Loading...
HomeMy WebLinkAbout1401 S Rosewood Ave Unit# 2& 3 - Plan1401 S ROSEWOOD AVE, JADU #2 & ADU #3 SANTA ANA, CALIFORNIA 92707 A.B. A/C ALUM. A.N.G. ARCH. BD. BLDG. BLK. BLK'G. B.W. C. C.L. CLR. C.O. CONC. CONT. CSB. D. DBL. DN DWG D.S. DWR. EL. EXIST'G., (E) EXT. F.F. F.G. FIN. FL. F.O.S. F.P. F.S. FT. GA. GALV. GR. GYP. H.C. HORIZ. INT. INV. MANFG. MANUF. MAX. MECH. MIN. M.T. (N) N.G. N.I.C. N.T.S. O.H. P.C. PL,P.L. P&S PYWD. REC. REINF. R'M R.S. S. S.C. SCH. SIM. STD. STL. STRUC. SQ. T.C. T&G THK. THRU T.O.P. T.O.S. T.W. TYP. VERT. W. W/ W/IN W/O WD. WP. ANCHOR BOLT AIR CONDITIONING ALUMINUM AVERAGE NATURAL GRADE ARCHITECTURAL BOARD BUILDING BLOCK BLOCKING BACK OF WALL COMPACT CENTER LINE CLEAR CLEAR OUT CONCRETE CONTINUOUS CONCRETE SPLASH BLOCK DRYER DOUBLE DOWN DRAWING DOWN SPOUT DRAWER ELEVATION EXISTING EXTERIOR FINISHED FLOOR FIXED GLASS FINISH/FINISHED FLOOR FACE OF STUD OR STRUCTURE FIXED PANEL FINISHED SURFACE FOOT/FEET GAUGE GALVANIZED GRADE GYPSUM HOLLOW CORE HORIZONTAL INTERIOR INVERT MANUFACTURING MANUFACTURER MAXIMUM MECHANICAL MINIMUM METAL THRESHOLD NEW NATURAL GRADE NOT IN CONTRACT NOT TO SCALE OVERHANG PULL CORD PROPERTY LINE POLE AND SHELF PLYWOOD RECREATION REINFORCED ROOM ROUGH SWAN STANDARD SOLID CORE SCHEDULE SIMILAR STANDARD STEEL STRUCTURAL SQUARE TOP OF CURB TONGUE & GROOVE THICK THROUGH TOP OF PLATE TOP OF SLAB TOP OF WALL TYPICAL VERTICAL WASHER WITH WITHIN WITHOUT WOOD WATERPROOF OR WEATHERPROOF WALL LINE: NUMBERS VERTICAL LETTERS HORIZONTAL DOOR SYMBOL NUMBERS WINDOW TYPE - LETTERS DETAIL DETAIL IDENTIFICATION SHEET WHERE DETAIL IS DRAWN SECTION SECTION IDENTIFICATION SHEET WHERE SECTION IS DRAWN INTERIOR ELEVATIONELEVATION IDENTIFICATION SHEAR WALL-LETTERS REVISION - NUMBERS CLOUD AROUND REVISION OPTICAL MATCH LINE SHADED PORTION IS THE SIDE CONSIDERED WORK POINT NEW OR FINISHED CONTOURS EXISTING CONTOURS PROPERTY LINE CENTER LINE SHEET WHERE DETAIL IS DRAWN DETAIL IDENTIFICATION SECTIONAL DETAIL ABBREVIATIONS LEGEND MATERIALS BUILDING DATA BUILDING DATA: VICINITY MAP PROJECT FRONT ELEVATION LOT SIZE: 7,061 SQ.FT. ZONING: R-1 USE OF EXISTING BUILDING: SINGLE FAMILY RESIDENCE LEGAL DESCRIPTION: APN: 013-051-01 N TR 1373 BLK LOT 12 MAP REFERENCE: MM 41/19 OF COUNTY OF ORANGE. SCOPE OF WORK: -ONE 750 S.F. ATTACHED A.D.U. & ONE 500 S.F. ADDITION TO BE JADU PER CALIFORNIA GOVERNMENT CODE -DEMOLISH ONE EXISTING 358 S.F. GARAGE -DEMOLISH TWO EXISTING PATIO COVERS, 198 S.F. & 259 S.F. APPLICABLE CODES: -2022 CALIFORNIA RESIDENTIAL CODE (CRC) -2022 CALIFORNIA MECHANICAL CODE (CMC) -2022 CALIFORNIA PLUMBING CODE (CPC) -2022 CALIFORNIA ELECTRICAL CODE (CEC) -2022 CALIFORNIA GREEN BUILDING STANDARDS CODE ( CGBSC) -2022 CALIFORNIA ENERGY CODE (CEnC) -CITY OF SANTA ANA MUNICIPAL CODE ARCHITECTURAL SHEET INDEX TYPE OF CONSTRUCTION: V-B EXISTING LOT COVERAGE EXISTING SINGLE FAMILY DWELLING: 1,160 S.F. EXISTING DETACHED GARAGE: 358 S.F. PATIO COVER #1: 198 S.F. PATIO COVER #2: 259 S.F. 1,975 S.F. / 7,061 S.F. = 27% MAXIMUM ALLOWED LOT COVERAGE PER ZONING CODE: 35% 7,061 * 35% ~ 2,471,35 S.F. PROPOSED LOT COVERAGE: SINGLE FAMILY DWELLING: 1,160 S.F. ADDITION TO BECOME JADU UNIT #2: 500 S.F. ATTACHED A.D.U. UNIT #3: 750 S.F. 2,410 S.F. / 7,061 S.F. = 34% SQUARE FOOTAGE RATIO ADU 750 S.F./ S.F.R. 1,160 S.F.= 64% JADU 500 S.F./S.F.R. 1,160 S.F.= 43% NOTE: THE ADU SF / SFD SF RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN S.F. AREA€€ OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN S.F. AREA. PARKING REQUIREMENT: NONE, PROPERTY LOCATED WITHIN 1/2 MILE DISTANCE FROM TRANSIT STOP PROPERTY NO FIRE SPRINKLERS ARE CURRENTLY INSTALLED TRANSIT-STOP MAP-PROPERTY 0.15 MILE AWAY FROM TRANSIT-STOP OCCUPANCY GROUP: R-3/U NUMBER OF STORIES: ONE FLOOD ZONE: X STRUCTURAL TITLE 24 CITY OF SANTA ANA NOTE: MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT PART OF THIS PLAN REVIEW AND APPROVAL. THE BUILDING AND SAFETY DIVISION PLAN REVIEW DOES NOT INCLUDE POTENTIAL ELECTRICAL, WATER, OR GAS REVISIONS REQUIRED BY ANY NON-CITY UTILITY COMPANY. IT IS SOLELY ON THE CONTRACTOR TO ENSURE PROPOSED ADDITION OR ALTERATION CAN AND WILL MEET UTILITY COMPANY REQUIREMENTS. MEP ARE SUBJECT TO BUILDING FIELD INSPECTION. DEFERRED ITEMS -PV SYSTEM- SEE TITLE 24 FOR REQUIREMENTS -TRUSSES: a. SUBMIT TWO (2) SETS OF TRUSS CALCULATIONS AND PLANS TO THE CITY FOR PLAN CHECK. b. THE TRUSS CALCULATIONS AND PLANS SHALL INCLUDE REVIEW OF ROOF, MECHANICAL AND LATERAL LOADS (CHORD/STRUT & BRACE LOADS); ALSO INCLUDE REVIEW OF TOP CHORD AND BOTTOM CHORD FOR AXIAL + FLEXURE BETWEEN PANEL JOINTS. c. THE TRUSS CALCULATIONS AND PLANS SHALL BE STAMPED, SIGNED AND DATED BY A LICENSED CIVIL/STRUCTURAL ENGINEER. d. THE TRUSS PLANS SHALL BE “REVIEW STAMPED” AND “WET” SIGNED BY THE ENGINEER OF RECORD. - APPROVED PLANS TO BE SUBMITTED TO PUBLIC WORKS DIVISION FOR A FORMAL PLAN CHECK REVIEW FOR AN ENCROACHMENT PERMIT IN ORDER TO UPGRADE WATER SERVICE AND WATER METER. A - 000 Scale Project number Date Drawn by Checked by Consultant Address Address Phone e-mail Consultant Address Address Phone e-mail 2023- 015 08-16-24 H.M.F. & M.O. N/A 14 0 1 S R o s e w o o d A v e . Sa n t a A n a , C A 9 2 7 0 7 fo.studio11@gmail.com Henry M Funes (562) 572-4620 Maria Ornelas Funes (323) 715-1877 10929 S Burin Ave Inglewood, CA. 90304 No. Description Date Cover Sheet He c t o r H e r n a n d e z Ow n e r Consultant Address Address Phone e-mail 50 0 S . F . J A D U U N I T # 2 & 7 5 0 A D U U N I T # 3 950 E 3rd St. Unit 4104 Los Angeles CA 90013 Bldg #'s 101119241-43 APPROVALS: PLNG - F. Arias BLDG - J. Lo POLICE - B. Martin PUBLIC WORKS - Y. Soto 1401 S Rosewood Ave Unit# 2& 34/22/2025 Borchard Ave. S R o s e w o o d A v e . 30 ' - 0 " 30' - 0" 56 ' - 6 1 9 / 3 2 " 125' - 0" 29' - 4" 10 ' - 0 " EXISTING SINGLE FAMILY RESIDENCE 1160 SQFT. EXISTING DETACHED GARAGE TO BE DEMO 358 SQFT. EXISTING PATIO COVER TO BE DEMO 259 SQFT. EXISTING PATIO COVER TO BE DEMO 198 SQFT. Scale Project number Date Drawn by Checked by Consultant Address Address Phone e-mail Consultant Address Address Phone e-mail fo.studio11@gmail.com Henry M Funes (562) 572-4620 Maria Ornelas Funes (323) 715-1877 950 E 3rd St. Unit 4104 Los Angeles CA 90013 Ow n e r Consultant Address Address Phone e-mail 3/16" = 1'-0" 9/ 2 4 / 2 0 2 4 1 : 5 6 : 4 1 A M A101 2023-015 April 17, 2024 Author Checker 14 0 1 S R o s e w o o d A v e S a n t a A n a , C A 92 7 0 7 Existing Site Plan He c t o r H e r n a n d e z 75 0 S . F . A D U & 5 0 0 S . F . J A D U No.Description Date 3/16" = 1'-0"1 Existing Site 1401 S Rosewood Ave Unit# 2& 34/22/2025 Borchard Ave. S R o s e w o o d A v e . 30 ' - 0 " 30' - 0" 56 ' - 6 1 9 / 3 2 " 125' - 0" 25' - 2" 7' - 7 " 29' - 4" 10 ' - 0 " 10 ' - 0 " 15 ' - 1 1 9 / 3 2 " EXISTING SINGLE FAMILY RESIDENCD 1160 SQFT. PROPOSED ADDITION FOR JADU OF 500 SQ.FT. PROPOSED ADU 750 SQ.FT. NEW LANDSCAPEE. LANDSACPE 2% S L O P E 2% SLO P E 2% SLO P E 2% SL O P E 2% SLO P E 2% SLO P E 2% SL O P E 2% SL O P E 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E 2% S L O P E Scale Project number Date Drawn by Checked by Consultant Address Address Phone e-mail Consultant Address Address Phone e-mail fo.studio11@gmail.com Henry M Funes (562) 572-4620 Maria Ornelas Funes (323) 715-1877 10929 S Burin Ave Inglewood, CA. 90304 Ow n e r Consultant Address Address Phone e-mail 3/16" = 1'-0" 11 / 6 / 2 0 2 4 1 : 2 4 : 3 6 A M A102 2023-015 April 17, 2024 HMF & MO 14 0 1 S R o s e w o o d A v e S a n t a A n a , C A 92 7 0 7 Site Plan He c t o r H e r n a n d e z 75 0 S . F . A D U & 5 0 0 S . F . J A D U No.Description Date 3/16" = 1'-0"1 Site CL CL CL CL 1401 S Rosewood Ave Unit# 2& 34/22/2025 SINGLE FAMILY RESIDENCE 1160 SQ.FT. GARAGE 358 SQ.FT. LIVING ROOM BEDROOM BEDROOM BEDROOM BATH ROOM KITCHEN DINNING ROOM DEMO WINDOW DEMO WINDOW WINDOW 2'-10" X 3'-10" TO REMAIN DEMO WINDOW DEMO DOOR DEMO WALL DEMO DOOR PATIO COVER TO BE DEMO EXISTING PATIO COVER TO BE DEMO Scale Project number Date Drawn by Checked by Consultant Address Address Phone e-mail Consultant Address Address Phone e-mail fo.studio11@gmail.com Henry M Funes (562) 572-4620 Maria Ornelas Funes (323) 715-1877 10929 S Burin Ave Inglewood, CA. 90304 Ow n e r Consultant Address Address Phone e-mail 1/4" = 1'-0" 9/ 2 4 / 2 0 2 4 1 : 5 6 : 4 5 A M A201 2023-015 April 17, 2024 Author Checker 14 0 1 S R o s e w o o d A v e S a n t a A n a , C A 92 7 0 7 Existing & Demo He c t o r H e r n a n d e z 75 0 S . F . A D U & 5 0 0 S . F . J A D U No.Description Date 1/4" = 1'-0"1 Exiting & Demo Plan 950 E 3rd St. Unit 4104 Los Angeles CA 90013 1401 S Rosewood Ave Unit# 2& 34/22/2025 EXISTING SINGLE FAMILY RESIDENCE 1160 SQFT. 5 A402 6 A402 38 ' - 1 1 1 9 / 3 2 " 14 ' - 2 " 8' - 5 " 3' - 1 0 " 12 ' - 6 1 9 / 3 2 " 3' - 6"6' - 6"16' - 2"2' - 10"10' - 0" 11 ' - 4 " 2' - 5 " 4' - 7"5' - 5"16' - 2"4' - 0"3' - 5"5' - 5" 16' - 4"23' - 6" 5' - 5"5' - 3"12' - 10" 2' - 6"2' - 11" 6' - 5"7' - 8"2' - 3" 7' - 6 1 9 / 3 2 " 11 ' - 8 " 8' - 5 " 11 ' - 4 " 10 ' - 0 " 8' - 5 " 21 ' - 0 " 12 ' - 0 " 1' - 3 " 2' - 6 " 1' - 3 " 3' - 0 " 1' - 3 " 3' - 0 " 1' - 3 " 2' - 6 " 10 ' - 0 " 10' - 0" 4' - 4 " 4' - 6 " 3' - 1 1 " 7' - 0 " 10 ' - 0 " 7' - 7 " 5' - 0"5' - 0" 6' - 0"7' - 10"1' - 11" 5' - 0"5' - 0" 6' - 0 " 5' - 8 " 4' - 6 " 3' - 1 1 " 2' - 6 " 1' - 3 " 3' - 0 " 1' - 3 " KITCHEN LIVING ROOM LAUNDRY LIVING ROOM LAUNDRY KITCHEN BED ROOM BED ROOM MASTER ROOM BATHROOM BATHROOM BATHROOM CLS. CLS. CLS. NEW LANDSACPE LIVING ROOM BEDROOM BEDROOM BEDROOM BATH ROOM KITCHEN DINNING ROOM PROPOSED JADU 500 SQFT. 22"X30" ATTIC ACCESS 4 1 16 2 14 5 6 7 9 6 13 1 10 20 11 3 5 18 7 15 8 18 9 8 2120 19 13 6" 2" 2" 6" 4' - 0 " 4' - 4" A.1 A.1 A.1 A.1 A.1 22"X30" ATTIC ACCESS A.2 A.2 A.2 A.3 A.3 A.3 A.3 A.1 A.3 EXTERIOR 1 HR. WOOD STUD WALL - SEE 6/D1EXTERIOR 1 HR. WOOD STUD WALL - SEE 6/D1 FIRE RETARDANT BY VIANCE, LLC ICC ESR# 2645FIRE RETARDANT BY VIANCE, LLC ICC ESR# 2645 INTERIOR 1 HR. PARTY WOOD STUD WALL- STC 50 SEE 3/D1INTERIOR 1 HR. PARTY WOOD STUD WALL- STC 50 SEE 3/D1 A.2 INTERIOR 1 HR. WOOD STUD WALL SEE 5/D1INTERIOR 1 HR. WOOD STUD WALL SEE 5/D1 Scale Project number Date Drawn by Checked by Consultant Address Address Phone e-mail Consultant Address Address Phone e-mail fo.studio11@gmail.com Henry M Funes (562) 572-4620 Maria Ornelas Funes (323) 715-1877 10929 S Burin Ave Inglewood, CA. 90304 Ow n e r Consultant Address Address Phone e-mail As indicated 11 / 6 / 2 0 2 4 1 : 2 9 : 2 3 A M A301 2023-015 April 17, 2024 Author Checker 14 0 1 S R o s e w o o d A v e S a n t a A n a , C A 92 7 0 7 Floor Plan He c t o r H e r n a n d e z 75 0 S . F . A D U & 5 0 0 S . F . J A D U No.Description Date 1/4" = 1'-0"1 ADU Level 1 Door Schedule Type Mark Height Width Phase Created Phase Demolished 3 7' - 0"2' - 8"New Construction None 3 7' - 0"2' - 8"Existing New Construction 8 6' - 6"16' - 0"Existing New Construction 3 7' - 0"2' - 8"New Construction None 3 7' - 0"2' - 8"New Construction None 3 7' - 0"2' - 8"New Construction None 9 0' - 0"0' - 0"New Construction None 17 7' - 0"2' - 6"New Construction None 3 7' - 0"2' - 8"New Construction None 3 7' - 0"2' - 8"New Construction None 21 6' - 8"5' - 0"New Construction None 21 6' - 8"5' - 0"New Construction None 9 0' - 0"0' - 0"New Construction None 22 7' - 0"3' - 0"New Construction None 1 7' - 0"3' - 0"New Construction None 17 7' - 0"2' - 6"New Construction None 6 6' - 8"3' - 0"Existing New Construction 6 6' - 8"3' - 0"Existing None 11 0' - 0"0' - 0"Existing None 11 0' - 0"0' - 0"Existing None 11 0' - 0"0' - 0"Existing None 11 0' - 0"0' - 0"Existing None 11 0' - 0"0' - 0"Existing None 11 0' - 0"0' - 0"Existing None 11 0' - 0"0' - 0"Existing None 23 0' - 0"0' - 0"Existing None Window Schedule Mark Height Width Phase Created Phase Demolished 1 5' - 0"4' - 0"New Construction None 2 5' - 0"4' - 0"New Construction None 3 5' - 0"4' - 0"New Construction None 4 5' - 0"4' - 0"New Construction None 5 2' - 0"4' - 0"New Construction None 6 3' - 0"2' - 0"New Construction None 7 5' - 0"4' - 0"New Construction None 8 3' - 0"3' - 0"Existing None 9 4' - 0"3' - 0"Existing None 10 3' - 0"3' - 0"Existing New Construction 11 1' - 0"3' - 0"Existing New Construction 13 4' - 0"5' - 0"Existing None 18 4' - 0"5' - 0"Existing None 19 4' - 0"3' - 0"Existing None 20 4' - 0"3' - 0"Existing None 21 4' - 0"3' - 0"Existing None 22 3' - 0"3' - 0"Existing New Construction NOTES: a. Reinforcement for grab bar installation for bathrooms shall be provided. (R327.1.1) i. At least one bathroom on the entry level shall be provided with reinforcement installed. If there is no bathroom on the entry level, at least one on the second or third floor of the dwelling shall comply. 1. Reinforcement shall be solid lumber or other construction materials approved by the enforcing agency. 2. Reinforcement shall not be less than 2 by 8 inch nominal lumber or other construction material providing equal height and load capacity. 3. Reinforcement shall be located between 32 inches and 39¼ inches above finished floor flush with the wall framing. 4. Water closet reinforcement shall be installed on both side walls of the fixture, or one side wall and the back wall. 5. Shower reinforcement shall be continuous where wall framing is provided. 6. Bathtub and combination bathtub/shower reinforcement shall be continuous on each end of the bathtub and the back wall. Additionally, back wall reinforcement for a lower grab bar shall be provided with the bottom edge located no more than 6 inches above the bathtub rim. b. Electrical receptacle outlets, switches and controls intended to be used by occupants shall be located no more than 48 inches measured from the top of the outlet box and not less than 15 inches measured from the bottom of the outlet box above the finish floor unless exception met. (R327.1.2) c. Interior door width (at least one bedroom door and one bathroom door with 32  clear opening), effective July 1, 2024 (R327.1.3) d. Doorbell buttons or controls, when installed, shall not exceed 48 inches above exterior floor or landing, measured from the top of the doorbell button assembly. Where doorbell height requirement cannot be met for integrated doorbell features, a standard doorbell button or control shall also be provided at a height not exceeding 48 inches above exterior floor or landing, measured from the top of the doorbell button or control. (R327.1.4) 950 E 3rd St. Unit 4104 Los Angeles CA 90013 1401 S Rosewood Ave Unit# 2& 34/22/2025 Ceiling9' - 6" Existing House1' - 6" G.F.0' - 0" 8' - 0 " Ceiling9' - 6" Existing House1' - 6" G.F. 0' - 0" Ceiling9' - 6" Existing House1' - 6" G.F.0' - 0" Ceiling9' - 6" Existing House 1' - 6" G.F.0' - 0" Scale Project number Date Drawn by Checked by Consultant Address Address Phone e-mail Consultant Address Address Phone e-mail fo.studio11@gmail.com Henry M Funes (562) 572-4620 Maria Ornelas Funes (323) 715-1877 10929 S Burin Ave Inglewood, CA. 90304 Ow n e r Consultant Address Address Phone e-mail 1/8" = 1'-0" 9/ 2 4 / 2 0 2 4 1 : 5 6 : 4 6 A M A401 2023-015 April 17, 2024 Author Checker 14 0 1 S R o s e w o o d A v e S a n t a A n a , C A 92 7 0 7 Existing Elevation He c t o r H e r n a n d e z 75 0 S . F . A D U & 5 0 0 S . F . J A D U No.Description Date 1/8" = 1'-0"1 Existing North 1/8" = 1'-0"2 Existing East 1/8" = 1'-0"3 Existing South 1/8" = 1'-0"4 Existing West 950 E 3rd St. Unit 4104 Los Angeles CA 90013 1401 S Rosewood Ave Unit# 2& 34/22/2025 ADU Level 1 0' - 8" Ceiling9' - 6" Existing House1' - 6" G.F. 0' - 0" TO MATCH EXISTING MATERIALS ADU Level 1 0' - 8" Ceiling9' - 6" Existing House 1' - 6"8' - 0 " G.F. 0' - 0" TO MATCH EXISTING MATERIALS 8 UNDER FLOOR VENTS @ S.F.R. ADU Level 1 0' - 8" Ceiling9' - 6" Existing House1' - 6" G.F. 0' - 0" TO MATCH EXISTING MATERIALS 8 UNDER FLOOR VENTS @ S.F.R. ADU Level 1 0' - 8" Ceiling9' - 6" Existing House1' - 6" G.F.0' - 0" 8 UNDER FLOOR VENTS @ S.F.R. ADU Level 10' - 8" Ceiling9' - 6" Existing House1' - 6" G.F.0' - 0" 6 A402 ADU Level 10' - 8" Ceiling9' - 6" Existing House 1' - 6" G.F.0' - 0" 5 A402 Scale Project number Date Drawn by Checked by Consultant Address Address Phone e-mail Consultant Address Address Phone e-mail fo.studio11@gmail.com Henry M Funes (562) 572-4620 Maria Ornelas Funes (323) 715-1877 10929 S Burin Ave Inglewood, CA. 90304 Ow n e r Consultant Address Address Phone e-mail As indicated 12 / 3 1 / 2 0 2 4 5 : 3 6 : 2 1 P M A402 2023-015 April 17, 2024 Author Checker 14 0 1 S R o s e w o o d A v e S a n t a A n a , C A 92 7 0 7 Elevation & Section He c t o r H e r n a n d e z 75 0 S . F . A D U & 5 0 0 S . F . J A D U No.Description Date 1/8" = 1'-0"1 East 1/8" = 1'-0"2 North 1/8" = 1'-0"3 South 1/8" = 1'-0"4 West 1/4" = 1'-0"5 Section 1 1/4" = 1'-0"6 Section 2 UNDERFLOOR VENTS RELOCATION FOR (E) S.F.R.: 1,160 S.F./150 = 7.73 S.F.*144 IN = 1,133.12 S.IN./65 S.IN.= 18 VENTS NOTES: 1.ONE VENTILATION OPENING SHALL BE PLACED WITHIN 3 FEET OF EACH CORNER OF THE BUILDING. 2.THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1 /150 OF THE CRAWL SPACE AREA. 3.OPENINGS SHALL HAVE CORROSION-RESISTANT WIRE MESH OR OTHER APPROVED MATERIAL WITH 1/8 IN MINIMUM AND 1 /4 IN. MAXIMUM OPENING.. 1401 S Rosewood Ave Unit# 2& 34/22/2025 Scale Project number Date Drawn by Checked by Consultant Address Address Phone e-mail Consultant Address Address Phone e-mail fo.studio11@gmail.com Henry M Funes (562) 572-4620 Maria Ornelas Funes (323) 715-1877 10929 S Burin Ave Inglewood, CA. 90304 Ow n e r Consultant Address Address Phone e-mail 3/16" = 1'-0" 9/ 2 4 / 2 0 2 4 1 : 5 6 : 5 1 A M A501 2023-015 April 17, 2024 Author Checker 14 0 1 S R o s e w o o d A v e S a n t a A n a , C A 92 7 0 7 Existing Roof Plan He c t o r H e r n a n d e z 75 0 S . F . A D U & 5 0 0 S . F . J A D U No.Description Date 3/16" = 1'-0"1 Existing Roof Plan 950 E 3rd St. Unit 4104 Los Angeles CA 90013 1401 S Rosewood Ave Unit# 2& 34/22/2025 4" / 1'-0" 4" / 1 ' - 0 " 4" / 1 ' - 0 " 4" / 1 ' - 0 " 4" / 1 ' - 0 " 4" / 1'-0" 4" / 1 ' - 0 " 4" / 1'-0"4" / 1'-0" 4" / 1'-0" Scale Project number Date Drawn by Checked by Consultant Address Address Phone e-mail Consultant Address Address Phone e-mail fo.studio11@gmail.com Henry M Funes (562) 572-4620 Maria Ornelas Funes (323) 715-1877 10929 S Burin Ave Inglewood, CA. 90304 Ow n e r Consultant Address Address Phone e-mail 3/16" = 1'-0" 11 / 6 / 2 0 2 4 2 : 2 0 : 5 1 A M A502 2023-015 April 17, 2024 Author Checker 14 0 1 S R o s e w o o d A v e S a n t a A n a , C A 92 7 0 7 Roof Plan He c t o r H e r n a n d e z 75 0 S . F . A D U & 5 0 0 S . F . J A D U No.Description Date 3/16" = 1'-0"1 Roof Plan (NEW) CLASS 'A' COMP ICC Evaluation Report ESR-1389 Code: 0668-0055 SEE DETAIL (RT) on PAGE : D1 SHINGLES OVER 13 PAPER ICC Evaluation Report ESR-1389 Code: 0668-0055 - CertainTeed Corporation: CertainTeed Landmark Solaris AGED CEDAR Steep Slope: Asphalt Shingles Orange, Grey, Brown, Multicolor SRI VALUE 28 / 3 YR SOLAR REFLECTANCE 0.27 THERMAL EMMITANCE 0.89 ICC Evaluation Report ESR-1389 ASTM D3018 Type I, ASTM D3462 ASTM E108 Fire Resistance: Class A ASTM D3161 Class F Wind Resistance ASTM D7158 Class H Wind Resistance UL 2390/ASTM D6381 Class H Wind Resistance UL 790 Fire Resistance: Class A UL 997 Wind Resistance, NYC-MEA-120-79-M CSA Standard A123.5-98 (& -05) Ontario BMEC Auth. 97-10-219 Miami-Dade Product Control Approved Florida Product Approval # FL5444 Energy Star Rated CA Title 24, Part 6 (Cool Steep Slope Roofing) USGBC LEED®-NC JADU ATTIC VENTILATION NFA VENT (SQ.IN.) UNITS TOTAL NFAVENTSTYPESYMBOL UNDER EAVE 14"x5"INTAKE 65 4 260 18" ROOF VENTILATOR- SEE SPEC 254 1 254EXHAUST ATTIC VENTILATION CALC.ATTIC VENTILATION CALC. THE MINIMUM NET FREE AREA VENTILATION SHALL BE 1/150 OF THE AREA OF VENTED SPACE. AREA ATTIC =500 SQ.FT. ATTIC VENTILATION REQUIRED NET FREE AREA = 500 SQ.FT. / 150.00 =3.3 SQ.FT. =3.3 SQ.FT. X 144 SQ. IN. TOTAL VENTILATION=475.2 =475.2X.5 =237.6 EXHAUST NET FREE REQUIRED 50% TOTAL NET FREE AREA =237.6 SQ. IN. INTAKE NET FREE REQUIRED 50% TOTAL NET FREE AREA =237.6 SQ. IN. 1. 2. 3. NOTES THE NET FREE VENTILATING AREA OF ENCLOSED ATTIC & ENCLOSED RAFTER SPACES SHALL NOT BE LESS THAN 1 150 OF THE SPACE VENTILATED AND SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE. PROVIDE A MINIMUM OF 1" AIR SPACE BETWEEN INSULATIONS AND THE ROOF SHEATHING. REPALCE ALL DEMO VENTS OF THE EXISTING ROOF TO BE ADDED TO TOTAL OF NEW VENTS EXHAUST REQUIRED = 237.6 AND PROVIDED EXHAUST =254 INTAKE REQUIRED = 237.6 AND PROVIDED INTAKE =260 TOTAL VENTILATION=475.3 AND PROVIDED VENTILATION = 514 ADU ATTIC VENTILATION NFA VENT (SQ.IN.) UNITS TOTAL NFAVENTSTYPESYMBOL UNDER EAVE 14"x5"INTAKE 65 6 390 18" ROOF VENTILATOR- SEE SPEC 254 2 508EXHAUST ATTIC VENTILATION CALC.ATTIC VENTILATION CALC. THE MINIMUM NET FREE AREA VENTILATION SHALL BE 1/150 OF THE AREA OF VENTED SPACE. AREA ATTIC =750 SQ.FT. ATTIC VENTILATION REQUIRED NET FREE AREA = 750 SQ.FT. / 150.00 =5 SQ.FT. =5 SQ.FT. X 144 SQ. IN. TOTAL VENTILATION=720 =720X.5 =360 EXHAUST NET FREE REQUIRED 50% TOTAL NET FREE AREA =360 SQ. IN. INTAKE NET FREE REQUIRED 50% TOTAL NET FREE AREA =360 SQ. IN. 1. 2. 3. NOTES THE NET FREE VENTILATING AREA OF ENCLOSED ATTIC & ENCLOSED RAFTER SPACES SHALL NOT BE LESS THAN 1 150 OF THE SPACE VENTILATED AND SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE. PROVIDE A MINIMUM OF 1" AIR SPACE BETWEEN INSULATIONS AND THE ROOF SHEATHING. REPALCE ALL DEMO VENTS OF THE EXISTING ROOF TO BE ADDED TO TOTAL OF NEW VENTS EXHAUST REQUIRED = 360 AND PROVIDED EXHAUST =508 INTAKE REQUIRED = 360 AND PROVIDED INTAKE =390 TOTAL VENTILATION=720 AND PROVIDED VENTILATION = 898 USE THIS CALCULATIONS TO COMPLITE THE EXHAUST VENTS FOR THE EXISTING HOUSE IF ANY VENTS ARE TAKED OUT DUE TO THE ADITION EXISTING HOME ATTIC VENTILATION NFA VENT (SQ.IN.) UNITS TOTAL NFAVENTSTYPESYMBOL UNDER EAVE 14"x5"INTAKE 65 9 585 18" ROOF VENTILATOR- SEE SPEC 254 3 762EXHAUST ATTIC VENTILATION CALC.ATTIC VENTILATION CALC. THE MINIMUM NET FREE AREA VENTILATION SHALL BE 1/150 OF THE AREA OF VENTED SPACE. AREA ATTIC =1160 SQ.FT. ATTIC VENTILATION REQUIRED NET FREE AREA = 1160 SQ.FT. / 150.00 =7.73 SQ.FT. =7.73 SQ.FT. X 144 SQ. IN. TOTAL VENTILATION=1113.12 =1113.12X.5 =556.56 EXHAUST NET FREE REQUIRED 50% TOTAL NET FREE AREA =556.56 SQ. IN. INTAKE NET FREE REQUIRED 50% TOTAL NET FREE AREA =556.56 SQ. IN. 1. 2. 3. NOTES THE NET FREE VENTILATING AREA OF ENCLOSED ATTIC & ENCLOSED RAFTER SPACES SHALL NOT BE LESS THAN 1 150 OF THE SPACE VENTILATED AND SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE. PROVIDE A MINIMUM OF 1" AIR SPACE BETWEEN INSULATIONS AND THE ROOF SHEATHING. REPALCE ALL DEMO VENTS OF THE EXISTING ROOF TO BE ADDED TO TOTAL OF NEW VENTS EXHAUST REQUIRED = 556.56 AND PROVIDED EXHAUST =762 INTAKE REQUIRED = 556.56 AND PROVIDED INTAKE =750 TOTAL VENTILATION=1113.12 AND PROVIDED VENTILATION = 1347 USE THIS CALCULATIONS TO COMPLITE THE EXHAUST VENTS FOR THE EXISTING HOUSE IF ANY VENTS ARE TAKED OUT DUE TO THE ADITION UNDER EAVE VENT #1 JADU UNDER EAVE VENT #2 JADU UNDER EAVE VENT #3 JADUUNDER EAVE VENT #4 JADU UNDER EAVE VENT #1 ADU UNDER EAVE VENT #2 ADU UNDER EAVE VENT #3 ADU UNDER EAVE VENT #4 ADU UNDER EAVE VENT #6 ADU UNDER EAVE VENT #5 ADU UNDER EAVE VENT #1 HOUSE UNDER EAVE VENT #2 HOUSE UNDER EAVE VENT #3 HOUSE UNDER EAVE VENT #4 HOUSE UNDER EAVE VENT #5 HOUSE UNDER EAVE VENT #6 HOUSE UNDER EAVE VENT #7 HOUSE UNDER EAVE VENT #8 HOUSE UNDER EAVE VENT #9 HOUSE 950 E 3rd St. Unit 4104 Los Angeles CA 90013 1401 S Rosewood Ave Unit# 2& 34/22/2025 D-1 Scale Project number Date Drawn by Checked by Consultant Address Address Phone e-mail Consultant Address Address Phone e-mail 2023- 015 October 17, 2023 H.M.F. & M.O. N/A 14 0 1 S R o s e w o o d A v e . Sa n t a A n a , C A 9 2 7 0 7 fo.studio11@gmail.com Henry M Funes (562) 572-4620 Maria Ornelas Funes (323) 715-1877 10929 S Burin Ave Inglewood, CA. 90304 No.Description Date Architectural Details He c t o r H e r n a n d e z Ow n e r Consultant Address Address Phone e-mail 50 0 S . F . J A D U U N I T # 2 & 7 5 0 A D U U N I T # 3 950 E 3rd St. Unit 4104 Los Angeles CA 90013 1401 S Rosewood Ave Unit# 2& 34/22/2025 1234 5678 91012 DOOR JAMB HOLLOW METAL 2 x FRAMING HEADER. FLASHING STRIPS FOR NAIL ON FRAMES PLASTER @ CORNER TYPICAL WEEP SCREED SLAB DEPRESSION FLASHING @ DECK STEP 1. ATTACH SILL STRIPS WITH SILL AND EXTEND OUT BEYOND OPENING STEP 2. ATTACH JAMB STRIPS EVEN OPENING SIDE AND EXTEND ABOVE AND BELLOW SILL STIP. STEP 3. PLACE WINDOW INTO OPENING WITH NAILED FLANGES OVER AND SEALED STEP 4. INSTALL UNDERLAYMENT BEGINNING AT THE BOTTOM WITH LAYER 1 SO IT LAYS BENEATH THE SILL STRIP ANDTO THE SEAL AND JAMB STRIPS WITH A COMPATIBLE SEALANT THEN INSTALL HEAD STRIP. CONTINUING WITH ADDITIONAL OVERLAPPING LAYERS UP THE WALL OVER THE JAMB AND THE HEAD STRIPS. DRIP FRAME ON SHEETING EXT. PLASTER WHERE OCCURS BATT. INSULATION METAL FLASHING STRIP HOLLOW METAL 2 x FRAMING HEADER. ON 2 x FRAMING BATT. INSULATION SEALANT FRAME 5 8" TYPE 'X' GYPSUM BOARD EXTERIOR CEMENT PLASTERON LATH METAL CORNER BEADVAR I E S 5 8" TYPE 'X' GYPSUM BOARD 2 x FRAMING STUDS & LATH ON SHEETING EXT. PLASTER BASE & FLOORING R = 13 BATT. INSULATION PER SCHEDULE CONCRETE SLAB & FOOTING PER STRUCTURAL WEEP SCREED CONCRETE SLAB ON GRADE WATERPROOF MEMBRANE & PROTECTION BD. ON RET. WALL CONT. SHEET METAL FLASHING INTEGRAL WITH DRIP SCREED MORTAR SETTING BED SLOPE 1/4":12" PAVER PER LANDSCAPE BATT. INSULATION 24 GA. WEEP SCREED TYPICAL EXTERIOR WALL CONSTRUCTION FLOOR LINE WATERPROOF DECKING REINFORCING MESH MIN. 28 GA. BONDERIZED FLASHING EXTERIOR PLASTER ON MET. LATH WALL LINE EXT. PLASTER WHERE OCCURS BATT. INSULATION 5 8" W.R. TYPE 'X' GYPSUM BOARD 1/2" CEMENT 2 x FRAMING STUDS CALKING TILES JAMB & HEAD @ WALL 3 SLIDING WINDOW HEAD & SILL EXT. PLASTER ON SHEATING WATER RESISTANT BARRIER WITH MTL. EDGE 5 8" TYPE 'X' GYPSUM BOARD RECESSED WATER RESISTANT BARRIER BATT. INSULATION STUDS 2 x FRAMING WHERE OCCURS EXT. PLASTER ON SHEATING WHERE OCCURS EXTERIOR SIDEINTERIOR SIDE STUCCO FINISH TO MATCH EXTERIOR D-2 Scale Project number Date Drawn by Checked by Consultant Address Address Phone e-mail Consultant Address Address Phone e-mail 2023- 015 October 17, 2023 H.M.F. & M.O. N/A 14 0 1 S R o s e w o o d A v e . Sa n t a A n a , C A 9 2 7 0 7 fo.studio11@gmail.com Henry M Funes (562) 572-4620 Maria Ornelas Funes (323) 715-1877 10929 S Burin Ave Inglewood, CA. 90304 No.Description Date Architectural Details He c t o r H e r n a n d e z Ow n e r Consultant Address Address Phone e-mail 50 0 S . F . J A D U U N I T # 2 & 7 5 0 A D U U N I T # 3 950 E 3rd St. Unit 4104 Los Angeles CA 90013 1401 S Rosewood Ave Unit# 2& 34/22/2025 STRUCTURAL NOTES ALL TYPICAL DETAILS. CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. ENGINEER: Margarito Castillo, S.E. MARK DATE REVISIONS STRUCTURAL NOTES: JOB NO: DRAWN: CHECKED: DATE: ARCHITECT: 468 N Camden Dr # 200, Beverly Hills, CA 90210 (310) 658-1225 estructuramx PROJECT : 1401 S ROSEWOOD AVE PROJECT ADDRESS: 1401 S ROSEWOOD AVE SANTA ANA, CALIFORNIA 92707 SHEET NO.: SHEET TITLE: 24-088 DC MC 12 APRIL 24 hello@emxse.com emxse.com 09/09/24 PLAN CHECK S1.0 GENERAL NOTES 1401 S Rosewood Ave Unit# 2& 34/22/2025 I II III IV VIIIVIIVIV XIIXIXIX ALL TYPICAL DETAILS. CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. ENGINEER: Margarito Castillo, S.E. MARK DATE REVISIONS STRUCTURAL NOTES: JOB NO: DRAWN: CHECKED: DATE: ARCHITECT: 468 N Camden Dr # 200, Beverly Hills, CA 90210 (310) 658-1225 estructuramx PROJECT : 1401 S ROSEWOOD AVE PROJECT ADDRESS: 1401 S ROSEWOOD AVE SANTA ANA, CALIFORNIA 92707 SHEET NO.: SHEET TITLE: 24-088 DC MC 12 APRIL 24 hello@emxse.com emxse.com 09/09/24 PLAN CHECK S1.1 1401 S Rosewood Ave Unit# 2& 34/22/2025 .I II VIVIII VI VII VIII ALL TYPICAL DETAILS CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. ENGINEER: Margarito Castillo, S.E. MARK DATE REVISIONS STRUCTURAL NOTES: JOB NO: DRAWN: CHECKED: DATE: ARCHITECT: 468 N Camden Dr # 200, Beverly Hills, CA 90210 (310) 658-1225 estructuramx PROJECT : 1401 S ROSEWOOD AVE PROJECT ADDRESS: 1401 S ROSEWOOD AVE SANTA ANA, CALIFORNIA 92707 SHEET NO.: SHEET TITLE: 24-088 DC MC 12 APRIL 24 hello@emxse.com emxse.com 09/09/24 PLAN CHECK S1.2 ALL TYPICAL DETAILS 1401 S Rosewood Ave Unit# 2& 34/22/2025 I II III IV VIIIVIIVIV ALL TYPICAL DETAILS CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. ENGINEER: Margarito Castillo, S.E. MARK DATE REVISIONS STRUCTURAL NOTES: JOB NO: DRAWN: CHECKED: DATE: ARCHITECT: 468 N Camden Dr # 200, Beverly Hills, CA 90210 (310) 658-1225 estructuramx PROJECT : 1401 S ROSEWOOD AVE PROJECT ADDRESS: 1401 S ROSEWOOD AVE SANTA ANA, CALIFORNIA 92707 SHEET NO.: SHEET TITLE: 24-088 DC MC 12 APRIL 24 hello@emxse.com emxse.com 09/09/24 PLAN CHECK S1.3 ALL TYPICAL DETAILS 1401 S Rosewood Ave Unit# 2& 34/22/2025 SCALE: = 1'-0"I FOUNDATION PLAN 1/4" N ALL TYPICAL DETAILS CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. ENGINEER: Margarito Castillo, S.E. MARK DATE REVISIONS STRUCTURAL NOTES: JOB NO: DRAWN: CHECKED: DATE: ARCHITECT: 468 N Camden Dr # 200, Beverly Hills, CA 90210 (310) 658-1225 estructuramx PROJECT : 1401 S ROSEWOOD AVE PROJECT ADDRESS: 1401 S ROSEWOOD AVE SANTA ANA, CALIFORNIA 92707 SHEET NO.: SHEET TITLE: 24-088 DC MC 12 APRIL 24 hello@emxse.com emxse.com 09/09/24 PLAN CHECK S2.0 FOUNDATION PLAN 1401 S Rosewood Ave Unit# 2& 34/22/2025 .SCALE: = 1'-0"2 ROOF FRAMING PLAN 1/4" N C. J . ALL TYPICAL DETAILS CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. ENGINEER: Margarito Castillo, S.E. MARK DATE REVISIONS STRUCTURAL NOTES: JOB NO: DRAWN: CHECKED: DATE: ARCHITECT: 468 N Camden Dr # 200, Beverly Hills, CA 90210 (310) 658-1225 estructuramx PROJECT : 1401 S ROSEWOOD AVE PROJECT ADDRESS: 1401 S ROSEWOOD AVE SANTA ANA, CALIFORNIA 92707 SHEET NO.: SHEET TITLE: 24-088 DC MC 12 APRIL 24 hello@emxse.com emxse.com 09/09/24 PLAN CHECK S2.2 ROOF PLAN 1401 S Rosewood Ave Unit# 2& 34/22/2025 .I II III IV VIIIVIIVIV XIIXIXIX X ALL TYPICAL DETAILS CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. ENGINEER: Margarito Castillo, S.E. MARK DATE REVISIONS STRUCTURAL NOTES: JOB NO: DRAWN: CHECKED: DATE: ARCHITECT: 468 N Camden Dr # 200, Beverly Hills, CA 90210 (310) 658-1225 estructuramx PROJECT : 1401 S ROSEWOOD AVE PROJECT ADDRESS: 1401 S ROSEWOOD AVE SANTA ANA, CALIFORNIA 92707 SHEET NO.: SHEET TITLE: 24-088 DC MC 12 APRIL 24 hello@emxse.com emxse.com 09/09/24 PLAN CHECK S3.0 FOUNDATION AND ROOF DETAILS 1401 S Rosewood Ave Unit# 2& 34/22/2025 X X X X X X X X X X X X X X X X X X X X X X X D E S I G N E R CONT. CONT. CONT. CONT. CONT. CONT. CONT. CONT. CONT. CONT. CONT. CONT. OWNER . 1401 S Rosewood Ave Unit# 2& 34/22/2025 X X X X X X X X X X X X X X X X X X X X X X X X X CONT. CONT. CONT. CONT. CONT. CONT. CONT. CONT.CONT. CONT. CONT. CONT. CONT. CONT. CONT. CONT. CONT. CONT. CONT. CONT. CONT. CONT. CONT. . 1401 S Rosewood Ave Unit# 2& 34/22/2025 REVISIONS BY 3 . 1401 S Rosewood Ave Unit# 2& 34/22/2025 REVISIONS BY . . 1401 S Rosewood Ave Unit# 2& 34/22/2025 REVISIONS BY . . 1401 S Rosewood Ave Unit# 2& 34/22/2025 REVISIONS BY . 3 . 1401 S Rosewood Ave Unit# 2& 34/22/2025 REVISIONS BY . . 1401 S Rosewood Ave Unit# 2& 34/22/2025 REVISIONS BY . . 1401 S Rosewood Ave Unit# 2& 34/22/2025 E CMSD SD CM A-WALL FURNACE HEATER, WALL CABINET MOUNTED, 25,000 BTU UP TO 1000 SQ. FT. HOME. B-WALL FURNACE HEATER, WALL CABINET MOUNTED, 35,000 BTU UP TO 1200 SQ. FT. HOME. C-WALL FURNACE HEATER, WALL CABINET MOUNTED, 50,000 BTU UP TO 1500 SQ. FT. HOME. 5.6 GPM A-THANKLESS WATER HEATER 9.5 GPM, 199,900 BTU NAT. GAS, FOR 3 BATHROOM HOMES. B-THANKLESS WATER HEATER 8.4 GPM, 157,000 BTU NAT. GAS, FOR 2-3 BATHROOM HOMES. C-THANKLESS WATER HEATER 5.6 GPM, 150,000 BTU NAT. GAS, FOR 1-2 BATHROOM HOMES. 25000 BTU A- EXHAUST FAN 50-70 CFM, UP TO 70 SQ. FT.; VENTED TO OUTSIDE AIR B- EXHAUST FAN 70-100 CFM, UP TO 100 SQ. FT.; VENTED TO OUTSIDE AIR C- EXHAUST FAN 100 CFM UP, 100 SQ. FT.; UP; VENTED TO OUTSIDE AIR 50 CFM 1. 2. 3. 4. 5. LIGHTING MEASURES: (150.0(k)) KITCHENS. ALL INSTALLED WATTAGE OF LUMINARIES IN KITCHENS SHALL BE HIGH EFFICACY. LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOM, AND UTILITY ROOM. ALL LUMINARIES SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY A VACANCY SENSOR. OTHER ROOMS. ALL LUMINARIES SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY A VACANCY SENSOR OR DIMMER. CLOSETS THAT ARE LESS THAN 70 S.F. ARE EXEMPT FROM THIS REQUIREMENT. OUTDOOR LIGHTING. ALL LUMINARIES MOUNTED TO THE BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINARIES AND SHALL BE CONTROLLED BY A PHOTOCONTROL/ MOTION SENSOR COMBINATION (WITH OVERRIDE). SEE 150(k)3 FOR REQUIREMENTS. COUNTERTOPS IN THE KITCHEN, DINING AREA, AND SIMILAR AREAS REQUIRE A RECEPTACLE TO BE PROVIDED FOR EACH COUNTER SPACE WIDER THAN 12 INCHES SO THAT NO POINT IS MORE THAN 24" FROM AN OUTLET (CEC 210.52(C) FOR NEW INSTALLED WATER HEATER: 1. PROVIDE A DEDICATED 125V 20A (10AWG COPPER BRANCH CIRCUIT) ELECTRICAL RECEPTACLE THAT IS WITHIN 3 FT. FROM THE WATER HEATER AND ACCESSIBLE TO THE WATER HEATER WITH NO OBSTRUCTIONS. THERE SHALL BE A RESERVED SINGLE POLE BREAKER SPACE IN THE ELECTRICAL PANEL LABELED "FUTURE 240V USE". 2. A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE BETWEEN THE OUTSIDE TERMINATION AND THE SPACE WHERE THE WATER HEATER IS INSTALLED. 3. A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF THE INSTALLED WATER HEATER, AND ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE. 4. A GAS SUPPLY LINE WITH A CAPACITY OF AT LEAST 200,000 BTU/HR. REQUIRED SIZE: 3/4 MINIMIM SIZE FOR THE LINE NOTE: EXHAUST FANS IN BATHROOMS SHALL COMPLY WITH THE FOLLOWING: A. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING. B. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, THE FAN MUST BE CONTROLLED BY A HUMIDITY CONTROL. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50 TO 80%. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO AN EXHAUST FAN AND IS NOT REQUIRED TO BE INTEGRAL. SYMBOL ELECTRICAL SCHEDULE SPECIAL NOTES 1. 2. 3. 4. 5. CARBON MONOXIDE AND SMOKE ALARMS ARE REQUIRED FOR ALTERATIONS, REPAIRS OR ADDITIONS WHERE A PERMIT VALUATION EXCEEDS $1,000 (R314 & R315) CARBON MONOXIDE ALARMS SHALL BE PROVIDED IN EXISTING DWELLINGS OR SLEEPING UNITS THAN HAVE ATTACHED GARAGES OR FUEL BURNING APPLIANCES, LOCATE SUCH ALARMS OUTSIDE OF EACH SEPARATE DOWELING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS SMOKE ALARMS SHALL BE INSTALLED IN EACH SLEEPING ROOM AND OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. NEW CONSTRUCTIONS 120 VOLT WITH BATTERY BACKUP OPERATED AND INTERCONNECTED. EXISTING CONSTRUCTION BATTERY OPERATED COMBINATION TYPE ARC FAULT CIRCUIT INTERRUPTERS (AFCI) SHALL BE INSTALLED IN ALL DWELLING UNIT FAMILY ROOMS, LIVING ROOMS, BEDROOMS, CLOSET, HALLWAY AND SIMILAR ROOMS/AREAS ALL REQUIRED 15 20 AMPERE RECEPTACLES LISTED IN SECTION 210.52 FOR DWELLING UNITS SHALL BE LISTED TAMPER RESISTANT RECEPTACLES TR/GFI DUPLEX OUTLET TAMPER RESISTANT W/ARC FAULT PROTECTION LEGEND DUPLEX OUTLET GROUND FAULT INTERRUPTER 3 2 SINGLE SWITCH DUPLEX SINGLE SWITCH TRIPLEX SINGLE SWITCH TR/GFI DUPLEX OUTLET GROUND FAULT INTERRUPTER W/WATERPROOFWP DUPLEX SINGLE OUTLET, TEMPER RESISTANT TR/AFP FL LIGHT, CEILING MOUNTED LIGHT, WALL MOUNTED FLUORESCENT LIGHT, CEILING MOUNTED ELECTRICAL PANEL FL FLUORESCENT RECESSED LIGHT, EXTERIOR WALL MOUNTED EXHAUST FAN 50 CFM,AND FLUORESCENT LIGHT COMBOFL SMOKE ALARM DETECTOR CARBON MONOXIDE ALARM DETECTOR CARBON MONOXIDE AND SMOKE ALARM DETECTOR COMBO EM TR FL FLUORESCENT RECESSED LIGHT, CEILING MOUNTED MS MOTION SENSOR SWITCH 5. 6 G P M TA N K L E S S WA T E R HE A T E R HO T WA T ER 5. 6 G P M TA N K L E S S WA T E R HE A T E R HO T WA T ER (N) 3" AVP PIPE CONNECTING TO SEWER FOR A.D.U. IN FRONT OF HOUSE(verify location on site) se we r se we r se we r se we r se we r se we r (N) 3" AVP PIPE CONNECTING TO SEWER FOR J.A.D.U. IN FRONT OF HOUSE (verify location on site) se we r se we r se we r CONNECTION TO EXISTING WATER LINE, VERIFY EXACT LOCATION ON SITE COL D WAT ER COL D WAT ER HO T WA T ER CO L D WA T ER HO T WA T ER CO L D WA T ER SD CM TR NEW CONDENSER ONTOP OF A CONCRETE PAD W/220- VOLT DISCONNEC T BOX TR TRTR TR SD SD SD SD CM MI N I SP L I T MI N I SP L I T MI N I SP L I T MINI SPLIT MI N I SP L I T TR/GFI NEW CONDENSER ONTOP OF A CONCRETE PAD W/220- VOLT DISCONNEC T BOX 280 CFM TR/GFI TR/GFI TR/GFITR/GFI TR/GFITR/GFI TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR/GFI TR/GFI TR/GFI TR/GFI FL FL FL TR TR TR TR TR TR TR TR TR TR/GFITR/GFI 70 CFM 70 CFM 70 CFM 280 CFM Scale Project number Date Drawn by Checked by Consultant Address Address Phone e-mail Consultant Address Address Phone e-mail fo.studio11@gmail.com Henry M Funes (562) 572-4620 Maria Ornelas Funes (323) 715-1877 10929 S Burin Ave Inglewood, CA. 90304 Ow n e r Consultant Address Address Phone e-mail As indicated 11 / 6 / 2 0 2 4 2 : 2 3 : 2 2 A M MEP-1 2023-015 April 17, 2024 Author Checker 14 0 1 S R o s e w o o d A v e S a n t a A n a , C A 92 7 0 7 MEP PLAN He c t o r H e r n a n d e z 75 0 S . F . A D U & 5 0 0 S . F . J A D U No.Description Date PLUMBING LEGENDHOT WATER PIPE, 3_ 4"COP PER COLD WATER PIPE, COP PER GAS LINE 3_ 4" SEWER LINE 3" AVP POTABLE WATER CONNECTION HOSE BIB, MUST HAVE AN APPROVED ANTI-SIPHON DEVICE H B HW 3_ 4" IR ON HW CW CW CW ELECTRICAL CONDUIT & CONDUCTOR: PROVIDE UP TO 100 FT OF COPPER 3 / 0 AWG IN A 2.5 INCH 80 PVC CONDUIT VENTS, TRAPS, & CLEANOUTSSIZES FOR SINKS & TOILETS: 1.5 INCH TRAP 2 INCH VENT 4 INCH CLEANOUT 1/4" = 1'-0"1 ADU Level 1 MEP 1/4" = 1'-0"2 ADU Level 1 LIGHTING NOTES: 1.Water Heating system (water heater)   (Section 150.0(n)) A.Systems using gas or propane water heaters to serve individual dwelling units shall designate a space at least 2.5 feet by 2.5 feet wide and 7 feet tall suitable for the future installation of a heat pump water heater (HPWH) by meeting either A or B listed under Section 150.0(n). i.If the designated space is within 3 feet from the water heater: a.A dedicated 125 volt, 20 amp electrical receptacle that is connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG copper branch circuit, within 3 feet from the water heater. ii. Isolate both ends of the unused conductor. b.A reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker c.A condensate drain that allows natural draining of the water heater. d.. If the designated space is more than 3 feet from the water heater: see additional Code requirements. B.When a second water heater is installed as part of the addition shall comply with Section (150.2(a)(D). Energy Storage System (ESS) Ready: All single-family residences that include one or two dwelling units, and ADU shall meet the following: a.At least one of the following shall be provided: i.ESS ready interconnection equipment [auto transfer switch and panel] with a minimum backed-up capacity of 60 amps and a minimum of four ESS-supplied branch circuits, or ii.A dedicated, minimum 1  raceway from the main service to a subpanel that supplies the branch circuits in Section 150.0(s)(2). b.A minimum of four branch circuits shall be supplied by the ESS: the refrigerator, one lighting circuit shall be located near the primary egress, and at least one circuit shall supply a sleeping room receptacle outlet. c.The main panelboard shall have a minimum busbar rating of 225 amperes with space to install future isolation equip 1401 S Rosewood Ave Unit# 2& 34/22/2025 5. 6 G P M TA N K L E S S WA T E R HE A T E R HO T WA T E R 5. 6 G P M TA N K L E S S WA T E R HE A T E R HO T WA T ER (N) 3" AVP PIPE CONNECTING TO SEWER FOR A.D.U. IN FRONT OF HOUSE(verify location on site) se we r se we r sewer sewer sewer sewer (N) 3" AVP PIPE CONNECTING TO SEWER FOR J.A.D.U. IN FRONT OF HOUSE (verify location on site) sewer sewer sewer CONNECTION TO EXISTING WATER LINE, VERIFY EXACT LOCATION ON SITE COL D WAT ER COLD WATER HO T W A T E R CO L D W A T E R HO T W A T E R CO L D WA T E R Scale Project number Date Drawn by Checked by Consultant Address Address Phone e-mail Consultant Address Address Phone e-mail fo.studio11@gmail.com Henry M Funes (562) 572-4620 Maria Ornelas Funes (323) 715-1877 10929 S Burin Ave Inglewood, CA. 90304 Ow n e r Consultant Address Address Phone e-mail 1/4" = 1'-0" 11 / 6 / 2 0 2 4 3 : 0 1 : 3 8 A M MEP-2 2023-015 April 17, 2024 Author Checker 14 0 1 S R o s e w o o d A v e S a n t a A n a , C A 92 7 0 7 WATER FIXTURE CALCS He c t o r H e r n a n d e z 75 0 S . F . A D U & 5 0 0 S . F . J A D U PLUMBING LEGEND HOT WATER PIPE, 3_ 4"COPPER COLD WATER PIPE, COPPER GAS LINE 3_ 4" SEWER LINE 3" AVP POTABLE WATER CONNECTION HOSE BIB, MUST HAVE AN APPROVED ANTI-SIPHON DEVICE H B HW 3_ 4" IRON HW CW CW CW VENTS, TRAPS, & CLEANOUTS SIZES FOR SINKS & TOILETS: 1.5 INCH TRAP 2 INCH VENT 4 INCH CLEANOUT 1/4" = 1'-0"1 ADU Level 1 MEP Copy 1 No.Description Date FIXTURE WATER FIXTURE UNIT CALCULATIONS PER TABLE 610.3 CPC FOR EXISTING SINGLE FAMILY HOME, ADU, & JADU SPECIAL NOTES 1.NO PLUMBING FIXTURES WILL BE RELOCATED VALUE TOTAL WATER CLOSET QUANTITY LAVATORY BATHTUB SHOWER HEAD KITCHEN SINK DISHWASHER WASHING MACHINE OUTDOOR HOSE BIB 4 4 3 4 3 3 2 2 2.5 1 4 2 1.5 1.5 4 2.5 10 4 12 8 4.5 4.5 8 5 56 AVAILABLE WATER PRESSURE PIPE SIZING PER TABLE 610.4 PRESSURE LOSS DUE TO BLDG. HEIGHT 45 PSI MIN. WATER PRESSURE FOR REMOTE FIXTURE PRESSURE LOSS THROUGH WATER METER PRESSURE LOSS THROUGH BACKFLOW PREVENTER 10 FT * 0.433= 4.33 PSI 8 PSI 8 PSI 2 PSI TOTAL PRESSURE LOSS 22.33 PSI PRESSURE AVAILABLE FOR FRICTION LOSS 45 PSI- 22.33 PSI= 22.67 DISTANCE TO MOST REMOTE FIXTURE 75 FT * 1.5= 112.5 FT 25TOTAL 1401 S Rosewood Ave Unit# 2& 34/22/2025 Structural Calculations for 1401 S ROSEWOOD AVE REMODEL 1401 S ROSEWOOD SANTA ANA SANTA ANA, CALIFORNIA 92707 10-Apr-24 JOB NO. : 24-088 4 6 8 N O R T H C A M D E N D R I V E 1 3 1 E , B E V E R L Y H I L L S , C A L I F O R N I A 9 0 2 1 0 T : 3 1 0 . 6 5 8 . 1 2 2 5 W W W . E S T R U C T U R A U S A . C O M 1401 S Rosewood Ave Unit# 2& 34/22/2025 DESIGN CRITERIA 1 Soil supporting footings is natural grade or engineered fill. 2 Soil allowable bearing pressure used in design_______________________________ 3 Footing shall extend_____ minimum into undisturbed soil or_____ below finish grade whichever is lower. 4 All concrete shall develop a minimum compressive strength of 2500 psi in 28 days. 5 Reinforcing steel shall conform to ASTM 615, Grade 60. 6 Structural steel shall conform to the following: Wide flange shapes ASTM A992 TS shapes ASTM A500, Grade B Pipe shapes ASTM A53 , Grade B Other rolled shapes, Bars and plates ASTM A36 7 Structural steel shall be fabricated in a shop of an approved fabricator. 8 All welding shall be done by Certified Welders. 9 Concrete Block shall conform to ASTM C90, Grade N-1. 10 Grout shall develop 2000 psi in 28 days. 11 Mortar shall be Type S and develop 1800 psi in 28 days. 12 All lumber shall be grade marked Douglas Fir. (Grading rule No. 17) Light Framing Construction Joist & Planks No. 2 Beams & Stringers No. 1 Posts & Timbers No. 1 13 Glue Laminated Timbers shall be combination No. 24F-V8. 14 Plywood shall conform to PS 1-95, Structural 1. 15 All material and workmanship shall conform to the requirements of 2022 California Building Code. ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 Fb Ft Fc perp.Fc Fv E E min CONSTRUCTION 1000 650 625 1650 180 1,500,000 550,000 NO. 2 900 575 625 1350 180 1,600,000 580,000 NO. 1 1200 825 625 1000 170 1,600,000 580,000 NO. 1 1350 675 625 925 170 1,600,000 580,000 COMBINATION 2400 1100 650 1650 265 1,800,000 930,000 NO. 24F-V8 y-dir 1450 1100 560 1650 230 1,600,000 830,000 JOIST & PLANKS GLU-LAM BEAMS THICKNESS 2" TO 4" THICK 2" TO 4' WIDE 2" TO 4" THICK GRADE THAN THICKNESS 5" & THICKER BEAM & STRINGER DESIGNATION WIDTH MORE THAN 2" GREATER THAN THAN 2" GREATER DOUGLAS FIR-LARCH DESIGN VALUES 6" & WIDER 5x5 AND LARGER WIDTH NOT MORE POST & TIMBER LIGHT FRAMING ( 1 lTHE AS OV E V ALUES ARE TAKEN FROM THE NOS. (2)USE STANDARD GRADING RULE NO. 1 7. 2018 ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 Wood : Douglas-Fir/Larch Cr = 1.15 (repetitive member factor) Fv = 180 psi (for Light Framing and Joists & Planks) E = 1,500,000 psi (Const Light Framing) Fv = 170 psi (for Beams & Stringers and Posts & Timbers) E = 1,600,000 psi (#2 Joists & Planks, #1 Beams & Stringers, #1 Posts & Timbers) FLOOR ROOF MEMBER: SIZE:(35 PCF) PROPERTIES:BENDING STRESS: 1.00 (k-ft & k)Cd =1.00 (k-ft & k)C =1.25 Nominal Grade Type B (in)D (in) PLF A(in^2) S(in^3) I(in^4)Fb(psi) CF Fb x C F V max Mmax Mmax(rep) V max Mmax Mmax(rep) 2x4 Const. LF 1.5 3.50 1.3 5.3 3.1 5.4 1000 1.00 1000 0.63 0.26 0.29 0.79 0.32 0.37 2x6 #2 JP 1.5 5.50 2.0 8.3 7.6 20.8 900 1.30 1170 0.99 0.74 0.85 1.24 0.92 1.06 2x8 #2 JP 1.5 7.25 2.6 10.9 13.1 47.6 900 1.20 1080 1.31 1.18 1.36 1.63 1.48 1.70 2x10 #2 JP 1.5 9.25 3.4 13.9 21.4 98.9 900 1.10 990 1.67 1.76 2.03 2.08 2.21 2.54 2x12 #2 JP 1.5 11.25 4.1 16.9 31.6 178.0 900 1.00 900 2.03 2.37 2.73 2.53 2.97 3.41 2x14 #2 JP 1.5 13.25 4.8 19.9 43.9 290.8 900 0.90 810 2.39 2.96 3.41 2.98 3.70 4.26 4x4 Const LF 3.5 3.50 3.0 12.3 7.1 12.5 1000 1.00 1000 1.47 0.60 0.68 1.84 0.74 0.86 4x6 #2 JP 3.5 5.50 4.7 19.3 17.6 48.5 900 1.30 1170 2.31 1.72 1.98 2.89 2.15 2.47 4x8 #2 JP 3.5 7.25 6.2 25.4 30.7 111.1 900 1.30 1170 3.05 2.99 3.44 3.81 3.74 4.30 4x10 #2 JP 3.5 9.25 7.9 32.4 49.9 230.8 900 1.20 1080 3.89 4.49 5.17 4.86 5.62 6.46 4x12 #2 JP 3.5 11.25 9.6 39.4 73.8 415.3 900 1.10 990 4.73 6.09 7.00 5.91 7.61 8.76 4x14 #2 JP 3.5 13.25 11.3 46.4 102.4 678.5 900 1.00 900 5.57 7.68 8.83 6.96 9.60 6x4 #2 JP 5.5 3.50 4.7 19.3 11.2 19.7 900 1.00 900 2.31 0.84 2.89 1.05 6x6 #1 PT 5.5 5.50 7.4 30.3 27.7 76.3 1200 1.00 1200 3.43 2.77 4.29 3.47 6x8 #1 PT 5.5 7.50 10.0 41.3 51.6 193.4 1200 1.00 1200 4.68 5.16 5.84 6.45 6x10 #1 BS 5.5 9.50 12.7 52.3 82.7 393.0 1350 1.00 1350 5.92 9.31 7.40 11.6 6x12 #1 BS 5.5 11.50 15.4 63.3 121.2 697.1 1350 1.00 1350 7.17 13.6 8.96 17.0 6x14 #1 BS 5.5 13.50 18.0 74.3 167.1 1127.7 1350 0.99 1332 8.42 18.6 10.5 23.2 11.0 ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hi lls, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 Fv= 290 psi Fb= 2900 psi E=psi (STOCK BEAMS)Depth Factor=(12/D)^0.111 E=psi (COMMERCIAL) b d 3.50 x 9.50 3.50 x 11.875 3.50 x 14.0 3.50 x 16.0 3.50 x 18.0 3.50 x 20.0 3.50 x 22.0 3.50 x 24.0 3.50 x 26.0 3.50 x 28.0 5.25 x 9.500 5.25 x 11.875 5.25 x 14.0 5.25 x 16.0 5.25 x 18.0 5.25 x 20.0 5.25 x 22.0 5.25 x 24.0 5.25 x 26.0 5.25 x 28.0 5.25 x 30.0 5.25 x 32.0 5.25 x 34.0 5.25 x 36.0 5.25 x 38.0 5.25 x 40.0 5.25 x 42.0 7.00 x 9.50 7.00 x 11.875 7.00 x 14.0 7.00 x 16.0 7.00 x 18.0 7.00 x 20.0 7.00 x 22.0 7.00 x 24.0 7.00 x 26.0 7.00 x 28.0 7.00 x 30.0 7.00 x 32.0 7.00 x 34.0 7.00 x 36.0 7.00 x 40.0 7.00 x 42.0 (1) MEMBERS IN BOLD ARE COMMERCIAL SPECIAL ORDER 147 686 9604 10.8 12.2 49.9 1701 149 7690 375 27.2 35.0 488 114 49.0 56.0 394 457 5126 1195 2333 3106 4032 2000000 A V S 800 8.04 9.47 33.3 41.6 M 82 53 250 6.43 12.7 19.9 PARALLAM (PSL) BEAMS M V 125%100% I 34.0 13.53 8.04 10.04 11.84 43.7 15.9 24.8 137 592 172 224 284 73.5 84.0 105 3500 95 54.663.0 43.7 62.3 189 125.8 94.0 109.322.0 100.6 18.6 20.3 65.5 19.1 29.8 23.7 22.8 53.3 12.1 15.1 63.8 75.2 87.5 40.7 52.4 13.5 14.9 16.2 16.9 50.9 65.5 17.8 20.3 66.6 79.7 81.9 23.9 37.3 112 126 66.5 83.1 98.0 2389 3402 105 165 229 299 378 500 977 1601 504 9.64 12.1 14.2 16.2 18.3 6048 1792 2552 733 20.3 26.4 79.0 123 350 22.3 6403 24.4 12.9 16.1 18.9 21.7 24007 38.6 1201 20.1 23.7 69.9 27.1 87.4 10987.3 39.8 54.3 16.1 70.0 77.0 84.0 91.0 98.0 17.6 18.9 25.4 30.5 233 282 336 158 788 11813 116 4659 424 126 79.9 25.4 99.9 24.4 113 30.5 141 95.7 27.9 120 131 33.0 164 28.4 151 35.5 189 172 38.1 215 168 896 14336 32.5 194 40.6 243 303 179 1012 17196 34.5 218 43.1 269 48.2 272 189 1134 20412 36.5 243 336 45.7 210 1400 28000 40.6 296 50.8 370 200 1264 33.8 133 221 1544 32414 42.6 325 53.3 31.8 49.7 6211 29.8 128 37.2 406 67.9 30.5 140 467 4667 27.1 107 159 168 672 8064 32.5 150 40.6 188 154 565 47.4 252 182 789 10253 35.2 175 44.0 15750 40.6 229 50.8 219 196 915 12805 37.9 201 287 48.7 323 60.9 224 1195 19115 43.3 259 54.1 43218 56.8 433 71.1 324 210 1050 363 252 1512 15.2 2000000 395 67.7 37333 54.1 290 238 1349 27216 57.5 22927 46.0 541 280 1867 404 493 294 2058 ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 PO S T A R E A A L L O W A B L E L O A D ( K I P S ) - U N S U P P O R T E D H E I G H T I N F T ( L O A D T A B L E 1 0 0 % ) SI Z E IN 2 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2X 4 5.2 5 1. 0 0 2X 4 X 5 . 2 5 4.5 8 3 . 6 1 2 . 8 7 2 . 3 2 1 . 9 1 1 . 6 0 1 . 3 5 1 . 1 6 1 . 0 0 2X 4 5.2 5 1. 0 5 2X 4 X 5 . 2 5 4.6 7 3 . 7 2 2 . 9 8 2 . 4 2 2 . 0 0 1 . 6 7 1 . 4 2 1 . 2 2 1 . 0 5 2X 6 8.2 5 1. 6 6 2X 6 X 8 . 2 5 10 . 4 9 9 . 6 6 8 . 6 8 7 . 6 5 6 . 6 7 5 . 7 9 5 . 0 4 4 . 4 0 3 . 8 6 3 . 4 1 3 . 0 3 2 . 7 1 2 . 4 3 2 . 1 9 1 . 9 9 1 . 8 1 1 . 6 6 2X 8 10 . 8 8 2. 1 8 2X 8 X 1 0 . 8 8 14 . 3 1 3 . 9 1 3 . 3 1 2 . 5 1 1 . 7 1 0 . 7 9 . 8 8 . 8 7 . 9 6 7 . 1 7 6 . 4 6 5 . 8 4 5 . 2 9 4 . 8 1 4 . 3 9 4 . 0 1 3 . 6 8 3X4 8.7 5 4.5 7 3 . 4 6 2 . 7 0 2 . 1 5 1 . 7 6 3X4 X 8 . 7 5 7. 7 8 6 . 2 0 4 . 9 7 4 . 0 4 3 . 3 3 2 . 7 9 2 . 3 6 2 . 0 3 1 . 7 6 3X6 13 . 7 5 7. 1 4 5 . 4 2 4 . 2 3 3 . 3 8 2 . 7 6 3X6 X 1 3 . 7 5 17 . 5 1 6 . 1 1 4 . 5 1 2 . 8 1 1 . 1 9 . 7 8 . 3 9 7 . 3 3 6 . 4 3 5 . 6 8 5 . 0 5 4 . 5 1 4 . 0 5 3 . 6 6 3 . 3 1 3 . 0 2 2 . 7 6 3X8 18 . 1 3 9.3 5 7 . 1 1 5 . 5 6 4 . 4 5 3 . 6 3 3X8 X 1 8 . 1 3 23 . 9 2 3 . 1 2 2 . 1 2 0 . 9 1 9 . 4 1 7 . 9 1 6 . 3 1 4 . 7 1 3 . 3 1 1 . 9 1 0 . 8 9 . 7 8 . 8 2 8 . 0 1 7 . 3 1 6 . 6 8 6 . 1 3 4X4 12 . 2 5 10 . 9 8 . 6 8 6 . 9 6 5 . 6 6 4 . 6 7 3 . 9 0 3 . 3 1 2 . 8 4 2 . 4 6 4X6 19 . 2 5 16 . 8 1 3 . 5 1 0 . 9 8 . 8 5 7 . 3 1 6 . 1 2 5 . 1 9 4 . 4 6 3 . 8 6 4X6 X 1 9 . 2 5 24 . 5 2 2 . 5 2 0 . 3 1 7 . 9 1 5 . 6 1 3 . 5 1 1 . 7 1 0 . 3 9 . 0 1 7 . 9 6 7 . 0 7 6 . 3 1 5 . 6 7 5 . 1 2 4 . 6 4 4 . 2 3 3 . 8 6 4X8 25 . 3 8 21 . 8 1 7 . 6 1 4 . 2 1 1 . 6 9 . 6 8 . 0 4 6 . 8 3 5 . 8 6 5 . 0 8 4X8 X 2 5 . 3 8 33. 5 3 2 . 4 3 0 . 9 2 9 . 2 2 7 . 2 2 5 . 0 2 2 . 8 2 0 . 6 1 8 . 6 1 6 . 7 1 5 . 1 1 3 . 6 1 2 . 3 1 1 . 2 1 0 . 2 9 . 4 8 . 5 9 6X 6 30. 2 5 27 . 6 2 6 . 3 2 4 . 8 2 3 . 0 2 0 . 9 1 8 . 8 1 6 . 8 1 5 . 0 1 3 . 3 1 1 . 9 1 0 . 7 9 . 5 9 8 . 6 6 7 . 8 4 7 . 1 3 6 . 5 1 5 . 9 7 6X 8 41. 2 5 37. 6 3 5 . 9 3 3 . 8 3 1 . 3 2 8 . 5 2 5 . 7 2 2 . 9 2 0 . 4 1 8 . 2 1 6 . 2 1 4 . 6 1 3 . 1 1 1 . 8 1 0 . 7 9 . 7 8 . 9 8 . 1 6X 8 X 4 1 . 2 5 39. 3 3 8 . 5 3 7 . 5 3 6 . 2 3 4 . 7 3 3 . 0 3 1 . 0 2 8 . 9 2 6 . 8 2 4 . 6 2 2 . 6 2 0 . 7 1 8 . 9 1 7 . 4 1 5 . 9 1 4 . 7 1 3 . 5 6X 1 0 52. 2 5 44. 4 4 2 . 7 4 0 . 4 3 7 . 7 3 4 . 7 3 1 . 5 2 8 . 3 2 5 . 4 2 2 . 7 2 0 . 3 1 8 . 2 1 6 . 4 1 4 . 8 1 3 . 5 1 2 . 3 1 1 . 2 1 0 . 3 6X 1 0 X 5 2 . 2 5 47. 2 4 6 . 7 4 6 . 2 4 5 . 5 4 4 . 7 4 3 . 8 4 2 . 8 4 1 . 5 4 0 . 2 3 8 . 6 3 7 . 0 3 5 . 2 3 3 . 3 3 1 . 5 2 9 . 6 2 7 . 8 2 6 . 1 8X8 56. 2 5 53. 8 5 2 . 8 5 1 . 5 5 0 . 0 4 8 . 1 4 5 . 9 4 3 . 4 4 0 . 7 3 7 . 9 3 5 . 0 3 2 . 3 2 9 . 6 2 7 . 2 2 5 . 0 2 3 . 0 2 1 . 2 1 9 . 6 X I N D I C A T E S B R A C E D I N W E A K D I R E C T I O N AL L V A L U E S B A S E D O N D O U G L A S F I R - L A R C H No.1 GRADE Const No. 2 No.2 No. 2 ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 PO S T A R E A A L L O W A B L E L O A D ( K I P S ) - U N S U P P O R T E D H E I G H T I N F T ( L O A D T A B L E 1 2 5 % ) SI Z E IN 2 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2X 4 5.2 5 1. 0 1 2X 4 X 5 . 2 5 4.8 3 3 . 7 3 2 . 9 4 2 . 3 6 1 . 9 3 1 . 6 1 1 . 3 6 1 . 1 7 1 . 0 1 2X 4 5.2 5 1. 0 6 2X 4 X 5 . 2 5 4.9 7 3 . 8 7 3 . 0 6 2 . 4 7 2 . 0 3 1 . 6 9 1 . 4 3 1 . 2 3 1 . 0 6 2X 6 8.2 5 1. 6 7 2X 6 X 8 . 2 5 12 . 4 0 1 1 . 0 8 9 . 6 4 8 . 2 6 7 . 0 6 6 . 0 4 5 . 2 0 4 . 5 1 3 . 9 4 3 . 4 7 3 . 0 7 2 . 7 4 2 . 4 6 2 . 2 1 2 . 0 1 1 . 8 2 1 . 6 7 2X 8 10 . 8 8 2. 1 9 2X 8 X 1 0 . 8 8 17 . 5 1 6 . 7 1 5 . 7 1 4 . 5 1 3 . 2 1 1 . 9 1 0 . 6 9 . 4 8 . 3 7 7 . 4 7 6 . 6 9 6 . 0 1 5 . 4 2 4 . 9 1 4 . 4 6 4 . 0 7 3 . 7 3 3X4 8.7 5 4.6 7 3 . 5 1 2 . 7 2 2 . 1 7 1 . 7 7 3X4 X 8 . 7 5 8.2 8 6 . 4 5 5 . 1 1 4 . 1 2 3 . 3 8 2 . 8 2 2 . 3 9 2 . 0 4 1 . 7 7 3X6 13 . 7 5 7. 3 2 5 . 5 0 4 . 2 7 3 . 4 1 2 . 7 8 3X6 X 1 3 . 7 5 20 . 7 1 8 . 5 1 6 . 1 1 3 . 8 1 1 . 8 1 0 . 1 8 . 6 7 7 . 5 2 6 . 5 7 5 . 7 8 5 . 1 2 4 . 5 7 4 . 0 9 3 . 6 9 3 . 3 4 3 . 0 4 2 . 7 8 3X8 18 . 1 3 9.6 0 7 . 2 4 5 . 6 2 4 . 4 9 3 . 6 6 3X8 X 1 8 . 1 3 29 . 2 2 7 . 9 2 6 . 2 2 4 . 2 2 2 . 0 1 9 . 8 1 7 . 6 1 5 . 7 1 4 . 0 1 2 . 4 1 1 . 1 1 0 . 0 9 . 0 3 8 . 1 8 7 . 4 4 6 . 7 9 6 . 2 2 4X4 12 . 2 5 11 . 6 9 . 0 3 7 . 1 5 5 . 7 6 4 . 7 3 3 . 9 5 3 . 3 4 2 . 8 6 2 . 4 8 4X6 19 . 2 5 18 . 0 1 4 . 1 1 1 . 2 9 . 0 3 7 . 4 2 6 . 1 9 5 . 2 4 4 . 4 9 3 . 8 9 4X6 X 1 9 . 2 5 28 . 9 2 5 . 8 2 2 . 5 1 9 . 3 1 6 . 5 1 4 . 1 1 2 . 1 1 0 . 5 9 . 2 0 8 . 0 9 7 . 1 7 6 . 3 9 5 . 7 3 5 . 1 7 4 . 6 8 4 . 2 6 3 . 8 9 4X8 25 . 3 8 23 . 5 1 8 . 4 1 4 . 7 1 1 . 9 9 . 8 8 . 1 5 6 . 9 0 5 . 9 1 5 . 1 2 4X8 X 2 5 . 3 8 40. 9 3 9 . 0 3 6 . 7 3 3 . 9 3 0 . 8 2 7 . 7 2 4 . 7 2 1 . 9 1 9 . 5 1 7 . 4 1 5 . 6 1 4 . 0 1 2 . 6 1 1 . 5 1 0 . 4 9 . 5 8 . 7 1 6X 6 30. 2 5 33. 4 3 1 . 4 2 8 . 8 2 6 . 0 2 3 . 1 2 0 . 3 1 7 . 8 1 5 . 7 1 3 . 9 1 2 . 3 1 0 . 9 9 . 8 0 8 . 8 1 7 . 9 7 7 . 2 3 6 . 5 9 6 . 0 3 6X 8 41. 2 5 45. 6 4 2 . 8 3 9 . 3 3 5 . 4 3 1 . 5 2 7 . 7 2 4 . 3 2 1 . 4 1 8 . 9 1 6 . 7 1 4 . 9 1 3 . 4 1 2 . 0 1 0 . 9 9 . 9 9 . 0 8 . 2 6X 8 X 4 1 . 2 5 48. 5 4 7 . 1 4 5 . 4 4 3 . 3 4 0 . 8 3 8 . 0 3 5 . 0 3 2 . 0 2 9 . 1 2 6 . 4 2 3 . 9 2 1 . 7 1 9 . 7 1 8 . 0 1 6 . 4 1 5 . 0 1 3 . 8 6X 1 0 52. 2 5 54. 0 5 1 . 1 4 7 . 4 4 3 . 1 3 8 . 6 3 4 . 3 3 0 . 3 2 6 . 7 2 3 . 7 2 1 . 0 1 8 . 8 1 6 . 8 1 5 . 1 1 3 . 7 1 2 . 4 1 1 . 3 1 0 . 4 6X 1 0 X 5 2 . 2 5 58. 6 5 7 . 8 5 6 . 9 5 5 . 9 5 4 . 6 5 3 . 0 5 1 . 2 4 9 . 2 4 6 . 9 4 4 . 5 4 1 . 9 3 9 . 3 3 6 . 8 3 4 . 3 3 1 . 9 2 9 . 7 2 7 . 6 8X8 56. 2 5 66 . 4 6 4 . 7 6 2 . 6 6 0 . 0 5 6 . 8 5 3 . 3 4 9 . 4 4 5 . 4 4 1 . 5 3 7 . 8 3 4 . 4 3 1 . 2 2 8 . 5 2 6 . 0 2 3 . 8 2 1 . 8 2 0 . 0 X I N D I C A T E S B R A C E D I N W E A K D I R E C T I O N ALL V A L U E S B A S E D O N D O U G L A S F I R - L A R C H No.1 GRADE Const No. 2 No.2 No. 2 ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 PO S T A R E A A L L O W A B L E L O A D ( K I P S ) - U N S U P P O R T E D H E I G H T I N F T ( L O A D T A B L E 1 6 0 % ) SI Z E IN 2 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2X 4 5.2 5 1. 0 1 2X 4 X 5 . 2 5 5.0 3 3 . 8 3 2 . 9 9 2 . 3 9 1 . 9 5 1 . 6 3 1 . 3 7 1 . 1 7 1 . 0 1 2X 4 5.2 5 1. 0 7 2X 4 X 5 . 2 5 5.2 2 3 . 9 9 3 . 1 3 2 . 5 1 2 . 0 5 1 . 7 1 1 . 4 4 1 . 2 3 1 . 0 7 2X 6 8.2 5 1. 6 8 2X 6 X 8 . 2 5 14 . 5 6 1 2 . 4 8 1 0 . 4 9 8 . 7 8 7 . 3 7 6 . 2 4 5 . 3 4 4 . 6 1 4 . 0 1 3 . 5 2 3 . 1 1 2 . 7 7 2 . 4 8 2 . 2 3 2 . 0 2 1 . 8 4 1 . 6 8 2X 8 10 . 8 8 2. 2 1 2X 8 X 1 0 . 8 8 21 . 6 2 0 . 2 1 8 . 5 1 6 . 6 1 4 . 7 1 2 . 9 1 1 . 3 9 . 9 8 . 7 1 7 . 7 1 6 . 8 7 6 . 1 4 5 . 5 3 4 . 9 9 4 . 5 3 4 . 1 3 3 . 7 8 3X4 8.7 5 4.7 6 3 . 5 6 2 . 7 5 2 . 1 9 1 . 7 8 3X4 X 8 . 7 5 8.7 0 6 . 6 6 5 . 2 2 4 . 1 8 3 . 4 2 2 . 8 5 2 . 4 0 2 . 0 6 1 . 7 8 3X6 13 . 7 5 7. 4 6 5 . 5 8 4 . 3 1 3 . 4 3 2 . 7 9 3X6 X 1 3 . 7 5 24 . 3 2 0 . 8 1 7 . 5 1 4 . 6 1 2 . 3 1 0 . 4 8 . 9 0 7 . 6 8 6 . 6 8 5 . 8 6 5 . 1 8 4 . 6 1 4 . 1 3 3 . 7 2 3 . 3 7 3 . 0 6 2 . 7 9 3X8 18 . 1 3 9.8 1 7 . 3 4 5 . 6 8 4 . 5 2 3 . 6 8 3X8 X 1 8 . 1 3 36. 1 3 3 . 7 3 0 . 8 2 7 . 6 2 4 . 4 2 1 . 4 1 8 . 8 1 6 . 5 1 4 . 5 1 2 . 9 1 1 . 4 1 0 . 2 9 . 2 1 8 . 3 2 7 . 5 5 6 . 8 8 6 . 2 9 4X4 12 . 2 5 12 . 2 9 . 3 2 7 . 3 0 5 . 8 5 4 . 7 9 3 . 9 9 3 . 3 7 2 . 8 8 2 . 4 9 4X6 19 . 2 5 19 . 0 1 4 . 6 1 1 . 4 9 . 1 8 7 . 5 1 6 . 2 5 5 . 2 8 4 . 5 2 3 . 9 1 4X6 X 1 9 . 2 5 34. 0 2 9 . 1 2 4 . 5 2 0 . 5 1 7 . 2 1 4 . 6 1 2 . 5 1 0 . 7 9 . 3 6 8 . 2 1 7 . 2 6 6 . 4 6 5 . 7 8 5 . 2 1 4 . 7 1 4 . 2 8 3 . 9 1 4X8 25 . 3 8 24 . 8 1 9 . 1 1 5 . 0 1 2 . 1 9 . 9 8 . 2 3 6 . 9 6 5 . 9 5 5 . 1 5 4X8 X 2 5 . 3 8 50. 5 4 7 . 2 4 3 . 2 3 8 . 7 3 4 . 2 3 0 . 0 2 6 . 3 2 3 . 1 2 0 . 3 1 8 . 0 1 6 . 0 1 4 . 3 1 2 . 9 1 1 . 6 1 0 . 6 9 . 6 8 . 8 1 6X 6 30. 2 5 40. 7 3 7 . 2 3 3 . 1 2 8 . 9 2 5 . 0 2 1 . 6 1 8 . 7 1 6 . 3 1 4 . 3 1 2 . 6 1 1 . 2 9 . 9 7 8 . 9 5 8 . 0 7 7 . 3 1 6 . 6 6 6 . 0 8 6X 8 41. 2 5 55. 6 5 0 . 7 4 5 . 1 3 9 . 4 3 4 . 1 2 9 . 4 2 5 . 5 2 2 . 2 1 9 . 5 1 7 . 2 1 5 . 2 1 3 . 6 1 2 . 2 1 1 . 0 1 0 . 0 9 . 1 8 . 3 6X 8 X 4 1 . 2 5 60 . 7 5 8 . 3 5 5 . 3 5 1 . 6 4 7 . 5 4 3 . 1 3 8 . 8 3 4 . 7 3 1 . 1 2 7 . 8 2 5 . 0 2 2 . 5 2 0 . 3 1 8 . 5 1 6 . 8 1 5 . 3 1 4 . 1 6X 1 0 52. 2 5 66 . 2 6 1 . 0 5 4 . 9 4 8 . 4 4 2 . 2 3 6 . 6 3 1 . 9 2 7 . 8 2 4 . 4 2 1 . 6 1 9 . 2 1 7 . 1 1 5 . 4 1 3 . 9 1 2 . 6 1 1 . 5 1 0 . 5 6X 1 0 X 5 2 . 2 5 74 . 3 7 3 . 0 7 1 . 4 6 9 . 5 6 7 . 2 6 4 . 5 6 1 . 3 5 7 . 9 5 4 . 2 5 0 . 5 4 6 . 7 4 3 . 1 3 9 . 8 3 6 . 6 3 3 . 8 3 1 . 2 2 8 . 8 8X8 56. 2 5 83. 3 8 0 . 3 7 6 . 5 7 2 . 0 6 6 . 7 6 1 . 0 5 5 . 2 4 9 . 7 4 4 . 7 4 0 . 1 3 6 . 1 3 2 . 6 2 9 . 5 2 6 . 8 2 4 . 4 2 2 . 3 2 0 . 4 X I N D I C A T E S B R A C E D I N W E A K D I R E C T I O N AL L V A L U E S B A S E D O N D O U G L A S F I R - L A R C H No.1 GRADE Const No. 2 No.2 No. 2 ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 ROOF LOADS composite shingles 3.0 psf re-roof 3.0 psf 1/2" plywwod 1.5 psf rafters 2x6 at 16"2.0 psf insulation 0.5 psf Ceiling 3.0 psf beams/headers 1.0 psf MP&E/ misc.1.0 psf D= 15.0 psf Lr= 20.0 psf REDUCIBLE FLOOR LOADS flooring 1.0 psf 3/4" plywood 2.3 psf joist 3.0 psf ceiling 4.0 psf beams/headers 2.0 psf MP&E/ misc.2.7 psf D= 15.0 psf L= 40.0 psf EXTERIOR WALL LOADS 7/8" stucco 10.0 psf 1/2" plywood 1.5 psf 2x6 studs at 16"oc 1.5 psf insulation 0.5 psf 1/2" gyp board 2.3 psf MP&E/ misc.0.2 psf D= 16.0 psf INTERIOR WALL LOADS 1/2" gyp board 2.3 psf 1/2" plywood 1.5 psf 2x6 studs at 16"oc 1.5 psf insulation 0.5 psf 1/2" gyp board 2.3 psf MP&E/ misc.1.9 psf D= 10.0 psf A-DESIGN LOADS-comp. shingles ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 2x4 TA= 450 x 1.60 x 1.5 x 3.5 =kips 2x6 TA= 575 x 1.60 x 1.5 x 5.5 =kips 3x4 TA= 575 x 1.60 x 2.5 x 3.5 =kips 3x6 TA= 575 x 1.60 x 2.5 x 5.5 = kips TYPE 2x4 6 TA= 141 x 1.60 x x 6 = 1.25 kips 1.5FT 2x4 8 TA= 141 x 1.60 x x 8 = 1.67 kips 2FT 2x4 10 TA= 141 x 1.60 x x 10 = 2.09 kips 2.5FT 2x4 12 TA= 141 x 1.60 x x 12 = 2.51 kips 3FT 2x4 14 TA= 141 x 1.60 x x 14 = 2.92 kips 3.5FT 2x4 16 TA= 141 x 1.60 x x 16 = 3.34 kips 4FT 2x4 18 TA= 141 x 1.60 x x 18 = 3.76 kips 4.5FT 2x6 20 TA= 141 x 1.60 x x 20 = 4.18 kips 5FT 2x6 22 TA= 141 x 1.60 x x 22 = 4.60 kips 5.5FT 2x6 24 TA= 141 x 1.60 x x 24 = 5.01 kips 6FT 2x6 B1 TA= 604 x 1.60 x x 6 = 5.80 kips 0.99 2x6 B2 TA= 604 x 1.60 x x 8 = 7.73 kips 1.09 3x6 B3 TA= 725 x 1.60 x x 8 = 9.28 kips 1.09 3x6 B4 TA= 1208 x 1.60 x x 6 = 11.60 kips 1.19 3x6 B5 TA= 1208 x 1.60 x x 8 = 15.46 kips 1.31 SPLICE LENGTH 0.93 DOUBLE TOP PLATE SPLICE 3.78 7.59 0.93 0.93 8.05 12.65 0.93 0.93 0.93 0.93 0.93 1.00 0.93 0.93 1.00 1.00 1.00 1.00 ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 ROOF JOIST Tag: RJ-1 L=8.00 ft Uniform Loads D (psf) L (psf) s (in) W (plf) 15 20 16 47 Shear: Vmax < Vallow OK 0.19 K 1.24 K Flexure: Mmax < Mallow OK 0.37 k-ft 1.06 k-ft USE: 16" O.C. Deflection: Δ =0.13 in = L/743 OK 2x6 RAFTERS @ 1401 S Rosewood Ave Unit# 2& 34/22/2025 Tag: B1 Member: L = 15.50 ft No. Members: 1 L =15.50 ft 7.15 kips 7.15 kips A =56.00 in² S =149.33 in³Shear and Moment Diagrams I =1194.67 in⁴ E = 2,000,000 psi Va = 10.83 kips Ma = 34.95 k-ft CD =1.00 CF =1.00 CV =0.97 Cr =1.00 Mmáx = 27.69 k-ft Total Load L/n=240 Vmáx = 7.15 kips Live Load L/n=360 Uniform Loads Shear: D (psf)L (psf) Trib. (ft)W Vmáx = 7.15 kips 15 20 22.00 770 Vallow = 10.83 kips 66% 15 40 OK 15 60 16 9.50 152 Flexure: Mmáx = 27.69 k-ft Σw =0.922 klf Mallow = 33.86 k-ft 82% OK Point Loads (P1)x1 = 0.00 ft D (psf)L (psf) Trib. 1 (ft) Trib. 2 (ft) W Deflection: D(D+L) =0.50 in 65% L < L 371 240 Σw =0.000 kips OK Point Loads (P2)x2 = 0.00 ft D(L ONLY) = 0.24 in 46% D (psf)L (psf) Trib. 1 (ft) Trib. 2 (ft) W L < L 778 360 OK Σw = 0.000 kips USE: 1- 3.5X16 PSL 3.5x16 PSL = ௐ + ௐ + + 1401 S Rosewood Ave Unit# 2& 34/22/2025 HEADERS Tag:H1 L =4.00 ft Uniform Loads D (psf) L (psf) Trib. (ft)W 73% Shear: Vmax <Vallow Roof 15 20 30.00 1050 OK 2.10 K 2.89 K Floor Wall 98% Flexure: Mmax <Mallow Σw = 1.050 klf OK 2.10 k-ft 2.15 k-ft 39% Deflection:Δ =0.08 in = L/616 USE: OK4x6 ௠ =2 ௠ =8 1401 S Rosewood Ave Unit# 2& 34/22/2025 1401 S Rosewood Ave Unit# 2& 34/22/2025 CONTINUOUS FOOTINGS Tag: CF-1 Uniform Loads D (psf)L (psf)Trib. (ft)W ROOF 15 20 30.00 1050 DECK FLOOR WALL 16 9.50 152 Σw =1202.00 plf USE: B = 1202 plf = 0.80 ft 1500 plf 1'-0" WIDE FTG. 1401 S Rosewood Ave Unit# 2& 34/22/2025 FOOTING CAPACITY Tag: (N) CF-1 H1=24 in qa=1500 psf H2=8 in L=67.50 in D=4 in 5.63 ft W=12 in A=810 in² 5.63 ft² Uniform Loads D (psf) L (psf) Trib. (ft)W Roof 15 20 30.00 1050 Deck Floor Wall 16 9.50 152 Σw =1202.00 plf Conc. Wt. = 100 plf Abv. Grade Wuniforme= 1302 plf Pa= 8.44 kips Pload= 7.32 kips Pnet= 1.11 kips Pnet = 1.11 kips 1401 S Rosewood Ave Unit# 2& 34/22/2025 FOOTING CAPACITY Tag: (E) CF-1 H1=24 in qa=1500 psf H2=8 in L=67.50 in D=4 in 5.63 ft W=12 in A=810 in² 5.63 ft² Uniform Loads D (psf) L (psf) Trib. (ft)W Roof 15 20 30.00 1050 Deck Floor Wall 16 9.50 152 Σw =1202.00 plf Conc. Wt. = 100 plf Abv. Grade Wuniforme= 1302 plf Pa= 8.44 kips Pload= 7.32 kips Pnet= 1.11 kips Pnet = 1.11 kips 1401 S Rosewood Ave Unit# 2& 34/22/2025 CONTINUOUS FOOTINGS Tag: (E) CF-1 Uniform Loads D (psf)L (psf)Trib. (ft)W ROOF 15 20 30.00 1050 DECK FLOOR WALL 16 9.50 152 Σw =1202.00 plf USE: B = 1202 plf = 0.80 ft 1500 plf 1'-0" WIDE FTG. 1401 S Rosewood Ave Unit# 2& 34/22/2025 ASCE Hazards Report Address: 1401S S Rosewood Ave Santa Ana, California 92707 Standard: ASCE/SEI 7-22 Latitude: 33.728941 Risk Category: II Longitude: -117.881771 Soil Class: Default Elevation: 65.44107110986225 ft (NAVD 88) Page 1 of 4 https://ascehazardtool.org/ Tue Apr 09 2024 1401 S Rosewood Ave Unit# 2& 34/22/2025 PGA M :0.66 SMS :1.74 SM1 :1.2 SDS :1.16 SD1 :0.8 T L :8 SS :1.48 S1 :0.53 VS30 :260 Seismic Design Category: D Multi-Period Design Spectrum S (g) vs T(s)a Multi-Period MCE Spectrum R S (g) vs T(s) a Two-Period Design Spectrum S (g) vs T(s)a Two-Period MCE Spectrum R S (g) vs T(s) a Design Vertical Response Spectrum Vertical ground motion data has not yet been made available by USGS. MCE Vertical Response SpectrumR Vertical ground motion data has not yet been made available by USGS. Seismic DefaultSite Soil Class: Results: Page 2 of 4 https://ascehazardtool.org/ Tue Apr 09 2024 1401 S Rosewood Ave Unit# 2& 34/22/2025 INPUT DATA B I = 1.00 Category II V = 110.00 mph Kzt = 1.00 Flat he = 9.50 ft hr = 15.50 ft L = 55.50 ft B = 33.50 ft A = 10.00 ft2 DESIGN SUMMARY Max horizontal force normal to building length, L, face =8.60 kips X 0.6=5.16 kips (ASD)=2.78psf Max horizontal force normal to building length, B, face =5.79 kips X 0.6=3.47 kips (ASD)=1.87psf Max total horizontal torsional load =57 ft-kips Max total upward force =27.40 kips ANALYSIS Velocity pressure qh = 0.00256 Kh Kzt Kd V 2 I = 18.43 psf where: qh = velocity pressure at mean roof height, h. Kh = velocity pressure exposure coefficient evaluated at height, h, =0.70 Kd = wind directionality factor =0.85 h = mean roof height = 12.50 ft < 60 ft, [Satisfactory] Design pressures for MWFRS p = qh [(G Cpf )-(G Cpi )] where: p = pressure in appropriate zone G Cp f = product of gust effect factor and external pressure coefficient G Cp i = product of gust effect factor and internal pressure coefficient = 0.18 or -0.18 a = width of edge strips, MAX[ MIN(0.1B, 0.4h), 0.04B,3] =3.35 ft Net Pressures (psf), Basic Load Cases 19.71 0.00 (+GCp i ) (-GCp i ) (+GCp i ) (-GCp i ) 1 0.53 6.40 13.04 0.40 4.05 10.69 2 -0.69 -16.03 -9.40 -0.69 -16.03 -9.40 3 -0.48 -12.12 -5.49 -0.37 -10.14 -3.50 4 -0.43 -11.19 -4.56 -0.29 -8.66 -2.03 1E 0.80 11.36 17.99 0.61 7.93 14.56 2E -1.07 -23.04 -16.40 -1.07 -23.04 -16.40 3E -0.69 -15.98 -9.34 -0.53 -13.09 -6.45 4E -0.64 -15.04 -8.40 -0.43 -11.24 -4.61 5 -0.45 -11.61 -4.98 -0.45 -11.61 -4.98 6 -0.45 -11.61 -4.98 -0.45 -11.61 -4.98 Net Pressures (psf), Torsional Load Cases 19.71 (+GCp i ) (-GCp i ) 1T 0.53 1.60 3.26 2T -0.69 -4.01 -2.35 3T -0.48 -3.03 -1.37 4T -0.43 -2.80 -1.14 0.00 (+GCp i ) (-GCp i ) 1T 0.40 1.01 2.67 2T -0.69 -4.01 -2.35 3T -0.37 -2.53 -0.88 4T -0.29 -2.17 -0.51 G Cp f Surface WIND ANALYSIS FOR LOW-RISE BUILDING ( BASED ON ASE 7-16/ IBC 2021/ CBC 2022) Roof angle q = Surface Net Pressure withG Cp f Importance factor Building length Building height to ridge Building height to eave Topographic factor Basic wind speed Roof angle q = G Cp f Net Pressure with Effective area of components Exposure category (B, C or D) Roof angle q = Building width Net Pressure with Surface Roof angle q = G Cp f Net Pressure with 1401 S Rosewood Ave Unit# 2& 34/22/2025 Basic Load Cases in Transverse Direction Basic Load Cases in Longitudinal Direction Area Area (ft2) (+GCp i ) (-GCp i )(ft2) (+GCp i ) (-GCp i ) 1 464 2.97 6.04 1 347 1.41 3.71 2 868 -13.92 -8.16 2 790 -12.67 -7.43 3 868 -10.53 -4.77 3 790 -8.01 -2.77 4 464 -5.19 -2.11 4 347 -3.01 -0.70 1E 64 0.72 1.15 1E 72 0.57 1.04 2E 119 -2.75 -1.96 2E 197 -4.55 -3.24 3E 119 -1.90 -1.11 3E 197 -2.58 -1.27 4E 64 -0.96 -0.53 4E 72 -0.81 -0.33 Horiz. 8.41 8.41 Horiz. 5.79 5.79 Vert. -27.40 -15.06 Vert. -26.18 -13.84 10 psf min. Horiz. 8.60 8.60 10 psf min. Horiz. 4.19 4.19 Sec. 6.1.4.1 Vert. -18.59 -18.59 Sec. 6.1.4.1 Vert. -18.59 -18.59 Torsional Load Cases in Transverse Direction Torsional Load Cases in Longitudinal Direction Area Area (ft2) (+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )(ft 2) (+GCp i ) (-GCp i ) (+GCp i ) (-GCp i ) 1 200 1.28 2.61 16 32 1 138 0.56 1.47 3 7 2 375 -6.01 -3.52 -25 -14 2 592 -9.50 -5.57 44 26 3 375 -4.54 -2.06 19 8 3 592 -6.01 -2.07 -28 -10 4 200 -2.24 -0.91 27 11 4 138 -1.19 -0.28 6 1 1E 64 0.72 1.15 18 28 1E 72 0.57 1.04 8 14 2E 119 -2.75 -1.96 -23 -16 2E 197 -4.55 -3.24 21 15 3E 119 -1.90 -1.11 16 9 3E 197 -2.58 -1.27 -12 -6 4E 64 -0.96 -0.53 23 13 4E 72 -0.81 -0.33 11 4 1T 264 0.42 0.86 -6 -12 1T 209 0.21 0.56 -2 -4 2T 494 -1.98 -1.16 9 5 2T 790 -3.17 -1.86 -30 -17 3T 494 -1.50 -0.68 -7 -3 3T 790 -2.00 -0.69 19 6 4T 264 -0.74 -0.30 -10 -4 4T 209 -0.45 -0.11 -3 -1 57 57 36.2 36.2 Design pressures for components and cladding p = qh[ (G Cp) - (G Cpi)] where: p = pressure on component pmin = 10 psf (Sec. 6.1.4.2, pg 21) G Cp = external pressure coefficient. see table below Effective Area (ft2) GCP - GCP GCP - GCP GCP - GCP GCP - GCP GC P - GCP Comp.10 0.50 -0.90 0.50 -1.70 0.50 -2.60 1.00 -1.10 1.00 -1.40 Positive Negative Positive Negative Positive Negative Positive Negative Positive Negative 12.53 -19.91 12.53 -34.65 12.53 -51.24 21.75 -23.59 21.75 -29.12 Surface Pressure (k) with Zone 1 Zone 2 Total Horiz. Torsional Load, MT Comp. & Cladding Zone 1 Zone 2 Surface Pressure ( psf ) Torsion (ft-k) S Surface Pressure (k) withPressure (k) with S Torsion (ft-k) Total Horiz. Torsional Load, MT Zone 5 Zone 3 Zone 4 Zone 5 Zone 3 Zone 4 Pressure (k) with Surface 1401 S Rosewood Ave Unit# 2& 34/22/2025 SEISMIC BASE SHEAR (ASCE7-22) Latitude: 33.728941 Longitude: -117.881771 SITE CLASS: D (Table 20.3-1)ρ= 1.3 R= 6.5 (Table 12.2-1)Ie= 1 (Section 21.4) 1.740 0 2.100 0 (11.4-3) 1.160 (11.4-4) 1.4 0.24137931 1.20689655 See on Figs. 22-14 through 22-17 0.02 9.500 0.75 0.108 W= Effective seismeic weight (GOVERNS) For S1 is equal to greater than 0.6g 0.162 W 1.990 W 0.178 0.232 W Strength Level 0.162 W Allowable Stress Design ெ = ெ = = 2 3 ெ = = 2 3 ெ = = ℎ = ℎ = = = = = 0.01 = W =ρW = = == = = = 0.7 = = = = 1401 S Rosewood Ave Unit# 2& 34/22/2025 SEISMIC ANALYSIS WEIGHT Level 1 W roof = 20 psf x 1343 ft^2 = 26.87 kips W wall = 16 psf x 768 ft^2 = 12.28 kips WR = 39.15 kips BASE SHEAR 0.162 x 39.15 kips = 6.36 kips F1= DISTRIBUTION OF BASE SHEAR 1 Level 2 or more levels W TOTAL 39.15 kips 4.733 psf = ∗ = ∗ = = ∗ ∗ ∗ + ∗ + + ⋯ ∗ = ∗ 1401 S Rosewood Ave Unit# 2& 34/22/2025 1401 S Rosewood Ave Unit# 2& 34/22/2025 F1= 4.730 psf SW U-FORCE T.A. FORCE L1 L2 L3 L4 X1 4.73 73.30 0.35 KIPS 4.50 ft X2 4.73 617.60 2.92 KIPS 19.00 ft X3 4.73 617.60 2.92 KIPS 4.25 ft 5.83 ft Y1 4.73 73.30 0.35 KIPS 12.00 ft Y2 4.73 648.18 3.07 KIPS 8.00 ft Y3 4.73 137.15 0.65 KIPS 14.25 ft FORCES LEVEL 1 LENGHT WALLS 1401 S Rosewood Ave Unit# 2& 34/22/2025 DATA: SEISMIC GOVERNS Load Comb.: (0.6-.14SDS) D + 0.7 E SDS=1.16 TAG:FORCE HEIGHT X1.1 F1= 0.35 kips h1= 9.50 ft L= 4.50 ft 4.50 ft 0.35 kips 9.50 ft SHEAR STRESS 347 lbs 4.50 ft OVERTURNING WALL:X1.1 4.50 ft LEVEL 1 MOT 3.29 3.29 k-ft Uniform Loads Load Unit Load Tributary W (psf)(ft)(plf) ROOF 15 16.50 248 WALL 16 9.50 152 Σw =400 plf USE: DLR=0.44 TYPE: SHEARWALL h/w= 2.11 1.25-0.125h/b= 0.99 Vallow= 335 PLF OK ST-1 USE: HDU2 4 x Tallow= 3.08 kips OK ST-1 w/ HDU2 H.D. S/LTT20 77 plf SHEARWALL CALCULATIONS LEVEL 1 6 4.04 k-ft 4 POST 0.34 kips ் ் = ் ் = ℎ் ் = =் ் ∗ 1000 ் ் == = ∗ ் ் ∗ ℎ = = ( ∗ ( ) ) 2 = = − ( ∗ ) = 1401 S Rosewood Ave Unit# 2& 34/22/2025 DATA: SEISMIC GOVERNS Load Comb.: (0.6-.14SDS) D + 0.7 E SDS=1.16 TAG:FORCE HEIGHT X2.1 F1= 2.92 kips h1= 9.50 ft L= 19.00 ft 19.00 ft 2.92 kips 9.50 ft SHEAR STRESS 2921 lbs 19.00 ft OVERTURNING WALL: X2.1 19.00 ft LEVEL 1 MOT 27.75 27.75 k-ft Uniform Loads Load Unit Load Tributary W (psf)(ft)(plf) ROOF 15 16.50 248 WALL 16 9.50 152 Σw =400 plf USE: DLR= 0.44 TYPE: SHEARWALL h/w= 0.50 Vallow= 340 PLF OK ST-1 USE: HDU2 4 x Tallow= 3.08 kips OK ST-1 w/ HDU2 H.D. NO 154 plf SHEARWALL CALCULATIONS LEVEL 1 6 72.11 k-ft 4 POST 0.00 kips ் ் = ் ் = ℎ் ் = =் ் ∗ 1000 ் ் == = ∗ ் ் ∗ ℎ = = ( ∗ ( ) ) 2 = = − ( ∗ ) = 1401 S Rosewood Ave Unit# 2& 34/22/2025 DATA: SEISMIC GOVERNS Load Comb.: (0.6-.14SDS) D + 0.7 E SDS=1.16 TAG:FORCE HEIGHT X3.1 X3.2 F1= 2.92 kips h1= 9.50 ft L= 4.25 ft L= 5.83 ft 10.08 ft 2.92 kips 9.50 ft SHEAR STRESS 2921 lbs 10.08 ft OVERTURNING WALL:X3.1 4.25 ft LEVEL 1 MOT 11.70 11.70 k-ft Uniform Loads Load Unit Load Tributary W (psf)(ft)(plf) ROOF 15 16.50 248 WALL 16 9.50 152 Σw =400 plf USE: DLR=0.44 TYPE: SHEARWALL h/w= 2.24 1.25-0.125h/b= 0.97 Vallow= 330 PLF OK ST-3 USE: HDU2 4 x Tallow= 3.08 kips OK ST-6 w/ HDU2 H.D. S/HTT4 290 plf SHEARWALL CALCULATIONS LEVEL 1 6 3.61 k-ft 4 POST 2.38 kips ் ் = ் ் = ℎ் ் = =் ் ∗ 1000 ் ் == = ∗ ் ் ∗ ℎ = = ( ∗ ( ) ) 2 = = − ( ∗ ) = 1401 S Rosewood Ave Unit# 2& 34/22/2025 WALL:X3.2 5.83 ft LEVEL 1 MOT 16.05 16.05 k-ft Uniform Loads Load Unit Load Tributary W (psf)(ft)(plf) ROOF 15 16.50 248 WALL 16 9.50 152 Σw = 400 plf USE: TYPE: SHEARWALL h/w= 1.63 Vallow= 340 PLF OK ST-3 USE: HDU2 4 x Tallow= 3.08 kips OK ST-6 w/ HDU2 H.D. S/HTT4 6 4 POST 6.79 k-ft 2.24 kips = ∗ ் ் ∗ ℎ = = ( ∗ ( ) ) 2 = = ∗ ( ∗ ) = 1401 S Rosewood Ave Unit# 2& 34/22/2025 DATA: SEISMIC GOVERNS Load Comb.: (0.6-.14SDS) D + 0.7 E SDS=1.16 TAG:FORCE HEIGHT Y1.1 F1= 2.98 kips h1= 9.50 ft L= 12.00 ft 12.00 ft 2.98 kips 9.50 ft SHEAR STRESS 2981 lbs 12.00 ft OVERTURNING WALL: Y1.1 12.00 ft LEVEL 1 MOT 28.32 28.32 k-ft Uniform Loads Load Unit Load Tributary W (psf)(ft)(plf) ROOF 15 16.50 248 WALL 16 9.50 152 Σw =400 plf USE: DLR= 0.44 TYPE: SHEARWALL h/w= 0.79 Vallow= 340 PLF OK ST-1 USE: HDU2 4 x Tallow= 3.08 kips OK ST-5 w/ HDU2 H.D. S/HTT4 248 plf SHEARWALL CALCULATIONS LEVEL 1 6 28.76 k-ft 4 POST 1.31 kips ் ் = ் ் = ℎ் ் = =் ் ∗ 1000 ் ் == = ∗ ் ் ∗ ℎ = = ( ∗ ( ) ) 2 = = − ( ∗ ) = 1401 S Rosewood Ave Unit# 2& 34/22/2025 DATA: SEISMIC GOVERNS Load Comb.: (0.6-.14SDS) D + 0.7 E SDS=1.16 TAG:FORCE HEIGHT Y2.1 F1= 3.07 kips h1= 9.50 ft L= 8.00 ft 8.00 ft 3.07 kips 9.50 ft SHEAR STRESS 3066 lbs 8.00 ft OVERTURNING WALL:Y2.1 8.00 ft LEVEL 1 MOT 29.13 29.13 k-ft Uniform Loads Load Unit Load Tributary W (psf)(ft)(plf) ROOF 15 16.50 248 WALL 16 9.50 152 Σw =400 plf USE: DLR= 0.44 TYPE: SHEARWALL h/w= 1.19 Vallow= 510 PLF OK ST-4 USE: HDU2 4 x Tallow= 3.08 kips OK ST-6 w/ HDU2 H.D. S/HTT4 383 plf SHEARWALL CALCULATIONS LEVEL 1 4 12.78 k-ft 4 POST 2.94 kips ் ் = ் ் = ℎ் ் = =் ் ∗ 1000 ் ் == = ∗ ் ் ∗ ℎ = = ( ∗ ( ) ) 2 = = − ( ∗ ) = 1401 S Rosewood Ave Unit# 2& 34/22/2025 DATA: SEISMIC GOVERNS Load Comb.: (0.6-.14SDS) D + 0.7 E SDS=1.16 TAG:FORCE HEIGHT Y3.1 F1= 0.65 kips h1= 9.50 ft L= 14.25 ft 14.25 ft 0.65 kips 9.50 ft SHEAR STRESS 649 lbs 14.25 ft OVERTURNING WALL: Y3.1 14.25 ft LEVEL 1 MOT 6.16 6.16 k-ft Uniform Loads Load Unit Load Tributary W (psf)(ft)(plf) ROOF 15 16.50 248 WALL 16 9.50 152 Σw =400 plf USE: DLR= 0.44 TYPE: SHEARWALL h/w= 0.67 Vallow= 340 PLF OK ST-1 USE: HDU2 4 x Tallow= 3.08 kips OK ST-1 w/ HDU2 H.D. NO 46 plf SHEARWALL CALCULATIONS LEVEL 1 6 40.56 k-ft 4 POST 0.00 kips ் ் = ் ் = ℎ் ் = =் ் ∗ 1000 ் ் == = ∗ ் ் ∗ ℎ = = ( ∗ ( ) ) 2 = = − ( ∗ ) = 1401 S Rosewood Ave Unit# 2& 34/22/2025 RFG J A� - lFARWA I SCH SHEARWALL SCHEDULE MARK SHEATHING NAIL EDGE FIELD SILL TO SILL TO ALLOW.SHEAR SIZE NAIL NAIL SHEAR WALL( 1 ) (2) SPACING SPACING WOOD CONN. (1) CONC.CONN. (1)(PLF) TYPE(3) 15/32 STR I O.S. 10d 6" 12" SDS1/4"x6" @ 16"2x: 5/8"1/J A.B. @ 32"340 I3x: 5/8"1/J A.B. @ 48" 15/32 STR I O.S. 10d 4" 12" SDS1/4"x6" @ 12" 3x: 5/8"1/J A.B. @ 32" 510 JI ill 15/32 STR I O.S. 10d 3" STGR( 4) 12" SDS1/4"x6" @ 9" 3x: 5/8"1/J A.B. @ 24" 665 JI In 15/32 STR I O.S. 10d 2" STGR( 4) 12" SDS1/4''x6" @ 6" 3x: 5/8"1/J A.B. @ 16" 870 JI &15/32 STR I D.S. 10d 4" 12" SDS1/4''x6" @ 6" 3x: 5/8"1/J A.B. @ 16" 1020 III �15/32 STR I D.S. 10d 3" STGR( 4) 12" SDS1/4''x6" @ 4" 3x: 5/8"1/J A.B. @ 12" 1330 K A 15/32 STR I D.S. 10d 2" STGR( 4) 12" SDS1/4''x6" @ 3" 3x: 5/8"1/J A.B. @ 8" 1740 K SHEARWALL NOTES: (1) 0.5. INDICATE5 5HEATI-HNG ON ONE 51DE OF WALL AS 5HOWN ON FLAN5. D.5. INDICATE5 DOU6LE 51DED 5HEARWALL: 5HEATHING ON 60TH 51DE5 OF WALL (2) USE COMMON WIRE NAIL5 FOR ALL STRUCT-1 5HEATHING. ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 REMARKS 4x4 4x4 4X4 4X6 4X67.15 10.83 ALLOWABLE 75% 2.31 3.42 4.23 6X6HDU14 3.075 4.565 5.645 6.970 9.535 14.445 5.23 HDU5 HDU8 HDU11 HOLDOWNS HDU2 HDU4 HD ALLOWABLE UPLIFT ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 STRAP HD SCHEDULE TAG STRAP TYPE END NAILS REO. WITHIN CAPACITY LA CITYLENGTH END LENGTH "L 1"(KIPS) (KIPS)"L1" ST-1 CS18 10" 10 -10d 1.37 1.03 ST-2 CS16 12" 11 -10d 1.705 1.28 ST-3 2-CS18 10" 20 -10d 2.74 2.06 ST-4 2-CS16 12" 22 -10d 3.41 2.56 ST-5 CMSTC16 23" 33 -16d SINKERS 4.59 3.44 ST-6 CMST14 30" 38 -16d 6.49 4.87 ST-7 CMST12 39" 50 -16d 9.22 6.91 I-ID 5TRA P « NAILING FER 5CI-IEDI.ILE 1 I-IOI.. DOl+I PO ST FER PLAN < 4x MINJ i 5TLl6 POS T TO MATCI-IA60YE FLOOR FRAM ING -------'==-t-- JOl5T OTI-IER DIRECTION <1-11-ERE OCCUR5 > _ __,_6EAM FER PLAN 11 lYPICAL STRAP HOLDOWN EQUIVALENT HOLD DOWN @ FOUNDATION HDU2 HDU2 HDU2 HDU4 HDU5 HDU8 HDU11 I-ID 5TRAP « NAILING FER 5CI-IED ULE I-IO LDoi,.¡¡,..¡ PO ST FER PLAN < 4x MIN.) 5TU6 PO ST TO MATCI-I AeOYE FLOOR FRAM ING JOl5T OTI-IER DIRECTION (1-11-!ERE OCCU !e > -------+--1--I-IO LDoi,.¡¡,..¡ PO ST FER PLAN <MATCl-l 51ZE « ALIGN w/ AeOYE > 5EE NOTE '3 AND EQU IYAL ENT I-ID TA6LE NOTE: IF END LENGi TI-I 'LI' 15 GRE ATER TI-IAN 6EAM DEPTI-I, CAREFU LLY 6END 5TRA P AROI.ND 60 TTa-l Cf 6EAM AND NAIL ACCORD ING LY.lYPICAL STRAP HOLDOWN _.....---- .---I-ID 5TRAP « NAILING FER 5CI-IEDI.ILE I-IOI.. DOl+I PO ST FER PLAN < 4x MINJ lYPICAL STRAP HOLDOWN TO BEAM NOTE: IF END L�TI-I 'LI' 15 GRE ATER TI-IAN 6EAM DEPTI-I 1401 S Rosewood Ave Unit# 2& 34/22/2025 Structural Calculations for 1401 S ROSEWOOD AVE REMODEL 1401 S ROSEWOOD SANTA ANA SANTA ANA, CALIFORNIA 92707 09-Sep-24 JOB NO. : 24-088 4 6 8 N O R T H C A M D E N D R I V E 1 3 1 E , B E V E R L Y H I L L S , C A L I F O R N I A 9 0 2 1 0 T : 3 1 0 . 6 5 8 . 1 2 2 5 W W W . E S T R U C T U R A U S A . C O M . 1401 S Rosewood Ave Unit# 2& 34/22/2025 DESIGN CRITERIA 1 Soil supporting footings is natural grade or engineered fill. 2 Soil allowable bearing pressure used in design_______________________________ 3 Footing shall extend_____ minimum into undisturbed soil or_____ below finish grade whichever is lower. 4 All concrete shall develop a minimum compressive strength of 2500 psi in 28 days. 5 Reinforcing steel shall conform to ASTM 615, Grade 60. 6 Structural steel shall conform to the following: Wide flange shapes ASTM A992 TS shapes ASTM A500, Grade B Pipe shapes ASTM A53 , Grade B Other rolled shapes, Bars and plates ASTM A36 7 Structural steel shall be fabricated in a shop of an approved fabricator. 8 All welding shall be done by Certified Welders. 9 Concrete Block shall conform to ASTM C90, Grade N-1. 10 Grout shall develop 2000 psi in 28 days. 11 Mortar shall be Type S and develop 1800 psi in 28 days. 12 All lumber shall be grade marked Douglas Fir. (Grading rule No. 17) Light Framing Construction Joist & Planks No. 2 Beams & Stringers No. 1 Posts & Timbers No. 1 13 Glue Laminated Timbers shall be combination No. 24F-V8. 14 Plywood shall conform to PS 1-95, Structural 1. 15 All material and workmanship shall conform to the requirements of 2022 California Building Code. ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1500 PSF 24"24" 1401 S Rosewood Ave Unit# 2& 34/22/2025 Fb Ft Fcperp.Fc Fv E E min CONSTRUCTION 1000 650 625 1650 180 1,500,000 550,000 NO. 2 900 575 625 1350 180 1,600,000 580,000 NO. 1 1200 825 625 1000 170 1,600,000 580,000 NO. 1 1350 675 625 925 170 1,600,000 580,000 COMBINATION 2400 1100 650 1650 265 1,800,000 930,000 NO. 24F-V8 y-dir 1450 1100 560 1650 230 1,600,000 830,000 JOIST & PLANKS GLU-LAM BEAMS THICKNESS 2" TO 4" THICK 2" TO 4' WIDE 2" TO 4" THICK GRADE THAN THICKNESS 5" & THICKER BEAM & STRINGER DESIGNATION WIDTH MORE THAN 2" GREATER THAN THAN 2" GREATER DOUGLAS FIR-LARCH DESIGN VALUES 6" & WIDER 5x5 AND LARGER WIDTH NOT MORE POST & TIMBER LIGHT FRAMING ( 1 lTHE AS OVE VALUES ARE TAKEN FROM THE NOS. (2)USE STANDARD GRADING RULE NO. 1 7. 2018 ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 Wood :Douglas-Fir/Larch Cr = 1.15 (repetitive member factor)Fv =180 psi (for Light Framing and Joists & Planks) E = 1,500,000 psi (Const Light Framing)Fv =170 psi (for Beams & Stringers and Posts & Timbers) E = 1,600,000 psi (#2 Joists & Planks, #1 Beams & Stringers, #1 Posts & Timbers) FLOOR ROOF MEMBER:SIZE:(35 PCF)PROPERTIES:BENDING STRESS:1.00 (k-ft & k)Cd =1.00 (k-ft & k)C =1.25 Nominal Grade Type B (in)D (in)PLF A(in^2)S(in^3)I(in^4)Fb(psi)CF Fb x CF Vmax Mmax Mmax(rep) Vmax Mmax Mmax(rep) 2x4 Const. LF 1.5 3.50 1.3 5.3 3.1 5.4 1000 1.00 1000 0.63 0.26 0.29 0.79 0.32 0.37 2x6 #2 JP 1.5 5.50 2.0 8.3 7.6 20.8 900 1.30 1170 0.99 0.74 0.85 1.24 0.92 1.06 2x8 #2 JP 1.5 7.25 2.6 10.9 13.1 47.6 900 1.20 1080 1.31 1.18 1.36 1.63 1.48 1.70 2x10 #2 JP 1.5 9.25 3.4 13.9 21.4 98.9 900 1.10 990 1.67 1.76 2.03 2.08 2.21 2.54 2x12 #2 JP 1.5 11.25 4.1 16.9 31.6 178.0 900 1.00 900 2.03 2.37 2.73 2.53 2.97 3.41 2x14 #2 JP 1.5 13.25 4.8 19.9 43.9 290.8 900 0.90 810 2.39 2.96 3.41 2.98 3.70 4.26 4x4 Const LF 3.5 3.50 3.0 12.3 7.1 12.5 1000 1.00 1000 1.47 0.60 0.68 1.84 0.74 0.86 4x6 #2 JP 3.5 5.50 4.7 19.3 17.6 48.5 900 1.30 1170 2.31 1.72 1.98 2.89 2.15 2.47 4x8 #2 JP 3.5 7.25 6.2 25.4 30.7 111.1 900 1.30 1170 3.05 2.99 3.44 3.81 3.74 4.30 4x10 #2 JP 3.5 9.25 7.9 32.4 49.9 230.8 900 1.20 1080 3.89 4.49 5.17 4.86 5.62 6.46 4x12 #2 JP 3.5 11.25 9.6 39.4 73.8 415.3 900 1.10 990 4.73 6.09 7.00 5.91 7.61 8.76 4x14 #2 JP 3.5 13.25 11.3 46.4 102.4 678.5 900 1.00 900 5.57 7.68 8.83 6.96 9.60 6x4 #2 JP 5.5 3.50 4.7 19.3 11.2 19.7 900 1.00 900 2.31 0.84 2.89 1.05 6x6 #1 PT 5.5 5.50 7.4 30.3 27.7 76.3 1200 1.00 1200 3.43 2.77 4.29 3.47 6x8 #1 PT 5.5 7.50 10.0 41.3 51.6 193.4 1200 1.00 1200 4.68 5.16 5.84 6.45 6x10 #1 BS 5.5 9.50 12.7 52.3 82.7 393.0 1350 1.00 1350 5.92 9.31 7.40 11.6 6x12 #1 BS 5.5 11.50 15.4 63.3 121.2 697.1 1350 1.00 1350 7.17 13.6 8.96 17.0 6x14 #1 BS 5.5 13.50 18.0 74.3 167.1 1127.7 1350 0.99 1332 8.42 18.6 10.5 23.2 11.0 ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 Fv=290 psi Fb=2900 psi E=psi (STOCK BEAMS)Depth Factor=(12/D)^0.111 E=psi (COMMERCIAL) b d 3.50 x 9.50 3.50 x 11.875 3.50 x 14.0 3.50 x 16.0 3.50 x 18.0 3.50 x 20.0 3.50 x 22.0 3.50 x 24.0 3.50 x 26.0 3.50 x 28.0 5.25 x 9.500 5.25 x 11.875 5.25 x 14.0 5.25 x 16.0 5.25 x 18.0 5.25 x 20.0 5.25 x 22.0 5.25 x 24.0 5.25 x 26.0 5.25 x 28.0 5.25 x 30.0 5.25 x 32.0 5.25 x 34.0 5.25 x 36.0 5.25 x 38.0 5.25 x 40.0 5.25 x 42.0 7.00 x 9.50 7.00 x 11.875 7.00 x 14.0 7.00 x 16.0 7.00 x 18.0 7.00 x 20.0 7.00 x 22.0 7.00 x 24.0 7.00 x 26.0 7.00 x 28.0 7.00 x 30.0 7.00 x 32.0 7.00 x 34.0 7.00 x 36.0 7.00 x 40.0 7.00 x 42.0 (1) MEMBERS IN BOLD ARE COMMERCIAL SPECIAL ORDER 147 686 9604 10.8 12.2 49.9 1701 149 7690 375 27.2 35.0 488 11449.0 56.0 394 457 5126 1195 2333 3106 4032 2000000 A VS 800 8.04 9.47 33.3 41.6 M 82 53 250 6.43 12.7 19.9 PARALLAM (PSL) BEAMS M V 125%100% I 34.0 13.53 8.04 10.04 11.84 43.7 15.9 24.8 137 592 172 224 284 73.5 84.0 105 3500 95 54.663.0 43.7 62.3 189 125.8 94.0 109.322.0 100.6 18.6 20.3 65.5 19.1 29.8 23.7 22.8 53.3 12.1 15.1 63.8 75.2 87.5 40.7 52.4 13.5 14.9 16.2 16.9 50.9 65.5 17.8 20.3 66.6 79.7 81.9 23.9 37.3 112 126 66.5 83.1 98.0 2389 3402 105 165 229 299 378 500 977 1601 504 9.64 12.1 14.2 16.2 18.3 6048 1792 2552 733 20.3 26.4 79.0 123 350 22.3 6403 24.4 12.9 16.1 18.9 21.7 24007 38.6 1201 20.1 23.7 69.9 27.1 87.4 10987.3 39.8 54.3 16.1 70.0 77.0 84.0 91.0 98.0 17.6 18.9 25.4 30.5 233 282 336 158 788 11813 116 4659424 126 79.9 25.4 99.9 24.4 113 30.5 141 95.7 27.9 120 131 33.0 164 28.4 151 35.5 189 172 38.1 215 168 896 14336 32.5 194 40.6 243 303 179 1012 17196 34.5 218 43.1 269 48.2 272 189 1134 20412 36.5 243 336 45.7 210 1400 28000 40.6 296 50.8 370 200 1264 33.8 133 221 1544 32414 42.6 325 53.3 31.8 49.7 6211 29.8 128 37.2 406 67.9 30.5 140 467 4667 27.1 107 159 168 672 8064 32.5 150 40.6 188 154 565 47.4 252 182 789 10253 35.2 175 44.0 15750 40.6 229 50.8 219 196 915 12805 37.9 201 287 48.7 323 60.9 224 1195 19115 43.3 259 54.1 43218 56.8 433 71.1 324 210 1050 363 252 1512 15.2 2000000 395 67.737333 54.1 290238 1349 27216 57.522927 46.0 541 280 1867 404 493 294 2058 ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 PO S T A R E A A L L O W A B L E L O A D ( K I P S ) - U N S U P P O R T E D H E I G H T I N F T ( L O A D T A B L E 10 0 % ) SI Z E IN 2 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2X 4 5 . 2 5 1 . 0 0 2X 4 X 5 . 2 5 4 . 5 8 3 . 6 1 2 . 8 7 2 . 3 2 1 . 9 1 1 . 6 0 1 . 3 5 1 . 1 6 1 . 0 0 2X 4 5 . 2 5 1 . 0 5 2X 4 X 5 . 2 5 4 . 6 7 3 . 7 2 2 . 9 8 2 . 4 2 2 . 0 0 1 . 6 7 1 . 4 2 1 . 2 2 1 . 0 5 2X 6 8 . 2 5 1 . 6 6 2X 6 X 8 . 2 5 1 0 . 4 9 9 . 6 6 8 . 6 8 7 . 6 5 6 . 6 7 5 . 7 9 5 . 0 4 4 . 4 0 3 . 8 6 3 . 4 1 3 . 0 3 2 . 7 1 2 . 4 3 2 . 1 9 1 . 9 9 1 . 8 1 1 . 6 6 2X 8 1 0 . 8 8 2 . 1 8 2X 8 X 1 0 . 8 8 1 4 . 3 1 3 . 9 1 3 . 3 1 2 . 5 1 1 . 7 1 0 . 7 9 . 8 8 . 8 7 . 9 6 7 . 1 7 6 . 4 6 5 . 8 4 5 . 2 9 4 . 8 1 4 . 3 9 4 . 0 1 3 . 6 8 3X 4 8 . 7 5 4 . 5 7 3 . 4 6 2 . 7 0 2 . 1 5 1 . 7 6 3X 4 X 8 . 7 5 7 . 7 8 6 . 2 0 4 . 9 7 4 . 0 4 3 . 3 3 2 . 7 9 2 . 3 6 2 . 0 3 1 . 7 6 3X 6 1 3 . 7 5 7 . 1 4 5 . 4 2 4 . 2 3 3 . 3 8 2 . 7 6 3X 6 X 1 3 . 7 5 1 7 . 5 1 6 . 1 1 4 . 5 1 2 . 8 1 1 . 1 9 . 7 8 . 3 9 7 . 3 3 6 . 4 3 5 . 6 8 5 . 0 5 4 . 5 1 4 . 0 5 3 . 6 6 3 . 3 1 3 . 0 2 2 . 7 6 3X 8 1 8 . 1 3 9 . 3 5 7 . 1 1 5 . 5 6 4 . 4 5 3 . 6 3 3X 8 X 1 8 . 1 3 2 3 . 9 2 3 . 1 2 2 . 1 2 0 . 9 1 9 . 4 1 7 . 9 1 6 . 3 1 4 . 7 1 3 . 3 1 1 . 9 1 0 . 8 9 . 7 8 . 8 2 8 . 0 1 7 . 3 1 6 . 6 8 6 . 1 3 4X 4 1 2 . 2 5 1 0 . 9 8 . 6 8 6 . 9 6 5 . 6 6 4 . 6 7 3 . 9 0 3 . 3 1 2 . 8 4 2 . 4 6 4X 6 1 9 . 2 5 1 6 . 8 1 3 . 5 1 0 . 9 8 . 8 5 7 . 3 1 6 . 1 2 5 . 1 9 4 . 4 6 3 . 8 6 4X 6 X 1 9 . 2 5 2 4 . 5 2 2 . 5 2 0 . 3 1 7 . 9 1 5 . 6 1 3 . 5 1 1 . 7 1 0 . 3 9 . 0 1 7 . 9 6 7 . 0 7 6 . 3 1 5 . 6 7 5 . 1 2 4 . 6 4 4 . 2 3 3 . 8 6 4X 8 2 5 . 3 8 2 1 . 8 1 7 . 6 1 4 . 2 1 1 . 6 9 . 6 8 . 0 4 6 . 8 3 5 . 8 6 5 . 0 8 4X 8 X 2 5 . 3 8 3 3 . 5 3 2 . 4 3 0 . 9 2 9 . 2 2 7 . 2 2 5 . 0 2 2 . 8 2 0 . 6 1 8 . 6 1 6 . 7 1 5 . 1 1 3 . 6 1 2 . 3 1 1 . 2 1 0 . 2 9 . 4 8 . 5 9 6X 6 3 0 . 2 5 2 7 . 6 2 6 . 3 2 4 . 8 2 3 . 0 2 0 . 9 1 8 . 8 1 6 . 8 1 5 . 0 1 3 . 3 1 1 . 9 1 0 . 7 9 . 5 9 8 . 6 6 7 . 8 4 7 . 1 3 6 . 5 1 5 . 9 7 6X 8 4 1 . 2 5 3 7 . 6 3 5 . 9 3 3 . 8 3 1 . 3 2 8 . 5 2 5 . 7 2 2 . 9 2 0 . 4 1 8 . 2 1 6 . 2 1 4 . 6 1 3 . 1 1 1 . 8 1 0 . 7 9 . 7 8 . 9 8 . 1 6X 8 X 4 1 . 2 5 3 9 . 3 3 8 . 5 3 7 . 5 3 6 . 2 3 4 . 7 3 3 . 0 3 1 . 0 2 8 . 9 2 6 . 8 2 4 . 6 2 2 . 6 2 0 . 7 1 8 . 9 1 7 . 4 1 5 . 9 1 4 . 7 1 3 . 5 6X 1 0 5 2 . 2 5 4 4 . 4 4 2 . 7 4 0 . 4 3 7 . 7 3 4 . 7 3 1 . 5 2 8 . 3 2 5 . 4 2 2 . 7 2 0 . 3 1 8 . 2 1 6 . 4 1 4 . 8 1 3 . 5 1 2 . 3 1 1 . 2 1 0 . 3 6X 1 0 X 5 2 . 2 5 4 7 . 2 4 6 . 7 4 6 . 2 4 5 . 5 4 4 . 7 4 3 . 8 4 2 . 8 4 1 . 5 4 0 . 2 3 8 . 6 3 7 . 0 3 5 . 2 3 3 . 3 3 1 . 5 2 9 . 6 2 7 . 8 2 6 . 1 8X 8 5 6 . 2 5 5 3 . 8 5 2 . 8 5 1 . 5 5 0 . 0 4 8 . 1 4 5 . 9 4 3 . 4 4 0 . 7 3 7 . 9 3 5 . 0 3 2 . 3 2 9 . 6 2 7 . 2 2 5 . 0 2 3 . 0 2 1 . 2 1 9 . 6 X I N D I C A T E S B R A C E D I N W E A K D I R E C T I O N ALL V A L U E S B A S E D O N D O U G L A S F I R - L A R C H No.1GRADEConstNo. 2 No.2 No. 2 ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 PO S T A R E A A L L O W A B L E L O A D ( K I P S ) - U N S U P P O R T E D H E I G H T I N F T ( L O A D T A B L E 12 5 % ) SI Z E IN 2 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2X 4 5 . 2 5 1 . 0 1 2X 4 X 5 . 2 5 4 . 8 3 3 . 7 3 2 . 9 4 2 . 3 6 1 . 9 3 1 . 6 1 1 . 3 6 1 . 1 7 1 . 0 1 2X 4 5 . 2 5 1 . 0 6 2X 4 X 5 . 2 5 4 . 9 7 3 . 8 7 3 . 0 6 2 . 4 7 2 . 0 3 1 . 6 9 1 . 4 3 1 . 2 3 1 . 0 6 2X 6 8 . 2 5 1 . 6 7 2X 6 X 8 . 2 5 1 2 . 4 0 1 1 . 0 8 9 . 6 4 8 . 2 6 7 . 0 6 6 . 0 4 5 . 2 0 4 . 5 1 3 . 9 4 3 . 4 7 3 . 0 7 2 . 7 4 2 . 4 6 2 . 2 1 2 . 0 1 1 . 8 2 1 . 6 7 2X 8 1 0 . 8 8 2 . 1 9 2X 8 X 1 0 . 8 8 1 7 . 5 1 6 . 7 1 5 . 7 1 4 . 5 1 3 . 2 1 1 . 9 1 0 . 6 9 . 4 8 . 3 7 7 . 4 7 6 . 6 9 6 . 0 1 5 . 4 2 4 . 9 1 4 . 4 6 4 . 0 7 3 . 7 3 3X 4 8 . 7 5 4 . 6 7 3 . 5 1 2 . 7 2 2 . 1 7 1 . 7 7 3X 4 X 8 . 7 5 8 . 2 8 6 . 4 5 5 . 1 1 4 . 1 2 3 . 3 8 2 . 8 2 2 . 3 9 2 . 0 4 1 . 7 7 3X 6 1 3 . 7 5 7 . 3 2 5 . 5 0 4 . 2 7 3 . 4 1 2 . 7 8 3X 6 X 1 3 . 7 5 2 0 . 7 1 8 . 5 1 6 . 1 1 3 . 8 1 1 . 8 1 0 . 1 8 . 6 7 7 . 5 2 6 . 5 7 5 . 7 8 5 . 1 2 4 . 5 7 4 . 0 9 3 . 6 9 3 . 3 4 3 . 0 4 2 . 7 8 3X 8 1 8 . 1 3 9 . 6 0 7 . 2 4 5 . 6 2 4 . 4 9 3 . 6 6 3X 8 X 1 8 . 1 3 2 9 . 2 2 7 . 9 2 6 . 2 2 4 . 2 2 2 . 0 1 9 . 8 1 7 . 6 1 5 . 7 1 4 . 0 1 2 . 4 1 1 . 1 1 0 . 0 9 . 0 3 8 . 1 8 7 . 4 4 6 . 7 9 6 . 2 2 4X 4 1 2 . 2 5 1 1 . 6 9 . 0 3 7 . 1 5 5 . 7 6 4 . 7 3 3 . 9 5 3 . 3 4 2 . 8 6 2 . 4 8 4X 6 1 9 . 2 5 1 8 . 0 1 4 . 1 1 1 . 2 9 . 0 3 7 . 4 2 6 . 1 9 5 . 2 4 4 . 4 9 3 . 8 9 4X 6 X 1 9 . 2 5 2 8 . 9 2 5 . 8 2 2 . 5 1 9 . 3 1 6 . 5 1 4 . 1 1 2 . 1 1 0 . 5 9 . 2 0 8 . 0 9 7 . 1 7 6 . 3 9 5 . 7 3 5 . 1 7 4 . 6 8 4 . 2 6 3 . 8 9 4X 8 2 5 . 3 8 2 3 . 5 1 8 . 4 1 4 . 7 1 1 . 9 9 . 8 8 . 1 5 6 . 9 0 5 . 9 1 5 . 1 2 4X 8 X 2 5 . 3 8 4 0 . 9 3 9 . 0 3 6 . 7 3 3 . 9 3 0 . 8 2 7 . 7 2 4 . 7 2 1 . 9 1 9 . 5 1 7 . 4 1 5 . 6 1 4 . 0 1 2 . 6 1 1 . 5 1 0 . 4 9 . 5 8 . 7 1 6X 6 3 0 . 2 5 3 3 . 4 3 1 . 4 2 8 . 8 2 6 . 0 2 3 . 1 2 0 . 3 1 7 . 8 1 5 . 7 1 3 . 9 1 2 . 3 1 0 . 9 9 . 8 0 8 . 8 1 7 . 9 7 7 . 2 3 6 . 5 9 6 . 0 3 6X 8 4 1 . 2 5 4 5 . 6 4 2 . 8 3 9 . 3 3 5 . 4 3 1 . 5 2 7 . 7 2 4 . 3 2 1 . 4 1 8 . 9 1 6 . 7 1 4 . 9 1 3 . 4 1 2 . 0 1 0 . 9 9 . 9 9 . 0 8 . 2 6X 8 X 4 1 . 2 5 4 8 . 5 4 7 . 1 4 5 . 4 4 3 . 3 4 0 . 8 3 8 . 0 3 5 . 0 3 2 . 0 2 9 . 1 2 6 . 4 2 3 . 9 2 1 . 7 1 9 . 7 1 8 . 0 1 6 . 4 1 5 . 0 1 3 . 8 6X 1 0 5 2 . 2 5 5 4 . 0 5 1 . 1 4 7 . 4 4 3 . 1 3 8 . 6 3 4 . 3 3 0 . 3 2 6 . 7 2 3 . 7 2 1 . 0 1 8 . 8 1 6 . 8 1 5 . 1 1 3 . 7 1 2 . 4 1 1 . 3 1 0 . 4 6X 1 0 X 5 2 . 2 5 5 8 . 6 5 7 . 8 5 6 . 9 5 5 . 9 5 4 . 6 5 3 . 0 5 1 . 2 4 9 . 2 4 6 . 9 4 4 . 5 4 1 . 9 3 9 . 3 3 6 . 8 3 4 . 3 3 1 . 9 2 9 . 7 2 7 . 6 8X 8 5 6 . 2 5 6 6 . 4 6 4 . 7 6 2 . 6 6 0 . 0 5 6 . 8 5 3 . 3 4 9 . 4 4 5 . 4 4 1 . 5 3 7 . 8 3 4 . 4 3 1 . 2 2 8 . 5 2 6 . 0 2 3 . 8 2 1 . 8 2 0 . 0 X I N D I C A T E S B R A C E D I N W E A K D I R E C T I O N LL V A L U E S B A S E D O N D O U G L A S F I R - L A R C H No.1GRADEConstNo. 2 No.2 No. 2 ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 PO S T A R E A A L L O W A B L E L O A D ( K I P S ) - U N S U P P O R T E D H E I G H T I N F T ( L O A D T A B L E 16 0 % ) SI Z E IN 2 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2X 4 5 . 2 5 1 . 0 1 2X 4 X 5 . 2 5 5 . 0 3 3 . 8 3 2 . 9 9 2 . 3 9 1 . 9 5 1 . 6 3 1 . 3 7 1 . 1 7 1 . 0 1 2X 4 5 . 2 5 1 . 0 7 2X 4 X 5 . 2 5 5 . 2 2 3 . 9 9 3 . 1 3 2 . 5 1 2 . 0 5 1 . 7 1 1 . 4 4 1 . 2 3 1 . 0 7 2X 6 8 . 2 5 1 . 6 8 2X 6 X 8 . 2 5 1 4 . 5 6 1 2 . 4 8 1 0 . 4 9 8 . 7 8 7 . 3 7 6 . 2 4 5 . 3 4 4 . 6 1 4 . 0 1 3 . 5 2 3 . 1 1 2 . 7 7 2 . 4 8 2 . 2 3 2 . 0 2 1 . 8 4 1 . 6 8 2X 8 1 0 . 8 8 2 . 2 1 2X 8 X 1 0 . 8 8 2 1 . 6 2 0 . 2 1 8 . 5 1 6 . 6 1 4 . 7 1 2 . 9 1 1 . 3 9 . 9 8 . 7 1 7 . 7 1 6 . 8 7 6 . 1 4 5 . 5 3 4 . 9 9 4 . 5 3 4 . 1 3 3 . 7 8 3X 4 8 . 7 5 4 . 7 6 3 . 5 6 2 . 7 5 2 . 1 9 1 . 7 8 3X 4 X 8 . 7 5 8 . 7 0 6 . 6 6 5 . 2 2 4 . 1 8 3 . 4 2 2 . 8 5 2 . 4 0 2 . 0 6 1 . 7 8 3X 6 1 3 . 7 5 7 . 4 6 5 . 5 8 4 . 3 1 3 . 4 3 2 . 7 9 3X 6 X 1 3 . 7 5 2 4 . 3 2 0 . 8 1 7 . 5 1 4 . 6 1 2 . 3 1 0 . 4 8 . 9 0 7 . 6 8 6 . 6 8 5 . 8 6 5 . 1 8 4 . 6 1 4 . 1 3 3 . 7 2 3 . 3 7 3 . 0 6 2 . 7 9 3X 8 1 8 . 1 3 9 . 8 1 7 . 3 4 5 . 6 8 4 . 5 2 3 . 6 8 3X 8 X 1 8 . 1 3 3 6 . 1 3 3 . 7 3 0 . 8 2 7 . 6 2 4 . 4 2 1 . 4 1 8 . 8 1 6 . 5 1 4 . 5 1 2 . 9 1 1 . 4 1 0 . 2 9 . 2 1 8 . 3 2 7 . 5 5 6 . 8 8 6 . 2 9 4X 4 1 2 . 2 5 1 2 . 2 9 . 3 2 7 . 3 0 5 . 8 5 4 . 7 9 3 . 9 9 3 . 3 7 2 . 8 8 2 . 4 9 4X 6 1 9 . 2 5 1 9 . 0 1 4 . 6 1 1 . 4 9 . 1 8 7 . 5 1 6 . 2 5 5 . 2 8 4 . 5 2 3 . 9 1 4X 6 X 1 9 . 2 5 3 4 . 0 2 9 . 1 2 4 . 5 2 0 . 5 1 7 . 2 1 4 . 6 1 2 . 5 1 0 . 7 9 . 3 6 8 . 2 1 7 . 2 6 6 . 4 6 5 . 7 8 5 . 2 1 4 . 7 1 4 . 2 8 3 . 9 1 4X 8 2 5 . 3 8 2 4 . 8 1 9 . 1 1 5 . 0 1 2 . 1 9 . 9 8 . 2 3 6 . 9 6 5 . 9 5 5 . 1 5 4X 8 X 2 5 . 3 8 5 0 . 5 4 7 . 2 4 3 . 2 3 8 . 7 3 4 . 2 3 0 . 0 2 6 . 3 2 3 . 1 2 0 . 3 1 8 . 0 1 6 . 0 1 4 . 3 1 2 . 9 1 1 . 6 1 0 . 6 9 . 6 8 . 8 1 6X 6 3 0 . 2 5 4 0 . 7 3 7 . 2 3 3 . 1 2 8 . 9 2 5 . 0 2 1 . 6 1 8 . 7 1 6 . 3 1 4 . 3 1 2 . 6 1 1 . 2 9 . 9 7 8 . 9 5 8 . 0 7 7 . 3 1 6 . 6 6 6 . 0 8 6X 8 4 1 . 2 5 5 5 . 6 5 0 . 7 4 5 . 1 3 9 . 4 3 4 . 1 2 9 . 4 2 5 . 5 2 2 . 2 1 9 . 5 1 7 . 2 1 5 . 2 1 3 . 6 1 2 . 2 1 1 . 0 1 0 . 0 9 . 1 8 . 3 6X 8 X 4 1 . 2 5 6 0 . 7 5 8 . 3 5 5 . 3 5 1 . 6 4 7 . 5 4 3 . 1 3 8 . 8 3 4 . 7 3 1 . 1 2 7 . 8 2 5 . 0 2 2 . 5 2 0 . 3 1 8 . 5 1 6 . 8 1 5 . 3 1 4 . 1 6X 1 0 5 2 . 2 5 6 6 . 2 6 1 . 0 5 4 . 9 4 8 . 4 4 2 . 2 3 6 . 6 3 1 . 9 2 7 . 8 2 4 . 4 2 1 . 6 1 9 . 2 1 7 . 1 1 5 . 4 1 3 . 9 1 2 . 6 1 1 . 5 1 0 . 5 6X 1 0 X 5 2 . 2 5 7 4 . 3 7 3 . 0 7 1 . 4 6 9 . 5 6 7 . 2 6 4 . 5 6 1 . 3 5 7 . 9 5 4 . 2 5 0 . 5 4 6 . 7 4 3 . 1 3 9 . 8 3 6 . 6 3 3 . 8 3 1 . 2 2 8 . 8 8X 8 5 6 . 2 5 8 3 . 3 8 0 . 3 7 6 . 5 7 2 . 0 6 6 . 7 6 1 . 0 5 5 . 2 4 9 . 7 4 4 . 7 4 0 . 1 3 6 . 1 3 2 . 6 2 9 . 5 2 6 . 8 2 4 . 4 2 2 . 3 2 0 . 4 X I N D I C A T E S B R A C E D I N W E A K D I R E C T I O N ALL V A L U E S B A S E D O N D O U G L A S F I R - L A R C H No.1GRADEConstNo. 2 No.2 No. 2 ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 ROOF LOADS composite shingles 3.0 psf re-roof 3.0 psf 1/2" plywwod 1.5 psf rafters 2x6 at 16"2.0 psf insulation 0.5 psf Ceiling 3.0 psf beams/headers 1.0 psf MP&E/ misc.1.0 psf D= 15.0 psf Lr= 20.0 psf REDUCIBLE FLOOR LOADS flooring 1.0 psf 3/4" plywood 2.3 psf joist 3.0 psf ceiling 4.0 psf beams/headers 2.0 psf MP&E/ misc.2.7 psf D= 15.0 psf L= 40.0 psf EXTERIOR WALL LOADS 7/8" stucco 10.0 psf 1/2" plywood 1.5 psf 2x6 studs at 16"oc 1.5 psf insulation 0.5 psf 1/2" gyp board 2.3 psf MP&E/ misc.0.2 psf D= 16.0 psf INTERIOR WALL LOADS 1/2" gyp board 2.3 psf 1/2" plywood 1.5 psf 2x6 studs at 16"oc 1.5 psf insulation 0.5 psf 1/2" gyp board 2.3 psf MP&E/ misc.1.9 psf D= 10.0 psf A-DESIGN LOADS-comp. shingles ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 2x4 TA= 450 x 1.60 x 1.5 x 3.5 =kips 2x6 TA= 575 x 1.60 x 1.5 x 5.5 =kips 3x4 TA= 575 x 1.60 x 2.5 x 3.5 =kips 3x6 TA= 575 x 1.60 x 2.5 x 5.5 = kips TYPE 2x4 6 TA= 141 x 1.60 x x 6 = 1.25 kips 1.5FT 2x4 8 TA= 141 x 1.60 x x 8 = 1.67 kips 2FT 2x4 10 TA= 141 x 1.60 x x 10 = 2.09 kips 2.5FT 2x4 12 TA= 141 x 1.60 x x 12 = 2.51 kips 3FT 2x4 14 TA= 141 x 1.60 x x 14 = 2.92 kips 3.5FT 2x4 16 TA= 141 x 1.60 x x 16 = 3.34 kips 4FT 2x4 18 TA= 141 x 1.60 x x 18 = 3.76 kips 4.5FT 2x6 20 TA= 141 x 1.60 x x 20 = 4.18 kips 5FT 2x6 22 TA= 141 x 1.60 x x 22 = 4.60 kips 5.5FT 2x6 24 TA= 141 x 1.60 x x 24 = 5.01 kips 6FT 2x6 B1 TA= 604 x 1.60 x x 6 = 5.80 kips 0.99 2x6 B2 TA= 604 x 1.60 x x 8 = 7.73 kips 1.09 3x6 B3 TA= 725 x 1.60 x x 8 = 9.28 kips 1.09 3x6 B4 TA=1208 x 1.60 x x 6 = 11.60 kips 1.19 3x6 B5 TA=1208 x 1.60 x x 8 = 15.46 kips 1.31 SPLICE LENGTH 0.93 DOUBLE TOP PLATE SPLICE 3.78 7.59 0.93 0.93 8.05 12.65 0.93 0.93 0.93 0.93 0.93 1.00 0.93 0.93 1.00 1.00 1.00 1.00 ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 ROOF JOIST Tag:RJ-1 L= 8.00 ft Uniform Loads D (psf)L (psf)s (in)W (plf) 15 20 16 47 Shear:Vmax <Vallow OK 0.19 K 1.24 K Flexure:Mmax <Mallow OK 0.37 k-ft 1.06 k-ft USE:16" O.C. Deflection:Δ =0.13 in = L/743 OK 2x6 RAFTERS @ 1401 S Rosewood Ave Unit# 2& 34/22/2025 Tag:B1 Member: L = 15.50 ft No. Members: 1 L = 15.50 ft 7.15 kips 7.15 kips A = 56.00 in² S = 149.33 in³Shear and Moment Diagrams I = 1194.67 in⁴ E = 2,000,000 psi Va =10.83 kips Ma =34.95 k-ft CD = 1.00 CF = 1.00 CV = 0.97 Cr = 1.00 Mmáx = 27.69 k-ft Total Load L/n= 240 Vmáx = 7.15 kips Live Load L/n= 360 Uniform Loads Shear: D (psf) L (psf) Trib. (ft) W Vmáx =7.15 kips 15 20 22.00 770 Vallow =10.83 kips 66% 15 40 OK 15 60 16 9.50 152 Flexure: Mmáx =27.69 k-ft Σw =0.922 klf Mallow =33.86 k-ft 82% OK Point Loads (P1)x1 = 0.00 ft D (psf) L (psf) Trib. 1 (ft) Trib. 2 (ft) W Deflection: D(D+L) =0.50 in 65% L < L 371 240 Σw =0.000 kips OK Point Loads (P2)x2 = 0.00 ft D(L ONLY) =0.24 in 46% D (psf) L (psf) Trib. 1 (ft) Trib. 2 (ft) W L < L 778 360 OK Σw =0.000 kips USE: 1- 3.5X16 PSL 3.5x16 PSL 𝐷=𝐷+𝐷+𝐷+𝐷 1401 S Rosewood Ave Unit# 2& 34/22/2025 HEADERS Tag:H1 L = 4.00 ft Uniform Loads D (psf) L (psf) Trib. (ft) W 73%Shear:Vmax <Vallow Roof 15 20 30.00 1050 OK 2.10 K 2.89 K Floor Wall 98%Flexure:Mmax <Mallow Σw =1.050 klf OK 2.10 k-ft 2.15 k-ft 39%Deflection:Δ =0.08 in = L/616 USE:OK4x6 𝑉=𝑊𝐿 2 𝑀=𝑊𝐿 8 1401 S Rosewood Ave Unit# 2& 34/22/2025 1401 S Rosewood Ave Unit# 2& 34/22/2025 CONTINUOUS FOOTINGS Tag:CF-1 Uniform Loads D (psf) L (psf) Trib. (ft) W ROOF 15 20 30.00 1050 DECK FLOOR WALL 16 9.50 152 Σw =1202.00 plf USE: B = 1202 plf = 0.80 ft 1500 plf 1'-0" WIDE FTG. 1401 S Rosewood Ave Unit# 2& 34/22/2025 FOOTING CAPACITY Tag:(N) CF-1 H1=24 in qa=1500 psf H2=8 in L= 67.50 in D= 4 in 5.63 ft W= 12 in A= 810 in² 5.63 ft² Uniform Loads D (psf) L (psf) Trib. (ft) W Roof 15 20 30.00 1050 Deck Floor Wall 16 9.50 152 Σw =1202.00 plf Conc. Wt. = 100 plf Abv. Grade Wuniforme=1302 plf Pa=8.44 kips Pload=7.32 kips Pnet=1.11 kips Pnet =1.11 kips     1401 S Rosewood Ave Unit# 2& 34/22/2025 FOOTING CAPACITY Tag:(E) CF-1 H1=24 in qa=1500 psf H2=8 in L= 67.50 in D= 4 in 5.63 ft W= 12 in A= 810 in² 5.63 ft² Uniform Loads D (psf) L (psf) Trib. (ft) W Roof 15 20 30.00 1050 Deck Floor Wall 16 9.50 152 Σw =1202.00 plf Conc. Wt. = 100 plf Abv. Grade Wuniforme=1302 plf Pa=8.44 kips Pload=7.32 kips Pnet=1.11 kips Pnet =1.11 kips     1401 S Rosewood Ave Unit# 2& 34/22/2025 CONTINUOUS FOOTINGS Tag:(E) CF-1 Uniform Loads D (psf) L (psf) Trib. (ft) W ROOF 15 20 30.00 1050 DECK FLOOR WALL 16 9.50 152 Σw =1202.00 plf USE: B = 1202 plf = 0.80 ft 1500 plf 1'-0" WIDE FTG. 1401 S Rosewood Ave Unit# 2& 34/22/2025 ASCE Hazards Report Address: 1401S S Rosewood Ave Santa Ana, California 92707 Standard:ASCE/SEI 7-22 Latitude:33.728941 Risk Category:II Longitude:-117.881771 Soil Class:Default Elevation:65.44107110986225 ft (NAVD 88) Page 1 of 4https://ascehazardtool.org/Tue Apr 09 2024 1401 S Rosewood Ave Unit# 2& 34/22/2025 PGA M : 0.66 SMS : 1.74 SM1 : 1.2 SDS : 1.16 SD1 : 0.8 T L : 8 SS : 1.48 S1 : 0.53 VS30 : 260 Seismic Design Category:D Multi-Period Design Spectrum S (g) vs T(s)a Multi-Period MCE SpectrumR S (g) vs T(s)a Two-Period Design Spectrum S (g) vs T(s)a Two-Period MCE SpectrumR S (g) vs T(s)a Design Vertical Response Spectrum Vertical ground motion data has not yet been made available by USGS. MCE Vertical Response SpectrumR Vertical ground motion data has not yet been made available by USGS. Seismic DefaultSite Soil Class: Results: Page 2 of 4https://ascehazardtool.org/Tue Apr 09 2024 1401 S Rosewood Ave Unit# 2& 34/22/2025 INPUT DATA B I = 1.00 Category II V = 110.00 mph Kzt = 1.00 Flat he = 9.50 ft hr = 15.50 ft L = 55.50 ft B = 33.50 ft A = 10.00 ft2 DESIGN SUMMARY Max horizontal force normal to building length, L, face = 8.60 kips X 0.6=5.16 kips (ASD)=2.78psf Max horizontal force normal to building length, B, face = 5.79 kips X 0.6=3.47 kips (ASD)=1.87psf Max total horizontal torsional load = 57 ft-kips Max total upward force = 27.40 kips ANALYSIS Velocity pressure qh = 0.00256 Kh Kzt Kd V2 I =18.43 psf where: qh = velocity pressure at mean roof height, h. Kh = velocity pressure exposure coefficient evaluated at height, h,= 0.70 Kd = wind directionality factor = 0.85 h = mean roof height = 12.50 ft < 60 ft, [Satisfactory] Design pressures for MWFRS p = qh [(G Cpf )-(G Cpi )] where: p = pressure in appropriate zone G Cp f = product of gust effect factor and external pressure coefficient G Cp i = product of gust effect factor and internal pressure coefficient = 0.18 or -0.18 a = width of edge strips, MAX[ MIN(0.1B, 0.4h), 0.04B,3] =3.35 ft Net Pressures (psf), Basic Load Cases 19.71 0.00 (+GCp i ) (-GCp i ) (+GCp i ) (-GCp i ) 1 0.53 6.40 13.04 0.40 4.05 10.69 2 -0.69 -16.03 -9.40 -0.69 -16.03 -9.40 3 -0.48 -12.12 -5.49 -0.37 -10.14 -3.50 4 -0.43 -11.19 -4.56 -0.29 -8.66 -2.03 1E 0.80 11.36 17.99 0.61 7.93 14.56 2E -1.07 -23.04 -16.40 -1.07 -23.04 -16.40 3E -0.69 -15.98 -9.34 -0.53 -13.09 -6.45 4E -0.64 -15.04 -8.40 -0.43 -11.24 -4.61 5 -0.45 -11.61 -4.98 -0.45 -11.61 -4.98 6 -0.45 -11.61 -4.98 -0.45 -11.61 -4.98 Net Pressures (psf), Torsional Load Cases 19.71 (+GCp i ) (-GCp i ) 1T 0.53 1.60 3.26 2T -0.69 -4.01 -2.35 3T -0.48 -3.03 -1.37 4T -0.43 -2.80 -1.14 0.00 (+GCp i ) (-GCp i ) 1T 0.40 1.01 2.67 2T -0.69 -4.01 -2.35 3T -0.37 -2.53 -0.88 4T -0.29 -2.17 -0.51 G Cp f Surface WIND ANALYSIS FOR LOW-RISE BUILDING ( BASED ON ASE 7-16/ IBC 2021/ CBC 2022) Roof angle q = Surface Net Pressure withG Cp f Importance factor Building length Building height to ridge Building height to eave Topographic factor Basic wind speed Roof angle q = G Cp f Net Pressure with Effective area of components Exposure category (B, C or D) Roof angle q = Building width Net Pressure with Surface Roof angle q = G Cp f Net Pressure with 1401 S Rosewood Ave Unit# 2& 34/22/2025 Basic Load Cases in Transverse Direction Basic Load Cases in Longitudinal Direction Area Area (ft2)(+GCp i ) (-GCp i )(ft2)(+GCp i ) (-GCp i ) 1 464 2.97 6.04 1 347 1.41 3.71 2 868 -13.92 -8.16 2 790 -12.67 -7.43 3 868 -10.53 -4.77 3 790 -8.01 -2.77 4 464 -5.19 -2.11 4 347 -3.01 -0.70 1E 64 0.72 1.15 1E 72 0.57 1.04 2E 119 -2.75 -1.96 2E 197 -4.55 -3.24 3E 119 -1.90 -1.11 3E 197 -2.58 -1.27 4E 64 -0.96 -0.53 4E 72 -0.81 -0.33 Horiz. 8.41 8.41 Horiz. 5.79 5.79 Vert. -27.40 -15.06 Vert. -26.18 -13.84 10 psf min.Horiz. 8.60 8.60 10 psf min.Horiz. 4.19 4.19 Sec. 6.1.4.1 Vert. -18.59 -18.59 Sec. 6.1.4.1 Vert. -18.59 -18.59 Torsional Load Cases in Transverse Direction Torsional Load Cases in Longitudinal Direction Area Area (ft2)(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )(ft2)(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i ) 1 200 1.28 2.61 16 32 1 138 0.56 1.47 3 7 2 375 -6.01 -3.52 -25 -14 2 592 -9.50 -5.57 44 26 3 375 -4.54 -2.06 19 8 3 592 -6.01 -2.07 -28 -10 4 200 -2.24 -0.91 27 11 4 138 -1.19 -0.28 6 1 1E 64 0.72 1.15 18 28 1E 72 0.57 1.04 8 14 2E 119 -2.75 -1.96 -23 -16 2E 197 -4.55 -3.24 21 15 3E 119 -1.90 -1.11 16 9 3E 197 -2.58 -1.27 -12 -6 4E 64 -0.96 -0.53 23 13 4E 72 -0.81 -0.33 11 4 1T 264 0.42 0.86 -6 -12 1T 209 0.21 0.56 -2 -4 2T 494 -1.98 -1.16 9 5 2T 790 -3.17 -1.86 -30 -17 3T 494 -1.50 -0.68 -7 -3 3T 790 -2.00 -0.69 19 6 4T 264 -0.74 -0.30 -10 -4 4T 209 -0.45 -0.11 -3 -1 57 57 36.2 36.2 Design pressures for components and cladding p = qh[ (G Cp) - (G Cpi)] where: p = pressure on component pmin = 10 psf (Sec. 6.1.4.2, pg 21) G Cp = external pressure coefficient. see table below Effective Area (ft2) GCP - GCP GCP - GCP GCP - GCP GCP - GCP GCP - GCP Comp.10 0.50 -0.90 0.50 -1.70 0.50 -2.60 1.00 -1.10 1.00 -1.40 Positive Negative Positive Negative Positive Negative Positive Negative Positive Negative 12.53 -19.91 12.53 -34.65 12.53 -51.24 21.75 -23.59 21.75 -29.12 Surface Pressure (k) with Zone 1 Zone 2 Total Horiz. Torsional Load, MT Comp. & Cladding Zone 1 Zone 2 Surface Pressure ( psf ) Torsion (ft-k) S Surface Pressure (k) withPressure (k) with S Torsion (ft-k) Total Horiz. Torsional Load, MT Zone 5 Zone 3 Zone 4 Zone 5 Zone 3 Zone 4 Pressure (k) withSurface 1401 S Rosewood Ave Unit# 2& 34/22/2025 SEISMIC BASE SHEAR (ASCE7-22) Latitude: 33.728941 Longitude: -117.881771 SITE CLASS:D (Table 20.3-1) ρ=1.3 R=6.5 (Table 12.2-1)Ie=1 (Section 21.4) 1.740 0 2.100 0 (11.4-3) 1.160 (11.4-4) 1.4 0.24137931 1.20689655 See on Figs. 22-14 through 22-17 0.02 9.500 0.75 0.108 W= Effective seismeic weight (GOVERNS) For S1 is equal to greater than 0.6g 0.162 W 1.990 W 0.178 0.232 W Strength Level 0.162 W Allowable Stress Design 𝑆= 𝑆= 𝑆=2 3 𝑆 𝑆= 𝑆=2 3 𝑆 𝑆= 𝑇= 𝐶ℎ 𝐶= ℎ= 𝑥= 𝑇= 𝑉=𝐶𝑊 𝑉=0.01𝑊 𝑉=W 𝑉=ρW 𝑉= 𝑉= 𝐶== 𝑉=𝐶𝜌𝑊= 𝑉=0.7𝑉= 𝑇= 𝑇= 𝑇= 1401 S Rosewood Ave Unit# 2& 34/22/2025 SEISMIC ANALYSIS WEIGHT Level 1 W roof = 20 psf x 1343 ft^2 =26.87 kips W wall = 16 psf x 768 ft^2 =12.28 kips WR = 39.15 kips BASE SHEAR 0.162 x 39.15 kips = 6.36 kips F1= DISTRIBUTION OF BASE SHEAR 1 Level 2 or more levels W TOTAL 39.15 kips 4.733 psf 𝑽𝑩𝑨𝑺𝑬= 𝑽 ∗ 𝑾𝑻𝑶𝑻𝑨𝑳 𝑉= 𝑉 ∗ 𝑊= 𝑭𝒙= 𝑽𝑩𝑨𝑺𝑬∗𝑾𝑿∗ 𝒉𝑻𝑶𝑻𝑨𝑳 𝑾𝟏∗ 𝒉𝟏+𝑾𝟐∗𝒉𝟏+ 𝒉𝟐+ ⋯𝑾𝒏∗ 𝒉𝑻𝑶𝑻𝑨𝑳 𝑽𝑩𝑨𝑺𝑬=𝑽∗𝑾𝑻𝑶𝑻𝑨𝑳 𝑨 1401 S Rosewood Ave Unit# 2& 34/22/2025 1401 S Rosewood Ave Unit# 2& 34/22/2025 F1= 4.730 psf SW U-FORCE T.A. FORCE L1 L2 L3 L4 X1 4.73 73.30 0.35 KIPS 4.50 ft X2 4.73 617.60 2.92 KIPS 19.00 ft X3 4.73 617.60 2.92 KIPS 4.25 ft 5.83 ft Y1 4.73 854.15 4.04 KIPS 12.00 ft Y2 4.73 648.18 3.07 KIPS 8.00 ft Y3 4.73 369.00 1.75 KIPS 14.25 ft FORCES LEVEL 1 LENGHT WALLS 1401 S Rosewood Ave Unit# 2& 34/22/2025 DATA: SEISMIC GOVERNS Load Comb.:(0.6-.14SDS) D + 0.7 E SDS=1.16 TAG: FORCE HEIGHT X1.1 F1=0.35 kips h1=9.50 ft L= 4.50 ft 4.50 ft 0.35 kips 9.50 ft SHEAR STRESS 347 lbs 4.50 ft OVERTURNING WALL:X1.1 4.50 ft LEVEL 1 MOT 3.29 3.29 k-ft Uniform Loads Load Unit Load Tributary W (psf) (ft) (plf) ROOF 15 16.50 248 WALL 16 9.50 152 Σw =400 plf USE: DLR=0.44 TYPE:SHEARWALL h/w=2.11 1.25-0.125h/b=0.99 Vallow=335 PLF OK ST-1 USE: HDU2 4 x Tallow=3.08 kips OK ST-1 w/HDU2 H.D. S/LTT20 77 plf SHEARWALL CALCULATIONS LEVEL 1 6 4.04 k-ft 4 POST 0.34 kips 𝐿=𝐹=ℎ= 𝑣=𝐹∗ 1000 𝐿== 𝑀𝑂𝑇=𝐹∗𝐿 𝐿∗ ℎ 𝐿= 𝑀𝑅=(𝛴𝑤∗ (𝐿)) 2 = 𝑇=𝑀𝑂𝑇− (𝐷𝐿𝑅∗𝑀𝑅) 𝐿= 1401 S Rosewood Ave Unit# 2& 34/22/2025 DATA: SEISMIC GOVERNS Load Comb.:(0.6-.14SDS) D + 0.7 E SDS=1.16 TAG: FORCE HEIGHT X2.1 F1=2.92 kips h1=9.50 ft L= 19.00 ft 19.00 ft 2.92 kips 9.50 ft SHEAR STRESS 2921 lbs 19.00 ft OVERTURNING WALL:X2.1 19.00 ft LEVEL 1 MOT 27.75 27.75 k-ft Uniform Loads Load Unit Load Tributary W (psf) (ft) (plf) ROOF 15 16.50 248 WALL 16 9.50 152 Σw =400 plf USE: DLR=0.44 TYPE:SHEARWALL h/w=0.50 Vallow=340 PLF OK ST-1 USE: HDU2 4 x Tallow=3.08 kips OK ST-1 w/HDU2 H.D. NO 154 plf SHEARWALL CALCULATIONS LEVEL 1 6 72.11 k-ft 4 POST 0.00 kips 𝐿=𝐹=ℎ= 𝑣=𝐹∗ 1000 𝐿== 𝑀𝑂𝑇=𝐹∗𝐿 𝐿∗ ℎ 𝐿= 𝑀𝑅=(𝛴𝑤∗ (𝐿)) 2 = 𝑇=𝑀𝑂𝑇− (𝐷𝐿𝑅∗𝑀𝑅) 𝐿= 1401 S Rosewood Ave Unit# 2& 34/22/2025 DATA: SEISMIC GOVERNS Load Comb.:(0.6-.14SDS) D + 0.7 E SDS=1.16 TAG: FORCE HEIGHT X3.1 X3.2 F1=2.92 kips h1=9.50 ft L= 4.25 ft L= 5.83 ft 10.08 ft 2.92 kips 9.50 ft SHEAR STRESS 2921 lbs 10.08 ft OVERTURNING WALL:X3.1 4.25 ft LEVEL 1 MOT 11.70 11.70 k-ft Uniform Loads Load Unit Load Tributary W (psf) (ft) (plf) ROOF 15 16.50 248 WALL 16 9.50 152 Σw =400 plf USE: DLR=0.44 TYPE:SHEARWALL h/w=2.24 1.25-0.125h/b=0.97 Vallow=330 PLF OK ST-3 USE: HDU2 4 x Tallow=3.08 kips OK ST-6 w/HDU2 H.D. S/HTT4 290 plf SHEARWALL CALCULATIONS LEVEL 1 6 3.61 k-ft 4 POST 2.38 kips 𝐿=𝐹=ℎ= 𝑣=𝐹∗ 1000 𝐿== 𝑀𝑂𝑇=𝐹∗𝐿 𝐿∗ ℎ 𝐿= 𝑀𝑅=(𝛴𝑤∗ (𝐿)) 2 = 𝑇=𝑀𝑂𝑇− (𝐷𝐿𝑅∗𝑀𝑅) 𝐿= 1401 S Rosewood Ave Unit# 2& 34/22/2025 WALL:X3.2 5.83 ft LEVEL 1 MOT 16.05 16.05 k-ft Uniform Loads Load Unit Load Tributary W (psf) (ft) (plf) ROOF 15 16.50 248 WALL 16 9.50 152 Σw =400 plf USE: TYPE:SHEARWALL h/w=1.63 Vallow=340 PLF OK ST-3 USE: HDU2 4 x Tallow=3.08 kips OK ST-6 w/HDU2 H.D. S/HTT4 6 4 POST 6.79 k-ft 2.24 kips 𝑀𝑂𝑇=𝐹∗𝐿 𝐿∗ ℎ 𝐿= 𝑀𝑅=(𝛴𝑤∗ (𝐿)) 2 = 𝑇=𝑀𝑂𝑇∗ (𝐷𝐿𝑅∗𝑀𝑅) 𝐿= 1401 S Rosewood Ave Unit# 2& 34/22/2025 DATA: SEISMIC GOVERNS Load Comb.:(0.6-.14SDS) D + 0.7 E SDS=1.16 TAG: FORCE HEIGHT Y1.1 F1=4.04 kips h1=9.50 ft L= 12.00 ft 12.00 ft 4.04 kips 9.50 ft SHEAR STRESS 4040 lbs 12.00 ft OVERTURNING WALL:Y1.1 12.00 ft LEVEL 1 MOT 38.38 38.38 k-ft Uniform Loads Load Unit Load Tributary W (psf) (ft) (plf) ROOF 15 1.33 20 WALL 16 9.50 152 Σw =172 plf USE: DLR=0.44 TYPE:SHEARWALL h/w=0.79 Vallow=340 PLF OK ST-4 USE: HDU2 4 x Tallow=3.08 kips OK ST-6 w/HDU2 H.D. S/HTT4 337 plf SHEARWALL CALCULATIONS LEVEL 1 6 12.38 k-ft 4 POST 2.75 kips 𝐿=𝐹=ℎ= 𝑣=𝐹∗ 1000 𝐿== 𝑀𝑂𝑇=𝐹∗𝐿 𝐿∗ ℎ 𝐿= 𝑀𝑅=(𝛴𝑤∗ (𝐿)) 2 = 𝑇=𝑀𝑂𝑇− (𝐷𝐿𝑅∗𝑀𝑅) 𝐿= 1401 S Rosewood Ave Unit# 2& 34/22/2025 DATA: SEISMIC GOVERNS Load Comb.:(0.6-.14SDS) D + 0.7 E SDS=1.16 TAG: FORCE HEIGHT Y2.1 F1=3.07 kips h1=9.50 ft L= 8.00 ft 8.00 ft 3.07 kips 9.50 ft SHEAR STRESS 3066 lbs 8.00 ft OVERTURNING WALL:Y2.1 8.00 ft LEVEL 1 MOT 29.13 29.13 k-ft Uniform Loads Load Unit Load Tributary W (psf) (ft) (plf) ROOF 15 16.50 248 WALL 16 9.50 152 Σw =400 plf USE: DLR=0.44 TYPE:SHEARWALL h/w=1.19 Vallow=510 PLF OK ST-4 USE: HDU2 4 x Tallow=3.08 kips OK ST-6 w/HDU2 H.D. S/HTT4 383 plf SHEARWALL CALCULATIONS LEVEL 1 4 12.78 k-ft 4 POST 2.94 kips 𝐿=𝐹=ℎ= 𝑣=𝐹∗ 1000 𝐿== 𝑀𝑂𝑇=𝐹∗𝐿 𝐿∗ ℎ 𝐿= 𝑀𝑅=(𝛴𝑤∗ (𝐿)) 2 = 𝑇=𝑀𝑂𝑇− (𝐷𝐿𝑅∗𝑀𝑅) 𝐿= 1401 S Rosewood Ave Unit# 2& 34/22/2025 DATA: SEISMIC GOVERNS Load Comb.:(0.6-.14SDS) D + 0.7 E SDS=1.16 TAG: FORCE HEIGHT Y3.1 F1=1.75 kips h1=9.50 ft L= 14.25 ft 14.25 ft 1.75 kips 9.50 ft SHEAR STRESS 1745 lbs 14.25 ft OVERTURNING WALL:Y3.1 14.25 ft LEVEL 1 MOT 16.58 16.58 k-ft Uniform Loads Load Unit Load Tributary W (psf) (ft) (plf) ROOF 15 1.33 20 WALL 16 9.50 152 Σw =172 plf USE: DLR=0.44 TYPE:SHEARWALL h/w=0.67 Vallow=340 PLF OK ST-1 USE: HDU2 4 x Tallow=3.08 kips OK ST-1 w/HDU2 H.D. S/LTT20 122 plf SHEARWALL CALCULATIONS LEVEL 1 6 17.46 k-ft 4 POST 0.63 kips 𝐿=𝐹=ℎ= 𝑣=𝐹∗ 1000 𝐿== 𝑀𝑂𝑇=𝐹∗𝐿 𝐿∗ ℎ 𝐿= 𝑀𝑅=(𝛴𝑤∗ (𝐿)) 2 = 𝑇=𝑀𝑂𝑇− (𝐷𝐿𝑅∗𝑀𝑅) 𝐿= 1401 S Rosewood Ave Unit# 2& 34/22/2025 RFG J A� - lFARWA I SCH SHEARWALL SCHEDULE MARK SHEATHING NAIL EDGE FIELD SILL TO SILL TO ALLOW. SHEAR SIZE NAIL NAIL SHEAR WALL ( 1 ) (2) SPACING SPACING WOOD CONN. (1) CONC. CONN. (1) (PLF) TYPE(3) 15/32 STR I O.S. 10d 6" 12" SDS1/4"x6" @ 16" 2x: 5/8"1/J A.B. @ 32"340 I 3x: 5/8"1/J A.B. @ 48" 15/32 STR I O.S. 10d 4" 12" SDS1/4"x6" @ 12" 3x: 5/8"1/J A.B. @ 32" 510 JI ill 15/32 STR I O.S. 10d 3" STGR( 4) 12" SDS1/4"x6" @ 9" 3x: 5/8"1/J A.B. @ 24" 665 JI In 15/32 STR I O.S. 10d 2" STGR( 4) 12" SDS1/4''x6" @ 6" 3x: 5/8"1/J A.B. @ 16" 870 JI & 15/32 STR I D.S. 10d 4" 12" SDS1/4''x6" @ 6" 3x: 5/8"1/J A.B. @ 16" 1020 III � 15/32 STR I D.S. 10d 3" STGR( 4) 12" SDS1/4''x6" @ 4" 3x: 5/8"1/J A.B. @ 12" 1330 K A 15/32 STR I D.S. 10d 2" STGR( 4) 12" SDS1/4''x6" @ 3" 3x: 5/8"1/J A.B. @ 8" 1740 K SHEARWALL NOTES: (1)0.5. INDICATE5 5HEATI-HNG ON ONE 51DE OF WALL AS 5HOWN ON FLAN5.D.5. INDICATE5 DOU6LE 51DED 5HEARWALL: 5HEATHING ON 60TH 51DE5 OF WALL (2)USE COMMON WIRE NAIL5 FOR ALL STRUCT-1 5HEATHING. ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 REMARKS 4x4 4x4 4X4 4X6 4X67.15 10.83 ALLOWABLE 75% 2.31 3.42 4.23 6X6HDU14 3.075 4.565 5.645 6.970 9.535 14.445 5.23 HDU5 HDU8 HDU11 HOLDOWNS HDU2 HDU4 HD ALLOWABLE UPLIFT ESTRUCTURA USA, INC. ADVANCED STRUCTURAL ENGINEERING 468 North Camden Orive #131E Beverly Hills, CA. 90210 Sheet: Job. No: Project: 1401 S Rosewood Ave Unit# 2& 34/22/2025 STRAP HD SCHEDULE TAG STRAP TYPE END NAILS REO. WITHIN CAPACITY LA CITY LENGTH END LENGTH "L 1" (KIPS) (KIPS) "L1" ST-1 CS18 10" 10 -10d 1.37 1.03 ST-2 CS16 12" 11 -10d 1.705 1.28 ST-3 2-CS18 10" 20 -10d 2.74 2.06 ST-4 2-CS16 12" 22 -10d 3.41 2.56 ST-5 CMSTC16 23" 33 -16d SINKERS 4.59 3.44 ST-6 CMST14 30" 38 -16d 6.49 4.87 ST-7 CMST12 39" 50 -16d 9.22 6.91 I-ID 5TRAP « NAILING FER 5CI-IEDI.ILE 1 I-IOI..DOl+I POST FER PLAN < 4x MINJ i 5TLl6 POST TO MATCI-IA60YE FLOOR FRAMING -------'==-t-- JOl5T OTI-IER DIRECTION <1-11-ERE OCCUR5> _ __,_6EAM FER PLAN 11 lYPICAL STRAP HOLDOWN EQUIVALENT HOLD DOWN @ FOUNDATION HDU2 HDU2 HDU2 HDU4 HDU5 HDU8 HDU11 I-ID 5TRAP « NAILING FER 5CI-IEDULE I-IOLDoi,.¡¡,..¡ POST FER PLAN < 4x MIN.) 5TU6 POST TO MATCI-I AeOYE FLOOR FRAMING JOl5T OTI-IER DIRECTION (1-11-!ERE OCCU!e> -------+--1--I-IOLDoi,.¡¡,..¡ POST FER PLAN <MATCl-l 51ZE « ALIGN w/ AeOYE>5EE NOTE '3 AND EQUIYALENT I-ID TA6LE NOTE: IF END LENGiTI-I 'LI' 15 GREATER TI-IAN 6EAM DEPTI-I, CAREFULLY 6END 5TRAP AROI.ND 60TTa-l Cf 6EAM AND NAIL ACCORDINGL Y. lYPICAL STRAP HOLDOWN _.....-----,-.---I-ID 5TRAP « NAILING FER 5CI-IEDI.ILE I-IOI..DOl+I POST FER PLAN < 4x MINJ lYPICAL STRAP HOLDOWN TO BEAM NOTE: IF END L�TI-I 'LI' 15 GREATER TI-IAN 6EAM DEPTI-I 1401 S Rosewood Ave Unit# 2& 34/22/2025 South Coast Air Quality Management District 21865 Copley Drive, Diamond Bar, CA 91765­4182 Phone: (909) 396­2336 www.aqmd.gov Facility ID 206804 Notification Number 830656 Rule 1403 Notification of Routine Demolition Please maintain a copy of this Notification at the job site, either electronic or paper. Project Type Project Type Demolition Project Urgency Routine Origin Date 3/13/2025 9:34:43 AM Completed By Pablo Morales Phone Number (949) 942­3202 User Email moralespab22@gmail.com Contractor Information Company Name P&P MORALES CONSTRUCTION INC Address 27702 CROWN VALLEY PKY City LADERA RANCH State CA Zip 92694 CSLB License #1091352 OSHA REG # Supervisor #1 Pablo Morales Phone (949) 942­3202 Site Information Site Name HernandezDemo Project #Rosewood Site Street #1401 S Street Name ROSEWOOD AVE Cross Street EDINGER Site County ORANGE City SANTA ANA State CA Zip 92707 Contact Name Pablo Morales Contact Phone (949)942­3202 Site Owner Hector Hernandez Owner Address 1401 S ROSEWOOD AVE City SANTA ANA State CA Zip 92707 Project Start Date 3/27/2025 Project End Date 3/27/2025 Project Work Shift(s)Day Building Size in Sq.ft 358 Number of Floors 1 Building Age (years)75 Number of Building/Dwelling Units 1 Building Prior Use Other garage Asbestos Survey Yes Asbestos Found No Asbestos Removed NA Building to be Demolished Yes Describe Work Demo garage to rebuild an ADU Describe Work Location garage area only Project Information Demolition Information All Asbestos containing materials must be removed prior to any demolition activity Survey Information 1401 S Rosewood Ave Unit# 2& 34/22/2025 Certified Asbestos Inspector Name Samuel Petra Certification Expiration Date​4/20/2025 12:00:00 AM Survey Plan Date 3/12/2025 12:00:00 AM Phone Number (951)946­0844 EMail sam@alphaenv.net Size of Demolition Project in sq. ft 358 Work Practices at Demolition Site Tarp Trucks/Bins , Fence Screens Contingency Demolition plan Stop Work , Isolate Work Area , Notify Owner , Stabilize , Secure , Characterize Waste , Survey Waste Information Waste Transporter P&P Morales Construction Inc Address 27702 Crown Valley Pkwy D4­107 City Ladera Ranch State CA Zip 92694   Landfill Prima Deshecha Landfill Address 32250 Avenida La Pata City San Juan Capistrano State CA Zip 92675 Fee Payment Size of Demolition Project in sq. ft 358 Tracking Number 4505811 Project Size Fee 79.23 Additional Fee 0 Total Fee $ 79.23 Payment Made $ 79.23 Balance Due $ 0 By clicking the Sign & Submit button, I certify that an individual trained in the provisions of SCAQMD Rule 1403 and the Asbestos NESHAP (CFR Title 40, Part 61, Subpart M) will be onsite during the demolition or renovation and evidence that the required training has been accomplished by this person will be available for inspection during normal business hours. In addition, I certify that all of the information contained herein and information submitted with this Notification is true and correct. 1401 S Rosewood Ave Unit# 2& 34/22/2025 SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa-ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Thai Viet Phan COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org INTERIM CITY MANAGER Tom Hatch CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall March 25, 2024 Also sent via email to: fo.studio11@gmail.com Monica Perez 1401 S. Rosewood Avenue Santa Ana, CA. 92707 Subject: Address Assignment for a new Accessory Dwelling Unit and a new Junior Accessory Dwelling Unit located at 1401 South Rosewood Avenue and (APN: 013- 051-01) in Santa Ana, CA Dear Monica, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a new Accessory Dwelling Unit and a new Junior Accessory Dwelling Unit located at 1401 South Rosewood Avenue and (APN: 013-051-01). Notice is hereby given that the following assigned address(es) shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address(es) to be Activated/Posted To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 667-2709 or by email at ASevilla@santa-ana.org. Sincerely, Alexis Sevilla Planning Technician Reviewed by: Jerry Guevara, Senior Planner 1401 S Rosewood Ave Unit# 2& 34/22/2025 Address Letter for 1401 S Rosewood Avenue Page 2 of 2 Exhibit A – Address Plan c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Mishele Richards, Orange County Fire Authority, GEO Files Coordinator Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Alvaro Nunez, PBA Assistant Director and Code Enforcement Manager 1401 S Rosewood Ave Unit# 2& 34/22/2025 Borchard Ave. 3/16" = 1'-0"1 Site CL CL CL (E)MAIN HOUSE: 1401 SOUTH ROSEWOOD AVE (N)JADU: 1401 SOUTH ROSEWOOD AVE UNIT 2 (N) ADU: 1401 SOUTH ROSEWOOD AVE UNIT 3 EXHIBIT A - ADDRESS PLAN 1401 S Rosewood Ave Unit# 2& 34/22/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area: Area to be Added: Total Resulting Area: Stories: Area Added in Past 2 Years (excluding this project): Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability (PR400-402) Fire Sprinkler 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has fire sprinklers or a house that will have fire sprinklers added as part of this project? (PR400-402) Fire Sprinkler 3.   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than 140-feet from the fire access roadway? *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all enclosed spaces, such as garages, stairs, and detached structures separated by less than 10-feet? *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed contractor to determine if a fire sprinkler modification is needed. (PR400-402) Fire Sprinkler 7.   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold set by local ordinance? *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 sf, and ADU’s). *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as defined by the State, or (D) near an area that could be affected by a wildfire in the open space. *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR 1401 S Rosewood Ave Unit# 2& 34/22/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area: Area to be Added: Total Resulting Area: Stories: Area Added in Past 2 Years (excluding this project): Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability (PR400-402) Fire Sprinkler 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has fire sprinklers or a house that will have fire sprinklers added as part of this project? (PR400-402) Fire Sprinkler 3.   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than 140-feet from the fire access roadway? *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all enclosed spaces, such as garages, stairs, and detached structures separated by less than 10-feet? *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed contractor to determine if a fire sprinkler modification is needed. (PR400-402) Fire Sprinkler 7.   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold set by local ordinance? *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 sf, and ADU’s). *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as defined by the State, or (D) near an area that could be affected by a wildfire in the open space. *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR 1401 S Rosewood Ave Unit# 2& 34/22/2025 1401 S Rosewood Ave Unit# 2& 34/22/2025 Page 1 of 1 EXISTING ONE & TWO FAMILY DWELLINGS ELECTRICAL SERVICES UNDERGROUND EXCEPTION CEC 2022 ELC-04 All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41- 626(b). There is a standing exception for one and two family dwellings. This exception applies only when the new electrical service is designed to be fed from below grade as well as overhead. This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the circuit breaker side of this cabinet. Only listed combination overhead and underground feed service boxes may be used to connect to an overhead utility drop. This exception to an underground fed service applies only to existing single family and two family residences. Planning & Building Agency Permits & Plan Check Section 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 Rigid Conduit Service Entrance Conductor Riser Underground Service Lateral METER Rev. 1/21/2020 1401 S Rosewood Ave Unit# 2& 34/22/2025