HomeMy WebLinkAbout1901 W Hall Ave - Plan1226 W. NINTH ST. UPLAND, CA 91786 310.487.1613 HELLO@DREAMDESIGN.BUILD DREAMDESIGN.BUILD OWNER: JUAN CAMACHO ADDRESS: 1901 W HALL AVE SANTA ANA, CA 92704 SCOPE OF WORK: (E) GARAGE WALLS TO BE DRYWALLED (NO NEW INSULATION) (N) EXTERIOR WATER HEATER ENCLOSURE (TO MATCH EXISTING HOME) (E) COVERED PATIO & SHED TO BE REMOVED. UNPERMITED ELECTRICAL AND PLUMBING WORK TO BE REMOVED FROM GARAGE UNPERMITED DRYWALL TO BE REMOVED FROM GARAGE CEILING PLANS PREPARED BY: RESTRICTIVE NOTICE: ALL DESIGNS, IDEAS, DETAILS, PLANS & SPECIFICATIONS INDICATED BY THE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF DDB,LLC. THE PLANS WERE CREATED AND DEVELOPED FOR USE ON AND IN CONJUNCTION WITH THE SPECIFIC PROJECT DESCRIBED HEREIN. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, MODIFIED OR DISTRIBUTED TO OTHERS WITHOUT PRIOR WRITTEN AND SPECIFIC CONSENT FROM DDB, LLC. PROJECT INFO A0.0 SCALE: DRAWN: CHECKED: DATE: REVISION: REVISION: EDGAR VIDAL 9/18/24 AS SHOWN E. VIDAL A0.0 A1.0 A2.1 A2.2 A2.3 A3.0 A4.0 A5.0 GB1.1 GB1.2 S1 S2 S3 S4 PROJECT INFO EXISTING & PROPOSED SITE PLANS EXISTING FLOOR PLAN EXISTING ROOF PLAN EXISTING ELEVATIONS PROPOSED FLOOR PLAN PROPOSED ELEVATIONS SECTIONS GREEN BUILDING GREEN BUILDING FOUNDATION PLAN FRAMING PLAN WOOD FRAME PRESCRIPTIVE PROVISIONS PRESCRIPTIVE STRUCTURAL DETAILS SHEET INDEX VICINITY MAP 1. THE METHOD OF CLEARING AND STRIPPING SHOULD BE VERIFY BY THE CONTRACTOR. 2. ALL SURFACE VEGETATION, DEBRIS AND STRUCTURES TO BE DEMOLISHED SHALL BE REMOVED FROM THE SITE PRIOR TO COMMENCING SITE PREPARATION, EXCAVATION OR PLACEMENT FILL. 3. FILL FOR FLOOR SLABS AND FOUNDATION TRENCHES SHALL CONSIST OF NATIVE SOIL. 4. NATIVE SOIL PLACED FOR SLAB SUPPORT SHALL BE PLACED IN LAYERS NOT EXCEEDING 4" WHEN COMPACTED. 5. IMPORT FOR SLAB SUPPORT SHALL CONSIST OF SAND, GRAVELY SAND OR SILTY SAND AND SHALL HAVE A EXPANSION INDEX OF LESS THAN 30. 1. ALL WORK SHALL COMPLY WITH THE 2022 CALIFORNIA BUILDING CODE, TITLE 24 AND ALL APPLICABLE CODES, REGULATIONS OR REQUIREMENTS OF THE CITY OR COUNTY HAVING JURISDICTION FOR THE PLACE OF THE BUILDING. 2. PERMITS SHALL BE OBTAINED FOR FENCES, POOLS, SPA OR RETAINING WALLS. 3. FINAL GRADING WORK SHALL COMPLY WITH 2019 CBC AND SHALL PROVIDE POSITIVE DRAINAGE FROM ALL PARTS OF THE BUILDING AND SHALL NOT DRAIN ONTO ADJACENT PROPERTIES. 4. ALL SURFACES SHALL BE SLOPED TO DRAIN WATER AWAY FROM THE BUILDING. 5. AT TIME OF PERMIT ISSUANCE, THE CONTRACTOR SHALL SHOW THEIR VALID "WORKERS COMPENSATION" INSURANCE CERTIFICATE. 6. ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF THE INFORMATION INDICATED ON THESE PLANS. 7. BUILDING ADDRESS NUMBERS SHALL BE PROVIDED ON THE FRONT OF ALL BUILDINGS AND SHALL BE VISIBLE AND LEGIBLE FROM THE STREET FRONTING THE PROPERTY, SAID NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. 1. ROOF OBSTRUCTIONS SUCH AS TELEVISION ANTENNA, GUY WIRES, SOLAR PANELS, RAZOR RIBBON FENCE, CABLE OR OTHER OBSTRUCTIONS SHALL NOT PREVENT FIRE DEPARTMENT ACCESS OR EGRESS IN THE EVENT OF FIRE. 2. PROVIDE COLLISION BARRIERS ADEQUATE TO PROTECT CONTROL METERS, REGULATORS AND PIPING FOR HAZARDOUS MATERIALS THAT ARE EXPOSED TO VEHICULAR DAMAGE LAMC 57.12.02. 3. THE INDOOR STORAGE OF COMBUSTIBLE MATERIALS SHALL BE REGULATED IN RELATION TO ARRANGEMENT, LOCATION, SIZE OF AREAS, HEIGHT SEPARATIONS AND HOUSEKEEPING. 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF THE JOB SITE BEFORE STARTING ANY WORK AND BE RESPONSIBLE FOR THE SAME, THE ARCHITECT SHALL BE NOTIFY OF ANY DISCREPANCIES WHICH MAY EXIST. CONTRACTOR SHALL NOT SCALE ANY DRAWINGS. 2. THE SPECIFICATIONS ARE OF A GENERAL NATURE AND MAY REFER TO WORK WHICH IS NOT REQUIRED. THEY ARE NOT INTENDED TO SUPERSEDE ANY CONTRACTUAL AGREEMENT BETWEEN THE OWNER AND THE CONTRACTOR. 3. THE CONTRACTOR SHALL PROVIDE SUPERVISION TO PROPERLY EXECUTE THE PROJECT AND TO PROVIDE ASSURANCE THE WORK IS IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. 4. ALL NECESSARY PERMITS SHALL BE SECURED BY THE CONTRACTOR PRIOR TO START ANY CONSTRUCTION. A. AT THE TIME OF ROUGH INSTALLATION, OR DURING STORAGE ON THE CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING, AND VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL, OR OTHER ACCEPTABLE METHODS TO REDUCE THE AMOUNT OF WATER, DUST, AND DEBRIS WHICH MAY ENTER THE SYSTEM. B. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHALL NOT BE INSTALLED. WALL AND FLOOR FRAMING SHALL NOT BE ENCLOSED WHEN THE FRAMING MEMBERS EXCEED 19% MOISTURE CONTENT. INSULATION PRODUCTS WHICH ARE VISIBLE WET OR HAVE HIGH MOISTURE CONTENT SHALL BE REPLACED OR ALLOWED TO DRY PRIOR TO ENCLOSURE IN WALL OR FLOOR CAVITIES. C. ALL MECHANICAL EXHAUST FANS IN ROOMS WITH A BATHTUB OR SHOWER SHALL COMPLY WITH THE FOLLOWING: - FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMITE OUTSIDE THE BUILDING. - FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF < 50% TO A MAXIMUM OF 80% UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM. 1. PROVIDE 72 INCH HIGH NONABSORBENT WALL ADJACENT TO SHOWER, AND APPROVED SHATTER RESISTANT MATERIALS FOR SHOWER. 2. ONLY LOW CONSUMPTION WATER CLOSETS SHALL BE PROVIDED. "PROVIDE ULTRA FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION." 3. ENCLOSED USABLE SPACE UNDER INTERIOR STAIRWAYS REQUIRES 1-HOUR FIRE RESISTIVE CONSTRUCTION ON ENCLOSED SIDE. 4. EXIT DOORWAYS SHALL BE NOT LESS THAN 36" X 6'-8" (WIDTH AND HEIGHT). PROJECTIONS INCLUDING PANIC HARDWARE, SHALL NOT REDUCE THE OPENING TO LESS THAN 32" CLEAR WIDTH. 5. PROVIDE 32" WIDE DOORS TO ALL ACCESSIBLE ROOMS WITHIN A DWELLING UNIT. 6. GLASS SKYLIGHTS SHALL COMPLY WITH 91.2409. PLASTIC SKYLIGHTS WITH 91.1006.12 7. PROVIDE WINDOW WELLS (WITH FIXED LADDER) FOR EGRESS WINDOWS BELOW GRADE. 8. WATER HEATER IS REQUIRED TO BE ANCHORED. "WATER HEATER MUST BE STRAPPED TO WALL." 9. PROVIDE ACCESS TO THE BOTTOM OF COURT FOR CLEANING PURPOSES. 10. COURT MORE THAN TWO STORIES IN HEIGHT SHALL BE PROVIDED WITH A HORIZONTAL AIR INTAKE WITH A MINIMUM AREA OF 10 SQ.FT. 1. WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED EQ. WITHIN 72" ABOVE DRAIN. 2. MATERIALS OTHER THAN STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT MATERIALS: 3. GLASS ENCLOSURE DOORS MUST BE LABELED CATEGORY II SWING DOOR OUTWARD. 4. NET AREA OF SHOWER RECEPTOR NOT LESS THAN 1024 " OR 30" DIA CIR 510, 511, 5406, 5407, UBC STD. T-54 & D.C. 909. 5. BATHS WITHOUT OPENABLE WINDOWS SHALL BE PROVIDED WITH VENT FAN CAPABLE OF MINIMUM 5 AIR CHANGES PER HR. 6. TOILET COMPARTMENT MINIMUM 30" WIDE WITH 24" CIR. IN FRONT OF TOILET. 7. PROVIDE MINIMUM 12" X 12" ACCESS AT TUB TRAP EXCEPT WHERE CONCERNED FIXED CONNECTIONS ARE OF BRASS & WITHOUT SLIP JOINTS. 8. PROVIDE MECHANICAL VENTILATION CONNECTED DIRECTLY TO THE OUTSIDE CAPABLE OF PROVIDING FIVE A/P CHANGES PER HOUR IN BATHROOMS, WATER CLOSET COMPARTMENTS, LAUNDRY ROOMS, AND SIMILAR ROOMS IF REQUIRED OPENABLE WINDOWS ARE NOT PROVIDED SITE PREPARATION SITE NOTES SPECIAL HAZARDS MISCELLANEOUS BUILDING CODE NOTES FINISH MATERIAL POLLUTANT CONTROL MATERIAL CONSERVATION & RESOURCE EFFICIENCY ENVIRONMENTAL QUALITY INTERIOR BATH A. ADHESIVE, SEALANTS AND CAULKS SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN SECTION 4.504.2.1 AND COMPLY WITH THE VOC LIMITS IN TABLES 4.504.1 AND 4.504.2 AS APPLICABLE. B. PAINTS AND COATINGS SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN SECTION 4.504.2.2. AND COMPLY WITH THE VOC LIMITS IN TABLE 4.504.3. C. AEROSOL PAINTS AND COATINGS SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN SECTION 4.504.2.3 D. ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT REQUIREMENTS OF ONE OF HE FOLLOWING: I. CARPET AND RUG INSTITUTE'S GREEN LABEL PLUS PROGRAM OR II. CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD METHODS FOR THE TESTING OF VOC EMISSIONS (SPEC 01350) OR III. NSF/ANSI 140 AT THE GOLD LEVEL OR IV. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE GOLD E. ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL PROGRAM. CARPET ADHESIVES SHALL NOT EXCEED A VOC LIMIT OF 50 G/L. (4.504.3.1, 4.504.3.2) F. A MINIMUM OF 80% OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OR MORE OF THE FOLLOWING: I. PRODUCTS CERTIFIED AS A LOW-EMITTING MATERIAL IN THE CHPS HIGH PERFORMANCE PRODUCTS DATABASE OR II. PRODUCTS CERTIFIED UNDER UL GREEN GUARD GOLD (FORMERLY THE GREEN GUARD CHILDREN & SCHOOLS PROGRAM), OR III. CERTIFICATION UNDER THE RFCI FLOORSCORE PROGRAM OR IV. MEET THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD METHOD FOR THE TESTING OF VOC EMISSIONS (SPEC 01350) G. COMPOSITE WOOD PRODUCTS (HARDWOOD PLYWOOD, PARTICLE BOARD, AND MDF) INSTALLED ON THE INTERIOR OR EXTERIOR OF HE BUILDING SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN TABLE 4.504.5. VERIFICATION OF COMPLIANCE WITH THESE SECTIONS MUST BE PROVIDED AT HE TIME OF INSPECTION. ANNUAL SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OR SIMILAR METHODS. DOOR MARKER AWINDOW MARKER 24 A7.1 24 A4.1 24 A5.1 24 A5.1 SECTION MARKER ELEVATION MARKER DETAIL MARKER ∙ 2022 CALIFORNIA RESIDENTIAL CODE ∙ 2022 CALIFORNIA BUILDING CODE ∙ 2022 CALIFORNIA PLUMBING CODE ∙ 2022 CALIFORNIA MECHANICAL CODE ∙ 2022 CALIFORNIA ELECTRICAL CODE ∙ 2022 CALIFORNIA ENERGY CODE. (TITLE 24) ∙ 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 8 A. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL BOXES, TRANSFORMERS, VAULTS, PUMPS, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES - WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. B. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE 170, 158) (INCLUDES COMMERCIAL ADDITIONS AND TI WORK OVER $10,000) SEPARATE PLUMBING PERMIT IS REQUIRED. C. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR TO AN APPROVED SEWAGE DISPOSAL SYSTEM (R306.3) D. KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND WASHING MACHINE OUTLES SHALL BE PROVIDED WITH HOT AND COLD WATER AND CONNECTED TO AN APPROVED WATER SUPPLY (R306.4) E. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWER HEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET AOBVE THE FLOOR (R307.2) F. PROVIDE ULTRA LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. G. PROVIDE 72 INCH HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER-RESISTANT MATERIALS FOR SHOWER ENCLOSURE. (1209.2.3 & 1209.2.4) H. UNIT SKYLIGHTS SHALL BE LABELED BY AN LA CITY APPROVED LABELING AGENCY. SUCH LABEL SHALL STATE THE APPROVED LABELING AGENCY NAME, PRODUCT DESIGNATION AND PERFORMANCE GRADE RATING (RESEARCH REPORT NOT REQUIRED). (R308.6.9) I. WATER HEATER MUST BE STRAPPED TO WALL (SEC. 507.3, UPC) M. SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDED FOR HUMAN OCCUPANCY, UPON THE OWNER'S APPLICATION FOR A PERMIT FOR ALTERATIONS, REPAIRS, OR ADDITIONS, EXCEEDING ONE THOUSAND DOLLARS ($1,000). (R314.6.2) N.A.WHERE A PERMIT IS REQUIRED FOR ALTERATIONS, REPAIRS OR ADDITIONS EXCEEDING ONE THOUSAND DOLLARS ($1,000), EXISTING DWELLINGS OR SLEEPING UNITS THAT HAVE ATTACHED GARAGES OR FUEL BURNING APPLIANCES SHALL BE PROVIDED WITH A CARBON MONOXIDE ALARM IN ACCORDANCE WITH SECTIONS R315.1. CARBON MONOXIDE ALARMS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS OBTAINED. (R315.2) N.B.EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN AVERAGE ILLUMINATION OF 6 FOOT-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30 INCHES ABOVE THE FLOOR LEVEL. (R303.1) O. A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE ARCHITECTURAL DESIGNER DREAM DESIGN BUILDNAME ADDRESS PHONE 1226 W. NINTH ST. UPLAND, CA 91786 310.487.1613 E-MAIL HELLO@DREAMDESIGN.BUILD WEBSITE DREAMDESIGN.BUILD CLIENT JUAN CAMACHO NAME ABBREVIATIONS A/C AIR CONDITIONER A.F.F. ABOVE FINISHED FLOOR A.F.G. ABOVE FINISHED GRADE BOT. BOTTOM B.O.F. BOTTOM OF FOOTING C.C. CENTER TO CENTER CL. CLOSET CLG. CEILING CMU CONCRETE MASONRY UNIT DEMO DEMOLISH D.S. DOWNSPOUT DIA. DIAMETER DIM. DIMENSION DN. DOWN D.P. DAMP PROOFING E EXISTING E.F. EXHAUST FAN EXC. EXCAVATE F.A.U. FORCED AIR UNIT F.D. FLOOR DRAIN FIN. FINISH F.F. FINISH FLOOR GALV. GALVANIZED G.C. GENERAL CONTRACTOR G.F.C.I. GROUND FAULT CIRCUIT INTERUPT G.F.I. GROUND FAULT INTERRUPT G.T. GLAZED TILE GYP. GYPSUM H.V.A.C. HEATING, VENTILATION & AIR CONDITIONING H.W. HOT WATER IN. INCH INSUL. INSULATION INT. INTERIOR JST. JOIST LFT. LINEAR FEET LTG. LIGHTING L.V.L. LAMINATED VENEER LUMBER MAS. MASONRY MTL. METAL MIN. MINIMUM N NEW N.T.S. NOT TO SCALE O.C. ON CENTER O.D. OUTSIDE DIAMETER OPNG. OPENING / ROUGH OPENING P.C.C. PORTLAND CEMENT CONCRETE PL.PLASTER P.L.PROPERTY LINE PLYWD. PLYWOOD PTD. PAINTED R.C. REINFORCED CONCRETE R.D. ROOF DRAIN R.D.L. ROOF DRAIN LEADER R.O. ROUGH OPENING R.O.W. RIGHT OF WAY REINF. REINFORCED SAN. SANITARY S.D. SMOKE DETECTOR SHT. SHEET SHT'G. SHEATHING SQ. FT. SQUARE FEET SQ. IN. SQUARE INCHES STD. STANDARD T&B TOP & BOTTOM T.O. TOP OF U.N.O. UNLESS NOTED OTHERWISE V.B. VAPOR BARRIER W.C. TOILET (WATER CLOSET) WD. WOOD WDW. WINDOW W.I.C. WALK-IN CLOSET WP. WEATHERPROOF TYP. TYPICAL WS. WEATHER-STRIPPING W.S. WATER STOP W/O WITHOUT H.M. HOLLOW MATERIAL / CORE S.C. SOLID CORE SYMBOL LEGEND APPLICABLE CODES SINGLE FAMILY DWELLING:1,374 SQ. FT. COVERED PATIO: LOT NO: 35 # OF STORIES: 1 APN: 412-402-35 MAX. BUILDING HEIGHT: 14'-2" ZONING: R-3 PARKING REQ.: YEAR BUILT: 1960 TRACT #: TR 3679 PROJECT ADDRESS: 1901 W HALL AVE SANTA ANA, CA 92704 DESIGNER: DDB, LLC SCOPE OF WORK: (E) GARAGE WALLS TO BE DRYWALLED (NO NEW INSULATION) (N) EXTERIOR WATER HEATER ENCLOSURE (TO MATCH EXISTING HOME) (E) COVERED PATIO & SHED TO BE REMOVED. UNPERMITED ELECTRICAL AND PLUMBING WORK TO BE REMOVED FROM GARAGE UNPERMITED DRYWALL TO BE REMOVED FROM GARAGE CEILING OCCUPANCY: R-3 / U CONSTRUCTION TYPE: V-B // NON-FIRE SPRINKLERED PROJECT INFO LEGAL DESCRIPTION: PHONE: 310.487.1613 PROPERTY AREA: EXISTING 6,083 SQ. FT. TOTAL (LOT COVERAGE):2,133 SQ. FT. LOT COVERAGE (SFD + PATIO + GARAGE) / PROPERTY AREA 35.06% FIRE HAZARD SEVERITY ZONE: NO 435 SQ. FT. 324 SQ. FT. 2-CAR GARAGE: TOTAL (FLOOR AREA):1,374 SQ. FT. NORTH SITE LOCATION BLDG #102120916 APPROVALS: PLNG - C. Santana HOLD- 1901 W Hall Ave11/19/2024 1226 W. NINTH ST. UPLAND, CA 91786 310.487.1613 HELLO@DREAMDESIGN.BUILD DREAMDESIGN.BUILD OWNER: JUAN CAMACHO ADDRESS: 1901 W HALL AVE SANTA ANA, CA 92704 SCOPE OF WORK: (E) GARAGE WALLS TO BE DRYWALLED (NO NEW INSULATION) (N) EXTERIOR WATER HEATER ENCLOSURE (TO MATCH EXISTING HOME) (E) COVERED PATIO & SHED TO BE REMOVED. UNPERMITED ELECTRICAL AND PLUMBING WORK TO BE REMOVED FROM GARAGE UNPERMITED DRYWALL TO BE REMOVED FROM GARAGE CEILING PLANS PREPARED BY: RESTRICTIVE NOTICE: ALL DESIGNS, IDEAS, DETAILS, PLANS & SPECIFICATIONS INDICATED BY THE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF DDB,LLC. THE PLANS WERE CREATED AND DEVELOPED FOR USE ON AND IN CONJUNCTION WITH THE SPECIFIC PROJECT DESCRIBED HEREIN. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, MODIFIED OR DISTRIBUTED TO OTHERS WITHOUT PRIOR WRITTEN AND SPECIFIC CONSENT FROM DDB, LLC. EXISTING & PROPOSED SITE PLANS A1.0 SCALE: DRAWN: CHECKED: DATE: REVISION: REVISION: EDGAR VIDAL 9/18/24 AS SHOWN E. VIDAL 33'-10"20'-7"7'-2"21'-7"17'-6" 22'-3" 18'-2" 7'-8" 31'-10" 6'-11" 19'-7" 18'-1" 17'-7" 23'-3" 25'-4" 23'-2" 6'-0" 6'-11" 14'-0" W H 107.57 (E) APPROACH (E) CONCRETE DRIVEWAY 100.73 W H A L L A V E 84.19 (E) HARDSCAPE (E) LANDSCAPE TO REMAIN (E) LANDSCAPE TO REMAIN 2-CAR GARAGE 435 SQ. FT. UP (E) SINGLE FAMILY DWELLING 1,374 SQ. FT. 33'-10"20'-7"7'-2"21'-7"17'-6" 22'-3" 18'-2" 7'-8" 31'-10" 6'-11" 19'-7" 18'-1" 17'-7" 23'-3" 25'-4" 23'-2" 6'-0" 6'-11" 14'-0" 0'-6" 9'-0" W H 107.57 (E) APPROACH 100.73 W H A L L A V E 84.19 (E) LANDSCAPE TO REMAIN (E) LANDSCAPE TO REMAIN 2-CAR GARAGE 435 SQ. FT. (E) COVERED PATIO 324 sq ft TO BE DEMO UP (E) SINGLE FAMILY DWELLING 1,374 SQ. FT. (E) SHED 80 sq ft TO BE DEMO PROPOSED SITE PLAN 1/8" = 1'-0" EXISTING SITE PLAN 1/8" = 1'-0" 200 AMP METER A/C UNIT W/ 220V DISCONNECT BOX SYMBOL LEGEND TANKLESS WATER HEATER HEAT PUMP GAS METER DUAL GANG 200 AMP PANEL EXISTING PROJECT IMPROVEMENTS 6' HIGH 8" BLOCK WALL CITY LIGHT POLE WATER LINE PROPERTY LINE LINE LEGEND EXISTING PROJECT IMPROVEMENTS GAS LINE SEWER LINE DRAIN LINE 2% MINIMUM SLOPE FENCE WATER HEATER TO BE ENCLOSED & ENCLOSURE TO MATCH FINISH OF MAIN HOME WATER HEATER WH WH NORTH NORTH HOLD- 1901 W Hall Ave11/19/2024 1226 W. NINTH ST. UPLAND, CA 91786 310.487.1613 HELLO@DREAMDESIGN.BUILD DREAMDESIGN.BUILD OWNER: JUAN CAMACHO ADDRESS: 1901 W HALL AVE SANTA ANA, CA 92704 SCOPE OF WORK: (E) GARAGE WALLS TO BE DRYWALLED (NO NEW INSULATION) (N) EXTERIOR WATER HEATER ENCLOSURE (TO MATCH EXISTING HOME) (E) COVERED PATIO & SHED TO BE REMOVED. UNPERMITED ELECTRICAL AND PLUMBING WORK TO BE REMOVED FROM GARAGE UNPERMITED DRYWALL TO BE REMOVED FROM GARAGE CEILING PLANS PREPARED BY: RESTRICTIVE NOTICE: ALL DESIGNS, IDEAS, DETAILS, PLANS & SPECIFICATIONS INDICATED BY THE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF DDB,LLC. THE PLANS WERE CREATED AND DEVELOPED FOR USE ON AND IN CONJUNCTION WITH THE SPECIFIC PROJECT DESCRIBED HEREIN. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, MODIFIED OR DISTRIBUTED TO OTHERS WITHOUT PRIOR WRITTEN AND SPECIFIC CONSENT FROM DDB, LLC. EXISTING FLOOR PLAN A2.1 SCALE: DRAWN: CHECKED: DATE: REVISION: REVISION: EDGAR VIDAL 9/18/24 AS SHOWN E. VIDAL NE1 A2.3 SW1 A2.3 NW1 A2.3 SE1 A2.3 DN DN F 3'-7" 21'-3"11'-7" 32'-10" 32'-10" 21'-1" 8'-11" 30'-0" 21'-7"7'-4"20'-7" 49'-6" 22'-0" 24'-8" 11'-8" 58'-4" W.H. MASTER BEDROOM BEDROOM II BEDROOM III KITCHEN LIVING BATHROOM BATHROOM CLOSET CLOSET CLOSET CLOSET CLOSET COVERED PATIO DINING 2-CAR GARAGE DN EXISTING GROUND FLOOR PLAN 1/4" = 1'-0" EXISTING WALL TO BE DEMO SYMBOL LEGEND EXISTING RETAINING WALL NORTH HOLD- 1901 W Hall Ave11/19/2024 1226 W. NINTH ST. UPLAND, CA 91786 310.487.1613 HELLO@DREAMDESIGN.BUILD DREAMDESIGN.BUILD OWNER: JUAN CAMACHO ADDRESS: 1901 W HALL AVE SANTA ANA, CA 92704 SCOPE OF WORK: (E) GARAGE WALLS TO BE DRYWALLED (NO NEW INSULATION) (N) EXTERIOR WATER HEATER ENCLOSURE (TO MATCH EXISTING HOME) (E) COVERED PATIO & SHED TO BE REMOVED. UNPERMITED ELECTRICAL AND PLUMBING WORK TO BE REMOVED FROM GARAGE UNPERMITED DRYWALL TO BE REMOVED FROM GARAGE CEILING PLANS PREPARED BY: RESTRICTIVE NOTICE: ALL DESIGNS, IDEAS, DETAILS, PLANS & SPECIFICATIONS INDICATED BY THE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF DDB,LLC. THE PLANS WERE CREATED AND DEVELOPED FOR USE ON AND IN CONJUNCTION WITH THE SPECIFIC PROJECT DESCRIBED HEREIN. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, MODIFIED OR DISTRIBUTED TO OTHERS WITHOUT PRIOR WRITTEN AND SPECIFIC CONSENT FROM DDB, LLC. PROPOSED FLOOR PLAN A3.0 SCALE: DRAWN: CHECKED: DATE: REVISION: REVISION: EDGAR VIDAL 9/18/24 AS SHOWN E. VIDAL NE A4.0 SW A4.0 NW A4.0 SE A4.0 DN DN 33 F 3'-7" 21'-3"11'-7" 32'-10" 32'-10" 21'-1" 8'-11" 30'-0" 21'-7"7'-4"20'-7" 49'-6" 22'-0" 24'-8" 11'-8" 58'-4" 1 W.H. MASTER BEDROOM BEDROOM II BEDROOM III KITCHEN LIVING BATHROOM BATHROOM CLOSET CLOSET CLOSET CLOSET CLOSET DINING 2-CAR GARAGE DN A-A A5.0 A-A A5.0 B-B A5.0 B-B A5.0 (N) 1/2" DRYWALL PROPOSED GROUND FLOOR PLAN 1/4" = 1'-0" 1" MAX THRESHOLD TO LANDING BELOW EXISTING WALL NEW FRAME WALLS W/ STUDS @ 16" O.C. 5/8" DRYWALL @ INTERIOR & 7/8" STUCCO @ EXTERIOR TO BE DEMO SYMBOL LEGEND NEW FRAME WALLS W/ STUDS @ 16" O.C. 5/8" DRYWALL @ INTERIOR & EXTERIOR EXISTING RETAINING WALL TANKED WATER HEATER TO BE ENCLOSED IN A MATCHING ENCLOSURE FINISH TO THE MAIN HOUSE (SEE PROPOSED SOUTHEAST ELEVATION SHEET A4.0) 1 KEYNOTES 1. REMOVAL OF UNPERMITTED PLUMBING INSIDE THE GARAGE 2. REMOVAL OF UNPERMITTED ELECTRICAL WORK INSIDE THE GARAGE NOTES NORTH HOLD- 1901 W Hall Ave11/19/2024