Laserfiche WebLink
Section Identification <br />Office <br />101 <br />2 <br />3 <br />A-7 <br />A <br />A <br />1 <br />A-4 <br />A-3 <br />Sht. Where Sect. is Drawn <br />Detail Identification <br />Sht. Where Sect. is Drawn <br />Elevation Number <br />Sht. Where Sect. Is Drawn <br />Row Designation <br />Elevation Symbol <br />Room Number <br />Room Name <br />Detail Symbol <br />1 <br />A <br />4 <br />3 <br />100 <br />A <br />Revision Number <br />Revision Symbol <br />Demolition Symbol <br />Demolition Symbol <br />Equipment Number <br />Equipment Symbol <br />Section Symbol <br />Door Number <br />Door Symbol <br />Column or Reference Lines <br />JOB NO.SCALE <br />AS NOTED <br />SHEET NO. <br />SHEET TITLE. <br />APPROVALS: <br />THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF <br />THE DRAFTER AND MAY NOT BE REPRODUCED WITHOUT THE <br />DESIGNERS PERMISSION AND UNLESS THE REPRODUCTION CARRIES <br />THE DRAFTERS NAME. ALL DESIGN AND OTHER INFORMATION SHOWN <br />ON THE DRAWINGS ARE FOR USE ON THE SPECIFIC PROJECT ONLY <br />AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION <br />FROM THE DRAFTER. <br />[DESIGN GROUP NAME][DESIGN GROUP NAME][DESIGN GROUP NAME][DESIGN GROUP NAME] <br />1610 W. 7TH ST. LOS ANGELES, CA. 90017 <br />benny@designgroupname.com <br />marino@designgroupname.com <br />8/ <br />2 <br />7 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />7 <br />: <br />4 <br />3 <br />: <br />5 <br />8 <br /> <br />A <br />M <br />T-0.0 <br />COVER PAGE <br />[DGN-2200] <br />1621 w 10th ST. & #2 <br />SANTA ANA, CA. <br />10th ADU <br />No. Description Date <br />3 B&S - REV 1 08 21 24 <br />10TH ADU <br />1621 W 10TH ST. & #2 <br />SANTA ANA, CA. <br />CONTRACTOR TO VERIFY ALL DIMENSION WITH DESIGNER PRIOR TO COMMENCING WORK, DESIGNER WILL NOT BE LIABLE FOR ANY MISTAKES DONE ON SITE WITHOUT VERIFYING WITH DESIGNER. <br />DRAWINGS SHOULD NOT BE SCALED AS THEY MAY DIFFER DUE TO REPROGRAPHICAL ERRORS. <br />THESE DRAWINGS ARE PREPARED UNDER CALIFORNIA BUSINESS & PROFESSIONS CODE 5537: <br />A. THIS CHAPTER DOES NOT PROHIBIT ANY PERSON FROM PREPARING PLANS, DRAWINGS, OR SPECIFICATIONS FOR ANY OF <br />THE FOLLOWING: <br />1.1. SINGLE-FAMILY DWELLINGS OF WOODFRAME CONSTRUCTION NOT MORE THAN TWO STORIES AND BASEMENT IN HEIGHT. <br />1.2. MULTIPLE DWELLINGS CONTAINING NO MORE THAN FOUR DWELLING UNITS OF WOODFRAME CONSTRUCTION NOT MORE <br />THAN TWO STORIES AND BASEMENT IN HEIGHT. HOWEVER, THIS PARAGRAPH SHALL NOT BE CONSTRUED AS ALLOWING AN <br />UNLICENSED PERSON TO DESIGN MULTIPLE CLUSTERS OF UP TO FOUR DWELLING UNITS EACH TO FORM APARTMENT OR <br />CONDOMINIUM COMPLEXES WHERE THE TOTAL EXCEEDS FOUR UNITS ON ANY LAWFULLY DIVIDED LOT. <br />1.3. GARAGES OR OTHER STRUCTURES APPURTENANT TO BUILDINGS DESCRIBED UNDER SUBDIVISION (A), OF WOODFRAME <br />CONSTRUCTION NOT MORE THAN TWO STORIES AND BASEMENT IN HEIGHT <br />1.4. AGRICULTURAL AND RANCH BUILDINGS OF WOODFRAME CONSTRUCTION, UNLESS THE BUILDING OFFICIAL HAVING <br />JURISDICTION DEEMS THAT AN UNDUE RISK TO THE PUBLIC HEALTH, SAFETY, OR WELFARE IS INVOLVED. <br />B. IF ANY PORTION OF ANY STRUCTURE EXEMPTED BY THIS SECTION DEVIATES FROM SUBSTANTIAL COMPLIANCE WITH <br />CONVENTIONAL FRAMING REQUIREMENTS FOR WOODFRAME CONSTRUCTION FOUND IN THE MOST RECENT EDITION OF <br />TITLE 24 OF THE CALIFORNIA CODE OF REGULATIONS OR TABLES OF LIMITATION FOR WOODFRAME CONSTRUCTION, AS <br />DEFINED BY THE APPLICABLE BUILDING CODE DULY ADOPTED BY THE LOCAL JURISDICTION OR THE STATE, THE BUILDING <br />OFFICIAL HAVING JURISDICTION SHALL REQUIRE THE PREPARATION OF PLANS, DRAWINGS, SPECIFICATIONS, OR <br />CALCULATIONS FOR THAT PORTION BY, OR UNDER THE RESPONSIBLE CONTROL OF, A LICENSED ARCHITECT OR <br />REGISTERED ENGINEER. THE DOCUMENTS FOR THAT PORTION SHALL BEAR THE STAMP AND SIGNATURE OF THE LICENSEE <br />WHO IS RESPONSIBLE FOR THEIR PREPARATION. SUBSTANTIAL COMPLIANCE FOR PURPOSES OF THIS SECTION IS NOT <br />INTENDED TO RESTRICT THE ABILITY OF THE BUILDING OFFICIALS TO APPROVE PLANS PURSUANT TO EXISTING LAW AND IS <br />ONLY INTENDED TO CLARIFY THE INTENT OF CHAPTER 405 OF THE STATUTES OF 1985.(AMENDED BY STATS. 1996, CH. 184, <br />SEC. 8. EFFECTIVE JANUARY 1, 1997.) <br />1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO ANY WORK AND SHALL NOTIFY THE DESIGNER OF <br />ANY DISCREPANCY. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REPAIRS REQUIRED DUE TO HIS FAILURE TO DO SO. <br />CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING, COORDINATING, AND SCHEDULING OF ALL INSPECTIONS AND <br />TESTS INDICATED ON THE PLANS AND SPECIFICATIONS RECOMMENDED BY THE SOILS REPORT AND/OR REQUIRED BY ANY <br />GOVERNMENTAL AGENCY. CONTRACTOR SHALL VERIFY THE SIZE AND LOCATION OF ALL UTILITY LINES AND STUBS TO THE <br />BUILDING (S) AS MAY BE INDICATED ON THE PLANS. CONTRACTOR SHALL BE REQUIRED TO BRING ALL UTILITY LINES <br />(WATER, SEWER (S), GAS, AND ELECTRICAL), TO WITHIN 5'-0" OF THE BUILDING TO TERMINATION POINTS AS INDICATED ON <br />THE PLANS READY FOR CONNECTION. <br />2. THE CONTRACTOR WILL PROVIDE THE OWNER WITH A LETTER OF CERTIFICATION PREPARED IMMEDIATELY AFTER <br />FOOTINGS ARE PLACED, TO CONFIRM THAT THE LOCATION OF FOOTINGS COMPLY WITH THE APPROVED SITE DRAWINGS. <br />THIS SHALL BE DONE BY THE SITE CIVIL ENGINEER AT THE CONTRACTORS EXPENSE. ANY DISCREPANCIES FROM THE <br />APPROVED BUILDING LOCATION WILL BE REMOVED AT THE CONTRACTORS EXPENSE. <br />3. ALL REVISIONS TO THE DRAWINGS MUST PROCEED THROUGH NORMAL CHANNELS. <br />4. ALL WALL FRAMING SHALL BE 2 X 4 WOOD STUDS AT 16" O.C. UNLESS OTHERWISE NOTED. 2X6 WOOD STUDS SHALL BE USED <br />FOR WALLS RECEIVING HEAVY PLUMBING, ELECTRICAL PANELS, OR CONCEALING PIPE COLUMNS. ALL STUDS OVER 14"-0" <br />HEIGHT SHALL BE 2 X 6. SEE STRUCTURAL. <br />5. NO ADDITIONAL ROOF OPENINGS OR ROOF MOUNTED EQUIPMENT ARE ALLOWED BEYOND THAT WHICH IS SHOWN ON <br />THESE PLANS WITHOUT WRITTEN CONSENT OF THE DESIGNER AND THE STRUCTURAL ENGINEER. <br />6. BUILDING PADS CONSTRUCTED PER SOILS ENGINEERS SPECIFICATIONS ARE ASSUMED TO BE AT + 0.10 FT. OF THE <br />ELEVATIONS SHOWN ON THE PLANS. CONTRACTOR SHALL NOTIFY DESIGNER/ENGINEER OF ANY DISCREPANCIES UPON <br />VERIFICATION. <br />7. COVER ALL CONCRETE SLAB SURFACES WITH CURING PAPER BEFORE STARTING ADJACENT CONCRETE SLABS. CONCRETE <br />CONTRACTOR SHALL BE RESPONSIBLE FOR SPLASHING OF FRESH CONCRETE SEE SPECIFICATIONS. <br />8. PAVING SHALL BE ACCOMPLISHED ACCORDING TO THE SITE PAVING SPECIFICATIONS AND THE SOILS REPORT AND SHALL <br />BE OF THE SAME SECTION AND DRAINAGE SCHEME AS ADJACENT PAVED AREAS. THE BUILDING CONTRACTOR SHALL BE <br />RESPONSIBLE FOR THE A.C. OR CONCRETE PAVING, ON AND OFF SITE. IF THE EXISTING PAVING FALLS SHORT OF THE <br />BUILDING LINE, OR IF A PORTION OR SECTION OF THE EXISTING PAVING NEEDS TO BE REMOVED FOR CONSTRUCTION <br />PURPOSE, THE BUILDING CONTRACTOR SHALL, AT THE APPROPRIATE TIME, REPLACE THE A.C. PAVING TO THE BUILDING <br />LINE. THICKNESS OF THE A.C. PAVING BASE MATERIAL AND ALL OTHER ASPECTS SHALL MATCH EXISTING OTHER <br />ASSOCIATED PERMANENT IMPROVEMENTS SUCH AS CONCRETE CURBS, WHEELSTOPS, PLANTING AND IRRIGATION OF <br />DISTURBED OR DAMAGE DURING THE CONSTRUCTION PROCESS SHALL LIKEWISE BE REPLACED AND RESTORED INCLUDING <br />PAVEMENT STRIPING. PER APWA STANDARD PLANS AND CITY STANDARDS. <br />9. ALL MATERIALS AND WORK SHALL CONFORM TO LATEST GOVERNING BUILDING CODES AND REGULATIONS. <br />GENERAL NOTES <br />BUILDING & SITE DATA <br />FLOOR AREA BREAKDOWN <br />APPLICABLE CODES <br />ABBREVIATIONS <br />SYMBOL DEFINITIONS SHEET INDEX <br />SETBACKS & RESTRICTIONS <br />VICINITY MAP <br />CONSULTANT LIST <br />SCOPE OF WORK <br />• 215 SF CONVERSION FROM 1-CAR GARAGE TO ADU - ADD TO 278 SF EXISTING GUEST HOUSE <br />• EXISTING GUEST HOUSE - BED & BATH ADDITION IN 1972 - #8394 <br />• DEMO EXISTING COVERED PATIO - NON PERMITTED <br />ABV. - Above <br />A.B. - Anchor Bolt <br />A/C - Air Conditioner <br />A.D. - Access Door <br />ADD. - Addition <br />ADJ. - Adjust <br />A.F.F. - Above Finished Floor <br />A.F.G. - Above Finished Grade <br />A.G. - Above Grade <br />ALT. - Alternate <br />APP'D. - Approved <br />ARCH. - Architect, <br />Architectural <br />ASPH. - Asphalt <br />B <br />B.C. - Bookcase <br />BD. - Board <br />B.L. - Building Line <br />BLDG. - Building <br />BLK. - Block <br />BM. - Beam <br />B.N. - Boundary nailing <br />B.O. - Bottom of <br />B.O.F. - Bottom of footing <br />B.O.W. - Bottom of wall <br />BRG. - Bearing <br />B.U. - Built up <br />BTM. - Bottom <br />C <br />CSMNT. - Casement <br />CABT. - Cabinet <br />C.B. - Catch Basin <br />C.D. - Construction document <br />CEM. - Cement <br />C.F.M. - Cubic Feet per Minute <br />C.L. - Center Line <br />CH. - Channel <br />C.I. - Cast Iron <br />C.I.P. - Cast in Place <br />CL. - Closet <br />CLG. - Ceiling <br />C.O. - Clean Out <br />C.O. - Cased Opening <br />COL. - Column <br />CONT. - Continuous <br />CONTR. - Contractor <br />CONC. - Concrete <br />C.T. - Ceramic Tile <br />D <br />D.S. - Down spout <br />D/W - Dishwasher <br />DBL. - Double <br />DEMO. - Demolition <br />DIA. - Diameter <br />DIM. - Dimension <br />D.L. - Dead Load <br />DN. - Down <br />DR. - Door <br />E <br />EA. - Each <br />E.F. - Exhaust fan <br />E.J. - Expansion joint <br />E.N. - End nailing <br />ELEV. - Elevation <br />ELECT. - Electric, electrical <br />EQ. - Equal <br />EQUIP. - Equipment <br />EST. - Estimate <br />E.W. - Each way <br />EXH. - Exhaust <br />EXIST. - Existing <br />EXT. - Exterior <br />N <br />N.T.S. - Not to scale <br />N.C.M. - Non-corrosive metal <br />N.F.C. - Not for construction <br />NLR. - Nailer <br />NO. - Number <br />NOM. - Nominal <br />O <br />O.C. - On center <br />O.D. - Outside diameter <br />O.R. - Outside radius <br />O.H. - Overhead <br />OPNG. - Opening <br />P <br />P. - Paint <br />PART. - Partition <br />PAV. - Pavement <br />P.C. - Pre-Cast Concrete <br />PERF. - Perforated <br />PL. - Plaster <br />PLT. - Plate <br />P.L. - Property line <br />PLAS. - Plastic <br />P.L.V. - Plastic laminate veneer <br />PLYWD. - Plywood <br />PORC. - Porcelain <br />P.S.F. - Pounds per square foot <br />P.S.I. - Pounds per square inch <br />P.V.C. - Polyvinyl chloride <br />PWR. - Power <br />Q <br />Q.T. - Quarry tile <br />QTY. - Quantity <br />R <br />RAD. - Radius <br />R.D. - Roof drain <br />R.D.L. - Roof drain leader <br />R.O. - Rough Opening <br />R.O.W. - Right of way <br />REFG. - Refrigerator <br />REF. - Reference <br />REINF. - Reinforced <br />RET. - Return <br />REV. - Revision <br />RM. - Room <br />RMV. - Remove <br />S <br />SAN. - Sanitary <br />S.C. - Solid core <br />S.C. - Self-Closing <br />SCHED. - Schedule <br />S.D. - Smoke detector <br />SECT. - Section <br />SHT. - Sheet <br />SHT'G. - Sheathing <br />SIM. - Similar <br />SPECS. - Specifications <br />SQ.FT. - Square feet <br />SQ. IN. - Square inches <br />STD. - Standard <br />STL. - Steel <br />S.Y. - Square yard <br />SYS. - System <br />T <br />T&G - Tongue and groove <br />T.B. - Through bolt <br />T.O. - Top of <br />T.O.B. - Top of Beam <br />T.O.C. - Top of curb <br />T.O.F. - Top of footing <br />T.O.J. - Top of joist <br />T.O.M. - Top of masonry <br />T.O.W. - Top of wall <br />T.S. - Tube steel <br />TH. - Threshold <br />THR. - Threaded <br />TYP. - Typical <br />U <br />UNF. - Unfinished <br />F <br />F.A. - Fire alarm <br />F.C.O. - Floor clean out <br />F.D. - Floor drain <br />F.E. - Fire extinguisher <br />F.N. - Field nailing <br />FAB. - Fabricate <br />FDN. - Foundation <br />FIN. - Finish <br />FLR. - Floor <br />FLG. - Flooring <br />FLUOR. - Fluorescent <br />FURN. - Furnace <br />G <br />GA. - Gauge <br />GALV. - Galvanized <br />GAR. - Garage <br />G.C. - General Contractor <br />G.F.C.I. - Ground Fault Circuit Interrupt <br />G.F.I. - Ground Fault Interrupt <br />GL. - Glass <br />G.M. - Grade mark <br />GR. - Grille <br />G.T. - Glazed tile <br />GYP. - Gypsum <br />H <br />H.B. - Hose bib <br />H.C. - Hollow core <br />HDBD. - Hardboard <br />HDW. - Hardware <br />HGT. - Height <br />HOR. - Horizontal <br />HR. - Hour <br />H.R. - Handrail <br />HTR. - Heater <br />H.V.A.C. - Heating, Venting and Air <br />Conditioning <br />H.W. - Hot water <br />I <br />I.C.F. - Insulated Concrete Form <br />I.D. - Inside diameter <br />I.F. - Inside Face <br />INCL. - Inclusive, including <br />INV. - Invert <br />INSUL. - Insulation <br />INT. - Interior <br />J <br />J-Box - Junction box <br />JCT. - Junction <br />JST. - Joist <br />K <br />K.-D. - Knock Down <br />K.D. - Kiln dried <br />K.O. - Knock out <br />L <br />LFT. - Linear feet <br />LAM. - Laminate <br />LAT. - Lateral <br />LAV. - Lavatory <br />LD. - Lead <br />LIN. - Linear <br />LINO. - Linoleum <br />LT. - Light <br />LTG. - Lighting <br />L.V.L. - Laminated Veneer Lumber <br />M <br />M.B. - Machine bolt <br />M.O. - Masonry opening <br />MAR. - Marble <br />MAS. - Masonry <br />MTL. - Material <br />MAX. - Maximum <br />MECH. - Mechanical <br />MED. - Medium <br />MFG. - Manufacturing <br />MIN. - Minimum <br />MOD. - Modular <br />MTL. - Metal (steel) <br />MUL. - Mullion <br />V <br />V.B. - Vapor barrier <br />V.I.F. - Verify in field <br />VA. - Voltage <br />VCT. - Vinyl composition tile <br />W <br />W.C. - Toilet (water closet) <br />WDW. - Window <br />WCT. - Wainscot <br />WP. - Weatherproof <br />WT. - Weight <br />WTR. HTR. - Water Heater <br />WD. - Wood <br />W.I. - Wrought Iron <br />W.I.C. - Walk In Closet <br />Y <br />YD. - Yard <br />SHEET INDEX <br />NUMBER SHEET NAME <br />T-0.0 COVER PAGE <br />T-0.1 RESIDENTIAL NOTES <br />T-1.0 CODE ANALYSIS <br />T-2.0 ATTACHMENTS <br />ARCHITECTURAL <br />A-0.0 SITE PLAN <br />A-0.1 ROOF PLAN <br />A-0.2 EXISTING RESIDENCE <br />A-1.0 EXISTING / DEMO FLOOR PLAN <br />A-2.0 PROPOSED FLOOR PLAN <br />A-5.0 SECTIONS <br />A-6.0 DOOR & WINDOW SCHEDULE <br />AD-1.0 DETAILS <br />STRUCTURAL <br />S-1 STRUCTURAL <br />S-2 STRUCTURAL <br />S-3 STRUCTURAL <br />S-4 STRUCTURAL <br />S-5 STRUCTURAL <br />T24 <br />T-24.1 T24 COMPLIANCE FORMS <br />T-24.2 T24 COMPLIANCE FORMS <br />ALL WORK SHALL COMPLY WITH THE FOLLOWING CODES TO INCLUDE LOCAL AMENDMENTS" <br />2022 CALIFORNIA RESIDENTIAL CODE, PART 2.5 <br />2022 CALIFORNIA BUILDING CODE, PART 2,8 & 10 <br />2022 CALIFORNIA ELECTRICAL CODE PART 3 <br />2022 CALIFORNIA MECHANICAL CODE PART 4 <br />2022 CALIFORNIA PLUMBING CODE, PART 5 <br />2022 CALIFORNIA ENERGY CODE PART 6 <br />2022 CALIFORNIA FIRE CODE, PART 9 <br />LOCATION EXISTING PROPOSED TOTAL <br />(E) RESIDENCE 1601 SF (0 SF)1601 SF <br />(E) CARPORT 252 SF (0 SF)252 SF <br />(E) GUEST HOUSE 278 SF (0 SF)278 SF <br />(E) GARAGE (CONV.) 215 SF (215 SF)215 SF <br />FOOTPRINT 2,346 SF <br />LOT SIZE 8,297 SF <br />LOT COVERAGE 2346 SF / 8297 SF = .28 = 28% <br />ADU / SFR 493/1601 = 31% <br />DEVELOPMENT STANDARDS: <br />SETBACKS: <br />20'-0" FRONT YARD <br />4'-0" SIDE YARD <br />4'-0" REAR YARD <br />HEIGHT: <br />27'-0" - MAX <br />15'-0" ACTUAL <br />LOT COVERAGE: <br />35% <br />PARKING REQUIREMENTS: <br />1 SPACE PER UNIT UNLESS WITHING 1/2 MILE OF A <br />TRANSIT STOP - SEE ATTACHEMENT ON T-2.0 <br />PARKING SPACES PROVIDED: <br />NO CHANGE IN PARKING <br />PARKING DESIGN: AS EXISTING <br />BUILDING SEPARATION: <br />10' - 0" MIN. <br />16' - 5" ACTUAL <br />ZONE:R1 <br />APN:405-141-13 <br />LOT AREA:8,297 SF. <br />BUILDING OCCUPANCY GROUP:R3 <br />CONSTRUCTION TYPE:TYPE V-B <br />SPRINKLER SYSTEM:NO, (E) SFR NON-SPRINKLERED <br />BUILDING HEIGHT:15'-0" - 1 STORY <br />HIGH FIRE SEVERITY ZONE:N/A <br />PROJECTIONS:N/A <br />LEGAL DESCRIPTION:N-TRACT: 1144 BLOCK:LOT: 4 <br />FEMA DESIGNATED FLOOD ZONE:X <br />Area Schedule (PROPOSED) <br />Name Area <br />1ST FLOOR <br />(E) GARAGE - CONVERSION 215 SF <br />(E) GUEST HOUSE 278 SF <br />(E) SFR - CARPORT 252 SF <br />(E) SFR - HOUSE 1601 SF <br />OWNER <br />MCAR INVESTMENTS, LLC. <br />MARCELO GIGLIO <br />315 VILLANOVA RD <br />COSTA MESA, CA. 92626 <br />DESIGNER <br />BENNY ARIAS <br />3111 FRAZIER ST. <br />BALDWIN PARK, CA. 91706 <br />(T) 626.485.2843 <br />[design group name] <br />STRUCTURAL ENGINEER <br />KTW SOLUTIONS <br />TAEWON KIM, P.E. <br />28531 PALOS VERDES DR. #E <br />RANCHO PALOS VERDES, CA. 90275 <br />(T) 310.986.2185 <br />(E) KTWENGCAL@GMAIL.COM <br />T24 ENGINEER <br />TITLE 24 GUYS <br />10964 MEMORY PARK AVE <br />MISSION HILLS, CA. 91345 <br />(E) GILBERTO@TITLE24GUYS.COM <br />THE ADU SF / SFD SF RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN “SFR SF” OF THE EXISTING PRIMARY <br />RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN “SFR SF” OF THE EXISTING RESIDENCE <br />"REDGUARD IS REQUIRED IN THE GARAGE IF <br />EXISTING WATERPROOFING IN NOT VERIFIED." <br />BLDG # 101119850-51 <br /> <br />APPROVALS <br />BLDG - CSG Consultants <br />PLNG - PRaj <br />POLICE - BMartin <br />1621 W Tenth St & <br />#29/30/2024