HomeMy WebLinkAbout210 W Harvey Ave Unit #2 - Plan210 W Harvey Ave Unit #24/22/2025 210 W Harvey Ave Unit #24/22/2025 210 W Harvey Ave Unit #24/22/2025 210 W Harvey Ave Unit #24/22/2025 210 W Harvey Ave Unit #24/22/2025 210 W Harvey Ave Unit #24/22/2025 210 W Harvey Ave Unit #24/22/2025 210 W Harvey Ave Unit #24/22/2025 210 W Harvey Ave Unit #24/22/2025 210 W Harvey Ave Unit #24/22/2025 210 W Harvey Ave Unit #24/22/2025 GENERAL NOTES FRAMING LUMBER 1. 2. 3. 4. 6. 5. 7. 8. 9. 10. 12. 13. 14. 15. 16. 2. 3. 4. 5. 1. 1. 11. ALL STRUCTURAL LUMBER SHALL BE (DOC PS20 OR EQUIVALENT) DOUGLAS FIR LARCH OF THE FOLLOWING MINIMUM GRADES: A. 2X FRAMING INCLUDING PLATES AND STUDS NO. 2 B. 4X BEAMS AND HEADERS UP TO 4X12 NO. 2 C. LARGER THAN 4X12 AND POSTS NO. 1 D. 6X AND LARGER BEAMS NO. 1 STRUCTURE PANELS SHALL BE DOUGLAS FIR CONFORMING TO U.S. PRODUCT STANDARD DOC PS1 OR DOC PS2 OR ANSI/APA PRP210, AND SHALL BEAR THE STAMP OF AN APPROVED FABRICATOR. INSTALLATION OF VERTICAL AND HORIZONTAL SHEATHING SHALL FIRST BE APPROVED BY THE INSPECTOR PRIOR TO COVERING. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY SHOWN ON APPROVED PLANS. MAXIMUM MOISTURE CONTENT OF ALL MUMBER SHALL BE 19%. BOLT HOLES TO BE NOMINAL DIAMETER OF BOLT PLUS 1/16 INCH UNLESS NOTED OTHERWISE. PROVIDE WASHERS UNDER HEAD AND NUTS OF BOLTS AND LAG SCREWS. FRAMING CONNECTIONS SHALL BE "SIMPSON STRONG-TIE". THE NUMBER OF NAILS CONNECTING LUMBER SHALL NOT BE LESS THAN THE MINIMUM REQUIRED ON CRC R602.3(1). ALL NAILS USED ON STRUCTURAL PANELS SHALL BE COMMON NAILS. PROVIDE CONTINUOUS EDGE SUPPORT ALONG TOP AND BOTTOM OF 2X14 JOISTS. BUILT-UP FRAMING MEMBERS SHALL BE CONNECTED AS FOLLOWS: A. 2-2X 16D AT 12" O.C. STAGGERED TOP AND BOTTOM. B. 3-2X 5/8" DIA. M.B. AT 18" O.C. STAGGERED TOP AND BOTTOM. C. 4-2X 5/8" DIA. M.B. AT 18" O.C. STAGGERED TOP AND BOTTOM. PROVIDE DOUBLE JOISTS UNDER PARALLEL PARTITIONS. PROVIDE SOLID BLOCKING UNDER ALL NON-PARALLEL PARTITIONS. INSTALL LAG BOLTS BY DRILLING LEAD HOLE 65% TO 75% OF SHANK DIAMETER AND FULL DIAMETER FOR SHANK PORTION. USE SOAP OR OTHER APPROVED LUBRICANT ON THREADS. INSTALLATION SHALL BE BY TIGHTENING OF SCREW NOT BY HAMMERING. TRUSS JOISTS SHOP DRAWINGS SHALL BE PROVIDED BY THE SUPPLIER AND SUBMITTED TO THE BULIDING DEPARTMENT FOR APPROVAL PRIOR TO FABRICATION. SHOP DRAWINGS SHALL BE STAMPED AND WET SIGNED BY A LICENSED ENGINEER. DOUBLE TOP PLATES WITH END JOINTS OFFSET BY 48" MIN. FOR STUD WALL GLULAM/PARALLAM/MICROLAM BEAMS GLUE LAMINATED BEAMS SHALL BE PER CBC (AITC A190.1 & ASTM 3737) AND AMERICAN INSTITUTE OF TIMBER CONSTRUCTION 117. CONBINATION SYMBOLS SHALL BE AS FOLLOWS: A) 24F-V4 DF/DF FOR SIMPLE BEAMS B) 24F-V8 DF/DF FOR CANTILEVERED BEAMS PARALLAM BEAMS SHALL BE 2.0E PSL I LEVEL, ICC ESR- 1387 MICROLAM BEAMS SHALL BE 2.0E LVL LAMINATED BEAMS SHALL BE FABRICATED BY A LICENSED FABRICATOR AND SHALL BE ACCOMPANIED TO THE JOB SITE WITH CERTIFICATE OF FABRICATION. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT OR ENGINEER FOR REVIEW PRIOR TO FABRICATION. STRUCTURAL AND MISCELLANEOUS STEEL 2. 3. 4. 5. 6. 7. 8. 9. ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL CONFORM TO A.S.T.M. A-36 AND SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE A.I.S.C. SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDING, LATEST EDITION. PIPE COLUMNS SHALL CONFORM TO A.S.T.M. A-53 GRADE B. TUBULAR STEEL SHALL CONFORM TO A.S.T.M. A500 GRADE B. BOLTS SHALL CONFORM TO A.S.T.M. A-307 UNLESS NOTED OTHERWISE. SHOP DRAWING SHALL BE SUBMITTED TO THE ARCHITECT AND ENGINEER AND BUILDING DEPARTMENT FOR REVIEW PRIOR TO FABRICATION. FABRICATION SHALL BE DONE IN THE SHOP OF LICENSED FABRICATORS. USE ELECTRIC ARC PROCESS WELDING WITH E70XX ELECTRODES. ALL WELDING SHALL BE DONE IN THE SHOP OF LICENSED FABRICATOR OR PROVIDE CONTINUOUS SPECIAL INSPECTION BY A RESGISTERED DEPUTY INSPECTOR. WHERE A FILLET WELD SYMBOL IS USED IN THE PLANS WITHOUT INDICATION OF SIZE, THE MINIMUM WELD SIZE AS SPECIFIED IN THE A.I.S.C. MANUAL OF STEEL CONSTRUCTION SHALL BE USED. 9.ENCLOSED USABLE SPACE UNDER STAIRWAY REQUIRES ONE HOUR CONSTRUCTION ON ENCLOSED SIDE 17. 1. 2. PROVIDE HOSE BIBB WITH NON-REMOVABLE BACK FLOW PREVENTED @ DWELLING. PLUMBING REQUIREMENT: NOTES CONTROL VALVER FOR SHOWER(TUB- SHOWER SHALL BE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE MAX. FLOW RATE WC. = 1.28 GPM. SHOWER HEAD =1.8 GPM USE 2- 15 # FEET WHEN STUCCO IS APPLIED OVER PLYWOOD 1. 2. 3. 4. SHOWERS SHALL BE FINISHED 72" ABOVE DRAIN W/ SURFACE MATERIAL NOT ADVERSELY EFFECTED BY MOISTURE 5.WATER HEATER MUST HAVE A PRESSURE AND A TEMPERATURE RELIEF VALVE PLUMBED TO THE OUTSIDE OF THE BUILDING 12" MIN. ACCESS PANEL IS REQUIRED FOR THE BATHTUB TRAP SLIP JOINT. CLEANOUT IN UNDERFLOOR PIPING SHALL BE EXTENDED TO OR ABOVE THE FLOOR OR EXTENDED TO THE EXTERIOR OF THE BUILDING UNLESS: AN 18" X30" CLEARANCE IS PROVIDED FROM THE MEANS OF ACCESS. IN ADDTION, NO CLEAN OUT SHALL BE MORE THAN 20'-0" FROM THE ACCESS OPENING. WATER HEATER WILL HAVE AN R-16 BLANKET OR BE RATED FOR R-16 8. 6. 7. SHOWER AND BATHTUB DOORS AND THE ENCLOSURES TEMPERED GLASS AT COUNTER SPACE IN KITCHEN AND DINING AREA, RECEPTACLE SHALL BE PROVIDED AS FOLLOWS: RECEPTACLE SHALL BE PROVIDED SO THAT NO POINT ALONG THE WALL IS MORE THAN 24" FROM A RECEPTACLE RECEPTACLES OUTLETS SHALL BE PLACED @12'-0" MAXIMUM AND SHALL BE LOCATED WITH 6'-0" OF DOOR OPENINGS. DETECTORS MUST RECEIVE POWER FROM THE BUILDING WIRING, WITH BATTERY BACKUP WITHOUT A DISCONNECTING SWITCH, OTHER THAN FOR OVER OVER CURRENT PROTECTION, EXCEPT THAT IN THE EXISTING PORTION OF AN EXISTING BUILDING (NOT IN AN ADDITION), THEY MAY BE BATTERY OPERATED (CRC SEC. R314). 3. RECEPTACLE/OUTLET: 2. 1. PROVIDE HEATING TO PRODUCE REQUIRED ROOM TEMPERATURE OF 70 DEGREE @ 3 FEET ABOVE FLOOR. 1. MECHANICAL REQUIREMENT: SERVICE: DOORS & WINDOWS IN ALL BEDROOMS, PROVIDE ON OPENABLE ESCAPE WINDOW MEETING ALL OF THE FOLLOWING: AN OPENABLE AREA OF NOT LESS THAN 5.7 SQ. FT., A MINIMUN CLEAR 24 INCHES HEIGHT AND 20 INCHES WIDTH AN A SILL HEIGHT NOT OVER 44 INCHES ABOVE THE FLOOR. GLAZING ADJACENT TO DOORS, SHALL MEET WITH CRC308.4.2. STRUCTURE NOTES: CONCRETE: REINFORCING STEEL: ASTM A615, GRADE #60. #4 AND SMALLER, GRADE #40.A. CONCRETE NORMAL WEIGHT WITH COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS. WATER-CEMENT RATIO 0.45 AND CEMENT TYPE V OR PER SOILS REPORT. B. FOR STEM WALLS LONGER THAN 24", PROVIDE #4 VERTICAL BARS @ 24" O.C.C. LANDING 3 1/2" CONC W/ 6X6 10X10 MESH.STEEL:D. SHAPED AND PLATE: ASTM A36; TUBE: ASTM A500, GRADE B.1. BOLTS: ASTM A307.2. WOOD: FRAMING MEMBERS : DOUGLAS FIR LARCH (DOC PS20)A. COLUMNS, BEAMS, HEADERS, AND PLATES : NO 1B. STUDS, JOISTS, RAFTERS, BLOCKINGS: NO 2C. WALL SILLS, NAILERS, AND LEDGERS IN CONTACT WITH CONCRETE: PRESERVATIVE TREATED DOUGLAS FIR. D. FRAMING CONNECTION HARDWARE: AS MANUFACTURED BY SIMPSON STRONGTIE CO. OR APPROVED EQUIVALENTS. SIMPSON DESIGNATIONS USED. USE NAILS PER ICC APPROVAL AND AS RECOMMENDED BY SIMPSON FOR EACH DEVICE. E. COMMON NAILS, UNLESS OTHERWISE NOTED, ALL NAILING TO BE PER CRC TABLE R602.3(1), UNLESS OTHERWISE NOTED. F. EXPOSED TO WEATHER: ALL EXPOSED STEEL MEMBERS SHALL BE COATED WITH A ZINC RICH PRIMER.A. ALL EXTERIOR HANGERS AND OTHER SIMPSON TYPE PRODUCTS SHALL BE GALVANIZED.B. ALL PLYWOOD SHALL BE OF AN EXP. 1 GRADE.C. FRAMING: DOUBLE FLOOR JOISTS REQUIRED UNDER PARALLEL BEARING WALLS.A. APPLY CONT. LINE OF GLUE TO FLOOR PANELS AT ALL JOIST.B. BLOCKING ARE REQUIRED AT ALL SHEAR WALL PANEL EDGES.C. CONSTRUCT OF PLYWOOD SHEAR WALL SHALL BE WITH COMMON NAILS ONLY.D. HOLD DOWN BOLT HOLES AT EACH END OF THE PLYWOOD SHEAR WALL SHALL HAVE TOLERANCE OF NO MORE THAN 1/16". E. ALL POSTS WITH HOLD DOWNS OR UPLIFT STRAPS SHALL HAVE CONTINUOUS EDGE NAILING. F. ALL ANCHOR BOLTS SHALL BE ATTACHED TO THE SILL PLATE WITH 3"X3"X.229" STEEL PLATE WASHERS. G. HORIZONTAL PLYWOOD SHEARTHING: VERTICAL PLYWOOD SHEATHING: (DOC PS1 OR PS2) (SEE SCHEDULE).A. EXTERIOR STUCCO NOTES: CRC SECTION R703 STUCCO LATH AND DRYWALL SHALL BE NAILED TO ALL STUDS AND TO TOP AND BOTTOM PLATES A. 7.FOUNDATION PLATES OR SILLS BOLTED WITH 5/8" DIA. X 12" ANCHOR BOLTS W/ 7" MIN. EMBEDMENT AT NOT MORE THAN 4'-0" O.C. ONE BOLT IS REQUIRED WITHIN 12" OF EACH END OF EACH MEMBER AND A MIN. OF 2 BOLTS ARE REQUIRED PER MEMBER (SEC. 2304.3.4 CBC). FASTENERS SHALL BE HOT- DIPPED ZINC- COATED GALVANIZED STEEL. CONCRETE: f'c=4500 PSI, w/c=0.45 AND TYPE V CEMENT 8. 1. 2. FOUNDATION 4. 5. 6. IN LIEU OF A SOIL REPORT, FOUNDATION HAVE BEEN DESIGNED USING MAX ALLOWABLE SOIL BEARING CAPACITY OF 1,500 PSI. FOUNDATION DESIGN IS BASED ON NON-EXPANSIVE SOIL. EXISTING FOUNDATIONS ARE ASSUMED TO BE IN GOOD CONDITION. CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY FOUNDATION WITH SIGNIFICANT SETTLEMENT, SEVERE CRACKING OR ANY INDICATION OF STRUCTURAL FAILURE OR DISTRESS OR DEFECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING, FENCE ENCLOSURES AND PROTECTION LIFE AND PROPERTY UNTIL THE PROJECT IS COMPLETE. 3. THE ARCHITECTURAL FLOOR PLAN AND NOTIFY THE PROJECT DESIGNER OF ANY DISCREPANCIES PRIOR TO STARTING WORK. TREATED LUMBER CONFORMING TO (CRC) FOR FOUNDATION PLATES AND SILL 1. 2. 3. 5. 7. 8. 6. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE 2022 CALIFORNIA RESIDENTIAL CODES AND ALL AMENDMENTS AND LOCAL, COUNTY, STATE AND FEDERAL REGULATIONS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO BID AND SIGNING OF CONTRACT. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT AND ENGINEER AND BE RESOLVED IN WRITING BEFORE PROCCEDING WITH THE WORK. GENERAL NOTES AND TYPICAL DETAILS SHALL APPLY TO ALL PARTS OF THE JOB EXCEPT WHERE THEY ARE IN CONFLICT WITH DETAILS AND NOTES ON OTHER DOCUMENTS; THE MORE STRICT CONDITION APPLIES SUBJECT TO REVIEW BY THE ENGINEER. ALL INFORMATION SHOWN ON THE PLANS RELATIVE TO EXISTING CONDITION WERE CAREFULLY TAKEN IN THE FIELD BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS ARE IN CONFLICT WITH THE PLANS, THEY SHALL BE REPORTED TO THE ENGINEER SO THAT PROPER CHANGES CAN BE MADE. REQUIRED SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR REVIEW. MODIFICATION OF STRUCTURAL PLANS AND MATERIAL SUBSTITUTIONS SHALL NOT BE DONE WITHOUT WRITTEN APPROVAL OF THE ENGINEER. THE APPROVED PLANS AND SPECIFICATIONS REPRESENT THE FINISH STRUCTURE AND DO NOT INCLUDE THE METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION METHODS, MEANS, TECHINQUES, SEQUENCES AND PROCEDURES INCLUDING BUT NOT LIMITED TO SHORING, INSURANCE, FENCING, CONSTRUCTION CANOPY, SCAFFOLDING ETC. FIELD OBSERVATIONS BY THE ENGINEER SHALL NOT BE CONSIDERD AS INSPECTIONS AS REQUIRED BY THE CODE. REFER TO THE ARCHITECTURAL PLANS FOR DIMENSIONS, OPENINGS, LAYOUT ETC. 4. REINFORCING STEEL 1. 2. 3. 4. 5. 6. 7. 9. 8. REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO THE REQUIREMENTS OF A.S.T.M. A-615 GRADE 60 FOR BARS LARGER THAN #4, GR.40 FOR #4 OR SMALLER. WELDED WIRE FABRIC SHALL CONFORM TO A.S.T.M. A-82 AND A-185 . LAP 12 INCHES MINIMUM. DELTAILING,FABRICATION AND ERECTION OF REINFORCING BARS SHALL CONFORM TO THE LATEST EDITION OF A.C.I. MANUAL OF STANDARD PRACTICE FOR DETAILING AND REINFORCED CONCRETE STRUCTURES. MINIMUM COVER FORCAST IN PLACE CONCRETE SHALL BE AS FOLLOWS: A. POURED AGAIN EARTH 3 INCHES B. POURED AGAIN FORM BELOW GRADE 2 INCHES C. FORMED SLABS 3/4 INCH D. SLAB ON GRADE, TOP COVER 1 INCH E. COLUMN AND BEAM MAIN BARS 1-1/2 INCHES F. WALLS EXPOSED TO WEATHER # 6 AND LARGER 2 INCHES # 5 AND SMALLER 1-1/2 INCHES BARS SHALL BE CLEAN OF RUST, GREASE AND OTHER DELETERIOUS MATERIAL THAT MAY AFFECT BOND. ALL BEND SHALL BE MADE COLD. LAP SPLICE LENGTH SHALL BE 40 BARS DIAMETERS MINIMUM AND SHALL BE STAGGERED. ALL REINFORCING BARS, EMBEDS, ANCHOR BOLTS, HOLDOWNS ETC. SHALL BE SECURED IN PLACE PRIOR TO PLACEMENT OF CONCRETE. CODE REQUIRED INSPECTIONS BY JURISTDICTION AUTHORITY SHALL BE MADE AN SIGNED OFF PRIOR TO PLACEMENT OF CONCRETE. 3.5.0 SQ. FT. AT GRADE LEVEL. USE GRADE "D" PAPER BACKING WHEN STUCCO IS APPLIED OVER PLYWOOD (CRC).B. ELECTRICAL REQUIREMENT: A, B, C BLOCKING BETWEEN CEILING JOISTS, RAFTERS OR TRUSSES TO TOP PLATE OR OTHER FRAMING BELOW 1 TOE NAIL EACH END TOE NAIL 6" O.C. FACE NAIL PER JOIST, TOE NAIL2 3 STUD TO STUD (NOT AT BRACED WALL PANELS)8 24" O.C. FACE NAIL 16" O.C. FACE NAIL STUD TO STUD AND ABUTTING STUDS AT INTERSECTING WALL CORNERS (AT BRACED WALL PANELS) 9 12" O.C. FACE NAIL 16" O.C. FACE NAIL BUILT-UP HEADER (2" TO 2" HEADER WITH 1/2" SPACER)10 16" O.C. EACH EDGE FACE NAIL 12" O.C. EACH EDGE FACE NAIL CONTINUOUS HEADER TO STUD11 TOE NAIL TOP PLATE TO TOP PLATE13 DOUBLE TOP PLATE SPLICE FACE NAIL ON EACH SIDE OF END JOINT (MINIMUM 24" LAP SPLICE LENGTH EACH SIDE OF END JOINT) BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (NOT AT BRACED WALL PANELS) 15 BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (AT BRACED WALL PANEL) 16 16" O.C. FACE NAIL TOP OR BOTTOM PLATE TO STUD17 TOE NAIL END NAIL TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS18 FACE NAIL 1" BRACE TO EACH STUD AND PLATE19 FACE NAIL 1" X 6" SHEATHING TO EACH BEARING20 FACE NAIL 1" X 8" AND WIDER SHEATHING TO EACH BEARING21 FACE NAIL JOIST TO SILL, TOP PLATE OR GIRDER22 TOE NAIL RIM JOIST, BAND JOIST OR BLOCKING TO SILL OR TOP PLATE (ROOF APPLICATIONS ALSO) 23 4" O.C. TOE NAIL 6" O.C. TOE NAIL 1" X 6" SUBFLOOR OR LESS TO EACH JOIST24 FACE NAIL 14 2" SUBFLOOR TO JOIST OR GIRDER25 BLIND AND FACE NAIL 2" PLANKS (PLANK & BEAM — FLOOR & ROOF)26 AT EACH BEARING, FACE NAIL BAND OR RIM JOIST TO JOIST27 END NAIL BUILT-UP GIRDERS AND BEAMS, 2-INCH LUMBER LAYERS 28 FACE NAIL AT ENDS AND AT EACH SPLICE NAIL EACH LAYER AS FOLLOWS: 32" O.C. AT TOP & BOTTOM & STAGGERED. 24" O.C. FACE NAIL AT TOP & BOTTOM STAGGERED ON OPPOSITE SIDES LEDGER STRIP SUPPORTING JOISTS OR RAFTERS29 AT EACH JOIST OR RAFTER, FACE NAIL BRIDGING TO JOIST30 EACH END, TOE NAIL A, B, C H C, E 3/8" – 1/2"31 6D COMMON OR DEFORMED (2" x 0.113" x 0.266" HEAD); OR 2 3/8" x 0.113" x 0.266" HEAD NAIL (SUBFLOOR, WALL) 8D COMMON (2 1/2" X 0.131") NAIL (ROOF)' OR RSRS-01 (2 3/8" x 0.113") NAIL (ROOF) 8D COMMON (2 1/2" X 0.131") NAIL (SUBFLOOR, WALL) 10D COMMON (3" X 0.148") NAIL; OR 8D (2 1/2" X 0.131") DEFORMED NAIL 1 1/2" x 0.120" GALVANIZED ROOFING NAIL, 7/16" HEAD DIAMETER; OR 1 1/4" LONG 16 GA. STAPLE WITH 7/16" OR 1" CROWN 1 3/4" x 0.120" GALVANIZED ROOFING NAIL, 7/16" HEAD DIAMETER; OR 1 1/4" LONG 16 GA. STAPLE WITH 7/16" OR 1" CROWN 1 1/2" x 0.120" GALVANIZED ROOFING NAIL, 7/16" HEAD DIAMETER; OR 1 1/4" LONG 16 GA.; 8D COMMON (2 1/2" X 0.131") NAIL 8D DEFORMED (2 1/2" X 0.131") NAIL; OR 10D COMMON (3" X 0.148" ) NAIL; OR DEFORMED (2" X 0.113"); OR I 6 6 F 6 12 9/32" – 3/4"32 7/8" – 1 1/4"33 G 1/2" STRUCTURAL CELLULOSIC FIBERBOARD SHEATHING 34 3 6 3 6 7 7 7 7 25/32" STRUCTURAL CELLULOSIC FIBERBOARD SHEATHING 35 1/2" GYPSUM SHEATHING36 5/8" GYPSUM SHEATHING37 D D 6 12 6 12 6 12 3/4" AND LESS38 7/8" – 1"39 1 1/8" – 1 1/4"40 FOR SI: 1 INCH = 25.4 MM, 1 FOOT = 304.8 MM, 1 MILE PER HOUR = 0.447 M/S; 1 KSI = 6.895 MPa. A. NAILS ARE SMOOTH-COMMON, BOX OR DEFORMED SHANKS EXCEPT WHERE OTHERWISE STATED. NAILS USED FOR FRAMING AND SHEATHING CONNECTIONS ARE CARBON STEEL AND SHALL HAVE MINIMUM AVERAGE BENDING YIELD STRENGTHS AS SHOWN: 80 KSI FOR SHANK DIAMETER OF 0.192 INCH (20D COMMON NAIL), 90 KSI FOR SHANK DIAMETERS LARGER THAN 0.142 INCH BUT NOT LARGER THAN 0.177 INCH, AND 100 KSI FOR SHANK DIAMETERS OF 0.142 INCH OR LESS. CONNECTIONS USING NAILS AND STAPLES OF OTHER MATERIALS, SUCH AS STAINLESS STEEL, SHALL BE DESIGNED BY ACCEPTED ENGINEERING PRACTICE OR APPROVED UNDER SECTION R104.11. B. SRSRS-01 IS A ROOF SHEATHING RING SHANK NAIL MEETING THE SPECIFICATIONS IN ASTM F1667. C. NAILS SHALL BE SPACED AT NOT MORE THAN 6 INCHES ON CENTER AT ALL SUPPORTS WHERE SPANS ARE 48 INCHES OR GREATER. D. FOUR-FOOT BY 8-FOOT OR 4-FOOT BY 9-FOOT PANELS SHALL BE APPLIED VERTICALLY. E. SPACING OF FASTENERS NOT INCLUDED IN THIS TABLE SHALL BE BASED ON TABLE R602.3(2). F. FOR WOOD STRUCTURAL PANEL ROOF SHEATHING ATTACHED TO GABLE END ROOF FRAMING AND TO INTERMEDIATE SUPPORTS WITHIN 48 INCHES OF ROOF EDGES AND RIDGES, NAILS SHALL BE SPACED AT 4 INCHES ON CENTER WHERE THE ULTIMATE DESIGN WIND SPEED IS GREATER THAN 130 MPH IN EXPOSURE B OR GREATER THAN 110 MPH IN EXPOSURE C. G. GYPSUM SHEATHING SHALL CONFORM TO ASTM C1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C1280OR GA 253. FIBERBOARD SHEATHING SHALL CONFORM TO ASTM C208. H. SPACING OF FASTENERS ON FLOOR SHEATHING PANEL EDGES APPLIES TO PANEL EDGES SUPPORTED BY FRAMING MEMBERS AND REQUIRED BLOCKING AND AT FLOOR PERIMETERS ONLY. SPACING OF FASTENERS ON ROOF SHEATHING PANEL EDGES APPLIES TO PANEL EDGES SUPPORTED BY FRAMING MEMBERS AND REQUIRED BLOCKING. BLOCKING OF ROOF OR FLOOR SHEATHING PANEL EDGES PERPENDICULAR TO THE FRAMING MEMBERS NEED NOT BE PROVIDED EXCEPT AS REQUIRED BY OTHER PROVISIONS OF THIS CODE. FLOOR PERIMETER SHALL BE SUPPORTED BY FRAMING MEMBERS OR SOLID BLOCKING. I. WHERE A RAFTER IS FASTENED TO AN ADJACENT PARALLEL CEILING JOIST IN ACCORDANCE WITH THIS SCHEDULE, PROVIDE TWO TOE NAILS ON ONE SIDE OF THE RAFTER AND TOE NAILS FROM THE CEILING JOIST TO TOP PLATE IN ACCORDANCE WITH THIS SCHEDULE. THE TOE NAIL ON THE OPPOSITE SIDE OF THE RAFTER SHALL NOT BE REQUIRED. 4-8D BOX (2 1/2" X 0.113") OR 3-8D COMMON (2 1/2" X 0.131"); OR 3-10D BOX (3" X 0.128"); OR 3-3" X 0.131" NAILS 16D BOX (3-1/2" X 0.162"); OR 3" X 0.131" NAILS 2-8D COMMON (2 1/2" X 0.131") OR 2-3" X 0.131" NAILS 2-16D COMMON (3-1/2" X 0.162"); OR 3-3" X 0.131" NAILS 4-3" X 0.131" NAILS 16D COMMON (3 1/2" X 0.162") 10D BOX (3" X 0.128"); OR 3" X 0.131" NAILS 16D BOX (3 1/2" X 0.135"); OR 3" X 0.131" NAILS 16D COMMON (3 1/2" X 0.162") 16D COMMON (3 1/2" X 0.162") 16D BOX (3 1/2" X 0.135") 5-8D BOX (2 1/2" X 0.113"); OR 4-8D COMMON (2 1/2" X 0.131"); OR 4-10D BOX (3" X 0.128") 16D COMMON (3 1/2" X 0.162") 3" X 0.131" NAILS 8-16D COMMON (3 1/2" X 0.162"); OR 12-16D BOX (3 1/2" X 0.135"); OR 12-10D BOX (3" X 0.128"); OR 12-3" X 0.131" NAILS 3-16D BOX (3 1/2" X 0.135"); OR 2-16D COMMON (3 1/2" X 0.162"); OR 4-3" X 0.131" NAILS 4-8D BOX (2 1/2" X 0.113"); OR 3-16D BOX (3 1/2" X 0.135"); OR 4-8D COMMON (2 1/2" X 0.131"); OR 4-10D BOX (3" X 0.128"); OR 4-3" X 0.131" NAILS 3-16D BOX (3 1/2" X 0.135"); OR 2-16D COMMON (3 1/2" X 0.162"); OR 3-10D BOX (3" X 0.128"); OR 3-3" X 0.131" NAILS 3-10D BOX (3" X 0.128"); OR 2-16D COMMON (3 1/2" X 0.162"); OR 3-3" X 0.131" NAILS 3-8D BOX (2 1/2" X 0.113"); OR 2-8D COMMON (2 1/2" X 0.131"); OR 2-10D BOX (3" X 0.128"); OR 2 STAPLES 1 3/4" 3-8D BOX (2 1/2" X 0.113"); OR 2-8D COMMON (2 1/2" X 0.131"); OR 2-10D BOX (3" X 0.128"); OR 3-8D BOX (2 1/2" X 0.113"); OR 3-8D COMMON (2 1/2" X 0.131"); OR 3-10D BOX (3" X 0.128"); OR WIDER THAN 1" X 8" 4-8D BOX (2 1/2" X 0.113"); OR 3-8D COMMON (2 1/2" X 0.131"); OR 3-10D BOX (3" X 0.128"); OR 4-8D BOX (2 1/2" X 0.113"); OR 3-8D COMMON (2 1/2" X 0.131"); OR 3-10D BOX (3" X 0.128"); OR 3-3" X 0.131" NAILS 8D BOX (2 1/2" X 0.113") 8D COMMON (2 1/2" X 0.131"); OR 10D BOX (3" X 0.128"); OR 3" X 0.131" NAILS 3-8D BOX (2 1/2" X 0.113"); OR 2-8D COMMON (2 1/2" X 0.131"); OR 3-10D BOX (3" X 0.128"); OR 3-16D BOX (3 1/2" X 0.135"); OR 2-16D COMMON (3 1/2" X 0.162") 3-16D BOX (3 1/2" X 0.135"); OR 2-16D COMMON (3 1/2" X 0.162") 3-16D COMMON (3 1/2" X 0.162"); OR 4-10 BOX (3" X 0.128"); OR 4-3" X 0.131" NAILS; OR 4-3" X14 GA. STAPLES, 7/16" CROWN 20D COMMON (4" X 0.192"); OR 10D BOX (3" X 0.128"); OR 3" × 0.131" NAILS AND: 2-20D COMMON (4" X 0.192"); OR 3-10D BOX (3" X 0.128"); OR 3-3" X 0.131" NAILS 4-16D BOX (3 1/2" X 0.135"); OR 3-16D COMMON (3 1/2" X 0.162"); OR 4-10D BOX (3" X 0.128"); OR 4-3" X 0.131" NAILS 2-10D BOX (3" X 0.128"); OR 2 STAPLES, 1" CROWN, 16 GA., 1 3/4" LONG 3 STAPLES, 1" CROWN, 16 GA., 1 3/4" LONG 4 STAPLES, 1" CROWN, 16 GA., 1 3/4" LONG 2 STAPLES, 1" CROWN, 16 GA., 1 3/4" LONG TABLE R602.3(1) FASTENER SCHEDULE -CRC 2022 BLOCKING BETWEEN RAFTERS OR TRUSS NOT AT THE WALL TOP PLATES, TO RAFTER OR TRUSS END NAIL FLAT BLOCKING TO TRUSS AND WEB FILLER CEILING JOISTS TO TOP PLATE 4-8D BOX (2-1/2" X 0.113"); OR 3-8D COMMON (2-1/2" X 0.131"); OR 3-8D BOX(3" X 0.128"); OR 3-3" X 0.131" NAILS CEILING JOIST NOT ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITIONS [SEE SECTIONS R802.5.2 AND TABLE R802.5.2(1)] FACE NAIL 4-10D BOX (3" X 0.128"); OR 3-16D COMMON (3 1/2" X 0.162");OR CEILING JOIST ATTACHED TO PARALLEL RAFTER (HEEL JOINT) [SEE SECTIONS R802.5.2 AND TABLE R802.5.2(1)] 4 FACE NAILTABLE R802.5.2(1) COLLAR TIE TO RAFTER, FACE NAIL5 FACE NAIL EACH RAFTER 4-10D BOX (3" X 0.128"); OR 3-10D COMMON (3" X 0.148"); OR 4-3" X 0.131" NAILS RAFTER OR ROOF TRUSS TO PLATE6 2 TOE NAILS ON ONE SIDE AND 1 TOE NAIL ON OPPOSITE SIDE OF EACH RAFTER OR TRUSS 3-16D BOX NAILS (3 1/2"X0.135"); OR 3-10D COMMON (3" X 0.148"); OR 4-10D BOX (3" X 0.128"); OR 4-3" X 0.131" NAILS I ROOF RAFTERS TO RIDGE, VALLEY OR HIP RAFTERS OR ROOF RAFTER TO MINIMUM 2" RIDGE BEAM 7 TOE NAIL 4-16D BOX (3 1/2" X 0.135"); OR 3-10D COMMON (3" X 0.148"); OR 4-10D BOX (3" X 0.128"); OR 4-3" X 0.131" NAILS 3-16D BOX 3 1/2" X 0.135"); OR 2-16D COMMON (3 1/2" X 0.162"); OR 3-10D BOX (3" X 0.128"); OR 3-3" X 0.131" NAILS END NAIL ADJACENT FULL-HEIGHT STUD TO END OF HEADER12 4-16D BOX (3 1/2" X 0.135"); OR 3-16D COMMON (3 1/2" X 0.162"); OR 4-10D BOX (3" X 0.128"); OR 4-3" X 0.131" NAILS END NAIL 10D BOX (3" X 0.128"); OR 16" O.C. FACE NAIL 12" O.C. FACE NAIL 16" O.C. FACE NAIL 12" O.C. FACE NAIL 16D COMMON (3 1/2" x 0.162") 16D BOX (3 1/2" X 0.135"); OR 3" X 0.131" NAILS 2-8D COMMON (2 1/2" X 0.131"); OR 2-3" X 0.131" NAILS 6 6 FB 6 12 8D COMMON (2 1/2" X 0.131") NAIL (ROOF); OR RSRS-01; (2 3/8" x 0.113") NAIL (ROOF)B 6 6 F DEFORMED 2 3/8" x 0.113" x 0.266" HEAD (WALL OR SUBFLOOR)6 12 STAPLE GALVANIZED, 1 1/2" LONG; 7/16" OR 1" CROWN OR 1 1/4" SCREWS, TYPE W OR S 1 3/4" x 0.120" GALVANIZED ROOFING NAIL, 7/16" HEAD DIAMETER; OR 1 1/4" LONG 16 GA.; STAPLE GALVANIZED, 1 1/2" LONG; 7/16" OR 1" CROWN OR 1 1/4" SCREWS, TYPE W OR S DEFORMED (2 1/2" X 0.120") NAIL DEFORMED (2" X 0.113"); OR DEFORMED (2 1/2" X 0.120") NAIL DEFORMED (2" X 0.113"); OR DEFORMED (2 1/2" X 0.120") NAIL; OR 9. SCALE: DRAWN BY: DATE: PLAN CHECK DRAWING TITLE: DATEREVISIONS: HN 12-11-2024 AS NOTED 00-00-0000 SHEET NO. OF SHEETS DATE 00-00-2024-------- 00-00-0000 00-00-0000 00-00-0000 00-00-0000 CONSULTANT: 21 0 W . H A R V E Y A V E . U N I T # 2 ( A D U ) , SA N T A A N A , C A 9 2 7 0 7 RESIDENTIAL PROJECT FOR: 210 W. HARVEY AVE.(ADU), SANTA ANA, CA 92707 DE T A C H E D A D U P R O J E C T Exp. date: STATE OF CALIFORNIACIVIL REGISTERED PROFESS IONAL ENGINEER HUE C . LUI C-66754 9/26 1/29/2025 HA NGUYEN - 1/29/2025 GENERAL NOTES 02 11 GN 210 W Harvey Ave Unit #24/22/2025 SHEET INDEX PROJECT DIRECTORY PROPERTY DESCRIPTION VICINITY MAP N.T.S. SCOPE OF WORK PROJECT LOCATION OWNER:JAMES HUYNH (714)791-4750 ZONE:R-1 APN #:410-282-13 STORIES:1 SPRINKLERS: MAIN HOUSE - NO ADU - NO FLOOD ZONE: NO DESIGNER: HA NGUYEN 13172 SANDRA PL., GARDEN GROVE, CA 92843 TEL: (714) 326-3124 CIVIL ENGINEER: SCOPE OF WORK: 1. NEW DETACHED ADU WITH 1 BEDROOM, 1 BATHROOM 2. NEW ADU PORCH 3. PV SYSTEM NOT REQUIRED DUE TO PV EXCEPTION 2 OF 150.1(c)14 1.70KWpv = (572 SQUARE FEET X 0.586) / 1000 (1 DWELLING UNIT + 1.37) (E)MAIN HOUSE 1,429 SQ. FT. __________________________________________________________ __________________________________________________________ (E) GARAGE 466 SQ. FT. (E) FRONT PORCH 102 SQ. FT. (E) TRELLIS PATIO 177 SQ. FT. __________________________________________________________ NEW DETACHED ADU 572 SQ. FT. ADU PORCH 32 SQ. FT. __________________________________________________________ LEGAL JURISDICTION: CITY OF SANTA ANA, CALIFORNIA APPLICABLE CODES: FOR ALL BELOW 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (GBC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA ENERGY CODE (TITLE 24, PART 6) SANTA ANA MUNICIPAL CODE RESIDENTIAL DWELLINGS: CONSTRUCTION TYPE: V-B OCCUPANCY GROUP: R-3/U TOTAL LOT COVERAGE 1,997 SQ. FT. 1429+466+102 __________________________________________________________ LOT COVERAGE %: 29.6 % LOT AREA: 6,740 SQ. FT. TS COVER SHEET, (E)+(N) SITE PLAN GN GENERAL NOTES GR1 GREEN NOTES GR2 GREEN NOTES A1 (E)+(N) FLOOR PLAN, ELEVATIONS A2 ELECTRICAL PLAN S1 FOUNDATION & FRAMING PLAN, SECTION D1 DETAILS T24 TITLE 24 T24 TITLE 24 HUE C. LUI C -66754 10732 LA BATISTA AVE. FOUNTAIN VALLEY, CA 92708 TEL: (714) 679-6472 .4 MILES FROM BUS ID:6539 W MACARTHUR BLVD. E DYER RD. W WARNER AVE. S B R I S T O L S T . S F L O W E R S T . MA I N S T . 55 FWY PROJECT SITE 210 W HARVEY AVE. ENERGY CONSULTANT: ALBERT LUU 10732 LA BATISTA AVE. FOUNTAIN VALLEY, CA 92708 TEL: (714) 679-6472 PR O P E R T Y L I N E 9 1 . 9 8 ' PROPERTY LINE 43.83' PROPERTY LINE 60.54" PRO P E R T Y L I N E 1 0 9 . 8 2 ' PROPERTY LINE 40.95' (E)SITE/ROOF PLAN SCALE: 1/8" = 1'-0" 210 W. HARVEY AVE. ℄ PR O P E R T Y L I N E 9 1 . 9 8 ' PROPERTY LINE 4 3 . 8 3 ' PROPERTY LI N E 6 0 . 5 4 " PR O P E R T Y LINE 1 0 9 . 82' PROPERTY LINE 40.95' (N)SITE/ROOF PLAN SCALE: 1/8" = 1'-0" 210 W. HARVEY AVE. ℄ 12'-9" 27 ' - 1 " 5'-0" 25'-0" 10 ' - 0 " 4'-6" 21' -0" SL O P E 4. 5 : 1 2 SL O P E 4. 5 : 1 2 (E)MAIN HOUSE SLOPE 4.5:12 SLOPE 4.5:12 (E)GARAGE (E ) T R E L L I S P A T I O (E)PORCH SL O P E 4. 5 : 1 2 SL O P E 4. 5 : 1 2 (E)MAIN HOUSE SLOPE 4.5:12 SLOPE 4.5:12 (E)GARAGE (E ) T R E L L I S P A T I O (E)PORCH SLOPE 4.5:12 SLOPE 4.5:12 (N) ADU COND. COND. (E) MAIN HOUSE PANEL (E) GAS METER (FIELD VERIFY) 7'-10" 14'-10" 19 ' - 6 " 20 ' - 7 " 8'-7" 35'-5" 20 ' - 1 1 " 21 ' - 5 " 7'-10" 14'-10" 19 ' - 6 " 20 ' - 7 " 8'-7" 20 ' - 1 1 " 21 ' - 5 " (E ) 6 ' - 0 " B L O C K W A L L (E)6'-0" BLOCK WALL (E)6'-0" BLOCK W A L (E)6 ' -0" BLO C K WAL L 5'-0"EASEMENT 5'-0"EASEMEN T (E) GAS METER (FIELD VERIFY) (N) ADU ELEC PANEL 200 AMP (E ) 6 ' - 0 " B L O C K W A L L (E)6'-0" BLOCK WALL (E)6'-0" BLOCK WAL (E) 6 ' -0" BLO C K WAL L COND. (E) WATER METER (FIELD VERIFY) (E) WATER METER (FIELD VERIFY) FORTNIGHT LILY 1 GALLON TEXAS PRIVET 5 GALLON SPREADING SUNSHINE LANTANA 5 GALLON (E) 24-INCH BOX 3' - 0 " 10'-6" (E) 24-INCH BOX 6' -3 " (E) MAIN HOUSE PANEL UPGRADE TO DUAL 400 AMP METER (N ) 3 " S E W E R L I N E (N)1"WATER LINE (N) 2"UNDERGROUND CONDUIT (E ) 4 " S E W E R L I N E 2% 9' -8 " 5'-1 " 3'-6" P.O.C. P.O.C. CO (N) ESS 5% SLOPE 5% S L O P E 5% S L O P E 5% SLOPE 5% S L O P E 2% S L O P E 2% S L O P E 2% SLOP E 2% SLOPE 2% SLOPE 5% SLOPE 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 08 D1 08 D1 08 D1 NEW CLASS 'A' MIN. TILE ROOF(9.0PSF) (ESR 1017) LOT SHALL BE GRADED TO DRAIN SURGACE WATER AWAY FROM THE FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6" WITHIN THE FIRST 10FT. (5% SLOPE). WHERE LOT LINES, WALLS, SLOPES OR OTHER PHYSICAL BARRIER PROHIBIT 6" OF FALL WITHIN 10FT. DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. (CRC R401.3) LEGEND EXISTING AREA NEW PROPOSED AREA NOTE: THE ADU SF / SFD SF RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN “SFR SF” OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN “SFR SF” OF THE EXISTING RESIDENCE. *ADU 572 SF / SFD 1,429 SF SCALE: DRAWN BY: DATE: PLAN CHECK DRAWING TITLE: DATEREVISIONS: HN 12-11-2024 AS NOTED 00-00-0000 SHEET NO. OF SHEETS DATE 00-00-2024-------- 00-00-0000 00-00-0000 00-00-0000 00-00-0000 CONSULTANT: 21 0 W . H A R V E Y A V E . U N I T # 2 ( A D U ) , SA N T A A N A , C A 9 2 7 0 7 RESIDENTIAL PROJECT FOR: 210 W. HARVEY AVE.(ADU), SANTA ANA, CA 92707 DE T A C H E D A D U P R O J E C T Exp. date: STATE OF CALIFORNIACIVIL REGISTERED PROFESS IONALENGINEER HUE C .LUI C-66754 9/26 1/29/2025 HA NGUYEN - 1/29/2025 (E)+(N) SITE PLAN, GENERAL DATA 01 10 TS DETACHED ADU 210 W. HARVEY AVE. UNIT #2(ADU) SANTA ANA, CA 92707 Bldg #101121971 APPROVALS: PLNG - C. Santana BLDG - CSG POLICE - B. Martin PUBLIC WORKS - Y. Soto 210 W Harvey Ave Unit #24/22/2025 (E) FLOOR PLAN SCALE: 1/4" = 1'-0" NEW ADU FLOOR PLAN SCALE: 1/4" = 1'-0" 12'-9" 27 ' - 1 " 5'-0" 25'-0" 10 ' - 0 " W/D WH PANTRY DW 16 ' - 4 " 9' - 6 " 5' - 6 " 13'-0"2'-1"8'-3" 21 ' - 0 " (E) BEDROOM #1 (E) LIVING ROOM (E) BEDROOM #2 (E) BEDROOM #3 (E) BEDROOM #4 (E) KITCHEN (E) BATH (E) BATH (E) GARAGE (N) ADU ELEC PANEL 200 AMP COND. COND. (E) MAIN HOUSE PANEL UPGRADE TO DUAL 400 AMP METER (E) GAS METER (FIELD VERIFY) 24 ' - 6 " 19'-0" 17 ' - 6 " 25'-2" 37 ' - 3 " 19'-5"18'-11" 4'-8" 24 ' - 1 1 " 7'-0" 5'-10" (N) KITCHEN (N) 9'-0" CL. HT. (N) BEDROOM #1 (N) 9'-0" CL. HT. (N) LIVING ROOM (N) 9'-0" CL. HT. (N) BATH (N) 9'-0" CL. HT. (E) TRELLIS PATIO (N) 2'0"X2'0" SLD OBS TEMP WD (N) 4'0"X4'0" SLD WD (N) 5'0"X4'0" SLD TEMP. WD (N ) 4 ' 0 " X 4 ' 0 " S L D W D (N ) 3 ' 0 " X 3 ' 0 " S L D W D (N ) 3 ' 0 " X 6 ' 8 " E N T R Y D R . (N) 2'6"X6'8" LOUVER DR. (N) PORCH (N) 9'-0" CL. HT. 3' - 0 " 10'-6" 30"MIN 2'-6" 3'-4" 3' - 6 " (N) 3'0"X8'0" DR. (N ) 3 ' 0 " X 8 ' 0 " D R . R311.3.1 (N) CONC. LANDING LA N D I N G 2% S L O P E 1/2" (N) ESS 2'-0"2'-7" 10 " 1 H O U R R A T E D W A L L - S E E D 1 # 8 1 H O U R R A T E D W A L L - S E E D E T A I L # 8 TEMP. GLASS FOR DOOR/ENCLOSURE FIBERGLASS OPAQUE DOOR S1 A T.O. FLOOR T.O. PLATE 9' - 0 " T.O. F. GRADE 8" SOUTH ELEVATION SCALE: 1/4" = 1'-0" 14 ' - 1 0 " 124.5 NOTE: ALL EXTERIOR FINISH OF ADU WILL MATCH EXISTING HOUSE. STUCCO,WINDOWS, DOORS, TRIMS, MULLIONS AND ROOF WILL MATCH BETWEEN (E) DWELLING HOUSE AND (N) ADU. NEW CLASS 'A' MIN. TILE ROOF(9.0PSF) (ESR 1900) OVER 2 LAYER OF #15 FELT PER SEC. R905 INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURE'S SPECIFICATIONS TYP. AND CITY OF SANTA ANA. ROOF MATERIAL OF THE ADDITION WILL MATCH THE COLOR AND MATERIAL OF THE EXISTING. WOOD TRIM (N) SIDE VENT PROVIDE 2 LAYERS OF GRADE D PAPER OVER ALL WOOD BASE SHEATHING 14 ' - 1 0 " EAST ELEVATION SCALE: 1/4" = 1'-0" T.O. FLOOR T.O. PLATE 9' - 0 " T.O. F. GRADE 8" 124.5 NOTE: ALL EXTERIOR FINISH OF ADU WILL MATCH EXISTING HOUSE. STUCCO,WINDOWS, DOORS, TRIMS, MULLIONS AND ROOF WILL MATCH BETWEEN (E) DWELLING HOUSE AND (N) ADU. NEW CLASS 'A' MIN. TILE ROOF(9.0PSF) (ESR 1900) OVER 2 LAYER OF #15 FELT PER SEC. R905 INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURE'S SPECIFICATIONS TYP. AND CITY OF SANTA ANA. ROOF MATERIAL OF THE ADDITION WILL MATCH THE COLOR AND MATERIAL OF THE EXISTING. WOOD TRIM PROVIDE 2 LAYERS OF GRADE D PAPER OVER ALL WOOD BASE SHEATHING NORTH ELEVATION SCALE: 1/4" = 1'-0" 14 ' - 1 0 " T.O. FLOOR T.O. PLATE 9' - 0 " T.O. F. GRADE 8" 124.5 NOTE: ALL EXTERIOR FINISH OF ADU WILL MATCH EXISTING HOUSE. STUCCO,WINDOWS, DOORS, TRIMS, MULLIONS AND ROOF WILL MATCH BETWEEN (E) DWELLING HOUSE AND (N) ADU. NEW CLASS 'A' MIN. TILE ROOF(9.0PSF) (ESR 1900) OVER 2 LAYER OF #15 FELT PER SEC. R905 INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURE'S SPECIFICATIONS TYP. AND CITY OF SANTA ANA. ROOF MATERIAL OF THE ADDITION WILL MATCH THE COLOR AND MATERIAL OF THE EXISTING. WOOD TRIM WOOD BEAM DECOR WOOD TRIM PROVIDE 2 LAYERS OF GRADE D PAPER OVER ALL WOOD BASE SHEATHING THE BUILDING SHALL HAVE ADDRESS NUMBERS PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. NUMBERS SHALL CONTRAST WITH BACKGROUND, BE ARABIC OR ALPHABETICAL LETTERS AND BE A MINIMUM OF 4 ” HIGH WITH A MINIMUM STROKE OF ½”. (R319.1) 210 UNIT #2 WEST ELEVATION SCALE: 1/4" = 1'-0" 14 ' - 1 0 " T.O. FLOOR T.O. PLATE 9' - 0 " T.O. F. GRADE 8" 124.5 NOTE: ALL EXTERIOR FINISH OF ADU WILL MATCH EXISTING HOUSE. STUCCO,WINDOWS, DOORS, TRIMS, MULLIONS AND ROOF WILL MATCH BETWEEN (E) DWELLING HOUSE AND (N) ADU. NEW CLASS 'A' MIN. TILE ROOF(9.0PSF) (ESR 1900) OVER 2 LAYER OF #15 FELT PER SEC. R905 INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURE'S SPECIFICATIONS TYP. AND CITY OF SANTA ANA. ROOF MATERIAL OF THE ADDITION WILL MATCH THE COLOR AND MATERIAL OF THE EXISTING. WOOD TRIM PROVIDE 2 LAYERS OF GRADE D PAPER OVER ALL WOOD BASE SHEATHING LEGEND EXISTING WALL NEW WALL NO.SIZE TYPE MATERIAL GLAZING W I N D O W / D O O R S C H E D U L E 3'-0"X3'-0"SLIDING, W/ GRID VINYL DUAL GLAZED 5'-0"X4'-0" 3'-0"X6'-8"ENTRY DOOR FIBERGLASS VINYL DUAL GLAZED 4'-0"X4'-0"SLIDING, W/ GRID VINYL DUAL GLAZED 2'-0"X2'-0"SLIDING, OBS, TEMP, W/ GRID VINYL DUAL GLAZED SLIDING, W/ GRID 2'-6"X6'-8"LOUVER DOOR METAL U FACTOR = .30 SHGC = .23 (N) ATTIC VENTILATION-ADU: REQUIRED : 572 SF. / 150 SF. = 3.81 SF. VENT. PROVIDED : 2 - 24" DORMER VENTS EACH VENT = 1.57 SF X 2 = 3.14 SF. VENTILATION PROVIDED : 1- 12"X24" SIDE VENT EACH VENT = 2 SF X 1 = 2 SF. VENTILATION TOTAL = 5.14 SF VENTILATION NOTES: 1. AT BEDROOMS PROVIDE ONE OPENABLE ESCAPE WINDOW OR DOOR MEETING ALL OF THE FOLLOWING: A. AN OPENABLE AREA OF NOT LESS THAN 5.7 SQ. FT. (5.0 SF. AT GRADE LEVEL) B. A MINIMUM CLEAR 24 INCH HEIGHT AND 20 INCH WIDTH C. CLEAR OPENING NOT OVER 44 INCHES ABOVE THE FLOOR. CBC 1026.2 2.SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUB WITH SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 6 FEET ABOVE FLOOR. (R307.2) 3.NONASBESTOS FIBER-CEMENT BACKER BOARDS, NONASBESTOS FIBER-MAT REINFORCED CEMENTITIOUS BACKER UNITS, GLASS MAT GYPSUM BACKING PANELS OR FIBER-REINFORCED GYPSUM PANELS SHALL BE USED AS A BACKER FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER AREAS. (R702.4.2 ) 3. ANTI-SCALDING SHOWER AND TUB-SHOWER VALVES REQUIRED. 4. ALL NEW WINDOWS INCLUDING: U-FACTORS = 0.30 & SHGC = 0.23 SCALE: DRAWN BY: DATE: PLAN CHECK DRAWING TITLE: DATEREVISIONS: HN 12-11-2024 AS NOTED 00-00-0000 SHEET NO. OF SHEETS DATE 00-00-2024-------- 00-00-0000 00-00-0000 00-00-0000 00-00-0000 CONSULTANT: 21 0 W . H A R V E Y A V E . U N I T # 2 ( A D U ) , SA N T A A N A , C A 9 2 7 0 7 RESIDENTIAL PROJECT FOR: 210 W. HARVEY AVE.(ADU), SANTA ANA, CA 92707 DE T A C H E D A D U P R O J E C T Exp. date: STATE OF CALIFORNIACIVIL REGISTERED PROFESS IONAL ENGINEER HUE C . LUI C-66754 9/26 1/29/2025 HA NGUYEN - 1/29/2025 EXISTING & NEW FLOOR PLAN 05 11 A1 210 W Harvey Ave Unit #24/22/2025 DRAG CONNECTION N.T.S. SIMP. "MSTC40" STRAP U.N.O FLUSH BEAM PER PLAN DOUBLE TOP PLATES 4X POST 4X POST 3 #4 BARS EA WAY SIMPSON BASE CAP CCB CONC. SLAB 2500 PSI CONCRETE (SEE PLAN) (SEE PLAN) 3" F.A.U IN ATTIC N.T.S. 30" M I N . F.A . U . LIGHTING FIXTURE CONTROLLED BY A SWITCH LOCATED BY ATTIC ACCESS F.A.U SHALL BE LISTED FOR INSTALLATION IN ATTIC AND ON COMBUSTABLE FLOORING CLEARANCES SHALL BE AS SPECIFIED IN THE LISTING 5 /8" CDX X24" MIN. WIDE PLYWD PASSSAGEWAY 20' MAX TRAVEL DISTANCE 30" SQ. VERIFY 22"X30" W/ F.A.U MANUF. ATTIC ACCESS 5/8" CDX PLYWD LEVEL WORKING PLATFORM FOR THE ENTIRE LENGTH OF UNIT LIGHT SWITCH ELECTRICAL OUTLET NOTE: PASSAGEWAY TO THE MECHANICAL EQUIPMENT IN THE ATTIC SHALL BE UNOBSTRUCTED AND HAVE CONTINUOUS SOLID FLOORING NOT LESS THAN 24" WIDE, NOT MORE THAN 20' IN LENGTH THROUGH THE ATTIC. BEAM. TO POST CONN. N.T.S. WD POST SIMPSON CAP (PER PLAN) WD BEAM SIMPSON "MST" RIDGE BEAM N.T.S RIDGE BOARD (SEE FRAMING)2X RR @ 16" O.C. (SEE PLANS) E.N. ROOF SHEATHING LSTA24 @ 48" O.C. D1 12 POST PAD DETAIL (TYP.) N.T.S. 16 04 12 13 07 03 19 050102 08 09 14 15 20 06 1110 21 22 1817 SIMSPON HOLDOWN SIMPSON HDU (PER PLAN) W/1/4"X3" SCREWS (ICC ESR-2330) 12" 5" NEW SHEAR WALL (SEE PLANS) CONC. FOOTING F.G F.F SSTB16 5/8"X12-5/8" LE. PER ESR-2611 3" MIN. 24" 2X STUDS @ 16" O.C./ 4X4 OR 2-2x4 HDU2-8D82.5 HDU4-8D82.5 HDU5-8D82.5 HDU8-8D82.5 SCREWS TO POST 1/4"X2.5" 1/4"X2.5" 1/4"X2.5" 1/4"X2.5" ANCHOR BOLT NUTS/WASHERS 5/8" 5/8" 5/8" 7/8" NOTE: 1. ALL HOLDOWN ANCHORS MUST BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION. 2. DEEPEN FOOTING AS REQUIRE TO OBTAIN ANCHORS EMBEDMENT AND CONCRETE COVER. P.T.D.F SILL PLATE (PER PLAN) HDU-SDS2.5 @ FOOTING N.T.S. FLOOR/ROOF SHEATING (4'X8' OSB. SHEATING) FLOOR OR ROOF JOIST PANEL FIELD NAILING DIAPHRAGM BOUNDARY NAILING PANEL EDGE NAILING BLOCKING @ PANEL EDGES NOT REQUIRED @ ROOF OR IF T&G SHEATING IS UDED ROOF SHEATHING N.T.S. 2X RAFTER @ 16" O.C. TYP. 4X HEADER SEE PLAN 60° DOUBLE TOP PLATE CRIPPLE STUDS TRIMMER STUDS TO SUPPORT HEADER WALL FRAMING N.T.S. 3-16D NAILS FOR 2X TRIMMER (2-2X TRIMMER AT OPENING WIDER THAN 6'-0") 4-16D NAILS FOR 4X HEADER ROUGH SILL CRIPPLE 2 X 4 SOLE PLATE INTERIOR WALL TO FLR N.T.S. 2X4 STUDS @ 16" O.C. SHOT PIN @ 24" O.C. ICC 1799 2X RR @ 16" O.C. 2X 16D NAILS EA SIDE 2X4 STUDS @ 16" O.C. INTERIOR PAD FOOTING N.T.S. EXTERIOR FOOTING N.T.S. 12" 24 " 5" CONC. SLAB W/ #4 REBAR @18" E.W. 2X4 P.T.D.F. MUD SILL W/ 5/8 Ø A.B. X 10" LONG W/ 3" X 3" X .229" WASHER 7" INTO CONC. 12" FROM CORNERS AND 48" O.C. MAX. 5" 2X STUDS @ 16" O.C. 3" CLR 8"MIN GRD. R-15 4" ABOVE EARTH OR 2" ABOVE PAVED AREAS 26GA SCREED STUCCO FINISH CEMENT PLASTER ON MEATAL LATH SHALL HAVE AT LEAST 7/8" THICKNESS MIXED 1:2 FOR SCRATCH COAT AND 1:3 BROWN COAT BY WEIGHT, CEMENT TO SAND AGGREGATE. 2-#5 CONT. 3" FROM TOP & BOTTOM TYP. ALL F'TG'S. 10 MIL VISQUEEN 4" THK (MIN) BASE OF 1 2" CLEAN AGGREGATE 24" 24" @ 36" O.C. 24 12"MIN FOR ADU 5" CONC. SLAB W/ #3 REBAR @18" E.W. SIMPSON POST CAP N.T.S. SIMPSON LU 4X POST 4X HDR SIMPSON EPC CARRY HDR 4X POST (SEE PLAN) 3- #4 BARS EA WAY SIMPSON BASE CAP PBS 3" MIN. 6" 3" CONC. SLAB OR 2" ASPHALTIC CONC. SLAB (SEE PLAN) CJ TO BEAM N.T.S. LU HANGER LU HANGER (N) FLUSH BEAM (SEE PLAN) (WHERE OCCURS) 2X CJ @ 16" O.C. (SEE PLANS) 2X CJ @ 16" O.C. (SEE PLANS) 5-16D NAILS EN. 2 X BLKG. A35 @ 32" O.C. ROOF SHTG.STARTER BOARD 5 1 / 2 " 2X RR @ 16" O.C. (SEE PLANS) CEMENT PLASTER ON METAL LATH SHALL HAVE AT LEAST 7 8" THICKNESS MIXED 1:2 FOR SCRATCH COAT AND 1:3 BROWN COAT BY WEIGHT, CEMENT TO SAND AGGREGATE. STUCCO FINISH 1 HOUR RATED EAVE DETAIL N.T.S. (N) 2X6 CJ @ 16" O.C. (SEE PLAN) 7-16D NAILS R-15 EN. 2X4 STUDS @ 16" O.C. 2 X BLKG. A35 @ 32" O.C. 2X CJ @ 16" O.C. (SEE PLANS) (WHERE OCCURS) ROOF SHTG.STARTER BOARD NEW SHEAR WALL (SEE PLANS) 2X RR @ 16" O.C. (SEE PLANS) R-38 1 HOUR FIRE N.T.S. STUCCO FINISH CEMENT PLASTER ON METAL LATH SHALL HAVE AT LEAST 7 8" THICKNESS MIXED 1:2 FOR SCRATCH COAT AND 1:3 BROWN COAT BY WEIGHT, CEMENT TO SAND AGGREGATE. EN 2X BLOCKING /OR JOIST 2X4 STUDS @ 16" OC R-15 INSULATION 2X CEILING JTS @ 16" 0C R-38 INSULATION 2X RAFTERS @16" OC 2X4 FLATS @ 36" OC ROOF SHTG.STARTER BOARD A35 @ 32" O.C. NEW SHEAR WALL (SEE PLANS) W/ A35 @ 32" O.C. DBL TP EN 5 8"TYPE X DRYWALL IF LESS THAN 5'-0" FROM P.L. STUCCO FINISH CEMENT PLASTER ON METAL LATH SHALL HAVE AT LEAST 7 8" THICKNESS MIXED 1:2 FOR SCRATCH COAT AND 1:3 BROWN COAT BY WEIGHT, CEMENT TO SAND AGGREGATE. 1 HOUR FIRE N.T.S. R-5 R-5 5 8"TYPE X DRYWALL IF LESS THAN 5'-0" FROM P.L. DBL BLOCKING OPENING (SEE PLAN)2-16D NAILS EA SIDE ATTIC ACCESS FRAMING N.T.S. 23 2X4 @ 16" OC. ST6224 STRAP @ 32" OC. 2X4 BRACE @ 32" OC. EN. (E)2X4 STUDS @ 16" O.C. (E)2X CJ @ 16" O.C. ROOF SHTG.STARTER BOARD (E)2X RR @ 16" O.C. 1 HOUR OVERHANG N.T.S. (N)STUCCO FINISH CEMENT PLASTER ON METAL LATH SHALL HAVE AT LEAST 7 8" THICKNESS MIXED 1:2 FOR SCRATCH COAT AND 1:3 BROWN COAT BY WEIGHT, CEMENT TO SAND AGGREGATE. (E) DRYWALL (E)STUCCO FINISH H2.5@48" O.C. H2.5@48" O.C.SCALE: DRAWN BY: DATE: PLAN CHECK DRAWING TITLE: DATEREVISIONS: HN 12-11-2024 AS NOTED 00-00-0000 SHEET NO. OF SHEETS DATE 00-00-2024-------- 00-00-0000 00-00-0000 00-00-0000 00-00-0000 CONSULTANT: 21 0 W . H A R V E Y A V E . U N I T # 2 ( A D U ) , SA N T A A N A , C A 9 2 7 0 7 RESIDENTIAL PROJECT FOR: 210 W. HARVEY AVE.(ADU), SANTA ANA, CA 92707 DE T A C H E D A D U P R O J E C T Exp. date: STATE OF CALIFORNIACIVIL REGISTERED PROFESS IONAL ENGINEER HUE C . LUI C-66754 9/26 1/29/2025 HA NGUYEN - 1/29/2025 DETAILS 08 11 D1 210 W Harvey Ave Unit #24/22/2025 LEGEND SHEAR WALL EXISTING WALL NEW FOUNDATION NOTES: 5" THICK CONC. SLAB FLOOR, 4,500 PSI. @ 28 DAYS, TYPE V CEMENT W/ #4 @ 18" O.C. EA WAY, OVER 10 MIL VISQUEEN OVER 4" BASE 1 2" OR LARGER CLEAN AGGREGATE 12"Wx24"D CONT. FTG., W/ 2#5 T&B (N) PAD FOOTING 30"SQ X 24"DEEP W/ 3-#4 EA WAY (N) PAD FOOTING 24"SQ X 24"DEEP W/ 3-#4 EA WAY 1 2 FOUNDATION ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL PLATE SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. *CONCRETE IN CONTACT WITH THE SOIL SHALL HAVE AN MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 4,500 P.S.I. WATER CEMENT RATIO OF 0.45 AND TYPE V CEMENT UNLESS A SOIL REPORT RECOMMENDS OTHERWISE. *ALL SHEAR HARDWARE AND ANCHOR BOLTS WITH NON-STANDARD SPACING ARE TO BE FIXED IN PLACE FOR FOUNDATION INSPECTION. SCARIFY TOP 12 INCHES PRIOR TO TRENCHING FOR THE UTILITY AND/OR FOUNDATION. 90% COMPACTION REPORT IS REQUIRED AT THE TIME OF FOUNDATION INSPECTION. DAMP PROOFING, BASE COURSE AND PRE-SATURATION ARE REQUIRED. NEW WALL 3 4 PANEL THICKNESS PANEL INDEX EDGE NAILING 1 2 3 4 3/8" 24/0 8 D @ 6" 1/2"1/2"1/2" 24/0 24/0 24/0 FIELD NAILING TOP PLATE 2-2X 2X SILL CON. ANCHOR BOLTS A35 24" @ O.C. RATING SILL PLATE ON WOOD FLR. FOUND. SILL PLATE END POSTS (MIN.) CAPACITY 260 (SHEAR WALL SCHEDULE FOR CRC 2022) (SHEAR WALL #3, #4: W/ 3X STUD, SILL & BLOCK BETWEEN ADJACENT PANELS 1/2" EDGE DISTANCE FOR PLYWOOD BOUNDARY NAILING.) 8 D @ 4" 8 D @ 12" 8 D @ 3"8 D @ 2" 8 D @ 12"8 D @ 12"8 D @ 12" 2-2X 2-2X 2-2X 2X 2X 2X 2X 2X 3X 3X 4X 4X OR DBL 2X 4X OR DBL 3X 4X OR DBL 3X 16 D @ 6" 5/8" D X10" @ 24" 16 D @ 4"40 D @ 4"40 D @ 3" 5/8" D @ 16" 5/8" D @ 12" 5/8" D @ 24" 16" @ O.C.12" @ O.C.9" @ O.C. APA CDX EXPOSURE 1 APA CDX EXPOSURE 1 340 460 600 SHEAR WALL SCHEDULE WHERE PANELS ARE APPLIED ON BOTH FACES OF A SHEARWALL AND NAIL SPACING IS LESS THAN 6 INCHES ON CENTER ON EITHER SIDE, PANEL JOIST SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS. ALTERNATIVELY, THE WIDTH OF THE NAILED FACE OF FRAMING MEMEBERS SHALL BE 3" OR GREATER AT ADJOINING PANEL EDGES AND NAILS AT ALL PANEL EDGES SHALL BE STAGGERED. SHEAR WALL SCHEDULE V = 260 PLF PLYWOOD SHEAR WALL (STRUCT I): 3/8" THK CDX PLYWOOD (ALTER 5/16" THK. OSB PANEL) APA RATED 32/16 INDEX 8D COMMON NAILS @ 6", 12" O.C. 5/8"Ø X 10 AB'S @ 24" O.C. / 3X 3X 0.229 PLATE WASHER 1 NOTE FASTENERS IN PRESSURE-TREATED AND FIRE-RETARDANT, TREATED WOOD SHALL BE OF HOT-DIPPED, ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. ROOF SHEATHING (UNBLOCKED) 1/2" THK CDX PLYWOOD (ALTER 7/16 THICK. OSB) APA RATED STRUCTURAL PANEL 32/16 INDEX, 8 D COMMON NAILS @ 6", 12" O.C. FACE GRAIN PERPENDICULAR TO SUPPORT (TYP.) D1 12 NOTE WOOD FRAMING MEMBERS, INCLUDING WOOD SHEATHING, THAT REST ON FOUNDATION WALL ARE LESS THAN 8" SHALL BE PRESERVATIVE- TREATED WOOD PER CBC 2022. 01 D1 01 D1 01 D1 1 06 D1 2 01 D1 405 D1 19 D1 18 D1 S1 A S1 A FOUNDATION PLAN SCALE: 1/4" = 1'-0" 12'-9" 27 ' - 1 " 25'-0" 10 ' - 0 " 16 ' - 4 " 9' - 6 " 13'-0"2'-1"8'-3" 21' - 0 " (N) KITCHEN (N) 9'-0" CL. HT. (N) BEDROOM #1 (N) 9'-0" CL. HT. (N) LIVING ROOM (N) 9'-0" CL. HT. (N) BATH (N) 9'-0" CL. HT. (N) PORCH (N) 9'-0" CL. HT. 3' - 0 " 10'-6" FRAMING PLAN SCALE: 1/4" = 1'-0" 12'-9" 27 ' - 1 " 25'-0" 10 ' - 0 " 16 ' - 4 " 9' - 6 " 5' - 6 " 13'-0"2'-1"8'-3" 21' - 0 " (N) KITCHEN (N) 9'-0" CL. HT. (N) BEDROOM #1 (N) 9'-0" CL. HT. (N) LIVING ROOM (N) 9'-0" CL. HT. (N) BATH (N) 9'-0" CL. HT. (N) PORCH (N) 9'-0" CL. HT. 3' - 0 " 10'-6" 1L=8' 1 L=2' 1 L=8' 1 L=6'5' - 6 " 3' - 6 " 11'-11" 1 2 B A (N ) H D U 2 03 D1 (N ) H D U 2 03 D1 (N ) H D U 2 (N ) H D U 2 (N ) H D U 2 (N ) H D U 2 03 D1 03 D1 03 D1 03 D1 1 2 B A 1L=8' 1 L=2' 1 L=8' 1 L=6' 1 L=8' (N ) 2 x 8 R I D G E B O A R D (N ) 2 x 8 R I D G E B O A R D (N ) 3 - 1 / 2 " x 1 1 - 7 / 8 " P S L F L U S H B E A M (N ) 4 x 1 0 D F # 1 F L U S H B E A M (N) 4x6 HDR (N) 4x4 HDR (N) 4x4 HDR(N) 4x8 HDR (N ) 4 x 6 H D R (N ) 4 x 4 H D R (N ) 4 x 4 H D R (N) 2x8 R/R @ 16" O.C. (N) 2x8 R/R @ 16" O.C. (N) 2x6 C/J @ 16" O.C. (N) 2x6 C/J @ 16" O.C. (N) 4x10 HDR (N ) 4 x 6 H D R (N ) 4 x 6 H D R 1 2 2 2 3 05 D1 01 D1 02 D1 18 D1 19 D1 07 D1 08 D1 08 D1 08 D1 07 D1 20 D1 11 D1 20 D1 06 D1 10 D1 S1 A S1 A (N) H D U 2 (N) H D U 2 03 D1 (N) ST6224 1 L=8' 22X30 ATTIC 16 D1 BASIS OF DESIGN (CBC 1603): A. ROOF LIVE LOAD = 20 PSF B. ATTIC STORAGE LOAD = N/A C. WIND DESIGN DATA. I. BASIC WIND SPEED = 95 PSF II. WIND EXPOSURE = C D. EARTHQUAKE DESIGN DATA I. MAPPED Ss = 1.277 MAPPED S1 = 0.458 II. SITE CLASS = D III. SESMIC DESIGN CATEGORY = D IV. BASIC SEISMIC-FORCE-RESISTING SYSTEM(S). = PLYWOOD SHEAR WALL V. Cs = 0.21 R = 6.5 VI ANALYSIS PROCEDURE USED. = EQUIVALENT LATERAL FORCE PROCEDURE E. SOIL LOADING BEARING VALUES: 1500 PSF SECTION - A - SCALE: 1/4" = 1'-0" (N) 2X6 RR @ 16" O.C. (TYP.)(N) 2X6 RR @ 16" O.C. (TYP.) (N) 2x6 C/J @16" O.C. (N) BEDROOM #1 (N) R-15 (N) R-15 (N) 2X4 STUD WALL @16" 0.C. (TYP.) (N) 1/2" DRYWALL (N) 2 LAYER OF GRADE D PAPER 7/8" STUCCO (N) R-38 T.O. FLOOR T.O. PLATE 9' - 1 " 14 ' - 1 0 " T.O. ROOF T.O. F. GRADE 8" (N) R-15 (N) 2X4 STUD WALL @16" 0.C. (TYP.) (N) 1/2" DRYWALL (N) 2 LAYER OF GRADE D PAPER 7/8" STUCCO (N) R-38 124.5 (N) 2X8 RIDGE (N) 4x10 DF#1 (N) BATH(N) CL *RADIANT BARRIER REQUIRED SCALE: DRAWN BY: DATE: PLAN CHECK DRAWING TITLE: DATEREVISIONS: HN 12-11-2024 AS NOTED 00-00-0000 SHEET NO. OF SHEETS DATE 00-00-2024-------- 00-00-0000 00-00-0000 00-00-0000 00-00-0000 CONSULTANT: 21 0 W . H A R V E Y A V E . U N I T # 2 ( A D U ) , SA N T A A N A , C A 9 2 7 0 7 RESIDENTIAL PROJECT FOR: 210 W. HARVEY AVE.(ADU), SANTA ANA, CA 92707 DE T A C H E D A D U P R O J E C T Exp. date: STATE OF CALIFORNIACIVIL REGISTERED PROFESS IONAL ENGINEER HUE C . LUI C-66754 9/26 1/29/2025 HA NGUYEN - 1/29/2025 FOUNDATION & FRAMING PLAN, SECTION 07 11 S1 X X X X X 210 W. HARVEY AVE. UNIT #2 JAMES HUYNH (714)791-4750JAN 29, 2025 JAMES HUYNH 210 W Harvey Ave Unit #24/22/2025 SCALE: DRAWN BY: DATE: PLAN CHECK DRAWING TITLE: DATEREVISIONS: HN 12-11-2024 AS NOTED 00-00-0000 SHEET NO. OF SHEETS DATE 00-00-2024-------- 00-00-0000 00-00-0000 00-00-0000 00-00-0000 CONSULTANT: 21 0 W . H A R V E Y A V E . U N I T # 2 ( A D U ) , SA N T A A N A , C A 9 2 7 0 7 RESIDENTIAL PROJECT FOR: 210 W. HARVEY AVE.(ADU), SANTA ANA, CA 92707 DE T A C H E D A D U P R O J E C T Exp. date: STATE OF CALIFORNIACIVIL REGISTERED PROFESS IONAL ENGINEER HUE C . LUI C-66754 9/26 1/29/2025 HA NGUYEN - 1/29/2025 GREEN NOTES 03 11 GR1 210 W Harvey Ave Unit #24/22/2025 SCALE: DRAWN BY: DATE: PLAN CHECK DRAWING TITLE: DATEREVISIONS: HN 12-11-2024 AS NOTED 00-00-0000 SHEET NO. OF SHEETS DATE 00-00-2024-------- 00-00-0000 00-00-0000 00-00-0000 00-00-0000 CONSULTANT: 21 0 W . H A R V E Y A V E . U N I T # 2 ( A D U ) , SA N T A A N A , C A 9 2 7 0 7 RESIDENTIAL PROJECT FOR: 210 W. HARVEY AVE.(ADU), SANTA ANA, CA 92707 DE T A C H E D A D U P R O J E C T Exp. date: STATE OF CALIFORNIACIVIL REGISTERED PROFESS IONAL ENGINEER HUE C . LUI C-66754 9/26 1/29/2025 HA NGUYEN - 1/29/2025 GREEN NOTES 04 11 GR2 210 W Harvey Ave Unit #24/22/2025 SCALE: DRAWN BY: DATE: PLAN CHECK DRAWING TITLE: DATEREVISIONS: HN 12-11-2024 AS NOTED 00-00-0000 SHEET NO. OF SHEETS DATE 00-00-2024-------- 00-00-0000 00-00-0000 00-00-0000 00-00-0000 CONSULTANT: 21 0 W . H A R V E Y A V E . U N I T # 2 ( A D U ) , SA N T A A N A , C A 9 2 7 0 7 RESIDENTIAL PROJECT FOR: 210 W. HARVEY AVE.(ADU), SANTA ANA, CA 92707 DE T A C H E D A D U P R O J E C T Exp. date: STATE OF CALIFORNIACIVIL REGISTERED PROFESS IONAL ENGINEER HUE C . LUI C-66754 9/26 1/29/2025 HA NGUYEN - 1/29/2025 MANDATORY MEASURES 09 11 MM 210 W Harvey Ave Unit #24/22/2025 SCALE: DRAWN BY: DATE: PLAN CHECK DRAWING TITLE: DATEREVISIONS: HN 12-11-2024 AS NOTED 00-00-0000 SHEET NO. OF SHEETS DATE 00-00-2024-------- 00-00-0000 00-00-0000 00-00-0000 00-00-0000 CONSULTANT: 21 0 W . H A R V E Y A V E . U N I T # 2 ( A D U ) , SA N T A A N A , C A 9 2 7 0 7 RESIDENTIAL PROJECT FOR: 210 W. HARVEY AVE.(ADU), SANTA ANA, CA 92707 DE T A C H E D A D U P R O J E C T Exp. date: STATE OF CALIFORNIACIVIL REGISTERED PROFESS IONAL ENGINEER HUE C . LUI C-66754 9/26 1/29/2025 HA NGUYEN - 1/29/2025 TITLE 24 10 11 T24 210 W Harvey Ave Unit #24/22/2025 SCALE: DRAWN BY: DATE: PLAN CHECK DRAWING TITLE: DATEREVISIONS: HN 12-11-2024 AS NOTED 00-00-0000 SHEET NO. OF SHEETS DATE 00-00-2024-------- 00-00-0000 00-00-0000 00-00-0000 00-00-0000 CONSULTANT: 21 0 W . H A R V E Y A V E . U N I T # 2 ( A D U ) , SA N T A A N A , C A 9 2 7 0 7 RESIDENTIAL PROJECT FOR: 210 W. HARVEY AVE.(ADU), SANTA ANA, CA 92707 DE T A C H E D A D U P R O J E C T Exp. date: STATE OF CALIFORNIACIVIL REGISTERED PROFESS IONAL ENGINEER HUE C . LUI C-66754 9/26 1/29/2025 HA NGUYEN - 1/29/2025 TITLE 24 11 11 T24 210 W Harvey Ave Unit #24/22/2025 1. PROVIDE APPROVED SMOKE ALARMS, SMOKE ALARMS SHALL BE INTERCONNECTED SUCH THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. 2. SMOKE DETECTORS SHALL BE "HARD WIRED" AND SHALL BE EQUIPPED WITH BATTERY BACK-UP @ ALL NEW BEDROOMS. 3.THE SMOKE ALARMS SHALL BE INTERCONNECTED. (R314.4) 4. FOR SINGLE-FAMILY DWELLINGS AND DUPLEXES ARE NOT CHECKED FOR PLUMBING, MECHANICAL AND ELECTRICAL CODE COMPLIANCE. THESE DISCIPLINES ARE SUBJECT TO FIELD INSPECTION. 5. THE RESIDENCE SHALL CONFORM TO THE STATE ENERGY STANDARDS. NOTES: LEGEND 110 v DUPLEX ELEC. OUTLET WATER PROOF HOSE BIBB W/ ANTI-SIPHONE WALL MOUNTED LIGHT CEILING MOUNTED LIGHT 6" LED RECESS LIGHT CEILING FAN SINGLE POLE SWITCH SMOKE DETECTOR BATTERY (INTER-CONNECTED) S HB GROUND FAULT INTERUPTED CIRCUIT AFCI ARC FAULT CIRCUIT INTERRUPTER GFI EXHAUST FAN (100 CFM) W/ HUMIDITY CONTROL (MAX 3 SONE) DIMMER SWITCH VACANCY SENSORS S S D vs 110 VOLT WEATHER PROOF OUTLET, GFIGFI/ WP SD 3-WAY SWITCHS3 CARBON MONOXIDE DETECTORS (CRC R315) SECTIONS R315.1 & R315.2 CO 1. ALL EXISTING APPROVED SMOKE ALARMS & CARBON MONOXIDE ALARM IN EACH UNITS. IF NOT PLEASE PROVIDE & SHALL COMPLY WITH THE STATE ENERGY STANDARDS & CITY MUNICIPAL CODE STANDARDS. (FIELD VERIFY AT LOCATION) 2.ALL RECEPTACLE OUTLETS SHALL BE LISTED TAMPER-RESISTANT RECEPTACLE PER CEC 406.12 3.BATHROOM RECEPTACLES SHALL BE SERVED BY A DEDICATED 20 AMP CIRCUIT PER CEC 210.52(D) NOTES: LEGEND EXISTING WALL NEW WALL FOR ALTERATIONS, REPAIRS OR ADDITIONS EXCEEDING $1000, EXISTING DWELLINGS OR SLEEPING UNITS THAT HAVE ATTACHED GARAGES OR FUEL-BURNING APPLIANCES SHALL BE PROVIDED WITH A CARBON MONOXIDE ALARM. (R315.1 CRC). * ALARMS WILL BE BATTERY OPERATED. * ALARMS SHALL BE LOCATED OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. *LISTING & APPROVAL BY THE OFFICE OF THE STATE FIRE MARSHAL FOR COMBINED CARBON MONOXIDE & SMOKE ALARMS ARE ALLOWED. 1. WALLS 2 FT. OR GREATER SHALL HAVE AN OUTLET. OUTLETS SHALL BE SPACED MAX. 12 FT. APART, AND A MAXIMUM OF 6 FT. FROM END OF WALLS OR OPENING (CEC 210-52A) 2. ALL RECEPTACLE OUTLETS SHALL BE LISTED TAMPER-RESISTAND RECEPTACLE PER CEC 406.11. 3. BATHROOM RECEPTACLES SHALL BE SERVED BY A DEDICATED 20 AMP CIRCUIT PER CEC 210-52(D). ALL NEW CONSTRUCTION, INTERIOR OR EXTERIOR ALL NEW CONSTRUCTION, INTERIOR OR EXTERIOR ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A PERMIT AND HAVING A VALUATION IN EXCESS OF $1,000, AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES SHALL BE PROVIDED WITH CARBON MONOXIDE ALARMS (CRCR315) - CARBON MONOXIDE ALARMS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS OBTAINED. CARBON MONOXIDE ALARMS REQUIRED BY SECTIONS R315.1 AND R315.2 SHALL BE INSTALLED. REVISE DRAWINGS TO SHOW COMPLIANCE. - OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S). - ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. - WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITHIN THE DWELLING UNIT OR WITHIN A SLEEPING UNIT THE ALARM SHALL BE INTERCONNECTED IN A MANNER THAT ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. EXCEPTION: INTERCONNECTION IS NOT REQUIRED IN EXISTING DWELLING UNITS WHERE REPAIRS DO NOT RESULT IN THE REMOVAL OF WALL AND CEILING FINISHED, THERE IS NO ACCESS BY MEANS OF ATTIC, BASEMENT OR CRAWL SPACE, AND NO PREVIOUS METHOD FOR INTERCONNECTION EXISTED. 1. PROVIDE A MINIMUM OF 2-20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN COUNTER TOPS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE BALANCED. CEC 210-52(B)(2). 2. PROVIDE A MINIMUM OF 1-20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. CEC 210-23(a) 3.ALL INSTALLED LUMINAIRES MUST BE HIGH EFFICACY IN ACCORDANCE WITH TABLE 150.0A. 4.EXHAUST FANS MUST BE SWITCHED SEPARATELY FROM LIGHTING SYSTEMS. 5.IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES MUST BE CONTROLLED BY A VACANCY SENSOR. 1.KITCHEN RANGE HOOD (NEW CONSTRUCTION CA ENERGY CODE 150.0(o)2.B.) SHALL BE FIELD VERIFIED IN ACCORDANCE WITH THE PROCEDURES IN REFERENCE RESIDENTIAL APPENDIX RA3.7.4.3 TO CONFIRM TO THE MODEL IS RATED BY HVI TO COMPLY WITH THE FOLLOWING REQUIREMENTS: A.THE MINIMUM VENTILATION RATE AS SPECIFIED IN SECTION 5 OF ASHRAE 62.2. B.THE MAXIMUM SOUND RATING AS SPECIFIED IN SECTION 7,2 OF ASHRAE 62.2. 2.DUCTS USED FOR DOMESTIC KITCHEN RANGE OR COOKTOP VENTILATION SHALL BE OF METAL AND SHALL HAVE SMOOTH INTERIOR SURFACES. (504.3) EXCEPTION: DUCTS FOR DOMESTIC KITCHEN DOWNDRAFT GRILL-RANGE VENTILATION INSTALLED UNDER A CONCRETE SLAB FLOOR SHALL BE PERMITTED TO BE OF APPROVED SCHEDULE 40 PVC PROVIDED IN COMPLIANCE WITH CMC 504.3. 3.CONDENSATE WASTE SHALL BE COLLECTED AND DISCHARGED TO AN APPROVED PLUMBING FIXTURE OR DISPOSAL AREA. CONDENSATE OR WASTEWATER SHALL NO DRAIN OVER A PUBLIC WAY. (310.1) *MECHANICAL UNIT FILTERS MUST BE MERV-13 OR BETTER. (150.0(m)12C) NOTES: MECH. NOTES: ADDITIONAL ELECTRICAL NOTES: NEW CONSTRUCTION (150.0(N). WATER HEATING SYSTEMS USING GAS OR PROPANE TO SERVE INDIVIDUAL DWELLING UNITS SHALL DESIGNATE A SPACE AT LEAST 2.5 FEET BY 2.5 FEET WIDE AND 7 FEET TALL SUITABLE FOR THE FUTURE INSTALLATION OF A HEAT PUMP WATER HEATER (HPWH) BY MEETING EITHER A OR B BELOW. A.A DEDICATED 125 VOLTS, 20-AMP ELECTRICAL RECEPTACLE THAT IS CONNECTED TO THE ELECTRIC PANEL WITH A 120/240 VOLT 3 CONDUCTOR, 10 AWG COPPER BRANCH CIRCUIT, WITHIN 3 FEET FROM THE WATER HEATER AND ACCESSIBLE TO THE WATER HEATER WITH NO OBSTRUCTIONS; AND B.BOTH ENDS OF THE UNUSED CONDUCTOR SHALL BE LABELED WITH THE WORD “SPARE” AND BE ELECTRICALLY ISOLATED; AND C.A RESERVED SINGLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL ADJACENT TO THE CIRCUIT BREAKER FOR THE BRANCH CIRCUIT ABOVE AND LABEL WITH THE WORDS “FUTURE 240V USE”; AND D.A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF THE INSTALLED WATER HEATER, AND ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE. ENERGY STORAGE SYSTEM (ESS) READY. AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: A.ESS READY INTERCONNECTION EQUIPMENT WITH A MINIMUM BACKED-UP CAPACITY OF 60 AMPS AND A MINIMUM OF FOUR ESS-SUPPLIED BRANCH CIRCUITS, OR B.A DEDICATED RACEWAY FROM THE MAIN SERVICE PANEL TO A PANELBOARD (SUBPANEL) THAT SUPPLIES THE FOLLOWING BRANCH CIRCUITS: REFRIGERATOR, LIGHTING CIRCUIT NEAR PRIMARY EGRESS DOOR, SLEEPING ROOM RECEPTACLE AND ONE ADDITIONAL. THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING OF 225 AMPS. SPACE SHALL BE RESERVED TO ALLOW FUTURE INSTALLATION OF A SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH WITHIN 3 FEET OF THE MAIN PANELBOARD. RACEWAYS SHALL BE INSTALLED BETWEEN THE PANELBOARD AND THE SYSTEM ISOLATION EQUIPMENT TO ALLOW THE CONNECTION OF BACKUP POWER SOURCE. HEAT PUMP SPACE HEATER READY. SYSTEMS USING A GAS OR PROPANE FURNACE SHALL INCLUDE A DEDICATED 240-VOLT BRANCH CIRCUIT WITH 3 FEET OF THE FURNACE. THE BRANCH CIRCUIT SHALL BE RATED AT 30 AMPS MINIMUM. THE MAIN ELECTRICAL SERVICE SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE”. (CALIFORNIA ENERGY CODE 150.0(T)) ELECTRIC COOKTOP READY. SYSTEMS USING A GAS OR PROPANE COOKTOP SHALL INCLUDE A DEDICATED 240-VOLT BRANCH CIRCUIT WITH 3 FEET OF THE COOKTOP. THE BRANCH CIRCUIT SHALL BE RATED AT 50 AMPS MINIMUM. THE MAIN ELECTRICAL SERVICE SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE”. (CALIFORNIA ENERGY CODE 150.0(U)) ELECTRICAL CLOTHES DRYER READY. SYSTEMS USING A GAS OR PROPANE DRYER SHALL INCLUDE A DEDICATED 240-VOLT BRANCH CIRCUIT WITH 3 FEET OF THE CLOTHES DRYER. THE BRANCH CIRCUIT SHALL BE RATED AT 30 AMPS MINIMUM. THE MAIN ELECTRICAL SERVICE SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE”. (CALIFORNIA ENERGY CODE 150.0(V)) 1. AT BEDROOMS PROVIDE ONE OPENABLE ESCAPE WINDOW OR DOOR MEETING ALL OF THE FOLLOWING: A. AN OPENABLE AREA OF NOT LESS THAN 5.7 SQ. FT. (5.0 SF. AT GRADE LEVEL) B. A MINIMUM CLEAR 24 INCH HEIGHT AND 20 INCH WIDTH C. CLEAR OPENING NOT OVER 44 INCHES ABOVE THE FLOOR. CBC 1026.2 2. SHOWERS SHALL BE FINISHED 72" ABOVE DRAIN WITH MATERIALS NOT ADVERSELY AFFECTED BY MOISTURE. 3. ANTI-SCALDING SHOWER AND TUB-SHOWER VALVES REQUIRED. 4.ADDITIONS THAT EXCEED 50% OF EXISTING LIVING FLOOR AREA REQUIRE UNDER GROUNDING OF ALL EXISTING ABOVE GROUND UTILITIES. "PER BUILDING POLICY, WHERE FEASIBLE, AND AS DETERMINED BY THE BUILDING INSPECTOR, ALL ABOVE-GROUND UTILITIES SHALL BE RELOCATED UNDERGROUND." 5.ALL NEW WINDOWS INCLUDING: U-FACTORS = 0.30 & SHGC = 0.23 NOTES: 22X30 ATTIC HB (N)FAU 17 D1 16 D1 AFCI (N) SD WHOLE HOUSE FAN 50 CFM ALL SERVICES SUPPYING DWELLING UNITS SHALL BE PROVIDED A SURGE PROTECTION DEVICE. THE SPD SHALL BE AN INTEGRAL PART OF THE SERVICE EQUIPMENT OR SHALL BE LOCATED IMMEDIATELY ADJACENT THERETO. (CEC 230.667) PAD SUPPORTING CONDENSER SHALL BE A MINIMUM OF 3" ABOVE THE GRADE. HOOD OVER ELECTRIC RANGE SHALL BE 160CFM OR 65% CE FOR ELECTRICAL RANGE (MAX 3 SONES) PROVIDED UFER OR OTHER APPROVED GROUND PER CEC 250. NOTE: THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING OF 225. RHEEM-HEAT PUMP 40 GAL ELEC. HEAT PUMP PROVIDE BLOCKING FOR FUTURE ADA GRAB BAR ELECTRICAL PLAN SCALE: 1/4" = 1'-0" 12'-9" 27 ' - 1 " 25'-0" 10 ' - 0 " W/D WH PANTRY DW 16 ' - 4 " 9' - 6 " 5' - 6 " 13'-0"2'-1"8'-3" 21' - 0 " (N) ADU ELEC PANEL 200 AMP COND. (N) KITCHEN (N) 9'-0" CL. HT. (N) BEDROOM #1 (N) 9'-0" CL. HT. (N) LIVING ROOM (N) 9'-0" CL. HT. (N) BATH (N) 9'-0" CL. HT. (N) 2'0"X2'0" SLD OBS TEMP WD (N) 4'0"X4'0" SLD WD (N) 5'0"X4'0" SLD TEMP. WD (N ) 4 ' 0 " X 4 ' 0 " S L D W D (N ) 3 ' 0 " X 3 ' 0 " S L D W D (N ) 3 ' 0 " X 6 ' 8 " E N T R Y D R . (N) 2'6"X6'8" LOUVER DR. (N) PORCH (N) 9'-0" CL. HT. 3' - 0 " 10'-6" ESS READY SEE DIAGRAM AFCI AFCIAFCI AFCI AFCI AFCI AFCIAFCI S GFCI SS VS GFCI TYPE 1 CLOTHES DRYER EXHAUST DUCT (MIN. 4 INCH DIA. AND 0.16" THICK RIGID METAL TO OUTSIDE OF THE BUILDING AND EQUIPPED WITH A BACK-DRAFT DAMPER. EXHAUST DUCT LENGTH IS LIMITED TO 14 FT. WITH 2 ELBOWS. (N) SD+CO PHOTOELEC. HB AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI (N) LED PHOTO CONTROL & MOTION SENSOR (N) LED PHOTO CONTROL & MOTION SENSOR D S SS SS S S DD 3 3 AFCI S (N) LED PHOTO CONTROL & MOTION SENSOR (N) LED PHOTO CONTROL & MOTION SENSOR (N) LED PHOTO CONTROL & MOTION SENSOR (N) LED PHOTO CONTROL & MOTION SENSOR PROVIDE NOTE: "EFFECTIVE JANUARY 1, 2014, SENATE BILL 407 REQUIRES A BUILDING PERMIT APPLICANT TO REPLACE ALL NONCOMPLIANT PLUMBING FIXTURES IN PROPERTIES BUILT AND AVAILABLE FOR USE ON OR BEFORE JANUARY 1, 1994 WITH WATER-CONSERVING PLUMBING FIXTURES AS A CONDITION FOR APPROVAL OF A FINAL BUILDING PERMIT FOR BUILDING ALTERATIONS OR IMPROVEMENTS. CONTRACTOR SHALL COMPLETE SB 407 AFFIDAVIT FORM AND SUBMIT TO THE INSPECTOR PRIOR TO FINAL INSPECTION. NON COMPLIANT PLUMBING FIXTURES MEANS ANY OF THE FOLLOWIN 1.ANY TOILET MANUFACTURED TO USE MORE THAN 1.28 GALLONS OF WATER PER FLUSH 2.ANY URINAL MANUFACTURED TO USE MORE THAN ONE GALLON OF WATER PER FLUSH 3. ANY SHOWERHEAD MANUFACTURED TO HAVE A FLOW CAPACITY OF MORE THAN 1.8 GPM 4.ANY INTERIOR FAUCET THAT EMITS MORE THAN 2.0 GPM. 1.THE WHOLE-BUILDING VENTILATION EXHAUST FAN WILL OPERATE CONTINUOUSLY AND IS REQUIRED TO BE RATED FOR SOUND AT A MAXIMUM OF 1 SONE. THIS EXHAUST FAN CAN BE CONTROLLED BY A STANDARD ON/OFF SWITCH BUT THE SWITCH MUST BE LABELED CLEARLY DISPLAYING THE FOLLOWING TEXT, OR EQUIVALENT. "THIS SWITCH CONTROLS THE INDOOR AIR QUALITY VENTILATION FOR THE HOUSE. LEAVE SWITCH IN THE "ON" POSITION AT ALL TIMES UNLESS THE OUTDOORAIR QUALITY IS VERY POOR." [150.0(o)J] WHOLE HOUSE FAN INFO: MANUF. = PANASONIC MODEL # = RG-R811LA 1 SONE RATING WHOLE HOUSE FAN NOTES: AGING-IN-PLACE/FALL PREVENTION NOTES: A.REINFORCEMENT FOR GRAB BARS. [R327.1.1] AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. WHERE THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE BATHROOM ON THE 2ND OR 3RD FLOOR OF THE DWELLING SHALL COMPLY WITH THIS SECTION. 1.REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. 2.REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL LUMBER (1-1/2” X 7-1/4” ACTUAL DIMENSION) OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32” AND 39-1/4” ABOVE THE FINISHED FLOOR, FLUSH WITH THE WALL FRAMING. 3.WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. 4.SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. 5.BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6” ABOVE THE BATHTUB RIM. 6.WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY. B.DOCUMENTATION FOR GRAB BAR REINFORCEMENT. [R327.1.1.1] INFORMATION AND/OR DRAWINGS IDENTIFYING THE LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION & MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CH. 4, DIVISION 4.4. C.DOORBELL BUTTONS. [R327.1.4] DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48” MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE OUTLETS INSTALLED IN DWELLING UNITS SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER(S). [CEC 210.12] NOTE THIS REQUIREMENT IS FOR ENTIRE CIRCUIT, NOT JUST THE OUTLETS. NOTES: 1)PROVIDE SMOKE ALARM IN EACH BEDROOM OR SLEEPING AREA, AND OUTSIDE OF EACH SEPARATE BEDROOM/SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM/SLEEPING AREA. LOCATION OF SMOKE DETECTORS SHALL COMPLY WITH CRC SECTION R314.3.3. HARDWIRED AND INTERCONNECTED SMOKE ALARMS ARE REQUIRED. (CRC R314) 2)PROVIDE CARBON MONOXIDE ALARM OUTSIDE OF EACH SEPARATE BEDROOM/SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM/SLEEPING AREA. HARDWIRED AND INTERCONNECTED CARBON MONOXIDE ALARMS Are Required. (CRC R315) 3)SMOKE ALARMS SHALL BE AT LEAST 3 ' FROM A SUPPLY REGISTER OR A BATHROOM DOOR/OPENING. 4)SMOKE ALARMS SHALL BE AT LEAST 20 ' FROM COOKING APPLIANCE (10' FOR IONIZATION ALARM WITH SILENCING SWITCH OR PHOTOELECTRIC ALARM). NOTES:ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS SHALL BE LOCATED NO MORE THAN 48” MEASURED TO TOP OF THE OUTLET BOX AND NOT LESS THAN 15” MEASURED FROM BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. NOTES: SCALE: DRAWN BY: DATE: PLAN CHECK DRAWING TITLE: DATEREVISIONS: HN 12-11-2024 AS NOTED 00-00-0000 SHEET NO. OF SHEETS DATE 00-00-2024-------- 00-00-0000 00-00-0000 00-00-0000 00-00-0000 CONSULTANT: 21 0 W . H A R V E Y A V E . U N I T # 2 ( A D U ) , SA N T A A N A , C A 9 2 7 0 7 RESIDENTIAL PROJECT FOR: 210 W. HARVEY AVE.(ADU), SANTA ANA, CA 92707 DE T A C H E D A D U P R O J E C T Exp. date: STATE OF CALIFORNIACIVIL REGISTERED PROFESS IONAL ENGINEER HUE C . LUI C-66754 9/26 1/29/2025 HA NGUYEN - 1/29/2025 ELECTRICAL PLAN 06 11 A2 210 W Harvey Ave Unit #24/22/2025 SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa-ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Thai Viet Phan COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org CITY MANAGER Alvaro Nuñez CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall December 10, 2024 Ha Nguyen Also sent via email to: win.nguyen.ent@gmail.com 210 W. Harvey Avenue Santa Ana, CA 92707 Subject: Address Assignment for a new detached ADU at 210 W. Harvey Avenue (APN: 1410-282- 13) in Santa Ana, CA 92707 Dear Mr. Huynh, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a new detached ADU proposed at 210 W. Harvey Avenue (APN: 1410-282-13). Notice is hereby given that the following assigned address(es) shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address(es) to be Activated/Posted To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at 714-667-2728 or by email at CSantana@santa-ana.org. Sincerely, Cristian Santana Cristian Santana Assistant Planner I Exhibit A – Address Plan c: 210 W Harvey Ave Unit #24/22/2025 Address Letter for 210 W. Harvey Avenue (APN: 1410-282-13) Page 2 of 2 Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Ted Walstrom, Santa Ana Unified School District Jeremy Cogan, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing Division Manager Rudy Rosas, Deputy Public Works Director / City Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Services Principal Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Yvette Portugal, Code Enforcement Manager Sergio Verino, Code Enforcement Principal 210 W Harvey Ave Unit #24/22/2025 SHEET INDEX PROJECT DIRECTORY PROPERTY DESCRIPTION VICINITY MAP N.T.S. SCOPE OF WORK PROJECT LOCATION OWNER:JAMES HUYNH (714)791-4750 ZONE:R-1 APN #:410-282-13 STORIES:1 SPRINKLERS: MAIN HOUSE - NO ADU - NO DESIGNER: HA NGUYEN 13172 SANDRA PL., GARDEN GROVE, CA 92843 TEL: (714) 326-3124 CIVIL ENGINEER: SCOPE OF WORK: 1. NEW DETACHED ADU WITH 1 BEDROOM, 1 BATHROOM 2. PV PANELS UNDER SEPARATE PERMIT (E)MAIN HOUSE 1,429 SQ. FT. __________________________________________________________ __________________________________________________________ (E) GARAGE 466 SQ. FT. (E) FRONT PORCH 102 SQ. FT. (E) TRELLIS PATIO 177 SQ. FT. __________________________________________________________ NEW DETACHED ADU 572 SQ. FT. ADU PORCH 32 SQ. FT. __________________________________________________________ LEGAL JURISDICTION: CITY OF SANTA ANA, CALIFORNIA APPLICABLE CODES: FOR ALL BELOW 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (GBC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA ENERGY CODE (TITLE 24, PART 6) SANTA ANA MUNICIPAL CODE RESIDENTIAL DWELLINGS: CONSTRUCTION TYPE: V-B OCCUPANCY GROUP: R-3/U TOTAL LOT COVERAGE 1,997 SQ. FT. 1429+466+102 __________________________________________________________ LOT COVERAGE %:29.6 % LOT AREA: 6,740 SQ. FT. TS COVER SHEET, (E)+(N) SITE PLAN GN GENERAL NOTES GR1 GREEN NOTES GR2 GREEN NOTES A1 (E)+(N) FLOOR PLAN, ELEVATIONS A2 ELECTRICAL PLAN S1 FOUNDATION & FRAMING PLAN, SECTION D1 DETAILS T24 TITLE 24 T24 TITLE 24 HUE C. LIU C -66754 10732 LA BATISTA AVE. FOUNTAIN VALLEY, CA 92708 TEL: (714) 679-6472 .4 MILES FROM BUS ID:6539 W MACARTHUR BLVD. E DYER RD. W WARNER AVE. S B R I S T O L S T . S F L O W E R S T . MA I N S T . 55 F W Y PROJECT SITE 210 W HARVEY AVE. PR O P E R T Y L I N E 9 1 . 9 8 ' PROPERTY LINE 4 3 . 8 3 ' PROPERTY LI N E 6 0 . 5 4 " PR O P E R T Y L I N E 1 0 9 . 8 2 ' PROPERTY LINE 40.95' (E)SITE/ROOF PLAN SCALE: 1/8" = 1'-0" 210 W. HARVEY AVE.℄ PR O P E R T Y L I N E 9 1 . 9 8 ' PROPERTY LINE 4 3 . 8 3 ' PROPERTY L I N E 6 0 . 5 4 " PR O P E R T Y L I N E 1 0 9 . 8 2 ' PROPERTY LINE 40.95' (N)SITE/ROOF PLAN SCALE: 1/8" = 1'-0" 210 W. HARVEY AVE.℄ 12'-9" 27 ' - 1 " 5'-0" 25'-0" 10 ' - 0 " 4'-6" 21' - 0 " SL O P E 4. 5 : 1 2 SL O P E 4. 5 : 1 2 (E)MAIN HOUSE SLOPE 4.5:12 SLOPE 4.5:12 (E)GARAGE (E ) T R E L L I S P A T I O (E)PORCH SL O P E 4. 5 : 1 2 SL O P E 4. 5 : 1 2 (E)MAIN HOUSE SLOPE 4.5:12 SLOPE 4.5:12 (E)GARAGE (E ) T R E L L I S P A T I O (E)PORCH SLOPE 4.5:12 SLOPE 4.5:12 (N) ADU COND. COND. (E) MAIN HOUSE PANEL (E) GAS METER (FIELD VERIFY) 7'-10" 14'-10" 19 ' - 6 " 20 ' - 7 " 8'-7" 35'-5" 20 ' - 1 1 " 21 ' - 5 " 7'-10" 14'-10" 19 ' - 6 " 20 ' - 7 " 8'-7" 20 ' - 1 1 " 21 ' - 5 " (E ) 6 ' - 0 " B L O C K W A L L (E)6'-0" BLOCK W A L L (E)6'-0" BLOC K W A L (E ) 6 ' - 0 " B L O C K W A L L 5'-0"EASEMEN T 5'-0"EASEMEN T (E) GAS METER (FIELD VERIFY) (N) ADU ELEC PANEL 200 AMP (E ) 6 ' - 0 " B L O C K W A L L (E)6'-0" BLOCK W A L L (E)6'-0" BLOC K W A L (E ) 6 ' - 0 " B L O C K W A L L COND. (E) WATER METER (FIELD VERIFY) (E) WATER METER (FIELD VERIFY) FORTNIGHT LILY 1 GALLON TEXAS PRIVET 5 GALLON SPREADING SUNSHINE LANTANA 5 GALLON (E) 24-INCH BOX 3' - 0 " 10'-6" (E) 24-INCH BOX 6' - 3 " (E) MAIN HOUSE PANEL UPGRADE TO DUAL 400 AMP METER (N ) 3 " S E W E R L I N E (N)1"WATER LINE (N) 2"UNDERGROUND CONDUIT (E ) 4 " S E W E R L I N E 2% 9' - 8 " 5' - 1 " 3'-6" P.O.C. P.O.C. CO (N) ESS 5% SLOPE 5% S L O P E 5% S L O P E 5% SLOPE 5% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 2% SLOPE 2% SLOPE LOT SHALL BE GRADED TO DRAIN SURGACE WATER AWAY FROM THE FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6" WITHIN THE FIRST 10FT. (5% SLOPE). WHERE LOT LINES, WALLS, SLOPES OR OTHER PHYSICAL BARRIER PROHIBIT 6" OF FALL WITHIN 10FT. DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. (CRC R401.3) LEGEND EXISTING AREA NEW PROPOSED AREA SCALE: DRAWN BY: DATE: PLAN CHECK DRAWING TITLE: DATEREVISIONS: HN 07-25-2024 AS NOTED 00-00-0000 SHEET NO. OF SHEETS DATE 00-00-2024-------- 00-00-0000 00-00-0000 00-00-0000 00-00-0000 CONSULTANT: 21 0 W . H A R V E Y A V E . , SA N T A A N A , C A 9 2 7 0 7 RESIDENTIAL PROJECT FOR: 210 W. HARVEY AVE., SANTA ANA, CA 92707 DE T A C H E D A D U P R O J E C T Exp. date: STATE OF CALIFORNIACIVIL REGISTERED PROFESSIONAL ENGINEER HUE C . LUI C-66754 9/26 (E)+(N) SITE PLAN, GENERAL DATA 01 10 TS DETACHED ADU PROJECT 210 W. HARVEY AVE., SANTA ANA, CA 92707 Unit 2 Exhibit A 210 W Harvey Ave Unit #24/22/2025 Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)-647-5800 www.santa-ana.org GRADING PERMIT REQUIREMENTS FOR DETACHED ADU PROJECTS PCC-15 REV: 09/03/2020 Page 1 of 1 A grading permit is required for all new detached buildings including new detached Accessory Dwelling Unit (ADU) projects. Grading plans prepared and stamped by a registered professional engineer shall be submitted for approval prior to issuance of the building permit, and shall be required to be submitted before or concurrently with the architectural plans submittal to the Building Safety Division. Grading Permit Exemption: Residential detached Accessory Dwelling Unit (ADU) projects that meet all of the following may be exempted from grading permit requirements: 1. The maximum amount of soil being moved is less than 50 cubic yards. The soil quantities shall be calculated by a California registered professional civil engineer 2. A site drainage plan prepared by a California registered professional civil engineer shall be provided with the following minimum information, but not limited to: a. Plan(s) shall be stamped, signed and dated by a California registered civil engineer b. Location of all existing and proposed structures, property lines, right-of-way lines, and easements, including dimensions and setbacks c. Drainage slopes and flow patterns d. Drainage system such as swales, french drains, water collection and disposal system, etc. e. Drainage plan shall indicate how the site grading or drainage system will manage all surface water flows to be diverted away from buildings and adjoining property lines, in accordance with all applicable codes f. The grade shall fall not fewer than 6 inches within the first 10 feet from the foundation wall. Where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, drains, or swales shall be constructed to ensure drainage away from the structure. Impervious surfaces within 10 feet of the building foundation shall be sloped not less than 2 percent away from the building. 3. A final certification letter from the professional engineer of record stating that the grades were constructed per the approved site drainage plan, shall be submitted to the building inspector prior to final inspection 4. The “Detached ADU Grading Permit Exemption Checklist” shall be completed by the California registered professional civil engineer and shall be made a part of the building plans. 5. The site drainage plan and the completed checklist shall be required at the time of architectural plans submittal as part of the building plans package. The building official reserves the right to require a grading plan based on site conditions. This grading permit exemption does not apply to projects in the FEMA Flood Zone. 210 W Harvey Ave Unit #24/22/2025 210 W Harvey Ave Unit #24/22/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area: Area to be Added: Total Resulting Area: Stories: Area Added in Past 2 Years (excluding this project): Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability (PR400-402) Fire Sprinkler 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has fire sprinklers or a house that will have fire sprinklers added as part of this project? (PR400-402) Fire Sprinkler 3.   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than 140-feet from the fire access roadway? *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all enclosed spaces, such as garages, stairs, and detached structures separated by less than 10-feet? *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed contractor to determine if a fire sprinkler modification is needed. (PR400-402) Fire Sprinkler 7.   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold set by local ordinance? *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 sf, and ADU’s). *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as defined by the State, or (D) near an area that could be affected by a wildfire in the open space. *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR 210 W Harvey Ave Unit #24/22/2025