Loading...
HomeMy WebLinkAbout1806 W 15th St & Unit #2 - PlanW/D (N) ADU (E) DWELLING SITE LEGEND (E) PROPERTY LINE D GMGM (E) ELECTRICAL PANEL (E) GAS METER (E) WATER HEATER (E) CONDENSER UNIT (E) WATER METER (E) UTILITY POLE (E) CLEANOUT P P A C EP WH WM GRASS/TURF CONCRETE EASEMENT AREA PROJECT DIRECTORY ARCHITECTURAL DESIGNER ADU RESOURCE CENTER 600 N. BRAND BLVD. SUITE#560 GLENDALE, CA. 91709 PHONE: (213) 408-3831 CONTACT: JIA YU EMAIL: ARCHITECTURE@ADURESOURCECENTER.COM OWNER; DANA LUSIANI STRUCTURAL SPS ENGINEERING 15445 VENTURA BLVD. #63 SHERMAN OAKS, CA 91403 PHONE: (818) 747-7269 CONTACT: SHANT SHAHBAZ M. SC. P. E. EMAIL: SHANT.SPS@GMAIL.COM ADDRESS: 1806 W 15TH ST, SANTA ANA, CA 92706 CONTACT: ARCHITECTURE@ADURESOURCECENTER.COM (213)408-3821 TITLE 24 ENGINEER NALSER ENGINEERING 1236 N COLUMBUS AVE, UNIT 04, GLENDALE, CA 91202 PHONE: (818) 913-7525 CONTACT: SEROP NALBANDIAN, M.SC, PE, EMAIL: NALSERENGINEERING@GMAIL.COM GN1 GN2 GD1 GD2 GENERAL DETAILS S1 FOUNDATION PLAN S2 ROOF FRAMING PLAN STRUCTURAL Sheet Number Sheet Name GN1 GENERAL NOTES GENERAL NOTES GENERAL DETAILS S3 DETAILS S4 DETAILS T-24 TITLE 24 TITLE 24 T-1 T-2 Sheet Number Sheet Name EXISTING SFR CONVERSION ( 146.56 SF) + ADDITION (335.02 SF) TO NEW ONE STORY ATTACHED ADU (491.08 SF) REMOVE OF PATIO COVER AND RELOCATION OF SFD A/C CONDENSER, WIN 03 IS REPLACING 3'x3' WINDOW IN THE EXISTING BEDROOM 1806 W 15TH ST, SANTA ANA, CA 92706 PROJECT DESCRIPTION PROJECT DESCRIPTION PROJECT ADDRESS LEGAL DESCRIPTION LOT AREA ZONING INFORMATION APN/PARCEL ID: 40509124 TRACT 1925 BLOCK LOT 4 6,182 SF R CODES ALLOWABLE ADU HEIGHT 18' PROPOSED BLDG HEIGHT 16' - 1" OCCUPANCY TYPE R-3 - RESIDENTIAL - SINGLE • • • • • • • 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA BUILDING (CBC) AND FIRE CODES 2022 CALIFORNIA TITLE 24 ENERGY REQUIREMENTS (T24) 2022 CALIFORNIA GREEN BUILDING SANTA ANA MUNICIPLE CODE COSNTRUCTION TYPE FIRE SPRINKLERED (HOUSE) N/A - MAIN HOUSE NOT SPRINKLERED FIRE SPRINKLERED (ADU) NO HIGH FIRE HAZARD AREA NO FLOOD ZONE NO TYPE-VB HILLSIDE AREA NO EXISTING HOUSE SIZE EXISTING TO REMAIN - NOT PART OF SCOPE PROPOSED ADU SIZE 491.08 SF VICINITY AND ASSESSOR MAP GMGM (E) ELECTRICAL PANEL 200A (E) GAS METER (E) WATER HEATER (N)EXISTING CONDENSER UNIT RELOCATION (E) UTILITY POLE PP ACAC EP WH EXISTING 1 STORY MAIN SFR 1,304 SF 1806 W. 15TH ST. SANTA ANA CA. 92706 20 ' - 5 " 22 ' - 7 " 9' - 0 " (E) ADDITIONAL OVER-HANG TO BE REMOVED EXISTING GARAGE (451 SF) (E) 5'-9" CHAIN LINK FENCE (E) CONCRETE (E) GRASS (E) LANDSCAPE 5'-2" 8'-9" 9'-2" 60.00' Property line 10 2 . 0 0 ' Pr o p e r t y l i n e 10 2 . 0 0 ' Pr o p e r t y l i n e 60.00' Property line NEW PROPOSED ONE STORY ATTACHED ADU (146.56 SF PARTIAL CONVERSION OF THE EXISTING + 335.02 SF ADDITION) TOTAL 491.08 SF 6' - 1 1 1 / 2 " 5' - 3 1 / 2 " WH(N)CONDENSER UNIT ACAC (N) HEAT PUMP WATER HEATEREA S E M E N T 6' - 0 " (E) HARDSCAPE N W 15TH ST 5% 5% (N) CONCRETE 3' - 4 " (E ) L A N S C A P E 6' - 0 " 4'-0" 5% 5% 5% 5% 5% 2% 2% 2% 2% 5% 5%5%5% DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:17 PM A000 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 PROJECT INFOMATION 1806 W 15TH ST & 1806 W 15TH ST, UNIT 2, SANTA ANA, CA 92706 ARCHITECTURAL Sheet Number Sheet Name A000 PROJECT INFOMATION A100 EXISTING SITE PLAN A101 EXISTING FLOOR PLAN A102 EXISTING ROOF PLAN A103 EXISTING ELEVATIONS A104 EXISTING ELEVATIONS A110 PROPOSED SITE PLAN A111 PROPOSED 1ST FLOOR PLAN A131 ROOF PLAN A200 ELEVATIONS A201 ELEVATIONS A210 SECTIONS A301 SPECIFICATIONS A302 SPECIFICATIONS A303 SPECIFICATIONS A304 PROJECT INFORMATION GENERAL Sheet Number Sheet Name G001 GENERAL NOTES G002 CAL GREEN - LOS ANGELES G003 CAL GREEN 1 G004 CAL GREEN 2 G005 AGING-IN-PLACE No. Description Date SCALE: 1/8" = 1'-0" SITE PLAN 1 LOT COVERAGE CALCULATION LOT AREA 35% OF LOT AREA 2,163.7 SF. EXISTING SFR AREA 1,304 SF. EXISTING GARAGE 451 SF. EXISITING TOTAL LOT COVERAGE: 1,755 SF (28.3%) 6,182 SF NEW PROPOSED ADU 355.90 SF (ADDITION) + 146.56 SF (EXISTING) NEW TOTAL LOT COVERAGE: 2,110.9 SF (34%) THE APPLICANT/PROPERTY OWNER SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING UTILITY EASEMENTS AND /OR CLEARANCE ON-SITE THAT MAY AFFECT THE PROJECT THE ADU SF / SFD SF RATIO IS FOR PARK AND REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN "SFR SF" OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN 'SFR SF' OF THE EXISTING RESIDENCE. ADU SF / SFD SF RATIO: 491.08 SF / 1157.44 SF = 0.42 Bldg #'s 101119296-97 APPROVALS: PLNG - C. Santana BLDG - CSG POLICE - B. Martin PUBLIC WORKS - Y. Soto 1806 W 15th St & Unit #25/1/2025 DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:45 PM G001 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 GENERAL NOTES THE PROJECT SHALL DEMONSTRATE A 2-% REDUCTION IN WATER USE BY SPECIFYING PLUMBING FIXTURES AND FIXTURES THAT MEET THE FLOW RATES LISTED BELOW, OR THROUGH A CALCULATION SHOWING A 20% REDUCTION FROM BASELINE VALUES LISTED IN CALGREEN TABLE 4.303.1. SHOWERHEADS:1.8 GALLONS PER MINUTE (GPM) 1* @80 psi LAVATORY FAUCET- RESIDENTIAL: 1.2 GPM @60 psi KITCHEN FAUCETS:1.8 GPM @60 psi WATER CLOSETS:1.28 GALLONS PER FLUSH 2* URINALS:0.125 GALLON PER FLUSH METERING FAUCETS:0.2 GALLON PER CYCLE NOTES: 1. THE COMBINED FLOW RATE OF MULTIPLE SHOWER HEADS SHALL NOT EXCEED THE MAXIMUM FLOW RATE, OR THE SHOWER SHALL BE DESIGNED TO PERMIT ONE SHOWERHEAD TO BE IN OPERATION AT A TIME. 2. THE EFFECTIVE FLUSH VOLUME FOR DUAL-FLUSH TOILETS IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO REDUCED FLUSHES AND ONE FULL FLUSH. ELECTRICAL NOTES: PER 2022 CALIFORNIA ELECTRICAL CODE A. PANEL LOCATIONS PANELS SHALL NOT BE LOCATED IN THE VICINITY OF EASILY IGNITABLE MATERIAL, SUCH AS CLOTHES CLOSETS, OR IN BATHROOMS (CEC 240-24(D)). B. NON-METALLIC SHEATHED CABLE (CEC 334) NON-METALLIC SHEATHED CABLE SHALL BE: 1. PROTECTED BY RIGID METAL CONDUIT, INTERMEDIATE METAL CONDUIT,ELECTRICAL METALLIC TUBING, SCHEDULE 80 PVC CONDUIT, PIPE, OR OTHER MEANS WHEN CABLE IS EXPOSED OR SUBJECT TO PHYSICAL DAMAGE. (CEC 334.15(B)) 2. PROTECTED BY A 1.16 INCH STEEL PLATE OR SLEEVE, OR BE NOT LESS THAN 1-1/4 INCH FROM THE NEAREST EDGE OF THE FRAMING MEMBER, WHEN INSTALLED THROUGH FRAMING MEMBERS. STEEL PLATES OR SLEEVES ARE REQUIRED ON ALL DOUBLE SHEAR WALLS WHEN CABLE IS INSTALLED EITHER THROUGH OR PARALLEL TO FRAMING MEMBERS (CEC 334.17). 3. PROTECTED BY GUARD STRIPS WITHIN 6FT OF AN ATTIC ACCESS WHEN NO PERMANENT STAIRS OR LADDERS ARE PROVIDED. (CEC 334.23, 320.23) 3. PROTECTED BY GUARD STRIPS IN THE ENTIRE ATTIC WHEN PERMANENT STAIRS OR LADDERS ARE PROVIDED. ACCESS PANELS OR DOORS FROM THE SECOND FLOOR INTO THE ATTIC ARE CONSIDERED PERMANENT ACCESS AND GUARD STRIPS ARE REQUIRED IN THE ENTIRE ATTIC. 5. HAVE A BENDING RADIUS NOT LESS THAN 5 TIMES THE DIAMETER OF THE CABLE (CEC 334.24). 6. SUPPORTED AT INTERVALS NOT EXCEEDING 4-1/2 FEET AND WITHIN 12" OF EVERY OUTLET BOX, JUNCTION BOX, CABINET OR FITTING (CEC 334.30). C. CIRCUITS AND RECEPTACLES 1.RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6 FT. FROM AN OUTLET, INCLUDING ANY WALL SPACE 2 FT. WIDE OR GREATER. NOTE: A FIXED PANEL OF A SLIDING GLASS DOOR IS CONSIDERED WALL SPACE. 2. IN KITCHENS, BREAKFAST ROOMS, PANTRIES AND DINING ROOMS A MINIMUM OF 2-20A CICUITS SHALL BE PROVIDED (CEC 210.11 (C)(1)). COUNTER SPACE RECEPTACLES SHALL BE GFCI (CEC 210.8 (A)) AND INSTALLED: - AT EACH WALL COUNTER SPACE THAT IS 12 IN. OR GREATER (CEC 210.52 (C)(1)); - NO MORE THAN 48 IN. OC. (CEC 210.52 (C)(1)); - MAXIMUM 24 IN. FROM THE END OF THE COUNTER (CEC 210.52 (C)(1)); - MAXIMUM 20 IN. ABOVE COUNTER SURFACE (CEC 210.52 (C)(3)); - ON ISLAND COUNTER SPACES (ONE RECEPTACLE MIN.) NOT MORE THAN 12 IN. BELOW COUNTER SURFACE (CEC 210.52 (C)(3) EXCEPTION). AN ISLAND WITH LESS THAN 12" BEHIND A RANGE TOP OF SINK IS CONSIDERED AS DIVIGING THE COUNTERTOP INTO TWO SEPARATE SPACES (CEC 210.52 (C)(3)). - ON PENINSULAR COUNTER SPACES (ONE RECEPTACLE MIN.) NOT MORE THAN 12 IN. BELOW COUNTER SURFACE (CEC) 210.52 (C)(3) EXCEPTION)); 3. BATHROOMS SHALL HAVE A SEPARATE 20A CIRCUIT (CEC 210.11 (C)(3)) WITH AT LEAST ONE GFCI WALL RECEPTCLE WITHIN 36 IN. OF EACH BASIN (CEC 210.8 (A)(1); CEC 210.52 (D)). 4. LAUNDRY ROOMS SHALL HAVE A SEPARATE 20A CIRCUIT WITH AT LEAST ONE RECEPTACLE SHALL BE PROVIDED (CEC 210.11 (C)(2)). ALL RECEPTACLES WITHIN 6 FT. OF A SINK SHALL BE GFCI (CEC 210.52(F)). 5. IN GARAGES, AT LEAST ONE GFCI RECEPTACLE SHALL BE PROVIDED (CEC 210.52 (G)). ALL OTHER GARAGE RECEPTACLES EXCEPT THOSE DEDICATED TO AN APPLIANCE OR THAT ARE NOT READILY ACCESSIBLE SHALL BE GFCI. (CEC 210.8 (A)(2)) PER 2022 CALIFORNIA ELECTRICAL CODE 6. IN HALLWAYS OF 10 FT. OR MORE IN LENGTH, AT LEAST ONE RECEPTACLE SHALL BE PROVIDED (CEC 210.52 (H)). 7. OUTDOOR OUTLETS SHALL BE GFCI (CEC 210.8 (A) (3)). ONE OUTLET SHALL BE INSTALLED AT THE FRONT OF THE DWELLING AND ONE AT THE REAR OF THE DWELLING. RECEPTACLES SHALL BE ACCESSIBLE AT GRADE LEVEL AND NOT MORE THAN 6-1/2 FT. ABOVE GRADE (CEC 210.52 (E)). 8. ALL CRAWL SPACE RECEPTACLES SHALL BE GFCI (CEC 210.8(A)(4)). 9. ALL UNFINISHED BASEMENT RECEPTACLES SHALL BE GFCI UNLESS THEY ARE NOT READILY ACCESSIBLE OR ARE SERVICE A DEDICATED APPLIANCE (CEC 210.8 (A)(5)). 10. ALL RECEPTACLES WITHIN 6FT. OF A WET BAR SHALL BE GFCI (CEC 210.8(A)(7)). 11. ALL RECEPTACLES ON 15A OR 20A BRANCH CIRCUITS THAT SUPPLY FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY COMBINATION-TYPE ARC-FAULT CIRCUIT INTERRUPTERS (AFCI), INCLUDING SWITCHED OUTLETS (CEC 210.12(B)). 12. ALL RECEPTACLES SERVING APPLIANCES OR MOTORS WITH A RATING OF 1 HP OR 6 AMPS SHALL BE ON A SEPARATE CIRCUIT. 13. FOR HVAC EQUIPMENT, A SEPARATE 15A OR 20A CIRCUIT WITH AN ACCESSIBLE RECEPTACLE AT THE EQUIPMENT SHALL BE PROVIDED WITHIN 25 FT OF THE EQUIPMENT (CEC 210.63). IF LOCATED IN AN UNDER FLOOR AREA, THE RECETACLE SHALL BE GFCI (CEC 210.8 (4)). D. LIGHTING (CEC 210.70) 1. SWITCHED LIGHTING SHALL BE INSTALLED IN: - ALL HABITABLE ROOMS, BATHROOMS, HALLWAYS, AND STAIRWAYS AT EACH LEVEL, - AT ALL OUTDOOR ENTRANCES AND EXITS, - IN ALL ATTICS, UNDER FLOOR AREAS, UTILITY ROOMS AND BASEMENTS USED FOR STORAGE, - NEAR HVAC EQUIPMENT IN ATTIC, UNDER FLOOR AREAS, ROOMS OR BASEMENTS, WITH A SWITCH AT THE ACCESS POINT. 2. LIGHTING INSTALLED IN A CLOSET SHALL BE A SURFACE MOUNTED OR RECESSED FLUORESCENT FIXTURE OR A SURFACE MOUNTED INCANDESCENT FIXTURE WITH COMPLETELY ENCLOSED LAMPS OR RECESSED INCANDESCENT FIXTURE WITH COMPLETELY ENCLOSED LAMPS. SURFACE INCANDESCENT LIGHTING SHALL BE INSTALLED A MINIMUM OF 12 IN. FROM THE NEAREST POINT OF A STORAGE SPACE. SURFACE FLUORESCENT LIGHTING AND RECESSED LIGHTING SHALL BE INSTALLED A MINIMUM OF 6 IN. FROM THE NEAREST POINT OF A STORAGE SPACE. (CEC 410.16.(C)). E. FANS IN BATHROOMS CONTAINING TUBS OR SHOWERS, A FAN CAPABLE OF EXHAUSTING 50 CFM SHALL BE INSTALLED (ENERGY STANDARDS 150 (O)). F. SMOKE ALARMS IN NEW CONSTRUCTION, SMOKE ALARMS SHALL RECIEVE THEIR PRIMARY POWER FROM THE BUILDING WIRING. THE WIRING SHALL BE PERMANENT AND INSTALLED WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION (CBC [F] 907.2.11.6). STORM WATER MANAGEMENT: 1. ERODED SEDIMENTS AND OTHER POLLUTANTS MUST BE RETAINED ON SITE AND MAY NOT BE TRANSPORTED FROM THE SITE VIA SHEETFLOW, SWALES, AREA DRAINS, NATURAL DRAINAGE COURSES OR WINDS. 2. STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND OR WATER. 3. FUELS, OILS, SOLVENTS AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE SYSTEM. 4. NON-STORMWATER RUNOFF FROM EQUIPMENT AND VEHICLE WASHING AND ANY OTHER ACTIVITY SHALL BE CONTAINED AT THE PROJECT SITE. 5. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES ON SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE. 6. TRASH AND CONSTRUCTOIN RELATED SOLID WASTES MUST BE DEPOSITED INTO A CONVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPEARSAL BY WIND. 7. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY. 8. ACCIDENTAL DESPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS. 9. ANY SLOPES WITH DISTURBED SOILS OR DENUDED OF VEGETATION MUST BE STABILIZED SO AS TO INHIBIT EROSION BY WIND AND WATER. 10. SCHEDULE CONSTRUCTION ACTIVITY TO REDUCE AREA AND DURATION OF SOIL EXPOSED TO EROSION BY WIND, RAIN, RUNOFF AND VEHICLE TRACKING. 1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2022 EDITION OF THE CBC, CRC, CMC, CPC, AND CEC AS ADOPTED AND AMENDED BY THE STATE OF CALIFORNIA IN TITLE 24 CCR AND THIS JURISDICTION. 2. SEPARATE PERMITS MAY BE REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, SHORING, GRADING, AND DEMOLITION. 3. ALL PROPERTY LINES, EASEMENTS, AND EXISTING BUILDINGS HAVE BEEN INDICATED ON THIS SITE PLAN. 4. A SECURITY FENCE SHALL BE PROVIDED AROUND THE CONSTRUCTION AREA THAT SHALL BE INSTALLED PRIOR TO EXCAVATION AND/OR FOUNDATION TRENCHING. (BMC 9-1-1-3302.3) 5. WATER SHALL BE PROVIDED ON THE SITE AND USED TO CONTROL DUST. 6. TEMPORARY TOILET FACILITIES SHALL BE PROVIDED ON SITE. (BMC 9-1-1-3305) 7. THE FINISH GRADE SHALL SLOPE A MIN. OF 5%, OR 6", TO A POINT 10 FEET FROM BUILDING FOUNDATION, OR TO AN APPROVED ALTERNATE METHOD OF DIVERTING WATER AWAY FROM THE FOUNDATION. SWALES SHALL SLOPE A MINIMUM OF 2%. (CRC R401.3) 8. THE TOP OF THE EXTERIOR FOUNDATION SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER A MINIMUM OF 12" PLUS 2%. (CRC R403.1.7.3) GENERAL NOTES: FOUNDATION NOTES: SECURITY REQUIREMENTS: 1. ALL ENTRY DOORS TO DWELLING UNITS OR GUEST ROOMS SHALL BE ARRANGED SO THAT THE OCCUPANT HAS A VIEW OF THE AREA IMMEDIATELY OUTSIDE THE DOOR WITHOUT OPENING THE DOOR. SUCH VIEW MAY BE PROVIDED BY A DOOR VIEWER, THROUGH WINDOWS LOCATED IN THE VICINITY OF THE DOOR OR THROUGH VIEW PORTS IN THE DOOR OR ADJOINING WALL. (6706) 2. SCREENS, BARRICADES, OR FENCES MADE OF A MATERIAL WHICH WOULD PRECLUDE HUMAN CLIMBING SHALL BE PROVIDED AT EVERY PORTION OF EVERY ROOF, BALCONY, OR SIMILAR SURFACE WHICH IS WITHIN 8 FT. OF THE UTILITY POLE OR ACCESS STRUCTURES. (6707) 3. WOOD FLUSH-TYPE DOORS SHALL BE 1 3/8" THICK MINIMUM WITH SOLID CORE CONSTRUCTION. (6709.1) DOOR STOPS OF IN-SWINGING DOORS SHALL BE OF ONE-PIECE CONSTRUCTION WITH THE JAMB, OR JOINED BY RABBET TO THE JAMB. (6709.4) 4. EVERY DOOR IN A SECURITY OPENING FOR AN APARTMENT HOUSE SHALL BE PROVIDED WITH INCANDESCENT LIGHT BULB (60 WATT MIN) AT A MAXIMUM HEIGHT OF 8 FEET ON THE EXTERIOR SIDE OF THE UNIT. (6708) 5. ALL PIN-TYPE DOOR HINGES ACCESSIBLE FROM OUTSIDE SHALL HAVE NON-REMOVABLE HINGE PINS. HINGES SHALL HAVE MIN. 1/4" DIA. STEEL JAMB STUD WITH 1/4" MIN. PROTECTION. THE STRIKE PLATE FOR LATCHES AND HOLDING DEVICE FOR PROJECTING DEAD BOLTS IN WOOD CONSTRUCTION SHALL BE SECURED TO THE JAMB AND THE WALL FRAMING WITH SCREWS NO LESS THAN 2-1/2" LONG. (6709.5, 6709.7) 6. PROVIDE DEAD BOLTS WITH HARDENED INSERTS; DEADLOCKING LATCH WITH KEY-OPERATED LOCKS ON EXTERIOR. DOORS MUST BE OPERABLE FROM THE INSIDE WITHOUT A KEY, SPECIAL KNOWLEDGE, OR SPECIAL EFFORT (LATCH NOT REQUIRED IN B, F, M AND S OCCUPANCIES). (6709.2) 7. STRAIGHT DEAD BOLTS SHALL HAVE A MIN. THROW OF 1" AND AN EMBEDMENT OF NOT LESS THAN 5/8", AND A HOOK-SHAPED OR AN EXPANDING-LUG DEADBOLT SHALL HAVE A MINIMUM THROW OF 3/4". (6709.2) 8. WOOD PANEL TYPE DOORS MUST HAVE PANELS AT LEAST 9/16 INCH THICK WITH SHAPED PORTIONS OF THE PANELS NOT LESS THAN 1/4 INCH THICK, AND INDIVIDUAL PANELS MUST BE NO MORE THAN 300 SQ. IN. IN AREA. MULLIONS SHALL BE CONSIDERED A PART OF ADJACENT PANELS EXCEPT MULLIONS NOT OVER 18 INCHES LONG MAY HAVE AN OVERALL WIDTH OF NOT LESS THAN 2 INCHES. STILES AND RAILS SHALL BE OF SOLID LUMBER IN THICKNESS WITH OVERALL DIMENSIONS OF NOT LESS THAN 1 3/8 INCHES AND 3 INCHES IN WIDTH. (6709.1 ITEM 2) 9. SLIDING GLASS DOORS SHALL BE PROVIDED WITH A DEVICE IN THE UPPER CHANNEL OF THE MOVING PANEL TO PROHIBIT RAISING AND REMOVAL OF THE MOVING PANEL FROM THE TRACK WHILE IN THE CLOSED POSITION. (6710) 10. SLIDING GLASS DOORS SHALL BE EQUIPPED WITH LOCKING DEVICES AND SHALL BE SO CONSTRUCTED AND INSTALLED THAT THEY REMAIN INTACT AND ENGAGED WHEN SUBJECTED TO THE TESTS SPECIFIED IN SEC. 6717.1 11. METAL OR WOODEN OVERHEAD AND SLIDING DOORS SHALL BE SECURED WITH A CYLINDER LOCK, PADLOCK WITH A MIN. 9/32" DIAMETER HARDENED STEEL SHACKLE BOLTED, HARDENED STEEL HASPS, METAL SLIDE BOARD, BOLT OR EQUIVALENT DEVICE UNLESS SECURED ELECTRICALLY OPERATED. (6711) 12. PROVIDE METAL GUIDES AT TOP AND BOTTOM OF METAL ACCORDION GRATE OR GRILLE-TYPE DOORS AND CYLINDER LOCKS OR PADLOCKS. CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDER LOCKS WHENEVER THE CYLINDER PROJECTS BEYOND THE FACE OF THE DOOR OR IS OTHERWISE ACCESSIBLE TO GRIPPING TOOLS. (6712) 13. IN GROUP B, F, M, AND S OCCUPANCIES, PANES OF GLAZING WITH AT LEAST ONE DIMENSION GREATER THAN 6 IN. BUT LESS THAN 48 IN, SHALL BE CONSTRUCTED OF TEMPERED OR APPROVED BURGLARY-RESISTANT MATERIAL OR PROTECTED WITH METAL BARS OR GRILLES. (6714) 14. GLAZED OPENINGS WITHIN 40" OF THE DOOR LOCK WHEN THE DOOR IS IN THE CLOSED AND LOCKED POSITION, SHALL BE FULLY TEMPERED GLASS OR APPROVED BURGLARY-RESISTANT MATERIAL, OR SHALL BE PROTECTED BY METAL BARS, SCREENS OR GRILLES HAVING A MAXIMUM OPENING OF 2". THE PROVISIONS OF THIS SECTION SHALL NOT APPLY TO VIEW PORTS OR WINDOWS WHICH DO NOT EXCEED 2" IN THEIR GREATEST DIMENSIONS. (6713) 15. LOUVERED WINDOWS SHALL BE PROTECTED BY METAL BARS OR GRILLES WITH OPENINGS THAT HAVE AT LEAST ONE DIMENSION OF 6" OR LESS, WHICH ARE CONSTRUCTED TO PRECLUDE HUMAN ENTRY. (6715.3) 16. OTHER OPENABLE WINDOWS SHALL BE PROVIDED WITH SUBSTANTIAL LOCKING DEVICES. IN GROUP B, F, M AND S OCCUPANCIES, SUCH DEVICES SHALL BE GLIDE BARS, BOLTS, CROSS-BARS, AND/OR PADLOCKS WITH MINIMUM 9/32" HARDENED STEEL SHACKLES AND BOLTED, HARDENED STEEL HASPS. (6715.2) 17. SLIDING WINDOWS SHALL BE PROVIDED WITH LOCKING DEVICE IN THE UPPER CHANNEL OF THE MOVING PANEL TO PROHIBIT RAISING AND REMOVAL OF THE MOVING PANEL IN THE CLOSED OR PARTIALLY OPEN POSITION. (6715.1) 18. SLIDING WINDOWS SHALL BE EQUIPPED WITH LOCKING DEVICES AND SHALL BE SO CONSTRUCTED AND INSTALLED THAT THEY REMAIN INTACT AND ENGAGED WHEN SUBJECTED TO THE TESTS SPECIFIED IN SEC. 6717.2. 19. ANY RELEASE FOR METAL BARS, GRILLES, GRATES OR SIMILAR DEVICES CONSTRUCTED TO PRECLUDE HUMAN ENTRY THAT ARE INSTALLED SHALL BE LOCATED ON THE INSIDE OF THE ADJACENT ROOM AND AT LEAST 24 INCHES FROM THE CLOSEST OPENING THROUGH SUCH METAL BARS, GRILLES, GRATES OR SIMILAR DEVICES THAT EXCEEDS TWO INCHES IN ANY DIMENSION. (6715.4) 20 ALL OTHER OPENINGS MUST BE PROTECTED BY METAL BARS OR GRILLES WITH OPENINGS OF NOT LESS THAN 6 INCHES IN ONE DIMENSION. (6716) 1. CONCRETE STRENGTH FOR FOUNDATION SHALL BE 2,500 PSI MIN. (CRC R404.1.3.3.1. TABLE R402.2) 2. MINIMUM FOOTING REINFORCEMENT SHALL BE ONE #4 BAR TOP AND BOTTOM (CRC R403.1.3). 3. MINIMUM ANCHOR BOLT SIZE AND SPACING SHALL BE 5.8" DIA. AB @ 72" OC., WITH 7" EMBEDMENT, AND 3" X 3" X 1/4" PLATE WASHERS. ANCHOR BOLTS SHALL BE LOCATED A MAXIMUM OF 12" AND 4 1/2" MINIMUM FROM THE END OF THE PLATE (CRC R403.1.6, R602.11.1). WATER CONSERVATION: ELECTRICAL NOTES: A. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. B. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWNSTREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE 170,158) (SEPARATE PLUMBING PERMIT IS REQUIRED). C. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR TO AN APPROVED SEWAGE DISPOSAL SYSTEM (R306.3). D. KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND CONNECTED TO AN APPROVED WATER SUPPLY (R306.4). E. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR (R307.2). F. PROVIDE ULTRA-FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. G. UNIT SKYLIGHTS SHALL BE LABELED BY A HATHORNEWOOD CITY APPROVED LABELING AGENCY. SUCH LABEL SHALL STATE THE APPROVED LABELING AGENCY NAME, PRODUCT DESIGNATION AND PERFORMANCE GRADE RATING. (RESEARCH REPORT NOT REQUIRED). (R308.6.9) H. WATER HEATER MUST BE STRAPPED TO WALL. (SEC. 507.3, LAPC) I. FOR EXISTING POOL ON SITE, PROVIDE AN ALARM FOR DOORS TO THE DWELLING THAT FORM A PART OF THE POOL ENCLOSURE. THE ALARM SHALL SOUND CONTINUOUSLY FOR A MIN. OF 30 SECONDS WHEN THE DOOR IS OPENED. IT SHALL AUTOMATICALLY RESET AND BE EQUIPPED WITH A MANUAL MEANS TO DEACTIVATE (FOR 15 SECS. MAX.) FOR A SINGLE OPENING. THE DEACTIVATION SWITCH SHALL BE AT LEAST 54" ABOVE THE FLOOR. (6109 OF LABC) J. FOR EXISTING POOL ON SITE, PROVIDE ANTI– ENTRAPMENT COVER MEETING THE CURRENT ASTM OR ASME FOR THE SUCTION OUTLETS OF THE SWIMMING POOL, TODDLER POOL AND SPA FOR SINGLE FAMILY DWELLINGS PER ASSEMBLY BILL (AB) NO. 2977. (3162B) K. AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH UL 325. (R309.4) L. SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDED FOR HUMAN OCCUPANCY, UPON THE OWNER’S APPLICATION FOR A PERMIT FOR ALTERATIONS, REPAIRS, OR ADDITIONS, EXCEEDING ONE THOUSAND DOLLARS ($1,000). (R314.6.2) M. WHERE A PERMIT IS REQUIRED FOR ALTERATIONS, REPAIRS OR ADDITIONS EXCEEDING ONE THOUSAND DOLLARS ($1,000), EXISTING DWELLINGS OR SLEEPING UNITS THAT HAVE ATTACHED GARAGES OR FUEL-BURNING APPLIANCES SHALL BE PROVIDED WITH A CARBON MONOXIDE ALARM IN ACCORDANCE WITH SECTION R315.2. CARBON MONOXIDE ALARMS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS OBTAINED. (R315.2.2) N. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN AVERAGE ILLUMINATION OF 6 FOOT-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30 INCHES ABOVE THE FLOOR LEVEL. (R303.1) O. A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE P. PROVIDE (70) (72) INCH HIGH NON ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER RESISTANT MATERIALS FOR SHOWER ENCOSURE. (1209.2.2, 2406.4.5, R307.2, R308.4) 1. IN COMBUSTIBLE CONSTRUCTION, FIRE BLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. (R302.11) 2. IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET. DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. (R302.12) 1. AN APPROVED SMOKE ALARM SHALL BE INSTALLED IN EACH SLEEPING ROOM & HALLWAY OR AREA GIVING ACCESS TO A SLEEPING ROOM, AND ON EACH STORY AND BASEMENT FOR DWELLINGS WITH MORE THAN ONE STORY. SMOKE ALARMS SHALL BE INTERCONNECTED SO THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS WITHIN THE INDIVIDUAL DWELLING UNIT. IN NEW CONSTRUCTION SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER SOURCE FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH BATTERY BACK-UP AND LOW BATTERY SIGNAL. (R314) 2. AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. CARBON MONOXIDE ALARM SHALL BE PROVIDED OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S) AND ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. (R315) FIRE-RESISTANCE RATED CONSTRUCTION: FIRE PROTECTION: 1. PROVIDE 15" MINIMUM BETWEEN THE CENTER OF WATER CLOSET TO ANY SIDE WALL. (CALIF. PLUMB. CODE 407.6) 2. PROVIDE 24" CLEAR SPACE IN FRONT OF ANY WATER CLOSET. (CALIF. PLUMB. CODE 407.6) 3. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED NATURAL VENTILATION OR WITH MECHANICAL VENTILATION CAPABLE OF 50 CFM EXHAUSTED DIRECTLY TO THE OUTSIDE (R303.3) 4. HEATER SHALL BE CAPABLE OF MAINTAINING A MINIMUM ROOM TEMPERATURE OF 68°F AT A POINT 3 FEET ABOVE THE FLOOR AND 2 FEET FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE DESIGN TEMPERATURE. (R303.9) 1. PROVIDE A CLASS A, B OR C FIRE-RETARDANT ROOF COVERING PER SECTION 1505. 3. GLAZING IN THE FOLLOWING LOCATIONS SHALL BE SAFETY GLAZING CONFORMING TO THE HUMAN IMPACT LOADS OF SECTION 2406.1 (SEE EXCEPTIONS): A. FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BI-FOLD DOOR ASSEMBLIES. B. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE. C. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 1) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET. 2) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. 3) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. 4) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE GLAZING. G. GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 36 INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE OF STAIRWAYS, LANDINGS BETWEEN FLIGHTS OF STAIRS AND RAMPS. 5. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS WITH A MINIMUM FALL OF 6 INCHES WITHIN THE FIRST 10 FEET (1804.4). 6. DAMPPROOFING, WHERE REQUIRED, SHALL BE INSTALLED WITH MATERIALS AND AS REQUIRED IN SECTION R406.1. 8. BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. (502.1) 9. PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE PROVIDED IN THE LOCATIONS SPECIFIED PER SECTION R317.1 BY THE USE OF NATURALLY DURABLE WOOD OR WOOD THAT IS PRESERVATIVE-TREATED IN ACCORDANCE WITH AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE. PRESERVATIVES SHALL BE LISTED IN SECTION 4 OF AWPA U1. 10. PROVIDE ANTI-GRAFFITI FINISH WITHIN THE FIRST 9 FEET, MEASURED FROM GRADE, AT EXTERIOR WALLS AND DOORS. EXCEPTION: MAINTENANCE OF BUILDING AFFIDAVIT IS RECORDED BY THE OWNER TO COVENANT AND AGREE WITH THE CITY OF HATHORNEWOOD TO REMOVE ANY GRAFFITI WITHIN 7-DAYS OF THE GRAFFITI BEING APPLIED. (6306) INTERIOR ENVIRONMENT: BUILDING ENVELOPE: GENERAL NOTES: No. Description Date 1806 W 15th St & Unit #25/1/2025 DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:29 PM A304 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 WINDOW SPECIFICATIONS No. Description Date 1806 W 15th St & Unit #25/1/2025 WH W/D EXISTING FLOOR PLAN LEGEND EXISTING WALL DEMO AA CC GMGM (E) GAS METER EXISTING 1 STORY MAIN SFR 1,304 SF (E) FENCE TO BE DEMOLISHED (E) FENCE AND GATE TO BE DEMOLISHED N PROPERTY LINE 60'-0" PR O P E R T Y L I N E 10 2 ' - 0 " (E) WATER HEATER WH W 15TH ST DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:18 PM A100 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 EXISTING SITE PLAN No. Description Date SCALE: 3/16" = 1'-0" EXISTING SITE PLAN 1 1806 W 15th St & Unit #25/1/2025 WH W/D 32 ' - 4 " 3' - 8 " 3'-0" 5' - 1 1 " 9' - 5 1 / 2 " 8' - 3 " 8' - 8 1 / 2 " 3'-5 1/2"2'-9 1/2" 5'-3"6'-3 1/2"6'-1 1/2" 9' - 7 1 / 2 " 12 ' - 6 " 4' - 6 1 / 2 " 11'-3"10'-10" 20 ' - 2 " 6' - 1 1 " 9' - 8 " 7' - 0 1 / 2 " 10 ' - 6 1 / 2 " 7'-10 1/4"9'-3 1/4"7'-4 1/2"11'-10 1/2"5'-8 1/2" 42'-1" 34 ' - 2 " 8'-9" 9'-2" 5'-3"32'-8" EXISTING CONCRETE SLAB (E) WINDOW TO BE DEMOED D02 D06 9 9 16 D06 5 D06 9 6 14 D02 63 D62 D62 19 ' - 4 " 21'-3" 29'-3" 13 ' - 8 " 9'-0" 9'-0"7'-11" 6' - 6 " 10 ' - 6 " 14'-2" 11'-7" 10 ' - 8 " 1'-7"3' - 7 " 5'-6"2' - 5 " 3'-8" 9' - 6 " 4'-9 1/2"2'-3 1/2" 10 ' - 6 " 11'-7" 4' - 3 " 2'-6" (E) GARAGE EXISTING LIVING AND DINING (E) BEDROOM (E) BEDROOM(E) BEDROOM(E) KITCHEN (E) ENTRY (E) BATHROOM N (E) WALL CONVERT TO A DOOR OPENING EXISTING FLOOR PLAN LEGEND EXISTING WALL DEMO DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:18 PM A101 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 EXISTING FLOOR PLAN SCALE: 1/4" = 1'-0" EXISTING FLOOR PLAN & DEMO 1 No. Description Date 1 Revision 1 Date 1 1806 W 15th St & Unit #25/1/2025 W/D 5 3/8" / 1'-0"5 3/8" / 1'-0" 2'-0" 2' - 0 1 / 4 " 2'-0" 2'-0" EXISTING 1 STORY MAIN SFR 1,304 SF 4" / 1 ' - 0 " 4" / 1 ' - 0 " 4" / 1 ' - 0 " N 2' - 0 " (E) ADDITIONAL OVER-HANG TO BE REMOVED DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:18 PM A102 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 EXISTING ROOF PLAN No. Description Date SCALE: 1/4" = 1'-0" EXISTING ROOF PLAN 1 Jia Y. 1806 W 15th St & Unit #25/1/2025 TOP HEIGHT13' - 9" GARAGE FLOOR0' - 0" GARAGE PLATE 8' - 0" (E) FLOOR1' - 4" (E) PLATE9' - 4" (E) RIDGE16' - 1" (N) EXTERIOR FINISHES TO MATCH EXISTING STUCCO / TRIM IN TYPE & COLOR TO BE COMPATIBLE WITH THE PRIMARY RESIDENCE (OR APPD. SIM. V.I.F.) EXISTING ROOF (E) CONCRETE SLAB FINISH GRADE-0' - 4" GARAGE FLOOR 0' - 0" GARAGE PLATE 8' - 0" (E) FLOOR 1' - 4" (E) PLATE 9' - 4" (E) RIDGE16' - 1"EXISTING ROOF 2' - 4 3 / 4 " EXITING TRIM, SIDING AND SHUTTER ONLY ON THE WALLS FACING THE STREET FINISH GRADE-0' - 4" DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:19 PM A103 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 EXISTING ELEVATIONS No. Description Date SCALE: 1/4" = 1'-0" EXISTING EAST ELEVATION 1 SCALE: 1/4" = 1'-0" EXISTING WEST ELEVATION 2 1806 W 15th St & Unit #25/1/2025 TOP HEIGHT13' - 9" GARAGE FLOOR 0' - 0" GARAGE PLATE8' - 0" (E) FLOOR 1' - 4" (E) PLATE9' - 4" (E) RIDGE16' - 1"EXISTING SHINGLE ROOF FINISH GRADE-0' - 4" TOP HEIGHT 13' - 9" GARAGE FLOOR0' - 0" GARAGE PLATE8' - 0" (E) FLOOR1' - 4" (E) PLATE9' - 4" (E) RIDGE 16' - 1" EXISTING ROOF EXITING TRIM, SIDING AND SHUTTER ONLY ON THE WALLS FACING THE STREET FINISH GRADE-0' - 4" DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:20 PM A104 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 EXISTING ELEVATIONS No. Description Date SCALE: 1/4" = 1'-0" EXISTING NORTH ELEVATION 1 SCALE: 1/4" = 1'-0" EXISTING SOUTH ELEVATION 2 1806 W 15th St & Unit #25/1/2025 W/D GMGM (E) ELECTRICAL PANEL 200A (E) GAS METER (E) WATER HEATER (N)EXISTING CONDENSER UNIT RELOCATION (E) UTILITY POLE PP ACAC EP WH EXISTING 1 STORY MAIN SFR 1,304 SF 1806 W. 15TH ST. SANTA ANA CA. 92706 20 ' - 5 " 22 ' - 7 " 9' - 0 " (E) ADDITIONAL OVER-HANG TO BE REMOVED EXISTING GARAGE (451 SF) (E) 5'-9" CHAIN LINK FENCE (E) CONCRETE (E) GRASS (E) GRASS 5'-2" 8'-9" 9'-2" 60.00' Property line 10 2 . 0 0 ' P r o p e r t y l i n e 10 2 . 0 0 ' P r o p e r t y l i n e 60.00' Property line NEW PROPOSED ONE STORY ATTACHED ADU (146.56 SF PARTIAL CONVERSION OF THE EXISTING + 335.02 SF ADDITION) TOTAL 491.08 SF 6' - 1 1 1 / 2 " 5' - 3 1 / 2 " WH(N)CONDENSER UNIT ACAC (N) HEAT PUMP WATER HEATEREA S E M E N T 6' - 0 " (E) HARDSCAPE N 7 1 / 4 " W 15TH ST (E) GRASS (N) CONCRETE 5% 5% 5% 5% 5% 2% 2% 5% 5%5%5% (N) ADU (E) DWELLING SITE LEGEND (E) PROPERTY LINE D GMGM (E) ELECTRICAL PANEL (E) GAS METER (E) WATER HEATER (E) CONDENSER UNIT (E) WATER METER (E) UTILITY POLE (E) CLEANOUT P P A C EP WH WM GRASS/TURF CONCRETE EASEMENT AREA DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:20 PM A110 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 PROPOSED SITE PLAN No. Description Date SCALE: 3/16" = 1'-0" SITE PLAN 1 1806 W 15th St & Unit #25/1/2025 WH W/ D W/D . D 2 2. . . . . . . . . GF C I GF C I GFCI GFCIGFCIGFCIGFCI GF C I . 42" WP GFI . (N) LIVING (N) VAULTED (N) BATH PA N T R Y (E) BEDROOM (N ) C L O S E T 7'-8 1/2" 5' - 5 " 10 ' - 6 " 3' - 0 " 4' - 3 " 4' - 0 " 4'-0" VALETED CEILING 3'-0" 5' - 1 0 " NEW CONCRETE SLAB EXTENSION EXISTING CONCRETE SLAB 5' - 3 1 / 2 " 7' - 2 " (E) FLOOR PLAN (NOT PART OF THE SCOPE) 3' - 8 1 / 2 " 8' - 1 " 5' - 2 1 / 2 " 4'-9"(N) OPENING TO THE EXISTING WALL 20'-1" 6' - 8 1 / 2 " 6' - 8 1 / 2 " 4' - 8 " 3'-5 1/2"2'-11"8'-6 1/2"4'-4" D06 D02 D62 D03 W40 W274D69 W73 D05 D05 (N) HEAT PUMP WATER HEATER WH (N) 22"X30" MIN ATTIC ACCESS 2'-7" 30" MIN. 24 " M I N N (N)EXISTING CONDENSER UNIT RELOCATION ACAC (N)CONDENSER UNIT ACAC 2' - 4 " 1' - 7 " 1' - 7 " EGRESS DOOR SHALL NOT BE MORE THAN 1 1/2" LOWER THAN THE TOP OF THE THRESHOLD EGRESS DOOR SHALL NOT BE MORE THAN 1 1/2" LOWER THAN THE TOP OF THE THRESHOLD CD OCCUPANT SENSOR MIN. EXHAUST RATE: GAS RANGE 280 CFM ELECTRIC RANGE 160 CFM NO GAS HOOK UP AT STOVE (ELECTRIC RANGE) D06 W40 - --- 1 A111 2 A111 IAQ FAN & BATHROOM EXHAUST MIN 50 CFM, MAX. 1 SONES. DUCTED TO OUTSIDE AND CONTROLLED BY HUMIDSTAT. THE FANS STAY ON THE SWITCH IDENTIFYING THIS AS THE WHOLE HOUSE IAQ FAN AND TO RUN AT ALL TIMES THE HOUSE IS OCCUPIED 2' - 6 1 / 4 " 5' - 0 " 2' - 1 1 1 / 2 " - --- 1 A111 LA N D I N G NOTE: FLOOR PLAN LEGEND ENERGY STAR EXHAUST MIN 50 CFM DUCTED TO OUTSIDE AND CONTROLLED BY HUMIDISTAT SMOKE DETECTOR/CARBON MONOXIDE EXISTING WALL EXTERIOR LIGHT FIXTURE NEW WALL 1-HR FIRE RATED WALL LED DOWNLIGHT FIXTURE (E) PROPERTY LINE AFCI DUPLEX GFCI/AFCI DUPLEX WEATHERPROOF GFCI/AFCI DUPLEX AFCI DUPLEX @ 42" ABOVE FINISHED FLOOR ENERGY STAR EXHAUST 100 CFM INSULATION PER T24 *UL U305 FIRE RATING STC 5/8" GYPSUM BOARD TYPE X EACH SIDE, SCREW 8" O.C. END JOINTS RESILIENT CLIP AT EA. STUD OR RESILIENT CHANNELS -- ONE SIDE 2X WOOD STUD NOTE: 1 HOUR SEPARATION GOES FROM FOUNDATION TO THE UNDERSIDE OF THE ROOF SHEATING DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 12/6/2024 4:23:37 PM A111 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 PROPOSED 1ST FLOOR PLAN SCALE: 1/4" = 1'-0" PROPOSED 1ST FLOOR PLAN 1 12" = 1'-0" 1- HOUR EXTERIOR STUCCO WALL No.Description Date DOOR SCHEDULE Type Mark Width Height Count Type Comments U-FACTOR Phase Created Description D02 2' - 8"6' - 8"1 SWING New Construction D03 2' - 8"6' - 8"1 BI-FOLD New Construction D05 2' - 10"8' - 0"2 OPENING New Construction D06 2' - 0"6' - 8"1 CLOSET SWING DOOR New Construction D62 3' - 0"6' - 8"1 SWING 0.2 New Construction D69 5' - 8"6' - 8"1 DOUBLE SWING 0.2 New Construction WINDOW SCHEDULE Type Mark Width Height Head Height Sill Height Count Type Comments Description SHGC U-Factor Phase Created W40 3' - 0"3' - 0"6' - 8"3' - 8"2 HUNG 0.23 0.3 New Construction W73 5' - 0"5' - 0"6' - 8"1' - 8"1 HUNG 0.23 0.3 New Construction W274 5' - 0"3' - 10"6' - 8"2' - 10"1 HUNG 0.23 0.3 New Construction NEWLY CONSTRUCTED DWELLINGS SHALL COMPLY WITH AGING-IN- PLACE AND FALL PREVENTION (CRC R327): 1. AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH REINFORCEMENT FOR GRAB BARS, WHERE THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL COMPLY WITH CRC R327.1.1. PROVIDE CONSTRUCTION DETAIL SHOWING COMPLIANCE WITH THIS REQUIREMENT. 2. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS SHALL BE LOCATED NO MORE THAN 48" MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15" MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. CRC R327.1.2 3. DOORBELL BUTTONS SHALL NOT BE INSTALLED MORE THAN 48" ABOVE EXTERIOR FLOOR OR LANDING. CRC R327.1.4 INDOOR LIGHTING CONTROLS NOTE: 1. ADDS AUTO-OFFCONTROLS FOR LIGHTING IN DRAWERS AND CABINETS 2. UNDERSHELF, DISPLAY CABINETS, SWITCHED OUTLETS CONTROLLED SEPARATE FROM CEILING LIGHTING. 3. LIGHTING IN HAVITABLE SPACES SHALL HAVE ACCESSIBLE WALL- MOUNTED DIMMING CONTROLS. 1" = 1'-0" 1-HR, FIRE RATING INTERIOR WALL 2 1 NOTE: SEE SHEET A304 AND A305 FOR DOOR AND WINDOW SPECIFICATION AGING IN PLACE REQUIREMENTS ON SHEET G005 1806 W 15th St & Unit #25/1/2025 W/D 2 A210 1 A210 4" / 1'-0" 4" / 1'-0" 4" / 1'-0" 4" / 1'-0" 4" / 1 ' - 0 " 4" / 1 ' - 0 " 5 3/8" / 1'-0"5 3/8" / 1'-0" N 4" / 1'-0" 8'-2" 3'-0" 5' - 0 " 34'-11" --- -1 A131 NEW CLASS "A" ASPHALT SHINGLE ROOF ESR-1475 MATCH WITH EXISTING (CONTRACTOR TO VERIFY) SEE SHEET A302 FOR SPEC LOUVER STATIC VENT LOUVER STATIC VENT (E) CHIMNEY EAVE VENT W.U.I. APPROVAL SEE SHEET A305 FOR SPECIFICATION EAVE VENT W.U.I. APPROVAL SEE SHEET A305 FOR SPECIFICATION ATTIC AREA 216.15 SF VAULTED AREA 266 SF (E) ROOF ROOF LEGEND ATTIC AREA: AREA 216.15 SF (E) PROPERTY LINE DEMO ROOF (N) ROOF (E) 1 HR RATED EAVE VAULTED AREA : AREA 266 SF APPROVED ROOF COVERING SEE SHEET A131 & A302 2X BLOCKING 2X FRAMING @ 24" O/C MAX. METAL DRIP EDGE 2X FASCIA TO BE COVERED W. CEMENT BD. 7/8" STUCCO IGNITION RESISTIVE CONSTRUCTION PER COUNTY BUILDING CODE SEC. 704A.3 NOTE: ALL JOINTS MUST BE TIGHT FITTING AND CAULKED APPROVED ROOF COVERING SEE SHEET A131 & A302 AREA VENT AREA @150/S.F.VENT TYPE NFA QTY TOTAL VENT AREA TOTAL VENT AREA PROVIDED: ATTIC AREA: 4x60= 240 SQ.IN > 207 SQ.IN OK VAULTED AREA: 40x75= 300 SQ.IN > 255 SQ.IN OK 216.15 S.F.1.44 S.F.60 SQ.IN.240 SQ.IN.LOUVER STATIC VENT EAVE VENT (W.U.I.) APPROVED VENTILATION TABLE VENT AREA @150/S.F. X144 SQ.IN 207.5 SQ.IN. SPACE ATTIC SPACE 4 VAULTED SPACE/ ENCLOSED RAFTER 266 S.F.1.77 S.F.255 SQ.IN. 75 SQ.IN.4 300 SQ.IN. LOUVER STATIC VENT EAVE VENT 7.5"x14" W.U.I. SEE SHEET A305 FOR ROOF VENT SPECIFICATION DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 12/6/2024 4:13:34 PM A131 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 ROOF PLAN SCALE: 1/4" = 1'-0" PROPOSED ROOF PLAN 1 No.Description Date 1778.35 SQFT 1" = 1'-0" 1-HR, FIRE RATING VAULTED CEILING & VENTILATION 1 1/4" = 1'-0" VENTILATION CALC 1806 W 15th St & Unit #25/1/2025 GRADE-0' - 8" TOP HEIGHT 13' - 9" GARAGE FLOOR0' - 0" GARAGE PLATE8' - 0" (E) FLOOR 1' - 4" (E) PLATE 9' - 4" (E) RIDGE16' - 1" (N) EXTERIOR FINISHES TO MATCH EXISTING STUCCO / TRIM IN TYPE & COLOR TO BE COMPATIBLE WITH THE PRIMARY RESIDENCE (OR APPD. SIM. V.I.F.) NEW SHINGLE ROOF EXISTING ROOF (E) CONCRETE SLAB (N) CONCRETE LANDING EXTENSION (N) UNDERFLOOR ACCESS 1'-6" 11 " 2'-0" 1' - 6 "FINISH GRADE-0' - 4" ADU UNDERFLOOR AREA = 481.58 SQ. FT. 481.58 SQ. FT. / 150 = 3.21 SQ. FT. 3.21 SQ. FT. X 144 SQ. IN. = 462.24 SQ.IN. REQUIRED VENTILATION = 462.24 SQ.IN. PROVIDED ROOF EXHAUST: MASTER FLOW AUTOMATIC OPEN/CLOSE FOUNDATION VENT NFA = 57 SQ IN. X 9 = 513 SQ.IN. THE TOTAL PROVIDED INTAKE/EXHAUST > REQUIRED 513 >462.24 SQ.IN. MASTER FLOW AUTOMATIC OPEN/CLOSE FOUNDATION VENT NET FREE AREA = 57 SQ.IN. UNDERFLOOR VENTILATION CALCULATIONS DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:22 PM A200 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 ELEVATIONS 1/4" = 1'-0" EAST ELEVATION No. Description Date 1/4" = 1'-0" WEST ELEVATION 1806 W 15th St & Unit #25/1/2025 TOP HEIGHT13' - 9" GARAGE FLOOR0' - 0" GARAGE PLATE 8' - 0" (E) FLOOR 1' - 4" (E) PLATE 9' - 4" (E) RIDGE16' - 1" (N) EXTERIOR FINISHES TO MATCH EXISTING STUCCO / TRIM IN TYPE & COLOR TO BE COMPATIBLE WITH THE PRIMARY RESIDENCE (OR APPD. SIM. V.I.F.) NEW SHINGLE ROOF EXISTING ROOF FINISH GRADE-0' - 4" GRADE-0' - 8" TOP HEIGHT13' - 9" GARAGE FLOOR 0' - 0" GARAGE PLATE8' - 0" (E) FLOOR1' - 4" (E) PLATE9' - 4" (E) RIDGE16' - 1" (N) EXTERIOR FINISHES TO MATCH EXISTING STUCCO / TRIM IN TYPE & COLOR TO BE COMPATIBLE WITH THE PRIMARY RESIDENCE (OR APPD. SIM. V.I.F.) NEW SHINGLE ROOF EXISTING ROOF (N) CONCRETE SLAB EXTENSION 1'-6" 11 " 1'-6" 11 " 1'-6" 11 " 3'-0" FINISH GRADE-0' - 4" DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:22 PM A201 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 ELEVATIONS No. Description Date 1/4" = 1'-0" SOUTH ELEVATION 1/4" = 1'-0" NORTH ELEVATION 1806 W 15th St & Unit #25/1/2025 GRADE -0' - 8" (E) FLOOR1' - 4" (E) PLATE9' - 4" (E) RIDGE 16' - 1" NEW SHINGLE ROOF VALTED CEILING (N) KITCHEN(N) BATHROOM(N) LAUNDRYR15 INSUL. WALL TO ROOF PER STRUCTURAL *NOTE* OWNER OR CONTRACTOR TO VERIFY (E) FOUNDATION & INSPECT FOR DAMAGE. IF DAMAGED, FOUNDATION & FOOTINGS SHALL BE REPAIRED/REPLACED, STRUCTURAL PLAN SHALL BE REVISED TO SHOW THE REPLACEMENT OF PORTION OF EXISTING FOOTING WITH NEW FOOTING AND THE REVISED PLAN IS REQUIRED TO BE SUBMITTED AS A REVISION TO CITY BUILDING AND SAFETY DIVISION FOR REVIEW AND APPROVAL 8' - 0 " 6' - 8 " R30 INSUL. C.J. PER STRUCTURALR.R. PER STRUCTURAL 8" 1' - 6 " 2' - 0 " FINISH GRADE -0' - 4" (N) WOOD LANDING AND STAIRS R15 INSUL. GRADE-0' - 8"GARAGE FLOOR 0' - 0" (E) FLOOR1' - 4" (E) PLATE9' - 4" (E) RIDGE16' - 1" 8' - 0 " 8' - 0 " (E) WINDOW TO BE DEMOED VALTED CEILING (N) LIVING (N) BATHROOM (E) BEDROOM R30 INSUL. C.J. PER STRUCTURALR.R. PER STRUCTURAL WALL TO ROOF PER STRUCTURAL HOLD DOWN/ANCHOR PER STRUCTURAL (N) FOOTING PER STRUCTURAL 11 ' - 6 1 / 2 " 1' - 8 " *NOTE* OWNER OR CONTRACTOR TO VERIFY (E) FOUNDATION & INSPECT FOR DAMAGE. IF DAMAGED, FOUNDATION & FOOTINGS SHALL BE REPAIRED/REPLACED, STRUCTURAL PLAN SHALL BE REVISED TO SHOW THE REPLACEMENT OF PORTION OF EXISTING FOOTING WITH NEW FOOTING AND THE REVISED PLAN IS REQUIRED TO BE SUBMITTED AS A REVISION TO CITY BUILDING AND SAFETY DIVISION FOR REVIEW AND APPROVAL 8" 1' - 6 " 1' - 6 " DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 12/6/2024 4:15:45 PM A210 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 SECTIONS No.Description Date NTS _DETAIL - STAIR & HANDRAIL 1/4" = 1'-0" Section 1 1/4" = 1'-0" Section 2 1 EXTERIOR SECTION WALL DEATIL 2 WEEP SCREED DETAIL 3 1806 W 15th St & Unit #25/1/2025 DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:24 PM A301 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 SPECIFICATIONS No. Description Date 1806 W 15th St & Unit #25/1/2025 DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 12/6/2024 4:18:36 PM A302 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 SPECIFICATIONS No.Description Date 1806 W 15th St & Unit #25/1/2025 DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 12/6/2024 10:56:13 AM A303 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 SPECIFICATIONS No.Description Date 1 Revision 1 Date 1 1806 W 15th St & Unit #25/1/2025 DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:37 PM A305 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 DOOR SPECIFICATIONS No. Description Date BIFOLD LOUVERED DOOR 1806 W 15th St & Unit #25/1/2025 DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 12/6/2024 4:20:23 PM A306 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 ROOF VENT SPECIFICATION No.Description Date 1806 W 15th St & Unit #25/1/2025 4 4 No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # S.S. S.S. N.T.S. 23-544 AD D R E S S : 18 0 6 W 1 5 T H S T . , SA N T A A N A , C A 9 2 7 0 6 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 10/21/2023 12/6/2024 GD1 GE N E R A L DE T A I L S 1806 W 15th St & Unit #25/1/2025 DO NOT cut, notch or drill holes in headers or beams except as indicated in illustrations and tables. 1.3E TimberStrand®LSL allowed hole zone dd Microllam®LVL and Parallam® PSL allowed hole zone middle 13 span 1.3E TimberStrand® LSL hole zone Microllam®LVL and Parallam® PSL hole zone 2 x diameter of the largest hole (minimum) d 13 depth 1" 2" 13 4" Maximum Round Hole Size Header or Beam Depth 43 8" 714"- 20" 512" See illustration for Allowed Hole Zone ALLOWABLE HOLES - Headers and Beams General Notes No holes in headers or beams in plank orientation. Allowed hole zone suitable for headers and beams with uniform loads only. Round holes only No holes in cantilevers. Other Trus Joist® Beams No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # S.S. S.S. N.T.S. 23-544 AD D R E S S : 18 0 6 W 1 5 T H S T . , SA N T A A N A , C A 9 2 7 0 6 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 10/21/2023 12/6/2024 GD2 GE N E R A L DE T A I L S 1806 W 15th St & Unit #25/1/2025 No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # S.S. S.S. N.T.S. 23-544 AD D R E S S : 18 0 6 W 1 5 T H S T . , SA N T A A N A , C A 9 2 7 0 6 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 10/21/2023 12/6/2024 GN1 GE N E R A L NO T E S 1806 W 15th St & Unit #25/1/2025 No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # S.S. S.S. N.T.S. 23-544 AD D R E S S : 18 0 6 W 1 5 T H S T . , SA N T A A N A , C A 9 2 7 0 6 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 10/21/2023 12/6/2024 GN2 GE N E R A L NO T E S 1806 W 15th St & Unit #25/1/2025 FOUNDATION PLAN SCALE: 1/4" = 1' 1. PROVIDE A WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MINIMUM 4" ABOVE THE EARTH OR 2" ABOVE PAVED AREAS. 2. HOLD-DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. 3. HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE WASHERS; AND HOLD-DOWNS SHALL BE TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE STEEL PLATE WASHERS IN ACCORDANCE WITH TABLE 2306.5 OF THE LABC. 4. FOUNDATION ANCHOR BOLTS IN WALLS WITH LATERAL LOADS GREATER THAN 300 POUNDS/FOOT SHALL HAVE AN APPROVED PLATE WASHER UNDER EACH NUT; AND THE NUTS SHALL BE TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. 5. UNO THE FOUNDATION BOLTS SHALL BE 5/8" DIA. WITH 3"x3"x1/4" PLATE WASHERS EMBEDDED AT LEAST 9 INCHES INTO THE CONCRETE (OR) MASONRY FOUNDATION SPACED NOT MORE THAN 6 FEET APART. 6. MIN 2 BOLTS PER PIECE OF SILL PLATE AND ONE LOCATED WITHIN 12" AND NOT LESS THAN 7 BOLT DIAMETER OR 4-3/8" OF EACH END OF EACH SILL PLATE. 7. FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. 8. ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED. PLATE WASHERS ARE REQUIRED FOR ALL HOLDOWNS. 9. ALL FOUNDATION EXCAVATIONS MUST BE OBSERVED AND APPROVED BY THE PROJECT ENGINEERING GEOLOGIST AND/OR PROJECT GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT OF REINFORCING STEEL. 10. IF ADVERSE SOIL CONDITIONS ARE IN ENCOUNTERED, A SOILS INVESTIGATION REPORT MAY BE REQUIRED. 11. PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIAMETER AND FULL DIAMETER FOR SMOOTH SHANK PORTION. 12. FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. NOTES: DENOTES NEW FOOTING LEGEND: DENOTES EXISTING FOOTING 4x4 POST INTERIOR WALL (U.N.O.) SHEAR WALL PER PLAN 4x6 POST EXTERIOR WALL (U.N.O.) FLOOR SHEATHING: 3/4" T&G PLYWOOD STANDARD PS I-95 INDEX 40/20 DOUGLAS FIR-LARCH W/10d COMMON NAILS @ 6"_6"_10" O.C. No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # AD D R E S S : 18 0 6 W 1 5 T H S T . , SA N T A A N A , C A 9 2 7 0 6 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 S.S. S.S. 23-544 10/21/2023 12/6/2024 1/4” = 1’-0” S1 FO U N D A T I O N PL A N 1806 W 15th St & Unit #25/1/2025 ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE JOINTS OCCURRING IN BRACED WALL PANELS SOLID BLOCKING SHALL BE PROVIDED AT ALL HORIZONTAL COMMON NAILS OR GALVANIZED BOX. 1" Ø BOLT - 3.5"x3.5"x3/8" b) 3 x STUDS AND BLOCKS BETWEEN ADJACENT PANELS c) 1/2" EDGE DISTANCE FOR PLYWOOD BOUNDARY NAILING d) ALL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED. e) SQUARE PLATE WASHERS SHALL BE USED WITH ANCHOR BOLTS 5/8" Ø BOLT - 3"x3"x1/4" 7/8" Ø BOLT - 3"x3"x5/16" a) 3 x FOUNDATION SILL PLATES ALL SHEAR WALLS WITH A SHEAR VALUE GREATER THAN 300 lb/ft SHOULD BE PROVIDED: 3/4" Ø BOLT - 3"x3"x5/16" d) STAGGER NAILS IF NAIL SPACING IS LESS THAN 2" O.C. 2. DOUBLE JOISTS ARE REQUIRED UNDER PARALLEL BEARING PARTITIONS. 3. AN AITC CERTIFICATE OF INSPECTION FOR ALL GLU-LAM BEAMS INCLUDING PARALLAM BEAMS SHALL BE SUBMITTED TO THE BUILDING AND SAFETY DEPT. PRIOR TO ERECTION. 4. GLUE LAM BEAMS MUST BE FABRICATED IN A LADBS LICENSED SHOP. IDENTIFY GRADE SYMBOL AND LAMINATION SPECIES PER T 5A, 2005 NDS SUPP. 6. SHOP WELDS MUST BE PERFORMED IN A LADBS LICENSED FABRICATORS SHOP. 8. ALL WOOD MEMBERS MUST BE GRADE MARKED WITH GRADE AND SPECIES. 9. BEARING WALL STUDS CANNOT BE NOTCHED MORE THAN 25% OF THEIR WIDTH. BORED HOLES CANNOT HAVE A DIAMETER GREATER THAN 40% OF THE STUD WIDTH 10. PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIAMETER AND FULL DIAMETER FOR SMOOTH SHANK PORTION. 11. STRUCTURAL OBSERVATION IS REQUIRED FOR ALL PLYWOOD SHEAR WALLS WITH A DESIGN LOAD OVER 300 PLF. 12. ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 14. EXTERIOR STAIRS AND BALCONIES MUST BE POSITIVELY ATTACHED TO THE STRUCTURE WITHOUT THE USE OF TOE NAILS OR NAILS IN WITHDRAWAL. 16. CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/ COMPONENT LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE LADBS INSPECTORS AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT PER SEC 1706.1 17. CONTINUOUS SPECIAL INSPECTION REQUIRED BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING, CONCRETE STRENGTH f'c>2500 PSI, HIGH STRENGTH BOLTING, SPRAYED-ON FIREPROOFING, ENGINEERED MASONRY, HIGH-LIFT GROUTING, PRE-STRESSED CONCRETE, HIGH LOAD DIAPHRAGMS AND SPECIAL MOMENT-RESISTING CONCRETE FRAMES. 7. LADBS LICENSED FABRICATOR IS REQUIRED FOR STRUCTURAL STEEL. 18. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS, AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING, AND OTHER FASTENING TO COMPONENTS OF THE SEISMIC FORCE RESISTING SYSTEM. SPECIAL INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED WHERE THE FASTENER SPACING OF THE SHEATHING IS MORE THAN 4 INCHES ON CENTER. 13. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.7 15. ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED. 1. ALL WALLS OVER 10' IN HEIGHT TO BE 2x6 @16" O.C. FRAMING. NOTES: FRAMING MEMBERS LEGEND: ROOF SHEATHING: 5/8" CDX PLYWOOD STANDARD PS I-95 INDEX 32/16 DOUGLAS FIR-LARCH W/10d COMMON NAILS @ 6"_6"_10" O.C. 19. FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. 20. FIELD WELDING TO BE DONE BY WELDERS CERTIFIED BY THE LADBS. CONTINUOUS INSPECTION IS REQUIRED, 21. A COPY OF THE LOS ANGELES RESEARCH REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE. ROOF FRAMING PLAN SCALE: 1/4" = 1' 380 650 498 PLATE TO BLKG. REQUIREMENTS SDS 1/4"x 6 SDS 1/4"x 6 SDS 1/4"x 6 SHEAR WALL SCHEDULE 12" O.C. PANEL NAILING 12" O.C. 12" O.C. 12" O.C. 10d @215/32" PLYWOOD 15/32" PLYWOOD STRUCTURAL 1 STRUCTURAL 1 STRUCTURAL 1 15/32" PLYWOOD4 3 2" O.C. 10d @ 10d @ 3" O.C. 4" O.C. OF SHEAR STRUCTURAL 1 WALL MATERIAL 15/32" PLYWOOD DESCRIPTION TYPE 1 PERIMETER 6" O.C. 10d @ 10d @ 12" O.C. OR LPT4 @ 8" O.C. 8" O.C. OR 10" O.C. OR LPT4 @ 10" O.C. LPT4 @ 12" O.C. 10d @ 10d @ A35 @ A35 @ @ 4" O.C. @ 8" O.C. @ 6" O.C. REQUIREMENTS BLKG. TO PLATE 16" O.C. OR CONNECTION LPT4 @ 16" O.C. 10d @ FIELD A35 @ A35 @ CONNECTION @ 6" O.C. 20d NAILS OR 5/8" Ø @ 24" O.C. 3/4" Ø @ 32" O.C. 3/4" Ø @ 32" O.C. 5/8" Ø @ 32" O.C. 3/4" Ø @ 48" O.C. OR OR 9" 9" 9" 9" 9" 3/4" Ø @ 6'-0" O.C. 5/8" Ø @ 48" O.C. 5/8" Ø @ 32" O.C. ANCHOR BOLTS FOUND CONN. SILL PLATE TO OR 9" 255 ANCHOR EMB. BOLTS 9" 9" ALLOWABLE SHEAR LOAD PLF No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # AD D R E S S : 18 0 6 W 1 5 T H S T . , SA N T A A N A , C A 9 2 7 0 6 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 S.S. S.S. 23-544 10/21/2023 12/6/2024 1/4” = 1’-0” S2 RO O F F R A M I N G PL A N 1806 W 15th St & Unit #25/1/2025 No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # S.S. S.S. N.T.S. 23-544 AD D R E S S : 18 0 6 W 1 5 T H S T . , SA N T A A N A , C A 9 2 7 0 6 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 10/21/2023 12/6/2024 S3 DE T A I L 1806 W 15th St & Unit #25/1/2025 No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # S.S. S.S. N.T.S. 23-544 AD D R E S S : 18 0 6 W 1 5 T H S T . , SA N T A A N A , C A 9 2 7 0 6 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 10/21/2023 12/6/2024 S4 DE T A I L 1806 W 15th St & Unit #25/1/2025 DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:46 PM G002 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 CAL GREEN - LOS ANGELES No. Description Date 1806 W 15th St & Unit #25/1/2025 DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:45 PM G001 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 GENERAL NOTES THE PROJECT SHALL DEMONSTRATE A 2-% REDUCTION IN WATER USE BY SPECIFYING PLUMBING FIXTURES AND FIXTURES THAT MEET THE FLOW RATES LISTED BELOW, OR THROUGH A CALCULATION SHOWING A 20% REDUCTION FROM BASELINE VALUES LISTED IN CALGREEN TABLE 4.303.1. SHOWERHEADS:1.8 GALLONS PER MINUTE (GPM) 1* @80 psi LAVATORY FAUCET- RESIDENTIAL: 1.2 GPM @60 psi KITCHEN FAUCETS:1.8 GPM @60 psi WATER CLOSETS:1.28 GALLONS PER FLUSH 2* URINALS:0.125 GALLON PER FLUSH METERING FAUCETS:0.2 GALLON PER CYCLE NOTES: 1. THE COMBINED FLOW RATE OF MULTIPLE SHOWER HEADS SHALL NOT EXCEED THE MAXIMUM FLOW RATE, OR THE SHOWER SHALL BE DESIGNED TO PERMIT ONE SHOWERHEAD TO BE IN OPERATION AT A TIME. 2. THE EFFECTIVE FLUSH VOLUME FOR DUAL-FLUSH TOILETS IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO REDUCED FLUSHES AND ONE FULL FLUSH. ELECTRICAL NOTES: PER 2022 CALIFORNIA ELECTRICAL CODE A. PANEL LOCATIONS PANELS SHALL NOT BE LOCATED IN THE VICINITY OF EASILY IGNITABLE MATERIAL, SUCH AS CLOTHES CLOSETS, OR IN BATHROOMS (CEC 240-24(D)). B. NON-METALLIC SHEATHED CABLE (CEC 334) NON-METALLIC SHEATHED CABLE SHALL BE: 1. PROTECTED BY RIGID METAL CONDUIT, INTERMEDIATE METAL CONDUIT,ELECTRICAL METALLIC TUBING, SCHEDULE 80 PVC CONDUIT, PIPE, OR OTHER MEANS WHEN CABLE IS EXPOSED OR SUBJECT TO PHYSICAL DAMAGE. (CEC 334.15(B)) 2. PROTECTED BY A 1.16 INCH STEEL PLATE OR SLEEVE, OR BE NOT LESS THAN 1-1/4 INCH FROM THE NEAREST EDGE OF THE FRAMING MEMBER, WHEN INSTALLED THROUGH FRAMING MEMBERS. STEEL PLATES OR SLEEVES ARE REQUIRED ON ALL DOUBLE SHEAR WALLS WHEN CABLE IS INSTALLED EITHER THROUGH OR PARALLEL TO FRAMING MEMBERS (CEC 334.17). 3. PROTECTED BY GUARD STRIPS WITHIN 6FT OF AN ATTIC ACCESS WHEN NO PERMANENT STAIRS OR LADDERS ARE PROVIDED. (CEC 334.23, 320.23) 3. PROTECTED BY GUARD STRIPS IN THE ENTIRE ATTIC WHEN PERMANENT STAIRS OR LADDERS ARE PROVIDED. ACCESS PANELS OR DOORS FROM THE SECOND FLOOR INTO THE ATTIC ARE CONSIDERED PERMANENT ACCESS AND GUARD STRIPS ARE REQUIRED IN THE ENTIRE ATTIC. 5. HAVE A BENDING RADIUS NOT LESS THAN 5 TIMES THE DIAMETER OF THE CABLE (CEC 334.24). 6. SUPPORTED AT INTERVALS NOT EXCEEDING 4-1/2 FEET AND WITHIN 12" OF EVERY OUTLET BOX, JUNCTION BOX, CABINET OR FITTING (CEC 334.30). C. CIRCUITS AND RECEPTACLES 1.RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6 FT. FROM AN OUTLET, INCLUDING ANY WALL SPACE 2 FT. WIDE OR GREATER. NOTE: A FIXED PANEL OF A SLIDING GLASS DOOR IS CONSIDERED WALL SPACE. 2. IN KITCHENS, BREAKFAST ROOMS, PANTRIES AND DINING ROOMS A MINIMUM OF 2-20A CICUITS SHALL BE PROVIDED (CEC 210.11 (C)(1)). COUNTER SPACE RECEPTACLES SHALL BE GFCI (CEC 210.8 (A)) AND INSTALLED: - AT EACH WALL COUNTER SPACE THAT IS 12 IN. OR GREATER (CEC 210.52 (C)(1)); - NO MORE THAN 48 IN. OC. (CEC 210.52 (C)(1)); - MAXIMUM 24 IN. FROM THE END OF THE COUNTER (CEC 210.52 (C)(1)); - MAXIMUM 20 IN. ABOVE COUNTER SURFACE (CEC 210.52 (C)(3)); - ON ISLAND COUNTER SPACES (ONE RECEPTACLE MIN.) NOT MORE THAN 12 IN. BELOW COUNTER SURFACE (CEC 210.52 (C)(3) EXCEPTION). AN ISLAND WITH LESS THAN 12" BEHIND A RANGE TOP OF SINK IS CONSIDERED AS DIVIGING THE COUNTERTOP INTO TWO SEPARATE SPACES (CEC 210.52 (C)(3)). - ON PENINSULAR COUNTER SPACES (ONE RECEPTACLE MIN.) NOT MORE THAN 12 IN. BELOW COUNTER SURFACE (CEC) 210.52 (C)(3) EXCEPTION)); 3. BATHROOMS SHALL HAVE A SEPARATE 20A CIRCUIT (CEC 210.11 (C)(3)) WITH AT LEAST ONE GFCI WALL RECEPTCLE WITHIN 36 IN. OF EACH BASIN (CEC 210.8 (A)(1); CEC 210.52 (D)). 4. LAUNDRY ROOMS SHALL HAVE A SEPARATE 20A CIRCUIT WITH AT LEAST ONE RECEPTACLE SHALL BE PROVIDED (CEC 210.11 (C)(2)). ALL RECEPTACLES WITHIN 6 FT. OF A SINK SHALL BE GFCI (CEC 210.52(F)). 5. IN GARAGES, AT LEAST ONE GFCI RECEPTACLE SHALL BE PROVIDED (CEC 210.52 (G)). ALL OTHER GARAGE RECEPTACLES EXCEPT THOSE DEDICATED TO AN APPLIANCE OR THAT ARE NOT READILY ACCESSIBLE SHALL BE GFCI. (CEC 210.8 (A)(2)) PER 2022 CALIFORNIA ELECTRICAL CODE 6. IN HALLWAYS OF 10 FT. OR MORE IN LENGTH, AT LEAST ONE RECEPTACLE SHALL BE PROVIDED (CEC 210.52 (H)). 7. OUTDOOR OUTLETS SHALL BE GFCI (CEC 210.8 (A) (3)). ONE OUTLET SHALL BE INSTALLED AT THE FRONT OF THE DWELLING AND ONE AT THE REAR OF THE DWELLING. RECEPTACLES SHALL BE ACCESSIBLE AT GRADE LEVEL AND NOT MORE THAN 6-1/2 FT. ABOVE GRADE (CEC 210.52 (E)). 8. ALL CRAWL SPACE RECEPTACLES SHALL BE GFCI (CEC 210.8(A)(4)). 9. ALL UNFINISHED BASEMENT RECEPTACLES SHALL BE GFCI UNLESS THEY ARE NOT READILY ACCESSIBLE OR ARE SERVICE A DEDICATED APPLIANCE (CEC 210.8 (A)(5)). 10. ALL RECEPTACLES WITHIN 6FT. OF A WET BAR SHALL BE GFCI (CEC 210.8(A)(7)). 11. ALL RECEPTACLES ON 15A OR 20A BRANCH CIRCUITS THAT SUPPLY FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY COMBINATION-TYPE ARC-FAULT CIRCUIT INTERRUPTERS (AFCI), INCLUDING SWITCHED OUTLETS (CEC 210.12(B)). 12. ALL RECEPTACLES SERVING APPLIANCES OR MOTORS WITH A RATING OF 1 HP OR 6 AMPS SHALL BE ON A SEPARATE CIRCUIT. 13. FOR HVAC EQUIPMENT, A SEPARATE 15A OR 20A CIRCUIT WITH AN ACCESSIBLE RECEPTACLE AT THE EQUIPMENT SHALL BE PROVIDED WITHIN 25 FT OF THE EQUIPMENT (CEC 210.63). IF LOCATED IN AN UNDER FLOOR AREA, THE RECETACLE SHALL BE GFCI (CEC 210.8 (4)). D. LIGHTING (CEC 210.70) 1. SWITCHED LIGHTING SHALL BE INSTALLED IN: - ALL HABITABLE ROOMS, BATHROOMS, HALLWAYS, AND STAIRWAYS AT EACH LEVEL, - AT ALL OUTDOOR ENTRANCES AND EXITS, - IN ALL ATTICS, UNDER FLOOR AREAS, UTILITY ROOMS AND BASEMENTS USED FOR STORAGE, - NEAR HVAC EQUIPMENT IN ATTIC, UNDER FLOOR AREAS, ROOMS OR BASEMENTS, WITH A SWITCH AT THE ACCESS POINT. 2. LIGHTING INSTALLED IN A CLOSET SHALL BE A SURFACE MOUNTED OR RECESSED FLUORESCENT FIXTURE OR A SURFACE MOUNTED INCANDESCENT FIXTURE WITH COMPLETELY ENCLOSED LAMPS OR RECESSED INCANDESCENT FIXTURE WITH COMPLETELY ENCLOSED LAMPS. SURFACE INCANDESCENT LIGHTING SHALL BE INSTALLED A MINIMUM OF 12 IN. FROM THE NEAREST POINT OF A STORAGE SPACE. SURFACE FLUORESCENT LIGHTING AND RECESSED LIGHTING SHALL BE INSTALLED A MINIMUM OF 6 IN. FROM THE NEAREST POINT OF A STORAGE SPACE. (CEC 410.16.(C)). E. FANS IN BATHROOMS CONTAINING TUBS OR SHOWERS, A FAN CAPABLE OF EXHAUSTING 50 CFM SHALL BE INSTALLED (ENERGY STANDARDS 150 (O)). F. SMOKE ALARMS IN NEW CONSTRUCTION, SMOKE ALARMS SHALL RECIEVE THEIR PRIMARY POWER FROM THE BUILDING WIRING. THE WIRING SHALL BE PERMANENT AND INSTALLED WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION (CBC [F] 907.2.11.6). STORM WATER MANAGEMENT: 1. ERODED SEDIMENTS AND OTHER POLLUTANTS MUST BE RETAINED ON SITE AND MAY NOT BE TRANSPORTED FROM THE SITE VIA SHEETFLOW, SWALES, AREA DRAINS, NATURAL DRAINAGE COURSES OR WINDS. 2. STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND OR WATER. 3. FUELS, OILS, SOLVENTS AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE SYSTEM. 4. NON-STORMWATER RUNOFF FROM EQUIPMENT AND VEHICLE WASHING AND ANY OTHER ACTIVITY SHALL BE CONTAINED AT THE PROJECT SITE. 5. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES ON SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE. 6. TRASH AND CONSTRUCTOIN RELATED SOLID WASTES MUST BE DEPOSITED INTO A CONVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPEARSAL BY WIND. 7. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY. 8. ACCIDENTAL DESPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS. 9. ANY SLOPES WITH DISTURBED SOILS OR DENUDED OF VEGETATION MUST BE STABILIZED SO AS TO INHIBIT EROSION BY WIND AND WATER. 10. SCHEDULE CONSTRUCTION ACTIVITY TO REDUCE AREA AND DURATION OF SOIL EXPOSED TO EROSION BY WIND, RAIN, RUNOFF AND VEHICLE TRACKING. 1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2022 EDITION OF THE CBC, CRC, CMC, CPC, AND CEC AS ADOPTED AND AMENDED BY THE STATE OF CALIFORNIA IN TITLE 24 CCR AND THIS JURISDICTION. 2. SEPARATE PERMITS MAY BE REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, SHORING, GRADING, AND DEMOLITION. 3. ALL PROPERTY LINES, EASEMENTS, AND EXISTING BUILDINGS HAVE BEEN INDICATED ON THIS SITE PLAN. 4. A SECURITY FENCE SHALL BE PROVIDED AROUND THE CONSTRUCTION AREA THAT SHALL BE INSTALLED PRIOR TO EXCAVATION AND/OR FOUNDATION TRENCHING. (BMC 9-1-1-3302.3) 5. WATER SHALL BE PROVIDED ON THE SITE AND USED TO CONTROL DUST. 6. TEMPORARY TOILET FACILITIES SHALL BE PROVIDED ON SITE. (BMC 9-1-1-3305) 7. THE FINISH GRADE SHALL SLOPE A MIN. OF 5%, OR 6", TO A POINT 10 FEET FROM BUILDING FOUNDATION, OR TO AN APPROVED ALTERNATE METHOD OF DIVERTING WATER AWAY FROM THE FOUNDATION. SWALES SHALL SLOPE A MINIMUM OF 2%. (CRC R401.3) 8. THE TOP OF THE EXTERIOR FOUNDATION SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER A MINIMUM OF 12" PLUS 2%. (CRC R403.1.7.3) GENERAL NOTES: FOUNDATION NOTES: SECURITY REQUIREMENTS: 1. ALL ENTRY DOORS TO DWELLING UNITS OR GUEST ROOMS SHALL BE ARRANGED SO THAT THE OCCUPANT HAS A VIEW OF THE AREA IMMEDIATELY OUTSIDE THE DOOR WITHOUT OPENING THE DOOR. SUCH VIEW MAY BE PROVIDED BY A DOOR VIEWER, THROUGH WINDOWS LOCATED IN THE VICINITY OF THE DOOR OR THROUGH VIEW PORTS IN THE DOOR OR ADJOINING WALL. (6706) 2. SCREENS, BARRICADES, OR FENCES MADE OF A MATERIAL WHICH WOULD PRECLUDE HUMAN CLIMBING SHALL BE PROVIDED AT EVERY PORTION OF EVERY ROOF, BALCONY, OR SIMILAR SURFACE WHICH IS WITHIN 8 FT. OF THE UTILITY POLE OR ACCESS STRUCTURES. (6707) 3. WOOD FLUSH-TYPE DOORS SHALL BE 1 3/8" THICK MINIMUM WITH SOLID CORE CONSTRUCTION. (6709.1) DOOR STOPS OF IN-SWINGING DOORS SHALL BE OF ONE-PIECE CONSTRUCTION WITH THE JAMB, OR JOINED BY RABBET TO THE JAMB. (6709.4) 4. EVERY DOOR IN A SECURITY OPENING FOR AN APARTMENT HOUSE SHALL BE PROVIDED WITH INCANDESCENT LIGHT BULB (60 WATT MIN) AT A MAXIMUM HEIGHT OF 8 FEET ON THE EXTERIOR SIDE OF THE UNIT. (6708) 5. ALL PIN-TYPE DOOR HINGES ACCESSIBLE FROM OUTSIDE SHALL HAVE NON-REMOVABLE HINGE PINS. HINGES SHALL HAVE MIN. 1/4" DIA. STEEL JAMB STUD WITH 1/4" MIN. PROTECTION. THE STRIKE PLATE FOR LATCHES AND HOLDING DEVICE FOR PROJECTING DEAD BOLTS IN WOOD CONSTRUCTION SHALL BE SECURED TO THE JAMB AND THE WALL FRAMING WITH SCREWS NO LESS THAN 2-1/2" LONG. (6709.5, 6709.7) 6. PROVIDE DEAD BOLTS WITH HARDENED INSERTS; DEADLOCKING LATCH WITH KEY-OPERATED LOCKS ON EXTERIOR. DOORS MUST BE OPERABLE FROM THE INSIDE WITHOUT A KEY, SPECIAL KNOWLEDGE, OR SPECIAL EFFORT (LATCH NOT REQUIRED IN B, F, M AND S OCCUPANCIES). (6709.2) 7. STRAIGHT DEAD BOLTS SHALL HAVE A MIN. THROW OF 1" AND AN EMBEDMENT OF NOT LESS THAN 5/8", AND A HOOK-SHAPED OR AN EXPANDING-LUG DEADBOLT SHALL HAVE A MINIMUM THROW OF 3/4". (6709.2) 8. WOOD PANEL TYPE DOORS MUST HAVE PANELS AT LEAST 9/16 INCH THICK WITH SHAPED PORTIONS OF THE PANELS NOT LESS THAN 1/4 INCH THICK, AND INDIVIDUAL PANELS MUST BE NO MORE THAN 300 SQ. IN. IN AREA. MULLIONS SHALL BE CONSIDERED A PART OF ADJACENT PANELS EXCEPT MULLIONS NOT OVER 18 INCHES LONG MAY HAVE AN OVERALL WIDTH OF NOT LESS THAN 2 INCHES. STILES AND RAILS SHALL BE OF SOLID LUMBER IN THICKNESS WITH OVERALL DIMENSIONS OF NOT LESS THAN 1 3/8 INCHES AND 3 INCHES IN WIDTH. (6709.1 ITEM 2) 9. SLIDING GLASS DOORS SHALL BE PROVIDED WITH A DEVICE IN THE UPPER CHANNEL OF THE MOVING PANEL TO PROHIBIT RAISING AND REMOVAL OF THE MOVING PANEL FROM THE TRACK WHILE IN THE CLOSED POSITION. (6710) 10. SLIDING GLASS DOORS SHALL BE EQUIPPED WITH LOCKING DEVICES AND SHALL BE SO CONSTRUCTED AND INSTALLED THAT THEY REMAIN INTACT AND ENGAGED WHEN SUBJECTED TO THE TESTS SPECIFIED IN SEC. 6717.1 11. METAL OR WOODEN OVERHEAD AND SLIDING DOORS SHALL BE SECURED WITH A CYLINDER LOCK, PADLOCK WITH A MIN. 9/32" DIAMETER HARDENED STEEL SHACKLE BOLTED, HARDENED STEEL HASPS, METAL SLIDE BOARD, BOLT OR EQUIVALENT DEVICE UNLESS SECURED ELECTRICALLY OPERATED. (6711) 12. PROVIDE METAL GUIDES AT TOP AND BOTTOM OF METAL ACCORDION GRATE OR GRILLE-TYPE DOORS AND CYLINDER LOCKS OR PADLOCKS. CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDER LOCKS WHENEVER THE CYLINDER PROJECTS BEYOND THE FACE OF THE DOOR OR IS OTHERWISE ACCESSIBLE TO GRIPPING TOOLS. (6712) 13. IN GROUP B, F, M, AND S OCCUPANCIES, PANES OF GLAZING WITH AT LEAST ONE DIMENSION GREATER THAN 6 IN. BUT LESS THAN 48 IN, SHALL BE CONSTRUCTED OF TEMPERED OR APPROVED BURGLARY-RESISTANT MATERIAL OR PROTECTED WITH METAL BARS OR GRILLES. (6714) 14. GLAZED OPENINGS WITHIN 40" OF THE DOOR LOCK WHEN THE DOOR IS IN THE CLOSED AND LOCKED POSITION, SHALL BE FULLY TEMPERED GLASS OR APPROVED BURGLARY-RESISTANT MATERIAL, OR SHALL BE PROTECTED BY METAL BARS, SCREENS OR GRILLES HAVING A MAXIMUM OPENING OF 2". THE PROVISIONS OF THIS SECTION SHALL NOT APPLY TO VIEW PORTS OR WINDOWS WHICH DO NOT EXCEED 2" IN THEIR GREATEST DIMENSIONS. (6713) 15. LOUVERED WINDOWS SHALL BE PROTECTED BY METAL BARS OR GRILLES WITH OPENINGS THAT HAVE AT LEAST ONE DIMENSION OF 6" OR LESS, WHICH ARE CONSTRUCTED TO PRECLUDE HUMAN ENTRY. (6715.3) 16. OTHER OPENABLE WINDOWS SHALL BE PROVIDED WITH SUBSTANTIAL LOCKING DEVICES. IN GROUP B, F, M AND S OCCUPANCIES, SUCH DEVICES SHALL BE GLIDE BARS, BOLTS, CROSS-BARS, AND/OR PADLOCKS WITH MINIMUM 9/32" HARDENED STEEL SHACKLES AND BOLTED, HARDENED STEEL HASPS. (6715.2) 17. SLIDING WINDOWS SHALL BE PROVIDED WITH LOCKING DEVICE IN THE UPPER CHANNEL OF THE MOVING PANEL TO PROHIBIT RAISING AND REMOVAL OF THE MOVING PANEL IN THE CLOSED OR PARTIALLY OPEN POSITION. (6715.1) 18. SLIDING WINDOWS SHALL BE EQUIPPED WITH LOCKING DEVICES AND SHALL BE SO CONSTRUCTED AND INSTALLED THAT THEY REMAIN INTACT AND ENGAGED WHEN SUBJECTED TO THE TESTS SPECIFIED IN SEC. 6717.2. 19. ANY RELEASE FOR METAL BARS, GRILLES, GRATES OR SIMILAR DEVICES CONSTRUCTED TO PRECLUDE HUMAN ENTRY THAT ARE INSTALLED SHALL BE LOCATED ON THE INSIDE OF THE ADJACENT ROOM AND AT LEAST 24 INCHES FROM THE CLOSEST OPENING THROUGH SUCH METAL BARS, GRILLES, GRATES OR SIMILAR DEVICES THAT EXCEEDS TWO INCHES IN ANY DIMENSION. (6715.4) 20 ALL OTHER OPENINGS MUST BE PROTECTED BY METAL BARS OR GRILLES WITH OPENINGS OF NOT LESS THAN 6 INCHES IN ONE DIMENSION. (6716) 1. CONCRETE STRENGTH FOR FOUNDATION SHALL BE 2,500 PSI MIN. (CRC R404.1.3.3.1. TABLE R402.2) 2. MINIMUM FOOTING REINFORCEMENT SHALL BE ONE #4 BAR TOP AND BOTTOM (CRC R403.1.3). 3. MINIMUM ANCHOR BOLT SIZE AND SPACING SHALL BE 5.8" DIA. AB @ 72" OC., WITH 7" EMBEDMENT, AND 3" X 3" X 1/4" PLATE WASHERS. ANCHOR BOLTS SHALL BE LOCATED A MAXIMUM OF 12" AND 4 1/2" MINIMUM FROM THE END OF THE PLATE (CRC R403.1.6, R602.11.1). WATER CONSERVATION: ELECTRICAL NOTES: A. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. B. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWNSTREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE 170,158) (SEPARATE PLUMBING PERMIT IS REQUIRED). C. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR TO AN APPROVED SEWAGE DISPOSAL SYSTEM (R306.3). D. KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND CONNECTED TO AN APPROVED WATER SUPPLY (R306.4). E. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR (R307.2). F. PROVIDE ULTRA-FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. G. UNIT SKYLIGHTS SHALL BE LABELED BY A HATHORNEWOOD CITY APPROVED LABELING AGENCY. SUCH LABEL SHALL STATE THE APPROVED LABELING AGENCY NAME, PRODUCT DESIGNATION AND PERFORMANCE GRADE RATING. (RESEARCH REPORT NOT REQUIRED). (R308.6.9) H. WATER HEATER MUST BE STRAPPED TO WALL. (SEC. 507.3, LAPC) I. FOR EXISTING POOL ON SITE, PROVIDE AN ALARM FOR DOORS TO THE DWELLING THAT FORM A PART OF THE POOL ENCLOSURE. THE ALARM SHALL SOUND CONTINUOUSLY FOR A MIN. OF 30 SECONDS WHEN THE DOOR IS OPENED. IT SHALL AUTOMATICALLY RESET AND BE EQUIPPED WITH A MANUAL MEANS TO DEACTIVATE (FOR 15 SECS. MAX.) FOR A SINGLE OPENING. THE DEACTIVATION SWITCH SHALL BE AT LEAST 54" ABOVE THE FLOOR. (6109 OF LABC) J. FOR EXISTING POOL ON SITE, PROVIDE ANTI– ENTRAPMENT COVER MEETING THE CURRENT ASTM OR ASME FOR THE SUCTION OUTLETS OF THE SWIMMING POOL, TODDLER POOL AND SPA FOR SINGLE FAMILY DWELLINGS PER ASSEMBLY BILL (AB) NO. 2977. (3162B) K. AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH UL 325. (R309.4) L. SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDED FOR HUMAN OCCUPANCY, UPON THE OWNER’S APPLICATION FOR A PERMIT FOR ALTERATIONS, REPAIRS, OR ADDITIONS, EXCEEDING ONE THOUSAND DOLLARS ($1,000). (R314.6.2) M. WHERE A PERMIT IS REQUIRED FOR ALTERATIONS, REPAIRS OR ADDITIONS EXCEEDING ONE THOUSAND DOLLARS ($1,000), EXISTING DWELLINGS OR SLEEPING UNITS THAT HAVE ATTACHED GARAGES OR FUEL-BURNING APPLIANCES SHALL BE PROVIDED WITH A CARBON MONOXIDE ALARM IN ACCORDANCE WITH SECTION R315.2. CARBON MONOXIDE ALARMS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS OBTAINED. (R315.2.2) N. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN AVERAGE ILLUMINATION OF 6 FOOT-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30 INCHES ABOVE THE FLOOR LEVEL. (R303.1) O. A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE P. PROVIDE (70) (72) INCH HIGH NON ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER RESISTANT MATERIALS FOR SHOWER ENCOSURE. (1209.2.2, 2406.4.5, R307.2, R308.4) 1. IN COMBUSTIBLE CONSTRUCTION, FIRE BLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. (R302.11) 2. IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET. DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. (R302.12) 1. AN APPROVED SMOKE ALARM SHALL BE INSTALLED IN EACH SLEEPING ROOM & HALLWAY OR AREA GIVING ACCESS TO A SLEEPING ROOM, AND ON EACH STORY AND BASEMENT FOR DWELLINGS WITH MORE THAN ONE STORY. SMOKE ALARMS SHALL BE INTERCONNECTED SO THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS WITHIN THE INDIVIDUAL DWELLING UNIT. IN NEW CONSTRUCTION SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER SOURCE FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH BATTERY BACK-UP AND LOW BATTERY SIGNAL. (R314) 2. AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. CARBON MONOXIDE ALARM SHALL BE PROVIDED OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S) AND ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. (R315) FIRE-RESISTANCE RATED CONSTRUCTION: FIRE PROTECTION: 1. PROVIDE 15" MINIMUM BETWEEN THE CENTER OF WATER CLOSET TO ANY SIDE WALL. (CALIF. PLUMB. CODE 407.6) 2. PROVIDE 24" CLEAR SPACE IN FRONT OF ANY WATER CLOSET. (CALIF. PLUMB. CODE 407.6) 3. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED NATURAL VENTILATION OR WITH MECHANICAL VENTILATION CAPABLE OF 50 CFM EXHAUSTED DIRECTLY TO THE OUTSIDE (R303.3) 4. HEATER SHALL BE CAPABLE OF MAINTAINING A MINIMUM ROOM TEMPERATURE OF 68°F AT A POINT 3 FEET ABOVE THE FLOOR AND 2 FEET FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE DESIGN TEMPERATURE. (R303.9) 1. PROVIDE A CLASS A, B OR C FIRE-RETARDANT ROOF COVERING PER SECTION 1505. 3. GLAZING IN THE FOLLOWING LOCATIONS SHALL BE SAFETY GLAZING CONFORMING TO THE HUMAN IMPACT LOADS OF SECTION 2406.1 (SEE EXCEPTIONS): A. FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BI-FOLD DOOR ASSEMBLIES. B. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE. C. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 1) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET. 2) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. 3) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. 4) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE GLAZING. G. GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 36 INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE OF STAIRWAYS, LANDINGS BETWEEN FLIGHTS OF STAIRS AND RAMPS. 5. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS WITH A MINIMUM FALL OF 6 INCHES WITHIN THE FIRST 10 FEET (1804.4). 6. DAMPPROOFING, WHERE REQUIRED, SHALL BE INSTALLED WITH MATERIALS AND AS REQUIRED IN SECTION R406.1. 8. BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. (502.1) 9. PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE PROVIDED IN THE LOCATIONS SPECIFIED PER SECTION R317.1 BY THE USE OF NATURALLY DURABLE WOOD OR WOOD THAT IS PRESERVATIVE-TREATED IN ACCORDANCE WITH AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE. PRESERVATIVES SHALL BE LISTED IN SECTION 4 OF AWPA U1. 10. PROVIDE ANTI-GRAFFITI FINISH WITHIN THE FIRST 9 FEET, MEASURED FROM GRADE, AT EXTERIOR WALLS AND DOORS. EXCEPTION: MAINTENANCE OF BUILDING AFFIDAVIT IS RECORDED BY THE OWNER TO COVENANT AND AGREE WITH THE CITY OF HATHORNEWOOD TO REMOVE ANY GRAFFITI WITHIN 7-DAYS OF THE GRAFFITI BEING APPLIED. (6306) INTERIOR ENVIRONMENT: BUILDING ENVELOPE: GENERAL NOTES: No. Description Date 1806 W 15th St & Unit #25/1/2025 DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:49 PM G003 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 CAL GREEN 1 No. Description Date 1806 W 15th St & Unit #25/1/2025 DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:51 PM G004 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 CAL GREEN 2 No. Description Date 1806 W 15th St & Unit #25/1/2025 DATE: CONTRACTOR TO VERIFY ALL DIMENSIONS, CONDITIONS, ETC., PERTAINING TO THE WORK AT THE SITE BEFORE PROCEEDING WITH THE WORK AS INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF ADU RESOURCE CENTER NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF ADU RESOURCE CENTER. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DRAWN BY: 600 N. BRAND BLVD. #560 GLENDALE CA. 91203 (818) 450-8422 ARCHITECTURE@ADURESOURCECENTER.COM 11/8/2024 3:04:52 PM G005 EX I S T I N G S F R CO N V E R S I O N ( 1 4 6 . 5 6 S F ) + A D D I T I O N ( 3 3 5 . 0 2 S F ) TO N E W O N E S T O R Y AT T A C H E D A D U ( 4 9 1 . 0 8 SF ) 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A AN A , C A 9 2 7 0 6 AGING-IN-PLACE No. Description Date 1806 W 15th St & Unit #25/1/2025 T-1 Scale Project number Date Drawn by Checked by nalserengineering@gmail.com 818-913-7525 GARAGE TO ADU TITLE -24 TI T L E - 2 4 P E R F O R M A N C E AD D R E S S : 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A A N A , C A 9 2 7 0 6 OW N E R : S.N S.N 11/01/2023 1806 W 15th St & Unit #25/1/2025 T-2 Scale Project number Date Drawn by Checked by nalserengineering@gmail.com 818-913-7525 GARAGE TO ADU TITLE -24 TI T L E - 2 4 P E R F O R M A N C E AD D R E S S : 18 0 6 W 1 5 T H S T , U N I T 2 , S A N T A A N A , C A 9 2 7 0 6 OW N E R : S.N S.N 11/01/2023 1806 W 15th St & Unit #25/1/2025 SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa-ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Thai Viet Phan COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org INTERIM CITY MANAGER Tom Hatch CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall March 22, 2024 Also sent via email to: danamarielusiani@gmail.com Dana Lusiani 1806 W Fifteenth Street Santa Ana, CA 92706 Subject: Address Assignment for an Attached Accessory Dwelling Unit located at 1806 West Fifteenth Street (APN: 405-091-24) in Santa Ana, CA Dear Dana, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a 502-square-foot attached ADU located at 1806 West Fifteenth Street (APN: 405-091-24). Notice is hereby given that the following assigned address shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address to be Activated/Posted 1806 West Fifteenth Street To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 664-2753 or by email at PRaj@santa-ana.org. Sincerely, Punkaj Raj Planning Technician Exhibit A – Address Plan 1806 W 15th St & Unit #25/1/2025 Address Letter for 1806 West Fifteenth Street Page 2 of 2 c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Mishele Richards, Orange County Fire Authority, GEO Files Coordinator Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Alvaro Nunez, PBA Assistant Director and Code Enforcement Manager 1806 W 15th St & Unit #25/1/2025 (N) ADU1806 W 15THSTREET, UNIT 2 (E) PRIMARY DWELLING1806 W 15TH STREET EXHIBIT A: ADRESS PLAN 1806 W 15th St & Unit #25/1/2025 STRUCTURAL CALCULATIONS PROJECT: 1806 W 15th St., Santa Ana, CA 92706 JOB #23-544 12-05-24 BY: Shant Shahbaz 1806 W 15th St & Unit #25/1/2025 Roof: D.L (psf)20 L.L (psf)20 Floor:Wall: D.L (psf)16 L.L (psf)15 10 L.L (psf)40 15 wL = (T.A.i * L.L.i) L.L (psf) D.L (psf)16 D.L (psf) L.L (psf)60 L= Length D.L. =Dead Load T.A = Tributary Area L.L = Live Load wD = (T.A.i * D.L.i) ←wD, wL RR (1) L (ft)11'Cantilever 1' T.A. (ft)1.33 wD (lb/ft)27 wL (lb/ft)27 2 x 12 @ 16" O.C. (No.2)↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 11' ←D, wL RBM (1) L (ft)17.5'Cantilever 1' T.A.roof (ft)10 wD (lb/ft)200 wL (lb/ft)200 3½x 14 (Prllm)↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 17.5' ←D, wL HDR(1) L (ft)6' T.A.roof (ft)6 wD 120 wL (lb/ft)120 4 x 6 (No. 2) ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 6' ←D, wL HDR(2) L (ft)3' T.A.roof (ft)6 wD 120 wL (lb/ft)120 4 x 6 (No. 2) ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 3' SPS ENGINEERING 818 747 7269 | shant.sps@gmail.com 1806 W 15th St & Unit #25/1/2025 Roof Framing: ←wD, wL HDR(3) L (ft)5' T.A.roof (ft)6 wD (lb/ft)120 wL (lb/ft)120 ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 5' 4 x 6 (No. 2) ←D, wL HDR(4) L (ft)3' T.A.roof (ft)3 wD (lb/ft)60 wL (lb/ft)60 4 x 6 (No. 2) ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 3' ←D, wL HDR(5) L (ft)3' T.A.roof (ft)5.5 wD (lb/ft)110 wL (lb/ft)110 ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 3' ←D, wL HDR(6) L (ft)5' T.A.roof (ft)3 wD (lb/ft)60 wL (lb/ft)60 ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 5' SPS ENGINEERING 818 747 7269 | shant.sps@gmail.com 1806 W 15th St & Unit #25/1/2025 Foundation Framing: ←wD, wL FJ (1) L (ft)18' T.A. (ft)1.33 wD (lb/ft)21 wL (lb/ft)53 2 x 6 @ 16" O.C. (No.2)↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 18' ←D, wL BM(2) L (ft)5' T.A. (ft)9 wD (lb/ft)144 wL (lb/ft)360 4 x 6 (No. 2) ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 5' SPS ENGINEERING 818 747 7269 | shant.sps@gmail.com 1806 W 15th St & Unit #25/1/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RR1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: 15TH ST.ec6 CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.0270, L = 0.0270 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.242: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 4.972 ft 19.95 psi= = 1,035.00 psi 2x12Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 180.00 psi== Section used for this span 2x12 Maximum Shear Stress Ratio 0.111 : 1 9.106 ft= = 250.90 psi Maximum Deflection 3672 >=360 2855 Ratio =1836 >=240 Max Downward Transient Deflection 0.021 in 5711Ratio =>=360 Max Upward Transient Deflection -0.007 in Ratio = Max Downward Total Deflection 0.042 in Ratio =>=240 Max Upward Total Deflection -0.013 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only Span: 2 : L Only Span: 1 : +D+L Span: 2 : +D+L .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 10.0 ft 1 0.135 0.062 0.90 1.000 1.151.00 1.00 0.33 125.5 931.5 0.11 162.01.00 10.01.00 1.00Length = 1.0 ft 2 0.005 0.062 0.90 1.000 1.151.00 1.00 0.01 5.1 931.5 0.00 162.01.00 10.01.00 1.00+D+L 1.000 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 10.0 ft 1 0.242 0.111 1.00 1.000 1.151.00 1.00 0.66 250.9 1,035.0 0.22 180.01.00 19.91.00 1.00Length = 1.0 ft 2 0.010 0.111 1.00 1.000 1.151.00 1.00 0.03 10.2 1,035.0 0.00 180.01.00 19.91.00 1.00+D+0.750L 1.000 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 10.0 ft 1 0.170 0.078 1.25 1.000 1.151.00 1.00 0.58 219.5 1,293.8 0.20 225.01.00 17.51.00 1.00Length = 1.0 ft 2 0.007 0.078 1.25 1.000 1.151.00 1.00 0.02 9.0 1,293.8 0.00 225.01.00 17.51.00 1806 W 15th St & Unit #25/1/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RR1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: 15TH ST.ec6 Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+0.60D 1.000 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 10.0 ft 1 0.045 0.021 1.60 1.000 1.151.00 1.00 0.20 75.3 1,656.0 0.07 288.01.00 6.01.00 1.00Length = 1.0 ft 2 0.002 0.021 1.60 1.000 1.151.00 1.00 0.01 3.1 1,656.0 0.00 288.01.00 6.01.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L 1 0.0420 5.028 0.0000 0.000 +D+L20.0000 5.028 -0.0131 1.000 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.267 0.327 Max Upward from Load Combinations 0.267 0.327 Max Upward from Load Cases 0.134 0.163 D Only 0.134 0.163 +D+L 0.267 0.327 +D+0.750L 0.234 0.286 +0.60D 0.080 0.098 L Only 0.134 0.163 1806 W 15th St & Unit #25/1/2025 Wood Beam LIC# : KW-06019339, Build:20.24.02.28 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RBM1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: 15TH ST.ec6 CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.2E 2,900.0 2,900.0 2,900.0 750.0 2,200.0 1,118.19 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.20, L = 0.20 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.497: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 8.204 ft 87.85 psi= = 2,850.80 psi 3.5x14.0Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 290.00 psi== Section used for this span 3.5x14.0 Maximum Shear Stress Ratio 0.303 : 1 15.394 ft= = 1,418.24 psi Maximum Deflection 662 >=360 522 Ratio =330 >=240 Max Downward Transient Deflection 0.189 in 1045Ratio =>=360 Max Upward Transient Deflection -0.036 in Ratio = Max Downward Total Deflection 0.379 in Ratio =>=240 Max Upward Total Deflection -0.072 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only Span: 2 : L Only Span: 1 : +D+L Span: 2 : +D+L .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 16.50 ft 1 0.276 0.168 0.90 0.983 1.001.00 1.00 6.76 709.1 2,565.7 1.43 261.01.00 43.91.00 1.00Length = 1.0 ft 2 0.004 0.168 0.90 0.983 1.001.00 1.00 0.10 10.5 2,565.7 0.20 261.01.00 43.91.00 1.00+D+L 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.50 ft 1 0.497 0.303 1.00 0.983 1.001.00 1.00 13.51 1,418.2 2,850.8 2.87 290.01.00 87.81.00 1.00Length = 1.0 ft 2 0.007 0.303 1.00 0.983 1.001.00 1.00 0.20 21.0 2,850.8 0.40 290.01.00 87.81.00 1.00+D+0.750L 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.50 ft 1 0.348 0.212 1.25 0.983 1.001.00 1.00 11.82 1,241.0 3,563.5 2.51 362.51.00 76.91.00 1.00Length = 1.0 ft 2 0.005 0.212 1.25 0.983 1.001.00 1.00 0.18 18.4 3,563.5 0.35 362.51.00 76.91.00 1806 W 15th St & Unit #25/1/2025 Wood Beam LIC# : KW-06019339, Build:20.24.02.28 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RBM1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: 15TH ST.ec6 Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+0.60D 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.50 ft 1 0.093 0.057 1.60 0.983 1.001.00 1.00 4.05 425.5 4,561.3 0.86 464.01.00 26.41.00 1.00Length = 1.0 ft 2 0.001 0.057 1.60 0.983 1.001.00 1.00 0.06 6.3 4,561.3 0.12 464.01.00 26.41.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L 1 0.3789 8.296 0.0000 0.000 +D+L20.0000 8.296 -0.0723 1.000 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 3.288 3.712 Max Upward from Load Combinations 3.288 3.712 Max Upward from Load Cases 1.644 1.856 D Only 1.644 1.856 +D+L 3.288 3.712 +D+0.750L 2.877 3.248 +0.60D 0.986 1.114 L Only 1.644 1.856 1806 W 15th St & Unit #25/1/2025 Wood Beam LIC# : KW-06019339, Build:20.24.10.30 SPS Engineering (c) ENERCALC, LLC 1982-2024 DESCRIPTION:HDR1-6 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: 15TH ST.ec6 CODE REFERENCES Calculations per NDS 2018, IBC 2021, SDPWS 2021 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.120, L = 0.120 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.546: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 3.000 ft 47.91 psi= = 1,345.50 psi 4x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 180.00 psi== Section used for this span 4x6 Maximum Shear Stress Ratio 0.266 : 1 0.000 ft= = 734.45 psi Maximum Deflection 1588 <360 794 Ratio =0 <240 Max Downward Transient Deflection 0.045 in 0 Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.091 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 6.0 ft 1 0.303 0.148 0.90 1.300 1.151.00 1.00 0.54 367.2 1,211.0 0.31 162.01.00 24.01.00 1.00+D+L 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.546 0.266 1.00 1.300 1.151.00 1.00 1.08 734.5 1,345.5 0.61 180.01.00 47.91.00 1.00+D+0.750L 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.382 0.186 1.25 1.300 1.151.00 1.00 0.95 642.6 1,681.9 0.54 225.01.00 41.91.00 1.00+0.60D 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.102 0.050 1.60 1.300 1.151.00 1.00 0.32 220.3 2,152.8 0.18 288.01.00 14.41.00 . 1806 W 15th St & Unit #25/1/2025 Wood Beam LIC# : KW-06019339, Build:20.24.10.30 SPS Engineering (c) ENERCALC, LLC 1982-2024 DESCRIPTION:HDR1-6 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: 15TH ST.ec6 LocationLoad CombinationMax.LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+L1 0.0907 3.022 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.720 0.720 Max Upward from Load Combinations 0.720 0.720 Max Upward from Load Cases 0.360 0.360 D Only 0.360 0.360 +D+L 0.720 0.720 +D+0.750L 0.630 0.630 +0.60D 0.216 0.216 L Only 0.360 0.360 1806 W 15th St & Unit #25/1/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:FJ1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: 15TH ST.ec6 CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.0210, L = 0.0530 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.884: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 4.500 ft 54.80 psi= = 1,345.50 psi 2x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 180.00 psi== Section used for this span 2x6 Maximum Shear Stress Ratio 0.304 : 1 8.573 ft= = 1,188.89 psi Maximum Deflection 0 <360 327 Ratio =0 <240 Max Downward Transient Deflection 0.237 in 456Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.330 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 9.0 ft 1 0.279 0.096 0.90 1.300 1.151.00 1.00 0.21 337.4 1,211.0 0.09 162.01.00 15.61.00 1.00+D+L 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.884 0.304 1.00 1.300 1.151.00 1.00 0.75 1,188.9 1,345.5 0.30 180.01.00 54.81.00 1.00+D+0.750L 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.580 0.200 1.25 1.300 1.151.00 1.00 0.62 976.0 1,681.9 0.25 225.01.00 45.01.00 1.00+0.60D 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.094 0.032 1.60 1.300 1.151.00 1.00 0.13 202.4 2,152.8 0.05 288.01.00 9.31.00 . 1806 W 15th St & Unit #25/1/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:FJ1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: 15TH ST.ec6 Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L 1 0.3302 4.533 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.333 0.333 Max Upward from Load Combinations 0.333 0.333 Max Upward from Load Cases 0.239 0.239 D Only 0.095 0.095 +D+L 0.333 0.333 +D+0.750L 0.273 0.273 +0.60D 0.057 0.057 L Only 0.239 0.239 1806 W 15th St & Unit #25/1/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:BM2 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: 15TH ST.ec6 CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.1440, L = 0.360 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.796: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 2.500 ft 80.27 psi= = 1,345.50 psi 4x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 180.00 psi== Section used for this span 4x6 Maximum Shear Stress Ratio 0.446 : 1 0.000 ft= = 1,071.07 psi Maximum Deflection 0 <360 653 Ratio =0 <240 Max Downward Transient Deflection 0.066 in 914Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.092 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 5.0 ft 1 0.253 0.142 0.90 1.300 1.151.00 1.00 0.45 306.0 1,211.0 0.29 162.01.00 22.91.00 1.00+D+L 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 5.0 ft 1 0.796 0.446 1.00 1.300 1.151.00 1.00 1.58 1,071.1 1,345.5 1.03 180.01.00 80.31.00 1.00+D+0.750L 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 5.0 ft 1 0.523 0.293 1.25 1.300 1.151.00 1.00 1.29 879.8 1,681.9 0.85 225.01.00 65.91.00 1.00+0.60D 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 5.0 ft 1 0.085 0.048 1.60 1.300 1.151.00 1.00 0.27 183.6 2,152.8 0.18 288.01.00 13.81.00 . 1806 W 15th St & Unit #25/1/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:BM2 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: 15TH ST.ec6 Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L 1 0.0918 2.518 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.260 1.260 Max Upward from Load Combinations 1.260 1.260 Max Upward from Load Cases 0.900 0.900 D Only 0.360 0.360 +D+L 1.260 1.260 +D+0.750L 1.035 1.035 +0.60D 0.216 0.216 L Only 0.900 0.900 1806 W 15th St & Unit #25/1/2025 ASCE 7-16 Seismic Base Shear LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:Seismic Base Shear Analysis SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: 15TH ST.ec6 Risk Category ASCE 7-16, Page 4, Table 1.5-1 Calculations per ASCE 7-16 "II" : All Buildings and other structures except those listed as Category I, III, and IV Risk Category of Building or Other Structure : Seismic Importance Factor =1 ASCE 7-16, Page 5, Table 1.5-2 Specific Description: EARTHQUAKE Gridded Ss & S1values from ASCE 7-16 ASCE 7-16 11.4.2 Longitude =117.881 deg West Location :Santa Ana, CA 92706 Latitude =33.766 deg North Max. Ground Motions, 5% Damping : S =1.333 Longitude =117.880 deg West S Latitude =33.770 g, 0.2 sec response deg North S 0.47441 g, 1.0 sec response= Conforms to ASCE 7 Section 12.8.1.3: Regular structure with period of 0.5 s or less, SDS limited to max of 0.7*SDS or 1.0 for calculation of Cs. For the closest datapoint grid location . . . Site Class, Site Coeff. and Design Category Classification:ASCE 7-16 Table 20.3-1"D" : Shear Wave Velocity 600 to 1,200 ft/sec =D Site Coefficients Fa & Fv ASCE 7-16 Table 11.4-1 & 11.4-2 (using straight-line interpolation from table values) Fa =1.20 Fv =1.83 Maximum Considered Earthquake Acceleration ASCE 7-16 Eq. 11.4-1S = Fa * Ss 1.600=MS S = Fv * S1 =0.866M1 ASCE 7-16 Eq. 11.4-2 Design Spectral Acceleration ASCE 7-16 Eq. 11.4-3S = S * 2/3 =1.066DSMS =0.577 ASCE 7-16 Eq. 11.4-4S = S * 2/3D1M1 Seismic Design Category ASCE 7-16 Table 11.6-1 & -2=D (By Default per 11.4.3) Resisting System ASCE 7-16 Table 12.2-1 Basic Seismic Force Resisting System . . .Bearing Wall Systems 15.Light-frame (wood) walls sheathed w/wood structural panels rated for shear resistance. NOTE! See ASCE 7-16 for all applicable footnotes. Building height Limits :Response Modification Coefficient " R "=6.50 Category "A & B" Limit:No LimitSystem Overstrength Factor " Wo "=3.00 Category "C" Limit:No LimitDeflection Amplification Factor " Cd "=4.00 Category "D" Limit:Limit = 65 Category "E" Limit:Limit = 65 Category "F" Limit:Limit = 65 Lateral Force Procedure ASCE 7-16 Section 12.8.2 Equivalent Lateral Force Procedure The "Equivalent Lateral Force Procedure" is being used according to the provisions of ASCE 7-16 12.8 Use ASCE 12.8-7Determine Building Period Structure Type for Building Period Calculation :All Other Structural Systems " Ct " value 0.020= " x " value " hn " : Height from base to highest level =15.50 ft " Ta " Approximate fundemental period using Eq. 12.8-7 : 8.000"TL" : Long-period transition period per ASCE 7-16 Maps 22-14 -> 22-17 sec Ta = Ct * (hn ^ x) =0.156 0.75 sec = Building Period " Ta " Calculated from Approximate Method selected=0.156 1806 W 15th St & Unit #25/1/2025 ASCE 7-16 Seismic Base Shear LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:Seismic Base Shear Analysis SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: 15TH ST.ec6 " Cs " Response Coefficient ASCE 7-16 Section 12.8.1.1 S : Short Period Design Spectral Response 1.066 " R " : Response Modification Factor 6.50 " I " : Seismic Importance Factor =1 0.154From Eq. 12.8-2, Preliminary Cs = 0.569From Eq. 12.8-3 & 12.8-4 , Cs need not exceed = From Eq. 12.8-5 & 12.8-6, Cs not be less than =0.044 DS =Cs : Seismic Response Coefficient =0.1538User has selected ASCE 12.8.1.3 : Regular structure, Less than 5 Stories and with T <<= 0.5 sec, SO Ss <= 1.5 for Cs calculation = = Seismic Base Shear ASCE 7-16 Section 12.8.1 W ( see Sum Wi below ) =0.00 kCs =0.1538 from 12.8.1.1 Seismic Base Shear V = Cs * W =0.00 k Vertical Distribution of Seismic Forces ASCE 7-16 Section 12.8.3 " k " : hx exponent based on Ta =1.00 Table of building Weights by Floor Level... Wi : Weight Hi : Height (Wi * Hi^k)Cvx Fx=Cvx * V Sum Story Shear Sum Story MomentLevel # Sum Wi =0.00 k Total Base Shear =0.00 k Base Moment = 0.00 k-ftSum Wi * Hi = 0.0 k-ft Diaphragm Forces : Seismic Design Category "B" to "F"ASCE 7-16 12.10.1.1 Level #Wi Fi Fpx : MaxFpx : CalcdSum Fi Sum Wi Fpx Dsgn. ForceFpx : Min Wpx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Weight at level of diaphragm and other structure elements attached to it. Fi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Design Lateral Force applied at the level. Sum Fi . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Sum of "Lat. Force" of current level plus all levels above 0.20 * S * I * WpxMIN Req'd Force @ Level . . . . . . . . . .DS DSMAX Req'd Force @ Level . . . . . . . . . .0.40 * S * I * Wpx Fpx : Design Force @ Level . . . . . . . . . .Wpx * SUM(x->n) Fi / SUM(x->n) wi, x = Current level, n = Top Level 1806 W 15th St & Unit #25/1/2025 LT Ls = Shortest Wall in any Given Grid Line i i Where: Cs =0.1538 r r 20 7 w (psf) = 27 r r=1.3 5.40 psf Lateral Analysis: (See Enercalc Printout on Previous Page) Shear at Roof (Vr) = V = Shear ENGINEERING 818 747 7269 | shant.sps@gmail.com 1806 W 15th St & Unit #25/1/2025 Line A: LT s T.A.=250 (sq ft)H=12 (ft) V =1350 (lbs)OM =831 (lbs) OM = v * H ν =69 (lb/ft)v = V/L RM =3276 (lbs) RM = 14*Ls Net Uplift =-2445 (lbs) 1 Line B: T.A.=250 (sq ft)H=12 (ft) V =1350 (lbs)OM =1799 (lbs) OM = v * H ν =150 (lb/ft)v = V/L RM =1512 (lbs) RM = 14*Ls Net Uplift =287 (lbs) 1 Line 1: T.A.=250 (sq ft)H=8 (ft) V =1350 (lbs)2nd ν =491 (lb/ft)RM =336 Net Uplift =3590 (lbs) Use Shear Wall Type 3 Use Simpson MST 60 Use Simpson HDU5-SDS2.5 Line 2: T s T.A.=250 (sq ft)H=8 (ft) V =1350 (lbs) ν =400 (lb/ft)RM =392 Net Uplift =2807 (lbs) Use Shear Wall Type 3 Use Simpson MST 48 or MST C48B3 Use Simpson HDU4-SDS2.5 Roof Lateral Analysis: (1st Floor Walls) ENGINEERING 818 747 7269 | shant.sps@gmail.com 1806 W 15th St & Unit #25/1/2025 25$1*( &2817< ),5( $87+25,7< 3ODQ6XEPLWWDO&ULWHULD)RUP 5HTXLUHGIRU6LQJOH)DPLO\RU'XSOH[5HVLGHQFHV 8VH&RPPHUFLDOIRUPIRUORWVZLWKGZHOOLQJXQLWVRUQHZUHVLGHQWLDOWUDFWV  &RPSOHWHWKH3URMHFW,QIRUPDWLRQDQG4XHVWLRQQDLUHEHORZWKHQVLJQDQGGDWHWKH$SSOLFDQW&HUWLILFDWLRQ 3URMHFW,QIRUPDWLRQ …1HZ6LQJOH)DPLO\5HVLGHQFH'XSOH[…$GGLWLRQ5HPRGHO …'8 …2WKH $GGUHVV 8QLW &LW\RU8QLQFRUSRUDWHG&RXQW\$UHD =,3 6FRSHRI:RUN ([LVWLQJ UHD $UHDWR EH$GGHG 7RWDO5HVXOWLQJ UHD 6WRULHV $UHD$GGHGLQ3DVW<HDUV H[FOXGLQJ WKLVSURMHFW  <HV 1R 4XHVWLRQQDLUH2&)$3ODQ7\SHLI³<HV´ ……1HZ²,VWKLVDQHZVLQJOHIDPLO\UHVLGHQFHRUGXSOH[" 35 5HVLGHQWLDO6LWH ZLWK:DWHU$YDLODELOLW\ 35 )LUH6SULQNOHU ……$'8²,VWKLVDQHZ$FFHVVRU\'ZHOOLQJ8QLW $'8 RQWKHVDPHSURSHUW\DVDKRXVHWKDWDOUHDG\KDV ILUHVSULQNOHUVRUDKRXVHWKDWZLOOKDYHILUHVSULQNOHUVDGGHGDVSDUWRIWKLVSURMHFW" 35 )LUH6SULQNOHU ……$GGLWLRQ,VWKLV $ DQDGGLWLRQWRDFXUUHQWO\VSULQNOHUHGEXLOGLQJRU % DQDGGLWLRQUHTXLULQJDILUH VSULQNOHUUHWURILWEDVHGRQD WKUHVKROGVHWE\ORFDORUGLQDQFH" 35 )LUH6SULQNOHU ……'LVWDQFH²,VWKHPRVWUHPRWHSRUWLRQRIWKHDGGLWLRQ$'8RURWKHUGHWDFKHGVWUXFWXUHJUHDWHUWKDQ IHHWIURPWKHILUHDFFHVVURDGZD\" 35 5HVLGHQWLDO6LWH ……7RWDO$UHD²:LOOWKHDGGLWLRQUHVXOWLQDWRWDODUHDRIJUHDWHUWKDQVTXDUHIHHW VI IRUQRQ VSULQNOHUHGEXLOGLQJVRUJUHDWHUWKDQVIIRUVSULQNOHUHGEXLOGLQJVLQFOXGLQJWKHDUHDRIDOO HQFORVHGVSDFHVVXFKDVJDUDJHVVWDLUVDQGGHWDFKHGVWUXFWXUHVVHSDUDWHGE\OHVVWKDQIHHW" 35 5HVLGHQWLDO6LWH ZLWK:DWHU$YDLODELOLW\ ……5HPRGHO,VWKLVDUHPRGHORIDVSULQNOHUHGEXLOGLQJ ZLWKDVFRSHRIZRUNWKDWLQFOXGHVDGGLQJRU UHPRYLQJDQ\LQWHULRUZDOOV"1RWH,I³<HV´WKHQSURMHFWPXVWEHHYDOXDWHGE\D&OLFHQVHG FRQWUDFWRUWRGHWHUPLQHLIDILUHVSULQNOHUPRGLILFDWLRQLVQHHGHG 35 )LUH6SULQNOHU ……'HWDFKHG6WUXFWXUH,VWKLVDQHZGHWDFKHGXWLOLW\RUDFFHVVRU\VWUXFWXUH QRWDQ$'8 VXFKDVD JDUDJHZRUNVKRSJDPHURRPSRROKRXVHEDUQHWFUHTXLULQJILUHVSULQNOHUVEDVHGRQDWKUHVKROG VHWE\ORFDORUGLQDQFH" 35 5HVLGHQWLDO6LWH 35 )LUH6SULQNOHU ……*DWH,VDJDWHEHLQJLQVWDOOHG DFURVVDGULYHZD\RUURDGWKDWLVGHVLJQDWHGDVDILUHGHSDUWPHQW DFFHVVURDGZD\RUDGULYHZD\RUURDGWKDWVHUYHVPRUHWKDQDVLQJOHKRPHGXSOH[" 35 *DWH ……0HWKDQH ²,VSURMHFWORFDWHGLQRUOHVVWKDQ¶IURPD³'LYLVLRQRI2LO*DVDQG*HRWKHUPDO 5HVRXUFHV´ '2**5 ILHOGERXQGDU\RUZHOO DFWLYHRUDEDQGRQHG OHVVWKDQIHHWIURPDQRLOJDV VHHSRUOHVVWKDQIHHWIURPDODQGILOO" 1RWH)RUSURMHFWVLQ<RUED/LQGDWKLVUHTXLUHPHQWRQO\ DSSOLHVWRQHZKRPHVHQFORVHGDFFHVVRU\VWUXFWXUHVDGGLWLRQWRH[LVWLQJVWUXFWXUHJUHDWHUWKDQ VIDQG'8¶V  35 5HVLGHQWLDO6LWH 35 0HWKDQH 7HVW0LWLJDWLRQ3ODQV ……9HJHWDWLRQ²,VWKHSURSHUW\VWUXFWXUH $ RQWKHSHULPHWHURIDFRPPXQLW\FRQWDLQLQJRUDGMDFHQWWR VORSHVRUKLOOVRU % DGMDFHQWWRDQRSHQVSDFHRUZLOGODQGDUHDFRQWDLQLQJQRQLUULJDWHGYHJHWDWLRQ RU & LQD6WDWH5HVSRQVLELOLW\$UHDRU/RFDO5HVSRQVLELOLW\$UHD³)LUH+D]DUG6HYHULW\=RQH´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±$IWHU\RX¶YHYHULILHG DOOTXHVWLRQVZHUHDQVZHUHGDFFXUDWHO\DV³1R´WKHQ\RXPD\DFFHSWWKLVVLJQHGIRUPDVD ZULWWHQUHOHDVHWKDWDQ2&)$UHYLHZLVQRWUHTXLUHG ,IDQ\TXHVWLRQVZHUHDQVZHUHGDV³<HV´WKHQWKHSODQW\SHRQWKHULJKWVLGHPD\EHUHTXLUHG BBB<-BBB,IDOODQVZHUVDUH³1R´DQGWKH%XLOGLQJ'HSDUWPHQWVWLOOUHTXLUHVWKHDSSOLFDQWWRKDYHWKHLUSODQVUHYLHZHGE\2&)$RULIDQ\DQVZHUVDUH ³<HV´DQGWKH%XLOGLQJ'HSDUWPHQWSUHIHUVIRU2&)$WRGHWHUPLQHLIDUHYLHZLVUHTXLUHGSOHDVHLQLWLDOWKLVOLQHDQGSURYLGHDQH[SODQDWLRQRQWKH3ODQ 5HIHUUDO)RUP RQWKHUHYHUVH WREHVXEPLWWHGDORQJZLWKWKHDSSURSULDWHSODQVWR2&)$IRUDGHWHUPLQDWLRQ )RUTXHVWLRQVDQGVXEPLWWDOLQIRUPDWLRQSOHDVHYLVLWRFIDRUJRUFDOO2&)$DW   ^&Z DWLRQ RID WKDW RUPD BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB ✔ 2 SANTA ANA 927061806 W 15TH ST EXISTING SFR CONVERSION ( 146.56 SF) + ADDITION (335.02 SF) TO NEW ONE STORY ATTACHED ADU (491.08 SF) 1755 335.02 2110.9 1 0 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ARCHITECTURE@ADURESOURCECENTER.COM 213-408-3831 ARCHITECTURE@ADURESOURCECENTER.COM 4/19/2024 1806 W 15th St & Unit #25/1/2025 25$1*( &2817< ),5( $87+25,7< 3ODQ5HIHUUDO)RUP 5HTXLUHGIRU2&)$WRUHYLHZSODQVXSRQWKHUHTXHVWRIWKH%XLOGLQJ'HSDUWPHQWZKHQ WKHDQVZHUVRQWKH3ODQ6XEPLWWDO&ULWHULD)RUP RQWKHUHYHUVH DUHDOO³1R´ ŝƚLJKĨĨŝĐŝĂůZĞƋƵĞƐƚŝŶŐZĞǀŝĞǁ͗ ŝƚLJZĞĨĞƌĞŶĐĞη͗ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ ŝƚLJͬŽƵŶƚLJ͗ ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ ĂƚĞ͗ ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ ŽŶƚĂĐƚEĂŵĞ͗ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ ͲDĂŝů͗ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ dŝƚůĞ͗ ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ WŚŽŶĞη͗ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ ΎΎ,ĂǀĞƚŚĞĂƉƉůŝĐĂŶƚĐŽŵƉůĞƚĞĂŶĚƐŝŐŶƚŚĞK&WůĂŶ^ƵďŵŝƚƚĂůƌŝƚĞƌŝĂ&ŽƌŵŽŶƚŚĞƌĞǀĞƌƐĞŽĨƚŚŝƐĨŽƌŵ͘ΎΎ ZĞĂƐŽŶ;ƐͿĨŽƌZĞǀŝĞǁ͗ WůĞĂƐĞĚĞƐĐƌŝďĞǁŚLJK&WůĂŶZĞǀŝĞǁŝƐŽƌŵĂLJďĞƌĞƋƵŝƌĞĚďLJƚŚĞŝƚLJͬŽƵŶƚLJ͗ K&KDDEd^͗ …EŽĨƵƌƚŚĞƌĂĐƚŝŽŶƌĞƋƵŝƌĞĚŽŶƚŚŝƐƐƉĞĐŝĨŝĐƉůĂŶƚLJƉĞ͕ďĂƐĞĚ ŽŶŝŶĨŽƌŵĂƚŝŽŶƉƌŽǀŝĚĞĚŽŶ͗ͺͺͺͺͬͺͺͺͺͺͺͬͺͺͺͺͺͺ͘ …WƌŽũĞĐƚƚŽďĞƚĂŬĞŶŝŶĨŽƌK&ZĞǀŝĞǁ͘ KƚŚĞƌ͗ EĂŵĞ͗ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ ŽŶƚĂĐƚη͗ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ ĂƚĞ͗ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ K&ƵƚŚŽƌŝnjĂƚŝŽŶ hƉĚĂƚĞĚ͗ϬϴͬϯϬͬϮϬϮϭ 1806 W 15th St & Unit #25/1/2025 Page 1 of 1 EXISTING ONE & TWO FAMILY DWELLINGS ELECTRICAL SERVICES UNDERGROUND EXCEPTION CEC 2022 ELC-04 All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41- 626(b). There is a standing exception for one and two family dwellings. This exception applies only when the new electrical service is designed to be fed from below grade as well as overhead. This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the circuit breaker side of this cabinet. Only listed combination overhead and underground feed service boxes may be used to connect to an overhead utility drop. This exception to an underground fed service applies only to existing single family and two family residences. Planning & Building Agency Permits & Plan Check Section 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 Rigid Conduit Service Entrance Conductor Riser Underground Service Lateral METER Rev. 1/21/2020 1806 W 15th St & Unit #25/1/2025 1806 W 15th St & Unit #25/1/2025