HomeMy WebLinkAbout1900 E 4th St - PlanSYMBOLS DESCRIPTION 01/A-2.00 01 A-4.00 N NORTH ARROW ENLARGE FLOOR PLAN REFERENCE 01 A-4.00 DETAIL SECTION INTERIOR ELEVATION 11 5/8" 5" DIMENSIONS 1 REVISION NUMBER & AFFECTED AREA WINDOW TYPE22 ROOM NAME, ABBREVIATION, & NUMBER IDENTIFICATION 1001A DOOR/OPENING IDENTIFICATION SEE SCHEDULE ON A6-01 A3 1 PARTITION DESIGNATION HOURLY "FIRE RESISTIVE RATING" IF APPLICABLE PARTITION TYPE ROOM NAME ROOM ABBREV 1001 A D 1 - 1 1 LEVEL 1 DESIGNATOR LEVEL 2 DESIGNATOR (OPTIONAL) SHEET TYPE DESIGNATOR FLOOR LEVEL (FOR PLANS ONLY) SHEET SEQUENCE NUMBER LEVEL 1 DESIGNATORS G GENERAL H HAZARDOUS MATERIALS V SURVEY / MAPPING B GEOTECHNICAL C CIVIL L LANDSCAPE S STRUCTURAL A ARCHITECTURAL I INTERIORS Q EQUIPMENT F FIRE PROTECTION P PLUMBING M MECHANICAL E ELECTRICAL T SECURITY R RESOURCES X OTHER DISCIPLINES Z CONTRACTOR SHOP DRAWINGS O OPERATIONS LEVEL 2 DESIGNATORS (OPTIONAL) S SITE D DEMOLITION E ELEMENT P POWER L LIGHTING SHEET TYPE DESIGNATORS 0 GENERAL (OPTIONAL USE AS DEMO) 1 PLANS 2 ELEVATIONS 3 SECTIONS 4 ENLARGED PLANS 5 DETAILS 6 SCHEDULES 7 USER DEFINED 8 USER DEFINED 9 3D VIEWS OWNER'S REPRESENTATIVE: KAISER FOUNDATION HEALTH PLAN INC. 1707 BARCELONA CIRCLE PLACENTIA, CA 92870 CONTACT: JEFFREY S. MONTERO SENIOR PROJECT MANAGER E-MAIL JEFF.S.MONTERO@KP.ORG ARCHITECT: HUITT-ZOLLARS 555 W 5TH ST., SUITE 2950 LOS ANGELES, CA 90013 CONTACT: STEVE WHITE, AIA, LEED AP PROJECT ARCHITECT E-MAIL SWHITE@HUITT-ZOLLARS.COM 310.447.7466 ELECTRICAL ENGINEER: DPB ENGINEERS, INC. 150 EL CAMINO REAL, SUITE 106 TUSTIN, CA 92780 CONTACT: MARCO REBOLLEDO ELECTRICAL ENGINEER E-MAIL: MARCO.REBOLLEDO@SALASOBRIEN.COM MECHANICAL ENGINEER: ATC INC. 5755 OBERLIN DR., SUITE 112 SAN DIEGO, CA 92121 CONTACT: JUSTIN NGUYEN MECHANICAL ENGINEER E-MAIL JNGUYEN@ATCONSULTANTS.NET PLUMBING ENGINEER: ATC INC. 5755 OBERLIN DR., SUITE 112 SAN DIEGO, CA 92121 CONTACT: JUSTIN NGUYEN MECHANICAL ENGINEER E-MAIL JNGUYEN@ATCONSULTANTS.NET STRUCTURAL ENGINEER: WPM 633 W. 5TH ST. SUITE 7200 LOS ANGELES, CA 90071 CONTACT: DANIEL TRAUB STRUCTURAL ENGINEER E-MAIL DTRAUB@WALTERPMOORE.COM GENERAL NOTES 1. U.O.N., SPECIFIC NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. SPECIFIC NOTES ON DETAILS APPLY TO SIMILAR CONDITIONS. 2. THE STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS AS WELL AS THE DRAWINGS OF OTHER CONSULTANTS ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF THE WORK SHOWN ON THE DRAWINGS OF CONSULTANTS. THE CONTRACTOR SHALL BRING ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL DRAWINGS AND THE DRAWINGS OF THE CONSULTING ENGINEERS TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATIONS. ANY WORK INSTALLED IN CONFLICT THE ARCHITECTURAL DRAWINGS AND NOT BROUGHT TO THE ARCHITECTS ATTENTION SHALL BE CORRECTED BY THE CONTRACTOR AT THE CONTRACTORS' EXPENSE AND AT NO EXPENSE TO THE OWNER OR THE ARCHITECT. 3. REFERENCE TO ANY DETAIL OR DRAWING IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH A DRAWING OR DETAIL. 4. U.O.N., OR REFERENCED ON ARCHITECTURAL DRAWINGS, ALL DETAILS ARE TYPICAL. 5. THE CONTRACT DOCUMENTS INDICATED THE CONCEPT AND POTENTIAL METHOD OF EXECUTING THE WORK. FIELD MODIFICATIONS MAY BE REQUIRED AND SHALL BE PART OF THE SCOPE OF WORK. 6. THE INTENTION OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, EQUIPMENT AND TRANSPORTATION NECESSARY FOR THE COMPLETE AND PROPER EXECUTION OF THE WORK. 7. NO MODIFICATIONS FROM THE DOCUMENTS SHALL BE CONDUCTED PRIOR TO THE APPROVAL OF THE OWNER AND ARCHITECT. 8. DISCREPANCIES IN DRAWINGS OR SPECIFICATIONS, OR BETWEEN DRAWINGS, SPECIFICATIONS AND OR SITE CONDITIONS SHALL BE REVIEWED WITH THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK. 9. REFER TO STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR EQUIPMENT ANCHORAGE, HVAC, PLUMBING, LIGHTING, COMMUNICATION, DATA AND POWER REQUIREMENTS. 10. THE DESIGN, ADEQUACY AND SAFETY OF ERECTION, BRACING, SHORING, TEMPORARY SUPPORTS, ETC., IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE AND PROVIDE NECESSARY BRACING PRIOR TO THE APPLICATION OF ALL SHEAR WALLS, ROOF, AND FLOOR DIAPHRAGMS, AND FINISH MATERIALS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INITIATING, MANUFACTURING AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. 11. THE ARCHITECT AND ARCHITECT'S CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT LIMITED TO ASBESTOS, ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES. 12. IF THE CONTRACTOR ASCERTAINS AT ANY TIME THAT REQUIREMENTS OF THE CONTRACT DOCUMENTS CONFLICT WITH, OR ARE IN VIOLATION OF APPLICABLE LAWS, CODES, REGULATIONS AND ORDINANCES, THE CONTRACTOR SHALL NOT PROCEED WITH WORK IN QUESTION, EXCEPT AT THE CONTRACTOR'S OWN RISK, UNTIL THE ARCHITECT HAS BEEN NOTIFIED IN WRITING AND WRITTEN DETERMINATION IS MADE BY THE ARCHITECT. WHERE COMPLETED OR PARTIALLY COMPLETED WORK IS DISCOVERED TO BE IN VIOLATION WITH APPLICABLE LAWS, CODES, REGULATIONS AND ORDINANCES, CONTRACTOR SHALL BE REQUIRED TO REMOVE THAT WORK FROM THE PROJECT AND REPLACE SUCH WORK WITH ALL NEW COMPLYING WORK AT NO ADDITIONAL COST TO THE OWNER. DIMENSIONING NOTES 1. THE DRAWINGS REFLECT GENERAL ARRANGEMENT, DESIGN AND EXTENT OF WORK, AND ARE NOT TO BE SCALED FOR MEASUREMENTS. THE DRAWINGS ARE PARTLY DIAGRAMMATIC AND ARE NOT INTENDED TO BE AN EXACT REPRESENTATION OF FIELD CONDITIONS OR TO SERVE AS THE CONTRACTOR'S SHOP DRAWINGS. 2. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. DIMENSIONS SHALL GOVERN AND LARGE SCALE DETAILS SHALL GOVERN OVER SMALLER SCALE DRAWINGS. 3. "EXISTING", "(+/-)", "SIZE TO FIT", F.V. AND SIMILAR PHRASES REQUIRE THE CONTRACTOR TO VERIFY AND COORDINATE DIMENSIONS AND CONDITIONS INDICATED IN THE DRAWINGS WITH THE ACTUAL FIELD CONDITIONS. DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT FOR DIRECTION ON HOW TO PROCEED. 4. U.O.N., DIMENSIONS ARE SHOWN TO CENTERLINE OF COLUMNS, TO FACE OF CONCRETE, OR TO FACE OF FINISH OF EXTERIOR AND INTERIOR PARTITION. ALL CEILING HEIGHTS INDICATED ARE FROM FINISH OF FLOOR TO FINISH OF CEILING. 5. DOORS NOT DIMENSIONED AND SHOWN JAMB TIGHT SHALL BE SET 4" FROM PERPENDICULAR WALL TO OUTER EDGE OF DOOR JAMB. 6. U.O.N., RECEPTACLES APPEARING NEXT TO EACH OTHER ON THE PLAN BUT NOT DIMENSIONED SHALL BE EIGHT (8") APART AS MEASURED FROM CENTERLINE TO CENTERLINE. 7. UNLESS OTHERWISE NOTED, RECEPTACLES SHALL BE FIFTEEN (15") INCHES IN HEIGHT ABOVE THE FINISHED FLOOR (AS MEASURED FROM THE RECEPTACLE CENTERLINE TO THE FLOOR DATUM) 8. U.O.N., ADJACENT COVERPLATES WITH DIFFERING SIZES SHALL BE CONFIGURED SO THAT THE TOPS ALIGN AS FOLLOWS: 9. WHEN ADJACENT COVERPLATES ARE THE SAME SIZE, THE CONFIGURATIONS SHALL BE AS FOLLOWS: 10. U.O.N. CEILING FIXTURES AND EQUIPMENT ARE TO BE CENTERED ON CEILING TILES WHEN IN LAY-IN CEILINGS. 11. U.O.N. LIGHT FIXTURES ON HARD SURFACE CEILINGS SHALL BE CENTER IN THE ROOM. 12. U.O.N. SCONCE LIGHTING AT PLUMBING FIXTURES SHALL BE CENTER ON THE FIXTURE. 13. ALL UNDERCABINET TASK LIGHTING SHALL BE INSTALLED AS CLOSE AS POSSIBLE TO THE BACK WALL AND CENTERED BELOW THE CABINETS. 14. WALLS NOT DIMENSIONED SHALL ALIGN WITH EXISTING WALLS OR BE ABUTTED OR APPLIED TO EXISTING WALLS PER DRAWINGS. CONTRACTOR'S RESPONSIBILITY 1. CONTRACTOR SHALL CONTACT THE OWNER 48 HOURS IN ADVANCE OF ANY RESTRICTION OF OWNER ACCESS OR UTILITY OUTAGES. AUTHORIZATION FROM OWNER TO BE RECEIVED IN WRITING. 2. IN THE EVENT THE UTILITY SERVICE IS INTERRUPTED WITHOUT THE REQUIRED 48 HOURS NOTICE, THEN THE CONTRACTOR SHALL BE FINANCIALLY LIABLE FOR ALL DAMAGES SUFFERED BY THE OWNER DUE TO THE UNAUTHORIZED INTERRUPTION. RECONNECTION SHALL BE MADE IMMEDIATELY. 3. CONTRACTOR SHALL VISIT THE SITE TO AS TO FAMILIARIZE WITH EXISTING CONDITIONS AND SATISFY THEMSELVES TO THE NATURE AND SCOPE OF THE WORK. SUBMISSIONS OF PROPOSALS SHALL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN WITH SUCH EXAMINATION WILL NOT BE RECOGNIZED. 4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BEGINNING WORK. AT ANY TIME SHOULD CONDITIONS ARISE WHEREIN THE INTENT OF THE DRAWINGS IS IN DOUBT OR WHERE THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND FIELD CONDITIONS THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IN WRITING FOR CLARIFICATION. 5. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. SAFETY OF ALL PARTIES PRESENT ON THE JOB SITE IS SOLELY THE CONTRACTOR'S RESPONSIBILITY. 6. THE CONTRACTOR SHALL HAVE FULL RESPONSIBILITY AND CHARGE OF AND SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTOR OR ANY OTHER PERSONS PERFORMING ANY WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. PROVIDE CONTINUOUS INSPECTION IN ACCORDANCE WITH THE BUILDING CODE FOR REINFORCED CONCRETE. PLACEMENT OF REINFORCING STEEL, STRUCTURAL STEEL, WELDING, STRUCTURAL MASONRY, FIELD WELDING AND HIGH STRENGTH BOLTS. 8. CONTRACTOR TO SCHEDULE CONSTRUCTION ACTIVITIES TO HAVE THE LEAST IMPACT ON EXISTING FUNCTIONS, CONTAIN ACTIVITIES SUCH AS THE USE OF JACKHAMMERS SHALL BE SCHEDULED AT SPECIAL TIMES. CONTACT THE DESIGNATED NOISE DISTURBANCE COORDINATOR FOR SCHEDULING OF ALL ACTIVITIES. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF EXISTING HVAC FILTERS WITHIN AREAOF WORK. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF AND WHERE REQUIRED BY THE FIRE MARSHAL, THE OPERATIONAL MAINTENANCE OF FIRE LIFE SAFETY DEVICES WITHIN THE AREA OF WORK. EXISTING CONDITIONS 1. U.N.O. SURFACES ADJOINING AREAS OF DEMOLITIONS AND/OR NEW WORK SHALL BE PATCHED AND REFINISHED AS REQUIRED TO MATCH ADJACENT SURFACES IN ALL ASPECTS, INCLUDING FINISH MATERIAL, COLOR, TEXTURE, FIRE RATING AND SUBSTRATE. 2. PATCH SURFACES WHERE AFFECTED BY INSTALLATION OF NEW MECHANICAL, ELECTRICAL AND STRUCTURAL ITEMS. MATCH EXISTING ADJACENT SURFACES AND FINISHES EXCEPT WHERE OTHERWISE NOTED OR INDICATED. 3. WHERE NEW WALL OR CEILING CONTINUES EXISTING WALL OR CEILING, ALIGN VISIBLE NEW SURFACE WITH EXISTING. ADJUST AND STAGGER STUDS IF REQUIRED TO ALIGN STUDS IF REQUIRED TO ALIGN FACE OF WALLS. 4. THE CONTRACTOR SHALL SUPERVISE ALL CUTTING, PATCHING, REPAIRING, RESTORING, AND ANY NECESSARY ACTION TO COMPLETE THE WORK. THE CONTRACTOR SHALL RESTORE AND MATCH ANY DAMAGED WORK TO THE ORIGINAL CONDITION TO THE ARCHITECT'S SATISFACTION. 5. EXISTING CONDITIONS AND OPERATIONS SHALL BE DOCUMENTED PRIOR TO INITIATION OF RENOVATION AND/ OR NEW CONSTRUCTION PROJECTS. THIS SHALL INCLUDE DOCUMENTATION OF EXISTING MECHANICAL/ELECTRICAL/ STRUCTURAL CAPACITIES AND QUANTITIES. DOCUMENTATION OF EXISTING CONDITIONS SHOULD INCLUDE THE FOLLOWING: A. FIRE SUPPRESSION, DETECTION, AND ALARM SYSTEMS B. VARIOUS COMMUNICATIONS SYSTEMS (INCLUDING TELEPHONE, NURSE CALL, OVERHEAD PAGING, TELEMETRY, DICTATION, ELECTRONIC IMAGING) VARIOUS PLUMBING SYSTEMS (INCLUDING DOMESTIC WATER, TREATED WATER, WASTEWATER, PNEUMATIC TUBE, PNEUMATIC CONTROLS, MEDICAL GASES/ VACUUM) C. EXISTING AIRFLOW OF AFFECTED AREAS D. MAIN ELECTRICAL SERVICE AND ELECTRICAL SERVICE AFFECTED BY CONSTRUCTION (INCLUDING RATING AND ACTUAL LOAD/PEAK AND FEEDER SIZES AS APPLICABLE AND POWER FACTOR) E. EMERGENCY POWER SYSTEM (INCLUDING RATING AND ACTUAL LOAD/PEAK AND FEEDER SIZES, AS APPLICALE, FOR LIFE SAFETY, EMERGENCY/CRITICAL, AND EQUIPMENT BRANCHES) DEMOLITION 1. CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES PRIOR TO COMMENCING CONSTRUCTION AND SHALL TAKE STEPS TO PROTECT SUBJECT UTILITIES, PERSONNEL AND PROPERTY AGAINST DAMAGE OR INJURY. 2. CONTRACTOR SHALL VERIFY LOCATION OF ALL REINFORCING STEEL AND CONDUIT IN EXISTING CONCRETE SLABS AND AVOID SAME. CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR REVIEW BY THE ARCHITECT AND/OR SEOR PRIOR TO PROCEEDING WITH CORE OR SAW-CUTTING. 3. ALL REMOVED FIXTURES, EQUIPMENT, ACCESSORIES AND DOORS SHALL BE SALVAGED TO THE OWNER. ITEMS NOT WANTED BY OWNER SHALL BE DISCARDED OFF-SITE BY THE CONTRACTOR. 4. TEMPORARY STORAGE OF EQUIPMENT SHALL BE PROTECTED FROM VANDALISM. STORE IN A LOCATION THAT IS ACCEPTABLE TO THE OWNER. 5. PROTECT ALL ADJACENT AREAS FROM DUST, FUMES, SMOKE, WATER, WEATHER AND NOISE. 6. PROTECT ALL ADJACENT BUILDING COMPONENTS - FINISHES AND EQUIPMENT. SHOULD DAMAGE OCCUR, REPAINT, PATCH OR REPLACE AT NO ADDITIONAL COST TO THE OWNER. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTINUOUS CLEAN UP OF THE SITE OF ALL DEBRIS WHETHER CREATED BY THE CONTRACTOR'S WORK OR THE FAILURE OF THE CONTRACTOR'S SUB-CONTRACTORS TO CLEAN UP AFTER THEIR WORK. 8. ALL ABANDONED PLUMBING LINES, ELECTRICAL CONDUIT OR BOXES, A/C DUCTS OR DIFFUSERS AND TELEPHONE CABLES WILL BE REMOVED BACK TO CLOSEST FEEDER POINT. 9. DO NOT CUT, DRILL, NOTCH, CORE, ALTER, OR DAMAGE STRUCTURAL ELEMENTS OR FRAMING UNLESS SPECIFICALLY DETAILED ON APPROVED PLANS OR ACCEPTED BY THE SEOR/AOR. FIRE AND LIFE SAFETY MEASURES 1. REQUIRED MEANS OF EGRESS SHALL BE MAINTAINED DURING CONSTRUCTION AND DEMOLITION AT ALL TIMES. 2. TEMPORARY EXITING SHALL BE APPROVED BY THE LOCAL FIRE AUTHORITY. (CFC - 2019, SECTION 3311.2) 3. PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY THE LOCAL FIRE AUTHORITY. 4. CONTRACTOR SHALL PROVIDE PROPER FIRE STOPPING AT EXISTING OR NEW FLOOR AND WALL PENETRATIONS FOR MECHANICAL, PLUMBING, ELECTRICAL AND FIRE SPRINKLER LINES AS REQUIRED PER THE APPROPRIATE UL DESIGN LISTING NUMBER. 5. FIRE PROTECTION SYSTEM SHALL BE MAINTAINED OPERATIONAL AT ALL TIMES DURING ALTERATION. 6. SMOKE DETECTORS SHALL BE COVERED OR REMOVE DURING ALTERATION WHEN REQUIRED BY THE LOCAL FIRE AUTHORITY, COVERINGS PLACED ON OR OVER FIRE PROTECTION DEVICES TO PROTECT THEM FROM DAMAGE DURING CONSTRUCTION PROCESSES SHALL BE IMMEDIATELY REMOVED UPON THE COMPLETION OF THE CONSTRUCTION PROCESSES IN THE ROOM OR AREA IN WHICH THE DEVICES ARE INSTALLED. (CFC -2019, SECTION 3308.7) 7. FIRE RESISTIVE RATED CONSTRUCTION SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION. (CFC - 2019, SECTION 703.1) 8. CUTTING AND WELDING OPERATION SHALL BE IN ACCORDANCE WITH CHAPTER 35 OF THE FIRE CODE. (CFC - 2019, SECTION 3304.6) NONCONFORMING CONDITIONS IN THE EVENT THAT AN EXISTING NONCONFORMING CONDITION IS DISCOVERED DURING THE COURSE OF CONSTRUCTION, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND ARCHITECT. TEMPORARY CONSTRUCTION 1. CONTRACTOR SHALL ARRANGE FOR, IN ADVANCE WITH THE OWNER, CONSTRUCTION STORAGE AND STAGING AREAS NECESSARY TO COMPLETE THE WORK. ALL STORAGE AND STAGING AREAS SHALL BE RETURNED TO THE OWNER IN LIKE ORIGINAL CONDITION. 2. THE CONTRACTOR SHALL PROVIDE ADEQUATE MEANS TO PROTECT FINISHED PARTS OF THE MATERIALS AND EQUIPMENT AGAINST DAMAGE FROM ANY CAUSE DURING THE PROGRESS OF THE WORK AND UNTIL ACCEPTANCE BY THE OWNER. 3. CONTRACTOR SHALL MAKE EVERY EFFORT TO MAINTAIN A CLEAN WORK PLACE. DUST PALLIATION AND PREVENTION OF DUST CONTAMINATION OF NON-WORK SPACES WILL BE THE RESPONSIBILITY OF THE CONTRACTOR ON AN ON GOING, DAILY BASIS. THE CONTRACTOR SHALL DEVELOP A SCHEDULE OF CONSTRUCTION WHICH INCLUDES THE NECESSARY ACTIONS TO MAINTAIN THE OPERATION OF THE TENANTS DURING THE CONSTRUCTION PROCESS. 4. CONTRACTOR SHALL MAKE NECESSARY CONNECTIONS TO EXISTING UTILITIES FOR TEMPORARY POWER AND WATER SUPPLIES, AND SHALL COORDINATE SUCH USE WITH THE OWNER PRIOR TO CONNECTION. 15 " M I N . 15 " M I N . 8" ALIGN ALIGN COVER PLATE FLOOR DATUM ALIGN ALIGN FLOOR DATUM COVER PLATE ALIGN FACILITY NAME:SANTA ANA MEDICAL OFFICES FACILITY ADDRESS:1900 E. 4TH STREET SANTA ANA, CA 90025 PROJECT NAME:RAD SAN 1ST FLOOR GEN RAD REPLACEMENT CONSTRUCTION INFORMATION CONSTRUCTION TYPE:TYPE III-B MAIN OCCUPANCY:B, OFFICES YEAR OF CONSTRUCTION: 1991 FIRE EXTINGUISING SYSTEM: AUTOMATIC SPRINKLERS (NFPA 13), THROUGHOUT NUMBER OF STORIES: 3 AREA LIMITATIONS: 57,000 REMODEL INFORMATION REMODEL FLOOR: 1ST FLR REMODEL USE/OCCUPANCY: B (OFFICES) TOTAL REMODEL AREA: 1045 SF PROJECT SCOPE: THIS PROJECT INVOLVES THE RELOCATION OF AN EXISTING IMAGING RADIOLOGY ROOM INTO AN EXISTING CONTROL ROOM. THE EXISTING DRESSING ROOMS WILL BE DEMOLISHED AND REBUILT TO ACCOMODATE THE NEW LOCATION OF THE IMAGING RADIOLOGY ROOM. THE EXISTING LOCATION OF THE IMAGING RADIOLOGY ROOM WILL BE CONVERTED INTO A SHELL SPACE. THIS FACILITY IS NOT A CLINIC OR OUTPATIENT FACILITY LICENSED PERSUANT TO HEALTH AND SAFETY CODE SECTION 1200 OR 1250 AND DOES NOT REQUIRE TO BE OSHPD 3 COMPLIANT. INFECTION CONTROL RISK ASSESSMENT (ICRA) THE INFECTION CONTROL RISK ASSESSMENT IS A MULTIDISCIPLINARY, DOCUMENTED ASSESSMENT PROCESS INTENDED TO PROACTIVELY IDENTIFY AND MITIGATE RISKS FROM INFECTION THAT COULD OCCUR DURING CONSTRUCTION ACTIVITIES. THIS PROCESS IDENTIFIES AND TAKES INTO ACCOUNT THE PATIENT POPULATION AT RISK, THE NATURE AND SCOPE OF THE PROJECT, AND THE FUNCTIONAL PROGRAM OF THE HEALTH CARE FACILITY. THE ICRA DETERMINES THE POTENTIAL RISK OF TRANSMISSION OF VARIOUS AIR- AND WATERBORNE BIOLOGICAL CONTAMINANTS IN THE FACILITY. ICRA TIMING AN ICRA SHALL BE CONDUCTED BEFORE CONSTRUCTION BEGINS, AND CONTINUE THROUGH PROJECT CONSTRUCTION AND COMMISSIONING. ICRA TEAM AT MINIMUM, AN ICRA SHALL BE CONDUCTED BY A TEAM WITH EXPERTISE IN INFECTION PREVENTION AND CONTROL, DIRECT PATIENT CARE (CLINICAL USE OF RELEVANT AREAS), FACIL- ITY DESIGN, CONSTRUCTION, AND HVAC AND PLUMBING SYSTEMS WHEN THESE SYSTEMS ARE INVOLVED. THE SCOPE AND NATURE OF THE PROJECT SHALL DICTATE OTHERS TO BE INVOLVED. ICRA CONSIDERATIONS THE ICRA SHALL ADDRESS, BUT NOT BE LIMITED TO COVERING, THE FOLLOWING: • NUMBER, LOCATION, AND TYPE OF AIRBORNE INFECTION ISOLATION AND PROTECTIVE ENVIRONMENT ROOMS. • NUMBER, LOCATION, AND TYPE OF PLUMBED HAND-WASHING STATIONS, HAND SANITATION DISPENSERS, AND EMERGENCY FIRST-AID EQUIPMENT (EYEWASH STATIONS AND DELUGE SHOWERS). (1) THE NUMBER AND LOCATION OF HAND-WASHING STATIONS AND HAND SANITATION DISPENSERS SHALL BE DETERMINED BY THE FUNCTIONAL PROGRAM AND THE ICRA. (2) HAND-WASHING STATIONS SHALL BE CONVENIENT AND ACCESSIBLE FOR HEALTH CARE PERSONNEL AND OTHER USERS. • SPECIAL HVAC NEEDS TO MEET THE FUNCTIONAL PROGRAM AND ACCOMMODATE THE SERVICES (E.G., SURGICAL SERVICES, AIRBORNE INFECTION ISOLATION AND PRO- TECTIVE ENVIRONMENT ROOMS, LABORATORIES, PHARMACIES, LOCAL EXHAUST SYSTEMS FOR HAZARDOUS AGENTS, AND OTHER SPECIAL AREAS) INCLUDED IN OR AFFECTED BY THE PROJECT • WATER SYSTEMS TO LIMIT LEGIONELLA SP. AND WATERBORNE OPPORTUNISTIC PATHOGENS WHEN CONDUCTING THE ICRA AND DEVELOPING THE INFECTION CONTROL RISK MITIGATION REQUIREMENTS FOR BUILDING AND SITE AREAS ANTICIPATED TO BE AFFECTED BY CONSTRUC- TION, THE FOLLOWING SHALL BE ADDRESSED: • THE IMPACT OF DISRUPTING ESSENTIAL SERVICES TO PATIENTS AND EMPLOYEES • DETERMINATION OF THE SPECIFIC HAZARDS AND PROTECTION LEVELS FOR EACH DESIGNATED AREA • LOCATION OF PATIENTS ACCORDING TO THEIR SUSCEPTIBILITY TO INFECTION AND THE DEFINITION OF RISKS TO EACH • IMPACT OF MOVEMENT OF DEBRIS, TRAFFIC FLOW, SPILL CLEANUP, AND TESTING AND CERTIFICATION OF INSTALLED SYSTEMS • ASSESSMENT OF EXTERNAL AS WELL AS INTERNAL CONSTRUCTION ACTIVITIES • LOCATION OF KNOWN HAZARDS ICRA DOCUMENTATION THIS WRITTEN RECORD SHALL REMAIN AN ACTIVE PART OF THE PROJECT DOCUMENTS FOR THE DURATION OF THE CONSTRUCTION PROJECT AND THROUGH COMMISSIONING. • THESE WRITTEN PLANS SHALL DESCRIBE THE SPECIFIC METHODS BY WHICH TRANSMISSION OF AIR- AND WATERBORNE BIOLOGICAL CONTAMINANTS WILL BE AVOIDED DURING CONSTRUCTION AS WELL AS DURING COMMISSIONING, WHEN HVAC AND PLUMBING SYSTEMS AND EQUIPMENT (E.G., ICE MACHINES, STEAM STERILIZATION SYSTEMS) ARE STARTED/RESTARTED. INFECTION CONTROL RISK MITIGATION RECOMMENDATIONS INFECTION CONTROL RISK MITIGATION RECOMMENDATIONS (ICRMRS) SHALL BE PREPARED BY THE ICRA TEAM AND SHALL, AT MINIMUM, ADDRESS THE FOLLOWING: 1. PATIENT PLACEMENT AND RELOCATION • STANDARDS FOR BARRIERS AND OTHER PROTECTIVE MEASURES REQUIRED TO PROTECT ADJACENT AREAS AND SUSCEPTIBLE PATIENTS FROM AIRBORNE CONTAMINANTS • TEMPORARY PROVISIONS OR PHASING FOR CONSTRUCTION OR MODIFICATION OF HVAC AND WATER SUPPLY SYSTEMS • PROTECTION FROM DEMOLITION • MEASURES TO BE TAKEN TO TRAIN HOSPITAL STAFF, VISITORS, AND CONSTRUCTION PERSONNEL • THE IMPACT OF POTENTIAL UTILITY OUTAGES OR EMERGENCIES, INCLUDING PROTECTION OF PATIENTS DURING PLANNED AND UNPLANNED UTILITY OUTAGES. SPECIFIC HAZARDS THAT ARE LIKELY IN THE EVENT OF DIFFERENT TYPES OF ESSENTIAL SERVICE DISRUPTIONS SHOULD BE PROACTIVELY DETERMINED. A PLAN SHOULD BE DEVELOPED TO ENSURE CONTINUED PROVISION OF SERVICE IN THE EVENT OF PLANNED AND UNPLANNED DISRUPTIONS. • THE IMPACT OF MOVEMENT OF DEBRIS, TRAFFIC FLOW, CLEANUP, ELEVATOR USE FOR CONSTRUCTION MATERIALS AND CONSTRUCTION WORKERS, AND CONSTRUCTION WORKER ROUTES 2. VENTILATION OF THE CONSTRUCTION ZONE • AIRFLOW INTO THE CONSTRUCTION ZONE FROM OCCUPIED SPACES SHOULD BE MAINTAINED BY MEANS OF A DEDICATED VENTILATION/EXHAUST SYSTEM FOR THE CONSTRUCTION AREA. ENSURE PROPER OPERATION OF THE AIR-HANDLING SYSTEM IN THE AFFECTED AREA AFTER ERECTION OF BARRIERS AND BEFORE THE ROOM OR AREA IS SET TO NEGATIVE PRESSURE • LOCATIONS OF EXHAUST DISCHARGE RELATIVE TO EXISTING FRESH AIR INTAKES AND FILTERS, AS WELL AS THE DISCONNECTION AND SEALING OF EXISTING AIR DUCTS, SHOULD BE REVIEWED AS REQUIRED BY THE ICRA. • IF THE EXISTING BUILDING SYSTEM OR A PORTION THEREOF IS USED TO ACHIEVE THIS REQUIREMENT, THE SYSTEM SHOULD BE THOROUGHLY CLEANED PRIOR TO OCCUPANCY OF THE CONSTRUCTION AREA. • HOSPITAL CONSTRUCTION BARRIERS FOR PROJECTS IN HIGH-RISK AREAS SHOULD BE MAINTAINED AT A PRESSURE DIFFERENTIAL OF AT LEAST 0.03 INCH WATER GAUGE (7.0 PASCALS), WITH AIRFLOW FROM HOSPITAL CLEAN AREAS TO CONSTRUCTION DIRTY AREAS. CONSTRUCTION BARRIERS IN HIGH-RISK AREAS SHOULD HAVE VISUAL DISPLAY OF AIRFLOW DIRECTION. (HIGH-RISK AREAS INCLUDE CRITICAL CARE UNITS, EMERGENCY ROOMS, LABOR AND DELIVERY FACILITIES, NEWBORN NURSERIES, OUTPATIENT SURGERY FACILITIES, AREAS SERVING PEDIATRIC PATIENTS, PHARMACIES, SURGICAL UNITS, POST-ANESTHETIC CARE UNITS, AREAS SERVING IMMUNOCOMPROMISED PATIENTS, BURN UNITS, CARDIAC CATHETERIZATION LABS, CENTRAL STERILE SUPPLY, AIRBORNE INFECTION ISOLATION ROOMS, PROTECTIVE ENVIRONMENT ROOMS, ONCOLOGY UNITS, OPERATING ROOMS, AND CESAREAN DELIVERY ROOMS.) MONITOR BARRIERS AND ENSURE INTEGRITY OF THE CONSTRUCTION BARRIERS; REPAIR GAPS OR BREAKS IN BARRIER JOINTS 3. DISASTER PLANS FOR WATER SUPPLY AND VENTILATION EMERGENCIES • THE OWNER SHOULD PROVIDE A WRITTEN PLAN FOR WHAT WILL HAPPEN IN THE EVENT OF A WATER OUTAGE. THIS SHOULD INCLUDE WHERE SUPPLIES ARE, WHO IS RESPONSIBLE FOR WHAT, AND WHO IS TO BE NOTIFIED. • THE OWNER SHOULD PROVIDE A WRITTEN PLAN FOR WHAT WILL HAPPEN IN THE EVENT OF AN AIR SHUTDOWN. THIS SHOULD INCLUDE WHO IS RESPONSIBLE FOR WHAT AND WHO IS TO BE NOTIFIED. • THE OWNER SHOULD PROVIDE A WRITTEN PLAN FOR WHAT WILL HAPPEN IN THE EVENT OF A WATER LEAK. THIS SHOULD INCLUDE WHO IS TO BE NOTIFIED. 4. CONSTRUCTION WORK ZONE PROTECTION • CONSTRUCTION MATERIALS SHOULD BE KEPT CLEAN AND DRY, AS APPROPRIATE. • DUCTWORK SHOULD BE KEPT CAPPED/CLEAN DURING DEMOLITION AND DUST- GENERATING CONSTRUCTION. • DRYWALL INSTALLATION SHOULD NOT PROCEED UNTIL EXTERIOR PROTECTION AGAINST RAIN DAMAGE HAS BEEN INSTALLED. • CONSTRUCT BARRIERS TO PREVENT DUST FROM CONSTRUCTION AREAS FROM ENTERING PATIENT-CARE AREAS; ENSURE THAT BARRIERS ARE IMPERMEABLE TO FUNGAL SPORES AND IN COMPLIANCE WITH LOCAL FIRE CODES • SEAL OFF AND BLOCK RETURN AIR VENTS IF RIGID BARRIERS ARE USED FOR CONTAINMENT • IMPLEMENT DUST-CONTROL MEASURES ON SURFACES AND DIVERT PEDESTRIAN TRAFFIC AWAY FROM WORK ZONES. • CLEAN WORK ZONES AND THEIR ENTRANCES DAILY BY : 1) WET-WIPING TOOLS AND TOOL CARTS BEFORE THEIR REMOVAL FROM THE WORK ZONE 2) PLACING MATS WITH TACKY SURFACES INSIDE THE ENTRANCE 3) COVERING DEBRIS AND SECURING THIS COVERING BEFORE REMOVING DEBRIS FROM THE WORK ZONE • IN PATIENT-CARE AREAS, FOR MAJOR REPAIRS THAT INCLUDE REMOVAL OF CEILING TILES AND DISRUPTION OF THE SPACE ABOVE THE FALSE CEILING, USE PLASTIC SHEETS OR PREFABRICATED PLASTIC UNITS TO CONTAIN DUST; USE A NEGATIVE PRESSURE SYSTEM WITHIN THIS ENCLOSURE TO REMOVE DUST; AND EITHER PASS AIR THROUGH AN INDUSTRIAL-GRADE, PORTABLE HEPA FILTER CAPABLE OF FILTRATION RATES OF 300 - 800 FT3/MIN., OR EXHAUST AIR DIRECTLY TO THE OUTSIDE • UPON COMPLETION OF THE PROJECT, CLEAN THE WORK ZONE ACCORDING TO FACILITY PROCEDURES, AND INSTALL BARRIER CURTAINS TO CONTAIN DUST AND DEBRIS BEFORE REMOVING RIGID BARRIERS. FLUSH THE WATER SYSTEM TO CLEAR SEDIMENT FROM PIPES TO MINIMIZE WATERBORNE MICROORGANISM PROLIFERATION. RESTORE APPROPRIATE ACH, HUMIDITY, AND PRESSURE DIFFERENTIAL; CLEAN OR REPLACE AIR FILTERS; DISPOSE OF SPENT FILTERS 5. PROVIDE CONSTRUCTION CREWS WITH • DESIGNATED ENTRANCES, CORRIDORS, AND ELEVATORS WHEREVER PRACTICAL • ESSENTIAL SERVICES (E.G., TOILET FACILITIES) AND CONVENIENCE SERVICES (E.G., VENDING MACHINES) • PROTECTIVE CLOTHING (E.G., COVERALLS, FOOTGEAR, AND HEADGEAR) FOR TRAVEL TO PATIENT-CARE AREAS • A SPACE OR ANTEROOM FOR CHANGING CLOTHING AND STORING EQUIPMENT MONITORING PLAN AND PROCEDURES (1) THE OWNER SHALL PROVIDE MONITORING PLANS FOR EFFECTIVE APPLICATION OF ICRMRS DURING THE COURSE OF THE PROJECT. (2) PROVISIONS FOR MONITORING SHALL INCLUDE WRITTEN PROCEDURES FOR EMERGENCY SUSPENSION OF WORK AND PROTECTIVE MEASURES INDICATING THE RESPONSIBILITIES AND LIMITATIONS OF EACH PARTY (OWNER, DESIGNER, CONTRACTOR, AND MONITOR). • RESPONSIBILITIES OF PERSONS AND GROUPS FOR PROCEDURES AND ACTIVITIES TO BE PERFORMED TO MITIGATE RISK SHOULD BE INCLUDED IN INFECTION CONTROL RISK MITIGATION PLANS TO ENSURE THE PROPER ACTIONS ARE TAKEN AT THE PROPER TIME. • MONITORING EFFORTS WILL BE DETERMINED BY THE OWNER AND MAY BE CONDUCTED BY THE OWNER’S INFECTION PREVENTIONIST(S), EPIDEMIOLOGIST, CONSTRUCTION COORDINATORS, AND/OR SAFETY STAFF OR BY INDEPENDENT OUTSIDE CONSULTANTS. COMMUNICATION (1) UPDATES ON ICRA COMPLIANCE SHALL BE PROVIDED BY THE ICRA TEAM. (2) CHANGES TO THE ORIGINAL DESIGN PLANS SHALL BE DOCUMENTED, UPDATED, AND CONTINUOUSLY SHARED BETWEEN THE ICRA TEAM AND THE DESIGNERS/ ARCHITECTS/PLANNERS, OWNER, AND CONTRACTOR. THE CONTRACTOR SHALL PREPARE SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS AND SUBMIT TO THE ARCHITECT OR ENGINEER OF RECORD FOR REVIEW PRIOR TO SUBMITTAL TO THE AGENCY HAVING JURISDICTION (AHJ) FOR APPROVAL. INSTALLATION OF DEFERRED APPROVAL SHALL NOT BE STARTED UNTIL DOCUMENTS HAVE BEEN REVIEWED BY THE ARCHITECT OR ENGINEER AND APPROVED BY THE AHJ. DEFERRED ITEMS ARE TO BE COMPLETELY INSTALLED PRIOR TO OCCUPANCY OF BUILDING(S) AND/ OR AREAS AFFECTED BY THE DEFERRED WORK. DEFERRED APPROVALS: 1. FIRE ALARM DESIGN - REWORK EXISTING SYSTEM TO CONFORM TO NEW SPACE CONFIGURATION. ADD DEVICES AS NECESSARY FOR NEW ROOMS. MATCH DEVICES TO MANUFACTURER OF CURRENT SYSTEM. 2. FIRE SPRINKLER DESIGN - REWORK EXISTING SYSTEM TO CONFORM TO NEW SPACE CONFIGURATION. RELOCATE HEADS TO COVER THE AREAS AS NEEDED. BRANCH MODIFICATIONS ONLY, ALL MAIN LINES ARE EXISTING TO REMAIN. MATCH TYPE, STYLE, AND FINISH OF EXISTING SPRINKLER HEADS. INT ER S TA TE 5 FOURTH STREET FIRST STREET GO L D E N C I R C L E D R . CA B R I L L O P A R K D R . SITE LOCATION N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHI TE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO: FLOOR LEV: SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. HISTORY LOG Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C: \ U s e r s \ jp a r k \ D o c u m e n t s \ R 3 14 4 1 2 . 4 4 - K P S A N 1s t F l r G e n R a d _ A 2 2_ C e n t r a l _ j h a L W M Q W. r v t 7/ 3 / 2 0 2 4 8 :0 9 : 0 3 A M SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) G0-01 TITLE SHEET CA361 1 1 - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 1900 E. 4TH ST. SANTA ANA, CA 92701 KP NO.CAP028060 SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) N/A SYMBOLS LEGEND 11 N/A DRAWING SET ORGANIZATION 21 N/A PROJECT TEAM 01 02N/A SHEET INDEX N/A GENERAL NOTES 22 N/A PROJECT SUMMARY 09 N/A INFECTION CONTROL NOTES 16 GENERAL G0-01 TITLE SHEET G0-02 SPECIFICATIONS G0-03 SPECIFICATIONS G0-04 SPECIFICATIONS G0-05 SPECIFICATIONS G1-00 PLAN - SITE ACCESSIBLITY G1-11 PLAN - CODE ANALYSIS 1ST FLR STRUCTURAL S0-01 GENERAL NOTES S1-13 PLAN - REMODEL 1ST FLR S5-01 DETAILS S5-02 DETAILS ARCHITECTURAL A0-11 PLAN - DEMO OVERALL 1ST FLR A0-12 PLAN - DEMO OVERALL RCP 1ST FLR A0-13 PLAN - DEMO 1ST FLR A0-14 PLAN - DEMO CONCRETE 1ST FLR A1-11 PLAN - REMODEL OVERALL 1ST FLR A1-12 PLAN - REMODEL OVERALL RCP 1ST FLR A1-13 PLAN - REMODEL 1ST FLR A1-14 PLAN - REMODEL ENLARGED - DIMENSION & PARTITION TYPE A2-01 ELEVATIONS - INTERIOR A2-02 ELEVATIONS - INTERIOR A2-03 ELEVATIONS - INTERIOR A5-01 DETAILS - PARTITION TYPES A5-02 DETAILS - TYPICAL FRAMING A5-03 DETAILS - MISC. A5-04 DETAILS - TYPICAL CEILING A6-01 SCHEDULE - DOOR INTERIORS I1-11 PLAN - FINISH 1ST FLR EQUIPMENT AND FURNITURE Q1-11 PLAN - EQUIPMENT & FURNITURE Q7-01 IMAGING EQUIPMENT VENDOR DRAWINGS RM 1507 (FOR REFERENCE ONLY) Q7-02 IMAGING EQUIPMENT VENDOR DRAWINGS RM 1507 (FOR REFERENCE ONLY) Q7-03 IMAGING EQUIPMENT VENDOR DRAWINGS RM 1507 (FOR REFERENCE ONLY) Q7-04 IMAGING EQUIPMENT VENDOR DRAWINGS RM 1507 (FOR REFERENCE ONLY) Q7-05 IMAGING EQUIPMENT VENDOR DRAWINGS RM 1507 (FOR REFERENCE ONLY) Q8-11 PLAN - SHIELDING RM 1507 PLUMBING P0-01 GENERAL NOTES, LEGEND & SYMBOLS P0-02 SPECIFICATIONS - PLUMBING P0-11 PLAN - DEMO OVERALL 1ST FLR P0-12 PLAN - DEMO 1ST FLR P1-11 PLAN - REMODEL OVERALL 1ST FLR P1-12 PLAN - REMODEL 1ST FLR P6-01 DETAILS & SCHEDULES - PLUMBING MECHANICAL M0-01 GENERAL NOTES, LEGEND & SYMBOLS M0-02 SPECIFICATIONS - MECHANICAL M0-11 PLAN - DEMO OVERALL 1ST FLR M0-12 PLAN - DEMO 1ST FLR M1-11 PLAN - REMODEL OVERALL 1ST FLR M1-12 PLAN - REMODEL 1ST FLR M5-01 DETAILS - MECHANICAL ELECTRICAL E0-01 GENERAL NOTES, ABBREVIATIONS AND SYMBOLS LIST E0-02 SPECIFICATIONS E1-11 PLAN - OVERALL 1ST FLR E1-12 PLAN - ENLARGED - DEMO - 1ST FLOOR E1-13 PLAN - ENLARGED - REMODEL - 1ST FLOOR E5-00 VENDOR DRAWINGS E5-01 DETAILS - ELECTRICAL E6-01 PARTIAL SINGLE LINE DIAGRAMS, PANEL SCHEULDE, & LIGHT FIXTURE SCHEDULE E6-02 SINGLE LINE DIAGRAM E7-01 TITLE 24 SECURITY T1-11 PLAN - REMODEL 1ST FLR - SECURITY T1-21 PLAN - 2ND FLR - SECURITY T5-01 DETAILS - SECURITY SIGNAGE SG1-11 SIGNAGE - PLAN SG5-01 DETAILS - SIGNAGE GRAND TOTAL: 64 N/A DEFERRED APPROVALS 06 NTS VICINITY MAP 13 GENERAL PROVISIONS 1. ALL WORK SHALL CONFORM TO THE CURRENT EDITIONS OF NATIONAL, STATE AND LOCAL CODES, AND OTHER REGULATORY AGENCIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK. ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING GENERAL CONSTRUCTION, MECHANICAL, ELECTRICAL, PLUMBING, OR RELATED WORK SHALL COMPLY WITH APPLICABLE SECTIONS OF THE CODES THAT HAVE JURISDICTION, INCLUDING BUT NOT LIMITED TO: 2022 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE (CAC) CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 1 2022 CALIFORNIA BUILDING CODE (CBC) CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 2 (2021 INTERNATIONAL BUILDING CODE WITH CALIFORNIA AMENDMENTS) 2022 CALIFORNIA ELECTRICAL CODE (CEC) CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 3 (2020 NATIONAL ELECTRICAL CODE WITH CALIFORNIA AMENDMENTS) 2022 CALIFORNIA MECHANICAL CODE (CMC) CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 4 (2021 UNIFORM MECHANICAL CODE WITH CALIFORNIA AMENDMENTS) 2022 CALIFORNIA PLUMBING CODE (CPC) CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 5 (2021 UNIFORM PLUMBING CODE WITH CALIFORNIA AMENDMENTS) 2022 CALIFORNIA ENERGY CODE CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 6 2022 CALIFORNIA FIRE CODE (CFC) CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 9 (2021 INTERNATIONAL FIRE CODE WITH CALIFORNIA AMENDMENTS) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN CODE) CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 11 TITLE 19, CALIFORNIA CODE OF REGULATIONS (CCR) DIVISION 1, STATE FIRE MARSHAL REGULATIONS 2022 CALIFORNIA BUILDING CODE CHAPTER 35 REFERENCE STANDARDS NFPA 13-22: STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS NFPA 72-22: NATIONAL FIRE ALARM AND SIGNAL CODE WITH CALIFORNIA AMENDMENTS 2. ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE REQUIREMENTS OF THESE CODES AND ALL APPLICABLE LOCAL ORDINANCES. WHERE CONTRACT DOCUMENTS EXCEED SUCH REQUIREMENTS, WITHOUT VIOLATING SUCH CODES, REGULATIONS AND ORDINANCES, CONTRACT DOCUMENTS TAKE PRECEDENCE. WHERE CODES CONFLICT, THE MORE STRINGENT SHALL APPLY. 07 N/A APPLICABLE CODES CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 PLAN CHECK CORRECTIONS 07/02/2024 Bldg# 101119067 APPROVALS: PLNG - JHeidi BLDG - CSG Consultants 1900 E 4th St - 1011190678/9/2024 DIVISION 1 - GENERAL REQUIREMENTS SECTION 01 1100 - SUMMARY OF WORK - THIS PROJECT INVOLVES THE RELOCATION OF AN EXISTING IMAGING RADIOLOGY ROOM INTO AN EXISTING CONTROL ROOM. THE EXISTING DRESSING ROOMS WILL BE DEMOLISHED AND REBUILT TO ACCOMODATE THE NEW LOCATION OF THE IMAGING RADIOLOGY ROOM. THE EXISTING LOCATION OF THE IMAGING RADIOLOGY ROOM WILL BE CONVERTED INTO A SHELL SPACE. SECTION 01 2500 - SUBSTITUTIONS - NO PRODUCT MAY BE SUBSTITUTED WITHOUT A PRIOR SUBMITTAL TO AND APPROVAL BY THE ARCHITECT. - PRODUCTS DEEMED NOT AS AN "EQUAL"OR "BETTER" THAN THE SPECIFIED PRODUCT MAY NOT BE SUBSTITUTED. - IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THAT SUCH SUBSTITUTION IS "EQUAL" OR "BETTER" PRIOR TO THE SUBMITTAL. - THE ARCHITECT/ ENGINEER TIME AND FEES REQUIRED TO REVIEW SUBSTITUTIONS SHALL BE PAID BY THE CONTRACTOR. - REVIEW OF SUBSTITUTION SHALL PROCEED UPON AGREEMENT AND APPROVAL OF FEES. - SUBSTITUTION SUBMITTALS CONSTITUTE USING UNNAMED MANUFACTURERS AS 'OR EQUALS" - REQUEST FOR SUBSTITUTION SHALL BE REVIEWED BY THE CONTRACTOR AS EQUAL OR BETTER THAN SPECIFIED PRODUCT PRIOR TO SUBMITTAL. - ANY ADDITIONAL COST AS A RESULT OF A SUBSTITUTION SHALL BE BORNE BY THE CONTRACTOR. - UNAUTHORIZED AND UNAPPROVED SUBSTITUTION MATERIAL SHALL BE REMOVED FROM THE SITE AND REPLACED WITH SPECIFIED MATERIAL AT NO ADDITIONAL COST TO THE OWNER. SECTION 01 3119 - PROJECT MEETINGS - UNLESS OTHERWISE REQUIRED BY THE OWNER, BI-WEEKLY CONSTRUCTION MEETINGS SHALL BE ATTENDED BY THE OWNER, ARCHITECT AND CONTRACTOR. - THE CONTRACTOR SHALL WRITE THE MEETING RECORDS. - THE PURPOSE OF THE MEETING INCLUDES PROJECT PROGRESS, REVIEW OF SCHEDULE AND PROJECT VALUES, INSPECTION PROGRESS SECTION 01 3200 - CONSTRUCTION PROGRESS DOCUMENTATION - WITHIN 5 DAYS OF CONTRACT AWARD, THE CONTRACTOR SHALL PROVIDED PROJECT SCHEDULE IDENTIFYING THE FOLLOWING: - SEQUENCE OF CONSTRUCTION - LONG LEAD ITEMS - CONSTRUCTION START DATE - SUBMITTAL DATES - DELIVERY DATES - PERCENT OF COMPLETION - FINAL COMPLETION DATE - THE SCHEDULE SHALL BE REVIEWED AT EACH CONSTRUCTION MEETING SECTION 01 3300 - SUBMITTAL PROCEDURES - CONTRACTOR SHALL LABEL, REVIEW AND NOTE CHANGES ON SUBMITTALS PRIOR TO SUBMITTING TO THE ARCHITECT. - WHEN POSSIBLE, SUBMITTAL SHALL BE SUBMITTED DIGITALLY. IF SUBMITTALS CANNOT BE SUBMITTED DIGITALLY THEN: - SUBMIT SIX (6) SETS OF MANUFACTURER'S PRODUCT DATA, MATERIAL SAFETY DATA SHEETS (MSDS), SHOP DRAWINGS AND SAMPLES FOR ARCHITECT'S APPROVAL. - THE ARCHITECT SHALL PROCESS SUBMITTAL WITHIN 10 (TEN) DAYS OF SUBMITTAL RECEIPT. SECTION 01 3543 - ENVIRONMENTAL PROCEDURES - COMPLY WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS PERTAINING TO WATER, AIR, SOLID WASTE AND NOISE POLLUTION. SECTION 01 4100 - REGULATORY REQUIREMENTS - PERFORM ALL WORK IN ACCORDANCE TO THE LATEST ENFORCED STATUTES, ORDINANCES, LAWS, RULES, CODES, REGULATIONS STANDARDS AND LAWFUL ORDERS OF ALL PUBLIC AUTHORITIES HAVING JURISDICTION. SECTION 01 4500 - QUALITY CONTROL - PRIOR TO INSTALLATION OF ANY WORK, THE CONTRACTOR SHALL INSPECT THE WORK CONDITIONS AND ARRANGE FOR CORRECTION AS REQUIRED OF DEFECTIVE WORKMANSHIP OR MATERIAL THAT MAY AFFECT THE WORK TO BE INSTALLED. - INSTALLATION OF NEW WORK CONSTITUTES ACCEPTANCE THAT THE WORK IN PLACES IS IN PROPER CONDITIONS AND WAIVER OF CLAIM THAT THE WORK IN PLACE IS DEFECTIVE. - ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE ATTACHED SPECIFICATIONS AND CONSTRUCTION DOCUMENTS. - UNLESS OTHERWISE NOTED, ALL MATERIALS AND PRODUCTS SHALL BE NEW AND SPECIFICALLY FOR THE USE IN THIS PROJECT. - UNLESS OTHERWISE NOTED, CONSTRUCTION COST SHALL INCLUDE LABOR AND MATERIALS. SECTION 01 4523 - TESTING AND INSPECTING SERVICES - THE OWNER WILL EMPLOY AND PAY FOR INDEPENDENT TESTING SERVICES. - TESTING AND INSPECTING SERVICES ARE REQUIRED TO VERIFY COMPLIANCE WITH REQUIREMENTS SPECIFIED OR INDICATED. THESE SERVICES DO NOT RELIEVE CONTRACTOR OF RESPONSIBILITY FOR COMPLIANCE WITH THE CONTRACT DOCUMENT REQUIREMENTS. - SPECIFIED TESTS, INSPECTIONS, AND RELATED ACTIONS DO NOT LIMIT CONTRACTOR'S OTHER QUALITY-ASSURANCE AND -CONTROL PROCEDURES THAT FACILITATE COMPLIANCE WITH THE CONTRACT DOCUMENT REQUIREMENTS. - THE CONTRACTOR SHALL REIMBURSE THE OWNER FOR EXCESSIVE INSPECTION COSTS INCURRED BY THE CONTRACTOR'S FAILURE TO COMPLETE THE WORK TIMELY, DEFECTIVE WORK, OVERTIME FOR THE CONTRACTOR'S CONVENIENCE. - THE CONTRACTOR SHALL PAY INSPECTION COSTS FOR ADDITIONAL TESTING DUE TO FAILURE OF MATERIALS, TESTING TO SUBSTANTIATE PROPOSED SUBSTITUTIONS, AND IF APPLICABLE, TESTING TO DETERMINE CODE COMPLIANCE FOR CONCRETE MIX DESIGNS. - THE CONTRACTOR SHALL FURNISH ALL SAMPLES FOR TESTING AS REQUIRED. INITIATE AND COORDINATE ALL TESTING INSPECTIONS AS REQUIRED IN THE CBC, TITLE 24 AND CONSTRUCTION DOCUMENTS. - EACH SIGNED AND CERTIFIED TESTING REPORT SHALL BE COPIED TO THE OWNER, CONTRACTOR AND INSPECTOR OF RECORD. - THE OWNER RESERVES THE RIGHT TO REJECT MATERIALS AND WORKMANSHIP WHICH ARE DEEMED DEFECTIVE OR REQUIRE CORRECTION. SECTION 01 5000 - TEMPORARY FACILITIES - REFER TO THE GENERAL CONDITIONS OR COORDINATE WITH THE OWNER FOR TEMPORARY FACILITIES SUCH AS POWER, WATER, TELEPHONE, SANITARY FACILITIES, FIRE AND SAFETY REQUIREMENTS, GUARDS AND BARRICADES. SECTION 01 6600 - PRODUCT STORAGE AND HANDLING REQUIREMENTS - TRANSPORT, DELIVER, HANDLE AND STORE MATERIALS AND EQUIPMENT AT THE JOB SITE IN A MANNER THAT WILL PREVENT DAMAGE, INCLUDING INTRUSIONS FROM FOREIGN MATTER AND MOISTURE. - MAINTAIN PACKAGED MATERIALS FROM MANUFACTURER'S ORIGINAL CONTAINER UNTIL SUCH TIME WHEN THEY WILL BE INSTALLED. - PROVIDE BARRICADE AND SECURITY AS REQUIRED TO PROTECT PRODUCT. - LOCAL REPRESENTATIVE FOR MAINTENANCE, REPAIR, REPLACEMENT. SECTION 01 7329 - CUTTING AND PATCHING - EXECUTE ALL CUTTING (INCLUDING EXCAVATION ), FITTING OR PATCHING TO MAKE PARTS FIT PROPERLY, TO MATCH EXISTING WHERE APPLICABLE, TO REMOVE AND/ OR REPLACE WORK NOT CONFORMING TO REQUIREMENTS OF THE CONTRACT DOCUMENTS. SECTION 01 7400 - CLEANING AND WASTE MANAGEMENT - PREMISES SHALL BE MAINTAINED CLEAN OF WASTE, DEBRIS AND RUBBISH AT ALL TIMES. - PROVIDE ON-SITE DUMP CONTAINERS DURING THE COURSE OF CONSTRUCTION. - AT FINAL CLEANING REMOVE ALL DEBRIS FROM SITE, REMOVE ALL STAINS, MARKS, PAINT SPOTS, DUST, AND OTHER BLEMISHES AND DEFECTS. - USE ONLY CLEANING MATERIALS RECOMMENDED BY MANUFACTURERS. SECTION 01 7800 - CLOSEOUT SUBMITTALS - SUBMIT WRITTEN NOTICE TO THE ARCHITECT WHEN THE PROJECT IS SUBSTANTIALLY COMPLETED WITH A LIST OF PENDING ITEMS. - THE ARCHITECT WILL THEN MAKE INSPECTION AND DETERMINE THE EXTENT OF THE SUBSTANTIAL COMPLETION. - ANY DEFICIENCIES AND / OR INCOMPLETE WORK SHALL BE CORRECTED PRIOR TO REQUEST OF FINAL COMPLETION. - WHEN THE WORK IS CONSIDERED COMPLETE, THE CONTRACTOR SHALL SUBMIT A WRITTEN CERTIFICATION THAT THE CONTRACT DOCUMENTS HAVE BEEN REVIEWED, THE WORK HAS BEEN INSPECTED AND COMPLETED FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS. - WHEN ACCEPTABLE, THE ARCHITECT WILL REQUEST THE CONTRACTOR TO SUBMIT PROJECT CLOSE-OUT. - FINAL CERTIFICATE OF PAYMENT WILL BE APPROVED AFTER THE CONTRACTOR DELIVERS THE REQUIRED WARRANTIES / GUARANTEES, FINAL CLEAN UP, PROJECT RECORD DOCUMENTS, OPERATION AND MAINTENANCE MANUALS, WATER PURITY REPORT AND CERTIFICATE OF OCCUPANCY. SECTION 01 78 23 - OPERATION AND MAINTENANCE DATA - THE CONTRACTOR SHALL PROVIDE THE OWNER WITH A BINDER WHICH INCLUDES ALL OPERATION MAINTENANCE MANUALS OF ALL PRODUCTS USED IN THE PROJECT. - DELIVER ALL SPECIAL TOOLS, INSTRUMENTS, ACCESSORIES AND SPARE PARTS FOR THE MAINTENANCE OF ALL PRODUCTS TO THE OWNER. SECTION 01 7836 - WARRANTIES - THE CONTRACTOR SHALL COLLECT ALL WRITTEN WARRANTIES AND GUARANTIES AND GUARANTEES INTO A BOUND BOOK AND DELIVER TO THE ARCHITECT FOR THE OWNER'S FINAL APPROVAL. - ASSEMBLE ALL MANUFACTURERS' WARRANTIES AND GUARANTEES WITH THE OWNER'S NAME AS THE BENEFICIARY , INCLUDING ALL EXTENDED WARRANTIES. - ALL WARRANTEES AND GUARANTEES, OTHER THAN MANUFACTURER'S PRINTED WARRANTEES AND GUARANTEES, SHALL BE SUBMITTED IN THE CONTRACTOR'S, SUB-CONTRACTOR, MATERIALS, SUPPLIER OR MANUFACTURER'S LETTERHEAD, STATING THE FOLLOWING INFORMATION: - WARRANTY / GUARANTEE FOR - NAME OF THE OWNER - CONTRACTOR / SUBCONTRACT / SUPPLIER / MFR'S NAME - CONTACT NAME - STATE LICENSE NO. - LOCAL REPRESENTATIVE FOR MAINTENANCE, REPAIR, REPLACEMENT SECTION 01 7839 - PROJECT RECORD DOCUMENTS - THE CONTRACTOR SHALL MAINTAIN ON SITE A SET OF CONSTRUCTION DOCUMENTS FOR THE PURPOSE OF RECORDING AS-BUILT CONDITIONS. - AT THE END OF THE PROJECT, ALL AS-BUILT DRAWINGS SHALL BE TURNED OVER TO THE ARCHITECT FOR THE PRODUCTION OF RECORD DRAWINGS. - THE ARCHITECT WILL ISSUE TO THE OWNER ONE (1) ELECTRONIC FILE OF THE RECORD DRAWINGS. DIVISION 2 - EXISTING CONDITIONS SECTION 02 4119 - SELECTIVE DEMOLITION - EXAMINE THE AREA AND CONDITIONS WHERE DEMOLITION IS TO OCCUR. - IDENTIFY EXTENT OF SELECTIVE DEMOLITION AND ORGANIZE PLAN FOR DEMOLITION AND REMOVAL. - CORRECT ANY UNSATISFACTORY CONDITIONS PRIOR TO PROCEEDING WITH WORK. - ANY UTILITY SHUT OFF SHALL BE COORDINATED WITH THE OWNER AND NOTIFY THE OWNER IN WRITING A MIN. OF 7 DAYS IN ADVANCE. - MATERIALS RESULTING FROM DEMOLITION THAT ARE NOT WANTED BY THE OWNER BECOME THE PROPERTY OF THE CONTRACTOR, EXCEPT AS FOLLOWS, AND SHALL BE PROMPTLY REMOVED FROM THE PROJECT SITE. STORAGE OR SALE OF REMOVED MATERIALS WILL NOT BE PERMITTED ON PROJECT SITE OR WITHIN BUILDING. ITEMS NOT BECOMING PROPERTY OF THE CONTRACTOR INCLUDE, BUT ARE NOT NECESSARILY LIMITED TO THE FOLLOWING: - OWNER HAS FIRST SALVAGE RIGHTS TO FIXTURES, EQUIPMENT, ACCESSORIES AND DOORS REMOVED. ITEMS NOT WANTED BY THE OWNER ARE TO BE DISCARDED OFF-SITE BY CONTRACTOR. - EQUIPMENT BELONGING TO UTILITY OR PUBLIC SERVICE COMPANIES UNLESS ABANDONED BY SUCH COMPANIES. - HIDDEN VALUABLE ITEMS, BURIED ITEMS AND PROPERTY OF THIRD PERSONS. - SALVAGED EQUIPMENT AND MATERIALS NOTED FOR REUSE. OTHER ITEMS INDICATED OR OTHERWISE IDENTIFIED BY OWNER OR ARCHITECT - DURING DEMOLITION OPERATIONS, SHOULD SUSPECT ASBESTOS OR ASBESTOS-CONTAINING MATERIALS, OR OTHER MATERIAL LISTED AS A HAZARDOUS MATERIAL BY THE ENVIRONMENTAL PROTECTION AGENCY (EPA) BE DISCOVERED, NOTIFY THE OWNER AND ARCHITECT AND DISCONTINUE THAT PORTION OF WORK UNTIL FURTHER INSTRUCTED. - CONDUCT DEMOLITION OPERATIONS AND THE REMOVAL OF DEBRIS TO ENSURE MINIMUM INTERFERENCE WITH ROADS, STREETS, WALKS AND ADJACENT FACILITIES. - DO NO CLOSE OR OBSTRUCT STREETS OR WALKS WITHOUT PERMISSION FROM AUTHORITIES HAVING JURISDICTION. PROVIDE FLAGMAN WHERE PUBLIC THOROUGHFARES ARE USED FOR DEBRIS REMOVAL. MAINTAIN THOROUGHFARES FREE OF DIRT AND DEBRIS CAUSED BY DEMOLITION OR HAULING OPERATIONS. - PROTECT PORTIONS OF EXISTING BUILDING INDICATED TO REMAIN. REPAIR OR REPLACE PORTIONS OF BUILDING DAMAGED BY THIS WORK, AT NO ADDITIONAL COST. - PROVIDE TEMPORARY ENCLOSURES OR OTHER METHODS TO LIMIT DUST TRANSMISSION TO ADJACENT AREAS. PROVIDE TEMPORARY NOISE REDUCTION BARRIERS TO SEPARATE WORK AREAS FROM ADJACENT OCCUPIED ARES. - ITEMS TO BE REMOVED AND STORED DURING THE CONSTRUCTION PROCESS AS INDICATED ON THE DRAWINGS SHALL BE STORED AT THE DIRECTION OF THE OWNER. - REMOVE CONSTRUCTION AND FINISHES AS REQUIRED FOR NEW CONSTRUCTION AND TO LIMITS INDICATED ON DRAWINGS. - DURING DEMOLITION, PROTECT ADJOINING WORK FROM DAMAGE. OBSERVE AND MONITOR ADJACENT STRUCTURAL ELEMENTS. STOP WORK AND NOTIFY ARCHITECT FOR INSTRUCTIONS IF CHANGES ARE NOTED. CRACKS OR STRUCTURAL DAMAGE RESULTING FROM DEMOLITION SHALL BE REPAIRED AT NO EXPENSE TO THE OWNER AND TO THE ARCHITECT'S/ENGINEER'S SATISFACTION. - REMOVE EXISTING FINISHES TO LIMITS INDICATED ON THE DRAWINGS WITHOUT DAMAGES TO SUBSTRATES OR ADJACENT SURFACES. INCLUDE REMOVAL OF MECHANICAL AND ELECTRICAL WORK AS APPLICABLE. - REMOVAL OF EXISTING RESILIENT FLOOR COVERINGS: REMOVE FLOOR COVERINGS AND ADHESIVE ACCORDING TO RECOMMENDATIONS IN RFCI'S "RECOMMENDED WORK PRACTICES FOR THE REMOVAL OF RESILIENT FLOOR COVERS." DO NOT USE METHODS REQUIRING SOLVENT-BASED ADHESIVE STRIPPERS. - WHERE WORK IS TO BE CUT OR REMOVED TO ACCOMMODATE NEW WORK, FORM NEAT, UNIFORM AND SMOOTH EDGES OR TERMINATIONS. - PREPARE AN ITEMIZED LIST OF MATERIAL OR EQUIPMENT FOR REUSE OR STORAGE. LIST QUANTITIES, CONDITION AND LOCATION. SUBMIT COPIES TO OWNER WITHIN SEVEN (7) DAYS OF REMOVAL OF ITEM. - REMOVE AND STORE (WHERE NOTED ON DRAWINGS) EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT, INCLUDING PLUMBING FIXTURES, AS INDICATED AND REQUIRED TO COMPLETE WORK. - REMOVE DEBRIS, RUBBISH AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS FROM PROJECT SITE. DO NOT STOCKPILE DEBRIS ON PROJECT SITE. - BURNING OF REMOVED MATERIALS FROM DEMOLISHED STRUCTURES WILL NOT BE PERMITTED ON THE PROJECT SITE. - COMPLY WITH THE CITY'S REQUIREMENT FOR CONSTRUCTION WASTE RECYCLING. - REPAIR DENTS, CRACKS, SCRATCHES AND HOLES IN EXISTING FINISHES TO REMAIN AS PART OF THE FINISHED WORK. DIVISION 3 - CONCRETE (NO SECTIONS REQUIRED) DIVISION 4 - MASONRY (NO SECTIONS REQUIRED) DIVISION 5 - METALS (NO SECTIONS REQUIRED) SECTION 06 2000 - FINISH CARPENTRY AND MILLWORK PART 1 - GENERAL 1.1 SUMMARY: A. WORK OF THIS SECTION INCLUDES FACTORY-FABRICATED WOODWORK AS FOLLOWS: 1. PLASTIC LAMINATE-SURFACED COUNTERS, BASE CABINETS, LOW WALLS, WALL CABINETS, AND OPEN SHELVING. 2. ROUGH AND FINISHED HARDWARE FOR THIS WORK. 1.2 SUBMITTALS: A. GENERAL: IN COMPLIANCE WITH SECTION 01 3300 AND AS SPECIFIED HEREIN. B. SHOP DRAWINGS: SUBMIT FOR ARCHITECTURAL WOODWORK. INDICATE CONSTRUCTION AND INSTALLATION DETAILS, SPECIES AND GRADES OF MATERIALS, FINISHES, AND CABINET HARDWARE SELECTIONS. C. PRODUCT DATA: SUBMIT FOR CABINET HARDWARE AND SIMILAR MANUFACTURED ITEMS. SUBMIT WITH SHOP DRAWINGS. D. SAMPLES; SUBMIT AS FOLLOWS: 1. FINISH SAMPLES: SUBMIT ONE SAMPLE OF EACH TYPE OF SELECTED FINISH ON SAMPLES OF SPECIES AND GRADE MATERIAL SPECIFIED. 2. HARDWARE ITEMS: SUBMIT IF REQUESTED BY ARCHITECT. SAMPLES WILL BE RETURNED TO SUPPLIER. E. FIRE-RETARDANT TREATMENT CERTIFICATION: SUBMIT FOR ARCHITECT'S INFORMATION ONLY. SUBMIT CERTIFICATION BY TREATING PLANT THAT FIRE RETARDANT TREATMENT MATERIALS COMPLY WITH GOVERNING ORDINANCES AND THAT TREATMENT WILL NOT BLEED THROUGH FINISHED SURFACES. F. AWI CERTIFICATION: SUBMIT AWI QUALITY CERTIFICATION PROGRAM CERTIFICATES INDICATING THAT THE WOODWORK PROVIDED FOR THIS PROJECT COMPLIES WITH THE REQUIREMENTS OF THE AWI GRADES SPECIFIED. 1.3 QUALITY ASSURANCE: A. APPLICABLE STANDARDS; COMPLY WITH THE FOLLOWING: 1. STANDARDS OF THE FOLLOWING, AS REFERENCED HEREIN: A. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). B. APA THE ENGINEERED WOOD ASSOCIATION (APA). C. ASTM INTERNATIONAL (ASTM). D. AMERICAN WOOD PROTECTION ASSOCIATION (AWPA). E. HARDWOOD PLYWOOD AND VENEER ASSOCIATION (HPVA). F. NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION (NEMA). G. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA). H. UNDERWRITERS LABORATORIES, INC., (UL). 2. WOOD PRODUCTS; STANDARDS OF THE U.S. DEPARTMENT OF COMMERCE, NATIONAL INSTITUTE OF STANDARDS AND TESTING: A. LUMBER: PS 20-10. B. CONSTRUCTION AND INDUSTRIAL PLYWOOD: PS 1-95 3. STANDARDS FOR ARCHITECTURAL WOODWORK: ARCHITECTURAL WOODWORK INSTITUTE (AWI), "ARCHITECTURAL WOODWORK QUALITY STANDARDS, GUIDE SPECIFICATIONS AND QUALITY CERTIFICATION PROGRAM," 2005 EDITION, HEREIN REFERRED TO AS AWI STANDARDS. WORK SHALL COMPLY WITH APPLICABLE PORTIONS OF AWI STANDARDS. B. GRADE MARKS: IDENTIFY LUMBER AND PLYWOOD BY OFFICIAL GRADE MARK. 1. LUMBER: GRADE STAMP SHALL CONTAIN SYMBOL OF GRADING AGENCY, MILL NUMBER OR NAME, GRADE OF LUMBER, SPECIES OR SPECIES GROUPING OR COMBINATION DESIGNATION, RULES UNDER WHICH GRADED WHERE APPLICABLE, AND CONDITION OF SEASONING AT TIME OF MANUFACTURE. 2. PLYWOOD: APPROPRIATE GRADE TRADEMARK OF THE APA. INDICATE TYPE, GRADE, CLASS, IDENTIFICATION INDEX AND INSPECTION AND TESTING AGENCY MARK. 3. PRESERVATIVE-TREATED WOOD PRODUCTS: PRESERVATIVE-TREATED LUMBER AND PLYWOOD SHALL BEAR THE QUALITY STANDARD STAMP OF THE APPLICATOR, INDICATING PRESERVATIVE TYPE, EXPOSURE CONDITIONS, YEAR OF TREATMENT, TREATMENT PLANT AND TREATMENT SUPERVISING AGENCY. 4. FIRE-RETARDANT-TREATED WOOD PRODUCTS: FIRE-RETARDANT-TREATED LUMBER AND PLYWOOD SHALL BEAR UL STAMP OR STAMP OF OTHER APPROVED INDEPENDENT INSPECTION AGENCY, INDICATING TREATMENT TYPE OR NAME, FLAME SPREAD AND TREATMENT PLANT. 5. ON COMPONENTS TO BE EXPOSED TO VIEW, GRADE MARKS SHALL BE LOCATED SO AS TO BE CONCEALED IN FINISHED WORK. C. FABRICATOR/INSTALLER QUALIFICATIONS: 1. ARCHITECTURAL WOODWORK SHALL BE FABRICATED AND INSTALLED BY A SINGLE MANUFACTURER. A. FABRICATOR/INSTALLER SHALL HAVE AT LEAST FIVE YEARS SUCCESSFUL EXPERIENCE IN THE FABRICATION, FINISHING AND INSTALLATION OF ARCHITECTURAL WOODWORK OF THE TYPE AND QUANTITY REQUIRED AND, IF REQUESTED BY ARCHITECT, SHALL SUBMIT EVIDENCE OF SUCH EXPERIENCE. B. FABRICATOR/INSTALLER SHALL SUBMIT NEUTRAL PREQUALIFICATION FORM FOUND IN APPENDIX IN AWI QUALITY STANDARDS. 2. FABRICATOR/INSTALLER SHALL BE A MEMBER OF AWI 3. CERTIFICATION SHALL BE EVIDENCED THROUGH APPLICATION OF AWI/QUALITY CERTIFICATION PROGRAM LABELS AND/OR ISSUANCE OF AN AWI LETTER OF LICENSING FOR THE PROJECT. 2.6 ADHESIVES: A. ADHESIVES, GENERAL: ADHESIVES SHALL NOT CONTAIN UREA FORMALDEHYDE. B. VOC LIMITS FOR INSTALLATION ADHESIVES: INSTALLATION ADHESIVES SHALL HAVE A VOC CONTENT LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1113, ARCHITECTURAL COATINGS, RULES IN EFFECT JANUARY 1, 2004. 2.7 FABRICATION: A. GENERAL: 1. QUALITY GRADE FOR ARCHITECTURAL WOODWORK SHALL BE AWI PREMIUM GRADE, EXCEPT THAT OPAQUE-FINISHED WOODWORK SHALL BE CUSTOM GRADE. 2. FABRICATE ARCHITECTURAL WOODWORK IN ACCORD WITH APPROVED SHOP DRAWINGS. 3. SEAL FACES AND EDGES OF MEDIUM DENSITY FIBERBOARD INDICATED TO BE SEALED OR FINISHED. 4. PERFORM VENEER OPERATIONS USING HOT PRESS METHOD USING MOISTURE-RESISTANT, FIRE-RETARDANT ADHESIVES. 5. SHOP-ASSEMBLE FOR DELIVERY TO SITE IN UNITS EASILY HANDLED AND TO PERMIT PASSAGE THROUGH BUILDINGS OPENINGS. ITEMS WHICH CANNOT BE MANUFACTURED IN ONE PIECE SHALL HAVE JOINTS AT LOGICAL BREAKING POINTS AND SHALL BE SO NOTED ON SHOP DRAWINGS. 6. WHEN NECESSARY TO CUT AND FIT ON SITE, PROVIDE MATERIALS WITH AMPLE ALLOWANCE FOR CUTTING. PROVIDE TRIM FOR SCRIBING AND SITE CUTTING. 7. SCRIBE, MITER AND ACCURATELY JOIN MEMBERS. 8. FINISH WORK SHALL BE SMOOTH, FREE FROM ABRASIOIN, TOOL MARKS, OPEN JOINTS OR RAISED GRAIN ON EXPOSED SURFACES. B. CASEWORK: 1. FIT SHELVES, DOORS AND EXPOSED EDGES WITH MATCHING VENEER EDGING. USE ONE PIECE FOR FULL LENGTH ONLY. 2. WHERE COUNTERTOPS CAN NOT BE PROVIDED IN SINGLE LENGTH, JOIN JOIN USING COMPRESSION TYPE FASTENERS. 3. PROVIDE CUTOUTS FOR PLUMBING FIXTURES, INSERTS, APPLIANCES, OUTLET BOXES, FIXTURES AND FITTINGS. VERIFY LOCATIONS OF CUTOUTS FROM ONSITE DIMENSIONS. SEAL CONTACT SURFACES OF CUT EDGES. PART 3 - EXECUTION 3.1 PREPARATION: A. PRIOR TO PRE-INSTALLATION CONFERENCE, EXAMINE SUBSTRATES AND CONDITIONS TO RECEIVE WORK. CHECK THAT FLOORS AND WALL SUBSTRATES ARE LEVEL, PLUMB AND WITHIN TOLERANCES TO RECEIVE WORK SPECIFIED IN THIS SECTION. B. VERIFY MECHANICAL, ELECTRICAL AND BUILDING ITEMS AFFECTING WORK OF THIS SECTION ARE PLACED AND READY TO RECEIVE ARCHITECTURAL WOODWORK. C. DO NOT BEGIN WORK UNTIL UNSATISFACTORY SUBSTRATES OR CONDITIONS HAVE BEEN CORRECTED. D. PRE-INSTALLATION CONFERENCE: 1. PRIOR TO BEGINNING WORK, A PRE-INSTALLATION CONFERENCE WILL BE HELD TO REVIEW WORK TO BE ACCOMPLISHED. 2. CONTRACTOR, FABRICATOR/INSTALLER AND ARCHITECT SHALL BE PRESENT. 3. CONTRACTOR'S SUBMITTALS WILL BE REVIEWED. 4. SUBSTRATES AND CONDITIONS UNDER WHICH WOODWORK SHALL BE INSTALLED WILL BE REVIEWED. 5. CONTRACTOR SHALL NOTIFY ALL PARTIES AT LEAST SEVEN DAYS PRIOR TO TIME OF CONFERENCE. 6. CONTRACTOR SHALL RECORD MINUTES OF MEETING AND DISTRIBUTE TO ALL PARTIES IN ATTENDANCE. 3.2 GENERAL WORKMANSHIP: A. INSTALL WOODWORK IN A MANNER CONSISTENT WITH THE SPECIFIED QUALITY GRADE, PLUMB, LEVEL, TRUE AND STRAIGHT WITHIN 1/8" IN 10'-0". SHIM AS REQUIRED USING CONCEALED SHIMS. B. SECURE TO GROUNDS, STRIPPING AND BLOCKING WITH COUNTERSUNK, CONCEALED FASTENERS AND BLIND NAILING. 1. USE FIXTURE ATTACHMENTS IN CONCEALED LOCATIONS FOR WALL MOUNTED COMPONENTS. 2. SECURE CABINET AND COUNTER BASE TO FLOOR USING ANGLES AND ANCHORAGES. C. SCRIBE AND CUT FOR ACCURATE FIT TO OTHER FINISHED WORK, WITH MAXIMUM GAP OF 1/32". DO NOT USE ADDITION OVERLAY TRIM TO CONCEAL LARGER GAPS. D. USE CONCEALED JOINT FASTENERS TO ALIGN AND SECURE ADJOINING CABINET UNITS AND COUNTERTOPS. E. BEFORE MAKING CUTOUTS, DRILL PILOT HOLES AT CORNERS. F. FINISH WORK SHALL BE SMOOTH, FREE FROM ABRASION, TOOL MARKS, RAISED GRAIN GRADE MARKINGS OR SIMILAR DEFECTS ON EXPOSED SURFACES. G. DISTRIBUTE DEFECTS ALLOWED IN THE QUALITY GRADE SPECIFIED TO THE BEST OVERALL ADVANTAGE WHEN INSTALLING JOB ASSEMBLED WORK. INSTALL WORK IN ACCORD WITH APPROVED SHOP DRAWINGS. H. TOUCH UP MILL FINISHED ITEMS, INCLUDING REFINISHING NECESSITATED BY JOB FITTING OR ATTACHING AND REPAIR OF SCRATCHES AND SIMILAR DAMAGES. TOUCH UP REPAIRS SHALL BE INDISCERNIBLE IN THE FINISHED WORK. 3.3 CLEANING AND PROTECTION: A. PROTECT FINISHED AND PREFINISHED SURFACES FROM WORK OF OTHER TRADES. B. PRIOR TO DATE OF SUBSTANTIAL COMPLETION, EXAMINE WORK FOR DAMAGES. REPAIR OR REPLACE SUCH DAMAGED WORK TO ORIGINAL CONDITION. C. CLEAN WOOD, METAL AND ACCESSORY ITEMS USING A NEUTRAL CLEANER. CHECK AND CORRECT OPERATING MECHANISM FOR PROPER OPERATION. ADJUST AND LUBRICATE HINGES, CATCHES AND OTHER OPERATING HARDWARE. END OF SECTION SECTION 06 6OOO - PLASTIC FABRICATIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND OTHER DIVISION 1 SPECIFICATION SECTION, APPLY TO THIS SECTION. 1.2 SUMMARY: A. THIS SECTION INCLUDES THE PLASTIC FABRICATION AS SHOWN AND SPECIFIED IN THE DESCRIBED SYSTEM: 1. LOW WALL PARTITIONS B. RELATED SECTIONS INCLUDE THE FOLLOWING: 1. SECTION 05 5000 METAL FABRICATIONS 2. SECTION 06 2000 FINISH CARPENTRY AND MILLWORK 3. SECTION 06 6116 SOLID SURFACING FABRICATIONS 1.3 SUBMITTALS: A. GENERAL: SUBMIT THE FOLLOWING IN ACCORDANCE WITH CONDITIONS OF CONTACT AND DIVISION 1 SPECIFICATIONS. B. PRODUCT DATA: SUBMIT MANUFACTURER'S PRODUCT DATA; INCLUDE PRODUCT DESCRIPTION, FABRICATION INFORMATION, AND COMPLIANCE WITH SPECIFIED PERFORMANCE REQUIREMENTS. C. SUBMIT PRODUCT TEST REPORTS FROM A QUALIFIED INDEPENDENT 3RD PARTY TESTING AGENCY INDICATING EACH TYPE AND CLASS OF PANEL SYSTEM COMPLIES WITH THE PROJECT PERFORMANCE REQUIREMENTS, BASED ON COMPREHENSIVE TESTING OF CURRENT PROJECTS. PREVIOUSLY COMPLETED TEST REPORTS WILL BE ACCEPTABLE IF FOR CURRENT MANUFACTURER AND INDICATIVE OF PRODUCTS USED ON THIS PROJECT. 1. TEST REPORTS REQUIRED ARE: A. RATE OF BURNING (ASTM D 635). B. SELF-IGNITION TEMPERATURE (ASTM D 1929). C. DENSITY OF SMOKE (ASTM D 2843). D. FLAME SPREAD AND SMOKE DEVELOPED TESTING (ASTM E 84). E. ROOM CORNER BURN TEST (NFPA 286). F. EXTENT OF BURNING (UL 94). G. IMPACT STRENGTH (ASTM D 3763). H. SAFETY GLAZING IMPACT RESISTANCE (ANSI Z97.1-2004). I. UPITT TEST FOR COMBUSTION PRODUCT TOXICITY. J. DYNAMIC ENVIRONMENTAL TESTING (ASTM STANDARDS D 5116 AND D 6670). D. BUILDING APPROVALS: PLASTIC FABRICATIONS ARE TO HAVE BEEN EVALUATED AND MUST BE REGISTERED WITH AND COMPLY TO REQUIREMENTS OF THE FOLLOWING JURISDICTIONS: 1. NEW YORK DEPARTMENT OF BUILDINGS (PRODUCT MUST HAVE AN MEA [MATERIALS AND EQUIPMENT ACCEPTANCE] NUMBER) FOR USE AS INTERIOR FINISHES. 2. LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY (PRODUCT MUST HAVE A LARR [ LOS ANGELES RESEARCH REPORT] NUMBER) FOR USE AS LIGHT-TRANSMITTING PANELS. E. SHOP DRAWINGS: INCLUDE PLANS, ELEVATIONS, SECTIONS, PANEL DIMENSIONS, DETAILS, AND ATTACHMENTS TO OTHER WORK. D. SAMPLES FOR VERIFICATION: 1. SUBMIT MINIMUM 4-INCH BY 4-INCH SAMPLE FOR EACH TYPE, TEXTURE, PATTERN AND COLOR OF SOLID PLASTIC FABRICATION. H. MOCKUPS: 1. BUILD MOCKUPS TO VERIFY SELECTIONS MADE UNDER SAMPLE SUBMITTALS AND TO DEMONSTRATE AESTHETIC EFFECTS. 2. BUILD MOCKUP OF EACH TYPE OF PLASTIC FABRICATION. 3. APPROVED MOCKUPS MAY BECOME PART OF THE COMPLETED WORK IF UNDISTURBED AT TIME OF SUBSTANTIAL COMPLETION. I. MAINTENANCE DATA: SUBMIT MANUFACTURER'S CARE AND MAINTENANCE DATA, INCLUDING CARE, REPAIR AND CLEANING INSTRUCTIONS. INCLUDE IN PROJECT CLOSEOUT DOCUMENTS. 1.4 QUALITY ASSURANCE: A. MANUFACTURERS QUALIFICATIONS: 1. MATERIALS AND SYSTEMS SHALL BE MANUFACTURED BY A COMPANY CONTINUOUSLY AND REGULARLY EMPLOYED IN THE MANUFACTURE OF SPECIFIED MATERIALS FOR A PERIOD OF AT LEAST FIVE (5) CONSECUTIVE YEARS AND WHICH CAN SHOW EVIDENCE OF THOSE MATERIALS BEING SATISFACTORILY USED ON AT LEAST SIX (6) PROJECTS OF SIMILAR SIZE, SCOPE AND LOCATION. AT LEAST THREE (3) OF THE PROJECTS SHALL HAVE BEEN SUCCESSFUL FOR USE FIVE (5) YEARS OF LONGER. 2. MANUFACTURED PANELS MUST BE PRODUCED FROM A MINIMUM OF 40% POST-INDUSTRIAL RECYCLE CONTENT. THIS RECYCLE CONTENT MUST BE CERTIFIED BY A RECOGNIZED 3RD PARTY CERTIFICATION GROUP, SUCH AS SCIENTIFIC CERTIFICATION SYSTEMS (SCS). 3. MANUFACTURER MUST OFFER A DOCUMENTED RECLAIM PROCESS THAT WILL TAKE BACK, AT THE MANUFACTURERS COST, PANELS THAT ARE AT THEIR END-OF LIFE CYCLE. 1.5 DELIVERY, STORAGE AND HANDLING A. DELIVER PLASTIC FABRICATIONS, SYSTEMS AND SPECIFIED ITEMS IN MANUFACTURER'S STANDARD PROTECTIVE PACKAGING. B. DO NOT DELIVER PLASTIC FABRICATIONS, SYSTEMS, AND COMPONENTS AND ACCESSORIES TO PROJECT SITE UNTIL AREAS ARE READY FOR INSTALLATION. C. STORE MATERIALS IN A FLAT ORIENTATION IN A DRY PLACE THAT IS NOT EXPOSED TO EXTERIOR ELEMENTS. D. HANDLE MATERIALS TO PREVENT DAMAGE TO FINISHED SURFACES. PROVIDE PROTECTIVE COVERINGS TO PREVENT DAMAGE OR STAINING FOLLOWING INSTALLATION FOR DURATION OF PROJECT. E. BEFORE INSTALLING PLASTIC FABRICATIONS, PERMIT THEM TO REACH ROOM TEMPERATURE. 1.6 PROJECT CONDITIONS A. ENVIRONMENTAL LIMITATIONS: DO NOT INSTALL SOLID POLYMER FABRICATIONS UNTIL SPACES ARE ENCLOSED AND WEATHERPROOF, AND AMBIENT TEMPERATURES AND HUMIDITY CONDITIONS ARE MAINTAINED AT THE LEVELS INDICATED FOR PROJECT WHEN OCCUPIED FOR ITS INTENDED USE. 1.7 WARRANTY: A. MANUFACTURER'S SPECIAL WARRANTY ON PLASTIC FABRICATIONS: MANUFACTURER'S STANDARD FORM AGREEING TO REPAIR OR REPLACE UNITS THAT FAIL IN MATERIAL OR WORKMANSHIP WITHIN THE SPECIFIED WARRANTY PERIOD. B. WARRANTY PERIOD: 2 YEAR AFTER THE DATE OF SUBSTANTIAL COMPLETION. C. THE WARRANTY SHALL NOT DEPRIVE THE OWNER OF OTHER RIGHTS OR REMEDIES THE OWNER MAY HAVE UNDER OTHER PROVISIONS OF THE CONTRACT DOCUMENTS, AND IS IN ADDITION TO AND RUNS CONCURRENT WITH OTHER WARRANTIES MADE BY THE CONTRACTOR UNDER THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. PART 2 - PRODUCTS 2.1 MANUFACTURER: A. MANUFACTURER: 3FORM, INC., SALT LAKE CITY, UTAH, USA / TELEPHONE 801-649-2500. 2.2 MATERIALS: A. VARIA™ PRODUCED FROM ECORESING™ SHEET. 1. BASIS OF DESIGN PRODUCT: THE DESIGN OF PLASTIC FABRICATION IS BASED ON VARIA™ PRODUCED WITH ECORESIN™ AS PROVIDED BY 3FORM, INC. PRODUCTS FROM OTHER MANUFACTURERS MUST BE APPROVED BY THE ARCHITECT OR DESIGNER. 2. ENGINEERED POLYESTER RESIN. 3. SHEET SIZE: 4' X 8'. C. RESIN PANEL <RS-1> CHARACTERISTICS: 1. TYPE: STRATA WATER 2. GAUGE: 1/2" 3. FINISH: FRONT- SANDSTONE, BACK - SANDSTONE 4. EDGES: FLAME-POLISHED ON THE 3 VISIBLE SIDES WITH ROUNDED EDGES 5. ORIENTATION: VERTICAL B. RESIN PANEL <RS-2> CHARACTERISTICS: 1. TYPE: TRIBE SEAGRASS+PUREWHITE+TRIBE SEAGRASS 2. GAUGE: 1/2" 3. FINISH: FRONT- SANDSTONE, BACK - SANDSTONE 4. EDGES: FLAME-POLISHED ON THE 3 VISIBLE SIDES WHT ROUNDED EDGES 5. ORIENTATION: VERTICAL D. INTERLAYER MATERIALS: COMPATIBLE WITH POLYESTERS AND BONDING PROCESS TO CREATE A MONOLITHIC SHEET OF MATERIAL WHEN COMPLETE. E. SHEET MINIMUM PERFORMANCE ATTRIBUTES: 1. RATE OF BURNING (ASTM D 635). MATERIAL MUST ATTAIN CC1 RATING FOR A NOMINAL THICKNESS OF 1.5mm (0.060 IN.) AND GREATER. 2. SELF-IGNITION TEMPERATURE GREATER THAN 650 DEGREES F. 3. DENSITY OF SMOKE (ASTM D 2843). MATERIAL MUST HAVE A SMOKE DENSITY LESS THAN 75%. 4. FLAME SPREAD AND SMOKE DEVELOPED TESTING (ASTM E 84). MATERIAL MUST BE ABLE TO MEET A LEVEL OF CLASS A (FLAME SPREAD LESS THAN 25 AND SMOKE LESS THAN 450) AT THICKNESS OF 1". 5. ROOM CORNER BURN TEST (NFPA 286). MATERIAL MUST MEET CLASS A CRITERIA AT 1/4" THICKNESS AS DESCRIBED BY THE 2003 INTERNATIONAL BUILDING CODE. 6. EXTENT OF BURNING (UL 94). MUST SUBMIT UL CARD. 7. IMPACT STRENGTH. MINIMUM IMPACT STRENGTH TEST AS MEASURED BY ASTM D 3763 OF 20 FT. LBS. (FOR DURABILITY, SHIPPING, INSTALLATION, AND USE). 8. SAFETY GLAZING. MATERIAL MUST ATTAIN A CLASS A IMPACT RATING IN ACCORDANCE WITH ANSI Z97.1-2004 AT 1/8" THICKNESS. 9. UPITT TEST FOR COMBUSTION PRODUCT TOXICITY: PRODUCT MUST BE RECORDED AS "NOT MORE TOXIC THAN WOOD". 10. DYNAMIC ENVIRONMENTAL TESTING (ASTM STANDARDS D 5116 AND D 6670). PANELS MUST NOT HAVE DETECTABLE VOC OFF-GASSING AGENTS. 11. PANELS MUST BE PRODUCED FROM A MINIMUM OF 40% POST-INDUSTRIAL RECYCLE CONTENT. THIS RECYCLE CONTENT MUST BE CERTIFIED BY A RECOGNIZED 3RD PARTY CERTIFICATION GROUP, SUCH AS SCIENTIFIC CERTIFICATION SYSTEMS (SCS). 12. BUILDING APPROVALS: PLASTIC FABRICATIONS ARE TO HAVE BEEN EVALUATED AND MUST BE REGISTERED WITH AND COMPLY TO REQUIREMENTS OF THE FOLLOWING JURISDICTIONS: a. LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY (PRODUCT MUST HAVE A LARR [LOS ANGELES RESEARCH REPORT] NUMBER) FOR USE AS LIGHT-TRANSMITTING PANELS. 2.3 FABRICATION: A. GENERAL: FABRICATE PLASTIC FABRICATIONS TO DESIGNS, SIZES AND THICKNESSES INDICATED AND TO COMPLY WITH INDICATED STANDARDS. SIZES, PROFILES AND OTHER CHARACTERISTICS ARE INDICATED ON THE DRAWINGS. B. COMPLY WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS FOR FABRICATION. C. MACHINING: ACCEPTABLE MEANS OF MACHINING ARE LISTED BELOW. ENSURE THAT MATERIAL IS NOT CHIPPED OR WARPED BY MACHINING OPERATIONS. 1. SAWING: SELECT EQUIPMENT AND BLADES SUITABLE FOR TYPE OF CUT REQUIRED. 2. DRILLING: DRILLS SPECIFICALLY DESIGNED FOR USE WITH PLASTIC PRODUCTS. 3. MILLING: CLIMB CUT WHERE POSSIBLE. 4. ROUTING. 5. TAPPING. D. FORMING: FORM PRODUCTS TO SHAPES INDICATED USING THE APPROPRIATE METHOD LISTED BELOW. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. 1. COLD BENDING. 2. HOT BENDING. 3. THERMOFORMING: ACCEPTABLE ONLY ON UNCOATED MATERIAL. 4. DRAPE FORMING. 5. MATCHED MOLD FORMING. 6. MECHANICAL FORMING. E. LAMINATING: LAMINATE TO SUBSTRATES INDICATED USING ADHESIVES AND TECHNIQUES RECOMMENDED BY MANUFACTURER. 2.4 MISCELLANEOUS MATERIALS: A. GENERAL: PROVIDE PRODUCTS OF MATERIAL, SIZE, AND SHAPE REQUIRED FOR APPLICATION INDICATES, AND WITH A PROVEN RECORD OF COMPATIBILITY WITH SURFACES CONTACTED IN INSTALLATION. B. CLEANER: TYPE RECOMMENDED BY MANUFACTURER. C. FASTENERS: USE SCREWS DESIGNED SPECIFICALLY FOR PLASTICS. SELF-THREADING SCREWS ARE ACCEPTABLE FOR PERMANENT INSTALLATIONS. D. BONDING CEMENTS: MAY BE ACHIEVED WITH SOLVENTS OR ADHESIVES, SUITABLE FOR USE WITH PRODUCT AND APPLICATION. PART 3 - EXECUTION 3.1 EXAMINATION: A. EXAMINE SUBSTRATES, AREAS, AND CONDITIONS WHERE INSTALLATION OF PLASTIC FABRICATIONS WILL OCCUR, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH MANUFACTURER'S REQUIREMENTS. VERIFY THAT SUBSTRATES AND CONDITIONS ARE SATISFACTORY FOR INSTALLATION AND COMPLY WITH REQUIREMENTS SPECIFIED. 3.2 INSTALLATION: A. GENERAL: COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR THE INSTALLATION OF PLASTIC FABRICATIONS. B. MANUFACTURER'S SHOP TO FABRICATE ITEMS TO THE GREATEST DEGREE POSSIBLE. C. UTILIZE FASTENERS, ADHESIVES AND BONDING AGENTS RECOMMENDED BY MANUFACTURER FOR TYPE OF INSTALLATION INDICATED. MATERIAL THAT IS CHIPPED, WARPED, HAZED OR DISCOLORED AS A RESULT OF INSTALLATION OR FABRICATION METHODS WILL BE REJECTED. D. INSTALL COMPONENTS PLUMB, LEVEL AND RIGID, SCRIBED TO ADJACENT FINISHES, IN ACCORDANCE WITH APPROVED SHOP DRAWINGS AND PRODUCT DATA. E. FORM FIELD JOINTS MANUFACTURER'S RECOMMENDED PROCEDURES. LOCATE SEAMS IN PANELS SO THAT THEY ARE NOT DIRECTLY IN LINE WITH SEAMS IN SUBSTRATES. 3.3 CLEANING AND PROTECTION: A. PROTECT SURFACES FROM DAMAGE UNTIL DATE OF SUBSTANTIAL COMPLETION. REPAIR WORK OR REPLACE DAMAGED WORK, WHICH CANNOT BE REPAIRED TO ARCHITECT'S SATISFACTION. END OF SECTION SECTION 06 6116 - SOLID SURFACING FABRICATIONS PART 1 - GENERAL 1.1 REFERENCES: A. APPLICABLE STANDARDS: STANDARDS OF THE FOLLOWING, AS REFERENCED HEREIN: 1. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). 2. ASTM INTERNATIONAL (ASTM). 1.2 ACTION SUBMITTALS: A. SHOP DRAWINGS: INDICATE DIMENSIONS, COMPONENT SIZES, FABRICATION DETAILS ATTACHMENT PROVISIONS AND COORDINATION REQUIREMENTS WITH ADJACENT WORK. B. SAMPLES: SUBMIT MINIMUM 6" BY 6" SAMPLES. INDICATE FULL RANGE OF COLOR AND PATTERN VARIATION. APPROVED SAMPLES WILL BE RETAINED AS A STANDARD FOR WORK. C. PRODUCT DATA: INDICATE PRODUCT DESCRIPTION, FABRICATION INFORMATION AND COMPLIANCE WITH SPECIFIED PERFORMANCE REQUIREMENT. 1.3 CLOSEOUT SUBMITTALS: A. MAINTENANCE DATA: SUBMIT MANUFACTURER'S CARE AND MAINTENANCE DATA, INCLUDING REPAIR AND CLEANING INSTRUCTIONS. INCLUDE IN PROJECT CLOSEOUT DOCUMENTS. 1.4 DELIVERY, STORAGE AND HANDLING: A. DELIVER NO COMPONENTS TO PROJECT SITE UNTIL AREAS ARE READY FOR INSTALLATION. STORE INDOORS. B. HANDLE MATERIALS TO PREVENT DAMAGE TO FINISHED SURFACES. PROVIDE PROTECTIVE COVERINGS TO PREVENT PHYSICAL DAMAGE OR STAINING FOLLOWING INSTALLATION FOR DURATION OF PROJECT. 1.5 WARRANTY: A. PROVIDE MANUFACTURER'S WARRANTY AGAINST DEFECTS IN MATERIALS. WARRANTY SHALL PROVIDE FOR REPLACEMENT MATERIAL AND LABOR FOR A PERIOD OF FIVE YEARS, BEGINNING AT DATE OF SUBSTANTIAL COMPLETION. PART 2 - PRODUCTS 2.1 CAST ACRYLIC SURFACING MATERIAL: A. ACCEPTABLE PRODUCTS: 1. BASIS OF DESIGN: E. I. DU PONT DE NEMOURS & CO., INC., CORIAN. 2. INPRO CORPORATION. B. MATERIAL: CAST, 100% ACRYLIC RESIN, SOLID, STRUCTURAL SURFACING MATERIAL. 1. MATERIAL SHALL BE THROUGH-PATTERNED AND HOMOGENEOUS. NO COATED MATERIALS NOR NON-HOMOGENEOUS MATERIALS ALLOWED. 2. HARDNESS: MINIMUM 55 BARCOL HARDNESS, TESTED IN ACCORD WITH ASTM D2583-07, OR INIMUM 90 ROCKWELL HARDNESS, TESTED IN ACCORD WITH ASTM D785-08. 3. TENSILE STRENGTH: MINIMUM 4,200 PSI, TESTED IN ACCORD WITH ASTM D638-10. 4. ABRASION RESISTANCE: MAXIMUM 0.4 GRAMS AT 1,000 CYCLES, TESTED IN ACCORD WITH ASTM C501-84(2009). 5. FIRE-RESISTANCE: FLAME SPREAD AND SMOKE DEVELOPED MEETING ASTM E84-12C, CLASS I RATING. 6. COLOR STABILITY: NO CHANGE IN 200 HOURS, TESTED IN ACCORD WITH NEMA LD3-2005. 7. WATER ABSORPTION: MAXIMUM 0.04% FOR 3/4" THICKNESS AND 0.06% FOR 1/2" THICKNESS, TESTED IN ACCORD WITH ASTM D570-98(2010). 8. FUNGAL RESISTANCE: NO ATTACK WHEN TESTED IN ACCORD WITH ASTM G21-09. 9. BACTERIAL RESISTANCE: NO ATTACK WHEN TESTED IN ACCORD WITH ASTM G22-76(1996)(WITHDRAWN 2002). 10. IMPACT RESISTANCE: NO FRACTURE WHEN TESTED IN ACCORD WITH NEMA LD3-2005; SECTION 3.3, 144" DROP FOR 1/2" THICKNESS AND 204" DROP FOR 3/4" THICKNESS. 11. SUPERFICIAL DAMAGE TO A DEPTH OF 0.10" SHALL BE REPAIRABLE BY SANDING AND POLISHING. 12. SURFACES SHALL BE UN AFFECTED BY CLASS I REAGENTS AND SHALL BE REPAIRABLE AFTER EXPOSURE TO CLASS II REAGENTS. CLASS I AND II REAGENTS SHALL BE AS IDENTIFIED IN BASIS OF DESIGN MANUFACTURER'S PRODUCT DATA. 13. SURFACES AT DRUG COMPOUNDING COUNTER IN THE PHARMACY ARE TO BE CHEMICAL RESISTANT. C. FINISH: MATTE (GLOSS RATING OF 5-20). D. COLOR: AS SELECTED BY ARCHITECT. E. THICKNESS: AS INDICATED IN DRAWINGS. 2.2 ACCESSORY PRODUCTS: A. JOINT ADHESIVE: MANUFACTURER'S STANDARD, TWO-PART ADHESIVE KIT TO CREATE INCONSPICUOUS, NON-POROUS JOINTS, WITH A CHEMICAL BOND. B. SEALANT: MANUFACTURER'S STANDARD MILDEW-RESISTANT, USDA/UL RECOGNIZED SILICONE SEALANT IN COLOR MATCHING SURFACING OR CLEAR FORMULATIONS. C. ADHESIVES AND SEALANTS VOC CONTENT: ADHESIVE AND SEALANTS SHALL HAVE A VOC CONTENT LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1168, ADHESIVES AND SEALANTS, AMENDED JANUARY 7, 2005. 2.3 FABRICATION: A. FACTORY-FABRICATE COMPONENTS TO GREATEST EXTENT PRACTICABLE, TO SIZES AND SHAPES INDICATED, IN ACCORD WITH APPROVED SHOP DRAWINGS. B. FORM JOINTS BETWEEN COMPONENTS USING MANUFACTURER'S STANDARD JOINT ADHESIVE; WITHOUT CONSPICUOUS JOINTS AND WITHOUT VOIDS. ATTACH A 2" WIDE REINFORCING STRIP OF SOLID SURFACING UNDER EACH JOINT. C. PROVIDE FACTORY CUTOUTS FOR PLUMBING FITTINGS AND ACCESSORIES AS INDICATED. D. ROUT AND FINISH COMPONENT EDGES TO A SMOOTH, UNIFORM FINISH. ROUT CUTOUTS AND SAND EDGES SMOOTH. MACHINE RADII AND CONTOURS TO TEMPLATE. REPAIR OR REJECT DEFECTIVE AND INACCURATE WORK. E. EDGE TREATMENT FOR TOPS: AS INDICATED ON DRAWINGS. 2.4 SOURCE QUALITY CONTROL: A. ALLOWABLE TOLERANCES: 1. VARIATION IN COMPONENT SIZE: + -1/8". 2. LOCATION OF OPENINGS: + -1/8" FROM INDICATED LOCATION. PART 3 - EXECUTION 3.1 INSTALLATION: A. INSTALL COMPONENTS PLUMB, LEVEL AND RIGID, SCRIBED TO ADJACENT FINISHES, IN ACCORD WITH APPROVED SHOP DRAWINGS AND PRODUCT DATA. B. FORM FIELD JOINTS USING SPECIFIED ADHESIVE, WITH JOINTS INCONSPICUOUS IN FINISHED WORK. C. PROVIDE BACK AND END SPLASHES AS INDICATED. ADHERE TO COUNTERTOPS USING SPECIFIED COLOR-MATCHED SILICONE ADHESIVE. D. KEEP COMPONENTS CLEAN DURING INSTALLATION. REMOVE ADHESIVES, SEALANTS AND OTHER STAINS. KEEP CLEAN UNTIL DATE OF SUBSTANTIAL COMPLETION. REPLACE STAINED COMPONENTS. E. MAKE PLUMBING CONNECTIONS TO SINKS IN ACCORD WITH DIVISION 22, PLUMBING. 3.2 PROTECTION: A. PROTECT SURFACES FROM DAMAGE UNTIL DATE OF SUBSTANTIAL COMPLETION. REPAIR OR REPLACE DAMAGED WORK WHICH CANNOT BE REPAIRED. 1.4 DELIVERY, STORAGE AND HANDLING: A. DELIVER NO WOODWORK TO PROJECT SITE UNTIL AREAS ARE READY FOR WOODWORK INSTALLATION. B. IMMEDIATELY UPON DELIVERY TO JOB SITE, PLACE WOODWORK INDOORS, PROTECTED FROM WEATHER. C. STORE WOODWORK A MINIMUM OF 6" ABOVE FLOOR ON BLOCKING AND COVER WITH WATERPROOF COVERING. PROVIDE FOR AIR CIRCULATION AND VENTILATION. STORE IN DRY, CONDITIONED SPACE. D. WRAP PREFINISHED WOODWORK IN PROTECTIVE COVERING FOR SHIPPING AND STORAGE. PROTECT FROM SUNLIGHT EXPOSURE. 1.5 PROJECT CONDITIONS: A. FIELD MEASUREMENTS: TAKE FIELD MEASUREMENTS TO ASCERTAIN EXACT WOODWORK SIZES. INDICATE EXACT DIMENSIONS ON SHOP DRAWINGS. B. INSTALL NO INTERIOR WOODWORK UNTIL SPACES ARE ENCLOSED, DRY AND CONDITIONED. MAINTAIN TEMPERATURE BETWEEN 55 DEGREES F. AND 80 DEGREES F. FOR 72 HOURS BEFORE BEGINNING INSTALLATION AND AFTERWARDS UNTIL DATE OF SUBSTANTIAL COMPLETION. C. MAINTAIN INTERIOR RELATIVE HUMIDITY AT THE SITE BETWEEN 25% AND 55% BEFORE, DURING, AND AFTER INSTALLATION. PART 2 - PRODUCTS 2.1 BASIC MATERIALS: A. GENERAL: PROVIDE MATERIALS THAT COMPLY WITH REQUIREMENTS OF AWI'S QUALITY STANDARD FOR EACH TYPE OF WOODWORK AND QUALITY GRADE SPECIFIED, UNLESS OTHERWISE INDICATED. B. WOOD PRODUCTS: COMPLY WITH THE FOLLOWING: 1. RECYCLED CONTENT OF MEDIUM-DENSITY FIBERBOARD AND PARTICLEBOARD: POSTCONSUMER RECYCLED CONTENT PLUS ONE-HALF OF PRECONSUMER RECYCLED CONTENT NOT LESS THAN 30 PERCENT. 2. LOW-EMITTING MATERIALS: A. HARDBOARD: AHA A135.4; 1/4" THICKNESS. B. MEDIUM-DENSITY FIBERBOARD: MEETING ANSI A208.2, GRADE MD; CLASS "C" FIRE HAZARD CLASSIFICATION FOR 3/4" THICKNESS, MADE WITH BINDER CONTAINING NO UREA FORMALDEHYDE. C. PARTICLEBOARD: MEETING ANSI A208.1, GRADE M-2 EXTERIOR GLUE; MAT-FORMED, MANUFACTURED OF LONG FIBERED CUTTINGS, WEIGHING MINIMUM OF 40 LBS./CU. FT.; FIRE-RETARDANT-TREATED (FR), MEETING NFPA 101; MOISTURE-RESISTANT (MR); FILLED ON FACES TO BE PAINTED, MADE WITH BINDER CONTAINING NO UREA FORMALDEHYDE. D. PLYWOOD: 1) VENEER-FACED PRODUCTS (HARDWOOD PLYWOOD): HPVA HP-1 AND AWPA P17-02, MADE WITH ADHESIVE CONTAINING NO UREA FORMALDEHYDE. 2) SOFTWOOD PLYWOOD: DOC PS 1, MEDIUM DENSITY OVERLAY. C. PLASTIC LAMINATES: 1. ACCEPTABLE PRODUCTS: A. BASIS OF DESIGN: ARBORITE B. BASIS OF DESIGN: WILSONART INTERNATIONAL, INC., WILSONART 2. CONFORMING TO NEMA STANDARD LD3-2005, AS FOLLOWS: A. HORIZONTAL APPLICATIONS: GRADE HGS. B. VERTICAL APPLICATIONS: GRADE VGS. C. CABINET-LINER: GRADE CL-20. D. BACKING SHEET: GRADE BKH, UNDECORATED PLASTIC LAMINATE. E. POST-FORMING APPLICATIONS: GRADE VGP. F. CHEMICAL RESISTANT APPLICATIONS: GRADE VGP. G. SOLID COLOR APPLICATIONS: GRADE HGS. H. PROVIDE ABUSE-RESISTANT LAMINATES FOR EXPOSED PORTIONS OF THE WORK. 3. COLORS, TEXTURES AND PATTERNS: AS INDICATED IN FINISH SCHEDULE IN DRAWINGS. 2.2 ARCHITECTURAL CABINETS: A. ARCHITECTURAL CABINETS SHALL COMPLY WITH AWI STANDARDS, SECTION 400 B. PLASTIC LAMINATE CLAD CABINETS: 1. AWI QUALITY GRADE: CUSTOM. 2. PANEL CORE: PARTICLEBOARD OR HARDWOOD PLYWOOD. 3. FINISH ON EXPOSED SURFACES: PLASTIC LAMINATE AS SPECIFIED HEREIN. 4. FINISH ON SEMI-EXPOSED SURFACES: MELAMINE SPECIFIED HEREIN. 5. COMPONENT EDGES: PLASTIC LAMINATE FACED. 6. CABINET CONSTRUCTION: FLUSH OVERLAY. C. COUNTER TOPS: 1. PLASTIC LAMINATE AND AS SPECIFIED HEREIN. 2. CORIAN AS SPECIFIED IN SOLID SURFACING FABRICATIONS SECTION. 2.3 MISCELLANEOUS WOODWORK: A. COMPLY WITH AWI STANDARDS AS FOLLOWS: 1. SHELVING: SECTION 6, CUSTOM GRADE. 2. BACKSPLASH: SECTION 6, CUSTOM GRADE. 2.4 TREATED WOOD PRODUCTS: A. PRESSURE-PRESERVATIVE-TREATED WOOD: 1. TREATMENT TYPE: WATER-BORNE PRESERVATIVE REGISTERED WITH EPA. 2. AWPA STANDARD: A. LUMBER, TIMBER AND PLYWOOD SHALL CONFORM TO APPLICABLE REQUIREMENTS OF AWPA STANDARD U1-07 AND T1-07 FOR SPECIES, PRODUCT AND END USE. B. HANDLING AND CARE OF PRESSURE TREATED WOOD PRODUCTS SHALL CONFORM TO AWPA STANDARD M4-06. C. PRESERVATIVES SHALL CONFORM TO AWPA P5-07 3. PRESERVATIVE RETENTION: AS REQUIRED BY TREATMENT TYPE IN ACCORD WITH AWPA STANDARDS FOR BELOW- OR ABOVE-GROUND USE. 4. SEASONING; RE-DRY AFTER TREATMENT TO 19% MAXIMUM MOISTURE CONTENT. 5. USE: A. WOOD PRODUCTS IN CONTACT WITH CONCRETE SLABS-ON-GRADE OR FOUNDATIONS. B. NAILERS OR BLOCKING CAST OR BUILT INTO CONCRETE. C. WOOD PRODUCTS IN CONTACT WITH EXTERIOR WALLS. B. INTERIOR FIRE-RETARDANT-TREATED WOOD: 1. ACCEPTABLE PRODUCT; SUBJECT TO COMPLIANCE WITH SPECIFIED REQUIREMENTS: A. VIANCE, LLC, D-BLAZE. B. HICKSON CORPORATION, DRICON. C. HOOVER TREATED WOOD PRODUCTS, PYRO-GUARD. 2. DESCRIPTION: PRESSURE-IMPREGNATED WITH A CHEMICAL RETARDANT TESTED AND LISTED BY UNDERWRITERS LABORATORIES, INC., (UL). WHEN TESTED IN ACCORD WITH ASTM E84-10B TREATED PRODUCTS SHALL HAVE A FLAME SPREAD OF 25 OR LESS AND SHOW NO EVIDENCE OF SIGNIFICANT PROGRESSIVE COMBUSTION WHEN THE TEST IS CONTINUED FOR AN ADDITIONAL TWENTY MINUTE PERIOD. IN ADDITION, FLAME FRONT SHALL NOT PROGRESS MORE THAN 10'-6" BEYOND CENTERLINE OF BURNERS AT ANY TIME DURING TEST. 3. SURFACE BURNING CHARACTERISTICS: F.R.-S RATING IN ACCORD WITH UNDERWRITERS LABORATORIES, INC. (UL). 4. AWPA STANDARD: AWPA U1-07, T1-07 AND P17-02 5. SEASONING; KILN-DRIED AFTER TREATMENT TO THE FOLLOWING MAXIMUM MOISTURE CONTENT: A. LUMBER: 19% B. PLYWOOD: 15% 6. HYGROSCOPICITY: MAXIMUM 28% EQUILIBRIUM MOISTURE CONTENT WHEN TESTED IN ACCORD WITH ASTM D3201-08A AT 92% RELATIVE HUMIDITY. 7. USE: AS REQUIRED BY CODES. 2.5 HARDWARE: A. DOORS: 1. HINGES: BLUM No. 70T555, 120 DEGREE "CLIP" HINGE. 2. PULLS: BECKER #BP225-04, 96 MM WITH ALUMINUM FINISH. 3. LOCKS: 5-PIN TUMBLER TYPE BY NATIONAL LOCK WITH MASTER KEY, OR EQUAL B. DRAWERS: 1. PULLS: BECKER #BP225-04, 96mm WITH ALUMINUM FINISH. 2. DRAWER AND FILE DRAWER SLIDES: KV MODEL #8400, 100 LB. CAPACITY, OR EQUAL. C. SHELVING: 1. ADJUSTABLE SHELVING: PRE-BORED 5mm DIAMETER AT 32mm ON CENTER. 2. SHELF CLIP: AMCO #11 EARTHQUAKE SAFETY WITH TWO 5mm PIN AT 32mm ON CENTER. D. GROMMETS: D. MOCKETT & CO., INC., SERIES 7G, BLACK COLOR AS SELECTED BY ARCHITECT; LOCATIONS AS INDICATED ON THE DRAWINGS. E. MAGNETIC CATCHES: 1. ACCEPTABLE MANUFACTURERS: A. BASIS OF DESIGN: STANLEY WORKS #SP41. B. EPCO, INC. C. SUGATSUNE AMERICA, INC. 2. FINISH: FINISH SELECTED BY ARCHITECT. F. RECESSED SHELF STANDARDS AND SUPPORTS: 1. ACCEPTABLE MANUFACTURERS: A. BASIS OF DESIGN: KNAPE AND VOGT MFG. CO., #255 STANDARD WITH #256 SUPPORT. B. STANLEY WORKS. C. JOHNSON HARDWARE, INC. D. SUGATSUNE AMERICA, INC. E. HAFELE AMERICA CO. 2. TYPE: STEEL. 3. FINISH: FINISH AS SELECTED BY ARCHITECT. G. UNDERCARRIAGE DRAWER SLIDES: 1. ACCEPTABLE MANUFACTURERS: A. BASIS OF DESIGN: KNAPE AND VOGT MFG. CO., #1500 B. ACCURIDE. C. GRANT HARDWARE CO. 2. CAPACITY: 50 LB. H. WIRE MANAGEMENT GROMMET: 1. ACCEPTABLE PRODUCTS: A. BASIS OF DESIGN; DOUG MOCKETT & CO., AS INDICATED ON DRAWINGS. B. OUTWATER PLASTICS, INC., #31-2". C. SUGATSUNE AMERICA, INC., #V60. D. HAFELE AMERICA, INC., #429.93.313. 2. PROVIDE SET INCLUDING GROMMET, GROMMET CAP AND SLOT COVER; COLOR AS SELECTED BY ARCHITECT FROM MANUFACTURER'S STANDARD SELECTION. I. FASTENERS: PROVIDE BOLTS, NAILS, SCREWS, TOGGLE BOLTS AND SIMILAR FASTENERS AS INDICATED OR REQUIRED TO ATTACH AND SECURE WORK. 1. FASTENERS FOR TRIM SHALL BE FINISHING NAILS FOR ATTACHMENT TO WOOD FRAMING, TRIM-HEAD SCREWS FOR ATTACHMENT TO METAL FRAMING. 2. MATERIAL AND FINISH FOR NON-PRESSURE TREATED AND FIRE-RETARDANT- TREATED COMPONENTS SHALL BE G90 HOT DIP GALVANIZED STEEL OR TYPE 304 STAINLESS STEEL, EXCEPT NAILS SHALL BE HOT DIP GALVANIZED. 3. MATERIAL AND FINISH FOR PRESSURE-TREATED COMPONENTS SHALL BE G185 HOT-DIP GALVANIZED STEEL OR TYPE 316L STAINLESS STEEL. DIVISION 7 - THERMAL AND MOISTURE PROTECTION SECTION 07 8400 - FIRESTOPPING PART 1 - GENERAL 1.1 SUMMARY: A. RELATED WORK: 1. METAL FABRICATIONS. 2. ROUGH CARPENTRY. 3. JOINT SEALANTS. 4. GYPSUM BOARD. 5. PLUMBING. 6. ELECTRICAL. 1.2 SYSTEM PERFORMANCE REQUIREMENTS: A. FIRESTOPPING SYSTEMS SHALL PROVIDE RESISTANCE TO SPREAD OF FIRE, AND PASSAGE OF SMOKE AND OTHER GASES ACCORDING TO REQUIREMENTS INDICATED, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1. FIRESTOP PENETRATIONS PASSING THROUGH FIRE RESISTANCE RATED WALL AND FLOOR ASSEMBLIES AND OTHER LOCATIONS AS INDICATED ON DRAWINGS. 2. PENETRATION FIRESTOPPING SYSTEMS SHALL HAVE BEEN TESTED AND APPROVED BY A THIRD PARTY TESTING AGENCY. 3. THROUGH-PENETRATION FIRESTOP SYSTEMS AND DEVICES SHALL RESIST SPREAD OF FIRE, AND PASSAGE OF SMOKE AND OTHER GASES ACCORDING TO REQUIREMENTS INDICATED, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: A. F - RATING SHALL EQUAL OR EXCEED THE RATING OF THE FIRE-RESISTIVE CONSTRUCTION ASSEMBLY THROUGH WHICH THE PENETRATION IS MADE, AS DETERMINED BY ASTM E814-11A, BUT SHALL NOT BE NOT LESS THAN 1-HOUR. B. T- RATING, IN ADDITION TO F-RATING, AT PENETRATIONS LOCATED OUTSIDE OF A WALL CAVITY, SHALL EQUAL FIRE-RESISTIVE RATING OF FLOOR CONSTRUCTION, AS DETERMINED BY ASTM E814-11A, BUT SHALL BE NOT LESS THAN 1-HOUR. C. L - RATING: IN ADDITION TO F AND T RATINGS, FIRESTOPPING SHALL HAVE AN L - RATING, AS DETERMINED BY UL 1479, WHERE INDICATED BY CODE. 4. PERIMETER FIRE CONTAINMENT SYSTEMS (EXTERIOR CURTAINWALL/FLOOR INTERSECTION): INTERIOR PERIMETER JOINT SYSTEMS WITH FIRE-RESISTANCE RATINGS INDICATED, AS DETERMINED BY ASTM E2307-10, BUT NOT LESS THAN FIRE-RESISTANCE RATING OF THE FLOOR CONSTRUCTION. 5. FIRE-RESISTIVE JOINTS SHALL HAVE FIRE-RESISTANCE RATINGS INDICATED, AS DETERMINED BY UL 2079, BUT NOT LESS THAN FIRE-RESISTANCE RATING OF CONSTRUCTION IN WHICH THE JOINT OCCURS. 6. FIRESTOP SYSTEMS USING CEMENTITIOUS FILL MATERIALS SHALL NOT BE PERMITTED. 7. SYSTEMS SHALL BE FREE OF ASBESTOS AND VOLATILE ORGANIC COMPOUNDS (VOCs). 8. WHERE THERE IS NO SPECIFIC THIRD PARTY TESTED AND CLASSIFIED FIRESTOP SYSTEM AVAILABLE FOR A PARTICULAR FIRESTOP CONFIGURATIONS, OBTAIN FROM FIRESTOP MANUFACTURER, AN ENGINEERING JUDGEMENT (EJ) OR EQUIVALENT FIRE RESISTANCE RATED ASSEMBLY (EFFRA). 9. SYSTEMS USED WITHIN OR ADJACENT TO OCCUPIED SPACES SHALL BE FREE OF VOLATILE SOLVENTS, NOXIOUS FUMES AND STRONG ODORS. 10. FIRESTOPPING USED FOR THIS PROJECT SHALL BE FMR APPROVED AS LISTED IN THE CURRENT EDITION OF THE FMR BUILDING MATERIAL APPROVAL GUIDE. 1.3 ACTION SUBMITTALS: A. SHOP DRAWINGS: SUBMIT DETAILED DRAWINGS OF EACH TYPE AND SIZE PENETRATION THROUGH FIRE-RATED CONSTRUCTION, INDICATING MATERIALS, DIMENSIONS, ASSEMBLY CONSTRUCTION AND RATING. INDICATE THROUGH-PENETRATION FIRESTOP SYSTEM DESIGN LISTINGS, INCLUDING ILLUSTRATIONS FROM A QUALIFIED TESTING AND INSPECTION AGENCY FOR EACH TYPE PENETRATION. B. PRODUCT DATA: SUBMIT PRODUCT DATA AND INSTALLATION INSTRUCTIONS FOR EACH TYPE OF INSTALLATION. INCLUDE INSTALLATION DETAILS AND TEST REPORTS INDICATING THAT FIRESTOPPING MATERIALS, SYSTEMS AND DEVICES MEET SPECIFIED REQUIREMENTS AND DESIGN CRITERIA. INDICATE CLASSIFICATION MARKING OF QUALIFIED TESTING AND INSPECTION AGENCY. 1.4 INFORMATIONAL SUBMITTALS: A. CERTIFICATIONS: 1. SUBMIT WRITTEN CERTIFICATION THAT FIRESTOP MATERIALS ARE ASBESTOS FREE AND THAT MATERIALS COMPLY WITH LOCAL REGULATIONS. 2. SUBMIT WRITTEN CERTIFICATION THAT FIRESTOP MATERIALS COMPLY WITH LOCAL REGULATIONS CONTROLLING USE OF VOLATILE ORGANIC COMPOUNDS (VOCs) AND ARE NON-TOXIC TO BUILDING OCCUPANTS. 1.5 QUALITY ASSURANCE: A. APPLICABLE STANDARDS; STANDARDS OF THE FOLLOWING, AS REFERENCED HEREIN: 1. ASTM INTERNATIONAL (ASTM). 2. FACTORY MUTUAL RESEARCH (FMR) 3. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA). 4. UNDERWRITERS LABORATORIES, INC. (UL). R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:23:21 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) G0-02 SPECIFICATIONS CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 B. FIRE-TEST-RESPONSE CHARACTERISTICS: PROVIDE FIRESTOPPING SYSTEM DESIGN LISTING BY A TESTING AND INSPECTION AGENCY IN ACCORD WITH THE SPECIFIED UL STANDARDS. C. ACCEPTABLE INSTALLER SHALL BE: 1. INSTALLER QUALIFICATIONS: A FIRM THAT HAS BEEN APPROVED BY FM GLOBAL ACCORDING TO FM GLOBAL 4991, "APPROVAL OF FIRESTOP CONTRACTOR," OR BEEN EVALUATED BY UL AND FOUND TO COMPLY WITH UL's "QUALIFIED FIRESTOP CONTRACTOR PROGRAM REQUIREMENTS." 2. LICENSED BY STATE OR LOCAL AUTHORITY, WHERE APPLICABLE. 3. SUCCESSFULLY COMPLETED NOT LESS THAN 5 COMPARABLE SCALE PROJECTS. D. SINGLE SOURCE RESPONSIBILITY: OBTAIN FIRESTOP SYSTEMS FOR EACH KIND OF PENETRATION AND CONSTRUCTION CONDITION INDICATED FROM A SINGLE PRIMARY FIRESTOP SYSTEMS MANUFACTURER. 1. MATERIALS FROM DIFFERENT MANUFACTURER THAN ALLOWED BY TESTED AND LISTED SYSTEM SHALL NOT BE INTERMIXED IN THE SAME FIRESTOP SYSTEM OR OPENING. 2. INSTALL TESTED AND LISTED FIRESTOP SYSTEMS BEFORE INSTALLING AN ENGINEERING JUDGEMENT OR EQUIVALENT FIRE RESISTANCE RATED ASSEMBLY (EFFRA). 1.6 DELIVERY STORAGE AND HANDLING: A. DELIVER FIRESTOPPING MATERIALS IN ORIGINAL, UNOPENED CONTAINERS OR PACKAGES WITH INTACT AND LEGIBLE MANUFACTURER'S LABELS IDENTIFYING PRODUCT AND MANUFACTURER. B. STORE AND HANDLE FIRESTOPPING MATERIALS IN ACCORD WITH MANUFACTURER'S PRODUCT DATA. 1.7 JOB CONDITIONS: A. COORDINATE FIRESTOPPING INSTALLATION WITH OTHER WORK REQUIRING PENETRATIONS THROUGH FIRE-RESISTIVE CONSTRUCTION. INSTALL PENETRATING ELEMENTS PRIOR TO INSTALLATION OF FIRESTOPPING SYSTEMS OR DEVICES. B. SECURE INSPECTION AND APPROVAL OF FIRESTOPPING WORK BY BUILDING OFFICIALS PRIOR TO CONCEALMENT. C. SUPPORT PENETRATING ELEMENTS INDEPENDENTLY OF FIRESTOPPING SYSTEMS OR DEVICES. D. DO NOT COVER UP FIRESTOPPING INSTALLATIONS UNTIL OWNER'S INSPECTION AGENCY OR AUTHORITIES HAVING JURISDICTION HAVE EXAMINED EACH INSTALLATION. PART 2 - PRODUCTS 2.1 MATERIALS, GENERAL: A. VOC CONTENT: PENETRATION FIRESTOPPING SEALANTS AND SEALANT PRIMERS SHALL HAVE A VOC CONTENT LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1113, ARCHITECTURAL COATINGS, RULES IN EFFECT JANUARY 1, 2004. 2.2 THROUGH-PENETRATION FIRESTOP SYSTEMS: A. ACCEPTABLE MANUFACTURERS; SUBJECT TO COMPLIANCE WITH SPECIFIED REQUIREMENTS: 1. GRACE CONSTRUCTION PRODUCT. 2. HILTI USA. 3. 3M FIRE PROTECTION PRODUCTS. 4. NELSON FIRESTOP PRODUCTS. 5. RECTOR SEAL CORP. 6. SPECIFIED TECHNOLOGIES, INC. (STI). 7. TREMCO, INC. B. SYSTEM DESCRIPTION: FIELD-CONSTRUCTED FIRESTOPPING FOR PENETRATIONS THROUGH WALLS AND FLOORS COMPOSED OF SPECIFIED MATERIALS AND ACCESSORIES ASSEMBLED IN ACCORD WITH THROUGH-PENETRATION FIRESTOPPING SYSTEM NUMBERS, LISTED IN UL BUILDING MATERIALS DIRECTORY, CURRENT EDITION, AND TESTED IN ACCORD WITH ASTM E814-11A. C. MATERIALS: UL CLASSIFIED FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS. 1. FIRESTOP SEALANT: SINGLE-COMPONENT, ELASTOMERIC SILICONE OR ENDOTHERMIC LATEX SEALANT COMPOUND; SELF-ADHERING, FLEXIBLE AND WATERTIGHT; NON SAG AND SELF-LEVELING TYPES AS REQUIRED. 2. FIRESTOP FOAM: TWO-PART, ROOM TEMPERATURE VULCANIZING, SILICONE ELASTOMER, NON-COMBUSTIBLE FOAM VOID SEAL. 3. INTUMESCENT SEALANTS AND PUTTIES: SINGLE-COMPONENT, SYNTHETIC, ORGANIC/INORGANIC INTUMESCENT ELASTOMERS. 4. INTUMESCENT WRAP STRIPS: ONE-PART, ORGANIC/INORGANIC, INTUMESCENT ELASTOMERIC SHEET; ALUMINUM FOIL-FACED ONE SIDE. 5. INTUMESCENT COMPOSITE SHEETS: COMPOSITE SHEETS COMPOSED OF ORGANIC/INORGANIC INTUMESCENT ELASTOMERIC CORE BONDED ON ONE SIDE TO 28 GA. GALVANIZED STEEL SHEET AND OTHER SIDE REINFORCED WITH STEEL WIRE MESH, COVERED WITH ALUMINUM FOIL. 6. MINERAL WOOL OR CERAMIC FIBER SAFING: NON-COMBUSTIBLE FIBER TESTED IN ACCORD WITH ASTM E136-12, WITH MELTING POINT IN EXCESS OF 2000 DEGREES F.; FLAME SPREAD OF 15 MAXIMUM AND 0 SMOKE DEVELOPMENT WHEN TESTED IN ACCORD WITH ASTM E84-12C. THICKNESS AND DENSITY SHALL BE AS REQUIRED BY THROUGH-PENETRATION FIRESTOP SYSTEM DESIGNS. D. ACCESSORIES: 1. PRIMERS, ADHESIVES AND BACKER RODS: AS REQUIRED BY MANUFACTURER'S PRODUCT DATA AND SYSTEM DESIGNS. 2. FORMING, DAMMING AND PACKING MATERIALS: TYPES AS INDICATED IN THROUGH-PENETRATION FIRESTOP SYSTEMS. 3. RESTRICTING COLLARS: MANUFACTURER'S STANDARD DESIGN AS REQUIRED FOR FIRESTOP SYSTEMS. 4. FASTENERS, ANCHOR CLIPS, SLEEVES, CLAMPS, SPACERS, TIES, COVER PLATES AND MISCELLANEOUS ACCESSORIES: PROVIDE AS REQUIRED BY MANUFACTURER'S PRODUCT DATA AND IN ACCORD WITH THROUGH- PENETRATION FIRESTOP SYSTEM DESIGNS. 2.3 THROUGH-PENETRATION FIRESTOP DEVICES: A. ACCEPTABLE MANUFACTURERS; SUBJECT TO COMPLIANCE WITH SPECIFIED REQUIREMENTS: 1. GRACE CONSTRUCTION PRODUCTS. 2. HILTI USA. 3. ISOLATEK INTERNATIONAL, INC. 4. NELSON FIRESTOP PRODUCTS. 5. PROSET SYSTEMS, INC. 6. SPECIFIED TECHNOLOGIES, INC. (STI). 7. TREMCO, INC. B. TYPES: FACTORY-ASSEMBLED, SELF-CONTAINED FIRESTOPPING DEVICES FOR PENETRATIONS THROUGH WALLS AND FLOORS; UL CLASSIFIED FOR THROUGH- PENETRATION FIRESTOP DEVICES AS LISTED IN UL BUILDING MATERIALS DIRECTORY, CURRENT EDITION, AND TESTED IN ACCORD WITH ASTM E-814-11A. C. ACCESSORIES: PROVIDE SEALANTS, ADHESIVES, FASTENERS, SLEEVES, CLAMPS, SPACERS, ANCHOR CLIPS, TIES AND ACCESSORIES IN ACCORD WITH MANUFACTURER'S PRODUCT DATA AND AS REQUIRED FOR COMPLETE INSTALLATION. 2.4 FIRESTOP SEALANTS: A. ACCEPTABLE PRODUCTS; SUBJECT TO COMPLIANCE WITH SPECIFIED REQUIREMENTS: 1. GRACE CONSTRUCTION PRODUCTS, FLAMESAFE SILICONE SEALANT. 2. HILTI USA, CP 601S FIRESTOP SEALANT. 3. NELSON FIRESTOP PRODUCTS, CLK. 4. 3M FIRE PROTECTION PRODUCTS, FIRE BARRIER SILICONE SEALANT 2000 N/S 5. RECTOR SEAL CORP., METACAULK 835+. 6. SPECIFIED TECHNOLOGIES, INC. (STI), SPECSEAL PEN 300 SILICONE JOINT SEALANT. 7. TREMCO, INC., FYRE-SIL. B. CHARACTERISTICS: SINGLE-COMPONENT, SELF-ADHERING, FLEXIBLE, WATERTIGHT, ELASTOMERIC SILICONE SEALANT COMPOUND; UL CLASSIFIED. PROVIDE SELF-LEVELING TYPE FOR HORIZONTAL APPLICATIONS, NON-SAG TYPE FOR ALL OTHER APPLICATIONS. 2.5 SAFING: A. ACCEPTABLE PRODUCTS; SUBJECT TO COMPLIANCE WITH SPECIFIED REQUIREMENTS: 1. GENERAL INSULATION COMPANY, FBX SAFING INSULATION. 2. THERMAL CERAMICS, CERABLANKET F.S. 3. THERMAFIBER INC., THERMAFIBER SAFING INSULATION. B. CHARACTERISTICS: 1. MATERIAL: SEMI-RIGID MINERAL FIBER INSULATION, MEETING ASTM C665-12, TYPE 1. 2. DENSITY: 4.0 PCF. 3. THICKNESS: AS INDICATED. 4. FACING: UNFACED OR REINFORCED FOIL FACING, BASED ON UL DESIGN SELECTED. 5. FIRE RESISTANCE PROPERTIES: A. MELTING POINT: MINIMUM OF 2000 DEGREES F. WHEN TESTED IN ACCORD WITH ASTM C24-09. B. NON-COMBUSTIBLE: AS DEFINED BY ASTM E136-12 AND NFPA. C. FIRE HAZARD CHARACTERISTICS: MAXIMUM FLAME SPREAD OF 15 AND SMOKE DEVELOPMENT OF 5 WHEN TESTED IN ACCORD WITH ASTM E84-12C (UNFACED). 6. FIRE SAFING: TESTED IN ACCORD WITH ASTM E119-12A WITHOUT DETERIORATION FOR MINIMUM OF FIVE HOURS IN A SLAB EDGE/SPANDREL CONFIGURATION. C. ACCESSORIES: 1. CLIPS: INSULATION MANUFACTURER'S STANDARD GALVANIZED STEEL IMPALING CLIPS FOR ATTACHMENT OF SAFING. 2. SEALANT: MANUFACTURER'S TESTED SEALANT MATERIAL FOR FOIL-FACED SMOKE SEAL. PART 3 - EXECUTION 3.1 PRE-INSTALLATION REQUIREMENTS: A. PRE-INSTALLATION MEETING: PRIOR TO BEGINNING FIRESTOPPING WORK, A PRE-INSTALLATION MEETING SHALL BE HELD TO REVIEW WORK TO BE ACCOMPLISHED. 1. CONTRACTOR, ARCHITECT, FIRESTOPPING SYSTEM MANUFACTURER'S REPRESENTATIVES, INSTALLER AND OTHER SUBCONTRACTORS WHOSE WORK INVOLVES FIRESTOPPING SHALL BE PRESENT. 2. CONTRACTOR SHALL NOTIFY ALL PARTIES AT LEAST SEVEN DAYS PRIOR TO TIME FOR MEETING. 3. CONTRACTOR SHALL RECORD MINUTES OF MEETING AND DISTRIBUTE TO ATTENDING PARTIES. 3.2 EXAMINATION: A. EXAMINE AREAS TO RECEIVE FIRESTOPPING MATERIALS PRIOR TO BEGINNING WORK. VERIFY THAT OPENING AREAS AND DIMENSIONS FOR PENETRATIONS TO RECEIVE FIRESTOPPING SYSTEMS AND DEVICES DO NOT EXCEED DESIGN REQUIREMENTS. B. REMOVE PROJECTIONS INTERFERING WITH INSTALLATION. PREPARE SURFACES IN ACCORD WITH MANUFACTURER'S PRODUCT DATA AND UL THROUGH-PENETRATION FIRESTOP DEVICES NUMBERS. 3.3 PREPARATION: A. PRIMING: PRIME SUBSTRATES WHERE RECOMMENDED BY FIRESTOPPING MANUFACTURER USING THAT MANUFACTURER'S RECOMMENDED PRODUCTS AND METHODS. CONFINE PRIMERS TO AREAS OF BOND. DO NOT ALLOW SPILLAGE AND MIGRATION ONTO EXPOSED SURFACES. B. MASKING TAPE: USE MASKING TAPE TO PREVENT FIRESTOPPING FROM CONTACTING ADJOINING SURFACES THAT WILL REMAIN EXPOSED UPON COMPLETION OF THE WORK. REMOVE TAPE AS SOON AS IT IS POSSIBLE TO DO SO WITHOUT DISTURBING THE FIRESTOPPING SEAL WITH SUBSTRATES. 3.4 INSTALLATION: A. GENERAL: 1. COMPLY WITH MANUFACTURER'S PRODUCT DATA AND UL CLASSIFIED FOR THROUGH-PENETRATION FIRESTOP DEVICES NUMBERS. 2. INSTALL FIRESTOPPING MATERIALS FITTED TO ADJACENT CONSTRUCTION TO FILL VOIDS. 3. FIRESTOP PENETRATIONS THROUGH FIRE-RATED WALLS, PARTITIONS, FLOORS AND FLOOR/CEILING ASSEMBLIES WITH TESTED ASSEMBLIES IN ACCORD WITH UL 1479 OR WITH A THROUGH-PENETRATION FIRESTOP SYSTEM OR DEVICE WHEN TESTED IN ACCORD WITH ASTM E814-11A. 4. FIRESTOPPING SHALL COMPLY WITH CODE REQUIREMENTS. B. FIRE AND SMOKE BARRIER IDENTIFICATION: 1. FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. 2. SUCH IDENTIFICATION SHALL BE ABOVE ANY DECORATIVE CEILING AND IN CONCEALED SPACES, AND NEAR THE TOP OF THE WALL OR BARRIER IN UNFINISHED SPACES. 3. SUCH IDENTIFICATION SHALL BE LETTERS A MINIMUM OF 2" (51 mm) HIGH ON A CONTRASTING BACKGROUND, SPACED AT 12'-0" O.C. MAXIMUM, WITH A MINIMUM OF ONE PER WALL OR BARRIER. COMPLY WITH CODE REQUIREMENTS. 4. SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS: "______ HOUR FIRE AND SMOKE BARRIER - PROTECT ALL OPENINGS." C. THROUGH-PENETRATION FIRESTOP SYSTEMS AND DEVICES: 1. INSTALL AT PENETRATIONS THROUGH FIRE-RATED FLOOR AND WALL CONSTRUCTION, INCLUDING PARTITIONS AND FLOOR/ CEILING ASSEMBLIES, IN ACCORD WITH MANUFACTURER'S PRODUCT DATA AND UL SYSTEM NUMBERS. PROVIDE MATERIALS AND ACCESSORIES AS REQUIRED. 2. INSTALL INTUMESCENT TYPE FIRESTOP SYSTEMS WHERE PLASTIC PIPING, CABLE, CONDUIT AND OTHER COMBUSTIBLE ITEMS, INCLUDING INSULATED METAL PIPES, PENETRATE FIRE-RATED CONSTRUCTION. 3. AT CONTRACTOR'S OPTION, THROUGH-PENETRATION FIRESTOP DEVICES OF SIMILAR FUNCTION MAY BE INSTALLED IN LIEU OF FIRESTOP SYSTEMS. 4. DO NOT REMOVE FORMING MATERIALS UNLESS SPECIFIED IN SYSTEM DESIGNS. D. FIRESTOP SEALANT: SEAL PERIMETERS, VOIDS AND JOINTS OF FIRE-RATED WALLS AND PARTITIONS,INCLUDING ABUTMENT OF FLOOR AND ROOF OR CEILING STRUCTURE, AND FLUTES OF METAL DECKING. 1. IF REQUIRED BY UL DESIGN, INSTALL MINERAL WOOL OR CERAMIC FIBER IN CAVITIES, PACKED FULL AND TIGHT WITH ALLOWANCE FOR SEALANT INSTALLATION. 2. SEAL BOTH FACES OF WALLS AND PARTITIONS WITH FIRESTOP SEALANT. TOOL SEALANTFLUSH WITH ADJACENT FINISH. 3. IN ACCORD WITH UL FIRE RESISTANCE DIRECTORY DESIGNS, PACKED CONCRETE AND MASONRY JOINTS SHALL BE SEALED USING FIRESTOP SEALANT OR USING SEALANT AS SPECIFIED IN JOINT SEALANTS SECTION. E. MINERAL FIBER SAFING: 1. INSTALL SAFING IN CAVITIES OF PENETRATIONS THROUGH NON-RATED FLOOR AND WALL CONSTRUCTION, INCLUDING SPACES AROUND PIPING, CONDUITS, CABLES AND DUCT PENETRATIONS. 2. INSTALL SAFING IN VOIDS AND JOINTS OF NON-RATED WALLS AND PARTITIONS ABUTTING METAL DECKING OF FLOOR AND ROOD STRUCTURES. PACK FLUTES OF METAL DECKING SOLID WITH SAFING MATERIAL. 3. SAFING SHALL BE INSTALLED AT JOINTS AND PENETRATIONS IN NON-RATED CONSTRUCTION NOT EXPOSED TO VIEW AND CONCEALED IN FINISH WORK. SECURE SAFING BY COMPRESSING INTO VOIDS OR JOINTS AND USING MANUFACTURER'S STANDARD CLIPS OR CLOSURE PLATES AS REQUIRED. F. SEAL VOIDS AND JOINTS OF NON-RATED WALLS AND PARTITIONS ABUTTING CONCRETE FLOOR AND ROOF CONSTRUCTION USING SEALANT AS SPECIFIED IN OTHER SECTIONS. 3.5 FIELD QUALITY CONTROL: A. INSPECTION: INDEPENDENT INSPECTION AGENCY EMPLOYED AND PAID BY OWNER , WILL EXAMINE PENETRATION FIRESTOPPING IN ACCORD WITH ASTM E2174-10 AND ASTM E2393-10A. INSPECTION AGENCY WILL EXAMINE FIRESTOPPING AND WILL DETERMINE, IN GENERAL, THAT FIRESTOPPING HAS BEEN INSTALLED IN COMPLIANCE WITH TESTED AND LISTED FIRESTOP SYSTEM, AND THAT INSTALLATION PROCESS CONFORMS TO FM 4991 - STANDARD FOR APPROVAL OF FIRESTOP CONTRACTORS OR UL QUALIFIED FIRESTOP CONTRACTOR PROGRAM. B. INSPECTOR WILL ADVISE CONTRACTOR OF DEFICIENCIES NOTED WITHIN ONE WORKING DAY. C. DO NOT PROCEED TO ENCLOSE FIRESTOPPING WITH OTHER CONSTRUCTION UNTIL INSPECTION AGENCY HAS VERIFIED FIRESTOP INSTALLATION COMPLIES WITH REQUIREMENTS OF CONTRACT DOCUMENTS. D. WHERE DEFICIENCIES ARE FOUND, REPAIR OR REPLACE FIRESTOPPING SO THAT IT COMPLIES WITH REQUIREMENTS OF TESTED AND LISTED SYSTEM DESIGN. 3.6 CLEANING: A. CLEAN OFF EXCESS FILL MATERIALS AND SEALANTS ADJACENT TO OPENINGS AND JOINTS AS WORK PROGRESSES. USE METHODS AND CLEANING MATERIALS APPROVED BY MANUFACTURERS OF FIRESTOPPING PRODUCTS AND OR ASSEMBLIES IN WHICH OPENINGS AND JOINTS OCCUR. B. PROTECT FIRESTOPPING DURING AND AFTER CURING PERIOD FROM CONTACT WITH CONTAMINATING SUBSTANCES. END OF SECTION SECTION 07 9200 - JOINT SEALANTS PART 1 - GENERAL 1.1 SUMMARY: A. DEFINITIONS: 1. JOINT SEALANT COMPOUND: A MATERIAL USED IN FILLING JOINTS AND SEAMS, HAVING PROPERTIES OF ADHESION AND COHESION; NOT REQUIRED TO HAVE EXTENSIBILITY AND RECOVERY PROPERTIES, GENERALLY FOR APPLICATION IN INTERIOR JOINTS NOT SUBJECT TO MOVEMENT. 2. CAULK: THE PROCESS OF FILLING JOINTS, WITHOUT REGARD TO TYPE OF MATERIAL. 3. JOINT FAILURE: A CAULKED JOINT EXHIBITING ONE OR MORE OF THE FOLLOWING CHARACTERISTICS: A. AIR AND/OR WATER LEAKAGE. B. MIGRATION AND/OR REVERSION. C. LOSS OF ADHESION. D. LOSS OF COHESION. E. FAILURE TO CURE. F. DISCOLORATION. G. STAINING OF ADJACENT WORK. H. DEVELOPMENT OF BUBBLES, AIR POCKETS OR VOIDS. 1.2 ACTION SUBMITTALS: A. PRODUCT DATA: SUBMIT MANUFACTURER'S PRODUCT DESCRIPTION, INDICATING CONFORMANCE WITH SPECIFIED REQUIREMENTS AND INSTALLATION INSTRUCTIONS FOR EACH TYPE OF SEALANT. INDICATE PREPARATION AND PRIMING REQUIREMENTS FOR EACH SUBSTRATE CONDITION. B. COLOR SAMPLES: 1. SAMPLES FOR INITIAL INSPECTION: SAMPLES SHALL BE ACTUAL MATERIALS OR LITERATURE DEPICTING ACTUAL COLORS OF STANDARD COLOR MATERIALS SHOWING FULL RANGE OF COLORS AVAILABLE FOR EACH PRODUCT EXPOSED TO VIEW. 2. SUBMIT SAMPLES OF CUSTOM COLOR SEALANT MATERIALS MATCHING COLOR SAMPLE PROVIDED BY ARCHITECT. 3. SAMPLES FOR VERIFICATION: FOR EACH KIND AND COLOR OF JOINT SEALANT REQUIRED, PROVIDE SAMPLES WITH JOINT SEALANTS IN 1/2" WIDE JOINTS FORMED BETWEEN TWO 6" LONG STRIPS OF MATERIAL MATCHING APPEARANCE OF EXPOSED SURFACES ADJACENT TO JOINT SEALANTS. 1.3 INFORMATIONAL SUBMITTALS: A. ADHESION COMPATIBILITY TEST RESULTS: SUBMIT A LETTER FROM SEALANT MANUFACTURER INDICATING ADHESION AND COMPATIBILITY TESTING HAS BEEN PERFORMED AND THAT MATERIALS ARE COMPATIBLE AND THAT ADHESION IS ACCEPTABLE. INDICATE REQUIREMENTS FOR PRIMERS OR SPECIAL PREPARATION. B. SUBSTRATE STAINING TEST RESULTS: SUBMIT A LETTER FROM SEALANT MANUFACTURER INDICATING THAT SUBSTRATE STAIN TESTING HAS BEEN PERFORMED ON ACTUAL SAMPLES OF SUBSTRATES INDICATED TO RECEIVE JOINT SEALANT AND THAT SEALANT WAS FOUND TO BE NON-STAINING TO SUBSTRATE. INDICATE REQUIREMENTS FOR PRIMERS OR SPECIAL PREPARATION TO MEET NON-STAINING REQUIREMENTS. C. JOINT SEALANT SCHEDULE: INCLUDE THE FOLLOWING INFORMATION: 1. JOINT-SEALANT APPLICATION, JOINT LOCATION, AND DESIGNATION. 2. JOINT-SEALANT MANUFACTURER AND PRODUCT NAME. 3. JOINT-SEALANT FORMULATION. 4. JOINT-SEALANT COLOR. 1.4 QUALITY ASSURANCE: A. APPLICABLE STANDARDS AS REFERENCED HEREIN: 1. ASTM INTERNATIONAL (ASTM). 2. UNITED STATES DEPARTMENT OF AGRICULTURE (USDA). B. ADHESION COMPATIBILITY TESTS: PERFORM TESTS ON ACTUAL SAMPLES OF ALUMINUM FRAMING SYSTEM COMPONENTS, TO DETERMINE THAT MATERIALS ARE COMPATIBLE AND THAT ADHESION IS ACCEPTABLE. IDENTIFY REQUIREMENTS FOR PRIMERS OR SPECIAL PREPARATION. C. SUBSTRATE STAINING TEST RESULTS: PERFORM TEST ON ACTUAL SAMPLES OF STONE VENEER TO RECEIVE JOINT SEALANT TO DETERMINE THAT SEALANT IS NON-STAINING TO SUBSTRATE. IDENTIFY REQUIREMENTS FOR PRIMERS OR SPECIAL PREPARATION TO MEET NON-STAINING REQUIREMENTS. 1. TEST POROUS SUBSTANCES IN ACCORD WITH ASTM C1248-08(2012). 2. TEST NON-POROUS SUBSTRATES IN ACCORD WITH ASTM D2203-01(2011). D. VOC CONTENT OF INTERIOR SEALANTS: SEALANTS AND SEALANT PRIMERS USED INSIDE THE WEATHERPROOFING SYSTEM SHALL HAVE A VOC CONTENT LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1113, ARCHITECTURAL COATING, RULES IN EFFECT JANUARY 1, 2004. E. ARCHITECT RESERVES THE RIGHT TO REJECT WORK NOT IN CONFORMANCE WITH SELECTED COLORS, BASED UPON SAMPLES SUBMITTED. 1.5 PROJECT/ SITE CONDITIONS: A. PROTECTION OF ADJACENT SURFACES: 1. PROTECT BY APPLYING MASKING MATERIAL OR MANIPULATING APPLICATION EQUIPMENT TO KEEP MATERIALS IN JOINT. IF MASKING MATERIALS ARE USED, ALLOW NO TAPE TO TOUCH CLEANED SURFACES TO RECEIVE SEALANT. REMOVE TAPE IMMEDIATELY AFTER CAULKING, BEFORE SURFACE SKIN BEGINS TO FORM. 2. REMOVE MISAPPLIED MATERIALS FROM SURFACES BY USING SOLVENTS AND METHODS RECOMMENDED BY MANUFACTURER. 3. AT SURFACES FROM WHICH MATERIALS HAVE BEEN REMOVED, RESTORE TO ORIGINAL CONDITION AND APPEARANCE. 1.6 WARRANTIES: A. INSTALLER'S WARRANTY: WARRANT WORK TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP, INCLUDING JOINT FAILURE, FOR A PERIOD OF TWO YEARS. B. WARRANTIES SHALL BEGIN AT DATE OF SUBSTANTIAL COMPLETION. PART 2 - PRODUCTS 2.1 ONE-PART, NON-SAG POLYURETHANE SEALANT: A. ACCEPTABLE PRODUCTS: 1. BASF BUILDING PRODUCTS, SONOLASTIC NP-1. 2. PECORA CORP., DYNATROL I-XL. 3. TREMCO, INC., AN RPM COMPANY, VULKEM 116 4. TREMCO, INC., AN RPM COMPANY, DYMONIC. B. CHARACTERISTICS: 1. TYPE: ONE-PART, NON-SAG POLYURETHANE-BASED SEALANT; MEETING ASTM C920-11, TYPE S, GRADE NS, CLASS 25, FOR USE NT. 2. COLORS: COLORS AS SELECTED BY ARCHITECT. 2.2 SILICONE BATH SEALANT FOR WET AREAS: A. ACCEPTABLE PRODUCTS: 1. BASF BUILDING SYSTEMS, OMNIPLUS. 2. DOW CORNING CORP., 786 MILDEW-RESISTANT SILICONE SEALANT. 3. FRANKLIN INTERNATIONAL, TITEBOND KITCHEN & BATH SEALANT. 4. GE ADVANCED MATERIALS, SANITARY SCS1700. 5. PECORA CORP., #898NST SILICONE SANITARY SEALANT. B. CHARACTERISTICS: 1. TYPE: ONE-PART SILICON RUBBER, MILDEW- AND STAIN-RESISTANT, ACID- CURING SILICONE SEALANT; MEETING ASTM C920-11, TYPE S, GRADE NS, CLASS 25, FOR USE NT. 2. COLOR: CLEAR, WHITE OR OFF-WHITE, AS SELECTED BY ARCHITECT. 2.3 TWO-PART POLYURETHANE SEALANT FOR HORIZONTAL TRAFFIC-BEARING PAVEMENTS: A. ACCEPTABLE PRODUCTS: 1. BASF BUILDING SYSTEMS, SONOLASTIC SL 2. 2. PECORA CORP., UREXPAN NR-200. 3. TREMCO, INC., AN RPM COMPANY, 45 SSL. B. CHARACTERISTICS: 1. TYPE: TWO-COMPONENT POLYURETHANE SEALANT FOR HORIZONTAL TRAFFIC-BEARING SURFACES MEETING ASTM C920-11, TYPE M, GRADE P OR NS, MINIMUM CLASS 25, FOR USE T; SELF-LEVELING FOR FLAT SURFACES AND NON-SAG FOR SLOPED SURFACES. 2. COLORS: COLORS AS SELECTED BY ARCHITECT. 2.4 SOLVENT-RELEASE-CURING ACRYLIC SEALANT: A. ACCEPTABLE PRODUCTS: 1. FRANKLIN INTERNATIONAL, TITEBOND PAINTERS PLUS CAULK. 2. SCHNEE-MOREHEAD, INC., ACRYL-R ACRYLIC SEALANT. 3. TREMCO, INC., AN RPM COMPANY, MONO 555. B. CHARACTERISTICS: 1. TYPE: ONE-PART, ACRYLIC POLYMER SEALANT, MEETING ASTM C1311-11. 2. COLORS: STANDARD COLORS AS SELECTED BY ARCHITECT. 2.5 PAINTABLE ACRYLIC-LATEX JOINT SEALANT: A. ACCEPTABLE PRODUCTS: 1. BASF BUILDING SYSTEMS, SONOLASTIC SONOLAC. 2. BOSTIK, CHEM-CALK 600. 3. FRANKLIN INTERNATIONAL, TITEBOND PAINTERS CAULK. 4. GE ADVANCED MATERIALS, RCS20. 5. PECORA CORP., AC-20 ACRYLIC LATEX. 6. TREMCO, INC., AN RPM COMPANY, TREMFLEX 834. B. CHARACTERISTICS: FLEXIBLE, PAINTABLE, NON-STAINING, NON-BLEEDING ACRYLIC LATEX OR SILICONIZED ACRYLIC EMULSION, MEETING ASTM C834-10, TYPE OP, GRADE NF. 2.6 ACCESSORY MATERIALS: A. JOINT CLEANER: TYPE RECOMMENDED BY MATERIAL MANUFACTURER FOR SUBSTRATES INDICATED. B. JOINT PRIMER/SEALER: TYPE RECOMMENDED BY MATERIAL MANUFACTURER FOR SUBSTRATES, CONDITIONS AND EXPOSURES INDICATED. C. BOND BREAKER TAPE: PLASTIC TAPE APPLIED TO CONTACT SURFACES WHERE BOND TO SUBSTRATE OR JOINT FILLER MUST BE AVOIDED FOR MATERIAL PERFORMANCE. D. SEALANT BACKER ROD: COMPRESSIBLE ROD STOCK AS RECOMMENDED BY SEALANT MANUFACTURER FOR COMPATIBILITY WITH SEALANT. PROVIDE SIZE AND SHAPE OF ROD TO CONTROL JOINT DEPTH. E. TOOLING AGENT: AGENT RECOMMENDED BY MATERIAL MANUFACTURER TO ENSURE CONTACT OF MATERIAL WITH INNER JOINT FACES. PART 3 - EXECUTION 3.1 JOB MOCK-UP: A. PREPARE, CAULK AND FINISH ONE MOCK-UP SAMPLE OF EACH JOINT CONDITION. B. SAMPLE JOINTS SHALL BE APPROVED BY ARCHITECT PRIOR TO BEGINNING WORK. APPROVED, UNDAMAGED MOCK-UP JOINTS SHALL SERVE AS A STANDARD OF QUALITY FOR THE REMAINDER OF THE WORK. 3.2 JOINT SURFACE PREPARATION: A. CLEAN JOINTS OF DEBRIS AND PROJECTIONS INCLUDING SHIMS. B. CLEAN JOINT SURFACES IMMEDIATELY BEFORE CAULKING JOINTS. REMOVE DIRT, INSECURE COATINGS, MOISTURE AND OTHER SUBSTANCES WHICH WOULD INTERFERE WITH BOND. C. ROUGHEN JOINT SURFACES OF NON-POROUS MATERIALS, UNLESS MATERIAL MANUFACTURER'S PRODUCT DATA INDICATES EQUAL BOND STRENGTH AS POROUS SURFACES. RUB WITH FINE ABRASIVE CLOTH OR WOOL TO PRODUCE DULL SHEEN. 3.3 APPLICATION: A. COMPLY WITH JOINT SEALANT MATERIAL MANUFACTURER'S PRODUCT DATA AND ASTM C1193-09 EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE SPECIFIED. B. PRIME JOINT SURFCES WHERE RECOMMENDED BY MATERIAL MANUFACTURER. DO NOT ALLOW PRIMER/SEALER TO SPILL OR MIGRATE ONTO ADJACENT SURFACES. C. INSTALL BACKER ROD FOR JOINT SEALANT MATERIALS, EXCEPT WHERE RECOMMENDED BY MATERIAL MANUFACTURER TO BE OMITTED FOR APPLICATION INDICATED. 1. PLACE BACKER ROD TO MAINTAIN RECOMMENDED SEALANT THICKNESS AND PROFILE. 2. PLACE ROD AT DEPTH TO PROVIDE SEALANT MANUFACTURER'S RECOMMENDED SEALANT DEPTH. 3. DO NOT TWIST ROD DURING INSTALLATION. 4. PLACE ROD TO MINIMIZE POSSIBILITY OF EXTRUSION WHEN JOINT IS COMPRESSED. 5. INSTALL BOND BREAKER TAPE IN LIEU OF BACKER ROD FOR SHALLOW, CLOSED JOINTS AND AS RECOMMENDED BY MANUFACTURER'S PRODUCT DATA. D. EMPLOY INSTALLATION TECHNIQUES WHICH WILL ENSURE THAT MATERIALS ARE DEPOSITED IN UNIFORM, CONTINUOUS RIBBONS WITHOUT GAPS OR AIR POCKETS, WITH COMPLETE WETTING OF JOINT BOND SURFACES. WHERE HORIZONTAL JOINTS ARE BETWEEN A HORIZONTAL SURFACE AND A VERTICAL SURFACE, FILL JOINT TO FORM SLIGHT COVE SO THAT JOINT WILL NOT TRAP MOISTURE AND DEBRIS. E. DO NOT ALLOW MATERIALS TO OVERFLOW ONTO ADJACENT SURFACES. PREVENT STAINING OF ADJACENT SURFACES. F. REMOVE EXCESS AND MISPLACED MATERIALS AS WORK PROGRESSES. CLEAN THE ADJOINING SURFACES TO REMOVE MISPLACED MATERIALS, WITHOUT DAMAGE TO ADJACENT SURFACES OR FINISHES. G. INTERIOR JOINTS: AT INTERIOR JOINTS AND SEAMS AT ABUTTING AND ADJACENT MATERIALS, RECESS JOINT SEALANT 3/16" IN JOINTS WIDER THAN 1/4". AT JOINTS 1/4" OR LESS IN WIDTH, TOOL JOINT SEALANT FLUSH. H. TOOL JOINTS OF NON-SAG SEALANT TO CONCAVE PROFILE AND SMOOTH, UNIFORM SURFACE, FLUSH WITH EDGES OF SUBSTRATE. MAINTAIN SEALANT DEPTH-TO-WIDTH RATIO IN ACCORD WITH MANUFACTURER'S PRODUCT DATA. I. CURE JOINT SEALANTS IN ACCORD WITH MANUFACTURER'S PRODUCT DATA TO OBTAIN HIGH EARLY BOND STRENGTH, INTERNAL COHESIVE STRENGTH AND SURFACE DURABILITY. PROTECT UNCURED SURFACES FROM CONTAMINATION AND PHYSICAL DAMAGE. 3.4 JOINT SEALANT SCHEDULE: A. INTERIOR JOINTS AT PERIMETER OF WINDOWS AND OF HOLLOW METAL FRAMING: ONE-PART, NON-SAG POLYURETHANE SEALANT. B. INTERIOR CONCEALED BEDDING JOINTS AND THRESHOLDS: SOLVENT-RELEASE-CURING ACRYLIC SEALANT. C. INTERIOR HORIZONTAL TRAFFIC-BEARING JOINTS, EXCLUDING TILE FLOOR JOINTS: TWO-PART POLYURETHANE SEALANT. D. FIRESTOPPED JOINTS: FIRESTOP SEALANT AS SPECIFIED IN FIRESTOPPING SECTION. E. TYPICAL INTERIOR JOINTS AND SEAMS AT ABUTTING AND ADJACENT MATERIALS EXCEPT AS SPECIFIED HEREIN: PAINTABLE ACRYLIC-LATEX JOINT SEALANT. F. INTERIOR JOINTS IN CONJUNCTION WITH FIXTURES AND TILE FINISHES: SILICONE BATH SEALANT. END OF SECTION SECTION 08 1416 - FLUSH WOOD DOORS PART 1 - GENERAL 1.01 SUMMARY A. SECTION INCLUDES: 1. WOOD DOORS. B. RELATED REQUIREMENTS: 1. DIVISION 01 - GENERAL REQUIREMENTS. 2. SECTION 09 9000 - PAINTING AND COATING. 1.02 DESIGN REQUIREMENTS A. DRAWINGS INDICATE SIZES, LOCATIONS AND GENERAL DETAILS OF WOOD DOOR CONSTRUCTION AND INSTALLATION. B. REGULATORY REQUIREMENTS: 1. FIRE RATED DOORS SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING AND CERTIFICATION AGENCY IN ACCORDANCE WITH LOCAL BUILDING CODES AND ACCEPTABLE TO THE AUTHORITIES HAVING JURISDICTION. THE LISTED DOORS SHALL MEET OR EXCEED THE REQUIREMENTS OF UL10B, NFPA 252 AND NFPA 80. ALL DOOR REQUIRING FIRE-RATING SHALL CARRY EITHER A UL OR ITS (INTERTEK TESTING SERVICES-WARNOCK HERSEY) LABEL. 2. ASTM E2074 – STANDARD TEST METHOD FOR FIRE TESTS OF DOOR ASSEMBLIES, INCLUDING POSITIVE PRESSURE ON SIDE-HINGED AND PIVOTED SWINGING DOOR ASSEMBLIES. 1.03 SUBMITTALS A. SHOP DRAWINGS: SUBMIT SCHEDULES, PLANS, ELEVATIONS AND DETAILS INDICATING DOOR CONSTRUCTION DETAILS, OPENING IDENTIFICATION SYMBOLS, SIZES, DOOR TYPE AND GRADE, FIRE CLASSIFICATION, SWING, LIGHT AND LOUVER CUTOUT SIZE AND LOCATIONS, AND UNDERCUTS. B. PRODUCT DATA: SUBMIT MANUFACTURERS TECHNICAL DATA FOR EACH SPECIFIED DOOR TYPE, INCLUDING DETAILS OF WOOD SPECIES, DESIGN AND CONSTRUCTION, FACTORY FINISHING SPECIFICATIONS AND INSTALLATION INSTRUCTIONS. C. COLOR/FINISH SAMPLES: SUBMIT SAMPLES OF NOT LESS THAN 4-INCH BY 6-INCH ON REPRESENTATIVE DOOR FINISH AND SAMPLES OF 3-INCH BY 8-INCH FOR THE EXPOSED EDGES. EACH SAMPLE SHALL BEAR A LABEL IDENTIFYING THE JOB NAME, ARCHITECT, CONTRACTOR AND THE WOODWORK INSITUTE FINISH SYSTEM NUMBER. 1.04 QUALITY ASSURANCE A. WOOD DOORS CONSTRUCTION, MANUFACTURE, AND FABRICATION SHALL CONFORM TO ANSI/WDMA I.S. 1-A, CUSTOM GRADE, EXTRA HEAVY DUTY GRADE INCLUDING THE LATEST REVISIONS, AND SPECIAL REQUIREMENTS SPECIFIED. B. DOORS SHALL BE FABRICATED, HARDWARE FACTORY FITTED AND MACHINED, AND FACTORY FINISHED, UNLESS NOTED OTHERWISE. C. WOOD DOOR FINISHES SHALL COMPLY WITH THE ARCHITECTURAL WOODWORK INSTITUTE STANDARDS. D. DOORS SHALL BE PRODUCTS OF ONE MANUFACTURER. E. DOOR MODIFICATIONS ARE NOT PERMITTED, UNLESS REVIEWED BY THE ARCHITECT OF RECORD. 1.05 DELIVERY, STORAGE AND HANDLING A. DELIVER MATERIALS IN MANUFACTURERS ORIGINAL, UNOPENED, UNDAMAGED CONTAINERS WITH IDENTIFICATION LABELS INTACT. B. DELIVER DOORS TO THE PROJECT SITE ONLY AFTER BUILDING HAS BEEN PROVIDED WITH DESIGN TEMPERATURE AND HUMIDITY. C. STORE AND HANDLE IN ACCORDANCE WITH ANSI/WDMA I.S.1-A. STORE DOORS PROTECTED FROM EXPOSURE TO HARMFUL CONDITIONS AND AT TEMPERATURE AND HUMIDITY CONDITIONS RECOMMENDED BY THE MANUFACTURER. 1.06 PROJECT CONDITIONS A. DO NOT INSTALL DOORS UNTIL BUILDING IS ENCLOSED AND AMBIENT CONDITIONS ARE WITHIN THE TEMPERATURE AND HUMIDITY RANGE RECOMMENDED BY DOOR MANUFACTURER. 1.07 WARRANTY A. MANUFACTURER SHALL PROVIDE A LIFE TIME MATERIAL WARRANTY FOR INTERIOR DOORS. B. INSTALLER SHALL PROVIDE A TWO YEAR FABRICATION AND INSTALLATION WARRANTY FOR ALL DOORS. PART 2 - PRODUCTS 2.01 MANUFACTURERS A. PROVIDE PRODUCTS MANUFACTURED BY ONE OF THE FOLLOWING: 1. ALGOMA HARDWOOD INC. 2. MARSHFIELD DOOR SYSTEMS. 3. EGGERS INDUSTRIES. 4. OR EQUAL. 2.02 DOOR CONSTRUCTION A. LAMINATED, SHIELDED CORE, WXR&20PP, 20&MIN. 1. THICKNESS: 1-3/4 INCH. A. CLEAR FINISH: 1) GRADE: PREMIUM. 2) FACE: PLAIN SLICED WHITE MAPLE. 2. CROSSBANDS: HARDWOOD VENEER OR ENGINEERED HIGH DENSITY FIBERBOARD, 1/16 INCH THICK. 3. SIDE EDGES: 3/4 INCH, VENEER TO MATCH FACE VENEER, BONDED TO CORE. FACTORY INSTALL CONCEALED INTUMESCENT SEALS PER UL 10C FOR POSITIVE PRESSURE FIRE DOORS. 4. TOP AND BOTTOM EDGES: 1&1/8 INCH, BONDED TO CORE. FACTORY INSTALL INTUMESCENT SEALS AT TOP RAIL PER UL 10C FOR POSITIVE PRESSURE FIRE DOORS. 5. FACE ASSEMBLY ADHESIVE: TYPE I, WATERPROOF. 6. CORE ASSEMBLY ADHESIVE: TYPE II, WATER&RESISTANT. 7. CORE: BONDED LOW DENSITY STAVED WOOD. 8. MOISTURE STRIPPING: NOT APPLICABLE. 9. SHIELDING: SHEET LEAD BONDED ONE SIDE OR TWO SIDES TO CROSSBAND, THICKNESS TO CONFORM TO SHIELDING REQUIREMENTS OF WALL IN WHICH DOOR IS INSTALLED. 10. BLOCKING FOR HARDWARE: FLAME RESISTANT, 6 INCH TOP EDGE FOR CLOSERS, 5.5 INCHES FOR BOTTOM HARDWARE OR AUTOMATIC CLOSERS WHERE APPLICABLE, 5 X 18 INCH LOCK BLOCKS, 5.5 INCH CROSS BLOCKING FOR PANIC HARDWARE, 5 X 12 INCH FOR FLOOR CLOSERS OR PIVOT HINGES WHERE APPLICABLE. 11. ALGOMA HARDWOODS, INC.'S "ALGOMA GRADE LEAD LINED DOOR, FD 1/3 HOUR"; MARSHFIELD DOOR SYSTEMS, INC.'S "X-RAY DOOR WXR-20"; EGGERS INDUSTRIES, "LEAD SHIELD DOOR & 20 MINUTE FIRE DOOR. 2.03 FABRICATION A. FABRICATE FIRE&RATED DOORS IN ACCORDANCE WITH WI QUALITY STANDARDS AND WDMAI.S.1 & A & LATEST EDITION AND TO UL OR WH REQUIREMENTS. ATTACH PERMANENT METAL FIRE & RATING LABEL TO DOOR EDGE, EITHER ON HINGE STILE OR TOP EDGE. B. PRE & MACHINE DOORS AT FACTORY FOR FINISH HARDWARE. CUTOUTS FOR HARDWARE IN DOORS HAVING A FIRE RATING OF 20 MINUTES OR MORE SHALL BE ACCOMPLISHED AT THE FACTORY BEFORE LABELS ARE AFFIXED. PREPARATION SHALL BE PERFORMED IN ACCORDANCE WITH MANUFACTURER’S INSPECTION SERVICE PROCEDURE AND UNDER LABEL SERVICE. C. VENEER: FACE VENEER GRAIN SHALL RUN VERTICALLY; CROSSBAND VENEER RUN HORIZONTALLY. 2.04 FACTORY FINISH A. FACTORY FINISH: PREMIUM FINISH, MEET OR EXCEED PERFORMANCE STANDARDS OF WI SYSTEM CATALYZED POLYURETHANE. FACTORY & FINISHED DOORS SHALL BE INSTALLED JUST PRIOR TO SUBSTANTIAL COMPLETION. 1. CLEAR FINISH: WI SYSTEM 5, CATALYZED POLYURETHANE. PART 3 - EXECUTION 3.1 EXAMINATION A. VERIFY THAT OPENINGS ARE READY TO RECEIVE WORK AND FIELD MEASUREMENTS ARE AS INDICATED ON SHOP DRAWINGS. B. BEGINNING OF INSTALLATION MEANS ACCEPTANCE OF EXISTING CONDITIONS. C. PRODUCT SCHEDULE: FOR HOLLOW-METAL DOORS AND FRAMES, PREPARED BY OR UNDER THE SUPERVISION OF SUPPLIER, USING SAME REFERENCE NUMBERS FOR DETAILS AND OPENINGS AS THOSE ON DRAWINGS. COORDINATE WITH FINAL DOOR HARDWARE SCHEDULE. 1.7 INFORMATIONAL SUBMITTALS A. PRODUCT TEST REPORTS: FOR EACH TYPE OF HOLLOW-METAL DOOR AND FRAME ASSEMBLY, FOR TESTS PERFORMED BY A QUALIFIED TESTING AGENCY. B. OVERSIZE CONSTRUCTION CERTIFICATION: FOR ASSEMBLIES REQUIRED TO BE FIRE-RATED AND EXCEEDING LIMITATIONS OF LABELED ASSEMBLIES. 1.8 DELIVERY, STORAGE, AND HANDLING A. DELIVER HOLLOW-METAL DOORS AND FRAMES PALLETIZED, PACKAGED, OR CRATED TO PROVIDE PROTECTION DURING TRANSIT AND PROJECT-SITE STORAGE. DO NOT USE NONVENTED PLASTIC. 1. PROVIDE ADDITIONAL PROTECTION TO PREVENT DAMAGE TO FACTORY-FINISHED UNITS. B. DELIVER WELDED FRAMES WITH TWO REMOVABLE SPREADER BARS ACROSS BOTTOM OF FRAMES, TACK WELDED TO JAMBS AND MULLIONS. C. STORE HOLLOW-METAL DOORS AND FRAMES VERTICALLY UNDER COVER AT PROJECT SITE WITH HEAD UP. PLACE ON MINIMUM 4-INCH- HIGH WOOD BLOCKING. PROVIDE MINIMUM 1/4-INCH SPACE BETWEEN EACH STACKED DOOR TO PERMIT AIR CIRCULATION. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. CECO DOOR; ASSA ABLOY. 2. CURRIES COMPANY; ASSA ABLOY. 3. REPUBLIC DOORS AND FRAMES. 4. OR APPROVED EQUAL B. SOURCE LIMITATIONS: OBTAIN HOLLOW-METAL DOOR AND FRAMES FROM SINGLE SOURCE FROM SINGLE MANUFACTURER. 2.2 PERFORMANCE REQUIREMENTS A. FIRE-RATED ASSEMBLIES: COMPLYING WITH NFPA 80 AND LISTED AND LABELED BY A QUALIFIED TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION FOR FIRE-PROTECTION RATINGS AND TEMPERATURE-RISE LIMITS INDICATED, BASED ON TESTING AT POSITIVE PRESSURE ACCORDING TO NFPA 252 OR UL 10C. 1. SMOKE- AND DRAFT-CONTROL ASSEMBLIES: PROVIDE ASSEMBLIES WITH GASKETS LISTED AND LABELED FOR SMOKE AND DRAFT CONTROL BY A QUALIFIED TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, BASED ON TESTING ACCORDING TO UL 1784 AND INSTALLED IN COMPLIANCE WITH NFPA 105. B. FIRE-RATED, BORROWED-LITE ASSEMBLIES: COMPLYING WITH NFPA 80 AND LISTED AND LABELED BY A QUALIFIED TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, FOR FIRE-PROTECTION RATINGS INDICATED, BASED ON TESTING ACCORDING TO NFPA 257 OR UL 9. 2.3 INTERIOR STANDARD STEEL DOORS AND FRAMES A. CONSTRUCT HOLLOW-METAL DOORS AND FRAMES TO COMPLY WITH STANDARDS INDICATED FOR MATERIALS, FABRICATION, HARDWARE LOCATIONS, HARDWARE REINFORCEMENT, TOLERANCES, AND CLEARANCES, AND AS SPECIFIED. B. HEAVY-DUTY DOORS AND FRAMES: SDI A250.8, LEVEL 2; SDI A250.4, LEVEL B PROVIDE AT ALL SCHEDULED INTERIOR DOOR LOCATIONS EXCEPT STAIRWELLS. 1. DOORS: A. TYPE: AS INDICATED IN THE DOOR SCHEDULE. B. THICKNESS: AS INDICATED IN THE DOOR SCHEDULE. C. FACE: AS INDICATED IN THE DOOR SCHEDULE. D. EDGE CONSTRUCTION: MODEL 2, SEAMLESS. E. EDGE BEVEL: PROVIDE MANUFACTURER'S STANDARD BEVELED OR SQUARE EDGES. F. CORE: MANUFACTURER'S STANDARD. G. FIRE-RATED CORE: MANUFACTURER'S STANDARD CORE FOR FIRE-RATED AND TEMPERATURE-RISE-RATED DOORS. 2. FRAMES: A. MATERIALS: UNCOATED STEEL SHEET, MINIMUM THICKNESS OF 0.059 INCH. B. SIDELITE AND TRANSOM FRAMES: FABRICATED FROM SAME THICKNESS MATERIAL AS ADJACENT DOOR FRAME. C. CONSTRUCTION: FULL PROFILE WELDED. 3. EXPOSED FINISH: PRIME. 2.4 FRAME ANCHORS A. JAMB ANCHORS: 1. TYPE: ANCHORS OF MINIMUM SIZE AND TYPE REQUIRED BY APPLICABLE DOOR AND FRAME STANDARD, AND SUITABLE FOR PERFORMANCE LEVEL INDICATED. 2. QUANTITY: MINIMUM OF THREE ANCHORS PER JAMB, WITH ONE ADDITIONAL ANCHOR FOR FRAMES WITH NO FLOOR ANCHOR. PROVIDE ONE ADDITIONAL ANCHOR FOR EACH 24 INCHES OF FRAME HEIGHT ABOVE 7 FEET. B. FLOOR ANCHORS: PROVIDE FLOOR ANCHORS FOR EACH JAMB AND MULLION THAT EXTENDS TO FLOOR. C. FLOOR ANCHORS FOR CONCRETE SLABS WITH UNDERLAYMENT: ADJUSTABLE-TYPE ANCHORS WITH EXTENSION CLIPS, ALLOWING NOT LESS THAN 2-INCH HEIGHT ADJUSTMENT. TERMINATE BOTTOM OF FRAMES AT TOP OF UNDERLAYMENT. D. MATERIAL: ASTM A 879/A 879M, COMMERCIAL STEEL (CS), 04Z COATING DESIGNATION; MILL PHOSPHATIZED. 1. FOR ANCHORS BUILT INTO EXTERIOR WALLS, STEEL SHEET COMPLYING WITH ASTM A 1008/A 1008M OR ASTM A 1011/A 1011M; HOT-DIP GALVANIZED ACCORDING TO ASTM A 153/A 153M, CLASS B. 2.5 MATERIALS A. COLD-ROLLED STEEL SHEET: ASTM A 1008/A 1008M, COMMERCIAL STEEL (CS), TYPE B; SUITABLE FOR EXPOSED APPLICATIONS. B. HOT-ROLLED STEEL SHEET: ASTM A 1011/A 1011M, COMMERCIAL STEEL (CS), TYPE B; FREE OF SCALE, PITTING, OR SURFACE DEFECTS; PICKLED AND OILED. C. METALLIC-COATED STEEL SHEET: ASTM A 653/A 653M, COMMERCIAL STEEL (CS), TYPE B. D. INSERTS, BOLTS, AND FASTENERS: HOT-DIP GALVANIZED ACCORDING TO ASTM A 153/A 153M. E. POWER-ACTUATED FASTENERS IN CONCRETE: FASTENER SYSTEM OF TYPE SUITABLE FOR APPLICATION INDICATED, FABRICATED FROM CORROSION-RESISTANT MATERIALS, WITH CLIPS OR OTHER ACCESSORY DEVICES FOR ATTACHING HOLLOW-METAL FRAMES OF TYPE INDICATED. F. MINERAL-FIBER INSULATION: ASTM C 665, TYPE I (BLANKETS WITHOUT MEMBRANE FACING); CONSISTING OF FIBERS MANUFACTURED FROM SLAG OR ROCK WOOL; WITH MAXIMUM FLAME-SPREAD AND SMOKE-DEVELOPED INDEXES OF 25 AND 50, RESPECTIVELY; PASSING ASTM E 136 FOR COMBUSTION CHARACTERISTICS. G. GLAZING: COMPLY WITH REQUIREMENTS IN SECTION 088000 "GLAZING." H. DOOR SILENCERS: 1/2 INCH DIAMETER TAMPER-PROOF GREY RUBBER CONE-SHAPED PLUGS. 2.6 FABRICATION A. HOLLOW-METAL FRAMES: FABRICATE IN ONE PIECE EXCEPT WHERE HANDLING AND SHIPPING LIMITATIONS REQUIRE MULTIPLE SECTIONS. WHERE FRAMES ARE FABRICATED IN SECTIONS, PROVIDE ALIGNMENT PLATES OR ANGLES AT EACH JOINT, FABRICATED OF METAL OF SAME OR GREATER THICKNESS AS FRAMES. 1. PROVIDE COUNTERSUNK, FLAT- OR OVAL-HEAD EXPOSED SCREWS AND BOLTS FOR EXPOSED FASTENERS UNLESS OTHERWISE INDICATED. 2. DOOR SILENCERS: EXCEPT ON WEATHER-STRIPPED FRAMES, DRILL STOPS TO RECEIVE DOOR SILENCERS AS FOLLOWS. KEEP HOLES CLEAR DURING CONSTRUCTION. A. SINGLE-DOOR FRAMES: DRILL STOP IN STRIKE JAMB TO RECEIVE THREE DOOR SILENCERS. B. HARDWARE PREPARATION: FACTORY PREPARE HOLLOW-METAL DOORS AND FRAMES TO RECEIVE TEMPLATED CYLINDRICAL HARDWARE, AND ELECTRICAL WIRING; INCLUDE CUTOUTS, REINFORCEMENT, DRILLING, AND TAPPING ACCORDING TO SDI A250.6, THE DOOR HARDWARE SCHEDULE, AND TEMPLATES. 1. REINFORCE DOORS AND FRAMES TO RECEIVE NONTEMPLATED, CYLINDRICAL, AND SURFACE-MOUNTED DOOR HARDWARE. 2. COMPLY WITH BHMA A156.115 FOR PREPARING HOLLOW-METAL DOORS AND FRAMES FOR HARDWARE. 2.7 STEEL FINISHES A. PRIME FINISH: CLEAN, PRETREAT, AND APPLY MANUFACTURER'S STANDARD PRIMER. 1. SHOP PRIMER: MANUFACTURER'S STANDARD, FAST-CURING, LEAD- AND CHROMATE-FREE PRIMER COMPLYING WITH SDI A250.10; RECOMMENDED BY PRIMER MANUFACTURER FOR SUBSTRATE; COMPATIBLE WITH SUBSTRATE AND FIELD-APPLIED COATINGS DESPITE PROLONGED EXPOSURE. PART 3 - EXECUTION 3.1 PREPARATION A. REMOVE WELDED-IN SHIPPING SPREADERS INSTALLED AT FACTORY. RESTORE EXPOSED FINISH BY GRINDING, FILLING, AND DRESSING, AS REQUIRED TO MAKE REPAIRED AREA SMOOTH, FLUSH, AND INVISIBLE ON EXPOSED FACES. TOUCH UP FACTORY-APPLIED FINISHES WHERE SPREADERS ARE REMOVED. B. DRILL AND TAP DOORS AND FRAMES TO RECEIVE NONTEMPLATED, CYLINDRICAL, AND SURFACE-MOUNTED DOOR HARDWARE. 3.2 INSTALLATION A. GENERAL: INSTALL HOLLOW-METAL DOORS AND FRAMES PLUMB, RIGID, PROPERLY ALIGNED, AND SECURELY FASTENED IN PLACE. COMPLY WITH APPROVED SHOP DRAWINGS AND WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. B. HOLLOW-METAL FRAMES: COMPLY WITH SDI A250.11OR NAAMM-HMMA 840. 1. SET FRAMES ACCURATELY IN POSITION; PLUMBED, ALIGNED, AND BRACED SECURELY UNTIL PERMANENT ANCHORS ARE SET. AFTER WALL CONSTRUCTION IS COMPLETE, REMOVE TEMPORARY BRACES WITHOUT DAMAGE TO COMPLETED WORK. A. WHERE FRAMES ARE FABRICATED IN SECTIONS, FIELD SPLICE AT APPROVED LOCATIONS BY WELDING FACE JOINT CONTINUOUSLY; GRIND, FILL, DRESS, AND MAKE SPLICE SMOOTH, FLUSH, AND INVISIBLE ON EXPOSED FACES. TOUCH-UP FINISHES. B. INSTALL FRAMES WITH REMOVABLE STOPS LOCATED ON SECURE SIDE OF OPENING. 2. FLOOR ANCHORS: SECURE WITH POSTINSTALLED ANCHORS. A. FLOOR ANCHORS MAY BE SET WITH POWER-ACTUATED FASTENERS INSTEAD OF POSTINSTALLED EXPANSION ANCHORS IF SO INDICATED AND APPROVED ON SHOP DRAWINGS. 3. SOLIDLY PACK MINERAL-FIBER INSULATION INSIDE FRAMES. 4. INSTALLATION TOLERANCES: ADJUST HOLLOW-METAL FRAMES TO THE FOLLOWING TOLERANCES: A. SQUARENESS: PLUS OR MINUS 1/16 INCH, MEASURED AT DOOR RABBET ON A LINE 90 DEGREES FROM JAMB PERPENDICULAR TO FRAME HEAD. B. ALIGNMENT: PLUS OR MINUS 1/16 INCH, MEASURED AT JAMBS ON A HORIZONTAL LINE PARALLEL TO PLANE OF WALL. C. TWIST: PLUS OR MINUS 1/16 INCH, MEASURED AT OPPOSITE FACE CORNERS OF JAMBS ON PARALLEL LINES, AND PERPENDICULAR TO PLANE OF WALL. D. PLUMBNESS: PLUS OR MINUS 1/16 INCH, MEASURED AT JAMBS AT FLOOR. C. HOLLOW-METAL DOORS: FIT AND ADJUST HOLLOW-METAL DOORS ACCURATELY IN FRAMES, WITHIN CLEARANCES SPECIFIED BELOW. 1. NON-FIRE-RATED STEEL DOORS: COMPLY WITH SDI A250.8 OR NAAMM-HMMA 841 AND NAAMM-HMMA GUIDE SPECIFICATION INDICATED. D. GLAZING: COMPLY WITH INSTALLATION REQUIREMENTS IN SECTION 088000 "GLAZING" AND WITH HOLLOW-METAL MANUFACTURER'S WRITTEN INSTRUCTIONS. 3.3 CLEANING AND TOUCHUP A. PRIME-COAT TOUCHUP: IMMEDIATELY AFTER ERECTION, SAND SMOOTH RUSTED OR DAMAGED AREAS OF PRIME COAT AND APPLY TOUCHUP OF COMPATIBLE AIR-DRYING, RUST-INHIBITIVE PRIMER. B. TOUCHUP PAINTING: CLEANING AND TOUCHUP PAINTING OF ABRADED AREAS OF PAINT ARE SPECIFIED IN PAINTING SECTIONS. END OF SECTION DIVISION 8 - OPENINGS SECTION 08 1113 - HOLLOW METAL FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATION SECTIONS, APPLY TO THIS SECTION. 1.2 SUMMARY A. SECTION INCLUDES: 1. INTERIOR STANDARD STEEL DOORS AND FRAMES. 1.3 DEFINITIONS A. MINIMUM THICKNESS: MINIMUM THICKNESS OF BASE METAL WITHOUT COATINGS ACCORDING TO NAAMM-HMMA 803 OR SDI A250.8. 1.4 COORDINATION A. COORDINATE ANCHORAGE INSTALLATION FOR HOLLOW-METAL FRAMES. FURNISH SETTING DRAWINGS, TEMPLATES, AND DIRECTIONS FOR INSTALLING ANCHORAGES, INCLUDING SLEEVES, CONCRETE INSERTS, ANCHOR BOLTS, AND ITEMS WITH INTEGRAL ANCHORS. DELIVER SUCH ITEMS TO PROJECT SITE IN TIME FOR INSTALLATION. B. COORDINATE REQUIREMENTS FOR INSTALLATION OF DOOR HARDWARE, ELECTRIFIED DOOR HARDWARE, AND ACCESS CONTROL AND SECURITY SYSTEMS. 1.5 PREINSTALLATION MEETINGS A. PREINSTALLATION CONFERENCE: CONDUCT CONFERENCE AT PROJECT SITE. 1.6 ACTION SUBMITTALS A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT. 1. INCLUDE CONSTRUCTION DETAILS, MATERIAL DESCRIPTIONS, CORE DESCRIPTIONS, FIRE-RESISTANCE RATINGS, TEMPERATURE-RISE RATINGS, AND FINISHES. B. SHOP DRAWINGS: INCLUDE THE FOLLOWING: 1. ELEVATIONS OF EACH DOOR TYPE. 2. DETAILS OF DOORS, INCLUDING VERTICAL- AND HORIZONTAL-EDGE DETAILS AND METAL THICKNESSES. 3. FRAME DETAILS FOR EACH FRAME TYPE, INCLUDING DIMENSIONED PROFILES AND METAL THICKNESSES. 4. LOCATIONS OF REINFORCEMENT AND PREPARATIONS FOR HARDWARE. 5. DETAILS OF EACH DIFFERENT WALL OPENING CONDITION. 6. DETAILS OF ELECTRICAL RACEWAY AND PREPARATION FOR ELECTRIFIED HARDWARE, ACCESS CONTROL SYSTEMS, AND SECURITY SYSTEMS. 7. DETAILS OF ANCHORAGES, JOINTS, FIELD SPLICES, AND CONNECTIONS. 8. DETAILS OF ACCESSORIES. 9. DETAILS OF MOLDINGS, REMOVABLE STOPS, AND GLAZING. DIVISION 9 - FINISHES SECTION 09 2900 - GYPSUM BOARD PART 1 - GENERAL 1.1 SUMMARY: A RELATED WORK: 1. ROUGH CARPENTRY. 2. FINISH CARPENTRY AND MILLWORK. 3. PAINTING AND COATING. 4. WALL COVERINGS. 5. ELECTRICAL. 1.2 ACTION SUBMITTALS: A. PRODUCT DATA: INDICATE PRODUCT DESCRIPTION, INCLUDING COMPLIANCE WITH SPECIFIED REQUIREMENTS AND INSTALLATION REQUIREMENTS. INCLUDE SPECIFIC REQUIREMENTS FOR FIRE-RATED AND ACOUSTICALLY RATED PARTITIONS AND CEILING ASSEMBLIES. MARK MANUFACTURER'S BROCHURES TO INCLUDE ONLY THOSE PRODUCTS PROPOSED FOR USE. INCLUDE COMPLETE DETAILS OF SHAFTWALL SYSTEM. INCLUDE DETAILS FOR SUPPLEMENTARY FIRE PROTECTION AT PENETRATIONS AND LOCATIONS OF ACOUSTICAL SEALANT. 1.3 INFORMATIONAL SUBMITTALS: A. STRUCTURAL DESIGN CALCULATIONS: SUBMIT FOR ARCHITECT'S INFORMATION ONLY. INDICATE COMPLIANCE WITH SPECIFIED DESIGN CRITERIA. CALCULATIONS SHALL BEAR THE SEAL OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF CALIFORNIA. 1.4 QUALITY ASSURANCE: A. APPLICABLE STANDARDS; STANDARDS OF THE FOLLOWING: 1. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). 2. ASTM INTERNATIONAL (ASTM) AS REFERENCED HEREIN. 3. ASSOCIATION OF THE WALL AND CEILING INDUSTRIES - INTERNATIONAL (AWCI). 4. CEILINGS AND INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION (CISCA). 5. GYPSUM ASSOCIATION (GA). 6. STEEL STUD MANUFACTURERS ASSOCIATION (SSMA) 7. UNDERWRITERS LABORATORIES, INC. (UL) 8. INTERTEK TESTING SERVICES/WARNOCK HERSEY, INC. (WHI). 9. "RECOMMENDED SPECIFICATION, AWCI, CISCA AND PDCA. 10. PAINTING AND DECORATING CONTRACTORS OF AMERICA (PDCA). B. DESIGN CRITERIA: 1. SOUND RATING: CONSTRUCT DESIGNATED PARTITIONS IN ACCORD WITH MANUFACTURER'S PRODUCT DATA, AS SUBMITTED, FOR OBTAINING SOUND TRANSMISSION CLASS (STC) RATINGS AS INDICATED ON THE DRAWINGS, IN ACCORD WITH ASTM E90-09. 2. FIRE-RESISTANCE: COMPLY WITH FIRE-RESISTANCE DESIGNS INDICATED ON THE DRAWINGS. USE ONLY MANUFACTURERS AND TYPES OF MATERIALS AS REQUIRED BY INDICATED DESIGNS. DESIGNS WITH TESTS BY OTHERTHAN TESTING AGENCY LISTED MAY BE SUBMITTED FOR ARCHITECT'S ACCEPTANCE, SUBJECT TO PRIOR ACCEPTANCE BY GOVERNING AUTHORITIES. 1.5 DELIVERY, STORAGE AND HANDLING: A. DELIVERY: DELIVER MATERIALS IN ORIGINAL PACKAGES, CONTAINERS OR BUNDLES BEARING BRAND NAME, APPLICABLE STANDARD DESIGNATION AND NAME OF MANUFACTURER OR SUPPLIER. B. STORAGE: 1. STACK GYPSUM BOARD INSIDE BUILDING, OFF FLOOR ON PALLETS OR SIMILAR PLATFORMS PROVIDING CONTINUOUS SUPPORT FOR GYPSUM BOARD AND TO PREVENT SAGGING. STACK GYPSUM BOARD FLAT AND SO THAT LONG LENGTHS ARE NOT OVER SHORT LENGTHS. 2. PROTECT GYPSUM BOARD FROM DIRECT EXPOSURE TO RAIN, SUNLIGHT OR OTHER EXCESSIVE WEATHER CONDITIONS. 3. DO NOT OVERLOAD FLOOR SYSTEMS. 1.6 PROJECT/SITE CONDITIONS: A. ENVIRONMENTAL CONDITIONS: 1. DURING MECHANICAL APPLICATION OF GYPSUM BOARD, MAINTAIN ROOM TEMPERATURE AT NOT LESS THAN 40 DEGREES F. 2. DURING ADHESIVE APPLICATION OF GYPSUM BOARD, JOINT TREATMENT, TEXTURING, AND DECORATION, MAINTAIN ROOM TEMPERATURE NOT LESS THAN 50 DEGREES F FOR 48 HOURS PRIOR TO APPLICATION AND CONTINUOUSLY THEREAFTER UNTIL COMPLETELY DRY AND UNTIL PERMANENT HEATING SYSTEM IS IN OPERATION OR BUILDING IS OCCUPIED. B. VENTILATION: 1. PROVIDE VENTILATION DURING AND FOLLOWING ADHESIVE AND JOINT TREATMENT APPLICATIONS, AND DRYING AND CURING PERIODS. 2. USE TEMPORARY AIR CIRCULATORS IN ENCLOSED AREAS LACKING NATURAL VENTILATION. 3. UNDER SLOW DRYING CONDITIONS, ALLOW ADDITIONAL DRYING TIME BETWEEN COATS OF JOINT TREATMENT. 4. PROTECT INSTALLED MATERIALS FROM DRAFTS DURING HOT, DRY WEATHER. C. WHEN RECOMMENDATIONS OF MANUFACTURER'S PRODUCT DATA EXCEED THE ABOVE, COMPLY WITH REQUIREMENTS OF MANUFACTURER'S PRODUCT DATA. PART 2 - PRODUCTS 2.1 FRAMING MEMBERS: A. GYPSUM BOARD STUDS: MEETING REQUIREMENTS OF ASTM C645-11; CHANNEL TYPE, ROLL-FORMED FROM DIP GALVANIZED STEEL COMPLYING WITH ASTM A1003-09 AND WITH ASTM A653-11, G40 MINIMUM. 1. STUD SIZE: AS INDICATED ON DRAWINGS, EXCEPT MINIMUM 3-5/8" DEPTH WHERE PARTITION IS INDICATED TO RECEIVE TILE CLADDING FINISH. A. WALL: METAL STUDS, GALVANIZED STEEL. B. SHAFT WALLS: "C-H" STUDS, HOT-DIPPED GALVANIZED, GAUGES AS REQUIRED TO SUIT VARIOUS CLEAR-SPAN CONDITIONS. C. "KING STUDS": INDICATED ON DRAWINGS. 2. STUD GAUGE: AS INDICATED ON THE DRAWINGS AND AS REQUIRED BY MANUFACTURER'S PRODUCT DATA FOR HEIGHTS AND CONDITIONS OF USE, WITH MAXIMUM ALLOWABLE DEFLECTIONS AS FOLLOWS: A. VERTICAL SHAFTS: L/120 AT 10 PSF. B. ALL OTHER PARTITIONS: L/240 AT 5 PSF. 3. COMPLY WITH SUBMITTED DESIGN CALCULATIONS. B. FLOOR AND CEILING RUNNERS: HOT DIP GALVANIZED STEEL, 1" DEEP, MINIMUM, BY WIDTHS TO RECEIVE STUDS, SAME GAUGE AS STUDS. RUNNER TRACKS SHALL HAVE SLOTTED HOLES FOR ATTACHMENT TO STRUCTURE AND STUDS, FOR SLIP JOINTS WHERE REQUIRED BY MANUFACTURER'S PRODUCT DATA. 1. WALL: RUNNERS, GALVANIZED STEEL, SIZES AND SHAPES COMPATIBLE WITH METAL STUD SYSTEM. 2. SHAFT WALL: STEEL "J" RUNNERS, GALVANIZED STEEL. C. HEADER: BRADY CONSTRUCTION INNOVATIONS, INC., PRO-X HEADER, 54 MIL AND PRO-X CLIP, 54 MIL. 2.2 GYPSUM BOARD: A. REGULAR BOARD: MEETING ASTM C1396-11, THICKNESS INDICATED, TAPERED ROUNDED EDGES. B. FIRE-RETARDANT BOARD: MEETING ASTM C1396-11, TYPE X, THICKNESS INDICATED, TAPERED ROUNDED EDGES. C. INTERIOR CEILING BOARD: MEETING ASTM C1396-11, 5/8" THICKNESS, REGULAR GRADE, TAPERED EGDES. D. COREBOARD: MEETING ASTM C1396-11, 1" THICKNESS, SQUARE EDGES, FIRE-RETARDANT BOARD. E. MOLD AND MOISTURE RESISTANT BOARD: TREATED PAPER-FACED GYPSUM BOARD. 1. ACCEPTABLE PRODUCTS: A. AMERICAN GYPSUM, M-BLOC. B. NATIONAL GYPSUM, XP GYPSUM BOARD AND XP FIRE-SHIELD GYPSUM BOARD. C. UNITED STATES GYPSUM (USG), SHEETROCK MOLD TOUGH GYPSUM PANELS. 2. THICKNESS: 5/8" THICKNESS TYPE X GRADE FIRE-RATED BOARD, TAPERED EDGES. 3. DESCRIPTION: MOLD AND MOISTURE RESISTANT GYPSUM CORE ENCASED IN MOLD AND MOISTURE RESISTANT FACERS, WITH TAPERED LONG EDGES. PANELS SHALL COMPLY WITH ASTM C1396-11. 4. MOLD RESISTANCE: RESISTANT TO MOLD GROWTH WHEN TESTED IN ACCORD WITH ASTM D3273-12, SCORE OF 10. 5. WATER ABSORPTION: LESS THAN 5% OF BOARD WEIGHT WHEN TESTED IN ACCORD WITH ASTM C473-12. 6. JOINT TAPE: AS RECOMMENDED BY GYPSUM BOARD MANUFACTURER. 7. LIMITATIONS: DO NOT USE AS A TILE BACKER BOARD. 2.3 TILE BACKER BOARD: A. WATER-RESISTANT, COATED GLASS MAT BACKER BOARD FOR TILE: 1. ACCEPTABLE PRODUCT: G-P GYPSUM PRODUCTS, DENS-SHIELD FIREGUARD TILE BACKER. 2. CHARACTERISTICS: MEETING ASTM C1178-11, MINIMUM 1/2" THICKNESS, NON-COMBUSTABLE, 5/8" THICKNESS TYPE X, WATER-RESISTANT, SILICON BASED GYPSUM CORE, FIBERGLASS SURFACE MATS, FRONT AND BACK, COATED WITH WATER AND VAPOR RETARDANT COATING. 3. JOINT TAPE: FIBERGLASS MESH JOINT TAPE AS RECOMMENDED BY GYPSUM BOARD MANUFACTURER. 2.4 GYPSUM SHAFTWALL SYSTEM: A. ACCEPTABLE PRODUCTS; SUBJECT TO COMPLIANCE WITH SPECIFIED REQUIREMENTS: 1. AMERICAN GYPSUM, M-BLOC SHAFT LINER. 2. G-P GYPSUM PRODUCTS, DENSGLASS SHAFTLINER. 3. NATIONAL GYPSUM CO., EXP EXTENDED EXPOSURE SHAFTLINER. 4. TEMPLE-INLAND, GREENGLASS LINER BOARD. 5. U.S. GYPSUM CO., SHEETROCK GLASS-MAT LINER PANELS. B. MATERIALS: MOISTURE- AND MOLD-RESISTANT, NONCOMBUSTIBLE, TYPE X GYPSUM SHAFTLINER COREBOARD COATED WITH GLASS MAT FACINGS, METAL FRAMING MEMBERS, AND FIBER-REINFORCED GYPSUM BOARD WITH FIBERGLASS MAT FACE ON UNEXPOSED SIDE AND PAPER FACE ON EXPOSED SIDE. C. FIRE-RESISTIVE RATING: IN ACCORD WITH FIRE-RATED ASSEMBLY DESIGN INDICATED. 2.5 SOUND CONTROL MATERIALS: A. CONTRACTOR'S OPTION: BASED ON SOUND RATINGS AND FIRE-RESISTANCE RATINGS REQUIRED FOR ASSEMBLIES, CONTRACTOR MAY SELECT GLASS FIBER OR MINERAL WOOL SOUND ATTENUATION MATERIALS AS FOLLOWS: 1. GLASS FIBER SOUND ATTENUATION BATTS: A. ACCEPTABLE MANUFACTURERS: 1) CERTAINTEED CORP. 2) KNAUF INSULATION. 3) JOHNS MANVILLE CORP. 4) OWENS-CORNING CORP. B. CHARACTERISTICS: 1) TYPE: UNFACED FIBERGLASS BATTS FOR FRICTION FIT BETWEEN STUDS, COMPLYING WITH ASTM C665-12, TYPE1. 2) SURFACE BURNING CHARACTERISTICS: MAXIMUM 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT WHEN TESTED IN ACCORD WITH ASTM E84-12C. 3) ASSEMBLY STC: AS INDICATED ON DRAWINGS. 4) THICKNESS: AS INDICATED ON DRAWINGS, BUT MINIMUM 3-1/2" THICK TO ACHIEVE R-13. 2. MINERAL WOOL SOUND ATTENUATION BLANKETS: A. ACCEPTABLE MANUFACTURERS: 1) IIG, MINWOOL, LLC, MINWOOL SOUND ATTENUATION FIRE BATTS. 2) OWENS-CORNING CORP., SOUND ATTENUATION FIRE BATT. 3) U.S. GYPSUM CO., THERMAFIBER SAFB (SOUND ATTENUATION FIRE BLANKETS). OWENS-CORNING CORP. B. CHARACTERISTICS: 1) TYPE: PAPERLESS, SEMI-RIDIG MINERAL WOOL FIBER BLANKET COMPLYING WITH ASTM C665-12, TYPE 1. 2) DENSITY: MAXIMUM 4.0 PCF FOR 1" THICKNESS, AND MAXIMUM 2.5 PCF. FOR GREATER THICKNESSES. 3) SURFACE BURNING CHARACTERISTICS: MAXIMUM 15 FLAME SPREAD AND 5 SMOKE DEVELOPMENT WHEN TESTED IN ACCORD WITH ASTM E84-12C. 4) ASSEMBLY STC: AS INDICATED ON DRAWINGS. 5) THICKNESS: AS INDICATED ON DRAWINGS, BUT MINIMUM REQUIRED THICKNESS TO ACHIEVE R-13 B. ACOUSTICAL TAPE: CLOSED CELL POLYVINYL CHLORIDE FOAM TAPE, 1/4" THICKNESS BY 1" WIDE. C. ACOUSTICAL JOINT SEALANT: MANUFACTURER'S STANDARD NON-SAG, PAINTABLE, NON-STAINING LATEX SEALANT COMPLYING WITH ASTM C834-10. PRODUCT EFFECTIVELY REDUCES AIRBORNE SOUND TRANSMISSION THROUGH PERIMETER JOINTS AND OPENINGS IN BUILDING CONSTRUCTION AS DEMOSTRATED BY TESTING REPRESENTATIVEASSEMBLIES ACCORDING TO ASTM E90-09. 1. PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE ONE OF THE FOLLOWING: A. ACCUMETRIC LLC; BOSS 824 ACOUSTICAL SOUND SEALANT. B. GRABBER CONSTRUCTION PRODUCTS; ACOUSTICAL SEALANT GSC. C. PECORA CORPORATION; AC-20 FTR. D. SPECIFIED TECHNOLOGIES, INC.; SMOKE N SOUND ACOUSTICAL SEALANT. E. USG CORPORATION; SHEETROCK ACOUSTICAL SEALANT. 2. ACOUSTICAL JOINT SEALANT SHALL HAVE A VOC CONTENT OF LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1168, ADHESIVES AND SEALANTS, AMENDED JANUARY 7, 2005. 2.6 FASTENERS: A. FASTENERS FOR METAL FRAMING, CORROSION-RESISTANT: 1. FOR FASTENING FRAMING MEMBERS TO CONCRETE SURFACES: FASTENERS SHALL BE BEADED DRIVE PINS OR THREADED STUDS DRIVEN BY POWER ACTUATED TOOLS. FASTENERS SHALL RESIST DESIGN LOADS IN ACCORD WITH REQUIREMENTS OF ASTM E1190-11. 2. FOR FASTENING TO METAL DECKING AND FOR FASTENING FRAMING MEMBERS TOGETHER: TYPE S, PAN HEAD SCREWS, IN SIZES RECOMMENDED BY GYPSUM BOARD MANUFACTURER FOR APPLICATIONS INDICATED. 3. PROVIDE SLOTTED, STAND-OFF WASHERS FOR SLIP JOINT ATTACHMENTS. 4. REFER TO DETAILS INDICATED IN DRAWINGS. B. SCREWS FOR GYPSUM BOARD AND ACCESSORY APPLICATION: MEETING ASTM C1002-07, CORROSION-RESISTANT. 1. FOR APPLICATION OF SINGLE LAYER OR BASE LAYER OF GYPSUM BOARD TO METAL FRAMING: 1", TYPE S, BUGLE HEAD. 2. FOR APPLICATION OF FACE LAYER OF GYPSUM BOARD TO METAL FRAMING IN DOUBLE LAYER CONSTRUCTION: 1-5/8", TYPE S, BUGLE HEAD. 3. FOR GYPSUM BOARD TO GYPSUM BOARD APPLICATION: 1-1/2", TYPE G, BUGLE HEAD. C. SCREWS FOR GLASS MAT FACED BOARD APPLICATION: CORROSSION RESISTANT SHEET METAL SCREWS WITH HEAD DIAMETER PROVIDING 125 LB. FASTENER PULL-THROUGH AND PULL-OUT RESISTANCE. SCREW LENGTH SHALL PROVIDE 1/4" MINIMUM THREAD ENGAGEMENT. R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:23:25 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) G0-03 SPECIFICATIONS CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 SECTION 095113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATION SECTIONS, APPLY TO THIS SECTION. 1.2 SUMMARY A. SECTION INCLUDES ACOUSTICAL PANELS AND EXPOSED SUSPENSION SYSTEMS FOR INTERIOR CEILINGS. B. PRODUCTS FURNISHED, BUT NOT INSTALLED UNDER THIS SECTION, INCLUDE ANCHORS, CLIPS, AND OTHER CEILING ATTACHMENT DEVICES TO BE CAST IN CONCRETE. 1.3 ACTION SUBMITTALS A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT. 1.4 DELIVERY, STORAGE, AND HANDLING A. DELIVER ACOUSTICAL PANELS, SUSPENSION-SYSTEM COMPONENTS, AND ACCESSORIES TO PROJECT SITE AND STORE THEM IN A FULLY ENCLOSED, CONDITIONED SPACE WHERE THEY WILL BE PROTECTED AGAINST DAMAGE FROM MOISTURE, HUMIDITY, TEMPERATURE EXTREMES, DIRECT SUNLIGHT, SURFACE CONTAMINATION, AND OTHER CAUSES. B. BEFORE INSTALLING ACOUSTICAL PANELS, PERMIT THEM TO REACH ROOM TEMPERATURE AND A STABILIZED MOISTURE CONTENT. 1.5 FIELD CONDITIONS A. ENVIRONMENTAL LIMITATIONS: DO NOT INSTALL ACOUSTICAL PANEL CEILINGS UNTIL SPACES ARE ENCLOSED AND WEATHERTIGHT, WET-WORK IN SPACES IS COMPLETE AND DRY, WORK ABOVE CEILINGS IS COMPLETE, AND AMBIENT TEMPERATURE AND HUMIDITY CONDITIONS ARE MAINTAINED AT THE LEVELS INDICATED FOR PROJECT WHEN OCCUPIED FOR ITS INTENDED USE. 1. PRESSURIZED PLENUMS: OPERATE VENTILATION SYSTEM FOR NOT LESS THAN 48 HOURS BEFORE BEGINNING ACOUSTICAL PANEL CEILING INSTALLATION. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. SOURCE LIMITATIONS: OBTAIN EACH TYPE OF ACOUSTICAL CEILING PANEL AND ITS SUPPORTING SUSPENSION SYSTEM FROM SINGLE SOURCE FROM SINGLE MANUFACTURER. 2.2 PERFORMANCE REQUIREMENTS A. SURFACE-BURNING CHARACTERISTICS: COMPLY WITH ASTM E 84; TESTING BY A QUALIFIED TESTING AGENCY. IDENTIFY PRODUCTS WITH APPROPRIATE MARKINGS OF APPLICABLE TESTING AGENCY. 1. FLAME-SPREAD INDEX: CLASS B ACCORDING TO ASTM E 1264. 2. SMOKE-DEVELOPED INDEX: 450 OR LESS. B. FIRE-RESISTANCE RATINGS: COMPLY WITH ASTM E 119; TESTING BY A QUALIFIED TESTING AGENCY. IDENTIFY PRODUCTS WITH APPROPRIATE MARKINGS OF APPLICABLE TESTING AGENCY. 1. INDICATE DESIGN DESIGNATIONS FROM UL OR FROM THE LISTINGS OF ANOTHER QUALIFIED TESTING AGENCY. 2.3 ACOUSTICAL PANELS A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. ARMSTRONG WORLD INDUSTRIES, INC. 2. OR EQUAL B. REFER TO FINISH SCHEDULE 2.4 METAL SUSPENSION SYSTEM A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. ARMSTRONG WORLD INDUSTRIES, INC. 2. OR EQUAL B. METAL SUSPENSION-SYSTEM STANDARD: PROVIDE MANUFACTURER'S STANDARD, DIRECT-HUNG, METAL SUSPENSION SYSTEM AND ACCESSORIES ACCORDING TO ASTM C 635/C 635M AND DESIGNATED BY TYPE, STRUCTURAL CLASSIFICATION, AND FINISH INDICATED. C. WIDE-FACE, CAPPED, DOUBLE-WEB ALUMINUM SUSPENSION SYSTEM: MAIN AND CROSS RUNNERS ROLL FORMED FROM ALUMINUM SHEET; PREPAINTED, WITH PREFINISHED 15/16-INCH- WIDE ALUMINUM CAPS ON FLANGES. 1. STRUCTURAL CLASSIFICATION: HEAVY-DUTY SYSTEM. 2. END CONDITION OF CROSS RUNNERS: BUTT-EDGE TYPE. 3. FACE DESIGN: FLAT, FLUSH. 4. CAP MATERIAL: ALUMINUM. 5. CAP FINISH: PAINTED WHITE. 2.5 ACCESSORIES A. ATTACHMENT DEVICES: SIZE FOR FIVE TIMES THE DESIGN LOAD INDICATED IN ASTM C 635/C 635M, TABLE 1, "DIRECT HUNG," UNLESS OTHERWISE INDICATED. COMPLY WITH SEISMIC DESIGN REQUIREMENTS. B. WIRE HANGERS, BRACES, AND TIES: PROVIDE WIRES AS FOLLOWS: 1. STAINLESS-STEEL WIRE: ASTM A 580/A 580M, TYPE 304, NONMAGNETIC, AT KITCHENS AND LAUNDRY. 2. SIZE: WIRE DIAMETER SUFFICIENT FOR ITS STRESS AT THREE TIMES HANGER DESIGN LOAD (ASTM C 635/C 635M, TABLE 1, "DIRECT HUNG") WILL BE LESS THAN YIELD STRESS OF WIRE, BUT NOT LESS THAN 0.135-INCH- DIAMETER WIRE. C. HANGER RODS: MILD STEEL, ZINC COATED OR PROTECTED WITH RUST-INHIBITIVE PAINT. D. ANGLE HANGERS: ANGLES WITH LEGS NOT LESS THAN 7/8 INCH WIDE; FORMED WITH 0.04-INCH- THICK, GALVANIZED-STEEL SHEET COMPLYING WITH ASTM A 653/A 653M, G90 COATING DESIGNATION; WITH BOLTED CONNECTIONS AND 5/16-INCH- DIAMETER BOLTS. 2.6 METAL EDGE MOLDINGS AND TRIM A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. ARMSTRONG WORLD INDUSTRIES, INC. 2. OR EQUAL B. ROLL-FORMED, SHEET-METAL EDGE MOLDINGS AND TRIM: TYPE AND PROFILE INDICATED OR, IF NOT INDICATED, MANUFACTURER'S STANDARD MOLDINGS FOR EDGES AND PENETRATIONS THAT COMPLY WITH SEISMIC DESIGN REQUIREMENTS; FORMED FROM SHEET METAL OF SAME MATERIAL, FINISH, AND COLOR AS THAT USED FOR EXPOSED FLANGES OF SUSPENSION-SYSTEM RUNNERS. 1. EDGE MOLDINGS SHALL FIT ACOUSTICAL PANEL EDGE DETAILS AND SUSPENSION SYSTEMS INDICATED AND MATCH WIDTH AND CONFIGURATION OF EXPOSED RUNNERS UNLESS OTHERWISE INDICATED. 2. FOR LAY-IN PANELS WITH REVEAL EDGE DETAILS, PROVIDE STEPPED EDGE MOLDING THAT FORMS REVEAL OF SAME DEPTH AND WIDTH AS THAT FORMED BETWEEN EDGE OF PANEL AND FLANGE AT EXPOSED SUSPENSION MEMBER. 3. FOR CIRCULAR PENETRATIONS OF CEILING, PROVIDE EDGE MOLDINGS FABRICATED TO DIAMETER REQUIRED TO FIT PENETRATION EXACTLY. PART 3 - EXECUTION 3.1 EXAMINATION A. EXAMINE SUBSTRATES, AREAS, AND CONDITIONS, INCLUDING STRUCTURAL FRAMING TO WHICH ACOUSTICAL PANEL CEILINGS ATTACH OR ABUT, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH REQUIREMENTS SPECIFIED IN THIS AND OTHER SECTIONS THAT AFFECT CEILING INSTALLATION AND ANCHORAGE AND WITH REQUIREMENTS FOR INSTALLATION TOLERANCES AND OTHER CONDITIONS AFFECTING PERFORMANCE OF ACOUSTICAL PANEL CEILINGS. B. EXAMINE ACOUSTICAL PANELS BEFORE INSTALLATION. REJECT ACOUSTICAL PANELS THAT ARE WET, MOISTURE DAMAGED, OR MOLD DAMAGED. C. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 3.2 PREPARATION A. MEASURE EACH CEILING AREA AND ESTABLISH LAYOUT OF ACOUSTICAL PANELS TO BALANCE BORDER WIDTHS AT OPPOSITE EDGES OF EACH CEILING. AVOID USING LESS-THAN-HALF-WIDTH PANELS AT BORDERS UNLESS OTHERWISE INDICATED, AND COMPLY WITH LAYOUT SHOWN ON REFLECTED CEILING PLANS. B. LAYOUT OPENINGS FOR PENETRATIONS CENTERED ON THE PENETRATING ITEMS. 3.3 INSTALLATION A. INSTALL ACOUSTICAL PANEL CEILINGS ACCORDING TO ASTM C 636/C 636M, AND MANUFACTURER'S WRITTEN INSTRUCTIONS. 1. FIRE-RATED ASSEMBLY: INSTALL FIRE-RATED CEILING SYSTEMS ACCORDING TO TESTED FIRE-RATED DESIGN. B. SUSPEND CEILING HANGERS FROM BUILDING'S STRUCTURAL MEMBERS AND AS FOLLOWS: 1. INSTALL HANGERS PLUMB AND FREE FROM CONTACT WITH INSULATION OR OTHER OBJECTS WITHIN CEILING PLENUM THAT ARE NOT PART OF SUPPORTING STRUCTURE OR OF CEILING SUSPENSION SYSTEM. 2. SPLAY HANGERS ONLY WHERE REQUIRED AND, IF PERMITTED WITH FIRE-RESISTANCE-RATED CEILINGS,TO MISS OBSTRUCTIONS; OFFSET RESULTING HORIZONTAL FORCES BY BRACING, COUNTERSPLAYING, OR OTHER EQUALLY EFFECTIVE MEANS. 3. WHERE WIDTH OF DUCTS AND OTHER CONSTRUCTION WITHIN CEILING PLENUM PRODUCES HANGER SPACINGS THAT INTERFERE WITH LOCATION OF HANGERS AT SPACINGS REQUIRED TO SUPPORT STANDARD SUSPENSION-SYSTEM MEMBERS, INSTALL SUPPLEMENTAL SUSPENSION MEMBERS AND HANGERS IN FORM OF TRAPEZES OR EQUIVALENT DEVICES. 4. SECURE WIRE HANGERS TO CEILING-SUSPENSION MEMBERS AND TO SUPPORTS ABOVE WITH A MINIMUM OF THREE TIGHT TURNS. CONNECT HANGERS DIRECTLY TO STRUCTURE OR TO INSERTS, EYE SCREWS, OR OTHER DEVICES THAT ARE SECURE AND APPROPRIATE FOR SUBSTRATE AND THAT WILL NOT DETERIORATE OR OTHERWISE FAIL DUE TO AGE, CORROSION, OR ELEVATED TEMPERATURES. 5. SECURE FLAT, ANGLE, CHANNEL, AND ROD HANGERS TO STRUCTURE, INCLUDING INTERMEDIATE FRAMING MEMBERS, BY ATTACHING TO INSERTS, EYE SCREWS, OR OTHER DEVICES THAT ARE SECURE AND APPROPRIATE FOR BOTH THE STRUCTURE TO WHICH HANGERS ARE ATTACHED AND THE TYPE OF HANGER INVOLVED. INSTALL HANGERS IN A MANNER THAT WILL NOT CAUSE THEM TO DETERIORATE OR FAIL DUE TO AGE, CORROSION, OR ELEVATED TEMPERATURES. 6. DO NOT SUPPORT CEILINGS DIRECTLY FROM PERMANENT METAL FORMS OR FLOORDECK. FASTEN HANGERS TO CAST-IN-PLACE HANGER INSERTS, POST- INSTALLED MECHANICAL OR ADHESIVE ANCHORS, OR POWER-ACTUATED FASTENERS THATEXTENDTHROUGH FORMS INTO CONCRETE. 7. WHEN STEEL FRAMING DOES NOT PERMIT INSTALLATION OF HANGER WIRES AT SPACING REQUIRED, INSTALL CARRYING CHANNELS OR OTHER SUPPLEMENTAL SUPPORT FOR ATTACHMENT OF HANGER WIRES. 8. DO NOT ATTACH HANGERS TO STEEL DECK TABS. 9. DO NOT ATTACH HANGERS TO STEEL ROOF DECK. ATTACH HANGERS TO STRUCTURALMEMBERS. 10. SPACE HANGERS NOT MORE THAN 48 INCHES O.C. ALONG EACH MEMBER SUPPORTED DIRECTLY FROM HANGERS UNLESS OTHERWISE INDICATED; PROVIDE HANGERS NOT MORE THAN 8 INCHES FROM ENDS OF EACH MEMBER. 11. SIZE SUPPLEMENTAL SUSPENSION MEMBERS AND HANGERS TO SUPPORT CEILING LOADS WITHIN PERFORMANCE LIMITS ESTABLISHED BY REFERENCED STANDARDS. C. SECURE BRACING WIRES TO CEILING SUSPENSION MEMBERS AND TO SUPPORTS WITH A MINIMUM OF FOUR TIGHT TURNS. SUSPEND BRACING FROM BUILDING'S STRUCTURAL MEMBERS AS REQUIRED FOR HANGERS, WITHOUT ATTACHING TO PERMANENT METAL FORMS, STEEL DECK, OR STEEL DECK TABS. FASTEN BRACING WIRES INTO CONCRETE WITH CAST-IN-PLACE OR POSTINSTALLED ANCHORS. D. INSTALL EDGE MOLDINGS AND TRIM OF TYPE INDICATED AT PERIMETER OF ACOUSTICAL CEILING AREA AND WHERE NECESSARY TO CONCEAL EDGES OF ACOUSTICAL PANELS. 1. APPLY ACOUSTICAL SEALANT IN A CONTINUOUS RIBBON CONCEALED ON BACK OF VERTICAL LEGS OF MOLDINGS BEFORE THEY ARE INSTALLED. 2. SCREW ATTACH MOLDINGS TO SUBSTRATE AT INTERVALS NOT MORE THAN 16 INCHES O.C. AND NOT MORE THAN 3 INCHES FROM ENDS. MITER CORNERS ACCURATELY AND CONNECT SECURELY. 3. DO NOT USE EXPOSED FASTENERS, INCLUDING POP RIVETS, ON MOLDINGS AND TRIM. E. INSTALL SUSPENSION-SYSTEM RUNNERS SO THEY ARE SQUARE AND SECURELY INTERLOCKED WITH ONE ANOTHER. REMOVE AND REPLACE DENTED, BENT, OR KINKED MEMBERS. F. INSTALL ACOUSTICAL PANELS WITH UNDAMAGED EDGES AND FIT ACCURATELY INTO SUSPENSION-SYSTEM RUNNERS AND EDGE MOLDINGS. SCRIBE AND CUT PANELS AT BORDERS AND PENETRATIONS TO PROVIDE PRECISE FIT. 1. ARRANGE DIRECTIONALLY PATTERNED ACOUSTICAL PANELS AS FOLLOWS: A. INSTALL PANELS WITH PATTERN RUNNING IN ONE DIRECTION PARALLEL TO SHORT AXIS OF SPACE. 2. FOR SQUARE-EDGED PANELS, INSTALL PANELS WITH EDGES FULLY HIDDEN FROM VIEW BY FLANGES OF SUSPENSION-SYSTEM RUNNERS AND MOLDINGS. 3. FOR REVEAL-EDGED PANELS ON SUSPENSION-SYSTEM RUNNERS, INSTALL PANELS WITH BOTTOM OF REVEAL IN FIRM CONTACT WITH TOP SURFACE OF RUNNER FLANGES. 4. FOR REVEAL-EDGED PANELS ON SUSPENSION-SYSTEM MEMBERS WITH BOX-SHAPED FLANGES, INSTALL PANELS WITH REVEAL SURFACES IN FIRM CONTACT WITH SUSPENSION-SYSTEM SURFACES AND PANEL FACES FLUSH WITH BOTTOM FACE OF RUNNERS. 5. PAINT CUT EDGES OF PANEL REMAINING EXPOSED AFTER INSTALLATION; MATCH COLOR OF EXPOSED PANEL SURFACES USING COATING RECOMMENDED IN WRITING FOR THIS PURPOSE BY ACOUSTICAL PANEL MANUFACTURER. 6. INSTALL HOLD-DOWN AND IMPACT CLIPS IN AREAS INDICATED; SPACE ACCORDING TO PANEL MANUFACTURER'S WRITTEN INSTRUCTIONS UNLESS OTHERWISE INDICATED. A. HOLD-DOWN CLIPS: SPACE 24 INCHES O.C. ON ALL CROSS RUNNERS. 7. PROTECT LIGHTING FIXTURES AND AIR DUCTS ACCORDING TO REQUIREMENTS INDICATED FOR FIRE-RESISTANCE-RATED ASSEMBLY. 3.4 ERECTION TOLERANCES A. SUSPENDED CEILINGS: INSTALL MAIN AND CROSS RUNNERS LEVEL TO A TOLERANCE OF 1/8 INCH IN 12 FEET, NON-CUMULATIVE. B. MOLDINGS AND TRIM: INSTALL MOLDINGS AND TRIM TO SUBSTRATE AND LEVEL WITH CEILING SUSPENSION SYSTEM TO A TOLERANCE OF 1/8 INCH IN 12 FEET, NON- CUMULATIVE. 3.5 FIELD QUALITY CONTROL A. SPECIAL INSPECTIONS: OWNER WILL ENGAGE A QUALIFIED SPECIAL INSPECTOR TO PERFORM THE FOLLOWING SPECIAL INSPECTIONS: 1. PERIODIC INSPECTION DURING THE INSTALLATION OF SUSPENDED CEILING GRIDS ACCORDING TO ASCE/SEI 7. B. TESTING AGENCY: OWNER WILL ENGAGE A QUALIFIED TESTING AGENCY TO PERFORM TESTS AND INSPECTIONS. C. PERFORM THE FOLLOWING TESTS AND INSPECTIONS OF COMPLETED INSTALLATIONS OF ACOUSTICAL PANEL CEILING HANGERS AND ANCHORS AND FASTENERS IN SUCCESSIVE STAGES AND WHEN INSTALLATION OF CEILING SUSPENSION SYSTEMS ON EACH FLOOR HAS REACHED 20 PERCENT COMPLETION, BUT NO PANELS HAVE BEEN INSTALLED. DO NOT PROCEED WITH INSTALLATIONS OF ACOUSTICAL PANEL CEILING HANGERS FOR THE NEXT AREA UNTIL TEST RESULTS FOR PREVIOUSLY COMPLETED INSTALLATIONS OF ACOUSTICAL PANEL CEILING HANGERS SHOW COMPLIANCE WITH REQUIREMENTS. 1. WITHIN EACH TEST AREA, TESTING AGENCY WILL SELECT ONE OF EVERY 10 POWER-ACTUATED FASTENERS AND POSTINSTALLED ANCHORS USED TO ATTACH HANGERS TO CONCRETE AND WILL TEST THEM FOR 200 LBF OF TENSION; IT WILL ALSO SELECT ONE OF EVERY TWO POSTINSTALLED ANCHORS USED TO ATTACH BRACING WIRES TO CONCRETE AND WILL TEST THEM FOR 440 LBF OF TENSION. 2. WHEN TESTING DISCOVERS FASTENERS AND ANCHORS THAT DO NOT COMPLY WITH REQUIREMENTS, TESTING AGENCY WILL TEST THOSE ANCHORS NOT PREVIOUSLY TESTED UNTIL 20 PASS CONSECUTIVELY AND THEN WILL RESUME INITIAL TESTING FREQUENCY. D. PREPARE TEST AND INSPECTION REPORTS. 3.6 CLEANING A. CLEAN EXPOSED SURFACES OF ACOUSTICAL PANEL CEILINGS, INCLUDING TRIM, EDGE MOLDINGS, AND SUSPENSION-SYSTEM MEMBERS. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR CLEANING AND TOUCHUP OF MINOR FINISH DAMAGE. B. REMOVE AND REPLACE CEILING COMPONENTS THAT CANNOT BE SUCCESSFULLY CLEANED AND REPAIRED TO PERMANENTLY ELIMINATE EVIDENCE OF DAMAGE. SECTION 09 6500 - RESILIENT FLOORING PART 1 - GENERAL 1.1 ACTION SUBMITTALS: A. PRODUCT DATA: INDICATE PRODUCT CHARACTERISTICS AND INSTALLATION REQUIREMENTS, INCLUDING MANUFACTURER'S RECOMMENDED ADHESIVES AND MAINTENANCE INSTRUCTIONS. B. SAMPLES: SUBMIT FULL SIZE SAMPLES FOR EACH TYPE COLOR AND PATTERN OF FLORRING AND ACCESSORY REQUIRED. 1.2 QUALITY ASSURANCE: A. APPLICABLE STANDARDS, AS REFERENCED HEREIN: ASTM INTERNATIONAL (ASTM). 1.3 PROJECT/SITE CONDITIONS: A. ENVIRONMENTAL REQUIREMENTS: 1. MAINTAIN TEMPERATURE IN SPACE TO RECEIVE RESILIENT MATERIALS AT NOT LESS THAN 70 DEGREES F. FOR NOT LESS THAN 24 HOURS BEFORE, DURING AND FOR 48 HOURS AFTER INSTALLATION. 2. MAINTAIN MINIMUM TEMPERATURE OF 55 DEGREES F. AFTER FLOORING IS INSTALLED, EXCEPT AS SPECIFIED ABOVE, FOR DURATION OF PROJECT. B. DELIVER VINYL FLOORING AND BASE PRODUCTS TO JOBSITE A MINIMUM OF 24 HOURS PRIOR TO USE. UNROLL VINYL BASE AND LOW PERCENTAGE RUBBER AND ALLOW TO RELAX FOR 24 HOURS PRIOR TO USING. C. PROTECTION: PROTECT FINISHED FLOORING, BASE AND ACCESSORIES FROM STAINING, MARRING OR OTHER PHYSICAL DAMAGE BY WORK OF OTHER TRADES. COVER OR MASK SURFACES AS REQUIRED. PART 2 - PRODUCTS 2.1 RUBBER BASE: A. ACCEPTABLE MANUFACTURERS: 1. BASIS OF DESIGN; JOHNSONITE, INC. 2. ROPPE CORP. 3. BURKE FLOORING, A DIV. OF BURKE INDUSTRIES B. CHARACTERISTICS: 1. TYPE: MINIMUM 48% RUBBER, 100% VULCANIZED; MEETING ASTM F1861-08(2012), TYPE TS THERMOSET VULCANIZED RUBBER SBR. 2. LENGTH: MINIMUM 120'-0" ROLLS. 3. THICKNESS: 1/8". 4. HEIGHT: 4"; TOP SET COVE BASE. 5. STYLE AND COLOR: AS INDICATED IN FINISH SCHEDULE IN DRAWINGS. 2.2 SHEET FLOORING WITH BACKING: A. ACCEPTABLE MANUFACTURERS: 1. NORA SYSTEMS. 2. ARMSTRONG WORLD INDUSTRIES, INC. 3. SHAW CONTRACT. 4. TARKETT. B. TYPE: MEETING ASTM F1303-04(2009). 1. TYPE: HETEROGENEOUS, TYPE I, GRADE 1 2. WEAR-LAYER THICKNESS: 0.022 IN. 3. OVERALL THICKNESS: 0.080 IN. 4. BACKING CLASS: CLASS A. 5. FINISH: UV-CURED POLYURETHANE. 6. SIZE: 6 FT. X 82 FT. 7. COLORS AND PATTERNS: AS INDICATED IN FINISH SCHEDULE IN DRAWINGS. C. FIRE RESISTANCE: CRITICAL RADIENT FLUX MEETING CLASS I, 0.45 WATTS/CM^2 WHEN TESTED IN ACCORD WITH ASTM E648-10. SMOKE DEVELOPMENT OF 450 OR LESS WHEN TESTED IN ACCORD WITH ASTM E662-12. 2.3 ACCESSORIES: A. ACCEPTABLE MANUFACTURERS: 1. BURKE FLOORING PRODUCTS, A DIV. OF BURKE INDUSTRIES. 2. MARLEY FLEXCO (USA), INC. 3. JOHNSONITE, INC. 4. R. C. MUSSON RUBBER CO. 5. ROPPE CORP. B. REDUCERS: 1. MATERIAL: RUBBER 2. THICKNESS: SAME AS ABUTTING FLOOR MATERIALS. 3. WIDTH(S): 1", UNLESS INDICARTED OTHERWISE. 4. EDGES: TAPERED. 5. COLORS: SUBMIT SAMPLE FOR ARCHITECT'S APPROVAL 2.4 INSTALLATION MATERIALS: A. LEVELING COMPOUND: ACCEPTABLE PRODUCTS: AS SPECIFIED IN SECTION 03 8215. B. ADHESIVES: WATER-RESISTANT TYPES AND BRANDS OF ADHESIVE RECOMMENDED BY FLOORING MATERIAL MANUFACTURER'S PRODUCT DATA FOR INSTALLATION CONDITIONS INDICATED. 1. VOC CONTENT: ADHESIVES SHALL HAVE A VOC CONTENT LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1113, ARCHITECTURAL COATINGS, RULES IN EFFECT JANUARY 1, 2004. C. CHEMICAL-BONDING COMPOUND: MANUFACTURER'S PRODUCT FOR CHEMICALLY BONDING SEAMS. 1. VOC CONTENT: VOC CONTENT LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1113, ARCHITECTURAL COATINGS, RULES IN EFFECT JANUARY 1, 2004. PART 3 - EXECUTION 3.1 PREPARATION: A. PREPARE SURFACES TO RECEIVE RESILIENT MATERIAL IN ACCORD WITH FLOORING MANUFACTURER'S INSTRUCTIONS. B. GRIND HIGH AREAS AND FILL DEPRESSIONS WITH LEVELING COMPOUND WHERE REQUIRED TO PRODUCE SMOOTH INSTALLATION AND FOR PROPER ALIGNMENT OF RESILIENT FLOORING WITH ADJACENT FLOORING MATERIALS. C. PERFORM BOND AND MOISTURE TESTS ON SUBFLOORS IN ACCORD WITH ASTM F2170-11 AND RESILIENT FLOORING MANUFACTURER'S PRODUCT DATA, TO DETERMINE IF SURFACES ARE ACCEPTABLE TO RECEIVE SPECIFIED RESILIENT FLOORING PRODUCTS. CORRECT CONDITIONS DETRIMENTAL TO RESILIENT FLOORING INSTALLATION PRIOR TO STARTING INSTALLATION. D. REMOVE DIRT, OIL, GREASE OR OTHER FOREIGN MATTER FROM SURFACES TO RECEIVE FLOOR COVERING OR ACCESSORIES. 3.2 APPLICATION OF ADHESIVES: A. MIX AND APPLY ADHESIVES IN ACCORD WITH RESILIENT MATERIAL MANUFACTURER'S PRODUCT DATA. APPLY WITH NOTCHED TROWEL OR OTHER TOOLS AS RECOMMENDED BY ADHESIVE MANUFACTURER. 2.7 JOINT MATERIALS AND ADHESIVES: A. STANDARD GYPSUM BOARD PRODUCTS: 1. JOINT TAPE: MEETING ASTM C475-12, PERFORATED PAPER TYPE. 2. JOINT COMPOUND: MEETING ASTM C475-12, READY-MIXED TAPE EMBEDMENT AND TOPPING COMPOUNDS, VINYL-BASED. B. MOLD AND MOISTURE RESISTANT PAPER FACED GYPSUM BOARD: JOINT TAPE AND JOINT COMPOUND SHALL BE IN ACCORD WITH RECOMMENDATIONS OF BOARD MANUFACTURER'S PRODUCT DATA. C. JOINT TAPE FOR GLASS MAT-FACED BOARD: FIBERGLASS TAPE, AS HEREIN SPECIFIED. 2.8 ACCESSORIES: A. ACCESSORIES SHALL COMPLY WITH ASTM C1047-10A B. CORNER REINFORCEMENT: VINYL CORP., "RIGID VINYL DRYWALL & VENEER ACCESSORIES, MODEL CBD125 CORNER BEADS"; LEAD-FREE, VIRGIN VINYL COMPOUNDS CORNER BEADS WITH 1-1/4" X 1-1/4" PERFORATED FLANGES. C. METAL JAMB, CEILING AND CASING TRIM: MANUFACTURER'S STANDARD "L" AND "U" SHAPED GALVANIZED MEMBERS WITH FINE EXPANDED MESH FLANGES; "MUD-IN" TYPE FOR FINISHING WITH JOINT COMPOUNDS. D. TIE WIRE: MINIMUM 18 GA. GALVANIZED, ANNEALED STEEL WIRE. E. SPECIAL TRIM SHAPES: 1. ACCEPTABLE MANUFACTURERS; SUBJECT TO COMPLIANCE WITH SPECIFIED REQUIREMENTS: A. FRY REGLET CORP. B. GORDON, INC. C. PITTCON INDUSTRIES, INC. 2. CHARACTERISTICS: A. MATERIAL: MANUFACTURER'S STANDARD ALUMINUM ALLOW. B. FINISH: PAINTED FINISH, COLOR SELECTED BY ARCHITECT. C. SHAPES: AS INDICATED ON DRAWINGS. PART 3 - EXECUTION 3.1 FRAMING AND FURRING INSTALLATION: A. EXCEPT WHERE STRINGENT REQUIREMENTS ARE SPECIFIED, INSTALL FRAMING AND FURRING IN ACCORD WITH ASTM C754-11, GYPSUM ASSOCIATION REQUIREMENTS AND MANUFACTURER'S PRODUCT DATA. B. RUNNERS: 1. ATTACH RUNNER TRACKS AT FLOOR AND UNDERSIDE OF STRUCTURAL DECK WITH SPECIFIED FASTENERS. PROVIDE SLIP JOINT ATTACHMENTS TO MEET DEFLECTION CRITERIA AND MANUFACTURER'S CALCULATIONS AT THE FOLLOWING LOCATIONS: A. TALL PARTITIONS. B. FULL-HEIGHT, FLOOR-TO-FLOOR OR FLOOR-TO-DECK PARTITIONS. C. ALL PARTITIONS SUBJECT TO DEFLECTION. 2. WHERE PARTITIONS ARE INDICATED TO STOP AT FINISH CEILING, ATTACH TO CEILING SUSPENSION SYSTEM USING 1/8" TOGGLE BOLTS OR SHEET METAL SCREWS SPACED AT 1'-4" O.C., MAXIMUM, WHERE PARTITION ALIGNS WITH CEILING GRID. WHERE PARTITION DOES NOT ALIGN WITH GRID, ATTACH AT EACH INTERSECTION WITH GRID. C. STUDS: 1. POSITION FULL LENGTH STUDS VERTICALLY, ENGAGING FLOOR AND CEILING RUNNERS. A. SPACE STUDS AS INDICATED ON DRAWINGS. B. SPACE STUDS NOT TO EXXCEED 1'-4" O.C. FOR PARTITIONS TO FRP PANELS. 2. PROVIDE JUMBO STUDS AT INTERIOR AND EXTERIOR CORNERS, PARTITION TERMINATION AND ADJACENT TO DOOR AND BORROWED LITE OPENINGS IN PARTITIONS. 3. SECURE ABUTTING AND INTERSECTING WALLS WITH FASTENERS THROUGH STUD FLANGES. 4. FOR HORIZONTAL REINFORCEMENT AT DOOR AND BORROWED LITE FRAMES, INSTALL CUT-TO-LENTH RUNNER SECTIONS WITH SLIT FLANGES SECURED TO STUDS. 5. INSTALL ACOUSTICAL TAPE ON METAL STUDS WHICH ABUT OTHER STUDS OR DISSIMILAR SURFACES IN WALLS TO RECEIVE SOUND ATTENUATION BLANKETS. D. AT LOCATIONS OF ATTACHMENTS TO METAL-FRAMED GYPSUM BOARD PARTITIONS, PROVIDE MINIMUM 16GA. STEEL PLATE FOR ATTACHMENT. ATTACH TO METAL FRAMING AS INDIACTED ON DRAWINGS. 3.2 GENERAL BOARD APPLICATION: A. EXCEPT WHERE MORE STRINGENT REQUIREMENT ARE SPECIFIED, INSTALL GYPSUM BOARD IN ACCORD WITH ASTM C840-11, GA-216 AND MANUFACTURER'S PRODUCT DATA. B. INSTALL CEILING PANELS ACROSS FRAMING TO MINIMIZE THE NUMBER OF ABUTTING END JOINTS AND TO AVOID ABUTTING END JOINTS IN CENTRAL AREA OF EACH CEILING. STAGGER ABUTTING END JOINTS OF ADJACENT PANELS NOT LESS THAN ONE FRAMING MEMBER. C. USE GYPSUM BOARD OF MAXIMUM LENGTHS TO MINIMIZE END JOINTS. STAGGER END JOINTS. D. ABUT GYPSUM BOARDS WITHOUT FORCING. FIT ENDS AND EDGES OF BOARD. DO NOT PLACE BUTT ENDS AGAINST TAPERED EDGES. E. SUPPORT ENDS AND EDGES OF GYPSUM BOARD PANELS ON FRAMING OR FURRING MEMBERS, EXCEPT FOR FACE LAYER OF DOUBLE LAYER WORK. F. INSTALL GYPSUM BOARD ACCESSORIES IN ACCORD WITH GYPSUM BOARD MANUFACTURER'S PRODUCT DATA AND AS FOLLOWS: 1. CORNER BEAD: INSTALL VINYL CORNER BEADS AT EXTERNAL CORNERS. 2. METAL TRIM SHAPES: AT EXPOSED EDGE OF GYPSUM BOARD AT DOOR AND WINDOW OPENINGS, AT INTERSECTIONS WITH OTHER MATERIALS AND AT INTERSECTION OF WALLS WITH CEILINGS. 3. INSTALL CORNER BEADS AND METAL TRIM SHAPES TO FRAMING SYSTEM WITH MECHANICAL ANCHORS. G. INSTALL ACOUSTICAL SEALANT AT SOUND-RATED PARTITIONS: 1. SEAL PARTITION PERIMETER WITH CONTINUOUS 1/4" MINIMUM ROUND BEAD OF ACOUSTICAL SEALANT APPLIED TO EACH LEG OF RUNNERS, INCLUDING THOSE USED AT PARTITION INTERSECTIONS WITH DISSIMILAR WALL CONSTRUCTION. 2. INSTALL GYPSUM BOARD WITH 1/8" PERIMETER RELIEF COMPRESSING SEALANT TO FORM PERMANENT AIRTIGHT SEAL. 3. WHERE SLIP JOINT ATTACHMENTS ARE REQUIRED AT TOP OF PARTITIONS, FILL RESULTING JOINT BETWEEN DRYWALL AND ADJACENT STRUCTURE WITH ACOUSTICAL SEALANT TO FORM PERMANENT AIR TIGHT SEAL. 4. APPLY ACOUSTICAL SEALANT AROUND CUTOUTS SUCH AS AT ELECTRICAL BOXES, PLUMBING PENETRATIONS, MEDICINE CABINETS, HEATING DUCTS AND COLD AIR RETURNS TO FORM PERMANENT AIRTIGHT SEAL. (SEALANT SHALL NOT BE USED AS A FIRE STOPPING MATERIAL.) H. INSTALL MOLD-MOISTURE RESISTANT GYPSUM BOARD IN DAMP, MOIST LOCATIONS. I. CONTINUE REQUIRED COMPONENTS OF FIRE-RATED AND ACOUSTICALLY RATED WALL ASSEMBLY TO OVERHEAD STRUCTURE. APPLY JOINT TAPE AND ONE COAT OF COMPOUND TO GYPSUM BOARD JOINTS CONCEALED FROM VIEW IN COMPLETED WORK. J. IDENTIFICATION: 1. FIRE, WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. 2. SUCH IDENTIFICATION SHALL BE ABOVE ANY DECORATIVE CEILING AND IN CONCEALED SPACES. 3. SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS: "_____ HOUR FIRE AND SMOKE BARRIER - PROTECT ALL OPENINGS." K. ALLOWABLE TOLERANCES IN FRAMED GYPSUM BOARD CONSTRUTION. 1. POSITION: + - 1/4" MAXIMUM VARIATION FROM DESIGN POSITIOIN. 2. ALIGNMENT: 1/8" IN 8'-0"; 1/4" MAXIMUM IN ANY CONTINOUS WALL, LINE OR SURFACE. 3. SURFACE PLANE: 1/8" IN 12-0"; 1/16" IN 1'-0", MAXIMUM VARIATION IN TRUE SURFACE PLANE. 4. SURFACE SMOOTHNESS: NO JOINT OR FASTENER LOCATION, ROUGHNESS OR BLEMISH DISCERNIBLE AFTER APPLICATION OF FINISH WHEN VIEWED AT ANY ANGLE FROM A DISTANCE OF 5'-0" UNDER OCCUPANCY LIGHTING CONDITIONS, WITH SURFACE PREPARATION AS SPECIFIED IN PAINTING AND COATING SECTION. L. ALLOWABLE TOLERANCES IN SUSPENDED GYPSUM BOARD FURRING SYSTEM CEILINGS: 1. DEFLECTION: SUSPENSION SYSTEM COMPONENTS, HANGERS AND FASTENING DEVICES SUPPORTING LIGHTING FIXTURES, CEILING GRILLES AND ACOUSTICAL UNITS SHALL HAVE MAXIMUM DEFLECTION OF 1/360 OF SPAN WHEN TESTED IN ACCORD WITH ASTM C635-07. 2. BOW, CAMBER AND TWIST: NOT EXCEEDING TOLERANCES ESTABLISHED BY ASTM C635-07. 3. VARIATION FROM LEVEL IN FINISHED CEILING: 1/8" IN 12'-0". 4. VARIATION IN PLANE OF ADJACENT GYPSUM BOARD PANELS PRIOR TO JOINT TREATMENT: 1/16". 3.3 SINGLE LAYER APPLICATION: A. CEILING: APPLY GYPSUM BOARD WITH LONG DIMENSION AT RIGHT ANGLES TO FRAMING. TERMINATE EDGES OF GYPSUM BOARD RUNNING PARALLEL TO FRAMING ON FRAMING MEMBERS. B. WALLS: 1. APPLY GYPSUM BOARD VERTICALLY AND HORIZONTALLY AT CONTRACTOR'S OPTION, EXCEPT AS REQUIRED BY GYPSUM BOARD MANUFACTURER'S PRODUCT DATA FOR SYSTEM DESIGNS, INCLUDING FIRE-RATED AND ACOUSTICALLY-RATED PARTITIONS. 2. STAGGER END JOINTS IN OPPOSITE SIDES OF PARTITIONS. 3. TERMINATE EDGES OF GYPSUM BOARD RUNNING PARALLEL TO FRAMING, FURRING ON FRAMING OR FURRING MEMBERS. C. FASTENING: ATTACH GYPSUM BOARD USING FASTENERS SPECIFIED AT SPACING REQUIRED BY MANUFACTURER'S PRODUCT DATA. 3.4 JOINT TREATMENT: A. FINISH LEVELS SHALL BE IN ACCORD WITH THE "RECOMMENDED SPECIFICATON: LEVELS OF GYPSUM BOARD FINISH" AS PUBLISHED JOINTLY BY THE GYPSUM ASSOCIATION, AWCI, CISCA, AND PDCA. B. FINISH LEVEL 1; JOINT TREATMENT FOR NON-PUBLIC, NON-SERVICE AREAS TO RECEIVE NO FURTHER FINISH, INCLUDING STORAGE AREAS: APPLY JOINT COMPOUND TO JOINTS AND ANGLES IN GYPSUM BOARD AND EMBED JOINT TAPE. SURFACE SHALL BE FREE OF EXCESS JOINT COMPOUND; TOOL MARKS AND RIDGES ARE ACCEPTABLE. C. FINISH LEVEL 2; JOINT TREATMENT FOR AREAS INDICATED TO RECEIVE NO FURTHER FINISH; APPLY JOINT COMPOUND TO JOINTS, ANGLES, FASTENER HEADS AND ACCESSORIES. EMBED JOINT TAPE. APPLY ONE ADDITIONAL COAT OR COMPOUND OVER TAPE. APPLY ONE COAT OF COMPOUND TO FASTENER DEPRESSIONS. SURFACES SHALL BE FREE OF EXCESS JOINT COMPOUND; TOOL MARKS AND RIDGES ARE ACCEPTABLE. D. FINISH LEVEL 4; JOINT TREATMENT FOR AREAS INDICATED TO RECEIVE SEMI-GLOSS AND EGGSHELL PAINT FINISHES: 1. APPLY JOINT COMPOUND TO JOINTS, ANGLES, FASTENER HEADS AND ACCESSORIES. EMBED JOINT TAPE. APPLY THREE ADDITIONAL COATS OF COMPOUND OVER TAPE, FEATHEREDGING AND SANDING EACH COAT. 2. APPLY MINIMUM OF THREE COATS OF COMPOUND TO FASTENER DEPRESSIONS, SANDING EACH COAT AND BRINGING TO LEVEL PLANE WITH GYPSUM BOARD SURFACE. 3. ALL JOINT COMPOUND SHALL BE FREE OF TOOL MARKS AND RIDGES. E. FASTENER POP: DRIVE NEW FASTENER APPROXIMATELY 1-1/2" FROM POPPED FASTENER AND REPAIR TO MATCH GYPSUM BOARD FINISH. F. FILL CRACKS WITH JOINT COMPOUND AND SAND SMOOTH AND FLUSH. G. DUST SURFACES AND LEAVE READY FOR DECORATION. JOINT AND FASTENER TREATMENT SHALL BE INDISTINGUISHABLE IN FINISHED WORK. END OF SECTION B. PROVIDE SAFETY PRECAUTIONS DURING MIXING AND APPLICATIONS AS RECOMMENDED BY ADHESIVE MANUFACTURER. C. APPLY ADHESIVE TO ONLY THAT AREA WHICH CAN BE COVERED BY RESILIENT MATERIAL WITHIN THE RECOMMENDED WORKING TIME OF THE ADHESIVE. 1. REMOVE ADHESIVE WHICH DRIES OR FILMS OVER. 2. DO NOT SOIL WALLS, BASES OR ADJACENT AREAS WITH ADHESIVES. 3. REMOVE SPILLED OR MISPLACED MATERIALS. 3.3 INSTALLATION OF VINYL SHEET FLOORING: A. WORKMANSHIP: 1. INSTALL SHEET MATERIAL IN ACCORD WITH RFCI SPECIFICATIONS IS-1 AND WITH FLOORING MANUFACTURER'S PRODUCT DATA. 2. CUT SHEET MATERIAL IN LENGTHS AND SIZES REQUIRED; COMPLY WITH MANUFACTURER'S CUTTIG AND FITTING INSTRUCTIONS. 3. LAY CUT SHEETS FLAT AND ALLOW TO ACCLIMATIZE TO ROOM TEMPERATURE PRIOR TO SECURING IN PLACE. B. APPLY FULL BED OF ADHESIVE UNIFORMLY OVER EXPOSED SUBFLOOR. TURN SHEET BACK INTO WET ADHESIVE. C. WORK OUT WRINKLES AND AIR POCKETS. ROLL MATERIAL IN TWO DIRECTIONS STARTING AT CENTER OF SHEET. 3.4 INSTALLATION OF BASE: A. WORKMANSHIP: 1. UNROLL BASE MATERIAL AND ALLOW TO RELAX FOR 24 HOURS, MINIMUM, PRIOR TO INSTALLATION. CUT INTO LENGTHS FOR MINIMUM NUMBER OF JOINTS. DOUBLE-CUT ADJOINING LENGTHS. 2. INSTALL WITH TIGHT BUTT JOINTS WITH NO JOINT WIDTHS GREATER THAN 1/64". B. TOP-SER BASE: 1. APPLY ADHESIVE AND ADHERE TO VERTICAL SURFACES. 2. PRESS DOWN SO THAT BOTTOM EDGE FOLLOWS FLOOR PROFILE. 3. FORM INTERNAL CORNERS USING PREMOLDED CORNERS. 4. FORM EXTERNAL CORNERS USING PREMOLDED CORNERS. 5. SCRIBE BASE TO ABUTTING MATERIALS. 3.5 ACCESSORY INSTALLATION: A. CUT MATERIALS TO LENGTHS AND SIZES INDICATED. B. RESILIENT REDUCERS: 1. APPLY ADHESIVES AND BOND TO SUBSTRATE. 2. CENTER AND REDUCERS IN DOOR OPENINGS. 3. FIT EDGE TO DOOR FRAME JAMBS WITHOUT VISIBLE GAPS OR CRACKS. 4. FIT EDGES TO ABUTTING FLOOR MATERIALS FOR FLUSH FIT. 3.6 CLEANING: A. UPON COMPLETION OF INSTALLATION, CLEAN SURFACES USING A NEUTRAL CLEANER ACCEPTABLE TO MATERIAL MANUFACTURER. B. JUST PRIOR TO DATE OF SUBSTANTIAL COMPLETION, BUFF NO-WAX FLOORS USING BUFFING COMPOUND FOR NO-WAX FINISH. FOR INDICATED FLOORING TYPES, APPLY TWO COATS OF NON-SLIP WAX TO CLEAN WAXABLE FLOOR SURFACES AND BUFF. 3.7 MAINTENANCE MATERIAL: A. SALVAGE SCRAPS FROM INSTALLATION OF SHEET FLOORING GOODS OVER THREE SQ. FT. IN AREA AND OVER 1'-0" IN WIDTH FOR OWNER'S USE. END OF SECTION SECTION 09 9000 - PAINTING AND COATING PART 1 - GENERAL 1.1 SUMMARY: A. WORK OF THIS SECTION INCLUDES: 1. TOUCHING UP OF SHOP-APPLIED PRIME COATS. 2. PREPARATION OF SURFACES TO RECEIVE FINISHES. 3. PAINTING, OR OTHERWISE FINISHING OF SURFACES, EXCEPT AS OTHERWISE INDICATED. B. RELATED WORK SPECIFIED ELSEWHERE: 1. SHOP-APPLIED PRIMER COATS. 2. JOINT SEALANTS. 3. PIPING IDENTIFICATON. 4. PREFINISHED ITEMS. 1.2 DEFINITIONS: A. STANDARD COATING TERMS: AS DEFINED IN ASTM D16-12. B. COMMERCIAL: PAINTER GRADE PRODUCTS. C. DFT: DRY FILM THICKNESS OF THE COATING. D. PREMIUM: BEST QUALITY PRODUCT (TOP OF THE LINE): E. VOC: VOLATILE ORGANIC COMPOUNDS FOUND IN PRIMERS, PAINTS, SEALERS AND STAINS. VOC LEVELS ARE DESIGNATED IN GRAMS PER LITER (g/L). 1.3 PERFORMANCE REQUIREMENTS: A. DFT FOR EACH PRIMER, PAINT, SEALER AND STAIN SHALL BE AS RECOMMENDED BY PRODUCT MANUFACTURER'S PRODUCT DATA. B. VOC CONTENT: PAINTS, PRIMERS, AND SEALERS SHALL HAVE A VOC CONTENT LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1113, ARCHITECTURAL COATINGS, RULES IN EFFECT JANUARY 1, 2004. 1.4 ACTION SUBMITTALS: A. PRODUCT DATA: 1. SUBMIT COMPLETE LIST OF PRODUCTS PROPOSED FOR USE AT LEAST 30 DAYS PRIOR TO COMMENCEMENT OF PAINTING WORK. 2. INDICATE MANUFACTURER, BRAND NAME, QUALITY, TYPE, AND SHEEN FOR EACH TYPE OF PAINT AND FOR EACH SURFACE TO BE FINISHED. INDICATE VOC RATING AND COMPLIANCE WITH APPLICABLE REGULATIONS. 3. INDICATE MANUFACTURER'S INSTRUCTIONS REGARDING MIXING, SURFACE PREPARATION AND APPLICATION. INCLUDE APPLICATION RATES, FILM THICKNESS AND REQUIRED PRIMERS. 4. INTENT OF CONTRACTOR TO USE PRODUCTS SPECIFIED DOES NOT RELIEVE HIM FROM HIS RESPONSIBILITIES OF SUBMITTING PRODUCT LIST. B. VERIFICATION SAMPLES: SUBMIT TWO SETS OF SELECTED COLOR SAMPLES FROM PAINT MANUFACTURER FOR ARCHITECT'S REVIEW AND ACCEPTANCE. 1.5 QUALITY ASSURANCE: A. APPLICABLE STANDARDS: 1. ASTM INTERNATIONAL (ASTM), AS REFERENCED HEREIN. 2. ENVIRONMENTAL PROTECTION AGENCY (EPA), VOLATILE ORGANIC COMPOUNDS (VOC) STANDARDS AS REQUIRED BY LOCAL CODES AND REGULATIONS. 1.6 DELIVERY, STORAGE AND HANDLING: A. DELIVERY: DELIVER MATERIALS TO PROJECT SITE READY-MIXED IN ORIGINAL CONTAINERS WITH LABELS INTACT; LABELS BEARING MANUFACTURER'S NAME, PAINT TYPE, COLOR AND RECOMMENDED INSTALLATION AND REDUCING PROCEDURES. B. STORAGE AND HANDLING: 1. STORE MATERIALS IN LOCATION ACCEPTABLE TO ARCHITECT. 2. MAINTAIN NEAT, CLEAN CONDITIONS IN STORAGE AREA; REMOVE RAGS AND WASTE MATERIALS AT END OF EACH DAY'S WORK. 3. CLOSE CONTAINERS AT END OF DAY'S WORK. LEAVE NO MATERIALS OPEN. 1.7 PROJECT/ SITE CONDITIONS: A. ENVIRONMENTAL REQUIREMENTS: 1. COMPLY WITH MANUFACTURER'S PRODUCT DATA AS TO ENVIRONMENTAL CONDITIONS UNDER WHICH MATERIALS MAY BE APPLIED. 2. APPLY NO MATERIALS IN SPACES WHERE DUST IS BEING GENERATED. 3. COMPLY WITH APPLICABLE VOC REGULATIONS. B. PROTECTION: COVER FINISHED WORK OF OTHER TRADES AND SURFACES NOT BEING PAINTED CONCURRENTLY AND PREFINISHED ITEMS. C. SAFETY PRECAUTIONS: 1. PROVIDE TEMPORARY FIRE PROTECTION EQUIPMENT IN MATERIALS STORAGE AREA. 2. PROHIBIT SMOKING IN STORAGE AREA. PART 2 - PRODUCTS 2.1 MANUFACTURERS: A. ACCEPTABLE MANUFACTURERS: EXCEPT AS OTHERWISE NOTED, PRODUCTS SPECIFIED AS A STANDARD OF QUALITY ARE MANUFACTURED BY BENJAMIN MOORE CO. PRODUCTS OF THE FOLLOWING MANUFACTURERS SIMILAR IN TYPE AND QUALITY ARE ACCEPTABLE FOR USE, SUBJECT TO APPROVAL OF PRODUCT LIST: 1. FRAZEE PAINT. 2. DUNN-EDWARDS CORPORATION. 3. SHERWIN-WILLIAMS. B. WHERE PRODUCTS OTHER THAN THOSE OF THE MANUFACTURER LISTED AS THE STANDARD OF QUALITY ARE SPECIFIED IN PAINTING SCHEDULE, SUCH PRODUCTS HAVE BEEN SELECTED TO ACHIEVE SPECIFIC RESULTS AND SUBSTITUTIONS WILL BE ALLOWED ONLY IN ACCORD WITH PRODUCT SUBSTITUTION PROCEDURES SECTION. 2.2 PAINTING MATERIALS: A. MISCELLANEOUS MATERIALS: 1. PAINT THINNERS AND TINTS SHALL BE PRODUCTS OF SAME MANUFACTURER AS PAINTS OR APPROVED BY HIM FOR USE WITH HIS PRODUCTS. 2. SHELLAC, TURPENTINE, PATCHING COMPOUNDS AND SIMILAR MATERIALS REQUIRED FOR EXECUTION OF WORK SHALL BE PURE, BEST QUALITY PRODUCTS. B. PAINT AND STAIN COLORS SHALL BE AS INDICATED ON FINISH SCHEDULE WITH FINAL APPROVAL BASED ON BRUSH-OUT SUBMITTAL. PART 3 - EXECUTION 3.1 PREPARATION: A. INCLUDE PAINTING REQUIRED BY PROJECT EXCEPT FOR PREFINISHED ITEMS AND SPECIAL FINISHES AS SPECIFIED IN OTHER SECTIONS. B. EXISTING SURFACES: 1. FOR PREVIOUSLY PAINTED SURFACES, REMOVE DIRT, DEBRIS AND CHALK BY WASHING WITH DETERGENT AND WATER. 2. PREVIOUSLY PAINTED METAL SURFACES TO REMAIN SHALL BE WIRE-BRUSHED AND CLEANED OF EXISTING PAINT AND RUST. 3. TREAT MILDEWED SURFACES WITH A SOLUTION OF ONE QUART HYPOCHLORITE BLEACH TO A HALF CUP OF DETERGENT TO ONE GALLON WATER. RINSE AND ALLOW TO DRY PRIOR TO PAINTING. 4. SCRAPE OR USE APPROPRIATE MEANS TO REMOVE ALL LOOSE, PEELING, FLAKING, OR MARGINALLY ADHERING PAINT FROM THE SURFACE. FEATHER SAND EDGES AS NECESSARY. 5. REPAIR OR REPLACE CAULKING WHERE NEEDED. 6. AFTER CLEANING, GLOSSY SURFACES SHALL BE DULLED BY SANDING. REMOVE ALL SANDING DUST FROM THE SURFACE AFTER SANDING HAS TAKEN PLACE. 7. PREPARE BARE AREAS AS NEW SURFACES, AND STOP PRIME OR FILL THOSE AREAS WITH THE APPROPRIATE PRIMER OR FILLER. 8. PATCH OR REPAIR ALL CRACKS OR VOIDS WITH THE APPROPRIATE PATCHING COMPOUND AND SAND SMOOTH AS NECESSARY. 9. SPOT PRIME ALL PATCHED AREAS WITH THE APPROPRIATE PRIMER PRIOR TO FINISHING. 10. IF AFTER CLEANING CHALKY SURFACES CHALK RESIDUE IS STILL PRESENT, PRIME THE ENTIRE SURFACE WITH THE PROPER BONDING PRIMER TO INSURE GOOD ADHESION OF THE TOPCOAT TO THE SUBSTRATE. C. WHERE FINISH MATERIALS ABUT OR ARE ABUTTED BY DISSIMILAR MATERIALS, CAULK JOINTS IN ACCORD WITH JOINT SEALANTS SECTION. D. GYPSUM BOARD: 1. FILL NARROW, SHALLOW CRACKS AND SMALL HOLES WITH PATCHING COMPOUND, ALLOW TO DRY AND SAND SMOOTH WITHOUT RAISING NAP OF GYPSUM BOARD PAPER. 2. GYPSUM BOARD SHALL BE FINISHED AS SPECIFIED IN GYPSUM BOARD SECTION PRIOR TO PAINTING. E. FERROUS METALS: 1. WIRE-BRUSH OR SANDPAPER TO REMOVE RUST AND MILL SCALE. 2. SOLVENT-CLEAN WITH XYLOL TO REMOVE GREASE, OIL AND CONTAMINANTS. WIPE DRY WITH CLEAN CLOTH. 3.2 APPLICATIOIN: A. APPLY PAINT ONLY WHEN MOISTURE CONTENT OF SURFACES IS WITHIN LIMITS RECOMMENDED IN PRODUCT DATA. APPLY PAINT MATERIALS USING CLEAN BRUSHES, ROLLERS OR SPRAYING EQUIPMENT. B. APPLY MATERIALS AT RATE NOT EXCEEDING THAT RECOMMENDED IN PRODUCT DATA FOR SURFACE BEING PAINTED, LESS TEN PERCENT FOR LOSSES. C. COMPLY WITH PRODUCT DATA FOR DRYING TIME BETWEEN COATS. D. SAND AND DUST BETWEEN COATS TO REMOVE DEFECTS VISIBLE FROM A DISTANCE OF 5'-0". E. FINISH COATS SHALL BE SMOOTH, FREE OF BRUSH MARKS, STREAKS, LAPS OR PILE-UP OF PAINT, SKIPPED OR MISSED AREAS. F. MAKE EDGES OF PAINT ADJOINING OTHER MATERIALS OR COLORS CLEAN AND SHARP WITHOUT OVERLAPPING. G. PRIMER COATS MAY BE OMITTED FOR SURFACES SPECIFIED TO RECEIVE FACTORY- APPLIED PRIMER, IF PRIMER IS COMPATIBLE WITH FINISH COATS. IF PRIMER COATS ARE NOT COMPATIBLE, SUBSTITUTE A BOND COAT AS RECOMMENDED BY PAINT MANUFACTURER FOR SPECIFIED PRIMER COAT. H. WHERE TWO-COAT FINISH IS SPECIFIED, PRIME COAT SHALL BE TINTED TO APPROXIMATE FINISH COLOR. I. WHERE PORTION OF FINISH ON GYPSUM BOARD PARTITION IS DAMAGED OR UNACCEPTABLE, REFINISH ENTIRE SURFACE OF PARTITION. J. SEAL TOPS AND BOTTOMS OF INTERIOR DOORS WITH PRIME COAT ONLY; SIDE EDGES SAME AS FACES. K. REMOVE AND PROTECT HARDWARE, ACCESSORIES, DEVICE PLATES, LIGHTING FIXTURES, FACTORY-FINISHED WORK AND SIMILAR ITEMS, OR PROVIDE IN-PLACE PROTECTION. UPON COMPLETION OF EACH SPACE, REPLACE REMOVED ITEMS. L. PAINT EXPOSED PIPING AND DUCKWORK IN PAINTED SPACES SAME AS ADJACENT WALL SURFACES. M. THE FOLLOWING SURFACES DO NOT REQUIRE PAINTING: 1. PREFINISHED AND FACTORY-FINISHED SURFACES AND ITEMS, EXCEPT WHERE INDICATED OTHERWISE. 2. CONCEALED DUCKWORK, CONDUIT AND PIPING. 3.3 PAINT SCHEDULES: A. INTERIOR PAINT SCHEDULE: 1. GYPSUM BOARD: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER INTERIOR GYPSUM BOARD SURFACES: A. LOW-LUSTER ACRYLIC EGGSHELL FINISH: 1) FIRST COAT OVER BARE DRYWALL: MOORE #023 FRESH START ACRYLIC LATEX PRIMER 50 g/L 1.3 MILS DFT. 2) FIRST COAT OVER PREVIOUSLY PAINTED DRYWALL: MOORE #SXA-110 STIX WATERBORNE BONDING PRIMER 40% VOL SOLIDS, 2.1 MILS DFT. 3) SECOND COAT: MOORE #N538 ULTRA SPEC 500, ZERO VOC, ACRYLIC EGGSHELL ENAMEL, 1.8 MILS DFT. 4) THIRD COAT: MOORE #N538 ULTRA SPEC 500, ZERO VOC, ACRYLIC EGGSHELL ENAMEL, 1.8 MILS DFT. 2. FERROUS METAL: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER NEW AND PREVIOUSLY PAINTED FERROUS METAL: A. SEMI-GLOSS ACRYLIC ENAMEL FINISH: 1) FIRST COAT: MOORE #P04 SUPER SPEC HP ACRYLIC METAL PRIMER 54 g/L, 2.3 MILS DFT. 2) SECOND COAT: MOORE #P29 SUPER SPEC HP ACRYLIC DTM SEMI-GLOSS ENAMEL, 206 g/L, 2.5 MILS DFT. 3) THIRD COAT: MOORE #P29 SUPER SPEC HP ACRYLIC DTM SEMI-GLOSS ENAMEL, 206 g/L, 2.5 MILS DFT. 3. ZINC-COATED METAL: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER NEW AND PREVIOUSLY PAINTED INTERIOR ZINC-COATED METAL SURFACES: A. SEMI-GLOSS ACRYLIC ENAMEL FINISH: 1) FIRST COAT: MOORE #P04 SUPER SPEC HP ACRYLIC METAL PRIMER 54 g/L, 2.3 MILS DFT. 2) SECOND COAT: MOORE #P29 SUPER SPEC HP ACRYLIC DTM SEMI-GLOSS ENAMEL, 206 g/L, 2.5 MILS DFT. 3) THIRD COAT: MOORE #P29 SUPER SPEC HP ACRYLIC DTM SEMI-GLOSS ENAMEL, 206 g/L, 2.5 MILS DFT. 4. ALUMINUM: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER NEW AND PREVIOUSLY PAINTED INTERIOR ALUMINUM METAL SURFACES: A. SEMI-GLOSS ACRYLIC ENAMEL FINISH: 1) FIRST COAT: MOORE #SXA-110 STIX BONDING PRIMER 40% VOL. SOLIDS, 2.1 MILS DFT. 2) SECOND COAT: MOORE #P29 SUPER SPEC HP ACRYLIC DTM SEMI-GLOSS ENAMEL, 206 g/L, 2.5 MILS DFT. 3) THIRD COAT: MOORE #P29 SUPER SPEC HP ACRYLIC DTM SEMI-GLOSS ENAMEL, 206 g/L, 2.5 MILS DFT. END OF SECTION DIVISION 10 - SPECIALTIES SECTION 10 2123 - CUBICLE TRACK AND CURTAINS PART 1 - GENERAL 1.1 SUMMARY: A. WORK OF THIS SECTION INCLUDES CUBICLE CURTAIN TRACK, CURTAINS AND ACCESSORIES. B. RELATED WORK SPECIFIED ELSEWHERE: 1. ROUGH CARPENTRY. 2. ACOUSTICAL CEILINGS. 1.2 SUBMITTALS: A. GENERAL: IN COMPLIANCE WITH SECTION 01 3300 AND AS SPECIFIED HEREIN. B. PRODUCT DATA: SUBMIT MANUFACTURER'S PRODUCT LITERATURE AND INSTALLATION INSTRUCTIONS FOR EACH TYPE OF CUBICLE CURTAIN TRACK, CURTAIN AND INSTALLATION ACCESSORY REQUIRED. INCLUDE METHODS OF INSTALLATION FOR EACH TYPE OF SUPPORTING STRUCTURE. 1.3 QUALITY ASSURANCE: A. MANUFACTURER QUALIFICATIONS: FABRICATOR WITH NOT LESS THAN 3 YEARS OF PRODUCTION EXPERIENCE WITH CUBICLE CURTAIN TRACK, CURTAIN SIMILAR TO REQUIREMENTS OF THIS PROJECT. B. INSTALLER QUALIFICATIONS: FIRM SPECIALIZING IN CUBICLE CURTAIN TRACKS WITH NOT LESS THAN 2 YEARS OF EXPERIENCE IN INSTALLATION OF PRODUCTS SIMILAR TO THAT REQUIRED FOR THIS PROJECT. 1.4 DELIVERY, STORAGE AND HANDLING: A. COMPLY WITH INSTRUCTIONS AND RECOMMENDATIONS OF MANUFACTURER FOR SPECIAL DELIVERY, STORAGE, AND HANDLING REQUIREMENTS. B. DELIVER MATERIAL TO PROJECT SITE ON PROTECTIVE WRAPPINGS AND CONTAINERS, CLEARLY LABELED WITH IDENTIFICATION OF MANUFACTURER. STORE MATERIALS IN PACKAGES, INSIDE WELL-VENTILATED AREA PROTECTED FROM WEATHER, MOISTURE, SOILING, AND TEXTURE TEMPERATURE AND HUMIDITY. 1.5 SEQUENCING AND SCHEDULING: A. SEQUENCE CUBICLE CURTAIN TRACK, CURTAIN INSTALLATION WITH OTHER WORK TO MINIMIZE POSSIBILITY OF DAMAGE AND SOILING DURING REMAINDER OF CONSTRUCTION PERIOD. PART 2 - PRODUCTS 2.1 MANUFACTURERS: A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS OF ONE OF THE FOLLOWING: 1. BASIS OF DESIGN: GENERAL CUBICLE COMPANY, INC. 2. KIRSCH. 3. INPRO CORP. 4. AR NELSON. 2.2 TRACK MATERIALS: A. PROVIDE CUBICLE CURTAIN TRACK CONFIGURATIONS AS SHOWN ON DRAWINGS, EQUIPPED WITH HARDWARE AS SCHEDULED. B. EXTRUDED-ALUMINUM TRACK: NOT LESS THAN 1-1/4" WIDE BY 3/4" HIGH; WITH MINIMUM WALL THICKNESS OF 0.058". 1. CURVED TRACK: FACTORY FABRICATED 14" RADIUS BENDS. 2. TRACK FINISH: WHITE BAKED ENAMEL. C. PROVIDE TRACK ACCESSORIES AS REQUIRED. D. TRACK ACCESSORIES: FABRICATE SPLICES, END CAPS, CONNECTORS, END STOPS, COUPLING AND JOINING SLEEVES, WALL FLANGES, BRACKETS, CEILING CLIPS, AND OTHER ACCESSORIES FROM SAME MATERIAL AND WITH SAME FINISH AS TRACK. 1. SUSPENDED TRACK SUPPORT: NOT LESS THAN 7/8" O.D. TUBE. 2. END STOP: REMOVABLE WITH CARRIER HOOK. 3. SPLICING CLAMP: ANODIZED SLEEVE SECURING JOINED SECTIONS OF TRACK. 4. CURVES: TRACK CHANNEL BENT TO 12" RADIUS. 5. SPLICE LOCATIONS: PROVIDE CONTINUOUS TRACK ASSEMBLIES WITHOUT SPLICES WHEREVER POSSIBLE. WHERE SPLICES ARE UNAVOIDABLE, LOCATE SPLICES NO CLOSER THAN 12" FROM THE END OF A CURVED SECTION, NOR CLOSER THAN 12" TO THE END OF THE TRACK. 6. ROLLER CARRIER: BASIS OF DESIGN IS GENERAL IFC-100. 7. CURTAIN ACCESSORIES: PROVIDE TRACK ACCESSORIES TO FACILITATE USE OF CURTAINS. 2.3 CUBICLE CURTAINS: A. CUBICLE CURTAIN: 1. BASIS OF DESIGN: ICP MEDICAL 2. ALTERNATE: OWNER APPROVED EQUAL. PART 3 - EXECUTION 3.1 EXAMINATION: A. EXAMINE AREAS AND CONDITIONS WHERE CURTAIN TRACK, CURTAIN WILL BE INSTALLED. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. ONCE THE CONTRACTOR ACCEPTS AND COMMENCES THE INSTALLATION IN A ROOM OR AREA, THE CONTRACTOR SHALL REPAIR AND CORRECT DAMAGES TO THE BUILDING CONSTRUCTION RESULTING FROM HIS INSTALLATION OPERATIONS. 3.2 PREPARATION: A. PRIOR TO INSTALLATION OF CUBICLE CURTAIN TRACK AND CURTAINS, CLEAN SUBSTRATE TO REMOVE DUST, DEBRIS, AND LOOSE PARTICLES. B. COORDINATE MOUNTING OF TRACK WITH REFLECTED CEILING PLAN TO AVOID CONFLICT WITH LIGHTS, AND OTHER CEILING MOUNTED DEVICES. C. VERIFY THAT MATERIALS ARE THOSE SPECIFIED BEFORE INSTALLING. 3.3 INSTALLATION: A. INSTALL CUBICLE CURTAIN TRACK, CURTAIN UNITS IN MANNER INDICATED TO COMPLY WITH FABRICATOR'S INSTRUCTIONS. SECURE AT PROPER HEIGHT AND LOCATION RELATIVE TO ADJOINING RELATED WORK. SECURELY ANCHOR UNITS WITH PROPER ANCHORAGES, SUITED TO CEILING LEVEL, SURFACE MOUNTING. B. SECURE TRACK TO CEILING WITH FASTENERS APPROPRIATE FOR SUBSTRATE AT MINIMUM 3'-0" INTERVALS. PROVIDE TRACK ACCESSORIES AS REQUIRED. C. MAKE PROVISIONS FOR UNENCUMBERED OPERATION OF HARDWARE. 3.4 FIELD QUALITY CONTROL: A. TEST OPERATION OF EACH CUBICLE CURTAIN TRACK, CURTAIN AND ADJUST THOSE WHICH DO NOT OPERATE SMOOTHLY. 3.5 ADJUSTING: A. RETURN TO PROJECT SITE 6 MONTHS AFTER THE ARCHITECT'S FINAL CERTIFICATE, RE- HANG ANY CUBICLE CURTAIN UNITS WHICH REQUIRE MINOR ADJUSTMENT; RE-HEM CUBICLE CURTAIN UNITS WHICH HAVE STRETCHED. 3.6 CLEANING AND PROTECTION: A. REMOVE SURPLUS MATERIALS, RUBBISH, AND DEBRIS RESULTING FROM INSTALLATION UPON COMPLETION OF WORK, AND LEAVE AREAS OF INSTALLATION IN NEAT, CLEAN CONDITION. B. PROTECT TESTED AND INSTALLED UNITS TO ENSURE OPTIMUM OPERATING CONDITIONS WITHOUT DAMAGE, BLEMISHES OR INDICATION OF USE AT COMPLETION OF PROJECT. REPAIR OR REPLACE DAMAGED, SOILED OR OTHERWISE DEFECTED UNITS. END OF SECTION SECTION 10 2600 - WALL PROTECTION PART 1 - GENERAL 1.1 SUMMARY: A. WORK OF THIS SECTION INCLUDES: 1. WALL PROTECTION B. RELATED WORK SPECIFIED ELSEWHERE: GYPSUM BOARD. 1.2 REFERENCES: A. ASTM INTERNATIONAL (ASTM) B. INTERNATIONAL BUILDING CODE (IBC) C. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA); LIFE SAFETY CODE. D. UNDERWRITERS LABORATORIES (UL). 1.3 ACTION SUBMITTALS: A. PRODUCT DATA: SUBMIT PRODUCT DATA AND DETAILED SPECIFICATIONS FOR EACH SYSTEM COMPONENT AND INSTALLATION ACCESSORY REQUIRED, INCLUDING INSTALLATION METHODS FOR EACH TYPE OF SUBSTRATE. B. SAMPLES: SAMPLES FOR VERIFICATION PURPOSES: SUBMIT 12" LONG SAMPLE OF EACH MODEL SPECIFIED AND AS PROPOSED FOR THIS WORK, FOR VERIFICATION OF GUARD. 1.4 QUALITY ASSURANCE: A. INSTALLER QUALIFICATIONS: ENGAGE AN INSTALLER WHO HAS NO LESS THAN 3 YEARS EXPERIENCE IN INSTALLATION OF SYSTEMS SIMILAR IN COMPLEXITY TO THOSE REQUIRED FOR THIS PROJECT. B. MANUFACTURER'S QUALIFICATIONS: NOT LESS THAN 5 YEARS EXPERIENCE IN THE PRODUCTION OF SPECIFIED PRODUCTS AND A RECORD OF SUCCESSFUL IN-SERVICE PREFORMANCE. C. CODE COMPLIANCE: ASSEMBLIES SHALL CONFORM TO APPLICABLE CODES INCLUDING IBC, AND LIFE SAFETY. D. FIRE PERFORMANCE CHARACTERISTICS: PROVIDE WALL PROTECTION SYSTEM COMPONENTS WITH UL LABEL INDICATING THAT THEY ARE IDENTICAL TO THOSE TESTED IN ACCORD WITH ASTM E84-12A FOR CLASS 1 CHARACTERISTICS LISTED BELOW" 1. FLAME SPREAD: 25 OR LESS 2. SMOKE DEVELOPED: 450 OR LESS. E. IMPACT STRENGTH: PROVIDE ASSEMBLED WALL PROTECTION UNITS THAT HAVE BEEN TESTED IN ACCORD WITH THE APPLICABLE PROVISIONS OF ASTM F476-84(2002) F. CHEMICAL AND STAIN RESISTANCE: PROVIDE WALL PROTECTION SYSTEM COMPONENTS WITH CHEMICAL AND STAIN RESISTANCE IN ACCORDANCE WITH ASTM D1308-02(2007). G. COLOR MATCH: PROVIDE WALL PROTECTION COMPONENTS THAT ARE COLOR MATCHED IN ACCORDANCE WITH THE FOLLOWING: 1. DELTA ECMC OF NO GREATER THAN 1.0 USING CIELAB COLOR SPACE. H. SINGLE SOURCE RESPONSIBILITY: PROVIDE ALL COMPONENTS OF THE WALL PROTECTION SYSTEM MANUFACTURED BY THE SAME COMPANY TO ENSURE COMPATIBILITY OF COLOR, TEXTURE AND PHYSICAL PROPERTIES. 1.5 DELIVERY, STORAGE AND HANDLING: A. DELIVER MATERIALS TO THE PROJECT SITE IN UNOPENED ORIGINAL FACTORY PACKAGING CLEARLY LABELED TO SHOW MANUFACTURER. B. STORE MATERIALS IN ORIGINAL, UNDAMAGED PACKAGING IN A COOL, DRY PLACE OUT OF DIRECT SUNLIGHT AND EXPOSURE TO THE ELEMENTS. MAINTAIN A MINIMUM ROOM TEMPERATURE OF 40 DEGREES F. AND A MAXIMUM TEMPERATURE OF 100 DEGREES F. C. STORE MATERIAL FLAT. 1.6 PROJECT CONDITIONS: A. ACCLIMATE MATERIALS IN AN ENVIRONMENT OF 65 DEGREES TO 75 DEGREES FOR AT LEAST 24 HOURS PRIOR TO BEGINNING INSTALLATION. B. INSTALLATION AREAS SHALL BE ENCLOSED AND WEATHERPROOFED BEFORE INSTALLATION COMMENCES. PART 2 - PRODUCTS 2.1 CORNER GUARDS: A. ENGINEERING PETG: HIGH IMPACT ACROVYN 4000 WITH NOMINAL .040" THICKNESS. B. ALUMINUM EXTRUSIONS: ALLOY AND TEMPER RECOMMENDED BY MANUFACTURER FOR TYPE OF USE AND FINISH INDICATED, BUT WITH NOT LESS THAN STRENGTH AND DURABILITY PROPERTIES SPECIFIED IN ASTM B221-12A FOR ALLOY 6063-T5. C. FASTENERS: ALUMINUM, NONMAGNETIC STAINLESS-STEEL, OR OTHER NONCORROSIVE METAL SCREWS, BOLTS, AND OTHER FASTENERS COMPATIBLE WITH ITEMS BEING FASTENED. USE SECURITY-TYPE FASTENERS WHERE EXPOSED TO VIEW. D. ADHESIVE: AS RECOMMENDED BY IMPACT-RESISTANT PLASTIC WALL PROTECTION MANUFACTURER'S PRODUCT DATA AND WITH A VOC CONTENT LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1113, ARCHITECTURAL COATINGS, RULES IN EFFECT JANUARY 1, 2004. E. REFER TO FINISH SCHEDULE. 2.2 FABRICATION: A. FABRICATE IMPACT-RESISTANT WALL PROTECTION UNITSTO COMPLY WITH REQUIREMENTS INDICATED FOR DESIGN, DIMENSIONS, AND MEMBER SIZES, INCLUDING THICKNESSES OF COMPONENTS. B. ASSEMBLE COMPONENTS IN FACTORY TO GREATEST EXTENT POSSIBLE TO MINIMIZE FIELD ASSEMBLY. DISASSEMBLE ONLY AS NECESSARY FOR SHIPPING AND HANDLING. C. FABRICATE COMPONENTS WITH TIGHT SEAMS AND JOINTS WITH EXPOSED EDGES ROLLED. PROVIDE SURFACES FREE OF WRINKLES, CHIPS, DENTS, UNEVEN COLORATION, AND OTHER IMPERFECTIONS. FABRICATE MEMBERS AND FITTINGS TO PRODUCE FLUSH, SMOOTH, AND RIGID HAIRLINE JOINTS. PART 3 - EXECUTION 3.1 EXAMINATION: A. EXAMINE SUBSTRATES AND WALL AREAS, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH REQUIREMENTS FOR INSTALLATION TOLERANCES AND OTHER CONDITIONS AFFECTING PERFORMANCE OF WORK. B. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 3.2 PREPARATION: A. COMPLETE FINISHING OPERATIONS, INCLUDING PAINTING , BEFORE INSTALLING IMPACT-RESISTANT WALL PROTECTION SYSTEM COMPONENTS. B. BEFORE INSTALLATION, CLEAN SUBSTRATE TO REMOVE DUST, DEBRIS, AND LOOSE PARTICLES. 3.3 INSTALLATION: A. GENERAL: INSTALL IMPACT-RESISTANCE HANDRAILS UNITS LEVEL, PLUMB, AND TRUE TO LINE WITHOUT DISTORTIONS. DO NOT USE MATERIALS WITH CHIPS, CRACKS, VOIDS, STAINS, OR OTHER DEFECTS THAT MIGHT BE VISIBLE IN THE FINISHED WORK. 3.4 CLEANING: A. IMMEDIATELY AFTER COMPLETION OF INSTALLATION, CLEAN PLSTIC COVERS AND ACCESSORIES USING A STANDARD, AMMONIA-BASED, HOUSEHOLD CLEANING AGENT. B. REMOVE EXCESS ADHESIVE USING METHODS AND MATERIALS RECOMMENDED IN MANUFACTURER'S PRODUCT DATA. END OF SECTION DIVISION 11 THRU 21 (NO SECTIONS REQUIRED) DIVISION 22 PROVIDED ON PLUMBING DRAWINGS DIVISION 23 PROVIDED ON MECHANICAL DRAWINGS DIVISION 24 (NO SECTIONS REQUIRED) DIVISION 25 (NO SECTIONS REQUIRED) DIVISION 26 PROVIDED ON ELECTRICAL DRAWINGS DIVISION 27 THRU 49 (NO SECTIONS REQUIRED) R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:23:29 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) G0-04 SPECIFICATIONS CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 DIVISION 14 (NO SECTIONS REQUIRED) DIVISION 15 (NO SECTIONS REQUIRED) DIVISION 16 (NO SECTIONS REQUIRED) DIVISION 17 (NO SECTIONS REQUIRED) DIVISION 18 (NO SECTIONS REQUIRED) DIVISION 19 (NO SECTIONS REQUIRED) DIVISION 20 (NO SECTIONS REQUIRED) DIVISION 21 (NO SECTIONS REQUIRED) DIVISION 22 PROVIDED ON PLUMBING DRAWINGS DIVISION 23 PROVIDED ON MECHANICAL DRAWINGS DIVISION 24 (NO SECTIONS REQUIRED) DIVISION 25 (NO SECTIONS REQUIRED) DIVISION 26 PROVIDED ON ELECTRICAL DRAWINGS DIVISION 27 THRU 49 (NO SECTIONS REQUIRED) DIVISION 13 - SPECIAL CONSTRUCTION SECTION 13 4900 - RADIATION PROTECTION 1.1 SUMMARY A. SECTION INCLUDES 1. LEAD SHEET, STRIP, AND PLATE 2. LEAD-LINED GYPSUM BOARD. 3. LEAD GLASS 4. LEAD-LINED FLUSH WOOD DOORS 5. LEAD-LINED HOLLOW METAL FRAME 1.2 SUBMITTALS A. PRODUCT DATA B. SHOP DRAWINGS SHOWING INSTALLATION CONDITIONS FOR DUCTS, PIPES, CONDUIT, AND OTHER OBJECTS THAT PENETRATE RADIATION PROTECTION. C. QUALIFICATION DATA: 1. FOR INSTALLER 2. FOR FLUSH WOOD DOOR MANUFACTURER QUALIFICATIONS 2.1 PERFORMANCE REQUIREMENTS A. PROVIDE MATERIALS AND WORKMANSHIP, INCLUDING JOINTS AND FASTENERS, THAT MAINTAIN CONTINUITY OF RADIATION PROTECTION AT ALL POINTS AND IN ALL DIRECTIONS EQUIVALENT TO MATERIALS SPECIFIED IN THICKNESSES AND LOCATIONS INDICATED. 1. MATERIALS, THICKNESSES, AND CONFIGURATIONS INDICATED ARE BASED ON RADIATION PROTECTION DESIGN PREPARED BY OWNER'S RADIATION HEALTH PHYSICIST. 2.2 MATERIALS A. LEAD SHEET, STRIP, AND PLATE: ASTM B 749, ALLOY UNS NO. L51121 (CHEMICAL COPPER LEAD). B. LEAD-LINED GYPSUM BOARD: 5/8-INCH THICK GYPSUM BOARD COMPLYING WITH SECTION 09 2900 "GYPSUM BOARD," OF WIDTH AND LENGTH REQUIRED FOR SUPPORT SPACING AND TO PREVENT CRACKING DURING HANDLING, AND WITH A SINGLE SHEET OF LEAD LAMINATED TO THE BACK OF THE BOARD. 1. FURNISH 3" WIDE LEAD STRIPS FOR WRAPPING METAL STUD FLANGES 2. FURNISH 2" WIDE LEAD STRIPS FOR BACKING JOINTS 3. FURNISH 5/8" DIAMETER LEAD DISKS FOR COVERING SCREW HEADS C. LEAD GLASS: LEAD-BARIUM, POLISHED GLASS CONTAINING NOT LESS THAN 60 PERCENT HEAVY METAL OXIDES, INCLUDING NOT LESS THAN 48 PERCENT LEAD OXIDE BY WEIGHT. D. LEAD-LINED, HOLLOW-METAL DOOR FRAMES 1. GENERAL: STEEL DOOR FRAMES COMPLYING WITH NAAMM-HMMA 861, ]LINED WITH LEAD SHEET OF THICKNESS NOT LESS THAN THAT REQUIRED FOR DOORS AND WALLS WHERE FRAMES ARE USED. 2. FURNISH WITH ADDITIONAL REINFORCEMENTS AND INTERNAL SUPPORTS TO ADEQUATELY CARRY THE WEIGHT OF LEAD-LINED DOORS. INSTALL REINFORCEMENTS AND SUPPORTS BEFORE INSTALLING LEAD LINING. 3. FORM LEAD SHEET TO MATCH FRAME CONTOUR, CONTINUOUS IN EACH JAMB AND ACROSS THE HEAD, LAPPING THE STOPS. FORM LEAD SHIELDS AROUND AREAS PREPARED TO RECEIVE HARDWARE. FABRICATE LEAD LINING WIDE ENOUGH TO MAINTAIN AN EFFECTIVE LAP WITH LEAD OF ADJACENT SHIELDING. E. LEAD-LINED FLUSH WOOD DOORS 1. LEAD-LINED FLUSH WOOD DOORS: SOLID-CORE WOOD DOORS WITH LEAD LINING, THICKNESS NOT LESS THAN THAT REQUIRED FOR PARTITION IN WHICH DOOR IS INSTALLED 2. GRADE: CUSTOM 3. FACE VENEER SPECIES AND CUT: MATCH WOOD DOORS THAT ARE NOT LEAD LINED 4. COLOR, PATTERNS, AND FINISHES: AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGE 5. FACTORY FIT DOORS TO SUIT FRAME OPENINGS INDICATED WITH 1/16-INCH CLEARANCE AT HEADS AND JAMBS AND MINIMUM CLEARANCE AT BOTTOM. FACTORY MACHINE DOORS FOR HARDWARE NOT SURFACE APPLIED. 3.1 INSTALLATION OF LEAD-LINED GYPSUM BOARD A. INSTALL WITH LONG EDGE PARALLEL TO SUPPORTS AND LEAD LINING FACING SUPPORTS. PROVIDE BLOCKING AT END JOINTS. B. FASTENING TO METAL SUPPORTS: USE STEEL DRILL SCREWS SPACED AS RECOMMENDED IN WRITING BY GYPSUM BOARD MANUFACTURER. 1. INSTALL LEAD STRIPS, 2 INCHES (50 MM) WIDE AND SAME THICKNESS AS LEAD LINING, TO FACE OF SUPPORTS AND BLOCKING WHERE JOINTS OCCUR. SECURE LEAD STRIPS WITH CONSTRUCTION ADHESIVE. PROVIDE SHIMS AT FACE OF SUPPORTS AND BLOCKING WHERE JOINTS DO NOT OCCUR. C. OPENINGS: EXTEND LEAD-LINED GYPSUM BOARD INTO FRAMES OF OPENINGS, LAPPING LEAD LINING WITH LEAD FRAMES OR FRAME LININGS AT LEAST 1 INCH (25 MM). ARRANGE BOARD AROUND OPENINGS SO NEITHER HORIZONTAL NOR VERTICAL JOINTS OCCUR AT CORNERS OF OPENINGS. D. FINISH LEAD-LINED GYPSUM BOARD TO COMPLY WITH SECTION 092900 "GYPSUM BOARD." 3.2 INSTALLATION OF LEAD-LINED DOORS AND DOOR FRAMES A. INSTALL LEAD-LINED STEEL DOOR FRAMES ACCORDING TO SECTION 08 1113 1. COMPLY WITH HMMA 840 UNLESS OTHERWISE INDICATED. EXCEPT FOR FRAMES LOCATED IN EXISTING WALLS OR PARTITIONS, PLACE FRAMES BEFORE CONSTRUCTING WALLS. SET FRAMES ACCURATELY IN POSITION, PLUMB, AND BRACE SECURELY UNTIL PERMANENT ANCHORS ARE SET. 2. PROVIDE THREE ANCHORS PER JAMB, LOCATED ADJACENT TO HINGE ON HINGE JAMB AND AT CORRESPONDING HEIGHTS ON STRIKE JAMB. 3. IN MASONRY CONSTRUCTION, USE WIRE OR T-STRAP ANCHORS AND APPLY A COAT OF ASPHALT MASTIC OR PAINT TO LEAD LINING WHERE LEAD COMES IN CONTACT WITH MASONRY OR GROUT. 4. IN METAL STUD CONSTRUCTION, USE WALL ANCHORS ATTACHED TO STUDS WITH SCREWS. 5. LEAD LINING OF FRAMES: LINE INSIDE OF FRAMES WITH LEAD OF THICKNESS NOT LESS THAN THAT REQUIRED IN DOORS AND WALLS WHERE FRAMES ARE USED. FORM LEAD TO MATCH FRAME CONTOUR, CONTINUOUS IN EACH JAMB AND ACROSS THE HEAD, LAPPING THE STOPS. FORM LEAD SHIELDS AROUND AREAS PREPARED TO RECEIVE HARDWARE. LAP LINING OVER LINING IN WALLS AT LEAST 1 INCH B. INSTALL LEAD-LINED WOOD DOORS ACCORDING TO SECTION 08 1416 1. INSTALL DOORS IN FRAMES LEVEL AND PLUMB, ALIGNED WITH FRAMES AND WITH UNIFORM CLEARANCE AT EACH EDGE. 2. HARDWARE: LINE COVERS, ESCUTCHEONS, AND PLATES TO PROVIDE EFFECTIVE SHIELDING AT CUTOUTS AND PENETRATIONS OF FRAMES AND DOORS. SEE SECTION 08 7100 "DOOR HARDWARE" FOR OTHER INSTALLATION REQUIREMENTS. 3. OPERATION: REHANG OR REPLACE DOORS THAT DO NOT SWING OR OPERATE FREELY. CHECK AND READJUST OPERATING HARDWARE ITEMS, LEAVING DOORS AND FRAMES UNDAMAGED AND IN PROPER OPERATING CONDITION. C. GLAZING: COMPLY WITH INSTALLATION REQUIREMENTS IN SECTION 08 8000 3.3 INSTALLATION OF PENETRATING ITEMS A. AT PENETRATIONS OF LEAD LININGS, PROVIDE LEAD SHIELDS TO MAINTAIN CONTINUITY OF PROTECTION. B. PROVIDE LEAD LININGS, SLEEVES, SHIELDS, AND OTHER PROTECTION IN THICKNESS NOT LESS THAN THAT REQUIRED IN ASSEMBLY BEING PENETRATED. C. SECURE SHIELDS AT PENETRATIONS USING ADHESIVE OR WIRE TIES BUT NOT PENETRATING FASTENERS UNLESS INDICATED ON DRAWINGS. D. OUTLET BOXES AND CONDUIT: COVER OR LINE WITH LEAD SHEET LAPPED OVER ADJACENT LEAD LINING AT LEAST 1 INCH (25 MM). WRAP CONDUIT WITH LEAD SHEET FOR A DISTANCE OF NOT LESS THAN 10 INCHES (250 MM) FROM BOX. E. DUCT OPENINGS: UNLESS OTHERWISE INDICATED, LINE OR WRAP DUCTS WITH LEAD SHEET FOR DISTANCE FROM PARTITION/CEILING EQUAL TO THREE TIMES THE LARGEST OPENING DIMENSION. LAP LEAD SHEET WITH ADJACENT LEAD LINING AT LEAST 1 INCH. F. PIPING: UNLESS OTHERWISE INDICATED, WRAP PIPING WITH LEAD SHEET FOR A DISTANCE OF NOT LESS THAN 10 INCHES (250 MM) FROM POINT OF PENETRATION. 3.4 FIELD QUALITY CONTROL A. TESTING AGENCY: OWNER WILL ENGAGE A QUALIFIED TESTING AGENCY TO PERFORM TESTS AND INSPECTIONS AFTER RADIOLOGY EQUIPMENT HAS BEEN INSTALLED AND PLACED IN OPERATING CONDITION. B. CORRECT DEFICIENCIES IN OR REMOVE AND REPLACE RADIATION PROTECTION THAT INSPECTION REPORTS INDICATE DOES NOT COMPLY WITH SPECIFIED REQUIREMENTS. C. PREPARE TEST AND INSPECTION REPORTS END OF SECTION SECTION 28 1000 ACCESS CONTROL AND ALARM MONITORING SYSTEM PART 1 - GENERAL 1. SECTION INCLUDES A. MATERIALS, EQUIPMENT, FABRICATION, INSTALLATION AND TESTS IN CONFORMITY WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION FOR THE FOLLOWING: 1. A COMPLETE ACCESS CONTROL AND ALARM MONITORING SYSTEM AS DESCRIBED IN THE SPECIFICATIONS AND AS SHOWN IN DETAIL ON THE DRAWINGS. 2. COMPLETE SYSTEM IS DEFINED AS ALL LABOR AND MATERIALS REQUIRED TO COMPLETE THE WORK DESCRIBED HEREIN AND ON THE DRAWINGS INCLUDING BUT NOT LIMITED TO: CONDUIT, RACEWAYS, CABLES, CABLING, CONNECTORS, RISERS, NETWORK INTERFACES, BACK BOXES, CARD READERS, CARDS, REQUEST TO EXIT SENSORS, MOTION DETECTORS, ALARM CONTACTS, CONTROLLERS, SPECIFIC ALARM PANELS, ACCESS CONTROL PANELS, POWER SUPPLIES, TRANSFORMERS, UPS’S, PRINTERS, INTERCOMS, INTERCOM HEAD-END EQUIPMENT AND PROGRAMMING, TELEPHONES, PROGRAMMING, LABOR, HARD DRIVES, SOFTWARE UPGRADES, LICENSE UPGRADES, SOFTWARE SUPPORT LICENSES AND ACCESS CONTROL HEAD END SOFTWARE. ALSO PROVIDE AND INSTALL REQUIRED COMMUNICATION EQUIPMENT AND GEAR, PHONE LINE MONITORING, POWER FILTERING, ENCLOSURES, TAMPER SWITCHES, LATCHES AND LOCKS, MOUNTS, HOUSINGS, STANDS, INTERFACES TO NEW AND EXISTING ELECTRIFIED DOOR HARDWARE, INTERFACES TO AUTOMATIC DOOR OPERATORS AND INTERFACES TO EQUIPMENT FURNISHED BY OTHERS. 3. PRODUCTS, EQUIPMENT, MATERIALS, SYSTEMS, ASSEMBLIES, SOFTWARE AND ACCESSORIES AS SPECIFIED HEREIN DEFINE THE MINIMUM STANDARDS. SPECIFICATIONS AND DRAWINGS DO NOT SHOW OR LIST EVERY ITEM, ACCESSORY, FASTENER, BRACKET, SUB-ASSEMBLY AND APPURTENANCE TO BE PROVIDED. WHEN AN ITEM NOT SHOWN OR LISTED IS CLEARLY NECESSARY FOR PROPER INSTALLATION, OPERATION AND FUNCTIONING OF THE EQUIPMENT AND SYSTEMS THE SECURITY CONTRACTOR SHALL PROVIDE, INSTALL, TEST AND CERTIFY THE ITEM AT NO INCREASE IN CONTRACT PRICE. 4. THE LENEL ACCESS CONTROL SERVER WILL COMMUNICATE TO THE ACCESS CONTROL FIELD PANELS VIA A NETWORK CONNECTION OVER THE OWNER’S LAN/WAN. SECURITY CONTRACTOR SHALL COORDINATE IP ADDRESSES, LAN DROPS, NETWORK CONNECTIVITY AND BANDWIDTH ALLOCATION AND USAGE WITH THE OWNER’S IT DEPARTMENT. 5. PROVIDE ALL SOFTWARE, HARDWARE, AND PROGRAMMING FOR INSTALLATION, CONNECTION AND OPERATION OF THE NEW SECURITY SYSTEM EQUIPMENT. 6. SECURITY CONTRACTOR IS RESPONSIBLE FOR FULLY IMPLEMENTING THE FUNCTIONS DESCRIBED IN THE SPECIFICATIONS AND SHOWN ON THE DRAWINGS. 7. COORDINATE ALL TELEPHONE AND DATA NETWORK CONNECTIONS, PROGRAMMING, AND REQUIREMENTS WITH OWNER’S IT DEPARTMENT. 8.FURNISH AND INSTALL ANY INTERFACE RELAYS, MATERIALS, AND CABLING REQUIRED FOR CONNECTION TO THE FIRE ALARM CONTROL PANEL (FACP). 1. RELATED SECTIONS A. CONDUIT, WIRE AND CABLE INSTALLATIONS PERFORMED UNDER THIS DIVISION SHALL COMPLY WITH ALL APPLICABLE SECTIONS OF THE LOCAL BUILDING CODES, CALIFORNIA ELECTRICAL CODE AND DIVISION 26 REQUIREMENTS. B.COORDINATE DOOR HARDWARE WITH THE DIVISION 8 HARDWARE CONTRACTOR. C.COORDINATE ALL ELECTRICAL POWER AND CONDUIT REQUIREMENTS WITH THE DIVISION 26 ELECTRICAL CONTRACTOR AND THE OWNER. ALL SECURITY SYSTEMS SHALL BE ON AN EMERGENCY POWER BRANCH CIRCUIT. 1. REFERENCES A. PUBLISHED SPECIFICATIONS, STANDARDS, TESTS AND CODES AND RECOMMENDED STANDARDS OF TRADE, INDUSTRY OR GOVERNMENTAL ORGANIZATIONS APPLY TO WORK IN THIS SECTION INCLUDING: 1. ADA – TITLE 3 OF THE AMERICANS WITH DISABILITIES ACT 2. ASCII – AMERICAN STANDARD CODE FOR INFORMATION INTERCHANGE 3. ASTM – AMERICAN SOCIETY FOR TESTING AND MATERIALS 4. CCR – TITLES 19 AND 24 OF THE CALIFORNIA CODE OF REGULATIONS 5. EIA – ELECTRONIC INDUSTRY ASSOCIATION 6. NEMA – NATIONAL ELECTRICAL MANUFACTURERS' ASSOCIATION 7. NFPA – 2002 NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS 8. CEC – 2005 NATIONAL ELECTRICAL CODE WITH 2007 CA AMENDMENTS 9. CBC – 2006 INTERNATIONAL BUILDING CODE WITH 2007 CA AMENDMENTS 10. CFC – 2006 INTERNATIONAL FIRE CODE WITH 2007 CA AMENDMENTS 11. CMC – 2006 INTERNATIONAL MECHANICAL CODE WITH 2007 CA AMENDMENTS 12. UL – UNDERWRITERS LABORATORIES, INC. B.ELECTRONIC DEVICES RADIATING "RF" ENERGY SHALL COMPLY WITH FEDERAL COMMUNICATION COMMISSION REGULATIONS, PARTICULARLY PART FIFTEEN, AND SHALL MEET MINIMUM CLASS "B" REQUIREMENTS. PROVIDE FCC CERTIFICATE NUMBERS INDICATING THAT THE FCC HAS APPROVED THE PRODUCTS. 1. QUALITY ASSURANCE A. SECURITY CONTRACTOR SHALL BE CAPABLE OF PERFORMING SERVICE OR MAINTENANCE WORK ON THE SPECIFIED SYSTEMS. SECURITY CONTRACTOR’S LEAD TECHNICIAN SHALL BE FACTORY-CERTIFIED BY THE SECURITY SYSTEM MANUFACTURER. B.SECURITY CONTRACTOR TO PROVIDE AS PART OF THEIR QUOTE DOCUMENTATION OF NATIONAL SOURCING AGREEMENTS (NSA) DISCOUNTS FOR LENEL EQUIPMENT. DOCUMENTATION SHALL INCLUDE LENEL MSRP PRICE, KAISER NSA DISCOUNT PERCENTAGE AND REVISED PRICE. C.SECURITY CONTRACTOR MUST BE A LENEL AUTHORIZED DEALER. THE SECURITY CONTRACTOR SHALL POSSESS ALL REQUIRED CONTRACTOR'S LICENSES. 1. SUBMITTALS A. SUBMIT THE FOLLOWING TO THE ARCHITECT FOR APPROVAL PRIOR TO COMMENCEMENT OF WORK: 1. MANUFACTURER'S NAME, BRAND NAME, EXACT PART NUMBER, OPTIONS, ACCESSORIES AND CATALOG REFERENCES FOR ALL EQUIPMENT SUPPLIED. INDICATE UL LISTINGS FOR ALL SYSTEM COMPONENTS. 2. COMPLETE WIRING DIAGRAMS FOR ALL COMPONENTS, INCLUDING CABLE TYPES AND QUANTITIES, ROUTINGS, FLOOR PLANS INDICATING DEVICE LOCATIONS, CONDUIT SIZES, POINT- TO-POINT TERMINATION AND RISER DIAGRAMS. B.SUBMITTALS MUST BE COMPLETE. ALL SECURITY SYSTEM SUBMITTALS SHALL BE IN A SIMILAR FORMAT FOR EASE OF REVIEW. THE ARCHITECT AND SECURITY CONSULTANT RESERVE THE RIGHT TO REJECT ANY SUBMITTALS DETERMINED TO BE INCOMPLETE. REJECTION OF SUBMITTALS FOR FAILURE TO MEET THESE REQUIREMENTS SHALL NOT BE CONSIDERED GROUNDS FOR CLAIMS OF DELAY. PART 2 - PRODUCTS 2.1 ACCESS CONTROL AND ALARM MONITORING SYSTEM PRODUCTS A. CARD READER DOORS 1. SECURITY CONTRACTOR TO PROVIDE AND INSTALL 12 INCH BY 12 INCH SECURITY JUNCTION BOX IN THE ACCESSIBLE CEILING SPACE ABOVE OR NEAR EACH CARD READER DOOR. INSTALL THE JUNCTION BOX SO THAT IT IS ACCESSIBLE FROM THE SECURED SIDE OF THE DOOR AND NOT BLOCKED BY EXIT LIGHTING, AIR GRILLS, VENTS, SPRINKLERS OR SMOKE DETECTORS. a. SECURITY CONTRACTOR TO INSTALL THE LNL-1300 OR LNL-1320 READER INTERFACE MODULE IN THE SECURITY JUNCTION BOX ASSOCIATED WITH EACH CARD READER DOOR. b. LABEL ALL WIRES AND CABLES WITH MACHINE- GENERATED LABELS AS CLOSE AS POSSIBLE TO THEIR TERMINATION POINT. ALL LABELS SHALL BE CLEARLY VISIBLE WITHOUT THE NEED TO MOVE OTHER CABLES OR REMOVE ANY CABLE MANAGEMENT DEVICES SUCH AS TIE WRAPS. c. INSTALL SUFFICIENT TERMINAL BLOCKS IN THE SECURITY JUNCTION BOX TO MAKE UP ALL WIRE-TO-WIRE CONNECTIONS. NO WIRE-NUT CONNECTIONS ARE PERMITTED. d. ALL WIRING WITHIN THE SECURITY JUNCTION BOX SHALL BE DRESSED NEATLY AND PROFESSIONALLY. e. PROVIDE SUFFICIENT SPARE CABLE LENGTH FOR EACH CABLE TO FORM A SERVICE LOOP TO ENABLE IT TO REACH ANY POINT WITHIN THE SECURITY JUNCTION BOX WITHOUT THE NEED FOR SPLICING ADDITIONAL WIRE OR PULLING ADDITIONAL CABLE IN FROM OUTSIDE THE SECURITY JUNCTION BOX. f. ALL SECURITY JUNCTION BOXES SHALL BE CLEARLY MARKED ON THE OUTSIDE COVER SO THAT THEY CAN BE IDENTIFIED FROM THE FLOOR BELOW WITHOUT THE USE OF A LADDER WHEN THE ACCESSIBLE CEILING SPACE IS OPEN. MARKINGS SHALL REFLECT THE DOOR NUMBER AS WELL AS THE ACCESS CONTROL PANEL NUMBER AND PORT ASSOCIATED WITH THAT CARD READER DOOR. G.ALL INITIATING CIRCUITS SHALL BE WIRED NORMALLY CLOSED WITH A 5-STATE SUPERVISION 1K/2K RESISTOR INSTALLED AT THE END-OF-LINE DEVICE. B.CARD READER DOOR DEVICES 1. SECURITY CONTRACTOR TO PROVIDE AND INSTALL HID CORPORATION THINLINE II CLASSIC STYLE CARD READERS. NO SUBSTITUTIONS WILL BE ACCEPTED. a. THE CARD READER SHALL COMMUNICATE IN A WIEGAND PROTOCOL INTERFACE AND BE COMPATIBLE WITH ALL STANDARD ACCESS CONTROL SYSTEMS. b. CARD READERS INSTALLED AT INTERIOR LOCATIONS SHALL BE WHITE IN COLOR. 2. SECURITY CONTRACTOR TO PROVIDE AND INSTALL DETECTION SYSTEMS DS160 REQUEST-TO- EXIT MOTION DETECTOR AND TP160 MOUNTING PLATE AT ALL CARD READER DOOR LOCATIONS. NO SUBSTITUTIONS WILL BE ACCEPTED. a. REQUEST-TO-EXIT MOTION DETECTORS SHALL BE WIRED NORMALLY CLOSED WITH A 5-STATE SUPERVISION 1K/2K RESISTOR INSTALLED AT THE END-OF-LINE DEVICE. 3. SECURITY CONTRACTOR TO PROVIDE AND INSTALL GE SENTROL 1076(D) CONCEALED ALARM CONTACT IN DOOR FRAMES AND CONCEALED MAGNETS IN DOOR LEAFS AT ALL CARD READER DOOR LOCATIONS. a. CONTACT SHALL CONSIST OF 2 SPDT CONTACTS IN ONE SWITCH. b. CONTACT SHALL HAVE AN ALARM GAP DISTANCE OF NO MORE THAN 1/2 INCH. c. DOOR CONTACTS SHALL BE WIRED NORMALLY CLOSED WITH A 5-STATE SUPERVISION 1K/2K RESISTOR INSTALLED AT THE END-OF-LINE DEVICE. d. CONTACT COLOR SHALL BE PROVIDED TO BEST MATCH DOOR FRAME FINISH. e. CONTACT SHALL NOT BE LARGER THAN 3/4 INCH. f. PAIRS OF DOORS SHALL HAVE ALARM CONTACTS ON EACH DOOR LEAF AND THE ALARM CONTACTS WILL BE WIRED IN A SERIES CIRCUIT. 4. SECURITY CONTRACTOR TO PROVIDE SWITCHED LOCK POWER TO ELECTRIFIED LOCKS AND STRIKES. a. LOCKS SHALL UNLOCK WHEN 24 VDC POWER IS APPLIED FOR A “FAIL SECURE” OPERATION. b. THE LNL-1300 OR LNL-1320 READER INTERFACE MODULE SHALL BE USED TO SWITCH THE LOCK POWER TO THE LOCKS. 5. THE SECURITY CONTRACTOR SHALL PROVIDE AND INSTALL A LABEL AT EACH READER LOCATION. LABELS SHALL BE MACHINE GENERATED AND BE ON THE BOTTOM OF THE READER INDICATING THE READER NUMBER IN THE SYSTEM. C.POWER SUPPLIES 1. SECURITY CONTRACTOR TO PROVIDE AND INSTALL ALTRONIX AL1012ULX16CB AND AL1024ULX16CB POWER SUPPLIES WITH POWER DISTRIBUTION MODULES TO POWER ALL ACCESS CONTROL PANELS, INTRUSION ALARM PANELS, ELECTRICALLY CONTROLLED DOOR LOCKS AND DOOR STRIKES, REQUEST TO EXITS AND PERIPHERAL DEVICES AT LOCATIONS AS SHOWN ON THE DRAWINGS. NO SUBSTITUTIONS WILL BE ACCEPTED. a. POWER SUPPLY/CHARGER UNITS SHALL BE CLASS 2 RATED. b. INSTALL EACH INDIVIDUAL LOCK, REQUEST TO EXIT AND PERIPHERAL DEVICE ON A SEPARATE OUTPUT OF THE POWER DISTRIBUTION MODULE. c. PROVIDE SUFFICIENT QUANTITY OF POWER SUPPLIES WITH FACTORY-INSTALLED POWER DISTRIBUTION MODULES TO PERMIT SIMULTANEOUS CONTINUOUS-DUTY ACTIVATION OF ALL DOOR LOCKS WITH AN ADDITIONAL MINIMUM 20 PERCENT CAPACITY ON EACH SUPPLY. d. CALCULATE VOLTAGE DROP TO LOCKS AND SIZE LOCK CONTROL WIRING TO PROVIDE PROPER LOCK OPERATION. e. PROVIDE BATTERY BACK-UP SUFFICIENT FOR FOUR HOURS STANDBY PLUS TWENTY-FIVE ACTIVATIONS FOR ALL DC LOCKS. BATTERIES SHALL BE 12V 7AHR. f. MONITOR THE AC FAIL RELAY FOR POWER FAILURE AND THE LOW BATTERY RELAY FOR LOW BATTERY. THESE ALARMS SHALL HAVE INDIVIDUAL MONITOR POINTS ON THE ACCESS CONTROL SYSTEM. g. FURNISH AND INSTALL NOISE SUPPRESSION DIODES ON ALL LOCKS AS CLOSE AS POSSIBLE TO THE LOCK AND AT THE CONTROL RELAY COIL. h. FURNISH AND INSTALL TAMPER SWITCHES ON EACH POWER SUPPLY ENCLOSURE. TAMPER SWITCHES SHALL BE WIRED TO MONITOR POINTS ON THE ACCESS CONTROL PANEL AND SHALL BE CONFIGURED FOR TWENTY-FOUR HOUR ALARM SUPERVISION. i. PROVIDE AND INSTALL CABINET LOCKS ON EACH POWER SUPPLY ENCLOSURE. SECURITY CONTRACTOR TO PROVIDE LOCKS KEYED ALIKE FOR ALL POWER SUPPLY ENCLOSURES. j. CONTRACTOR TO PROVIDE A MACHINE GENERATED LABEL ON THE EXTERIOR OF ALL POWER SUPPLIES AND TRANSFORMERS IDENTIFYING THE EQUIPMENT SERVED. D.ELECTRIFIED LOCKS AND HARDWARE 1. ELECTRIFIED LOCKS, STRIKES, DOOR HARDWARE, “PANIC BAR” EXIT DEVICES AND LOCAL ELECTRIFIED DOOR HARDWARE POWER SUPPLIES TO BE USED IN CONJUNCTION WITH CARD READER ACCESS DOORS SHALL BE FURNISHED AND INSTALLED BY THE DIVISION 8 HARDWARE CONTRACTOR. THE SECURITY CONTRACTOR IS RESPONSIBLE FOR ALL LOW VOLTAGE WIRING AND TERMINATIONS TO ELECTRIFIED LOCKS, ELECTRIFIED DOOR HARDWARE AND ELECTRIC TRANSFER HINGE HARDWARE. a. SEQUENCING, SCHEDULING AND COORDINATING WITH THE DIVISION 8 HARDWARE CONTRACTOR AND THE OWNER IS THE RESPONSIBILITY OF THE SECURITY CONTRACTOR. b. PROGRAMMING, INTERFACING AND TESTING OF SYSTEMS INTEGRATION OF CONTROLLED HARDWARE IS THE RESPONSIBILITY OF THE SECURITY CONTRACTOR. c. PULLING, INSTALLING, DRESSING, TERMINATING AND CONNECTING WIRING TO THE ELECTRIFIED LOCKS AND HARDWARE IS THE RESPONSIBILITY OF THE SECURITY CONTRACTOR. D.SECURITY CONTRACTOR SHALL COORDINATE WITH DIVISION 16 ELECTRICAL CONTRACTOR FOR 120VAC POWER AND INTERFACE OF CONTROLLED HARDWARE WITH THE FIRE ALARM CONTROL PANEL (FACP). E.ALL ELECTRIFIED LOCKS AND HARDWARE USED IN CONJUNCTION WITH CARD READER ACCESS DOORS SHALL BE “FAIL SECURE” UNLESS OTHERWISE NOTED OR REQUIRED BY LAW TO BE “FAIL SAFE”. E.ALARM CONTACTS 1. SECURITY CONTRACTOR TO PROVIDE AND INSTALL GE SENTROL 1076C(D) CONCEALED ALARM CONTACT IN DOOR FRAMES AND CONCEALED MAGNETS IN DOOR LEAFS AT LOCATIONS SHOWN ON THE DRAWINGS INCLUDING ALL DOORS WITH CARD READERS OR EXIT ALARMS. a. CONTACT SHALL CONSIST OF 2 SPDT CONTACTS IN ONE SWITCH. b. CONTACT SHALL HAVE AN ALARM GAP DISTANCE OF NO MORE THAN 1/2 INCH. c. DOOR CONTACTS SHALL BE WIRED NORMALLY CLOSED WITH A 5-STATE SUPERVISION 1K/2K RESISTOR INSTALLED AT THE END-OF-LINE DEVICE. d. CONTACT COLOR SHALL BE PROVIDED TO BEST MATCH DOOR FRAME FINISH. e. CONTACT SHALL NOT BE LARGER THAN 3/4 INCH. f. PAIRS OF DOORS SHALL HAVE ALARM CONTACTS ON EACH DOOR LEAF AND THE ALARM CONTACTS WILL BE WIRED IN A SERIES CIRCUIT. 2. SECURITY CONTRACTOR TO PROVIDE AND INSTALL GE SENTROL 2505A SURFACE-MOUNTED ALARM CONTACT WITH 1092-A ROLL-UP DOOR MOUNTING BRACKET FOR ROLL-UP DOORS AT LOCATIONS SHOWN ON THE DRAWINGS. a. THE CONTACT SHALL HAVE AN ALARM GAP DISTANCE OF NO MORE THAN 2 INCHES. b. DOOR CONTACTS SHALL BE WIRED NORMALLY CLOSED WITH A 5-STATE SUPERVISION 1K/2K RESISTOR INSTALLED AT THE END-OF-LINE DEVICE. c. CONTACT AND MAGNETS SHALL BE IN BRUSHED ANODIZED ALUMINUM TUBE HOUSING AND BE SEALED WITH POLYURETHANE POTTING COMPOUND. d. CONTACT SHALL HAVE 3 FEET OF PERMANENTLY ATTACHED FLEX STAINLESS STEEL CONDUIT. 2.2 WIRE AND CABLE A. WIRE AND CABLE SPECIFICATIONS 1. SECURITY CONTRACTOR SHALL FOLLOW THE MANUFACTURERS' RECOMMENDATION FOR CABLING OR THE MINIMUM REQUIREMENTS OF THE SPECIFICATIONS AND DRAWINGS, WHICHEVER PROVIDES FOR THE MOST STRINGENT REQUIREMENTS. 2. WIRE AND CABLE SIZES, NUMBER OF CONDUCTORS, SHIELDING, OR OTHER DATA LISTED IN THIS SPECIFICATION OR SHOWN ON DRAWINGS ARE A GUIDE TO THE CORRECT PRODUCT REQUIRED TO ACHIEVE A WORKING SYSTEM AND REPRESENT THE MINIMUM ACCEPTABLE EQUIPMENT. 3. CABLES ARE TO BE SHIELDED AS NECESSARY TO PRECLUDE ANY OUTSIDE NOISE OR INTERFERENCE FROM ENTERING THE CABLE AND DEGRADING SYSTEM PERFORMANCE. ALL CABLES SHALL BE U.L. LISTED, AND APPROPRIATE FOR THE APPLICATION. 4. USE PROPER GROUNDING PRACTICES TO ELIMINATE SHORTS, GROUND FAULTS, GROUND LOOPS, RF INTERFERENCE, VOLTAGE FLUCTUATIONS, FOREIGN VOLTAGES AND OPEN CIRCUITS. 5. COORDINATE WITH THE OWNER’S IT DEPARTMENT FOR TELEPHONE LINE REQUIREMENTS AND LOCATION FOR OFF-SITE MONITORING. PROVIDE RJ31X PHONE JACKS FOR TELEPHONE SYSTEM CONNECTIONS. 6. CABLES RUN UNDERGROUND, UNDER SLAB, OR IN SLAB SHALL BE INSTALLED IN CONDUIT AND RATED FOR DIRECT-BURIAL APPLICATION. CABLES ABOVE HARD CEILING OR INACCESSIBLE AREAS SHALL BE INSTALLED IN CONDUIT. STUB UP CONDUITS FROM WITHIN WALLS INTO ACCESSIBLE SPACES. 7. ALL CABLES RUN IN ENVIRONMENTAL AIR HANDLING SPACES SHALL BE PLENUM RATED. PROVIDE PROPER J-HOOKS FOR CABLES NOT RUN IN CONDUIT. CABLES NOT REQUIRED TO BE IN CONDUIT SHALL BE RUN ALONG BUT NOT IN TEL/DATA CABLE TRAYS. 8. ALL CABLE SHALL BE RUN IN UNBROKEN LENGTHS OF 1000 FEET OR LESS. NO COAXIAL OR POWER CABLES LESS THAN 1000 FEET SHALL BE SPLICED. WHEN CABLE CANNOT BE RUN IN UNBROKEN LENGTHS DUE TO CABLE SPOOL LIMITATIONS, SPLICES SHALL BE MADE IN JUNCTION BOXES WITH TERMINAL BLOCKS OR TERMINAL STRIPS AND FORK SPADE LUGS. ALL SPLICES AND JUNCTION BOXES SHALL BE CLEARLY MARKED ON THE “AS-BUILT” RECORD DRAWINGS. 9. ALL WIRE TO WIRE SPLICES NOT UTILIZING TERMINAL BLOCKS OR TERMINAL STRIPS SHALL BE DONE WITH ELECTRICAL TAPE. WIRES SHALL BE INDIVIDUALLY TAPED, THEN NEATLY TAPED TOGETHER TO FORM THE NARROWEST SPLICE POSSIBLE FOR EASE OF INSTALLATION AND REMOVAL, AS WELL AS OVERALL PROTECTION OF THE SPLICE. THE USE OF ALL CRIMP TYPE AND SCREW TYPE CONNECTORS I.E. BEANS, TOP HATS, BUTT CONNECTORS, SNAP CAPS, WIRE NUTS, AND THE “TWIST AND TAPE” METHOD ARE PROHIBITED. 10. ALL END-OF-LINE SUPERVISION RESISTORS SHALL BE INSTALLED AT THE INDIVIDUAL PROTECTION DEVICES, AND NOT IN THE CONTROL PANELS. 11. ALL 24VAC POWER CABLING SHALL BE OF STRANDED CONSTRUCTION. FOR CONNECTIONS REQUIRING PRESSURE CAPTIVE CONNECTION, WIRE SHALL BE SOLDER TINNED PRIOR TO INSERTION INTO PRESSURE CONNECTORS. 12. WIRING SHALL BE GROUPED AND HARNESSED TO FACILITATE ACCESS TO ALL EQUIPMENT, AS WELL AS MAINTENANCE AND REPLACEMENT OF EQUIPMENT. 13. ALL CABLE SHALL BE LABELED AT ORIGIN AND TERMINATION, REFERENCING TO A MASTER LEGEND SCHEDULE AS SHOWN ON “AS- BUILT” RECORD DRAWINGS. LABELING AND ANY SPLICE LOCATIONS SHALL BE NOTED ON “AS-BUILT” RECORD DRAWINGS. ALL LABELS SHALL BE DONE USING MACHINE GENERATED CABLE TAGS IN THE “FLAGGED” POSITION. HAND WRITTEN LABELS ARE NOT ACCEPTABLE 14. CABLING SHALL BE SIZED AND INSTALLED ACCORDING TO CALIFORNIA ELECTRIC CODE REQUIREMENTS. 15. ANY CABLING OR RACEWAY EXPOSED TO WEATHER SHALL BE RATED F OR THAT USE. 16.STUB UP CONDUITS FROM OUTLETS INTO ACCESSIBLE SPACES. CABLES SHALL BE RUN WITH BUT NOT IN THE TEL/DATA CABLE TRAY. MIXING OF SECURITY LOW VOLTAGE CABLES WITH TEL/DATA CABLES WILL NOT BE PERMITTED. UTILIZE APPROVED CLIPS OR MOUNTING TO SECURELY MOUNT SECURITY CABLE TO THE RACK FRAMEWORK OR HANGERS. 17.CABLE NOT RUN WITH THE CABLE TRAY SHALL BE RUN ALONG THE WALL USING J-HOOK HANGERS. HANGERS SHALL BE SUFFICIENT TO PROPERLY SUPPORT CABLE. 18.CABLING SHALL BE WEST PENN, BELDEN, WINDY CITY WIRE OR APPROVED EQUAL. 19.ALL FINAL LABELING SHALL BE WITH MACHINE-GENERATED PRINTED LABELS, SPECIFICALLY MADE FOR CABLE LABELING. NO HANDWRITTEN LABELS WILL BE ACCEPTED. ALL WIRING INCLUDING POWER CORDS AND FEEDS, NETWORK CONNECTIONS, AND SYSTEM CABLING SHALL BE FITTED WITH A MACHINE GENERATED LABEL IDENTIFYING THE DEVICE OR POINT SERVED. THE ID MARKER FOR EACH LABEL SHALL HAVE THE DEVICE NUMBER AND NAME. 20.EACH ENCLOSURE SHALL HAVE A SECURITY AS-BUILT DRAWING WITH POINT LIST AND NAMING / NUMBERING TO MATCH THE MACHINE GENERATED LABELING ON CABLES TERMINATED TO THE PANELS AND POWER SUPPLIES. PART 3 - EXECUTION 3.1 REQUIREMENTS A. SYSTEMS SHALL BE COMPLETE AND OPERATIONAL IN ALL RESPECTS. B.SECURITY CONTRACTOR SHALL FURNISH AND INSTALL ALL EQUIPMENT FOR ALL BUILDING SECURITY SYSTEMS. C.WIRING AND CONDUIT SHOWN ON DRAWINGS REPRESENTS A MINIMUM REQUIREMENT. SECURITY CONTRACTOR SHALL FURNISH AND INSTALL ALL WIRING RECOMMENDED BY SUBMITTED SYSTEM MANUFACTURERS FOR OPTIMUM SYSTEM PERFORMANCE AT NO INCREASE IN CONTRACT PRICE. D.ALL WALL, FLOOR, AND CEILING PENETRATIONS, REGARDLESS OF THE FIRE RATING OF THE PARTITION, MUST BE PROPERLY SLEEVED WITH CONDUIT AND PROPERLY SEALED USING APPROVED FIRE STOPPING MATERIALS AND SEALANTS. E.CONNECT POWER TO SECURITY SYSTEMS AS REQUIRED AND COORDINATE WITH THE DIVISION 16 ELECTRICAL CONTRACTOR. F.ALL SECURITY EQUIPMENT, JUNCTION BOXES, AND TERMINAL CANS INSTALLED IN PUBLIC ACCESSIBLE AREAS SHALL BE INSTALLED UTILIZING TAMPER PROOF MOUNTING HARDWARE. PROVIDE A MINIMUM OF TWO DRIVER BITS OR HAND TOOLS TO THE OWNER’S REPRESENTATIVE FOR EACH TYPE AND SIZE OF SECURITY FASTENER PROVIDED. G.PROVIDE SEISMIC RESTRAINT FOR ALL EQUIPMENT, INCLUDING EQUIPMENT RACKS AND CONSOLES. H.SECURITY CONTRACTOR SHALL PROVIDE THE OWNER WITH A MINIMUM OF FOUR COMPLETE SETS OF KEYS FOR ALL EQUIPMENT INSTALLED IN THIS PROJECT PRIOR TO THE CLOSE OF THE PROJECT. ALL KEYS RELATING TO THE SECURITY SYSTEMS SHALL BE KEPT SEPARATE FROM THE BUILDING SYSTEMS AND DELIVERED TO THE OWNER’S REPRESENTATIVE. 3.2 RECORD DRAWINGS A. MAINTAIN A COMPLETE SET OF “AS-BUILT” RECORD DRAWINGS UPDATED WITH MARK-UPS INSERTED AS THE WORK IS PERFORMED. AS WORK IS INSTALLED CAREFULLY MARK ON “AS-BUILT” RECORD DRAWINGS IN COLORED PENCIL THE CORRECT LOCATION OF ALL WORK INCLUDING DEPTH OF UNDERGROUND RUNS AND CONCEALED WORK WITH THEIR DIMENSIONS FROM CLEARLY IDENTIFIED POINTS ON PERMANENT BUILDINGS, FIXTURES, WALLS, OR WALKS. WIRING DIAGRAMS, RISERS AND DETAILS SHALL BE INCLUDED. B.UPON COMPLETION OF THE PROJECT TRANSFER HAND-DRAWN INFORMATION TO CAD DRAWINGS THEN COPY UPDATED CAD DRAWINGS ONTO COMPACT DISC AND SUBMIT TO THE OWNER, ARCHITECT AND SECURITY CONSULTANT. NO HAND-DRAWN “AS-BUILT” RECORD DRAWINGS WILL BE ACCEPTED. C.“AS-BUILT” RECORD DRAWINGS SHALL BE PROVIDED IN FOUR PLOTTED SETS AS WELL AS ONE SET OF CAD DRAWINGS ON COMPACT DISC TO THE OWNER, ARCHITECT AND SECURITY CONSULTANT. ONE ADDITIONAL COMPLETE HALF-SIZE PLOTTED SET SHALL REMAIN ON THE PROJECT SITE IN FOLDERS SECURED INSIDE THE ELECTRONIC RACKS. 3.3 TESTS AND REPORTS A. PERFORM SYSTEMS TESTS USING PERSONNEL WHO HAVE ATTENDED A MANUFACTURER'S TRAINING SCHOOL FOR INSTALLATION AND TESTING OF THE SYSTEMS AS DESCRIBED ABOVE. PERFORM TESTING WITH THE TEST INSTRUMENTS AS REQUIRED BY THE MANUFACTURER; TESTING BY MEANS OTHER THAN THE MANUFACTURER'S PROCEDURES WILL NOT BE ACCEPTABLE UNLESS AGREED TO BY THE OWNER, ARCHITECT, SECURITY CONSULTANT AND MANUFACTURER. B.THE SECURITY CONTRACTOR SHALL TEST THE FOLLOWING SYSTEM AND DOCUMENT THESE TESTS FOR THE OWNER, ARCHITECT AND SECURITY CONSULTANT PRIOR TO FINAL COMMISSIONING; 1. CARD READERS a. THE CARD READER LED IS RED WHEN THE DOOR IS SECURE. b. THE CARD READER LED IS SOLID GREEN WHEN THE DOOR IS PLACED IN AN UNLOCKED MODE. c. THE CARD READER BEEPS AND THE LED FLASHES GREEN AND WHEN A VALID CARD IS PRESENTED. d. THE CARD READER WILL READ THE ACCESS CARDS AS SPECIFIED FOR THIS PROJECT WHEN PRESENTED TO THE READER AT THE RANGE AS SPECIFIED BY THE MANUFACTURER. e. THE CARD READER PRODUCES AN OFFLINE SIGNAL ON THE SYSTEM WHEN POWER OR COMMUNICATION TO THE READER IS LOST. f. THE CARD READER WILL PRODUCE ALARMS FROM DENIED ACCESS AND EXPIRED CARDS ON THE SYSTEM. 2. DOOR ALARM CONTACT a. THE CONTACT IS FREE FROM FAULTS AND TROUBLE CONDITIONS. b. THE CONTACT PRODUCES A DOOR FORCED OPEN ALARM ON THE SYSTEM WHEN THE DOOR IS OPENED WITHOUT A VALID CARD READ OR WITH A KEY. c. THE CONTACT PRODUCES A DOOR HELD OPEN ALARM ON THE SYSTEM 15 SECONDS FOR PERIMETER DOORS AND 30 SECONDS FOR INTERIOR DOORS AFTER THE DOOR IS OPENED. 3. REQUEST-TO-EXIT a. THE REQUEST-TO-EXIT IS FREE FROM FAULTS AND TROUBLE CONDITIONS. b. THE REQUEST-TO-EXIT SHUNTS THE DOOR ALARM CONTACT UPON ACTIVATION FROM A USER EXITING THE ROOM. c. THE REQUEST-TO-EXIT BEEPS WHEN A HELD OR FORCED OPEN ALARM IS CREATED ON THE CORRESPONDING DOOR. 4. ELECTRIFIED HARDWARE a. THE ELECTRIFIED HARDWARE UNLOCKS WHEN A VALID CARD IS PRESENTED TO THE CORRESPONDING READER. b. THE ELECTRIFIED HARDWARE UNLOCKS WHEN AN UNLOCK COMMAND IS SENT FROM THE SYSTEM. c. THE ELECTRIFIED HARDWARE STAYS UNLOCKED FOR A MAXIMUM OF 10 SECONDS ON PERIMETER DOORS AND 20 SECONDS ON INTERIOR DOORS AFTER A VALID CARD IS PRESENTED. FAILURE TO OPEN THE DOOR WITHIN THE STATED TIME WILL RESULT IN RELOCKING OF THE DOOR. d. THE ELECTRIFIED HARDWARE RE-LOCKS AFTER A VALID CARD IS PRESENTED AND THE DOOR IS OPENED. 5. ALARM CONTACTS a. THE ALARM CONTACT IS FREE FROM FAULTS AND TROUBLE CONDITIONS. B.THE ALARM CONTACT GENERATES AND ALARM ON THE SYSTEM WHEN THE ASSOCIATED DOOR IS OPENED WITHIN THE SPECIFIED GAP DISTANCE. C.THE ALARM CONTACT GENERATES A RESET OR CLEAR ALARM ON THE SYSTEM WHEN THE DOOR IS CLOSED AND LATCHED. D.THE ALARM CONTACT DOES NOT PRODUCE ALARMS ON THE SYSTEM WHEN THE DOOR IS SHUT AND MOVED BACK AND FORTH INSIDE THE FRAME. C.UPON COMPLETION OF THE INSTALLATION OF THE SECURITY SYSTEMS SECURITY CONTRACTOR SHALL SUBMIT WRITTEN REPORTS INCLUDING BUT NOT LIMITED TO THE FOLLOWING INFORMATION: 1. A COMPLETE LIST OF ALL EQUIPMENT INSTALLED INCLUDING SERIAL NUMBERS OF MAJOR COMPONENTS. 2. CERTIFICATION THAT ALL EQUIPMENT IS PROPERLY INSTALLED, PROGRAMMED, FUNCTIONAL, 100 PERCENT OPERATIONAL AND CONFORMS TO SPECIFICATIONS AND DRAWINGS. 3. TEST REPORTS OF ALL ZONES, DEVICES, AND EQUIPMENT. 4. TEST TECHNICIAN'S NAME, COMPANY AND DATE OF TEST. END OF SECTION R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:23:32 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) G0-05 SPECIFICATIONS CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 CR CR RE X T ACCESSIBLE PATH OF TRAVEL (E) INTERNATIONAL SYMBOL OF ACCESSIBILITY PAINTED ON THE PAVED SURFACE OF EACH ACCESSIBLE PARKING STALL (E) 1-HR RATED FIRE BARRIER FOR SHAFTS PER CBC 407.4.3 GROUP I-2 CARE SUITES, 707 FIRE BARRIERS, 707.3.9 SEPERATED OCCUPANCIES 45 MIN OPENINGS PER TABLE 716.5 10 9 8 7 6 5 4 1 3 L M N P QABCDEFGHJK 2 1 03 G1-00 1 1 2 3 4 5 5 5 5566 7 8 9 9 4 2 NOT APPLICABLE CBC 2022: FIGURE 11B-703.7.2.1 - INTERNATIONAL SYMBOL OF ACCESSIBILITY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL COMPLY WITH FIGURE 11B-703.7.2.1 THE SYMBOL SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE COLOR BLUE SHALL APPROXIMATE FS 15090 IN FEDERAL STANDARD 595C. EXCEPTIONS: 1. THE APPROPRIATE ENFORCEMENT AGENCY MAY APPROVE OTHER COLORS PROVIDED THE SYMBOL CONTRAST IS LIGHT ON DARK OR DARK ON LIGHT. 2. ON ACCESSIBILITY FUNCTION BUTTON ON HALL CALL CONSOLES IN A DESTINATION-ORIENTED ELEVATOR SYSTEM THE INTERNATIONAL SYMBOL ACCESSIBILITY SHALL BE A WHITE SYMBOL ON A BLACK BACKGROUND.FIGURE 11B-308.2.1 UNOBSTRUCTED FORWARD REACH 1' - 3 " M I N . 4' - 0 " M A X . (a) 4' - 0 " M A X . 1' - 8" MAX. (b) 3' - 8 " M A X . >20"- 2' - 1" MAX. 10" MAX. 1' - 3 " M I N . 4' - 0 " M A X . FIGURE 11B-308.3.1 UNOBSTRUCTED SIDE REACH (a) 2' - 1 0 " M A X . 4' - 0 " M A X . 10" MAX. FIGURE 11B-308.3.2 OBSTRUCTED HIGH SIDE REACH (b) 2' - 1 0 " M A X . 3' - 1 0 " M A X . > 10"- 2' - 0" MAX. FIGURE 11B-308.2.2 OBSTRUCTED HIGH FORWARD REACH 10/ G1-00 15 / G 1 -00 20 / G 1 -00 25/ G1-00 1518 TOILET/LAV, GENERAL TLGEN 1' - 1 1 5 / 8 " 4' - 8" 5' - 0 " 3' - 6"1' - 0" 8" 1' - 6 " 2' - 9 " 1' - 8 " 14 15 16 1' - 6 " 2' - 9 " 3' - 4 " 10 11 13 2' - 1 0 " 3' - 0" 1' - 0"2' - 0" 1415 1' - 6" 1094 3' - 2 3 / 4 " 2' - 1 0 " 10 11 12 N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 7/3/2024 8:08:48 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) G1-00 PLAN - SITE ACCESSIBLITY CA361 1 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 GENERAL NOTES SHEET KEYNOTES LEGEND 1/16" = 1'-0"PLAN - SITE ACCESSIBILITY 01 N N/AINTERNATIONAL SYMBOL OF ACCESSIBILITY 02NTSREACH RANGES 09 1/2" = 1'-0"PLAN - 1518 (E) ACCESSIBLE TOILET/ LAV 031/2" = 1'-0"RM 1518 - NORTH ELEVATION 101/2" = 1'-0"RM 1518 - EAST ELEVATION 151/2" = 1'-0"RM 1518 - WEST ELEVATION 201/2" = 1'-0"RM 1518 - SOUTH ELEVATION 25 1 (E) ACCESSIBLE PUBLIC ENTRANCE. (COMPLIES WITH 11B-404) 2 (E) ACCESSIBLE ROUTE FROM THE PUBLIC WAY TO THE BUILDING ENTRANCE. 3 (E) PUBLIC WAY. 4 (E) "UNATHORIZED VEHICLES" WARNING SIGN AT PARKING AREA ENTRANCE (COMPLIES WITH CBC 11B-502.8.2) 5 (E) ACCESSIBLE PARKING (COMPLIES WITH CBC 11B-208) 6 (E) VAN ACCESSIBLE PARKING (COMPLIES WITH CBC 11B-502) 7 (E) DETECTABLE WARNING SURFACE (COMPLIES WITH 11B-247) 8 (E) DROP OFF AREA 9 (E) AMBULANCE PARKING 10 (E) ACCESSIBLE LAVATORY WITH ADA PIPE WRAP AND KNEE CLEARANCE PER CBC 11B-606. 11 (E) SOAP DISPENSER. 12 (E) PAPER TOWEL DISPENSER. 13 (E) MIRROR. 14 (E) WALL HUNG TOILET. 15 (E) TOILET PAPER DISPENSER. 16 (E) TOILET SET COVER DISPENSER. KEY PLAN CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 PLAN CHECK CORRECTIONS 07/02/2024 1900 E 4th St - 1011190678/9/2024 CR T EGRESS PATH OF TRAVEL TRAVEL DISTANCE / COMMON PATH OF TRAVEL EXIT ACCESS TRAVEL DISTANCE (CBC TABLE 1017.2) I-2 = 200'-0" B = 300'-0" COMMON PATH OF EGRESS TRAVEL (CBC 1006.2.1) I-2 = 75'-0" B = 100'-0" TD: CPT: 200'-0" 75'-0" (E) 1-HR RATED FIRE BARRIER FOR SHAFTS PER CBC 407.4.4 GROUP I-2 AND I-2.1 CARE SUITES, 707 FIRE BARRIERS, 707.3.9 SEPERATED OCCUPANCIES 45 MIN OPENINGS PER TABLE 716.5 (E) NON-RATED PARTITION Area Name 150 SF A-1 300 100 OCC AREA TAG AREA OCCUPANCY GROUP / OCCUPANT LOAD FACTOR NUMBER OF OCCUPANTS EXIT SIGN NON-RATED CORRIDOR PER CBC 1020.2 B-OCCUPANCY FULLY SPRINKLERED PER TABLE 1020.2 EGRESS DOOR TAG NUMBER OF OCCUPANTS PROVIDED EGRESS WIDTH REQUIRED EGRESS WIDTH 100 33"34" 10 9 8 7 6 5 4 1 3 L M N P QABCDEFGHJK 2 CONFERENCE ROOMS PEDIATRICS OBSTETRICS / GYNECOLOGY PEDIATRICS RADIOLOGY - GENERAL BLOOD DRAW LAB MHW MENTAL HEALTH/ PSYCHIATRY MEDICAL OFFICE ADMINISTRATION O/P PHARMACY PRIMARY CARE FAMILY MEDICINE MEMBER SERVICE CENTER MEDICAL OFFICE ADMINISTRATION MEDICAL OFFICE ADMINISTRATION MATERIAL MGMT-ADMIN ENVIRONMENTAL SERVICES ENVIRONMENTAL SERVICES ENVIRONMENTAL SERVICES OBSTETRICS / GYNECOLOGY 2 2 1 3 3 TD: CPT: 133' - 6" 23' - 8" TD: CPT: 205' - 6" 15' - 6"4,223 SF MEDICAL OFFICES B 150 29 OCC 32"66" 20 70" 32"34" 20 32"70" 7 32"70" 7 7 32"39" 32"34" 9 1,045 SF MEDICAL OFFICES B 150 7 OCC MEANS OF EGRESS: 1. PROVIDE ILLUMINATED EXIT SIGN AND TACTILE EXIT SIGN AT EACH EXIT ACCESS DOOR WITHIN THE HALLWAY WHERE REQUIRED TWO MEANS OF EGRESS. 2. FOR THE PURPOSE OF SECTION 1013.4, THE TERM "TACTILE EXIT SIGNS" SHALL MEAN THOSE REQUIRED SIGNS THAT COMPLY WITH CHAPTER 11B, SECTION 11B-703.1, 11B-703.2, 11B-703.3 OR 11B-703.5 3. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL OF NOT LESS THAN ONE-CANDLE AT THE WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. 4. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED AT ALL TIMES. EXTERNALLY ILLUMINATED EXIT SIGNS SHALL BE CONNECTED TO AN EMEGRENCY POWER SYSTEM (BATTERIES, UNIT EQUIPMENT OR AN IN-SITE GENERATOR) THAT WILL AUTOMATICALY ILLUMINATE THE EXIT SIGN FOR A DURATION OF NOT LESS THAN 90 MINUTES IN CASE OF PRIMARY POWER LOSS. N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 7/3/2024 8:08:59 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) G1-11 PLAN - CODE ANALYSIS 1ST FLR CA361 1 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 GENERAL NOTES SHEET KEYNOTES LEGEND 1/16" = 1'-0"PLAN - CODE ANALYSIS 1ST FLR 01 N 1 EXISTING TACTILE SIGN "EXIT" 2 EXISTING TACTILE SIGN "EXIT ROUTE" 3 (N) TACTILE SIGN "EXIT ROUTE" SEE SHEET SG5-01 FOR ADDITIONAL INFORMATION. KEY PLAN CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 PLAN CHECK CORRECTIONS 07/02/2024 1900 E 4th St - 1011190678/9/2024 CR CR CR IC 10 9 8 7 6 5 4 1 3 L M N P Q A B C D E F G H J K 2 CONFERENCE ROOMS PEDIATRICS OBSTETRICS / GYNECOLOGY PEDIATRICS RADIOLOGY - GENERAL BLOOD DRAW LAB MHW MENTAL HEALTH/ PSYCHIATRY MEDICAL OFFICE ADMINISTRATION O/P PHARMACY PRIMARY CARE FAMILY MEDICINE MEMBER SERVICE CENTER MEDICAL OFFICE ADMINISTRATION MEDICAL OFFICE ADMINISTRATION MATERIAL MGMT-ADMIN ENVIRONMENTAL SERVICES ENVIRONMENTAL SERVICES ENVIRONMENTAL SERVICES OBSTETRICS / GYNECOLOGY 01 A0-13 1507 IMAMO 1509 SGENL 1529 EVSRM 1506 IGENL 1617 OPROV 1504A VESTI 1518 TLGEN 1517 TLGEN 1514 WSGEN 1513 DRSSA 1505 SHELL 1108 TRASH 1105 SLINC 1014 OPROV 1013 WSGEN 1012 EXROM 1011 OPROV 1104 HALLW 1015 EXROM 1017 WSGEN 1310W01 WSGEN 1018 WSGEN 1010 EXROM 1009 EXROM 1150 HALLW 1109 EQRTR 1107A SGENL 1103 SEQGN 1102 WRGEN 1016 EXROM 1019 EXROM1008 EXROM 1154A SCLOS 1101 CORRD 1020 TLSTF1007 EXROM 1153A VESTI 1153 SGENL 1154 TLPUB 1155 TLPUB 1150B ADRFT 1021 TLPAT 1033 EQELC 1030 HALLW 1211 CONFR 1213 UTILC 1214 EXROM 1224 TLSTF 1215 AMENR1024 UTILC 1022 PRMIN 1023 UTILS 1006 OPROV 1005 EXROM 1209 HALLW 1025 AMENR 1029 HALLW 1004 EXROM 1203 OPROV 1217 WACPF 1216 OGENL 1223 EXROM 1026 AAMEN1003 WACPF 1204 OPROV 1217W01 WSGEN 1217W02 WSGEN 1217W03 WSGEN 1217W04 WSGEN 1217W05 WSGEN 1217W06 WSGEN 1210 HALLW 1027 WSGEN1002 OGENL 1028 WSGEN 1200 WTAGN 1222 EXROM 1221 EXROM 1220 EXROM 1218 UTILS 1300 CORRD 1001 WTAGN 1219 MEDPR 1201 RECEP 1212 HALLW 1206 EXROM 1207 EXROM 1208 EXROM 1202 SGENL 1312 WAGEN 1312W01 WSGEN 1301 WTAGN 1302 RECEP 1311B WACPF 1311A WACPF 1311 HALLW 1316 WTAGN1310 RECEP 1315 OGENL 1314 OGENL 1313 OGENL 102 WSGEN 1406 SMEDS 1408 OGENL 1407 OGENL 1409 EQMEC 1410 EQELV 1405 SGENL 1500 COORD 1404 TLSTF 1403 WADIS 1401 WTAGN 1402 CONSR 1205 OPROV 1031 HALLW 1411 EQMEC 1498 ATELE 1499 OGENL 1501 LOBBY EL01 ELEVA 1528 SEQGN 1527 OGENL 1535 SSUPP 1502 CORRD 1616 EXROM 1620 WSGEN 1621 WSGEN 1622 TLPUB 1623 WSGEN 1624 AGENL 1625 EXROM 1630 EXROM 1626 EXROM 1627 EXROM 1628 OGENL 1629 TLGEN 1615 EXROM 1614 EXROM 1613 OPROV 1612 EXROM 1611 EXROM 1610 OPROV 1609 OPROV 1608 UTILC 1608A WSGEN 1602 HALLW 1605 EXROM 1606 EXROM 1607 EXROM 1808 TLPUB 1809 CORRD 1810 SGENL 1807 SGENL 1805 CONFR 1800A CORRD 1800 CORRD 1804 LNGST 1802 KITCH 1801 EVSRM 1800C VESTI 1706 EXROM 1707 EXROM 1708 UTILS 1704 HALLW 1704A UTILG 1726 OPROV 1711 EXROM 1709 PRMIN 1601 HALLW 1600 HALLW 1710 OGENL 1712 EXROM 1713 WSGEN 1714 WSGEN 1715 WRGEN 1716 TLPUB 1717 WSGEN 1718 WSGEN 1725 EXROM 1724 OPROV 1723 EXROM 1722 OPROV 1721 EXROM 1720 OPROV 1719 EXROM 1531 LNGST 1530 WAGEN 1532 OBSRM 1536 VESTI 1538 TLPTS 1534 LBTRY 1533 BLDDR 1537 TLPTS 1534B BLDDR 1534C BLDDR 1534D BLDDR 1701 WTAGN 1702 RECEP 1703 WTAGN 1604 WTAGN 1800B VESTI 1803 TLPUB 1705 HALLW 1507A DRSSA NOT APPLICABLE AREA OF WORK (E) PARTITION DEPARTMENT BOUNDRY DEMO PARTITION NOT APPLICABLE GENERAL NOTES N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:21:15 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A0-11 PLAN - DEMO OVERALL 1ST FLR CA361 1 1 - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 GENERAL NOTES SHEET KEYNOTES LEGEND 1/16" = 1'-0"PLAN - DEMO OVERALL 1ST FLR 01 N KEY PLAN CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 C CC C PA PA 10 9 8 7 6 5 4 1 3 L M N P Q A B C D E F G H J K 2 CONFERENCE ROOMS PEDIATRICS OBSTETRICS / GYNECOLOGY PEDIATRICS RADIOLOGY - GENERAL BLOOD DRAW LAB MHW MENTAL HEALTH/ PSYCHIATRY MEDICAL OFFICE ADMINISTRATION O/P PHARMACY PRIMARY CARE FAMILY MEDICINE MEMBER SERVICE CENTER MEDICAL OFFICE ADMINISTRATION MEDICAL OFFICE ADMINISTRATION MATERIAL MGMT-ADMIN ENVIRONMENTAL SERVICES ENVIRONMENTAL SERVICES ENVIRONMENTAL SERVICES OBSTETRICS / GYNECOLOGY 03 A0-13 1108 TRASH 1105 SLINC 1014 OPROV 1013 WSGEN 1012 EXROM 1011 OPROV 1104 HALLW1015 EXROM1017 WSGEN 1310W01 WSGEN 1018 WSGEN 1010 EXROM 1009 EXROM 1150 HALLW 1109 EQRTR 1107A SGENL 1103 SEQGN 1102 WRGEN 1016 EXROM1019 EXROM 1008 EXROM 1154A SCLOS 1101 CORRD1020 TLSTF 1007 EXROM 1153A VESTI 1153 SGENL 1154 TLPUB 1155 TLPUB 1150B ADRFT 1021 TLPAT1033 EQELC 1030 HALLW 1211 CONFR 1213 UTILC 1214 EXROM 1224 TLSTF 1215 AMENR1024 UTILC 1022 PRMIN 1023 UTILS 1006 OPROV 1005 EXROM 1209 HALLW 1025 AMENR 1029 HALLW 1004 EXROM 1203 OPROV 1217 WACPF 1216 OGENL 1223 EXROM 1026 AAMEN 1003 WACPF 1204 OPROV 1210 HALLW 1027 WSGEN1002 OGENL 1028 WSGEN 1200 WTAGN 1222 EXROM 1221 EXROM 1220 EXROM 1218 UTILS 1300 CORRD 1001 WTAGN 1219 MEDPR 1201 RECEP 1212 HALLW 1206 EXROM 1207 EXROM 1208 EXROM 1202 SGENL 1312 WAGEN 1312W01 WSGEN 1301 WTAGN 1302 RECEP 1311B WACPF 1311A WACPF 1311 HALLW 1316 WTAGN1310 RECEP 1315 OGENL 1314 OGENL 1313 OGENL 102 WSGEN 1406 SMEDS 1408 OGENL 1407 OGENL 1409 EQMEC 1410 EQELV 1405 SGENL 1500 COORD 1404 TLSTF 1403 WADIS 1401 WTAGN 1402 CONSR 1205 OPROV 1031 HALLW 1411 EQMEC 1498 ATELE 1499 OGENL 1501 LOBBY EL01 ELEVA 1528 SEQGN 1529 EVSRM 1527 OGENL 1535 SSUPP 1509 SGENL 1507 IMAMO 1506 IGENL 1513 DRSSA 1502 CORRD 1514 WSGEN 1517 TLGEN 1518 TLGEN 1505 SHELL 1504A VESTI 1617 OPROV 1616 EXROM 1620 WSGEN 1621 WSGEN 1622 TLPUB 1623 WSGEN 1624 AGENL 1625 EXROM 1630 EXROM 1626 EXROM 1627 EXROM 1628 OGENL 1629 TLGEN 1615 EXROM 1614 EXROM 1613 OPROV 1612 EXROM 1611 EXROM 1610 OPROV 1609 OPROV 1608 UTILC 1608A WSGEN 1602 HALLW 1605 EXROM 1606 EXROM 1607 EXROM 1808 TLPUB 1809 CORRD 1810 SGENL 1807 SGENL 1805 CONFR 1800A CORRD 1800 CORRD 1804 LNGST 1802 KITCH 1801 EVSRM 1800C VESTI 1706 EXROM 1707 EXROM 1708 UTILS 1704 HALLW 1704A UTILG 1726 OPROV 1711 EXROM 1709 PRMIN 1601 HALLW 1600 HALLW 1710 OGENL 1712 EXROM 1713 WSGEN 1714 WSGEN 1715 WRGEN 1716 TLPUB 1717 WSGEN 1718 WSGEN 1725 EXROM 1724 OPROV 1723 EXROM 1722 OPROV 1721 EXROM 1720 OPROV 1719 EXROM 1531 LNGST 1530 WAGEN 1532 OBSRM 1536 VESTI 1538 TLPTS 1534 LBTRY 1533 BLDDR 1537 TLPTS 1534B BLDDR 1534C BLDDR 1534D BLDDR 1701 WTAGN 1702 RECEP 1703 WTAGN 1604 WTAGN 1800B VESTI 1803 TLPUB 1705 HALLW 1. U.N.O., DEMO EXISTING CEILING TILES, T-BAR, SUPPORT SYSTEM, AND UNISTRUT SYSTEM IN ROOM 1505. 2. U.N.O., DEMO ALL CEILING LIGHT FIXTURES, HVAC REGISTERS/ DIFFUSERS LOCATED IN CEILINGS INDICATED AS DEMO. NOT APPLICABLE AREA OF WORK (E) PARTITION DEPARTMENT BOUNDRY DEMO PARTITION N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:21:36 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A0-12 PLAN - DEMO OVERALL RCP 1ST FLR CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 GENERAL NOTES SHEET KEYNOTES LEGEND 1/16" = 1'-0"PLAN - DEMO OVERALL RCP 1ST FLR 01 N KEY PLAN CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 J 1 EP O EPO D D D D PS CR CR CR IC C CC C PA PA C 2.7 2.5 2.3 1.4 F G H J K 1529 ENVIRONMENTAL SERVICES CLOSET EVSRM 1509 STORAGE, GENERAL SGENL 1507 IMAGING, MAMMOGRAPHY IMAMO 1502 CORRIDOR CORRD 1517 TOILET/LAV, GENERAL TLGEN 1518 TOILET/LAV, GENERAL TLGEN 1617 OFFICE, PROVIDER OPROV 1602 HALLWAY HALLW 1701 WAITING AREA, GENERAL WTAGN 1507A ACCESSIBLE DRESSING BOOTH DRSSA 1 2 3 4 5 6 7 4 4 3 3 3 3 3 2 1 67 7 6 4 4 4 1 4 8 9 6 6 10 11 11 12 12 4 11 7 13 14 14 14 14 16 16 1717 186 16 19 19 19 19 20 10 21 22 61 23 28 24 27 25 26 1515 DRESSING ROOM DRESSB 1516 DRESSING ROOM DRSSB 19 32 1512 DRESSING BOOTH DRSSB 15 20 20 11 20 1510 SUBWAIT ROOM 14 1508 HALLWAY HALLW 36 36 36 36 36 36 36 36 36 36 37 38 39 40 41 42 WORK AREA, TECHNICIAN WATEC 1506 IMAGING GENERAL IGENL 1505 VESTIBULE VESTI 1504A HALLWAY HALLW 1504 ACCESSIBLE DRESSING BOOTH DRSSA 1513 VESTIBULE VESTI 1511 DRESSING BOOTH DRSSB 1514 32 45 45 16 43 44 44 49 48 16 NOT APPLICABLE GENERAL NOTES F G H J K 2 1501 LOBBY LOBBY 1529 ENVIRONMENTAL SERVICES CLOSET EVSRM 1509 STORAGE, GENERAL SGENL 1507 IMAGING, MAMMOGRAPHY IMAMO 1502 CORRIDOR CORRD 1517 TOILET/LAV, GENERAL TLGEN 1518 TOILET/LAV, GENERAL TLGEN 1617 OFFICE, PROVIDER OPROV 1602 HALLWAY HALLW 1701 WAITING AREA, GENERAL WTAGN 1507A ACCESSIBLE DRESSING BOOTH DRSSA 29 30 1515 DRESSING ROOM DRESSB1516 DRESSING ROOM DRSSB 33 33 303030 30 30 30 30 30 34 35 (E) +9' - 5"AFF (E) +9' - 0"AFF (E) +9' - 0"AFF (E) +8' - 0"AFF(E) +8' - 0"AFF (E) +8' - 0"AFF (E) +9' - 0"AFF (E) +8' - 0"AFF (E) +9' - 0"AFF (E) +9' - 0"AFF SUBWAIT ROOM 1510 HALLWAY HALLW 1508 HALLWAY HALLW 1504 VESTIBULE VESTI 1504A DRESSING BOOTH DRSSB 1512 VESTIBULE VESTI 1511 ACCESSIBILE DRESSING BOOTH DRSSA 1513 DRESSING BOOTH DRSSB 1514 IMAGINE GENERAL IGENL 1505 WORK AREA, TECHNICIAN WATEC 1506 31 46 46 46 46 46 47 (E) +8' - 0"AFF DEMOLITION OF NON-RATED PARTITION AREA OF WORK (E) +1'-0"AFF CEILING HEIGHT TAG DEMO T-BAR CEILING DEMO GYP. BD. CEILING (E) 1-HR RATED FIRE PARTITION (CORRIDORS) PER CBC 708 FIRE PARTITIONS 20 MIN OPENINGS PER TABLE 716.5 (E) NON-RATED PARTITION DEMO DIFFUSERS / REGISTERS DEMO RECESSED LIGHT FIXTURE DEMO RECESSED SPEAKER DEMO WALL MOUNTED NURSE CALL LIGHT & PULL STRING DEMO FIRE ALARM DEVICE (DEFERRED APPROVAL) DEMO EXIT SIGN DEMO FIRE SPRINKLER EXTENT OF (E) FLOOR FINISH DEMO N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:21:44 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A0-13 PLAN - DEMO 1ST FLR CA361 1 01 - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 SHEET KEYNOTES LEGEND 1/4" = 1'-0"PLAN - DEMO 1ST FLR 01 N 1/4" = 1'-0"PLAN - DEMO RCP 1ST FLR 03 1 REMOVE (E) SINK AND/OR COUNTER. SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 2 REMOVE (E) COMPUTER WORK STATION. 3 REMOVE (E) CHAIR. 4 REMOVE (E) WASTE RECEPTACLE. 5 REMOVE (E) WORKSTATION PRINTER. 6 REMOVE ALL (E) BASE AND UPPER CABINET. 7 REMOVE (E) WALL MOUNTED BOARD. 8 REMOVE (E) CR READER MACHINE. 9 REMOVE (E) SHELF CABINET. 10 REMOVE (E) WORKSTATION. 11 REMOVE (E) WALL MOUNTED SOAP OR DEGERMER. 12 REMOVE (E) WALL MOUNTED GLOVE DISPENSER. 13 DEMO (E) PONY WALL. 14 REMOVE (E) CORNER GUARDS. 15 DEMO (E) LEAD-LINED DOOR 16 DEMO (E) NURSE CALL LIGHT AND PULL STRING. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 17 REMOVE (E) DRESSING RM BENCH. 18 REMOVE (E) DRESSING RM CASEWORK. 19 DEMO (E) WALL. 20 EXTENT OF (E) FLOOR DEMO. 21 REMOVE (E) BUCKY WALL STAND. 22 REMOVE (E) PATIENT TABLE. 23 REMOVE (E) CONTROL CABINET. 24 REMOVE (E) STEP STOOL. 25 REMOVE (E) WALL MOUNTED APRON RACK. 26 REMOVE (E) WALL MOUNTED SIGN AND SAVE FOR REUSE. 27 REMOVE (E) STAND. 28 REMOVE (E) EXAM STOOL. 29 REMOVE (E) CEILING MOUNTED PATIENT SCANNER. 30 DEMO (E) CEILING AND COMPONENTS. 31 REMOVE & REPLACE CEILING TILES & GRID IN CORRIDOR 1502 AS NECESSARY TO COMPLETE DEMO WORK SHOWN ON SHEET M0-12 32 DEMO (E) GYP BD TO PREP WALL FOR INSTALL OF NEW LEAD SHIELDING. 33 EXTENTS OF CEILING DEMO. 34 DEMO GYP. BOARD SOFFIT. 35 DEMO T-BAR GRID AND TILES AS SHOWN. 36 DEMO EXISTING SIGNAGE. PROTECT EXISTING SUBSTRATE TO REMAIN IN PLACE. 37 DEMO EXISTING CARD READER. 38 DEMO (E) WALL MOUNTED XCEL X-RAY MACHINE 39 CAREFULLY REMOVE & STORE WOOD TRIM & BASE FOR REUSE. SEE INTERIOR ELEVATIONS FOR REINSTALLATION LOCATION. 40 (E) CARD READER TO REMAIN 41 DEMO (E) ELECTRICAL PANEL. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 42 DEMO (E) SURGE PROTECTION DEVICE. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 43 REMOVE (E) CARD READER & SALVAGE. SEE SHEET A1-13 & SECURITY SHEETS FOR REMODEL WORK. 44 DEMO (E) DUKANE DEVICE 45 REMOVE (E) WALL DUCT 46 DEMO (E) STRUCTURAL STEEL ABOVE CEILING AND INSIDE WALLS 47 DEMO (E) LEAD-LINED GYP BOARD ABOVE CEILING 48 DEMO (E) LEAD-LINED GYP BOARD ON WALLS. PROTECT FRAMING TO REMAIN IN PLACE 49 REMOVE & STORE (E) FIRE EXTINGUISHER. SEE REMODEL PLAN FOR REINSTALLATION LOCATION KEY PLAN CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 2.7 2.5 2.3 1.4 F G H J K 1 1' - 8 " 11" 4' - 0 " 1' - 9 " 1' - 6 " 10 ' - 1 1 / 2 " 8' - 2 1/4" 3' - 0"3" 4' - 0" 4' - 0 " 3' - 9 1 / 2 " 2 2 3 1518 TOILET/LAV, GENERAL TLGEN 1517 TOILET/LAV, GENERAL TLGEN 1515 DRESSING ROOM DRESSB 1516 DRESSING ROOM DRSSB 1513 ACCESSIBLE DRESSING BOOTH DRSSA 1510 SUBWAIT ROOM 1502 CORRIDOR CORRD 1509 STORAGE, GENERAL SGENL 1529 ENVIRONMENTAL SERVICES CLOSET EVSRM 1507A ACCESSIBLE DRESSING BOOTH DRSSA 1507 IMAGING, MAMMOGRAPHY IMAMO 1508 HALLWAY HALLW 1617 OFFICE, PROVIDER OPROV 1602 HALLWAY HALLW IMAGINE GENERAL IGENL 1505 WORK AREA, TECHNICIAN WATEC 1506 DRESSING BOOTH DRSSB 1512 DRESSING BOOTH DRSSB 1514 HALLWAY HALLW 1504 VESTIBULE VESTI 1504A VESTIBULE VESTI 1511 7' - 2" 5' - 0" 2' - 6 " N NOT APPLICABLE GENERAL NOTES DEMOLITION OF NON-RATED PARTITION AREA OF WORK (E) NON-RATED PARTITION R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:24:29 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A0-14 PLAN - DEMO CONCRETE 1ST FLR CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 1/4" = 1'-0"PLAN - DEMO CONCRETE 1ST FLR 01 R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO: FLOOR LEV: SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 5 0 ' GR A P H I C S C A L E S : 1 / 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:24:29 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A0-14 PLAN - DEMO CONCRETE 1ST FLR CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 GENERAL NOTES SHEET KEYNOTES N KEY PLAN LEGEND 1 SAWCUT (E) SLAB FOR NEW CONDUIT TRENCH. SEE 24/S5-01 FOR ADDITIONAL INFORMATION. 2 SAWCUT (E) SLAB. SEE 11/S5-01 FOR TABLE & 21/S5-01 FOR WALL STAND. 3 SAWCUT (E) SLAB FOR CONNECTION OF (N) LAVATORY WASTE TO (E) 2" WASTE. SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 E A S T F O U R T H S T R E E T CR CR RE X T AREA OF WORK (E) PARTITION DEPARTMENT BOUNDRY (N) PARTITION LEGEND NOT APPLICABLE NOT APPLICABLE 10 9 8 7 6 5 4 1 3 L M N P Q A B C D E F G H J K 2 1108 TRASH1105 SLINC 1014 OPROV 1013 WSGEN 1012 EXROM1011 OPROV 1104 HALLW1015 EXROM1017 WSGEN 1310W01 WSGEN 1018 WSGEN 1010 EXROM 1009 EXROM 1150 HALLW 1109 EQRTR1107A SGENL 1103 SEQGN 1102 WRGEN 1016 EXROM1019 EXROM 1008 EXROM 1154A SCLOS 1101 CORRD1020 TLSTF 1007 EXROM 1153A VESTI 1153 SGENL 1154 TLPUB 1155 TLPUB 1150B ADRFT 1021 TLPAT1033 EQELC 1030 HALLW 1211 CONFR 1213 UTILC 1214 EXROM 1224 TLSTF 1215 AMENR 1024 UTILC 1022 PRMIN 1023 UTILS1006 OPROV 1005 EXROM 1209 HALLW 1025 AMENR 1029 HALLW1004 EXROM 1203 OPROV1217 WACPF 1216 OGENL 1223 EXROM 1026 AAMEN1003 WACPF 1204 OPROV 1217W01 WSGEN 1217W02 WSGEN 1217W03 WSGEN 1217W04 WSGEN 1217W05 WSGEN 1217W06 WSGEN 1210 HALLW 1027 WSGEN1002 OGENL 1028 WSGEN 1200 WTAGN1222 EXROM1221 EXROM 1220 EXROM 1218 UTILS 1300 CORRD 1001 WTAGN 1219 MEDPR 1201 RECEP 1212 HALLW 1206 EXROM1207 EXROM 1208 EXROM 1202 SGENL 1312 WAGEN 1312W01 WSGEN 1301 WTAGN1302 RECEP 1311B WACPF 1311A WACPF 1311 HALLW 1316 WTAGN1310 RECEP 1315 OGENL 1314 OGENL 1313 OGENL 102 WSGEN 1406 SMEDS 1408 OGENL 1407 OGENL 1409 EQMEC 1410 EQELV 1405 SGENL 1500 COORD 1404 TLSTF1403 WADIS 1401 WTAGN 1402 CONSR 1205 OPROV 1031 HALLW 1411 EQMEC 1498 ATELE 1499 OGENL 1501 LOBBY EL01 ELEVA 1528 SEQGN 1529 EVSRM 1527 OGENL 1535 SSUPP 1509 SGENL 1507 IMAMO 1513 DRSSA 1502 CORRD 1514 WSGEN1517 TLGEN 1518 TLGEN 1505 SHELL 1504A VESTI 1617 OPROV 1616 EXROM 1620 WSGEN 1621 WSGEN 1622 TLPUB 1623 WSGEN 1624 AGENL 1625 EXROM 1630 EXROM 1626 EXROM 1627 EXROM 1628 OGENL 1629 TLGEN 1615 EXROM 1614 EXROM 1613 OPROV1612 EXROM 1611 EXROM1610 OPROV 1609 OPROV 1608 UTILC 1608A WSGEN 1602 HALLW 1605 EXROM 1606 EXROM 1607 EXROM 1808 TLPUB 1809 CORRD 1810 SGENL 1807 SGENL 1805 CONFR 1800A CORRD 1800 CORRD 1804 LNGST 1802 KITCH 1801 EVSRM 1800C VESTI 1706 EXROM 1707 EXROM 1708 UTILS 1704 HALLW 1704A UTILG 1726 OPROV 1711 EXROM 1709 PRMIN 1601 HALLW 1600 HALLW 1710 OGENL 1712 EXROM 1713 WSGEN 1714 WSGEN 1715 WRGEN 1716 TLPUB 1717 WSGEN 1718 WSGEN 1725 EXROM 1724 OPROV 1723 EXROM 1722 OPROV 1721 EXROM 1720 OPROV 1719 EXROM 1531 LNGST 1530 WAGEN 1532 OBSRM 1536 VESTI 1538 TLPTS 1534 LBTRY 1537 TLPTS 1534B BLDDR 1534C BLDDR 1534D BLDDR 1701 WTAGN 1702 RECEP 1703 WTAGN 1604 WTAGN 1800B VESTI 1803 TLPUB 1705 HALLW 1507A DRSSA 1506 IGENL 1511 DRSSB PEDIATRICS OBSTETRICS / GYNECOLOGY PEDIATRICS RADIOLOGY - GENERAL BLOOD DRAW LAB PRIMARY CARE MEMBER SERVICE CENTERENVIRONMENTAL SERVICESOBSTETRICS / GYNECOLOGY N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:21:57 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A1-11 PLAN - REMODEL OVERALL 1ST FLR CA361 1 1 - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 GENERAL NOTES SHEET KEYNOTES N 1/16" = 1'-0"PLAN - REMODEL OVERALL 1ST FLOOR 01 KEY PLAN CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 C RE X T-BAR CEILING GYP. BD. CEILING AREA OF WORK (E) PARTITION DEPARTMENT BOUNDRY (N) PARTITION 10 9 8 7 6 5 4 1 3 L M N P QABCDEFGHJK 2 CONFERENCE ROOMS PEDIATRICS OBSTETRICS / GYNECOLOGY PEDIATRICS RADIOLOGY - GENERAL BLOOD DRAW LAB MHW MENTAL HEALTH/ PSYCHIATRY MEDICAL OFFICE ADMINISTRATION O/P PHARMACY PRIMARY CARE FAMILY MEDICINE MEMBER SERVICE CENTER MEDICAL OFFICE ADMINISTRATION MEDICAL OFFICE ADMINISTRATION MATERIAL MGMT-ADMIN ENVIRONMENTAL SERVICES ENVIRONMENTAL SERVICES ENVIRONMENTAL SERVICES OBSTETRICS / GYNECOLOGY 03 A1-13 1108 TRASH1105 SLINC 1014 OPROV 1013 WSGEN 1012 EXROM1011 OPROV 1104 HALLW1015 EXROM1017 WSGEN 1310W01 WSGEN 1018 WSGEN 1010 EXROM 1009 EXROM 1150 HALLW 1109 EQRTR1107A SGENL 1103 SEQGN 1102 WRGEN 1016 EXROM1019 EXROM 1008 EXROM 1154A SCLOS1101 CORRD1020 TLSTF 1007 EXROM 1153A VESTI 1153 SGENL 1154 TLPUB 1155 TLPUB 1150B ADRFT 1021 TLPAT1033 EQELC 1030 HALLW 1211 CONFR 1213 UTILC 1214 EXROM 1224 TLSTF 1215 AMENR 1024 UTILC 1022 PRMIN 1023 UTILS1006 OPROV 1005 EXROM 1209 HALLW 1025 AMENR 1029 HALLW1004 EXROM 1203 OPROV1217 WACPF 1216 OGENL 1223 EXROM 1026 AAMEN1003 WACPF 1204 OPROV 1217W01 WSGEN1217W02 WSGEN 1217W03 WSGEN 1217W04 WSGEN 1217W05 WSGEN 1217W06 WSGEN 1210 HALLW 1027 WSGEN1002 OGENL 1028 WSGEN 1200 WTAGN1222 EXROM1221 EXROM 1220 EXROM 1218 UTILS 1300 CORRD 1001 WTAGN 1219 MEDPR 1201 RECEP 1212 HALLW 1206 EXROM1207 EXROM 1208 EXROM 1202 SGENL 1312 WAGEN 1312W01 WSGEN 1301 WTAGN1302 RECEP 1311B WACPF 1311A WACPF 1311 HALLW 1316 WTAGN 1310 RECEP 1315 OGENL 1314 OGENL 1313 OGENL 102 WSGEN 1406 SMEDS 1408 OGENL 1407 OGENL 1409 EQMEC1410 EQELV 1405 SGENL 1500 COORD 1404 TLSTF1403 WADIS 1401 WTAGN 1402 CONSR 1205 OPROV 1031 HALLW 1411 EQMEC 1498 ATELE 1499 OGENL 1501 LOBBY EL01 ELEVA 1528 SEQGN 1529 EVSRM 1527 OGENL 1535 SSUPP 1509 SGENL 1507 IMAMO 1506 IGENL 1513 DRSSA 1502 CORRD1514 WSGEN 1517 TLGEN 1518 TLGEN 1505 SHELL 1504A VESTI 1617 OPROV 1616 EXROM 1620 WSGEN 1621 WSGEN1622 TLPUB 1623 WSGEN 1624 AGENL 1625 EXROM 1630 EXROM 1626 EXROM 1627 EXROM 1628 OGENL 1629 TLGEN 1615 EXROM 1614 EXROM 1613 OPROV 1612 EXROM1611 EXROM1610 OPROV 1609 OPROV 1608 UTILC 1608A WSGEN 1602 HALLW 1605 EXROM 1606 EXROM 1607 EXROM 1808 TLPUB 1809 CORRD 1810 SGENL 1807 SGENL 1805 CONFR 1800A CORRD 1800 CORRD 1804 LNGST 1802 KITCH 1801 EVSRM 1800C VESTI 1706 EXROM 1707 EXROM 1708 UTILS 1704 HALLW 1704A UTILG 1726 OPROV 1711 EXROM 1709 PRMIN 1601 HALLW 1600 HALLW 1710 OGENL 1712 EXROM 1713 WSGEN 1714 WSGEN 1715 WRGEN 1716 TLPUB 1717 WSGEN 1718 WSGEN 1725 EXROM 1724 OPROV 1723 EXROM 1722 OPROV 1721 EXROM 1720 OPROV 1719 EXROM 1531 LNGST 1530 WAGEN 1532 OBSRM 1536 VESTI 1538 TLPTS 1534 LBTRY 1533 BLDDR 1537 TLPTS 1534B BLDDR 1534C BLDDR 1534D BLDDR 1701 WTAGN 1702 RECEP 1703 WTAGN 1604 WTAGN 1800B VESTI 1803 TLPUB 1705 HALLW 1507A DRSSA NOT APPLICABLE NOT APPLICABLE N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:22:04 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A1-12 PLAN - REMODEL OVERALL RCP 1ST FLR CA361 1 1 - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 GENERAL NOTES SHEET KEYNOTES LEGEND 1/16" = 1'-0"PLAN - REMODEL OVERALL RCP 1ST FLR 01 N KEY PLAN CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 J 1 D D PS EPO ESES PS PS D D CR CR EP O RE X PS T C RE X OS OS OS OS OS OS C J 2 J 1 D 2.7 2.5 2.3 1.4 F G H J K 1501 LOBBY LOBBY 1529 ENVIRONMENTAL SERVICES CLOSET EVSRM 1509 STORAGE, GENERAL SGENL 1507 IMAGING, MAMMOGRAPHY IMAMO 1506 IMAGING, GEN IGENL 1513 ACCESSIBLE DRESSING BOOTH DRSSA 1502 CORRIDOR CORRD 1517 TOILET/LAV, GENERAL TLGEN 1518 TOILET/LAV, GENERAL TLGEN 1505 SHELL SPACE SHELL 1617 OFFICE, PROVIDER OPROV 1602 HALLWAY HALLW 1701 WAITING AREA, GENERAL WTAGN 1507A ACCESSIBLE DRESSING BOOTH DRSSA 30"X36" CLR 1 2 3 4 1506A CONTROL ROOM CRRAD 1514 TECH WORKSTATION WSGEN 1504B HALLWAY HALLW 15 0 5 1504 15 0 6 15 1 1 65 74 1511 DRESSING BOOTH DRSSB 8 8 15 1 3 1504A HALLWAY HALLW 10 10 10 11 12 4 1510 SUBWAIT ROOM 1508 HALLWAY HALLW 13 1 15 17 1. U.N.O., ALL ITEMS ARE CONTRACTOR FURNISHED, CONTRACTOR INSTALLED (C.F.C.I.). 2. FOR MEDICAL EQUIPMENT & FURNITURE INFORMATION, SEE 3. FOR INTERIOR FINISH INFORMATION, SEE 4. U.N.O., ALL CEILING MOUNTED EQUIPMENT AND DEVICES ARE EXISTING AND SHOWN FOR REFERENCE ONLY. 5. U.N.O., ALL ITEMS ARE CONTRACTOR FURNISHED, CONTRACTOR INSTALLED (C.F.C.I.). 6. U.N.O., CENTER ACOUSTICAL CEILING TILES WITHIN ROOM. 7. U.N.O., CEILING MOUNTED DEVICES ARE CENTERED IN CEILING TILE. 8. U.N.O., ALL CEILING TILE, T-BAR, HVAC DIFFUSERS/ REGISTERS, AND LIGHT FIXTURES ARE NEW IN ROOMS 1504, 1504A, 1505, 1506, 1513, 1514, 1515, 1516. 9. U.N.O., (N) NURSE CALL LIGHTS SHOULD BE CENTERED ABOVE THE DOOR OPENING. 01 /Q1-11 01/I1-11 2.7 2.5 2.3 1.4 F G H J K 2 1529 ENVIRONMENTAL SERVICES CLOSET 1509 STORAGE, GENERAL 1507 IMAGING, MAMMOGRAPHY 1506 IMAGING, GEN 1513 ACCESSIBLE DRESSING BOOTH 1502 CORRIDOR 1517 TOILET/LAV, GENERAL1518 TOILET/LAV, GENERAL 1505 SHELL SPACE 1617 OFFICE, PROVIDER 1602 HALLWAY 1701 WAITING AREA, GENERAL 1507A ACCESSIBLE DRESSING BOOTH (E) +9' - 0"AFF (E) +9' - 0"AFF (E) +9' - 0"AFF (E) +9' - 0"AFF NOTE: PER IMAGING EQUIPMENT VENDOR DRAWINGS, "IN THIS RECTANGULAR SHADED AREA, NOTHING CAN EXTEND BELOW THE FINISHED CEILING TO ALLOW FREE MOVEMENT OF THE CEILING X-RAY TUBE STAND." 1514 TECH WORKSTATION WSGEN 1504B HALLWAY HALLW 1511 DRESSING BOOTH DRSSB 9 +9' - 0"AFF +9' - 0"AFF (E) +9' - 0"AFF +9' - 0"AFF 4' - 7 1 / 2 " 3' - 9 " 1508 HALLWAY 1510 SUBWAIT ROOM 1504A HALLWAY 16' - 0" 14 +9' - 0"AFF 11 15/16" 2' - 0 " 16 18 +9' - 0"AFF 1' - 8"1' - 8"2' - 2"2' - 2"2' - 2"2' - 2"2' - 2"1' - 0"3 1/4" 3' - 0 " 1' - 0 " 1' - 0 " 4' - 0 " 3' - 0 " 1' - 0 " 1' - 0 " RAUN 216-9 RAUN 216-10 2 5 / 8 " 6' - 4"5' - 4" +1'-0"AFF CEILING HEIGHT TAG DIFFUSERS / REGISTERS RECESSED LIGHT FIXTURE RECESSED SPEAKER SPRINKLER (DEFERRED APPROVAL) RECESSED ELECTRICAL JUNCTION BOX SMOKE DETECTOR (DEFERRED APPROVAL) WALL MOUNTED NURSE CALL LIGHT FIRE ALARM DEVICE (DEFERRED APPROVAL) (N) NON-RATED PARTITION AREA OF WORK (E) NON-RATED PARTITION (E) 1-HR RATED FIRE BARRIER FOR SHAFTS PER CBC 407.4.4 GROUP I-2 AND I-2.1 CARE SUITES, 707 FIRE BARRIERS, 707.3.9 SEPERATED OCCUPANCIES 45 MIN OPENINGS PER TABLE 716.5 CEILING ACCESS PANEL EXIT SIGN DATA OUTLET (MODTAP) -SINGLE GANG BOX DATA OUTLET (MODTAP) -DOUBLE GANG BOX DATA -CEILING MOUNTED WIRELESS ACCESS POINT FLUSH MOUNTED ENCLOSURE JUNCTION BOXES (NUMBER DESIGNATES GANG SIZE) SWITCH -DIMMER -SINGLE GANG BOX SURFACE MOUNTED ENCLOSURE ELECTRICAL RECEPTICAL, SINGLE ELECTRICAL RECEPTICAL, DUPLEX ELECTRICAL RECEPTICAL, QUADRAPLEX NEW LEAD-LINED GYP CEILING N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO:BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jguevara\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jguevaraY9UQJ.rvt 5/20/2024 1:57:52 PM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A1-13 PLAN - REMODEL 1ST FLR CA361 1 1 - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 GENERAL NOTES SHEET KEYNOTES LEGEND 1/4" = 1'-0"PLAN - REMODEL 1ST FLR 01 N 1 INSTALL (N) PATIENT TABLE. 2 INSTALL (N) WALL STAND WITHN FIXED DETECTOR. 3 INSTALL (N) FLOOR DUCT. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 4 INFILL FRAMING PER DETAIL 13/A5-02. 5 INSTALL (N) LAVATORY. SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 6 INSTALL (N) BASE & UPPER CABINETS. 7 INSTALL (N) GENERATOR CABINET. 8 INSTALL (N) DRESSING ROOM BENCH. 9 INSTALL (N) GYP BOARD SOFFIT. SEE 17/A5-04 FOR ADDITIONAL INFORMATION. 10 EXTENTS OF (N) FLOORING. 11 INSTALL (N) LEAD-LINED WINDOW. REFER TO PHYSICIST REPORT ON SHEET Q8-11 FOR ADDITIONAL INFORMATION 12 INSTALL (N) DISCONNECT SWITCH. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION 13 INSTALL (E) CARD READER. SEE SECURITY SHEETS FOR ADDITIONAL INFORMATION. 14 INSTALL (N) CEILING MOUNTED PULL BOX. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 15 INSTALL (E) FIRE EXTINGUISHER IN (N) SEMI-RECESSED FIRE EXTINGUISHER CABINET 16 REMOVE & REPLACE CEILING TILES & GRID HALLWAY 1602 AS NECESSARY TO COMPLETE REMODEL WORK SHOWN ON SHEET M1-12 17 INSTALL (E) THERMOSTAT AT THIS LOCATION. SEE SHEET M1-12 FOR ADDITIONAL INFORMATION 18 INSTALL (N) CEILING ACCESS PANEL TO ACCESS THE VOLUME DAMPERS. SEE SHEET M1-12 FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"PLAN - REMODEL RCP 1ST FLR 03 N KEY PLAN CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 J 1 D D PS EPO ESES PS PS D D CR CR EP O PS T 2.7 2.5 2.3 1.4 F G H J K 05/ A2-01 04 / A 2 -01 03/ A2-01 02/ A2-01 12 / A 2 -01 13 / A 2 -01 14/ A2-01 20 / A 2 -01 15/ A2-01 01/ A2-02 02 / A 2 -02 03/ A2-02 13/ A2-02 04 / A 2 -02 02/ A2-03 05 / A 2 -03 04/ A2-03 07/ A2-03 08 / A 2 -03 09/ A2-03 12 / A 2 -02 07/ A2-02 09/ A2-02 06 / A 2 -02 11/ A2-02 06 / A 2 -0301/ A2-03 11/ A2-03 08 / A 2 -02 03 / A 2 -0310 / A 2 -03 1501 LOBBY LOBBY 1529 ENVIRONMENTAL SERVICES CLOSET EVSRM 1509 STORAGE, GENERAL SGENL 1507 IMAGING, MAMMOGRAPHY IMAMO 1506 IMAGING, GEN IGENL 1513 ACCESSIBLE DRESSING BOOTH DRSSA 1502 CORRIDOR CORRD 1517 TOILET/LAV, GENERAL TLGEN1518 TOILET/LAV, GENERAL TLGEN 1505 SHELL SPACE SHELL 1617 OFFICE, PROVIDER OPROV 1602 HALLWAY HALLW 1701 WAITING AREA, GENERAL WTAGN 1507A ACCESSIBLE DRESSING BOOTH DRSSA 30"X36" CLR 1506A CONTROL ROOM CRRAD 1514 TECH WORKSTATION WSGEN 1504B HALLWAY HALLW 15 0 5 1504 15 0 6 15 1 1 1511 DRESSING BOOTH DRSSB 15 1 3 1504A HALLWAY HALLW B3 - B3 - B3 - B4 - B3 - B3 - B3 - B3 - B3 - B3 - B3 - B3 - 3' - 9 " 3' - 1 1 " 14 / A 2 -02 05 / A 2 -02 1508 HALLWAY HALLW 1510 SUBWAIT ROOM 10/ A2-02 AL I G N ALIGN AL I G N AL I G N AL I G N AL I G N 4' - 5"7' - 5" 6' - 5 7 / 8 " 2' - 7 1 / 2 " 6 5/8" 4' - 3 1 / 4 " 5' - 8 5 / 8 " 7' - 4 3/8" 16 ' - 0 " C6 - B6 - 1 2 TYP TYP 12 / A 2 -03 135° C2 - 4" 5' - 0 " 3' - 0" 1' - 8 1 / 2 " 1' - 1 1 1 / 2 " N DEMOLITION OF NON-RATED PARTITION AREA OF WORK (E) NON-RATED PARTITION R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 7/3/2024 8:09:28 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A1-14 PLAN - REMODEL ENLARGED - DIMENSION & PARTITION TYPE CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 1/4" = 1'-0"PLAN - REMODEL ENLARGED - 1ST FLR 01 GENERAL NOTES SHEET KEYNOTES LEGEND KEY PLAN NOT APPLICABLE 1 (N) HSS INSIDE PARTIAL HEIGHT WALL. SEE 19/S5-01 FOR ADDITIONAL INFORMATION. 2 (N) HSS INSIDE FULL HEIGHT WALL. SEE 13/S5-01 FOR ADDITIONAL INFORMATION. CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 PLAN CHECK CORRECTIONS 07/02/2024 1900 E 4th St - 1011190678/9/2024 (N) DATA PORT (N) ELECTRICAL RECEPTACLE. 1001A DOOR TAG - SEE DOOR SCHEDULE ON SHEET A6-01 W 2400 L LOCK CASEWORK TAG KAISER VERNON MODEL NUMBER - LETTER DESIGNATOR FOR HINGE LOCATION, WHERE OCCURS COMMENT ( "M" INDICATES MODIFICATION TO STANDARDIZED MODEL.) (N) DIMMABLE LIGHT SWITCH. CHTK 800E-AA FURNITURE TAG - SEE FURNITURE SCHEDULE ON SHEET Q1-11 MODO 800E EQUIPMENT TAG - SEE EQUIPMENT SCHEDULE ON SHEET Q1-11 SPEC SPEC NO ( A SUFFIX OF "E" INDICATES EXISTING FURNITURE) SPEC SPEC NO ( A SUFFIX OF "E" INDICATES EXISTING EQUIPMENT) ACCESSORIES TAG - SEE ACCESSORIES SCHEDULE ON SHEET Q1-11 SPEC ( A SUFFIX OF "E" INDICATES EXISTING ACCESSORIES) MODO 800E (N) EMERGENCY SHUT OFF BUTTON. (N) NURSE PULL CORD SURFACE MOUNTED WIREWAY (N) THERMOSTAT 2' - 1 0 " 1' - 8 " 2' - 6 " 1' - 7"1' - 3"10"5' - 8" 2' - 0" MW 3600 MB 3620 1506 PTD DG SD 4' - 7" 1 9 8 4' - 0 " 1' - 0 " OPEN COSH 518 DIGL 211 MW 3600 MB 3620 1' - 5" 1' - 3" 1 7' - 0 " 9 3/4" OPEN TO CONTROL RM 9" 1 2 3 4' - 0 " 7' - 0 " 3' - 1" 1 STDO 274 STIV 216 TRCY 215 SHRA 204 1 COWA 202 PUIN 242 RAUN 216-7 RAUN 216-6 6' - 7" RAUN 216-9 RAUN 216-10 RAUN 216-8 STST 216 RAUN 216-6 RAUN 216-7 1 4 RAUN 216-11 4' - 0" 2' - 3 " 6 1' - 11"3' - 10"11" BOTR 203 5' - 1 " 6' - 1 " 6 CHSM 803 SHRA 204 1 MOPE 800 PRIN 200 1' - 8"6" 6 3' - 1 0 " 3' - 0 " BOBU 805 6RAAL 224 6' - 4"2' - 0"1' - 0"6"6"3' - 2" 6 APLE 203 4' - 2 " 5' - 0 " 1 PRIN 200 MOPE 800 5 1' - 6" OPEN TEPH 200 TAAM 802 1' - 3 " 6" 1 7 COTE 200 EGRK 801 1' - 8"6" OPEN TO X-RAY ROOM RAUN 216-3 RAUN 216-4 TAAM 802 7' - 0 " M A X RAUN 216-13 RAUN 216-1 1' - 3 " 6" 2' - 6"6" 1 2 3 BACS 200 7 1 SCAN 200 COMPLY W/ SIDE REACH AT OBSTR. 46" MAX. TO TOP OF BOX HIGH ELECTRICAL RECEPTACLES / MODTAP (VOICE/DATA) OUTLETS, LIGHTING CONTROLS LOW ELECTRICAL RECEPTACLES / MODTAP (VOICE/DATA) OUTLETS TO BOT. OF BOX 15" MIN. COUNTER WHERE OCCURS 34" MAX. WALL HUNG SINK W/ PIPE WRAP PAPER TOWEL DISPENSER SOAP DISPENSER / DEGERMER COSH SHARPS CONTAINER 46" MAX. TO TOP OF BOX HIGH RECEPTACLES, VOICE/DATA OUTLETS & LIGHTING CONTROLS/ CARD READER ELECTRICAL PANEL MAX. 46" THERMOSTAT 56" MAX FULL LENGTH MIRROR STANDARD BACKING. SEE DETAIL 10/A5-02 MAX. 1' - 8" 40" MAX 72" NOTE: INSTALL OUTLET AS CLOSE TO SINK AS POSSIBLE TO HIDE FROM VIEW 1. U.N.O., POWER OUTLETS, J-BOXES, MOD-TAPS, SECURITY DEVICES, FIRE ALARM DEVICES AND LIGHTING CONTROLS ARE NEW. 2. U.N.O., DIMENSION SHOWN ARE FOR NEW POWER OUTLETS, J-BOXES, MOD-TAPS, LIGHTING CONTROLS AND SECURITY DEVICES. HORIZONTAL DIMENSIONS ARE SHOWN FOR REFERENCE AND CONTRACTOR TO COORDINATE FINAL LOCATIONS IN THE FIELD. 3. U.N.O., DIMENSIONS ARE TO CENTER OF DEVICES. N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:53:13 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A2-01 ELEVATIONS - INTERIOR CA361 1 1 - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 GENERAL NOTES SHEET KEYNOTES 011/2" = 1'-0"TYPICAL MOUNTING HEIGHTS 1/2" = 1'-0"1506 - IGENL - SOUTH ELEVATION 05 1/2" = 1'-0"1506 - IGENL - EAST ELEVATION 04 1/2" = 1'-0"1506 - IGENL - SOUTHEAST ELEVATION 03 1/2" = 1'-0"1506 - IGENL - NORTH ELEVATION 021/2" = 1'-0"1506 - IGENL - WEST ELEVATION 12 1/2" = 1'-0"1506 - IGENL - EAST ELEVATION 2 13 1/2" = 1'-0"1506A - CRRAD - SOUTH ELEVATION 14 1/2" = 1'-0"1506A - CRRAD - WEST ELEVATION 20 1/2" = 1'-0"1506A - CRRAD - EAST ELEVATION 15 LEGEND NOT USED NOT USED NOT USED NOT USED 1 NEW RUBBER TOPSET BASE. SEE FINISH LIST ON I1-11 FOR ADDITIONAL INFORMATION. 2 NEW CORNER GUARD.SEE FINISH LIST ON I1-11 FOR ADDITIONAL INFORMATION. 3 NEW LEAD-LINED WINDOW. SEE A6-01 FOR ADDITIONAL INFORMATION. 4 NEW 24"W X 60"H X 10"D PULL BOX. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 5 NEW DISCONNECT SWITCH. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION 6 NEW BACKING PER 10/A5-02. 7 NEW SURFACE-MOUNTED HORIZONTAL DUCT. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 8 NEW COAT HOOKS 9 NEW CLEAN OUT COVER. SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. KEY PLAN CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 1. U.N.O., POWER OUTLETS, J-BOXES, MOD-TAPS, SECURITY DEVICES, FIRE ALARM DEVICES, AND LIGHTING CONTROLS ARE EXISTING. 2. U.N.O., PROVIDE BACKING FOR WALL MOUNTED/ WALL ANCHORED EQUIPMENT. 3. U.N.O., DIMENSIONS SHOWN ARE FOR NEW POWER OUTLETS, J-BOXES, MOD-TAPS, LIGHTING CONTROLS, THERMOSTAT/ HUMIDSTAT, AND SECURITY DEVICES. HORIZONTAL DIMENSIONS ARE SHOWN FOR THESE DEVICES ARE FOR REFERENCE AND FINAL LOCATIONS ARE TO BE COORDINATED IN THE FIELD BY THE CONTRACTOR. 4. U.N.O., MOUNTING HEIGHTS ARE FOR POWER AND MOD-TAP DEVICES AS PER 5. U.N.O., DIMENSIONS ARE TO CENTER OF DEVICES. 22/G0-01 (N) DATA PORT (N) ELECTRICAL RECEPTACLE. 1001A DOOR TAG - SEE DOOR SCHEDULE ON SHEET A6-01 W 2400 L LOCK CASEWORK TAG KAISER VERNON MODEL NUMBER - LETTER DESIGNATOR FOR HINGE LOCATION, WHERE OCCURS COMMENT ( "M" INDICATES MODIFICATION TO STANDARDIZED MODEL.) (N) DIMMABLE LIGHT SWITCH. CHTK 800E-AA FURNITURE TAG - SEE FURNITURE SCHEDULE ON SHEET Q1-11 MODO 800E EQUIPMENT TAG - SEE EQUIPMENT SCHEDULE ON SHEET Q1-11 SPEC SPEC NO ( A SUFFIX OF "E" INDICATES EXISTING FURNITURE) SPEC SPEC NO ( A SUFFIX OF "E" INDICATES EXISTING EQUIPMENT) ACCESSORIES TAG - SEE ACCESSORIES SCHEDULE ON SHEET Q1-11 SPEC ( A SUFFIX OF "E" INDICATES EXISTING ACCESSORIES) MODO 800E (N) EMERGENCY SHUT OFF BUTTON. (N) NURSE PULL CORD SURFACE MOUNTED WIREWAY (N) THERMOSTAT 1 1506 2 3 2 3 11' - 4" 1 OPEN 3 9" 1 3 1 2 4' - 0 " OPEN 1 55 EQ EQ EQ EQ 2 4' - 0 " 1513 1511 OPEN OPEN 2 3 3 1 1504 3 3 4 3' - 1"4' - 8"6" SFDP 801 CHSM 803 COTE 200 EGRK 801 TAAM 800 CHTK 802 EQ EQ 2" 1 OPEN 2 1 3 2' - 8" OPEN SFDP 801 SFDP 801 SFDP 802 1 OPEN 2 1 N 7 6 1 2 OPEN OPEN COTE 200 BACS 200 SCAN 200 TEPH 200 TAAM 800 SFDP 801 SFDP 801 SFDP 802 EGRK 801 R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:23:37 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A2-02 ELEVATIONS - INTERIOR CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 GENERAL NOTES SHEET KEYNOTES LEGEND 1/2" = 1'-0"1504B - HALLW - NORTH ELEVATION 01 1/2" = 1'-0"1504B - HALLW - EAST ELEVATION 04 1/2" = 1'-0"1504B - HALLW - SOUTH ELEVATION 13 1/2" = 1'-0"1504B - HALLW - WEST ELEVATION 08 1/2" = 1'-0"1504B - HALLW - SOUTH ELEVATION 2 03 1/2" = 1'-0"1504B - HALLW - WEST ELEVATION 2 021/2" = 1'-0"1514 - WORK STATION - EAST ELEVATION 12 1/2" = 1'-0"1514 - WORK STATION - SOUTH ELEVATION 07 1/2" = 1'-0"1504B - HALLW - SOUTH ELEVATION 3 09 1/2" = 1'-0"1504B - HALLW - EAST ELEVATION 2 061/2" = 1'-0"1504B - HALLW - NORTH ELEVATION 2 11 KEY PLAN 1/2" = 1'-0"1602 HALLW - EAST ELEVATION 14 1/2" = 1'-0"1508 - HALLW - WEST ELEVATION 3 051/2" = 1'-0"1514 - WSGEN - NORTH ELEVATION 10 1 NEW RUBBER TOPSET BASE. SEE FINISH LIST ON I1-11 FOR ADDITIONAL INFORMATION. 2 NEW CORNER GUARD.SEE FINISH LIST ON I1-11 FOR ADDITIONAL INFORMATION. 3 NEW SIGN. SEE SIGNAGE PACKAGE FOR ADDITIONAL INFORMATION. 4 NEW REQUEST TO EXIT. SEE SECURITY DWGS FOR ADDITIONAL INFORMATION. 5 NEW WALL-MOUNTED CORRIDOR LIGHT. 6 REINSTALL (E) SALVAGED BASE. 7 REINSTALL (E) SALVAGED WOOD TRIM. ALIGN WITH (E) WOOD TRIM ON ADJACENT WALLS. CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 1. U.N.O., POWER OUTLETS, J-BOXES, MOD-TAPS, SECURITY DEVICES, FIRE ALARM DEVICES, AND LIGHTING CONTROLS ARE EXISTING. 2. U.N.O., PROVIDE BACKING FOR WALL MOUNTED/ WALL ANCHORED EQUIPMENT. 3. U.N.O., DIMENSIONS SHOWN ARE FOR NEW POWER OUTLETS, J-BOXES, MOD-TAPS, LIGHTING CONTROLS, THERMOSTAT/ HUMIDSTAT, AND SECURITY DEVICES. HORIZONTAL DIMENSIONS ARE SHOWN FOR THESE DEVICES ARE FOR REFERENCE AND FINAL LOCATIONS ARE TO BE COORDINATED IN THE FIELD BY THE CONTRACTOR. 4. U.N.O., MOUNTING HEIGHTS ARE FOR POWER AND MOD-TAP DEVICES AS PER 5. U.N.O., DIMENSIONS ARE TO CENTER OF DEVICES. 22/G0-01 (N) DATA PORT (N) ELECTRICAL RECEPTACLE. 1001A DOOR TAG - SEE DOOR SCHEDULE ON SHEET A6-01 W 2400 L LOCK CASEWORK TAG KAISER VERNON MODEL NUMBER - LETTER DESIGNATOR FOR HINGE LOCATION, WHERE OCCURS COMMENT ( "M" INDICATES MODIFICATION TO STANDARDIZED MODEL.) (N) DIMMABLE LIGHT SWITCH. CHTK 800E-AA FURNITURE TAG - SEE FURNITURE SCHEDULE ON SHEET Q1-11 MODO 800E EQUIPMENT TAG - SEE EQUIPMENT SCHEDULE ON SHEET Q1-11 SPEC SPEC NO ( A SUFFIX OF "E" INDICATES EXISTING FURNITURE) SPEC SPEC NO ( A SUFFIX OF "E" INDICATES EXISTING EQUIPMENT) ACCESSORIES TAG - SEE ACCESSORIES SCHEDULE ON SHEET Q1-11 SPEC ( A SUFFIX OF "E" INDICATES EXISTING ACCESSORIES) MODO 800E (N) EMERGENCY SHUT OFF BUTTON. (N) NURSE PULL CORD SURFACE MOUNTED WIREWAY (N) THERMOSTAT 1 1505 3 5' - 0" 7 1 1' - 5"1' - 5" 2 1513 1 3' - 6"1' - 7" 1 06 A5-03 5' - 0 " 3 4 4' - 0" 1 4 1' - 8" 1 1511 4"3' - 0" 1 4 06 A5-03 3 4 1 BEHIND BENCH 5' - 0 " EQEQ 2' - 3" 1 2 4 1 3 3 3 5" 7' - 0 " 1' - 3" 3' - 4 " 1 1504 EQ EQ 3 5 N 6 R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 7/3/2024 8:09:22 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A2-03 ELEVATIONS - INTERIOR CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 GENERAL NOTES SHEET KEYNOTES LEGEND 1/2" = 1'-0"1504A - HALLW - NORTH ELEVATION 01 1/2" = 1'-0"1513 - DRSSA - NORTH ELEVATION 02 1/2" = 1'-0"1513 - DRSSA - EAST ELEVATION 03 1/2" = 1'-0"1513 - DRSSA - SOUTH ELEVATION 04 1/2" = 1'-0"1513 - DRSSA - WEST ELEVATION 05 1/2" = 1'-0"1511 - DRSSB - NORTH ELEVATION 07 1/2" = 1'-0"1511 - DRSSB - EAST ELEVATION 08 1/2" = 1'-0"1511 - DRSSB - SOUTH ELEVATION 09 1/2" = 1'-0"1511 - DRSSB - WEST ELEVATION1 10 1/2" = 1'-0"1504A - HALLW - SOUTH ELEVATION 11 1/2" = 1'-0"1504A - HALLW - EAST ELEVATION 06 KEY PLAN 1/2" = 1'-0"1517 - TLGEN - EAST ELEVATION 12 1 NEW RUBBER TOPSET BASE. SEE FINISH LIST ON I1-11 FOR ADDITIONAL INFORMATION. 2 NEW FULL LENGTH MIRROR. SEE 01/A2-01 FOR ADDITIONAL INFORMATION. 3 NEW SIGN. SEE SIGNAGE PACKAGE FOR ADDITIONAL INFORMATION. 4 NEW DRESSING BENCH WITH DRAWER 5 NEW CARD READER. SEE SECURITY DRAWINGS FOR ADDITIONAL INFORMATION. 6 INSTALL (N) BLANK COVER PLATE AT REMOVED PULL STRING 7 PROVIDE MAKE READY J-BOX FOR FUTURE CARD READER CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 PLAN CHECK CORRECTIONS 07/02/2024 1900 E 4th St - 1011190678/9/2024 CONCRETE FLOORS: UL-CLASSIFIED TYPE OF PENETRANT SYSTEM F-RATING (HR)T-RATING (HR) CIRCULAR BLANK OPENING 2 3 1.5 3 C-AJ-0090 C-AJ-0086 SINGLE METAL PIPE OR CONDUIT 2 0C-AJ-1126 SINGLE OR BUNDLED CABLES 2 0C-AJ-3095 GYPSUM WALLBOARD ASSEMBLIES: UL-CLASSIFIED TYPE OF PENETRANT SYSTEM F-RATING (HR)L-RATING METAL PIPES OR CONDUIT 1 2 W-L-1054 W-L-1054 NON-METALLIC PIPE OR CONDUIT 1 2 W-L-2128 W-L-2128 SINGLE OR BUNDLED CABLES 1 2 W-L-3065 W-L-3065 CABLE TRAY 1 2 W-L-4011 W-L-4011 INSULATED PIPES 1 2 W-L-5028 W-L-5028 1 CFM / SF 1 CFM / SF 8 CFM / SF 8 CFM / SF 5 CFM / SF 5 CFM / SF 1 CFM / SF 1 CFM / SF CONTRACTOR TO PROVIDE FIRESTOPPING SUBMITTAL TO ARCHITECT OF RECORD FOR REVIEW AND APPROVAL. SUBMITTAL SHALL INCLUDE FIRESTOPPING DETAILS (WITH APPROVED UL REFERENCE) COORDINATED WITH A LOCATION FLOOR PLAN. SUBMITTAL TO INCLUDE ENGINEERING JUDGEMENT IF REQUIRED. SIMILAR FOR FIRE-PROOFING PROVISIONS IF NECESSARY. (IN OSHPD APPLICATIONS, THIS SUBMITTAL SHALL BE REVIEWED IN THE FIELD FOR CONCURRENCE BY THE FLSO) 1. CERTIFIED SINGLE-AND DOUBLE-GANG METALLIC OUTLET AND SWITCH BOXES WITH METALLIC OR NONMETALLIC COVER PLATES MAY BE USED IN NONBEARING STEEL STUD WALLS WITH RATINGS NOT EXCEEDING 2 HR. THE METALLIC OUTLET OR SWITCH BOXES SHOULD BE SECURELY FASTENED TO THE STUDS AND THE OPENING IN THE WALLBOARD FACING SHOULD BE CUT SO THAT THE CLEARANCE BETWEEN THE BOX AND THE WALLBOARD DOES NOT EXCEED 1/8 IN. THE SURFACE AREA OF INDIVIDUAL METALLIC OUTLET OR SWITCH BOXES SHOULD NOT EXCEED 16 SQIN. THE AGGREGATE SURFACE AREA OF THE BOXES SHOULD NOT EXCEED 100 SQ IN. PER 100 SQ FT OF WALL SURFACE. THE AGGREGATE SURFACE AREA OF THE BOXES MAY BE EXCEEDED WHEN WALL-OPENING PROTECTIVE MATERIALS (PER UL CLIV) ARE INSTALLED ACCORDING TO THE REQUIREMENTS OF THEIR CERTIFICATION. 2. METALLIC BOXES LOCATED ON OPPOSITE SIDES OF WALLS OR PARTITIONS SHOULD BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 IN. THIS MINIMUM SEPARATION DISTANCE BETWEEN METALLIC BOXES MAY BE REDUCED WHEN WALL-OPENING PROTECTIVE MATERIALS (PER UL CLIV) ARE INSTALLED ACCORDING TO THE REQUIREMENTS OF THEIR CERTIFICATION. FIRE-STOPPING SUBMITTAL METAL BACK BOX PROTECTION FLEXIBLE CONDUIT OR PIPE 1 2 W-L-1243 W-L-1243 5 CFM / SF 5 CFM / SF WHERE THE PENETRATING ITEM IN THE INDIVIDUAL DESIGN IS INDICATED AS A METALLIC PIPE, CONDUIT, TUBE, DUCT OR CABLE, AND THE FIRESTOP SYSTEM CONSISTS AT MINIMUM OF A FILL MATERIAL (SUCH AS SEALANTS, PUTTY OR MORTAR) , THE PENETRANT MAY PASS THROUGH THE OPENING IN THE WALL OR FLOOR ASSEMBLY AT ANY ANGLE, PROVIDED THE ANNULAR SPACE IS MAINTAINED ON BOTH SIDES OF THE WALL OR FLOOR ASSEMBLY AND ALL OTHER SPECIFICATIONS IN THE DESIGN ARE SATISFIED . IN ALL OTHER CASES, EXCEPT WHERE OTHERWISE INDICATED IN THE SYSTEM, THE PENETRATING ITEM SHOULD PENETRATE THE WALL OR FLOOR ASSEMBLY AT A 90° ANGLE. THROUGH-PENETRATION FIRESTOP SYSTEMS PARTITION TYPE TAG MODIFIER (ADDITIONAL DESIGNATIONS) STUD SIZE PARTITION TYPE HOURLY FIRE RATING (A DASH (-) INDICATES A NON-RATED PARTITION.) 1. PARTITION TYPES SHOWN THIS SHEET REFER TO BASE WALL ONLY. REFER TO OTHER SCHEDULES AND DETAILS FOR FINISHES. 2. REFER TO FLOOR PLANS FOR LOCATIONS AND IDENTIFICATION OF ALL FIRE RESISTANCE AND / OR SMOKE RATED PARTITIONS. 3. IDENTIFY ALL FIRE RESISTANCE AND / OR SMOKE RATED PARTITIONS WITH LABELS 12 INCHES ABOVE THE CEILING OR 10 FEET MAX. ABOVE THE FLOOR IF NO CEILING. USE 1 1/2" HIGH LETTERS, CLEARLY LEGIBLE & READABLE AGAINST A CONTRASTING BACKGROUND. 4. UL DESIGN NUMBERS REFER TO THE UNDERWRITERS FIRE LABORATORY RESISTANCE DIRECTORY, LATEST EDITION. 5. FIRE RESISTANCE RATED PARTITIONS TO HAVE FIRESTOPPING SEALANT AT THE HEAD, SILL, AND JUNCTURES WITH DISSIMILAR MATERIALS, SUCH AS PIPES, DUCTS, CONDUITS, ETC. 6. NON-RATED PARTITIONS TO HAVE ACOUSTICAL SEALANT CONTINUOUS AT THE HEAD, SILL, AND JUNCTURES WITH DISSIMILAR MATERIALS AND ALL AROUND PENETRATIONS AND OPENINGS. 7. REFER TO THE GYPSUM BOARD MATERIAL SCHEDULE THIS SHEET FOR A DESCRIPTION OF THE TYPE OF GYPSUM BOARD PANELS AND WHERE THEY ARE USED. 8. STC RATINGS SHOWN ARE BASED ON LABORATORY TESTED ASSEMBLIES AND WILL NOT NECESSARILY REFLECT THE ACTUAL PERFORMANCE OF THE COMPLETED PARTITIONS. 9. LIMITING HEIGHT INDICATES GIVE THE MAXIMUM UNSUPPORTED HEIGHT FOR THAT PARTITION TYPE BASED ON A DEFLECTION CRITERIA RATION OF L/240. WHERE FLOOR TO STRUCTURE HEIGHT OF PARTITION EXCEEDS THE INDICATED LIMITING HEIGHT, PROVIDE SUPPLEMENTAL BRACING TO THE STRUCTURE OVERHEAD AS REQUIRED TO MAINTAIN DEFLECTION RATIO WITHIN L/240. 10. FOR PARTITION WITH "BRITTLE" FINISHES SUCH AS PLASTER AND CERAMIC TILE, DESIGN PARTITION SYSTEM TO MAINTAIN DEFLECTION RATIO WITH L/360. 1. ADDITIONAL DESIGNATION 'X' TO PARTITION TYPE INDICATES ADDITIONAL LAYER 5/8" GYP. BD. EACH FINISHED SIDE. 2. ADDITIONAL DESIGNATION 'S' TO PARTITION TYPE INDICATES ACCOUSTICAL INSULATION IN STUD SPACE FULL HEIGHT. 3. ADDITIONAL DESIGNATION 'L' TO PARTITION TYPE INDICATES LEAD SHIELDING REQUIREMENT WITH THICKNESS PER PHYSICIST REPORT. PARTITION TYPE MODIFIER NOTES: PARTITION NOTES: GYPSUM WALL BOARD SCHEDULE 5/8" TYPE "X" GYPSUM BOARD ALL PARTITIONS UNO BELOW, OR OTHERWISE ON FLOOR PLANS PROVIDE BEHIND ALL PLUMBING FIXTURES (WATER CLOSETS, URINALS, LAVATORIES, EWC'S, ETC) TO A HEIGHT OF 4' AFF AND 8' WIDE (CENTER ON FIXTURE) PARTITIONS EXPOSED DIRECTLY TO RUNNING WATER & SCHEDULED TO RECEIVE TILE. EXAMPLES: SHOWERS, BATHTUB ENCLOSURE USE AT ALL TOILET ROOMS, HOUSEKEEPING / JANITOR CLOSETS. 5/8" MOLD, WATER, ABUSE & FIRE RESISTANT GYPSUM BOARD 1/2" CEMENTITIOUS OR 5/8" TILE BACKER BOARD 5/8" TYPE "X" MOISTURE RESISTANT 5/8" ABUSE & FIRE RESISTANT GYPSUM BOARD AS INDICATED ON PLANS 5/8" THICK LEAD BACKED GYP. BD (RAY-BAR TYPE "RB-LBG" INSTALLED VERTICALLY, OR EQUAL) AS INDICATED ON PLANS. SEE LEAD SHIELDING SHEET Q8-11 1 A4L (NON-STRUCTURAL INTERIOR PARTITION) PARTIAL HEIGHT GYP. BD. EACH SIDE WITH OPTIONS FOR FULL HEIGHT STUD (BRACING CAN BE USED AS AN ALTERNATE WHERE FIELD CONDITIONS DO NOT ALLOW FULL HEIGHT STUDS) TYPE B PARTITION TYPE LIMITING HT 16" OC B1 B2 B3 B4 B6 3/ 4 " CONT ACOUS SEALANT TYP. BOTH SIDES OVERHEAD STRUCTURE RUNNER TOP OF METAL STUD 4" . . . 5 1/4" . B6 B4 B3 B2 B1 2 1/2" 18 GA METAL STUD (250S162-43) @ 16" O.C. 3 5/8" 16 GA METAL STUD (362S162-54) @ 16" O.C. 4" 16 GA METAL STUD (400S162-54) @ 16" O.C. 1 5/8" 20 GA METAL STUD (162S162-33) @ 16" O.C. 9'-6" 12'-6" 16'-0" 17'-3" 20'-0" 02 A5-02 07 A5-02 08 A5-02 03 A5-02 ALT. ALT. 4 7/8" 3 3/4" 7 1/4" 2 7/8" 5/8" THICK LEAD BACKED GYP. BD. (WHERE OCCURS - SEE WALL TYPE MODIFIERS) ACOUSTICAL BATT INSULATION (WHERE OCCURS - SEE WALL TYPE MODIFIERS) 6" 16 GA METAL STUD (600S162-54) @ 16" O.C. (NON-STRUCTURAL INTERIOR FURRING) PARTIAL HEIGHT GYP. BD. WITH OPTIONS FOR FULL HEIGHT STUD (BRACING CAN BE USED AS AN ALTERNATE WHERE FIELD CONDITIONS DO NOT ALLOW FULL HEIGHT STUDS) TYPE C PARTITION TYPE LIMITING HT 16" OC C1 C2 C3 C4 C6 3/ 4 " CONT ACOUS SEALANT TYP. BOTH SIDES OVERHEAD STRUCTURE RUNNER TOP OF METAL STUD 4" . . . . . C6 C4 C3 C2 C1 2 1/2" 16 GA METAL STUD (250S162-54) @ 16" O.C. 3 5/8" 16 GA METAL STUD (362S162-54) @ 16" O.C. 4" 16 GA METAL STUD (400S162-54) @ 16" O.C. 6" 16 GA METAL STUD (600S162-54) @ 16" O.C. 1 5/8" 16 GA METAL STUD (162S162-54) @ 16" O.C. 9'-6" 12'-6" 16'-0" 17'-3" 20'-0" 3 1/8" 2 1/4" 4 5/8" 02 A5-02 07 A5-02 08 A5-02 02 A5-03 ALT. ALT. 5/8" THICK LEAD BACKED GYP. BD. (WHERE OCCURS, SEE LEAD SHIELDING SHEET Q8-11) ACOUSTICAL BATT INSULATION (WHERE INDICATED) 6 5/8" 4 1/4" R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:22:45 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A5-01 DETAILS - PARTITION TYPES CA361 1 - - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 N/ATHROUGH PENETRATION FIRESTOPS 03 N/APARTITION TYPE NOTES 013" = 1'-0"PARTITION TYPE B 06 3" = 1'-0"PARTITION TYPE C 08 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 NOTE: 1. LATERAL BRACING REQUIRED ONLY AT WALLS WITH A SINGLE SIDE FINISH, WALLS WITH NO FINISH, OR WHERE INDICATED ON THE PLANS. 2. NOTCHING OR CUTTING OF COLD-ROLLED CHANNEL IS NOT PERMITTED FOR ANY CONDITION WHERE BRACING TERMINATES @ BUILT UP JAMB, EXTEND CRC INTO PUNCH OUT 1 1/2"x2"x16 GA. CLIP ANGLE @ EA. STUD - ANGLE TO BE 1/4" LESS THAN STUD WIDTH W/ (2) #8 SMS, EA. LEG, TYP. LATERAL BRACING: CONT. 1-1/2" 16 GA. COLD ROLLED CHANNEL (CRC) @ 48" O.C. MAX LATERAL BRACING SPLICE: 12" LONG CRC INVERTED OVER CENTER OF SPLICE W/ (3) #8 SMS EA. SIDE OF SPLICE METAL STUD 16" O.C. PER PARTITION TYPE, TYP. MAX. 1/4" WHERE OPENINGS INTERRUPT 16 GA BACKING STUDS, TREAT SILL AS LINTEL PER SEAL ALL OPENINGS AROUND DUCT PENTRATIONS THRU RATED PARTITIONS LATERAL BRACING WHERE REQUIRED BACKING PLATE, TYP DUCT OPENING DOOR OPENING SERVICE BOX OPENING WINDOW OPENING SC H E D U L E D C E I L I N G H E I G H T 6" NOTES: 1. MANY TYPICAL PARTITION FRAMING CONDITIONS ARE SHOWN IN COMPOSITE FORM, BUT NOT ALL. FULL HEIGHT WALL BRACED WALL CEILING LINE PROVIDE WALL BRACE AT ALL JAMB CONDITIONS, TYP. WALL BRACE @ 48" O.C., TYP. EXTEND GYP. BD. ABOVE CEILING LINE 09 A5-02 14 A5-02 TYPE 'X' GYP. BD. TYP. 11 A5-02 07 A5-02 06 A5-02 PROVIDE 16 GA. STUDS AT BACKING LOCATIONS, TYP. 11 A5-02 11 A5-02 CEMCO 16 GA. UNPUNCHED KING STUD WITH 3" WIDE FLANGE AND 7/8" STIFFENING LIP - WIDTH TO MATCH WALL TYPE (ICC ESR-3016) DOOR FRAME FLOOR ANCHOR WITH (2) 0.157 DIA. HILTI X-U SHOTPINS WITH 1" EMBED (ESR-2269) ALTERNATE FLOOR ANCHOR: (2) 1/4" DIA. HILTI KH-EZ SCREWS WITH 1-5/8" EMBED (ESR-3027) DOOR FRAME JAMB ANCHOR - PROVIDE (1) ANCHOR FOR EVERY 2'-0" OF JAMB LENGTH - ANCHOR WITH (2) #10 SMS WELDED HOLLOW METAL FRAME - SEE DOOR SCHEDULE (2) #10 SMS EACH SIDE 1/2" MINIMUM PER NFPA 80 CONT. METAL TRACK ANCHOR WITH (2) 0.157 DIA. HILTI X-U SHOTPINS WITH 1" EMBED (ESR-2269) - MAINTAIN MIN. EDGE DISTANCES LWC OVER SLAB ON GRADE 2" 4" MA X I M U M O F 1 2 " 3" 3" (4) #10 SMS EACH SIDE OF SPLICE CENTERLINE OF TOP TRACK SPLICE (6) #10 SMS 1" 1" 1" CUT BRACE FLANGE AND BEND WEB NESTED TRACK OF SAME THICKNESS FOR SPLICING ALTERNATE BRACES IF POSSIBLE METAL STUD 16" O.C. PER PARTITION TYPE, TYP. #10 SMS EA SIDE @ EA. STUD CONT. TOP TRACK 362S162-43 METAL STUD BRACE 48" O.C. SPACING AND AT ALL JAMB STUDS AND TRACK SPLICES 9'-0" MAX S P A N 1" 08 A5-02 FOR TOP CONNECTION SEE DETAIL: CRIPPLE STUD - ATTACH TO JAMB WITH (3) #10 SMS UNPUNCHED TRACK - SIZE AND GAUGE TO MATCH WALL STUD CEMCO 16 GA. UNPUNCHED KING STUD WITH 3" WIDE FLANGE AND 7/8" STIFFENING LIP - WIDTH TO MATCH WALL TYPE (ICC ESR-3016) CONT. METAL TRACK PROVIDE 0.157 DIA HILTI X-U SHOTPIN WITH 1" EMBED @ EACH JAMB STUD, TYP. CRIPPLE STUDS - ANCHOR TO TRACK WITH #10 SMS EACH FACE, TOP AND BOTTOM (2) #10 SMS EA SIDE PRO-X SILL PER SCHEDULE (ICC ESR-1765) 3"x16 GA. UNPUNCHED KING STUD, TYP. PRO-X CLIP -ATTACH TO JAMB WITH (4) #10 SMS (2) #10 SMS TO PRO-X CLIP (2) #10 SMS EACH SIDE TO PRO-X CLIP PRO-X HEADER PER SCHEDULE (ICC ESR-1765) 3"x16 GA. UNPUNCHED KING STUD, TYP. PRO-X CLIP -ATTACH TO JAMB WITH (4) #10 SMS FOR 3-5/8" AND 4" STUDS. PROVIDE (6) #10 SMS FOR 6" AND 8" STUDS (2) #10 SMS TO PRO-X CLIP (2) #10 SMS EACH SIDE TO PRO-X CLIP PRO-X HEADER AND INSERT PER SCHEDULE (ICC ESR-1765) 3"x16 GA. UNPUNCHED KING STUD, TYP. PRO-X CLIP -ATTACH TO JAMB WITH (4) #10 SMS FOR 3-5/8" AND 4" STUDS. PROVIDE (6) #10 SMS FOR 6" AND 8" STUDS (2) #10 SMS TO PRO-X CLIP (2) #10 SMS EACH SIDE TO PRO-X CLIP HEADER WITH INSERT TO JAMB HEADER WITHOUT INSERT TO JAMB SILL TO JAMB #10 SMS @ 8" O.C. TO CONNECT INSERT TO HEADER STYLE: 'X' STYLE: 'XT' STYLE: 'XTC' STYLE: 'CLIP' NOTES: • MAX WALL HEIGHT FOR THIS SYSTEM IS 16'-0" • HEADERS HEIGHTS TO BE 7'-2" OR GREATER • USE 54 MIL. MATERIAL THICKNESS FOR HEADERS -SILLS TO MATCH WALL STUD GAUGE. • USE CHART ABOVE TO SELECT HEADER SIZE BASED ON WALL STUD WIDTHS AND OPENING SPAN. • FOR WINDOWS AND OVERHEAD HVAC OPENING USE SAME MEMBER SELECTION AS DOORS. • PRO-X HEADER SYSTEM BY BRADY CONSTRUCTION INNOVATIONS INC. CONFORMS TO ICC ESR-1765 • ALL PRO-X CLIPS ARE 54 MIL. • MAXIMUM GAP BETWEEN END OF PRO-X HEADER AND JAMB TO BE 3/8" EACH SIDE. • ALL FASTENERS CAN BE INSTALL IN EITHER DIRECTION (I.E. CLIP TO JAMB OR JAMB TO CLIP) • SCREWS SHALL BE #10 SMS WITH SUFFICIENT LENGTH TO ENSURE PENETRATION INTO STEEL STUD BY AT LEAST 3 FULL DIAMETER THREADS HEADER / SILL SCHEDULE FOR WALLS (NON-RATED AND 1-HOUR) I = 1.0, L/240 LATERAL LOADS MIN. 5 PSF PER 2016 CBC 1607.14 or 1607A.14 STUD SIZE MODEL TYPE ALLOW. SPAN MODEL UP TO 4'-6"4'-7" TO 6'-6" ALLOW. SPAN MODEL 6'-7" TO 8'-6" ALLOW. SPAN MODEL 8'-7" TO 10'-6" ALLOW. SPAN MODEL 10'-7" TO 12'-0" ALLOW. SPAN MODEL 3-5/8" = 362 4" = 400 6" = 600 8" = 800 362X425-33 400X425-33 600X425-33 800X425-33 362X425-54 400X425-54 600X425-43 800X425-43 362X425-68 400X425-68 600X425-54 800X425-54 362XTC425-54 400XTC425-54 600X425-68 800X425-68 362XTC425-68 400XTC425-68 600XTC425-54 800XTC425-54 (E) FULL HEIGHT WALL (E) BRACED WALL PROVIDE (N) WALL BRACE AT ALL JAMB CONDITIONS, TYP. (E) WALL BRACE 07 A5-02 (N) DOOR OPENING 14 A5-02 11 A5-02 (E) METAL STUD FRAMING (E) STRUCTURE (E) GYP. BD. FINISH LINE OF (E) CEILING SUPPORT (E) FRAMING UNTIL (N) HEADER IS INSTALLED (N) HEADER (E) HEADER (E) CONT. METAL TRACK (E) CONT. METAL TRACK (E) GYP. BD. FINISH (N) GYP. BD. FINISH TO MATCH THICKNESS OF (E) (E) METAL STUD FRAMING (N) METAL STUD FRAMING @ 16" O.C. TO MATCH WIDTH OF (E) METAL STUD FRAMING (N) METAL TRACK TO MATCH THICKNESS OF (E) - ATTACH TO STRUCT. W/ 0.157" DIA. HILTI X-U SHOTPINS @ 24" O.C. AND 6" FROM ENDS (N) METAL TRACK TO MATCH THICKNESS OF (E) - ATTACH TO (E) HEADER WITH (2) #10 SMS @ 12" O.C. CUT BACK (E) GYP. BD. TO CENTERLINE OF (E) KING STUD AND RE-FASTEN EDGE ATTACH (N) STUD TO (E) WITH (2) #10 SMS @ 16" O.C. REMOVE AND RE- INSTALL GYP. BD. FINISH AS NECESSARY TO INSTALL NEW FRAMING MEMBERS NOTE: 1. MAY BE USED FOR ATTACHMENT OF CABINETS OR EQUIPMENT DISTRIBUTING 80# OR LESS TO EACH STUD, OR GRAB BARS LOADS OF 250# APPLIED IN ANY DIRECTION. 2. NOTCHING OR CUTTING OF BACKING PLATE IS NOT PERMITTED EXCEPT AS SHOWN 3. EXTEND BACKING ONE STUD BAY BEYOND END OF CABINET OR EQUIPMENT METAL STUD 16" O.C. PER PARTITION TYPE, TYP. (3) #10 SMS @ EACH END OF BACKING TRACK @ EACH STUD (3) #10 SMS @ EACH STUD CUT TOOP AND BOTTOM FLANGES OF TRACK AT EACH STUD, TYP. MIN. 600T150-54 UNPUNCHED BACKING TRACK. EXTEND BACKING TO NEXT STUD ST U D S H A L L B E I N D E X E D 10 " M I N . LWC OVER SLAB ON GRADE SECURE MTL. STUD TO TRACK W/ #10 S.M.S., TYP. CONT. METAL TRACK TO MATCH STUD GAUGE AND SIZE W/ 0.157 DIA HILTI X-U SHOTPINS WITH 1" EMBED @ 8" O.C. (ICC ESR-2269) METAL STUD 16" O.C. 5/8" GYP. BD. FOR WALL WITH CASEWORK ON ONE OR BOTH SIDES USE 3/8" DIA. HILTI KB TZ 2 WITH 2" EMBED @ 24" O.C. (ICC ESR-4266) THERMAL OR BATT INSULATION WHERE OCCURS -SEE PARTITION TYPES AT RATED WALLS PROVIDE FIRE SEALANT PER UL JOINT ASSEMBLY BW-S-0001 CONT. ACOUSTIC SEALANT PER PLANS PARTITION TYPE 6" X 16 GA. METAL STUD EACH SIDE PARTITION WALL STUD @ 16" O.C. (2) ROWS OF #10 SMS @ 4" O.C. TOP AND BOTTOM, STAGGERED #10 SMS EACH SIDE @ 16 O.C. #10 SMS EACH SIDE @ EACH STUD B. HEAD AT OPENING 4'-0" TO 10'-0" MAX. PARTITTION WALL STUD @ 16" O.C. 20 GA. UNPUNCHED TRACK #10 SMS EACH SIDE @ EACH STUD 16GA UNPUNCHED STUD TRACK 16GA HEADER STUD #10 SMS EA. SIDE @ 16" O.C. A. HEAD AT OPENING 4'-0" MAX. TRACK WHERE OCCURS 16GA UNPUNCHED TRACK PARTITION TYPE SEE PLAN FOR 16GA UNPUNCHED TRACK PARTITION TYPE SEE PLAN FOR (2) ROWS OF #10 SMS @ 4" O.C. STAGGERED #10 S.M.S. TYP. BOXED HEADER SEE OPTION A ON DETAIL CUT STUD FLANGE & BEND WEB TO FORM 1 1/4" RETURN AT BOTTOM OF HEADER CRIPPLE WALL STUD CUT TRACK FLANGE & BEND WEB TO FORM 1 1/4" RETURN AT TOP OF HEADER. FASTEN (2) #10 SMS, TYP. SE E N O T E 1 "H E A D E R Z O N E " NOTE 1: NO STUD PUNCHES OR HOLES SHALL OCCUR WITHIN 10" ABOVE OR BELOW THE HEADER OR SILL OR INSIDE THE HEADER OR SILL ZONE. JAMB STUD PER DETAIL #10 S.M.S. TYP. BOXED HEADER SEE OPTION B ON DETAIL CUT TRACK FLANGE & BEND WEB TO FORM 1 1/4" RETURN AT BOTTOM OF HEADER CRIPPLE WALL STUD CUT TRACK FLANGE & BEND WEB TO FORM 1 1/4" RETURN AT TOP OF HEADER. FASTEN (2) #10 SMS, TYP. SE E N O T E 1 "H E A D E R Z O N E " (3) #10 S.M.S. EACH SIDE OF HEADER WEB. JAMB STUD PER DETAIL 15 A5-02 15 A5-02 14 A5-02 14 A5-02 CONT. RUNNER TRACK SECURE TO MTL. STUD W/ #10 S.M.S. SECURE TOP TRACK TO NEW 2X4 W/ (2) #12 FHWS, 16" O.C. (E) STRUCTURE, PERPENDICULAR, @ 16" O.C.2x4 W/ (2) #12 x 1-1/2" FHWS EA END TO (E) FLOOR JOIST OR TJI @ 16" O.C. 1-HR RATED PARTITION PER UL U465 4X14 (E) STRUCTURE CONT. RUNNER TRACK SECURE TO MTL. STUD W/ #10 S.M.S. SECURE TOP TRACK TO (E) TJI OR NEW 2X4 W/ (2) #12 FHWS, 16" O.C. (E) TJI, PARALLEL, @ 16" O.C. 2x4 W/ (2) #12 x 1-1/2" FHWS EA END TO (E) FLOOR JOIST OR TJI @ 16" O.C. (E) TJI, PERPENDICULAR, @ 16" O.C. NOTE: COAT ALL COMBUSTIBLE MATERIAL WITHIN THE PLENUM SPACE WITH FLAME STOP IM INTUMESCENT PAINT TO COMPLY WITH CMC 602.2 4" X 18 GA. MTL. STUD BRACE AT 4'-0" O.C. MAX., CUT FLANGE AND BEND WEB CONT. RUNNER TRACK SECURE TO MTL. STUD W/ #10 S.M.S. SECURE BRACE TO TOP TRACK W/ (2) #10 S.M.S. ALT. POSITION SECURE 4" x 18 GA. MTL STUD BRACE TO 2x4 W/ (2) #12x2" FHWS, OR 16 GA. L3x3x1'-8" LONG W/ (3) #10 SMS. (E) TJI, PERPENDICULAR, @ 16" O.C. BRACE TO ANGLE ATTACHMENT OPTION (3) #10 SMS. SEE PARTITION TYPES FOR INSULATION REQUIREMENTS 5/8" LEAD LINED GYPSUM BOARD - LEAD SHIELDING PER PLAN AND PHYSICISTS RECOMMENDATIONS PROVIDE SHEET LEAD SHIELDING TO MATCH THICKNESS OF ADJACENT WALLS ELECTRICAL DEVICE BOX AND FACEPLATE 2X T H E D E P T H 2X T H E D E P T H DE P T H SECTION DETAIL AT LEAD SHIELDED DEVICE BOX PLAN DETAIL AT LEAD SHIELDED DEVICE BOX 2X DEPTH2X DEPTH SEE PARTITION TYPES FOR INSULATION REQUIREMENTS 5/8" LEAD LINED GYPSUM BOARD - LEAD SHIELDING PER PLAN AND PHYSICISTS RECOMMENDATIONS PROVIDE SHEET LEAD SHIELDING TO MATCH THICKNESS OF ADJACENT WALLS ELECTRICAL DEVICE BOX AND FACEPLATE DEPTH R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:22:49 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A5-02 DETAILS - TYPICAL FRAMING CA361 1 - - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 NTSTYPICAL LATERAL BRACING 09 1/2" = 1'-0"TYPICAL FRAMING ELEVATION 01 NTSTYPICAL DOOR JAMB - AXON 14 3" = 1'-0"WALL BRACE BASE ANCHORAGE 07 NTSTYPICAL WINDOW SILL 06 NTSTYPICAL HEADER FRAMING 11 1/2" = 1'-0"TYPICAL (E) FRAMING ELEVATION 13 NTSTYPICAL BACKING DETAILS 10 3" = 1'-0"TYPICAL WALL BASE ANCHORAGE 02 3" = 1'-0"ALT. HEADER FRAMING 15 1 1/2" = 1'-0"ALT. HEADER FRAMING @ JAMB 16 3" = 1'-0"TYPICAL WALL TOP ANCHORAGE 03 3" = 1'-0"TOP OF WALL ATTACHMENT (PERP. TO JOIST)043" = 1'-0"WALL BRACE TOP ANCHORAGE 08 3" = 1'-0"DEVICE BOX @ LEAD LINED WALLS 18 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 EQ EQ 1' - 0" 2' - 1 0 " 2' - 8 3 / 8 " PROVIDE (N) 6" 16 GA. NOTCHED TRACK BACKING PER DETAIL 10/A5-02 (N) 16 GA. METAL STUDS AT 16" O.C. WITH 5/8" GYP. BD. EA. SIDE 2' - 1 0 " CONCEALED CARRIER ARM,ZURN Z1251 OR EQUAL, CONTRACTOR TO VERIFY EXISTING SINK TYPE AND MODEL PROVIDE (N) 1/4" GYP BD. OVER MOUNTING PLATE TO CREATE A FLUSH SURFACE FOR THE FIXTURE MOUNTING ANCHORED TO WALL USING (1) #12 HILTI SELF- DRILLING SCREW X 3" LONG @ 12" OC, TYP (ICC ESR - 2196) 16 GA. X 6" TRACK BACKING PER 4" 16 GA. X 6" TRACK BACKING PER JOINT SEALANT, TYP. PLAM OVER 3/4" PARTICLE BOARD FRONT , 105 GRAM PAPER WITH RESIN ON 1/2" PARTICLE BOARD SIDES AND BACK, 1/4" MDF BOTTOM FLOORING WITH TOP SET RUBBER BASE - WRAP BASE AT END PANELS (E) GYP.BD PARTITION WITH METAL STUD FRAMING 16"0.C. (20 GA. MINIMUM, VIF) 105 GRAM PAPER WITH RESIN TOP COAT ON 3/4" PARTICLE BOARD, ADJUSTABLE SHELVES, TYP. 2X4 BASE SUPPORT SATIN FINISH, STAINLESS STEEL DOOR HANDLE/PULL, TYP. 1' - 9 3/8" NO DRIP EDGE AND RADIUSED CORNERS 3/4" THICK SOLID SURFACE COUNTER TOP - SEE FINISH SCHEDULE 3/4" PLYWOOD SUBSTRATE 4" H. SOLID SURFACE SPLASH, TYP. SE E E L E V A T I O N S 2' - 0" ANCHORED TO WALL USING (1) #12 HILTI SELF- DRILLING SCREW X 3" LONG @ 12" OC, TYP (ICC ESR - 2196) 20° MATCH EXISTING 1' - 2" F.V. SE E E L E V A T I O N S ANCHORED TO WALL USING (1) #12 HILTI SELF-DRILLING SCREW X 3" LONG @ 12" OC, TYP ( ICC ESR - 2196) (N) STUD WALL WITH 16 GA MIN STUDS @ 16" OC ANCHORED TO TOP TRACK PER 03/A5-02 AND BOTTOM TRACK PER 02/A5-02 16 GA. X 6" TRACK BACKING PER DETAIL SATIN FINISH, STAINLESS STEEL DOOR HANDLE/PULL, TYP. PLAM-2 OVER 3/4" PARTICLE BOARD DOORS. SEE FINISH SCHEDULE. 105 GRAM PAPER WITH RESIN TOP COAT ON 3/4" PARTICLE BOARD, ADJUSTABLE SHELVES, TYP. SLOPED OR FULL-HEIGHT SOFFIT PER ELEVATION. SEE FINISH SCHEDULE. PROVIDE 1X4 CONT. WOOD BLOCKING WITH (1) #14 HEX HEAD SMS @12" O.C., TYP. SELF EDGE, TYP. SATIN FINISH STAINLESS STEEL DOOR HANDLE PLASTIC LAMINATE OVER 3/4" PARTICLE BOARD COUNTER DRAWER UNIT W/ FULL EXTENSION SLIDES, PLASTIC LAMINATE OVER 3/4" PARTICAL BOARD FRONT, 105 GRAM PAPER W/ RESIN ON 1/2" PARTICLE BOARD SIDES AND BACK, 1/4" MDF BOTTOM WALL BASE PROVIDE BACKING PER 3/4" CLEAT DOWELED AND GLUDED TO ENDS. FASTEN TO BACKING W/ # 14 X 3" SELF DRILLING HEXT HEAD FASTENERS @ 12" O.C. BETWEEN CABINET AND BACKING PLATE. (2 1/2" O.C. MAX. FROM END AND MIN. 4 PER CABINET) TYP. 2X BASE SUPPORT, TYP.1' - 8" 5" 4" 1' - 6 " 10 A5-02 PROVIDE #4 DOWELS @ 12" O.C. STAGGERED ALONG EACH FACE, DRILLED AND EPOXIED INTO (E) S.O.G. USING HILTI HIT-RE 500-V3 EPOXY W/ 4" EMBED (ICC ESR-2322). (E) SAND LAYER (E)VAPOR BARRIER (E) 5" THICK (4000 PSI) CONCRETE SLAB ON GRADE W/ #4 @ 12" O.C. EA WAY. ROUGHEN EDGES OF SAWCUT FOR BONDING OF (N) CONCRETE (N) CONCRETE INFILL, 4000 PSI TO MATCH EXISTING OR EQUAL (N) SANITARY, SEE PLUMBING DWGS (N) 15 MIL VAPOR BARRIER TO MATCH EXISTING - TAPE PATCH MATERIAL TO EXISTING WITH MANUFACTURER'S STANDARD JOINT TAPE WITH MANUFACTURER REQUIRED OVERLAPS MIN. 12" CLR 4"4" MIN. 12" CLR PLACE AND COMPACT BEDDING COURSE ON TRENCH BOTTOMS - PLACE AND COMPACT BACKFILL OF SUB- BASE MATERIAL - BACKFILL ABOVE PIPE ZONE SHALL BE COMPACTED TO 90% MAXIMUM DENSITY WHEN SLURRY BACK FILL IS NOT USED (CONTRACTOR'S OPTION TO BACK FILL WITH 2-SACK SLURRY). COMPACTION TESTS SHALL BE TAKEN BY CONTRACTOR AT RANDOM LOCATIONS FOR EVERY 8 INCHES OF LIFT. WRAP PIPE WITH HIGH-DENSITY, CROSS LAMINATED POLYETHYLENE FILM OF 0.004" MIN. THICKNESS FOR PIPES AND CONDUITS 6" DIA. AND LESS, HAND SHAPE TRENCH BOTTOMS TO PROVIDE UNIFORM BEARING AND SUPPORT FOR PIPES AND CONDUIT ON UNDISTURBED SUB-GRADE EXCAVATE TRENCHES 4" DEEPER THAN BOTTOM OF PIPE ELEVATION TO ALLOW FOR BEDDING COURSE WIDTH PER FURN. SCHEDULE LENGTH PER FURN. SCHEDULE FRONT ELEVATION SIDE ELEVATION 1. DESIGN PER KAISER VERNON STANDARD RP 1812, MODULAR ROLLING CART WITH (1) DRAWER ABOVE AND (1) FILE DRAWER BELOW 2. U.N.O., PROVIDE PLASTIC LAMINATE FINISH TO OUTSIDE AND INSIDE, PER FINISH PL-3 SCHEDULE. 3. U.N.O., PROVIDE CHROME FINISH HARDWARE. 4. PROVIDE LOCKS AND CASTORS. 5. QUANTITIES PER FURNITURE SCHEDULE. 6. LOCATIONS PER EQUIPMENT AND FURNITURE PLANS. R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:23:09 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A5-03 DETAILS - MISC. CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 1 1/2" = 1'-0"SINK MOUNTING DETAIL 01 1 1/2" = 1'-0"BASE CABINET 03 1 1/2" = 1'-0"TYPICAL UPPER CABINET 04 1 1/2" = 1'-0"DRESSING BENCH W/ DRAWER 06 1 1/2" = 1'-0"TRENCH REPAIR DETAIL 0207N/AMOBILE PEDESTAL - MOPE 800 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 4' - 0"8' - 0" 12 ' - 0 " 6' - 0 " FIXED END FREE END FR E E E N D FI X E D E N D FROM SPLAY WIRE TO WALL CROSS RUNNERS,TYP. CONT. MAIN RUNNER AT 4'-0" O.C., TYP. 4 WAY 45 DEG. DIAGONAL 12 GA. WIRE BRACING W/ COMPRESSION STRUT LOCATED ON MAIN RUNNER PER DETAIL: 12 GA. VERTICAL HANGER WIRES AT 4'-0" EA. WAY NOTE: 1. CEILING GRID MAY BE ATTACHED TO NOT MORE THAN TWO (2) ADJACENT WALLS AND MUST BE AT LEAST 3/4" FREE OF OTHER WALLS. 2. LOCATE COMPRESSION STRUT FOR EA. 96 S.F. 03/A5-04 FIXTURE SUSPENSION PER DETAIL:04/A5-04 24 GA. CONT. WALL ANGLE, TYP. 8" M A X STABILIZER BARS, CROSS TEES OR STRUTS 8" MAX. FROM WALL TYP. ALONG FREE JOINTS 4' - 0" MAX. SUSPENDED CEILINGS: SEISMIC DESIGN FOR CATEGORIES D THROUGH F (ASCE 7): 1. SUSPENSION SYSTEM COMPONENTS SHALL COMPLY WITH ASTM C635 AND E580 SECTION 5.1 AS MODIFIED BY CBC 1616A.1.21: • THE CEILING GRID SYSTEM SHALL BE RATED HEAVY DUTY AS DEFINED BY ASTM C635 • HANGER AND BRACING WIRES SHALL BE #12 GAGE (0.106" DIAMETER), SOFT ANNEALED, AND GALVANIZED STEEL WIRES WITH CLASS 1 COATING. THEY MAY BE USED FOR UP TO AND INCLUDING 4'-0"x 4'-0" GRID SPACING ALONG AND ATTACHED TO MAIN RUNNERS. SPLICES ARE NOT PERMITTED IN ANY HANGER WIRE. • MAIN RUNNERS AND CROSS RUNNERS ALONG WITH THEIR SPLICES, INTERSECTION CONNECTORS, AND EXPANSION DEVICES SHALL BE DESIGNED AND CONSTRUCTED TO CARRY A MEAN ULTIMATE TEST LOAD OF NOT LESS THAN 180 LBS. IN COMPRESSION & TENSION, IN ACCORDANCE WITH ASTM 580 SECTION 5.1.2. 2. SUSPENSION SYSTEM INSTALLATION, SHALL COMPLY WITH ASTM C636 AND E580 SECTION 5.2: • PROVIDE #12 GAGE HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN EIGHT (8) INCHES OF THE SUPPORT OR WITHIN ONE-FOURTH (1/4) OF THE LENGTH OF THE END TEE, WHICHEVER IS LESS, FOR THE PERIMETER OF THE CEILING AREA. PERIMETER WIRES ARE NOT REQUIRED WHEN THE LENGTH OF THE END TEE IS EIGHT (8) INCHES OR LESS. • CEILING GRID MEMBERS SHALL BE ATTACHED TO TWO (2) ADJACENT WALLS, IN ACCORDANCE WITH ASTM E580 SECTION 5.2.3. CEILING GRID MEMBERS SHALL BE AT LEAST 3/4" INCH CLEAR OF OTHER WALLS. IF WALLS RUN DIAGONAL TO THE CEILING GRID SYSTEM RUNNERS, ONE END OF MAIN AND CROSS RUNNERS SHOULD BE FREE, AND A MINIMUM OF 3/4 INCH CLEAR OF WALL. • THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN TWO (2) INCHES. USE OF ANGLES WITH SMALLER WIDTHS IN CONJUNCTION WITH PERIMETER CLIPS SHALL REQUIRE AN ALTERNATE METHOD OF COMPLIANCE WITH ADEQUATE JUSTIFICATION AND ARE OUTSIDE THE SCOPE OF THIS PROJECT. • AT THE PERIMETER OF THE CEILING AREA WHERE MAIN OR CROSS RUNNERS ARE NOT CONNECTED TO THE ADJACENT WALL, PROVIDE INTERCONNECTION BETWEEN THE RUNNERS AT THE FREE END TO PREVENT LATERAL SPREADING. A METAL STRUT OR A #16 GAGE WIRE WITH A POSITIVE MECHANICAL CONNECTION TO RUNNER MAY BE USED. WHERE THE PERPENDICULAR DISTANCE FROM THE WALL TO THE FIRST PARALLEL RUNNER IS EIGHT (8) INCHES OR LESS, THIS INTERCONNECTION IS NOT REQUIRED. 3. EXPANSION JOINTS, SEISMIC SEPARATIONS, AND PENETRATIONS: • EXPANSION JOINTS SHALL BE PROVIDED IN THE CEILING AT INTERSECTIONS OF CORRIDORS AND AT JUNCTIONS OF CORRIDORS WITH LOBBIES OR OTHER SIMILAR AREAS. • FOR CEILING AREAS EXCEEDING 2500 SQUARE FEET, A SEISMIC SEPARATION JOINT SHALL BE PROVIDED TO DIVIDE THE CEILING INTO AREAS NOT EXCEEDING 2500 SQ. FT. • PENETRATIONS THROUGH THE CEILING FOR SPRINKLER HEADS AND OTHER SIMILAR DEVICES THAT ARE NOT INTEGRALLY TIED TO THE CEILING SYSTEM IN THE LATERAL DIRECTION SHALL HAVE A TWO (2) INCH OVERSIZED RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FREE MOVEMENT OF ONE (1) INCH IN ALL HORIZONTAL DIRECTIONS. A FLEXIBLE SPRINKLER HOSE FITTING THAT CAN ACCOMMODATE ONE (1) INCH OF CEILING MOVEMENT SHALL BE PERMITTED TO BE USED IN LIEU OF THE OVERSIZED RING, SLEEVE OR ADAPTER. SUCH FLEXIBLE SPRINKLER HOSE SHALL BE ADEQUATELY SUPPORTED FROM SOFFIT SO AS NOT TO EXCEED THE MAXIMUM TRIBUTARY WEIGHT OF THE CEILING. 4. CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE BRACING. 5. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING. 6. SUSPENDED CEILINGS SHALL BE SUBJECT TO THE SPECIAL INSPECTION REQUIREMENTS OF CBC 1707A.6 IN ACCORDANCE WITH ASCE 7-05 SECTION 11A.1.3.9. CEILING FIXTURES, TERMINALS, AND DEVICES: a. CEILING PANELS SHALL NOT SUPPORT ANY LIGHT FIXTURES, AIR TERMINALS/GRILLS, OR OTHER DEVICES(REFERRED TO ALL BY COMMON TERM FIXTURES HERE AFTER). b. ALL FIXTURES SHALL BE MOUNTED IN A MANNER THAT WILL NOT COMPROMISE CEILING PERFORMANCE. c. ALL FIXTURES SHALL BE ATTACHED TO THE SUSPENDED CEILING SYSTEM BY MECHANICAL MEANS, UNLESS INDEPENDENTLY SUPPORTED. THE ATTACHMENT DEVICE SHALL HAVE THE CAPACITY OF 100% OF FIXTURE WEIGHT ACTING IN ANY DIRECTION. A MINIMUM OF TWO ATTACHMENT DEVICES ARE REQUIRED FOR EACH FIXTURE. d. SURFACE MOUNTED FIXTURES SHALL BE ATTACHED TO THE MAIN RUNNER WITH POSITIVE CLAMPING DEVICES MADE OF MATERIAL WITH A MINIMUM 14 GAGE. A NO.12 GAUGE SAFETY WIRES SHALL BE ATTACHED BETWEEN THE CLAMPING DEVICE AND TO THE STRUCTURE ABOVE. IN NO CASE SHALL THE FIXTURES EXCEED THE DESIGN CAPACITY OF THE SUPPORTING MEMBERS. e. ALL FIXTURES WEIGHING LESS THAN OR EQUAL TO 10 LB. SHALL HAVE ONE NO. 12 GAUGE SAFETY WIRE CONNECTED FROM FIXTURE HOUSING TO STRUCTURE ABOVE. IT IS NOT NECESSARY FOR THESE SAFETY WIRES TO BE TAUT. f. ALL FIXTURES WEIGHING GREATER THAN 10 LB BUT LESS THAN OR EQUAL TO 56 LB. SHALL HAVE TWO NO. 12 GAUGE SAFETY WIRE CONNECTED FROM FIXTURE HOUSING TO STRUCTURE ABOVE. IT IS NOT NECESSARY FOR THESE SAFETY WIRES TO BE TAUT. g. ALL FIXTURES WEIGHING GREATER THAN 56 LB. SHALL BE SUPPORTED DIRECTLY FROM STRUCTURE ABOVE BY APPROVED HANGERS. h. PENDENT-HUNG FIXTURES SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE USING NO LESS THAN N0. 9-GAUGE WIRE OR AN APPROVED ALTERNATE SUPPORT. THE CEILING SUSPENSION SYSTEM SHALL NOT PROVIDE ANY DIRECT SUPPORT. i. ALL RECESSED OR DROP-IN FIXTURES SHALL BE SUPPORTED DIRECTLY FROM FIXTURE HOUSING TO THE STRUCTURE ABOVE WITH A MINIMUM OF TWO NO. 12 GAUGE WIRES LOCATED AT DIAGONALLY OPPOSITE CORNERS. LEVELING OR POSITIONING OF FIXTURES MAY BE PROVIDED BY CEILING GRID. FIXTURE SUPPORT WIRES MAY BE SLIGHTLY LOOSE TO ALLOW THE FIXTURE TO SEAT IN THE GRID SYSTEM. FIXTURES SHALL NOT BE SUPPORTED FROM MAIN RUNNERS OR CROSS RUNNERS IF THE WEIGHT OF THE FIXTURES CAUSES TOTAL DEAD LOAD TO EXCEED THE DEFLECTION CAPABILITY OF THE CEILING SUSPENSION SYSTEM. (2) 12 GA. SLACK WIRE HANGERS FOR DEVICES THAT WEIGH LESS THAN 56 LBS. (HEAVY DUTY GRID SYSTEM REQUIRED), PLACE ON DIAGONAL CORNERS (2) #8 SMS EA. SIDE HEAVY DUTY GRID SYSTEM HEAVY DUTY GRID SYSTEM HANGER WIRE (WHERE OCCURS)CEILING FIXTURE, TERMINAL, OR DEVICE (56# MAX) LATERAL FORCE BRACING: a. PROVIDE LATERAL-FORCE BRACING ASSEMBLIES CONSISTING OF A STRUT AND FOUR (4) #12 GAGE BRACING WIRES ORIENTED 90 DEGREES FROM EACH OTHER. b. LATERAL-FORCE BRACING ASSEMBLIES SHALL BE SPACED IN ACCORDANCE WITH AND FROM EACH WALL AND AT THE EDGES OF ANY CHANGE OF ELEVATION OF THE CEILING. c. THE SLOPE OF BRACING WIRES MAY BE FROM 10 TO 45 DEGREES BUT MAY NOT EXCEED 45 DEGREES FROM THE PLANE OF THE CEILING AND WIRES SHALL BE TAUT. d. STRUTS SHALL BE ADEQUATE TO RESIST THE VERTICAL COMPONENT INDUCED BY THE BRACING WIRES, AND SHALL NOT BE MORE THAN 1 (HORIZONTAL) IN 6 (VERTICAL) OUT OF PLUMB. EXCEPTION: LATERAL FORCE BRACING MAY BE OMITTED FOR SUSPENDED ACOUSTICAL CEILING SYSTEMS WITH A CEILING AREA OF 144 SQ. FT. OR LESS, WHEN PERIMETER SUPPORT IN ACCORDANCE WITH ASTM E580 ARE PROVIDED AND PERIMETER WALLS ARE DESIGNED TO CARRY THE CEILING LATERAL FORCES. 4 WAY 45 DEG. DIAGONAL 12 GA. WIRE BRACING FOR TOP ATTACHMENT SEE DETAIL: 12 GA. VERTICAL HANGER WIRES AT 4'-0" EA. WAY - FOR TOP ATTACHMENT SEE DETAIL: -/--- -/--- 1-1/2" MAX.1-1/2" MAX. TYP. 3/4" MIN. 1" MAX 400S137-33 (20 GA) CENTERED OVER CROSS RUNNER - SLOT END AS NOTED. FOR TOP ATTACHMENT SEE DETAIL:-/--- CROSS RUNNER MAIN RUNNER (2) 1/4" DIA. MACHINE BOLT TYP. 3/4" MIN. TYP. 10 TO 45° 02/A5-04 WALL STUD (20 GA. MIN.) 5/8" GYP. BD. (2) #10 SMS TO FRAMING 12 GA. HOCL-11 ANGLE CLIP 12 GA. CEILING HANGER WIRE WITH 3 TIGHT TURNS IN 3" BOTH ENDS OF WIRE PER DETAIL 02/A5-04 1 TO 6 MAX. SLOPE FROM VERTICAL NOTE: 1. APPLY DETAIL FOR PERIMETER WIRE ATTACHMENT OR WHERE OBSTRUCTIONS PREVENTS ATTACHMENT TO STRUCTURE ABOVE. 2. WALLS SHALL BE DESIGN FOR HANGER FORCES. (E) STRUCTURE CUT STUD FLANGE AND BEND WEB 90 DEG. ATTACH TRACK TO (E) STRUCTURE ABOVE OR NEW 2X4 WITH (2) #12X2" FHWS. (E) PLYWOOD DECK 400S137-33 (20 GA) - CUT FLANGES AND BEND (E) STRUCTURE 12 GA. HANGER WIRE W/ (3) TIGHT TURNS. SPLICES NOT PERMITTED 12 GA. BRACE WIRE W/ (3) TIGHT TURNS. SPLICES NOT PERMITTED. 3" FLATHEAD HANGER SCREW (ICC ESR-1153) W/ 1 1/2" MIN. PENETRATION (E) PLYWOOD DECK NOTE: COAT ALL COMBUSTIBLE MATERIAL WITHIN THE PLENUM SPACE WITH FLAME STOP IM INTUMESCENT PAINT TO COMPLY WITH CMC 602.2 NO HANGER OR ATTACHEMENTS OF ANY KIND TO BE MADE TO THE EXISTING PLYWOOD ROOF DECK ATTACHMENT OF HANGER AND BRACING WIRES: a. HANGER WIRE LOOPS SHALL BE TIGHTLY WRAPPED AND SHARPLY BENT TO PREVENT ANY VERTICAL MOVEMENT OR ROTATION OF THE MEMBER WITHIN THE LOOPS. b. SPLICES OF WIRES ARE NOT PERMITTED. c. HANGER OR BRACING WIRE ANCHORED TO THE STRUCTURE SHOULD BE INSTALLED IN SUCH A MANNER THAT THE DIRECTION OF THE ANCHOR ALIGNS AS CLOSELY AS POSSIBLE WITH THE DIRECTION OF THE WIRE. d. SEPARATE ALL CEILING HANGER AND BRACING WIRES AT LEAST SIX (6) INCHES FROM ALL UNBRACED DUCTS, PIPES CONDUITS, ETC. e. HANGER WIRES SHALL NOT BE ATTACHED TO OR BEND AROUND INTERFERING MATERIAL OR EQUIPMENT. PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT OBSTRUCTIONS TO TYPICAL HANGER SPACING. PROVIDE ADDITIONAL HANGERS, STRUTS OR BRACES AS REQUIRED AT ALL CEILING BREAKS, SOFFITS, OR DISCONTINUOUS AREAS. f. HANGER WIRES THAT ARE MORE THAN 1 (HORIZONTAL) IN 6 (VERTICAL) OUT OF PLUMB SHALL REQUIRE PROJECT SPECIFIC DESIGN. NOTE: 1. PROVIDE 12 GAGE HANGER WIRES AR THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN EIGHT (8) INCHES OF THE SUPPORT OR WITHIN ONE-FOURTH (1/4) OF THE LENGTH OF THE END TEE, WHICHEVER IS LESS, FOR THE PERIMETER OF THE CEILING AREA. PERIMETER WIRES ARE NOT REQUIRED WHEN THE LENGTH OF THE END TEE IS EIGHT (8) INCHES OR LESS. 2. NAILS AT ENDS OF HORIZONTAL STRUTS ARE TO BE PLACED WITH NAIL HEAD TOWARD CENTER LINE OF SPAN OF STRUT. 3. SPACERS MAY BE SLOTTED APPROVED ANGLES OR CHANNELS WITH "DIAMOND POINTS" OF SPRING STEEL WHICH SNAP TIGHT TO PREVENT MOVEMENT OF STRUT. 4. STEEL POP RIVETS SHALL HAVE MINIMUM ALLOWABLE SHEAR STRENGTH OF 120# AND ULTIMATE SHEAR STRENGTH OF 300#. 5. REFER TO ICC-ESR-1308. STEEL POP RIVET AT ATTACHED SIDE ONLY MAIN OR CROSS RUNNER HANGER WIRE CEILING PANEL 7/8"x1" 24 GA CONT. PERIMETER ANGLE W/ (1) #10 SMS INTO WALL STUDS (24" O.C. MAX) CONT. SLOTTED ANGLE STRUT SPACER W/ HORIZ. 6d RINGSHANK NAIL FREE END FIXED END BERC2 SLIP CLIP 8" MAX 8" MAX FURRING CHANNEL SPLICE MAIN RUNNER SPLICE 16" 12" MIN OVERLAP PROVIDE (4) #8 SMS AT EACH END OF OVERLAP. (8) TOTAL. 1-1/2" 16 GA. MAIN RUNNER INSTALLED BACK TO BACK. PROVIDE (2) #8 SMS AT EACH END OF OVERLAP. (4) TOTAL. 8" 7-1/4" TYP. 3/8" TYP. 1-1/2" 16 GA. MAIN RUNNER. MIN. 8" MAX.SADDLE TIED TO MAIN RUNNERS WITH 16 GAGE TIE WIRE OR A DOUBLE STRAND OF 18 GAGE TIE WIRE LATERAL FORCE BRACING: a. PROVIDE LATERAL-FORCE BRACING ASSEMBLIES CONSISTING OF A STRUT AND FOUR (4) #12 GAGE BRACING WIRES ORIENTED 90 DEGREES FROM EACH OTHER. b. LATERAL-FORCE BRACING ASSEMBLIES SHALL BE SPACED IN ACCORDANCE WITH AND FROM EACH WALL AND AT THE EDGES OF ANY CHANGE OF ELEVATION OF THE CEILING. c. THE SLOPE OF BRACING WIRES MAY BE FROM 10 TO 45 DEGREES BUT MAY NOT EXCEED 45 DEGREES FROM THE PLANE OF THE CEILING AND WIRES SHALL BE TAUT. d. STRUTS SHALL BE ADEQUATE TO RESIST THE VERTICAL COMPONENT INDUCED BY THE BRACING WIRES, AND SHALL NOT BE MORE THAN 1 (HORIZONTAL) IN 6 (VERTICAL) OUT OF PLUMB. EXCEPTION: LATERAL FORCE BRACING MAY BE OMITTED FOR SUSPENDED ACOUSTICAL CEILING SYSTEMS WITH A CEILING AREA OF 144 SQ. FT. OR LESS, WHEN PERIMETER SUPPORT IN ACCORDANCE WITH ASTM E580 ARE PROVIDED AND PERIMETER WALLS ARE DESIGNED TO CARRY THE CEILING LATERAL FORCES. 4 WAY 45 DEG. DIAGONAL 12 GA. WIRE BRACING FOR TOP ATTACHMENT SEE DETAIL: 12 GA. VERTICAL HANGER WIRES AT 4'-0" EA. WAY - FOR TOP ATTACHMENT SEE DETAIL: -/--- -/--- 400S137-33 (20 GA) CENTERED OVER CROSS RUNNER - FOR TOP ATTACHMENT SEE DETAIL: -/--- GYP. BD. FINISH FURRING CHANNEL 10/A5-04 2" MAX #8 SMS TO PREVENT SLIPPAGE OF BRACE WIRES PARALLEL TO MAIN RUNNER, TYP. (2) #10 SMS 3" MAX MAIN RUNNER 4' - 0" MAX MAX 8' - 0" 12' - 0" MAX 6'-0" MAX FIXED END FREE END FR E E E N D FI X E D E N D FROM SPLAY WIRE TO WALL FURRING CHANNELS,TYP. CONT. MAIN RUNNER AT 4'-0" O.C., TYP. 4 WAY 45 DEG. DIAGONAL 12 GA. WIRE BRACING W/ COMPRESSION STRUT LOCATED ON MAIN RUNNER PER DETAIL: 12 GA. VERTICAL HANGER WIRES AT 4'-0" EA. WAY NOTE: 1. CEILING GRID MAY BE ATTACHED TO NOT MORE THAN TWO (2) ADJACENT WALLS AND MUST BE AT LEAST 3/4" FREE OF OTHER WALLS. 2. LOCATE COMPRESSION STRUT AND SPLAY WIRES FOR EA. 96 S.F. 03/A5-04 FIXTURE SUSPENSION PER DETAIL:12/A5-04 24 GA. CONT. WALL ANGLE, TYP. 13 A5-04 14 A5-04 CEILING FIXTURES, TERMINALS, AND DEVICES: a. ALL FIXTURES SHALL BE MOUNTED IN A MANNER THAT WILL NOT COMPROMISE CEILING PERFORMANCE. b. ALL FIXTURES SHALL BE SUPPORTED DIRECTLY BY MAIN RUNNERS OR BY SUPPLEMENTAL FRAMING WHICH IS SUPPORTED BY MAIN RUNNERS AND POSITIVELY ATTACHED WITH SCREWS OR OTHER APPROVED CONNECTORS. c. SURFACE MOUNTED FIXTURES SHALL BE ATTACHED TO A MAIN RUNNER WITH POSITIVE CLAMPING DEVICE MADE OF MATERIAL WITH A MINIMUM 14 GAGE. ROTATIONAL SPRING CLAMPS DO NOT COMPLY. d. ALL FIXTURES WEIGHING LESS THAN OR EQUAL TO 10 LB. SHALL HAVE ONE NO. 12 GAUGE SAFETY WIRE CONNECTED FROM FIXTURE HOUSING TO STRUCTURE ABOVE. IT IS NOT NECESSARY FOR THESE SAFETY WIRES TO BE TAUT. e. ALL FIXTURES WEIGHING GREATER THAN 10 LB BUT LESS THAN OR EQUAL TO 56 LB. SHALL HAVE TWO NO. 12 GAUGE SAFETY WIRE CONNECTED FROM FIXTURE HOUSING TO STRUCTURE ABOVE. IT IS NOT NECESSARY FOR THESE SAFETY WIRES TO BE TAUT. f. ALL FIXTURES WEIGHING GREATER THAN 56 LB. SHALL BE SUPPORTED DIRECTLY FROM STRUCTURE ABOVE BY APPROVED HANGERS. g. PENDENT-HUNG FIXTURES SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE USING NO LESS THAN N0. 9-GAUGE WIRE OR AN APPROVED ALTERNATE SUPPORT. THE CEILING SUSPENSION SYSTEM SHALL NOT PROVIDE ANY DIRECT SUPPORT. h. ALL RECESSED OR DROP-IN FIXTURES SHALL BE SUPPORTED DIRECTLY FROM FIXTURE HOUSING TO THE STRUCTURE ABOVE WITH A MINIMUM OF TWO NO. 12 GAUGE WIRES LOCATED AT DIAGONALLY OPPOSITE CORNERS. LEVELING OR POSITIONING OF FIXTURES MAY BE PROVIDED BY CEILING GRID. FIXTURE SUPPORT WIRES MAY BE SLIGHTLY LOOSE TO ALLOW THE FIXTURE TO SEAT IN THE GRID SYSTEM. FIXTURES SHALL NOT BE SUPPORTED FROM MAIN RUNNERS OR FURRING CHANNELS IF THE WEIGHT OF THE FIXTURES CAUSES TOTAL DEAD LOAD TO EXCEED THE DEFLECTION CAPABILITY OF THE CEILING SUSPENSION SYSTEM. i. ACCESS PANELS SHALL HAVE A PERMANENT WARNING LABEL AS FOLLOWS: 1. DO NOT CLIMB, WALK OR CRAWL ON THE GYPSUM BOARD CEILING 2. DO NOT STORE OR STOW ANYTHING ON THE GYPSUM BOARD CEILING (2) 12 GA. SLACK WIRE HANGERS FOR DEVICES THAT WEIGH LESS THAN 56 LBS. PLACE ON DIAGONAL CORNERS (2) #10 SMS EA. END GYPSUM BOARD FINISH HANGER WIRE (WHERE OCCURS) CEILING FIXTURE, TERMINAL, OR DEVICE (56# MAX) WITH POSITIVE ATTACHMENT TO MAIN RUNNERS PROVIDE (1) OR MORE SUPPLEMENTAL 150U050-54 AS REQUIRED. SEE GENERAL NOTE b. - CLIP FLANGE AND BEND BACK TO FORM 'L' CLIP #10 SMS AT EACH MAIN RUNNER MAIN RUNNER HANGER WIRE FURRING CHANNEL 1"x2" 24 GA CONT. PERIMETER ANGLE W/ (1) #10 SMS INTO WALL STUDS (24" O.C. MAX) FREE END FIXED END 6" MAX 6" MAX MIN 1" CLR1/2" MIN 1/2" MIN 4" MAX, TYP #10 SMS AT EACH FURRING CHANNEL MAIN RUNNER HANGER WIRE FURRING CHANNEL 1"x2" 24 GA CONT. PERIMETER ANGLE W/ (1) #10 SMS INTO WALL STUDS (24" O.C. MAX) FREE END FIXED END 6" MAX 6" MAX MIN 1" CLR NO CONNECTION TO FURRING CHANNEL 1/2" MIN 1/2" MIN 1. SUSPENSION SYSTEM COMPONENTS SHALL COMPLY WITH ASTM C754: • MAIN RUNNERS SHALL CONSIST OF 16 GAGE 1-1/2” COLD ROLLED U-CHANNEL 150U050-54 SPACED AT 4’-0” OC MAX. MAIN RUNNERS SHALL BE SUPPORTED BY HANGER WIRES AT 4’-0” OC MAX AND WITHIN 6” FROM EA END. • FURRING CHANNEL SHALL CONSIST OF 25 GAGE 7/8” (HAT) FURRING CHANNELS (087F125-18) AT 2’-0” OC MAX. FURRING CHANNELS SHALL BE SADDLE TIED TO MAIN RUNNERS WITH 16 GAGE TIE WIRE OR A DOUBLE STRAND OF 18 GAGE TIE WIRE IN ACCORDANCE WITH • MAIN RUNNERS AND FURRING CHANNELS SHALL BE SPLICED BY LAPPING IN ACCORDANCE WITH • MAIN RUNNERS AND FURRING CHANNELS ALONG WITH THEIR SPLICES, INTERSECTION CONNECTORS, AND EXPANSION DEVICES SHALL BE DESIGNED AND CONSTRUCTED TO CARRY A MEAN ULTIMATE TEST LOAD OF NOT LESS THAN 270 LBS. IN COMPRESSION & TENSION. • HANGER AND BRACING WIRES SHALL BE #12 GAGE (0.106" DIAMETER), SOFT ANNEALED, AND GALVANIZED STEEL WIRES WITH CLASS 1 COATING. THEY MAY BE USED FOR UP TO AND INCLUDING 4'-0"x 4'-0" GRID SPACING ALONG AND ATTACHED TO MAIN RUNNERS. SPLICES ARE NOT PERMITTED IN ANY HANGER WIRE. • WIRE HANGERS SHALL BE SADDLE-TIED AROUND MAIN RUNNERS SO AS TO PREVENT TURNING OR TWISTING OF THE MEMBER. 2. SUSPENSION SYSTEM INSTALLATION SHALL COMPLY WITH ASTM C754: • CEILING GRID MEMBERS SHALL BE ATTACHED TO TWO (2) ADJACENT WALLS. MAIN RUNNERS AND FURRING CHANNEL SHALL BE AT LEAST 1 INCH CLEAR OF OTHER WALL AND FURRING SHALL BE AT LEAST 3/4” CLEAR OF OTHER WALL. IF WALLS RUN DIAGONAL TO THE CEILING GRID SYSTEM RUNNERS, ONE END OF MAIN RUNNER AND FURRING SHOULD BE FREE WITH STANDARD CLEARANCES. • THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN TWO (2) INCHES. 3. EXPANSION JOINTS, SEISMIC SEPARATIONS, AND PENETRATIONS: • EXPANSION JOINTS SHALL BE PROVIDED IN THE CEILING AT INTERSECTIONS OF CORRIDORS AND AT JUNCTIONS OF CORRIDORS WITH LOBBIES OR OTHER SIMILAR AREAS. • FOR CEILING AREAS EXCEEDING 2500 SQUARE FEET, A SEISMIC SEPARATION JOINT SHALL BE PROVIDED TO DIVIDE THE CEILING INTO AREAS NOT EXCEEDING 2500 SQ. FT. • PENETRATIONS THROUGH THE CEILING FOR SPRINKLER HEADS AND OTHER SIMILAR DEVICES THAT ARE NOT INTEGRALLY TIED TO THE CEILING SYSTEM IN THE LATERAL DIRECTION SHALL HAVE A TWO (2) INCH OVERSIZED RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FREE MOVEMENT OF ONE (1) INCH IN ALL HORIZONTAL DIRECTIONS. A FLEXIBLE SPRINKLER HOSE FITTING THAT CAN ACCOMMODATE ONE (1) INCH OF CEILING MOVEMENT SHALL BE PERMITTED TO BE USED IN LIEU OF THE OVERSIZED RING, SLEEVE OR ADAPTER. SUCH FLEXIBLE SPRINKLER HOSE SHALL BE ADEQUATELY SUPPORTED FROM SOFFIT SO AS NOT TO EXCEED THE MAXIMUM TRIBUTARY WEIGHT OF THE CEILING. 4. GYPSUM BOARD INSTALLATION SHALL COMPLY WITH ASTM C840-11: • GYPSUM BOARD SHALL CONSIST OF SINGLE-PLY ½” OR 5/8” THICK IN ACCORDANCE WITH ASTM C11-10a. • GYPSUM BOARD SHALL BE INSTALLED PERPENDICULAR TO FURRING WITH SCREWS AT 12" ON CENTER MAXIMUM, IN ACCORDANCE WITH ASTM C840-11. • GYPSUM BOARD SHALL BE ATTACHED TO FURRING/FRAMING WITH ASTM C1002-07 TYPE S (ASTM A568-11b GRADES 1018 TO 1022) SCREWS (NOT LESS THAN, N0. 6, WITH MAJOR DIAMETER NOT LESS THAN 0.136 IN). 15/A5-04 -/--- NOTE: SEE DETAILS 03 & 04/A5-02 FOR TOP OF SOFFIT CONNECTION (E) DRYWALL CEILING (N) ACOUSTICAL CEILING TILE (E) SUSPENDED CEILING SYSTEM NEW METAL STUD FRAMING (N) DRYWALL SOFFIT R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:23:14 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A5-04 DETAILS - TYPICAL CEILING CA361 1 1 - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 1/8" = 1'-0"ACT DIAGRAMATIC CEILING PLAN 02 N/AACT SUSPENDED CEILING NOTES 01 3" = 1'-0"ACT FIXTURE SUSPENSION 04 3" = 1'-0"ACT COMPRESSION STRUT 03 3" = 1'-0"CEILING WIRE AT PERIMETER OBSTRUCTION 06 3" = 1'-0"COMPRESSION STRUT ANCHORAGE 08 3" = 1'-0"SUSPENSION WIRE CONNECTION @ ROOF 07 3" = 1'-0"ACT PERIMETER ATTACHMENT 05 3" = 1'-0"GYP. BD. CEILING - SPLICE DETAILS 15 3" = 1'-0"GYP. BD. COMPRESSION STRUT 11 1/8" = 1'-0"GYP. BD. DIAGRAMATIC CEILING PLAN 10 3" = 1'-0"GYP. BD. FIXTURE SUSPENSION 12 3" = 1'-0"GYP. BD. PERIMETER ATTACHMENT 13 3" = 1'-0"GYP. BD. PERIMETER ATTACHMENT - FURRING 14 N/AGYP. BOARD SUSPENDED CEILING NOTES 093" = 1'-0"CEILING TRANSITION, GYP TO ACT 17 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 1 SINGLE FLUSH DOOR W H 3' - 2 " FOR PARTITION TYPES THROAT: SEE PLAN HEADER FRAMING PER 11/A5-02 FRAME ANCHOR - PROVIDE (1) FOR EVERY 24" OF JAMB LENGTH FASTEN FRAME TO JAMB FRAMING W/ (2) #10 SMS PER ANCHOR WELDED HOLLOW METAL FRAME PER DOOR SCHEDULE GYP. BD. WITH SCHEDULED FINISH, TYP. CONT. SEALANT AT EACH SIDE OF PARTITION INSULATION WHERE OCCURS -SEE PLANS FOR PARTITION TYPES HEADER FRAMING PER 11/A5-02 FASTEN FRAME TO JAMB FRAMING W/ (2) #10 SMS PER ANCHOR KNOCK DOWN METAL FRAME WITH MITRED CORNERS PER DOOR SCHEDULE GYP. BD. WITH SCHEDULED FINISH, TYP. CLIP ON TRIP PER MANUFACTURER INSULATION WHERE OCCURS -SEE PLANS FOR PARTITION TYPES FOR PARTITION TYPES THROAT: SEE PLANS FOR PARTITION TYPES THROAT: SEE PLAN (PER NFPA 80) 1/2" MIN. 4" TYPICAL DISTANCE FROM ADJACENT PARTITION WHERE OCCURS -SEE PLANS JAMB FRAMING PER 14/A5-02 FRAME ANCHOR - PROVIDE (1) FOR EVERY 24" OF JAMB LENGTH FASTEN FRAME TO JAMB FRAMING W/ (2) #10 SMS PER ANCHOR WELDED HOLLOW METAL FRAME PER DOOR SCHEDULE GYP. BD. WITH SCHEDULED FINISH, TYP. CONT. SEALANT AT EACH SIDE OF PARTITION INSULATION WHERE OCCURS -SEE PLANS FOR PARTITION TYPES NOTE: PROVIDE FLOOR ANCHORS FOR FRAMES PER MANUFACTURER'S RECOMMENDATIONS AND PER SPECIFICATIONS UNDERCUT 3/4" MAX. CENTER MATERIAL TRANSITION - WELDING ROD UNDER DOOR PANEL (E) FLOOR FINISH SCHEDULED FRAME SCHEDULED DOOR SCHEDULED FLOOR FINISH SCHED. PARTITION A WELDED STEEL 3 PIECE KNOCKDOWN FRAME WITH RETURNS FRAME TYPE: 1/2" 1/2"1 7/8" VARIES 1 7/8" SCHED. PARTITION 1/2" 1/2"1 7/8" VARIES 1 7/8" B WELDED STEEL 3 PIECE KNOCKDOWN FRAME WITH RETURNS AND LEAD-LINING FRAME TYPE: HW-1 (LEAD SHEILDED) QTY ITEM / FUNCTION MODEL FINISH MANUFACTURER 1 PASSAGE LOCKSET 9K30N15D-LL 626 BEST ACCESS 1 BOTTOM PIVOT L147-20 LESS TOP PIVOT 626 RIXSON 2 INTERMEDIATE PIVOT ML 19-20 626 RIXSON 3 SILENCERS SR644 BLK IVES 1 KICK PLATE K0038 630 TRIMCO 1 WALL STOP 1270CV 630 TRIMCO 1 CLOSER 8916-AF89-FC-SN2 689 DORMAKABA SEE PHYSICIST REPORT FOR SHIELDING REQUIREMENTS. HW-2 (DRESSING ROOM) QTY ITEM / FUNCTION MODEL FINISH MANUFACTURER 1 PASSAGE SET 9K30N15D 626 BEST ACCESS 3 HINGES BB1168 652 HAGER 1 OCCUPANCY INDICATOR B571 626 SHLAGE 1 KICK PLATE K0038 630 TRIMCO 1 OVERHEAD HOLDER-STOP #6ADJ 626 RIXSON 3 SILENCERS SR64 BLK IVES HW-3 (CARD READER) QTY ITEM / FUNCTION MODEL FINISH MANUFACTURER 2 HINGE BB1168 626 HAGGAR 1 ELECTRIC HINGE BB1168-ETW 626 HAGGAR 1 ELECTRIC LOCKSET 93K30N15D 626 BEST ACCESS 1 CLOSER 8916-AF89-FC-SN2 626 DORMAKABA 3 SILENCERS SR64 BLK IVES 1 CARD READER 1 REQUEST TO EXIT 1 DOOR POSITION SWITCH SEE SECURITY DRAWINGS, 11/T5-01 HW-4 (STOREROOM LOCK) QTY ITEM / FUNCTION MODEL FINISH MANUFACTURER (3) HINGES TA714 630 MCK (1) STOREROOM LOCK 45H7D 14H 630 BES (1)PERMANENT CORE 1CM7 626 BES (1) OVERHEAD HOLDER 2-SERIES 630 RIX (1) SET SEALS S44D MITRED DKB PEM A.HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL COMPLY WITH 11B-309.4 B.THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS 11B-404.2.9 1. INTERIOR HINGED DOORS AND GATES: 5 POUNDS MAXIMUM. 2. SLIDING OR FOLDING DOORS: 5 POUNDS MAXIMUM. 3. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS 4. EXTERIOR HINGED DOOR: 5 POUNDS MAXIMUM. C.SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16 INCH OF THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED. 11B-404.2.10 GENERAL NOTES - DOOR ACCESSIBILITY METAL STUD FRAMING. MODIFY AS NEEDED. (N) SILL FRAMING PER 06/A5-02 LEAD SHIELDING IN FRAME. (N) OBSERVATION WINDOW ASSEMBLY. LEAD GLASS, LEAD LINED HM FRAME. COMPLY WITH REQUIREMENTS NOTED IN PHYSICIST REPORT. SEE SHEET Q8-11. ENSURE CONTINUITY OF LEAD LINED SHIELDING PROTECTION. CONTROL ROOM SIDE RADIOLOGY ROOM SIDE RADIOLOGY ROOM SIDE CONTROL ROOM SIDE 2" STL. GLASS STOP W/ COUNTERSUNK METAL SCREWS (N) JAMB STUDS FASTEN FRAME TO STUDS W/ (2) #10 S.M.S. PER ANCHOR WELD ANCHORS TO FRAME FASTEN FRAME TO STUDS W/ #12 FLAT HEAD S.M.S. (N) HOLLOW METAL WINDOW FRAME, PROVIDE (3) ANCHORS PER JAMB (N) LEAD GLASS 2" SEALANT, BOTH SIDES VERIFY EXISTING THROAT: (N) LEAD SHIELDING IN WALL. EXTEND INTO FRAME (N) LEAD SHIELDING IN FRAME (N) PARTITION (N) OBSERVATION WINDOW ASSEMBLY. LEAD GLASS, LEAD LINED HM FRAME. COMPLY WITH REQUIREMENTS NOTED IN PHYSICIST REPORT. SEE SHEET Q8-11. ENSURE CONTINUITY OF LEAD LINED SHIELDING PROTECTION. FASTEN FRAME TO STUDS W/ (2) #10 S.M.S. PER ANCHOR LEAD SHIELDING IN FRAME. (N) HEADER PER 11/A5-02 (N) CONTINUOUS STUD TRACK ENTIRE LENGTH OF MODIFIED PARTIAL HEIGHT WALL 6" CONTROL ROOM SIDE RADIOLOGY ROOM SIDE OBSERVATION WINDOW ASSEMBLY. LEAD GLASS, LEAD LINED HM FRAME. COMPLY WITH REQUIREMENTS NOTED IN PHYSICIST REPORT. SEE SHEET Q8-11. ENSURE CONTINUITY OF LEAD LINED SHIELDING PROTECTION. FASTEN FRAME TO STUDS W/ (2) #10 S.M.S. PER ANCHOR LEAD SHIELDING IN FRAME. HEADER PER 19/A6-01 8". 42" . 34" . 4" 16 GA METAL STUD (400S162-54) @ 16" O.C. SILL FRAMING PER 17/A6-01 LEAD SHIELDING IN FRAME. CONTROL ROOM SIDE RADIOLOGY ROOM SIDE (N) FLOORING AND BASE CONT. 4" 16 GA METAL TRACK (400T162-54) 5/8" GYP. BD. 7'-0" . 5/8" LEAD-LINED GYP. BD. PER PHYSICIST REPORT CONT. 4" 16 GA METAL TRACK (400T162-54) 1 SINGLE FIXED WINDOW WINDOW TYPE LEGEND @ SILL 34" H W FOR PARTITION TYPES THROAT: SEE PLAN (PER NFPA 80) 1/2" MIN. 4" TYPICAL DISTANCE FROM ADJACENT PARTITION WHERE OCCURS -SEE PLANS JAMB FRAMING PER FRAME ANCHOR -PROVIDE (1) FOR EVERY 24" OF JAMB LENGTH FASTEN FRAME TO JAMB FRAMING W/ (2) #10 SMS PER ANCHOR WELDED HOLLOW METAL FRAME PER DOOR SCHEDULE GYP. BD. WITH SCHEDULED FINISH, TYP. CONT. SEALANT AT EACH SIDE OF PARTITION INSULATION WHERE OCCURS -SEE PLANS FOR PARTITION TYPES NOTE: PROVIDE FLOOR ANCHORS FOR FRAMES PER MANUFACTURER'S RECOMMENDATIONS AND PER SPECIFICATIONS 2" LEAD LINED DOOR LEAD SHIELDING IN FRAME LEAD SHIELDING IN WALL. EXTEND INTO FRAME. GEN RAD ROOM SIDE CORRIDOR SIDE 14 A5-02 FOR PARTITION TYPES THROAT: SEE PLAN HEADER FRAMING PER FRAME ANCHOR - PROVIDE (1) FOR EVERY 24" OF JAMB LENGTH FASTEN FRAME TO JAMB FRAMING W/ (2) #10 SMS PER ANCHOR WELDED HOLLOW METAL FRAME PER DOOR SCHEDULE GYP. BD. WITH SCHEDULED FINISH, TYP. CONT. SEALANT AT EACH SIDE OF PARTITION INSULATION WHERE OCCURS -SEE PLANS FOR PARTITION TYPES LEAD SHIELDING IN FRAME LEAD LINED DOOR GEN RAD ROOM SIDE CORRIDOR SIDE 11 A5-02 TYPICAL DISTANCE FROM ADJACENT PARTITION WHERE OCCURS -SEE PLANS JAMB FRAMING PER 14/A5-02 FASTEN FRAME TO JAMB FRAMING W/ #10 SMS @ 11" O.C., TYP BOTH FACES KNOCK DOWN METAL FRAME WITH MITRED CORNERS PER DOOR SCHEDULE GYP. BD. WITH SCHEDULED FINISH, TYP. INSULATION WHERE OCCURS -SEE PLANS FOR PARTITION TYPES 4" CLIP ON TRIP PER MANUFACTURER LEAD SHIELDING IN FRAME LEAD SHIELDING IN WALL. EXTEND INTO FRAME. R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:21:19 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) A6-01 SCHEDULE - DOOR CA361 1 - - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 DOOR SCHEDULE DOOR NO.ROOM NAME DOOR FRAME FIRE RATING HDW SET NO. VIEW PANEL COMMENTS SIZE TYPE MATERIAL FINISH TYPE MATERIAL FINISH DETAILS TYPE SIZE W H THK HEAD JAMB SILL W H THK 1504 HALLWAY 3' - 0" 7' - 0" 1 3/4" 1 SC/WD PT-1 A STEEL P-2 07/A6-01 09/A6-01 08/A6-01 - 3 - 0" 0" 0" 1505 SHELL SPACE 3' - 6" 7' - 0" 1 3/4" 1 SC/WD PT-1 A STEEL P-2 07/A6-01 09/A6-01 08/A6-01 - 4 - 0" 0" 0" 1506 IMAGING, GEN 3' - 6" 7' - 0" 1 3/4" 1 SC/WD PT-1 B STEEL P-2 27/A6-01 29/A6-01 28/A6-01 - 1 - 0" 0" 0" THIS DOOR IS LEAD-LINED. REFER TO SHEET Q8-11 FOR ADDITIONAL REQUIREMENTS. 1511 DRESSING BOOTH 3' - 0" 7' - 0" 1 3/4" 1 SC/WD PT-1 A STEEL P-2 07/A6-01 09/A6-01 08/A6-01 - 2 - 0" 0" 0" 1513 DRESSING BOOTH 3' - 0" 7' - 0" 1 3/4" 1 SC/WD PT-1 A STEEL P-2 07/A6-01 09/A6-01 08/A6-01 - 2 - 0" 0" 0" 3/8" = 1'-0"DOOR TYPE LEGEND 20 03DOOR HARDWARE 3" = 1'-0"TYPICAL DOOR HEAD - HOLLOW METAL 07 3" = 1'-0"TYPICAL DOOR HEAD - KNOCK DOWN 08 3" = 1'-0"TYPICAL DOOR JAMB - HOLLOW METAL 09 3" = 1'-0"TYPICAL DOOR THRESHOLD - SIMILAR MATERIALS 01 02FRAME TYPE LEGEND 3" = 1'-0"LEAD LINED WINDOW - SILL 17 3" = 1'-0"LEAD LINED HM WINDOW JAMB DETAIL 18 3" = 1'-0"LEAD LINED WINDOW - HEAD 19 3" = 1'-0"LEAD LINED WINDOW SECTION 21 GENERAL NOTES: 1. SEE FINISH SCHEDUEL ON SHEET I1-11 FOR FINISH DEFINITIONS. 2. SEE SPECIFICATIONS -DEVISION 13, AND PHYSICIST REPORT ON SHEET Q8-11 FOR ADDITIONAL INFORMATION. ABBREVIATIONS: AL: AD: CLR: FF: HM: KD: LL: TEMP.GL.: STL: ALUMINUM ANODIZED CLEAR FACTORY FINISH HOLLOW METAL KNOCK-DOWN FRAME LEAD LINED TEMPERED SAFETY GLASS LIGHT STEEL WINDOW SCHEDULE WINDOW NO.ROOM NAME FRAME GLAZING COMMENTSWIDTH HEIGHT TYPE MATERIAL FINISH HEAD DETAIL JAMB DETAIL SILL DETAIL FIRE RATING TYPE THK 1 IMAGING, GENERAL 3' - 0" 3' - 6" 1 HM PT-1 19/A6-01 18/A6-01 17/A6-01 NR LEADED 0' - 0 1/2" THIS WINDOW IS LEAD SHIELDED. REFER TO SHEET Q8-11 FOR ADDITIONAL REQUIREMENTS. 3" = 1'-0"LEAD LINED HM DOOR JAMB DETAIL 29 3" = 1'-0"LEAD LINED HM DOOR HEAD DETAIL 27 3" = 1'-0"TYPICAL DOOR JAMB - KNOCK DOWN 28 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 D D D D *NOTE: *IF THERE ARE NO LINES TO SHOW EXTENT OF FINISHES, THEN THE SYMBOL IN THE ROOM REFERS TO ALL THE SURFACES IN THAT ROOM P 1 CT 1 FLOOR MATERIAL CODE FLOOR FINISH TYPE WALL FINISH CODE WALL FINISH TYPE EXTENT OF WALL FINISH* FLOORING DIRECTION P 1 BASE MATERIAL CODE BASE FINISH TYPE WALL FINISH TAG* BASE FINISH TAG FLOOR FINISH TAG T 1 TRANSITION FINISH CODE TRANSITION FINISH TYPE TRANSITION FINISH TAG CORNER GUARD TAG CORNER GUARD TYPE WP-1 WP-2 WALL PROTECTION TAG WALL PROTECTION TYPE PRIVACY CURTAIN TAG PRIVACY CURTAIN TYPE PC-1 CODE PL-1 PLASTIC LAMINATES PLASTIC LAMINATE ARBORITE ESSENTIAL NORDIC WOOD W481 CW MEDIUM GLOSS DESCRIPTION LOCATION IGENL CODE SSM-1 09 4000 SOLID SURFACE MATERIALS DESCPRITION LOCATION IGENLDESCRIPTION: COLOR: FINISH: MANUFACTURER: DESCRIPTION: COLOR: THICKNESS: MANUFACTURER: CODE PT-1 09 9000 PAINT INTERIOR FINISH PAINT DUNN EDWARDS DET648 WHITE PICKET FENCE SEMI-GLOSS DESCPRITION LOCATION FIELD, DOOR FRAMES, & DOORS DESCRIPTION: COLOR: TYPE: MANUFACTURER: CODE 09 5000 CEILINGS DESCPRITION LOCATION CODE RB-1 09 6500 WALL BASE RUBBER WALL BASE TARKET | JOHNSONITE 29 MOON ROCK DESCPRITION LOCATION ALL AREASDESCRIPTION: COLOR: MANUFACTURER: CODE RT-1 09 6000 FLOORING RESILIENT FLOORING SHAW CONTRACT RAFFIA 96710 TILE DESCPRITION LOCATION HALLW 1504, DRSSB 1513, VESTI 1511, WORKSTATION 1514 DESCRIPTION: COLOR: STYLE: MANUFACTURER: CODE WP-1 10 2600 WALL PROTECTION PLASTIC CORNER GUARD CS GROUP 934 PEARL 2"X2", SEE ELEVATIONS FOR LENGTHS DESCPRITION LOCATION SEE PLANSDESCRIPTION: COLOR: STYLE: MANUFACTURER: CODE PC-1 PRIVACY CURTAINS PRIVACY CURTAIN ICP MEDICAL RR-6200 BP DESCPRITION LOCATION IGENLDESCRIPTION: COLOR & PATTERN: MANUFACTURER: ACT-1 IGENL, DRSSB HALLW 1504, VESTI, WORKSTATION DESCRIPTION: GRID: TILE: MANUFACTURER: SOLID SURFACE -COUNTERTOP CORIAN GLACIER WHITE 5/8" ACOUSTICAL CEILING TILE ARMSTRONG PRELUDE XL, 15/16", HEAVY DUTY ULTIMA HIGH NRC SQUARE EDGE LAY-IN (24"X24") RS-1 RESILIENT FLOORING NORA SYSTEMS 6505 SILK (WELD ROD TO MATCH) NORAPLAN SENTICA, 3.0 MM -ARTICLE 1701 ∼39.37" X 48”, HEAT WELD ALL SEAMS IGENL 1506DESCRIPTION: COLOR: STYLE: MANUFACTURER: RS-2 RESILIENT FLOORING NORA SYSTEMS 6521 SUNDAY PAPER (WELD ROD TO MATCH) NORAPLAN SENTICA, 3.0 MM -ARTICLE 1701 ∼39.37" X 48”, HEAT WELD ALL SEAMS IGENL 1506DESCRIPTION: COLOR: STYLE: MANUFACTURER: CODE ART-16 ART WORK CUSTOM ART DESIGNTEX S08 AIR EXPERIENCE DESCPRITION LOCATION IGENLDESCRIPTION: IMAGE: MANUFACTURER: TYPE: PL-2 PLASTIC LAMINATE ARBORITE ULTRA WHITE -S575 MEDIUM GLOSS IGENLDESCRIPTION: COLOR: FINISH: MANUFACTURER: 3.1 2.7 2.5 2.3 1.4 G H J K 1498 ALCOVE, TELEPHONE ATELE 1499 OFFICE, GENERAL OGENL 1501 LOBBY LOBBY EL01 ELEVATOR ELEVA 1528 STORAGE, EQUIPMENT, GENERAL SEQGN 1529 ENVIRONMENTAL SERVICES CLOSET EVSRM 1527 OFFICE, GENERAL OGENL 1535 STORAGE, SUPPLIES SSUPP 1509 STORAGE, GENERAL SGENL 1507 IMAGING, MAMMOGRAPHY IMAMO 1506 IMAGING, GEN IGENL 1513 ACCESSIBLE DRESSING BOOTH DRSSA 1502 CORRIDOR CORRD1514 TECH WORKSTATION WSGEN 1517 TOILET/LAV, GENERAL TLGEN1518 TOILET/LAV, GENERAL TLGEN 1505 SHELL SPACE SHELL 1617 OFFICE, PROVIDER OPROV 1602 HALLWAY HALLW 1536 VESTIBULE VESTI 1538 TOILET, PATIENT, SPECIMEN TLPTS 1534 LABORATORY LBTRY1537 TOILET, PATIENT, SPECIMEN TLPTS 1534B BLOOD DRAW STATION BLDDR 1701 WAITING AREA, GENERAL WTAGN 1507A ACCESSIBLE DRESSING BOOTH DRSSA WP-1 1507 IMAGING, MAMMOGRAPHY IMAMO 1511 DRESSING BOOTH DRSSB 1530 WORK AREA, GENERAL WAGEN RB 1 RS 1 PT 1 RS 2 ART-16 PL-1 SSM-1 RB 1 PT 1 RT 1 PC - 1 WP-1 WP-1 WP-1 PL-2 PL-2 T 11504A HALLWAY HALLW 1504B HALLWAY HALLW 1510 SUBWAIT ROOM 1508 HALLWAY HALLW 1' - 5 " 4' - 8 " 4' - 1"10' - 4" 18' - 6 1/4" 1. U.N.O., EXTEND FLOOR FINISHES UNDER WALL MOUNTED HANDWASHING SINK. 2. U.N.O., WRAP WALL BASE AROUND BASE CABINETS. 3. U.N.O., ALL CEILINGS ARE ACT-1 4. U.N.O., CONTRACTOR TO FIELD VERIFY ALL FINISHES NOTED AS MATCH EXISTING. 5. FOR ALL (E) DOORS IN HALLWAY, PAINT ONLY SIDE FACING HALLWAY. 6. FOR TRANSITION #1 REFER TO DETAIL 10/A6-01 GENERAL NOTES N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:22:29 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) I1-11 PLAN - FINISH 1ST FLR CA361 1 1 - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 SHEET KEYNOTES LEGEND NAINTERIOR FINISH LIST 04 1/4" = 1'-0"PLAN - FINISH 1ST FLR 01 N KEY PLAN CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 J 1 D D EPO ES ES D D CR CR EP O T LEGEND CHTK 800E-AA FURNITURE TAG - SEE FURNITURE SCHEDULE MODO 800E EQUIPMENT TAG - SEE EQUIPMENT SCHEDULE SPEC SPEC NO ( A SUFFIX OF "E" INDICATES EXISTING FURNITURE) SPEC SPEC NO ( A SUFFIX OF "E" INDICATES EXISTING EQUIPMENT) ACCESSORIES TAG - SEE ACCESSORIES SCHEDULE SPEC ( A SUFFIX OF "E" INDICATES EXISTING ACCESSORIES) MODO 800E 2.5 2.3 1.4 G H J K 2 1498 ALCOVE, TELEPHONE ATELE 1501 LOBBY LOBBY 1529 ENVIRONMENTAL SERVICES CLOSET EVSRM 1509 STORAGE, GENERAL SGENL 1507 IMAGING, MAMMOGRAPHY IMAMO 1506 IMAGING, GEN IGENL 1513 ACCESSIBLE DRESSING BOOTH DRSSA 1502 CORRIDOR CORRD 1514 TECH WORKSTATION WSGEN 1517 TOILET/LAV, GENERAL TLGEN1518 TOILET/LAV, GENERAL TLGEN 1505 SHELL SPACE SHELL 1617 OFFICE, PROVIDER OPROV 1602 HALLWAY HALLW 1701 WAITING AREA, GENERAL WTAGN 1507A ACCESSIBLE DRESSING BOOTH DRSSA RAUN 216-8 RAUN 216-5 RAUN 216-7 RAUN 216-6 HALI 209 STDO 274 STIV 216 TRCY 215 SHRA 204 STST 216 COSH 518 DIGL 211 RAUN 216-1 RAUN 216-13 CHSM 803 CHTK 802 TAAM 802 TEPH 200CHSM 803 CHSM 803 TAAM 800 CHTK 802 BACS 200 RAUN 216-11 DG SD PTD MR WR MR PUIN 242 COWA 202 PRIN 200 MOPE 800 RAUN 216-3 RAUN 216-2 BACS 200 TEPH 200 SCAN 200 SCAN 200 1510 SUBWAIT ROOM 1508 HALLWAY HALLW1504B HALLWAY HALLW 1511 DRESSING BOOTH DRSSB 1504A HALLWAY HALLW CHSM 803 RAAL 224 APLE 203 BOTR 203 BOBU 805 COTE 200 COTE 200 EGRK 801 EGRK 801 SFDP 802 SFDP 801 CH CH NOT APPLICABLE 1. U.N.O., CONTRACTOR TO COORDINATE INSTALLATION OF IMAGING EQUIPMENT WITH VENDOR. N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:22:20 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) Q1-11 PLAN - EQUIPMENT & FURNITURE CA361 1 1 - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 GENERAL NOTES SHEET KEYNOTES N 1/4" = 1'-0"PLAN - EQUIPMENT & FURNITURE 01 EQUIPMENT SCHEDULE SPEC SPEC NO.QTY DESCRIPTION MANUFACTURER MODEL # RESP. CODE MOUNTING DIMENSIONS (INCHES) WEIGHT (LBS.) UTILITIES BIOMED ANCHORAGE DETAIL #NOTESLE N G T H HE I G H T WI D T H ( D E P T H ) DI A . PLUMB.ME C H . EL E C T . DED. CKT.NEMA DATA APLE 203 1 APRON, LEAD, PATIENT PROTECTION INFAB CORPORATION 683400 BACS 200 2 BAR CODE SCANNER, GENERIC KP-IT KP-IT OFOI COUNTER <varies> <varies> <varies> <varies> No No <varies> No <varies> No N/A BOTR 203 1 PATIENT TRANSFER UNIT BOARD TBD TBD CH 2 COAT HOOK BOBRICK B-542 DOOR COSH 518 1 CONTAINER, SHARPS BD MEDICAL 305096 OFCI WALL 13.94 14.88 5.83 4 No No No No No No N/A COTE 200 2 NEW COMPUTER, KP IT KP IT COWA 202 1 CONTAINER, WASTE, BIOHAZARD RUBBERMAID FG614600 WHT FREE STANDING No No No No No No N/A DIGL 211 1 DISPENSER, GLOVE , THREE BOX BOWMAN MANUFACTURING COMPANY, INC GP-015 OFCI WALL 15.70 10.10 3.90 1 No No No No No No N/A EGRK 801 2 MONITOR ARM KP IT KP IT HALI 209 1 HAMPER STAND, WITH LID, HYDRAULIC PEDIGO PRODUCTS, INC P-1120-L-SS OFOI MOBILE 23.41 32.30 23.19 19 No No No No No N/A PRIN 200 1 PRINTER, GENERIC KP-IT KP-IT OFOI COUNTER No No Yes No Yes No N/A PUIN 242 1 INFUSION PUMP No No No No No No N/A RAAL 224 1 RACK, APRON, LEAD, 2 APRON, WITH GLOVES INFAB CORPORATION 683102 RAUN 216-1 1 CONTROL ROOM MODULE SIEMENS N/A OFVI COUNTER 4.75 3.19 10.06 2 No No No No N/A RAUN 216-2 1 IMAGING SYSTEM - KEYBOARD AND MOUSE SIEMENS N/A OFVI COUNTER No No No No N/A RAUN 216-3 1 COLOR CONTROL ROOM DISPLAY SIEMENS N/A OFVI COUNTER No No No No N/A RAUN 216-4 1 IMAGING SYSTEM CONTAINER (UNDER CONTROL ROOM TABLE) SIEMENS N/A OFVI FLOOR 13.44 21.75 25.94 116 No No Yes No N/A RAUN 216-5 1 YSIO MAX TABLE WITH MOBILE DETECTOR SIEMENS N/A OFVI FLOOR 31.50 37.56 94.81 835 No No Yes No 11/S5-01 RAUN 216-6 1 POLYDOROS R80 (80KW) GENERATOR CABINET SIEMENS N/A OFVI FLOOR 31.50 86.75 17.13 883 No No Yes Yes 16/S5-01 RAUN 216-7 1 ACCESS POINT (TOP OF GENERATOR) SIEMENS N/A OFVI COUNTER 7.81 6.25 2.88 5.5 No No No No N/A RAUN 216-8 1 YSIO MAX WALL STAND WITH FIXED DETECTOR (LEFT LOADING GRID) SIEMENS N/A FLOOR 30.00 85.00 49.00 661 21//S5-01 RAUN 216-9 1 CEILING RAILS FOR X-RAY TUBE SUSPENSION SIEMENS N/A RAUN 216-10 1 FULLY AUTOMATED BRIDGE AND X-RAY TUBE STAND SIEMENS N/A RAUN 216-11 1 GRID HOLDER (WALL MOUNTED) SIEMENS N/A WALL 21.69 16.56 4.00 22 02/S5-02 RAUN 216-13 1 REMOTE CONTROL CHARGING STATION SIEMENS N/A OFVI COUNTER 17.38 27.00 32.50 No No No No N/A SCAN 200 2 SCANNER, DOCUMENT, GENERIC INFORMATION AND TECHNOLOGY SERVICES - SHRA 204 1 SHIELD, RADIATION, JUMBO FLUKE BIOMEDICAL RADIATION MANAGEMENT SERVICES 56-604 OFOI MOBILE 30.00 75.00 24.00 113 No No No No N/A STDO 274 1 STOOL, ADJUSTABLE, WITHOUT BACK MIDMARK CORP 272-002-866 OFOI MOBILE 24.50 15 No No No No N/A STIV 216 1 INTRAVENOUS POLE PEDIGO PRODUCTS, INC. P-1080-6 MOBILE N/A STST 216 1 STOOL, STEP, HANDRAIL PEDIGO PRODUCTS, INC P-10-A-K OFOI FREE STANDING 16.00 38.50 12.00 21 No No No No N/A TEPH 200 2 TELEPHONE KP-IT KP-IT COUNTER No No Yes Yes N/A TRCY 215 1 CYLINDER TRUCK Yes Yes Yes No N/A ACCESSORIES SCHEDULE SPEC QTY DESCRIPTION MANUFACTURER MODEL # RESP. CODE MOUNTING DIMENSIONS (INCHES) WEIGHT (LBS.) ANCHORAGE DETAIL #NOTESLE N G T H HE I G H T WI D T H ( D E P T H ) DI A . CH 2 COAT HOOK BOBRICK B-542 DOOR DG 1 DEGERMER ECOLAB 92021193 CFCI WALL 11.10 6.12 3.97 N/A MR 2 FULL LENGTH MIRROR BOBRICK B-165 SERIES CFCI WALL 24.00 60.00 10/A5-02 PTD 1 PAPER TOWEL DISPENSER BOBRICK B-2621 CFCI WALL 10.81 14.06 3.94 N/A SD 1 SOAP DISPENSER ECOLAB 92021121 CFCI WALL N/A WR 1 WASTE RECEPTACLE BOBRICK 367-60 OFOI FREE STANDING N/A FURNITURE SCHEDULE SPEC SPEC NO. QTY DESCRIPTION MANUFACTURER MODEL # RESP. CODE MOUNTING EL E C T . ANCHORAGE DETAIL #NOTES BOBU 805 1 BOARD, BULLETIN 36"X48" TBD TBD OFVI WALL 10/A5-02 CHSM 803 3 CHAIR, SIDE, METAL HERMAN MILLER VERUS BARIATRIC CHAIR OFVI MOBILE No N/A CHTK 802 2 CHAIR, TASK HERMAN MILLER VERUS OFVI MOBILE No N/A MOPE 800 1 MOBILE PEDESTAL BOX FILE KAISER VERNON KAISER VERNON CFCI MOBILE No N/A LENGTH: 18", HEIGHT: 21", DEPTH: 23" SFDP 801 2 SYSTEMS FURNITURE, DEMOUNTABLE PARTITIONS HERMAN MILLER VFVI FLOOR N/A SFDP 802 1 SYSTEMS FURNITURE, DEMOUNTABLE PARTITIONS HERMAN MILLER VFVI FLOOR N/A TAAM 800 1 TABLE, ADJUSTABLE, MOTORIZED KAISER VERNON KAISER VERNON OFCI FREE STANDING Yes N/A SEE SHEET A5-03 FOR ADDITIONAL INFORMATION TAAM 802 1 TABLE, CUSTOM MOTORIZED ADJUSTABLE KAISER VERNON KAISER VERNON OFCI FREE STANDING Yes N/A SEE SHEET A5-03 FOR ADDITIONAL INFORMATION KEY PLAN CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 7/3/2024 8:09:08 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) Q7-01 IMAGING EQUIPMENT VENDOR DRAWINGS RM 1507 (FOR REFERENCE ONLY) CA361 1 1 - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 PLAN CHECK CORRECTIONS 07/02/2024 1900 E 4th St - 1011190678/9/2024 R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 7/3/2024 8:09:13 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) Q7-02 IMAGING EQUIPMENT VENDOR DRAWINGS RM 1507 (FOR REFERENCE ONLY) CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 PLAN CHECK CORRECTIONS 07/02/2024 1900 E 4th St - 1011190678/9/2024 R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 7/3/2024 8:09:33 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) Q7-03 IMAGING EQUIPMENT VENDOR DRAWINGS RM 1507 (FOR REFERENCE ONLY) CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 PLAN CHECK CORRECTIONS 07/02/2024 1900 E 4th St - 1011190678/9/2024 R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 7/3/2024 8:09:38 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) Q7-04 IMAGING EQUIPMENT VENDOR DRAWINGS RM 1507 (FOR REFERENCE ONLY) CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 PLAN CHECK CORRECTIONS 07/02/2024 1900 E 4th St - 1011190678/9/2024 R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 7/3/2024 8:09:44 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) Q7-05 IMAGING EQUIPMENT VENDOR DRAWINGS RM 1507 (FOR REFERENCE ONLY) CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 PLAN CHECK CORRECTIONS 07/02/2024 1900 E 4th St - 1011190678/9/2024 D D D D CR CR RE X T 3.1 2.7 2.5 2.3 1.4 3 G H J K 2 1507 IMAGING, MAMMOGRAPHY1505 SHELL SPACE 1617 OFFICE, PROVIDER 1507A ACCESSIBLE DRESSING BOOTH 1509 STORAGE, GENERAL 1529 ENVIRONMENTAL SERVICES CLOSET 1501 LOBBY 1498 ALCOVE, TELEPHONE 1499 OFFICE, GENERAL 1502 CORRIDOR 1513 ACCESSIBLE DRESSING BOOTH EL01 ELEVATOR 1528 STORAGE, EQUIPMENT, GENERAL 1527 OFFICE, GENERAL 1535 STORAGE, SUPPLIES 1514 TECH WORKSTATION1517 TOILET/LAV, GENERAL 1518 TOILET/LAV, GENERAL 1536 VESTIBULE 1538 TOILET, PATIENT, SPECIMEN 1534 LABORATORY 1537 TOILET, PATIENT, SPECIMEN 1701 WAITING AREA, GENERAL A B E D C 1504A HALLWAY 1511 DRESSING BOOTH 1504B HALLWAY 1510 SUBWAIT ROOM 1508 HALLWAY 1506 IMAGING, GEN 1506A CONTROL ROOM 1. REFER TO PHYSICIST REPORT DATE D 03/01/2024 FOR ADDITIONAL INFORMATION 2. U.N.O., ALL PORTIONS OF DESIGNATED RADIATION BARRIER (I.E. DOORS, WINDOWS, ETC.) ARE TO HAVE THE SAME ATTENUATION CHARACTERISTICS AS STIPULATED FOR THAT GIVEN BARRIER. N PARTITION W/ LEAD SHIELDING R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/25 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:23:01 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) Q8-11 PLAN - SHIELDING RM 1507 CA361 1 1 - CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 GENERAL NOTES LEGEND N 1/4" = 1'-0"PLAN - PHYSICIST REPORT 01 KEY PLAN LEAD SHIELDING SCHEDULE 0212" = 1'-0"PHYSICIST REPORT BARRIER LEAD SHIELDING NOTES FLOOR NO ADDITIONAL SHIELDING REQ.- A 2.0 LBS PER SF LEAD (1/32" THICK)THE OBSERVATION WINDOW IN BARRIER A REQUIRES 2.0 LB/SQ. FT LEADED GLASS. NOBODY SHOULD STAND IN THE OPEN AREA DURING X-RAY EXPOSURE. B 2.0 LBS PER SF LEAD (1/32" THICK)- D 6.0 LBS PER SF LEAD (3/32" THICK)- C 2.0 LBS PER SF LEAD (1/32" THICK)THE DOOR LOCATED IN BARRIER C MUST BE LINED WITH 2.0 LB/SQ.FT LEAD (1/32" THICK) E 2.0 LBS PER SF LEAD (1/32" THICK)- CEILING 2.0 LBS PER SF LEAD (1/32" THICK)- CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 J 1 D D PS EPO ESES PS PS D D EP O PS T 2.7 2.5 2.3 1.4 F G H J K 1501 LOBBY LOBBY 1529 ENVIRONMENTAL SERVICES CLOSET EVSRM 1509 STORAGE, GENERAL SGENL 1507 IMAGING, MAMMOGRAPHY IMAMO 1506 IMAGING, GEN IGENL 1513 ACCESSIBLE DRESSING BOOTH DRSSA 1502 CORRIDOR CORRD 1517 TOILET/LAV, GENERAL TLGEN 1518 TOILET/LAV, GENERAL TLGEN 1505 SHELL SPACE SHELL 1504A VESTIBULE VESTI 1617 OFFICE, PROVIDER OPROV 1602 HALLWAY HALLW 1701 WAITING AREA, GENERAL WTAGN 1507A ACCESSIBLE DRESSING BOOTH DRSSA 30"X36" CLR 1506A CONTROL ROOM CRRAD 1514 TECH WORKSTATION WSGEN 1504B HALLWAY HALLW 15 0 5 1504 15 0 6 15 1 1 1511 DRESSING BOOTH DRSSB 15 1 3 1505-01 1517-01 1506-01 1512-01 1511-01 1517-02 1511-03 1511-02 1512-02 1504-01 1512-03 1511-04 1506-021517-03 1504A-01 1504-04 1504-02 1504-03 1510 SUBWAIT ROOM 1508 HALLWAY HALLW 12 / A 2 -03 1513-01 1506-03 SIGN TAG - SEE SIGNAGE SCHEDULE11C32-02 N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/24 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO.ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. KEY PLAN https://my.matterport.com/show/?m=FW21iEbmuiiC:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:24:04 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) SG1-11 SIGNAGE - PLAN CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 1/4" = 1'-0"PLAN - REMODEL 1ST FLR SIGNAGE 01 GENERAL NOTES 1. CONTRACTOR TO CONFIRM REQUIRED NEW SIGNAGE NAME AND NUMBER WITH OWNER BEFORE MANUFACTURING. LEGEND SIGN TYPE SCHEDULE SIGN TYPE DESCRIPTION COMMENTS 1504-01 DIR286 - 12"X12" DIRECTIONAL SIGN SEE 10/SG5-01 FOR DETAILS 1504-02 REG548 - 12"X12" REGULATORY SIGN SEE 05/SG5-01 FOR DETAILS 1504-03 REG548 - 12"X12" REGULATORY SIGN SEE 05/SG5-01 FOR DETAILS 1504-04 DIR286 - 12"X12" DIRECTIONAL SIGN SEE 10/SG5-01 FOR DETAILS 1504A-01 DIR286 - 12"X12" DIRECTIONAL SIGN SEE 10/SG5-01 FOR DETAILS 1505-01 ID312 - 6"X6" ROOM IDENTIFICATION SEE 03/SG5-01 FOR DETAILS 1506-01 ID312 - 6"X6" ROOM IDENTIFICATION SEE 03/SG5-01 FOR DETAILS 1506-02 REG506 - 6"X6" REGULATORY SIGN SEE 01/A2-02 FOR DETAILS 1506-03 REG544.1 - 9"X9" INFORMATION SIGN SEE 13/A2-01 FOR DETAILS 1511-01 ID312 - 6"X6" ROOM IDENTIFICATION SEE 03/SG5-01 FOR DETAILS 1511-02 6"X6" REGULATORY SIGN SEE 04/A2-03 FOR DETAILS 1511-03 INFO407 9"X9" INFORMATION SIGN SEE 04/A2-03 FOR DETAILS 1511-04 INFO407 9"X9" INFORMATION SIGN SEE 04/A2-03 FOR DETAILS 1512-01 ID312 - 6"X6" ROOM IDENTIFICATION SEE 03/SG5-01 FOR DETAILS 1512-02 INFO407 - 9"X9" INFORMATION SIGN SEE 09/A2-03 FOR DETAILS 1512-03 INFO407 - 9"X9" INFORMATION SIGN SEE 09/A2-03 FOR DETAILS 1513-01 ID312 - 6"X6" ROOM IDENTIFICATION SEE 03/SG5-01 FOR DETAILS 1517-01 ID332.12 - 9"X9" REGULATORY SIGN SEE 08/SG5-01 FOR DETAILS 1517-02 ID378 - 12" DIA. REGULATORY SIGN SEE 11/SG5-01 FOR DETAILS 1517-03 ID325.3 - 8.5"X8.5" BUILDING AMENITIES SIGN SEE 09/SG5-01 FOR DETAILS CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 B TYPICAL MOUNTING SIGN NEXT TO AN OUT SWINGING DOOR, U.N.O. TYPICAL MOUNTING SIGN NEXT TO AN IN SWINGING DOOR, U.N.O. A 9" TO TOP OF SIGN 61 " 9" TO T O P O F S I G N 61 " MOUNTING SURFACE SIGN IS 1/8" THICK ACRYLIC WITH SPRAY PAINTED FACE AND EDGES; FACE HAS DIGITALLY PRINTED COPY SIGN PANEL IS MOUNTED TO SURFACE WITH 1/16" THICK VHB TAPE RAISED COPY RAISED BRAILLE SIGN PANEL AND EDGES ARE SPRAY PAINTED; FACE HAS SURFACE APPLIED PAINTED ADA COMPLIANT RAISED COPY & GRADE2 TRANSLATION BRAILLE, ALL PANEL EDGES ARE FINISHED AND FLUSHED MOUNTING SURFACE SIGN PANEL IS MOUNTED TO SURFACE WITH 1/16" THICK VHB TAPE GEN RAD ID314-5/8”CAP HEIGHT TYPE COLOR: GRAY 38 BACKGROUND COLOR: WHITE 37 MOUNTING: TYPE B 6" 6" NOTE: SEE ROOM NUMBER ON PLANS FOR "X" NUMBER DESIGNATOR. NAME ON THIS DETAIL IS FOR REFERENCE ONLY. CONFIRM NAME AND NUMBER WITH OWNER. SEE SIGNAGE PLAN FOR PLACEMENT. X 6" 6" 60 " A F F M A X SIGN ON DOOR 1/4" THICK SIGN WITH 1/8" RADIUS CORNERS ON 1/4" THICK EQUILATERAL TRIANGLE SIGN ON DOOR 1/4" THICK SIGN WITH 1/8" RADIUS CORNERS ON 1/4" THICK EQUILATERAL TRIANGLE ALL GENDER SIGN ON WALL ADJACENT TO DOOR 9" 9" RAISED TEXT W/ CONTRACTED GRADE 2 BRAILLE RAISED PICTOGRAMS WITHIN A MINIMUM 6" HIGH FIELD LO W E S T T A C T I L E C H A R A C TE R 48 " ELEVATION PLAN 18" 18 " EQ EQ CLEAR FLOOR SPACE 60 " EQ EQ 4" TO T O P O F S I G N 61 " M A X CH A R A C TE R Z O N E TA C T I L E NOTES: SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18" X 18" MIN, CENTERED ON THE TACTILE LETTERS IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. SINGLE DOOR: POSITION SIGN ALONGSIDE THE DOOR AT THE LATCH SIDE. DOUBLE DOOR: POSITION SIGN ON THE INACTIVE LEAF. IF TWO ACTIVE LEAVES, SIGN GOES TO RIGHT OF RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT SIDE OF DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. HI G H E S T T A C T I L E C H A R A C TE R 60 " 8 1/2" 8 1 / 2 " ID325.3 TYPE COLOR: GRAY 38 BACKGROUND COLOR: WHITE 37 MOUNTING: TYPE K (SIMILAR) 60 " O N C E N T E R TO T O P O F S I G N 61 " 3" 3" TO B O T T OM O F S I G N 7' - 0 " M A X . 1' - 0 " EXIT ROUTE NOTE: 1. CHARACTER AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. 2. CHARACTERS SHALL CONSTRAST WITH THEIR BACKGROUND. 3. BACKGROUND SHALL CONTRAST WITH THE WALL. 4. USE TYPEFACE FUTURA MEDIUM 5. ALL CHARACTER SHALL BE UPPERCASE 6. REFER TO CBC 11B-703.3 FOR BRAILLE REQUIREMENTS CONTRACTED (GRADE 2) BRAILLE -RAISED 1/40" 1-1/4" CAP HEIGHT - RAISED 1/32" 1/ 2 " M A X . 3/ 8 " M I N . 1" 1'-0" REG548 -1-1/4" CAP HEIGHT TYPE COLOR: GRAY 38 BACKGROUND COLOR: WHITE 37 CORNERS: RADIUS MOUNTING: TYPE B MAMMOGRAPHY 12" 12 " DIR286 TYPE COLOR: GRAY 38 BACKGROUND COLOR: WHITE 39 METAL FINISHES: BRUSHED ALUMINUM FONTS: FUTURA MEDIUM, FUTURA BOLD CONDENSED MOUNTING: REFER TO DIR-OP CONFIRM NAME WITH OWNER R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/24 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO. ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. https://my.matterport.com/show/?m=FW21iEbmuiiC: \ U s e r s \ jp a r k \ D o c u m e n t s \ R 3 14 4 1 2 . 4 4 - K P S A N 1s t F l r G e n R a d _ A 2 2_ C e n t r a l _ j h a L W M Q W. r v t 5/ 2 0 / 2 0 2 4 1 0 : 2 3 : 5 5 A M SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) SG5-01 DETAILS - SIGNAGE CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 NTSTYPICAL SIGNAGE MOUNTING HEIGHTS 01 NTSMOUNTING METHOD A 02NTSMOUNTING METHOD B 07 NTSID312 - ROOM IDENTIFICATION 03 NTSADA SIGN 04 NTSID378 - RESTROOM DOOR SIGNAGE 11 NTSID332.12 - RESTROOM DOOR SIGNAGE 08 3/8" = 1'-0"ELEVATION - RESTROOM 12 NTSID325.3 - BUILDING AMENITIES SIGNANGE 09 NTSELEVATION - RESTROOM 13 NTSREG548 - TACTILE EXIT ROUTE SIGN 05NTSDIR286 - DIRECTIONAL SIGN 10 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 E A S T F O U R T H S T R E E T CR CR T CR 10 9 8 7 6 5 4 1 3 L M N P QABCDEFGHJK 2 1108 TRASH1105 SLINC 1014 OPROV 1013 WSGEN 1012 EXROM1011 OPROV 1104 HALLW1015 EXROM1017 WSGEN 1310W01 WSGEN 1018 WSGEN 1010 EXROM 1009 EXROM 1150 HALLW 1109 EQRTR1107A SGENL 1103 SEQGN 1102 WRGEN 1016 EXROM1019 EXROM 1008 EXROM 1154A SCLOS 1101 CORRD1020 TLSTF 1007 EXROM 1153A VESTI 1153 SGENL 1154 TLPUB 1155 TLPUB 1150B ADRFT 1021 TLPAT1033 EQELC 1030 HALLW 1211 CONFR 1213 UTILC 1214 EXROM 1224 TLSTF 1215 AMENR 1024 UTILC 1022 PRMIN 1023 UTILS1006 OPROV 1005 EXROM 1209 HALLW 1025 AMENR 1029 HALLW1004 EXROM 1203 OPROV1217 WACPF 1216 OGENL 1223 EXROM 1026 AAMEN1003 WACPF 1204 OPROV 1217W01 WSGEN 1217W02 WSGEN 1217W03 WSGEN 1217W04 WSGEN 1217W05 WSGEN 1217W06 WSGEN 1210 HALLW 1027 WSGEN1002 OGENL 1028 WSGEN 1200 WTAGN1222 EXROM1221 EXROM 1220 EXROM 1218 UTILS 1300 CORRD 1001 WTAGN 1219 MEDPR 1201 RECEP 1212 HALLW 1206 EXROM1207 EXROM 1208 EXROM 1202 SGENL 1312 WAGEN 1312W01 WSGEN 1301 WTAGN1302 RECEP 1311B WACPF 1311A WACPF 1311 HALLW 1316 WTAGN1310 RECEP 1315 OGENL 1314 OGENL 1313 OGENL 102 WSGEN 1406 SMEDS 1408 OGENL 1407 OGENL 1409 EQMEC 1410 EQELV 1405 SGENL 1500 COORD 1404 TLSTF 1403 WADIS 1401 WTAGN 1402 CONSR 1205 OPROV 1031 HALLW 1411 EQMEC 1498 ATELE 1499 OGENL 1501 LOBBY EL01 ELEVA 1528 SEQGN 1529 EVSRM 1527 OGENL 1535 SSUPP 1509 SGENL 1507 IMAMO 1513 DRSSA 1502 CORRD 1514 WSGEN1517 TLGEN 1518 TLGEN 1505 SHELL 1504A VESTI 1617 OPROV 1616 EXROM 1620 WSGEN 1621 WSGEN 1622 TLPUB 1623 WSGEN 1624 AGENL 1625 EXROM 1630 EXROM 1626 EXROM 1627 EXROM 1628 OGENL 1629 TLGEN 1615 EXROM 1614 EXROM 1613 OPROV1612 EXROM 1611 EXROM1610 OPROV 1609 OPROV 1608 UTILC 1608A WSGEN 1602 HALLW 1605 EXROM 1606 EXROM 1607 EXROM 1808 TLPUB 1809 CORRD 1810 SGENL 1807 SGENL 1805 CONFR 1800A CORRD 1800 CORRD 1804 LNGST 1802 KITCH 1801 EVSRM 1800C VESTI 1706 EXROM 1707 EXROM 1708 UTILS 1704 HALLW 1704A UTILG 1726 OPROV 1711 EXROM 1709 PRMIN 1601 HALLW 1600 HALLW 1710 OGENL 1712 EXROM 1713 WSGEN 1714 WSGEN 1715 WRGEN 1716 TLPUB 1717 WSGEN 1718 WSGEN 1725 EXROM 1724 OPROV 1723 EXROM 1722 OPROV 1721 EXROM 1720 OPROV 1719 EXROM 1531 LNGST 1530 WAGEN 1532 OBSRM 1536 VESTI 1538 TLPTS 1534 LBTRY 1537 TLPTS 1534B BLDDR 1534C BLDDR 1534D BLDDR 1701 WTAGN 1702 RECEP 1703 WTAGN 1604 WTAGN 1800B VESTI 1803 TLPUB 1705 HALLW 1507A DRSSA 1506 IGENL 1511 DRSSB 1504 1504B HALLW 1 10 0 1 A DOOR/OPENING IDENTIFICATION SEE SECURITY SINGLE LINE ON PROXIMITY CARD READER ARROW INDICATES DIRECTION OF FREE MOVEMENT, DOOR IS CONTROLLED IN THE OPPOSITE DIRECTION. N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/24 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO.ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. KEY PLAN https://my.matterport.com/show/?m=FW21iEbmuiiC:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:23:50 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) T1-11 PLAN - REMODEL 1ST FLR - SECURITY CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 1/16" = 1'-0"PLAN - REMODEL OVERALL 1ST FLOOR - SECURITY 01 GENERAL NOTES SHEET KEYNOTES LEGEND N 1. ALL DEVICES AND CABINETS ON THIS FLOOR ARE EXISTING. NO NEW SCOPE UON. 2. THERE ARE NO NEW ELECTROMAGNETICALLY LOCKED EGRESS DOORS IN THIS PROJECT. ALL DOORS IN THIS PROJECT UON ARE COMPLIANT WITH CBC 1010.1.9.8 AND PROVIDE FREE EGRESS IN THE EXIT DIRECTION WITHOUT SPECIAL KNOWLEDGE, EFFORT OR USE OF A KEY. DOORS ARE NEVER LOCKED IN THE EXIT DIRECTION AT ANY TIME OR IN ANY CONDITION UON ON THE PLANS. 3. SECURITY CONTRACTOR SHALL PROVIDE AND INSTALL ALL WIRING, DEVICES, CONNECTIONS, PROGRAMMING, AND COORDINATION REQUIRED FOR A COMPLETELY FUNCTIONAL AND OPERATIONAL SYSTEM. SECURITY CONTRACTOR SHALL PROVIDE ANY CUSTOM BACKBOXES REQUIRED. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONDUIT, BACK BOXES, PULL POWER BOXES AS SHOWN ON DRAWINGS. 5. HARDWARE CONTRACTOR SHALL PROVIDE AND INSTALL ELECTRIFIED HARDWARE, ELECTRIC TRANSFER HINGES AND POWER BOOSTERS FOR PANIC HARDWARE AS REQUIRED. COORDINATE WITH THE SECURITY CONTRACTOR TO CONNECT THE HARDWARE TO THE SECURITY SYSTEM. CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1 PROVIDE MAKE READY J-BOX FOR FUTURE CARD READER. SEE 11/T5-01 FOR REQUIRED CONDUITS FOR FUTURE; 1) CARD READER J-BOX; 2) MAGNETIC DOOR ALARM CONTACT; 3) REX; 4) ELECTRIC TRANSFER HINGE. 1900 E 4th St - 1011190678/9/2024 MD MD TC CR CR CR CR CR CR CR CR CR CRCR CRCR CR CR CR CR CR PP AR M HB AR M HB HB HB HB MD CR ARM CR ACPACPACPIA P BM S BMS HB HB AR M AR M MD MD CR SM 10 9 8 7 6 5 4 1 3 L M N P QABCDEFGHJK 22323 CONFR 2320 OGENL 2321 WRGEN 2322 AGENL 2324 EVSRM 2300 CORRD DU10 MSHFT DU07 MSHFT 2023 PRGEN 2003 UTILC 2024 EXROM 2025 EXROM 2026 EXROM 2004 OGENL 2005 OGENL 2006 OGENL 2007 OGENL 2008 OGENL 2009 OGENL 2010 OGENL 2001-W1 WSGEN 2001-W2 WSGEN 2002 RECEP 2001A HALLW 2001C HALLW 2001B HALLW 2022 WSGEN 2021 WSGEN 2020 WTAGN 2032 HALLW 2031 HALLW 2028 SMEDS 2029 SGENL 2012 CORRD 2232 OGENL 2233 OEXPO 2234 OEXPO 2235 OEXPO 2236 OEXPO 2238 OEXPO 2239 OEXPO 2240 OEXPO 2241 OEXPO 2242 OEXPO 2243 OEXPO 2244 OEXPO 2245 OEXPO 2246 OEXPO 2247 OEXPO 2248 LNGST 2222 OEXPO 2223 OEXPO 2224 OGENL 2226 OGENL 2227 OEXPO 2228 OEXPO 2230 OEXPO 2231 OEXPO 2267 OEXPO 2266 OEXPO 2265 OEXPO 2264 OEXPO 2263 OEXPO 2262 OEXPO 2258 OEXPO-SHR 2257 OEXPO 2256 OEXPO 2255 OEXPO 2254 OEXPO 2261 HALLW 2271 GROUP 2273 OEXPO 2260 GROUP 2250 OEXPO 2251 GROUP 2270 OEXPO 2215 GROUP 2214 GROUP 2213 WRGEN 2211 TLPAT 2210 TLPAT 2209 TLPAT 2259 TLPAT 2208 HALLW 2249 SGENL 2220 WSGEN 2219 WACPF 2218 WTAGN 2217 RECEP 2217A RECEP 2216 OEXPO 2216A WARNS 2272 WTAGN 2403 EXROM 2404 EXROM 2405 OGENL 1 OPROV 2407 EXROM 2408 OPROV 2409 SGENL 2410 OPROV 2411 EXROM 2412 OPROV 2413 OGENL 2414 EXROM 2415 EXROM 2307 OPROV 2308 EXROM 2417 WSGEN 2416 WSGEN 2418 EXROM 2419 EXROM 2421 TLPAT 2420 PRMIN 2422 EXROM 2423 EXROM 2425 WSGEN 2424 WSGEN 2309 OGENL 2310 OPROV 2311 OGENL 2510 WSGEN 2511 EXROM 2512 EXROM 2513 WSGEN 2509 SGENL 2508 SGENL 2603 UTILS 2607 TLPAT 2609 UTILC 2507 DRSBB2506 LKRST 2505 WSGEN 2504 EXROM 2610 EXROM 2502 WSGEN 2503 OPROV 2611 OGENL 2612 EXROM 2615 WSGEN 2312 EXROM 2313 EXROM 2314 OPROV 2315 OPROV 2316 EXROM 2317 OGENL 2305 WSGEN 2304 EXROM 2303 EXROM 2302 WSGEN 2329 WSGEN 2330 EXROM 2 EXROM 2332 WSGEN 2606 SCREN 2605 TRNUR 2604 TRNUR 2328 LNGST 2327 EXROM 2600 WTAGN 2636 TLPAT 2632 WSGEN 2635 EQRTR 2631 WRDRP 2630 OGENL 2634 EXROM 2633 EXROM 2614 OEXPO 3 WSGEN 2616 OPROV 2617 OGENL 2325 PRMIN 2326 TLPAT 2318 EXROM 2319 OGENL 2625 EQRTR 2624 TLPAT 2629 UTILS 2622 EXROM 2623 EXROM 2618 WSGEN 2619 EXROM 2620 EXROM 2621 OPROV 2340 HALLW 2626 HALLW 2104 HALLW 2108 WRGEN 2027 OGEN2 2030 TLGEN 2013 HALLW 2014 HALLW 2201A EQMEC 2015 EVSCL 2101 EVSCL DU26 TLPUB DU27 TLPUB 2016 HALLW 2017 HALLW 2018 HALLW 2019 HALLW 2034 2035 2036 2037 1 AREA OF WORK LEGEND N R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/24 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO.ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. KEY PLAN https://my.matterport.com/show/?m=FW21iEbmuiiC:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:24:15 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) T1-21 PLAN - 2ND FLR - SECURITY CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 GENERAL NOTES SHEET KEYNOTES 1/16" = 1'-0"PLAN - REMODEL OVERALL 2ND FLOOR - SECURITY 01 1 (E) ACP PANEL 1. ALL DEVICES AND CABINETS ON THIS FLOOR ARE EXISTING. NO NEW SCOPE UON. 2. THERE ARE NO NEW ELECTROMAGNETICALLY LOCKED EGRESS DOORS IN THIS PROJECT. ALL DOORS IN THIS PROJECT UON ARE COMPLIANT WITH CBC 1010.1.9.8 AND PROVIDE FREE EGRESS IN THE EXIT DIRECTION WITHOUT SPECIAL KNOWLEDGE, EFFORT OR USE OF A KEY. DOORS ARE NEVER LOCKED IN THE EXIT DIRECTION AT ANY TIME OR IN ANY CONDITION UON ON THE PLANS. 3. SECURITY CONTRACTOR SHALL PROVIDE AND INSTALL ALL WIRING, DEVICES, CONNECTIONS, PROGRAMMING, AND COORDINATION REQUIRED FOR A COMPLETELY FUNCTIONAL AND OPERATIONAL SYSTEM. SECURITY CONTRACTOR SHALL PROVIDE ANY CUSTOM BACKBOXES REQUIRED. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONDUIT, BACK BOXES, PULL POWER BOXES AS SHOWN ON DRAWINGS. 5. HARDWARE CONTRACTOR SHALL PROVIDE AND INSTALL ELECTRIFIED HARDWARE, ELECTRIC TRANSFER HINGES AND POWER BOOSTERS FOR PANIC HARDWARE AS REQUIRED. COORDINATE WITH THE SECURITY CONTRACTOR TO CONNECT THE HARDWARE TO THE SECURITY SYSTEM. N CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 LENEL SERVER ORANGE COUNTY LENEL SOC ORANGE COUNTY (E) ACCESS CONTROL PANEL LNL-8000 LNL-1100 INTRUSION ALARM PANEL IAP-P201 24V PS 12V PS KP-IT LAN NETWORK PHONE SYSTEM CONNECTION 120V POWER 20A 2ND FLR ROOF TYPICAL ALARM DEVICES PER PLANS SRI SINGLE READER INTERFACE MODULE 1300 REX A EL CR ACP DR-1504 - HALLW SRI SINGLE READER INTERFACE MODULE 1300 REX A EL CR SRI SINGLE READER INTERFACE MODULE 1300 REX A EL CR SRI SINGLE READER INTERFACE MODULE 1300 REX A EL CR TER RM 2201A SRI SINGLE READER INTERFACE MODULE 1300 REX A EL CR SRI SINGLE READER INTERFACE MODULE 1300 REX A EL CR SRI SINGLE READER INTERFACE MODULE 1300 REX A EL CR SRI SINGLE READER INTERFACE MODULE 1300 REX A EL CR AREA OF WORK 1ST FLR LNL-3300 16 T5-01 11 T5-01 REX CR RELOCATED CARD READER - UNSECURED SIDE - PROVIDE 4" SQ. BOX W/ SINGLE GANG TRIM - REFER TO PLANS FOR DOOR SWING DIRECTION AND DEVICE LOCATIONS MAGNETIC DOOR ALARM CONTACT LINE OF (E) CEILING PROVIDE 3/4" CONDUIT WITH (1) 2- CONDUCTOR 18 AWG. SHIELDED CABLE FOR ELECTRICAL LOCKSET ELECTRIC LOCKSET ELECTRIC TRANSFER HINGE REQUEST TO EXIT - SECURE SIDE PROVIDE 3/4" CONDUIT WITH 6-CONDUCTOR 18 AWG. SHIELDED CABLE FOR CARD READER ALL CABLE TO BE PLENUM RATED AND ROUTED USING EXISTING J- HOOK PATH BACK TO ACCESS CONTROL PANEL - PROVIDE (1) 4- CONDUCTOR 18 AWG FOR READER AND LOCK AND (1) 4-CONDUCTOR 22 AWG FOR COMMUNICATION 9" CABLE THROUGH DOOR PANEL EQ EQ PROVIDE 3/4" CONDUIT WITH 6- CONDUCTOR 18 AWG. SHIELDED CABLE FOR REQUEST TO EXIT PROVIDE 3/4" CONDUIT WITH 2- CONDUCTOR 18 AWG. SHIELDED CABLE FOR MAGNETIC DOOR CONTACT PROVIDE 12"X12"X4" HOFFMAN BOX WITH SRI SINGLE READER INTERFACE MODULE 1300 LNL-3300 12V PS24V PS 120V POWER 20A KP-IT LAN NETWORK RISER SECURITY WIRE RISER LNL-1100 24"X24"X6"HOFFMAN BOX ACCESS CONTROL PANEL 12"X12"X4" HOFFMAN BOX FOR 12V AND 24V POWER SUPPLIES CONTROLLER CARD - 32 CARD READER CAPACITY INPUT MONITORING CONTROL BOARD - 16 INPUT POINTS AND 2 OUTPUT POINTS R No. F LICENSE STATE D O A RCHITECT C AL IFORNIA STEPHE WHITE RENEWAL DATE C-34829 N 08/31/24 SHEET TITLE PROJECT FACILITY FAC NO: BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO.ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. https://my.matterport.com/show/?m=FW21iEbmuiiC:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt 5/20/2024 10:23:58 AM SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) T5-01 DETAILS - SECURITY CA361 1 CAP028060R314412.44 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 NTSDECENTRALIZED SYSTEM 013/4" = 1'-0"SINGLE DOOR W/ CR (DECENTRALIZED)11N/ADECENTRALIZED ACCESS CONTROL PANEL (ACP)16 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 A. CLASSES OF CONCRETE USAGE: ALL NEW CONCRETE 1. PROVIDE f'c=4000 PSI 28 DAY MINIMUM COMPRESSIVE STRENGTH, NORMALWEIGHT CONCRETE, MAXIMUM WATER TO CEMENT RATIO OF 0.45, AND MAX AGGREGATE SIZE OF 3/4". 2. NORMAL WEIGHT AGGREGATE SHALL BE NONREACATIVE AS DETERMINED BY ONE OF THE METHODS OF ASTM C33 APPENDIX XI: METHODS FOR EVALUATING POTENTIAL FOR DELETERIOUS EXPANSION DUE TO ALKAI REACTIVITY OF AN AGGREGATE. AGGREGATES DEEMED TO BE DELETERIOUS OR POTENTIALLY DELETERIOUS MAY BE USED WITH THE ADDITION OF A MATERIAL THAT HAS BEEN SHOWN TO PREVENT HARMFUL EXPANSION IN ACCORDANCE WITH APPENDIX XI OF ASTM C33, WHEN APPROVED BY THE BUILDING OFFICIAL. 3. THE MAXIMUM PERCENTAGE OF POZZOLANS, INCLUDING FLY ASH AND SILICA FUME, AND SLAG CEMENT IN CONCRETE ASSIGNED TO ALL EXPOSURE CATEGORIES SHALL PER THE FOLLOWING: a) THE MAXIMUM PERCENTAGE LIMITS SHALL INCLUDE THE FLY ASH OR OTHER POZZOLANS, SLAB CEMENT, AND SILICA FUME USED IN THE MANUFACTURE OF ASTM C595 AND C1157 BLENDED CEMENTS. b) THE INDIVIDUAL LIMITS SHALL APPLY REGARDLESS OF THE NUMBER OF CEMENTITIOUS MATERIALS IN A CONCRETE MIX. LIMITS ON CEMENTITIOUS MATERIALS FOR CONCRETE 4. THE CONCRETE MIX DESIGNS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL BY THE REGISTERED DESIGN PROFESSIONAL PRIOR TO FABRICATION AND INSTALLATION. B. HORIZONTAL CONSTRUCTION JOINTS IN CONCRETE POURS 1. THERE SHALL BE NO HORIZONTAL CONSTRUCTION JOINTS IN ANY CONCRETE POURS UNLESS SHOWN ON THE DRAWINGS. THE ARCHITECT/ENGINEER SHALL APPROVE ALL DEVIATIONS OR ADDITIONAL JOINTS IN WRITING. C. REINFORCING STEEL 1. ALL REINFORCING STEEL SHALL BE ASTM A 615 GRADE 60 UNLESS NOTED OTHERWISE ON THE DRAWINGS OR IN THESE NOTES. 2. REINFORCING STEEL: PROVIDE REINFORCING STEEL CONFORMING TO ASTM A 706 FOR ALL REINFORCING STEEL REQUIRED TO BE WELDED AND WHERE NOTED ON THE DRAWINGS. 3. HEADED STUD ANCHORS FOR EMBEDDED PLATES: AWS D1.1 TYPE A STUDS MANUFACTURED IN CONFORMANCE WITH SPECIFICATION ASTM A 108 WITH A MINIMUM TENSILE STRENGTH OF 61,000 PSI. D. REINFORCING STEEL COVERAGE 1. REINFORCING STEEL COVERAGE SHOULD CONFORM TO THE COVER SPECIFIED ON DETAILS. COVER SPECIFIED SHALL BE CONSIDERED MINIMUMS THAT MAY REQUIRE INCREASING WHERE REINFORCING STEEL INTERSECTS FOR DIFFERENT MEMBER TYPES. COVER IN STRUCTURAL MEMBERS NOT SPECIFIED IN THE DETAILS SHALL CONFORM TO THE REQUIREMENTS OF ACI 318 UNLESS SPECIFIED OTHERWISE ON THE DRAWINGS. E. SPLICES AND HOOKS IN REINFORCING STEEL 1. SPLICE LOCATION AND TYPE AND HOOKS FOR UNSCHEDULED BEAMS, SLABS AND WALLS: a. BEAMS AND SLABS. UNSCHEDULED BEAMS AND SLABS, INCLUDING GRADE BEAMS, SHALL HAVE CONTINUOUS TOP BARS LAPPED AT MIDSPAN BETWEEN SUPPORTS WITH A CLASS B TENSION SPLICE. BOTTOM BARS SHALL BE LAPPED AT THE SUPPORTS WITH A CLASS B TENSION SPLICE. ALL BEAM BARS SHALL BE HOOKED AT DISCONTINUOUS END, UNLESS NOTED OTHERWISE. FLY ASH OR OTHER POZZOLANS CONFORMING TO ASTM C618 SLAG CEMENT CONFORMING TO ASTM C989 SIICA FUME CONFORMING TO ASTM C1240 TOTAL OF FLY ASH OR OTHER POZZOLANS AND SILICA FUME TOTAL OF FLY ASH OR OTHER POZZOLANS, SLAG CEMENT, AND SILICA FUME CEMENTITIOUS MATERIALS MAXIMUM PERCENT OF TOTAL CEMENTITIOUS MATERIALS BY MASS 25 50 10 35 50 R SHEET TITLE PROJECT FACILITY FAC NO:BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO.ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com S09.23018.00 Autodesk Docs://S09-23018-00 Kaiser SAN 1st Fl GenRad/S09-23018-00 Kaiser SAN 1st Fl GenRad.rvt 5/16/2024 11:56:34 AM S0-01 GENERAL NOTES CA361 1 CAP028060R314412.44 A. GENERAL BUILDING CODE 1. THE CONSTRUCTION DOCUMENTS ARE BASED ON THE REQUIREMENTS OF THE CALIFORNIA BUILDING CODE 2022. 2. BUILDING OCCUPANCY CATEGORY: II (PER CBC TABLE 1604.5) B. SEISMIC DESIGN CRITERIA 1. THE STRUCTURE AND COMPONENTS OF THE BUILDING HAVE BEEN DESIGNED IN ACCORDANCE WITH AFOREMENTIONED BUILDING CODE WITH THE FOLLOWING CRITERIA: a. 0.2 SEC. SPECTRAL ACCELERATION (SS): 1.287G b. 1 SEC. SPECTRAL ACCELERATION (S1): 0.459G c. SITE CLASS: D d. SITE COEFFICIENT, SHORT PERIOD (FA): 1.20 e. SITE COEFFICIENT, 1 SEC. PERIOD (FV): 1.841 f. 0.2 SEC SPECTRAL RESPONSE COEFF. (SDS): 1.029G g. 1 SEC SPECTRAL RESPONSE COEFF. (SD1): 0.57G h. RISK CATEGORY: IV i. OCCUPANCY IMPORTANCE FACTOR, I: 1.0 j. SEISMIC DESIGN CATEGORY: D A. MATERIAL 1. HOT ROLLED STRUCTURAL MEMBERS: ALL HOT ROLLED STEEL PLATES, SHAPES, SHEET PILING, AND BARS SHALL BE NEW STEEL CONFORMING TO ASTM SPECIFICATION A6. 2. ASTM SPECIFICATION AND GRADE: CLEARLY MARK THE GRADE OF STEEL ON EACH PIECE, WITH A DISTINGUISHING MARK VISIBLE FROM FLOOR SURFACES, FOR THE PURPOSE OF FIELD INSPECTION OF PROPER GRADE OF STEEL. UNLESS NOTED OTHERWISE ON THE DRAWINGS, STRUCTURAL STEEL SHALL BE AS FOLLOWS: a. W- AND WT-SHAPES: ASTM A 992. b. C-SHAPES: ASTM A 36 c. L-SHAPES: ASTM A 36 UNO. d. ROUND HSS: ASTM A 500, GRADE C (FY=46 KSI). e. RECTANGULAR HSS: ASTM A 500, GRADE C (FY=50 KSI). f. STEEL PIPES: ASTM A 53 (TYPES E OR S), GRADE B. g. BASE PLATES: ALL BASE PLATES SHALL CONFORM TO ASTM A 36 UNLESS NOTED OTHERWISE ON THE DRAWINGS. h. CONNECTION MATERIAL: 1) ALL CONNECTION MATERIAL, EXCEPT AS NOTED OTHERWISE HEREIN OR ON THE DRAWINGS, INCLUDING BEARING PLATES, GUSSET PLATES, STIFFENER PLATES, FILLER PLATES, ANGLES, ETC. SHALL CONFORM TO ASTM A 36 UNLESS A HIGHER GRADE OF STEEL IS NOTED ON OTHERWISE. i. OTHER STEEL: ANY OTHER STEEL NOT INDICATED OTHERW ISE SHALL CONFORM TO ASTM A 992 OR ASTM A 572, GRADE 50, EXCEPT PLATES AND ANGLES THAT SHALL BE ASTM A 36. B. STRUCTURAL BOLTS AND THREADED FASTENERS 1. A 325 BOLTS: ALL BOLTS IN STRUCTURAL CONNECTIONS SHALL CONFORM TO ASTM A 325 TYPE 1, UNLESS INDICATED OTHERWISE ON THE DRAWINGS. 2. THREADED ROUND STOCK: THREADED RODS SHALL CONFORM TO: a. ASTM A 36 UNO. 3. ALL OFF-SITE FABRICATION OF STRUCTURAL STEEL COMPONENTS INCLUDING STEEL STAIRS AND PRE-CAST CONCRETE SHALL BE DONE IN AN APPROVED FABRICATOR SHOP AS REQUIRED BY CITY OF SANTA ANA. THE RECEIPT OF ANY SHIPMENT OF OFF-SITE FABRICATED ITEMS 4. NOMINAL HOLE DIMENSIONS SHALL BE STANDARD SIZE PER AISC TABLE J3.3, UNLESS NOTED OTHERWISE. A. SUBMITTALS TO BE PROVIDED TO STRUCTURAL ENGINEER MEP EQUIPMENT DEFERRED SUBMITTALS STRUCTURAL STEEL PREQUALIFIED WELD PROCEDURES & WELDER CERTIFICATIONS CONCRETE RINFORCING STEEL CONCRETE MIX DESIGNS POST INSTALLED ANCHOR MANUFACTURER INFORMATION REINFORCEMENT SCAN AND LOCATIONS CONCRETE SAWCUT LAYOUT UNISTRUCT SYSTEMS AND PRODUCT DATA 1. SUBMITTAL REQUIREMENTS: a. ALL SHOP DRAWINGS MUST BE REVIEWED AND ELECTRONICALLY STAMPED BY THE GENERAL CONTRACTOR PRIOR TO SUBMITTAL. b. CONTRACTOR SHALL PROVIDE THE SUBMITTAL IN ELECTRONIC PORTABLE DOCUMENT FORMAT (PDF). c. THE OMISSION FROM THE SHOP DRAWINGS OF ANY MATERIALS REQUIRED BY THE CONTRACT DOCUMENTS TO BE FURNISHED SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF FURNISHING AND INSTALLING SUCH MATERIALS, REGARDLESS OF WHETHER THE SHOP DRAWINGS HAVE BEEN REVIEWED AND APPROVED. B. REPRODUCTION 1. THE USE OF ELECTRONIC FILES OR REPRODUCTIONS OF THESE CONTRACT DOCUMENTS BY ANY CONTRACTOR, SUBCONTRACTOR, ERECTOR, FABRICATOR, OR MATERIAL SUPPLIER IN LIEU OF PREPARATION OF SHOP DRAWINGS SIGNIFIES THEIR ACCEPTANCE OF ALL INFORMATION SHOWN HEREON AS CORRECT, AND OBLIGATES THEMSELVES TO ANY JOB EXPENSE, REAL OR IMPLIED, ARISING DUE TO ANY ERRORS THAT MAY OCCUR HEREON. A. CONTRACT DOCUMENTS 1. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO OBTAIN ALL CONTRACT DOCUMENTS AND LATEST ADDENDA AND TO SUBMIT SUCH DOCUMENTS TO ALL SUBCONTRACTORS AND MATERIAL SUPPLIERS PRIOR TO THE SUBMITTAL OF SHOP DRAWINGS, FABRICATION OF ANY STRUCTURAL MEMBERS, AND ERECTION IN THE FIELD. 2. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE, AND, EXCEPT WHERE SPECIFICALLY SHOWN, DO NOT INDICATE THE METHOD OR MEANS OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, PROCEDURES, TECHNIQUES, AND SEQUENCE. B. DRAWING CONFLICTS 1. THE GENERAL CONTRACTOR SHALL COMPARE THE ARCHITECTURAL AND STRUCTURAL DRAWINGS AND REPORT ANY DISCREPANCY BETWEEN EACH SET OF DRAWINGS AND WITHIN EACH SET OF DRAWINGS TO THE ARCHITECT AND ENGINEER PRIOR TO THE FABRICATION AND INSTALLATION OF ANY STRUCTURAL MEMBERS. C. CONFLICTS IN STRUCTURAL REQUIREMENTS 1. WHERE CONFLICT EXISTS AMONG THE VARIOUS PARTS OF THE STRUCTURAL CONTRACT DOCUMENTS, STRUCTURAL DRAWINGS, GENERAL NOTES, AND SPECIFICATIONS, THE STRICTEST REQUIREMENTS, AS INDICATED BY THE ENGINEER, SHALL GOVERN. D. EXISTING CONDITIONS 1. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF THE EXISTING BUILDING AT THE JOB SITE AND REPORT ANY DISCREPANCIES FROM ASSUMED CONDITIONS SHOWN ON THE DRAWINGS TO THE ARCHITECT AND ENGINEER PRIOR TO THE FABRICATION AND ERECTION OF ANY MEMBERS. 2. WORK SHOWN ON THE DRAWINGS IS NEW, UNLESS NOTED AS EXISTING. 3. EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS WAS OBTAINED FROM EXISTING CONSTRUCTION DOCUMENTS AND LIMITED SITE OBSERVATION. THESE DRAWINGS OF EXISTING CONSTRUCTION ARE AVAILABLE FOR CONTRACTOR USE. HOWEVER, THE AVAILABLE DRAWINGS OF EXISTING CONSTRUCTION ARE NOT NECESSARILY COMPLETE. THE CONTRACTOR SHALL FIELD VERIFY ALL PERTINENT INFORMATION. 4. DEMOLITION, CUTTING, DRILLING, ETC. OF EXISTING WORK SHALL BE PERFORMED WITH GREAT CARE SO AS NOT TO JEOPARDIZE THE STRUCTURAL INTEGRITY OF THE EXISTING BUILDING. IF ANY ARCHITECTURAL, STRUCTURAL, OR MEP MEMBERS NOT DESIGNATED FOR REMOVAL INTERFERE WITH THE NEW WORK, THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY AND APPROVAL OBTAINED PRIOR TO REMOVAL OF THOSE MEMBERS. 5. THE CONTRACTOR SHALL SAFELY SHORE EXISTING CONSTRUCTION WHEREVER EXISTING SUPPORTS ARE REMOVED TO ALLOW THE INSTALLATION OF NEW WORK. ALL SHORING METHODS AND SEQUENCING OF DEMOLITION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND HIS ENGINEER. 6. THE CONTRACTOR SHALL VERIFY THE LOCATION OF EXISTING UTILITIES PRIOR TO THE START OF CONSTRUCTION AND TAKE CARE TO PROTECT EXISTING UTILITIES THAT ARE TO REMAIN IN SERVICE. 7. THE CONTRACTOR SHALL REPAIR ALL DAMAGE CAUSED DURING CONSTRUCTION WITH SIMILAR MATERIALS AND WORKMANSHIP TO RESTORE CONDITIONS TO LEVELS ACCEPTABLE TO THE ARCHITECT. PART I - DESIGN CRITERIA 01 PART IV -STRUCTURAL STEEL 09 PART III - CONCRETE ANCHORAGE 06 PART VI - SUBMITTALS 12 PART VII - MISCELLANEOUS 14 A. NEW EXPANSION BOLTS SHALL BE HILTI KB-TZ2 (ICC ESR 4266) UNO. B. TESTING REQUIREMENTS SHALL BE IN ACCORDANCE WITH CBC 1901.3 1. POST-INSTALLED ANCHOR TEST PROCEDURES SHALL BE BASED ON THE APPROVED ICC EVALUATION REPORT AND CRITERIA IN THIS SECTION. POST INSTALLED ANCHORS SHALL BE TENSION TESTED EXCEPT FOR TORQUE-CONTROLLED (EXPANSION) ANCHORS. REFER TO THE POST INSTALLED ANCHOR TABLES IN THIS SECTION FOR ANCHOR TYPE, TEST FREQUENCY, AND TEST LOADS. ANCHOR TESTS SHALL BE PERFORMED ONLY AFTER EPOXY AND ANCHORAGE BASE MATERIAL HAVE ACHIEVED FULL STRENGTH AND CURING TIME. 2. TEST ACCEPTANCE CRITERIA SHALL BE BASED ON THE APPROVED ICC EVALUATION REPORT AND THE FOLLOWING MINIMUM REQUIREMENTS. a. HYDRAULIC RAM METHOD: ANCHORS TESTED WITH A HYDRAULIC JACK OR SPRING LOADED APPARATUS SHALL MAINTAIN THE TEST LOAD FOR A MINIMUM OF 15 SECONDS AND SHALL EXHIBIT NO DISCERNIBLE MOVEMENT DURING THE TENSION TEST. FOR ADHESIVE ANCHORS, WHERE OTHER THAN BOND IS BEING TESTED, THE TESTING APPARATUS SUPPORT SHALL NOT BE LOCATED WITHIN 1.5 TIMES THE ANCHORS EMBEDMENT DEPTH TO AVOID RESTRICTING THE CONCRETE SHEAR CONE TYPE FAILURE MECHANISM. b. TORQUE WRENCH METHOD: TORQUE-CONTROLLED POST-INSTALLED ANCHORS TESTED WITH A CALIBRATED TORQUE WRENCH SHALL ATTAIN THE SPECIFIED TORQUE WITHIN 1/2 TURN OF THE NUT, OR ONE QUARTER TURN OF NUT FOR A 3/8" SLEEVE ANCHOR ONLY. 3. TESTING SHALL BE DONE IN THE PRESENCE OF THE SPECIAL INSPECTOR AND A REPORT OF THE TEST RESULTS SHALL BE SUBMITTED TO THE EOR. IF ANY ANCHOR FAILS TESTING THEN ALL ANCHORS OF THE SAME TYPE SHALL BE TESTED UNTIL 20 CONSECUTIVE ANCHORS PASS OR ALL ANCHORS HAVE BEEN TESTED, WHICHEVER IS LESS. TEST FREQUENCY AS NOTED IN THE ANCHOR TABLES BELOW CAN THEN BE RESUMED ON THE REMAINING ANCHORS. 4. TESTING IS NOT REQUIRED FOR POWER ACTUATED FASTENERS USED TO ATTACH TRACKS OF INTERIOR NON-SHEAR WALL PARTITIONS FOR SHEAR ONLY AND WHERE A MINIMUM OF 3 FASTENERS ARE USED PER TRACK SEGMENT. 5. TEST 50% OF ANCHORS C. WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING NON- PRESTRESSED REINFORCED CONCRETE, USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE EXISTING REINFORCING BARS. WHEN INSTALLING THEM INTO EXISTING PRESTRESSED CONCRETE (PRE- OR POST TENSIONED) LOCATE THE PRESTRESSED TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION. EXERCISE EXTREME CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION. MAINTAIN A MINIMUM CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED IN ANCHOR AND/OR PIN. 5/8 2 3/4 5 10 4 1/2 40 1/2 2 4 5 1/2 2 3/4 50 3/8 2 4 4 3/8 2 1/2 30 DIA (IN) EFFECTIVE EMBED (IN) MIN. CONCRETE THICKNESS (IN) CRITICAL EDGE DISTANCE (IN) MIN. EDGE DISTANCE (IN)TEST REQUIRED TORQUE (FT-LB) HILTI KB-TZ2 CARBON EXPANSION ANCHOR - CONCRETE PART VIII -SPECIAL INSPECTIONS 16 A. THE OWNER'S TESTING LABORATORY SHALL PROVIDE SPECIAL INSPECTIONS SERVICES IN ACCORDANCE WITH CALIFORNIA BUILDING CODE. B. STATEMENT OF SPECIAL INSPECTIONS 1. THE TESTING LABORATORY SHALL SAMPLE AND TEST MATERIALS AS THEY ARE BEING INSTALLED FOR COMPLIANCE WITH SPECIFIED ACCEPTANCE CRITERIA. THE TESTING LABORATORY WILL REPORT AND INTERPRET THE TEST RESULTS. THE LABORATORY SHALL MONITOR AND REPORT ON THE INSTALLATION OF CONSTRUCTION WORK AND SHALL PERFORM TESTS ON THE COMPLETED CONSTRUCTION AS REQUIRED TO INDICATE CONTRACTOR’S COMPLIANCE WITH THE VARIOUS MATERIAL SPECIFICATIONS GOVERNING THIS WORK. 2. TESTS AND INSPECTIONS SHALL BE CONDUCTED IN ACCORDANCE WITH SPECIFIED REQUIREMENTS, AND IF NOT SPECIFIED, IN ACCORDANCE W ITH THE APPLICABLE STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS OR OTHER RECOGNIZED AND ACCEPTED AUTHORITIES IN THE FIELD. 3. SPECIAL INSPECTOR RESPONSIBILITIES: a. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED TO ASCERTAIN THAT, TO THE BEST OF HIS/HER KNOWLEDGE, IT IS IN CONFORMANCE WITH THE APPROVED DESIGN DRAWINGS. b. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, THE ARCHITECT/ENGINEER, AND THE OWNER. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT/ENGINEER, CONTRACTOR, AND OWNER. A REPORT THAT THE CORRECTED WORK HAS BEEN INSPECTED SHALL BE SENT TO THE BUILDING OFFICIAL, THE ARCHITECT/ENGINEER, AND THE OWNER. C. QUALIFICATIONS: 1. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE BUILDING OFFICIAL, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION BEING INSPECTED. THE SPECIAL INSPECTOR SHALL MEET THE LEGAL QUALIFICATIONS OF THE BUILDING CODE HAVING JURISDICTION AND BE ON THE APPROVED LIST OF THE CITY OF SANTA ANA. 2. THE TESTING LABORATORY SHALL MEET THE BASIC REQUIREMENTS OF ASTM E 329 AND SHALL SUBMIT TO THE OWNER, ARCHITECT, AND ENGINEER EVIDENCE OF CURRENT ACCREDITATION FROM THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION, THE AASHTO ACCREDITATION PROGRAM OR THE “NIST” NATIONAL VOLUNTARY LABORATORY ACCREDITATION PROGRAM. 3. THE SPECIAL INSPECTOR SHALL BE CERTIFIED WITH VALID AND CURRENT CERTIFICATIONS AND ON THE APPROVED LIST OF THE CITY OF SANTA ANA. 4. QUALIFICATIONS OF WELDING INSPECTORS: INSPECTORS PERFORMING VISUAL WELD INSPECTION SHALL MEET THE REQUIREMENTS OF AWS D1.1 SECTION 6.1.4. INSPECTORS SHALL HAVE CURRENT CERTIFICATION AS AN AWS CERTIFIED WELDING INSPECTOR (CWI). ASSISTANT INSPECTORS, IF ANY, SHALL BE SUPERVISED BY AN INSPECTOR AND SHALL BE QUALIFIED BY TRAINING AND EXPERIENCE TO PERFORM THE SPECIFIC FUNCTIONS TO WHICH THEY ARE ASSIGNED. 5. QUALIFICATIONS OF STEEL INSPECTORS: PERFORMED BY QUALIFIED TECHNICIANS WITH A MINIMUM OF TWO YEARS OF EXPERIENCE IN STRUCTURAL STEEL TESTING AND INSPECTION. D. TESTING REQUIREMENTS 1. CONCRETE a. VERIFY ALL OPENINGS, SAWCUTS, AND CORING ARE THE CORRECT SIZE AND LOCATION. VERIFY THAT THE OPENINGS ARE SHOWN ON THE STRUCTURAL DRAWINGS AND NOTIFY THE ENGINEER IMMEDIATELY OF ANY OPENINGS IN THE FIELD THAT ARE NOT SHOWN ON THE DRAWINGS. 2. ALL POST INSTALLED ANCHORS: VERIFY THAT THE ANCHOR IS INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTALLATION INSTRUCTION AS WELL AS THE FOLLOWING DESIGN REQUIREMENTS: a. TESTING REQUIREMENTS IN ACCORDANCE WITH CBC 1910.5. b. ANCHOR MANUFACTURER AND PRODUCT, INCLUDING MATERIAL, IS IN ACCORDANCE WITH DESIGN DRAWINGS OR APPROVED SUBSTITUTION. c. ANCHOR DIAMETER, LENGTH AND INSTALLED EMBEDMENT DEPTH. d. DRILL BIT TYPE AND DIAMETER. e. ANCHOR EDGE DISTANCE AND SPACING. f. HOLE DIAMETER AND DEPTH. g. HOLE CLEANING PROCEDURE AND CLEANLINESS. 3. STEEL a. THE TESTING LABORATORY SHALL PROVIDE TEST REPORTS OF INSPECTIONS. ALL TEST REPORTS SHALL INDICATE TYPES AND LOCATIONS OF DEFECTS FOUND DURING INSPECTION, THE MEASURES REQUIRED AND PERFORMED TO CORRECT SUCH DEFECTS, STATEMENTS OF FINAL APPROVAL OF WELDING AND BOLTING OF SHOP AND FIELD CONNECTIONS, AND OTHER FABRICATION AND ERECTION DATA PERTINENT TO THE SAFE AND PROPER WELDING AND BOLTING OF SHOP AND FIELD CONNECTIONS. WELD INSPECTION REPORTS SHALL BE SIGNED BY AN INSPECTOR WITH CURRENT CERTIFICATION AS AN AWS CERTIFIED WELDING INSPECTOR (CWI). IN ADDITION TO THE PARTIES LISTED IN THIS SPECIFICATION, THE FABRICATOR AND ERECTOR SHALL RECEIVE COPIES OF THE TEST REPORTS. b. REJECTION OF MATERIAL OR WORKSMANSHIP: THE OWNER, ARCHITECT, ENGINEER, AND TESTING LABORATORY RESERVE THE RIGHT TO REJECT ANY MATERIAL OR WORKSMANSHIP NOT IN CONFORMANCE WITH THE CONTRACT DOCUMENTS AT ANY TIME DURING THE PROGRESS OF THE WORK. HOWEVER, THIS PROVISION DOES NOT ALLOW WAIVING THE OBLIGATION FOR TIMELY, IN SEQUENCE INSPECTIONS. c. REVIEW FIELD WELDER QUALIFICATIONS BY CERTIFICATION OR VERIFY BY RETESTING. OBTAIN WELDER CERTIFICATES. 4. WELD INSPECTION AND PROCESS MONITORING: a. WELDS PERFORMED IN THE FABRICATING SHOP MAY BE INSPECTED IN THE FIELD UNLESS CONTINUOUS MONITORING OF THE WELDING PROCESS IS HEREIN SPECIFIED OR IF ACCESS IN THE FIELD DUE TO OTHER WORK OR SHOP FINISHES MAKES FIELD INSPECTION IMPRACTICAL. b. APPROVE WELDING PROCEDURE SPECIFICATIONS SUBMITTED BY THE CONTRACTOR. APPROVE ANY CHANGES SUBMITTED BY THE CONTRACTOR TO ANY WPS THAT HAS ALREADY BEEN APPROVED. OBTAIN THE WELDING PROCEDURE QUALIFICATION RECORD (WPQR) FOR EACH SUCCESSFUL WPS QUALIFICATION. E. A FINAL INSPECTION REPORT FOR ALL ITEMS REQUIRING SPECIAL INSPECTION SHALL BE COMPLETED AND SUBMITTED TO THE CITY OF ANAHEIM INSPECTION DIVISION. PART II -REINFORCED CONCRETE 02 3 3/4 2 1/2 3 4 1/2 110 3/4 3 1/4 2 1/2 3 4 1/2 110 4 2 1/2 3 4 1/2 40 5/8 2 3/4 2 1/2 3 4 1/2 40 3 1/4 2 1/2 3 4 1/2 50 1/2 2 2 1/2 3 4 1/2 50 2 1/2 2 1/2 3 4 1/2 30 2 2 1/2 3 4 1/2 30 3/8 1 1/2 2 1/2 3 4 1/2 30 DIA (IN) EFFECTIVE EMBEDMENT (IN) MINIMUM CONCRETE THICKNESS OVER METAL DECK (IN) MAXIMUM DEPTH OF METAL DECK (IN) MINIMUM WIDTH OF CELL BOTTOM (IN) REQUIRED TORQUE (FT LB) HILTI KB-TZ2 EXPANSION ANCHOR - SOFFIT OF CONCRETE FILLED DECK (f'c = 3,000 PSI MINIMUM) 16 INSPECT FORMWORK FOR SHAPE, LOCATION, AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED PERIODIC ACI 318: 26.11.1.2(b) 15 VERIFY MAINTENANCE OF SPECIFIED CONCRETE CURING TEMPERATURE AND TECHNIQUES PERIODIC ACI 318: 26.5.3-26.5.5 14 INSPECT CONCRETE FOR PROPER APPLICATION TECHNIQUES CONTINUOUS ACI 318: 26.5 13 PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF CONCRETE CONTINUOUS ASTM C172 ASTM C31 ACI 318: 26.5, 26.12 12 VERIFY USE OF REQUIRED CONCRETE DESIGN MIX PERIODIC ACI 318: 19, 26.4.3, 26.4.4 11 INSPECT POST-INSTALLED MECHANICAL ANCHORS AND ADHESIVE ANCHORS WHICH ARE NOT DEFINED IN (10) PERIODIC ACI 318: 17.8.2, 17.8.2.4 10 INSPECT POST INSTALLED ADHESIVE ANCHORS IN HORIZONTALLY OR UPWARDLY INCLINED ORIENTATIONS CONTINUOUS ACI 318: 17.8.2, 17.8.2.4 9 INSPECT CONCRETE REINFORCEMENT AND VERIFY PLACEMENT PERIODIC ACI 318: 20, 25.2, 25.3, 26.6-1-26.6-3 CONCRETE TESTING AND INSPECTION (CBC TABLE 1705.3) 8 WELDING SINGLE-PASS FILLET WELDS ≤ 5/16" PERIODIC AWS D1.1 7 WELDING SINGLE-PASS FILLET WELDS > 5/16" CONTINUOUS AWS D1.1 6 WELDING MULTI-PASS FILLET WELDS CONTINUOUS AWS D1.1 5 WELDING COMPLETE AND PARTIAL PENETRATION GROOVE WELDS CONTINUOUS AWS D1.1 4 MATERIAL VERIFICATION OF WELD FILLER MATERIALS. IDENTIFICATION MARKINGS TO CONFORM TO AWS SPECIFICATION APPROVED IN CONSTRUCTION DOCUMENTS PERIODIC ANSI/AISC 360: A3.5 WELDING TESTING AND INSPECTION (CBC SECTION 1705.2.1) 3 STRUCTURAL STEEL CERTIFIED MILL TEST REPORTS PERIODIC ANSI/AISC 360: A3 2 STRUCTURAL STEEL IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED ON THE APPROVED CONSTRUCTION DOCUMENTS PERIODIC ANSI/AISC 360: A3 1 MATERIAL VERIFICATION OF BOLTS, NUTS, AND WASHERS. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS PERIODIC ASTM ANSI/AISC 360: A3.3 STRUCTURAL STEEL TESTING AND INSPECTION (CBC SECTION 1705.2.1) ITEM TESTING AND INSPECTION FREQUENCY CODE REFERENCE A. MATERIAL 1. ALL UNISTRUT FRAMING MEMBERS SHALL BE EITHER A1011 SS GR33 OR SHALL BE A653 GR 33 PER MANUFACTURER SPECIFICATIONS. 2. ALL BOLTS AND NUTS SHALL HAVE UNIFIED COARSE SCREWS AND BE ASTM A576 GR1015 OR A1011SS GR 45 PER MANUFACTURER SPECIFICATIONS UNLESS NOTED OTHERWISE ON PLANS AND DETAILS. 3. ALL FITTINGS ARE PUNCH-PRESS FROM HOT ROLLED, PICKLED, AND OILED STEEL PLATES, STRIP OR COIL AND SHALL CONFORM TO ASTM A575, A576, A635, A1011 SS GR33, OR A36 PER MANUFACTURER SPECIFICATIONS. B. BOLT TORQUE VALUES SHALL BE ACHIEVED AS FOLLOWS PER THE UNISTRUT SPECIFICATIONS (UNLESS NOTED OTHERWISE ON PLAN): 1. 1/4" BOLT = 6LB-FT MINIMUM, 7LB-FT MAXIMUM 2. 5/16" BOLT = 11LB-FT MINIMUM, 15LB-FT MAXIMUM 3. 3/8" BOLT = 19LB-FT MINIMUM, 25LB-FT MAXIMUM 4. 1/2" BOLT = 50LB-FT MINIMUM, 70LB-FT MAXIMUM 5. 5/8" BOLT = 100LB-FT MINIMUM, 125LB-FT MAXIMUM 6. 3/4" BOLT = 125LB-FT MINIMUM, 135LB-FT MAXIMUM C. MANUFACTURER QUALIFICATIONS 1. THE MANUFACTURER SHALL NOT HAVE HAD LESS THAN 10 YEAR'S EXPERIENCE IN MANUFACTURING STRUT SYSTEMS. 2. THE MANUFACTURER MUST CERTIFY ALL COMPONENTS SUPPLIED HAVE BEEN PRODUCED IN ACCORDANCE WITH AN ESTABLISHED QUALITY ASSURANCE PROGRAM. D. INSTALLER QUALIFICATIONS 1. INSTALL MUST BE A UNISTRUT TRAINED MANUFACTURER'S AUTHORIZED REPRESENTATIVE/INSTALLER WITH NOT LESS THAN 5 YEARS EXPERIENCE IN THE INSTALLATION OF STRUT SYSTEMS. E. DURING INSTALLATION, IT SHALL BE THE RESPONSIBILITY OF THE INSTALLER TO PROTECT THE UNISTRUT SYSTEM FROM DAMAGE. UPON THE COMPLETION OF INSTALLATION, IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO PROTECT THE UNISTRUT SYSTEM FROM DAMAGE DURING THE REMAINDER OF CONSTRUCTION UNTIL SUBSTANTIAL COMPLETION. PART V - UNISTRUT SPECIFICATIONS 11 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 OS OS OS OS OS OS 2.7 2.5 2.3 1.4 F G H J K 1501 LOBBY LOBBY 1529 ENVIRONMENTAL SERVICES CLOSET EVSRM 1509 STORAGE, GENERAL SGENL 1507 IMAGING, MAMMOGRAPHY IMAMO 1506 IMAGING, GEN IGENL 1513 ACCESSIBLE DRESSING BOOTH DRSSA 1502 CORRIDOR CORRD 1517 TOILET/LAV, GENERAL TLGEN 1518 TOILET/LAV, GENERAL TLGEN 1505 SHELL SPACE SHELL 1617 OFFICE, PROVIDER OPROV 1602 HALLWAY HALLW 1701 WAITING AREA, GENERAL WTAGN 1507A ACCESSIBLE DRESSING BOOTH DRSSA 30"X36" CLR 1506A CONTROL ROOM CRRAD 1514 TECH WORKSTATION WSGEN 1504B HALLWAY HALLW 15 0 5 1504 15 0 6 15 1 1 1511 DRESSING BOOTH DRSSB 15 1 3 1504A HALLWAY HALLW 1510 SUBWAIT ROOM 1508 HALLWAY HALLW 1 2.7 2.5 2.3 1.4 F G H J K 2 RAUN 216-8 RAUN 216-5 RAUN 216-6 4'-0" 4' - 0 " 4' - 0 " 5'-0" SAWCUT PER (E) 4" THICK SLAB-ON-GRADE, f'c=3000PSI STEEL FOR HALF HEIGHT WALL PER SAWCUT PER 23/S5-01 23/S5-01 19/S5-01 SAWCUT FOR WASTE CONNECTION PER . REF ARCH AND PLUMBING FOR EXTENTS 23/S5-01 1' - 3 " LOCATION WHERE WALL TRANSITIONS TO FULL HEIGHT 1' - 6 " SAWCUT FOR ELECTRICAL CONDUIT BETWEEN RAUN 216-6 AND RAUN 216-5 PER . REF ARCH AND PLUMBING FOR EXTENTS 23/S5-01 RAUN 216-11 2'-0" 2' - 0 " (N) 10" THICK SOG, ECCENTRIC TO FACE OF EXISTING STRUCTURAL WALL AS SHOWN. SAWCUT PER , REINFORCE PER SEE NOTE 4 23/S5-01 18/S5-01 (N) 10" THICK SOG CENTERED ON COLUMN AS SHOWN. SAWCUT PER , REINFORCE PER SEE NOTE 4 23/S5-01 18/S5-01 (N) 10" THICK SOG CENTERED ON COLUMN AS SHOWN. SAWCUT PER , REINFORCE PER 23/S5-01 18/S5-01 2'-0" 2' - 0 " 2'-0" 2' - 0 " (N) 10" THICK SOG CENTERED ON COLUMN AS SHOWN. SAWCUT PER , REINFORCE PER 23/S5-01 18/S5-01 2' - 0 " 2'-0" RAUN 216-9 AND RAUN 216-10 1'-8"2'-2" 2'-2" 2'-2" 2'-2" 2'-2" 2.7 2.5 2.3 1.4 F G H J K 2 1'-0" HS S 8 x 4 x 3 / 8 HS S 8 x 4 x 3 / 8 HSS8x4x3/8 HSS8x4x3/8 HSS8x4x3/8 (4) HSS5x5x3/8 POSTS LOCATED IN NEW WALLS PER P1001 UNISTRUT SPANNING BETWEEN HSS BEAMS TO SUPPORT CEILING EQUIPMENT, PER 13/S5-01 03/S5-01 1'-8" 9" 1' - 0 " EQ E Q 11" 4" 1.CONTRACTOR SHALL FIELD VERIFY EXISTING DIMENSIONS AND PROVIDE A SUBMITTAL TO THE ARCHITECT AND ENGINEER PRIOR TO STEEL FABRICATION. FIELD VERIFICATION TO IDENTIFY ALL CONFLICTS WITH EXISTING STRUCTURE PRIOR TO STEEL FABRICATION. 2.REFER TO EQUIPMENT SCHEDULE ON FOR BALANCE OF EQUIPMENT INFO. 3. 2ND FLOOR FRAMING IS SHOWN WITH CEILING AND EQUIPMENT BELOW THE 2ND FLOOR. 4.CONTRACTOR RESPONSIBLE TO VERIFY EXISTING FOUNDATION PRIOR TO SAWCUTING PROCEDURE. ANY DISCREPANCIES FROM ASSUMED CONDITIONS SHOWN ON THE DRAWINGS SHALL BE REPORTED TO STRUCTURAL ENGINEER PRIOR TO DEMOLITION, FABRICATION AND ERECTION OF ANY MEMBERS. 01/S5-01 N NOT APPLICABLE, LEGEND NOT REQUIRED. NOT APPLICABLE, SHEET KEYNOTES NOT REQUIRED. R SHEET TITLE PROJECT FACILITY FAC NO:BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO.ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com S09.23018.00 Autodesk Docs://S09-23018-00 Kaiser SAN 1st Fl GenRad/S09-23018-00 Kaiser SAN 1st Fl GenRad.rvt 5/16/2024 11:56:35 AM S1-13 PLAN - REMODEL 1ST FLR CA361 1 CAP028060R314412.44 1/4" = 1'-0"PLAN - REMODEL 1ST FLR 01 1/4" = 1'-0"PLAN - REMODEL 2ND FLR 03 GENERAL NOTES SHEET KEYNOTES LEGEND KEY PLAN SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) N N CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 A A A A B B 9 13/16"6 3/4" 3 1/8" 1 1 / 4 " 2 5 / 1 6 " 5 1 / 2 " 1' - 0 5 / 8 " 1/ 8 " 2 1/4"3 1 / 4 " 1'-2 9/16" 1'-3 1/2" 1'-7 11/16" 1 1 / 4 " 10 1 / 1 6 " WALL STAND BASE OUTLINE ANCHOR POINTS 4-5/8"⌀HILTI KB-TZ2 (NOMINAL EMBED = 3 1/4") ICC ESR 4266 BASE DETAIL 0 NEW 5" THICK SLAB-ON-GRADE PER 18/S5-01 7' -0" 1 2 2 1 PRIMARY MOUNTING HOLES ALTERNATE MOUNTING HOLES 1 2 NEW SLAB 4'-0"x4'-0" MIN NOTE: 1. REFER FOR SAWCUT PROCEDURE.23/S5-01 23/S5-01 18/S5-01 1'-1 1/2" 1'-0 7/8" 1'-2 7/16" 1'-2 7/16" 10 5 / 8 " 1' - 1 3 / 4 " 11 1 3 / 1 6 " CG TABLE BASE OUTLINE ANCHOR POINTS PRIMARY MOUNTING HOLES ALTERNATE MOUNTING HOLES 1 2 2 1 2 1 2 1 2 1 FRONT HEAD-END FRONT OF TABLE BASE TABLE CG 7'-10 3/4" 4 - 5/8" DIA HILTI KB-TZ2 MIN EMBED nom = 3 1/4" ICC#4266 1' - 4 1 5 / 1 6 " 2'-7 1/2" 3 1 / 8 " 3' - 1 1 / 2 " M A X NEW 5" PER SLAB-ON-GRADE NOTE: 1. REFER FOR SAWCUT PROCEDURE. 4'-0"x5'-0" MIN CL BACKING 3 5/8" 16 GAGE METAL STUD (50KSI) @ 16"OC MIN. ELEVATION 7' - 4 " COG BACKING, REFER DETAIL 21/S5-01 1/2"⌀BOLT EACH TO CABINET RAUF 207-5 GENERATOR CABINET (E) CONCRETE SLAB-ON-GRADE 1' - 5 1 / 8 " 2'-7 1/2" EQ EQ PLAN COG STUDS BACKING 2'-3 1/2" L4x3x1/4x0'-4" LLH WITH (3) #10" SMS (ICC ESR 3006) 3' - 7 1 / 2 " 1'-11 5/8" 3/8" ⌀HILTI-KBTZ 2 (ICC ESR 4266), NOMINAL EMBED 2 1/2" 1' - 2 " ANCHORS AT TOP ANCHORS AT BASE 8" EXTEND BACKING AN ADDITIONAL STUD ON EACH SIDE OF WALL ANCHORS EQ E Q #4@12" DOWELS EACH SIDE WITH HILTI HY200 (EMBED -4 1/2") ICC #3187 EXIST 4" SLAB- ON-GRADE NEW SLAB REINFORCE WITH #4@12" EACH WAY NEW SLABEXIST SLAB NOTE: 1. REFER FOR SAWCUT PROCEDURE. 2. COMPACT SOIL TO 95% RELATIVE COMPACTION. 3. REPLACE VAPOR BARRIER SYSTEM AS REQUIRED TO MATCH EXISTING. 23/S5-01 12" MIN 3" C L R T Y P 3" CLR TYP NOTE: 1. ENGINEER'S RECOMMENDED PROCEDURE TO SAWCUT PROPOSED OPENING INTO EXISTING CONCRETE SLAB: STEP 1: LAYOUT PROPOSED SAWCUT AREA STEP 2: CORE DRILL EACH CORNER, RECOMMEND 4" MIN DIA CORE DRILL. STEP 3: SAWCUT OPENING. DO NOT CUT BEYOND PROPOSED OPENING EXTENTS. STEP 4: REMAINING CONCRETE AT CORNER TO BE CHIPPED OUT. TAKE SPECIAL CARE NOT TO DAMAGE CONCRETE OUTSIDE OF PROPOSED OPENING. CONTRACTOR MAY USE ALTERNATIVE MEANS AND METHODS TO PRODUCE OPENING IF SUCH METHOD DOES NOT DAMAGE CONCRETE OUTSIDE OF OPENING EXTENTS AND SHALL SUBMIT ALTERNATIVE TO THE STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL. SAWCUT EXTENTS, PER TO ARCH/MEP. DO NOT OVERCUT BEYOND PROPOSED OPENING EXTENTS. SEE NOTE 1 REMAINING CONCRETE AT CORNER TO BE CHIPPED OUT. TAKE SPECIAL CARE NOT TO DAMAGE CONCRETE OUTSIDE OF PROPOSED SAWCUT. SEE NOTE 1 4"⌀CORE DRILLED HOLE EACH CORNER OF PROPOSED SAWCUT. SEE NOTE 1 STUD EACH SIDE OF HSS HSS 3x3x3/8" AT 3'-0" OC, ON EACH SIDE OF WINDOW, AND AT END OF WALL 1/2"Ø HILTI KBTZ2 (NOMINAL EMBED = 2 1/2") ICC ESR 4266 EXISTING SLAB-ON-GRADE 1 1 / 2 " 3 " 3 " 1 1 / 2 " 4" HILTI XU FASTENER @8" OC TYPICAL ICC #2269 BASE PLATE 1/2 x 4" x9" STUD EACH SIDE SECTION A-A 2' - 6 " 7' - 0 " M A X 5/16 L7x4x3/8 LLH TOP AND BOTTOM WITH (2) 3/4"⌀ A307 ALL THREAD THRU ROD, INSTALL FINGER TIGHT AND DAMAGE THREADS TO PREVENT UNRAVELLING 1 1/2" ACCEPTABLE TO FABRICATE A 1/8" GAP AT TOP ANGLE FOR FIELD ERECTION. PROVIDE FINGER SHIMS 3" 2" 5/16 5/16 TYPICAL (1/4) (1/4)TYPICAL (E) PLYWOOD FLOOR L5x3x1/2 LLV EACH SIDE OF HSS (E) FLOOR JOIST HSS POST PER PLAN WITH STD HOLES AT TOP CONNECTION CEILING NOTE: 1.ACCEPTABLE TO TRIM LEG 1" FOR ERECTION PURPOSES AND TO AVOID CLASHES IN THE FIELD. SCREWS TO BE CENTERED ON FINAL LEG WIDTH. 2.FOR BASEPLATE ATTACHMENT AT SOG, REF . 3.CONTRACTOR SHALL FIELD VERIFY EXISTING DIMENSIONS AND PROVIDE A SUBMITTAL TO THE ARCHITECT AND ENGINEER PRIOR TO STEEL FABRICATION. FIELD VERIFICATION TO IDENTIFY ALL CONFLICTS WITH EXISTING STRUCTURE PRIOR TO STEEL FABRICATION. HSS PER PLAN (2) 1/2"⌀A307 ALL THREAD THRU RODS WITH PLATE WASHER EACH SIDE (1/4" X 2"X2") SECTION A-A VERT SLOTTED HOLE = 2" LONG, CENTERED ON ANGLE LEG 2"2" 1 1/2" 2" 1 1/2" 1" EQ EQEQ EQ 1/4"⌀x3" LAG SCREW CENTERED ON HORIZONTAL, TYPICAL P1000 UNISTRUT BRACING EACH SIDE (4 TOTAL) REF FOR UPPER ATTACHMENT 04/S5-01 2x6 HORIZONTAL BLOCKING 09/S5-01 SECTION B-B 1/2"⌀A307 WITH WASHERS THRU BOLT, TYP P1843 FITTING WITH 1/2"⌀BOLT 5/16 5/16 (1/4) (1/4)PJP EQ EQ 1 1 / 2 " 1 1 / 2 " RECTANGULAR BASE PL3/8. ACCEPTABLE TO ROTATE 90 TO FIT WITHIN OR PARALLEL TO ARCHITECTURAL WALLS 1 1 / 2 " 1 1 / 2 " 3/4"⌀HILTI KB-TZ2 (ICC ESR 4266) WITH 4" NOMINAL EMBED HSS POST PER PLAN NOTE: 1.REFER TO FOR BALANCE OF INFO.13/S5-01 ACCEPTABLE TO PROVIDE 1/2" MAX GROUT FOR LEVELING. GROUT TO BE f'c=4000PSI NON-SHRINK 1 1 / 2 " 3" 1 1 / 2 " 1 1/2"1/2" GAP L4x4x1/4 EACH SIDE. ACCEPTABLE TO FABRICATE 1/8" GAP ON ONE SIDE FOR FIELD ERECTION, PROVIDE FINGER SHIMS (2) 3/4"⌀A307 ALL THREAD THRU RODS. INSTALL FINGER TIGHT AND DAMAGE THREADS TO PREVENT UNRAVELING 3/16 3/16 TYPICAL (1/4) (1/4)TYPICAL NOTE: 1.REFER TO FOR BALANCE OF INFO. HSS GIRDER PER PLAN HSS BEAM PER PLAN 03/S5-01 L2x2x1/4x0'-4" AT EACH UNISTRUT EACH SIDE AS SHOWN 3/16 3 SIDES, TYP EQUIPMENT RAIL ATTACHED TO UNISTRUT PER MANUFACTURER/OPM 1/4" TO 1/2" GAP ALLOWED FOR FIELD INSTALL OF UNISTRUT CEILING (1/4)TYP EXTENSION 1" MIN NOTE: 1.REFER TO AND FOR BALANCE OF INFO. HSS BEAM PER PLAN UNISTRUT PER PLAN 08/S5-01 13/S5-01 EXTEND UNISTRUT AS SHOWN FOR CONNECTION 21/S5-01 11/S5-01 01/S5-02 01/S5-02 16/S5-01 02/S5-01 EQ E Q EQ EQ 21 1/2" 3 3 / 4 " 16 9 / 1 6 " 14" (2) 1/4" SMS AS SHOWN (ICC ESR 3006) COG (E) TOP OF FLOOR CENTERLINE OF 6" 16 GAGE BACKING. REFER TO 07/S5-01 3-#10 SMS TYP EXISTING OR NEW IF NOT EXISTING 4" 16GA STUDS @16" (PER NOTE 2) CONT 600T150-54 BACKING (UNPUNCHED) CUT LEG AT STUD TYP PER NOTE 1 BACKING LENGTH NOTES: 1. 3 STUD SPACES MINIMUM, UNO AND 1 STUD SPACE BEYOND EQUIPMENT EACH END. 2. CONTRACTOR SHALL VERIFY EXISTING STUDS AND NOTIFY THE ARCHITECT AND STRUCTURAL ENGINEER OF ANY DISCREPANCIES. 3/8" MIN 3/4" MIN P1000 BRACING PROVIDE 2x6 HORIZONTAL BLOCKING P1000 BRACE. EXTEND HORIZONTAL BLOCKING ONE BAY BEYOND BRACE EACH SIDE AS SHOWN 6" MAX 1/2"⌀A307 WITH WASHERS THRU BOLT, TYP (4) 0.160x3" STRONG DRIVE SDWS SCREWS EACH EXISTING JOIST 1/4" BENT PLATE GRADE A36, TYP NOTE: 1. REFER TO FOR BALANCE OF INFO.13/S5-01 P1843 FITTING WITH 1/2"⌀BOLT DUCT REF NOTES #1&2 SAWCUT FOR NEW TRENCH NEW CONCRETE SLAB f'c = 4000 PSI MIN #4x14" LONG @12" DOWELS EACH SIDE WITH HILTI HY200 (EMBED = 6") ICC #3187, CENTER ON SLAB PER NOTE #1 NOTES: 1.REFER ARCH FOR LOCATION OF SAWCUT AT SLAB-ON-GRADE. 2.LOCATE REBAR TO NOT CONFLICT WITH TRENCH DUCT. 3.REPLACE VAPOR BARRIER SYSTEM AS REQUIRED TO MATCH EXISTING. 4. REFER DETAIL 23/S5-01 FOR SAWCUT PROCEDURE. 5.FLOOR DUCT SIZE NOT TO EXCEED 5"WIDE X 2 1/2" DEEP MOUNTED FLUSH WITH FINISHED FLOOR. PER NOTE #3 8" SLAB 0 #4@12" CONT (3 MIN) #4@12" 2'-0" TRENCH FOR FLOOR DUCT, NOTE 5 EQ E Q 4" EXISTING SLAB-ON-GRADE 0 1 1/2" CLR R SHEET TITLE PROJECT FACILITY FAC NO:BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO.ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com S09.23018.00 Autodesk Docs://S09-23018-00 Kaiser SAN 1st Fl GenRad/S09-23018-00 Kaiser SAN 1st Fl GenRad.rvt 6/27/2024 11:35:56 AM S5-01 DETAILS CA361 1 CAP028060R314412.44 NO SCALEYSIO MAX WALL STAND 21 NO SCALEYSIO MAX TABLE 11NO SCALEPOLYDOROS R80 GENERATOR CABINET 16 NO SCALENEW TO EXISTING SLAB-ON-GRADE DOWELS 18NO SCALESLAB-ON-GRADE SAWCUT PROCEDURE 23 NO SCALEPARTIAL HEIGHT WALL 19 NO SCALEGENRAD STEEL HSS @ WOOD - POST 13 NO SCALEGENRAD STEEL HSS VERTICAL BASEPLATE 09 NO SCALEGENRAD STEEL HSS @ WOOD - BEAM 08 NO SCALEGENRAD STEEL HSS @ WOOD - UNISTRUT 03 NO SCALEEQUIPMENT SCHEDULE 01 RAUN 216-11 GRID HOLDER 22LB RAUN 216-10 CEILING RAILS FOR X-RAY TUBE SUSPENSION 59 LB RAUN 216-9 3M YSIO MAX AIM FAST BRIDGE AND X-RAY TUBE STAND 846 LB RAUN 216-8 YSIO MAX WALL STAND WITH FIXED DETECTOR 661 LB RAUN 216-6 POLYDOROS R80 (80KW) GENERATOR CABINET 883 LB RAUN 216-5 YSIO MAX TABLE WITH MOBILE DETECTOR 1235 LB (INCLUDE 400LB PATIENT LOAD) EQUIPMENT DESCRIPTION OPERATING WEIGHT DETAIL REFERENCE SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) NO SCALEGRID HOLDER 02NO SCALETYPICAL METAL STUD BACKING 07 NO SCALEUPPER KICKER ATTACHMENT 04NO SCALENEW SAWCUT FOR TRENCH DUCT 24 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 PLAN CHECK CORRECTIONS 07/01/2024PLAN CHECK CORRECTIONS 07/02/2024 1900 E 4th St - 1011190678/9/2024 A A MAX 6" REF PLAN 32 " RAIL STRUCTURE PER PLAN, AND PER DETAILS , , SECTION A-A P1001 SUB RAILS PER PLAN UNISTRUT P1008M10 NUT TO UNISTRUT SUPPORT STRUCTURE SIEMENS EQUIPMENT RAIL C.G. WT SUPPORT POINT (PER SECTION ON A-A) TYPICAL 4' - 1 0 1 / 8 " SIEMENS LONGITUDINAL RAIL C.G. WT EQ EQ TO WHEEL MIN 32" WHEEL TRANSVERSE BRIDGE ELEVATION PLAN CEILING CEILING FLEXIBLE CABLE GUIDERAIL 5" 2' - 1 " 03/S5-01 08/S5-01 09/S5-01 13/S5-01 R SHEET TITLE PROJECT FACILITY FAC NO:BLDG NO:FLOOR LEV:SECTION: KP PROJ. NO. MATTERPORT LINK: 555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA ARCHITECT CONSULTANT ARCHITECT SEAL CONSULTANT SEAL KAISER FOUNDATION HOSPITALS NATIONAL FACILITIES SERVICES 1800 HARRISON STREET OAKLAND, CALIFORNIA 94612 ISSUE / REVISION LOG NO.ISSUED DATE 0 5' 50 ' GR A P H I C S C A L E S : 1/ 1 6 " = 1 ' - 0 " 0 25 ' 1/ 8 " = 1 ' - 0 " 5' 0 12 ' 1/ 4 " = 1 ' - 0 " 1' 0 6' 1/ 2 " = 1 ' - 0 " 1' 0 2' 1- 1 / 2 " = 1 ' - 0 " 0 1' 3" = 1 ' - 0 " IF T H I S S H E E T I S N O T 30 " x 4 2 " , I T I S A R E D U C E D PR I N T - S C A L E AC C O R D I N G L Y AGENCY APPLICATION NUMBER AGENCY APPROVAL STAMP THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. HZ PROJ. NO. Phone 310.820.4600 | Fax 310.207.4215 www.huitt-zollars.com S09.23018.00 Autodesk Docs://S09-23018-00 Kaiser SAN 1st Fl GenRad/S09-23018-00 Kaiser SAN 1st Fl GenRad.rvt 5/16/2024 11:56:37 AM S5-02 DETAILS CA361 1 CAP028060R314412.44 NO SCALENOT USED 21 NO SCALENOT USED 11NO SCALENOT USED 16 NO SCALENOT USED 24 NO SCALENOT USED 18NO SCALENOT USED 23 NO SCALENOT USED 19 NO SCALENOT USED 13 NO SCALENOT USED 09 NO SCALENOT USED 08 NO SCALENOT USED 03 NO SCALENOT USED 04 SANTA ANA MEDICAL OFFICES 1900 E. 4TH ST. SANTA ANA, CA 92701 SOCC 2023 R RAD SAN 1ST FLOOR GEN RAD REPLACEMENT (5284) NO SCALECEILING BRIDGE AND X-RAY TUBE STAND 01 NO SCALENOT USED 12 NO SCALENOT USED 14 NO SCALENOT USED 17NO SCALENOT USED 22 CITY SUBMITTAL 04/19/2024 BID SET 05/20/2024 1900 E 4th St - 1011190678/9/2024 1900 E 4th St - 1011190678/9/2024 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 1900 E 4th St - 1011190678/9/2024 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 1900 E 4th St - 1011190678/9/2024 310.254.1900 main 633 West 5th St, Suite 7200 · Los Angeles, California 90071 STRUCTURAL CALCULATION PACKAGE K a i s e r S A N 1 s t F l o o r G e n R a d SANTA ANA, CALIFORNIA JOB NUMBER S09-23018-00 City Submittal April 19, 2024 1900 E 4th St - 1011190678/9/2024 Select an office phone number. 633 West 5th St, Suite 7200 · Los Angeles, California 90071 TABLE OF CONTENTS 1.00 Floor Mounted Equipment................................................................................................. 3 1.01- RAUN 216-8 - YSI MAX WALL STAND (21/S5-01).............................................................4 1.02- RAUN 216-5 - YSI TABLE (11/S5-01)................................................................................15 1.03- RAUN 216-6 - POLYDOROS R80 (80KW) GENERATOR CABINET (16/S5-01)....................26 1.04-RAUN 216-11 - GRID HOLDER CABINET (02/S5-01)..........................................................37 1.05-PARTIAL HEIGHT WALL (19/S5-01)…………………………........................................................41 2.00 Equipment at ceiling.......................................................................................................... 52 2.01- RAUN 216-10 - Analysis of ceiling structure (01/S5-02)..................................................53 2.02- RAUN 216-10 - Design of ceiling structure (01/S5-02)....................................................68 2.03- RAUN 216-10 – Soil Bearing Check (01/S5-02)................................................................75 2.04- RAUN 216-10 - Hilti Anchorage Report (01/S5-09).........................................................80 1900 E 4th St - 1011190678/9/2024 WALTER P MOORE STRUCTURAL CALCULATIONS 1.00 - Floor Mounted Equipment 1900 E 4th St - 1011190678/9/2024 WALTER P MOORE STRUCTURAL CALCULATIONS 1.01 - RAUN 216-8 - YSI MAX WALL STAND DETAIL 21/S5-01 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- RAUN 216-8 YSI MAX WALL STAND (DETAIL 21/S5-01) Operating Weight (including 400 lb patient) ≔Wp 661 lbf Seismic Parameters ≔SDS 1.029 ≔Ip 1.5 ≔Ωo 1.5 FLOOR ATTACHMENT - MECHANICAL & ELECTRICAL ≔z 0 Component point of attachment elevation with respect to the base ≔h 1 Supporting structure average roof height relative to the base ≔z_h_ratio =―z h 0 ATTACHMENT IS AT 1st FLOOR ≔Fpmax =⋅⋅1.6 SDS Ip 2.47 ≔Fpmin =⋅⋅0.3 SDS Ip 0.463 ≔ap 1.0 ≔Rp 1.5 WALL STANDS SEISMIC PARAMETERS AS PER OSP-280 ≔Fp =⋅―――――⋅⋅0.4 ap SDS ――Rp Ip ((+1 ⋅2 z_h_ratio))0.412 ≔Fp =if else if else >Fpmin Fp ‖ ‖‖Fpmin <Fpmax Fp ‖ ‖‖Fpmax ‖ ‖‖Fp 0.463 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- CALCULATE MOMENT AT BASE ANCHORAGE Equipment Geometry: ≔L 14.563 in ≔B 10.063 in ≔H 84 in (Lenght) (Front of cab.) (Width) (Depth of cab.) (Height) ≔hc =⋅―5 7 H 60 in Location of centroid along height of cabinet. Excentricity from centroid along Length, L. "ex" is to the left edge , "ey" is to the right edge≔ex 0 in ≔ey ⋅0 in ≔nL 2 ≔nB 2 ≔n =⋅nL nB 4 Number of anchors along L and B. ≔EH =⋅Fp Wp 306.08 lbf ≔EHΩ =⋅⋅Ωo Fp Wp 459.11 lbf ≔Ev =⋅⋅0.2 SDS Wp 136.03 lbf Global Forces: ≔P =+⋅-0.9 Wp Ev -458.87 lbf ≔M =⋅EH hc 18364.56 ⋅in lbf ≔MΩ =⋅EHΩ hc 27546.84 ⋅in lbf Anchorage Forces - No Overstrenght Factor: ≔Flong =⋅―――⋅EH hc ⋅nB L ⎛ ⎜ ⎝ +1 ――⋅2 ey B ⎞ ⎟ ⎠ 630.52 lbf ≔Ftrans =⋅―――⋅EH hc ⋅nL B ⎛ ⎜ ⎝ +1 ――⋅2 ex L ⎞ ⎟ ⎠ 912.48 lbf ≔Vlong =⋅――EH n ⎛ ⎜ ⎝ +1 ――⋅2 ey B ⎞ ⎟ ⎠ 76.52 lbf ≔Vtrans =⋅――EH n ⎛ ⎜ ⎝ +1 ――⋅2 ex L ⎞ ⎟ ⎠ 76.52 lbf Tension due to 100% load about longitudinal axis plus 30% load about the transverse axis. This force governs for anchor design ≔T = ⎛ ⎜ ⎝ -+max ⎛⎝,Flong Ftrans⎞⎠⋅0.3 min ⎛⎝,Flong Ftrans⎞⎠――――― ⎛⎝-⋅0.9 Wp Ev⎞⎠ n ⎞ ⎟ ⎠ 986.92 lbf ≔V =‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾+max ⎛⎝,Vlong Vtrans⎞⎠ 2 ⎛⎝⋅0.3 min ⎛⎝,Vlong Vtrans⎞⎠⎞⎠2 79.89 lbf Anchorage Forces - With Overstrenght Factor: ≔ΩFlong =⋅―――⋅EHΩ hc ⋅nB L ⎛ ⎜ ⎝ +1 ――⋅2 ey B ⎞ ⎟ ⎠ 945.78 lbf ≔ΩFtrans =⋅―――⋅EHΩ hc ⋅nL B ⎛ ⎜ ⎝ +1 ――⋅2 ex L ⎞ ⎟ ⎠ 1368.72 lbf ≔ΩVlong =⋅――EHΩ n ⎛ ⎜ ⎝ +1 ――⋅2 ey B ⎞ ⎟ ⎠ 114.78 lbf ≔ΩVtrans =⋅――EHΩ n ⎛ ⎜ ⎝ +1 ――⋅2 ex L ⎞ ⎟ ⎠ 114.78 lbf ≔TΩ = ⎛ ⎜ ⎝ -+max ⎛⎝,ΩFlong ΩFtrans⎞⎠⋅0.3 min ⎛⎝,ΩFlong ΩFtrans⎞⎠――――― ⎛⎝-⋅0.9 Wp Ev⎞⎠ n ⎞ ⎟ ⎠ 1537.74 lbf ≔VΩ =‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾+max ⎛⎝,ΩVlong ΩVtrans⎞⎠ 2 ⎛⎝⋅0.3 min ⎛⎝,ΩVlong ΩVtrans⎞⎠⎞⎠2 119.83 lbf * See following pages for Hilti Calcs 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-8 YSI MAX WALL STAND Page: Specifier: E-Mail: Date: 1 3/4/2024 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - CS 5/8 (2 3/4) hnom1 Item number: 2210270 KB-TZ2 5/8x4 1/4 Effective embedment depth: hef,act = 2.750 in., hnom = 3.250 in. Material: Carbon Steel Evaluation Service Report: ESR-4266 Issued I Valid: 12/17/2021 | 12/1/2023 Proof: Design Method ACI 318-19 / Mech Stand-off installation: Profile: Base material: cracked concrete, 4000, fc' = 4,000 psi; h = 5.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Geometry [in.] & Loading [lb, in.lb] 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-8 YSI MAX WALL STAND Page: Specifier: E-Mail: Date: 2 3/4/2024 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 1,538; Vx = 0; Vy = 120; Mx = 0; My = 0; Mz = 0; no 40 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 1,538 120 0 120 max. concrete compressive strain: - [‰] max. concrete compressive stress: - [psi] resulting tension force in (x/y)=(0.000/0.000): 0 [lb] resulting compression force in (x/y)=(0.000/0.000): 0 [lb] 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*1,538 13,157 12 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**1,538 3,937 40 OK * highest loaded anchor **anchor group (anchors in tension) 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-8 YSI MAX WALL STAND Page: Specifier: E-Mail: Date: 3 3/4/2024 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4266 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.16 106,704 Calculations Nsa [lb] 17,542 Results Nsa [lb]f steel f Nsa [lb]Nua [lb] 17,542 0.750 13,157 1,538 3.2 Concrete Breakout Failure Ncb = (ANc ANc0)y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1a) f Ncb ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ca,min [in.]y c,N cac [in.]kc l a f' c [psi] 2.750 ∞1.000 10.000 21 1.000 4,000 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 68.06 68.06 1.000 1.000 6,057 Results Ncb [lb]f concrete f Ncb [lb]Nua [lb] 6,057 0.650 3,937 1,538 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-8 YSI MAX WALL STAND Page: Specifier: E-Mail: Date: 4 3/4/2024 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*120 6,668 2 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**120 8,480 2 OK Concrete edge failure in direction **N/A N/A N/A N/A * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa = ESR value refer to ICC-ES ESR-4266 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi] 0.16 106,704 Calculations Vsa [lb] 10,259 Results Vsa [lb]f steel f Vsa [lb]Vua [lb] 10,259 0.650 6,668 120 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-8 YSI MAX WALL STAND Page: Specifier: E-Mail: Date: 5 3/4/2024 4.2 Pryout Strength Vcp = kcp [(ANc ANc0)y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1a) f Vcp ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ca,min [in.]y c,N 2 2.750 ∞1.000 cac [in.]kc l a f' c [psi] 10.000 21 1.000 4,000 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 68.06 68.06 1.000 1.000 6,057 Results Vcp [lb]f concrete f Vcp [lb]Vua [lb] 12,114 0.700 8,480 120 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.391 0.018 5/3 22 OK bNV = bz N + bz V <= 1 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-8 YSI MAX WALL STAND Page: Specifier: E-Mail: Date: 6 3/4/2024 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-8 YSI MAX WALL STAND Page: Specifier: E-Mail: Date: 7 3/4/2024 7 Installation data Anchor type and diameter: Kwik Bolt TZ2 - CS 5/8 (2 3/4) hnom1 Profile: - Item number: 2210270 KB-TZ2 5/8x4 1/4 Hole diameter in the fixture: - Maximum installation torque: 481 in.lb Plate thickness (input): - Hole diameter in the base material: 0.625 in. Hole depth in the base material: 3.750 in. Drilling method: Hammer drilled Minimum thickness of the base material: 5.000 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti KB-TZ2 stud anchor with 3.25 in embedment, 5/8 (2 3/4) hnom1, Carbon steel, installation per ESR-4266 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool • Torque wrench • Hammer Coordinates Anchor in. Anchor x y c-x c+x c-y c+y 1 0.000 0.000 ---- 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-8 YSI MAX WALL STAND Page: Specifier: E-Mail: Date: 8 3/4/2024 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 1900 E 4th St - 1011190678/9/2024 WALTER P MOORE STRUCTURAL CALCULATIONS 1.02 - RAUN 216-5 - YSI TABLE DETAIL 11/S5-01 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- RAUN 216-5 YSI TABLE (DETAIL 11/S5-01) Operating Weight (including 400 lb patient) ≔Wp 1235 lbf Seismic Parameters ≔SDS 1.029 ≔Ip 1.5 ≔Ωo 1.5 FLOOR ATTACHMENT - MECHANICAL & ELECTRICAL ≔z 0 Component point of attachment elevation with respect to the base ≔h 1 Supporting structure average roof height relative to the base ≔z_h_ratio =―z h 0 ATTACHMENT IS AT 1st FLOOR ≔Fpmax =⋅⋅1.6 SDS Ip 2.47 ≔Fpmin =⋅⋅0.3 SDS Ip 0.463 ≔ap 1.0 ≔Rp 1.5 PATIENT TABLES SEISMIC PARAMETERS AS PER OSP-280 ≔Fp =⋅―――――⋅⋅0.4 ap SDS ――Rp Ip ((+1 ⋅2 z_h_ratio))0.412 ≔Fp =if else if else >Fpmin Fp ‖ ‖‖Fpmin <Fpmax Fp ‖ ‖‖Fpmax ‖ ‖‖Fp 0.463 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- CALCULATE MOMENT AT BASE ANCHORAGE Equipment Geometry: ≔L 26.375 in ≔B 10.625 in ≔H 37.5 in (Lenght) (Front of cab.) (Width) (Depth of cab.) (Height) ≔hc =H 37.5 in Location of centroid along height of cabinet. Excentricity from centroid along Length, L. "ex" is to the left edge , "ey" is to the right edge≔ex 0 in ≔ey ⋅0 in ≔nL 2 ≔nB 2 ≔n =⋅nL nB 4 Number of anchors along L and B. ≔EH =⋅Fp Wp 571.87 lbf ≔EHΩ =⋅⋅Ωo Fp Wp 857.8 lbf ≔Ev =⋅⋅0.2 SDS Wp 254.16 lbf Global Forces: ≔P =+⋅-0.9 Wp Ev -857.34 lbf ≔M =⋅EH hc 21445 ⋅in lbf ≔MΩ =⋅EHΩ hc 32167.5 ⋅in lbf Anchorage Forces - No Overstrenght Factor: ≔Flong =⋅―――⋅EH hc ⋅nB L ⎛ ⎜ ⎝ +1 ――⋅2 ey B ⎞ ⎟ ⎠ 406.54 lbf ≔Ftrans =⋅―――⋅EH hc ⋅nL B ⎛ ⎜ ⎝ +1 ――⋅2 ex L ⎞ ⎟ ⎠ 1009.18 lbf ≔Vlong =⋅――EH n ⎛ ⎜ ⎝ +1 ――⋅2 ey B ⎞ ⎟ ⎠ 142.97 lbf ≔Vtrans =⋅――EH n ⎛ ⎜ ⎝ +1 ――⋅2 ex L ⎞ ⎟ ⎠ 142.97 lbf Tension due to 100% load about longitudinal axis plus 30% load about the transverse axis. This force governs for anchor design ≔T = ⎛ ⎜ ⎝ -+max ⎛⎝,Flong Ftrans⎞⎠⋅0.3 min ⎛⎝,Flong Ftrans⎞⎠――――― ⎛⎝-⋅0.9 Wp Ev⎞⎠ n ⎞ ⎟ ⎠ 916.8 lbf ≔V =‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾+max ⎛⎝,Vlong Vtrans⎞⎠ 2 ⎛⎝⋅0.3 min ⎛⎝,Vlong Vtrans⎞⎠⎞⎠2 149.26 lbf Anchorage Forces - With Overstrenght Factor: ≔ΩFlong =⋅―――⋅EHΩ hc ⋅nB L ⎛ ⎜ ⎝ +1 ――⋅2 ey B ⎞ ⎟ ⎠ 609.81 lbf ≔ΩFtrans =⋅―――⋅EHΩ hc ⋅nL B ⎛ ⎜ ⎝ +1 ――⋅2 ex L ⎞ ⎟ ⎠ 1513.76 lbf ≔ΩVlong =⋅――EHΩ n ⎛ ⎜ ⎝ +1 ――⋅2 ey B ⎞ ⎟ ⎠ 214.45 lbf ≔ΩVtrans =⋅――EHΩ n ⎛ ⎜ ⎝ +1 ――⋅2 ex L ⎞ ⎟ ⎠ 214.45 lbf ≔TΩ = ⎛ ⎜ ⎝ -+max ⎛⎝,ΩFlong ΩFtrans⎞⎠⋅0.3 min ⎛⎝,ΩFlong ΩFtrans⎞⎠――――― ⎛⎝-⋅0.9 Wp Ev⎞⎠ n ⎞ ⎟ ⎠ 1482.37 lbf ≔VΩ =‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾+max ⎛⎝,ΩVlong ΩVtrans⎞⎠ 2 ⎛⎝⋅0.3 min ⎛⎝,ΩVlong ΩVtrans⎞⎠⎞⎠2 223.89 lbf * See following pages for Hilti Calcs 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-5 YSI TABLE Page: Specifier: E-Mail: Date: 1 3/4/2024 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - CS 5/8 (2 3/4) hnom1 Item number: 2210270 KB-TZ2 5/8x4 1/4 Effective embedment depth: hef,act = 2.750 in., hnom = 3.250 in. Material: Carbon Steel Evaluation Service Report: ESR-4266 Issued I Valid: 12/17/2021 | 12/1/2023 Proof: Design Method ACI 318-19 / Mech Stand-off installation: Profile: Base material: cracked concrete, 4000, fc' = 4,000 psi; h = 5.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Geometry [in.] & Loading [lb, in.lb] 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-5 YSI TABLE Page: Specifier: E-Mail: Date: 2 3/4/2024 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 1,482; Vx = 0; Vy = 224; Mx = 0; My = 0; Mz = 0; no 38 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 1,482 224 0 224 max. concrete compressive strain: - [‰] max. concrete compressive stress: - [psi] resulting tension force in (x/y)=(0.000/0.000): 0 [lb] resulting compression force in (x/y)=(0.000/0.000): 0 [lb] 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*1,482 13,157 12 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**1,482 3,937 38 OK * highest loaded anchor **anchor group (anchors in tension) 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-5 YSI TABLE Page: Specifier: E-Mail: Date: 3 3/4/2024 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4266 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.16 106,704 Calculations Nsa [lb] 17,542 Results Nsa [lb]f steel f Nsa [lb]Nua [lb] 17,542 0.750 13,157 1,482 3.2 Concrete Breakout Failure Ncb = (ANc ANc0)y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1a) f Ncb ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ca,min [in.]y c,N cac [in.]kc l a f' c [psi] 2.750 ∞1.000 10.000 21 1.000 4,000 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 68.06 68.06 1.000 1.000 6,057 Results Ncb [lb]f concrete f Ncb [lb]Nua [lb] 6,057 0.650 3,937 1,482 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-5 YSI TABLE Page: Specifier: E-Mail: Date: 4 3/4/2024 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*224 6,668 4 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**224 8,480 3 OK Concrete edge failure in direction **N/A N/A N/A N/A * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa = ESR value refer to ICC-ES ESR-4266 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi] 0.16 106,704 Calculations Vsa [lb] 10,259 Results Vsa [lb]f steel f Vsa [lb]Vua [lb] 10,259 0.650 6,668 224 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-5 YSI TABLE Page: Specifier: E-Mail: Date: 5 3/4/2024 4.2 Pryout Strength Vcp = kcp [(ANc ANc0)y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1a) f Vcp ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ca,min [in.]y c,N 2 2.750 ∞1.000 cac [in.]kc l a f' c [psi] 10.000 21 1.000 4,000 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 68.06 68.06 1.000 1.000 6,057 Results Vcp [lb]f concrete f Vcp [lb]Vua [lb] 12,114 0.700 8,480 224 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.376 0.034 5/3 20 OK bNV = bz N + bz V <= 1 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-5 YSI TABLE Page: Specifier: E-Mail: Date: 6 3/4/2024 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-5 YSI TABLE Page: Specifier: E-Mail: Date: 7 3/4/2024 7 Installation data Anchor type and diameter: Kwik Bolt TZ2 - CS 5/8 (2 3/4) hnom1 Profile: - Item number: 2210270 KB-TZ2 5/8x4 1/4 Hole diameter in the fixture: - Maximum installation torque: 481 in.lb Plate thickness (input): - Hole diameter in the base material: 0.625 in. Hole depth in the base material: 3.750 in. Drilling method: Hammer drilled Minimum thickness of the base material: 5.000 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti KB-TZ2 stud anchor with 3.25 in embedment, 5/8 (2 3/4) hnom1, Carbon steel, installation per ESR-4266 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool • Torque wrench • Hammer Coordinates Anchor in. Anchor x y c-x c+x c-y c+y 1 0.000 0.000 ---- 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-5 YSI TABLE Page: Specifier: E-Mail: Date: 8 3/4/2024 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 1900 E 4th St - 1011190678/9/2024 WALTER P MOORE STRUCTURAL CALCULATIONS 1.03 - RAUN 216-6 POLYDOROS R80 (80KW) GENERATOR CABINET DETAIL 16/S5-01 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- RAUN 216-6 POLYDOROS R80 (80KW) GENERATOR CABINET (DETAIL 16/S5-01) Operating Weight ≔Wp 883 lbf Seismic Parameter ≔SDS 1.029 ≔Ip 1.0 ≔Ωo 2.0 FLOOR ATTACHMENT - CABINETS ≔z 0 Component point of attachment elevation with respect to the base ≔h 1 Supporting structure average roof height relative to the base ≔z_h_ratio =―z h 0 ATTACHMENT IS AT 1ST LEVEL ≔Fpmax =⋅⋅1.6 SDS Ip 1.646 ≔Fpmin =⋅⋅0.3 SDS Ip 0.309 ≔ap 2.5 ≔Rp 6.0 SEISMIC PARAMETERS AS PER OSP-280 ≔Fp =⋅―――――⋅⋅0.4 ap SDS ――Rp Ip ((+1 ⋅2 z_h_ratio))0.172 ≔Fp =if else if else >Fpmin Fp ‖ ‖‖Fpmin <Fpmax Fp ‖ ‖‖Fpmax ‖ ‖‖Fp 0.309 (E) 4" thick 3000psi concrete slab 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- CALCULATE MOMENT AT BASE ANCHORAGE Equipment Geometry: ≔L 31.5 in ≔B 17.125 in ≔H 88 in (Lenght) (Front of cab.) (Width) (Depth of cab.) (Height) ≔hc =43.5 in 43.5 in Location of centroid along height of cabinet. Excentricity from centroid along Length, L. "ex" is to the left edge , "ey" is to the right edge. ≔ex ⋅0 in ≔ey ⋅0 in ≔nL 2 ≔nB 2 ≔n =⋅nL nB 4 Number of anchors along L and B. ≔EH =⋅Fp Wp 272.58 lbf ≔EHΩ =⋅⋅Ωo Fp Wp 545.16 lbf ≔Ev =⋅⋅0.2 SDS Wp 181.72 lbf Global Forces: ≔P =+⋅-0.9 Wp Ev -612.98 lbf ≔M =⋅EH hc 11857.32 ⋅in lbf ≔MΩ =⋅EHΩ hc 23714.64 ⋅in lbf Equipment is anchored at the base and at the top to the wall. Due to top connection, there is no overturning tension at the base anchors. When the seismic load is perpendicular to the wall the base anchors are in shear and the wall anchors are in tension. When the seismic load is parallel to the wall the base anchors are in shear and the wall anchors are also in shear. Refer to the following calculations for anchor forces. Loads at Base- Seismic Load Perpendicular to wall ≔F_total = ⎛ ⎜ ⎝ ――EH 2 ⎞ ⎟ ⎠ 136.291 lbf Horizontal load at base. Load is distributed equally to top and bottom. ≔Vomega_tot =⋅Ωo ⎛⎝F_total⎞⎠272.582 lbf Shear load at base including omega for anchors into concrete. ≔Vomega_anch =――――Vomega_tot 2 136.291 lbf Omega shear load at base divided by 2 anchors into concrete. Loads at Base - Seismic Load Parallel to wall. See Hilti calculation for anchorage into concrete. Loads at Top- Seismic Load Perpendicular to wall ≔F_total = ⎛ ⎜ ⎝ ――EH 2 ⎞ ⎟ ⎠ 136.291 lbf (2) Brackets with 3 screws each, 6 screws in total. ≔Nscrew 6 ≔Tscrew =―――F_total Nscrew 22.715 lbf ≔Rnt 109 lbf Pull out capacity (#10 SMS 43 mil). See available screw capacity table below. ≔DCRT =―――Tscrew Rnt 0.208 Screw tension capacity >> demand, Design Acceptable 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- RAUN 216-6: Connection at the Top 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- Check CFMF Vertical Stud Capacity Vertical Stud Elevation View: ≔L 16.0 ft Floor height ≔Z =H 88 in Assume worst case, H is height of equipment ≔P =F_total 136.291 lbf Load applied to CFMF stud (assume top connection is aligned with single vertical stud) ≔Moment_Max =―――――⋅⋅P Z ((-L Z)) L 6.497 ⋅kip in LRFD load level ≔Sxe 0.444 ((in))3 Section properties for 362S162-54 ≔Fy 50 ksi ≔Moment_Capacity =⋅⋅0.6 Sxe Fy 13.32 ⋅kip in ≔DCRF =―――――Moment_Max ⋅⋅17.18 kip in 0.378 Loads at Top - Seismic Load Parallel to wall ≔F_total = ⎛ ⎜ ⎝ ――EH 2 ⎞ ⎟ ⎠ 136.291 lbf (2) Brackets with 3 screws each, 6 screws in total. ≔Nscrew 6 ≔Vscrew =―――F_total Nscrew 22.715 lbf ≔Rns 263 lbf Shear capacity (#10 SMS 43 mil). See available screw capacity table below. ≔DCRT =―――Tscrew Rnt 0.208 Screw shear capacity >> demand, Design Acceptable 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-6 POLYDOROS R80 GEN CABINET Page: Specifier: E-Mail: Date: 1 3/11/2024 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - CS 3/8 (1 1/2) hnom1 Item number: 2210234 KB-TZ2 3/8x2 1/2 Effective embedment depth: hef,act = 1.500 in., hnom = 1.875 in. Material: Carbon Steel Evaluation Service Report: ESR-4266 Issued I Valid: 12/17/2021 | 12/1/2023 Proof: Design Method ACI 318-19 / Mech Stand-off installation: Profile: Base material: cracked concrete, 3000, fc' = 3,000 psi; h = 4.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Geometry [in.] & Loading [lb, in.lb] 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-6 POLYDOROS R80 GEN CABINET Page: Specifier: E-Mail: Date: 2 3/11/2024 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 0; Vx = 0; Vy = 137; Mx = 0; My = 0; Mz = 0; no 10 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 0 137 0 137 max. concrete compressive strain: - [‰] max. concrete compressive stress: - [psi] resulting tension force in (x/y)=(0.000/0.000): 0 [lb] resulting compression force in (x/y)=(0.000/0.000): 0 [lb] 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*N/A N/A N/A N/A Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**N/A N/A N/A N/A * highest loaded anchor **anchor group (anchors in tension) 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-6 POLYDOROS R80 GEN CABINET Page: Specifier: E-Mail: Date: 3 3/11/2024 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*137 2,097 7 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**137 1,479 10 OK Concrete edge failure in direction **N/A N/A N/A N/A * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa = ESR value refer to ICC-ES ESR-4266 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi] 0.05 126,204 Calculations Vsa [lb] 3,226 Results Vsa [lb]f steel f Vsa [lb]Vua [lb] 3,226 0.650 2,097 137 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-6 POLYDOROS R80 GEN CABINET Page: Specifier: E-Mail: Date: 4 3/11/2024 4.2 Pryout Strength Vcp = kcp [(ANc ANc0)y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1a) f Vcp ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ca,min [in.]y c,N 1 1.500 ∞1.000 cac [in.]kc l a f' c [psi] 5.000 21 1.000 3,000 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 20.25 20.25 1.000 1.000 2,113 Results Vcp [lb]f concrete f Vcp [lb]Vua [lb] 2,113 0.700 1,479 137 5 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-6 POLYDOROS R80 GEN CABINET Page: Specifier: E-Mail: Date: 5 3/11/2024 6 Installation data Anchor type and diameter: Kwik Bolt TZ2 - CS 3/8 (1 1/2) hnom1 Profile: - Item number: 2210234 KB-TZ2 3/8x2 1/2 Hole diameter in the fixture: - Maximum installation torque: 361 in.lb Plate thickness (input): - Hole diameter in the base material: 0.375 in. Hole depth in the base material: 2.000 in. Drilling method: Hammer drilled Minimum thickness of the base material: 3.250 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti KB-TZ2 stud anchor with 1.875 in embedment, 3/8 (1 1/2) hnom1, Carbon steel, installation per ESR-4266 6.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool • Torque wrench • Hammer Coordinates Anchor in. Anchor x y c-x c+x c-y c+y 1 0.000 0.000 ---- 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: | RAUN 216-6 POLYDOROS R80 GEN CABINET Page: Specifier: E-Mail: Date: 6 3/11/2024 7 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 1900 E 4th St - 1011190678/9/2024 WALTER P MOORE STRUCTURAL CALCULATIONS 1.04 - RAUN 216-11 - GRID HOLDER CABINET DETAIL 02/S5-01 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- RAUN 216-11 GRID HOLDER CABINET (DETAIL 02/S5-01) Operating Weight ≔Wp 22 lbf Seismic Parameter ≔SDS 1.029 ≔Ip 1.0 ≔Ωo 2.0 FLOOR ATTACHMENT - CABINETS ≔z 0 Component point of attachment elevation with respect to the base ≔h 289.5 Supporting structure average roof height relative to the base ≔z_h_ratio =―z h 0 ATTACHMENT IS AT 1ST LEVEL ≔Fpmax =⋅⋅1.6 SDS Ip 1.646 ≔Fpmin =⋅⋅0.3 SDS Ip 0.309 ≔ap 2.5 ≔Rp 6.0 SEISMIC PARAMETERS AS PER OSP-280 ≔Fp =⋅―――――⋅⋅0.4 ap SDS ――Rp Ip ((+1 ⋅2 z_h_ratio))0.172 ≔Fp =if else if else >Fpmin Fp ‖ ‖‖Fpmin <Fpmax Fp ‖ ‖‖Fpmax ‖ ‖‖Fp 0.309 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- CALCULATE MOMENT AT WALL ANCHORAGE Equipment Geometry: ≔L 12.8 in ≔B 14.0 in (Lenght) (Width) (Depth of cab.) ≔hc 6 in Location of centroid along height of cabinet. Location of centroid along Length, L. "ex" is to the left edge , "ey" is to the right edge. ≔ex ⋅0 in ≔ey ⋅0 in ≔nL 1 ≔nB 2 ≔n =⋅nL nB 2 Number of anchor points along L and B. ≔fD 1.2 ≔fEv 1.0 ≔fEh 1.0 ≔EH =⋅Fp Wp 6.79 lbf ≔EHΩ =⋅⋅Ωo Fp Wp 13.58 lbf ≔Ev =⋅⋅0.2 SDS Wp 4.53 lbf Global Forces: ≔P =+⋅fD Wp ⋅fEv Ev 30.93 lbf ≔Mp =⋅P hc 185.57 ⋅in lbf ≔M =⋅⎛⎝⋅fEh EH⎞⎠hc 40.75 ⋅in lbf ≔H =⋅fEh EH 6.79 lbf ≔MΩ =⋅⎛⎝⋅fEh EHΩ⎞⎠hc 81.5 ⋅in lbf ≔HΩ =⋅fEh EHΩ 13.58 lbf Anchorage Forces - No Overstrenght Factor: ≔θ ⋅23 deg Max T at θ ≔T =max ⎛ ⎜ ⎜⎝ ++⋅――⋅P hc ⋅L nB ⎛ ⎜⎝+1 ――⋅2 ex B ⎞ ⎟⎠⋅⋅――――⋅H cos ((θ)) n ⎛ ⎜⎝+1 ――⋅2 ex B ⎞ ⎟⎠ ⎛ ⎜⎝+1 ――⋅2 ey L ⎞ ⎟⎠⋅――――⋅M sin ((θ)) ⋅B nL ⎛ ⎜⎝+1 ――⋅2 ey L ⎞ ⎟⎠ ⎞ ⎟ ⎟⎠ 11.51 lbf ≔V =――――――――――――― ‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾ + ⎛ ⎜ ⎝ ⋅P ⎛ ⎜ ⎝ +1 ――⋅2 ex B ⎞ ⎟ ⎠ ⎞ ⎟ ⎠ 2 ⎛ ⎜ ⎝ ⋅H ⎛ ⎜ ⎝ +1 ――⋅2 ey L ⎞ ⎟ ⎠ ⎞ ⎟ ⎠ 2 n 15.83 lbf Anchorage Forces - With Overstrenght Factor: ≔θ ⋅23 deg Max T at θ ≔TΩ =max ⎛ ⎜ ⎜⎝ ++⋅――⋅P hc ⋅L nB ⎛ ⎜⎝+1 ――⋅2 ex B ⎞ ⎟⎠⋅⋅――――⋅HΩ cos ((θ)) n ⎛ ⎜⎝+1 ――⋅2 ex B ⎞ ⎟⎠ ⎛ ⎜⎝+1 ――⋅2 ey L ⎞ ⎟⎠⋅――――⋅MΩ sin ((θ)) ⋅B nL ⎛ ⎜⎝+1 ――⋅2 ey L ⎞ ⎟⎠ ⎞ ⎟ ⎟⎠ 15.77 lbf ≔VΩ =――――――――――――― ‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾ + ⎛ ⎜ ⎝ ⋅P ⎛ ⎜ ⎝ +1 ――⋅2 ex B ⎞ ⎟ ⎠ ⎞ ⎟ ⎠ 2 ⎛ ⎜ ⎝ ⋅HΩ ⎛ ⎜ ⎝ +1 ――⋅2 ey L ⎞ ⎟ ⎠ ⎞ ⎟ ⎠ 2 n 16.89 lbf 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- CFMF 362S162-68 backing, 362S162-68 studs, and 1/4" SMS screws have sufficient capacity to withstand tension and shear forces, see below. ≔Tmax_per_screw =――TΩ 1 15.775 lbf ≔Vmax_per_screw =――VΩ 1 75.128 N Screw Check. ≔DCRshear =―――――Vmax_per_screw 302 lbf 0.06 1/4" 18 Gage (43 Mils) ≔DCRtension =―――――Tmax_per_screw 144 lbf 0.11 362S162-68 Check. ≔DCRshear =―――――Vmax_per_screw 662 lbf 0.03 1900 E 4th St - 1011190678/9/2024 WALTER P MOORE STRUCTURAL CALCULATIONS 1.05 - PARTIAL HEIGHT WALL DETAIL 19/S5-01 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- PARTIAL HEIGHT WALL (DETAIL 19/S5-01) Operating Weight ≔Wp 12 psf *Typical partition wall weight Post spacing≔swall 3 ft ≔hwall 7 ft Max wall height Seismic Parameter ≔SDS 1.029 ≔Ip 1.5 FLOOR ATTACHMENT - WALLS AND PARTITIONS ≔z 0 Component point of attachment elevation with respect to the base ≔h 289.5 Supporting structure average roof height relative to the base ≔z_h_ratio =―z h 0 ATTACHMENT IS AT 1ST LEVEL ≔Fpmax =⋅⋅1.6 SDS Ip 2.47 ≔Fpmin =⋅⋅0.3 SDS Ip 0.463 ≔ap 1.0 ≔Rp 2.5 ≔Ωo 2.0 INTERIOR NON STRUCTURAL WALLS AND PARTITIONS SEISMIC PARAMETERS AS PER ASCE 7-16 ≔fp =⋅――――⋅⋅0.4 ap SDS ――Rp Ip ((+1 ⋅2 z_h_ratio))0.247 ≔fp =if else if else >Fpmin Fp ‖ ‖‖Fpmin <Fpmax Fp ‖ ‖‖Fpmax ‖ ‖‖Fp 0.463 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- ≔Fp =⋅fp Wp 5.557 psf Component seismic force ≔EH =⋅⋅Fp swall hwall 116.69 lbf Lateral load with Omega ≔EHΩ =⋅⋅⋅Ωo Fp swall hwall 233.38 lbf Lateral load with Omega ≔Ev =⋅⋅⋅⋅0.2 SDS Fp swall hwall 24.01 lbf Global Forces: ≔P =+⋅⋅⋅-0.9 Fp swall hwall Ev -81.01 lbf ≔M =⋅EH hc 700.13 ⋅in lbf Hil demands, see following pages for Hil calculaon report ≔MΩ =⋅EHΩ hc 1400.26 ⋅in lbf ≔VΩ =EHΩ 233.377 lbf 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | Partial wall- Base Anchor Page: Specifier: E-Mail: Date: 1 3/11/2024 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - CS 1/2 (2) hnom2 Item number: 2210254 KB-TZ2 1/2x3 3/4 Effective embedment depth: hef,act = 2.000 in., hnom = 2.500 in. Material: Carbon Steel Evaluation Service Report: ESR-4266 Issued I Valid: 12/17/2021 | 12/1/2023 Proof: Design Method ACI 318-19 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plateR : lx x ly x t = 4.000 in. x 9.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) Profile: Square HSS (AISC), HSS3X3X.375; (L x W x T) = 3.000 in. x 3.000 in. x 0.375 in. Base material: cracked concrete, 3000, fc' = 3,000 psi; h = 4.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, in.lb] 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | Partial wall- Base Anchor Page: Specifier: E-Mail: Date: 2 3/11/2024 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 0; Vx = 0; Vy = 234; Mx = 1,401; My = 0; Mz = 0; no 10 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 2 117 0 117 2 199 117 0 117 max. concrete compressive strain: 0.02 [‰] max. concrete compressive stress: 71 [psi] resulting tension force in (x/y)=(0.000/0.000): 0 [lb] resulting compression force in (x/y)=(2.000/0.475): 202 [lb] Anchor forces are calculated based on the assumption of a rigid anchor plate. 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*199 8,433 3 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**202 2,141 10 OK * highest loaded anchor **anchor group (anchors in tension) 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | Partial wall- Base Anchor Page: Specifier: E-Mail: Date: 3 3/11/2024 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4266 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.10 114,004 Calculations Nsa [lb] 11,244 Results Nsa [lb]f steel f Nsa [lb]Nua [lb] 11,244 0.750 8,433 199 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | Partial wall- Base Anchor Page: Specifier: E-Mail: Date: 4 3/11/2024 3.2 Concrete Breakout Failure Ncbg = (ANc ANc0)y ec,N y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1b) f Ncbg ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ec,N = (1 1 + 2 e' N 3 hef )£ 1.0 ACI 318-19 Eq. (17.6.2.3.1) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ec1,N [in.]ec2,N [in.]ca,min [in.]y c,N 2.000 0.000 2.927 ∞1.000 cac [in.]kc l a f' c [psi] 5.500 21 1.000 3,000 Calculations ANc [in.2]ANc0 [in.2]y ec1,N y ec2,N y ed,N y cp,N Nb [lb] 72.00 36.00 1.000 0.506 1.000 1.000 3,253 Results Ncbg [lb]f concrete f Ncbg [lb]Nua [lb] 3,294 0.650 2,141 202 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: | Partial wall- Base Anchor Page: Specifier: E-Mail: Date: 5 3/11/2024 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*117 3,599 4 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**234 4,555 6 OK Concrete edge failure in direction **N/A N/A N/A N/A * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa = ESR value refer to ICC-ES ESR-4266 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi] 0.10 114,004 Calculations Vsa [lb] 5,537 Results Vsa [lb]f steel f Vsa [lb]Vua [lb] 5,537 0.650 3,599 117 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: | Partial wall- Base Anchor Page: Specifier: E-Mail: Date: 6 3/11/2024 4.2 Pryout Strength Vcpg = kcp [(ANc ANc0)y ec,N y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1b) f Vcpg ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ec,N = (1 1 + 2 e' N 3 hef )£ 1.0 ACI 318-19 Eq. (17.6.2.3.1) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ec1,N [in.]ec2,N [in.]ca,min [in.] 1 2.000 0.000 0.000 ∞ y c,N cac [in.]kc l a f' c [psi] 1.000 5.500 21 1.000 3,000 Calculations ANc [in.2]ANc0 [in.2]y ec1,N y ec2,N y ed,N y cp,N Nb [lb] 72.00 36.00 1.000 1.000 1.000 1.000 3,253 Results Vcpg [lb]f concrete f Vcpg [lb]Vua [lb] 6,507 0.700 4,555 234 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.094 0.051 5/3 3 OK bNV = bz N + bz V <= 1 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: | Partial wall- Base Anchor Page: Specifier: E-Mail: Date: 7 3/11/2024 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.91 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Company: Address: Phone I Fax: Design: Fastening point: | Partial wall- Base Anchor Page: Specifier: E-Mail: Date: 8 3/11/2024 Coordinates Anchor [in.] Anchor x y c-x c+x c-y c+y 1 0.000 -3.000 ---- 2 0.000 3.000 ---- 7 Installation data Anchor type and diameter: Kwik Bolt TZ2 - CS 1/2 (2) hnom2 Profile: Square HSS (AISC), HSS3X3X.375; (L x W x T) = 3.000 in. x 3.000 in. x 0.375 in. Item number: 2210254 KB-TZ2 1/2x3 3/4 Hole diameter in the fixture: df = 0.562 in. Maximum installation torque: 602 in.lb Plate thickness (input): 0.500 in. Hole diameter in the base material: 0.500 in. Recommended plate thickness: not calculated Hole depth in the base material: 2.750 in. Drilling method: Hammer drilled Minimum thickness of the base material: 4.000 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti KB-TZ2 stud anchor with 2.5 in embedment, 1/2 (2) hnom2, Carbon steel, installation per ESR-4266 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool • Torque wrench • Hammer 1900 E 4th St - 1011190678/9/2024 WALTER P MOORE STRUCTURAL CALCULATIONS 2.00 - Equipment at ceiling 1900 E 4th St - 1011190678/9/2024 WALTER P MOORE STRUCTURAL CALCULATIONS 2.01 - RAUN 216-10 Analysis of ceiling structure Detail 01/S5-02 1900 E 4th St - 1011190678/9/2024 job name job no. date engineer dwg. ref tab no. sheet no. e n g i n e e r The following is a summary of the analysis performed to generate member forces and reactions for the ceiling supported RAUN 216-9 and RAUN 216-10 RSL equipment. SAP2000 V21 software was used. All loads including structure self weight, eccentricities and seismic loads are applied. Main rails Green lines locate RAUN 216-09 track Red lines locate RAUN 216-10 track 1900 E 4th St - 1011190678/9/2024 job name job no. date engineer dwg. ref tab no. sheet no. e n g i n e e r Detail 13 on S5-01 to indicate load path. 1900 E 4th St - 1011190678/9/2024 job name job no. date engineer dwg. ref tab no. sheet no. e n g i n e e r SAP 2000 Geometry: HSS columns shown in yellow HSS framing shown in red Main Rails shown in gray Stubs Connecting Rails shown in cyan Manufacturer Equipment and eccentricity modeled through rigid frame elements Manufacturer Rails shown in green SAP 2000 Releases: HSS framing Pin released each end Main Rails Continuous Stubs Between Rails pin-release to release torsion and we axis bending Manufacturer Rails pin-released between sub rails to remove restraint and not relied on to contribute to strength/stiffness Manufacturer Equipment pin-released where it attaches to manufacturer rails 1900 E 4th St - 1011190678/9/2024 job name job no. date engineer dwg. ref tab no. sheet no. e n g i n e e r SAP 2000 Loads: Unistrut frame members and material modeled so the weight matches the unistrut catalog. Members length modeled exactly. CAS 820-B equipment weight: Weight of equipment at eccentric locations modeled directly in SAP 2000 1900 E 4th St - 1011190678/9/2024 job name job no. date engineer dwg. ref tab no. sheet no. e n g i n e e r SAP 2000 Loading Scenarios: There are 4 load scenarios created: 1a) Equipment located on the right centered between hangers. Equipment is eccentric in the 'Y' direction 1b) Equipment located on the right centered between hangers. Equipment is eccentric in the 'X' direction 2a) Equipment located centered above middle hangers. Equipment is eccentric in the 'Y' direction 2b) Equipment located centered above middle hangers. Equipment is eccentric in the 'X' direction Load condition 1a Load condition 2a Load condition 1b Load condition 2b 1900 E 4th St - 1011190678/9/2024 job name job no. date engineer dwg. ref tab no. sheet no. e n g i n e e r SAP 2000 Mass Source: RAUN 216-09: 846 LB (2) RAUN 216-10: 118 LB FRAMING: 3537.2 LB TOTAL: 4501.2 LB Expected Lateral Force Wp= (4501.2 LB)*(0.463)=2084.1 LB SAP 2000 Base Shear: 1900 E 4th St - 1011190678/9/2024 job name job no. date engineer dwg. ref tab no. sheet no. e n g i n e e r SAP 2000 Load Combinations: ASD load combinations created for design of the unistrut ceiling structure. LRFD load combinations with overstrenght factor applied to the seismic component created for the anchorage design of components in concrete (as required by ASCE7) Load combinations generated include gravity loads and seismic loads applied in increments of 45 degrees in all directions. Seismic loads at 45 degree increments are generated by adding components of the 'Ex' and 'Ey' force. *Note: Update snapshots as required 1900 E 4th St - 1011190678/9/2024 job name job no. date engineer dwg. ref tab no. sheet no. e n g i n e e r This is Chapter 13 seismic factor to be multiplied by the seismic weight (Wp) to generate the seismic force Seismic factor applied as an acceleration. 1g=386.09 in/s^2. Multiplying by 0.463 produces an acceleration of 178.76 in/s^2. As shown load case generated for both the X & Y directions. Seismic load applied at various angle is applied by use of load combinations. 1900 E 4th St - 1011190678/9/2024 job name job no. date engineer dwg. ref tab no. sheet no. e n g i n e e r Mass source includes element self weight plus superimposed dead load from equipment. 1900 E 4th St - 1011190678/9/2024 job name job no. date engineer dwg. ref tab no. sheet no. e n g i n e e r HSS framing element checks : Grille HSS 8X4X3/8 Columns HSS 5X5X3/8 1900 E 4th St - 1011190678/9/2024 job name job no. date engineer dwg. ref tab no. sheet no. e n g i n e e r Framing deflection check: *Inches 178i n Deflection limit L/1000 178in/1000=0.18in 1900 E 4th St - 1011190678/9/2024 job name job no. date engineer dwg. ref tab no. sheet no. e n g i n e e r Main Rail member forces: Maximum ASD Tension = 318.4 lbf Maximum ASD Compression = 343.3 lbf Maximum ASD Strong Axis Bending = 380.2 lb-ft Maximum ASD Weak Axis Bending = 86.4 lb-ft 1900 E 4th St - 1011190678/9/2024 job name job no. date engineer dwg. ref tab no. sheet no. e n g i n e e r Stub member between rails. Forces used for bolted connection design between stub and main rails Maximum ASD Tension = 702.2 lbf Maximum ASD Compression = 392.3 lbf Maximum ASD Shear 'X' direction = 344.5 lb Maximum ASD Shear 'Y' direction = 130.2 lb 1900 E 4th St - 1011190678/9/2024 job name job no. date engineer dwg. ref tab no. sheet no. e n g i n e e r Base Reactions at Concrete - LRFD with omega - Reactions used for concrete anchorage design Maximum LRFD Omega Compression = 2216.0 lbf Maximum LRFD Omega Shear X dir = 269.6 lbf Maximum LRFD Omega Shear Y dir = 257.8 lbf Maximum LRFD Shear X dir = 458.4.6 lbf Maximum LRFD Shear Y dir = 411.4 lbf *lbf Top Reactions at Concrete - LRFD with omega - Reactions used for concrete anchorage design *lbf 1900 E 4th St - 1011190678/9/2024 WALTER P MOORE STRUCTURAL CALCULATIONS 2.02 - RAUN 216-10 Design of ceiling structure Detail 01/S5-02 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- Seismic Parameter ≔SDS 1.029 ≔Ip 1.5 ≔Ωo 2.0 ≔z 0 Component point of attachment elevation with respect to the base ≔h 1 Supporting structure average roof height relative to the base ≔z_h_ratio =―z h 0 ATTACHMENT IS AT 3RD FLOOR ≔Fpmax =⋅⋅1.6 SDS Ip 2.47 ≔Fpmin =⋅⋅0.3 SDS Ip 0.463 ≔ap 1.0 ≔Rp 2.5 LAB EQUIPMENT PER ASCE 7-10 TABLE 13.5-1 ≔Fp =⋅――――― ⋅⋅0.4 ap SDS ―― Rp Ip ((+1 ⋅2 z_h_ratio))0.247 ≔Fp =if else if else >Fpmin Fp ‖ ‖‖Fpmin <Fpmax Fp ‖ ‖‖Fpmax ‖ ‖‖Fp 0.463 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- ≔Omega_bending 1.67 ≔Omega_axial 1.8 ≔Fy_uni 33 ksi ≔E_uni 29000 ksi 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- Main Rail Design (P1001) Design Loads Rail Design Tension: Rail Design Flexure (strong axis) ≔Ru_t 318.4 lbf ≔Mu_s ⋅380.2 lbf ft RailDesign Compression: Rail Design Flexure (weak axis) ≔Ru_c 343.3 lbf ≔Mu_w ⋅86.4 lbf ft Design Capacity Unistrut design properties: ≔A 1.111 in 2 ≔K 1 ≔L 4.0 ft ≔r_s ⋅0.914 in ≔r_w 0.651 in ≔S_s 0.571 in 3 ≔S_w 0.58 in 3 ≔Rn_t =―――――⋅A Fy_uni Omega_axial 20.368 kip Tension Capacity =if else >Rn_t Ru_t ‖ ‖“Design Acceptable” ‖ ‖“Failure” “Design Acceptable” ≔DCRT =――Ru_t Rn_t 0.016 ≔Rn_c =⋅――――⋅π 2 E_uni ⎛ ⎜⎝ ――⋅1 L r_s ⎞ ⎟⎠ 2 ―――――A Omega_axial 64.054 kip Compression Capacity =if else >Rn_c Ru_c ‖ ‖“Design Acceptable” ‖ ‖“Failure” “Design Acceptable” ≔DCRC =――Ru_c Rn_c 0.005 ≔Mn_s =――――――⋅Fy_uni S_s Omega_bending 940.269 ⋅lbf ft Bending Capacity - Strong Axis =if else >Mn_s Mu_s ‖ ‖“Design Acceptable” ‖ ‖“Failure” “Design Acceptable” ≔DCRBs =―――Mu_s Mn_s 0.404 ≔Mn_w =――――――⋅Fy_uni S_w Omega_bending 955.09 ⋅lbf ft Bending Capacity - Weak Axis =if else >Mn_w Mu_w ‖ ‖“Design Acceptable” ‖ ‖“Failure” “Design Acceptable” ≔DCRBw =―――Mu_w Mn_w 0.09 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- Connection Design P1937 Fitting - main rail to sub rail attachment Stub Design Loads: ≔Tu 702.2 lbf ≔Vx 344.5 lbf ≔Vy 130.2 lbf ≔t 0.25 in ≔w 1.86 in ≔Fy 33 ksi ≔Ωb 1.67 ≔Mn =⋅――⋅w t 2 4 ――Fy Ωb 0.574 ⋅kip in ≔lever_arm =――――――― ―――――――-5.375 in 1.656 in 2 2 0.93 in ≔Mu =⋅――Tu 2 lever_arm 0.326 ⋅kip in ≔Rn_t =―――――⋅A Fy_uni Omega_axial 20.368 kip =if else >Rn_t Tu ‖ ‖‖“Design Acceptable” ‖ ‖‖“Failure” “Design Acceptable” ≔DCRT =――Tu Rn_t 0.034 P2786 fitting ≔Tu 702.2 lbf Stubs force ≔Rn 1000 lbf =if else >Rn ――Tu 1 ‖ ‖“Design Acceptable” ‖ ‖“Failure” “Design Acceptable” ≔DCRT =――Tu Rn 0.702 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- Alternative Connection Design - BENT PL 1/4"X4" Design Loads ≔Tu 702.2 lbf Stub Force ≔Vu 344.5 lbf Stub Force Subrail distributes the load to each main rail equally Design Capacity - Bending of plate from Vertical Loads ≔t 0.25 in ≔w 4 in ≔Fy 33 ksi ≔Ωb 1.67 ≔Mn =⋅――⋅w t 2 4 ――Fy Ωb 1.235 ⋅kip in ≔lever_arm =――――――― ―――――――-5.375 in 1.859 in 2 2 0.879 in ≔Mu =⋅――Tu 2 lever_arm 0.309 ⋅kip in =if else >Mn Mu ‖ ‖“Design Acceptable” ‖ ‖“Failure” “Design Acceptable” ≔DCRT =――Mu Mn 0.25 Design Capacity - 1/2 Dia Bolts A307, Tension & Shear ≔Fnt 45 ksi ≔Fnv 27 ksi ≔Omega_bolt 2 ≔Ab =――――――⋅π ((⋅0.5 in 0.8))2 4 0.126 in 2 Check Tension Check Shear ≔Tn =――――― ⋅Fnt Ab Omega_bolt 2827.433 lbf ≔Vn =――――― ⋅Fnv Ab Omega_bolt 1696.46 lbf =if else >Tn ――Tu 2 ‖ ‖“Design Acceptable” ‖ ‖“Failure” “Design Acceptable”=if else >Vn +――Vu 2 ――Tu 2 ‖ ‖“Design Acceptable” ‖ ‖“Failure” “Design Acceptable” ≔DCRT =―― ――Tu 2 Tn 0.124 ≔DCRV =―――― +――Vu 2 ――Tu 2 Vn 0.308 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 03/04/2024 ENGINEER DWG. REF _OS -- Combined Tension and Shear ≔frv =―――― +――Vu 2 ――Tu 2 Ab 4.165 ksi Required Shear Stress ≔F'nt =min ⎛ ⎜ ⎜⎝ ,Fnt -⋅1.3 Fnt ⋅―――――― ⋅Omega_bolt Fnt Fnv frv ⎞ ⎟ ⎟⎠ 44.618 ksi ≔Rn =⋅F'nt Ab 5.607 kip ≔DCRC =―――⋅Tu 0.5 Rn 0.063 Check Bearing for 1/4" PL ≔Rn =――――――――――⋅⋅⋅⋅⋅2.4 52 ksi 0.5 in 0.105 in Omega_bolt 3276 lbf ≔DCRB =―――― +――Vu 2 ――Tu 2 Rn 0.16 1900 E 4th St - 1011190678/9/2024 WALTER P MOORE STRUCTURAL CALCULATIONS 2.03 - RAUN 216-10 Soil Bearing Check Detail 01/S5-09 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 04/16/2024 ENGINEER DWG. REF _OS -- Footing stress distribution (centered) ADDED CALCULATIONS PER PLAN CHECK COMMENTS Geometric Properties: ≔L =((24 in))24 in ≔B =((24 in))24 in ≔A =⋅B L 4 ft 2 ≔Ix =―――⋅B L 3 12 1.333 ft 4 ≔yc =⋅0.5 B 1 ft ≔Iy =―――⋅L B 3 12 1.333 ft 4 ≔xc =⋅0.5 L 1 ft Slab self weight: ≔γconc 150 pcf ≔tslab 10 in ≔Wslab =⋅⋅⋅L B tslab γconc 500 lbf Max reactions. No moment due to pinned condition. ASD level loads: ≔PASD =⋅0.6 ((1445.31 lbf))867.19 lbf ≔MASD =⋅0.7 ((⋅0 lbf ft))0 ⋅lbf ft Stress surface points: ≔σ1 =+――PASD A ――――⋅MASD yc Ix 216.8 psf ≔σ2 =-――PASD A ――――⋅MASD yc Ix 216.8 psf X direction ≔σ3 =+――PASD A ――――⋅MASD xc Iy 216.8 psf ≔σ4 =-――PASD A ――――⋅MASD xc Iy 216.8 psf Y direction ≔σu =max ⎛⎝,,,abs ⎛⎝σ1⎞⎠abs ⎛⎝σ2⎞⎠abs ⎛⎝σ3⎞⎠abs ⎛⎝σ4⎞⎠⎞⎠216.8 psf Soil Bearing capacity: ≔Psoil 1500 psf Code minimum soil bearing preasure per CBC ≔DCRsoil =――σu Psoil 0.145 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 04/16/2024 ENGINEER DWG. REF _OS -- LRFD level loads: ≔PLRFD =⋅0.9 ((1445.31 lbf))1300.78 lbf ≔MLRFD =⋅1.0 ((⋅0 lbf ft))0 ⋅lbf ft Stress surface points: ≔σ1 =+―――PLRFD A ――――⋅MLRFD yc Ix 325.19 psf ≔σ2 =-―――PLRFD A ――――⋅MLRFD yc Ix 325.19 psf X direction ≔σ3 =+―――PLRFD A ――――⋅MLRFD xc Iy 325.19 psf ≔σ4 =-―――PLRFD A ――――⋅MLRFD xc Iy 325.19 psf Y direction ≔σu =max ⎛⎝,,,abs ⎛⎝σ1⎞⎠abs ⎛⎝σ2⎞⎠abs ⎛⎝σ3⎞⎠abs ⎛⎝σ4⎞⎠⎞⎠325.19 psf Soil Bearing capacity: ≔Psoil 1500 psf Code minimum soil bearing preasure per CBC ≔DCRsoil =――σu Psoil 0.217 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 04/16/2024 ENGINEER DWG. REF _OS -- Footing stress distribution (offset) Geometric Properties: ≔L =((24 in))24 in ≔e 6.5 in ≔B =((24 in))24 in ≔A =⋅B L 4 ft 2 ≔Ix =―――⋅B L 3 12 1.333 ft 4 ≔yc =⋅0.5 B 1 ft ≔Iy =―――⋅L B 3 12 1.333 ft 4 ≔xc =⋅0.5 L 1 ft Slab self weight: ≔γconc 150 pcf ≔tslab 10 in ≔Wslab =⋅⋅⋅L B tslab γconc 500 lbf Max reactions. No moment due to pinned condition. ASD level loads: ≔PASD =⋅0.6 ((1445.31 lbf))867.19 lbf ≔MASD =⋅0.7 ⎛⎝⋅PASD e⎞⎠328.81 ⋅lbf ft Stress surface points: ≔σ1 =+――PASD A ――――⋅MASD yc Ix 463.4 psf ≔σ2 =-――PASD A ――――⋅MASD yc Ix -29.81 psf X direction ≔σ3 =+――PASD A ――――⋅MASD xc Iy 463.4 psf ≔σ4 =-――PASD A ――――⋅MASD xc Iy -29.81 psf Y direction ≔σu =max ⎛⎝,,,abs ⎛⎝σ1⎞⎠abs ⎛⎝σ2⎞⎠abs ⎛⎝σ3⎞⎠abs ⎛⎝σ4⎞⎠⎞⎠463.4 psf Soil Bearing capacity: ≔Psoil 1500 psf Code minimum soil bearing preasure per CBC ≔DCRsoil =――σu Psoil 0.309 1900 E 4th St - 1011190678/9/2024 JOB NAME _Kaiser SAN 1st Fl GenRad JOB NO. DATE _S09-23018 04/16/2024 ENGINEER DWG. REF _OS -- LRFD level loads: ≔PLRFD =⋅0.9 ((1445.31 lbf))1300.78 lbf ≔MLRFD =⋅1.0 ⎛⎝⋅PASD e⎞⎠469.73 ⋅lbf ft Stress surface points: ≔σ1 =+―――PLRFD A ――――⋅MLRFD yc Ix 677.49 psf ≔σ2 =-―――PLRFD A ――――⋅MLRFD yc Ix -27.1 psf X direction ≔σ3 =+―――PLRFD A ――――⋅MLRFD xc Iy 677.49 psf ≔σ4 =-―――PLRFD A ――――⋅MLRFD xc Iy -27.1 psf Y direction ≔σu =max ⎛⎝,,,abs ⎛⎝σ1⎞⎠abs ⎛⎝σ2⎞⎠abs ⎛⎝σ3⎞⎠abs ⎛⎝σ4⎞⎠⎞⎠677.49 psf Soil Bearing capacity: ≔Psoil 1500 psf Code minimum soil bearing preasure per CBC ≔DCRsoil =――σu Psoil 0.452 1900 E 4th St - 1011190678/9/2024 WALTER P MOORE STRUCTURAL CALCULATIONS 2.04 - RAUN 216-10 Hilti Anchorage Report Detail 01/S5-09 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.93 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | Copy - RAUN 216-10 - Base Anchor Page: Specifier: E-Mail: Date: 1 4/19/2024 Specifier's comments: 1 Anchor Design 1.1 Input data Anchor type and diameter: Kwik Bolt TZ2 - CS 3/4 (3 1/4) hnom1 Item number: 2210311 KB-TZ2 3/4x5 1/2 Effective embedment depth: hef,act = 3.250 in., hnom = 4.000 in. Material: Carbon Steel Evaluation Service Report: ESR-4266 Issued I Valid: 12/17/2021 | 12/1/2023 Proof: Design Method ACI 318-19 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.375 in. Anchor plateCBFEM : lx x ly x t = 6.000 in. x 11.000 in. x 0.375 in.; Profile: Square HSS (AISC), HSS5X5X.375; (L x W x T) = 5.000 in. x 5.000 in. x 0.375 in. Base material: cracked concrete, 3000, fc' = 3,000 psi; h = 6.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar CBFEM - The anchor calculation is based on a component-based Finite Element Method (CBFEM) Geometry [in.] & Loading [lb, in.lb] 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.93 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | Copy - RAUN 216-10 - Base Anchor Page: Specifier: E-Mail: Date: 2 4/19/2024 1.1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = -2,216; Vx = 270; Vy = 258; Mx = 0; My = 0; Mz = 0; no 3 1.2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 0 185 135 127 2 0 188 135 131 resulting tension force in (x/y)=(-/-): 0 [lb] resulting compression force in (x/y)=(-0.000/0.001): 2,231 [lb] Anchor forces are calculated based on a component-based Finite Element Method (CBFEM) 1.3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*N/A N/A N/A N/A Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**N/A N/A N/A N/A * highest loaded anchor **anchor group (anchors in tension) 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.93 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | Copy - RAUN 216-10 - Base Anchor Page: Specifier: E-Mail: Date: 3 4/19/2024 1.4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*188 8,977 3 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**374 17,176 3 OK Concrete edge failure in direction **N/A N/A N/A N/A * highest loaded anchor **anchor group (relevant anchors) 1.4.1 Steel Strength Vsa = ESR value refer to ICC-ES ESR-4266 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi] 0.24 105,904 Calculations Vsa [lb] 13,811 Results Vsa [lb]f steel f Vsa [lb]Vua [lb] 13,811 0.650 8,977 188 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.93 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | Copy - RAUN 216-10 - Base Anchor Page: Specifier: E-Mail: Date: 4 4/19/2024 1.4.2 Pryout Strength Vcpg = kcp [(ANc ANc0)y ec,N y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1b) f Vcpg ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ec,N = (1 1 + 2 e' N 3 hef )£ 1.0 ACI 318-19 Eq. (17.6.2.3.1) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ec1,N [in.]ec2,N [in.]ca,min [in.] 2 3.250 0.000 0.000 ∞ y c,N cac [in.]kc l a f' c [psi] 1.000 12.000 21 1.000 3,000 Calculations ANc [in.2]ANc0 [in.2]y ec1,N y ec2,N y ed,N y cp,N Nb [lb] 173.06 95.06 1.000 1.000 1.000 1.000 6,739 Results Vcpg [lb]f concrete f Vcpg [lb]Vua [lb] 24,537 0.700 17,176 374 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.93 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: | Copy - RAUN 216-10 - Base Anchor Page: Specifier: E-Mail: Date: 5 4/19/2024 1.5 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates as per current regulations (ETAG 001/Annex C, EOTA TR029, etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. • The anchor design methods in PROFIS Engineering require rigid anchor plates, as per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means that the anchor plate should be sufficiently rigid to prevent load re-distribution to the anchors due to elastic/plastic displacements. The user accepts that the anchor plate is considered close to rigid by engineering judgment." 1900 E 4th St - 1011190678/9/2024 www.hilti.com Hilti PROFIS Engineering 3.0.93 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: | Copy - RAUN 216-10 - Base Anchor Page: Specifier: E-Mail: Date: 6 4/19/2024 Coordinates Anchor [in.] Anchor x y c-x c+x c-y c+y 1 -0.000 -4.000 ---- 2 -0.000 4.000 ---- 1.6 Installation data Anchor type and diameter: Kwik Bolt TZ2 - CS 3/4 (3 1/4) hnom1 Profile: Square HSS (AISC), HSS5X5X.375; (L x W x T) = 5.000 in. x 5.000 in. x 0.375 in. Item number: 2210311 KB-TZ2 3/4x5 1/2 Hole diameter in the fixture: df = - in. Maximum installation torque: 1,324 in.lb Plate thickness (input): 0.375 in. Hole diameter in the base material: 0.750 in. Hole depth in the base material: 4.250 in. Drilling method: Hammer drilled Minimum thickness of the base material: 5.500 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti KB-TZ2 stud anchor with 4 in embedment, 3/4 (3 1/4) hnom1, Carbon steel, installation per ESR-4266 1.6.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque wrench • Hammer 1900 E 4th St - 1011190678/9/2024 Hilti PROFIS Engineering 3.0.93 www.hilti.com Company:Page:7 Address:Specifier: Phone I Fax:|E-Mail: Design:Copy -RAUN 216-10 - Base Anchor Date:4/19/2024 Fastening point: Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 2 Anchor plate design 2.1 Input data Anchor plate:Shape: Rectangular lx x ly x t = 6.000 in x 11.000 in x 0.375 in Calculation: CBFEM Material: ASTM A36; Fy = 36,000 psi; εlim = 5.00% Anchor type and size:Kwik Bolt TZ2 - CS 3/4 (3 1/4) hnom1, hef = 3.250 in Anchor stiffness:The anchor is modeled considering stiffness values determined from load displacement curves tested in an independent laboratory. Please note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution results. Design method:AISC and LRFD-based design using component-based FEM Stand-off installation:eb = 0.000 in (No stand-off); t = 0.375 in Profile:HSS5X5X.375; (L x W x T x FT) = 5.000 in x 5.000 in x 0.375 in x - Material: ASTM A500 Gr.B Rect; Fy = 46,000 psi; εlim = 5.00% Eccentricity x: -0.000 in Eccentricity y: 0.000 in Base material:Cracked concrete; 3000; fc,cyl = 3,000 psi; h = 6.000 in Welds (profile to anchor plate):Type of redistribution: Plastic Material: E70xx Mesh size:Number of elements on edge: 8 Min. size of element: 0.394 in Max. size of element: 1.969 in 2.2 Summary Description Profile Anchor plate Concrete [%] sEd [psi]ePl [%]sEd [psi]ePl [%]Hole bearing [%] 1 Combination 1 675 0.00 823 0.00 1 2 2.3 Anchor plate classification Results below are displayed for the decisive load combinations: Combination 1 Anchor tension forces Equivalent rigid anchor plate (CBFEM)Component-based Finite Element Method (CBFEM) anchor plate design Anchor 1 0 lb 0 lb Anchor 2 0 lb 0 lb User accepted to consider the selected anchor plate as rigid by his/her engineering judgement. This means the anchor design guidelines can be applied. 2.4 Profile/Stiffeners/Plate Profile and stiffeners are verified at the level of the steel to concrete connection. The connection design does not replace the steel design for critical cross sections, which should be performed outside of PROFIS Engineering. 2.4.1 Equivalent stress and plastic strain Part Load combination Material fy [psi]elim [%]sEd [psi]ePl [%]Status Plate Combination 1 ASTM A36 36,000 5.00 823 0.00 OK Profile Combination 1 ASTM A500 Gr.B Rect 46,000 5.00 675 0.00 OK Profile Combination 1 ASTM A500 Gr.B 46,000 5.00 573 0.00 OK 1900 E 4th St - 1011190678/9/2024 Hilti PROFIS Engineering 3.0.93 www.hilti.com Company:Page:8 Address:Specifier: Phone I Fax:|E-Mail: Design:Copy -RAUN 216-10 - Base Anchor Date:4/19/2024 Fastening point: Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Part Load combination Material fy [psi]elim [%]sEd [psi]ePl [%]Status Rect Profile Combination 1 ASTM A500 Gr.B Rect 46,000 5.00 648 0.00 OK Profile Combination 1 ASTM A500 Gr.B Rect 46,000 5.00 535 0.00 OK 2.4.1.1 Equivalent stress Results below are displayed for the decisive load combination: 1 - Combination 1 46,000 psi 0 psi 1900 E 4th St - 1011190678/9/2024 Hilti PROFIS Engineering 3.0.93 www.hilti.com Company:Page:9 Address:Specifier: Phone I Fax:|E-Mail: Design:Copy -RAUN 216-10 - Base Anchor Date:4/19/2024 Fastening point: Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 9 2.4.1.2 Plastic strain Results below are displayed for the decisive load combination: 1 - Combination 1 5.00% 0.00% 2.4.2 Plate hole bearing resistance, AISC 360-16 Section J3 Decisive load combination: 1 - Combination 1 Equations Rn =min(1.2 lc t Fu , 2.4 d t Fu)(AISC 360-16 J3-6a, c) FRn =0.75 Rn V ≤FRn Variables lc [in]t [in]Fu [psi]d [in]Rn [lb] Anchor 1 1.786 0.375 58,000 0.750 39,171 Anchor 2 3.781 0.375 58,000 0.750 39,171 Results V [lb]FRn [lb]Utilization [%]Status Anchor 1 185 29,378 1 OK Anchor 2 188 29,378 1 OK 2.5 Concrete Decisive load combination: 1 - Combination 1 1900 E 4th St - 1011190678/9/2024 Hilti PROFIS Engineering 3.0.93 www.hilti.com Company:Page:10 Address:Specifier: Phone I Fax:|E-Mail: Design:Copy -RAUN 216-10 - Base Anchor Date:4/19/2024 Fastening point: Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 10 2.5.1 Compression in concrete under the anchor plate 74 psi 0 psi 2.5.2 Concrete block compressive strength resistance check, AISC 360-16 Section J8 1900 E 4th St - 1011190678/9/2024 Hilti PROFIS Engineering 3.0.93 www.hilti.com Company:Page:11 Address:Specifier: Phone I Fax:|E-Mail: Design:Copy -RAUN 216-10 - Base Anchor Date:4/19/2024 Fastening point: Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 11 Equations Fp =F fp,max fp,max =0.85 fc' √( A 2 A 1 ) ≤ 1.7 fc;√( A 2 A 1 ) ≤ 2 s = N A 1 Utilization =s Fp Variables N [lb]fc' [psi]F A1 [in²]A2 [in²] 2,231 3,000 0.65 46.89 855.31 Results Load combination Fp [psi]s [psi]Utilization [%]Status Combination 1 3,315 48 2 OK 2.6 Symbol explanation A1 Loaded area of concrete A2 Supporting area d Nominal diameter of the bolt elim Limit plastic strain ePl Plastic strain from CBFEM results fc Concrete compressive strength fc'Concrete compressive strength Fu Specified minimum tensile strength of the connected material Fp Concrete block design bearing strength fp,max Concrete block design bearing strength maximum fy Yield strength lc Clear distance, in the direction of the force, between the edge of the hole and the edge of the adjacent hole or edge of the material N Resulting compression force s Average stress in concrete sEd Equivalent stress F Resistance factor FRn Factored resistance t Thickness of the anchor plate V Resultant of shear forces Vy, Vz in bolt. 2.7 Warnings ●By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified anchor plate may not behave rigid. Please, validate the results with a professional designer and/or structural engineer to ensure suitability and adequacy for your specific jurisdiction and project requirements. ●The anchor is modeled considering stiffness values determined from load displacement curves tested in an independent laboratory. Please note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution results. 1900 E 4th St - 1011190678/9/2024 Hilti PROFIS Engineering 3.0.93 www.hilti.com Company:Page:12 Address:Specifier: Phone I Fax:|E-Mail: Design:Copy -RAUN 216-10 - Base Anchor Date:4/19/2024 Fastening point: Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 12 3 Summary of results Design of the anchor plate, anchors, welds and other elements are based on CBFEM (component based finite element method) and AISC. Load combination Max. utilization Status Anchors Combination 1 3%OK Anchor plate Combination 1 3%OK Concrete Combination 1 2%OK Profile Combination 1 2%OK Fastening meets the design criteria! 1900 E 4th St - 1011190678/9/2024 Hilti PROFIS Engineering 3.0.93 www.hilti.com Company:Page:13 Address:Specifier: Phone I Fax:|E-Mail: Design:Copy -RAUN 216-10 - Base Anchor Date:4/19/2024 Fastening point: Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 13 4 Remarks; Your Cooperation Duties ●Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. ●You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 1900 E 4th St - 1011190678/9/2024