCREWS
BATT INSULATION AT
UNDERSIDE OF ROOF
DECK AS REQUIRED -
REFER TO T-24 FOR R
VALUE
ADD WEB JOIST STIFFENER
X 12" LONG EACH JOIST
PROVIDE 2X6 BLOCKING AS
REQUIRED AT PARALLEL AND
PERPENDICULAR TRUSS
CONDITIONS WITH LUS26
EACH END TO WEB
STIFFENER
CEILING PER PLAN - REFER
TO I103 FOR CEILING TYPE
AND HEIGHT.
5/8" TYPE 'X' GYP. BD.
6"
M
A
X
.
TYP.45°
ICC-ESR #2054
LARR # 25631
FLOOR FINISH PER PLAN
EXISTING TOP OF SLABI501
6
12
'
-
0
"
M
A
X
.
I501
8
FINISH FLOOR
5/8" TYPE 'X' GYP. BD.
CONTINUES 12" ABOVE
ACOUS.
CEILING
SEE PLAN FOR STUD
SIZE AND TRACK -
ICC-ESR #2054
5/8" WATER RESISTANT GYP.
BOARD
(E) DEMISING WALL
EXISTING CONCRETE SLAB
TYPICAL INTERIOR WALL ASSEMBLY
WALL & CEILING ASSEMBLY NOTES
1. ALL INTERIOR WALLS TO HAVE GYPSUM BOARD EXTEND TO PROVIDE TIGHT
BUTT JOINT TO FLOOR SLAB. NO GAP IN EXCESS OF 1/4" WILL BE ALLOWED.
2. PROVIDE WATER RESISTANT GYPSUM BOARD AT THE INTERIORS OF ALL
TOILET ROOMS.
3. USE 5/8" THICK GYPSUM BOARD THROUGHOUT EITHER TYPE "X" OR UN-RATED
AS NOTED ON SHEET
4. PROVIDE SOUND BATT INSULATION OVER ALL OFFICE AREAS & RESTROOMS.
25 GAUGE FLOOR
TRACK
ANCHOR W/ 5/32" SHOT
PINS AT 36" ON
CENTER
ATTACH BRACING TO
CONTINUOUS TOP TRACK
WITH
(2) #10 S.M.S.
3 5/8" METAL STUD WALL
BRACING AT 45 DEG. SPACED
AT 48" O.C. IN ALTERNATING
DIRECTIONS, SAME STUD
GAUGE AS WALL
PROVIDE 2X6 BLOCKING AS REQUIRED AT PARALLEL AND
PERPENDICULAR TRUSS CONDITIONS W/LUS26 EA. END TO
WEB STIFFENER
ATTACH BRACING TO BOTTOM CHORD OR BLOCKING
WITH (2) #10 x 1" SCREWS
ADD WEB JOIST STIFFENER X 12" LONG EACH JOIST
REFER TO PLAN A101 AND
METAL STUD TABLE - SEE
5/I500
(E) GYP BD
CEILING
I501
6
FINISH FLOOR
5/8" TYPE 'X' GYP. BD.
CONTINUES 12" ABOVE
ACOUS.
CEILING
SEE PLAN FOR STUD
SIZE AND TRACK -
ICC-ESR #2054
5/8" WATER RESISTANT GYP.
BOARD
(E) DEMISING WALL
EXISTING CONCRETE SLAB
TYPICAL INTERIOR WALL ASSEMBLY
WALL & CEILING ASSEMBLY NOTES
1. ALL INTERIOR WALLS TO HAVE GYPSUM BOARD EXTEND TO PROVIDE TIGHT
BUTT JOINT TO FLOOR SLAB. NO GAP IN EXCESS OF 1/4" WILL BE ALLOWED.
2. PROVIDE WATER RESISTANT GYPSUM BOARD AT THE INTERIORS OF ALL
TOILET ROOMS.
3. USE 5/8" THICK GYPSUM BOARD THROUGHOUT EITHER TYPE "X" OR UN-RATED
AS NOTED ON SHEET
4. PROVIDE SOUND BATT INSULATION OVER ALL OFFICE AREAS & RESTROOMS.
25 GAUGE FLOOR
TRACK
ANCHOR W/ 5/32" SHOT
PINS AT 36" ON
CENTER
PROVIDE 2X6 BLOCKING AS REQUIRED AT PARALLEL AND
PERPENDICULAR TRUSS CONDITIONS W/LUS26 EA. END TO
WEB STIFFENER
ATTACH BRACING TO BOTTOM CHORD OR BLOCKING
WITH (2) #10 x 1" SCREWS
ADD WEB JOIST STIFFENER X 12" LONG EACH JOIST
REFER TO PLAN A101 AND
METAL STUD TABLE - SEE
5/I500
(E) GYP BD
CEILING
I501
6
2 PROVIDE 1X NAILER AS NEEDED
5 PROVIDE SEALANT AND BACKER ROD (CONT.)
1
2
3
4
5
5
4 5/8" GWB FINISHED PER SCHEDULES
6
3 STOREFRONT HEAD. USE BLACK ADONIZED MULLION.
7
1 PATCH AND REPAIR STUCCO EXTERIOR PLASTER OVER METAL
LATHE.
6 CONT. VAPOR BARRIER. PATCH AND REPAIR AS NEEDED.
7 EXISTING R-19 BATT INSULATION
8 20GA GALVANIZED DRIP EDGE
8
2 PROVIDE 1X NAILER AS NEEDED
4 5/8" GWB FINISHED PER SCHEDULES
5 PROVIDE SEALANT AND BACKER ROD (CONT.)
1
2
3
4 5
5
3 STOREFRONT JAMB. USE BLACK ANODIZED MULLIONS
6
7
1 PATCH AND REPAIR STUCCO EXTERIOR PLASTER OVER METAL
LATHE.
6 CONT. VAPOR BARRIER. PATCH AND REPAIR AS NEEDED.
7 EXISTING R-19 BATT INSULATION
1
2
3
4
1 PATCH AND REPAIR STUCCO EXTERIOR PLASTER OVER METAL
LATHE.
2 PROVIDE 1X NAILER AS NEEDED
4 5/8" GWB FINISHED PER SCHEDULES
5 PROVIDE SEALANT AND BACKER ROD (CONT.)
3 DRIVE-THRU WINDOW SILL. USE BLACK ADONIZED MULLION.
6 CONT. VAPOR BARRIER. PATCH AND REPAIR AS NEEDED.
5
7 EXISTING R-19 BATT INSULATION
6
7
8 20GA GALVANIZED DRIP EDGE
8
WOOD BLOCKING
BETWEEN ROOF
TRUSSES/JOISTS AS
REQUIRED
ROOF FRAMING OR OTHER
STRUCTURAL MEMBER
SIMPSON TIE HANGER LU
FRAMING ANCHOR @ EA
END. USE (3) 8-d NAILS,
TYP
WEB FILLER WHEN
APPLICABLE
COMPRESSION STRUT
TOP CLIP MECHANICALLY
FASTENED W/(2) #8 WOOD SCREWS
SUSPENDED
CEILING 12GA
HANGING WIRE
MIN. 3" EYE LAG SCREW,
TYP.
SPRING CLIP
3" = 1'-0"1FIXTURE BRACING
12" = 1'-0"2SUSPENDED CEILING DETAIL
12" = 1'-0"4COMPRESSION STRUT
1 1/2" = 1'-0"3T-BAR CEILING
12" = 1'-0"5METAL STUD WALL TABLE
1 1/2" = 1'-0"6BOTTOM TRACK DETAIL
1 1/2" = 1'-0"7TOP TRACK DETAIL
1 1/2" = 1'-0"8TOP TRACK DETAIL
3/8" = 1'-0"9FULL HEIGHT WALL
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
5
/
2
0
2
4
1
0
:
2
2
:
5
1
A
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I501
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
INTERIOR DETAILS
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
3/8" = 1'-0"13TYPICAL INTERIOR WALL3/8" = 1'-0"16TYPICAL INTERIOR FURRED WALL AND
CEILING FRAMING
3/8" = 1'-0"19TYPICAL INTERIOR FURRED WALL AND
CEILING FRAMING - 2 3" = 1'-0"15STOREFRONT HEAD DETAIL
3" = 1'-0"12STOREFRONT JAMB DETAIL
3" = 1'-0"11STOREFRONT SILL DETAIL
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
1 1/2" = 1'-0"20T-BAR HANGING WIRE/ COMPRESSION POST
TO STRUCTURE CONNECTION DETAIL
A
A
A
A
A
A
A
2301 N Tustin Ave
#A8/22/2024
CONT. 3 5/8" MTL
STUD 20GA
(2) #10 SMS @ 24" O.C.(4) #10 SMS @ EA
CONNECTION, TYP.
GYP.BD CEILING HEIGHT
PER SHEET I103
(3) #10 SMS @ EA
CONNECTION, TYP.
3 5/8" 20 GA ALT.
BRACING MTL STUD
@ 48" O.C.
EXISTING
STRUCTURE
ZINTRA ACOUSTICAL
BAFFLES PER SHEET I103
EXISTING STRUCTURE
HEIGHT
GYP.BD CEILING HEIGHT
PER SHEET I103
CONT. 3 5/8" MTL
STUD 20GA
EXISTING STOREFRONT
TO REMAIN
(E) STOREFRONT @
8'-11" AFF(V.I.F)
EXISTING WALL
(3) #10 SMS @ EA
CONNECTION, TYP.
EXISTING ROOF & ROOF
STRUCTURE TO REMAIN
SIMPSON TIE
HANGER
WOOD BLOCKING
12 GA WIRE HANGER
ZINTRA ACOUSTICAL
BAFFLES
(4) #10 SMS @ EA
CONNECTION, TYP.
ALIGN FACE
OF FINISH
(3) #10 SMS @ EA
CONNECTION, TYP.
3 5/8" MTL STUD
20GA @ 16" O.C.
DRYWALL SCREW
(2) #10 SMS @ 16" O.C.
CONTINUOUS LED STRIP LIGHT
(4) #10 SMS @ EA CONNECTION, TYP.
3 5/8" 20 GA MTL TRACK (CONT.)
3 5/8" 20 GA MTL STUD 20GA @ 16" O.C.
6"
3 5/8" MTL STUD 20GA @ 16" O.C.
(4) #10 SMS EA. CONNECTION, TYP.
3 5/8" MTL STUD 20GA @ 16" O.C.
(2) #10 SMS @ EA CONNECTION, TYP.
3 5/8" MTL STUD 20GA @ 16" O.C.
DRYWALL SCREW
(4) #10 SMS @ EA CONNECTION, TYP.
CONT. 3 5/8" MTL STUD 20GA
ZINTRA ACOUSTICAL BAFFLE
ACOUSTICAL BAFFLE TRACK
4"
4"
6"
CONTINUOUS LED STRIP LIGHT
GYP.BD CEILING HEIGHT
PER SHEET I103
GYP.BD CEILING HEIGHT
PER SHEET I103
ZINTRA ACOUSTICAL
BAFFLES PER SHEET I103
12 GA WIRE HANGER, TYP.
CONT. 6" MTL STUD 20GA
ALTERNATING
BRACING STUD 3 5/8"
20GA @ 48" O.C.
TYP.
6FT MAX SPAN 6FT MAX SPAN
(3) #10 SMS @ EA CONNECTION, TYP.
SIMPSON TIE HANGER LU
FRAMING ANCHOR @EA END.
USE (3) 8-D NAILS, TYP.
6" MTL STUD 20GA @ 16" O.C.
6" MTL STUD 20GA @ 16" O.C.
CONT. 3 5/8" MTL STUD 20GA
4X WOOD BLOCKING, TYP.
I501
7
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
8
/
2
0
2
4
2
:
4
0
:
2
1
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I501A
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
INTERIOR DETAILS
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
1 1/2" = 1'-0"3SOFFIT FRAMING DETAIL B
NOT USED
NOT USED
NOT USED
NOT USED
1 1/2" = 1'-0"1SOFFIT FRAMING DETAIL A
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
A
A
A
A
2301 N Tustin Ave
#A8/22/2024
4 1/2"4' - 0 1/2"4' - 0 1/2"4 1/2"
8"
ARMSTRONG 15/16" T
GRID 360 POLYBAKED
BLACK 48"X48" GRID
PATTERN, UNO
AIRCRAFT STEEL
CABLES (TYP.)
8" ZINTRA FELT BAFFLES
TWO 8'-10" AND ONE 3'-1"
EXISTING ROOF
JOIST VIF
I501B
15
Sim
I501B
16
Sim
ARMSTRONG 15/16" T
GRID 360 POLYBAKED
BLACK 48"X48" GRID
PATTERN, UNO
AIRCRAFT STEEL
CABLES (TYP.)
BAFFLES SLOT
ON TO GRID
EXISTING ROOF
JOIST VIF
10'-6 1/2" AFF
B/O BAFFLES1' - 0"
TYP.
8"
(
T
Y
P
.
)
1
1
/
2
"
6
1
/
2
"
8" ZINTRA FELT BAFFLES
TWO 8'-10" AND ONE 3'-1"
(TYP.)
EQ 1"EQ
ARMSTRONG 15/16" T
GRID 360 POLYBAKED
BLACK 48"X48" GRID
PATTERN, UNO
AIRCRAFT STEEL
CABLES (TYP.)
BAFFLES SLOT
ON TO GRID
8" ZINTRA FELT BAFFLES
TWO 8'-10" AND ONE 3'-1"
(TYP.)
8"
(
B
A
F
F
L
E
S
T
Y
P
.
)
I501B
16
Sim
ARMSTRONG 15/16" T
GRID 360 POLYBAKED
BLACK 48"X48" GRID
PATTERN, UNO
AIRCRAFT STEEL
CABLES (TYP.)
BAFFLES SLOT
ON TO GRID
8" ZINTRA FELT
BAFFLES TWO
8'-10" AND ONE
3'-1" (TYP.)
1"1/2"
(TYP.)
1 1/2"
0'
-
1
1
/
2
"
(T
Y
P
.
)
0'
-
0
1
/
4
"
SUPPORT GRID
4 1/2"
SUPPORT GRID
4' - 0 1/2"
SUPPORT GRID
4' - 0 1/2"
SUPPORT GRID
9"
SUPPORT GRID
1' - 7"
SUPPORT GRID
9"
SUPPORT GRID
4' - 0 1/2"
SUPPORT GRID
4' - 0 1/2"
SUPPORT GRID
4 1/2"
SU
P
P
O
R
T
G
R
I
D
5"
SU
P
P
O
R
T
G
R
I
D
3'
-
0
"
SU
P
P
O
R
T
G
R
I
D
1'
-
7
"
SU
P
P
O
R
T
G
R
I
D
3'
-
0
"
SU
P
P
O
R
T
G
R
I
D
1'
-
7
"
SU
P
P
O
R
T
G
R
I
D
3'
-
0
"
SU
P
P
O
R
T
G
R
I
D
7"
ARMSTRONG
15/16" DRID 360
POLYBAKED
TRAVERTINE
DARK, (TYP.)
13
I501B
Sim
14
I501B
Sim
I501
2
Sim
LATERAL
BRACING
LATERAL
BRACING
LATERAL
BRACING
LATERAL
BRACING
LATERAL
BRACING
LATERAL
BRACING
TYP.
BAFFLE LENGHT
8' - 10"
BAFFLE LENGHT
2' - 4"
BAFFLE LENGHT
8' - 10"
TY
P
.
S
P
A
C
I
N
G
8
1
/
2
"
1'
-
9
"
1'
-
9
"
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
8
/
2
0
2
4
2
:
4
0
:
2
3
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I501B
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
INTERIOR DETAILS
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
3/4" = 1'-0"13ZINTRA BAFFLES CROSS SECTION A
3/4" = 1'-0"14ZINTRA BAFFLES CROSS SECTION B
3" = 1'-0"15ENLAGED BAFFLES SEAM DETAIL
3" = 1'-0"20FELT PANEL - CONNECTION 3" = 1'-0"16BAFFLES TO GRID INTERLOCKING
1/2" = 1'-0"2ZINTRA BAFFLES T-GRID PLAN
1/2" = 1'-0"1ENLARGED ZINTRA BAFFLES PLAN
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
A A
A
A
A
A
2301 N Tustin Ave
#A8/22/2024
(2) 3 5/8 MTL
STUDS WITH 5/8"
GYP. BD. EACH
SIDE - TYP.
WATER HEATER
(700 LB MAX)
R.O. STORAGE
TANK
(350 LB MAX)
(2) 1/2" PLYWOOD
FLOOR OR 1/2"
GLASSCRETE CEMENT
BOARD
(2) 6" X 16 GA. MTL JOISTS WITH 4 1/2" X
12 PANHEAD SCREWS WITH
WASHERS - ALIGN JOIST WITH WATER
HEATER "FEET"
PLAN VIEW
1 1/2" W X 16 GA
STRAP. ATTACH TO
THE CFS STUD WALL
W/ (2) #14 SCREWS
EACH END.
A A 362S162-54 MIL
STUDS, ALIGNED
WITH STRAP
362S162-54 MIL
STUDS, ALIGNED
WITH STRAP
(2) 6" 18 GA. BACK-BACK JOIST
@ 16" O.C. (600S137-43, 50KSI)
W/ (2) ROWS #10 X 1" SCREWS
AT 4" O.C. MAX.
NEW WATER RESISTANT GYP.
BOARD TO BE FINISHED WITH
FRP
NEW WALL PER SHEET A101
DETAIL A-A
STOP GYP BOARD WHERE
JOIST MEETS STUD WALL.
STOP GYP BOARD WHERE
JOIST MEETS STUD WALL.
XXXT125-XX BLOCKING TO
MATCH WALL DEPTH AND GA.
W/ (2) #10 X 1/2" SCREWS AT
STUDS.
XXXT125-XX BLOCKING TO
MATCH WALL DEPTH AND GA.
W/ (2) #10 X 1/2" SCREWS AT
STUDS.
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
8
/
2
0
2
4
2
:
4
0
:
2
3
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I501C
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
INTERIOR DETAILS
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
NOT USEDNOT USED
NOT USEDNOT USEDNOT USED
NOT USEDNOT USEDNOT USED
NOT USEDNOT USED
NOT USEDNOT USED
1/2" = 1'-0"1WATER HEATER & RO PLATFORM DETAIL
NOT USED NOT USED NOT USED
NOT USED
A A
2301 N Tustin Ave
#A8/22/2024
10"X10" (250MM X 250MM) BACKER BOARDS.
ATTACH TO PLYWOOD SUBSTRATE WITH
SILICONE ADHESIVE AND WOOD SCREWS.
SILICONE PERIMETER.
INTERIOR FACE OF DIEWALL
FINISHED FLOOR
PUMP ATTACHED TO BACKER BOARD
WITH ASSEMBLY COMPONENTS
SEE NOTES ABOVE FOR
ASSEMBLY ITEMS
NOTES:
1. LOCATE PUMP WITHIN CORD LENGTH LIMIT. ORIENT WITH
PUMP HEAD LEFT, RIGHT AND AT BOTTOM. LOOSEN PUMP
HEAD CLAMP, ROTATE AND RE-TIGHTEN AS REQUIRED PER
ORIENTATION TO PROVIDE FRONT ACCESS TO FLOW.
ADJUSTMENT WITHIN CORD LENGTH LIMIT.
2. USE LOCKTITE ON ISOLATOR THREADS. DO NOT OVER
TIGHTEN.
3. LOOSEN PUMP HEAD CLAMP, ROTATE AND RE-TIGHTEN AS
REQUIRED FOR PUMP ORIENTATION.
4. BACKER BOARD'S ASSEMBLY COMPONENTS INCLUDE:
(1) BACKER BOARDS
(4) TENETS, 1/4-20 VENDOR MOUNTED
(8) WOOD SCREWS #8 1-1/4" (32MM)
(4) NEOPRENE ISOLATORS, KARMAN RUBBER, K84-60
NEOPRENE
(4) LOCK NUTS, 1/4-20 NYLON
(4) WASHERS, 1/4" (7MM) FLAT
MI
N
.
6"
(
1
5
2
M
M
)
DO NOT BLOCK GROMMET OPENING.
CUT ANGLE AS REQUIRED TO MAINTAIN
MIN. 1/2" (13MM) CLEAR AROUND OPENING.
MECHANICALLY FASTEN
COUNTER-SUNK
CORROSION RESISTANT
FASTENERS AT 6"(150MM)
O.C. WITH 3/4" (19MM)
EMBEDMENT.
MECHANICALLY FASTEN ANGLE TO
COUNTERTOP SUBSTRATE OR EPOXY
FASTEN ITO COUNTERTOP.1 1/2" X 1 1/2" (38MM X 38MM)
CORROSION RESISTANT
STEEL ANGLE
UNDERCOUNTER
REFRIGERATOR
.
1/2" (13MM) PREFERRED
OFFSET DISTANCE FROM
EDGE OF COUNTERTOP
COUNTERTOP DEPTH MAY VARY
COUNTERTOP
ABOVE
UNDERCOUNTER
REFRIGERATOR
STEEL ANGLE
CENTERED ON
REFRIGERATOR
EQ
.
EQ
.
FRONT EDGE OF COUNTERTOP TO FACE OF ANGLE
2' - 5" (737MM)
SECTION VIEW PLAN VIEW
NOTES
1. 24" (610MM) 1 1/2" X 1 1/2" (38MM X 38MM) STEEL ANGLE TO BE USED WITH SINGLE DOOR REFRIGERATORS.
2. 48" (1220MM) 1 1/2" X 1 1/2" (38MM X 38MM) STEEL ANGLE TO BE USED WITH DOUBLE DOOR REFRIGERATORS.
SE
E
N
O
T
E
S
B
E
L
O
W
FRONT EDGE OF
COUNTERTOP
ABOVE
.3
/
4
"
6"
VERIFY IN-WALL BLOCKING OR
ENSURE SOLID ATTACHMENT OF
CLEAT TO WALL AT EACH STUD
CENTER FASTENERS VERTICALLY
ON WALL CLEAT SOLIDLY
ATTACHED TO WALL. SEE
SCHEDULE "WALL TYPE
FASTENER SCHEDULE" FOR
SPECIFICATIONS.
1"X4" (25MM X 100MM)
FURRING STRIP OR EQUIVALENT
STUD WALL BLOCKING REQUIREMENTS:
WOOD STUD WALLS REQUIRE MIN. 2" X 6"
(50MM X 150MM) WOOD BLOCKING SECURED
FLUSH TO STUD FACE WITH (3) 10D NAILS (OR
EQUIVALENT)
METAL STUD WALLS REQUIRE MIN. 2" X 6"
(50MM X 150MM) WOOD BLOCKING SECURED
FLUSH TO STUD FACE WITH MIN. (3) #6 CT.
1.25" (30MM) SCREWS (OR EQUIVALENT)
EQ EQ EQ EQ EQ EQ EQ
VARIES
WALL TYPE FASTENER SCHEDULE
WALL TYPE WALL BLOCKING FASTENERS NOTES
WOOD FRAME #8 X3" (75MM) WD
OR EQUIVALENTX REFER TO BLOCKING REQUIREMENTS
METAL FRAME X #6 CT. X 1 1/4" (30MM) MTL/WD
OR EQUIVALENT
MIN. 5/16" X 3" (8MM X 75MM)
TAPCON OR EQUIVALENT
MIN. 1/4" X 3" (7MM X 75MM)
SLEEVE ANCHOR OR EQUIVALENT
MIN. 1/4" X 1" (7MM X 25MM)
WEDGE ANCHOR OR EQUIVALENT
SPACE PER DETAIL THIS SHEET
SPACE PER DETAIL THIS SHEET
AVOID SETTING ANCHORS IN MORTAR JOINTS
SPACE PER DETAIL THIS SHEET
(6) FASTENERS EVENLY SPACED 3" (75MM)
MINIMUM. ACROSS OPENING (TYPICAL AT ALL
CABINETS)
CENTER FASTENERS VERTICALLY ON WALL CLEAT
SOLIDLY ATTACHED TO WALL. SEE "WALL TYPE
FASTENER SCHEDULE" FOR SPECIFICATION.
ADJUSTABLE SHELF (IF APPLICABLE)
METAL TRIM TO BE PAINTED
SIMILAR FASTENERS AT EACH STUD LOCATION
ACROSS OPENING (TYPICAL AT ALL CABINETS)
CMU
CONCRETE
BRICK
REFER TO BLOCKING REQUIREMENTS
34" MAX. AFF
METAL ANGLE,
TYP.
COUNTERTOP
SUBSTRATE
ALUM. Z-CLIPS, TYP.
FINISH PANEL
DIEWALL
COUNTERTOP
LED STRIP LIGHTING
VARIES
MI
N
.
1/
2
"
4" (TYP.)
NOTE:
ALL COMPONENTS
FURNISHED BY
OTHERS AND
INSTALLED BY G.C.
UNLESS NOTED
OTHERWISE.
2
1
/
4
"
FINISH PANEL
METAL ANGLE TRIM
ATTACHED AT BACK OF
PANEL WITH COUNTER
SUNK FASTENER
GAP FOR Z-CLIP
ATTACHMENT - TYP. OR
BLOCKING FOR DIRECT
MOUNT TO DIEWALL
TY
P
.
1/
4
"
STEEL FLAT BAR
TRIM AT BOTTOM
AND TOP OF
PANELS, TYP.
ENCAPSULATE DIE
WALL ENDS WITH
PVC TO MATCH
STORE SPECIFIC
LAMINATE
DIEWALL TYP.
OR CABINET
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
4
6
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I502
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
CASEWORK DETAILS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
Revision Schedule
Rev Date By Description
1 1/2" = 1'-0"1ESPRESSO PUMP MOUNTED AT DIE WALL
1 1/2" = 1'-0"3UNDERCOUNTER REFRIGERATOR STOP INSTALLATION
1" = 1'-0"5UPPER CABINET ATTACHMENT
6" = 1'-0"15FINISH PANEL - BUILT-UP COUNTERTOP OVERHANG
12" = 1'-0"6TYPICAL DETAIL AT FINISH PANEL END - VERTICAL METAL TRIM
NOT USEDNOT USED
NOT USEDNOT USED
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
CORIAN SHROUD
COVE DETAIL ON
THIS SIDE ONLY
'U' SHAPED ALUMINUM
GLAZING SEAT SECURE
TO BLOCKING BELOW
BLOCKING
MIN. 1/16" GAP AT GLASS FILLED WITH
CLEAR SILICONE, BOTH SIDES, TYP.
VERIFY MIN. GLASS HEIGHT WITH LOCAL CODES
34" MAX. A.F.F.
1 1/2"
3/8" TEMPERED
GLASS
6"
4"
NOTE:
ALL COMPONENTS
FURNISHED BY
OTHERS AND
INSTALLED BY G.C.
UNLESS NOTED
OTHERWISE.
ESPRESSO CAP CORIAN COUNTERTOP
METAL BOTTOM TRIM
PER DETAILS
METAL CORNER TRIM
PER DETAILS
HARDWOOD SLATS
1/2" PLYWOOD BACKER (TYP.)
HARDWOOD SLATS
SECURED TO
SUBSTRATE /
STRUCTURE PER
MANUFACTURER'S
RECOMMENDATIONS CUSTOMER
FACING SIDE
INTERIOR SIDE
ELEVATION
.3/
8
"
...2 5/8" 1/8" 2 1/4"
.3/
1
6
"
.
3/
1
6
"
20 STAVES, NO BUTT JOINTS
3' - 11 3/4"
3' - 11 1/2" BACKER
2'
-
3
"
A
NOT TO SCALE
ENLARGED SECTION PROFILEA
DIRECTION OF GRAIN.
TYP. ALL SLATS.
INTERIOR SIDE TO BE SECURED TO
SUBSTRATE / STRUCTURE PER DETAILS
2'
-
6
"
M
I
N
.
2'
-
8
"
2'
-
0
"
2'
-
1
0
"
10
'
-
0
"
M
I
N
.
C
E
I
L
I
N
G
H
E
I
G
H
T
PROVIDE SPLIT ESCUTCHEON PLATE
AT WALL PENETRATION
DOOR FACE W/ TAPERED EDGE
PULL
MOUNTING TEMPLATE, BLACK
IN-WALL BLOCKING REQUIRED,
PROVIDED BY G.C.
FRAMING, BEYOND
LIGHTING COVE
DOOR FACE W/
TAPERED EDGE
PULL
MOUNTING
TEMPLATE, BLACK
IN-WALL BLOCKING
REQUIRED,
PROVIDED BY G.C.
DOOR FACE W/
TAPERED EDGE
PULL
MOUNTING
TEMPLATE, BLACK
IN-WALL BLOCKING
REQUIRED,
PROVIDED BY G.C.
SECTION A - FUTURE DISPENSESECTION B - CUP LABELER
BA
FRAMING, BLACK
LIGHTING COVE
SECTION C - NUGGET ICE DISPENSESECTION D - DMB
D C
CL
E
A
R
18
"
M
I
N
.
ACCESS DOOR
CEILING
SOFFITUNDER SOFFIT
LIGHTING
UNDER CABINET
STRIP LIGHTING
UNDER CABINET
STRIP LIGHTING
UNDER CABINET
STRIP LIGHTING
ELEVATION
DMB
EQ
EQ
NOTE:
• CEILING HEIGHT 10'-0" MIN.
1. NUGGET ICE RIDE SYSTEM TO RUN IN
STANDARD SOFFIT
2. DMB TO BE MOUNTED ON FACE OF SOFFIT
• ACCESS PANEL TO BE SIZED TO AVOID
CONFLICT WITH LIGHTING COVE
• PROVIDE CONTINUOUS FLOOR TO CEILING
BLOCKING FOR THE ENTIRE LENGTH OF THE
STATION
1'
-
2
"
3'
-
1
0
"
FRP TO FINISH INTERIOR OF SOFFIT.
FRP ON BACK WALL EXTENDS TO
BOTTOM OF UPPER CABINET (ABOVE
ICE DISPENSE ONLY)
OPENING IN SOFFIT TO ACCESS
EQUIP. BELOW
1" MIN.
24" MIN.
18
"
M
I
N
.
EXTEND FULL HEIGHT
BLOCKING 8" MIN. BEYOND
STATION . TERMINATE AT
OH SOFFIT
4' - 7"
CLEAR
18" MIN.
ACCESS DOOR
NOTES:
CABINETS TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS
2'
-
1
0
"
2'
-
2
"
ELECTRICAL
OUTLET
2X6
SUPPORT
W/SHIM
COVED BASE
PER SHEET
I104
2'-10" AFF
(BACKBAR
COUNTERTOP)
COUNTERTOP WITH
INTEGRAL BACKSPLASH
1/4" GREEN BOARD TILE
SUBSTRATE BY GC
BACKBAR WALL TILE
BETWEEN TOP OF
BACKSPLASH AND CEILING
ABOVE - SEE INTERIOR
ELEVATIONS
1 1'-7" AFF (CW SUPPLY)
2 1'-6" AFF (CWF SUPPLY)
3 1'-5" AFF (HW SUPPLY)
4 VARIES: 1/4" PER FT. FALL (ABS 2" WASTE LINE)
5 APPLY FRP TO WALL BEHIND CABINETS -SEE I105 WALL FINISH
PLAN.
5"
* 45 LBS DEAD LOAD FOR LIQUID STORAGE OVER AND ABOVE THE CASEWORK ITSELF.
* A LIVE LOAD OF A PARTNER EITHER PULLING AND OR CLIMBING ON THE CASEWORK.
* SEISMIC ACCELERATION CONDITIONS AT THE SITE.
1
2
3
4
5
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
5
/
2
0
2
4
1
0
:
2
2
:
5
6
A
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I502A
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
CASEWORK DETAILS
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
6" = 1'-0"1ESP SHROUD - CORIAN WITH SNEEZE GUARD3/4" = 1'-0"9FINISH APPLICATION (MAD 101-V) SLAT W/ REVEAL
3/4" = 1'-0"3UPPER CABINET -CEILING HEIGHT GREATER THAN 10'-0" -WITH SOFFIT
1" = 1'-0"17WALL SECTION @ BACKBAR (SHELVING)
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
A
2301 N Tustin Ave
#A8/22/2024
FOR OPENING SIZE/ SHAPE
VARIES. SEE PLAN VIEW
13 mm
1/2"
FULLY ENCAPSULATED
MOISTURE RESISTANT
SUBSTRATE
COMMERCIAL
GRADE SILICONE AT
EXPANSION JOINT 3 mm
1/8"
32
m
m
1
1
/
4
"
12
7
m
m
VE
R
I
F
Y
H
T
.
P
E
R
C
O
N
S
T
R
U
C
T
I
O
N
D
R
A
W
I
N
G
S
MI
N
.
5
"
10 mmr 3/8"
3 mmr 1/8"
25 mm
1"
STANDARD GROMMET HOLE
4" / 75 mm TYP.
51 mm
2" TYP.
3 mm
1/8"
13 mm
1/2"
15
2
m
m
6"
1/2" (13mm) X
1/2" SCRIBE
WALL
FULLY ENCAPSULATED
MOISTURE RESISTANT
SUBSTRATE
COMMERCIAL
GRADE SILICONE
AT EXPANSION
JOINT
GROMMET INSERT
SHOWN DASHED
12
7
m
m
VE
R
I
F
Y
H
T
.
P
E
R
C
O
N
S
T
R
U
C
T
I
O
N
D
R
A
W
I
N
G
S
MI
N
.
5
"
3 mmr 1/8"
FULLY ENCAPSULATED
MOISTURE RESISTANT
SUBSTRATE
25 mm
1"
1/2" (13mm) X
1/2" SCRIBE
WALL
RAISED GROMMET HOLE
4" / 75 mm TYP.
51 mm
2" TYP.
COMMERCIAL
GRADE SILICONE AT
EXPANSION JOINT
15
2
m
m
6"GROMMET INSERT
SHOWN DASHED
32
m
m
1
1
/
4
"
13
m
m
1/
2
"
32 mm
TO C.L.
1 1/4"
3 mmr 1/8"
FULLY ENCAPSULATED
MOISTURE RESISTANT
SUBSTRATE
COMMERCIAL
GRADE
SILICONE
DRIP CHANNEL IF NEEDED
PER WORKSTATION
13 mm
1/2"3 mm
1/8"
6 mmr 1/4"
5
m
m
3/
1
6
"
EQUIPMENT INSERT
VARIES PER
13 mm
1/2"
FULLY ENCAPSULATED MOISTURE
RESISTANT SUBSTRATE
COMMERCIAL
GRADE SILICONE AT
EXPANSION JOINT
3 mm
1/8"
41
m
m
1
5
/
8
"
3
m
m
1/
8
"
2 mmr 1/8"
13 mm
1/2"
COMMERCIAL
GRADE
SILICONE AT
FIXTURE AND
COUNTERTOP
CONNECTION
-TYP.
FULLY ENCAPSULATED
MOISTURE RESISTANT
SUBSTRATE
PER EQUIP.
VARIES
10
m
m
3/
8
"
3
m
m
1/
8
"
COMMERCIAL
GRADE SILICONE AT
EXPANSION JOINT
10 mm
R 3/8"
41
m
m
1
5
/
8
"
3 mm
1/8"
EQUIPMENT INSERT
VARIES PER
13 mm
1/2"
3 mm
TYP.
1/8" MAX.
COMMERCIAL
GRADE SILICONE
AT FIXTURE AND
COUNTERTOP
CONNECTION -TYP.
1 1/2" MIN.
PER SHOP DRAWINGS
TYP. LENGTH BY MFR.3 mm
TYP.
1/8"
COMMERCIAL GRADE
SILICONE AT EXPANSION
JOINT
1/2" CORIAN - TYP
FULLY ENCAPSULATED MOISTURE
RESISTANT SUBSTRATE
REINFORCEMENT
STRIP - CORIAN
R .25"
0.19" DEEP
FULLY ENCAPSULATED MOISTURE
RESISTANT SUBSTRATE
COMMERCIAL GRADE SILICONE
AT EXPANSION JOINT
DRIP CHANNEL
6 mm
1/4"
r 1/4"
12 mm
1/2"
25 mm
1"
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
4
8
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I502B
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
CASEWORK DETAILS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
Revision Schedule
Rev Date By Description
12" = 1'-0"1CORIAN COUNTERTOP TYP. CUTOUT AT TRASH AND GROMMET
12" = 1'-0"3CORIAN COUNTERTOP BACKSPLASH AND GROMMET12" = 1'-0"11CORIAN COUNTERTOP BACKSPLASH AND COVED GROMMET
12" = 1'-0"2CORIAN COUNTERTOP FRONT EDGE
12" = 1'-0"9CORIAN COUNTERTOP TYP. ICE BIN CUTOUT WITH W/ SQUARED EDGE
12" = 1'-0"10CORIAN COUNTERTOP TYP. SINK CUTOUT W/ COVED EDGE
12" = 1'-0"17CORIAN COUNTERTOP REINFORCEMENT
STRIP AT HARD SEAM
12" = 1'-0"18CORIAN COUNTERTOP FRONT EDGE AT ICE
BIN
NOT USED
NOT USED
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
STL. FLAT BAR VERTICAL TRIM
AT PLANK END TO FORM
MITERED CORNER DETAIL
GAP FOR Z-CLIP
ATTACHMENT - TYP. OR
BLOCKING FOR DIRECT
MOUNT TO DIEWALL
DIEWALL - TYP., OR
CABINET
FASTEN MTL. TRIM TO FINISH
PANEL FROM SIDE WITH
COUNTER SUNK FASTENER
FINISH PANEL
TYP.
1/4"
A-A
ELEVATION
VIEW
A-A SECTION
VIEW
EQ
EQ
1'
-
4
"
1'
-
4
"
TOP OF
MERCHANDISE DISPLAY FIXTURE
5'-11 1/2" (1816MM) A.F.F.
(VERIFY IN FIELD)
"L" BRACKET PROVIDED BY
MANUFACTURER TO BE SECURED
TO TOP OF MERCHANDISE DISPLAY
USE #8 SCREW (MIN. 1 1/2" (40MM
EMBEDMENT) TO SECURE BRACKET
TO BLOCKING
MERCHANDISE DISPLAY FIXTURE
3/4" (20MM) BLOCKING LOCATED
BEHIND SUBSTRATE. EXTEND
8" (205MM) MIN. BEYOND "L"
BRACKET ON ALL SIDES.
8"VARIES 8"
WALL FINISH PER SCHEDULE
1' - 9 1/2"4' - 2 3/4"4' - 2 3/4"1' - 8 3/4"
1'
-
9
1
/
2
"
4'
-
2
3
/
4
"
4'
-
2
3
/
4
"
1'
-
8
3
/
4
"
I502C
14
13
CTK0001CTK0001CTKX001
CTK0001
CTK0001
F-0243F-0243F-0243
F-0243
F-0243
r 1' - 8 3/4"
r 1' - 8 3/4"
1' - 4 1/2"8"1' - 4 1/4"8"3' - 6 3/4"8"2' - 4 1/4"8"5"
5' - 8 1/2"3"3' - 11 3/4"3"1' - 6 1/4"
1' - 4 3/4"2"1' - 11 1/2"2"1' - 11 1/2"2"1' - 11 1/2"2"1' - 11 1/2"2"1' - 6 1/4"
2"
9
1
/
2
"
3
1
/
4
"
ø 4 3/4"
1'
-
4
"
2'
-
2
1
/
4
"
1"
MT0028
TYP.
WD0073
F-0243F-0243
1' - 4 1/2"2"1' - 11 1/2"2"1' - 11 1/2"2"1' - 11 1/2"2"1' - 11 1/2"2"1' - 6 1/4"
4 1/2"8"2' - 5"8"3' - 6 3/4"8"1' - 4 1/4"8"1' - 4 1/2"
1' - 6 1/2"3"3' - 11 3/4"3"5' - 8 1/2"
1'
-
4
"
1"
2'
-
2
1
/
4
"
ø 4 3/4"
2"
9
1
/
2
"
3
1
/
4
"
MT0028
TYP.
F-0243F-0243
WD0073
1" MT0029 STEEL ANGLE
TOP & BOTTOM TO CAP
WOOD CLADDING
CEILING
WALL AS SCHEDULED
PROVIDE BLOCKING AS
REQUIRED
1/
8
"
WOOD CLADDING AS
SCHEDULED
PAINT
BLACK
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
4
9
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I502C
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
CASEWORK DETAILS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
Revision Schedule
Rev Date By Description
12" = 1'-0"1MITER DETAIL AT VERTICAL CORNER TRIM
3/4" = 1'-0"3MERCHANDISE WALL BAY DISPLAY FIXTURE WALL ATTACHMENT
NOT USED
3/4" = 1'-0"11ENLARGED BANQUETTE
3/4" = 1'-0"14BANQUETTE ELEVATION A
3/4" = 1'-0"13BANQUETTE ELEVATION B 6" = 1'-0"9CLADDING TOP DETAIL
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
6" (150MM) +/- TYP. A.F.F.
CONTINUOUS
WATERPROOF MEMBRANE.
EXTEND 6" (150mm) UP BASE
COVED TILE BASE PER
SCHEDULE. ADHERE TO
TOE KICK BASE PER MFR'S
RECOMMENDATIONS.
3/8" (6MM) RADIUS AT
COVED BASE
FINISH FLOOR PER
SCHEDULE
CONTINUOUS WATERPROOF
MEMBRANE APPLIED TO SUBFLOOR.
EXTEND EDGE TO 12" (305mm)
OFFSET FROM CABINET BASE.
CONCRETE SLAB
SEALANT TO MATCH
ADJACENT WALL FINISH
COVED TILE BASE PER
SCHEDULE. ADHERE TO
WALL PER MFR'S
RECOMMENDATIONS.
3/8" (6MM) RADIUS AT
COVED BASE
FINISH FLOOR PER
SCHEDULE
CONCRETE SLAB
WALL TYPE PER LEGEND
STOREFRONT DOOR
WITH THRESHOLD
WALK-OFF MAT PER
SCHEDULE
STAINLESS STEEL
ANGLE
TILE FLOOR PER
SCHEDULE
PER TILE
MFR.
WATERPROOF MEMBRANE
ON WOOD SUBFLOOR ONLY
.
ECO-GRIP BASE
CAP. COLOR TO
MATCH ECO-GRIP
FLOORING
ECO-GRIP
EPOXY
ADHESIVE
ECO-GRIP
SEALANT
ECO-GRIP
FLOORING
3/8" (6MM)
ROUTED
COVE
STAINLESS STAPLE
OR POWDER COATED
FASTENER
FRP WALL
COVERINGWALL AND
SHEATHING
PER PLAN
CONCRETE
SLAB
ECO-GRIP FLOORING
ECO-GRIP EPOXY
ADHESIVE
16 GA. 2 1/4" (57MM)
WIDE STAINLESS STEEL
TRANSITION STRIP
TILE FLOOR
PER PLAN
SUBSTRATE MAY REQUIRE
SLOPING TO ADJUST HEIGHT
SO THAT ECO-GRIP AND
ADJACENT FLOOR ARE FLUSH
STAINLESS
FASTENER
LEAD ANCHOR
ECO-GRIP
SEALANT
ROUTE OUT
FLOORING TO DEPTH
OF TRANSITION STRIPCONCRETE
SLAB
SEALANT
SLOPE
2% MAX
ECO-GRIP
FLOORING
ECO-GRIP
SEALANT
ECO-GRIP BASE
CAP. COLOR TO
MATCH ECO-GRIP
FLOORING
STAINLESS STAPLE
OR POWDER COATED
FASTENER
CABINET FINISH
FACE
INSTALL CASEWORK
BASE PRIOR TO
ECO-GRIP FLOORING
ECO-GRIP
EPOXY
ADHESIVE
3/8" (6MM)
ROUTED
COVE
CONCRETE SLAB
6"
(
1
5
0
M
M
)
M
I
N
.
ECO-GRIP
FLOORINGECO-GRIP
EPOXY
ADHESIVE 3/8" (6MM)
ROUTED COVE
INSTALL CASEWORK BASE PRIOR
TO ECO-GRIP FLOORING
6" (150MM) +/- TYP. A.F.F.
CABINET TOE-KICK OVERHANG
CONCRETE SLAB
ECO-GRIP BASE CAP. COLOR TO
MATCH ECO-GRIP FLOORING
STAINLESS STAPLE OR POWDER
COATED FASTENER
ECO-GRIP
SEALANT
ECO-GRIP
FLOORING
ECO-GRIP
SEALANT
ECO-GRIP BASE CAP.
COLOR TO MATCH
ECO-GRIP FLOORING
STAINLESS STAPLE
OR POWDER COATED
STEEL FASTENER
BAR DIEWALL
INSTALL CASEWORK
DIEWALL PRIOR TO
ECO-GRIP FLOORING
ECO-GRIP EPOXY
ADHESIVE
3/8" (6MM)
ROUTED
COVE
BASE AND
FLOORING PER
SCHEDULE
BAR FINISH
PANEL
CONCRETE SLAB
6"
(
1
5
0
M
M
)
M
I
N
.
CAFE BAR
CONCRETE
SLAB
FLOOR SINK
HALF GRATE
STAINLESS STEEL
MEMBRANE CLAMP
ECO-GRIP EPOXY
ADHESIVE
ECO-GRIP
FLOORING
STAINLESS STEEL
SEDIMENT BUCKET WITH
LASER PERFORATIONS
ECO-GRIP BASE CAP.
COLOR TO MATCH ECO-
GRIP FLOORING
ECO-GRIP
EPOXY
ADHESIVE
ECO-GRIP SEALANT
ECO-GRIP
FLOORING
3/8" ROUTED COVE
STAINLESS STAPLE OR
POWDER COATED FASTENER
FRP WALL
COVERING
CONCRETE
CURB
10
"
6"
ECO-GRIP
FLOORING
3/8"
ROUTED
COVE
WALL TILE PER SCHEDULE
CLEAR SEALANT
STAINLESS STEEL
BACKSPLASH
CEMENTITOUS BACKER
BOARD
WALL TYPE PER LEGEND
SCHLUTER-JOLLY EMBEDDED
IN GROUT
WALL TILE PER SCHEDULE
CLEAR SEALANT
SOLID SURFACE
BACKSPLASH
CEMENTITOUS BACKER
BOARD
HEIGHT PER PLAN
WALL TYPE PER LEGEND
SCHLUTER-JOLLY EMBEDDED
IN GROUT
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
5
/
2
0
2
4
1
0
:
2
2
:
5
9
A
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I503
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
FLOOR AND WALL
FINISH DETAILS
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
6" = 1'-0"17INTEGRAL TILE BASE AT CABINET
6" = 1'-0"8INTEGRAL TILE BASE AT WALL
6" = 1'-0"14TRANSITION - TILE TO WALK OFF MAT 6" = 1'-0"2ECO-GRIP BASE CAP WITH FRP
12" = 1'-0"1ECO-GRIP TO TILE TRANSITION AT FOOT TRAFFIC AREA
6" = 1'-0"6ECO-GRIP BASE AT CABINET SIDE
6" = 1'-0"4ECO-GRIP BASE AT CABINET FRONT
6" = 1'-0"10ECO-GRIP BASE AT BAR DIEWALL
6" = 1'-0"9ECO-GRIP CLAMPING FLOOR SINK FLOOR FINISH DETAIL
3" = 1'-0"11ECO-GRIP BASE CAP AT MOP SINK CURB6" = 1'-0"20SST BACKSPLASH TO TILE TRANSITION 6" = 1'-0"16SS BACKSPLASH TO TILE TRANSITION
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
A
2301 N Tustin Ave
#A8/22/2024
MI
N
.
B
L
O
C
K
I
N
G
(
V
I
F
)
3'
-
1
1
/
4
"
(
9
2
0
M
M
)
(2
3
0
M
M
)
6"
CENTER OF MENU BOARDS AT
7' - 4" (2235MM) A.F.F. MIN.,
8' - 6" (2590MM) A.F.F. MAX.
SEE INTERIOR ELEVATIONS
FOR ACTUAL DIMENSION
3/4" PLYWOOD BACKING
BEHIND WALL FINISH,
SECURED TO STRUCTURE
METAL RECESSED CABLE
MANAGEMENT AND POWER
STORAGE BOX. MINIMUM (1)
RECEPTACLES AND (1) DATA
PORT PER SCREEN. MINIMUM
(4) OUTLETS AND (4) DATA
PORTS PER STORE.
CENTER OF MENU
ASSEMBLY
3' - 8 1/4"3' - 8 1/4"
4"4"4"4"6"6"4"4"
2' - 9"2' - 9"
MIN. OFFSET (TYP.)
6"WALL MOUNTED
MENU BOARD
BRACKET
DIGITAL SCREEN
EQ
EQ
EQ.11' - 0 1/2" (3364.2MM 3 SCREENS)EQ.
12' - 0 1/2" (3670.3 MM MIN. BLOCKING (VIF))
MI
N
.
O
F
F
S
E
T
(
T
Y
P
.
)
6"
MAX. LENGTH DATA (5'-6")
MAX. LENGTH POWER (5'-6")
r 5' - 6"
r 5' - 6"
EDGE OF DIGITAL SCREEN
WALL MOUNTED ORDER STATUS
BOARD MOUNTING BRACKET
SEE INTERIOR ELEVATIONS
FOR ACTUAL DIMENSION
3/4" PLYWOOD BACKING BEHIND
WALL FINISH, SECURED TO
STRUCTURE
METAL RECESSED CABLE
MANAGEMENT AND POWER STORAGE
BOX. MINIMUM (1) RECEPTACLES AND
(1) DATA PORT PER SCREEN.
2'
-
1
0
1
/
4
"
6"
3'
-
8
1
/
2
"
6"
6"2' - 2"6"
4'
-
8
1
/
2
"
M
I
N
.
B
L
O
C
K
I
N
G
(
V
I
F
)
3' - 2" MIN. BLOCKING (VIF)
DELL WYSE AND POWER BRICK
SECURED TO MOUNTING BRACKET
DEVICE CAGE
TOP OF ORDER STATUS BOARD FOR
UNOBSTRUCTED VIEW PLACEMENT
8' - 9" (2670MM) A.F.F. MAX.
7' - 6" (2290MM) A.F.F. PREFERRED
6' - 6" (1980MM) A.F.F MINIMUM
TOP OF ORDER STATUS BOARD FOR
ABOVE BAR COUNTERTOP PLACEMENT
8' - 9" (2670MM) A.F.F. MAX.
8' - 4" (2540MM) A.F.F. PREFERRED
7' - 6" (2290MM) A.F.F MINIMUM
EQ EQ
MIN.
OFFSET
DISTANCE
(TYP.)
RECEPTACLE FOR
REFRIGERATOR
AND/OR FREEZER
AT 84" (2135MM)
AFF
BACK WALL
RECEPTACLE FOR
SANITIZER AT 18"
(460MM) A.F.F.
BACK WALL
MOP SINK
WATER FILTRATION SYSTEM
(ABOVE)
GFCI 120V DUPLEX RECEPTACLE FOR
BOOSTER PUMP ABOVE INSTALLED AT
FACE OF WALL AT 8'-9" (2670MM) A.F.F.
(915MM)
3' - 3"
(75MM)
3"
GFCI 120V DUPLEX
RECEPTACLE FOR
WATER FILTRATION
SYSTEM AT 54"
(1370MM) A.F.F.
(305MM)
1' - 0"
GFCI 120V QUAD
RECEPTACLE FOR
WATER FILTRATION
SYSTEM AT 76"
(1930MM) A.F.F.
.6" (152MM) MIN.
CLEAR TO BACK
WALL
ELEVATION - ELECTRICAL DIAGRAM
PLAN - ELECTRICAL DIAGRAM
ICE DIVERTER
VALVE
CONT. FRP ON
BACK WALL OFER IN
WALL BLOCKING
BACK WALL
ICE BIN
ICE MACHINE
ICE HEAD ADAPTER
POWER
RECEPTACLES FOR
NUGGET ICE AT 72"
(1920MM) A.F.F.
ICE BIN
SENSOR CABLE
POWER CORD
ICE MACHINE
ICE HEAD ADAPTER
BIN TOP SENSOR
DISTRIBUTION UNIT
ICE DIVERTER
VALVE
6'
-
0
"
EQ EQ
POWER
RECEPTACLES FOR
NUGGET ICE AT 72"
(1920MM) A.F.F.
3"
EQ EQ
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
5
2
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I504
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ELECTRICAL DETAILS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
3/4" = 1'-0"1DIGITAL MENU BOARDS - STANDARD MOUNT
3/4" = 1'-0"3ORDER STATUS BOARD INFRASTRUCTURE3/4" = 1'-0"11REFRIGERATOR/FREEZER - ELECTRICAL
3/4" = 1'-0"12SANITIZING WORKSTATION - ELECTRICAL3/4" = 1'-0"16WATER FILTRATION - CONFIGURATION III
Revision Schedule
Rev Date By Description
3/4" = 1'-0"13ELECTRICAL - NUGGET ICE
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
NOTE:EQUIPMENT SHOWN AS DASHED LINES IS TO BE FURNISHED
AND INSTALLED BY OWNER UNLESS NOTED OTHERWISE.
PLAN VIEW
ELEVATION VIEW
1
380MM
1' - 3"
4'
-
0
"
(
1
2
2
0
M
M
)
A
.
F
.
F
.
SECURE KEY BOX 110MM
4 1/4"
CEILING HEIGHT SHOWN AT 96"
(2440MM). REFER TO REFLECTED
CEILING PLAN(S) FOR ACTUAL HEIGHT.
LOW VOLTAGE
CABLE BUNDLE
1 MUSIC SYSTEM
PLAY NETWORK
SPEAKERS
2" (50MM) Ø SLEEVE FOR LOW
VOLTAGE CABLE BUNDLE
MOUNTED TO (2) UNISTRUTS
CEILING TRIM RING
PRINTER
ROLLING CART
IPOD TOUCH
CHARGING CRADLE
CASH SCALE
HOME PHONE
CONNECT (HPC)
60" W X 70" H (1525MM W X
1780MM H) MIN. 3/4" FIRE
RATED PLYWOOD BACKER
BOARD. FASTEN TO
STRUCTURE TO HOLD MIN.
350 PSF. PAINTABLE
SURFACE ON ROOM SIDE &
FINISH AS SCHEDULED.
POWER, TELEPHONE & DATA
RECEPTACLES AT 12" (305MM) A.F.F.
TO CENTER OF GROUPING. SEE
FLAN VIEW NOTE "A" ABOVE FOR
DESCRIPTION.
POWER & DATA RECEPTACLES
AT 60" (1525MM) A.F.F. TO CENTER OF
GROUPING. SEE NOTE 'B' ABOVE FOR
DESCRIPTION.
DESK
OFFICE PC
LAPTOP
25MM
1"
SLEEVE FOR LOW VOLTAGE CABLE
BUNDLE MOUNTED TO (2) UNISTRUTS
2
2
670MM
2' - 2 1/4"
ROLLING CART
SHELVING ABOVE POWER & DATA RECEPTACLES
(IN WALL, AT MUSIC SYSTEM SHELF)
(1) DUPLEX RECEPTACLE FOR:
MUSIC SYSTEM AMPLIFIER AND
FUTURE USE
(1) 2-DATA PORT FOR:
CURIO
POWER, TELEPHONE & DATA RECEPTACLES
(IN WALL, BELOW DESK)
(1) QUAD RECEPTACLE FOR:
PC, PRINTER, PHONE AND HPC
(1) QUAD RECEPTACLE FOR:
LAPTOP, CASH SCALE AND FUTURE USE
(1) QUAD RECEPTACLE
(1) PHONE MAIN
(1) 2-DATA PORT FOR:
PC AND PRINTER
DESK
A
B
WALL MOUNTED SHELVING UNIT
ATTACHED TO BACKER BOARD
CORDLESS 1 LINE PHONE
MUSIC SYSTEM PLAYER AND
AMPLIFIER (FURNISHED BY
OWNER, INSTALLED WITH
SPEAKER SYSTEM BY GC) ON
14" DEEP (355MM) SHELF ONLY
(MIN.)
56" W X 42" H (1420MM W X 1065MM H) MIN. 3/4"
FIRE RATED PLYWOOD BACKER BOARD. FASTEN
TO STRUCTURE TO HOLD MIN. 350 PSF.
PAINTABLE SURFACE ON ROOM SIDE AND FINISH
AS SCHEDULED.
MINI GROUND BAR FOR EQUIPMENT RACK. GC TO
COORDINATE RACK GROUNDING TO BAR WITH #6
GROUND WIRE AND PER JURISDICTIONAL
REQUIREMENTS
POWER & DATA RECEPTACLES AT 87" (2210MM)
A.F.F. TO CENTER OF GROUPING. SEE PLAN VIEW
NOTE "A" ABOVE FOR DESCRIPTION.
EQUIPMENT RACK WALL MOUNTED TO STRUCTURE
BY STARBUCKS VENDOR (GC TO COORDINATE
INSTALLATION). GROUND RACK PER MFR'S
ASSEMBLY INSTRUCTIONS. SEE EQUIPMENT RACK
SCHEDULE BELOW FOR EQUIPMENT INCLUDED
WITHIN.
PLAN VIEW
MOUNT GROUND BAR AT 116" (2945MM) A.F.F.
ELEVATION VIEW
610MM
2' - 0" CLEAR
7'
-
0
"
EQEQ
.
65MM
2' - 2 1/2"
(2) 2" (50 MM) Ø SLEEVES
FOR LOW VOLTAGE CABLE
BUNDLES MOUNTED TO
(2) UNISTRUTS
CEILING TRIM RING (TYP.)
ENLARGED VIEW
LAY-IN CEILING
UPS
IPS EQUIPMENT
ROUTER
EQUIPMENT RACK SCHEDULE
NETWORK SWITCH
PATCH PANEL
SECURITY RECORDER (NVR)
SECURITY KEYBOARD
PRODUCTION CONTROLLER DEVICES
NOTE:EQUIPMENT SHOWN AS DASHED
LINES IS TO BE FURNISHED AND
INSTALLED BY OWNER UNLESS
NOTED OTHERWISE.
MOUNT EQUIPMENT RACK AT 84" (2133MM) A.F.F.
76" (1930MM)
CLEAR AREA
BELOW FOR
TRASH
CONTAINERS,
STORAGE OR
DELIVERY
DROP OFF
WIRELESS MODEM AT 92"
(2335MM) A.F.F. STARBUCKS
VENDOR TO DETERMINE
OPTIMAL DEVICE LOCATION
DEMARC, IF REQUIRED
POWER AND DATA
RECEPTACLES AT 104"
(2642MM) A.F.F. TO
CENTER OF GROUPING.
SEE NOTE 'B' ABOVE FOR
DESCRIPTION
SECURITY MONITOR
MOUNTED ON MONITOR
ARM (ATTACHED TO
BACKER BOARD).
BACK OF HOUSE CEILING
HEIGHT PER PLAN
21
6"
6"
15
0
M
M
.
15
0
M
M
.
..4"
100MM
LOW VOLTAGE CABLE BUNDLES
SECURITY PANEL
FUTURE USE
- - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - -
1 SECURITY 2 POS
HIGH SPEED INTERNET
DEMARC EXTENSION
POS LAN
DT TIMER
SECURITY
CONTROL
ALARM PANEL
EMS DATA
CONCENTRATOR.
ALLOW 2" (50MM)
IN. CLEAR ABOVE
MAINTAIN 24" (610MM) MIN.
CLEARANCE FOR WHEN
EQUIPMENT RACK IS IN
OPEN ACCESS POSITION
(2) SLEEVES FOR
LOW VOLTAGE CABLE
BUNDLES MOUNTED
TO (2) UNISTRUTS
EQUIPMENT RACK
POWER & DATA RECEPTACLES
(IN WALL, ABOVE SHELVES)
(1) QUAD RECEPTACLE FOR:
EMS DATA CONCENTRATOR
(1) DUPLEX RECEPTACLE FOR:
SECURITY CONTROL ALARM PANEL
(1) 2-DATA PORT FOR:
EMS DATA CONCENTRATOR
B
2
A POWER RECEPTACLES
(IN WALL, BEHIND OF EQUIPMENT RACK)
(1) INDIVIDUAL BRANCH CIRCUIT RECEPTACLE FOR:
UPS
(1) DUPLEX RECEPTACLE FOR:
PDU STRIP AND FUTURE USE
IOT GATEWAY
2' - 8"
DUPLEX RECEPTACLE FOR
OPTIONAL MICROWAVE AT 43"
(1090MM) A.F.F.
OPTIONAL MICROWAVE
ON COUNTERTOP
BACK WALL
EDGE OF
COUNTERTOP
DUPLEX RECEPTACLE
RECEPTACLES AT 28" FOR
UNDERCOUNTER FRIDGE
UNDERCOUNTER
REFRIGERATOR
CONVENIENCE DUPLEX RECEPTACLE
AT 43" (1090MM) A.F.F.
PARTNER SINK
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
5
3
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I504A
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ELECTRICAL DETAILS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
3/4" = 1'-0"1MANAGER DESK (NEW) - LEFT - ELECTRICAL3/4" = 1'-0"9EQUIPMENT RACK RIGHT - ELECTRICAL
3/4" = 1'-0"4PARTNER REST WETBAR - ELECTRICAL
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
EXTERIOR ELEVATIONINTERIOR ELEVATION
DOOR
ACTUATOR
MOUNTED
TO 4" X 6"
BOLLARD
4/18 GA.
WIRE FROM
EXTERIOR
ACTUATOR
TO INTERIOR
DOOR
OPERATOR
WIRE IN
CONDUIT
EMBEDDED
IN CONCRETE
OUTLINE OF DOOR
OPERATOR AT INTERIOR
WIRE FROM
KEY SWITCH
TO INTERIOR
DOOR
OPERATOR
DOOR
OPERATOR
KEY
SWITCH
J-BOX WITH
INLINE SWITCH
OR ON
DEDICATED
BREAKER 120V AC
4/18 GA.
WIRE FROM
ACTUATORS
TO OPERATOR
DEDICATED
RECEPTACLE FOR
INSTANT HOT
WATER BOILER AT
26" (660MM) A.F.F.
(200MM)
8"
(240MM)
9 1/2"
DUPLEX
RECEPTACLE AND
DATA PORT AT 47"
(1190MM) A.F.F.
SHELVING ABOVE
1'
-
6
"
WW
POWER RECEPTACLE
AT 18" (457MM) TO
TOP OF RECEPTACLE
A.F.F.
RECEPTACLE FOR
WARMING WALL
POWER RECEPTACLE
AT 18" (457MM) TO
TOP OF RECEPTACLE
A.F.F.
EQ EQ
5' - 0"
UNDERCOUNTER
REFRIGERATOR
QUAD RECEPTACLE
FOR LICENSED
STORES DPM TABLET
AND FUTURE USE
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR
2-DATA PORT FOR
LICENSED STORES
DPM TABLET AND
SPARE
POWER AND
DATA RECEPTACLES
AT 28" (711MM) TO TOP
OF RECEPTACLE A.F.F.
2
6"
COUNTERTOP
GROMMET FOR DPM
TABLET (ONLY FOR
LICENSED STORES
PROJECTS)
1'
-
5
"
5"
CEILING
ELEVATION - ELECTRICAL DIAGRAM
22 22
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR
RECEPTACLE FOR
BLENDER(S)*
RECEPTACLE FOR
FUTURE USE
2-DATA PORT FOR
LABEL PRINTER
2-DATA PORT FOR
FUTURE USE
*BLENDER
QUANTITY BASED
ON EQUIPMENT
SCHEDULE
POWER AND DATA
RECEPTACLES AT 28"
(710MM) TO TOP OF
RECEPTACLE A.F.F.
UNDERCOUNTER
NITRO
REFRIGERATOR
RECEPTACLE FOR
UNDERCOUNTER
NITRO REFRIGERATOR
RECEPTACLE FOR
NITROGEN
GENERATOR
RECEPTACLE FOR
DPM TABLET
2-DATA PORT FOR
DPM TABLET AND
FUTURE USE
POWER AND DATA
RECEPTACLES AT 28"
(710MM) TO TOP OF
RECEPTACLE A.F.F.
POWER RECEPTACLE
FOR RINSE SINK AT
28" (710MM) TO TOP
OF RECEPTACLE
A.F.F.
UNDERCOUNTER REFRIGERATOR
UNDERCOUNTERNITROGEN
GENERATOR
PLAN - UPPER ELECTRICAL DIAGRAM
2
RECEPTACLE FOR
MILK DISPENSER
RECEPTACLE FOR
ICE DISPENSER
RECEPTACLE FOR
LABEL PRINTER AND
FUTURE USE
2-DATA PORT FOR
LABEL PRINTER
POWER AND DATA
RECEPTACLES AT 83"
(2100MM) TO TOP OF
RECEPTACLE A.F.F.
RECEPTACLE FOR
MILK DISPENSER
POWER AND DATA
RECEPTACLES AT 83"
(2100MM) TO TOP OF
RECEPTACLE A.F.F.
2'
-
4
"
6'
-
1
1
"
POWER AND DATA
RECEPTACLES AT 28"
(710MM) TO TOP OF
RECEPTACLE A.F.F.
SOFFIT
POWER AND DATA
RECEPTACLES AT 83"
(2030MM) TO TOP OF
RECEPTACLE A.F.F.
PLAN - ELECTRICAL DIAGRAM
JBOX FOR
UNDERCABINET
LIGHTING
2
1' - 2"2' - 6 1/2"3' - 3 1/2"1' - 2 1/2"
4' - 6 3/4"1' - 0"2' - 9 3/4"
11' - 6"
11' - 6"
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
5
/
2
0
2
4
1
0
:
2
3
:
0
1
A
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I504B
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ELECTRICAL DETAILS
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
1/2" = 1'-0"1ENTRY/EXIT DOOR ACTUATION - ELECTRICAL WIRING DIAGRAM
3/4" = 1'-0"3WATER FILLING STATION - ELECTRICAL3/4" = 1'-0"7WARMING WALL 1000 ELECTRICAL
3/4" = 1'-0"4MOP 07-04 ELECTRICAL
3/4" = 1'-0"9CB CBE 15 ELECTRICAL
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
A
A
2301 N Tustin Ave
#A8/22/2024
2 2
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR
RECEPTACLE FOR
LABEL PRINTER
AND FUTURE USE
2-DATA PORT FOR
LABEL PRINTER
POWER AND DATA
RECEPTACLES AT 28"
(710MM) TO TOP OF
RECEPTACLE A.F.F.
RECEPTACLE FOR
COMBI OVEN
2-DATA PORT COMBI
OVEN
POWER AND DATA
RECEPTACLES AT 18"
(457MM) TO TOP OF
RECEPTACLE A.F.F.
POWER AND DATA
RECEPTACLES AT 28"
(710MM) TO TOP OF
RECEPTACLE A.F.F.
POWER AND DATA
RECEPTACLES AT 18"
(457MM) TO TOP OF
RECEPTACLE A.F.F.
ELEVATION - ELECTRICAL DIAGRAM
ELEVATION - ELECTRICAL DIAGRAM
1' - 4"3' - 11"1' - 1"
6' - 4"
4"4"
2'
-
4
"
1'
-
6
"
UNDERCOUNTER
REFRIGERATORS
2' - 2"1' - 7"
11' - 7"
3' - 6 3/4"3' - 7 1/4"2' - 0 3/4"
1"
(
T
Y
P
.
)
DEDICATED
RECEPTACLE FOR
ESPRESSO MACHINE
DEDICATED
RECEPTACLE FOR
INSTANT HOT WATER
BOILER
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR AND
FUTURE USE
POWER
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
IoT MODULE FOR
ESPRESSO MACHINE,
FOIO (TYP. 1 OF 2)
(2) RECEPTACLES FOR LABEL PRINTERS AND/OR CONNECT DEVICES
2-DATA PORT FOR LABEL PRINTERS AND/OR CONNECT DEVICES
2-DATA PORT FOR FUTURE USE
POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F.
21” X 3” (533MM X 76MM) STUB-UP
PENETRATION AREA. SUPPLY
POWER AND DATA CONDUIT FOR
ESPRESSO MACHINES, INSTANT
HOT WATER BOILERS AND
ADJACENT NITRO WORKSTATION
AS APPLICABLE. SEE BUILDING
FLOOR PENETRATION FOR FINAL
LOCATION.
DEDICATED RECEPTACLE
FOR ESPRESSO MACHINE
DEDICATED RECEPTACLE
FOR INSTANT HOT
WATER BOILER
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR AND
FUTURE USE
POWER
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
UNDERCOUNTER
WATER BOILER FOR
INSTANT HOT WATER
FONT (TYP. 1 OF 2)
2 2 IoTIoT
7' - 6"
QUAD RECEPTACLE
FOR LABEL
PRINTER, FUTURE
USE AND/OR
CONNECT DEVICES
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR
2-DATA PORT FOR
LABEL PRINTER
2-DATA PORT FOR
FUTURE USE
POWER AND DATA
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
(2) DEDICATED
RECEPTACLE FOR
WARMING
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR
2-DATA PORT FOR
FUTURE USE
POWER AND
DATA RECEPTACLES
AT 28" (711MM) TO TOP
OF RECEPTACLE A.F.F.
UNDERCOUNTER
REFRIGERATOR
UNDERCOUNTER
REFRIGERATOR
4"
4"4"
2 2
2' - 1"4' - 2"
2
3' - 1 1/2"1' - 3"
7' - 6"
1/
2
"
QUAD RECEPTACLE
FOR GRINDER AND
FUTURE USE
DATA PORT FOR
FUTURE USE
POWER AND
DATA RECEPTACLES
AT 28" (711MM) TO TOP
OF RECEPTACLE A.F.F.
DEDICATED
RECEPTACLE FOR
BREWER
DATA PORT FOR
FUTURE USE
POWER AND
DATA RECEPTACLE AT
28" (711MM) TO TOP OF
RECEPTACLE A.F.F.
2' - 0"
2"
PARTNER SIDE
POWER AND DATA RECEPTACLES
DEDICATED RECEPTACLE FOR
UPS (POS AND PED)
2-DATA PORT FOR POS PED
AND/OR CONNECT DEVICES
(RELOCATE AS NECESSARY)
POWER AND DATA
STUB-UPS. SEE
BUILDING FLOOR
PENETRATION PLAN
FOR FINAL LOCATION.
POS BANK (TYP.)
SAFE (MAY NOT BE
INSTALLED AT ALL POS
WORKSTATION TYPES)
POS MONITOR (TYP.)
NOTE:
GENERIC DETAIL IS FOR INFORMATION AND
COORDINATION ONLY; ENGINEER TO MODIFY
AS APPROPRIATE
RECEIPT PRINTER (TYP.)
CASH DRAWER (TYP.)
DEDICATED RECEPTACLE
FOR UPS (POS AND PED)
2-DATA PORT FOR PED
AND/OR CONNECT DEVICES
QUAD RECEPTACLE FOR
SAFE AND FUTURE USE
2-DATA PORT FOR FUTURE
USE
POWER AND DATA RECEPTACLES
(RELOCATE AS NECESSARY)
18" X 3" (457MM X 76MM)
STUB-UP PENETRATION
AREA. SUPPLY POWER,
DATA AND PHONE
CONDUITS FOR POS
AND POWER CONDUIT
FOR PASTRY CASE.
SEE BUILDING FLOOR
PENETRATION PLAN
FOR FINAL LOCATION.EDGE OF COUNTERTOP
BOX BASE (BELOW)UNDERCOUNTER
SAFE
EDGE OF CABINET
SHELVING (BELOW)
6' - 10"
DEDICATED RECEPTACLE
FOR POS
2-DATA PORT FOR POS
AND FUTURE USE
POWER AND
DATA RECEPTACLES AT
28" (711MM) TO TOP OF
RECEPTACLE A.F.F.
2 2 2
DEDICATED RECEPTACLE
FOR UPS (POS AND PED)
2-DATA PORT FOR POS,
PED AND/OR CONNECT
DEVICES
POWER RECEPTACLES
AT 28" (711MM) TO TOP
OF RECEPTACLE A.F.F.
QUAD RECEPTICLE
FOR FUTURE USE
2-DATA PORT FOR
FUTURE USE
POWER RECEPTACLES
AT 28" (711MM) TO TOP
OF RECEPTACLE A.F.F.
4' - 4"1' - 3"
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
5
5
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I504C
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ELECTRICAL DETAILS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
3/4" = 1'-0"1CB WRM 14 ELECTRICAL3/4" = 1'-0"9ESP 10-01 ELECTRICAL
3/4" = 1'-0"11WRM 08-02 ELECTRICAL
3/4" = 1'-0"12BRW 09-01 ELECTRICAL
NOT USED
NOT USED
3/4" = 1'-0"4GENERIC DOUBLE POS ELECTRICAL & PLLUMBING DIAGRAM
3/4" = 1'-0"3POS 01-01 ELECTRICAL
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
1' - 3"1' - 9"
6' - 6"
42
2
DEDICATED QUAD RECEPTACLE FOR DT
DIGITAL PRODUCTION MONITOR, UPS UNIT
(FOR TENDERING REGISTER EXPEDITOR,
POS AND PED) AND FUTURE USE
DEDICATED QUAD RECEPTACLE FOR
FUTURE USE
2-DATA J-BOX
4-DATA J-BOX
POWER AND DATA RECEPTACLES
DEDICATED QUAD RECEPTACLE FOR DRIVE
THRU TIMER MONITOR AND CONTROL UNIT.
(2) DEDICATED DUPLEX RECEPTACLE FOR
WIRELESS BASE AND SIGNAL PROCESSOR
WITH CIRCUIT ISOLATED GROUND
2-DATA J-BOX
SINGLE DATA J-BOX
POWER AND DATA RECEPTACLES
QUAD RECEPTACLE
FOR UNDERCOUNTER
REFRIGERATOR AND
FUTURE USE
POWER RECEPTACLE
UNDERCOUNTER
REFRIGERATOR
DUPLEX CONVENIENCE
POWER RECEPTACLE
EDGE OF COUNTERTOP
NOTE: EQUIPMENT SHOWN AS
DASHED LINES IS TO BE
FURNISHED AND INSTALLED
BY OWNER UNLESS NOTED
OTHERWISE
DRIVE THRU DIGITAL
PRODUCTION MONITOR
ELEVATION VIEW
DRIVE THRU TENDERING REGISTER
TRIPLE MONITOR MOUNT (GC INSTALLED)
SEE PLAN VIEW FOR MOUNTING LOCATION
POWER RECEPTACLES AT 28" (711MM) TO
TOP OF RECEPTACLE A.F.F.
DEDICATED QUAD RECEPTACLE FOR DT
DIGITAL PRODUCTION MONITOR, UPS UNIT
(FOR TENDERING REGISTER, EXPEDITOR
POS AND PED) AND FUTURE USE
DEDICATED QUAD RECEPTACLE FOR
FUTURE USE
2-DATA PORT FOR TENDERING REGISTER
AND EXPEDITOR POS
4-DATA PORT FOR DT VIDEO, PED AND/OR
CONNECT DEVICES
POS BANK (TYP)
CASH DRAWERS
ELEVATION VIEW
DRIVE THRU VIDEO CONDUIT FROM DT ORDER POINT TO
DT VIDEO DATA BOX AT 28" (711MM) A.F.F.
DRIVE THRU EXPEDITOR POS
RECEIPT PRINTER
DT AUDIO CONDUIT FROM
DRIVE THRU ORDER POINT
AND DETECTOR LOOP
CONDUIT FROM DT
WINDOW TO DT TIMER
CONTROL DATA JUNCTION
BOXES AT 8'-2" (2490MM)
POWER RECEPTACLE AT
28" (711MM) TO TOP OF
RECEPTACLE A.F.F.
QUAD RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR AND
FUTURE USE
SINGLE DOOR
REFRIGERATOR
DUPLEX CONVENIENCE
OUTLET AT 45" (1143MM) TO
TOP OF RECEPTACLE A.F.F.
*
5
"
* 1' - 11 1/2"
DIMENSIONS INDICATE CENTER
MOUNTING POINT FOR MONITOR BASE
*
DRIVE THRU WIRELESS HEADSET
BASE STATION
DRIVE THRU TIMER MONITOR
DRIVE THRU TIMER CONTROL UNIT
POWER AND DATA RECEPTACLES AT 8'-2" (2490MM)
TO TOP OF RECEPTACLES A.F.F.
DEDICATED QUAD RECEPTACLE FOR DRIVE
THRU TIMER MONITOR AND CONTROL UNIT
(2) DEDICATED DUPLEX RECEPTACLE FOR
WIRELESS BASE AND SIGNAL PROCESSOR
WITH CIRCUIT ISOLATED GROUND
2-DATA PORT FOR DT TIMER AND CONTROL UNIT
SINGLE DATA PORT FOR DT AUDIO
(MIC & SPEAKER)
DRIVE THRU TIMER SIGNAL PROCESSOR (TSP)
36" W X 51" H (915MM W X 1295MM H) MIN. FIRE
RATED PLYWOOD BACKER BOARD. FASTEN TO
STRUCTURE. WALL FINISH TO CONCEAL.
FUTURE HHOP CABLING TO HEADSET BASE
STATION FROM J-BOX AT CLG/WALL FOR
EXTERNAL EXTENDED COVERAGE ANTENNA
(FOIO)
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
5
5
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I504D
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
ELECTRICAL DETAILS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
3/4" = 1'-0"1DTP 03-02 ELECTRICAL
NOT USEDNOT USEDNOT USEDNOT USEDNOT USED
NOT USEDNOT USEDNOT USED
NOT USEDNOT USEDNOT USED
NOT USEDNOT USEDNOT USED
Revision Schedule
Rev Date By Description
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
OPTIONAL MICROWAVE
ON COUNTERTOP
BACK WALL
EDGE OF
COUNTERTOP
UNDERCOUNTER
REFRIGERATOR
PARTNER SINK
HOT AND COLD WATER
FOR SINK FAUCET AT 20
1/2" (520MM) A.F.F. SHUT-
OFF VALVES AT WALL
AND 4" (100MM) EITHER
SIDE OF WASTE LINE.
DIRECT DRAIN LINE FROM
RINSE SINK
HOT AND COLD WATER
FOR SINK FAUCET AT 20
1/2" (520MM) A.F.F. SHUT-
OFF VALVES AT WALL
AND 4" (100MM) EITHER
SIDE OF WASTE LINE.
FILTERED
COLD WATER
SUPPLY FOR
BREWER WITH
SHUT-OFF IN
CABINET AT
24" (610MM)
A.F.F.
7' - 6"
*
PROVIDE BACKFLOW PREVENTION DEVICE THEN
WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF
VALVE AND FLEX HOSE CONNECTION
*
FLOOR SINK
10"
F
L
O
O
R
S
I
N
K
2'
-
5
1
/
2
"
SEE PLUMBING PLAN FOR FINAL
FLOOR SINK LOCATION AND TYPE
INDIRECT DRAIN LINE FROM
RINSE SINK TO FLOOR SINK
INDIRECT
DRAIN LINE
FROM
BREWER TO
FLOOR SINK
DIRECT DRAIN LINE FROM
SINK. ROUGH-IN SINK
WASTE STUB AT 15 1/2"
(394MM) A.F.F. AND
CENTERLINE OF SINK
TEMPERED HOT AND COLD
WATER FOR SINK FAUCET
AT 20 1/2" (520MM) A.F.F.
SHUT-OFF VALVES AT WALL
AND 4" (102MM) EITHER
SIDE OF WASTE LINE.
7 1/2"
1' - 3"
FILTERED COLD WATER
SUPPLY FOR WATER
TOWER FAUCET*
FILTERED
COLD WATER
SUPPLY FOR
INSTANT
HOT/COLD
WATER FONT
NON-FILTERED
HOT AND COLD
WATER SUPPLY
FOR SINK
FAUCET
ABOVE COUNTERTOP
AT FLOOR LEVEL
INDIRECT LINE
FROM PREP
SINK ABOVE TO
FLOOR SINK
SHELVING
ABOVE
FILTERED COLD
WATER SUPPLY FOR
UNDERCOUNTER
INSTANT HOT
WATER BOILER
(LOCATION MAY
VARY)
**
PROVIDE WATER HAMMER ARRESTOR PRIOR TO
SHUT-OFF VALVE AND FLEX HOSE CONNECTION*
IN-WALL INDIRECT
DRAIN LINE FROM
ICE DISPENSER TO
FLOOR DRAIN
OUTLET BOX FOR
INDIRECT DRAIN
LINE
FLOOR DRAIN
SOFFIT
OUTLET BOX FOR
INDIRECT DRAIN
LINE
FLOOR DRAIN
OUTLET BOX FOR
INDIRECT DRAIN
LINE
1'
-
0
"
4'
-
7
1
/
2
"
CEILING
OUTLET BOX FOR
INDIRECT DRAIN
LINE
ICE TRANSPORT TUBE
LANE 1, TO ICE
DISPENSER. MAX
LENGTH 75', MIN. SLOPE
1/4":1'.
CONTINUOUS CONDUIT
FASTENED W/ STRAPING
@ 48" O.C. MIN.
CEILING
IN-WALL INDIRECT
DRAIN LINE FROM
ICE DISPENSER TO
FLOOR DRAIN
SOFFIT
INDIRECT LINE FROM
DRAINBOARD TO FLOOR
SINK
HOT AND NON-FILTERED COLD
WATER FOR SINK FAUCET AT
20 1/2" (20MM) A.F.F. SHUT-OFF
VALVES AT WALL AND 4" (100MM)
EITHER SIDE OF WASTE LINE
NON-FILTERED COLD WATER SUPPLY
FOR BLENDER PITCHER RINSER
INDIRECT DRAIN LINE FROM SINK
TO FLOOR SINK
FILTERED COLD WATER
SUPPLY FOR WATER TOWER
FAUCET
DRAIN LINES FROM
DRAIN TRAY AND
UNDERCOUNTER
REFRIGERATOR;
SEPARATE,
INDIRECT
TERMINATION AT
FLOOR SINK
SEE PLUMBING PLAN FOR FINAL
FLOOR SINK LOCATION AND TYPE
ELEVATION - PLUMBING DIAGRAMSECTION A - PLUMBING DIAGRAM
ACCESS DOOR
DOOR FACE W/
TAPERED EDGE
PULL
MOUNTING
TEMPLATE, BLACK
IN-WALL BLOCKING
REQUIRED,
PROVIDED BY G.C.
FRAMING, BLACK
ACCESS DOOR
ICE TRANSPORT
TUBE LANE 1, TO
ICE DISPENSER.
MAX LENGTH 75',
MIN. SLOPE 1/4":1'
CONTINUOUS CONDUIT
FASTENED W/ STRAPING
@ 48" O.C. MIN.
A
VA
R
I
E
S
11' - 6"
6"
6"
EQ EQ
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
5
/
2
0
2
4
1
0
:
2
3
:
0
3
A
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I505
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
PLUMBING DETAILS
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
3/4" = 1'-0"12PARTNER REST WETBAR - PLUMBING 3/4" = 1'-0"4BRW 09-01 PLUMBING
3/4" = 1'-0"17ADD 02-01 PLUMBING
3/4" = 1'-0"18WATER FILLING STATION - PLUMBING
NOT USED
3/4" = 1'-0"1CB CBE 15 PLUMBING
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
A
2301 N Tustin Ave
#A8/22/2024
11' - 7"
ABOVE COUNTER
ICE BIN (TYP. 1 OF 2)NON-FILTERED COLD
WATER SUPPLY FOR
METERED SPOON RINSER
(TYP. 1 OF 2)
NON-FILTERED COLD WATER
SUPPLY FOR PITCHER
RINSER (TYP. 1 OF 2)
RINSER SINK (TYP. 1 OF 2)
2'
-
1
0
1
/
2
"
UNDER COUNTER
ICE BIN ABOVE
WITH INDIRECT
AND INSULATED
DRAIN LINE TO
FLOOR SINK
BELOW
7"X3" (180MMX75MM) STUB-UP
PENETRATION AREA. SEE
BUILDING FLOOR
PENETRATION PLAN FOR
FINAL LOCATION. INSTALL
SHUT-OFF VALVES BETWEEN
STUB-UPS AND EQUIPMENT
INDIRECT DRAIN LINE FROM
ESPRESSO MACHINE TO
FLOOR SINK
INDIRECT DRAIN LINE FROM
RINSER SINK TO FLOOR SINK
FLOOR SINK (TYP. 1 OF 2)
SEE PLUMBING PLAN FOR
FINAL LOCATIONS AND
TYPE
ICE BIN ABOVE
WITH INDIRECT AND
INSULATED DRAIN
LINE TO FLOOR
SINK BELOW
COUNTERTOP SUPPORT
LEG (TYP. 1 OF 3)
INDIRECT DRAIN
LINE FROM
RINSER SINK TO
FLOOR SINK
UNDERCOUNTER
CABINET
UNDERCOUNTER
REFRIGERATOR
(TYP. 1 OF 2)
UNDERCOUNTER BOILER
FOR INSTANT HOT WATER
FONT (TYP 1 OF 2)
UNDERCOUNTER
REFRIGERATOR
(TYP. 1 OF 2)
11 1/2"6' - 1"
INDIRECT DRAIN LINE FROM
ESPRESSO MACHINE TO
FLOOR SINK
FILTERED COLD WATER
SUPPLY FOR INSTANT
HOT/COLD WATER FONT
(TYP. 1 OF 2)
*
FILTERED COLD WATER
SUPPLY FOR WATER
TOWER DISPENSER
(TYP. 1 OF 2)
*
FILTERED COLD WATER
SUPPLY FOR ESPRESSO
MACHINES
**
UNDERCOUNTER
CABINET
FILTERED COLD WATER
SUPPLY FOR INSTANT
HOT/COLD WATER BOILER
(TYP. 1 OF 2)
*PROVIDE WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND
FLEX HOSE CONNECTION*
**PROVIDE BACKFLOW PREVENTION DEVICE BEFORE PUMP AND WATER
HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE
ELEVATION - PLUMBING DIAGRAM
PLAN - PLUMBING DIAGRAM
6' - 6"
FLOOR DRAIN
FILTERED WATER
SUPPLY FOR COMBI
OVEN WATER INJECTION
WITH SHUT-OFF IN
CABINET AT 18" (457MM)
A.F.F.
COLD WATER SUPPLY
FOR COMBI OVEN
CLEANING WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
COLD WATER SUPPLY
FOR COMBI OVEN
CLEANING WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
FILTERED WATER
SUPPLY FOR COMBI
OVEN WATER
INJECTION WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
INDIRECT DRAIN LINE
FROM COMBI OVEN TO
FLOOR SINK
SEE PLUMBING PLAN
FOR FINAL FLOOR SINK
LOCATION AND TYPE
INDIRECT DRAIN
LINE FROM ICE
MACHINE TO FLOOR
DRAIN
SEE PLUMBING
PLAN FOR FINAL
FLOOR DRAIN
LOCATION AND
TYPE
.6" (152MM) MIN.
CLEAR TO BACK
WALL
INDIRECT DRAIN
LINE FROM ICE BIN
TO FLOOR DRAIN
INDIRECT DRAIN
LINE FROM ICE
DIVERTER TO
FLOOR DRAIN
ICE MACHINE
ICE TRANSPORT
TUBE BETWEEN ICE
MACHINE AND
DIVERTER VALVE.
MAX. LENGTH 10'
(3M)
ICE HEAD ADAPTER
ICE TRANSPORT
TUBE LANE 2, TO
ICE BIN. MAX
LENGTH 75', MIN.
SLOPE 1/4":1'
ICE TRANSPORT
TUBE LANE 1, TO
ICE DISPENSER.
MAX LENGTH 75',
MIN. SLOPE 1/4":1'
3" PVC SLEEVE TO
SUPPORT ICE
TRANSPORT
TUBEFASTENED TO
WALL OR CEILING
W/ STRAPING @ 48"
O.C. MIN.
ICE DIVERTER
VALVE
ELEVATION - PLUMBING DIAGRAM
PLAN - PLUMBING DIAGRAM
CONT. FRP TO
CEILING ON BACK
WALL OVER IN
WALL BLOCKING
ICE BIN
ICE MACHINE
ICE HEAD ADAPTER
NOTE:
INDIRECT DRAIN MIN. RADIUS = 8"
ICE TRANSPORT TUB MIN. RADIUS = 6"
NOTE:
INDIRECT DRAIN MIN. RADIUS = 8"
ICE TRANSPORT TUB MIN. RADIUS = 6"
ECO-GRIP COVER
BASE
ICE MANAGER
CONTROL PANEL
ICE DIVERTER
VALVE
CONT. FRP ON
BACK WALL OVER
IN WALL BLOCKING
BACK WALL
MIN.
r 6"
BIN TOP SENSOR
DISTRIBUTION UNIT
ICE BIN
INDIRECT DRAIN
LINE FROM ICE
MACHINE TO FLOOR
DRAIN
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
5
7
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I505A
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
PLUMBING DETAILS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
Revision Schedule
Rev Date By Description
3/4" = 1'-0"9ESP 10-01 PLUMBING
3/4" = 1'-0"11CB WRM-14 PLUMBING
NOT USED
NOT USED
3/4" = 1'-0"1PLUMBING - NUGGET ICE - PEDESTAL STACK1
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
CONFIGURATION III
WATER FILTRATION
SYSTEM. SEE
CONFIGURATION III, R.O.
AND SOFTENER DETAIL
FOR MORE
INFORMATION.
R.O. PERMEATE
TANK
FRP ENCLOSED
CL
E
A
R
6"
(
1
5
0
M
M
)
BA
C
K
E
R
4'
-
2
"
(
1
2
7
0
M
M
)
2'
-
6
"
(
7
6
5
M
M
)
7'
-
2
"
(
2
1
8
5
M
M
)
NOTE:
1. KEEP CLEAR AT BACKWALL FOR CHEMICAL DISPENSING SYSTEM COMPONENTS, TO BE INSTALLED BY SYSTEM VENDOR. REFER TO
POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION
2'
-
0
"
(
6
1
0
M
M
)
OPEN CEILING ABOVE
WATER HEATER PER
LOCAL CODE
STRAP UNITS PER LOCAL
CODE REQUIREMENTS
PROVIDE MOISTURE-
RESISTANT BLOCKING TO
STRUCTURE BEHIND
WALL FINISH AT THESE
AREAS. REFER TO ITEM
SPECIFICATIONS FOR
PLUMBING SCOPE;
COORDINATE INSTALL
WITH FILTER VENDOR.
FRP ENCLOSED
HOT WATER TANK. SEE
SPECIFICATIONS AND
WATER HEATER TANK
DETAIL FOR MORE
INFORMATION.
MOP HOLDER
3'
-
0
"
(
9
1
5
M
M
)
5'
-
0
"
(
1
5
2
5
M
M
)
HOSE CLIP
HOT AND COLD
WATER SUPPLY
FOR FAUCET
MOP SINK
SEE NOTE 1
BELOW
SEE NOTE 1
BELOW
2' - 0" (610MM)
6' - 0" (1830MM) MIN.
BLENDED STORAGE
TANK ON WALL
MOUNTED SHELF
WATER BOOSTER PUMP
SEE BOOSTER PUMP
DETAIL FOR MORE
INFORMATION.
FRP ENCLOSED
9'
-
6
"
(
2
8
9
5
M
M
)
T
O
B
O
T
T
O
M
O
F
B
L
E
N
D
E
D
S
T
O
R
A
G
E
T
A
N
K
SH
E
L
F
3/4" (20MM)
CHROME ESCUTCHEONS (TYP.)
3/4" (20MM)
BRASS THREADED BALL SHUT-OFF VALVE
(TYP.) MAX 72" (1830MM) A.F.F.
UNION (TYP.)
3/4" (20MM)
FILTERED COLD WATER
TO ICE MACHINE
POINT OF USE
FILTER LOCATED AT
ICE MACHINE
MOP SINK
NOTES:
1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. GC TO COORDINATE INSTALLATION OF ALL OTHER COMPONENTS SHOWN WITH FILTER VENDOR.
2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND FROM SOFTNER TO ADVANSYS DISHWASHER WHERE ALLOWED BY CODE.
3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES.
4. PROVIDE WATER SOFTENER INDIRECT DRAIN TO SINK, INSTALLED PER CODE. (CONFIRM REQUIREMENTS WITH SOFTENER EQUIPMENT CUTSHEETS IN ITEM SPECIFICATIONS).
5. IN MUNICIPALITIES WITH BRINE RESTRICTIONS, REFER TO THE WATER SYSTEM CONFIGURATIONS APPENDIX UNDER ITEM SPECIFICATIONS FOR WATER SOFTENER EXCHANGE TANK SCHEMATIC.
6. COMPONENTS ARE TO BE POSITIONED TO MAXIMIZE ACCESS FOR REGULAR SERVICING. PRE-FILTER, BYPASS VALVES, AND SOFTENER TANKS MUST BE INSTALLED 72" (1828MM) AFF OR LOWER.
R.O. PERMEATE
TANK
(180MM)
7"(235MM)
9 1/4"
GFCI 120V QUAD
RECEPTACLE FOR
FILTER SYSTEM 77"
(1955MM) A.F.F.
(SEE NOTE 3)FILTERED COLD WATER
TO FIXTURES (ESPRESSO
MACHINES, BREWERS,
HOT TAP, WATER TOWER
FAUCET)
75
"
(
7
9
0
5
M
M
)
OUT
R.O. CONTROL SYSTEM
(SEE NOTE 5)
3/4" (20MM)
SHUT-OFF
VALVE
3/4" (15MM)
FIP
3/4" (20MM) SHUT-OFF VALVE
3/4" (20MM) BYPASS
3/4" (20MM) SHUT-OFF
VALVE
CITY WATER IN
TO NON FILTERED
FIXTURES (TOILETS,
HAND SINKS, DIPPER
WELLS, BLENDER
PITCHER RINSERS,
IN-COUNTER RINSERS,
BAR SINKS, HOSE BIBBS)
3/4" (20MM) FIP
(FEMALE
INTERNATIONAL
PIPE THREAD
FITTING) (TYP. 1 OF
2 TO SOFTENER)
GFCI 120V
RECEPTACLE FOR
FILTER SYSTEM AT
54" (1372MM) A.F.F.
(SEE NOTE 3)
IN
DI EXCHANGE (EXISTING)
WATER SOFTENER
HEAD AND TANKS
(BEHIND)
DRAIN LINE FROM
WATER HEATER
TANK PAN ABOVE
255MM)
11"
3" (75MM)
WATER
HEATER TANK
SEE WATER
HEATER TANK
DETAIL FOR
MORE
INORMATION
FROM WATER
HEATER TANK
TEMPERING
VALVE
OUT
IN IN
TO HOT WATER TANK
AND ADVANSYS
DISHWASHER
PLUMBING. SEE
WATER HEATER TANK
DETAIL FOR MORE
INORMATION
BYPASS VALVE
BLENDED STORAGE
TANK ON WALL
MOUNTED SHELF
5'
-
0
"
(
1
5
2
5
M
M
)
TO R.O. SYSTEM
BOOSTER
PUMP
BYPASS
VALVE
3/4" (20MM)
CITY
WATER
IN
BOOSTER
PUMP
SHUT-OFF
VALVE
TO
BOOSTER
PUMP
3/4" (20MM)
BOOSTED
WATER IN
5'
-
9
"
(
1
7
5
0
M
M
)
WATER FILTRATION
BOOSTER PUMP.
SEE BOOSTER
PUMP DETAIL
FOR MORE
INFORMATION
HOT WATER TANK (SEE
SPECIFICATIONS & HOT WATER
TANK DETAIL FOR FURTHER
INSTALLATION REQUIREMENTS)
1" (25MM)
BRASS CHECK
VALVE
EXPANSION TANK
STRAP UNITS PER LOCAL
REQUIREMENTS
HOT WATER TO DISHWASHER
(IF OTHER THAN HOBART
ADVANSYS UNIT), BAR SINKS,
MOP SINK AND COMPARTMENT
SINK.
1" (25MM) HOT WATER OUTLET
TEMPERED HOT WATER TO
HAND SINKS
TEMPERATURE MIXING
VALVES
UNION (TYP.)CONCEALED
COPPER PIPING (TYP.)
IF CONFIGURATION II
OR III, SOFTENED
COLD WATER TO
DISHWASHER
(IF HOBART
ADVANSYS UNIT).
SEE NOTE 2 BELOW.
OPEN CEILING ABOVE
WATER HEATER PER
LOCAL CODE
PAN AND DRAIN LINE FOR
MAINTENANCE
BOOSTER PUMP.
SEE BOOSTER PUMP
DETAIL FOR MORE
INFORMATION.
FL
O
W
DI
R
E
C
T
I
O
N
NOTES:
1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY.
2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND ADVANSYS
DISHWASHER WHERE ALLOWED BY CODE.
3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES.
4.. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED..
SHELF PER
ENGINEER'S
DRAWINGS
FLOW
DIRECTION
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
5
8
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I505B
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
PLUMBING DETAILS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
Revision Schedule
Rev Date By Description
1/2" = 1'-0"1CONFIGURATION III1" = 1'-0"9CONFIGURATION III, R.O. AND SOFTENER WATER FILTRATION
3/4" = 1'-0"3WATER HEATER TANK - PLUMBING
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
Plan View
KEEP CLEAR FOR WALL MOUNTED CHEMICAL DISPENSING SYSTEM, TO BE INSTALLED
BY SYSTEM VENDOR. PROVIDE BACKING BEHIND WALL FINISH FOR EQUIPMENT
MOUNTING. REFER TO POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION.
Elevation View
SOFTENED HOT AND NON-FILTERED COLD WATER FOR SINK FAUCET
INDIRECT DRAIN LINE FROM DISHWASHER TO NEAREST FLOOR SINK.
BACK WALL
WATER FOR DISHWASHER WITH SHUT-OFF UNDER SINK AT 18" (460MM) AFF. LINE
LENGTH MUST ALLOW EASE OF MOVEMENT. VERIFY WATER REQUIREMENTS FOR
TYPE OF DISHWASHER (HOT/COLD/SOFTENED). SEE WATER SUPPLY DRAWINGS
FOR WATER LINE. IF ADVANSYS DISHWASHER, INCLUDE PRESSURE REDUCING
VALVE. PRESSURE GAUGE (SET TO 20 PSIG +/- 5 PSI), LINE STRAINER AND SHOCK
ARRESTOR.
DRAIN LINE FROM SINK TO FLOOR SINK BELOW
SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION. FLOOR DRAIN OPTIONAL.
WIRE RACK
COMPARTMENT SINK DISHWASHER
NOTE:
FOR COORDINATION ONLY. SEE FURNITURE, FIXTURES, AND EQUIPMENT PLAN
FOR EQUIPMENT LOCATIONS. PROVIDE BACKING BEHIND WALL FINISH AS
REQUIRED FOR WALL MOUNTED EQUIPMENT. REFER TO ITEM SPECIFICATIONS
FOR MORE INFORMATION.
PRE-WASH STATION
(1
3
7
0
M
M
)
4'
-
6
"
DRAIN LINE FROM DISHWARE DRYING RACKS TO SINK BOWL
DISHWARE DRYING RACKS WITH DRAIN LINE TO SINK BOWL
ALIGN
(1
1
9
5
M
M
)
3'
-
1
1
"
(9
6
5
M
M
)
3'
-
2
"
12' - 3"
3/4" PLYWOOD BACKER BOARD BEHIND WALL FINISH. FASTEN TO STRUCTURE
BEYOND.
B
MOP SINK AND WATER
FILTRATION EQUIPMENT.
SEE PLAN FOR ACTUAL
CONFIGURATION.
WATER HEATER TANK PER PLAN
HOT WATER TANK CHASE TO
STRUCTURE OR HARD LID
ABOVE. PAINT INTERIOR GWB
FINISH TO MATCH BOH FRP.
ROOF STRUCTURE PER PLAN
MIN CLEAR
2' - 8" (815MM)
7'
-
2
"
(
2
1
8
5
M
M
)
M
I
N
.
T
O
B
O
T
O
M
O
F
S
H
E
L
F
BOTTOM OF WORKROOM
CEILING IN FOREGROUND
OPEN TO
WORKROOM
A
SECTION A
HOT WATER PIPING AND FLUE.
ENSURE ALL PENETRATIONS
THROUGH SURROUNDING
WALLS AND CEILING ARE
COMPLETELY SEALED.
BO
H
C
E
I
L
I
N
G
H
E
I
G
H
T
P
E
R
P
L
A
N
2"
(
5
0
M
M
)
BOOSTER PUMP
EXTEND BULKHEAD AND BACK
SURROUNDING WALLS TO
STRUCTURE ABOVE
SECTION B
ENSURE WATER TANK CHASE
IS FULLY SEALED FOR PEST
EXCLUSION
3' - 3" (915MM)
8'
-
9
"
(
2
6
7
0
M
M
)
A.
F
.
F
.
NOTES:
1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY.
2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND ADVANSYS
DISHWASHER WHERE ALLOWED BY CODE.
3. POSITION BOOSTER PUMP SO THAT PRESSURE GAUGE IS READABLE AND ACCESSIBLE FOR TROUBLESHOOTING AND MAINTENANCE.
4. BOOSTER PUMP STATIC AND DYNAMIC OUTLET PRESSURE SHALL BE BETWEEN 65 TO 70 PSI. VERIFY PER PUMPS INTEGRAL PRESSURE GAUGE.
5. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES.
6. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED.
7. PROVIDE VIBRATION DAMPENING AT BOOSTER PUMP MOUNT TO PLATFORM.
WATER
HEATER TANK.
SEE WATER
HEATER TANK
DETAIL FOR
MORE
INFORMATION.
GFCI 120V
RECEPTACLE
FOR BOOSTER
PUMP
MIN. CLEAR
2" (50MM)CITY
WATER IN
OUT TO
WATER
FILTRATION
SYSTEM
BOOSTER PUMP.
SECURE TO
SHELF BELOW
WITH BOLTS
THROUGH BASE
PLATE
SHELF PER
ENGINEER'S
DRAWINGS
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
4/
1
5
/
2
0
2
4
1
2
:
1
7
:
5
9
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I505C
76085-018
04-15-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
PLUMBING DETAILS
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
4
-
1
5
-
2
0
2
4
Revision Schedule
Rev Date By Description
3/4" = 1'-0"1SANITIZING (GENERIC) - PLUMBING1/2" = 1'-0"13WATER HEATER TANK CHASE
1" = 1'-0"15BOOSTER PUMP - PLUMBING
NOT USEDNOT USEDNOT USED
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
2301 N Tustin Ave
#A8/22/2024
DOOR LEGEND
SINGLE
IMPACT
DOUBLE
ACTING
SINGLE
FLUSH
INTERIORINTERIOR
WINDOW LEGEND
DRIVE-THRU
WINDOW
OPENING NOT TO
EXCEED 432 SQ.IN.
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
9
/
2
0
2
4
1
0
:
1
2
:
1
1
A
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I601
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
CASEWORK AND FF&E
SCHEDULES
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
SPECIALTY EQUIPMENT SCHEDULE - "E"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
COOLING
10267 2 FRIDGE UNDERCOUNTER 1 DOOR - 27IN 685MM SB MANUF: DELFIELD, MODEL: 400P-STAR2
12618 1 FRIDGE UNDERCOUNTER 1 DOOR WITH SHELF -
27IN 685MM
SB MANUF: TRAULSEN, MODEL: UHT27R0-0300-ZSB02
13620 1 FREEZER REACH IN 1 DOOR LH - 27IN 685MM SB MANUF: TRUE FOOD SERVICE EQUIPMENT, INC.,
MODEL:T-23F-HC-LH STAR
20010 1 FRIDGE NITRO 2 TAP JT NITCOM LH VD KIT INCLUDES UNDERCOUNTER FRIDGE, FONT, TRAY,
AND TUBING
EQUIPMENT
17564 1 BLENDER PITCHER RINSER WITH SENSOR SB MANUF: VITAMIX, MODEL: VM0183
22885 1 BREWER CLOVER VERTICA DOUBLE SB MANUF: DONLIM, MODEL: CM9700
23380 1 BREWER CLOVER VERTICA INSTALL KIT SB MANUF: PENTAIR, MODEL: EV9910-00
23381 1 BREWER CLOVER VERTICA CORD SB MANUF: DONLIM, MODEL: CM9700
23393 3 EQUIPMENT - CBE MILK DISPENSE BRACKET
SLIDE
SB MANUF: DONLIM, MODEL: RE1003-UL
23419 3 MILK DISPENSER SB MANUF: DONLIM, MODEL: RE1003-UL
23442 1 OVEN COMBI SB MANUF: CONVOTHERM, MODEL: CONVOTHERM MINI
EASYTOUCH
23454 1 BOH PARTNER AREA MICROWAVE OVEN - BLACK GC MANUF: PANASONIC, MODEL: NN-SU656B (OR
EQUIVALENT)
FOOD CASE
16238 1 FOOD CASE - ZEPHYR - 66IN 1675MM SB MANUF: STRUCTURAL CONCEPTS, MODEL:
SBZ6652DR
23444 1 FOOD CASE - WARMING WALL - 1000 SQUARE SB MANUF: FLEXESERVE, MODEL: 1000 SQUARE
ICE
19278 2 ICE - BIN DROP IN 45LB 20KG HORIZONTAL SB MANUF: ELKAY, MODEL: CUSTOM ICE BIN
23182 1 ICE - MACHINE HMD1810RBT REMOTE COOLED SB MANUF: FOLLET, MODEL: HMD1810RBT
23421 1 ICE - NUGGET ICE DISPENSER - SINGLE ICE
MACHINE
SB MANUF: FOLLET, MODEL: ID50
23423 1 ICE - NUGGET ICE DIVERTER SB MANUF: FOLLET, MODEL: IMDV-2CM SERIES
23526 1 ICE - BIN ADAPTOR FOLLETT B110H22H30DV
PEDESTAL FOR B110
SB MANUF: FOLLET, MODEL: B110H22H30DV
OTHER
10099 2 RESTROOM TOILET PAPER HOLDER SB MANUF: ASI, MODEL: 0030
10172 2 RESTROOM SEAT COVER DISPENSER SB MANUF: GAMCO, MODEL: TSC-1
10859 2 RESTROOM GRAB BAR - 48IN 1220MM SB MANUF: ASI, MODEL: 3400
10862 2 RESTROOM GRAB BAR - 36IN 915MM SB MANUF: ASI, MODEL: 3400
10947 1 SOAP DISPENSER WALL MOUNTED SB MANUF: GAMCI, MODEL: G-58AP
10977 1 PAPER TOWEL DISPENSER FULL SIZE SB MANUF: GEORGIA PACIFIC, MODEL: 56650A
10992 2 PAPER TOWEL DISPENSER HALF SIZE -
TRANSLUCENT GRAY
GC MANUF: GEORGIA PACIFIC, MODEL: 56640
11115 4 SOAP DISPENSER SINK MOUNTED SB MANUF: GAMCO, MODEL: G-64LB
23420 2 REFRESHER DISPENSE SMALL SB MANUF: WOODMAX, MODEL: WK054
STORAGE
10222 1 WIRE SHELF GRID AT SINK SB MANUF: SPG, MODEL: STBKWT2Y
10416 2 WORKROOM SHELVING - 36IN 915MM SB MANUF: SPG, MODEL: WST966
10462 2 WORKROOM SHELVING POSTS SB MANUF: SPG, MODEL: STBKP86Z4
10698 1 MOP RACK WITH 3 HOLDERS SB MANUF: GAMCO, MODEL: MS-1A
13578 1 DISHWARE DRYING RACK - 21IN 535MM SB MANUF: SPG, MODEL: WMRS-21-KD
21934 1 PASTRY TRAY RACK UNDERCOUNTER - 30IN
760MM
VD MANUF: WIN-HOLT, MODEL AL-1308H-DW-TG
22212 1 WORKROOM SHELVING CART KIT SB MANUF: SPG, MODEL: WST1878C
23445 3 PASTRY COOLING RACK WALL MOUNTED SB MANUF: CHANNEL, MODEL: BUN PAN RACKS
PLUMBING FIXTURE SCHEDULE - "P"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
DRAIN
10594 2 DRAIN - SQUARE - 5IN 125MM GC LOCALLY SOURCED
X10726 8 DRAIN - GRATE HALF SQUARE - 12IN 305MM GC MANUF: ZURN, MODEL: Z1855
FAUCET
10152 2 FAUCET - DOUBLE LABORATORY WITH BENT RISER
SPOUT
SB MANUF: ZURN, MODEL: Z826S1-XL
10153 3 FAUCET - WATER TOWER - 12IN 305MM SB MANUF: CHG, MODEL: KL26-5012-SP
10215 1 FAUCET - DOUBLE LABORATORY WITH SWING
SPOUT
SB MANUF: ZURN, MODEL: Z826F1-XL
10447 1 FAUCET - PRE RINSE SPRAYER WALL MOUNTED SB MANUF: ENCORE, MODEL:
KL53-1000-BLF
10597 2 FAUCET - SINGLE HANDLE SB MANUF: ZURN, MODEL: Z7440-XL
10804 1 FAUCET - PRE RINSE SWING SPOUT SB MANUF: ENCORE, MODEL:
KL55-7012-SE4
10922 1 FAUCET - MOP SINK WALL MOUNTED SB MANUF: ZURN, MODEL: Z843M1
11003 2 FAUCET - METERED SB MANUF: CHICAGO FAUCETS, MODEL:
333-665PSHABCP
13588 1 FAUCET - HAND SINK WALL MOUNTED SB MANUF: ENCORE, MODEL;
KL45-4000-SC4
21352 2 FAUCET - RESTROOM WITH MOTION SENSOR SB MANUF: ZURN, MODEL: Z6955-XL-S
22642 2 FAUCET - INSTANTHOT SYSTEM 2 BUTTON WITH
BOILER AND BRACKET
SB MANUF: MARCO, MODEL: MIX UC3
HOT/ AMBIENT. KIT INCLUDES FONT,
UNDERCOUNTER BOILER AND
BOILER BRACKET FOR SIDE PANEL
MOUNTING. BRACKET CAN BE
FLOOR MOUNTED USING SET OF (4)
STAINLESS STEEL LEGS, ORDERED
SEPARATELY THROUGH VENDOR.
FILTER
23355 1 FILTER - FILTRATION BOOSTER PUMP VD MANUF: GRUNDFOS, MANUF: CMBE
1-75 I-X-C-B-D-E
OTHER
21669 1 GREASE INTERCEPTOR GB75 GC MANUF: SCHIER, MODEL: GB-75
X21676 1 GREASE SAMPLE PORT - SV10 GC MANUF: SCHIER, MODEL: SV-10
SINK
10116 2 SINK - RESTROOM WALL MOUNTED SB MANUF: KOHLER, MODEL: K-2005
10549 2 SINK - RINSE DROP IN SST - 12X20IN 305X510MM SB MANUF: ELKAY, MODEL: P393
10995 1 SINK - MOP - 24X24IN 610X610MM SB MANUF: ZURN, MODEL: Z1996-24
13700 1 SINK - 3 COMP WORK SST - 105IN 2665MM VD MANUF: ELKAY, MODEL:
3C18X20-L20-R26
14688 1 SINK - HAND WITH SIDE SPLASH WALL MOUNTED
SST
SB MANUF: ENCORE, MODEL:
FS17D-1410-05
17565 1 SINK - RINSE WITH DRAINBOARD - 15X27IN
380X685MM
SB MANUF: ELKAY, MODEL: 11232015
22768 2 SINK - COUNTERTOP RINSER WITH WATER TOWER -
26X9IN 660X235MM
SB MANUF: ELKAY, MODEL: OSB216773X
TOILET
11871 2 TOILET - WITH TANK SINGLE FLUSH GC MANUF: PROFLO, MODEL:
PF1601PAWH
DATA DEVICE SCHEDULE - "A"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
AUDIO VISUAL
10015 2 SPEAKER RECESSED - WHITE VD
19493 4 SPEAKER PENDANT MOUNTED - BLACK VD
DATA
20294 1 IOT MODULE SB
MENU BOARD
22970 4 MENU BOARD - DIGITAL MENU BOARD - 44X25.25IN 1121X644MM - BLACK VD
22972 1 MENU - DMB SCREEN MOUNTING BRACKET VD
23021 1 MENU BOARD - ORDER STATUS BOARD MOUNTING BRACKET - BLACK VD
LIGHTING FIXTURE SCHEDULE - "L"
DESIGN ID COUNT DESCRIPTION FURN. BY
INST.
BY BULB COMMENTS
PENDANT
20661 3 PENDANT - ANDLIGHT SPOTLIGHT VOLUMES - BLACK VD AS PACKAGED: 1X LED G25
6.5W (DOWN); 1X LED A15
4.5W (UP)
UPLIGHT:C
DOWNLIGHT:C
20662 1 PENDANT - ANDLIGHT SPOTLIGHT VOLUMES - SAGE VD INTEGRATED LED UPLIGHT:C
DOWNLIGHT:B
RECESSED CAN
21772 54 CAN - LED ADJUSTABLE RECESSED - 3IN 75MM - WHITE
- 800LM FLOOD
VD INTEGRATED LED
21774 12 CAN - LED ADJUSTABLE RECESSED - 3IN 75MM - WHITE
- 700LM WF
VD INTEGRATED LED
21776 6 CAN - LED WALL WASH - 3IN 75MM - WHITE - 1000LM VD INTEGRATED LED
SCONCE
20748 2 SCONCE - KUZCO PLUTO TRIPLE - CHROME VD INTEGRATED LED
STRIP
22215 1 STRIP - LED TAPE IN HOUSING - VARIABLE LENGTH -
BLACK - 350LM PER FT
VD INTEGRATED LED FIELD TRIMMABLE TO
0.9IN LENGTHS
22216 1 STRIP - LED TAPE IN HOUSING - VARIABLE LENGTH -
WHITE - 350LM PER FT
VD INTEGRATED LED FIELD TRIMMABLE TO
0.9IN LENGTHS
22220 4 STRIP - LED TAPE GRAZER - VARIABLE LENGTH -
WHITE - 700LM PER FT
VD INTEGRATED LED FIELD TRIMMABLE TO
6IN LENGTHS
TRACK
19409 5 TRACK - WITH CONNECTORS - 4FT 122CM - BLACK - 2
CIRCUIT
VD JUNO; TU-4FT-BL
19411 1 TRACK - WITH CONNECTORS - 8FT 244CM - BLACK - 2
CIRCUIT
VD JUNO; TU-8FT-BL
21779 9 TRACK - LED FIXTURE WITH SNOOT - 3IN 75MM -
BLACK - 1100LM FLOOD
VD INTEGRATED LED
TROFFER
21783 7 TROFFER - LED RECESSED - 24X48IN 600X1200MM -
WHITE - 4300LM
VD INTEGRATED LED
MECHANICAL EQUIPMENT SCHEDULE - "M"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
FAN
10721 1 FAN - DT AIR CURTAIN - 22IN 560MM GC INCLUDE AS PART OF DT WINDOW
PACKAGE
DOOR SCHEDULE - "D"
DESIGN ID MARK DESCRIPTION WIDTH HEIGHT
HARDWARE
SET FURN BY INST BY COMMENTS
Interior
10190 09 DOOR - SINGLE FLUSH - 36IN 3' - 0" 7' - 0" 7-A GC FRAME FINISH:
SW7031, DOOR
FINISH: WD0073
10190 16 DOOR - SINGLE FLUSH - 36IN 3' - 0" 7' - 0" 6 GC FRAME FINISH:
SW7031, DOOR
FINISH: WD0073
10086 08 DOOR - SINGLE IMPACT DOUBLE ACTING -
36IN 915MM
3' - 0" 7' - 0" 11 GC FRAME FINISH:
SW7103, DOOR
FINISH: PL0027
3
1 Stop & Holders 473 Door Stop w/ Hook Rockwood 626
3 Accessories GJ64 Rubber Silencer Glynn Johnson Gray
2 Protective Trim Units K1050 B4E Kickplate 8" x 34" Each Side 32D Rockwood 630
1 Closing Devices 8916 Door Closer 8916 F89P Dorma 626
1 Securing Devices C607 7-Pin Core Combination "A" Keyway Falcon Lock 626
1 Alarm Lock CO-100 Privacy Keypad Schlage 626
3 Hanging Devices TA2714/MPB79 Hinge MacPro Bearing 5 x 4.5 McKinney 626
No. Item Description Manufacturer Finish
DOOR HARDWARE SET NO. 7-A - For restroom door with cipher lock
1 Stops and Holders 473 Door Stop w/ Hook Rockwood 626
3 Accessories GJ64 Rubber Silencer Glynn Johnson Gray
2 Protective Trim Units K1050 B4E Kickplate 8" x 34" Each Side 32D Rockwood 630
1 Closing Devices 8916 Door Closer 8916 AF89P Dorma 689
1 Securing Devices PB5425LN Lock, Shallow Coin Turn,
Privacy PB5425LN-693-497 1-3/4 Yale Lock 626
3 Hanging Items TA2714/MPB79 Hinge MacPro Bearing 5 x 4.5 McKinney 626
No. Item Description Manufacturer Finish
DOOR HARDWARE SET NO. 6 - For restroom door with lever and privacy lock
1 Traffic Door Package SCP8 36" x 84" Eliason As Selected
No. Item Description Manufacturer Finish
DOOR HARDWARE SET NO. 11 - For workroom door at backbar
WINDOW SCHEDULE
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY Finish COMMENTS
WINDOW
21987 1 WINDOW - DT BI-PARTING RESTRICTED
OPENING - 54X52IN - WITH AIR CURTAIN
& TRANSOM
GC MANUF: READY ACESS,
MODEL: WC14X29131,
FINISH: BLACK
BARRIER FREE DOOR HARDWARE SCHEDULE - "D"
DESIGN ID COUNT DESCRIPTION FURN BY INST BY COMMENTS
23130 1 DOOR - BARRIER FREE HARDWARE ACTUATOR
BOLLARD
VD
23131 1 DOOR - BARRIER FREE HARDWARE ACTUATOR WALL
MOUNT
VD
23129 1 DOOR - BARRIER FREE HARDWARE KEY SWITCH VD
23135 1 DOOR - BARRIER FREE HARDWARE OPERATOR -
BLACK
VD
FURNITURE SCHEDULE - "F"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
CHAIR
21456 4 CHAIR - CAFE ASHER UPHOLSTERED BACK - WHITE OAK AND
CARAMEL BROWN NATURAL WD0073 F0008
VD
23062 4 CHAIR - CAFE PEGGY UPHOLSTERED - WHITE OAK AND SEAFOAM
GREEN WD0073 F0243
VD
TK0077 1 CHAIR - MANAGERS WORKSTATION SB STEELCASE SERIES
ONE ARMLESS
DESK
TK0053 1 DESK - MANAGERS WORKSTATION SHELVES - 48IN 1220MM SB
TK0076 1 DESK - MANAGERS WORKSTATION - 48X24X27IN 1220X610X685MM SB
MIRROR
10093 2 MIRROR - RESTROOM - 18X30IN 455X760MM GC
TK0050 1 MIRROR - BOH - 16X51IN 405X1295MM VD
OTHER
10756 2 COAT HOOK 1 PRONG SQUARE - 2IN 50MM - SST SB
19620 3 ACOUSTICAL BAFFLE SYSTEM - 106X48IN 2690X1220MM -
TRAVERTINE DARK
GC TRAVERTINE DARK
TK0051 1 COAT HOOK STRIP - 30IN 760MM VD BLACK FINISH
X19620 6 ACOUSTICAL BAFFLE SYSTEM - 106X48IN 2690X1220MM -
TRAVERTINE DARK
GC TRAVERTINE DARK
STORAGE
TK0078 1 FILE MOBILE PEDESTAL WITH CUSHION AND LOCK VD
TK0079 1 MANAGERS DESK CART - 24X20IN 610X510MM VD
TABLE
18468 2 TABLE - BASE CAFE T LEG - HOT ROLLED STEEL MT0011 VD
21449 5 TABLE - BASE CAFE HEIGHT BOTTLE - FLAT BLACK MT0028 SB
21474 1 TABLE - BASE ACCESSIBLE POST LEG RECTANGULAR - FLAT
BLACK MT0028
VD
21788 1 TABLE - TOP ACCESSIBLE FOR POST LEG RECTANGULAR -
40X24IN 1015X610MM - WHITE OAK WD0073
VD
21800 1 TABLE - TOP ACCESSIBLE ROUND EDGE OBLONG - 48X24IN
1220X610MM - WHITE OAK WD0073
VD
21842 5 TABLE - TOP ROUND EDGE ROUND - 24IN 610MM - WHITE OAK
WD0073
SB
WINDOW TREATMENT
X22488 8 ROLLER SHADE - U59 ALABASTER VD MANUF:
ROLL-A-SHADE,
MODEL: SHEER
WEAVE - U59
ALABASTER
GRAPHICS AND ARTWORK SCHEDULE - "G"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
GRAPHICS - ARTWORK
21491 1 ART - BRIDGET SHILLING - PICKING COFFEE VD 1’ - 10” X 2’ – 6” WOOD FRAME
AROUND THE ARTWORK – WD0073.
FRAME WIDTH: 3”, FRAME DEPTH:
1”. FOR MORE INFOTMATION
REFER TO INTERIOR ELEVATION
SHEETS.
22043 1 ART - BRIDGET SHILLING - COFFEE AND THE
TANAGER
VD 1’ - 10” X 2’ – 6” WOOD FRAME
AROUND THE ARTWORK – WD0073.
FRAME WIDTH: 3”, FRAME DEPTH:
1”. FOR MORE INFOTMATION
REFER TO INTERIOR ELEVATION
SHEETS.
22922 1 ART - JORDAN KAY - FRUITING COFFEE
BRANCH 2 - PAINTABLE
VD ARTWORK DESIGNED TO BE HAND
PAINTED ON THE WOOD CLADDING.
WD0073-MAD101
X22178 1 ART - MARIA CAMILA BERNAL TORO -
COLOMBIA STORY
VD WRAPPED CANVAS IN FLOAT
FRAME 1” THICK - WD0073. REFER
TO SHEET I204 FOR OVERALL
DIMENSIONS.
GRAPHICS - OTHER
23136 1 AUTOMATIC DOOR CAUTION SIGNAGE VD
TK0074 2 RESTROOM SIGN GENDER NEUTRAL
ACCESSIBLE
VD
EXTERIOR SIGNAGE SCHEDULE - "S"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY BULB COMMENTS
SIGNAGE - DRIVE THRU
22544 1 SIGN - DT CLEARANCE BAR SQUARE FRAME
FREESTANDING - BLACK AND DARK GREEN
VD
23071 1 SIGN - DIRECTIONAL EXIT ONLY ILLUM DS -
EXG FOUNDATION - 44IN 1120MM
VD
23077 2 SIGN - DT DIRECTIONAL ARROW ILLUM DS -
EXG FOUNDATION - 44IN 1120MM
VD
SITE SCHEDULE - "Y"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
FENCE AND RAILING
19581 1 QUEUE RAIL WOOD DOUBLE - WHITE OAK
WD0073
VD
OTHER
23113 1 GROUND GRAPHICS DT ENTRY STENCIL VD REFERENCE PAINT 20511 FOR
SPECIFICATIONS
23115 1 GROUND GRAPHICS DO NOT ENTER STENCIL VD REFERENCE PAINT 20511 FOR
SPECIFICATIONS
23117 8 GROUND GRAPHICS ARROW STENCIL VD REFERENCE PAINT 20511 FOR
SPECIFICATIONS
FRAME FINISH:
SW7741, DOOR
FINISH: WD0073
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
A
2301 N Tustin Ave
#A8/22/2024
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
7/
5
/
2
0
2
4
1
0
:
2
3
:
1
4
A
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
T
u
s
t
i
n
&
S
a
n
t
a
C
l
a
r
a
5
1
9
6
9
\
C
D
\T
u
s
t
i
n
a
n
d
S
a
n
t
a
C
l
a
r
a
-
R
e
v
i
t
M
o
d
e
l
.
r
v
t
I602
76085-018
07-02-2024
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
INTERIOR FINISHES
SCHEDULES
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
CASEWORK FINISH SCHEDULE
ENGINE ZONE MATERIAL DESCRIPTION FINISH CODE COMMENTS
COMPOSITE - WHISPER
COUNTERTOPS - BACKBAR COMPOSITE - WHISPER CP0030
COUNTERTOPS - ESPRESSO COMPOSITE - WHISPER CP0030
COUNTERTOPS - FRONTBAR COMPOSITE - WHISPER CP0030
COUNTERTOPS - SHROUD COMPOSITE - WHISPER CP0030
METAL - FLAT BLACK POWDERCOAT
CABINETS - DOOR PULL METAL - FLAT BLACK POWDERCOAT MT0028
METAL - STAINLESS STEEL - BRUSHED
COUNTERTOPS - HAND SINK METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED
16GA
PLAM - GOLDEN BLONDE GRAIN
CABINETS - UPPER PLAM - GOLDEN BLONDE GRAIN PL0027
PLAM - GRAPHITE
CABINETS - UNDERCOUNTER PLAM - GRAPHITE PL0003
CABINETS - UPPER PLAM - GRAPHITE PL0003
WOOD - WHITE OAK - FLUTED - VERTICAL
FINISH PANELS - FRONTBAR WOOD - WHITE OAK - FLUTED - VERTICAL WD0073
MAD303-V
CASEWORK SCHEDULE - "C"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
X1002 1 PARTNER REST AREA - UPPER CUBBIES - PL0027 CW
X1005 1 1/8" X 1/8" METAL TRIM - MT0029 CW
X1007 1 WOOD CLADDING - WD0073/MAD 101 CW
X1009 1 1"X1" METAL TRIM - MT0029 CW
BANQUETTE
TK0001 4 BANQUETTE - ORION CW REFER TO SHEET I502C FOR
DIMENSIONS - FABRIC: F0243,
BASE MATERIAL: MT0028
TKX001 1 BANQUETTE - ORION - CORNER CW GC REFER TO SHEET I502C FOR
DIMENSIONS - FABRIC: F0243,
BASE MATERIAL: MT0028
CABINET
17573 6 CABINET - BACKBAR COUNTER SUPPORT PANEL
- 3IN 75MM
CW
17574 3 CABINET - BACKBAR SINK OR ICE - 15IN 380MM CW
17740 2 CABINET - BACKBAR - 30IN 760MM CW
17741 4 CABINET - BACKBAR 15IN 380MM CW
17743 1 CABINET - DT POS - 30IN 760MM CW
17744 1 CABINET - FRONTBAR POS BRIDGE - 22IN 560MM CW
17745 1 CABINET - BACKBAR DRAWER - 15IN 380MM CW
17747 6 CABINET - BACKBAR TRASH - 15IN 380MM CW
17896 1 CABINET - BACKBAR CUBBY - 15IN 380MM CW
19343 1 CABINET - CORNER FIT KIT CW
21190 1 CABINET - FRONTBAR TRASH - 15IN 380MM CW
21191 3 CABINET - FRONTBAR DRAWER - 15IN 380MM CW
21192 2 CABINET - FRONTBAR POS - 30IN 760MM CW
23388 1 CABINET - BACKBAR - 18IN 460MM CW
23426 1 CABINET - WRM LOW - 30IN 760MM CW
X17741 3 CABINET - BACKBAR 15IN 380MM CW
CABINETS
X23709 1 CABINET - CBE UPPER CASEWORK IN-LINE - LF -
82IN
CW
CAFE
20369 1 WALL BAY 3 UNIT - 90IN 2285MM - WHITE OAK
WD0073
VD
23964 1 WASTE AND RECYCLE STATION THREE DROP -
GOLDEN BLONDE AND WHITE PL0027 CP0002
SB
COUNTERTOP
17807 2 COUNTERTOP - BACKBAR - 15IN 380MM CW
17810 2 COUNTERTOP - HAND SINK WITH TALL SPLASH
STAINLESS - 15IN 380MM
CW
17830 1 COUNTERTOP - POS - 82IN 2085MM CW
18720 1 COUNTERTOP - BREW WITH TRASH DROP - LF -
90IN 2285MM
CW
18883 1 COUNTERTOP - END CAP SQUARED - RF CW
20061 1 COUNTERTOP - ESPRESSO METRO - RF - 139IN
3530MM
CW
20063 1 COUNTERTOP - FRONTBAR CAP - 139IN 3530MM CW
20271 1 COUNTERTOP - FRONTBAR MOP PLANAR - 60IN
1525MM
CW
21958 1 COUNTERTOP - DT WARMING - RF - 93IN 2360MM CW
23151 1 COUNTERTOP - PARTNER AMENITY - 67IN
1700MM
CW
23409 1 COUNTERTOP - CBE IN-LINE LF - 138IN 3505MM CW
23433 1 COUNTERTOP - WRM RF - 79IN 1930MM CW
X17827 1 COUNTERTOP - DT POS - RF - 78IN 1980MM CW
DIEWALL
17831 1 DIEWALL - POS - 82IN 2085MM CW
18865 1 DIEWALL - 60IN 1525MM CW
18884 1 DIEWALL - END CAP - RF CW
20064 1 DIEWALL - ESPRESSO - 139IN 3530MM CW
FIT KIT
17894 3 FIT KIT - CABINET FILLER PANEL CW
X17895 1 FIT KIT - BACKBAR COUNTERTOP CW
OTHER
11155 2 ESPRESSO MACHINE PUMP MOUNT - 10X10IN
255X255MM
CW
18145 4 COUNTERTOP SUPPORT LEG CW
20066 1 SHROUD - 139IN 3530MM CW
20067 1 SNEEZE GUARD - 139IN 3530MM CW
20633 5 COUNTERTOP SUPPORT LEG SLIM CW
PANEL
17832 1 PANEL - 82IN 2085MM CW
18717 1 PANEL - 60IN 1525MM CW
18885 1 PANEL - END CAP - RF CW
20065 1 PANEL - 139IN 3530MM CW
UPPER CUBBY
X0017 1 DRIVE-THRU UPPER CABINET - ALT 3 CW
WALL TREATMENT (AREA) SCHEDULE - "Q"
DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS
17778 110 SF WALL TEXTURE - TEXTURGLAS - TG21
HERRINGBONE + SW7741
VD DESIGNER TO SPECIFY PAINT COLOR
17778 157 SF WALL TEXTURE - TEXTURGLAS - TG21
HERRINGBONE + SW7749
VD DESIGNER TO SPECIFY PAINT COLOR
PLASTIC
11469 1319 SF FRP - WHITE GC
TILE
22817 718 SF TILE - MOSA - UNBLEACHED WHITE - 4X12IN
100X300MM
VD GROUT: MAPEI - 11 SAHARA BEIGE, OR EQUAL
FLOOR TREATMENT SCHEDULE - "T"
DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS
PLASTIC
19795 897 SF POLYVINYL FLOOR TILE - ECO-GRIP -
PEWTER
GC GC TO PROCURE FROM ALLIED INDUSTRIES
TILE
20259 269 SF TILE - VENICE VILLA - IVORY - 24X24IN
600X600MM
VD GROUT: MAPEI - 44 PALE UMBER, OR EQUAL
20262 561 SF TILE - FRENCH CLAY - CAFE - 24X24IN
600X600MM
VD GROUT: MAPEI - 09 GREY, OR EQUAL
WALK OFF MAT
19288 7 SF WALK OFF MAT - HELIX Z1 - BLACK - 12X9IN
305X230MM
VD
19289 17 SF WALK OFF MAT - HELIX Z2 - BLACK AND
GUNMETAL - 12X9IN 305X230MM
VD CANNOT BE CUT TO SIZE; USE HELIX Z1 AS BORDER
WHEN FULL TILES CANNOT BE PLACED
WALL BASE SCHEDULE - "B"
DESIGN ID LENGTH DESCRIPTION FURN. BY INST. BY COMMENTS
TILE BASE
18735 192' - 4" TILE BASE - PLAZA NOVA - WHITE IMAGE -
6X12IN 150X300MM
VD GROUT: DESIGN TO SPECIFY
X19795 306' - 10
3/4"
ECOGRIP 6" BASE GC POLYVINYL ECOGRIP FLOORING TO WRAP UP 6" ON
WALLS AND CABINETS WITH 3/8" COVE RADIUS AND
HEAT WELDED SEAMS
PAINT SCHEDULE
DESIGN ID DESCRIPTION LRV FURN. BY INST. BY COMMENTS
SW7031 SW7031 MEGA GREIG 37 GC SW USE PRIMER CP-1; NCS - S 3005-Y50R; AKZO
NOBEL - 20YY 37/094
SW7103 SW7103 WHITETAIL 86 GC SW USE PRIMER CP-2; NCS - S 6005-G80Y; AKZO
NOBEL - 30YY 14/070
SW7741 SW7741 WILLOW TREE 41 GC
SW7749 SW7749 LAUREL WOODS 6 GC DESIGNER TO SPECIFY PAINT COLOR
CEILING TREATMENT SCHEDULE - "U"
DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS
MISCELLANEOUS
11302 476 SF ACT VlNYL - 2' X 4' GC MANUF: ARMSTRONG, MODEL:
CLEANROOM VL-870
SITE SCHEDULE - "Y"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
FENCE AND RAILING
19581 1 QUEUE RAIL WOOD DOUBLE - WHITE OAK
WD0073
VD
OTHER
23113 1 GROUND GRAPHICS DT ENTRY STENCIL VD REFERENCE PAINT 20511 FOR
SPECIFICATIONS
23115 1 GROUND GRAPHICS DO NOT ENTER STENCIL VD REFERENCE PAINT 20511 FOR
SPECIFICATIONS
23117 8 GROUND GRAPHICS ARROW STENCIL VD REFERENCE PAINT 20511 FOR
SPECIFICATIONS
Revision Schedule
Rev Date By Description
A 06-13-24 SS 1st Round Comments
A
2301 N Tustin Ave
#A8/22/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
76085-018
<XX-XX-XXXX>
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
Revision Schedule
Rev Date By Description
E001
ELECTRICAL
NOTES
SECURITY SYSTEM NOTES
A.STARBUCKS CONTRACTS DIRECTLY WITH SECURITY VENDOR TO SUPPLY AND
INSTALL THE SECURITY SYSTEM. CONTRACTOR TO SCHEDULE INSTALLATION OF
SECURITY SYSTEM FOR FOUR (4) TIMES;
1.MEET TO PLAN SECURITY CABLE PULL WITH SECURITY CABLE INSTALLER
PRIOR TO DRYWALL INSTALLATION.
2.SECURITY CABLE INSTALLER PULLS SECURITY CABLES, MOUNTS PANEL,
KEYPAD AND SENSORS.
3.SECURITY EQUIPMENT INSTALL OF CAMERA, NVR AND MONITOR.
4.SECURITY MONITORING COMPANY TO BRING SYSTEM ONLINE AND TRAIN
PARTNERS AFTER POS INSTALL
B.SECURITY VENDOR REQUIRES A MINIMUM TWO (2) WEEKS LEAD TIME FOR EACH
INSTALLATION. SECURITY VENDOR WILL COORDINATE REGIONAL INSTALLERS. ALL
ADDITIONAL EXPENSES INCURRED DUE TO THE CONTRACTOR'S FAILURE TO
SCHEDULE ACCORDINGLY WILL BE THE RESPONSIBILITY OF THE CONTRACTOR.
TELEPHONE SYSTEM NOTES
A.IF ADDITIONAL TELEPHONE LINES ARE REQUIRED BEYOND THE STANDARD SINGLE
LINE (SUCH AS FOR A FIRE ALARM) THE GENERAL CONTRACTOR SHALL CONTACT
STARBUCKS PRIOR TO BEGINNING CONSTRUCTION TO ORDER THE ADDITIONAL
TELEPHONE LINE(S). REPORT ANY TELEPHONE INSTALLATION ISSUES IMMEDIATELY
TO STARBUCKS.
B.CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT THERE ARE EXISTING,
WORKING TEL FACILITIES TO THE BUILDING OR THAT LANDLORD HAS FURNISHED
AND INSTALLED ONE (1) 2" (51MM) MIN. (ENTRANCE) CONDUIT INCLUDING PULL
STRING FROM TELCO STREET FEED LINE TO THE BUILDING AS IDENTIFIED BY THE
PHONE COMPANY. NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY IF
FACILITIES OR CONDUIT AND PULL STRING ARE NOT INSTALLED.
C.GENERAL CONTRACTOR IS TO ENSURE THAT THERE IS A 2" (51MM) MIN. CONDUIT
WITH PULL STRING FROM THE DATA RACK TO THE DEMARC (TELCO TO CUSTOMER
HAND OFF EQUIPMENT) WHEN THE DEMARC IS MORE THAN 10' FROM THE DATA
RACK. DISTANCES LESS THAN 10' WILL NOT REQUIRE CONDUIT.
D.ALL TELEPHONE/NETWORK CABLING IS THE SCOPE OF WORK OF THE TELEPHONE/
NETWORK CABLING VENDOR.
POS/ DATA LINE NOTES
A.STARBUCKS CONTRACTS DIRECTLY WITH THE DATA CABLING VENDOR TO SUPPLY
AND INSTALL CATEGORY 5e (CAT5e) LAN CABLE AND CONNECTORS FOR THE POINT
OF SALE (POS) SYSTEMS. CONTRACTOR TO SCHEDULE INSTALLATION OF DATA
CABLING WITH DATA CABLING VENDOR. DATA CABLING VENDOR REQUIRES A LEAD
TIME FOR INSTALLATION. DATA CABLING VENDOR WILL COORDINATE REGIONAL
INSTALLERS.
B.AT THE START OF CONSTRUCTION, STARBUCKS CONSTRUCTION MANAGER
SCHEDULES DELIVER OF CASH REGISTER/MANAGER'S WORKSTATION EQUIPMENT
AND INSTALLATION BY A POS INSTALL TECHNICIAN FOR ONE (1) MONTH PRIOR TO
STORE OPEN. CONTRACTOR TO VERIFY DELIVERY SCHEDULE TWO (2) WEEKS PRIOR
TO DELIVERY AND INSTALLATION DATE. EQUIPMENT IS SHIPPED DIRECTLY TO THE
STORE. CONTRACTOR TO ACCEPT POS EQUIPMENT DELIVERY. DO NOT REFUSE
DELIVERY.
C.DATA CABLING TECHNICIAN TO PROVIDE ALL CAT5e LAN CABLING AND
CONNECTORS FROM ALL DESIGNED AND FUTURE CASH REGISTER LOCATIONS,
MANAGER'S WORKSTATION, ALL OTHER NETWORKED EQUIPMENT (CUP LABELERS,
CLOVER, BUMP BAR, ETC...) AND WIRELESS ACCESS POINT TO THE DATA RACK
AREA. CONTRACTOR IS TO HAVE CONDUIT WITH PULL STRING IN PLACE FOR ALL
CABLE RUNS PRIOR TO CABLE INSTALL DATE.
D.STARBUCKS NEW STORE GROUP IS RESPONSIBLE FOR COORDINATING STARBUCKS
POS SYSTEMS DELIVERY AND INSTALLATION WITH THE POS VENDOR. THIS GROUP
MAY BE CONTACTED AT: NEWSTORES@STARBUCKS.COM.
COMMUNICATION SYSTEM NOTES
A.CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT THE LANDLORD HAS
FURNISHED AND INSTALLED ONE (1) ADDITIONAL 2" (51MM) (ENTRANCE) CONDUIT
INCLUDING PULL STRING (FOR A TOTAL OF TWO (2)) FROM THE STREET FEED TO
THE BUILDING AS IDENTIFIED BY THE INTERNET SERVICE PROVIDER.
FIRE ALARM SYSTEM NOTES
A.IF STARBUCKS IS REQUIRED TO PROVIDE A FIRE ALARM AND/OR FIRE ALARM
MONITORING AND/OR PHONE LINES FOR A FIRE ALARM, AS SPECIFIED IN THE LEASE
AGREEMENT, THE CONTRACTOR IS TO NOTIFY GNOC IMMEDIATELY THAT FIRE
ALARM LINES ARE NEEDED. STARBUCKS PREFERRED FIRE ALARM SERVICE
PROVIDER, STANLEY, IS TO BE CONTACTED BY THE CONSTRUCTION MANAGER TO
INSTALL FIRE ALARM PANEL AND/OR MONITORING SERVICE AS REQUIRED.
WIRELESS NETWORK NOTES
A.CABLING FOR INTERNET SERVICE SHALL BE FURNISHED AND INSTALLED BY THE
VENDOR FOR FIBER OR BROADBAND CONNECTIONS. T1 AND ETHERNET EXTENSION
CABLING IS PROVIDED BY THE STARBUCKS (TELEPHONE/ NETWORK) CABLING
VENDOR. COORDINATE WITH STARBUCKS.
MUSIC SYSTEM NOTES
A.PROVIDE AND INSTALL A COMPLETE WIRING SYSTEM FOR ALL SPEAKERS.
CONNECT ALL SPEAKERS TO THE OWNER PROVIDED MUSIC SYSTEM.
MOUNT OWNER FURNISHED SPEAKERS WHERE SHOWN ON INTERIOR
REFLECTED CEILING PLAN AND IN COORDINATION WITH ALL PLANS AND
DETAILS. FOLLOW MANUFACTURER'S INSTALLATION REQUIREMENTS.
CONTROLS AND OPERATION
A.COORDINATE INSTALLATION OF LIGHTING CONTROL PANEL (IF APPLICABLE)
AND ENERGY MANAGEMENT SYSTEM (EMS) WITH ENERGY MANAGEMENT
SYSTEM VENDOR.
B.FURNISH AND INSTALL RACEWAYS WITH PULLSTRINGS AND JUNCTION BOXES
TO SUPPORT VENDOR’S WORK.
C.COORDINATE WITH VENDOR AND PLANS FOR DEVICE LOCATIONS.
GENERAL ELECTRICAL NOTES
A.THE ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL WORK AND
SPECIFICATIONS WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS AND
SPECIFICATIONS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOT
SCALE DISTANCES OFF THE ELECTRICAL DRAWINGS; USE ACTUAL BUILDING
DIMENSIONS. OVERALL CASEWORK COMPONENT DIMENSIONING ON ELECTRICAL
DETAILS ARE SHOWN FOR REFERENCE AND COORDINATION ONLY. SEE
SPECIFICATION SHEETS FOR ELECTRICAL SPECIFICATIONS.
B.ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE
ALL BRANCH CIRCUIT LOADS BETWEEN THE PHASES OF THE SYSTEM WITHIN 10%
OF THE HIGHEST PHASE LOAD IN EACH PANEL BOARD.
C.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DE-ENERGIZING
CIRCUITS IN DEMOLITION AREAS TO INSURE A SAFE CONDITION. ELECTRICAL
DEVICES AND ASSOCIATED WIRING LOCATED WITHIN THE DEMOLITION AREA THAT
WILL NO LONGER BE USED SHALL BE REMOVED AND PROPERLY DISPOSED OF AT
CONTRACTORS EXPENSE UNLESS OTHERWISE NOTED.
D.THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALL ELECTRICAL SYSTEM
OUTAGES WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN
ADVANCE. UNLESS APPROVED OTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN
11:00PM AND 5:00AM.
E.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY CONDUIT
AND J-BOXES TO SUPPORT A COMPLETE SECURITY, PHONE, POS AND DATA
SYSTEMS. SEE MANAGER WORKSTATION AND BAR POINT OF SALE (POS)
POWER/TELECOM/SECURITY DIAGRAM. COORDINATE ALL DEVICE LOCATIONS AND
MOUNTING HEIGHTS WITH SECURITY VENDOR PRIOR TO ROUGH-IN. PROVIDE
END-TO-END PULL STRINGS IN ALL CONDUITS. LABEL EACH END OF THE PULL
STRING WITH CONDUIT SYSTEM ("SECURITY") AND DESTINATION ("CAFÉ", "FRONT
BAR", ETC.). PROVIDE INSULATED BUSHINGS ON ALL STUBBED-UP AND EXPOSED
CONDUIT ENDS.
F.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR
TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER
SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE
COURSE OF WORK.
G.EXPOSED/SURFACE MOUNTED CONDUITS SHALL ONLY BE ALLOWED WHERE
NECESSARY IN EXPOSED CEILING AREAS. IF CONDUITS NEED TO BE SURFACE
MOUNTED TO WALLS, COORDINATE WITH STARBUCKS CONSTRUCTION MANAGER
FOR APPROVAL.
H.VERIFY LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECTURAL
DRAWINGS, INTERIOR DETAILS, FINISH SCHEDULES, GENERAL CONTRACTOR,
EQUIPMENT VENDORS, STARBUCKS AND EXISTING SITE CONDITIONS. VERIFY FINAL
DOOR HINGE LOCATION PRIOR TO SWITCH INSTALLATION AND ADJUST SWITCH
LOCATION IF NEEDED. DO NOT MOUNT RECEPTACLES/SWITCHES IN LOCATIONS
THAT WOULD CONFLICT WITH MIRRORS, SEAMS OF WALLS, WAINSCOTS, TILE
TRANSITIONS, ETC.
GENERAL NOTES
SCOPE
THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A
COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL
CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL, AND
EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK.
SITE EXAMINATION
THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS
WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL
REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER
INSTALLATION OF THE ELECTRICAL WORK.
STANDARDS
EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE
PROVISIONS OF CSA, ULC, NEC, ASTM, UL, ETL, NEMA, ANSI, AS APPLICABLE
TO EACH INDIVIDUAL UNIT OR ASSEMBLY.
CODES
ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL
APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE OF
CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE CODES,
THE HIGHEST STANDARD SHALL APPLY. ELECTRICAL CONTRACTOR SHALL
SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY
EXTRA COST TO STARBUCKS.
PERMITS AND FEES
THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS,
FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL WORK.
WARRANTY
THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL
WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A
PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY
STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK
PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING
WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND
WORKMANSHIP.
STANDARD ABBREVIATIONS
AFF
AHJ
APPROX
ABOVE FINISHED FLOOR
AUTHORITIES HAVING JURISDICTION
APPROXIMATE
BLDG BUILDING
CKT
CLG
CM
CONST
CW
CXA
CIRCUIT
CEILING
STARBUCKS CONSTRUCTION MANAGER
CONSTRUCTION
COLD WATER
COMMISSIONING AGENT
DEG
DL
DM
DN
DTL
DWG(S)
DEGREES
LIGHTS WITHIN DAYLIGHT ZONE
STARBUCKS DESIGN MANAGER
DOWN
DETAIL
DRAWING(S)
EA
EC
ECP
EG
ELEC
EM
EMS
EXIST
EXT
EACH
ELECTRICAL CONTRACTOR
EQUIPMENT CONTROL PAC
EXHAUST GRILLE
ELECTRICAL
EMERGENCY
ENERGY MANAGEMENT SYSTEM
EXISTING
EXTERIOR
F&I
FLR
FT
FURNISH & INSTALL
FLOOR
FOOT/FEET
GC
GFCI
GND
GENERAL CONTRACTOR
GROUND FAULT CIRCUIT INTERRUPTER
GROUND
HR
HVAC
HW
HOUR
HEATING, VENTILATION, AIR CONDITIONING
HOT WATER
LCP
LL
LS
LV
LIGHTING CONTROL PANEL
LANDLORD
LIGHT SENSOR PHOTOCELL
LOW VOLTAGE
MAX
MC
MDP
MECH
MEP
MFG
MIN
MAXIMUM
MECHANICAL CONTRACTOR
MAIN DISTRIBUTION PANEL
MECHANICAL
MECHANICAL, ELECTRICAL, AND PLUMBING
MANUFACTURER
MINIMUM
NL
NTS
NIGHTLIGHT
NOT TO SCALE
OCP OVERCURRENT PROTECTION
REF
REQ(’D)
REV
REFERENCE
REQUIRE(D)
REVISION
SF
SHT
SPECS
SST
SQUARE FEET
SHEET
SPECIFICATION(S)
STAINLESS STEEL
TEL
TEMP
TYP
TELEPHONE
TEMPORARY
TYPICAL
UNO UNLESS NOTED OTHERWISE
WH
WP
WATER HEATER
WEATHER PROOF
ELECTRICAL SYMBOL LEGEND
SYMBOL DESCRIPTION
POWER
DUPLEX RECEPTACLE, WALL MOUNTED
DUPLEX RECEPTACLE, WALL MOUNTED, SPLIT-WIRED OCCUPANCY SENSOR
CONTROLLED/SWITCHED
DUPLEX RECEPTACLE, WALL MOUNTED, ISOLATED GROUND
DUPLEX RECEPTACLE, WALL MOUNTED ABOVE COUNTER
DUPLEX GFCI RECEPTACLE, WALL MOUNTED
DUPLEX GFCI RECEPTACLE, WALL MOUNTED ABOVE COUNTER
DUPLEX RECEPTACLE, WALL MOUNTED WITH TWO 5V USB CHARGING PORTS
DOUBLE DUPLEX RECEPTACLE, WALL MOUNTED
DOUBLE DUPLEX GFCI RECEPTACLE, WALL MOUNTED
DUPLEX RECEPTACLE, FLUSH IN CEILING
SPECIAL OUTLET: 20A, 250V, 2P, 3-WIRE NEMA 6-20R
SPECIAL OUTLET: 30A, 125V, 1P, 3-WIRE NEMA 5-30R
SPECIAL OUTLET: 30A, 250V, 2P, 3-WIRE NEMA 6-30R
SPECIAL OUTLET: 50A, 250V, 2P, 3-WIRE NEMA 6-50R
SPECIAL OUTLET: 50A, 250V, 3P, 4-WIRE NEMA 14-50R
SPECIAL OUTLET: 50A, 250V, 3-PHASE, 4-WIRE NEMA 15-50R
JUNCTION BOX
JUNCTION BOX - WALL MOUNTED
JUNCTION BOX MOUNTED IN ACCESSIBLE CEILING SPACE. MOUNT FLUSH IN FLOOR WHEN
INDICATED IN A FLOOR BOX SYMBOL.
NON-FUSED DISCONNECT SWITCH
FUSED DISCONNECT SWITCH
MOTOR. NUMBER INDICATES HORSEPOWER RATING FOR 1HP AND LARGER
MOTOR. "F" INDICATES FRACTIONAL HORSEPOWER
TRACK CURRENT LIMITER. "#" DENOTES AMPS RATING.
POWER SUPPLY/DRIVER, CLASS 2 FOR LED
FLOOR BOX SPECIFICATIONS
SINGLE SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN.
WIREMOLD RFB2-OG/FPCTC WHEN SHOWN IN ON-GRADE
WIRE MOLD 6ATCP, 6ATP, OR 6ATCPAV AS REQUIRED WHEN SHOWN IN ABOVE GRADE.
TWO SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN.
WIREMOLD RFB2-OG/FPCTC WHEN SHOWN IN ON-GRADE
WIRE MOLD 6ATCP, 6ATP, OR 6ATCPAV AS REQUIRED WHEN SHOWN IN ABOVE GRADE.
SIGNAL
TELEPHONE OUTLET
DATA OUTLET
COMBINATION TELEPHONE/COMPUTER OUTLET
LIGHTING CONTROL SYMBOLS
SINGLE POLE SWITCH, 20A, 120/277V or CAT5e WIRED WALL SWITCH TO BE USED WITH
NON-DIMMING POWER/RELAY PACK
LOW VOLTAGE (0-10V) WALL MOUNTED SWITCH FOR MANUAL ON/OFF AND DIMMING
(STEPPED/CONTINUOUS) CONTROL OF LIGHTING. "a" INDICATES ZONE WHERE SHOWN ON
DRAWINGS.
OCCUPANCY SENSOR - WALL MOUNTED. "a" INDICATES CONTROLLED ZONE. SEE CONTROL
CONFIGURATIONS FOR MORE INFORMATION.
OCCUPANCY SENSOR w/ DIMMER - WALL MOUNTED. "a" INDICATES CONTROLLED ZONE.
SEE CONTROL CONFIGURATIONS FOR MORE INFORMATION.
1-WAY/2-WAY DIRECTIONAL CEILING MOUNTED, NON-NETWORKED/ INTERCONNECTED/
NETWORKED, SYSTEM-BASED OCCUPANCY SENSOR. QUANTITY OF ADJACENT LOWER CASE
LETTERS INDICATES QUANTITY OF RELAYS/DIMMING CIRCUITS REQUIRED - SEE CONTROL
CONFIGURATIONS BELOW FOR MORE INFORMATION. EXACT CONTROL FUNCTION IS DETERMINED
BY THE BALLAST/FIXTURE TYPE.
AUTOMATIC CONTINUOUS DIMMING DAYLIGHTING CONTROLLER USED TO DIM LIGHTS WHEN
SUFFICIENT NATURAL LIGHT IS PRESENT. NUMBER IN PARENTHESIS INDICATES THE AVERAGE
WORKPLANE "TARGET ILLUMINATION" SYMBOL VALUE. ADJACENT LOWER CASE LETTER(S)
INDICATES SWITCH LEG(S) CONTROLLED. ADJACENT "+, ++ AND *" INDICATES PORTION OF SWITCH
LEG CONTROLLED BY SENSOR WHERE "+" INDICATES PRIMARY SIDELIT DAYLIT ZONE, "++"
INDICATES SECONDARY SIDELIT DAYLIT ZONE, AND "*" INDICATES SKYLIT DAYLIT ZONE.
CONTROL CONFIGURATIONS
y "y" INDICATES THAT SWITCH LEG "y" TO BE CONFIGURED IN A "AUTO ON 100% / AUTO OFF" AND BE
CONTROLLED (CONTINUOUSLY DIMMED) BY THE ASSOCIATED CEILING SENSOR REMOTE SWITCH
ON THE WALL.
y,(y)"y,(y)" INDICATES THAT SWITCH LEG "y" TO BE CONFIGURED IN A "AUTO ON 50% / MANUAL ON 100%
/ AUTO OFF" AND BE CONTROLLED (CONTINUOUSLY DIMMED) BY THE ASSOCIATED DISTRIBUTED
LIGHTING CONTROLS.
(y)"(y)" INDICATES THAT SWITCH LEG "y" IS TO BE CONFIGURED IN A "MANUAL ON / AUTO OFF"
(VACANCY SENSOR) AND BE CONTROLLED BY THE ASSOCIATED DISTRIBUTED LIGHTING
CONTROLS.
J
J
J
30/1
30/3RF
5
F
y,(y)
(40)
y+,y++
APPLICABLE CODES
2022 CALIFORNIA BUILDING CODE (CBC)
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA MECHANICAL CODE (CMC)
2022 CALIFORNIA PLUMBING CODE (CPC)
2022 CALIFORNIA ENERGY CODE
2022 CALIFORNIA FIRE CODE
2022 NATIONAL FIRE ALARM AND SIGNALING CODE
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC)
ALLOWED SPECIFICATIONS DEVIATIONS
THE FOLLOWING ITEM(S) ARE ALLOWED DEVIATIONS FROM THE DRAWINGS AND
SPECIFICATIONS. THESE DEVIATIONS ARE AT THE DIRECTION OF THE OWNER.
NONE
SCOPE OF WORK
ELECTRICAL DESIGN FOR RETAIL AND BACKBAR RENOVATION.
DEFERRED APPROVAL
A.FIRE ALARM SYSTEM SHALL BE UNDER SEPARATE PERMIT. SEPARATE PLANS
SHALL BE SUBMITTED FOR APPROVAL BY A FIRE ALARM ENGINEER AND ALL
PERMITS, INSPECTIONS AND APPROVALS SHALL BE OBTAINED FROM THE FIRE
DEPARTMENT HAVING JURISDICTION.
B.VIA SEPARATE SUBMITTAL BY SIGN CONTRACTOR, OBTAIN APPROVALS AND
PERMITS FOR ALL SIGNS INCLUDING SIGN LIGHTING CERTIFICATE OF
COMPLIANCE.
C.VIA SEPARATE SUBMITTAL, OBTAIN APPROVALS AND PERMITS FOR ALL
ELECTRICAL SUBSYSTEMS WITH POWER SUPPLIES OF MORE THAN 50 VA AND/OR
250 VOLTS [E.G. SECURITY, TELCO/DATA, P.A, AUDIOVISUAL, HVAC CONTROLS,
ETC.]
DEMOLITION AND REWIRING SYMBOLS
"E"ADJACENT TO LIGHT FIXTURE OR OUTLET SYMBOL OR IN CONDUIT RUN
INDICATES EXISTING TO REMAIN. EXISTING CONDUCTORS TO REMAIN
UNLESS OTHERWISE NOTED ON DRAWINGS.
"EX"IN CONDUIT RUN INDICATES EXISTING CONDUIT RUN TO BE REWIRED.
PULL OUT EXISTING WIRES AND INSTALL NEW WIRES, QUANTITY AS
INDICATED BY HASH MARKS. REFER TO PLANS FOR WIRING
REQUIREMENTS. PROVIDE OTHER SYSTEM CONDUCTORS PER
SPECIFICATIONS.
"EA"ADJACENT TO LIGHT FIXTURE OR OUTLET SYMBOL OR IN CONDUIT RUN
INDICATES EXISTING TO BE ABANDONED. REMOVE DEVICE AND INSTALL
BLANK PLATE AND PULL WIRES FROM CONDUIT AS REQUIRED.
"R"ADJACENT TO LIGHT FIXTURE OR OUTLET SYMBOL OR IN CONDUIT RUN
INDICATES EXISTING TO BE REMOVED. EXISTING CONDUIT AND WIRE TO
BE COMPLETELY DISCONNECTED AND REMOVED BACK TO LAST
REMAINING OUTLET OR DEVICE.
"RR"ADJACENT TO ELECTRICAL OUTLET, EQUIPMENT, ETC. INDICATES
EXISTING TO BE REMOVED AND REPLACE WITH NEW.
"RL"ADJACENT TO ELECTRICAL OUTLET, EQUIPMENT, ETC. INDICATES
EXISTING TO BE REMOVED AND RELOCATED.
"R-X-E"
"E-X-R"
“X” INDICATES APPROXIMATE POINT OF INTERCEPTION OF EXISTING
CONDUIT RUN. CONDUIT TO BE REMOVED AT “R” SIDE OF “X”. REMOVE
ALL CONDUCTORS PRIOR TO CUTTING CONDUIT. EXACT LOCATION OF ALL
CONDUITS SHALL BE FIELD VERIFIED. EXTEND CONDUIT AND WIRES TO
MATCH EXISTING OR AS INDICATED ON PLANS. PROVIDE PULL BOX SIZE
PER CEC REQUIREMENT.
STAMP DATE: 04/13/2024
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
76085-018
<XX-XX-XXXX>
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
Revision Schedule
Rev Date By Description
E002
ELECTRICAL
SPECIFICATIONS
PART I - GENERAL
A. CONDITIONS
1.Furnish and install a completely wired and operational electrical system as
shown on the drawings and specified herein, including but not limited to,
these major items.
1.1.Lighting fixtures as indicated and specified on the plans.
1.2.Electrical panels, service, conduit, wiring, etc., for all outlets and
equipment.
1.3.Telephone outlets and conduit as indicated.
B. RELATED WORKS
1.The Electrical Contractor shall provide conduit, trench, and backfill for
electrical service entrance from the main service to utility point of electrical
service. Electrical Contractor shall coordinate the installation of the
electrical service entrance with serving utility company.
2.The Electrical Contractor shall provide conduit, trench, and backfill for
primary phone and CATV service from the telephone terminal board or
cabinet to the phone company and CATV company point of service.
C. CODES, REGULATIONS, AND STANDARDS
1.The installation shall comply with applicable local and state codes and
ordinances, with the regulations of the currently accepted edition of the
National Electric Code and with the requirements of the power, telephone,
and CATV companies furnishing services to this installation.
2.The following industry standards, specifications, and codes are minimum
requirements:
2.1.The National Electrical Code (NEC), including local amendments.
2.2.Underwriter Laboratories (UL) incorporated standards.
2.3.American National Standards Institute (ANSI).
D. INSPECTION OF SITE
1.Prior to submitting a bid for electrical work, the contractor shall visit the site
of the proposed construction and shall thoroughly acquaint himself with
existing utilities, and working conditions to be encountered, etc. Allowance
will not be made for noncompliance with this condition after bidding.
2.Electrical installation shall meet the existing conditions.
E. STORAGE AND HANDLING OF MATERIALS
1.Deliver materials and equipment to the project in the manufacturer's original,
unopened, labeled containers. Protect against moisture, tampering, or
damage from improper handling or storage. Contractor shall protect and be
responsible for any damage to work or materials until final acceptance by
the owner, and shall make good without cost to the owner, any damage or
loss that may occur during this period.
2.Arrange for timely delivery of materials and equipment to the job site in
order to minimize the length of time between delivery and installation.
3.Cover and protect any material which may be affected by the weather while
in transit or stored at the project site. Any material found defective or not
installed in accordance with the contract documents may be rejected by the
engineer.
F. CLEANUP
1.Keep the premises free from accumulation of waste materials, or rubbish
caused by employees or work under this division of the specifications. At
the completion of the work remove all surplus materials, tools, etc., and
leave the premises broom-clean.
H. DRAWINGS
1.The drawings indicate the general arrangement and locations of the
electrical work data presented on these drawings are as accurate as
planning can determine, but field verification of all dimensions, locations,
levels, etc., to suit field conditions is required. Review all architectural,
structural, and mechanical drawings and adjust all work to meet the
requirements of conditions shown. The architectural drawings shall take
precedence over all other drawings. Discrepancies between different plans,
or between drawings and specifications, or regulations and codes governing
the installation shall be brought to the attention of the engineer in writing
before the date of bid opening. If discrepancies are not reported, the
Contractor shall bid the greater quantity or better quality, and appropriate
adjustments will be made after contract award. Contractor shall be
responsible to field measure and confirm mounting heights and location of
electrical equipment with respect to counters, radiation, etc. Do not scale
distances off the electrical drawings, use actual building dimensions.
I. EXCAVATION, CUTTING, AND FITTING
1.Perform the excavation, cutting, fitting, repairing, and finishing of the work
necessary for the installation of the equipment of this section. However, no
cutting of the work of other trades or of any structural members shall be
done without the consent of the architect.
J. COOPERATION WITH OTHER CONTRACTORS
1.Cooperate with the other trades so that the installation of the electrical
outlets and equipment will be properly coordinated. Conduit, lighting
fixtures, and other equipment locations shall be checked with other trades to
avoid conflict with the piping, ductwork, steel, beams, or other obstructions.
Carefully check the locations of the outlet boxes and determine that they
have not been disturbed during the installation of materials of other trades.
2.Coordinate the location of the trenches and conduits for electrical and
telephone utility services with the general contractor.
3.Coordinate HVAC equipment connection requirements with HVAC
contractor.
PART II - PRODUCTS AND EXECUTION
A. MATERIALS
1.All materials shall be new and of quality as specified on the plans or
specifications and must carry the Underwriter's Laboratories approval
covering the purpose for which they are used, in addition to meeting all
requirements of the current applicable codes and regulations.
B. CONDUIT
1.All wiring shall be installed in listed metallic conduit except as permitted
below. RGS, with a 20 mil PVC coating will be used when in contact with
earth. IMC may be used in indoor locations not in contact with the earth.
EMT may be used in indoor locations not in contact with earth, not in
concrete slabs or walls and not subject to damage. PVC may be used in or
below concrete and direct buried in earth. Flexible steel conduit shall be
used for indoor final connections to equipment in lengths not to exceed 72".
Liquid-tight flexible steel conduit shall be for outdoor final connections to
equipment not to exceed 36".
2.Cover metallic conduit in contact with earth with polyethylene taped spiral
wrapped, 1/2 lapped to provide 20 mil. thickness. Tape shall be Scotch no.
50 tape. Conduit and ducts not under buildings and feeder ducts shall be
installed per N.E.C. 300-5. make joints with compound to be watertight.
3.Fittings and conduit bodies shall be steel. No diecast fittings.
4.Conduit sizes shall be as required by code and as indicated or specified.
5.All empty conduit systems shall have a nylon pull string to facilitate
installation of future wire.
6.Schedule 40 PVC conduit shall be permitted underground with proper
fittings, all UL Approved and cemented joints. Penetrations through floor
slabs and bends greater than 22° shall be wrapped rigid galvanized steel
elbows.
7.Conduits and outlets shall be concealed with the building structure, except
that certain motor and lighting feeder conduits may be run exposed in
certain areas as indicated on the drawings. Conduit shown to be installed in
cabinets, counters, and casework shall be run as directed by the architect.
8.All conduit systems shall have a Code sized copper ground conductor
increase conduit size as required.
9.Conduit penetration through roof shall have roof flashing with caulk type
counter flashing sleeve. Installation shall be watertight.
10.Conduits shall be routed surface on the structure, parallel and perpendicular
to the structure.
C. OUTLET, PULL, AND JUNCTION BOXES
1.Each switch, light. receptacle or other outlet shall be provided with a Code
gauge, galvanized steel outlet box. Junction and pull boxes shall be Code
gauge, galvanized steel. Outlet boxes shall be of the one piece, knockout
type, in general 4" square with plaster ring. Plaster rings shall be set to
provide not more than 1/8" from wall surface to ring. In no case shall
plaster ring project beyond surface of wall. Single gang rings similar to
Steel City 52050 shall be used for 4" boxes in unfinished brick number 180
boxes may be used for unfinished masonry flush wall outlets. Center all
outlet boxes in block course.
2.Boxes installed in poured cement floors shall be flush type cast iron or steel
with watertight gasketed covers. Where boxes are installed in floors with
tile or carpet floor covering, covers shall be of the recessed type to
accommodate the floor covering.
3.Boxes installed for the alarm, computer, and security system shall be
provided with appropriate cover plates.
4.Boxes for telephone, computer, TV, fire alarm, security, and similar systems
shall be minimum 4" square and 2-1/8" deep.
D. SWITCHBOARDS, DISTRIBUTION BOARDS, MOTOR CONTROL
CENTERS
1.See Single Line Diagram General Notes on drawings for more information.
E. PANEL BOARDS
1.See drawings for panel board schedules and specifications.
F. WIRE
1.Conductor sizes shown on the drawings are based on copper wire. Unless
otherwise specified, all wire shall be Type XHHW for feeders or branch
circuits larger than 4 AWG, Type THHN/THWN insulation for feeders and
branch circuits 4 AWG and smaller. All branch circuit wiring shall be
copper. The wire shall be 12 AWG unless otherwise indicated. Circuit shall
be labeled in each junction box.
2.Metal Clad Cable "Type MC" cable may only be utilized for interior branch
circuitry supplying lighting fixtures, not to exceed 6-ft. in length from junction
box to the fixture served. "Daisy Chaining" of light fixtures is not allowed.
3.When use is permitted in the Allowed Specification Deviations, Metal Clad
"Type MC" cable may be installed per NEC Article 330. Where multiple
cables are routed adjacent to each other (bundled), a minimum separation
of one (1) cable diameter (largest) shall be required.
4.The wires shall be marked with color to simplify circuit identification. Unless
otherwise required by local ordinances:
208/120 Volts
Phase A = Black
Phase B = Red
Phase C = Blue
Neutral = White
Ground = Green
480/277 Volts
Phase A = Brown
Phase B = Orange
Phase C = Yellow
Neutral = Gray
Ground = Green
5.No wire shall be installed in the conduit system until the conduit system is
complete. Use Mineralac No. 100 or equivalent as a lubricant to facilitate
the installation of the conductors in the conduit system.
6.Splices in exterior pull boxes and manholes shall be weatherproof using
"Scotchcast" splice kit or approved equal. Seal ends of conduits and ducts
with "Ductseal" or approved equal.
7.Provide solid conductor for 12 AWG and smaller.
8.Provide 10 AWG conductors for 20 ampere, 120V branch circuits longer
than 75-feet and 8 AWG conductors for 20 ampere, 120V branch circuits
longer than 120-feet. Provide 10 AWG conductors for 20 ampere, 277V
branch circuits longer than 200-feet.
G. WIRING DEVICES
1.Wall switches shall be Specification Grade AC silent type switches, 20A,
120/277 volt.
2.Receptacles shall be Specification Grade, duplex type, NEMA 5-20R, 20
ampere, 120 volt grounded type. Special application receptacles shall be
indicated on plans. Mount with the ground down.
3.Device plates shall be equal to sierra smooth-line plastic wall plates. Color
shall be white, unless otherwise noted.
4.All receptacles identified as weatherproof on the drawings shall be
weather-resistant, tamper-resistant, GFCI type and equipped with enclosure
that is weatherproof (WP) whether or not the attachment plug cap is
inserted (while "IN-USE"). An outlet box hood shall be listed and shall be
identified as "Extra Duty".
5.Except as otherwise noted, all wiring device plates on the project shall be
labeled with panel and circuit number(s) utilizing a Brother P-touch labeling
system with 1/2" tape (yellow on black) or equal HellermannTyton or
Panduit. Locate label on the concealed side of the wiring device plate.
Handwritten labels are unacceptable.
H. LIGHTING FIXTURES
1.Provide all lighting fixtures, wired and connected. the drawings indicate the
fixtures for each location. Provide lamps for all fixtures. The lamps shall be
by the same manufacturer. Verify ceiling construction before ordering
recessed units. Provide plaster frames and hangers as required. Ceiling
construction, architectural accessories, voltage, and ballasts to meet the
existing condition.
J. SYSTEM GROUNDING
1.Grounding shall comply with requirements of Article 250. All exposed
non-current carrying metallic parts of electrical equipment, metallic raceway
systems, metallic cable armor, grounding conductor of nonmetallic sheathed
cables, grounding conductor in nonmetallic raceways, and grounded
conductors of the wiring system shall be grounded.
2.Grounding conductor (neutral) of the wiring system shall be connected to
the system grounding conductor at a single place in each system by
removable bonding jumpers, sized according to the applicable provisions of
the National Electrical Code. The grounded conductor (neutral) to the
grounding conductor connection shall be located in the enclosure for the
system's overcurrent protection or where otherwise indicated on the plans
or specifications.
3.A ground bus separate from the neutral bus shall be provided in all
switchboards and panelboards. Ground bus shall be retorqued (checked)
prior to energizing equipment per manufacturer's recommendations.
4.Ground buses and neutral buses in all distribution panels, switchboards,
panelboards, and those provided in any equipment shall be isolated except
where required to be connected as specified above for the service entrance
and in transformer terminal compartments.
5.When indicated on the drawings, equipment grounding conductors shall be
extended from the ground bus in the distribution equipment to the
receptacle, fixture or device lugs where they are provided. Where lugs are
not provided, equipment grounding conductors shall be connected to
equipment enclosures. The connections shall be arranged such that
removal of the receptacle, equipment ground conductors, or ground
jumpers from ground busing shall not affect the ground system.
6.Raceways may not be used as a grounding conductor for power and lighting
circuits. All conduit shall have separate Code sized green ground wire
installed in the conduit to insure a continuos grounding path.
7.In inaccessible locations, make connections by exothermic weld process.
8.In accessible locations, connections shall be made with bolted through,
approved solderless bronze grounding devices.
9.Bond together metal siding not attached to grounded structure bond to
ground.
K. TELEPHONE SYSTEM
1.Telephone wall outlets shall consist of standard boxes mounted 18" above
the floor unless otherwise indicated. Connect outlets to telephone terminal
with separate 3/4" conduit unless otherwise shown on drawings. Provide a
terminal mounting board for the incoming service cable.
L. LIGHTING CONTROL
1.Furnish and install time switches, photocells, contactors and full lighting
control systems as required for lighting controls indicated on the drawings.
2.Time switches shall be equal to Paragon, General Electric, Tork, or
Intermatic and shall have size and number of poles as required.
3.Photocells shall be equal to Tork or Intermatic with voltage as indicated.
N. GUARANTEE
1.Guarantee all material furnished and all workmanship performed for a
period of one year from date of final acceptance of work. Any defects
developing within this period, traceable to material furnished as a part of this
section or workmanship performed hereunder, shall be made good at no
expense to the owner.
O. SHOP DRAWINGS AND APPROVALS
2.The items specified herein and on drawings are used as a standard of
quality. any materials of equal quality and aesthetic value will be given
consideration as a substitute for the materials specified. No approval will be
given to a specific catalog number, model, or type of equipment, prior to
bidding. After bidding, the decision of the Architect and/or Engineer
determining equal materials will be final.
3.The contractor shall submit shop drawings on the following items:
3.1.Lighting fixture cuts and performance data.
3.2.Outline drawings and data sheets of each panelboard and switchboard.
3.3.Outline drawings of all switchgear.
4.Submit items at one time in a neat and orderly manner within 15 days of
award of contract. Partial submittals will not be acceptable.
P. RECORD AND AS-BUILT DRAWINGS
1.The Electrical Contractor shall maintain a set of drawings at the job site for
the exclusive purpose of maintaining a record of all work installed and to
show any deviations from the work indicated on the drawings.
2.At the completion of the project, one set of reproducible drawings, showing
all As-Built conditions, shall be delivered to the Owner for acceptance prior
to final payment.
R. EQUIPMENT CONNECTIONS
1.Provide flexible connections to all HVAC equipment, water heater, etc any
equipment over 20 lb and/or mounted above finished floor.
2.Coordinate electrical requirements for all plumbing and mechanical
equipment with final Contractor selection. The Contractor shall size
disconnects based upon circuit breaker ratings and provide fusing as
required per equipment manufacturer recommendations and UL Listing
requirements.
T. FIRE SYSTEM
1.Contractor shall engage the services for a state licensed fire alarm
manufacturer/installer to prepare all design drawings and calculations
required for system approval by the authority having jurisdiction. Submit all
plans and provide all permits required for a complete and operable
approved life safety system.
2.Fire alarm device wiring shall be minimum #14 AWG copper or per system
manufacturer requirements. Provide minimum 3/4" separate raceway
system or as required for life safety system wiring configuration.
3.Upon completion of the installation of life safety system wiring and devices,
a performance test of the entire life safety shall be performed to the
satisfaction of the authority having jurisdiction.
U. LOW VOLTAGE SYSTEMS
1.Music, television, video mounting systems are not shown on these drawings
and are provided by Contractor through architects schedules/details.
Contractor to coordinate all routing and final connections as approved by
Starbucks Manager as applicable specifically to this store.
V. IDENTIFICATION OR EQUIPMENT LABELING
1.Nameplates shall be provided for switchgear, switchboards, distribution
boards, distributions panels, panel boards, motor control centers,
transformers, transfer switches, contactors, starters, disconnect switches,
enclosed circuit breakers/switches, Inverters, UPS's, PDU's, RDC's, SPD's,
lighting control panels, dimming panels, door releasing system panels, fire
alarm/central monitoring terminal cabinets/power supplies/control panels,
and all low voltage system terminal and control cabinets.
1.1.Nameplate inscriptions shall be identical to the equipment designations
indicated in plans and specifications. Nameplates shall be engraved
with the device designation/identification on the top line, source
identification for the device on the 2nd line per NEC, Art 408.4 and load
designation for the device on the bottom line. Where load designation
consists of a branch circuit, omit bottom line. Where device
designation is not intended on plan/specfications. Contractor shall
submit a written clarification request to the Engineer.
1.2.All circuit breakers/fuses in switchgear, switchboards, distribution
boards, distribution panels, UPS output circuit breakers, PDU sub-feed
circuit breakers and motor control centers shall have individual
nameplates located immediately adjacent to the respective device.
Nameplate inscription shall identify the downstream equipment or
device served by the circuit breaker or fuse.
2.Identification nameplates, unless otherwise noted (UON), shall be
laminated/extruded modified acrylic or melamine plastic labels that is 3/32"
thick, UV-stabilized, matte finish, suitable for use in 180°F ambient, with
beveled edges and engraved white letters 3/8" high, minimum, on 1-1/2"
high black background for single line of text. Where two lines of text are
required, provide minimum 2" high nameplate. Where three lines of text are
required, provide 2.5" high nameplate. Provide white letters on red
background for all NEC, Article 517 essential power systems, Article 700
Emergency Systems, Article 701 Legally Required Standby Systems and
Article 708 COPS.
3.Identification nameplates for new switchgear, switchboards, distribution
boards, distribution panels, panel boards and motor control centers shall be
attached with switchgear manufacturer-provided screws via switchgear
manufacturer factory pre-drilled holes. A factory option to rivet identification
nameplates to the equipment is only acceptable if screw-fastened
nameplates are not an available option from the switchgear manufacturer.
Field drilling or other mechanical attachment methods that change/void the
NEMA or NTRL rating of the enclosure are strictly forbidden.
4.Identification nameplates for transformers, transfer switches, disconnect
switches, enclosed circuit breakers/switches, inverters, UPSs, PDUs, RDCs,
SPDs, lighting control panels, dimming panels, door-releasing system
panels, terminal cabinets and all circuit breakers/fuses in switchgear,
switchboards, distribution boards, distribution panels, UPS output circuit
breakers, PDUs, PDU sub-feed circuit breakers, and motor control centers
shall be attached to the equipment by self-adhesive backing integral to the
nameplates. When equipment is located outdoors, provide nameplates
without self-adhesive backing and attach to equipment using weather-rated,
UV-resistant epoxy. In all cases, clean surfaces before applying
identification nameplates parallel to equipment lines.
5.Warning Placards, as required by General Single Line Diagram Notes for
multiple power sources, or instruction placards, as required for all kirk-key
interlock schemes, all UPS bypass procedures or as required elsewhere in
the plans/specifications shall be engraved 1/2" high with white lettering on
red background using the same material specified for identification
nameplates with a self-adhesive backing. Warning/instruction placards shall
be attached to the face of the equipment directly related to the placards.
STAMP DATE: 04/13/2024
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
ADJACENT
TENANT
(NIC)
L 20662
L 21772
L 21772
L 20661
L 21776
L 19409
L 21779
L 21774
L 20748
L 21774
L 20748
L 21774
L 21783
L 21772
BACKBAR
RETAIL
SEATING
AREA
WORKROOM
PARTNER /
MANAGER
AREA
UNISEX
PARTNER
RESTROOM
UNISEX
CUSTOMER
RESTROOM
(N) 2X4 ACT AT
10' - 0" AFF
(N) GYP BD CEILING
AT 10' - 11" AFF
BACKBAR
(N) GYP BD CEILING
AT 9' - 6" AFF
(N) SOFFIT AT 7'-6" AFF
(SG)
(N) SOFFIT AT 11'-10" AFF
(N) HEADER
AT 9' - 6" AFF
(N) 2X4 ACT ABOVE RO
& WH AT 12'-6" AFF
(N) GYP BD CEILING
AT 9' - 0" AFF
(N) GYP BD CEILING
AT 9' - 0" AFF
(N) GYP BD CEILING
AT 9' - 0" AFF
(N) GYP BD CEILING
AT 10' - 11" AFF
L 21774
(3)
(32)
(6)
L 21772 (14)
L 21772
(4)
(6)
(2)
(2)
(2)
(2)
(N) HEADER
AT 7' - 6" AFF
L 22216
L 22216
L 22220
L 22220
L 22216
(7)
L 21776
UPLIGHT:C
DOWNLIGHT:C
UPLIGHT:C
DOWNLIGHT:B
+
(N) ZINTRA
ACOUSTICAL
BAFFLES AT
11' - 2" AFF
L 19411
L 21779 (3)
L 19409
L 21779
L 19409
L 21779 (2)
L 19409
L 21779
L 19409
L 21779
TYP.
22w/22EB 22w 22w
22w/22EB 22w
22w 22w
22w
22p22p22p
22p/22EB 22p 22p
22u 22u
22u
22v/22EB
22v
24b
24b24b
24b/24EB
24b24b
24b
24b 24b 24b 24b
24b
24b
24b/24EB
24c 24b 24b 24b 24b 24b
24b24b24b24b24b24b24b24b24b24b24b24b24b24b24b24b24b/24EB
24b 24b/24EB 24b
24r
24b24b24b24b24b24b24b24b24b24b24b24b/24EB
24r
24r
24r
24r
24r
24r
22n
22n
22n
24t
24t
24t
24t/24EB24t/2EB
24t
24r
24t 24t
24r
24r
24r
24NL/24EB
22NL/22EB
24b
24c
22u
1
24b
5
6
4
4
7
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
76085-018
<XX-XX-XXXX>
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
Revision Schedule
Rev Date By Description
E200
LIGHTING PLAN
SCALE:1/4" = 1'-0"1 LIGHTING PLAN
REFERENCE NOTES
NEW LUTRON SWITCHBANK, REFER TO LUTRON ONE-LINE AND LOOP LAYOUT.
LIGHT SWITCHES ARE SPECIFIED ON LUTRON ONE-LINE.
NEW EMERGENCY/EXIT FIXTURE, GC TO PERFORM TEST TO ENSURE
EMERGENCY BATTERY UNIT WILL PROVIDE BACKUP POWER FOR MINIMUM 90
MINUTES.
ROUTE CIRCUIT VIA LUTRON VIVE SYSTEM TIME CLOCK.
DASHED LINE INDICATES LED LIGHT TAPE HOUSED WITHIN SOFFIT LIGHT
COVE.
DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE UPPER CBE
CABINETRY.
DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE FRONTLINE
COUNTERTOP BELOW.
DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE PARTNER
REST UPPER CABINETRY.
1
2
3
4
5
6
7
A.PROVIDE A DISCONNECTING MEANS FOR EACH MULTI-WIRE LIGHTING
BRANCH CIRCUIT IN ACCORDANCE WITH NEC 410.130(G)(1)THRU(3).
DISCONNECTING MEANS SHALL BE LOCATED AT POINT WHERE CIRCUIT
ORIGINATES AND SHALL SIMULTANEOUSLY DISCONNECT ALL
UNGROUNDED CONDUCTORS.
B.REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT
LOCATION AND ELEVATION OF ALL LIGHTING FIXTURES.
C.THE FIXTURE SCHEDULE INDICATES GENERAL DESCRIPTION OF LIGHTING
FIXTURES AND MANUFACTURERS CATALOG NUMBERS. IT SHALL BE THE
CONTRACTORS RESPOSIBILITY TO VERIFY EXACT CEILING CONSTRUCTION
WITH ARCHITECTURAL REFLECTED CEILING PLAN AND PROVIDE LIGHTING
FIXTURES WITH ALL NECESSARY TRIMS, AND MOUNTING HARDWARE.
D.COORDINATE EXACT LIGHTING FIXTURE LOCATIONS WITH ELECTRICAL,
MECHANICAL, PLUMBING EQUIPMENT, INCLUDING CONDUIT, PIPING,
DUCTING ,ETC PRIOR TO ROUGH-IN.
E.ALL RECESSED FIXTURES SHALL BE PROVIDED WITH ALL REQUIRED
STRUCTURAL SUPPORTS AS REQUIRED BY THE CURRENTLY ADOPTED
ISSUE OF THE BUILDING CODE, AS WELL AS ANY LOCAL CODES.
F.ALL DIMMING BRANCH CIRCUITS SHALL BE PROVIDED WITH A DEDICATED
NEUTRAL CONDUCTOR FOR EACH ZONE/CHANNEL.
G.ALL EMERGENCY BATTERY PACK FIXTURES SHALL BE PROVIDED WITH A
CONSTANT HOT CONNECTION TO THE CHARGING LEAD OF THE LOCAL
AREA CIRCUIT.
H.REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXIT SIGN
CHEVRONS AND NUMBER OF FACES PER EXIT SIGN. ANY DISCREPANCIES
BETWEEN EXIT SIGNS SHOWN ON THE ELECTRICAL AND ARCHITECTURAL
PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR
TO ORDERING EXIT SIGNS. A JUNCTION BOX MUST BE PROVIDED WITH ALL
EXIT LIGHTS CONNECTED TO MORE THAN ONE SET OF CONDUCTORS
UNLESS THE EXIT LIGHT FIXTURE IS FURNISHED WITH AN APPROVED
OUTLET BOX FOR THROUGH WIRING.
I.ALL LOW VOLTAGE LIGHTING SYSTEMS SHALL COMPLY WITH NEC 411 AND
SHALL BE LISTED PER 411.3 OR LOCAL CODES HAVING JURISDICTION.
J.ALL ELECTRICAL EQUIPMENT LOCATED OUTSIDE SHALL BE
WEATHERPROOF.
K.ALL LOW VOLTAGE WIRING NOT RUN IN CONDUIT SHALL BE PLENUM RATED.
L.MOUNT ALL SWITCHES, CONTROLS, RECEPTACLES BETWEEN 15"-48" AFF.
H.ADDITIONAL RELAY ZONES MAY BE REQUIRED FOR THE ADDITION OF
PRIMARY DAYLIT, SECONDARY DAYLIT, AND PRIMARY SKYLIT UTILIZING THE
SAME CONTROL CHANNEL. (I.E. EVEN THOUGH A SINGLE LETTER "a" IS
INDICATED AT THE PRIMARY SENSOR), ADDITIONAL RELAYS WOULD BE
REQUIRED FOR THE:
"a+"PRIMARY SIDELIT DAYLIT ZONE
"a++"SECONDARY SIDELIT DAYLIT ZONE, AND
"a*"SKYLIT DAYLIT ZONE
WHERE MORE THAN ONE CIRCUIT /THREE SWITCH LEGS/THREE RELAY
ZONES ARE REQUIRED PROVIDE ADDITIONAL FULL FEATURE CONTROL
UNITS AS REQUIRED.
I.LUMINAIRES INDICATED AS EMERGENCY SHALL BE IDENTIFIED / PROVIDED
AS FOLLOWS:
-FIXTURE CONNECTED TO CIRCUIT "3", CONTROL SWITCH
"a" - WITH THE BATTERY CHARGING LEAD CONNECTED
TO A CONSTANT HOT CIRCUIT "3".
-FIXTURE CONNECTED TO A CONSTANT HOT CIRCUIT "#3".
BATTERY CHARGING LEAD CONNECTED TO A CONSTANT
HOT CIRCUIT "3".
-ROUTED THROUGH A U.L. LISTED TRANSFER RELAY (LC &
D # GR - 2001E/S) FOR SWITCHED CONTROL OR A U.L.
LISTED TRANSFER SWITCH (BODINE #GTD SERIES
DEVICE) FOR DIMMING CONTROLS . CONNECTED TO A
CONSTANT HOT EMERGENCY CIRCUIT "3".
-FIXTURE CONNECTED TO A CONSTANT HOT EMERGENCY
CIRCUIT "#3".
1.INTEGRAL BATTERY PACK (EB):
3a/3EB
3NL/3EB
3a/3EM
3NL/3EM
2.REMOTE BACK-UP SOURCE (EM)
LIGHTING PLAN GENERAL NOTES
(E)
STAMP DATE: 04/13/2024
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
76085-018
<XX-XX-XXXX>
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
Revision Schedule
Rev Date By Description
E210
LUTRON
ONE-LINE DIAGRAM
FOR REFERENCE
ONLY
STAMP DATE: 04/13/2024
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
76085-018
<XX-XX-XXXX>
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
Revision Schedule
Rev Date By Description
E220
LUTRON
LOOP LAYOUT
FOR REFERENCE
ONLY
STAMP DATE: 04/13/2024
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
ADJACENT
TENANT
(NIC)
BACKBAR
RETAIL
SEATING
AREA
WORKROOM
PARTNER /
MANAGER
AREA
UNISEX
PARTNER
RESTROOM
UNISEX
CUSTOMER
RESTROOM
Y 19581
1
E310
SA-20
T
A-
1
6
T
A-
1
8
RA-13
13620A-19
UA-15,17
23
1
8
2
A-
1
2
,
1
4
23
4
2
3
A-
8
+72"
A1
B-
3
9
A1 B-43
23454B-29
10267B-31
+84"
+84"
+84"
A
B
(E)
(E)
+84"+84"
2
1
E330
2
E330
QA-47
A-47
1
FOR AIR CURTAIN
B-38
A-50
B-25
B-25
WA-25,27,29
23355A-49
100AS/3P
+76"
3
+54"
A-51
A-51
FOR R.O.
SYSTEM
+47"
A-23
A
EXISTING ITEMS TO PRESERVE AND RELOCATE
A BLENDERS (2)
B ESPRESSO MACHINES (2)
C SAFE
Q WATER FILLING STATION
K WARMING OVEN (2)
T 2-DR REACH IN FRIDGE (2)
S 2-DR REACH IN FREEZER
D WARMING U/C FRIDGE (2)
P MANAGER'S STATION EQUIPMENT
R 1-DR REACH IN FREEZER
E 1-DR U/C FRIDGE (5)
M DRIVE-THRU POS EQUIPMENT
L POS EQUIPMENT, PRINTER, & PHONE
H NITRO TAP / NITRO GENERATOR
G CUP LABELER (4)
F GRINDER
I NOT USED
J CUP CADDY (2)
N PASTRY CART
O AV DIGITAL PRODUCTION MANAGER
V THAW RACK
U SANITIZER
W R.O. SYSTEM & WATER HEATER
X TRASH BIN
Y METRO RACKS (10)
Z ICE BIN
A1 HAND DRYER (2)
B1 DATA RACK
C1 LOCKERS (2)
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
76085-018
<XX-XX-XXXX>
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
SA
N
T
A
A
N
A
,
C
A
,
92
7
0
5
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
7
/
0
2
/
2
0
2
4
Revision Schedule
Rev Date By Description
E300
POWER PLAN
SCALE:1/4" = 1'-0"1 POWER PLAN
A.ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND
OFFSET 24" MINIMUM.
B.ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED
FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL
OR GREATER THAN THE FIRE RATING OF THE WALL.
C.HEIGHT OF ALL RECEPTACLES AT COUNTER SHELVES, ETC., SHALL BE
VERIFIED WITH OWNER PRIOR TO ROUGH-IN.
D.ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C.
RUN CODE SIZE INSULATED EQUIPMENT GROUND CONDUCTOR.
E.EACH AND EVERY 125VAC THROUGH 250VAC RECEPTACLE SUPPLIED BY A
SINGLE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND,
50 AMPERES OR LESS, AND ALL THREE-PHASE RECEPTACLES RATED 150
VOLTS OR LESS TO GROUND, 100 AMPERES OR LESS INSTALLED IN
KITCHEN, FOOD PREPARATION, BAR AREAS AND RESTROOMS SHALL HAVE
A GROUND FAULT CIRCUIT-INTERRUPTER PROTECTED RECEPTACLE OR
RECEPTACLE(S) PROTECTED BY GFCI CIRCUIT BREAKER. ANY RECEPTACLE
INSTALLED WITHIN 6 FEET OF A SINK MUST BE G.F.C.I. TYPE.
F.FOR ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30
AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES TO BE
LOCATED:
A. NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE
RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, AND
B. NO LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE
RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, TO THE LEVEL OF
THE FINISHED FLOOR OR WORKING PLATFORM.
G. CIRCUIT NUMBERS ARE BASED ON CURRENT PANEL SCHEDULES. WHERE
CIRCUIT IS TO BE REPLACED OR RELOCATED, CONTRACTOR IS TO VERIFY
CORRECT NUMBERING AND UPDATE THE PANEL SCHEDULE.
H. ELECTRIC OUTLETS, SWITCHES, THERMOSTATS, FIRE ALARMS AND SIMILAR
DEVICES SHALL BE LOCATED A MINIMUM OF 15" ABOVE THE FINISHED
FLOOR, MEASURED TO THE BOTTOM OF THE BOX, AND A MAXIMUM OF 48"
ABOVE THE FINISHED FLOOR, MEASURED TO THE TOP OF THE BOX.
J. ALL PANEL CIRCUIT NUMBERS ARE FOR REFERENCE ONLY, AND ARE BASED
ON EXISTING PANEL SCHEDULES FOUND AT SITE. CONTRACTOR TO
PROVIDE AN UPDATED PANEL SCHEDULE TO OWNER UPON COMPLETION.
K.ELECTRIC WATER HEATERS MUST BE PROVIDED WITH A DISCONNECT. THE
CIRCUIT BREAKER MAY SERVE AS THIS DISCONNECT WHEN IT IS WITHIN
SIGHT OF THE WATER HEATER OR WHEN PROVIDED WITH A LOCK-ON /
LOCK OFF FEATURE.
POWER PLAN GENERAL NOTES
REFERENCE NOTES
PROVIDE 2#8 & 1#10 EGC IN 3/4"C
INDICATES ADA "PUSH TO OPEN" PUSH PAD FOR ADA COMPLIANT AUTOMATIC
DOOR OPENER. REFER TO MANUFACTURER'S WIRING DIAGRAM FOR
TERMINAL CONNECTION. REFER TO ARCHITECTURAL PLANS FOR
MANUFACTURER AND MODEL NO.
PROVIDE 3#4 & 1#8 EGC IN 1-1/4"C
TAMPER-RESISTANT RECEPTACLE OUTLET WITH USB CHARGING PORT
PROVIDED BY BANQUETTE SEATING SUPPLIER. COLOR TO MATCH
BANQUETTE SEATING. ELECTRICAL CONTRACTOR TO PROVIDE CONNECTION
TO JUNCTION BOX.
JUNCTION BOX FOR BANQUETTE SEATING SUPPLIED RECEPTACLE OUTLETS.
1
2
3
4
5
5
4 (TYP)
A 07/02/24 D/T AIR CURTAIN/ HAND SINK
STAMP DATE: 07/02/2024
Email: info@peccusa.com
Phone: 909.610.5364
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
2301 N Tustin Ave
#A8/22/2024
(2)
F
B-
2
0
23
3
8
1
A-
3
1
,
3
3
K
B-
1
,
3
K
B-
5
,
7
D
B-
1
8
D
B-
1
8
G
B-
9
23
4
4
3
A-
3
5
,
3
7
,
3
9
10
2
6
7
B-
2
1
23
4
4
4
A-
4
2
,
4
4
E
B-
1
2
E
B-
6
B
B-
2
,
4
B
B-
1
4
,
1
6
222
C
A-
4
1
L
B-
1
9
L
B-
1
7
16238B-13,15
B-11
10
2
6
7
B-
1
0
O
B-
1
0
22970A-46
1
E320
1
E320
2
2
4
1
222
2
33
4 4
5
A-36
2
22
6
4
2
22
6
4
2
G
B-
9
224
6
A
A
EXISTING ITEMS TO PRESERVE AND RELOCATE
A BLENDERS (2)
B ESPRESSO MACHINES (2)
C SAFE
Q WATER FILLING STATION
K WARMING OVEN (2)
T 2-DR REACH IN FRIDGE (2)
S 2-DR REACH IN FREEZER
D WARMING U/C FRIDGE (2)
P MANAGER'S STATION EQUIPMENT
R 1-DR REACH IN FREEZER
E 1-DR U/C FRIDGE (5)
M DRIVE-THRU POS EQUIPMENT
L POS EQUIPMENT, PRINTER, & PHONE
H NITRO TAP / NITRO GENERATOR
G CUP LABELER (4)
F GRINDER
V THAW RACK
U SANITIZER
W R.O. SYSTEM & WATER HEATER
X TRASH BIN
I NOT USED
J CUP CADDY (2)
N PASTRY CART
O AV DIGITAL PRODUCTION MANAGER Y METRO RACKS (10)
Z ICE BIN
A1 HAND DRYER
B1 DATA RACK
C1 LOCKERS (2)
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
76085-018
<XX-XX-XXXX>
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
SA
N
T
A
A
N
A
,
C
A
,
92
7
0
5
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
7
/
0
2
/
2
0
2
4
Revision Schedule
Rev Date By Description
E310
ENLARGED
ENGINE PLAN
SCALE:1/2" = 1'-0"1 ENLARGED FF&E POWER PLAN
A.ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND
OFFSET 24" MINIMUM.
B.ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED
FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL
OR GREATER THAN THE FIRE RATING OF THE WALL.
C.HEIGHT OF ALL RECEPTACLES AT COUNTER SHELVES, ETC., SHALL BE
VERIFIED WITH OWNER PRIOR TO ROUGH-IN.
D.ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C.
RUN CODE SIZE INSULATED EQUIPMENT GROUND CONDUCTOR.
E.EACH AND EVERY 125VAC THROUGH 250VAC RECEPTACLE SUPPLIED BY A
SINGLE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND,
50 AMPERES OR LESS, AND ALL THREE-PHASE RECEPTACLES RATED 150
VOLTS OR LESS TO GROUND, 100 AMPERES OR LESS INSTALLED IN
KITCHEN, FOOD PREPARATION, BAR AREAS AND RESTROOMS SHALL HAVE
A GROUND FAULT CIRCUIT-INTERRUPTER PROTECTED RECEPTACLE OR
RECEPTACLE(S) PROTECTED BY GFCI CIRCUIT BREAKER. ANY RECEPTACLE
INSTALLED WITHIN 6 FEET OF A SINK MUST BE G.F.C.I. TYPE.
F.FOR ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30
AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES TO BE
LOCATED:
A. NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE
RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, AND
B. NO LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE
RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, TO THE LEVEL OF
THE FINISHED FLOOR OR WORKING PLATFORM.
G. CIRCUIT NUMBERS ARE BASED ON CURRENT PANEL SCHEDULES. WHERE
CIRCUIT IS TO BE REPLACED OR RELOCATED, CONTRACTOR IS TO VERIFY
CORRECT NUMBERING AND UPDATE THE PANEL SCHEDULE.
H. ELECTRIC OUTLETS, SWITCHES, THERMOSTATS, FIRE ALARMS AND SIMILAR
DEVICES SHALL BE LOCATED A MINIMUM OF 15" ABOVE THE FINISHED
FLOOR, MEASURED TO THE BOTTOM OF THE BOX, AND A MAXIMUM OF 48"
ABOVE THE FINISHED FLOOR, MEASURED TO THE TOP OF THE BOX.
J. ALL PANEL CIRCUIT NUMBERS ARE FOR REFERENCE ONLY, AND ARE BASED
ON EXISTING PANEL SCHEDULES FOUND AT SITE. CONTRACTOR TO
PROVIDE AN UPDATED PANEL SCHEDULE TO OWNER UPON COMPLETION.
K.ELECTRIC WATER HEATERS MUST BE PROVIDED WITH A DISCONNECT. THE
CIRCUIT BREAKER MAY SERVE AS THIS DISCONNECT WHEN IT IS WITHIN
SIGHT OF THE WATER HEATER OR WHEN PROVIDED WITH A LOCK-ON /
LOCK OFF FEATURE.
REFERENCE NOTES
INDICATES POWER AND DATA OUTLETS FOR DIGITAL MENU BOARDS. REFER
TO DETAIL 1/I504 FOR ADDITIONAL INFORMATION.
INDICATES POWER AND DATA OUTLETS FOR ORDER STATUS BOARD. REFER
TO DETAIL 3/I504 FOR ADDITIONAL INFORMATION.
PROVIDE 2#8 & 1#10 EGC IN 3/4"C
PROVIDE 2#10 & 1#10 EGC IN 1/2" C
PROVIDE 2#6 & 1#10 EGC IN 3/4"" C
INDICATES ELECTRICAL CONNECTION FOR AIR CURTAIN.
1
2
3
4
5
6
POWER PLAN GENERAL NOTES
A-48
A 07/02/24 D/T AIR CURTAIN/ HAND SINK
STAMP DATE: 07/02/2024
Email: info@peccusa.com
Phone: 909.610.5364
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
2301 N Tustin Ave
#A8/22/2024
CEILING
ELEVATION - ELECTRICAL DIAGRAM
POWER AND DATA
RECEPTACLES AT 28"
(710MM) TO TOP OF
RECEPTACLE A.F.F.
SOFFIT
POWER AND DATA
RECEPTACLES AT 83"
(2030MM) TO TOP OF
RECEPTACLE A.F.F.
JBOX FOR
UNDERCABINET
LIGHTING
ELEVATION - ELECTRICAL DIAGRAM
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR
RECEPTACLE FOR
BLENDER(S)*
RECEPTACLE FOR
FUTURE USE
2-DATA PORT FOR
LABEL PRINTER
2-DATA PORT FOR
FUTURE USE
*BLENDER
QUANTITY BASED
ON EQUIPMENT
SCHEDULE
POWER AND DATA
RECEPTACLES AT 28"
(710MM) TO TOP OF
RECEPTACLE A.F.F.
UNDERCOUNTER
NITRO
REFRIGERATOR
RECEPTACLE FOR
UNDERCOUNTER
NITRO REFRIGERATOR
RECEPTACLE FOR
NITROGEN
GENERATOR
RECEPTACLE FOR
DPM TABLET
2-DATA PORT FOR
DPM TABLET AND
FUTURE USE
POWER AND DATA
RECEPTACLES AT 28"
(710MM) TO TOP OF
RECEPTACLE A.F.F.
POWER RECEPTACLE
FOR RINSE SINK AT
28" (710MM) TO TOP
OF RECEPTACLE
A.F.F.
UNDERCOUNTER REFRIGERATOR
UNDERCOUNTERNITROGEN
GENERATOR
PLAN - UPPER ELECTRICAL DIAGRAM
RECEPTACLE FOR
MILK DISPENSER
RECEPTACLE FOR
ICE DISPENSER
RECEPTACLE FOR
LABEL PRINTER
AND FUTURE USE
2-DATA PORT FOR
LABEL PRINTER
POWER AND DATA
RECEPTACLES AT 83"
(2100MM) TO TOP OF
RECEPTACLE A.F.F.
RECEPTACLE FOR
MILK DISPENSER
POWER AND DATA
RECEPTACLES AT 83"
(2100MM) TO TOP OF
RECEPTACLE A.F.F.
PLAN - ELECTRICAL DIAGRAM
2 2 2 2
2
20
0
1
0
B-
3
5
H
B-
3
3
A
B-
3
4
E
B-
4
0
A
B-
3
6
E
B-
4
0
23
4
1
9
A-
4
3
23
4
1
9
A-
4
3
17
5
6
4
B-
3
7
23
4
2
1
A-
4
3
G
B-
9
2
DEDICATED QUAD RECEPTACLE FOR DT
DIGITAL PRODUCTION MONITOR, UPS UNIT
(FOR TENDERING REGISTER EXPEDITOR,
POS AND PED) AND FUTURE USE
DEDICATED QUAD RECEPTACLE FOR
FUTURE USE
2-DATA J-BOX
4-DATA J-BOX
POWER AND DATA RECEPTACLES
DEDICATED QUAD RECEPTACLE FOR DRIVE
THRU TIMER MONITOR AND CONTROL UNIT.
(2) DEDICATED DUPLEX RECEPTACLE FOR
WIRELESS BASE AND SIGNAL PROCESSOR
WITH CIRCUIT ISOLATED GROUND
2-DATA J-BOX
SINGLE DATA J-BOX
POWER AND DATA RECEPTACLES
QUAD RECEPTACLE
FOR UNDERCOUNTER
REFRIGERATOR AND
FUTURE USE
POWER RECEPTACLE
UNDERCOUNTER
REFRIGERATOR
DUPLEX CONVENIENCE
POWER RECEPTACLE
EDGE OF COUNTERTOP
NOTE :EQUIPMENT SHOWN AS
DASHED LINES IS TO BE
FURNISHED AND INSTALLED
BY OWNER UNLESS NOTED
OTHERWISE
DRIVE THRU DIGITAL
PRODUCTION MONITOR
ELEVATION VIEW
DRIVE THRU TENDERING REGISTER
TRIPLE MONITOR MOUNT (GC INSTALLED)
SEE PLAN VIEW FOR MOUNTING LOCATION
POWER RECEPTACLES AT 28" (711MM) TO
TOP OF RECEPTACLE A.F.F.
DEDICATED QUAD RECEPTACLE FOR DT
DIGITAL PRODUCTION MONITOR, UPS UNIT
(FOR TENDERING REGISTER, EXPEDITOR
POS AND PED) AND FUTURE USE
DEDICATED QUAD RECEPTACLE FOR
FUTURE USE
2-DATA PORT FOR TENDERING REGISTER
AND EXPEDITOR POS
4-DATA PORT FOR DT VIDEO, PED AND/OR
CONNECT DEVICES
POS BANK (TYP)
CASH DRAWERS
ELEVATION VIEW
DRIVE THRU VIDEO CONDUIT FROM DT ORDER POINT TO
DT VIDEO DATA BOX AT 28" (711MM) A.F.F.
DRIVE THRU EXPEDITOR POS
RECEIPT PRINTER
DT AUDIO CONDUIT FROM
DRIVE THRU ORDER POINT
AND DETECTOR LOOP
CONDUIT FROM DT
WINDOW TO DT TIMER
CONTROL DATA JUNCTION
BOXES AT 8'-2" (2490MM)
POWER RECEPTACLE AT
28" (711MM) TO TOP OF
RECEPTACLE A.F.F.
QUAD RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR AND
FUTURE USE
SINGLE DOOR
REFRIGERATOR
DUPLEX CONVENIENCE
OUTLET AT 45" (1143MM) TO
TOP OF RECEPTACLE A.F.F.
DIMENSIONS INDICATE CENTER
MOUNTING POINT FOR MONITOR BASE
*
DRIVE THRU WIRELESS HEADSET
BASE STATION
DRIVE THRU TIMER MONITOR
DRIVE THRU TIMER CONTROL UNIT
POWER AND DATA RECEPTACLES AT 8'-2" (2490MM)
TO TOP OF RECEPTACLES A.F.F.
DEDICATED QUAD RECEPTACLE FOR DRIVE
THRU TIMER MONITOR AND CONTROL UNIT
(2) DEDICATED DUPLEX RECEPTACLE FOR
WIRELESS BASE AND SIGNAL PROCESSOR
WITH CIRCUIT ISOLATED GROUND
2-DATA PORT FOR DT TIMER AND CONTROL UNIT
SINGLE DATA PORT FOR DT AUDIO
(MIC & SPEAKER)
DRIVE THRU TIMER SIGNAL PROCESSOR (TSP)
36" W X 51" H (915MM W X 1295MM H) MIN. FIRE
RATED PLYWOOD BACKER BOARD. FASTEN TO
STRUCTURE. WALL FINISH TO CONCEAL.
FUTURE HHOP CABLING TO HEADSET BASE
STATION FROM J-BOX AT CLG/WALL FOR
EXTERNAL EXTENDED COVERAGE ANTENNA
(FOIO)
2 4
2
M
B-
4
4
E
B-
2
1
B-
4
5
B-
4
6
B-41
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
76085-018
<XX-XX-XXXX>
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
Revision Schedule
Rev Date By Description
E320
ELECLTRICAL
DETAILS
SCALE:3/4" = 1'-0"1 SIREN SYSTEM
SCALE:3/4" = 1'-0"2 DRIVE THRU EQUIPMENT
STAMP DATE: 04/13/2024
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
NOTE :EQUIPMENT SHOWN AS DASHED LINES IS TO BE FURNISHED
AND INSTALLED BY OWNER UNLESS NOTED OTHERWISE.
PLAN VIEW
ELEVATION VIEW
1
SECURE KEY BOX
CEILING HEIGHT SHOWN AT 96"
(2440MM). REFER TO REFLECTED
CEILING PLAN(S) FOR ACTUAL HEIGHT.
LOW VOLTAGE
CABLE BUNDLE
1 MUSIC SYSTEM
PLAY NETWORK
SPEAKERS
2" (50MM) Ø SLEEVE FOR LOW
VOLTAGE CABLE BUNDLE
MOUNTED TO (2) UNISTRUTS
CEILING TRIM RING
PRINTER
ROLLING CART
IPOD TOUCH
CHARGING CRADLE
CASH SCALE
HOME PHONE
CONNECT (HPC)
60" W X 70" H (1525MM W X
1780MM H) MIN. 3/4" FIRE
RATED PLYWOOD BACKER
BOARD. FASTEN TO
STRUCTURE TO HOLD MIN.
350 PSF. PAINTABLE
SURFACE ON ROOM SIDE &
FINISH AS SCHEDULED.
POWER, TELEPHONE & DATA
RECEPTACLES AT 12" (305MM) A.F.F.
TO CENTER OF GROUPING. SEE
FLAN VIEW NOTE "A" ABOVE FOR
DESCRIPTION.
POWER & DATA RECEPTACLES
AT 60" (1525MM) A.F.F. TO CENTER OF
GROUPING. SEE NOTE 'B ' ABOVE FOR
DESCRIPTION.
DESK
OFFICE PC
LAPTOP
SLEEVE FOR LOW VOLTAGE CABLE
BUNDLE MOUNTED TO (2) UNISTRUTS
ROLLING CART
SHELVING ABOVE POWER & DATA RECEPTACLES
(IN WALL, AT MUSIC SYSTEM SHELF)
(1) DUPLEX RECEPTACLE FOR:
MUSIC SYSTEM AMPLIFIER AND
FUTURE USE
(1) 2-DATA PORT FOR:
CURIO
POWER, TELEPHONE & DATA RECEPTACLES
(IN WALL, BELOW DESK)
(1) QUAD RECEPTACLE FOR:
PC, PRINTER, PHONE AND HPC
(1) QUAD RECEPTACLE FOR:
LAPTOP, CASH SCALE AND FUTURE USE
(1) QUAD RECEPTACLE
(1) PHONE MAIN
(1) 2-DATA PORT FOR:
PC AND PRINTER
DESK
A
B
WALL MOUNTED SHELVING UNIT
ATTACHED TO BACKER BOARD
CORDLESS 1 LINE PHONE
MUSIC SYSTEM PLAYER AND
AMPLIFIER (FURNISHED BY
OWNER, INSTALLED WITH
SPEAKER SYSTEM BY GC) ON
14" DEEP (355MM) SHELF ONLY
(MIN.)
56" W X 42" H (1420MM W X 1065MM H) MIN. 3/4"
FIRE RATED PLYWOOD BACKER BOARD. FASTEN
TO STRUCTURE TO HOLD MIN. 350 PSF.
PAINTABLE SURFACE ON ROOM SIDE AND FINISH
AS SCHEDULED.
MINI GROUND BAR FOR EQUIPMENT RACK. GC TO
COORDINATE RACK GROUNDING TO BAR WITH #6
GROUND WIRE AND PER JURISDICTIONAL
REQUIREMENTS
POWER & DATA RECEPTACLES AT 87" (2210MM)
A.F.F. TO CENTER OF GROUPING. SEE PLAN VIEW
NOTE "A" ABOVE FOR DESCRIPTION.
EQUIPMENT RACK WALL MOUNTED TO STRUCTURE
BY STARBUCKS VENDOR (GC TO COORDINATE
INSTALLATION). GROUND RACK PER MFR'S
ASSEMBLY INSTRUCTIONS. SEE EQUIPMENT RACK
SCHEDULE BELOW FOR EQUIPMENT INCLUDED
WITHIN.
PLAN VIEW
MOUNT GROUND BAR AT 116" (2945MM) A.F.F.
ELEVATION VIEW
(2) 2" (50 MM) Ø SLEEVES
FOR LOW VOLTAGE CABLE
BUNDLES MOUNTED TO
(2) UNISTRUTS
CEILING TRIM RING (TYP.)
ENLARGED VIEW
LAY-IN CEILING
UPS
IPS EQUIPMENT
ROUTER
EQUIPMENT RACK SCHEDULE
NETWORK SWITCH
PATCH PANEL
SECURITY RECORDER (NVR)
SECURITY KEYBOARD
PRODUCTION CONTROLLER DEVICES
NOTE :EQUIPMENT SHOWN AS DASHED
LINES IS TO BE FURNISHED AND
INSTALLED BY OWNER UNLESS
NOTED OTHERWISE.
MOUNT EQUIPMENT RACK AT 84" (2133MM) A.F.F.
76" (1930MM)
CLEAR AREA
BELOW FOR
TRASH
CONTAINERS,
STORAGE OR
DELIVERY
DROP OFF
WIRELESS MODEM AT 92"
(2335MM) A.F.F. STARBUCKS
VENDOR TO DETERMINE
OPTIMAL DEVICE LOCATION
DEMARC, IF REQUIRED
POWER AND DATA
RECEPTACLES AT 104"
(2642MM) A.F.F. TO
CENTER OF GROUPING.
SEE NOTE 'B ' ABOVE FOR
DESCRIPTION
SECURITY MONITOR
MOUNTED ON MONITOR
ARM (ATTACHED TO
BACKER BOARD).
BACK OF HOUSE CEILING
HEIGHT PER PLAN
21
6"
6"
4"
100MM
LOW VOLTAGE CABLE BUNDLES
SECURITY PANEL
FUTURE USE
- - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - -
1 SECURITY 2 POS
HIGH SPEED INTERNET
DEMARC EXTENSION
POS LAN
DT TIMER
SECURITY
CONTROL
ALARM PANEL
EMS DATA
CONCENTRATOR.
ALLOW 2" (50MM)
IN. CLEAR ABOVE
MAINTAIN 24" (610MM) MIN.
CLEARANCE FOR WHEN
EQUIPMENT RACK IS IN
OPEN ACCESS POSITION
(2) SLEEVES FOR
LOW VOLTAGE CABLE
BUNDLES MOUNTED
TO (2) UNISTRUTS
EQUIPMENT RACK
POWER & DATA RECEPTACLES
(IN WALL, ABOVE SHELVES)
(1) QUAD RECEPTACLE FOR:
EMS DATA CONCENTRATOR
(1) DUPLEX RECEPTACLE FOR:
SECURITY CONTROL ALARM PANEL
(1) 2-DATA PORT FOR:
EMS DATA CONCENTRATOR
B
A POWER RECEPTACLES
(IN WALL, BEHIND OF EQUIPMENT RACK)
(1) INDIVIDUAL BRANCH CIRCUIT RECEPTACLE FOR:
UPS
(1) DUPLEX RECEPTACLE FOR:
PDU STRIP AND FUTURE USE
IOT GATEWAY
2
2
2
B-26
B-24
B-30B-22
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
76085-018
<XX-XX-XXXX>
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
Revision Schedule
Rev Date By Description
E330
ELECTRICAL
DETAILS
SCALE:3/4" = 1'-0"1 MANAGER'S DESK
SCALE:3/4" = 1'-0"2 EQUIPMENT RACK
STAMP DATE: 04/13/2024
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
76085-018
<XX-XX-XXXX>
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
Revision Schedule
Rev Date By Description
E500
SINGLE LINE DIAGRAM
AND PANEL SCHEDULES
SCALE:NONE1PANEL SCHEDULES
REFERENCE NOTES
EXISTING PANEL WITH REVISED LOADS. REFER TO PANEL SCHEDULE THIS SHEET.
ALL NEW CIRCUIT BREAKERS INSTALLED WITHIN PANELBOARD SHALL MATCH THE
HIGHEST EXISTING AIC RATED BREAKERS WITHIN PANELBOARD. INSPECTOR TO
VERIFY AT SITE.
THE CONTRACTOR SHALL VERIFY THE METER/MAIN OVERCURRENT PROTECTION
DEVICE'S MANUFACTURER AND PART NUMBER.
CIRCUIT BREAKERS IN ALL DOWNSTREAM PANELS SHALL BE FROM THE SAME
MANUFACTURER OF METER/MAIN OVERCURRENT PROTECTION DEVICE. CIRCUIT
BREAKER AIC RATING SHALL MATCH OR EXCEED SERVICE AVAILABLE FAULT
CURRENT. OTHERWISE, PROVIDE MAIN BREAKER AS SHOWN ON PANEL SCHEDULE
PER CIRCUIT BREAKER MANUFACTURER'S SERIES-RATING CHART.
THE CONTRACTOR SHALL FIELD VERIFY SERVICE EQUIPMENT'S AVAILABLE FAULT
CURRENT BEFORE ISSUING ANY BID. NOTIFY ELECTRICAL ENGINEER IMMEDIATELY
IF MAJOR DISCREPANCIES OCCUR
THE EQUIPMENT SHALL BE LEGIBLY MARKED IN THE FIELD TO INDICATE A SERIES
COMBINATION RATING WHICH SHALL BE READILY VISIBLE. CONTRACTOR TO AFFIX
SERIES COMBINATION RATING LABEL SIMILAR TO AS SHOWN ON DETAIL 3/E500.
1
2
3
4
SCALE:NONE1SINGLE LINE DIAGRAM
SCALE:NONE3MANUFACTURER'S SERIES RATING CHART
SERIES COMBINATION SYSTEM
RATED 65,000 AMPERES.
IDENTIFIED REPLACEMENT
COMPONENTS REQUIRED.
CAUTION
TO EXISTING
UTILITY TRANSFORMER
(E) SERVICE ENTRANCE EQUIPMENT
1200A, 120/208V, 3ɸ-4W, 65kAIC
U.G.P.S.
G
N
(E)
600A
3P
1200A BUS
(E)
1200A
3P
3
2
(E)
MLO
A
600A
M
(E)
MLO
B
600A
(E
)
(E)
STAMP DATE: 04/13/2024
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
76085-018
<XX-XX-XXXX>
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
Revision Schedule
Rev Date By Description
E600
INTERIOR LIGHTING
COMPLIANCE CERT
STAMP DATE: 04/13/2024
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
76085-018
<XX-XX-XXXX>
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
Revision Schedule
Rev Date By Description
E610
INTERIOR LIGHTING
COMPLIANCE CERT
STAMP DATE: 04/13/2024
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
76085-018
<XX-XX-XXXX>
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
Revision Schedule
Rev Date By Description
E620
INTERIOR LIGHTING
COMPLIANCE CERT
STAMP DATE: 04/13/2024
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
ABBREVIATIONS
ABOVE FINISHED FLOOR
PLUMBING SYMBOL LEGEND
AFF
AHJ AUTHORITIES HAVING JURISDICTION
APPROX APPROXIMATE
BLDG BUILDING
CLG CEILING
CONST CONSTRUCTION
CW DOMESTIC COLD WATER
CXA COMMISSIONING AGENT
DEG DEGREES
DN
DTL
EC
DOWN
DETAIL
DWG(S) DRAWING(S)
EA EACH
ELECTRICAL CONTRACTOR
ELEC ELECTRICAL
EMER EMERGENCY
EXIST EXISTING
EXT EXTERIOR
FD
FS
F&I
FLOOR DRAIN
FLOOR SINK
FURNISH & INSTALL
FOIC FURNISHED BY OWNER,
INSTALLED BY CONTRACTOR
FOIO FURNISHED BY OWNER,
INSTALLED BY OWNER
FLR
FT
FLOOR
FOOT/FEET
FCO FLOOR CLEANOUT
GC
HR HOUR
HVAC HEATING, VENTILATION, AND AIR
CONDITIONING
HW HOT WATER
HS HANDSINK
HWS HOT WATER SUPPLY
HWR HOT WATER RETURN
LL
LV
LANDLORD
LOW VOLTAGE
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL, AND PLUMBING
MFG MANUFACTURER
MIN MINIMUM
MS MOP SINK
NL
NTS
PC
PS
NIGHTLIGHT
NOT TO SCALE
PLUMBING CONTRACTOR
PREP SINK
POC POINT OF CONNECTION
REF REFERENCE
REQ’D REQUIRED
REV REVISION
SHT
SF
TEL
SHEET
SQUARE FEET
SPECS SPECIFICATION(S)
SST STAINLESS STEEL
TELEPHONE
TEMP TEMPORARY
TMV
TYPICAL
UC
TEMPERATURE MIXING VALVE
TW TEMPERED HOT WATER
TYP
UNDER COUNTER
UNO UNLESS NOTED OTHERWISE
V VENT
W SANITARY WASTE
WCO WALL CLEANOUT
WH WATER HEATER
WP WEATHER PROOF
APPLICABLE CODES
CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE STATE CODES
WHETHER INDICATED HEREIN OR NOT.
2022 CALIFORNIA BUILDING STANDARDS CODE:
• PART 1 - CALIFORNIA ADMINISTRATIVE CODE (CAC)
• PART 2 - CALIFORNIA BUILDING CODE (CBC)
• PART 3 - CALIFORNIA ELECTRICAL CODE (CEC)
• PART 4 - CALIFORNIA MECHANICAL CODE (CMC)
• PART 5 - CALIFORNIA PLUMBING CODE (CPC)
• PART 6 - CALIFORNIA ENERGY CODE (CENC)
• PART 7 - (CURRENTLY VACANT)
• PART 8 - CALIFORNIA HISTORICAL BUILDING CODE (CHBC)
• PART 9 - CALIFORNIA FIRE CODE (CFC)
• PART 10 - CALIFORNIA EXISTING BUILDING CODE (CEBC)
• PART 11 - CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN)
• PART 12 - CALIFORNIA REFERENCE STANDARDS CODE
FS
M WM
POC
FLOOR SINK
WATER METER
CONNECT TO EXISTING
F. ALL DOMESTIC WATER HEATING, RECIRCULATING, FILTER AND
SOFTENING EQUIPMENT SHALL BE TESTED AND/OR ADJUSTED
AND BALANCED BY THE CONTRACTOR'S TESTING, ADJUSTING
AND BALANCE AGENT (SEE TESTING ADJUSTING AND BALANCING)
OR THE MANUFACTURER'S CERTIFIED STARTUP
REPRESENTATIVE AFTER THE SYSTEM IS VERIFIED TO BE
COMPLETE AND CORRECT BY STARBUCKS CXA IN ACCORDANCE
WITH THE REQUIREMENTS OF THESE DOCUMENTS. SEQUENCES
OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY
OPERATE IN ACCORDANCE WITH THE CONTRACT
REQUIREMENTS. DELIVERABLES: PRELIMINARY, WRITTEN
FUNCTIONAL PERFORMANCE REPORT CONFORMING TO THE
REQUIREMENTS SPECIFIED HEREIN, DOCUMENTING THE
INFORMATION SPECIFIED, ETC. TO THE STARBUCKS CXA
IMMEDIATELY UPON COMPLETION OF THE WORK.
G. CONTRACTOR SHALL INFORM STARBUCKS CXA WHEN
EQUIPMENT IS READY FOR FUNCTIONAL PERFORMANCE
TESTING. ALL EQUIPMENT SHALL BE READY FOR FUNCTIONAL
PERFORMANCE TESTING PRIOR TO STARTING TESTING.
CONTRACTOR SHALL OPERATE EQUIPMENT FOR STARBUCKS
CXA AND VERIFY BY DEMONSTRATION THE CORRECT OPERATION
OF EQUIPMENT, RESPONSE OF SENSORS, AND PROPER
EXECUTION OF HVAC CONTROL AND LIGHTING SEQUENCES;
INCLUDING BUT NOT LIMITED TO, AIR MOVEMENT, TEMPERATURE,
SOUND, AND CONTROL RESPONSE. PROVIDE ANY SECURITY
ACCESS, HARDWARE, SOFTWARE, OR OTHER SUPPORT AS
NEEDED FOR THE STARBUCKS CXA TO EFFICIENTLY WITNESS
AND DOCUMENT ALL EQUIPMENT TESTING. STARBUCKS CXA
WILL RECORD THE EQUIPMENT OPERATION AND RESPONSE TO
TESTING SEQUENCES AND PREPARE A LIST OF ANY
DEFICIENCIES DISCLOSED BY THE FUNCTIONAL PERFORMANCE
TESTS FOR CORRECTION BY THE CONTRACTOR. EQUIPMENT
INCLUDES, BUT IS NOT LIMITED TO, AIR HANDLING UNITS,
ROOFTOP AND SPLIT TYPE, CONDENSING UNITS, EXHAUST FANS,
LIGHTING CONTROLS, ETC. DELIVERABLES: PROVIDE COMPLETED
COPIES OF ALL START UP REPORTS, FILLED OUT ON THE
MANUFACTURER'S FORMS, TO THE STARBUCKS CXA.
H. CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ISSUES
OR DEFICIENCIES DISCLOSED DURING THE FUNCTIONAL
PERFORMANCE TESTING PROCESS. CORRECTIONS SHOULD BE
MADE IN A TIMELY MANNER WITHOUT DISRUPTION TO THE
SYSTEM AND CONSTRUCTION SCHEDULE.
I. CONTRACTOR SHALL BE READILY AVAILABLE FOR ANY RE-
TESTING OF EQUIPMENT DEEMED NECESSARY BY STARBUCKS
CXA DURING INSTALLATION VERIFICATION AND FUNCTIONAL
PERFORMANCE TESTING. CONTRACTOR IS RESPONSIBLE FOR
CORRECTING ANY ISSUES OR DEFICIENCIES FOUND IN THE
SYSTEM DURING ANY AND ALL RE-TESTING. CORRECTIONS
SHOULD BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION TO
THE SYSTEM AND CONSTRUCTION SCHEDULE. DELIVERABLES:
FINAL BALANCE REPORT, DEFICIENCIES LIST NOTING
CORRECTIVE ACTIONS PERFORMED BY CONTRACTOR IN
RESPONSE TO INSTALLATION VERIFICATION AND FUNCTIONAL
PERFORMANCE TEST RESULTS.
J. CONSTRUCTION AND POST CONSTRUCTION TESTING:
ADDITIONAL TESTING MAY BE REQUIRED BY LEED AND OTHER
PROCESSES THAT MAY OCCUR OUT OF SEQUENCE WITH
COMMISSIONING SERVICE. CONTRACTOR SHALL CONDUCT,
DOCUMENT, SUPPORT AND SCHEDULE THIS TESTING AS
DIRECTED BY STARBUCKS CXA.
FCO
WCO WALL CLEANOUT
FLOOR CLEANOUT
GENERAL CONTRACTOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GW GREASE WASTE
S
SHOCK ABSORBER
STRAINER
HB HOSE BIBB
D. INSTALLATION VERIFICATION SHALL BE PERFORMED BY
STARBUCKS CXA. CONTRACTOR SHALL SUPPORT STARBUCKS
CXA INSTALLATION VERIFICATION EFFORTS AS NECESSARY.
PROVIDE ALL ACCESS AND EQUIPMENT NECESSARY FOR
STARBUCKS STAFF TO VERIFY THAT THE EQUIPMENT IS
INSTALLED CORRECTLY.
E. CONTRACTOR SHALL BE READILY AVAILABLE DURING
INSTALLATION VERIFICATION TO CORRECT ANY DEFICIENCIES OR
DEFECTS DISCLOSED BY THE INSTALLATION VERIFICATION
PROCESS. CORRECTIONS SHALL BE MADE IN A TIMELY MANNER
WITHOUT DISRUPTION OF THE CONSTRUCTION SCHEDULE.
CH. V
RV
CHECK VALVE
RELIEF VALVE
BV
GV
BALL VALVE
GATE VALVE
TW
RO
RD
G
RS
TW
RO
G
RD
RS
TEMPERED WATER
REVERSE OSMOSIS WATER
GAS PIPING
REFRIGERANT DISCHARGE PIPING
REFRIGERANT SUCTION PIPING
GW
CD
S OR W
S OR W
V
CD
GW
CW
HW
CWF
CWN
CWS
CWF
CWN
CWS
SANITARY OR WASTE PIPING ABOVE SLAB
SANITARY OR WASTE PIPING BELOW SLAB
CONDENSATE DRAIN
VENT PIPING
HOT WATER PIPING
GREASE WASTE
COLD WATER PIPING
COLD WATER FILTERED
COLD WATER NANO FILTERED
COLD WATER SOFTENED
SYSTEM COMMISSIONING
CONTRACTOR RESPONSIBILITIES FOR BUILDING COMMISSIONING
CONTRACTOR SHALL PROVIDE SUPPORT AND WORK AS SPECIFIED,
NEEDED AND REQUIRED TO CONDUCT AND FACILITATE STARBUCKS
STAFF BUILDING COMMISSIONING EFFORTS. THIS WORK WILL BE
COMPRISED OF THREE DISTINCT EFFORTS:
1) SUPPORT STARBUCKS COMMISSIONING AGENT (CXA) DURING
INSTALLATION VERIFICATION AND CORRECT DISCLOSED
DEFICIENCIES;
2) PERFORM TESTING, ADJUSTING, BALANCING AND SYSTEM STARTUP
AND SUPPORT FUNCTIONAL PERFORMANCE TESTING BY STARBUCKS
CXA;
3) CORRECT DEFICIENCIES DISCLOSED BY FUNCTIONAL PERFORMANCE
TESTING AND SUBMIT REPORTS. CONTRACTOR SHALL PERFORM AND
PROVIDE THE FOLLOWING:
A. SYSTEMS SUBJECT TO COMMISSIONING MAY INCLUDE, BUT ARE
NOT LIMITED TO, DOMESTIC HOT WATER GENERATION.
B. CONTRACTOR SHALL INCLUDE COMMISSIONING ACTIVITIES IN
PROJECT SCHEDULE AND SHOW INTERVALS FOR PERFORMANCE
OF WORK FOR WHICH CONTRACTOR IS RESPONSIBLE AND
INTERVALS FOR WORK PERFORMED BY STARBUCKS CXA.
CONTRACTOR SHALL SHOW RESOURCES FOR PERFORMING ALL
WORK RELATED TO COMMISSIONING ACTIVITIES ON A LINE ITEM
IN THE SCHEDULE OF VALUES.
C. CONTRACTOR SHALL INSTALL EQUIPMENT IN ACCORDANCE WITH
THE MANUFACTURER’S REQUIREMENTS AND ALL CONTRACT
DOCUMENTS. ENSURE THAT ALL EQUIPMENT IS INSTALLED
TOTALLY COMPLETE, AND ACCESSIBLE TO STARBUCKS CXA FOR
INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE
TESTING PRIOR TO THE SCHEDULED START OF INSTALLATION
VERIFICATION.
VALVES
GENERAL
INSTALL VALVES FOR EACH FIXTURE AND ITEM OF EQUIPMENT. PROVIDE
BRAIDED STAINLESS STEEL HOSE (UNLESS OTHERWISE NOTED) BETWEEN
VALVE AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS. LOCATE SHUT-OFF VALVES ADJACENT TO EQUIPMENT
FOR EASY ACCESS SUCH THAT VALVES CAN BE REACHED WITHOUT
MOVING EQUIPMENT. SHUT OFF VALVES TO BE BALL TYPE. VALVES SHALL
BE LISTED/APPROVED FOR USE PER AUTHORITIES HAVING JURISDICTION
(AHJ) AND CODE REQUIREMENTS. PROVIDE VALVE IDENTIFICATION PER
THE PROJECT MANUAL FOR MAIN WATER SERVICE SHUT-OFF AND ANY
OTHER VALVES WHICH ARE NOT CLEARLY EVIDENT WHAT THEY SERVE.
PLUMBING FIXTURES
WATER HEATER
SIZE WATER HEATER PER STARBUCKS STANDARD AND PER AUTHORITIES
HAVING JURISDICTION (AHJ), WHICHEVER IS MORE STRINGENT. PROVIDE
INSTALLATION COMPLETE WITH FITTINGS AS SHOWN IN THE DRAWINGS.
SET HOT WATER TEMPERATURE AT 140° F OR ADJUST AS REQUIRED BY AHJ.
PROVIDE THERMOMETER ON HOT WATER PIPE LEAVING WATER HEATER.
WATER FILTRATION
STARBUCKS WATER FILTRATION VENDOR WILL PROVIDE FILTRATION
SYSTEM. CONTRACTOR SHALL CONFIRM WITH STARBUCKS CONSTRUCTION
MANAGER WHETHER VENDOR OR PLUMBING CONTRACTOR IS TO INSTALL
FILTRATION SYSTEM. PROVIDE AND COORDINATE INSTALLATION COMPLETE
WITH ALL PIPING, FITTINGS, AND EQUIPMENT AS INDICATED ON THE
DRAWINGS.
CONNECTIONS
THE PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO
EQUIPMENT INCLUDING REQUIRED MATERIAL SUCH AS PIPING, VALVES,
FILTERS, TRAPS, CHECKS VALVES, VACUUM BREAKERS, AND FLEXIBLE AND
RIGID TUBING.
SCHEDULES
REFER TO SCHEDULES ON DRAWINGS FOR A DESCRIPTION OF LISTED ITEMS
AND FURNISH ANY AND ALL PLUMBING FIXTURES LISTED AS "GC". ANY
DISCREPANCIES ABOUT WHO IS TO PROVIDE PLUMBING FIXTURES IN THE
SCHEDULE SHALL BE BROUGHT TO STARBUCKS ATTENTION FOR
CLARIFICATION.
SUPPLIES.
INSTALL ALL FIXTURES LISTED REGARDLESS OF WHO
DISHWASHER
G.C. TO FURNISH AND INSTALL POWER CORD FOR DISHWASHER PER
JURISDICTIONAL REQUIREMENTS.IF EQUIPMENT IS SPECIFIED AS
HOBART ADVANSYS, THE UNIT IS TO BE PLUMBED WITH COLD, NON-
FILTERED WATER.IF THE WATER FILTRATION SYSTEM IS A PENTAIR
CONFIGURATION II OR III, THEN THE COLD, NON-FILTERED WATER MUST
ALSO BE SOFTENED.
INSULATION
WATER PIPING
PROVIDE THERMAL INSULATION PER THE SPECIFICATIONS.
SAFETY COVERS
FURNISH AND INSTALL SPECIFIED NO SCALD SAFETY COVERS WITH
INSULATED FOAM LINER AND TAMPER PROOF STRAP AT ALL EXPOSED ADA
SINK P-TRAPS AND WATER SUPPLIES AND AS REQUIRED BY JURISDICTION .
PIPING
CONDENSATE DRAINAGE PIPING
THE PLUMBING CONTRACTOR SHALL PROVIDE CONDENSATE DRAINS
FOR AIR HANDLING UNITS AND STARBUCKS EQUIPMENT (REFER TO
SCHEDULE). CONDENSATE DRAINAGE PIPING SHALL BE TYPE "M"
COPPER TUBING WITH WROUGHT COPPER SWEAT FITTINGS JOINED
WITH 50/50 SOLDER.
TESTING
ALL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE THEY
ARE
BACKFILLED OR CONCEALED. AFTER TESTING IS COMPLETE, THE
PLUMBING
CONTRACTOR SHALL DISINFECT THE POTABLE WATER SYSTEM AS
REQUIRED BY LOCAL AUTHORITY. TEST WATER PURITY ACCORDING TO
LOCAL REQUIREMENTS AND SUBMIT CERTIFIED TEST RESULTS TO
ENGINEER FOR REVIEW AND APPROVAL.
CARBONATION
IF APPLICABLE TO PROJECT SCOPE FOR CBE STATION, STARBUCKS
CARBONATION VENDOR WILL PROVIDE AND INSTALL EQUIPMENT, CO2
TANKS AND FITTINGS. STARBUCKS SHALL PROVIDE AND CONTRACTOR
SHALL INSTALL CO2 TANK MOUNTING BRACKET, PROTECTIVE SHELVING
UNIT AND CO2 GAS TUBING AS SHOWN ON DRAWINGS AND PER
MANUFACTURER’S INSTRUCTIONS. MAXIMUM TUBING LENGTH
INCLUDING COILED ENDS IS 100 FT (30 M) AND MAXIMUM BEND IS TO 3
INCH (75 MM) MINIMUM RADIUS. ROUTE CO2 TUBING PREFERABLY
THROUGH WALL AND/OR CEILING CAVITIES, WITHOUT KINKS AND SO AS
TO NOT TOUCH ANY HOT SURFACE (BALLAST, STEAM PIPE, ETC.) OR RUB
AGAINST A SHARP EDGE THAT MAY ABRADE OR CUT TUBING. ALL HOLES
MUST BE SEALED WITH A GROMMET OR ESCUTCHEON. TUBING IS TO BE
SECURED TO APPROPRIATE PERMANENT SURFACES TO KEEP IT OFF THE
FLOOR OR CABINET BOTTOMS AND AWAY FROM OTHER EQUIPMENT.
LABEL BOTH ENDS OF TUBING AND REGULARLY AT TEN (10) FOOT
INTERVALS ALONG ROUTE AS “CO2.”
NITROGENATION
STARBUCKS NITROGENATION VENDOR WILL PROVIDE AND INSTALL
EQUIPMENT AND FITTINGS IF APPLICABLE TO PROJECT SCOPE FOR
NITRO STATION. GENERAL CONTRACTOR SHALL COORDINATE NITRO
SYSTEM INSTALLATION WITH STARBUCKS VENDOR.
GENERAL PLUMBING NOTES
1. PLUMBING CONTRACTOR SHALL COORDINATE WITH THE GENERAL
CONTRACTOR TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS,
CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY
BECOME DAMAGED DURING THE COURSE OF WORK.
2. EXPOSED/SURFACE MOUNTED PIPING IS ONLY ALLOWED IN THE BAR
AREA UNDER COUNTERTOPS, WHERE IT DOES NOT OBSTRUCT
CABINETS/DEVICES AND WHERE APPROVED BY STARBUCKS
CONSTRUCTION MANAGER. IF ROUTED THROUGH CABINETS, IT
SHALL BE ROUTED TO MAXIMIZE STORAGE SPACE AND BE
PROTECTED FROM DAMAGE.
3. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR
ARRANGEMENT OF SYSTEM(S). FURNISH AND INSTALL ALL
COMPONENTS NEEDED WHETHER INDICATED OR NOT TO PROVIDE A
COMPLETE AND OPERATING SYSTEM. OVERALL CASEWORK
COMPONENT DIMENSIONING ON PLUMBING DETAILS ARE SHOWN
FOR REFERENCE AND COORDINATION ONLY.
4. CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES
REQUIRED BY OTHER TRADES, AND NOTIFY STARBUCKS
CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO
PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE
OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL
DIMENSIONS TO BE TAKEN FROM ACTUAL BUILDING DIMENSIONS.
5. THE PLUMBING CONTRACTOR SHALL COORDINATE PLUMBING WORK
WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS AND
SPECIFICATIONS SHALL TAKE PRECEDENCE OVER ALL OTHER
DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR FIXTURES IN
CASEWORK AND PLUMBING DETAILS. SEE THE PROJECT MANUAL
FOR PLUMBING SPECIFICATION SECTIONS.
6. ALL PIPING AND/OR PLUMBING DEVICES SHALL BE SUPPORTED FROM
STRUCTURE (NOT FROM HVAC DUCTS OR OTHER PIPES/CONDUITS).
7. WHEN BUNDLING SEVERAL INDIRECT WASTE LINES TO DRAIN INTO
FLOOR SINK, A UNISTRUT IS REQUIRED FOR SECURING AND BRACING
ALL LINES ABOVE THE DRAIN.
8. FURNISH AND INSTALL ALL NEEDED DRAIN LINES PER CODE (NOT ALL
SHOWN).INSTALL DRAINS AT 2% SLOPE WHERE POSSIBLE WITHOUT
DIPS OR SAGS. ALL INDIRECT DRAINS SHALL RUN SEPARATELY
FROM EACH OTHER TO INDIRECT DRAIN RECEPTOR AND SHALL
TERMINATE WITH AN AIR GAP PER CODE.
9. FURNISH AND INSTALL WALL CLEANOUTS AT ALL SINKS AND AS
NEEDED PER CODE (NOT ALL SHOWN).
10. INSULATE ICE BIN DRAINAGE PIPES PER THE REQUIREMENTS IN THE
PROJECT MANUAL.
GENERAL NOTES
SCOPE
THE INTENT OF THE PROJECT MANUAL AND THE DRAWINGS IS TO
PROVIDE A COMPLETE AND FULLY OPERATIONAL PLUMBING SYSTEM.
THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, AND
EQUIPMENT RELATED TO THE INSTALLATION OF THE PLUMBING WORK.
SITE EXAMINATION
THE CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE
FIXTURES, EQUIPMENT, AND PIPING WILL BE INSTALLED AND WILL
REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION
OF THE PLUMBING WORK.
STANDARDS
EQUIPMENT AND MATERIALS SHALL CONFORM WITH THE APPROPRIATE
PROVISIONS OF LISTING STANDARD IN EFFECT AS APPLICABLE TO EACH
INDIVIDUAL UNIT OR ASSEMBLY.
CODES
ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL
APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE
OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE
CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE
CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM
STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS.
PERMITS AND FEES
THE CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES,
AND INSPECTIONS NECESSARY TO COMPLETE THE PLUMBING WORK.
WARRANTY
THE CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO
BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD
OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY
STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK
PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING
WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS
AND WORKMANSHIP.
LANDLORD REQUIREMENTS
PRIOR TO BID: THE CONTRACTOR SHALL COORDINATE WITH LANDLORD /
BUILDING OWNER FOR ANY CONSTRUCTION REQUIREMENTS.
CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH
REQUIREMENTS AND ADHERE TO THEM. WHERE LANDLORD / BUILDING
OWNER REQUIREMENTS ARE MORE STRINGENT THAN SHOWN IN THESE
PLANS. LANDLORD / BUILDING OWNER REQUIREMENTS SHALL GOVERN.
WATER HAMMER ARRESTORWHA
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
Revision Schedule
Rev Date By Description
March 24
CH
E
C
K
S
E
T
-
0
3
/
2
2
/
2
0
2
4
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
76085-018
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
PLUMBING GENERAL
NOTES & LEGENDS
P-001
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
5
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
Revision Schedule
Rev Date By Description
March 24
CH
E
C
K
S
E
T
-
0
3
/
2
2
/
2
0
2
4
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
76085-018
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
PLUMBING SCHEDULES
& CALCULATIONS
P-002
NOTE: ADDITIONS OR ALTERATIONS OR NEW PLUMBING FIXTURES AND
FITTINGS SHALL NOT EXCEED THE MAXIMUM ALLOWABLE FLOW RATES
SPECIFIED IN SECTION 5.303.
MAXIMUM FIXTURE FLOW RATES
(CGBSC SECTION 5.303.3)
MAXIMUM FLOW RATE
NONRESIDENTIAL LAVATORY FAUCETS 0.4 GPM @ 60 PSI
KITCHEN FAUCETS 1.6 GPM @ 60 PSI
METERING FAUCETS 0.2 GALLONS/CYCLE
WATER CLOSETS 1.28 GALLONS/FLUSH
DC
5030
61-113
B
12-32
5010
A
1-11
5005
FIXTURE UNITS
HYDROTROL
J.R. SMITH
WHA SYMBOL
33-60
5020
EQUAL
OR APPROVED
WATER HAMMER ARRESTER SCHEDULE
ELECTRIC WATER HEATER SCHEDULE (EXISTING)
TAG QTY MANUFACTURE MODEL CAPACITY
(GALLON)
ELEMENT
WATTAGE
RECOVERY
@90°F RISE
(GPH)
VOLTAGE(V)
CONNECTION OPERATING
WEIGHT
(LBS)
CW HW
(E) EWH-1 1 AO SMITH DRE-52-100 50 18,000 82 208 1"1"120
MARK
WCO
FCO
GCO
TMV
NOTES:
1. CONTRACTOR TO VERIFY THAT ALL PLUMBING FIXTURES ARE FOR INSTALLATION ON EXPOSED SLAB.
2. ALL FIXTURES ARE SUBJECT TO TENANT/ARCHITECT APPROVAL.
3. REFER TO ARCHIECT PLANS FOR COMPLETE LIST OF PLUMBING FIXTURES.
FIXTURE
W
WALL
CLEANOUT
FLOOR
CLEANOUT
GRADE
CLEANOUT
THERMOSTATIC
MIXING VALVE
SEE -
PLANS
SEE -
PLANS
SEE -
PLANS
--1/2"1/2"
--
--
--
ZURN WALL CLEANOUT MODEL Z1441-VP, DURA-COATED CAST IRON BODY, GAS AND WATERTIGHT,
VANDAL PROOF SCREWS, OR EQUIVALENT. COORDINATE FINAL LOCATIONS AND FINISH WITH
ARCHITECT.
ZURN FLOOR CLEANOUT MODEL Z1400-VP, ADJUSTABLE LEVELING, GAS AND WATERTIGHT, VANDAL
PROOF SCREWS, OR EQUIVALENT. COORDINATE FINAL LOCATIONS AND FINISH WITH ARCHITECT.
ZURN GRADE CLEANOUT MODEL Z1400-DC, HEAVY DUTY, ADJUSTABLE LEVELING, GAS AND
WATERTIGHT, VANDAL PROOF SCREWS, OR EQUIVALENT. COORDINATE FINISH WITH ARCHITECT.
SYMMONS MAXLINE THERMOSTATIC MIXING VALVE MODEL 7-210-CK-D, W/ INTEGRAL CHECK VALVES
AND WALL MOUNTING BRACKET, ASSE 1017 AND ASSE 1070 COMPLIANT. PROVIDE DIAL TYPE
THERMOMETER ON TEMPERED WATER LINE AT TMV OULET AND SET @ 110°F.
FIXURE ROUGH-IN
DESCRIPTION
ACCESSORY SCHEDULE
V CW HW
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
5
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
Revision Schedule
Rev Date By Description
March 24
CH
E
C
K
S
E
T
-
0
3
/
2
2
/
2
0
2
4
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
76085-018
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
PLUMBING SCHEDULES
& CALCULATIONS
P-003
TY
P
E
"
K
"
C
O
P
P
E
R
PE
X
TY
P
E
"
M
"
C
O
P
P
E
R
TY
P
E
"
L
"
C
O
P
P
E
R
DW
V
C
O
P
P
E
R
SC
H
1
0
S
T
A
I
N
L
E
S
S
PV
C
S
C
H
E
D
U
L
E
4
0
SC
H
4
0
B
L
A
C
K
S
T
E
E
L
NO
-
H
U
B
C
A
S
T
I
R
O
N
GR
O
O
V
E
D
T
Y
P
E
L
C
O
P
P
E
R
PIPE MATERIAL SCHEDULE
LEGEND
B = BARE PIPE
I = INSULATED
H = HEAT TRACED
SERVICE
DOMESTIC WATER
DOMESTIC HOT WATER
NATURAL GAS
MEDIUM PRESSURE GAS
WASTE
VENT
STORM DRAIN
OVERFLOW DRAIN
TRAP PRIMER
CONDENSATE
GREASE WASTE
ABOVE GRADE
ABOVE GRADE
BELOW GRADE
LOCATION
BELOW GRADE
INSIDE, 4" & SMALLER
INSIDE, 5" & LARGER
INSIDE, 4" & SMALLER
INSIDE, 5" & LARGER
ABOVE GRADE
ABOVE GRADE
BELOW GRADE
INSIDE
BELOW GRADE
ABOVE INSIDE
BELOW GRADE
INSIDE
BELOW GRADE B
B
B
B
B
B
B
I
I
B
N/A
B
B
B
B
N/A
N/A
MATERIALS ADDITIONAL COMMENTS
INSTALL 75 GPM (SCHIER GB-75) GREASE
INTERCEPTOR WITH SAMPLING BOX.
MARK
GI-1
NOTES :
1. 4" PLAIN END INLET / OUTLET.
2. MAXIMUM OPERATING TEMPERATURE: 140 F CONTINUOUS
3. BUILT-IN FLOW CONTROL OR PROVIDE FLOW CONTROL DEVICE AS PER THE PLAN.
4. COVER PLACEMENT ALLOWS FULL ACCESS TO TANK FOR PROPER MAINTENANCE.
5. ENGINEERED INLET AND OUTLET DIFFUSERS ARE REMOVABLE TO INSPECT / CLEAN PIPING.
6. INTEGRAL AIR RELIEF / ANTI-SIPHON.
7. SIZING AND MODEL NUMBER ARE BASED ON TENANT'S REQUIREMENT.
31 GALLONS 125 GALLONS
FLOW RATE
(GPM)LOCATION
75 REFER TO SHEET PS-100
FOR EXACT LOCATION.
PIPE
CONNECTION
4 INCH
MANU
SCHIER GB-75 47" X 33" X 40"
HYDRO-MECHANICAL GREASE INTERCEPTOR SCHEDULE
WEIGHT (LBS)
190
SAMPLING BOX SPECIFICATION
PROVIDE SCHIER MAKE SAMPLE BOX MODEL SV10
FLOW CONTROL DEVICE SPECIFICATION
PROVIDE ENDURA MAKE FLOW CONTROL
DEVICE MODEL 4044275A OR EQUALS BY
OWNER APPROVAL.
SOLIDS
CAPACITY
LIQUID
CAPACITY MODEL SIZE ( L X W X H)
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
5
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
RETAIL
SEATING
AREA
UNISEX
CUSTOMER
RESTROOM
UNISEX
PARTNER
RESTROOM
PARTNER /
MANAGER
AREA
BACKBAR
WORKROOM
10597
HS-1
10152
10549
DS-1
11871
WC-1
LAV-1
10116
21352
10549
10152
11871
WC-1
LAV-1
10116
21352
10153
10215
17565
RS-1
10597
11003
CRS-1
22642
22768
10153
13700
10804
10447
3CS-1
13588
14688
10995
10922
MS-1
FD-1
10594
FD-1
10594
HS-1
DS-1
(E) WFS-1
(E) DW-1
7
5
(E) EM-1
5
(E) EM-1
11003
CRS-1
22642
22768
10153
23443
5
OVEN
COMBI
HS-1
3
3
3
(E) EWH-1 8
4
23355BP-1
(E) WATER
SOFTENER 6
RCP-1
2
5
3DB-15
22885
(E) IM-1
(E) RO-1
9
9
BELOW
FLOOR
TP
10
TP
10
1/2"
1/2"HW 120°
CW
3/
4
"
3/
4
"
HW
1
2
0
°
CW
3/4"HW 140°
3/4"HW 120°
3/4"HWR
3/
4
"
1/2"HW 120°1/2"CW
3/4"CW
3/4"CW
1/
2
"
1/
2
"
HW
1
2
0
°
HW
R
HW
1
2
0
°
HW
R
3/
4
"
HW
1
4
0
°
HW
1
2
0
°
HW
R
3/
4
"
3/
4
"
HW
1
2
0
°
HW
R
3/
4
"
HW
1
4
0
°
1/
2
"
CF
W
3/
4
"
1-
1
/
4
"
3/
4
"
11
CW
1-
1
/
4
"
1
3
CW
1-
1
/
4
"
1"HW 120°3/4"HW 120°
CW3/4"CFW3/4"
CW1-1/4"CFW1/2"
CW1-1/4"CFW1/2"
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
Revision Schedule
Rev Date By Description
March 24
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
7
/
0
3
/
2
0
2
4
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
76085-018
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1 07/03/24 MZ 1st Round Of Comment
N
1/4" = 1'-0"1PLUMBING WATER PLAN
PLUMBING WATER
PLAN
P-100
1
PLUMBING PLAN KEY NOTES
GENERAL NOTES
ABBREVIATION LEGEND:
3CS-1 = 3-COMPARTMENT SINK
CRS-1 = COUNTERTOP RAINSE SINK
DB-1 = DUAL BREWER
DS-1 = DUMP SINK
DW-1 = DISH WASHER
EM-1 = ESPRESSO MACHINE
FD-1 = FLOOR DRAIN
FS-1 = FLOOR SINK
HS-1 = HAND SINK
IM-1 = ICE MACHINE
LAV-1 = LAVATORY
MS-1 = MOP SINK
RO-1 = REVERSE OSMOSIS WATER FILTER
RS-1 = RINSE SINK
WC-1 = WATER CLOSET
WFS-1 = WATER FILLING STATION
EWH-1 = ELECTRIC WATER HEATER
2
3
4
5
6
7
8
9
10
11
A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT
NECESSARILY SHOWN.
B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK
TO REVEAL FULL SCOPE OF WORK.
C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS
EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS.
D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS
OTHERWISE NOTED.
E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.
F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK.
G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2"
(10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO
SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS.
H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS
LISTED IN THE PROJECT MANUAL.
I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF
WATER FILTRATION SYSTEM.
J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW
TO RENOVATED SYSTEMS.
1-1/4'' CW LINE CONNECT TO (E) EXISTING WATER METER. SEE PS-100 PLUMBING SITE PLAN
FOR CONTINUATION.
3/4" CW, 3/4" CFW & 3/4" HW 120° DOWN WALL AND RUN BELOW GRADE. PROVIDE SHUT
OFF VALVES AT WALL STUBS.
PROVIDE ASSE 1070 THERMOSTATIC MIXING VALVE (TMV-2) SET AT 108° F TEMPERATURE
TO MAINTAIN.
PROVIDE ASSE 1070 THERMOSTATIC MIXING VALVE (TMV-1) SET AT 120° F TEMPERATURE
TO MAINTAIN.
PROVIDE ASSE 1012 APPROVED DUAL CHECK VALVE WITH ATMOSPHERIC VENT FOR
EXPRESSO MACHINE, ICE MACHINE, OVEN COMBI AND DUAL BREWER.
COLD WATER FROM WATER SOFTENER TO R.O. CONTROL SYSTEM AND WATER HEATER.
EXISTING DISHWASHER MODEL NO.: LXEH FROM HOBART MANUFACTURER.
RELOCATE EXISTING WATER HEATER AND PROVIDE NEW SUPPORT.
PROVIDE ASSE 1010 OR PDI-WH 201 APPROVED WATER HAMMER ARRESTOR DEVICE FOR
ALL QUICK-ACTING WATER VALVES.
1/2" CW TO TRAP PRIMER MODEL NO: TP300T FROM WATTS MANUFACTURER.
BALANCING VALVE, CHECK VALVE AND ISOLATION VALVE AT HOT WATER RETURN
CONNECTION TO HOT WATER LINE.
A
5
A
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
2301 N Tustin Ave
#A8/22/2024
RETAIL
SEATING
AREA
UNISEX
CUSTOMER
RESTROOM
UNISEX
PARTNER
RESTROOM
PARTNER /
MANAGER
AREA
BACKBAR
WORKROOM
(E) FCO
(E) FCO
11871
WC-1 LAV-1
10116
21352
DS-1
10549
10152
11871
WC-1
LAV-1
10116
21352
10153
10215
17565
RS-1
HS-1
10594
11003
CRS-1
22642
22768
10153
DS-1
10549
10152
10594
13700
10804
10447
3CS-1
HS-1
13588
14688
10995
10922
23355
MS-1
FD-1
10594
FD-1
10594
(E) WFS-1
DW-1
(E)IM-1
(E) 4'' VTR
(E) 4" SS
(E) 4" SS
(E
)
4
"
S
S
(E
)
4
"
S
S
HS-1
23443
OVEN
COMBI
5
5
(E) 3" V (E) 3" V (E) 3" V
(E
)
2
"
V
(E
)
2
"
V
(E
)
2
"
V
FCO
11003
CRS-1
22642
22768
10153
(E) EM-1
2
(E) EM-1
2 3
6
5
6
6
6
FCO
6
2% SLOPE 2% SLOPE
2% SLOPE
2
6
6
5
3" GW
3" GW
3"
G
W
(E
)
4
"
S
S
FCO
6
6
66
(E) 2" V
(E) 4" SS
2% SLOPE
4" SS
2" V
2"
V
(E)
4
"
S
S
3" GW
2% SLOPE
2"
V
5
2" V
2" V
2" V
4" SS4" SS
(E
)
4
"
S
S
2%
S
L
O
P
E
2%
S
L
O
P
E
4"
G
W
2%
S
L
O
P
E
4"
G
W
4" SS
4
1 1
2" V B.G.
2" V
(E
)
4
"
S
S
3" V B.G.
1
6
6
5
(E) EWH-1
5
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
Revision Schedule
Rev Date By Description
March 24
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
7
/
0
3
/
2
0
2
4
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
76085-018
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1 07/03/24 MZ 1st Round Of Comment
N
1/4" = 1'-0"1PLUMBING WASTE PLAN
PLUMBING WASTE
PLAN
P-200
SEE PS-100 PLUMBING PLAN FOR CONTINUATION.
INDIRECTLY DRAIN FIXTURE TO NEAREST FLOOR SINK. TERMINATE W/ 2" AIR GAP.
3" WASTE LINE FROM 3-COMPARTMENT SINK TERMINATE TO THE FLOOR SINK WITH AIR GAP
CONNECTION.
3/4" TEMPERATURE AND RELIEF DRAIN TERMINATE OUT SIDE THE BUILDING.
POINT OF CONNECTION OF NEW SANITARY SEWER PIPE TO EXISTING SANITARY SEWER
PIPE.CONTRACTOR SHALL FIELD VERIFY ALL PIPE CONDITIONS PRIOR TO CONSTRUCTION ,
INCLUDING EXACT LOCATION, AVAILABLE INVERT, DIRECTION OF FLOW, AND CAPACITY FOR
THE ADDED FIXTURE LOAD FROM THIS T.I..
POINT OF CONNECTION OF NEW VENT PIPE TO EXISTING VENT PIPE. CONTRACTOR SHALL
FIELD VERIFY ALL PIPE CONDITIONS PRIOR TO CONSTRUCTION , INCLUDING EXACT
LOCATION, AVAILABLE INVERT, DIRECTION OF FLOW, AND CAPACITY FOR THE ADDED
FIXTURE LOAD FROM THIS T.I..
3" GREASE VENT LINE UP TO ROOF AND TERMINATE ON THE ROOF WITH WEATHER
PROTECTIVE CAP.
1
PLUMBING PLAN KEY NOTES
GENERAL NOTES
2
3
4
5
6
A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT
NECESSARILY SHOWN.
B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK
TO REVEAL FULL SCOPE OF WORK.
C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS
EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS.
D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS
OTHERWISE NOTED.
E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.
F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK.
G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2"
(10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO
SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS.
H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS
LISTED IN THE PROJECT MANUAL.
I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF
WATER FILTRATION SYSTEM.
J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW
TO RENOVATED SYSTEMS.
7
ABBREVIATION LEGEND:
3CS-1 = 3-COMPARTMENT SINK
CRS-1 = COUNTERTOP RAINSE SINK
DB-1 = DUAL BREWER
DS-1 = DUMP SINK
DW-1 = DISH WASHER
EM-1 = ESPRESSO MACHINE
FD-1 = FLOOR DRAIN
FS-1 = FLOOR SINK
HS-1 = HAND SINK
IM-1 = ICE MACHINE
LAV-1 = LAVATORY
MS-1 = MOP SINK
RO-1 = REVERSE OSMOSIS WATER FILTER
RS-1 = RINSE SINK
WC-1 = WATER CLOSET
WFS-1 = WATER FILLING STATION
EWH-1 = ELECTRIC WATER HEATER
A
5
A
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
2301 N Tustin Ave
#A8/22/2024
WC-1-1x3/4"
(2.5)
LAV-1-2x1/2"
(1)
DS-1-2x1/2"
(1.5)
WC-1-1x3/4"
(2.5)
LAV-1-2x1/2"
(1)
3CS-1-2x3/4"
(3)(E) DW-1-1x3/4"
(1.5)
(E) WFS-1-3x1/2"
(1.5)
HS-1-2x1/2"
(1.5)DS-1-2x1/2"
(1.5)
(E) IM -1-1X1/2''
(0.5)
DB-1-1x1/2"
(0.5)
HS-1-2x1/2"
(1.5)
MS-1-2x3/4"
(3)
(E) RO-1
(E) WATER
SOFTENER
BP-1
(E) EM-1-1x1/2"
(0.5)
(E) EM-1-1x1/2"
(0.5)
CRS-1-3x1/2"
(1.5)
CRS-1-3x1/2"
(1.5)
RS-1-3x1/2"
(1.5)
OVEN COMBI
2x1/2" (0.5)
HS-1-2x1/2"
(1.5)
TMV-1
2
TMV-1
2
RCP-1
3/4" CW
(2.5)
3/4" CW
(2.5)
1/2" CW
(1)
1/2" HW120°1/2" CW
(1)
1/2" HW120°
1/2" CW
(1.5)
1/2" HW120°
3/4" CW
(3)
3/4" HW140°
3/4" HW140°
1/2" CW
(1.5)
1/2" HW120°
1/2" HW120°
1/2" CW
(1.5)
1/2" CW
(1.5)
1/2" HW120°
3/4" CW
(3)
3/4" HW140°
1/2" CW
(1.5)
1/2" HW120°
1/2" CFW
3/4" CW B.G.
(4)
3/4" HW120° B.G.
3/4" CFW B.G.
1/2" HW120°
1/2" CW
(1.5)
1/2" CW
(0.5)
(E) EWH-1
1-1/4" CW
(25.5)
1/2" HW120°
1-1/4" CW
(14.5)
3/4" HW120°
3/4" CW
(7.5)
3/4" HW120°
3/4" HW140°
1-1/4" CW
(12.5)
3/4" HW140°
1/2" CFW
3/4" HWR
3/4" HWR
1" HW120°
1-1/4" CW
(14)
3/4" HW140°
3/4" CW
(10.5)
1-1/4" CW
(22)
3/4" HW120°
3/4" HWR
3/4" CW
(3.5)
1/2" HW120°
TMV-1
2
TMV-1
2
TMV-1
2
1/2" CFW
DUAL CHECK
VALVE
DUAL CHECK
VALVE
1/2" HW120°
3/4" CFW
TMV-2
3
3
1/2" CFW
3/4" HWR
1-1/4" CW
(16)
3/4" HW120°
3/4" HW140°
1/2" CFW
3/4" HWR
1-1/4" CW
(17.5)
3/4" HW120°
3/4" HWR
1
DUAL CHECK
VALVE
DUAL CHECK
VALVE
DUAL CHECK
VALVE
3/4" CW
(1.5)
1/2" HW120°
1-1/4" CW
(30.5)
1-1/4" CW
(27)
1/2" HW120°
3/4" HWR
1/2" CFW
1/2" CFW
4
5
1-1/4" CW
(30.5)
3/4" CW
(1.5)
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
Revision Schedule
Rev Date By Description
March 24
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
7
/
0
3
/
2
0
2
4
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
76085-018
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1 07/03/24 MZ 1st Round Of Comment
1PLUMBING WATER ISOMETRIC
PLUMBING WATER
ISOMETRIC
P-400
GENERAL NOTES
NTS
PROVIDE ASSE 1070 THERMOSTATIC MIXING VALVE (TMV-2) SET AT 120° F TEMPERATURE
TO MAINTAIN.
PROVIDE ASSE 1070 THERMOSTATIC MIXING VALVE (TMV-1) SET AT 108° F TEMPERATURE
TO MAINTAIN.
PROVIDE ASSE 1010 OR PDI-WH 201 APPROVED WATER HAMMER ARRESTOR DEVICE FOR
ALL QUICK-ACTING WATER VALVES.
BALANCING VALVE, CHECK VALVE AND ISOLATION VALVE AT HOT WATER RETURN
CONNECTION TO HOT WATER LINE.
1-1/4'' CW LINE CONNECT TO (E) EXISTING WATER METER. SEE PS-100 PLUMBING SITE PLAN
FOR CONTINUATION.
1
PLUMBING PLAN KEY NOTES
A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT
NECESSARILY SHOWN.
B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK
TO REVEAL FULL SCOPE OF WORK.
C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS
EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS.
D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS
OTHERWISE NOTED.
E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.
F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK.
G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2"
(10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO
SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS.
H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS
LISTED IN THE PROJECT MANUAL.
I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF
WATER FILTRATION SYSTEM.
J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW
TO RENOVATED SYSTEMS.
2
3
4
ABBREVIATION LEGEND:
3CS-1 = 3-COMPARTMENT SINK
CRS-1 = COUNTERTOP RAINSE SINK
DB-1 = DUAL BREWER
DS-1 = DUMP SINK
DW-1 = DISH WASHER
EM-1 = ESPRESSO MACHINE
FD-1 = FLOOR DRAIN
FS-1 = FLOOR SINK
HS-1 = HAND SINK
IM-1 = ICE MACHINE
LAV-1 = LAVATORY
MS-1 = MOP SINK
RO-1 = REVERSE OSMOSIS WATER FILTER
RS-1 = RINSE SINK
WC-1 = WATER CLOSET
WFS-1 = WATER FILLING STATION
EWH-1 = ELECTRIC WATER HEATER
5
5
A
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
2301 N Tustin Ave
#A8/22/2024
FCO
(E) FCO
HS(2)
WCO
DW
FS
(E) WFS(2)
FS
3CS(6)
HS(2)
WCO
MS(3)
HS(2)
FS
CRS(2)
FS
CRS(2)
LAV-1(1)
LAV-1(1)
FS
IM(2)
FS
DS(2)
FS
RS(2)
FD(2)
FD(2)
WC(4)
WC(4)
(E) 4"VTR
(E) 4"SS
(8)
(E) 4"SS
(8)
(E) 4"SS
(6)
(E) 4"SS
(4)
(E) 4"SS
(2)
(E) 4"SS
(17)
(E) 4"SS
(24)
FS
OVEN
COMBI (2)
2"GW
(2)
3"GW
(4)
3"GW
(6)
3"GW
(11)
3"GW
(13)3"GW
(13)
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
DS(2)
4"GW
(19)
4"GW
(21)
(E) 3"V
(E) 3"V
(E) 3"V
(E) 3"V
(E) 3"V
(E) 2"V
(E) 2"V
(E) 2"V
(E) 2"V
(E) 2"V
2% S
L
O
P
E
2% S
L
O
P
E
2% S
L
O
P
E
2% S
L
O
P
E
2% S
L
O
P
E
(E) 2"V
1
WCO
WCO
WCO
2"GW
(2)
2"GW
(3)
2"GW
(2)
3"GW
(6)
2"GW
(2)
2"V
2"V
2"SS
(2)
2"V
4"SS
(7)
2"SS
(1)
4"SS (7)
4"SS (4)
(E) 2"V
(E) 2"V
2"V
2"V
2"V
2"V
2"V
2"V
2"V
2"V
2"V
(E) 4"SS
(10)
(E) 4"SS
(10)
3"GW
(13)
2% S
L
O
P
E
2% S
L
O
P
E
2% S
L
O
P
E
2% S
L
O
P
E
2"V
FCO
(E) FCO
WCO
FCO
(E) 4"SS
(4)
2"GW
(2)
2"GW
(2)
WCO
2"SS
(1)
2"SS
(3)
3" VTR
2
3
2" V B.G.
2" V B.G.
3
3
3
3
3
3
3
3
3
3
3
3
2
2
2
2
2
2
2% S
L
O
P
E
(E) 4"SS
(2)
2"V
2"V
2"V
2"V
2"V
2"V
2"V
2"V
2"V
2"V
2"V
2"V
2"V
2"V
2"V
2"V
SAMPLE BOX
SV-10
3"GW
(19)
WCO
1
GB-75 GREASE
INTERCEPTOR
GI-1
3" VTR
3" V B.G.
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
Revision Schedule
Rev Date By Description
March 24
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
-
0
7
/
0
3
/
2
0
2
4
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
76085-018
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1 07/03/24 MZ 1st Round Of Comment
1PLUMBING WASTE & VENT ISOMETRIC
PLUMBING WASTE &
VENT ISOMETRIC
P-401
GENERAL NOTES
NTS
CONTRACTOR SHALL FIELD VERIFY ALL PIPE CONDITIONS PRIOR TO CONSTRUCTION ,
INCLUDING EXACT LOCATION, AVAILABLE INVERT, DIRECTION OF FLOW, AND CAPACITY FOR THE
ADDED FIXTURE LOAD FROM THIS T.I..
POINT OF CONNECTION OF NEW SANITARY SEWER PIPE TO EXISTING SANITARY SEWER
PIPE.CONTRACTOR SHALL FIELD VERIFY ALL PIPE CONDITIONS PRIOR TO CONSTRUCTION ,
INCLUDING EXACT LOCATION, AVAILABLE INVERT, DIRECTION OF FLOW, AND CAPACITY FOR THE
ADDED FIXTURE LOAD FROM THIS T.I..
POINT OF CONNECTION OF NEW VENT PIPE TO EXISTING VENT PIPE. CONTRACTOR SHALL FIELD
VERIFY ALL PIPE CONDITIONS PRIOR TO CONSTRUCTION,INCLUDING EXACT LOCATION,
AVAILABLE INVERT, DIRECTION OF FLOW, AND CAPACITY FOR THE ADDED FIXTURE LOAD FROM
THIS T.I..
2
PLUMBING PLAN KEY NOTES
3
A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT
NECESSARILY SHOWN.
B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK
TO REVEAL FULL SCOPE OF WORK.
C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS
EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS.
D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS
OTHERWISE NOTED.
E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.
F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK.
G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2"
(10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO
SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS.
H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS
LISTED IN THE PROJECT MANUAL.
I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF
WATER FILTRATION SYSTEM.
J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW
TO RENOVATED SYSTEMS.
1
ABBREVIATION LEGEND:
3CS-1 = 3-COMPARTMENT SINK
CRS-1 = COUNTERTOP RAINSE SINK
DB-1 = DUAL BREWER
DS-1 = DUMP SINK
DW-1 = DISH WASHER
EM-1 = ESPRESSO MACHINE
FD-1 = FLOOR DRAIN
FS-1 = FLOOR SINK
HS-1 = HAND SINK
IM-1 = ICE MACHINE
LAV-1 = LAVATORY
MS-1 = MOP SINK
RO-1 = REVERSE OSMOSIS WATER FILTER
RS-1 = RINSE SINK
WC-1 = WATER CLOSET
WFS-1 = WATER FILLING STATION
EWH-1 = ELECTRIC WATER HEATER
5
A
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
0
7
/
0
2
/
2
0
2
4
2301 N Tustin Ave
#A8/22/2024
CONFIGURATION III
WATER FILTRATION
SYSTEM. SEE
CONFIGURATION III, R.O.
AND SOFTENER DETAIL
FOR MORE
INFORMATION.
R.O. PERMEATE
TANK
FRP ENCLOSED
6"
(
1
8
3
0
M
M
)
M
I
N
.
CL
E
A
R
4'
-
2
"
(
1
2
7
0
M
M
)
BA
C
K
E
R
2'
-
6
"
(
7
6
5
M
M
)
7'
-
2
"
(
2
1
8
5
M
M
)
NOTE :
1. KEEP CLEAR AT BACKWALL FOR CHEMICAL DISPENSING SYSTEM COMPONENTS, TO BE INSTALLED BY SYSTEM VENDOR. REFER TO
POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION
2'
-
0
"
(
6
1
0
M
M
)
OPEN CEILING ABOVE
WATER HEATER PER
LOCAL CODE
STRAP UNITS PER LOCAL
CODE REQUIREMENTS
PROVIDE MOISTURE-
RESISTANT BLOCKING TO
STRUCTURE BEHIND
WALL FINISH AT THESE
AREAS. REFER TO ITEM
SPECIFICATIONS FOR
PLUMBING SCOPE;
COORDINATE INSTALL
WITH FILTER VENDOR.
FRP ENCLOSED
HOT WATER TANK. SEE
SPECIFICATIONS AND
WATER HEATER TANK
DETAIL FOR MORE
INFORMATION.
MOP HOLDER
3'
-
0
"
(
9
1
5
M
M
)
5'
-
0
"
(
1
5
2
5
M
M
)
HOSE CLIP
HOT AND COLD
WATER SUPPLY
FOR FAUCET
MOP SINK
SEE NOTE 1
BELOW
SEE NOTE 1
BELOW
2'-0"(610MM)
6'-0"(1830MM) MIN.
BLENDED STORAGE
TANK ON WALL
MOUNTED SHELF
WATER BOOSTER PUMP
SEE BOOSTER PUMP
DETAIL FOR MORE
INFORMATION.
FRP ENCLOSED
9'
-
6
"
(
2
8
9
5
M
M
)
T
O
B
O
T
T
O
M
O
F
B
L
E
N
D
E
D
S
T
O
R
A
G
E
T
A
N
K
S
H
E
L
F
HOT WATER TANK (SEE
SPECIFICATIONS & HOT WATER
TANK DETAIL FOR FURTHER
INSTALLATION REQUIREMENTS)
1" (25MM)
BRASS CHECK
VALVE
EXPANSION TANK
STRAP UNITS PER LOCAL
REQUIREMENTS
HOT WATER TO DISHWASHER
(IF OTHER THAN HOBART
ADVANSYS UNIT), BAR SINKS,
MOP SINK AND COMPARTMENT
SINK.
1" (25MM) HOT WATER OUTLET
TEMPERED HOT WATER TO
HAND SINKS
TEMPERATURE MIXING
VALVES
UNION (TYP.)CONCEALED
COPPER PIPING (TYP.)
IF CONFIGURATION II
OR III, SOFTENED
COLD WATER TO
DISHWASHER
(IF HOBART
ADVANSYS UNIT).
SEE NOTE 2 BELOW.
OPEN CEILING ABOVE
WATER HEATER PER
LOCAL CODE
PAN AND DRAIN LINE FOR
MAINTENANCE
BOOSTER PUMP.
SEE BOOSTER PUMP
DETAIL FOR MORE
INFORMATION.
FL
O
W
DI
R
E
C
T
I
O
N
NOTES :
1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY.
2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND ADVANSYS
DISHWASHER WHERE ALLOWED BY CODE.
3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES.
4.. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED..
FLOW
DIRECTION
3/4" (20MM)
CHROME ESCUTCHEONS (TYP.)
3/4" (20MM)
BRASS THREADED BALL SHUT-OFF VALVE
(TYP.) MAX 72" (1830MM) A.F.F.
UNION (TYP.)
3/4" (20MM)
FILTERED COLD WATER
TO ICE MACHINE
POINT OF USE
FILTER LOCATED AT
ICE MACHINE
MOP SINK
NOTES:
1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. GC TO COORDINATE INSTALLATION OF ALL OTHER COMPONENTS SHOWN WITH FILTER VENDOR.
2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND FROM SOFTNER TO ADVANSYS DISHWASHER WHERE ALLOWED BY CODE.
3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES.
4. PROVIDE WATER SOFTENER INDIRECT DRAIN TO SINK, INSTALLED PER CODE. (CONFIRM REQUIREMENTS WITH SOFTENER EQUIPMENT CUTSHEETS IN ITEM SPECIFICATIONS).
5. IN MUNICIPALITIES WITH BRINE RESTRICTIONS, REFER TO THE WATER SYSTEM CONFIGURATIONS APPENDIX UNDER ITEM SPECIFICATIONS FOR WATER SOFTENER EXCHANGE TANK SCHEMATIC.
6. COMPONENTS ARE TO BE POSITIONED TO MAXIMIZE ACCESS FOR REGULAR SERVICING. PRE-FILTER, BYPASS VALVES, AND SOFTENER TANKS MUST BE INSTALLED 72" (1828MM) AFF OR LOWER.
R.O. PERMEATE
TANK
7"(75MM)
(180MM)
9 1/4"(75MM)
(235MM)
GFCI 120V QUAD
RECEPTACLE FOR
FILTER SYSTEM 77"
(1955MM) A.F.F.
(SEE NOTE 3)FILTERED COLD WATER
TO FIXTURES (ESPRESSO
MACHINES, BREWERS,
HOT TAP, WATER TOWER
FAUCET)
75
"
(
7
9
0
5
M
M
)
OUT
R.O. CONTROL SYSTEM
(SEE NOTE 5)
3/4" (20MM)
SHUT-OFF
VALVE
3/4" (15MM)
FIP
3/4" (20MM) SHUT-OFF VALVE
3/4" (20MM) BYPASS
3/4" (20MM) SHUT-OFF
VALVE
CITY WATER IN
TO NON FILTERED
FIXTURES (TOILETS,
HAND SINKS, DIPPER
WELLS, BLENDER
PITCHER RINSERS,
IN-COUNTER RINSERS,
BAR SINKS, HOSE BIBBS)
3/4" (20MM) FIP
(FEMALE
INTERNATIONAL
PIPE THREAD
FITTING) (TYP. 1 OF
2 TO SOFTENER)
GFCI 120V
RECEPTACLE FOR
FILTER SYSTEM AT
54" (1372MM) A.F.F.
(SEE NOTE 3)
IN
DIE EXCHANGE SYSTEM
(EXISTING)
WATER SOFTENER
HEAD AND TANKS
(BEHIND)
DRAIN LINE FROM
WATER HEATER
TANK PAN ABOVE
11"(75MM)
255MM)
3"(75MM)
WATER
HEATER TANK
SEE WATER
HEATER TANK
DETAIL FOR
MORE
INORMATION
FROM WATER
HEATER TANK
TEMPERING
VALVE
OUT
IN IN
TO HOT WATER TANK
AND ADVANSYS
DISHWASHER
PLUMBING. SEE
WATER HEATER TANK
DETAIL FOR MORE
INORMATION
BYPASS VALVE
BLENDED STORAGE
TANK ON WALL
MOUNTED SHELF
5'
-
0
"
(
7
5
M
M
)
TO R.O. SYSTEM
BOOSTER
PUMP
BYPASS
VALVE
3/4" (20MM)
CITY
WATER
IN
BOOSTER
PUMP
SHUT-OFF
VALVE
TO
BOOSTER
PUMP
3/4" (20MM)
BOOSTED
WATER IN
5'
-
9
"
(
7
5
M
M
)
WATER FILTRATION
BOOSTER PUMP.
SEE BOOSTER
PUMP DETAIL
FOR MORE
INFORMATION
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
Revision Schedule
Rev Date By Description
March 24
CH
E
C
K
S
E
T
-
0
3
/
2
2
/
2
0
2
4
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
76085-018
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
1/2" = 1'-0"2CONFIGURATION III
3/4" = 1'-0"3WATER HEATER TANK - PLUMBING
1" = 1'-0"1CONFIGURATION III, R.O. AND SOFTENER WATER FILTRATION
PLUMBING DETAILS
P-500
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
5
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
1' - 2"
SEE PLUMBING
PLAN FOR FINAL
FLOOR SINK
LOCATION AND
TYPE
ICE BIN
ABOVE
INDIRECT DRAIN LINE
FROM ESPRESSO
MACHINE TO FLOOR
SINK
UNDERCOUNTER
REFRIGERATOR
INDIRECT DRAIN
LINE FROM
RINSER SINK TO
FLOOR SINK
UNDERCOUNTER
CABINET
INDIRECT AND
INSULATED DRAIN LINE
FROM ICE BIN ABOVE
TO FLOOR SINK
SUPPORT
LEG (TYP.)
2'
-
6
1
/
2
"
UNDER COUNTER
UNDERCOUNTER
REFRIGERATOR
NON-FILTERED COLD
WATER SUPPLY FOR
METERED SPOON RINSER
NON-FILTERED COLD
WATER SUPPLY FOR
PITCHER RINSER
ICE BIN
RINSER SINK
UNDERCOUNTER
CABINET
ABOVE COUNTER
5' - 9"
UNDERCOUNTER
BOILER FOR INSTANT
HOT WATER FONT
FILTERED COLD
WATER SUPPLY
FOR ESPRESSO
MACHINE
FILTERED COLD WATER
SUPPLY FOR WATER
TOWER DISPENSER
FILTERED COLD WATER
SUPPLY FOR INSTANT
HOT/COLD WATER FONT
*
FILTERED COLD WATER
SUPPLY FOR INSTANT
HOT/COLD WATER BOILER
*
*
**
PROVIDE WATER HAMMER ARRESTOR PRIOR TO
SHUT-OFF VALVE AND FLEX HOSE CONNECTION*
**PROVIDE BACKFLOW PREVENTION DEVICE
BEFORE PUMP AND WATER HAMMER ARRESTOR
PRIOR TO SHUT-OFF VALVE AND FLEX HOSE
CONT. INDIRECT AND
INSULATED DRAIN LINE
FROM ICE BIN AT SECOND
ESPRESSO BAR TO
FLOOR SINK HERE
CONT. INDIRECT DRAIN LINE
FROM ESPRESSO MACHINE
AT SECOND ESPRESSO BAR
TO FLOOR SINK HERE
HOT AND COLD WATER
FOR SINK FAUCET AT 20
1/2" (520MM) A.F.F. SHUT-
OFF VALVES AT WALL
AND 4" (100MM) EITHER
SIDE OF WASTE LINE.FILTERED
COLD WATER
SUPPLY FOR
BREWER WITH
SHUT-OFF IN
CABINET AT
24" (610MM)
A.F.F.
9'-3 1/2"
*
PROVIDE BACKFLOW PREVENTION DEVICE THEN
WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF
VALVE AND FLEX HOSE CONNECTION
*
10"
FLOOR SINK
2'
-
5
1
/
2
"
FL
O
O
R
S
I
N
K
SEE PLUMBING PLAN FOR FINAL
FLOOR SINK LOCATION AND TYPE
INDIRECT DRAIN LINE FROM
RINSE SINK TO FLOOR SINK
INDIRECT
DRAIN LINE
FROM
BREWER TO
FLOOR SINK
DIRECT DRAIN LINE FROM
SINK. ROUGH-IN SINK
WASTE STUB AT 15 1/2"
(394MM) A.F.F. AND
CENTERLINE OF SINK
TEMPERED HOT AND COLD
WATER FOR SINK FAUCET
AT 20 1/2" (520MM) A.F.F.
SHUT-OFF VALVES AT WALL
AND 4" (102MM) EITHER
SIDE OF WASTE LINE.
1'-3"
EQ EQ
ELEVATION - PLUMBING DIAGRAM FLOOR SINK
COLD WATER SUPPLY
FOR COMBI OVEN
CLEANING WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
FILTERED WATER
SUPPLY FOR COMBI
OVEN WATER
INJECTION WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
PLAN - PLUMBING DIAGRAM
6'-6"
FILTERED WATER
SUPPLY FOR COMBI
OVEN WATER INJECTION
WITH SHUT-OFF IN
CABINET AT 18" (457MM)
A.F.F.
COLD WATER SUPPLY
FOR COMBI OVEN
CLEANING WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
INDIRECT DRAIN LINE
FROM COMBI OVEN TO
FLOOR SINK
SEE PLUMBING PLAN
FOR FINAL FLOOR SINK
LOCATION AND TYPE
ICE BIN
(TYP. 1 OF 2)NON-FILTERED COLD
WATER SUPPLY FOR
METERED SPOON
RINSER (TYP. 1 OF 2)
NON-FILTERED COLD
WATER SUPPLY FOR
PITCHER RINSER
(TYP. 1 OF 2)
RINSER SINK
(TYP. 1 OF 2)
UNDERCOUNTER REFRIGERATOR (TYP. 1 OF 2)
2'
-
6
1
/
2
"
6'-0"4'-9 1/2"
UNDERCOUNTER
BOILER FOR
INSTANT HOT
WATER FONT
(TYP 1 OF 2)
INDIRECT DRAIN
LINE FROM
RINSER SINK TO
FLOOR SINK
(TYP.)
INDIRECT DRAIN
LINE FROM
ESPRESSO
MACHINE TO
FLOOR SINK (TYP.)
ICE BIN ABOVE WITH
INDIRECT AND
INSULATED DRAIN
LINE TO FLOOR SINK
BELOW
UNDERCOUNTER
REFRIGERATOR (TYP. 1 OF 2)
COUNTERTOP
ABOVE
FLOOR SINK (TYP. 1 OF 2)
SEE PLUMBING PLAN
FOR FINAL LOCATIONS
AND TYPE
CABINETRY FRAME
(TYP.)
CABINETRY LEG
(TYP.)
INDIRECT DRAIN
LINE FROM RINSER
SINK TO FLOOR
SINK (TYP.)
INDIRECT DRAIN LINE FROM
ESPRESSO MACHINE TO
FLOOR SINK
FILTERED COLD WATER
SUPPLY FOR INSTANT
HOT/COLD WATER FONT
(TYP. 1 OF 2)
*
FILTERED COLD
WATER SUPPLY FOR
UNDERCOUNTER
INSTANT HOT
WATER BOILER
(TYP. 1 OF 2)
*
FILTERED COLD WATER
SUPPLY FOR WATER
TOWER DISPENSER
(TYP. 1 OF 2)
*
UNDER COUNTER
ABOVE COUNTER
FILTERED COLD
WATER SUPPLY FOR
ESPRESSO MACHINES
(TYP. 1 OF 2)
**
PROVIDE WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE CONNECTION*
**PROVIDE BACKFLOW PREVENTION DEVICE BEFORE PUMP AND WATER HAMMER ARRESTOR
PRIOR TO SHUT-OFF VALVE AND FLEX HOSE
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
Revision Schedule
Rev Date By Description
March 24
CH
E
C
K
S
E
T
-
0
3
/
2
2
/
2
0
2
4
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
76085-018
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
3/4" = 1'-0"4ESP 10-02 PLUMBING
3/4" = 1'-0"5DTE 06-03 PLUMBING
3/4" = 1'-0"1BRW 09-01 PLUMBING 3/4" = 1'-0"3ADD-ON HAND SINK PLUMBING
3/4" = 1'-0"2AC WRM-20 PLUMBING
PLUMBING DETAILS
P-501
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
5
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
INDIRECT DRAIN
LINE FROM ICE
MACHINE TO FLOOR
SINK
SEE PLUMBING
PLAN FOR FINAL
FLOOR SINK
LOCATION AND
TYPE
.6" (152MM) MIN.
CLEAR TO BACK
WALL
INDIRECT DRAIN
LINE FROM ICE BIN
TO FLOOR SINK
INDIRECT DRAIN
LINE FROM ICE
DIVERTER TO
FLOOR SINK
ICE MACHINE
ICE TRANSPORT
TUBE BETWEEN ICE
MACHINE AND
DIVERTER VALVE.
MAX. LENGTH 10'
(3M)
ICE HEAD ADAPTER
ICE MANAGER
CONTROL PANEL
ICE TRANSPORT
TUBE LANE 2, TO
ICE BIN. MAX
LENGTH 75', MIN.
SLOPE 1/4":1'
ICE TRANSPORT
TUBE LANE 1, TO
ICE DISPENSER.
MAX LENGTH 75',
MIN. SLOPE 1/4":1'
3" PVC SLEEVE TO
SUPPORT ICE
TRANSPORT
TUBEFASTENED TO
WALL OR CEILING
W/ STRAPING @ 48"
O.C. MIN.
ICE DIVERTER
VALVE
ELEVATION - PLUMBING DIAGRAM
PLAN - PLUMBING DIAGRAM
CONT. FRP TO
CEILING ON BACK
WALL OVER IN
WALL BLOCKING
ICE BIN
ICE MACHINE
ICE HEAD ADAPTER
NOTE:
INDIRECT DRAIN MIN. RADIUS = 8"
ICE TRANSPORT TUB MIN. RADIUS = 6"
NOTE:
INDIRECT DRAIN MIN. RADIUS = 8"
ICE TRANSPORT TUB MIN. RADIUS = 6"
ECO-GRIP COVER
BASE
ACCESSIBLE
CLEARANCE AT
CONTROL PANEL
ICE MANAGER
CONTROL PANEL
ICE DIVERTER
VALVE
CONT. FRP ON
BACK WALL OVER
IN WALL BLOCKING
BACK WALL
MIN.
r 6"
BIN TOP SENSOR
DISTRIBUTION UNIT
ICE BIN
INDIRECT DRAIN
LINE FROM ICE
MACHINE TO FLOOR
SINK
4' - 0"
2'
-
6
"
Plan View
KEEP CLEAR FOR WALL MOUNTED CHEMICAL
DISPENSING SYSTEM, TO BE INSTALLED BY SYSTEM
VENDOR. PROVIDE BACKING BEHIND WALL FINISH
FOR EQUIPMENT MOUNTING. REFER TO POSTED
INSTALLATION GUIDELINES FOR MORE INFORMATION.
Elevation View
SOFTENED HOT AND NON-FILTERED
COLD WATER FOR SINK FAUCET
INDIRECT DRAIN LINE FROM
DISHWASHER TO NEAREST
FLOOR SINK.
BACK WALLDRAIN LINE FROM SINK TO WASTE
LINE IN WALL OR TO FLOOR SINK
SEE PLUMBING PLAN FOR
FINAL FLOOR SINK LOCATION.
FLOOR SINK OPTIONAL.
WIRE RACK
COMPARTMENT
SINK
DISHWASHER
NOTE:
FOR COORDINATION ONLY. SEE
FURNITURE, FIXTURES, AND
EQUIPMENT PLAN FOR
EQUIPMENT LOCATIONS.
PROVIDE BACKING BEHIND WALL
FINISH AS REQUIRED FOR WALL
MOUNTED EQUIPMENT. REFER
TO ITEM SPECIFICATIONS FOR
MORE INFORMATION.
PRE-WASH STATION
4'
-
0
"
(1
2
2
0
M
M
)
1'
-
2
"
(3
5
5
M
M
)
4'
-
6
"
(1
3
7
0
M
M
)
DRAIN LINE FROM DISHWARE
DRYING RACKS TO SINK BOWL
DISHWARE DRYING RACKS
WITH DRAIN LINE TO SINK BOWL
ALIGN
3'
-
1
1
"
(1
1
9
5
M
M
)
3'
-
2
"
(9
6
5
M
M
)
11'-4"(3455MM)
3/4" PLYWOOD BACKER BOARD
BEHIND WALL FINISH. FASTEN
TO STRUCTURE BEYOND.
3 1/4"
(80MM)
WATER FOR DISHWASHER WITH
SHUT-OFF UNDER SINK AT 18"
(460MM) AFF. LINE LENGTH MUST
ALLOW EASE OF MOVEMENT.
VERIFY WATER REQUIREMENTS
FOR TYPE OF DISHWASHER
(HOT/COLD/SOFTENED). SEE
WATER SUPPLY DRAWINGS FOR
WATER LINE. IF ADVANSYS
DISHWASHER, INCLUDE
PRESSURE REDUCING VALVE.
PRESSURE GAUGE (SET TO 20
PSIG +/- 5 PSI), LINE STRAINER
AND SHOCK ARRESTOR.
B
MOP SINK AND WATER
FILTRATION EQUIPMENT.
SEE PLAN FOR ACTUAL
CONFIGURATION.
HOT WATER TANK SUPPORT
PLATFORM PER ENGINEER'S
DRAWINGS
WATER HEATER TANK PER PLAN
HOT WATER TANK CHASE TO
STRUCTURE OR HARD LID
ABOVE. PAINT INTERIOR GWB
FINISH TO MATCH BOH FRP.
ROOF STRUCTURE PER PLAN
2'-8"
CLEAR
7'
-
2
"
BOTTOM OF WORKROOM
CEILING IN FOREGROUND
OPEN TO
WORKROOM
A
SECTION A
HOT WATER PIPING AND FLUE.
ENSURE ALL PENETRATIONS
THROUGH SURROUNDING
WALLS AND CEILING ARE
COMPLETELY SEALED.
BO
H
C
E
I
L
I
N
G
H
E
I
G
H
T
P
E
R
P
L
A
N
2"
BOOSTER PUMP
EXTEND BULKHEAD AND BACK
SURROUNDING WALLS TO
STRUCTURE ABOVE
SECTION B
ENSURE WATER TANK CHASE
IS FULLY SEALED FOR PEST
EXCLUSION
2'-8"
CLEAR
7'
-
2
"
BO
H
C
E
I
L
I
N
G
H
E
I
G
H
T
P
E
R
P
L
A
N
2"
SECTION B
7'
-
0
"
PROVIDE HARD
LID AT 7'-0"
(2135MM) ABOVE
TOP OF WATER
HEATER TANK
CHASE
HOT WATER
PIPING AND FLUE.
ENSURE ALL
PENETRATIONS
THROUGH
SURROUNDING
WALLS AND
CEILING ARE
COMPLETELY
SEALED.
ROOF
STRUCTURE
PER PLAN
PAINT CHASE INTERIOR
GWB FINISH TO MATCH
BOH FRP.
WATER
HEATER TANK
PER PLAN
HOT WATER
TANK SUPPORT
PLATFORM PER
ENGINEER'S
DRAWINGS
MOP SINK AND
WATER FILTRATION
EQUIPMENT. SEE
PLAN FOR ACTUAL
CONFIGURATION.
ENSURE
WATER TANK
CHASE IS
FULLY SEALED
FOR PEST
EXCLUSION
(ALTERNATE FOR TALL CEILING CONDITIONS)
FILTERED COLD WATER
SUPPLY FOR WATER
TOWER FAUCET *
FILTERED
COLD WATER
SUPPLY FOR
INSTANT
HOT/COLD
WATER FONT
NON-FILTERED
HOT AND COLD
WATER SUPPLY
FOR SINK
FAUCET
ABOVE COUNTERTOP
AT FLOOR LEVEL
INDIRECT LINE
FROM PREP
SINK ABOVE TO
FLOOR SINK
SHELVING
ABOVE
FILTERED COLD
WATER SUPPLY FOR
UNDERCOUNTER
INSTANT HOT
WATER BOILER
(LOCATION MAY
VARY)
**
PROVIDE WATER HAMMER ARRESTOR PRIOR TO
SHUT-OFF VALVE AND FLEX HOSE CONNECTION*
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
Revision Schedule
Rev Date By Description
March 24
CH
E
C
K
S
E
T
-
0
3
/
2
2
/
2
0
2
4
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
76085-018
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
3/4" = 1'-0"1PLUMBING - NUGGET ICE - PEDESTAL STACK
3/4" = 1'-0"2SANITIZING (GENERIC) - PLUMBING
3/8" = 1'-0"3WATER HEATER TANK CHASE 3/4" = 1'-0"4WATER FILLING STATION - PLUMBING
PLUMBING DETAILS
P-502
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
5
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
3' - 3" (915MM)
8'
-
9
"
(
2
6
7
0
M
M
)
A.
F
.
F
.
NOTES :
1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY.
2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND ADVANSYS
DISHWASHER WHERE ALLOWED BY CODE.
3. POSITION BOOSTER PUMP SO THAT PRESSURE GAUGE IS READABLE AND ACCESSIBLE FOR TROUBLESHOOTING AND MAINTENANCE.
4. BOOSTER PUMP STATIC AND DYNAMIC OUTLET PRESSURE SHALL BE BETWEEN 65 TO 70 PSI. VERIFY PER PUMPS INTEGRAL PRESSURE GAUGE.
5. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES.
6. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED.
7. PROVIDE VIBRATION DAMPENING AT BOOSTER PUMP MOUNT TO PLATFORM.
WATER
HEATER TANK.
SEE WATER
HEATER TANK
DETAIL FOR
MORE
INFORMATION.
GFCI 120V
RECEPTACLE
FOR BOOSTER
PUMP
MIN. CLEAR
2" (50MM)CITY
WATER IN
OUT TO
WATER
FILTRATION
SYSTEM
BOOSTER PUMP.
SECURE TO
SHELF BELOW
WITH BOLTS
THROUGH BASE
PLATE
SHELF PER
ENGINEER'S
DRAWINGS
(3
0
5
M
M
)
1'
-
0
"
(6
1
0
M
M
)
2'
-
0
"
(6
1
0
M
M
)
2'
-
0
"
(1
7
8
0
M
M
)
5'
-
7
1
/
2
"
MOP SINK
HOT AND
COLD WATER
SUPPLY FOR
MOP FAUCET
HOSE CLIP
WIRE RACK
STRAP UNITS PER
LOCAL CODE
REQUIREMENTS
MOP HOLDER
FRP ENCLOSED
CHEMICAL
DISPENSING SYSTEM
COMPONENTS, TO
BE INSTALLED BY
SYSTEM VENDOR.
REFER TO POSTED
INSTALLATION
GUIDELINES FOR
MORE INFORMATION.
PAN AND DRAIN
FOR MAINTENANCE
WATER HEATER
TANK
WATER HEATER
TANK PLATFORM
CEILING
IN-WALL CONTINUOUS
CONDUIT FASTENED W/
STRAPING @ 48" O.C. MIN.
ICE TRANSPORT
TUBE LANE 1, TO
ICE DISPENSER.
MAX LENGTH 75',
MIN. SLOPE 1/4":1'
1'
-
1
"
4'
-
8
1
/
2
"
OUTLET BOX FOR
INDIRECT DRAIN
LINE
FLOOR SINK
OUTLET BOX FOR
INDIRECT DRAIN
LINE
IN-WALL INDIRECT
DRAIN LINE FROM
ICE DISPENSER TO
FLOOR SINK
SECTION A - PLUMBING DIAGRAM
SKIRT TO
DOOR FACE W/
TAPERED EDGE
PULL
MOUNTING
TEMPLATE, BLACK
IN-WALL BLOCKING
REQUIRED,
PROVIDED BY G.C.
OUTLET BOX FOR
INDIRECT DRAIN
LINE
11'-8"INDIRECT LINE FROM
DRAINBOARD TO FLOOR
SINK
HOT AND NON-FILTERED COLD
WATER FOR SINK FAUCET AT
20 1/2" (20MM) A.F.F. SHUT-OFF
VALVES AT WALL AND 4" (100MM)
EITHER SIDE OF WASTE LINE
NON-FILTERED COLD WATER SUPPLY
FOR BLENDER PITCHER RINSER
INDIRECT DRAIN LINE FROM SINK
TO FLOOR SINK
FILTERED COLD WATER
SUPPLY FOR WATER TOWER
FAUCET
CEILING
IN-WALL INDIRECT
DRAIN LINE FROM
ICE DISPENSER TO
FLOOR SINK
OUTLET BOX FOR
INDIRECT DRAIN
LINE
OUTLET BOX FOR
INDIRECT DRAIN
LINE
FLOOR SINK
DRAIN LINES FROM
DRAIN TRAY AND
UNDERCOUNTER
REFRIGERATOR;
SEPARATE,
INDIRECT
TERMINATION AT
FLOOR SINK
SEE PLUMBING PLAN FOR FINAL
FLOOR SINK LOCATION AND TYPE
ELEVATION - PLUMBING DIAGRAM
A
ICE TRANSPORT TUBE
LANE 1, TO ICE
DISPENSER. MAX
LENGTH 75', MIN. SLOPE
1/4":1'.
IN-WALL CONTINUOUS
CONDUIT FASTENED W/
STRAPING @ 48" O.C. MIN.
VA
R
I
E
D
1" = 1'-0"3BOOSTER PUMP - PLUMBING
3/4" = 1'-0"2MOP SINK (STACKED) - PLUMBING
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
Revision Schedule
Rev Date By Description
March 24
CH
E
C
K
S
E
T
-
0
3
/
2
2
/
2
0
2
4
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
76085-018
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
3/4" = 1'-0"1CBE 15-01 PLUMBING
PLUMBING DETAILS
P-503
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
5
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
Revision Schedule
Rev Date By Description
March 24
CH
E
C
K
S
E
T
-
0
3
/
2
2
/
2
0
2
4
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
76085-018
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
PROVIDE ONE PIECE SPUN ALUMINUM BASE WITH, GRADUATED
STEPPED PVC BOOT, AND ADJUSTABLE STAINLESS STEEL
CLAMPS. SET BASE IN BED OF MASTIC
FLOOR SLAB ON GRADE
REFER TO ARCHITECT'S
DRAWING FOR APPLICATION
INSTALLATION WITH
OF VENT PIPE BOOT
ROOFING MATERIAL
ROOF INSULATION
ROOF DECK
OF ROOF DECK
PROVIDE SLEEVE IF ANCHOR PIPE TO ROOF
MINIMUM 12" BELOW ROOF
REQUIRED BY TYPE
PROVIDE PIPE INCREASER
WHERE REQUIRED TO MAKE
MINIMUM 3" VENT THRU ROOF
DECK OR JOISTS WITH
WELDED OR SCREWED
U-BOLT AROUND PIPE
AND ANGLE IRON
TO DECK OR JOIST
HUBLESS PIPE
CONNECTORS ON
CAST IRON PIPE
REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR MINIMUM
TEN FEET HORIZONTAL OR THREE FEET VERTICAL ABOVE ANY BUILDING
OPENING OR FRESH AIR INTAKE, AND ONE FOOT FROM ANY VERTICAL SURFACE.
PROVIDE 1" FIBERGLASS INSULATION WITH ALL- SERVICE JACKET ON VENT PIPE
INSIDE BUILDING WITHIN SIX FEET OF VENT THRU ROOF LOCATION. VERIFY
FLASHING AND COUNTERFLASHING WITH ROOFING CONTRACTOR.
NOTES:
1.
2.
3.
4.
5.
6.
7.
5 VENT THRU ROOF
12" = 1'-0"4
NO-HUB
SEE SCHEDULE
SANITARY OR STORM
SEWER LINE
LONG SWEEP ELBOW AT
END OR TURN OF RUN
DIRECTION
OF FLOW
COMBINATION WYE AND
EIGHTH BEND IN RUN.
ENTER TOP OF PIPE
MINIMUM 12"
ABOVE ROOF
DEPTH OF SEWER
AS REQUIRED FOR
SAME SIZE AS SEWER UP
TO 4" MAXIMUM
MEMBRANE CLAMP
PROVIDE ROUND SECURED NICKEL BRONZE ADJUSTABLE TOP WITH "CO" CAST IN COVER.
PROVIDE CLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET MARKER,
RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS).
PROVIDE BRONZE PLUG IN CAST IRON BODY.
LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE GREATER THAN 45 DEGREES, AT 50'
INTERVALS ON STRAIGHT RUNS, AND WHERE SHOWN ON PLANS.
PROVIDE BACKFILL PER ARCHITECTURAL SPECIFICATIONS.
LOCATE CLEANOUTS WHERE THERE IS 18" CLEAR AROUND.
CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS.
FLOOR CLEANOUT
12" = 1'-0"
1/2" TEMPERED HW SUPPLY
THERMOSTATIC MIXING VALVE
SET TEMPERATURE TO 110°F
P-TRAP
1/2" CW SUPPLY
PROVIDE METAL 360° INSULATION
SHIELD AND HIGH DENSITY INSULATION
OR PRE-ENGINEERED THERMAL HANGER
SHIELD INSERT OF CALCIUM SILICATE
INSULATION. FOR PIPES 4" AND SMALLER
PRE-ENGINEERED THERMAL HANGER SHIELD
INSERT OF FLEXIBLE UNICEULAR
INSULATION MAY BE PROVIDED
CUT INSULATION TO FIT AROUND
TRAPEZE HANGER. SEAL BOTH ENDS
OF EXPOSED INSULATION WITH
JOINT SEALANT
SIZE AND QUANTITY OF
HANGER RODS PER
MANUFACTURER'S
RECOMMENDATIONS
PROVIDE TWO-PIECE
PIPE CLAMP (TYP)
SUPPORT NUT
(TYP)
UNINSULATED STEEL
OR PLASTIC PIPE
UNINSULATED COPPER
PIPE
PROVIDE PLASTIC
GALVANIC ISOLATOR
FOR COPPER PIPE (TYP)
COLD INSULATED PIPE
TMV
-
1/2" HW
NOTES:
1.
NOTES:
1.
2.
SEE MATERIAL MATRIX FOR PIPE MATERIAL AND JOINING METHOD.
TMV TO HAVE A MINIMUM FLOW LESS THAN OR EQUAL TO ONE FAUCET'S MINIMUM FLOW
LAVATORY TAILPIPE AND HOT WATER LINES SHALL BE INSULATED OR COVERED PER CBC 11B-606.5.
2.
3.
4.
5.
6.
PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. REFER TO
SPECIFICATIONS FOR MORE INFORMATION.
PIPE AND CONDUIT OF ALL TRADES MAY BE COMBINED ON THE SAME SUPPORT CHANNEL.
COORDINATE SUPPORT CHANNEL LENGTH WITH PIPING AND CONDUIT TO BE SUPPORTED.
SUPPORT CHANNEL SPACING SHALL BE DETERMINED BY SMALLEST PIPE TO BE SUPPORTED.
CHANNEL SUPPORT MAY BE USED AS A WALL BRACKET, ATTACH TO WALL WITH ANCHOR BOLTS PER
SPECIFICATIONS.
FOR HORIZONTAL INSULATED PIPING, ATTACH CLAMPS AS INDICATED ABOVE, FOR VERTICAL INSULATED
PIPING, ATTACH CLAMPS TO THE PIPE AND SEAL INSULATION AT BOTH CLAMP ENDS.
3 PUBLIC LAVATORY & HAND SINK W/ TMV
1" = 1'-0"1 MULTIPLE PIPE TRAPEZE HANGER
12" = 1'-0"
ANCHOR - PER NFPA
6 PIPE HANGAR
12" = 1'-0"
ON INSULATED PIPE. PROVIDE
PIPE SUPPORT SHIELD.
HANGER - GRINNEL FIG. 69
3/8" ALL-THREAD ROD FOR <=4" PIPE.
FOR LARGER PIPE SIZES SEE NFPA 13.
NOTE:
BUILDING STRUCTURE MAY VARY
MATCH INSTALLATION TO BUILDING
STRUCTURE REFER TO STRUCTURAL
DRAWINGS FOR ATTACHMENT.
1/2" CW PROVIDE 1-5/8"x1-5/8" 14
GA. CHANNEL SUPPORT
PIPE INSULATION (TYP)
HOT INSULATED PIPE
2 ECO-GRIP CLAMPING FLOOR SINK DETAIL
12" = 1'-0"
3" TAIL PIECE
NO-HUB
CONNECTION
GRAVEL
BACKFILL
CONC INFILL AND
TRENCH FOR
BELOW GRADE
UTILITIES
STAINLESS STEEL FLOOR
SINK W/CLAMPING FEATURE
FLOOR SINK HALF GRATE
FLUSH WITH FLOOR FINISH
3.
PLUMBING DETAILS
P-504
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
5
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024
1
1
2 2
(E) 4" SS
(E) 2'' BFP
(E) 2'' WATER
METER
3
GI-1
4
2
GB-75 GREASE
INTERCEPTOR
3" V B.G.
SAMPLE BOX
SV-10
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
Revision Schedule
Rev Date By Description
March 24
CH
E
C
K
S
E
T
-
0
3
/
2
2
/
2
0
2
4
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
A
N
T
A
AN
A
,
C
A
,
9
2
7
0
5
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
76085-018
51969
CHARLIE CHANG
AMY YANG
MAGED GERGES
PLUMBING SITE PLAN
PS-100
N
3/32" = 1'-0"1PLUMBING SITE PLAN
GENERAL NOTES
1
PLUMBING PLAN KEY NOTES
2
3
A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT
NECESSARILY SHOWN.
B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK
TO REVEAL FULL SCOPE OF WORK.
C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS
EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS.
D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS
OTHERWISE NOTED.
E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.
F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK.
G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2"
(10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO
SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS.
H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS
LISTED IN THE PROJECT MANUAL.
I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF
WATER FILTRATION SYSTEM.
J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW
TO RENOVATED SYSTEMS.
CONTRACTOR SHALL FIELD VERIFY ALL PIPE CONDITIONS PRIOR TO CONSTRUCTION ,
INCLUDING EXACT LOCATION, AVAILABLE INVERT, DIRECTION OF FLOW, AND CAPACITY FOR
THE ADDED FIXTURE LOAD FROM THIS T.I..
SEE P-200 PLUMBING WASTE PLAN FOR CONTINUATION.
SEE P-100 PLUMBING WATER PLAN FOR CONTINUATION.
INSTALL NEW GREASE INTERCEPTOR.4
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
S
E
T
-
0
4
/
1
6
/
2
0
2
4
5
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
TU
S
T
I
N
&
S
A
N
T
A
CL
A
R
A
23
0
1
N
T
U
S
T
I
N
A
V
E
,
S
U
I
T
E
A
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
5
STORE #:
PROJECT #:
ISSUE DATE:
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
76085-018
04-15-2024
51969
CHARLIE CHANG
SEPIDEH SHARIFI
MAGED GERGES
2301 N Tustin Ave
#A8/22/2024