HomeMy WebLinkAbout2000 E 4th St #308 & 309 - PlanBldg #'s 101119778-79 APPROVALS: PLNG - C. Santana BLDG - J. Lo POLICE - B. Martin 2000 E 4th St #308 & 3092/25/2025 EXISTING AND DEMOLITION PLAN A-1.0 1/8" = 1'-0" PROJECT: DATE: DRAWN: SCALE: PROJECT NO: REVIEWED: SHEET NO: SHEET TITLE: DATE DESCRIPTION DELTA DRAWINGS ISSUE 05/22/2024 ISSUE FOR PLAN CHECK OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY SAA INTERIORS ARE AND SHALL REMAIN ITS PROPERTY. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, DISPLAY, SALE, OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF SHLEMMER ALGAZE ASSOCIATES. COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED SUITE 308 DEMISING AND NEW SUITE 309 ADDRESS SUITE 308 AND 309 2000 E. 4TH STREET SANTA ANA, CA 05/22/2024 P.T. P.T. 634519 STAMP AND SIGNATURE: CONSULTANTS: 6083 Bristol Parkway Culver City, CA 90230 515 South Flower St., Suite 1200 Los Angeles, CA 90071 18600 MacArthur Blvd., Suite 100 Irvine, CA 92612 485C US Route 1 South, Suite 105 Iselin, NJ 08830 www.saaia.com T 310.553.3252 T 213.929.1400 T 949.724.8958 San Francisco, CA 94105 T 415.390.6793 T 848.200.1200 New York, NY 10017 T 917.512.6688 575 Market St., Suite 502 711 3rd Ave., 6th Floor S A N F R A N C I S C O , C A • I S E L I N , N J • N E W Y O R K , N Y C U L V E R C I T Y , C A • I R V I N E , C A • L O S A N G E L E S , C A IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE AT THE TIME OF AND RELATING TO COVID-19 CONTAIN RECOMMENDATIONS FROM THE CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH ORGANIZATION (WHO), SUCH RECOMMENDATIONS ARE ONLY VALID AS OF THE DATE THE DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY THEIR RECOMMENDATIONS AT ANY TIME PER THEIR DISCRETION. IN USING RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT ACKNOWLEDGES THAT IT WAS BASED ON THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF THESE DRAWINGS AND MATERIALS BY OTHERS. SAA'S SERVICES ARE INTENDED TO ONLY BE OF ASSISTANCE AND GUIDANCE FOR OUR CLIENT'S STRATEGIES AND DO NOT CONSTITUTE AS REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR COMPLETENESS OF THE DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO INFORMATION DOES NOT CONSTITUTE ENDORSEMENT BY THE U.S. GOVERNMENT, DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. 06/06/2024 PRE-SCREENING CORRECTIONS A DEMOLITION LEGEND DEMOLITION KEYNOTES REMOVE EXISTING DOOR, FRAME AND HARDWARE AT NOTED DOORS. VERIFY WITH LANDLORD TO KEEP EXISTING DOORS AT LANDLORD'S ATTIC STOCK. 1.1 EXISTING WALL TO REMAIN. EXISTING DOOR TO REMAIN. CLEAN, REPAIR AND REPAINT DOOR PER FINISH PLANS AND DOOR SCHEDULE. EXISTING PARTITION TO BE DEMOLISHED AND REMOVED FROM SITE. AREA NOT IN CONTRACT (N.I.C.) SUITE 300 SUITE 350 NO CHANGE STAIR 1 ELEC. ROOM STAIR 2 EXISTING 1-HR RATED PARTITION SUITE 310 SUITE 320 SUITE 304 SUITE 306 SUITE 308 NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE 1.1 1.1 SCALEEXISTING AND DEMOLITION PLAN 1/8" = 1'-0"1 N TYPICAL MOUNTING HEIGHT ELEVATION DOOR HANDLE WALL MOUNTED F.L.S. STROBE DEVICE. CASEWORK MOUNTING HEIGHTS CERTAIN ELEVATION DIMENSIONS ARE ASSOCIATED WITH CODE REQUIRED MAXIMUM OR MINIMUM MOUNTING HEIGHTS. SUCH DIMENSIONS SHOULD BE HELD DESPITE VARIATIONS IN THE SLAB. CODE DIMENSIONS ARE IN PARENTHESIS WITH AN ASTERISK NEXT TO THE CRITICAL DIMENSION. E.G.: (* +15" MIN.) CONTROL ELEVATIONS ARE COMPRISED OF: FINISH CEILING LEVEL (FCL) FINISH FLOOR LEVEL (FFL) TOP OF SLAB (TOS) ALL DIMENSIONS GIVEN ARE FROM FFL DATUM. FINISH FLOOR MATERIAL IS ASSUMED TO BE 3/8" THICK GLUE DOWN CARPET. FLOOR FINISH AND THICKNESS WILL VARY FROM LOCATION TO LOCATION. REFER TO PLANS AND DETAILS FOR SPECIFIC FLOORING INFORMATION. NO ALLOWANCE HAS BEEN MADE FOR ANY DEPRESSIONS OR ELEVATIONS IN THE SLAB. ELEVATION HEIGHTS SHOULD TAKE INTO ACCOUNT ANY VARIATIONS IN THE FLOOR SLAB. ELECTRICAL MOUNTING HEIGHTS CONTROL ELEVATIONS KEY CARD READER OR THERMOSTAT CLG. HT. +60" BOT. OF CASEWORK OVHDS. (* +2'-10" MAX.) COUNTER +2'-10" +2'-6" CASEWORK DESK J BOX AT DESK +21" TYP. J-BOX OUTLET +18"* COAT CLOSET SHELF +48" +34"-44" DOOR HANDLE FIN. FLR. 0'- 0" FIRE EXTINGUISHER CABINET, SEE A2.0 FOR TYPE. PAINT CABINET TO MATCH ADJACENT WALL. PROVIDE NEW FIRE EXTINGUISHER SUSPENDED IN CABINET CL CL ADJUST CENTERLINE DIMENSION TO 12" AS REQUIRED TO ACCOMMODATE MULTIPLE GANGED DEVICES WALL SWITCH, DIMMER OR WALL MOUNTED MOTION SENSOR, WALL PHONES AND "J" BOXES AT COUNTERS. MULTIPLE SWITCHES TO BE GANGED INTO ONE COVER PLATE. ELECT. WALL OUTLET. MULTIPLE OUTLETS TO BE GANGED INTO ONE COVER PLATE. CL DIMENSION SHOWN FOR REFERENCE ONLY. FINAL LOCATION TO BE APPROVED BY SAA AND/OR TENANT. NOTES: 1.ALL VERTICAL DIMENSIONS ARE SHOWN FROM FINISH FLOOR TO LOCATION SHOWN. 2.THE THERMOSTAT AND CARD READERS SHALL BE LOCATED SO THAT THE TOP OF THE OUTLET BOX IS NO MORE THAN 48" NOR LESS THAN 15" TO THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISHED FLOOR (2022 CBC 11B-308.2.1). 1' - 6 " 44 " A . F . F . M A X T O T O P O F B O X +8 0 " - 9 6 " A . F . F . 6" MI N . C L R . 6" 12" A 2000 E 4th St #308 & 3092/25/2025 ELEVATION VIEW B - C - EXISTING METAL STUD WALL, GC TO V.I.F. NEW METAL STUD WALL INFILL PER PLAN. PAINT AND REFINISH AS REQUIRED TO MATCH EXISTING. PE R P L A N ( V . I . F . ) PER PLAN (V.I.F.) NOT TO SCALEA (N) 20 GA NON-SLOTTED METAL TOP TRACK WITH #10 S.M.S. EACH FLANGE, EACH STUD (2) #10 S.M.S @ 24" O.C. MIN. TO EXISTING TRACK. EX I S T I N G NE W I N F I L L AL I G N EXISTING METAL STUD WALL, GC TO V.I.F. (1) LAYER OF 5/8" TYPE 'X' GYP. BRD. ON BOTH SIDES, TYP. PROVIDE TAPE AND MUD AT ALL JOINTS AND SEAMS, SMOOTH AS REQUIRED (TYPICAL). STUD WALLS TO MATCH EXISTING EXISTING CONCRETE SLAB. NO PUNCH-OUT SHALL OCCUR WITHIN 12" CLEAR FROM END OF STUD. WALL BASE TO MATCH EXISTING, GC TO V.I.F. METAL BOTTOM TRACK, (GAUGE TO MATCH STUD, 20 GA. MIN.) ATTACHED TO SLAB W/ .145" DIAMETER POWER - DRIVEN FASTENER MIN. 1-1/4" EMBEDMENT AT 24" O.C. (ICC-ESR# 1663). #10 S.M.S. EA. FLANGE, EA. STUD. CONTINUOUS ACOUSTICAL SEALANT, TYP. 12 " M I N METAL STUDS AT 16" O.C. MAX, GC TO MATCH (E) STUD SIZE, V.I.F. WALL SECTION DETAILB3" = 1'-0" ST U D W A L L S TO M A T C H EX I S T I N G (N) METAL STUD TO MATCH EXISTING, GC TO V.I.F. ATTACH TO EXISTING STUD W/ (2) #10 SMS @ 24" O.C. VERTICALLY. EXISTINGNEW INFILL PROVIDE TAPE AND MUD AT ALL JOINTS AND SEAMS, SMOOTH AS REQUIRED (TYPICAL). ALIGN EXISTING METAL STUD WALL, GC TO V.I.F. PORTION OF NEW WALL INFILL PER PLAN. (1) LAYER OF 5/8" TYPE 'X' GYP. BRD. ON BOTH SIDES, TYP. WALL VIEW DETAILC3" = 1'-0" 43'-6" TOTAL EXIT ACCESS TRAVEL DISTANCE = 117'-0" (<200'-0") COMMON PATH OF EGRESS TRAVEL = 73'-6" (<75'-0") COMMON PATH OF EGRESS TRAVEL = 40'-0" (<75'-0") A A1 TO STAIR 2 A2 B B1 TO STAIR 1 B2 51 ' - 0 " TO T A L E X I T A C C E S S T R A V E L D I S T A N C E = 9 1 ' - 0 " ( < 2 0 0 ' - 0 " ) PROPOSED PLAN AND CONSTRUCTION DETAILS A-2.0 PARTITION LEGEND 1/8" = 1'-0" PROJECT: DATE: DRAWN: SCALE: PROJECT NO: REVIEWED: SHEET NO: SHEET TITLE: DATE DESCRIPTION DELTA DRAWINGS ISSUE 05/22/2024 ISSUE FOR PLAN CHECK OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY SAA INTERIORS ARE AND SHALL REMAIN ITS PROPERTY. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, DISPLAY, SALE, OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF SHLEMMER ALGAZE ASSOCIATES. COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED SUITE 308 DEMISING AND NEW SUITE 309 ADDRESS SUITE 308 AND 309 2000 E. 4TH STREET SANTA ANA, CA 05/22/2024 P.T. P.T. 634519 STAMP AND SIGNATURE: CONSULTANTS: 6083 Bristol Parkway Culver City, CA 90230 515 South Flower St., Suite 1200 Los Angeles, CA 90071 18600 MacArthur Blvd., Suite 100 Irvine, CA 92612 485C US Route 1 South, Suite 105 Iselin, NJ 08830 www.saaia.com T 310.553.3252 T 213.929.1400 T 949.724.8958 San Francisco, CA 94105 T 415.390.6793 T 848.200.1200 New York, NY 10017 T 917.512.6688 575 Market St., Suite 502 711 3rd Ave., 6th Floor S A N F R A N C I S C O , C A • I S E L I N , N J • N E W Y O R K , N Y C U L V E R C I T Y , C A • I R V I N E , C A • L O S A N G E L E S , C A IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE AT THE TIME OF AND RELATING TO COVID-19 CONTAIN RECOMMENDATIONS FROM THE CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH ORGANIZATION (WHO), SUCH RECOMMENDATIONS ARE ONLY VALID AS OF THE DATE THE DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY THEIR RECOMMENDATIONS AT ANY TIME PER THEIR DISCRETION. IN USING RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT ACKNOWLEDGES THAT IT WAS BASED ON THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF THESE DRAWINGS AND MATERIALS BY OTHERS. SAA'S SERVICES ARE INTENDED TO ONLY BE OF ASSISTANCE AND GUIDANCE FOR OUR CLIENT'S STRATEGIES AND DO NOT CONSTITUTE AS REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR COMPLETENESS OF THE DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO INFORMATION DOES NOT CONSTITUTE ENDORSEMENT BY THE U.S. GOVERNMENT, DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. 06/06/2024 PRE-SCREENING CORRECTIONS A AREA NOT IN CONTRACT (N.I.C.). EXISTING CONSTRUCTION TO REMAIN. EXISTING DOOR, DOOR FRAME AND DOOR HARDWARE IS TO REMAIN AT LOCATION SHOWN. COMMON PATH OF EGRESS < 75 FEET (1006.2.1 CBC) MAXIMUM PATH OF TRAVEL <200 FEET (1017.2 CBC) OCCUPANCY LOAD AND EXIT CALCULATION EXISTING 1-HR RATED PARTITION SUITE 300 SUITE 350 NO CHANGE STAIR 1 ELEC. ROOM STAIR 2 SUITE 310 SUITE 320 SUITE 304 SUITE 306 SUITE 308 (N)SUITE 309 NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE AREA = 1,412 SQ. FT. OCCUPANCY = B (OFFICE) OCC. LOAD = 1,412 / 150 = 10 OCC. EXIT REQ'D = 1 EXIT PROVIDED = 1 SUITE 308 AREA = 424 SQ. FT. OCCUPANCY = B (OFFICE) OCC. LOAD = 424 / 150 = 3 OCC. EXIT REQ'D = 1 EXIT PROVIDED = 1 SUITE 309 CONSTRUCTION KEYNOTES INFILL EXISTING WALL WHERE DOORS HAVE BEEN REMOVED. MATCH EXISTING STUD WIDTH, TAPE, SAND, SMOOTH AND PREP FOR NEW FINISHES. PROVIDE PAINT AND NEW BASE TO MATCH EXISTING. 2.1 2.1 SCALEDOOR IN-FILL DETAILS AS SPECIFY 2 2.1 SCALEPROPOSED PLAN 1/8" = 1'-0"1 A N A A 2000 E 4th St #308 & 3092/25/2025 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM PT PT 2000 E 4th St #308 & 3092/25/2025