Loading...
HomeMy WebLinkAbout1908 S Sullivan St - 20183313 - Plan1908 S SULLIVAN ST, SANTA ANA CA 92704 E1 SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d EVOLUTION 06/28/2024 98307 (E)5.72 LE T I C I A S I L V A A N D GL O R I A S I L V A SA N T A A N A C A 9 2 7 0 4 19 0 8 S S U L L I V A N S T , (7 1 4 ) 5 9 7 - 4 6 1 2 40 8 1 0 2 1 1 E N E R G Y S T O R A G E SY S T E M S I Z E : 10 k W h E S S MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 ABBREVIATIONS AMPERE ALTERNATING CURRENT AUTHORITY HAVING JURISDICTION BUILDING CONCRETE COMBINER BOX CALIFORNIA ELECTRICAL CODE COPPER DISTRIBUTION PANEL DIRECT CURRENT EQUIPMENT GROUNDING CONDUCTOR (EXISTING) FIELD VERIFIED GALVANIZED GROUNDING ELECTRODE CONDUCTOR GROUND HOT DIPPED GALVANIZED CURRENT CURRENT AT MAX POWER INVERTER SHORT CIRCUIT CURRENT KILOVOLT AMPERE KILOWATT LOAD BEARING WALL MINIMUM MAIN CIRCUIT BREAKER MAIN SERVICE PANEL (NEW) NEMA 3R, RAINTIGHT OUTSIDE RATED NATIONAL ELECTRICAL CODE NOT TO SCALE ON CENTER OVERCURRENT PROTECTION DEVICE POLES -BREAKER POLES- PROPERTY LINES PHOTOVOLTAIC POLYVINYL CHLORIDE ROOF RAFTER SOLID BARE COPPER SOLAR PLANE SUBPANEL SCHEDULE STAINLESS STEEL PRACTICAL TESTING CONDITIONS SOLAR WATER HEATER TYPICAL UNLESS NOTED OTHERWISE VOLT VOLTAGE AT MAX POWER VOLTAGE AT OPEN CIRCUIT WATT A AC AHJ BLDG CONC CB CEC CU DP DC EGC (E) FV GALV GEC GND HDG I Imp INVT Isc kVA kW LBW MIN. MCB MSP (N) N3R NEC NTS OC OCPD P PL PV PVC RR SBC SP SPL SCH SS PTC SWH TYP UNO V Vmp Voc W SHEET INDEX APPLICABLE CODES AND STANDARDS VICINITY MAP N SCOPE OF WORK ·2022 CBC ·2022 CRC ·2022 CEC ·2022 CMC ·2022 CPC ·2022 CFC ·2022 CEBC · 2022 BUILDING ENERGY EFFICIENCY STANDARDS · AUTHORITY HAVING JURISDICTION · CURRENT LOCAL FIRE CODE 1. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 2. EQUIPMENT. INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC PHOTOVOLTAIC MODULES, SOURCE-CIRCUIT COMBINERS, AND CHARGE CONTROLLERS INTENDED FOR USE IN PHOTOVOLTAIC POWER SYSTEMS SHALL BE IDENTIFIED AND LISTED FOR THE APPLICATION. [CEC 690.4(B)] 3. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND NON ROOF SWITCHES. ROOF SWITCHES TO BE NEMA 4 RATED. 4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. 5. PROTECTION DEVICES FOR PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS ALSO CONNECTED TO SOURCES HAVING SIGNIFICANTLY HIGHER CURRENT AVAILABILITY (E.G., PARALLEL STRINGS OF MODULES, UTILITY POWER), SHALL BE PROTECTED AT THE SOURCE FROM OVERCURRENT. [CEC 690.9(A)] 6. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS. [CEC 690.12] 7. THE UTILITY INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. [CEC 705.40] 8. ALL CONDUCTOR EXPOSED TO WEATHER SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT. [CEC 310.10(D)(1)] 9. THE MODULE CONDUCTORS MUST BE TYPE USE-2 OR LISTED FOR PHOTOVOLTAIC (PV) WIRE. [CEC 690.31(C)] 10. ALL CONDUCTORS SHALL BE MARKED ON EACH END FOR UNIQUE IDENTIFICATION. 11. AN INSULATED GROUNDED CONDUCTOR OF 6 AWG OR SMALLER SHALL BE IDENTIFIED AS A CONTINUOUS WHITE FINISH. [CEC 200.6] 12. THE OUTPUT OF AN INTERCONNECTED ELECTRICAL POWER SOURCE SHALL BE PERMITTED TO BE CONNECTED TO THE LOAD SIDE. INTERCONNECTING PROVISIONS FOR OTHER POWER SOURCES SHALL COMPLY WITH 705.12(B)(1) THROUGH 705.12(B)(3) 13. EACH SOURCE INTERCONNECTION OF ONE OR MORE POWER SOURCES INSTALLED IN ONE SYSTEM SHALL BE MADE AT A DEDICATED CIRCUIT BREAKER OR FUSIBLE DISCONNECTING MEANS. [CEC 705.12(A)] 14. THE SUM OF THE AMPERE RATING OF THE OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO THE BUSBAR OR CONDUCTOR SHALL NOT EXCEED 120% OF THE RATING OF BUSBAR OR CONDUCTOR. [CEC 705.12(B)(3)(2)] 15. A CONNECTION AT EITHER END, BUT NOT BOTH ENDS, OF A CENTER-FED PANEL BOARD IN DWELLINGS SHALL BE PERMITTED WHERE THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR DOES NOT EXCEED 120 PERCENT OF THE CURRENT RATING OF THE BUSBAR. [CEC 705.12(B)(3)(4)] 16. EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUS BAR OR CONDUCTOR SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. [CEC 705.12(C)] 17. CIRCUIT BREAKER, IF BACKFED, SHALL BE SUITABLE FOR SUCH OPERATION. [CEC 705.12(D)] 18. TO MINIMIZE OVERHEATING OF THE BUSBAR IN PANELBOARD, THE PANELBOARD MAIN CIRCUIT BREAKER AND THE PV POWER SOURCE CIRCUIT BREAKER SHALL BE PHYSICALLY LOCATED AT THE OPPOSITE END OF THE BUSBAR. 19. ALL THE CEC REQUIRED WARNING SIGNS, MARKINGS, AND LABELS SHALL BE POSTED ON EQUIPMENT AND DISCONNECTS PRIOR TO ANY INSPECTIONS TO BE PERFORMED BY THE BUILDING DEPARTMENT INSPECTOR. 20. WHERE PV SYSTEM DC CIRCUIT'S RUN INSIDE A BUILDING, THEY SHALL BE CONTAINED IN METAL RACEWAYS TYPE MC METAL CLAD CABLE OR METAL ENCLOSURES FROM POINT OF PENETRATION OF THE SURFACE OF THE BUILDING TO THE FIRST READILY ACCESSIBLE DISCONNECTING MEANS. [CEC 690.31(D)] 21. FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR THAT ARE IS IN ACCORDANCE WITH CEC 110.14. 22. CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30V DC OR 15V AC SHALL REQUIRE TOOL TO OPEN AND MARKED "DO NOT DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT INTERRUPTING". [CEC 690.33(C) & (D)] 23. EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR. [CEC 250.120(C)] 24. EQUIPMENT GROUNDING CONDUCTOR FOR PV SYSTEM CIRCUITS SHALL BE SIZED IN ACCORDANCE WITH 250.122. [CEC 690.45] 25. GROUNDING ELECTRODE CONDUCTOR(S) SHALL BE INSTALLED IN ONE CONTINUOUS LENGTH WITHOUT A SPLICE OR JOINT. IF NECESSARY, SPLICES OR CONNECTIONS SHALL BE MADE AS PERMITTED. [CEC 250.64(C)] 26. ALL SMOKE ALARMS, CARBON MONOXIDE ALARMS AND AUDIBLE NOTIFICATION DEVICES SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 217 AND UL 2034. THEY WILL BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND NFPA 720. [CRC R314 & R315] 27. SMOKE ALARMS AND CARBON MONOXIDE ALARMS WILL BE RETROFITTED INTO THE EXISTING DWELLING. THESE SMOKE ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. THESE ALARMS MAY BE SOLELY BATTERY OPERATED IF THE PHOTOVOLTAIC PROJECT DOES NOT INVOLVE THE REMOVAL OF INTERIOR WALL AND CEILING FINISHES INSIDE THE HOME, OTHERWISE, THE ALARMS MUST BE HARD WIRED AND INTERCONNECTED. GENERAL NOTES *ALL WORK TO COMPLY WITH ABOVE CODES * OCCUPANCY TYPE: R-3 * CONSTRUCTION TYPE: TYPE V-B * UNSPRINKLERED DWELLING INFO ·(10) KWH RATED ENERGY STORAGE SYSTEM ·(2) ENPHASE IQ BATTERY 5P-1P-NA ·(1) 200A ENPHASE IQ SYSTEM CONTROLLER 3 ·(1) RAPID SHUTDOWN DEVICE ·(1) 125A SELECTED LOAD CENTER ·(1) 60A AC DISCONNECT 01 - E1 COVER SHEET 02 - E2 SITE PLAN 05 - E7 SINGLE LINE DIAGRAM 07 - E8 ELECTRICAL NOTES 10 - E9 SIGNAGE 08 - E8.1 BATTERY INSTALL DIAGRAM 11 - E9.1 SIGNAGE 12 - E9.2 SIGNAGE 13 - JHA 04 - E4 ELECTRICAL ELEVATION 06 - E7.1 ELECTRICAL CALCULATION 09 - E8.1A PANEL SCHEDULE THIS INSTALLATION WILL PROVIDE PARTIAL HOME BACKUP. THE FOLLOWING LOADS WILL BACKUP. 1. 20A/1P PLUGS 2. 20A/1P MICROWAVE 3. 20A/1P PLUGS 4. 20A/1P KITCHEN PLUGS 5. 20A/1P REFRIGERATOR 6. 20A/1P PLUGS 7. 15A/1P LIGHT 8. 15A/1P LIGHT 9. 20A/1P PLUGS 10. 20A/1P PLUGS EXISTING AC SYSTEM SIZE = 5.13 KW 03 - E3 PROPERTY PLAN No. E 22012 SESFIOONRAP LDEENRGETINSIEGEERR E LLAECCITRS ATIANTEROOFFIL CA AMN IERDAOGHUTHE AM Exp. 09/30/25 STAMPED 06/28/2024 Elec: 20183313 Approvals: Elec: MSmith 1908 S Sullivan St - 201833137/30/2024 MSP ACC MIDSLC ESSESSACDACDRSD E2 SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d EVOLUTION 05/24/2024 98307 (E)5.72 LE T I C I A S I L V A A N D GL O R I A S I L V A SA N T A A N A C A 9 2 7 0 4 19 0 8 S S U L L I V A N S T , (7 1 4 ) 5 9 7 - 4 6 1 2 40 8 1 0 2 1 1 E N E R G Y S T O R A G E SY S T E M S I Z E : 10 k W h E S S MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 SCALE: SITE PLAN N 3/32" = 1'-0" LEGEND (E) 200A BUS CF (E) 200A MAIN BREAKER (N) 70A BRANCH BREAKER FEEDING (N) ENPHASE IQ SYSTEM CONTROLLER 3 SERVICE POINT & UTILITY METERING MSP 13 (E) DNA-144-MF26-440W SOLAR MODULES EACH WITH AN (E) ENPHASE IQ8A-72-2-US MICRO-INVERTER (FLUSH MOUNT) ACC (E) 125A ENPHASE IQ COMBINER 4C WITH ENVOY IQ, CELL MODEM, & WIRED COMMUNICATIONS KIT (N) 200A ENPHASE IQ SYSTEM CONTROLLER 3 POC FOR 2 (N) BATTERIES & (E) IQ COMBINER 4C LOAD SIDE LUG FEEDING (N) 125A SLC MID ACD (E) 30A AC DISCONNECT 240V NEMA-3R 2 (N) ENPHASE IQ BATTERY 5P-1P-NA ENERGY STORAGE SYSTEM, 240V NEMA-3RESS (N) 125A SELECTED LOAD CENTER (ALL BACKUP LOADS WILL RELOCATE FROM MSP) SLC ACD (N) 60A AC DISCONNECT 240V NEMA-3R 3'0" WORKING DISTANCES AND CLEARANCES FOR THE EQUIPMENT ELECTRICAL SWITCHBOARD UTILITY METER & MAIN SERVICE PANEL POINT OF CONNECTION SITE ADDRESS : 1908 S SULLIVAN ST, SANTA ANA CA 92704 AC DISCONNECT RSD (N) RAPID SHUTDOWN DEVICE (LOCATED NEAR MSP) 1908 S Sullivan St - 201833137/30/2024 MSP ACC MIDSLC ESSESSACDACDRSD EX I S T I N G HO U S E FR O N T O F RE S I D E N C E EX I S T I N G DR I V E W A Y 100' 60 ' 60 ' 100' 3' 11 ' - 3 " 11 ' - 3 " S S U L L I V A N S T SCALE: PROPERTY PLAN N 3/32" = 1'-0"E3 SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d EVOLUTION 06/28/2024 98307 (E)5.72 LE T I C I A S I L V A A N D GL O R I A S I L V A SA N T A A N A C A 9 2 7 0 4 19 0 8 S S U L L I V A N S T , (7 1 4 ) 5 9 7 - 4 6 1 2 40 8 1 0 2 1 1 E N E R G Y S T O R A G E SY S T E M S I Z E : 10 k W h E S S MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 EXISTING GATE EXISTING SINGLE STOREY RESIDENCE EXISTING PATIO EXISTING PROPERTY LINE EXISTING FENCE EXISTING GATE EXISTING DETACHED STRUCTURE 1908 S Sullivan St - 201833137/30/2024 3' NORTH-EAST SIDE EXTERIOR WALL (E) MAIN PANEL ESS DISCONNECT SWITCH 6" ENPHASE COMBINER ACD 30ASELECTED LOAD CENTER 3' ENPHASE IQ SYSTEM CONTROLLER 3 3' WINDOW ENPHASE IQ BATTERY 5P ACD 60A ENPHASE IQ BATTERY 5P 3" 6" 6" 1'-8" 9"6" 1'-8" 11"6" (E) (E) 6" WINDOWWINDOW 6" 3' - 6 " 3'3' 5'-1" (E) VENTILATION (E) CHIMNEY E4 SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d EVOLUTION 06/28/2024 98307 (E)5.72 LE T I C I A S I L V A A N D GL O R I A S I L V A SA N T A A N A C A 9 2 7 0 4 19 0 8 S S U L L I V A N S T , (7 1 4 ) 5 9 7 - 4 6 1 2 40 8 1 0 2 1 1 E N E R G Y S T O R A G E SY S T E M S I Z E : 10 k W h E S S MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 SCALE: ELECTRICAL ELEVATION NTS No. E 22012 SESFIOONRAP LD EENRGETINSIEGEERR E LLAECCITRS ATIANTER OOFFI L CA AMN IERDAOGHUTHE AM Exp. 09/30/2 5 STAMPED 06/28/2024 1908 S Sullivan St - 201833137/30/2024 MSP ACC MIDSLC ESSESSACDACDRSD 1908 S SULLIVAN ST, SANTA ANA CA 92704 JHA SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d EVOLUTION 06/28/2024 98307 (E)5.72 LE T I C I A S I L V A A N D GL O R I A S I L V A SA N T A A N A C A 9 2 7 0 4 19 0 8 S S U L L I V A N S T , (7 1 4 ) 5 9 7 - 4 6 1 2 40 8 1 0 2 1 1 E N E R G Y S T O R A G E SY S T E M S I Z E : 10 k W h E S S MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 NEAREST URGENT CARE VICINITY MAP DISTANCE ADDRESS NAME CONDITIONS NCREW MEMBER CREW LEAD CREW MEMBER CREW MEMBER ROPE REACH LADDER ACCESS CONES EXCLUSION ZONE JHA LEGEND ANCHOR POINTS N THIS PAGE TO BE COMPLETED BY INSTALLATION CREW 1908 S Sullivan St - 201833137/30/2024 E7.1 SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d EVOLUTION 06/28/2024 98307 (E)5.72 LE T I C I A S I L V A A N D GL O R I A S I L V A SA N T A A N A C A 9 2 7 0 4 19 0 8 S S U L L I V A N S T , (7 1 4 ) 5 9 7 - 4 6 1 2 40 8 1 0 2 1 1 E N E R G Y S T O R A G E SY S T E M S I Z E : 10 k W h E S S MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 UTILITY COMPANY:MSP VOLTAGE: MSP GROUND:SERV. TYPE: SERVICE INFO MSP PHASE: 1-PHASE (E) UFEROVERHEAD 120/240SCE THIS INSTALLATION WILL PROVIDE PARTIAL HOME BACKUP. THE FOLLOWING LOADS WILL BACKUP. 1.20A/1P PLUGS 2.20A/1P MICROWAVE 3.20A/1P PLUGS 4.20A/1P KITCHEN PLUGS 5.20A/1P REFRIGERATOR 6.20A/1P PLUGS 7.15A/1P LIGHT 8.15A/1P LIGHT 9.20A/1P PLUGS 10.20A/1P PLUGS INTERCONNECTION METHOD PER 705.12(B)(3)(3): THE SUM OF THE AMPERE RATINGS OF ALL OVERCURRENT DEVICES ON PANELBOARDS, BOTH LOAD AND SUPPLY DEVICES, EXCLUDING THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR, SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED THE RATING OF THE BUSBAR. 2% Avg. 1"MIN ASHRAE AMBIENT TEMPERATURE SPECS ° C ° C High Temp EXTREMEDISTANCE ABOVE ROOF NO TEMP ADDER PER 310.15(B)(2)31 2 NEW PV CONDUIT TO HIDDEN FROM VIEW. CONDUIT TO BE PAINTED TO MATCH THE EXISTING SURFACE. CONDUIT RUN TO BE DETERMINED BY INSTALLER. WIRE OCP FOR WIRES CONNECTED TO BREAKERS TO BE GREATER THAN THE SIZE OF THE BREAKER. EQUIPMENT TERMINALS ARE RATED AT 75°C. STRING AMPERAGE NOT TO EXCEED THE 75°C RATING OF THE WIRE THAT IS ATTACHED TO THE TERMINALS. NOTES WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. 70A SUB BREAKER+20A WASHER+20A DRYER =100A TOTAL AMPS 110A < 200A MAIN AND 200A BUS RATING NOTES :- (1) ENCHARGE BATTERY SYSTEM ENERGY CAPACITY SHALL BE SIZED TO SUPPLY ALL DESIRED LOADS DURING AN OUTAGE. POWER CAPACITY OF THE ENCHARGE BATTERY SYSTEM SHALL BE CAPABLE OF SUPPLYING THE LARGEST LOAD ON SITE, PER 2022 NEC 710.15(A) & NEC 710.15(E). (2) ENCHARGE BATTERY STORAGE DISCONNECT SHALL BE SECURED USING AN EATON TYPE-BR CIRCUIT BREAKER HOLD DOWN KIT #BRHDK125 (2022 NEC 710.15(E)). (3) DISTANCE BETWEEN ENPOWER AND ENCHARGE SHOULD BE LESS THEN 5' ELSE AN AC DISCONNECT WILL BE REQUIRED. (4) INSTALLER TO VERIFY HOW ENCLOSURE ARE COUPLED TOGETHER VIA CHASE NIPPLE/ CONDUIT. (5) LINE SIDE TAP FED REQUIRES A EITHER A DISCONNECT OR MAIN BREAKER, OVER 10’ REQUIRES A FUSED DISCONNECT PER NEC, FUSES MUST MEET MAIN BREAKER CRITERIA OF ESS AND PV OR MAX LOAD WHICHEVER IS LARGER. (6) SINGLE LARGEST BREAKER IN BACKED UP LOAD PANEL CANNOT EXCEED THE (ESS) STORAGE OUTPUT CAPACITY (40AAC) PER NEC 710.15 (7) ENCHARGE BATTERY SYSTEM SHOULD NOT BE LOCATED IN DIRECT SUNLIGHT (SOUTH WALL). (8) IF THERE ARE COMMUNICATION ISSUE BETWEEN IQ COMBINER/ENCHARGE TO ENVOY, A USB EXTENDER CABLE BE USE TO RELOCATE THE COMMS KIT NEAR THE IQ COMBINER AND ENCHARGE. (9) THE CONDUCTOR LENGTH BETWEEN THE THE PV ARRAY AND IQ COMBINER SHOULD NOT EXCEED 150 FEET. NOTES: 1) SINGLE LARGEST BREAKER IN BACKED UP LOAD PANEL CANNOT EXCEED THE (ESS) STORAGE OUTPUT CAPACITY (40 AAC), CONTINUOUS RATING OF (32 AAC), AND SURGE OF (64AAC) FOR 3 SECONDS AND (51.2 AAC) FOR 10 SECONDS PER NEC 710.15. 2) WOULD NEED TO RELOCATE LARGER LOADS THAN 40A UNDER NON BACKED UP LOADS OR NEED TO INCREASE NUMBER OF BATTERY. CEC 705.12(B)(3)(3) FOR MSP No. E 22012 SESFIOONRAP LD EENRGETINSIEGEERR E LLAECCITRS ATIANTER OOFFI L CA AMN IERDAOGHUTHE AM Exp. 09/30/2 5 STAMPED 06/28/2024 1908 S Sullivan St - 201833137/30/2024 BATTERY INPUT COMBINER INPUT AC COMBINER GND N AUX CONTACTS N01 N02 NC1NC2 NC3NC4 N03 CONSUMPTION CTs TO IQ GATEWAY INSIDE IQ COMBINER 300KCM - #1 30 0 K C M - # 1 40A/2P IQ BATTERY GN D N (N) 125A SELECTED LOAD CENTER, 240V THE ESS CIRCUIT BREAKER SHALL BE SECURED IN PLACE BY AN ADDITIONAL FASTENER PER SECTION 408.36(D). THE BREAKER AND FASTENER SHALL BE MADE BY THE SAME MANUFACTURER PRODUCER'S STORAGE DEVICE(S) WILL NOT CAUSE THE HOST LOAD EXCEED ITS NORMAL PEAK DEMAND. NORMAL PEAK DEMAND IS DEFINED AS THE HIGHEST AMOUNT OF POWER REQUIRED FROM THE DISTRIBUTION SYSTEM BY PRODUCER'S COMPLETE FACILITIES WITHOUT THE INFLUENCE OR USE OF ENERGY STORAGE DEVICES. (N)70A/2P 25A/2P TRANSFER ALL BACKUP LOADS FROM (E) MSP (N) 200A ENPHASE IQ SYSTEM CONTROLLER 3 ENPHASE SC200D111C240US01 BREAKERS IN IQ SYSTEM CONTROLLER 3 WILL BE SECURED WITH HOLD DOWN KITS. THIS WILL SATISFY THE REQUIREMENTS OF SECTION 408.36 (D) (N) RAPID SHUTDOWN DEVICE (NEC 706.15) THE ESS CIRCUIT BREAKER SHALL BE SECURED IN PLACE BY AN ADDITIONAL FASTENER PER SECTION 408.36(D). THE BREAKER AND FASTENER SHALL BE MADE BY THE SAME MANUFACTURER SYSTEM CAN OPERATE IN ISLAND MODE THIS MID ALLOWS A MICROGRID SYSTEM TO SEPARATE FROM AND RECONNECT TO OPERATE IN PARALLEL WITH A PRIMARY POWER SOURCE (2022 NEC, ARTICLE 705) (E) G (N) 60A AC DISCONNECT EATON DG222URB 240V NEMA-3R (N) MAIN SERVICE PANEL,240V GROUNDING ELECTRODE & AUXILIARY GROUNDING ELECTRODE AS NEEDED PER CEC 690.47 (6 FEET APART) (E)200A CENTER FED ME T E R # 2 2 2 0 1 3 - 5 8 7 2 1 5 (E) 200A/2P (N) 70A/2P L LL L GN D N (E) LOADS 1-PHASE + - CTRL (N) ENPHASE ENERGY IQBATTERY-5P-1P-NA [240V] [SI1-SB] + IQ CONTROLLER 3 SC200D111C240US01 + IQ COMBINER 4C X-IQ-AM1-240-5C [CRD-PCS NEM] + - CTRL(N) ENPHASE ENERGY IQBATTERY-5P-1P-NA [240V] [SI1-SB] + IQ CONTROLLER 3 SC200D111C240US01 + IQ COMBINER 4C X-IQ-AM1-240-5C [CRD-PCS NEM] THWN-2 3-#8 1-#8 GRND 3/4" EMT CONDUIT AFCI PROTECTION WILL BE PROVIDED FOR 15A AND 20A BREAKERS THAT ARE RELOCATED MORE THAN 6' FROM THE ORIGINAL BREAKER SOURCE (E) 125A ENPHASE IQ COMBINER 4C NEMA-3R X-IQ-AM-1-240-4C [CRD-PCS NEM) 15A/2P 20A/2P EXISTING SOLAR 5.72kW DC, 240V (13) DNA-144-MF26-440W SOLAR MODULES (13) ENPHASE IQ8A-72-2-US MICROINVERTER, 240 (1) 125A ENPHASE COMBINER 4C (1) 30A AC DISCONNECT EACH WITH AN (E) ENPHASE IQ8A-72-2-US MICROINVERTER, 240V AC (E) J-BOX G 1 BRANCH OF MODULES07 EE (E) 30A AC DISCONNECT SQUARE-D 240V NEMA-3R G (EXISTING) THWN-2 3-#10 1-#8 GRND 3/4" EMT CONDUIT THWN-2 3-#4 1-#8 GRND 1" EMT CONDUIT THWN-2 3-#4 1-#8 GRND 1" EMT CONDUIT EACH WITH AN (E) ENPHASE IQ8A-72-2-US MICROINVERTER, 240V AC (E) J-BOX G 1 BRANCH OF MODULES06 EE 20A/2P THWN-2 3-#8 1-#8 GRND 3/4" EMT CONDUIT THWN-2 3-#8 1-#8 GRND 3/4" EMT CONDUIT NFT NFT ENPHASE IQ GATEWAY ENV2-IQ-AM1-240 enphase ENERGY ENPHASE C E L L MODEM WIRELESS COMMUNICATION ADAPTER FOR ENPHASE ENERGY SYSTEM CELLULAR REVENUE-GRADE PRODUCTION METERING FACTORY INSTALLED 40A/2P E7 SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d EVOLUTION 06/28/2024 98307 (E)5.72 LE T I C I A S I L V A A N D GL O R I A S I L V A SA N T A A N A C A 9 2 7 0 4 19 0 8 S S U L L I V A N S T , (7 1 4 ) 5 9 7 - 4 6 1 2 40 8 1 0 2 1 1 E N E R G Y S T O R A G E SY S T E M S I Z E : 10 k W h E S S MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 THIS INSTALLATION WILL PROVIDE PARTIAL HOME BACKUP. THE FOLLOWING LOADS WILL BACKUP. 1. 20A/1P PLUGS 2. 20A/1P MICROWAVE 3. 20A/1P PLUGS 4. 20A/1P KITCHEN PLUGS 5. 20A/1P REFRIGERATOR 6. 20A/1P PLUGS 7. 15A/1P LIGHT 8. 15A/1P LIGHT 9. 20A/1P PLUGS 10. 20A/1P PLUGS No. E 22012 SESFIOONRAP LDEENRGETINSIEGEERR E LLAECCITRS ATIANTEROOFFIL CA AMN IERDAOGHUTHE AM Exp. 09/30/25 STAMPED 06/28/2024 There appears to be 14 current carrying conductors for the backup loads. If all within one conduit longer than 24", ampacity reduction will apply and the wire sizes will need to be increased. Refer to CEC 310.15, 310.15(C)(1) MAS(19) 1908 S Sullivan St - 201833137/30/2024 E8.1A SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d EVOLUTION 06/28/2024 98307 (E)5.72 LE T I C I A S I L V A A N D GL O R I A S I L V A SA N T A A N A C A 9 2 7 0 4 19 0 8 S S U L L I V A N S T , (7 1 4 ) 5 9 7 - 4 6 1 2 40 8 1 0 2 1 1 E N E R G Y S T O R A G E SY S T E M S I Z E : 10 k W h E S S MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 PANEL SCHEDULE FOR RELOCATED LOADS 1/P-1/S 20A 1/P-1/S 20A 1/P-1/S 15A 1/P-1/S 15A 1/P-1/S 20A 1/P-1/S 20A PLUGS MICROWAVE 1/P-1/S 20A 1/P-1/S 20A PLUGS KITCHEN PLUGS 1/P-1/S 20A 1/P-1/S 20A REFRIGERATOR PLUGS PLUGS PLUGS LIGHTS LIGHTS No. E 22012 SESFIOONRAP LD EENRGETINSIEGEERR E LLAECCITRS ATIANTER OOFFI L CA AMN IERDAOGHUTHE AM Exp. 09/30/2 5 STAMPED 06/28/2024 1908 S Sullivan St - 201833137/30/2024 E8.1 SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d EVOLUTION 05/24/2024 98307 (E)5.72 LE T I C I A S I L V A A N D GL O R I A S I L V A SA N T A A N A C A 9 2 7 0 4 19 0 8 S S U L L I V A N S T , (7 1 4 ) 5 9 7 - 4 6 1 2 40 8 1 0 2 1 1 E N E R G Y S T O R A G E SY S T E M S I Z E : 10 k W h E S S MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 ENPHASE IQ BATTERY 5BATTERY INSTALL DIAGRAM 1908 S Sullivan St - 201833137/30/2024 ELECTRICAL NOTES: 1)ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER’S INSTALLATION INSTRUCTIONS. 2)ALL PV EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTED LAB. 3)NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. 4)WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ LINE AND LOAD. 5)WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKER SHALL BE INSTALLED AT THE OPPOSITE END OF THE BUS BAR OF THE MAIN BREAKER. 6)WORKING SPACE FOR EQUIPMENT OPERATING AT 1000 VOLTS, NOMINAL, OR LESS TO GROUND AND LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE WHILE ENERGIZED SHALL COMPLY WITH [CEC 110.26(A)] 7)ALL EXTERIOR CONDUITS, FITTINGS AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS PER [CEC 314.15]. 8)ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. 9)PV EQUIPMENT, SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL ONLY BE INSTALLED BY QUALIFIED PERSONS. [CEC 690.4 (C)]. 10)THE PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATED COLOR CODING, MARKING TAPE, TAGGING OR OTHER APPROVED MEANS. [CEC 690.31(B)(1)] 11)ADEQUATE SPACING MUST BE MAINTAINED BETWEEN ANY PLUMBING SEWER VENTS EXTENDING THROUGH THE ROOF AND THE UNDERSIDE OF THE PHOTOVOLTAIC PANELS (6" MINIMUM RECOMMENDED). E8 SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d EVOLUTION 06/28/2024 98307 (E)5.72 LE T I C I A S I L V A A N D GL O R I A S I L V A SA N T A A N A C A 9 2 7 0 4 19 0 8 S S U L L I V A N S T , (7 1 4 ) 5 9 7 - 4 6 1 2 40 8 1 0 2 1 1 E N E R G Y S T O R A G E SY S T E M S I Z E : 10 k W h E S S MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 LOAD CALCULATIONS FOR BACKUP LOAD No. E 22012 SESFIOONRAP LD EENRGETINSIEGEERR E LLAECCITRS ATIANTER OOFFI L C A AMN IERDAOGHUTHE AM Exp. 09/30/2 5 STAMPED 06/28/2024 1908 S Sullivan St - 201833137/30/2024 MSPACCMIDSLC ESS ESS ACD ACD RSD CAUTION POWER TO THIS SERVICE IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: PLACARD RIVETED TO THE MAIN SERVICE PANEL E9.1 SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d EVOLUTION 06/28/2024 98307 (E)5.72 LE T I C I A S I L V A A N D GL O R I A S I L V A SA N T A A N A C A 9 2 7 0 4 19 0 8 S S U L L I V A N S T , (7 1 4 ) 5 9 7 - 4 6 1 2 40 8 1 0 2 1 1 E N E R G Y S T O R A G E SY S T E M S I Z E : 10 k W h E S S MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 N 240V 06-25-2024 69.6 KA PHOTOVOLTAIC POWER SOURCE OPERATING AC VOLTAGE: V MAXIMUM OPERATING AC OUTPUT CURRENT: AMPS LABEL FOR MAIN SERVICE PANEL COVER 240 51 THIS IS THE COMBINED AMPERAGE OF (E) IQ COMBINER & 2(N) BATTERIES QTY. 2 PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: A NOMINAL OPERATING AC VOLTAGE: V 51 240 LABEL FOR RAPID SHUTDOWN SWITCH QTY. 1 WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. QTY. 1 PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: A NOMINAL OPERATING AC VOLTAGE: V 32 240 LABEL FOR ESS AC DISCONNECT QTY. 1 AC DISCONNECT 1 OF 1 YOU ARE HERE SERVICE POINT & UTILITY METERINGSTORAGE BATTERY DISCONNECTSTORAGE BATTERY STORAGE BATTERY DISCONNECT SWITCH AC DISCONNECT SOLAR ARRAY NO RSD THESE MODS AC DISCONNECT PV DISCONNECT SITE ADDRESS: 1908 S SULLIVAN ST,SANTA ANA CA 92704 No. E 22012 SESFIOONRAP LD EENRGETINSIEGEERR E LLAECCITRS ATIANTER OOFFI L CA AMN IERDAOGHUTHE AM Exp. 09/30/2 5 STAMPED 06/28/2024 1908 S Sullivan St - 201833137/30/2024 ADDITIONAL BATTERY PLACARDS E9.2 SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d EVOLUTION 06/28/2024 98307 (E)5.72 LE T I C I A S I L V A A N D GL O R I A S I L V A SA N T A A N A C A 9 2 7 0 4 19 0 8 S S U L L I V A N S T , (7 1 4 ) 5 9 7 - 4 6 1 2 40 8 1 0 2 1 1 E N E R G Y S T O R A G E SY S T E M S I Z E : 10 k W h E S S MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 WARNING INVERTER OUTPUT CONNNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED CAUTION TRI POWER SOURCE SECOND SOURCE IS AC BATTERY THIRD SOURCE IS PHOTOVOLTAIC SYSTEM INFORMATIONAL NOTE: ANSI Z535.4 PROVIDES GUIDELINES FOR THE DESIGN OF SAFETY SIGNS AND LABELS FOR APPLICATION TO PRODUCTS. A PHENOLIC PLAQUE WITH CONTRASTING COLORS BETWEEN THE TEXT AND BACKGROUND WOULD MEET THE INTENT OF THE CODE FOR PERMANENCY. NO TYPE SIZE IS SPECIFIED, BUT 20A POINT (3/8") SHOULD BE CONSIDERED THE MINIMUM. LABEL LOCATIONS: -MAIN PANEL -SUB PANELS LABEL LOCATIONS: -BATTERY SUBPANEL -SUB PANELS LABEL LOCATIONS: -BATTERIES -INVERTER LABEL LOCATIONS: -SERVICE DISCONNECT -SUB PANELS SOLAR BATTERY 1 OF 2 2 OF 2 ENERGY STORAGE SYSTEM DISCONNECT NORMAL ESS VOLTAGE: MAX SYSTEM SHORT CIRCUIT: ASSOCIATED ESS CLEARING TIME: DATE CALCULATION PERFORMED: 240 V 32 A 160 MS 06/25/2024 FOR ESS DISCONNECT SWITCH/ESS MID BATTERY SUB PANEL (IF USED) 16 5 BATTERY UNIT BATTERY EDSBATTERY MID 5 5 16 17 18 17 18 18 No. E 22012 SESFIOONRAP LD EENRGETINSIEGEERR E LLAECCITRS ATIANTER OOFFI L C A AMN IERDAOGHUTHE AM Exp. 09/30/2 5 STAMPED 06/28/2024 1908 S Sullivan St - 201833137/30/2024 MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DC PV CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. MARKING SHALL BE PLACED EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS, AND AT ALL PV COMBINER AND JUNCTION BOXES. [CEC 690.31(D)(2)] REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT) MARKING CONTENT AND FORMAT PER [ CEC 110.21(B)] WITH REFERENCE TO ANSI Z535.4-2011 -BACKGROUND PER ANSI Z535.4-2011 -LETTERING PER ANSI Z535.4-2011 -MINIMUM 3/8” LETTER HEIGHT -ALL CAPITAL LETTERS -ARIAL OR SIMILAR FONT, NON BOLD MARKING PV CIRCUIT E9 SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d EVOLUTION 06/28/2024 98307 (E)5.72 LE T I C I A S I L V A A N D GL O R I A S I L V A SA N T A A N A C A 9 2 7 0 4 19 0 8 S S U L L I V A N S T , (7 1 4 ) 5 9 7 - 4 6 1 2 40 8 1 0 2 1 1 E N E R G Y S T O R A G E SY S T E M S I Z E : 10 k W h E S S MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 1 13 144 8 3 2 13 12 11 9 5 PV COMBINER (IF USED) FOR ILLUSTRATION ONLY (NOT ACTUAL MSP) MAIN SERVICE PANEL AC DISCONNECT (IF USED) LABEL LEGEND 9 1 2 4 4 5 8 13 13 5 5 15 15 CEC 690.56(C) CEC 690.13(B) CEC 690.13(B) CEC 705.12(B)(3)(2) CEC 110.27(C)CEC 706.15(C)(4), CEC 690.13(B)CEC 705.12(B)(3)(3) CEC 705.12(D)CEC 690.56(C)(2) 8 9 9 14 CEC 690.54 240V 32A No. E 22012 SESFIOONRAP LD EENRGETINSIEGEERR E LLAECCITRS ATIANTER OOFFI L CA AMN IERDAOGHUTHE AM Exp. 09/30/2 5 STAMPED 06/28/2024 1908 S Sullivan St - 201833137/30/2024 STRUCTURAL CALCULATIONS FOR LETICIA & GLORIA SILVA (BATTERY) 1908 S SULLIVAN ST SANTA ANA CA 92704 ENGINEER: BWU Consultants, Inc 1168 San Gabriel Blvd #N Rosemead, CA 91770 1908 S Sullivan St - 201833137/30/2024 USGS web services were down for some period of time and as a result this tool wasn't operational, resulting in timeout error. USGS web services are now operational so this tool should work as expected. 1908 S Sullivan St, Santa Ana, CA 92704, USA Latitude, Longitude: 33.721997, -117.905265 Date 5/28/2024, 12:37:46 AM Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Default (See Section 11.4.3) Type Value Description SS 1.303 MCER ground motion. (for 0.2 second period) S1 0.466 MCER ground motion. (for 1.0s period) SMS 1.563 Site-modified spectral acceleration value SM1 null -See Section 11.4.8 Site-modified spectral acceleration value SDS 1.042 Numeric seismic design value at 0.2 second SA SD1 null -See Section 11.4.8 Numeric seismic design value at 1.0 second SA Type Value Description SDC null -See Section 11.4.8 Seismic design category Fa 1.2 Site amplification factor at 0.2 second Fv null -See Section 11.4.8 Site amplification factor at 1.0 second PGA 0.557 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.668 Site modified peak ground acceleration TL 8 Long-period transition period in seconds SsRT 1.303 Probabilistic risk-targeted ground motion. (0.2 second) SsUH 1.411 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 1.683 Factored deterministic acceleration value. (0.2 second) S1RT 0.466 Probabilistic risk-targeted ground motion. (1.0 second) S1UH 0.505 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration. S1D 0.6 Factored deterministic acceleration value. (1.0 second) PGAd 0.69 Factored deterministic acceleration value. (Peak Ground Acceleration) 5/28/24, 12:39 AM U.S. Seismic Design Maps https://www.seismicmaps.org 1/3 1908 S Sullivan St - 201833137/30/2024 BWU Consultants, Inc. 1168 N. San Gabriel Blvd., #N Rosemead, CA. 91770 Tel: (626) 288-0708 Email: twengrs1168@gmail.com Date: SEISMIC DESIGN 2022 CALIFORNIA BUILDING CODE CITY OF L.A. BUILDING CODE COUNTY OF L.A. BUILDING CODE SDS = SMS = FASS =(1.2)*(1.303)=1.042 SD1 = SM1 = FVS1 =(1.5)*(0.466)=0.466 LATITUDE: 33.721997 PROJECT LOCATION: 1908 S Sullivan St, Santa Ana, CA 92704, USA LONGITUDE: -117.905265 SITE CLASS: D (Class D is selected without Soils Report) 2 3 2 3 2 3 2 3 2 3 2 3 1908 S Sullivan St - 201833137/30/2024 BWU Consultants, Inc. 1168 N. San Gabriel Blvd., #N Rosemead, CA. 91770 Tel: (626) 288-0708 Email: twengrs1168@gmail.com Date: ASCE 7-16 FP =0.3 SDS IP WP 1.6 SDS IP WP CS =0.7 FP CSW =0.7 x 0.66 W = 0.462 / 1.4 = 0.33 W AND SECTION 13.3 OF ASCE 7-16 0.4 AP SDS ( RP / IP ) AP = 1.0 RP = 2.5 z/h = 1.0 FP = ENCHARGE10 WALL MOUNTED BRACKET WT = 341 LB EXISTING 2X4 STUD Ht= 8'-0" Pall = 600 LB VERTICAL LOAD WIND SEISMIC ∇= 0.50 x 341 LB 170.5 LB / 3-1/4"Ø screws = 57 LB 225 LB OK 210 LB OK SEISMIC DEMAND ON NONSTRUCTURAL COMPONENTS (ELEMENTS) 0.4 x 1.0 x 1.04 2.5 FP =WP (1+2 z/h) x (1+2x1) WP =0.50 WP 57 LB < (3-1/4"Ø x 1 1/2 " MIN. EMBED) = 24.92 PSF x 24"x32"/ 12"x12" = 133 LB C=T: 133x6"/6" = 133 LB / 3 LAG SCREWS = 44.3 LB < 225 LB WITHDRAW OK 341 LB / 3 SUPPORTS = 113.7 LB / LAG SCREW < 210 LB OK 𝛻 𝛻 1908 S Sullivan St - 201833137/30/2024 1908 S Sullivan St - 201833137/30/2024 1908 S Sullivan St - 201833137/30/2024 1908 S Sullivan St - 201833137/30/2024 To Whom it may concern, This letter is to certify that I have contracted with and authorize Semper Solaris to submit permit and install a ESS system on our home at 1908 S Sullivan St Santa Ana CA 92704. Thank you, Leticia Silva DocuSign Envelope ID: 24019B32-945C-40F2-A3E2-8B1702679FC0 1908 S Sullivan St - 201833137/30/2024 Certificate Of Completion Envelope Id: 24019B32945C40F2A3E28B1702679FC0 Status: Completed Subject: Complete with Docusign: Santa Ana- HO authorization.pdf Change Order: Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 4 Initials: 0 Permits LA AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 1805 John Towers Avenue El Cajon, CA 92020 permits.la@sempersolaris.com IP Address: 49.36.33.87 Record Tracking Status: Original 5/31/2024 10:44:18 AM Holder: Permits LA permits.la@sempersolaris.com Location: DocuSign Signer Events Signature Timestamp Leticia Silva letyshernandez5214@gmail.com Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 13.58.97.123 Signed using mobile Sent: 5/31/2024 10:49:55 AM Viewed: 5/31/2024 11:31:14 AM Signed: 5/31/2024 11:31:27 AM Electronic Record and Signature Disclosure: Accepted: 5/31/2024 11:31:14 AM ID: 0751dd3e-60b4-41f7-ace3-cde0f281fcda In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 5/31/2024 10:49:55 AM Certified Delivered Security Checked 5/31/2024 11:31:14 AM Signing Complete Security Checked 5/31/2024 11:31:27 AM Completed Security Checked 5/31/2024 11:31:27 AM Payment Events Status Timestamps Electronic Record and Signature Disclosure 1908 S Sullivan St - 201833137/30/2024 ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, Semper Solaris (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to this Electronic Record and Signature Disclosure (ERSD), please confirm your agreement by selecting the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after the signing session and, if you elect to create a DocuSign account, you may access the documents for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. Further, you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Electronic Record and Signature Disclosure created on: 12/8/2021 9:55:02 AM Parties agreed to: Leticia Silva 1908 S Sullivan St - 201833137/30/2024 Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. How to contact Semper Solaris: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: order@sempersolaris.com To advise Semper Solaris of your new email address To let us know of a change in your email address where we should send notices and disclosures electronically to you, you must send an email message to us at Order@sempersolaris.com and in the body of such request you must state: your previous email address, your new email address. We do not require any other information from you to change your email address. If you created a DocuSign account, you may update it with your new email address through your account preferences. To request paper copies from Semper Solaris To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an email to order@sempersolaris.com and in the body of such request you must state your email address, full name, mailing address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with Semper Solaris To inform us that you no longer wish to receive future notices and disclosures in electronic format you may: 1908 S Sullivan St - 201833137/30/2024 i. decline to sign a document from within your signing session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an email to order@sempersolaris.com and in the body of such request you must state your email, full name, mailing address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found here: https://support.docusign.com/guides/signer-guide- signing-system-requirements. Acknowledging your access and consent to receive and sign documents electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please confirm that you have read this ERSD, and (i) that you are able to print on paper or electronically save this ERSD for your future reference and access; or (ii) that you are able to email this ERSD to an email address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format as described herein, then select the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. By selecting the check-box next to ‘I agree to use electronic records and signatures’, you confirm that:  You can access and read this Electronic Record and Signature Disclosure; and  You can print on paper this Electronic Record and Signature Disclosure, or save or send this Electronic Record and Disclosure to a location where you can print it, for future reference and access; and  Until or unless you notify Semper Solaris as described above, you consent to receive exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you by Semper Solaris during the course of your relationship with Semper Solaris. 1908 S Sullivan St - 201833137/30/2024                               ! !       "   #$  !   %   !&'   ( )* %$+ , , - #$  )  (  )* . (  )*     !     / "!  &     "     ! &     ")0 !  1 &    "      / 234!! /     & !  &      5!         6   !     789:;<=> ?*  234!!   @A24 / ?%!&     & /  0 "     "(  )* ?!  1 &  2% (. B   C:>DEF>: ?,)   /  ?   /     "  ?# / ! " "       ?GHIJKLMNMOPKQJRLNJSINTRUQJRLN   VDWX>: ?Y!  &      ?        ?$!  ( !$ "  !  " ! Z.[#\ ?]^LRMN_OULOQSLRMNRLUOKLN     "     ?Y    &   VE<: ?.   #`a)3    !     " &   "  ?# !    Z`Y*\    "  1! "     bcdcefghhd ,)     /  ic %   a2 )),22 .   (! &   jkhlmnmicko pqrstuvw xyz{|}y~ qV€ ‚ (  )* nƒbhl„i…n†hk (..‡ˆ )* ,* -. (  )*   /  B    &        Z(B$\/ &     ‰gcdŠf„mi„dgh„†ƒ‹ (  )*!(  )*!Z() . #$ , \ %  !  (  )* //! "  "       " ! (! &      (! &  " ! &   / [    5! " #`a)3 B)    / ./B)    / "  !  &  !&&   B3 !   / ./B3 !   /  !   &/  !&   B)%  !   / ./B)%  !   / " BB 5!    &  Œ ŽN J ‘LNK LMNPORNML ’R S“NTL‘IN J ‘LMNKONK_LN’S K .‡`  $ .‡`  /!   " .‡`/  .‡`  /   $ .‡`  /   " .‡`/  !  ”! Z”\”"   ! (  !    ƒjdmƒicl„c••hffƒkmhf„cib„khjlc•hnhid„jckdf 2% (. ‡B–—˜™š›œšNž RO SŸLRKLRNPORNTL‘INRLH‘J LULSK () . #$ ,  ‡B–—N›JKKLR N¡¢N›JKKLR N’S KNPORNTL‘INRLH‘J LULSK () £ )) [–—N›JKKLR N¡¢N OŸLRNPORNTL‘INRLH‘J LULSK () * )) [(  )*   ! () * aA [–—N›JKKLR N¡¢N OSI’ KNH‘JKLMNPORNTL‘INRLH‘J LULSK¤N–S ‘’ILMNOSLN‘LPKšM ILNJSINOSLNR “_KšM ILN OSI’ KNH‘JKL () 0( )3 [–—N›JKKLR N¡¢NQJ‘‘N RJ ¥LKNPORNTL‘INRLH‘J LULSK¤N–S ‘’ILMNOSLNQJ‘‘šUO’SKN RJ ¥LKNJSINOSLNKOHNM_ L‘I (..‡ˆ +-%` )(  )*"   !   "        "   () Y( 2 [–—N›JKKLR N¡¢Nœ¦NT‘KLRN OJRINPORNTL‘INRLH‘J LULSK () (B$- 3a [–—N›JKKLR N¡¢N›žŒN OJRINPORNTL‘INRLH‘J LULSK () -( A [–—N›JKKLR N¡¢N OSKRO‘N OUU’S JK OSN OJRINPORNTL‘INRLH‘J LULSK () -$ )3 [() -#$ )3 [ –—N›JKKLR N¡¢N OSKRO‘NMQ K _NHRL SMKJ‘‘LINOSNK_LNQ R S“N OŸLRNPORNTL‘INRLH‘J LULSK ƒ…dj…d„§c•¨©ª«¬„­c•® ‡  Z!! \!!/ 234 * !!/ @A24Z  \A,34Z,  \ -  ‡  3,, A34 - " 5! ‡  A)@ A+6 ‡  !!! Z¯34\ ,A * !!! Z¯34\ Z  \)AZ,  \ */ "  Z '!  & \2)  2)  B 1!!! !     !   $   œ¦NRO’SIšKR HNL° LS  a±    `!    Z`Y*\ ! #)  Z2" \ B! 0  !     !Z    \ ,Œ’HHORKLIN SN OK_N“R Iš OSSL KLINJSIN J ¥’H²O^š“R INOHLRJK OS  &   )±/   ( )* %$+ , , - #$  )  1908 S Sullivan St - 201833137/30/2024        !"#$%&'(")*!+,-)+%-./01 234567890:; <=3>35678:0?; @34483>48A848B CDE6 E6AC?EFGDDEFB44C4H448 @34483>48AH848B CDE6 E6AC?EFGIGEFB44C4H448 J3>3483>48 E6IE6AIDEF:0EFB 63K>34AKF B LMN OPM QRS 5344AT==5B/:33= 33=G::33AI:04=DG94=9?4B KU48V800I8AG?0GB 4HV89:/8AG9?B W4>J>HX2W<@IY :5C@<474> 2W<@0 648 2>474 Z [\R OSRM]L^QP OM 6363V4H<_<47`_364IaIb`634 a 6` bVU8HCH4H>4 633>44 H433>44 _7>`_UC64>34`J`4H2W<48 <448 W44 U34HW4@34484c@ 484 634 6@Y>DGAKG9?GC_@B`WWWG ?9dDG:AKG9?GC_`IHWHB 6@2a6_@6DDD2G9GCG0 K/ ?`K/ ?@`2I:I`KG//:`K//G`2W<@IY`@6G 0 W<d?96FY` G `6`6W_I 6<H>dKG/9I`2I:I 47dK0DG/CG`W60DG/CD QPLP SRe  O  K3HV4f01`>G 0`g Ihi)-i+j+"!#--$"k!l"k(m!n+k(")-()#%k!o**p. C C5_TCGCGCW2C_CDDIC CDD qDDIW4W48@87HW4`4H668``4H43H daa43aH3C>8C8>H4H3UW4W48`44_4H>4 5>r48 Y74 sP\P]O S  S\MP^ P]O 5_TCGCG <DDI 4 C C5_TCGCGCW2C_CDDIC CDD 1908 S Sullivan St - 201833137/30/2024 1908 S Sullivan St - 201833137/30/2024 1908 S Sullivan St - 201833137/30/2024 1908 S Sullivan St - 201833137/30/2024 1908 S Sullivan St - 201833137/30/2024 1908 S Sullivan St - 201833137/30/2024 17 Switching Configurations Type 2-pole 2-pole 4 parallel poles 4-pole 2-pole 4 poles in series Input on top Output bottom 2-pole 4 poles in series Input and Output bottom 2-pole 4 poles in series Input and Output on top SI16 2 2H 4 4S 4T 4B SI25 2 2H 4 4S 4T 4B SI32 2 2H 4 4S 4T 4B SI40 2 2H 4 4S 4T 4B SI55 2 2H 4 4S 4T 4B Contacts Wiring Diagram Switching example 2 4 1 3 + - 2 4 1 3 6 8 5 7 + - 2 4 1 3 6 8 5 7 + -- + 2 4 1 3 6 8 5 7 + - 2 4 1 3 6 8 5 7 + - 2 4 1 3 6 8 5 7 + - Type 6-pole 2-pole 6 parallel poles 8-pole 2-pole 8 parallel poles SI16 6 3H 8 4H SI25 6 3H 8 4H SI32 6 3H 8 4H SI40 - - - - SI55 - - - - Contacts Wiring Diagram Switching example 2 4 1 3 6 8 5 7 2 4 1 3 2 4 1 3 6 8 5 7 2 4 1 3 2 1 4 3 6 5 8 7 4 3 6 5 8 7 2 1 2 1 4 3 6 5 8 7 4 3 6 5 8 7 2 1 + -+ -+ - +- + + + +- - - - +- Insulated Jumper for series and parallel switching of contacts Type Jumper Pack Weight SI16, SI25, SI32 SIV-B1 100 6.6g/pc. SI40, SI55 SIV-B2 100 9.64g/pc. Specifications are subject to change without notice 26 Specifications are subject to change without notice Rotary Actuator Switch - Lockable Off in Plastic Enclosure Rotary Actuator Switch Lockable Off - Safe-Lock Self-Extinguishing Plastic Enclosure M25 Cable Gland Entry Option NEMA Type 3R IP66 „ „ „ „ „ „ DC21A IEC60947-3 UL Ratings UL508i Poles in series No. of Strings Weight Kg/pcs. Part Number Contact Configuration600V 800V 1000V 1500V 350V 500V 600V 1000V 16A 16A 9A 3A 16A 16A 16A - 2 1 0.43 SI16 PEL64R 2 25A 20A 11A 4A 20A 20A 20A - 2 1 0.43 SI25 PEL64R 2 32A 23A 13A 5A 25A 25A 25A - 2 1 0.43 SI32 PEL64R 2 40A 30A 20A 6A 40A 40A 40A 16A 2 1 1.59 SI40 PEL64R 2 55A 45A 36A* 8A 55A 55A 55A 20A 2 1 1.59 SI55 PEL64R 2 29A 16A 9A 3A 29A 29A 21A - 2 1 0.49 SI16 PEL64R 2H 45A 20A 11A 4A 45A 38A 23A - 2 1 0.49 SI25 PEL64R 2H 50A 23A 13A 5A 58A 40A 25A - 2 1 0.49 SI32 PEL64R 2H 64A 30A 20A 6A 72A 53A 42A 22A 2 1 1.74 SI40 PEL64R 2H 80A 45A 25A 8A 85A 66A 55A 25A 2 1 1.74 SI55 PEL64R 2H 16A 16A 9A 3A 16A 16A 16A - 2 2 0.46 SI16 PEL64R 4 25A 20A 11A 4A 20A 20A 20A - 2 2 0.46 SI25 PEL64R 4 32A 23A 13A 5A 25A 25A 25A - 2 2 0.46 SI32 PEL64R 4 40A 30A 20A 6A 40A 40A 40A 16A 2 2 1.67 SI40 PEL64R 4 55A 45A 36A* 8A 55A 55A 55A 20A 2 2 1.67 SI55 PEL64R 4 16A 16A 16A 16A 16A 16A 16A - 4 1 0.47 SI16 PEL64R 4S 25A 25A 25A 20A 25A 25A 25A - 4 1 0.47 SI25 PEL64R 4S 32A 32A 32A 23A 32A 32A 32A - 4 1 0.47 SI32 PEL64R 4S 40A 40A 40A 30A 40A 40A 40A 40A 4 1 1.70 SI40 PEL64R 4S 55A 55A 55A 40A 55A 55A 55A 55A 4 1 1.70 SI55 PEL64R 4S 16A 16A 9A 3A 16A 16A 16A - 2 3 1.53 SI16 PEL64R 6 25A 20A 11A 4A 20A 20A 20A - 2 3 1.53 SI25 PEL64R 6 32A 23A 13A 5A 25A 25A 25A - 2 3 1.53 SI32 PEL64R 6 16A 16A 9A 3A 16A 16A 16A - 2 4 1.58 SI16 PEL64R 8 25A 20A 11A 4A 20A 20A 20A - 2 4 1.58 SI25 PEL64R 8 32A 23A 13A 5A 25A 25A 25A - 2 4 1.58 SI32 PEL64R 8 29A 29A 29A 16A 29A 29A 29A - 4 1 1.63 SI16 PEL64R 4H 45A 45A 45A* 20A 45A 45A 45A - 4 1 1.63 SI25 PEL64R 4H 58A 58A* 58A* 23A 58A 58A 50A - 4 1 1.63 SI32 PEL64R 4H 2 4 1 3 2 4 1 3 6 8 5 7 2 4 1 3 6 8 5 7 2 4 1 3 6 8 5 7 2 1 4 3 6 5 8 7 4 3 6 5 8 7 2 1 2 1 4 3 6 5 8 7 4 3 6 5 8 7 2 1 2 4 1 3 6 8 5 7 2 4 1 3 4T / 4B configuration also available. For ratings refer to 4S configuration. (See page 17) * DC21B 1908 S Sullivan St - 201833137/30/2024 27Specifications are subject to change without notice Technical Data Data according to IEC 60947-3, VDE 0660, GB14048.3 1) Suitable at overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 8kV. 2) Suitable at overvoltage category I to III, pollution degree 2 (min.IP55): Uimp = 8kV. Main Contacts Type SI16 SI25 SI32 SI40 SI55 Rated thermal current Ithe A 16 25 32 40 55 Rated insulation voltage Ui 1)V 1000 1000 1000 1500 1500 Rated insulation voltage Ui 2)V 1500 1500 1500 - - Distance of contacts (per pole) mm 8 8 8 Rated operational current Ie 300V A 16 23 27 40 55 1 pole 400V A 12 14 16 30 40 DC21A & DC21B 1 500V A 9 11 13 19 25 600V A 6 8 10 15 20 700V A 4.5 6 7.5 10 15 L/R = 1ms 800V A 3 4 5 8 10 900V A 2.5 3 4 6 8 DC21B 1000V A 1.5 2 2.5 4 6 2 poles in series 500V A 16 25 32 40 55 2 600V A 16 25 32 40 55 700V A 16 23 27 35 55 800V A 16 20 23 30 45 850V A - - 25 - - 900V A 13 16 20 25 35 1000V A 9 11 13 20 36 1200V A 6 8 10 10 15 1500V A 3 4 5 6 8 2 poles in series 500V A 29 45 58 72 85 + 2 poles parallel 600V A 29 45 50 64 80 2H 700V A 16 23 27 35 55 800V A 16 20 23 30 45 900V A 13 16 20 25 35 1000V A 9 11 13 20 25 1200V A 6 8 10 10 15 1500V A 3 4 5 6 8 3 poles in series 500V A 29 45 58 - - + 2 poles parallel 600V A 29 45 50 - - 3H 700V A 29 38 45 - - 800V A 29 38 45 - - 900V A 29 38 45 - - 1000V A 29 38 45 - - 1200V A 12 14 16 - - 1500V A 9 11 13 - - 4 poles in series 500V A 16 25 32 40 55 4S 600V A 16 25 32 40 55 700V A 16 25 32 40 55 800V A 16 25 32 40 55 900V A 16 25 32 40 55 1000V A 16 25 32 40 55 1200V A 16 25 32 40 55 1500V A 16 20 23 30 40 4 poles in series 500V A 29 45 58 - - + 2 poles parallel 600V A 29 45 58 - - 4H 700V A 29 45 58 - - 800V A 29 45 58 - - 900V A 29 45 58 - - 1000V A 29 45 58 - - 1200V A 29 45 50 - - 1500V A 16 20 23 - - Rated operational current Ie AC21B 2, 4 Ue max. 440V A 16 25 32 40 55 2H Ue max. 440V A 29 45 58 72 85 1 2 1 2 3 4 1 2 3 4 1 2 3 4 5 6 7 8 1 1 2 3 4 5 6 28 Specifications are subject to change without notice Technical Data continued Data according to IEC 60947-3, VDE 0660, GB14048.3 Main Contacts Type SI16 SI25 SI32 SI40 SI55 Rated operational current Ie 500V A 1 1.25 1.5 x 2.5 DC22B 1 pole 600V A 0.5 0.75 1 x 2 1 800V A 0.3 0.4 0.5 x 1.5 L/R = 2.5ms 1000V A 0.15 0.2 0.25 x 1 1200V A - - - x x 1500V A - - - x x 2 poles in series 500V A 7 8 9 x x 2 600V A 5.5 6 6.5 x x 800V A 2 2.5 3 x x 1000V A 1 1.5 2 x x 1200V A - - - x x 1500V A - - - x x 4 poles in series 500V A 16 25 32 x x 4S 600V A 16 25 27.5 x x 800V A 11.5 12 12.5 x x 1000V A 8 9 10 x x 1200V A - - - x x 1500V A - - - x x Rated conditional short-circuit current kAeff 5 5 5 10 10 Max. fuse size gL (gG) A 40 63 80 125 160 Mechanical Life x103 10 10 10 10 10 Rated short-time withstand current (1s) Icw 2, 4, 6, 8 2H, 3H, 4H A A 800 1300 900 1500 1000 1700 A2, A4: 1200 A2+2: 2000 A2, A4: 1400 A2+2:2400 Short circuit making capacity Icw 2, 4, 6, 8 2H, 3H, 4H A A 800 1300 900 1500 1000 1700 A2, A4: 1200 A2+2: 2000 A2, A4: 1400 A2+2:2400 Maximum cable cross sections (including jumper LSV-B1) solid or stranded mm2 4 - 16 4 - 16 4 - 16 2.5 - 25 2.5 - 25 flexible mm2 4 - 10 4 - 10 4 - 10 4 - 16 4 - 16 flexible (+ multicore cable end) mm2 4 - 10 4 - 10 4 - 10 2.5 - 16 2.5 - 16 Size of terminal screw M4 Pz2 M4 Pz2 M4 Pz2 M5 Pz2 M5 Pz2 Tightening torque Nm 1.2 - 1.8 1.2 - 1.8 1.2 - 1.8 2.5 - 2.8 2.5 - 2.8 2 cables per clamp without jumper LSV-B1 / LSV-B2 solid or stranded mm2 16+(1.5-2.5)/10+(1.5-6)/6+(1.5-10)/4+(1.5-10) 16+(1.5-2.5)/10+(1.5-10)/ 6+(1.5-10)/4+(1.5-10) flexible mm2 16+(1.5-2.5)/10+(1.5-4)/6+(1.5-6) 16+(1.5-6)/10+(1.5-10)/ 6+(1.5-16)/4+(1.5-16)& flexible + multicore cable end stranded AWG 8+(16-12)/10+(16-10)/12+(16-8)/14+(16-8) 3+(18-10)/4+(18-10)/ 6+(18-8)/8+(18-8) solid AWG 10+(16-12)/12+(16-10)/14+(16-10) 10+(16-10)/12+(16-10)/ 14+(16-10)/12+(16-10)/14+(16-10) Maximum ambient temperature Operation All types except PEL64R °C -40 to +65 PEL64R type °C -40 to +45 Storage °C -50 to +70 Power loss per switch at Ie max. DC21B 2 W 0.8 2 3 4 6 4 W 1.6 4 6 8 12 6 W 2.4 6 9 12 18 8 W 3.2 8 12 16 24 2H W 0.4 1 1.5 2 3 3H W 0.6 1.5 2.25 3 4.5 4H W 0.8 2 3 4 6 1 2 1 2 3 4 1 x - In Test 1908 S Sullivan St - 201833137/30/2024 1908 S Sullivan St - 201833137/30/2024 Iii\ Semper Sol.aris December 7,2023 To Whom it may concern, This letter hereby authorizes the following personnel to sign and pay for any and all building permits and city licenses required by Semper Solaris in the Counties of San Bernardino, Riverside, San Diego, Los Angeles, Bay Area and any municipalities that fall within those counties for a period of 12 months from December 7, 2023. Estephany Arreola Rachael Williams Krikor Karamanoukian Chinmayee Rupade Amanda Phillips Taros Onanian Alexis Herrera Archon Energy Solutions Serzhik Akopyan Jaime Contreras I-Permit Lorena Hernandez Rapid Duct Testing Daniel Keshishyan Michael Ybarra Shruti Shetty Ketan Mavle Vyankatesh Barde Mike Torosyan Philemon Sigei Saro Jankozian Veronica Mosqueda Serj Jankozian Matthew Cavner Olga Ani Buniatyan CA License No. 978152 B, C-10, C-20, C-39, C-46 Expiration Date 10/31/2024 Federal Tax Id #45-5089569 State Tax ID #3460732 Workman's Comp Carrier: Midwest Employers Casualty Company Policy Number: BNUWC0161073 Expiration Date 10/10/2024 Angel Rodarte RME 714-423-7363 h \�RMt \�� l'l-/11/zoz_� Semper Solaris • 1805 John Towers Avenue, El Cajon 92020 • 619-715-4054 1908 S Sullivan St - 201833137/30/2024 1908 S Sullivan St - 201833137/30/2024