Loading...
HomeMy WebLinkAbout1022 S Hickory St - PlanSHEET CELL: 949-401-3370 INFO@YARDDES.COM Scale SHANI KRISPIN PR O J E C T N A M E : 10 2 2 S . H I C K O R Y S T . SA N T A A N A C A L I F O R N I A 9 2 7 0 1 DATE SH E E T T I T L E IRVINE, CA 92618 6 FOXCHASE YARD DESIGN PREPARED BY: AV I V R E S I D E N C E 00-G-000 1/16" = 1'-0" TI T L E S H E E T VICINITY MAP SCOPE OF WORK: - NEW 795 SQ FT DETACHED ADU SHEET LIST SHEET NUMBER 00-G-000 00-G-001 SHEET NAME TITLE SHEET 01-A-000 01-A-001 01-A-002 10/22/2024 SITE PLANS GENERAL NOTES APPROVAL STAMP THIS PROJECT SHALL COMPLY WITH THE STATE OD CALIFORNIA TITLE 24 AND THE FOLLOWING CODES: 2022 CALIFORNIA RESIDENTIAL CODE, TITLE 24 PART 2.5 2022 CALIFORNIA MECHANICAL CODE, TITLE 24 PART 3 2022 CALIFORNIA ELECTRICAL CODE, TITLE 24 PART 4 2022 CALIFORNIA PLUMBING CODE, TITLE 24 PART 5 2022 CALIFORNIA ENERGY CODE, TITLE 24, PART 6 2022 CALIFORNIA BUILDING CODE, TITLE 24 PART 2 ASSESSOR PARCEL NO. (APN): 011-075-21 LEGAL DESCRIPTION: N TR 466 BLK E LOT 28 TR 466 LOT SIZE: 8,100 SQFT BUILDING SIZE: 1,243 SQFT NO. OF STORIES: 1 CITY ZONING DESIGNATION: R-3 CONSTRUCTION TYPE: V-B LOT 28 BLK E AND N1/2 LOT 27 BLK E FRONT PORCH: 133 SQFT TWO CAR GARAGE: 324 SQFT LOT COVERAGE: 1,243 / 8,100 = 15.34% FIRE SPRINKLER: NO PROPOSED DETACHED ADU: 795 SQFT PROPOSED LOT COVERAGE: 2,038 / 8,100 = 25.1% GENERAL NOTES SECTIONS, ELEVATIONS 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE TITLE 24, PART 11 CITY OF SANTA ANA MUNICIPAL CODES LANDSCAPING NOTES: GENERAL NOTES: 00-G-002 GENERAL NOTES 02-GD-001 PROPOSED FLOOR PLANS GENERAL NOTES02-GD-002 GENERAL DETAILS02-GN-001 GENERAL DETAILS02-GN-002 FOUNDATION PLAN02-S1 ROOF FRAMING PLAN02-S2 DETAIL02-S3 TITLE 2403-T24-1 TITLE 2403-T24-2 GRADING/DRAINAGE NOTES04-GD-1 GRADING/DRAINAGE PLAN04-GD-2 DETAILS (DRAINAGE)04-GD-3 PROPOSED BUILDING SIZE: 1,243 SQFTNOTES: - THE ADU SF / SFD SF RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN “SFR SF” OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN “SFR SF” OF THE EXISTING RESIDENCE. SEPERATE PERMITS FOR THIS LOT: - POOL PERMIT #101119176 - NEW 75 LN FT FENCE AT FRONT OF THE HOUSE PROJECT CONSULTANTS: DESIGN: NAME: YARD DESIGN EMAIL: INFO@YARDDES.COM PHONE: (949) 401-3370 STRUCTURAL ENGINEER: NAME: SPS ENGINEERING EMAIL: SHANT.SPS@GMAIL.COM PHONE: (818) 747-7269 NAME: NALSER ENGINEERING EMAIL: NALSERENGINEERING@GMAIL.COM PHONE: (818) 913-7525 ENERGY: NAME: GEOMAX ENGINEERING EMAIL: GEOMAXENG@GMAIL.COM PHONE: (562) 806-2173 SOIL ENGINEER: NAME: CALCOAST ENGINEERING EMAIL: MANSOUR@CALCOASTENGINEERING.COM PHONE: (949) 235-5068 GRADING: ADU SF / SFD SF RATIO: 795 / 1243 = 63.95% 00-G-003 GENERAL NOTES 00-G-004 GENERAL NOTES - FOR NEW BUILDINGS AND ADDITIONS, ALTERATIONS, AND REPAIRS WITHIN ANY TWELVE-MONTH PERIOD EXCEED FIFTY (50%) PERCENT OF THE VALUE OF ANY EXISTING BUILDING OR STRUCTURE, EACH BUILDING OR STRUCTURE SHALL BE MADE TO CONFORM TO THE REQUIREMENTS FOR NEW BUILDINGS OR STRUCTURES AND COMPLY WITH THE BUILDING SECURITY REGULATIONS. SANTA ANA MUNICIPAL CODE CHAPTER 8, DIVISION 3. FLOOD ZONE: X 00-G-005 GRADING EXEMPT FORM THESE PLANS HAVE BEEN REVIEWED BY GEOMAX ENGINEERING, INC., THEY APPEAR TO BE IN CONFORMITY WITH OUR SOILS REPORT GE24033 DATED MAY 21, 2024. GEOMAX ENGINEERING, INC. IS NOT RESPONSIBLE FOR THE ACCURACY, DIMENSIONS, MEASUREMENTS OR ANY PORTION OF THE DESIGN. NOVEMBER 08, 2024 BLDG # 101120004 APPROVALS PLNG - FArias BLDG - CSG Consultants POLICE- BMartin 1022 S Hickory St 1/9/2025 11. CARBON MONOXIDE DETECTORS SHALL BE INTERCONNECTED SUCH THAT THE ACTIVIATION OF ONE ALARM WILL ACTIVIATE ALL ALARMS. CARBON MONOXIDE DETECTORS SHALL BE "HARD WIRED" AND SHALL BE EQUIPPED WITH BATTERY BACK UP. 10. AT BEDROOMS PROVIDE ONE OPENABLE ESCAPE WINDOW OR DOOR MEETING ALL OF THE FOLLOWING: AN OPENABLE AREA OF NO LESS THAN 5.7 SQ. FT., OVER 44 INCHES ABOVE THE FLOOR (CRC 310.4) A MINIMUM CLEAR 24 INCH HEIGHT AND 20 INCH WIDTH, AND A SILL HEIGHT NOT 1. COMPLY WITH MANDATORY MEASURES ATTACHED. SEE SHEET MF-1R 2. LIGHTING IN KITCHEN. ALL LUMINARIES SHALL BE HIGH EFFICACY. 3. LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS. ALL LUMINARIES SHALL BE HIGH EFFICACY. 4. OTHER ROOMS. ALL LUMINARIES SHALL BE HIGH EFFICACY. 5. OUTDOOR LIGHTING. ALL LUMINARIES MOUNTED TO THE BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINARIES AND SHALL BE CONTROLLED BY A PHOTOCONTROL/MOTION SENSOR COMBINATION. 6. HIGH EFFICACY LUMINARIES MUST BE PIN BASED. HIGH EFFICACY LAMP REQUIREMENTS: LAMP POWER RATING MIN. LAMP EFFICACY 15 WATTS OR LESS 40 LUMENS PER WATT 15 TO 40 WATTS 50 LUMENS PER WATT OVER 40 WATTS 60 LUMNES PER WATT 7. OCCUPANCY SENSORS MUST HAVE NO MANUAL OVERIDE, 30 MINUTE MAXIMUM TIMER AND BE MICROWAVE/ULTRASONIC OR PASSIVE INFRA-RED TYPE. 1. ELECTRICAL WORK SHALL COMPLY WITH 2022 CALIFORNIA ELECTRICAL CODE. 2. FOR A NEW OR REMODELED KITCHEN PROVIDE SMALL APPLIANCE AND DEDICATED CIRCUITS. THERE SHALL BE A MINIMUM OF TWO 20-AMPERE DEDICATED COUNTER TOP SMALL APPLIANCE CIRCUITS WITH OUTLETS LOCATED NO MORE THAN 20" OVER COUNTER TOP (2019 CEC 210.11 AND 210.52) 3. NEW OR REMODELED BATHROOMS REQUIRE A 20-AMPERE DEDICATED CIRCUIT. THIS CIRCUIT MAY SUPPLY RECEPTACLES ONLY. (2019 CEC 210.11 (C), 210.52(D) AND 210.23(A)) 4. THE CENTER OF 15-20-30 AMPERE RECERTACLES SHALL BE INSTALLED NOT LESS THAN 12" ABOVE THE FLOOR. 3-210-25 (g) 5. CENTER OF SWITCHES TO BE BETWEEN 3 & 4 FEET ABOVE THE FLOOR. 6. RECEPTACLES OULETS SHALL BE SPACED AT 12 FT. O. C. MAX, AND SHALL BE LOCATED WITHIN 6 FT. OF DOORS OPENING. 7. PROVIDE OUTDOOR RECEPTACLES WITH WEATHERPROOF COVER AND GROUND FAULT CIRCUIT INTERRUPTOR (G F C I ). ONE IN FRONT AND ONE IN BACK OF THE DWELLING IS THE MINIMUM REQUIREMENT. (2019 CEC 210.52) 8. ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE PHASE, 15 & 20 AMPERE RECEPTACLE OUTLETS INSTALLED IN BEDROOM, LIVING ROOM, FAMILY ROOM, DINING ROOM, KITCHEN, AND LAUNDRY ROOM SHALL BE PROTECTED BY A COMBINATION ARC-FAULT CIRCUIT INTERRUPTER'S) - 2019 CEC 210-12(b). 9. AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL325. (R309.4 CRC) LC EQ . EQ . TEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC. IF GLASS IS USED IT SHALL 6. ALL SHOWERS AND TUB-SHOWERS SHALL HAVE EITHER A PRESSURE BALANCE OR A HAVE A MINIMUM THICKNESS OF NOT LESS THAN 1/8" WHEN FULLY TEMPERED OR 1/4" WHEN 4. WATERCLOSETS AND SHOWER HEADS SHALL BE LOW CONSUMPTION (1.28 GAL/FLUSH W.C). LAMINATED AND SHALL PASS THE TEST REQUIREMENTS OF UBC STANDARD No 54-2. 5. WATERCLOSETS SHALL COMPLY WITH THE MINIMUM CLEARANCES SPECIFIED BELOW. THERMOSTATIC MIXING VALVE. (P.C.420.0) SMOOTH, HARD NON ABSORBENT SURFACES SUCH AS PORTLAND CEMENT, CONCRETE, CERAMIC TILE OR OTHER APPROVED MATERIAL TO A HEIGHT OF NOT LESS THAN 72 INCHES ABOVE THE MATERIALS OTHER THAN STRUCTURAL ELEMENTS USED IN SUCH WALLS SHALL BE MOISTURE 2. GLASS ENCLOSURE DOORS AND PANELS SHALL BE LABELED CATEGORY II. DOORS SHALL SWING OUTWARD. THE NET AREA OF THE SHOWER RECEPTOR SHALL BE NOT LESS THAN 1,024 1. SHOWERS AND TUBS WITH SHOWERS SHALL HAVE FLOORS AND WALLS FINISHED WITH 3. GLAZING USED IN DOORS AND PANELS OF SHOWER AND TUB ENCLOSURES SHALL BE FULLY SI OF FLOOR AREA, AND ENCOMPASS 30" DIAMETER CIRCLE. RESISTANT. DRAIN INLET. 6. WATER HEATER TO BE STRAPPED FOR LATERAL SUPPORT. PROVIDE UPPER & LOWER COMBUSTION AIR PIPE. 5. ALL EXTERIOR SWINGING DOORS SHALL BE WEATHER-STRIPPED. 1. PROVIDE A SMOKE DETECTOR AT ALL SLEEPING ROOMS MINIMUM OF 4 INCHES ABOVE THE CONTROLS (P.C. 701.1.2.2) ONE IN THE LOWER 1/3 OF THE TANK. THE LOWER POINT SHALL BE A WALL IN TWO PLACES. ONE IN THE UPPER 1/3 OF THE TANK AND 9. NEW OR REPLACEMENT WATER HEATERS SHALL BE STRAPPED TO THE 7. USE 2"X 6" WOOD STUDS @ 16"O.C. AT PLUMBING WALLS. 8. DUCTS SHALL BE SIZED PER CHAPTER 6 OF THE MECHANICAL CODE 4. ALL EXTERIOR RECEPTACLES AND THOSE INSTALLED IN BATHROOMS, GARAGES AND WITHIN 6 FEET FROM SINK ABOVE COUNTER SHALL BE PROTECTED BY GROUND RELIEF VALVE ON WATER HEATERS AND PIPE DRAINS TO EXTERIOR. ( AS PER CPC 505.4 AND 505.5) 3. PROVIDE A COMBINATION TEMPERATURE AMD PRESSURE WITH BATTERY BACK-UP AY NEW ROOMS ONLY. AT EXISTING BEDROOMS USE BATTERY OPPERATED SMOKE 2. ALL WATER PIPING WITHIN THE BUILDING STRUCTURE SHALL BE BONDED TOGETHER, MADE ELECTRICALLY CONTINUOUS AND BONDED IN TURN TO THE GROUNDING ELECTRODE CONDUCTOR AT THE SERVICE. AND HALLWAYS; SMOKE DETECTORS SHALL BE HARDWIRE DETECTORS. FAULT PROTECTION ( G.F.I. ) 3. GLAZING IN THE FOLLOWING LOCATIONS SHALL BE SAFETY GLAZING CONFORMING TO THE HUMAN IMPACT LOADS OF SECTION R308.3 (SEE EXCEPTIONS) (R308.4): A. FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BI-FOLD DOOR ASSEMBLIES. B. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE. C. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 1) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET. 2) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. 3) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. 4) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE GLAZING. E. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. G. GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 36 INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE OF STAIRWAYS, LANDINGS BETWEEN FLIGHTS OF STAIRS AND RAMPS. H. GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY WHERE THE GLAZING IS LESS THAN 36 INCHES ABOVE THE LANDING AND WITHIN 60 INCHES HORIZONTALLY OF THE BOTTOM TREAD. 12. PROVIDE EMERGENCY EXIT DOOR OR WINDOW FROM BASEMENT AND/OR SLEEPING ROOM(S) AND HABITABLE ATTICS. NET CLEAR WINDOW OPENING AREA SHALL BE NO LESS THAN 5.7 SQ. FT. (EXCEPT AT GRADE FLOOR OPENING SHALL BE MINIMUM 5.0 SQ. FT.) MIN. NEW WINDOW OPENING HEIGHT DIMENSION, 24" CLEAR, MIN. NET OPENING WIDTH DIMENSION, 20" CLEAR. FINISHED SILL HEIGHT MAX 44" ABOVE FLOOR. THE EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE OPERATIONAL FROM INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS, OR SPECIAL KNOWLEDGE. WINDOW OPENING CONTROL DEVICES COMPLYING WITH ASTM F2090 SHALL BE PERMITTED." CRC R310.1 13. WHERE MORE THAN ONE SMOKE ALARM IS REQUIRED THEY SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS IN THE DWELLING. CRC R314.4 14. COMBINATION SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL BE LISTED AND APPROVED IN ACCORDANCE WITH UL 217 AND UL 2034. CRC R314.1.1 15. SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WIT A BATTERY BACKUP. CRC 314.6,R315.5 16. DRAFTSTOPPING SHALL BE PROVIDED WHERE THERE IS USABLE SPACE ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR CEILING ASSEMBLY. THE DRAFT STOP SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1. ALL DUCTS WORK INSTALLED WITH A COMBINED LENGTH OF 40 FEET OR GREATER SHALL BE REQUIRED TO MEET PACKAGE D, REQUIRE A HERS RATER, AND SUBMIT. 2. CONDENSATE LINES FROM MECHANICAL EQUIPMENT SHALL DISCHARGE TO A PLUMBING FIXTURE OR STORM DRAIN BY MEANS OF AN INDIRECT WASTE PIPE. CONDENSATE LINES SHALL NOT DRAIN OVER A PUBLIC WAY. (310.1 CMC) 3. EACH BATHROOM CONTAINING A BATHTUB, SHOWER OR TUB/SHOWER COMBINATION SHALL BE MECHANICALLY VENTILATED FOR PURPOSES OF HUMIDITY CONTROL IN ACCORDANCE WITH CMC, CHAPTER 4 AND CGBSC, CHAPTER 4, DIVISION 4.5 HUMIDITY CONTROL SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF LESS THAN OR EQUAL TO 50% TO A MAXIMUM OF 80% (R303.3.1 CRC) 4.EVERY DWELLING UNIT SHALL BE PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF NOT LESS THAN 68°F AT A POINT 3 FEET ABOVE THE FLOOR AND 2 FEET FROM EXTERIOR WALLS. THE INSTALLATION OF PORTABLE SPACE HEATERS SHALL NOT BE USED TO ACHIEVE COMPLIANCE WITH THIS SECTION. SHOW SOURCE OF HEAT ON PLANS. (R303.9 CRC) 5. PROVIDE A SEDIMENT TRAP AT THE LOCATION OF THE WATER HEATER AND THE FAU OR WHERE A SEDIMENT TRAP IS NOT INCORPORATED AS PART OF THE APPLIANCE. A SEDIMENT TRAP MUST BE INSTALLED DOWNSTREAM OF THE APPLIANCE SHUTOFF VALVE AS CLOSE TO THE INLET OF THE APPLIANCE AS PRACTICAL, BUT BEFORE THE FLEX CONNECTOR, WHERE USED AT THE TIME OF APPLIANCE INSTALLATION. SEDIMENT TRAPS ARE NOT REQUIRED AT RANGES, CLOTHES DRYERS, DECORATIVE VENTED APPLIANCES, OR GAS FIREPLACES. (1313.7 CMC) 1. PIPING MATERIAL: WATER: COPPER TYPE "M" OR "L" SEWER/VENTS: ABS SCHED 40 2. WATER PIPING MATERIALS WITHIN A BUILDING SHALL BE IN ACCORDANCE WITH SEC. 604.1 OF THE CA PLUMBING CODE. PEX, CPVC AND OTHER PLASTIC WATER PIPING SYSTEMS SHALL BE INSTALLED IN ACCO WITH THE REQUIREMENTS OF SEC. 604 OF THE CPC, INSTALLATION STANDARDS OF APPENDIX I OF THE C MANUFACTURERS RECOMMENDED INSTALLATION STANDARDS. CPVC WATER PIPING REQUIRES A CERTIFICA COMPLIANCE AS SPECIFIED IN SEC 604.1.1(D) OF THE CPC PRIOR TO PERMIT ISSUANCE. 3. ALL HOSE BIBS MUST HAVE AN APPROVED ANTI-SIPHON DEVICE. (CPC 603.5.7) 4. SHOWER AND TUB-SHOWER COMBINATIONS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE, THERMOSTATIC, OR COMBINATION PRESSURE BALANCE/THERMOSTATIC MIXING VALVE TYPE THAT PROVIDED SCALD AND THERMAL SHOCK PROTECTION. THESE VALVES SHALL CONFORM TO ASSE 1016 OR ASME 112.18.1/CSA B125.1. HANDLE POSITION STOPS SHALL BE PROVIDED ON SUCH VALVES AND SHALL BE ADJUSTED PER THE MANUFACTURER'S INSTRUCTIONS TO DELIVER A MAXIMUM MIXED WATER SETTING OF 120°F. WATER HEATING THERMOSTATS SHALL NOT BE CONSIDERED A SUITABLE CONTROL FOR MEETING THIS PROVISION. (CPC 408.3). 5. ALL NON-COMPLIANT PLUMBING FIXTURES SHALL BE REPLACED WITH WATER-CONSERVING PLUMBING FIXTURES. (CIVIL CODE SECTION 1101.4(B)) NONCOMPLIANT PLUMBING FIXTURE MEANS ANY OF THE FOLLOWING: A. ANY TOILET MANUFACTURED TO USE MORE THAN 1.6 GALLONS OF WATER PER FLUSH. B. ANY URINAL MANUFACTURED TO USE MORE THAN ONE GALLON OF WATER PER FLUSH. C. ANY SHOWERHEAD MANUFACTURED TO HAVE A FLOW CAPACITY OF MORE THAN 2.5 GALLONS OF WATER PER MINUTE. D. ANY INTERIOR FAUCET THAT EMITS MORE THAN 2.2 GALLONS OF WATER PER MINUTE. 6. WATER CLOSETS SHALL HAVE AN AVERAGE WATER CONSUMPTION OF NOT MORE THAN 1.28 GALLONS PER FLUSH (411.2 CPC) 7. SHOWER HEADS SHALL HAVE A WATER FLOW NOT TO EXCEED 1.8 GALLONS PER MINUTE AT 80 PSI. (408.2 CPC) 8. THE MAXIMUM FLOW RATE OF LAVATORY FAUCETS SHALL NOT EXCEED 1.2 GALLONS PER MINUTE AT 60 PSI. (403.7 CPC) 9. FAUCETS IN KITCHENS SHALL HAVE A WATER FLOW NOT TO EXCEED 1.8 GALLONS PER MINUTE AT 60 PSI AND MAY TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM RATE, BUT NOT TO EXCEED 2.2 GALLONS PER MINUTE, AND MUST DEFAULT TO A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE. (407.2.1.1 CPC) 1/2" DRYWALL FINISH SHEARWALL SHEATHING (PER PLAN) 7/8" STUCCO EXTERIOR FINISH (PLASTER MIX 1:4 FOR SCRATCH COAT AND 1:5 FOR BROWN COAT, BY VOLUME, CEMENT TO SAND) OVER MOISTURE BARRIER 2X4 STUDS @ 16" O.C. INTERIOR R-15 INSULATION EXTERIOR1/2" DRYWALL FINISH R-15+R-5 INSULATION WALL R.R. SHEET CELL: 949-401-3370 INFO@YARDDES.COM Scale SHANI KRISPIN PR O J E C T N A M E : 10 2 2 S . H I C K O R Y S T . SA N T A A N A CA L I F O R N I A 9 2 7 0 1 DATE SH E E T T I T L E IRVINE, CA 92618 6 FOXCHASE YARD DESIGN PREPARED BY: AV I V R E S I D E N C E 00-G-001 1/16" = 1'-0" GE N E R A L N O T E S 08/07/2024 APPROVAL STAMP 1022 S Hickory St 1/9/2025 HEAT GAIN COEFFICIENT OF .23. MANUFACTURERS TO SUPPLY CERTIFICATE OF COMPLIANCE TO THE OWNER. SAFETY COMMISSION. 1. ALL NEW GLAZING SHALL COMPLY WITH STANDARDS OF THE U.S. CONSUMER PRODUCT NOTES: REQUIREMENTS OF TITLE 24 REPORT OR A CERTIFIED U-FACTOR OF .30 AND SOLAR 2. NEW GLAZED OPENING (WINDOWS & DOORS) SHALL BE LABELED TO INDICATE THE 3. THE NFRC TEMPORARY LABEL DISPLAYED ON THE WINDOWS MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED 4. 6. EXTERIOR DOORS SHALL MEET A MINIMUM 20 MINUTE FIRE RESISTANCE RATING WHEN TESTED ACCORDING TO NFPA 252. 5. EXTERIOR WINDOWS, WINDOW WALLS, GLAZED DOORS AND GLAZED OPENINGS WITHIN DOORS SHALL BE DUAL GLAZED WITH A MINIMUM OF ONE TEMPERED PANE DUAL GLAZING, OR BE GLASS BLOCK UNITS, OR BE 20 MINUTE FIRE-RATED OR MEET THE REQUIREMENTS OF SFM 12-7A-2. 3. THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN ACCORDANCE WITH ASTM E1300. SHEET CELL: 949-401-3370 INFO@YARDDES.COM Scale SHANI KRISPIN PR O J E C T N A M E : 10 2 2 S . H I C K O R Y S T . SA N T A A N A CA L I F O R N I A 9 2 7 0 1 DATE SH E E T T I T L E IRVINE, CA 92618 6 FOXCHASE YARD DESIGN PREPARED BY: AV I V R E S I D E N C E 00-G-002 1/16" = 1'-0" GE N E R A L N O T E S 11/07/2024 APPROVAL STAMP GENERAL NOTES: BATHROOM NOTES CLOTHES DRYER NOTES PLUMBING NOTE 1022 S Hickory St 1/9/2025 SHEET CELL: 949-401-3370 INFO@YARDDES.COM Scale SHANI KRISPIN PR O J E C T N A M E : 10 2 2 S . H I C K O R Y S T . SA N T A A N A CA L I F O R N I A 9 2 7 0 1 DATE SH E E T T I T L E IRVINE, CA 92618 6 FOXCHASE YARD DESIGN PREPARED BY: AV I V R E S I D E N C E 00-G-003 1/16" = 1'-0" GE N E R A L N O T E S 08/07/2024 APPROVAL STAMP 1022 S Hickory St 1/9/2025 SHEET CELL: 949-401-3370 INFO@YARDDES.COM Scale SHANI KRISPIN PR O J E C T N A M E : 10 2 2 S . H I C K O R Y S T . SA N T A A N A CA L I F O R N I A 9 2 7 0 1 DATE SH E E T T I T L E IRVINE, CA 92618 6 FOXCHASE YARD DESIGN PREPARED BY: AV I V R E S I D E N C E 00-G-004 1/16" = 1'-0" GE N E R A L N O T E S 08/07/2024 APPROVAL STAMP 1022 S Hickory St 1/9/2025 SHEET CELL: 949-401-3370 INFO@YARDDES.COM Scale SHANI KRISPIN PR O J E C T N A M E : 10 2 2 S . H I C K O R Y S T . SA N T A A N A CA L I F O R N I A 9 2 7 0 1 DATE SH E E T T I T L E IRVINE, CA 92618 6 FOXCHASE YARD DESIGN PREPARED BY: AV I V R E S I D E N C E 00-G-005 1/16" = 1'-0" GR A D I N G E X E M P T F O R M 10/22/2024 APPROVAL STAMP 1022 S Hickory St 1/9/2025 HEAT GAIN COEFFICIENT OF .23. MANUFACTURERS TO SUPPLY CERTIFICATE OF COMPLIANCE TO THE OWNER. SAFETY COMMISSION. 1. ALL NEW GLAZING SHALL COMPLY WITH STANDARDS OF THE U.S. CONSUMER PRODUCT NOTES: REQUIREMENTS OF TITLE 24 REPORT OR A CERTIFIED U-FACTOR OF .30 AND SOLAR 2. NEW GLAZED OPENING (WINDOWS & DOORS) SHALL BE LABELED TO INDICATE THE 3. THE NFRC TEMPORARY LABEL DISPLAYED ON THE WINDOWS MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED 4. 6. EXTERIOR DOORS SHALL MEET A MINIMUM 20 MINUTE FIRE RESISTANCE RATING WHEN TESTED ACCORDING TO NFPA 252. 5. EXTERIOR WINDOWS, WINDOW WALLS, GLAZED DOORS AND GLAZED OPENINGS WITHIN DOORS SHALL BE DUAL GLAZED WITH A MINIMUM OF ONE TEMPERED PANE DUAL GLAZING, OR BE GLASS BLOCK UNITS, OR BE 20 MINUTE FIRE-RATED OR MEET THE REQUIREMENTS OF SFM 12-7A-2. 3. THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN ACCORDANCE WITH ASTM E1300. SHEET CELL: 949-401-3370 INFO@YARDDES.COM Scale SHANI KRISPIN PR O J E C T N A M E : 10 2 2 S . H I C K O R Y S T . SA N T A A N A CA L I F O R N I A 9 2 7 0 1 DATE SH E E T T I T L E IRVINE, CA 92618 6 FOXCHASE YARD DESIGN PREPARED BY: AV I V R E S I D E N C E 01-A-000 1/8" = 1'-0" PR O P O S E D P L A N 04/10/2024 APPROVAL STAMP PROPOSED SITE PLAN GENERAL NOTES: BATHROOM NOTES CLOTHES DRYER NOTES PLUMBING NOTE FENCE ELEVATION 1022 S Hickory St 1/9/2025 SHEET CELL: 949-401-3370 INFO@YARDDES.COM Scale SHANI KRISPIN PR O J E C T N A M E : 10 2 2 S . H I C K O R Y S T . SA N T A A N A CA L I F O R N I A 9 2 7 0 1 DATE SH E E T T I T L E IRVINE, CA 92618 6 FOXCHASE YARD DESIGN PREPARED BY: AV I V R E S I D E N C E 01-A-000 1/8" = 1'-0" SI T E P L A N S 11/07/2024 APPROVAL STAMP PROPOSED SITE PLAN FENCE ELEVATION EXISTING SITE PLAN NOTES · · · FENCE CONSTRUCTION DETAIL (NO SCALE) 1022 S Hickory St 1/9/2025 CONCRETE FOOTING EARTH OF 15# FELT BACKING. PROVIDE 2 LAYERS 7/8" EXTERIOR CEMENT PLASTER OVER WIRE FABRIC AND 1 LAYER AT PLYWD SHEAR WALLS GALVANIZED METAL BASE SCREED PAVED AREA 2X MUD SILL STUD FRAMING WIRE FABRIC 2" M I N . 4" M I N . 3 1 / 2 " NOTE: 1. MINIMUM 26 GA. CORROSION-RESITANT OR PLASTIC WEEP SCREED WITH A MINIMUM VERTICAL FLANGE OF 3 1/2" SHALL BE PROVIDED AT OR BELOW FOUNDATION PLATE LINE ON EXTERIOR WALL SHEET CELL: 949-401-3370 INFO@YARDDES.COM Scale SHANI KRISPIN PR O J E C T N A M E : 10 2 2 S . H I C K O R Y S T . SA N T A A N A CA L I F O R N I A 9 2 7 0 1 DATE SH E E T T I T L E IRVINE, CA 92618 6 FOXCHASE YARD DESIGN PREPARED BY: AV I V R E S I D E N C E 01-A-001 1/4" = 1'-0" PR O P O S E D F L O O R P L A N S 11/07/2024 APPROVAL STAMP PROPOSED PLAN PROPOSED ATTIC PLAN TYPICAL GUTTER DETAIL (NO SCALE) ROOF NOTES: GENERAL NOTES: ROOF SPECS: TYPICAL WALL SIDING TYVEKâ HOMEWRAPâ R-5 RIGID INSULATION 7/16" PLYWOOD SHEATHING 2"x4" WOOD/METAL STUDS w/ R-15 BATT INSULATION 1/2" GYPSUM BOARD TYPICAL WALL - R-15 INSULATION 3"=1'0" PROPOSED ROOF PLAN SCREED DETAIL (NO SCALE) AGING-IN PLACE DESIGN NOTES: · · · · NOTES: · · · · · ADU ATTIC VENT CALCULATIONS:: SKYLIGHT SPECS: 1022 S Hickory St 1/9/2025 SHEET CELL: 949-401-3370 INFO@YARDDES.COM Scale SHANI KRISPIN PR O J E C T N A M E : 10 2 2 S . H I C K O R Y S T . SA N T A A N A CA L I F O R N I A 9 2 7 0 1 DATE SH E E T T I T L E IRVINE, CA 92618 6 FOXCHASE YARD DESIGN PREPARED BY: AV I V R E S I D E N C E 01-A-002 1/4" = 1'-0" 10/22/2024 SHEET CELL: 949-401-3370 INFO@YARDDES.COM Scale SHANI KRISPIN PR O J E C T N A M E : 10 2 2 S . H I C K O R Y S T . SA N T A A N A CA L I F O R N I A 9 2 7 0 1 DATE SH E E T T I T L E IRVINE, CA 92618 6 FOXCHASE YARD DESIGN PREPARED BY: AV I V R E S I D E N C E 1/4" = 1'-0" SE C T I O N S 10/22/2024 APPROVAL STAMP SECTION 1SECTION 2 EL E V A T I O N S SIDE ELEVATION 2 - SOUTH SIDE ELEVATION 4 - NORTH FRONT ELEVATION 1 - EAST BACK ELEVATION 3 - WEST NOTES 1022 S Hickory St 1/9/2025 No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # S.S. S.S. N.T.S. 23-572 AD D R E S S : 11 0 2 0 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 11/23/2023 10/23/2024 GN1 GE N E R A L NO T E S 1022 S Hickory St 1/9/2025 4 4 No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # S.S. S.S. N.T.S. 23-572 AD D R E S S : 11 0 2 0 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 11/23/2023 2/7/2024 GD1 GE N E R A L DE T A I L S 1022 S Hickory St 1/9/2025 DO NOT cut, notch or drill holes in headers or beams except as indicated in illustrations and tables. 1.3E TimberStrand®LSL allowed hole zone dd Microllam®LVL and Parallam® PSL allowed hole zone middle 13 span 1.3E TimberStrand® LSL hole zone Microllam®LVL and Parallam® PSL hole zone 2 x diameter of the largest hole (minimum) d 13 depth 1" 2" 13 4" Maximum Round Hole Size Header or Beam Depth 43 8" 714"- 20" 512" See illustration for Allowed Hole Zone ALLOWABLE HOLES - Headers and Beams General Notes No holes in headers or beams in plank orientation. Allowed hole zone suitable for headers and beams with uniform loads only. Round holes only No holes in cantilevers. Other Trus Joist® Beams No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # S.S. S.S. N.T.S. 23-572 AD D R E S S : 11 0 2 0 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 11/23/2023 11/7/2024 GD2 GE N E R A L DE T A I L S 1022 S Hickory St 1/9/2025 No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # S.S. S.S. N.T.S. 23-572 AD D R E S S : 11 0 2 0 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 11/23/2023 2/7/2024 GN1 GE N E R A L NO T E S 1022 S Hickory St 1/9/2025 No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # S.S. S.S. N.T.S. 23-572 AD D R E S S : 11 0 2 0 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 11/23/2023 11/7/2024 GN1 GE N E R A L NO T E S 1022 S Hickory St 1/9/2025 No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # S.S. S.S. N.T.S. 23-572 AD D R E S S : 11 0 2 0 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 11/23/2023 11/7/2024 GN2 GE N E R A L NO T E S 1022 S Hickory St 1/9/2025 FOUNDATION PLAN SCALE: 1/4" = 1' 1. PROVIDE A WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MINIMUM 4" ABOVE THE EARTH OR 2" ABOVE PAVED AREAS. 2. HOLD-DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. 3. HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE WASHERS; AND HOLD-DOWNS SHALL BE TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE STEEL PLATE WASHERS IN ACCORDANCE WITH TABLE 2306.5 OF THE LABC. 4. FOUNDATION ANCHOR BOLTS IN WALLS WITH LATERAL LOADS GREATER THAN 300 POUNDS/FOOT SHALL HAVE AN APPROVED PLATE WASHER UNDER EACH NUT; AND THE NUTS SHALL BE TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. 5. UNO THE FOUNDATION BOLTS SHALL BE 5/8" DIA. WITH 3"x3"x1/4" PLATE WASHERS EMBEDDED AT LEAST 9 INCHES INTO THE CONCRETE (OR) MASONRY FOUNDATION SPACED NOT MORE THAN 6 FEET APART. 6. MIN 2 BOLTS PER PIECE OF SILL PLATE AND ONE LOCATED WITHIN 12" AND NOT LESS THAN 7 BOLT DIAMETER OR 4-3/8" OF EACH END OF EACH SILL PLATE. 7. FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. 8. ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED. PLATE WASHERS ARE REQUIRED FOR ALL HOLDOWNS. 9. ALL FOUNDATION EXCAVATIONS MUST BE OBSERVED AND APPROVED BY THE PROJECT ENGINEERING GEOLOGIST AND/OR PROJECT GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT OF REINFORCING STEEL. 10. IF ADVERSE SOIL CONDITIONS ARE IN ENCOUNTERED, A SOILS INVESTIGATION REPORT MAY BE REQUIRED. 11. PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIAMETER AND FULL DIAMETER FOR SMOOTH SHANK PORTION. 12. FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. NOTES: DENOTES NEW FOOTING LEGEND: 4x4 POST INTERIOR WALL (U.N.O.) SHEAR WALL PER PLAN 4x6 POST EXTERIOR WALL (U.N.O.) No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # AD D R E S S : 11 0 2 0 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 S.S. S.S. 23-572 11/23/2023 11/7/2024 1/4” = 1’-0” S1 FO U N D A T I O N PL A N NOVEMBER 08. 2024 1022 S Hickory St 1/9/2025 ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE JOINTS OCCURRING IN BRACED WALL PANELS SOLID BLOCKING SHALL BE PROVIDED AT ALL HORIZONTAL COMMON NAILS OR GALVANIZED BOX. 1" Ø BOLT - 3.5"x3.5"x3/8" b) 3 x STUDS AND BLOCKS BETWEEN ADJACENT PANELS c) 1/2" EDGE DISTANCE FOR PLYWOOD BOUNDARY NAILING d) ALL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED. e) SQUARE PLATE WASHERS SHALL BE USED WITH ANCHOR BOLTS 5/8" Ø BOLT - 3"x3"x1/4" 7/8" Ø BOLT - 3"x3"x5/16" a) 3 x FOUNDATION SILL PLATES ALL SHEAR WALLS WITH A SHEAR VALUE GREATER THAN 300 lb/ft SHOULD BE PROVIDED: 3/4" Ø BOLT - 3"x3"x5/16" d) STAGGER NAILS IF NAIL SPACING IS LESS THAN 2" O.C. 2. DOUBLE JOISTS ARE REQUIRED UNDER PARALLEL BEARING PARTITIONS. 3. AN AITC CERTIFICATE OF INSPECTION FOR ALL GLU-LAM BEAMS INCLUDING PARALLAM BEAMS SHALL BE SUBMITTED TO THE BUILDING AND SAFETY DEPT. PRIOR TO ERECTION. 4. GLUE LAM BEAMS MUST BE FABRICATED IN A LADBS LICENSED SHOP. IDENTIFY GRADE SYMBOL AND LAMINATION SPECIES PER T 5A, 2005 NDS SUPP. 6. SHOP WELDS MUST BE PERFORMED IN A LADBS LICENSED FABRICATORS SHOP. 8. ALL WOOD MEMBERS MUST BE GRADE MARKED WITH GRADE AND SPECIES. 9. BEARING WALL STUDS CANNOT BE NOTCHED MORE THAN 25% OF THEIR WIDTH. BORED HOLES CANNOT HAVE A DIAMETER GREATER THAN 40% OF THE STUD WIDTH 10. PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIAMETER AND FULL DIAMETER FOR SMOOTH SHANK PORTION. 11. STRUCTURAL OBSERVATION IS REQUIRED FOR ALL PLYWOOD SHEAR WALLS WITH A DESIGN LOAD OVER 300 PLF. 12. ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 14. EXTERIOR STAIRS AND BALCONIES MUST BE POSITIVELY ATTACHED TO THE STRUCTURE WITHOUT THE USE OF TOE NAILS OR NAILS IN WITHDRAWAL. 16. CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/ COMPONENT LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE LADBS INSPECTORS AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT PER SEC 1706.1 17. CONTINUOUS SPECIAL INSPECTION REQUIRED BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING, CONCRETE STRENGTH f'c>2500 PSI, HIGH STRENGTH BOLTING, SPRAYED-ON FIREPROOFING, ENGINEERED MASONRY, HIGH-LIFT GROUTING, PRE-STRESSED CONCRETE, HIGH LOAD DIAPHRAGMS AND SPECIAL MOMENT-RESISTING CONCRETE FRAMES. 7. LADBS LICENSED FABRICATOR IS REQUIRED FOR STRUCTURAL STEEL. 18. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS, AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING, AND OTHER FASTENING TO COMPONENTS OF THE SEISMIC FORCE RESISTING SYSTEM. SPECIAL INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED WHERE THE FASTENER SPACING OF THE SHEATHING IS MORE THAN 4 INCHES ON CENTER. 13. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.7 15. ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED. 1. ALL WALLS OVER 10' IN HEIGHT TO BE 2x6 @16" O.C. FRAMING. NOTES: FRAMING BOUNDARY 4x4 POST INTERIOR WALL (U.N.O.) SHEAR WALL PER PLAN FRAMING MEMBERS LEGEND: POST FROM ABOVE ON TOP OF BEAM/HEADER ON TOP OF BEAM/HEADER POST W/STRAP OR HOLDOWN FROM ABOVE ON TOP OF POST BELOW POST FROM ABOVE W/STRAP OR HOLDOWN POST FROM ABOVE ON TOP OF POST BELOW ROOF SHEATHING: 5/8" CDX PLYWOOD STANDARD PS I-95 INDEX 32/16 DOUGLAS FIR-LARCH W/10d COMMON NAILS @ 6"_6"_10" O.C. 19. FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. 20. FIELD WELDING TO BE DONE BY WELDERS CERTIFIED BY THE LADBS. CONTINUOUS INSPECTION IS REQUIRED, 21. A COPY OF THE LOS ANGELES RESEARCH REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE. 4x6 POST EXTERIOR WALL (U.N.O.) ROOF FRAMING PLAN SCALE: 1/4" = 1' 380 650 498 PLATE TO BLKG. REQUIREMENTS SDS 1/4"x 6 SDS 1/4"x 6 SDS 1/4"x 6 SHEAR WALL SCHEDULE 12" O.C. PANEL NAILING 12" O.C. 12" O.C. 12" O.C. 10d @215/32" PLYWOOD 15/32" PLYWOOD STRUCTURAL 1 STRUCTURAL 1 STRUCTURAL 1 15/32" PLYWOOD4 3 2" O.C. 10d @ 10d @ 3" O.C. 4" O.C. OF SHEAR STRUCTURAL 1 WALL MATERIAL 15/32" PLYWOOD DESCRIPTION TYPE 1 PERIMETER 6" O.C. 10d @ 10d @ 12" O.C. OR LPT4 @ 8" O.C. 8" O.C. OR 10" O.C. OR LPT4 @ 10" O.C. LPT4 @ 12" O.C. 10d @ 10d @ A35 @ A35 @ @ 4" O.C. @ 8" O.C. @ 6" O.C. REQUIREMENTS BLKG. TO PLATE 16" O.C. OR CONNECTION LPT4 @ 16" O.C. 10d @ FIELD A35 @ A35 @ CONNECTION @ 6" O.C. 20d NAILS OR 5/8" Ø @ 24" O.C. 3/4" Ø @ 32" O.C. 3/4" Ø @ 32" O.C. 5/8" Ø @ 32" O.C. 3/4" Ø @ 48" O.C. OR OR 9" 9" 9" 9" 9" 3/4" Ø @ 6'-0" O.C. 5/8" Ø @ 48" O.C. 5/8" Ø @ 32" O.C. ANCHOR BOLTS FOUND CONN. SILL PLATE TO OR 9" 255 ANCHOR EMB. BOLTS 9" 9" ALLOWABLE SHEAR LOAD PLF No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # AD D R E S S : 11 0 2 0 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 S.S. S.S. 23-572 11/23/2023 11/7/2024 1/4” = 1’-0” S2 RO O F F R A M I N G PL A N 1022 S Hickory St 1/9/2025 No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # S.S. S.S. N.T.S. 23-572 AD D R E S S : 11 0 2 0 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 11/23/2023 10/23/2024 S3 DE T A I L OCTOBER 25, 2024 1022 S Hickory St 1/9/2025 10-23-2024 SHEET NO. DATE: Wo o d l a n d H i l l s , C A 9 1 3 6 4 21 7 3 1 V e n t u r a B l v d . S u i t e 1 1 0 Em a i l : p e r e n e r g y t 2 4 @ g m a i l . c o m RO M B T 2 4 P h : ( 8 1 8 ) 3 1 4 - 9 2 8 0 CHECKED BY: DRAWN BY:O.M. DATE# PROJECT: DE S C R I P T I O N : AD D R E S S : 23-216 ROMB T24 NE W A D U 10 2 0 S . H I C K O R Y S T . SA N T A A N A C A 9 2 7 0 1 OW N E R : 1 2 3 . REVISION T24-1 1022 S Hickory St 1/9/2025 10-23-2024 SHEET NO. DATE: Wo o d l a n d H i l l s , C A 9 1 3 6 4 21 7 3 1 V e n t u r a B l v d . S u i t e 1 1 0 Em a i l : p e r e n e r g y t 2 4 @ g m a i l . c o m RO M B T 2 4 P h : ( 8 1 8 ) 3 1 4 - 9 2 8 0 CHECKED BY: DRAWN BY:O.M. DATE# PROJECT: DE S C R I P T I O N : AD D R E S S : 23-216 ROMB T24 NE W A D U 10 2 0 S . H I C K O R Y S T . SA N T A A N A C A 9 2 7 0 1 OW N E R : 1 2 3 . REVISION T24-2 1022 S Hickory St 1/9/2025 AR C H I T E C T / D E S I G N E R : REVISION BY:DRAWN BY: SHEET NO.: PROJECT NUMBER: ISSUED DATE: PLOT DATE: DE V E L O P E R : LO C A T I O N : DATENO.DESCRIPTION. REVISIONS A.N. 10 2 0 S H I C K O R Y S T GR A D I N G / D R A I N A G E N O T E S PROJECT INFORMATION SCOPE OF WORK: OWNER CIVIL ENGINEER ADDRESS: Signed @ 4-27-24 by Arsalan GENERAL GRADING NOTES: 1.All grading shall comply with the latest CBC Chapters 18 and 33, and Appendix J and the Santa Ana Municipal Code. A City grading permit is required for grading. 2.Grading shall not be started without first notifying the City Grading Inspector. A pre-grading meeting on the site is required before starting of grading with the following people present: Grading Contractor, Design Civil Engineer, Geotechnical Engineer, Grading Inspector and when required, the Archaeologist and Paleontologist. The required inspections for grading will be explained at this meeting. 3.An approved copy of the grading plans shall be on the permitted site while work is in progress. 4.The Design Civil Engineer shall be available during the grading to verify compliance with the plans, specifications, code and any special conditions of the permit within his purview. 5.The Geotechnical Engineer shall perform periodic inspections and submit a complete report and map upon completion of the rough grading. The compaction report and approval from the Geotechnical Engineer shall indicate the type of field testing performed. Each test shall be identified with the method of obtaining the in-place density, whether sand cone or drive ring, and shall be so noted for each test. Sufficient maximum density determinations shall be performed to verify the accuracy of the maximum density curves by the field technician. 6.Cut and fill slopes shall be no steeper than 2 foot horizontal to 1 foot vertical (2:1) except where specifically approved otherwise. 7.Fills shall be compacted throughout to a minimum of 90% relative density. Aggregate base for asphaltic areas shall be compacted to minimum of 95% relative density. Maximum density shall be determined by uniform building code standard No. 70-1 or approved equivalent, and field density by uniform code standard no. 70-2 or approved equivalent. 8.The Contractor shall not create any trench or excavation 5-feet or more without the necessary permit from the State of California Division of Industrial Safety. 9.All cut slopes shall be investigated both during and after grading by the Geotechnical Engineer to determine if any slope stability problem exists. Should excavation disclose any geological hazards or potential geological hazards, the Geotechnical Engineer shall submit a recommended treatment to the City Engineer for approval. 10.The permittee is responsible for dust control measures. Water active sites at least twice daily. 11.The locating and protection of all existing utilities is the responsibility of the permittee. 12.Grading operations, including maintenance of equipment, within one-half (1/2) mile of a structure of human occupancy shall not be conducted between the hours of 8:00 p.m. and 7:00 a.m. on weekdays, including Saturday, or any time on Sunday or a federal holiday. (City of Santa Ana Municipal Code Section 18-314) 13.The permittee shall give reasonable notice to the owner of adjoining lands and buildings prior to beginning excavations, which may affect the lateral and subjacent support of the adjoining property. The notice shall state the intended depth of excavation and when excavation commences. The adjoining owner shall be allowed at least 30 days and reasonable access on the permitted property to protect his structure, if he so desires, unless otherwise protected by law. 14.All existing drainage courses through the site shall remain open to handle the storm water; however, in any case, the permittee shall be held liable for any damage due to obstructing natural drainage patterns. 15.Approved erosion protection devices shall be provided and maintained during the rainy season and shall be in place at the end of each day’s work. Proper erosion control measures must be shown on the plans. 16.Construction sites shall be maintained in such a condition that an anticipated storm does not carry wastes or pollutants off the sites. Discharges of material other than storm water are allowed only when necessary for performance and completion of construction practices and where they do not: cause or contribute to a violation of any water quality standard; cause or threaten to cause pollution, contamination, or nuisance; or contain a hazardous substance in a quantity reportable under Federal Regulations 40 CFR 117 and 302. Potential pollutants include but are not limited to: solid or liquid chemical spills; wastes from paints, stains, sealants, glues, limes, pesticides, herbicides, wood preservatives and solvents; asbestos fibers, paint flakes or stucco fragments; fuels, oils, lubricants, and hydraulic radiator or battery fluids; fertilizers, vehicles/equipment wash water and concrete wash water; concrete, detergent or floatable wastes; wastes from any engine/equipment steam cleaning or chemical degreasing; and superchlorinated potable water line flushings. During construction, disposal of such materials should occur in a specified and controlled temporary area on-site, physically separated from potential storm water run-off, with ultimate disposal in accordance with local, state, and federal requirements. 17.Dewatering of contaminated groundwater, or discharging contaminated soils via surface erosion is prohibited. Dewatering of non-contaminated groundwater requires a National Pollutant Discharge Elimination System (NPDES) permit from the respective State Regional Water Quality Control Board. 18.All dirt, sand, mud, or debris deposited or spilled upon public streets during any grading, hauling, or export operations shall be immediately cleaned up by the Developer, his Contractor, Subcontractors, or agents to the satisfaction of the City Engineer. Failure to do so will be cause for stopping all such grading, hauling, or export work by the City until such time as the streets are cleaned. 19.All trucks hauling dirt, sand, oil, or other loose materials are to be covered or should maintain a least two feet of freeboard in accordance with the requirements of CVC Section 23114. 20.Contractor is responsible for the repair of all damages to public properties that are caused by the work on-site. Repair must be completed to the satisfaction of the City Engineer. 21.Minimum asphalt pavement sections shall be: 3”AC/6”AB - parking aisles 4”AC/8”AB - drives [commercial] 4”AC/12”AB - drives [industrial] 3” A.C. over 4” A.B. - Parking Stalls [multi-family] 3” A.C. over 8” A.B. - Drive aisles [multi-family] 22.Earthwork Volumes: Cut 5 cubic yards (Fine Grading) Fill 5 cubic yards (Fine Grading) Net 0 cubic yards EROSION AND SEDIMENT CONTROL GENERAL NOTES 1.All work shall be in accordance with the erosion control plans, the project’s Storm Water Pollution Prevention Plan (SWPPP), and the recommendations of soils report. 2.Erosion control measures shall be in place at the end of each working day whenever the daily rainfall probability exceeds 40%. 3.Equipment and workers for emergency work shall be made available at all times during the rainy season. Necessary materials shall be available on site and stockpiled at convenient locations to facilitate rapid construction of temporary erosion control devices at all time. 4.Controls shall be set up and maintained as construction proceeds. Adjustments to the erosion control plans are allowable as required and approved by city. 5.All erosion and sediment control measures shall implement structural and nonstructural Best Management Practices (BMPs) in conformance with the guidelines of the California Storm Water BMP Handbooks. 6.After a rainstorm, all sediment and debris shall be removed from streets, berms and desilting basins. Any graded slope surface protection measures damaged during a rainstorm shall be immediately repaired. 7.The permittee and contractor shall be responsible and shall take necessary precautions to prevent trespass onto areas where impounded water created a hazardous condition. 23.If the net volumes exceed 500 cubic yards, the Contractor must submit a haul truck route to the city for approval. Haul route shall include the location of borrow and/or dispersal site, all streets included in the route, the proposed staging area and the maximum gross weight of the trucks when loaded. 24.Submit an 8 ½” x 11” haul route map of appropriate scale which indicates the location of the project site, showing streets and direction of hauling up to and including the end of the route. 25.Pursuant to Assembly Bill 3019, no excavation permit is valid unless the contractor contacts and obtains an Inquiry I.D. number from “Underground Service Alert” (1-800-422-4133) at least two working days prior to commencing excavation. 26.Separate permits must be obtained from the City Building and Safety Division for the construction of retaining walls, light poles, trash enclosures, on-site plumbing and all building structures. 27.All fonts on plans should be a minimum of 0.1”. 1022 S Hickory St 1/9/2025 AR C H I T E C T / D E S I G N E R : REVISION BY:DRAWN BY: SHEET NO.: PROJECT NUMBER: ISSUED DATE: PLOT DATE: DE V E L O P E R : LO C A T I O N : DATENO.DESCRIPTION. REVISIONS A.N. 10 2 0 S H I C K O R Y S T GR A D I N G & D R A I N A G E P L A N LEGEND (N) 4"PVC DRAIN PIPE, SDR-35 @ 2% MIN. SLOPE (N) DOWNSPOUT WITH SPLASH BLOCK (N) DRAIN INLET, SEE DETAIL 1, SHEET GD-3 (N) ROOF GUTTER (N) HIGH POINT 1.Prior to construction of any drainage system, verify its outlet elevation to assure positive drainage. in case of any discrepancies, contact the engineer. 2.Top of new drain inlets to be set below the finished surface/ finished grade elevations in order to provide positive drainage. in case of any discrepancies, contact the engineer. 3.In case of any discrepancies with the shown drain inlets tops and flowlines, or in case of any differing site conditions, contact the engineer. 4.Before backfilling any drainage system contact the engineer for field inspection and approval. 5.Connect new and active roof downspouts, deck drains, planter drains, and retaining walls sub-drains to the nearest landscaped area, more than 10' feet away from the building, otherwise, to the new drainage system, where occurs. 6.Connect existing drainage system to new drainage where occurs. 7.Drainage shall be maintained and constructed in accordance with The latest City of Santa Ana municipal code and the 2022 California Building Code. DRAINAGE CONSTRUCTION NOTES GRADING NOTES: 1.All existing and proposed grades should be field verified. 2.No utility search was conducted. the contractor shall shall be responsible to protect utilities or structures discovered on the site and shall notify the owner/engineer immediately to resolve any conflicts or issues with the proposed grading. 3.Grading and/or landscape contractor shall grade all areas to provide positive drainage (2% minimum) and shall construct mounds and swales in a manner not to cause any ponding/low point. 4.Slope all areas to drain at minimum 2%. slope finish surfaces and drain lines at minimum 1%. 5.Any public improvements such as sidewalk, curb and gutter, alley/street pavement damaged during construction, shall be replaced in kind by the contractor. 6.An approved encroachment permit is required for all work within the public right-of-way. 7.See Architectural Plans for cross sections and elevations. 8.Top of drains to be set at finished surface/ finished grade elevation to provide positive drainage 9.Connect roof downspout to new drainage system where shown on plans connect retaining wall sub drain to new drainage system where shown on plans. 10.Connect existing drainage system to new drainage where occurs 11.The grading plans shall at a minimum, conform to all requirements of Sections 107 and 110 of the California Building Code, including the following: a.All site/grading plans shall be based upon an accurate boundary line survey with monument and horizontal/vertical control disposition shown on the plans;(section 107.2.5 California Building Code); b.Demolition work for improvements to be removed and/or protected in place; c.The Contractor shall obtain a separate permit for all work within the street right-of-way. Also, d.Add a clear note on the plans stating, "no work is to be performed in public right of way prior to obtaining a separate public property encroachment permit." e.It shall be the responsibility of the Contractor to locate the utilities of every nature whether shown hereon or not and to protect them from damage. The Contractor shall bear total cost of repair or replacement of said utilities damaged by operations. f.All work shall be in conformance with the latest NP DES permit and the City's adopted Low Impact Development (LID) requirements. g.It is the responsibility of the contractor to ensure that all imported and exported soil is free of the Red Imported Fire Ant (RIFA). 12.Every excavation on a site located 5 ft or less from the street lot line shall be enclosed with a barrier not less than 6 ft in height. [CBC 3306.9] (N)PERCOLATION/GRAVEL TRENCH, 15' LONG x 18" WIDE x 3' DEEP SEE DETAIL 2, SHEET GD-3 (E) EXISTING (N) NEW FS FINISHED SURFACE FG FINISHED GRADE H.P. HIGH POINT TYP. TYPICAL C.Y. CUBIC YARD PROJECT NORTH (N) 4" PVC CLEANOUT ABBREVIATIONS TG TOP OF GRATE INLET (INLET ELEVATION) FL FLOW LINE ELEVATION 1022 S Hickory St 1/9/2025 AR C H I T E C T / D E S I G N E R : REVISION BY:DRAWN BY: SHEET NO.: PROJECT NUMBER: ISSUED DATE: PLOT DATE: DE V E L O P E R : LO C A T I O N : DATENO.DESCRIPTION. REVISIONS A.N. 10 2 0 S H I C K O R Y S T DE T A I L S ( D R A I N A G E ) TYPICAL PAVED AREA DRAIN TYPICAL UNPAVED AREA DRAIN 1022 S Hickory St 1/9/2025 Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)-647-5800 www.santa-ana.org GRADING PERMIT REQUIREMENTS FOR DETACHED ADU PROJECTS PCC-15 REV: 09/03/2020 Page 1 of 1 A grading permit is required for all new detached buildings including new detached Accessory Dwelling Unit (ADU) projects. Grading plans prepared and stamped by a registered professional engineer shall be submitted for approval prior to issuance of the building permit, and shall be required to be submitted before or concurrently with the architectural plans submittal to the Building Safety Division. Grading Permit Exemption: Residential detached Accessory Dwelling Unit (ADU) projects that meet all of the following may be exempted from grading permit requirements: 1.The maximum amount of soil being moved is less than 50 cubic yards. The soil quantities shall be calculated by a California registered professional civil engineer 2.A site drainage plan prepared by a California registered professional civil engineer shall be provided with the following minimum information, but not limited to: a.Plan(s) shall be stamped, signed and dated by a California registered civil engineer b.Location of all existing and proposed structures, property lines, right-of-way lines, and easements, including dimensions and setbacks c.Drainage slopes and flow patterns d.Drainage system such as swales, french drains, water collection and disposal system, etc. e.Drainage plan shall indicate how the site grading or drainage system will manage all surface water flows to be diverted away from buildings and adjoining property lines, in accordance with all applicable codes f.The grade shall fall not fewer than 6 inches within the first 10 feet from the foundation wall. Where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, drains, or swales shall be constructed to ensure drainage away from the structure. Impervious surfaces within 10 feet of the building foundation shall be sloped not less than 2 percent away from the building. 3.A final certification letter from the professional engineer of record stating that the grades were constructed per the approved site drainage plan, shall be submitted to the building inspector prior to final inspection 4.The “Detached ADU Grading Permit Exemption Checklist” shall be completed by the California registered professional civil engineer and shall be made a part of the building plans. 5.The site drainage plan and the completed checklist shall be required at the time of architectural plans submittal as part of the building plans package. The building official reserves the right to require a grading plan based on site conditions. This grading permit exemption does not apply to projects in the FEMA Flood Zone. 1022 S Hickory St 1/9/2025 Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)-647-5800 www.santa-ana.org DETACHED ADU - GRADING PERMIT EXEMPTION CHECKLIST PCC-16 REV: 11/10/2020 Page 1 of 1 THIS FORM SHALL BE COMPLETED BY A CALIFORNIA REGISTERED CIVIL ENGINEER. Instructions: In order to qualify for the grading permit exemption for detached Accessory Dwelling Unit (ADU) projects per handout PCC-15, the registered civil engineer of record shall complete all sections, check all boxes and sign the certification section below. A copy of this checklist shall be attached to each of TWO sets of plans. If answering NO to any of the questions, a grading plan and permit shall be required. Project Address: Yes No 1. ☐ ☐ I have verified that the project address is NOT located on a FEMA designated flood zone (Zone A or AE). 2. ☐ ☐ I have provided two sets of site drainage plans that is stamped, signed and dated by a California professional civil engineer, to be submitted with the building submittal package. 3. ☐ ☐ I have calculated the total amount of soil being cut or filled on this project is less than 50 cubic yards. 4. ☐ ☐ The site drainage plans include the following, but not limited to, location of all existing and proposed structures, property lines, right-of-way lines, and easements, including dimensions and setbacks; drainage slopes and flow patterns, drainage systems such as swales, french drains, water collection and disposal systems, etc. 5. ☐ ☐ I have designed drainage such that surface water flows away from buildings and adjoining property lines, in accordance with all applicable codes. 6. ☐ ☐ I have designed grading such that it will not adversely affect the adjoining properties. 7. ☐ ☐ I have designed the grade to fall not fewer than 6 inches within the first 10 feet from the foundation walls except where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, I have designed drains or swales to ensure drainage away from the buildings. Any impervious surfaces within 10 feet of the building foundation are sloped not less than 2 percent away from the building. 8. ☐ ☐ I will provide a final certification letter stating that the grades were constructed per the approved site drainage plan, and will submit this certification letter to the building inspector prior to final inspection. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Licensed Number: Date: Phone Number: Email Address: x x x x x x x x ARSALAN NADERI, P.E. C50354 06-08-24 (949) 235-5068 CELL (949) 715-9990 OFFICE Arsalan@CalCoastEngineering.com 1022 S HICKORY ST., SANTA ANA, CA 92701 1022 S Hickory St 1/9/2025 SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa-ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Thai Viet Phan COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org ACTING CITY MANAGER Alvaro Nuñez CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall March 26, 2024 Also sent via email to: aviv.meitalaviv@gmail.com Meital Aviv 1020 S. Hickory Street Santa Ana, CA. 92701 Subject: Address Assignment for a new Accessory Dwelling Unit located at 1020 South Hickory Street and (APN: 011-075-21) in Santa Ana, CA Dear Meital, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a new Accessory Dwelling Unit located at 1020 South Hickory Street and (APN: 011-075-21). Notice is hereby given that the following assigned address(es) shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address(es) to be Activated/Posted To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 667-2709 or by email at ASevilla@santa-ana.org. Sincerely, Alexis Sevilla Planning Technician Reviewed by: Jerry Guevara, Senior Planner 1022 S Hickory St 1/9/2025 Address Letter for 1020 S. Hickory Street Page 2 of 2 Exhibit A – Address Plan c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Alvaro Nunez, PBA Assistant Director and Code Enforcement Manager 1022 S Hickory St 1/9/2025 HEAT GAIN COEFFICIENT OF .23. MANUFACTURERS TO SUPPLY CERTIFICATE OF COMPLIANCE TO THE OWNER. SAFETY COMMISSION. 1. ALL NEW GLAZING SHALL COMPLY WITH STANDARDS OF THE U.S. CONSUMER PRODUCT NOTES: REQUIREMENTS OF TITLE 24 REPORT OR A CERTIFIED U-FACTOR OF .30 AND SOLAR 2. NEW GLAZED OPENING (WINDOWS & DOORS) SHALL BE LABELED TO INDICATE THE 3. THE NFRC TEMPORARY LABEL DISPLAYED ON THE WINDOWS MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED 4. 6. EXTERIOR DOORS SHALL MEET A MINIMUM 20 MINUTE FIRE RESISTANCE RATING WHEN TESTED ACCORDING TO NFPA 252. 5. EXTERIOR WINDOWS, WINDOW WALLS, GLAZED DOORS AND GLAZED OPENINGS WITHIN DOORS SHALL BE DUAL GLAZED WITH A MINIMUM OF ONE TEMPERED PANE DUAL GLAZING, OR BE GLASS BLOCK UNITS, OR BE 20 MINUTE FIRE-RATED OR MEET THE REQUIREMENTS OF SFM 12-7A-2. 3. THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN ACCORDANCE WITH ASTM E1300. SHEET CELL: 949-401-3370 INFO@YARDDES.COM Scale SHANI KRISPIN PR O J E C T N A M E : 10 2 0 S . H I C K O R Y S T . SA N T A A N A CA L I F O R N I A 9 2 7 0 1 DATE SH E E T T I T L E IRVINE, CA 92618 6 FOXCHASE YARD DESIGN PREPARED BY: AV I V R E S I D E N C E 01-A-000 1/8" = 1'-0" PR O P O S E D P L A N 02/14/2024 APPROVAL STAMP PROPOSED SITE PLAN SECTION 1 (POOL) GENERAL NOTES: BATHROOM NOTES CLOTHES DRYER NOTES PLUMBING NOTE FENCE ELEVATION (E) 1020 S. HICKORY STREET (N) 1022 S. HICKORY STREET EXHIBIT A - ADDRESS PLAN 1022 S Hickory St 1/9/2025 1022 S Hickory St 1/9/2025 STRUCTURAL CALCULATIONS PROJECT: 1020 S Hickory St., Santa Ana, CA 92701 JOB #23-572 11-07-24 BY: Shant Shahbaz 1022 S Hickory St 1/9/2025 Roof: D.L (psf)20 L.L (psf)20 Floor:Wall: D.L (psf)16 L.L (psf)15 10 L.L (psf)40 15 D.L. =Dead Load T.A = Tributary Area L.L = Live Load wD = (T.A.i * D.L.i) Roof Framing: L= Length wL = (T.A.i * L.L.i) L.L (psf)60 L.L (psf) Deck:Ceiling D.L (psf)16 D.L (psf) ←wD, wL RR (1) L (ft)10'Catilever 1' T.A. (ft)1.33 wD (lb/ft)27 wL (lb/ft)27 ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 10' ←D, wL CJ (1) L (ft)18' T.A. (ft)1.33 wD (lb/ft)13 wL (lb/ft)20 2 x 10 @ 16" O.C. (No.2)↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 18' ←D, wL RBM(1) L (ft)20.5'Catilever 1' T.A.roof (ft)9 wD 180 wL (lb/ft)180 3½ x 15 (Glu-Lam 26F-V2)↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 20.5' SPS ENGINEERING 818 747 7269 | shant.sps@gmail.com 1022 S Hickory St 1/9/2025 Roof Framing: ←wD, wL HDR(1) L (ft)6' T.A.roof (ft)10 (ft)9 wD (lb/ft)290 wL 335 ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 6' ←D, wL HDR(2) L (ft)3' T.A.roof (ft)7.5 wD (lb/ft)150 wL 150 3' ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ←D, wL HDR(3) L (ft)6' T.A.roof (ft)7.5 wD (lb/ft)150 wL 150 6' ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ←D, wL HDR(4) L (ft)6' T.A.roof (ft)7.5 wD (lb/ft)150 wL (lb/ft)150 ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 6' ←D, wL HDR(5) L (ft)12' T.A.roof (ft)3 wD (lb/ft)60 wL (lb/ft)60 (lbs)1940 (lbs)1940 ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 12' From RBM (1) @ 10' From RBM (1) @ 10' ENGINEERING 818 747 7269 | shant.sps@gmail.com 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RR1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-South No.2 850.0 850.0 1,350.0 520.0 1,200.0 440.0 180.0 525.0 28.720 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.0270, L = 0.0270 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.282: 1 Load Combination +D+L+H, LL Comb Run (L*) Span # where maximum occurs Span # 1 Location of maximum on span 4.475 ft 22.19 psi= = 1,075.25 psi 2x10Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L+H, LL Comb Run (LL) = = = 180.00 psi== Section used for this span 2x10 Maximum Shear Stress Ratio 0.123 : 1 8.246 ft= = 302.95 psi Maximum Deflection 2010 >=360 1618 Ratio =1032 >=240 Max Downward Transient Deflection 0.034 in 3188Ratio =>=360 Max Upward Transient Deflection -0.012 in Ratio = Max Downward Total Deflection 0.067 in Ratio =>=240 Max Upward Total Deflection -0.023 in fb: Actual F'b fv: Actual F'v Span: 2 : L Only, LL Comb Run (*L) Span: 2 : L Only, LL Comb Run (L*) Span: 1 : +D+L+H, LL Comb Run (L*) Span: 2 : +D+L+H, LL Comb Run (L*) .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu +D+H 0.0 0.00 0.00.0 1.00Length = 9.0 ft 1 0.155 0.068 0.90 1.100 1.151.00 1.00 0.27 149.6 967.7 0.10 162.01.00 11.11.00 1.00Length = 1.0 ft 2 0.008 0.068 0.90 1.100 1.151.00 1.00 0.01 7.6 967.7 0.01 162.01.00 11.11.00 1.00+D+L+H, LL Comb Run (*L)1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.136 0.063 1.00 1.100 1.151.00 1.00 0.26 145.9 1,075.3 0.10 180.01.00 11.31.00 1.00Length = 1.0 ft 2 0.014 0.063 1.00 1.100 1.151.00 1.00 0.03 15.1 1,075.3 0.01 180.01.00 11.31.00 1.00+D+L+H, LL Comb Run (L*)1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.282 0.122 1.00 1.100 1.151.00 1.00 0.54 302.9 1,075.3 0.20 180.01.00 22.01.00 1.00Length = 1.0 ft 2 0.007 0.122 1.00 1.100 1.151.00 1.00 0.01 7.6 1,075.3 0.01 180.01.00 22.01.00 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RR1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+D+L+H, LL Comb Run (LL)1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.278 0.123 1.00 1.100 1.151.00 1.00 0.53 299.2 1,075.3 0.21 180.01.00 22.21.00 1.00Length = 1.0 ft 2 0.014 0.123 1.00 1.100 1.151.00 1.00 0.03 15.1 1,075.3 0.01 180.01.00 22.21.00 1.00+D+Lr+H, LL Comb Run (*L)1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.111 0.049 1.25 1.100 1.151.00 1.00 0.27 149.6 1,344.1 0.10 225.01.00 11.11.00 1.00Length = 1.0 ft 2 0.006 0.049 1.25 1.100 1.151.00 1.00 0.01 7.6 1,344.1 0.01 225.01.00 11.11.00 1.00+D+Lr+H, LL Comb Run (L*)1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.111 0.049 1.25 1.100 1.151.00 1.00 0.27 149.6 1,344.1 0.10 225.01.00 11.11.00 1.00Length = 1.0 ft 2 0.006 0.049 1.25 1.100 1.151.00 1.00 0.01 7.6 1,344.1 0.01 225.01.00 11.11.00 1.00+D+Lr+H, LL Comb Run (LL)1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.111 0.049 1.25 1.100 1.151.00 1.00 0.27 149.6 1,344.1 0.10 225.01.00 11.11.00 1.00Length = 1.0 ft 2 0.006 0.049 1.25 1.100 1.151.00 1.00 0.01 7.6 1,344.1 0.01 225.01.00 11.11.00 1.00+D+S+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.121 0.054 1.15 1.100 1.151.00 1.00 0.27 149.6 1,236.5 0.10 207.01.00 11.11.00 1.00Length = 1.0 ft 2 0.006 0.054 1.15 1.100 1.151.00 1.00 0.01 7.6 1,236.5 0.01 207.01.00 11.11.00 1.00+D+0.750Lr+0.750L+H, LL Comb Run (*1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.109 0.050 1.25 1.100 1.151.00 1.00 0.26 146.8 1,344.1 0.10 225.01.00 11.21.00 1.00Length = 1.0 ft 2 0.010 0.050 1.25 1.100 1.151.00 1.00 0.02 13.3 1,344.1 0.01 225.01.00 11.21.00 1.00+D+0.750Lr+0.750L+H, LL Comb Run (L 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.197 0.086 1.25 1.100 1.151.00 1.00 0.47 264.6 1,344.1 0.18 225.01.00 19.31.00 1.00Length = 1.0 ft 2 0.006 0.086 1.25 1.100 1.151.00 1.00 0.01 7.6 1,344.1 0.01 225.01.00 19.31.00 1.00+D+0.750Lr+0.750L+H, LL Comb Run (L 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.195 0.086 1.25 1.100 1.151.00 1.00 0.47 261.8 1,344.1 0.18 225.01.00 19.41.00 1.00Length = 1.0 ft 2 0.010 0.086 1.25 1.100 1.151.00 1.00 0.02 13.3 1,344.1 0.01 225.01.00 19.41.00 1.00+D+0.750L+0.750S+H, LL Comb Run (*L 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.119 0.054 1.15 1.100 1.151.00 1.00 0.26 146.8 1,236.5 0.10 207.01.00 11.21.00 1.00Length = 1.0 ft 2 0.011 0.054 1.15 1.100 1.151.00 1.00 0.02 13.3 1,236.5 0.01 207.01.00 11.21.00 1.00+D+0.750L+0.750S+H, LL Comb Run (L*1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.214 0.093 1.15 1.100 1.151.00 1.00 0.47 264.6 1,236.5 0.18 207.01.00 19.31.00 1.00Length = 1.0 ft 2 0.006 0.093 1.15 1.100 1.151.00 1.00 0.01 7.6 1,236.5 0.01 207.01.00 19.31.00 1.00+D+0.750L+0.750S+H, LL Comb Run (LL 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.212 0.094 1.15 1.100 1.151.00 1.00 0.47 261.8 1,236.5 0.18 207.01.00 19.41.00 1.00Length = 1.0 ft 2 0.011 0.094 1.15 1.100 1.151.00 1.00 0.02 13.3 1,236.5 0.01 207.01.00 19.41.00 1.00+D+0.60W+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.087 0.039 1.60 1.100 1.151.00 1.00 0.27 149.6 1,720.4 0.10 288.01.00 11.11.00 1.00Length = 1.0 ft 2 0.004 0.039 1.60 1.100 1.151.00 1.00 0.01 7.6 1,720.4 0.01 288.01.00 11.11.00 1.00+D+0.750Lr+0.750L+0.450W+H, LL Comb 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.085 0.039 1.60 1.100 1.151.00 1.00 0.26 146.8 1,720.4 0.10 288.01.00 11.21.00 1.00Length = 1.0 ft 2 0.008 0.039 1.60 1.100 1.151.00 1.00 0.02 13.3 1,720.4 0.01 288.01.00 11.21.00 1.00+D+0.750Lr+0.750L+0.450W+H, LL Comb 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.154 0.067 1.60 1.100 1.151.00 1.00 0.47 264.6 1,720.4 0.18 288.01.00 19.31.00 1.00Length = 1.0 ft 2 0.004 0.067 1.60 1.100 1.151.00 1.00 0.01 7.6 1,720.4 0.01 288.01.00 19.31.00 1.00+D+0.750Lr+0.750L+0.450W+H, LL Comb 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.152 0.067 1.60 1.100 1.151.00 1.00 0.47 261.8 1,720.4 0.18 288.01.00 19.41.00 1.00Length = 1.0 ft 2 0.008 0.067 1.60 1.100 1.151.00 1.00 0.02 13.3 1,720.4 0.01 288.01.00 19.41.00 1.00+D+0.750L+0.750S+0.450W+H, LL Comb 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.085 0.039 1.60 1.100 1.151.00 1.00 0.26 146.8 1,720.4 0.10 288.01.00 11.21.00 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RR1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 1.0 ft 2 0.008 0.039 1.60 1.100 1.151.00 1.00 0.02 13.3 1,720.4 0.01 288.01.00 11.21.00 1.00+D+0.750L+0.750S+0.450W+H, LL Comb 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.154 0.067 1.60 1.100 1.151.00 1.00 0.47 264.6 1,720.4 0.18 288.01.00 19.31.00 1.00Length = 1.0 ft 2 0.004 0.067 1.60 1.100 1.151.00 1.00 0.01 7.6 1,720.4 0.01 288.01.00 19.31.00 1.00+D+0.750L+0.750S+0.450W+H, LL Comb 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.152 0.067 1.60 1.100 1.151.00 1.00 0.47 261.8 1,720.4 0.18 288.01.00 19.41.00 1.00Length = 1.0 ft 2 0.008 0.067 1.60 1.100 1.151.00 1.00 0.02 13.3 1,720.4 0.01 288.01.00 19.41.00 1.00+0.60D+0.60W+0.60H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.052 0.023 1.60 1.100 1.151.00 1.00 0.16 89.8 1,720.4 0.06 288.01.00 6.71.00 1.00Length = 1.0 ft 2 0.003 0.023 1.60 1.100 1.151.00 1.00 0.01 4.5 1,720.4 0.00 288.01.00 6.71.00 1.00+D+0.70E+0.60H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.087 0.039 1.60 1.100 1.151.00 1.00 0.27 149.6 1,720.4 0.10 288.01.00 11.11.00 1.00Length = 1.0 ft 2 0.004 0.039 1.60 1.100 1.151.00 1.00 0.01 7.6 1,720.4 0.01 288.01.00 11.11.00 1.00+D+0.750L+0.750S+0.5250E+H, LL Comb 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.085 0.039 1.60 1.100 1.151.00 1.00 0.26 146.8 1,720.4 0.10 288.01.00 11.21.00 1.00Length = 1.0 ft 2 0.008 0.039 1.60 1.100 1.151.00 1.00 0.02 13.3 1,720.4 0.01 288.01.00 11.21.00 1.00+D+0.750L+0.750S+0.5250E+H, LL Comb 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.154 0.067 1.60 1.100 1.151.00 1.00 0.47 264.6 1,720.4 0.18 288.01.00 19.31.00 1.00Length = 1.0 ft 2 0.004 0.067 1.60 1.100 1.151.00 1.00 0.01 7.6 1,720.4 0.01 288.01.00 19.31.00 1.00+D+0.750L+0.750S+0.5250E+H, LL Comb 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.152 0.067 1.60 1.100 1.151.00 1.00 0.47 261.8 1,720.4 0.18 288.01.00 19.41.00 1.00Length = 1.0 ft 2 0.008 0.067 1.60 1.100 1.151.00 1.00 0.02 13.3 1,720.4 0.01 288.01.00 19.41.00 1.00+0.60D+0.70E+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.052 0.023 1.60 1.100 1.151.00 1.00 0.16 89.8 1,720.4 0.06 288.01.00 6.71.00 1.00Length = 1.0 ft 2 0.003 0.023 1.60 1.100 1.151.00 1.00 0.01 4.5 1,720.4 0.00 288.01.00 6.71.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L+H, LL Comb Run (L*)1 0.0667 4.525 0.0000 0.000 +D+L+H, LL Comb Run (L*)2 0.0000 4.525 -0.0232 1.000 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.242 0.300 Max Upward from Load Combinations 0.242 0.300 Max Upward from Load Cases 0.122 0.150 Max Downward from all Load Conditio -0.002 Max Downward from Load Cases (Resis -0.002 +D+H 0.120 0.150 +D+L+H, LL Comb Run (*L)0.119 0.178 +D+L+H, LL Comb Run (L*)0.242 0.271 +D+L+H, LL Comb Run (LL)0.240 0.300 +D+Lr+H, LL Comb Run (*L)0.120 0.150 +D+Lr+H, LL Comb Run (L*)0.120 0.150 +D+Lr+H, LL Comb Run (LL)0.120 0.150 +D+S+H 0.120 0.150 +D+0.750Lr+0.750L+H, LL Comb Run (*0.119 0.171 +D+0.750Lr+0.750L+H, LL Comb Run (L 0.211 0.241 +D+0.750Lr+0.750L+H, LL Comb Run (L 0.210 0.262 +D+0.750L+0.750S+H, LL Comb Run (*L 0.119 0.171 +D+0.750L+0.750S+H, LL Comb Run (L*0.211 0.241 +D+0.750L+0.750S+H, LL Comb Run (LL 0.210 0.262 +D+0.60W+H 0.120 0.150 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RR1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS +D+0.750Lr+0.750L+0.450W+H, LL Comb 0.119 0.171 +D+0.750Lr+0.750L+0.450W+H, LL Comb 0.211 0.241 +D+0.750Lr+0.750L+0.450W+H, LL Comb 0.210 0.262 +D+0.750L+0.750S+0.450W+H, LL Comb 0.119 0.171 +D+0.750L+0.750S+0.450W+H, LL Comb 0.211 0.241 +D+0.750L+0.750S+0.450W+H, LL Comb 0.210 0.262 +0.60D+0.60W+0.60H 0.072 0.090 +D+0.70E+0.60H 0.120 0.150 +D+0.750L+0.750S+0.5250E+H, LL Comb 0.119 0.171 +D+0.750L+0.750S+0.5250E+H, LL Comb 0.211 0.241 +D+0.750L+0.750S+0.5250E+H, LL Comb 0.210 0.262 +0.60D+0.70E+H 0.072 0.090 D Only 0.120 0.150 L Only, LL Comb Run (*L)-0.002 0.029 L Only, LL Comb Run (L*)0.122 0.121 L Only, LL Comb Run (LL)0.120 0.150 H Only 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.24.07.08 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:CJ1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: HICKORY ST.ec6 CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-South No.2 850.0 850.0 1,350.0 520.0 1,200.0 440.0 180.0 525.0 28.720 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.0130, L = 0.020 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.697: 1 Load Combination +D+L+H Span # where maximum occurs Span # 1 Location of maximum on span 9.000 ft 29.53 psi= = 1,075.25 psi 2x10Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L+H = = = 180.00 psi== Section used for this span 2x10 Maximum Shear Stress Ratio 0.164 : 1 17.277 ft= = 749.77 psi Maximum Deflection 539 <360 327 Ratio =0 <240 Max Downward Transient Deflection 0.400 in 0 Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.660 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L+H n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu +D+H 0.0 0.00 0.00.0 1.00Length = 18.0 ft 1 0.305 0.072 0.90 1.100 1.151.00 1.00 0.53 295.4 967.7 0.11 162.01.00 11.61.00 1.00+D+L+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 18.0 ft 1 0.697 0.164 1.00 1.100 1.151.00 1.00 1.34 749.8 1,075.3 0.27 180.01.00 29.51.00 1.00+D+Lr+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 18.0 ft 1 0.220 0.052 1.25 1.100 1.151.00 1.00 0.53 295.4 1,344.1 0.11 225.01.00 11.61.00 1.00+D+S+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 18.0 ft 1 0.239 0.056 1.15 1.100 1.151.00 1.00 0.53 295.4 1,236.5 0.11 207.01.00 11.61.00 1.00+D+0.750Lr+0.750L+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.24.07.08 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:CJ1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: HICKORY ST.ec6 Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 18.0 ft 1 0.473 0.111 1.25 1.100 1.151.00 1.00 1.13 636.2 1,344.1 0.23 225.01.00 25.11.00 1.00+D+0.750L+0.750S+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 18.0 ft 1 0.514 0.121 1.15 1.100 1.151.00 1.00 1.13 636.2 1,236.5 0.23 207.01.00 25.11.00 1.00+D+0.60W+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 18.0 ft 1 0.172 0.040 1.60 1.100 1.151.00 1.00 0.53 295.4 1,720.4 0.11 288.01.00 11.61.00 1.00+D+0.750Lr+0.750L+0.450W+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 18.0 ft 1 0.370 0.087 1.60 1.100 1.151.00 1.00 1.13 636.2 1,720.4 0.23 288.01.00 25.11.00 1.00+D+0.750L+0.750S+0.450W+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 18.0 ft 1 0.370 0.087 1.60 1.100 1.151.00 1.00 1.13 636.2 1,720.4 0.23 288.01.00 25.11.00 1.00+0.60D+0.60W+0.60H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 18.0 ft 1 0.103 0.024 1.60 1.100 1.151.00 1.00 0.32 177.2 1,720.4 0.06 288.01.00 7.01.00 1.00+D+0.70E+0.60H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 18.0 ft 1 0.172 0.040 1.60 1.100 1.151.00 1.00 0.53 295.4 1,720.4 0.11 288.01.00 11.61.00 1.00+D+0.750L+0.750S+0.5250E+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 18.0 ft 1 0.370 0.087 1.60 1.100 1.151.00 1.00 1.13 636.2 1,720.4 0.23 288.01.00 25.11.00 1.00+0.60D+0.70E+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 18.0 ft 1 0.103 0.024 1.60 1.100 1.151.00 1.00 0.32 177.2 1,720.4 0.06 288.01.00 7.01.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L+H 1 0.6604 9.066 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.297 0.297 Max Upward from Load Combinations 0.297 0.297 Max Upward from Load Cases 0.180 0.180 +D+H 0.117 0.117 +D+L+H 0.297 0.297 +D+Lr+H 0.117 0.117 +D+S+H 0.117 0.117 +D+0.750Lr+0.750L+H 0.252 0.252 +D+0.750L+0.750S+H 0.252 0.252 +D+0.60W+H 0.117 0.117 +D+0.750Lr+0.750L+0.450W+H 0.252 0.252 +D+0.750L+0.750S+0.450W+H 0.252 0.252 +0.60D+0.60W+0.60H 0.070 0.070 +D+0.70E+0.60H 0.117 0.117 +D+0.750L+0.750S+0.5250E+H 0.252 0.252 +0.60D+0.70E+H 0.070 0.070 D Only 0.117 0.117 L Only 0.180 0.180 H Only 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RBM1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design DF/DF 26F-V2 2,600.0 2,600.0 1,850.0 650.0 2,000.0 1,060.0 265.0 1,350.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity 1,800.0 ksi 950.0 ksi Ebend- yy Eminbend - yy Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.180, L = 0.180 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.600: 1 Load Combination +D+L+H, LL Comb Run (L*) Span # where maximum occurs Span # 1 Location of maximum on span 9.696 ft 88.22 psi= = 2,600.00 psi 3.5x15Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L+H, LL Comb Run (LL) = = = 265.00 psi== Section used for this span 3.5x15 Maximum Shear Stress Ratio 0.333 : 1 18.302 ft= = 1,560.32 psi Maximum Deflection 490 >=360 391 Ratio =246 >=240 Max Downward Transient Deflection 0.300 in 779Ratio =>=360 Max Upward Transient Deflection -0.049 in Ratio = Max Downward Total Deflection 0.598 in Ratio =>=240 Max Upward Total Deflection -0.097 in fb: Actual F'b fv: Actual F'v Span: 2 : L Only, LL Comb Run (*L) Span: 2 : L Only, LL Comb Run (L*) Span: 1 : +D+L+H, LL Comb Run (L*) Span: 2 : +D+L+H, LL Comb Run (L*) .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCV rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu +D+H 0.0 0.00 0.00.0 1.00Length = 19.50 ft 1 0.333 0.185 0.90 1.000 1.001.00 1.00 8.51 778.1 2,340.0 1.54 238.51.00 44.11.00 1.00Length = 1.0 ft 2 0.004 0.185 0.90 1.000 1.001.00 1.00 0.09 8.2 2,340.0 0.18 238.51.00 44.11.00 1.00+D+L+H, LL Comb Run (*L)1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.298 0.167 1.00 1.000 1.001.00 1.00 8.47 774.0 2,600.0 1.55 265.01.00 44.21.00 1.00Length = 1.0 ft 2 0.006 0.167 1.00 1.000 1.001.00 1.00 0.18 16.5 2,600.0 0.36 265.01.00 44.21.00 1.00+D+L+H, LL Comb Run (L*)1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.600 0.332 1.00 1.000 1.001.00 1.00 17.07 1,560.3 2,600.0 3.08 265.01.00 88.11.00 1.00Length = 1.0 ft 2 0.003 0.332 1.00 1.000 1.001.00 1.00 0.09 8.2 2,600.0 0.18 265.01.00 88.11.00 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RBM1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCV rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+D+L+H, LL Comb Run (LL)1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.599 0.333 1.00 1.000 1.001.00 1.00 17.02 1,556.2 2,600.0 3.09 265.01.00 88.21.00 1.00Length = 1.0 ft 2 0.006 0.333 1.00 1.000 1.001.00 1.00 0.18 16.5 2,600.0 0.36 265.01.00 88.21.00 1.00+D+Lr+H, LL Comb Run (*L)1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.239 0.133 1.25 1.000 1.001.00 1.00 8.51 778.1 3,250.0 1.54 331.31.00 44.11.00 1.00Length = 1.0 ft 2 0.003 0.133 1.25 1.000 1.001.00 1.00 0.09 8.2 3,250.0 0.18 331.31.00 44.11.00 1.00+D+Lr+H, LL Comb Run (L*)1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.239 0.133 1.25 1.000 1.001.00 1.00 8.51 778.1 3,250.0 1.54 331.31.00 44.11.00 1.00Length = 1.0 ft 2 0.003 0.133 1.25 1.000 1.001.00 1.00 0.09 8.2 3,250.0 0.18 331.31.00 44.11.00 1.00+D+Lr+H, LL Comb Run (LL)1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.239 0.133 1.25 1.000 1.001.00 1.00 8.51 778.1 3,250.0 1.54 331.31.00 44.11.00 1.00Length = 1.0 ft 2 0.003 0.133 1.25 1.000 1.001.00 1.00 0.09 8.2 3,250.0 0.18 331.31.00 44.11.00 1.00+D+S+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.260 0.145 1.15 1.000 1.001.00 1.00 8.51 778.1 2,990.0 1.54 304.81.00 44.11.00 1.00Length = 1.0 ft 2 0.003 0.145 1.15 1.000 1.001.00 1.00 0.09 8.2 2,990.0 0.18 304.81.00 44.11.00 1.00+D+0.750Lr+0.750L+H, LL Comb Run (*1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.238 0.133 1.25 1.000 1.001.00 1.00 8.48 775.0 3,250.0 1.55 331.31.00 44.21.00 1.00Length = 1.0 ft 2 0.004 0.133 1.25 1.000 1.001.00 1.00 0.16 14.4 3,250.0 0.31 331.31.00 44.21.00 1.00+D+0.750Lr+0.750L+H, LL Comb Run (L 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.420 0.233 1.25 1.000 1.001.00 1.00 14.93 1,364.8 3,250.0 2.70 331.31.00 77.11.00 1.00Length = 1.0 ft 2 0.003 0.233 1.25 1.000 1.001.00 1.00 0.09 8.2 3,250.0 0.18 331.31.00 77.11.00 1.00+D+0.750Lr+0.750L+H, LL Comb Run (L 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.419 0.233 1.25 1.000 1.001.00 1.00 14.89 1,361.7 3,250.0 2.70 331.31.00 77.21.00 1.00Length = 1.0 ft 2 0.004 0.233 1.25 1.000 1.001.00 1.00 0.16 14.4 3,250.0 0.32 331.31.00 77.21.00 1.00+D+0.750L+0.750S+H, LL Comb Run (*L 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.259 0.145 1.15 1.000 1.001.00 1.00 8.48 775.0 2,990.0 1.55 304.81.00 44.21.00 1.00Length = 1.0 ft 2 0.005 0.145 1.15 1.000 1.001.00 1.00 0.16 14.4 2,990.0 0.31 304.81.00 44.21.00 1.00+D+0.750L+0.750S+H, LL Comb Run (L*1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.456 0.253 1.15 1.000 1.001.00 1.00 14.93 1,364.8 2,990.0 2.70 304.81.00 77.11.00 1.00Length = 1.0 ft 2 0.003 0.253 1.15 1.000 1.001.00 1.00 0.09 8.2 2,990.0 0.18 304.81.00 77.11.00 1.00+D+0.750L+0.750S+H, LL Comb Run (LL 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.455 0.253 1.15 1.000 1.001.00 1.00 14.89 1,361.7 2,990.0 2.70 304.81.00 77.21.00 1.00Length = 1.0 ft 2 0.005 0.253 1.15 1.000 1.001.00 1.00 0.16 14.4 2,990.0 0.32 304.81.00 77.21.00 1.00+D+0.60W+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.187 0.104 1.60 1.000 1.001.00 1.00 8.51 778.1 4,160.0 1.54 424.01.00 44.11.00 1.00Length = 1.0 ft 2 0.002 0.104 1.60 1.000 1.001.00 1.00 0.09 8.2 4,160.0 0.18 424.01.00 44.11.00 1.00+D+0.750Lr+0.750L+0.450W+H, LL Comb 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.186 0.104 1.60 1.000 1.001.00 1.00 8.48 775.0 4,160.0 1.55 424.01.00 44.21.00 1.00Length = 1.0 ft 2 0.003 0.104 1.60 1.000 1.001.00 1.00 0.16 14.4 4,160.0 0.31 424.01.00 44.21.00 1.00+D+0.750Lr+0.750L+0.450W+H, LL Comb 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.328 0.182 1.60 1.000 1.001.00 1.00 14.93 1,364.8 4,160.0 2.70 424.01.00 77.11.00 1.00Length = 1.0 ft 2 0.002 0.182 1.60 1.000 1.001.00 1.00 0.09 8.2 4,160.0 0.18 424.01.00 77.11.00 1.00+D+0.750Lr+0.750L+0.450W+H, LL Comb 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.327 0.182 1.60 1.000 1.001.00 1.00 14.89 1,361.7 4,160.0 2.70 424.01.00 77.21.00 1.00Length = 1.0 ft 2 0.003 0.182 1.60 1.000 1.001.00 1.00 0.16 14.4 4,160.0 0.32 424.01.00 77.21.00 1.00+D+0.750L+0.750S+0.450W+H, LL Comb 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.186 0.104 1.60 1.000 1.001.00 1.00 8.48 775.0 4,160.0 1.55 424.01.00 44.21.00 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RBM1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCV rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 1.0 ft 2 0.003 0.104 1.60 1.000 1.001.00 1.00 0.16 14.4 4,160.0 0.31 424.01.00 44.21.00 1.00+D+0.750L+0.750S+0.450W+H, LL Comb 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.328 0.182 1.60 1.000 1.001.00 1.00 14.93 1,364.8 4,160.0 2.70 424.01.00 77.11.00 1.00Length = 1.0 ft 2 0.002 0.182 1.60 1.000 1.001.00 1.00 0.09 8.2 4,160.0 0.18 424.01.00 77.11.00 1.00+D+0.750L+0.750S+0.450W+H, LL Comb 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.327 0.182 1.60 1.000 1.001.00 1.00 14.89 1,361.7 4,160.0 2.70 424.01.00 77.21.00 1.00Length = 1.0 ft 2 0.003 0.182 1.60 1.000 1.001.00 1.00 0.16 14.4 4,160.0 0.32 424.01.00 77.21.00 1.00+0.60D+0.60W+0.60H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.112 0.062 1.60 1.000 1.001.00 1.00 5.11 466.9 4,160.0 0.93 424.01.00 26.51.00 1.00Length = 1.0 ft 2 0.001 0.062 1.60 1.000 1.001.00 1.00 0.05 4.9 4,160.0 0.11 424.01.00 26.51.00 1.00+D+0.70E+0.60H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.187 0.104 1.60 1.000 1.001.00 1.00 8.51 778.1 4,160.0 1.54 424.01.00 44.11.00 1.00Length = 1.0 ft 2 0.002 0.104 1.60 1.000 1.001.00 1.00 0.09 8.2 4,160.0 0.18 424.01.00 44.11.00 1.00+D+0.750L+0.750S+0.5250E+H, LL Comb 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.186 0.104 1.60 1.000 1.001.00 1.00 8.48 775.0 4,160.0 1.55 424.01.00 44.21.00 1.00Length = 1.0 ft 2 0.003 0.104 1.60 1.000 1.001.00 1.00 0.16 14.4 4,160.0 0.31 424.01.00 44.21.00 1.00+D+0.750L+0.750S+0.5250E+H, LL Comb 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.328 0.182 1.60 1.000 1.001.00 1.00 14.93 1,364.8 4,160.0 2.70 424.01.00 77.11.00 1.00Length = 1.0 ft 2 0.002 0.182 1.60 1.000 1.001.00 1.00 0.09 8.2 4,160.0 0.18 424.01.00 77.11.00 1.00+D+0.750L+0.750S+0.5250E+H, LL Comb 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.327 0.182 1.60 1.000 1.001.00 1.00 14.89 1,361.7 4,160.0 2.70 424.01.00 77.21.00 1.00Length = 1.0 ft 2 0.003 0.182 1.60 1.000 1.001.00 1.00 0.16 14.4 4,160.0 0.32 424.01.00 77.21.00 1.00+0.60D+0.70E+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.112 0.062 1.60 1.000 1.001.00 1.00 5.11 466.9 4,160.0 0.93 424.01.00 26.51.00 1.00Length = 1.0 ft 2 0.001 0.062 1.60 1.000 1.001.00 1.00 0.05 4.9 4,160.0 0.11 424.01.00 26.51.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L+H, LL Comb Run (L*)1 0.5983 9.804 0.0000 0.000 +D+L+H, LL Comb Run (L*)2 0.0000 9.804 -0.0971 1.000 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 3.505 3.879 Max Upward from Load Combinations 3.505 3.879 Max Upward from Load Cases 1.755 1.940 Max Downward from all Load Conditio -0.005 Max Downward from Load Cases (Resis -0.005 +D+H 1.750 1.940 +D+L+H, LL Comb Run (*L)1.746 2.124 +D+L+H, LL Comb Run (L*)3.505 3.695 +D+L+H, LL Comb Run (LL)3.501 3.879 +D+Lr+H, LL Comb Run (*L)1.750 1.940 +D+Lr+H, LL Comb Run (L*)1.750 1.940 +D+Lr+H, LL Comb Run (LL)1.750 1.940 +D+S+H 1.750 1.940 +D+0.750Lr+0.750L+H, LL Comb Run (*1.747 2.078 +D+0.750Lr+0.750L+H, LL Comb Run (L 3.067 3.256 +D+0.750Lr+0.750L+H, LL Comb Run (L 3.063 3.394 +D+0.750L+0.750S+H, LL Comb Run (*L 1.747 2.078 +D+0.750L+0.750S+H, LL Comb Run (L*3.067 3.256 +D+0.750L+0.750S+H, LL Comb Run (LL 3.063 3.394 +D+0.60W+H 1.750 1.940 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RBM1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS +D+0.750Lr+0.750L+0.450W+H, LL Comb 1.747 2.078 +D+0.750Lr+0.750L+0.450W+H, LL Comb 3.067 3.256 +D+0.750Lr+0.750L+0.450W+H, LL Comb 3.063 3.394 +D+0.750L+0.750S+0.450W+H, LL Comb 1.747 2.078 +D+0.750L+0.750S+0.450W+H, LL Comb 3.067 3.256 +D+0.750L+0.750S+0.450W+H, LL Comb 3.063 3.394 +0.60D+0.60W+0.60H 1.050 1.164 +D+0.70E+0.60H 1.750 1.940 +D+0.750L+0.750S+0.5250E+H, LL Comb 1.747 2.078 +D+0.750L+0.750S+0.5250E+H, LL Comb 3.067 3.256 +D+0.750L+0.750S+0.5250E+H, LL Comb 3.063 3.394 +0.60D+0.70E+H 1.050 1.164 D Only 1.750 1.940 L Only, LL Comb Run (*L)-0.005 0.185 L Only, LL Comb Run (L*)1.755 1.755 L Only, LL Comb Run (LL)1.750 1.940 H Only 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.24.07.08 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:HDR1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: HICKORY ST.ec6 CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-South No.2 850.0 850.0 1,350.0 520.0 1,200.0 440.0 180.0 525.0 28.720 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.290, L = 0.3350 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.770: 1 Load Combination +D+L+H Span # where maximum occurs Span # 1 Location of maximum on span 3.000 ft 54.25 psi= = 850.00 psi 6x8Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L+H = = = 180.00 psi== Section used for this span 6x8 Maximum Shear Stress Ratio 0.301 : 1 0.000 ft= = 654.55 psi Maximum Deflection 1700 <360 911 Ratio =0 <240 Max Downward Transient Deflection 0.042 in 0 Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.079 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L+H n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu +D+H 0.0 0.00 0.00.0 1.00Length = 6.0 ft 1 0.397 0.155 0.90 1.000 1.001.00 1.00 1.31 303.7 765.0 0.69 162.01.00 25.21.00 1.00+D+L+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.770 0.301 1.00 1.000 1.001.00 1.00 2.81 654.5 850.0 1.49 180.01.00 54.21.00 1.00+D+Lr+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.286 0.112 1.25 1.000 1.001.00 1.00 1.31 303.7 1,062.5 0.69 225.01.00 25.21.00 1.00+D+S+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.311 0.122 1.15 1.000 1.001.00 1.00 1.31 303.7 977.5 0.69 207.01.00 25.21.00 1.00+D+0.750Lr+0.750L+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.24.07.08 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:HDR1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: HICKORY ST.ec6 Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 6.0 ft 1 0.533 0.209 1.25 1.000 1.001.00 1.00 2.44 566.8 1,062.5 1.29 225.01.00 47.01.00 1.00+D+0.750L+0.750S+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.580 0.227 1.15 1.000 1.001.00 1.00 2.44 566.8 977.5 1.29 207.01.00 47.01.00 1.00+D+0.60W+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.223 0.087 1.60 1.000 1.001.00 1.00 1.31 303.7 1,360.0 0.69 288.01.00 25.21.00 1.00+D+0.750Lr+0.750L+0.450W+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.417 0.163 1.60 1.000 1.001.00 1.00 2.44 566.8 1,360.0 1.29 288.01.00 47.01.00 1.00+D+0.750L+0.750S+0.450W+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.417 0.163 1.60 1.000 1.001.00 1.00 2.44 566.8 1,360.0 1.29 288.01.00 47.01.00 1.00+0.60D+0.60W+0.60H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.134 0.052 1.60 1.000 1.001.00 1.00 0.78 182.2 1,360.0 0.42 288.01.00 15.11.00 1.00+D+0.70E+0.60H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.223 0.087 1.60 1.000 1.001.00 1.00 1.31 303.7 1,360.0 0.69 288.01.00 25.21.00 1.00+D+0.750L+0.750S+0.5250E+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.417 0.163 1.60 1.000 1.001.00 1.00 2.44 566.8 1,360.0 1.29 288.01.00 47.01.00 1.00+0.60D+0.70E+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.134 0.052 1.60 1.000 1.001.00 1.00 0.78 182.2 1,360.0 0.42 288.01.00 15.11.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L+H 1 0.0790 3.022 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.875 1.875 Max Upward from Load Combinations 1.875 1.875 Max Upward from Load Cases 1.005 1.005 +D+H 0.870 0.870 +D+L+H 1.875 1.875 +D+Lr+H 0.870 0.870 +D+S+H 0.870 0.870 +D+0.750Lr+0.750L+H 1.624 1.624 +D+0.750L+0.750S+H 1.624 1.624 +D+0.60W+H 0.870 0.870 +D+0.750Lr+0.750L+0.450W+H 1.624 1.624 +D+0.750L+0.750S+0.450W+H 1.624 1.624 +0.60D+0.60W+0.60H 0.522 0.522 +D+0.70E+0.60H 0.870 0.870 +D+0.750L+0.750S+0.5250E+H 1.624 1.624 +0.60D+0.70E+H 0.522 0.522 D Only 0.870 0.870 L Only 1.005 1.005 H Only 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:HDR2-4 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-South No.2 850.0 850.0 1,350.0 520.0 1,200.0 440.0 180.0 525.0 28.720 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.150, L = 0.150 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.687: 1 Load Combination +D+L+H Span # where maximum occurs Span # 1 Location of maximum on span 3.000 ft 38.11 psi= = 850.00 psi 6x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L+H = = = 180.00 psi== Section used for this span 6x6 Maximum Shear Stress Ratio 0.212 : 1 0.000 ft= = 584.22 psi Maximum Deflection 0 <360 748 Ratio =0 <240 Max Downward Transient Deflection 0.048 in 1497Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.096 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L+H n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu +D+H 0.0 0.00 0.00.0 1.00Length = 6.0 ft 1 0.382 0.118 0.90 1.000 1.001.00 1.00 0.68 292.1 765.0 0.38 162.01.00 19.11.00 1.00+D+L+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.687 0.212 1.00 1.000 1.001.00 1.00 1.35 584.2 850.0 0.77 180.01.00 38.11.00 1.00+D+Lr+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.275 0.085 1.25 1.000 1.001.00 1.00 0.68 292.1 1,062.5 0.38 225.01.00 19.11.00 1.00+D+S+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.299 0.092 1.15 1.000 1.001.00 1.00 0.68 292.1 977.5 0.38 207.01.00 19.11.00 1.00+D+0.750Lr+0.750L+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:HDR2-4 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 6.0 ft 1 0.481 0.148 1.25 1.000 1.001.00 1.00 1.18 511.2 1,062.5 0.67 225.01.00 33.31.00 1.00+D+0.750L+0.750S+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.523 0.161 1.15 1.000 1.001.00 1.00 1.18 511.2 977.5 0.67 207.01.00 33.31.00 1.00+D+0.60W+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.215 0.066 1.60 1.000 1.001.00 1.00 0.68 292.1 1,360.0 0.38 288.01.00 19.11.00 1.00+D+0.750Lr+0.750L+0.450W+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.376 0.116 1.60 1.000 1.001.00 1.00 1.18 511.2 1,360.0 0.67 288.01.00 33.31.00 1.00+D+0.750L+0.750S+0.450W+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.376 0.116 1.60 1.000 1.001.00 1.00 1.18 511.2 1,360.0 0.67 288.01.00 33.31.00 1.00+0.60D+0.60W+0.60H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.129 0.040 1.60 1.000 1.001.00 1.00 0.41 175.3 1,360.0 0.23 288.01.00 11.41.00 1.00+D+0.70E+0.60H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.215 0.066 1.60 1.000 1.001.00 1.00 0.68 292.1 1,360.0 0.38 288.01.00 19.11.00 1.00+D+0.750L+0.750S+0.5250E+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.376 0.116 1.60 1.000 1.001.00 1.00 1.18 511.2 1,360.0 0.67 288.01.00 33.31.00 1.00+0.60D+0.70E+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.129 0.040 1.60 1.000 1.001.00 1.00 0.41 175.3 1,360.0 0.23 288.01.00 11.41.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L+H 1 0.0962 3.022 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.900 0.900 Max Upward from Load Combinations 0.900 0.900 Max Upward from Load Cases 0.450 0.450 +D+H 0.450 0.450 +D+L+H 0.900 0.900 +D+Lr+H 0.450 0.450 +D+S+H 0.450 0.450 +D+0.750Lr+0.750L+H 0.788 0.788 +D+0.750L+0.750S+H 0.788 0.788 +D+0.60W+H 0.450 0.450 +D+0.750Lr+0.750L+0.450W+H 0.788 0.788 +D+0.750L+0.750S+0.450W+H 0.788 0.788 +0.60D+0.60W+0.60H 0.270 0.270 +D+0.70E+0.60H 0.450 0.450 +D+0.750L+0.750S+0.5250E+H 0.788 0.788 +0.60D+0.70E+H 0.270 0.270 D Only 0.450 0.450 L Only 0.450 0.450 H Only 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:HDR5 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-South No.2 850.0 850.0 1,350.0 520.0 1,200.0 440.0 180.0 525.0 28.720 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.060, L = 0.060 k/ft Point Load : D = 1.940, L = 1.940 k @ 10.0 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.893: 1 Load Combination +D+L+H Span # where maximum occurs Span # 1 Location of maximum on span 9.985 ft 91.14 psi= = 850.00 psi 6x12Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L+H = = = 180.00 psi== Section used for this span 6x12 Maximum Shear Stress Ratio 0.506 : 1 11.080 ft= = 758.65 psi Maximum Deflection 0 <360 689 Ratio =0 <240 Max Downward Transient Deflection 0.104 in 1378Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.209 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L+H n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu +D+H 0.0 0.00 0.00.0 1.00Length = 12.0 ft 1 0.496 0.281 0.90 1.000 1.001.00 1.00 3.83 379.3 765.0 1.92 162.01.00 45.61.00 1.00+D+L+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 12.0 ft 1 0.893 0.506 1.00 1.000 1.001.00 1.00 7.66 758.7 850.0 3.84 180.01.00 91.11.00 1.00+D+Lr+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 12.0 ft 1 0.357 0.203 1.25 1.000 1.001.00 1.00 3.83 379.3 1,062.5 1.92 225.01.00 45.61.00 1.00+D+S+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 12.0 ft 1 0.388 0.220 1.15 1.000 1.001.00 1.00 3.83 379.3 977.5 1.92 207.01.00 45.61.00 1.00+D+0.750Lr+0.750L+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1022 S Hickory St 1/9/2025 Wood Beam LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:HDR5 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 12.0 ft 1 0.625 0.354 1.25 1.000 1.001.00 1.00 6.71 663.8 1,062.5 3.36 225.01.00 79.71.00 1.00+D+0.750L+0.750S+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 12.0 ft 1 0.679 0.385 1.15 1.000 1.001.00 1.00 6.71 663.8 977.5 3.36 207.01.00 79.71.00 1.00+D+0.60W+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 12.0 ft 1 0.279 0.158 1.60 1.000 1.001.00 1.00 3.83 379.3 1,360.0 1.92 288.01.00 45.61.00 1.00+D+0.750Lr+0.750L+0.450W+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 12.0 ft 1 0.488 0.277 1.60 1.000 1.001.00 1.00 6.71 663.8 1,360.0 3.36 288.01.00 79.71.00 1.00+D+0.750L+0.750S+0.450W+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 12.0 ft 1 0.488 0.277 1.60 1.000 1.001.00 1.00 6.71 663.8 1,360.0 3.36 288.01.00 79.71.00 1.00+0.60D+0.60W+0.60H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 12.0 ft 1 0.167 0.095 1.60 1.000 1.001.00 1.00 2.30 227.6 1,360.0 1.15 288.01.00 27.31.00 1.00+D+0.70E+0.60H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 12.0 ft 1 0.279 0.158 1.60 1.000 1.001.00 1.00 3.83 379.3 1,360.0 1.92 288.01.00 45.61.00 1.00+D+0.750L+0.750S+0.5250E+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 12.0 ft 1 0.488 0.277 1.60 1.000 1.001.00 1.00 6.71 663.8 1,360.0 3.36 288.01.00 79.71.00 1.00+0.60D+0.70E+H 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 12.0 ft 1 0.167 0.095 1.60 1.000 1.001.00 1.00 2.30 227.6 1,360.0 1.15 288.01.00 27.31.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L+H 1 0.2089 6.569 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.367 3.953 Max Upward from Load Combinations 1.367 3.953 Max Upward from Load Cases 0.683 1.977 +D+H 0.683 1.977 +D+L+H 1.367 3.953 +D+Lr+H 0.683 1.977 +D+S+H 0.683 1.977 +D+0.750Lr+0.750L+H 1.196 3.459 +D+0.750L+0.750S+H 1.196 3.459 +D+0.60W+H 0.683 1.977 +D+0.750Lr+0.750L+0.450W+H 1.196 3.459 +D+0.750L+0.750S+0.450W+H 1.196 3.459 +0.60D+0.60W+0.60H 0.410 1.186 +D+0.70E+0.60H 0.683 1.977 +D+0.750L+0.750S+0.5250E+H 1.196 3.459 +0.60D+0.70E+H 0.410 1.186 D Only 0.683 1.977 L Only 0.683 1.977 H Only 1022 S Hickory St 1/9/2025 Wood Column LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:--None-- SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 .Code References Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Wood Section Name 4x8Analysis Method : 13Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb +900 900 psi 1350 625 180 575 31.21 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1600 580 1600 580 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.20 Use Cr : Repetitive ? Kf : Built-up columns 1.0 Exact Width 3.50 in Exact Depth 7.250 in Area 25.375 in^2 Ix 111.148 in^4 Iy 25.904 in^4 Wood Grading/Manuf.Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.050 1600 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.30 x-x Bending y-y Bending ksi No Minimum Basic ABOUT Y-Y Axis: Luy = 13 ft, Ky = 1.0 ABOUT X-X Axis: Lux = 13 ft, Kx = 1.0 Column Buckling Condition: .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 71.496 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 13.0 ft, D = 2.210, L = 2.310 k .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.7833 Location of max.above base 0.0 ft Applied Axial 4.592 k Applied Mx 0.0 k-ft Load Combination +D+L Load Combination +0.60D Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 0.0 psi 288.0Allowable Shear psi 0.0 : 1 Bending Compression Tension Location of max.above base 13.0 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp Only, fc/Fc' Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.0 in at 0.0 ft above base for load combination :n/a Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 230.992 psi Other Factors used to calculate allowable stresses . . . for load combination :n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosCDCLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus Load Combination Results D Only 0.900 PASS PASS0.0 0.0 13.0 ft0.180 ft0.3911 +D+L 1.000 PASS PASS0.0 0.0 13.0 ft0.163 ft0.7833 +D+0.750L 1.250 PASS PASS0.0 0.0 13.0 ft0.131 ft0.6791 +0.60D 1.600 PASS PASS0.0 0.0 13.0 ft0.103 ft0.230 . k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis Reaction Axial Reaction @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My - End Moments Mx - End Moments D Only 2.281 +D+L 4.591 +D+0.750L 4.014 1022 S Hickory St 1/9/2025 Wood Column LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:--None-- SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis Reaction Axial Reaction @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My - End Moments Mx - End Moments +0.60D 1.369 L Only 2.310 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000 ftftinin0.000 +D+L 0.0000 0.000 0.000 ftftinin0.000 +D+0.750L 0.0000 0.000 0.000 ftftinin0.000 +0.60D 0.0000 0.000 0.000 ftftinin0.000 L Only 0.0000 0.000 0.000 ftftinin0.000 .Sketches 1022 S Hickory St 1/9/2025 ASCE 7-16 Seismic Base Shear LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:Seismic Base Shear Analysis SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 Risk Category ASCE 7-16, Page 4, Table 1.5-1 Calculations per ASCE 7-16 "II" : All Buildings and other structures except those listed as Category I, III, and IV Risk Category of Building or Other Structure : Seismic Importance Factor =1 ASCE 7-16, Page 5, Table 1.5-2 Specific Description: EARTHQUAKE Gridded Ss & S1values from ASCE 7-16 ASCE 7-16 11.4.2 Longitude =117.862 deg West Location :Santa Ana, CA 92701 Latitude =33.747 deg North Max. Ground Motions, 5% Damping : S =1.289 Longitude =117.860 deg West S Latitude =33.750 g, 0.2 sec response deg North S 0.45961 g, 1.0 sec response= Conforms to ASCE 7 Section 12.8.1.3: Regular structure with period of 0.5 s or less, SDS limited to max of 0.7*SDS or 1.0 for calculation of Cs. For the closest datapoint grid location . . . Site Class, Site Coeff. and Design Category Classification:ASCE 7-16 Table 20.3-1"D" : Shear Wave Velocity 600 to 1,200 ft/sec =D Site Coefficients Fa & Fv ASCE 7-16 Table 11.4-1 & 11.4-2 (using straight-line interpolation from table values) Fa =1.20 Fv =1.84 Maximum Considered Earthquake Acceleration ASCE 7-16 Eq. 11.4-1S = Fa * Ss 1.547=MS S = Fv * S1 =0.846M1 ASCE 7-16 Eq. 11.4-2 Design Spectral Acceleration ASCE 7-16 Eq. 11.4-3S = S * 2/3 =1.031DSMS =0.564 ASCE 7-16 Eq. 11.4-4S = S * 2/3D1M1 Seismic Design Category ASCE 7-16 Table 11.6-1 & -2=D (By Default per 11.4.3) Resisting System ASCE 7-16 Table 12.2-1 Basic Seismic Force Resisting System . . .Bearing Wall Systems 15.Light-frame (wood) walls sheathed w/wood structural panels rated for shear resistance. NOTE! See ASCE 7-16 for all applicable footnotes. Building height Limits :Response Modification Coefficient " R "=6.50 Category "A & B" Limit:No LimitSystem Overstrength Factor " Wo "=3.00 Category "C" Limit:No LimitDeflection Amplification Factor " Cd "=4.00 Category "D" Limit:Limit = 65 Category "E" Limit:Limit = 65 Category "F" Limit:Limit = 65 Lateral Force Procedure ASCE 7-16 Section 12.8.2 Equivalent Lateral Force Procedure The "Equivalent Lateral Force Procedure" is being used according to the provisions of ASCE 7-16 12.8 Use ASCE 12.8-7Determine Building Period Structure Type for Building Period Calculation :All Other Structural Systems " Ct " value 0.020= " x " value " hn " : Height from base to highest level =16.0 ft " Ta " Approximate fundemental period using Eq. 12.8-7 : 8.000"TL" : Long-period transition period per ASCE 7-16 Maps 22-14 -> 22-17 sec Ta = Ct * (hn ^ x) =0.160 0.75 sec = Building Period " Ta " Calculated from Approximate Method selected=0.160 1022 S Hickory St 1/9/2025 ASCE 7-16 Seismic Base Shear LIC# : KW-06019339, Build:20.23.08.30 SPS Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:Seismic Base Shear Analysis SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: HICKORY ST.ec6 " Cs " Response Coefficient ASCE 7-16 Section 12.8.1.1 S : Short Period Design Spectral Response 1.031 " R " : Response Modification Factor 6.50 " I " : Seismic Importance Factor =1 0.154From Eq. 12.8-2, Preliminary Cs = 0.542From Eq. 12.8-3 & 12.8-4 , Cs need not exceed = From Eq. 12.8-5 & 12.8-6, Cs not be less than =0.044 DS =Cs : Seismic Response Coefficient =0.1538User has selected ASCE 12.8.1.3 : Regular structure, Less than 5 Stories and with T <<= 0.5 sec, SO Ss <= 1.5 for Cs calculation = = Seismic Base Shear ASCE 7-16 Section 12.8.1 W ( see Sum Wi below ) =0.00 kCs =0.1538 from 12.8.1.1 Seismic Base Shear V = Cs * W =0.00 k Vertical Distribution of Seismic Forces ASCE 7-16 Section 12.8.3 " k " : hx exponent based on Ta =1.00 Table of building Weights by Floor Level... Wi : Weight Hi : Height (Wi * Hi^k)Cvx Fx=Cvx * V Sum Story Shear Sum Story MomentLevel # Sum Wi =0.00 k Total Base Shear =0.00 k Base Moment = 0.00 k-ftSum Wi * Hi = 0.0 k-ft Diaphragm Forces : Seismic Design Category "B" to "F"ASCE 7-16 12.10.1.1 Level #Wi Fi Fpx : MaxFpx : CalcdSum Fi Sum Wi Fpx Dsgn. ForceFpx : Min Wpx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Weight at level of diaphragm and other structure elements attached to it. Fi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Design Lateral Force applied at the level. Sum Fi . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Sum of "Lat. Force" of current level plus all levels above 0.20 * S * I * WpxMIN Req'd Force @ Level . . . . . . . . . .DS DSMAX Req'd Force @ Level . . . . . . . . . .0.40 * S * I * Wpx Fpx : Design Force @ Level . . . . . . . . . .Wpx * SUM(x->n) Fi / SUM(x->n) wi, x = Current level, n = Top Level 1022 S Hickory St 1/9/2025 LT i i r r r r r=1.3 5.40 psf Lateral Analysis: ENGINEERING 818 747 7269 | shant.sps@gmail.com 1022 S Hickory St 1/9/2025 Line A: LT s V =325.0 (lbs)2nd ν =72 (lb/ft)RM =504 s Line B: T s V =2429 (lbs)OM =3430 (lbs) OM = v * H ν =286 (lb/ft)v = V/L RM =1428 (lbs) RM = 14*Ls Line C: T s V =1404 (lbs)OM =936 (lbs) OM = v * H ν =78 (lb/ft)v = V/L RM =3024 (lbs) RM = 14*Ls Line 1: T s V =2699 (lbs)OM =2399 (lbs) OM = v * H ν =300 (lb/ft)v = V/L RM =1008 (lbs) RM = 14*Ls r r Roof Lateral Analysis: (1st Floor Walls) r ENGINEERING 818 747 7269 | shant.sps@gmail.com 1022 S Hickory St 1/9/2025 Line 2: LT s V =2699 (lbs)OM =508 (lbs) OM = v * H ν =64 (lb/ft)v = V/L RM =4760 (lbs) RM = 14*Ls Roof Lateral Analysis: (1st Floor Walls) ENGINEERING 818 747 7269 | shant.sps@gmail.com 1022 S Hickory St 1/9/2025 G E O M A X E N G I N E E R I N G, I N C. GEOLOGY ● SOILS INSPECTIONS ● TESTING 7340 FLORENCE AVE., SUITE 229 DOWNEY, CA 90240 PH: 562.806.2173 FAX: 562.806.2369 FINAL SOILS ENGINEERING INVESTIGATION REPORT PROPOSED ONE-STORY ADDITIONAL DWELLING UNIT (A.D.U.) 1022 S. HICKORY STREET SANTA ANA, CALIFORNIA PROJECT No.: GE24033 DATE: MAY 21, 2024 PREPARED FOR: MRS. MEITAL AVIV 1022 S. HICKORY STREET SANTA ANA, CALIFORNIA 92701 1022 S Hickory St 1/9/2025 1022 S. Hickory Street GE24033 Santa Ana, CA May 21, 2024 Page 2 of 14 GEOMAX Engineering, Inc. FINAL SOILS ENGINEERING INVESTIGATION REPORT PROPOSED ONE-STORY ADU 1022 S. HICKORY STREET SANTA ANA, CALIFORNIA PROJECT No.: GE24033 DATE: MAY 21, 2024 INTRODUCTION This report presents the results of a soil engineering investigation performed on the property. The purpose of the investigation was to determine the soils parameters applicable to the design and construction of the additional dwelling unit. Based on the findings, the soil conditions at the subject site are suitable for the construction of the proposed improvements provided the recommendations included herein are incorporated into their design and construction. 1022 S Hickory St 1/9/2025 1022 S. Hickory Street GE24033 Santa Ana, CA May 21, 2024 Page 3 of 14 GEOMAX Engineering, Inc. SCOPE The scope of this investigation included the following items: 1. Inspected site conditions. 2. Performed exploratory work involving three hand-dug test borings to determine the types of earth materials present and to obtain samples. 3. Reviewed a preliminary site plan prepared by Shani Krispin Yard Design dated April 10, 2024. 4. Laboratory testing of soils samples to determine their physical characteristics. 5. Reviewed U.S. Geological Survey, “Official Map of Seismic Hazard Zones, Tustin Quadrangle”. 6. Reviewed California Geological Survey, “Guidelines for Evaluation and Mitigation Seismic Hazards in California, Special Publication 117A” 7. Reviewed U.S. Geological Survey Seismic Design Website “ATC Hazards by Location” 8. Reviewed ASCE/SE17-16 “Minimum Design and Loads and Associated Criteria for Building and Other Structures Associated Criteria for Building and Other Structures” 9. Analyzed data, formulated conclusions and recommendations, and prepared the report. 1022 S Hickory St 1/9/2025 1022 S. Hickory Street GE24033 Santa Ana, CA May 21, 2024 Page 4 of 14 GEOMAX Engineering, Inc. PROPOSED IMPROVEMENTS The preliminary site plan provided (reference # 3) shows that the proposed improvements include a one-story additional dwelling unit (A.D.U.) to be located on the vacant, relatively-flat area south of the existing dwelling. (Plate 1). SITE CONDITIONS The subject site is located north of McFadden Avenue and west of Halladay Street in the City of Santa Ana (Figure 1). The property is a relatively-flat, rectangular-shaped lot 70 feet wide by 108 feet long. The site is occupied by a one-story, single-family dwelling with a detached 2-car garage, concrete walkways, planters and lawns. A concrete driveway along the north side provides access from the street to the existing improvements. The site is bounded along the west side and on portions of the north and south sides by 6-foot high concrete block walls. Drainage is by semi-controlled sheet flow towards the street. The surrounding developments are single-family dwellings. 1022 S Hickory St 1/9/2025 1022 S Hickory St 1/9/2025 1022 S. Hickory Street GE24033 Santa Ana, CA May 21, 2024 Page 5 of 14 GEOMAX Engineering, Inc. FIELD EXPLORATION On April 26, 2024, three exploratory borings were dug with hand-held tools to a maximum depth of 8 feet. The earth materials encountered were logged and classified using the visual and tactile field identification procedures of the Unified Soil Classification System. Undisturbed 2.5-inch diameter core samples were obtained for laboratory testing. The earth materials encountered are described in the Earth Materials Section and on the logs of the borings included in the Appendix. The locations of the exploratory sites are shown on Plate 1. EARTH MATERIALS The earth materials encountered in the exploratory locations entirely consist of native sandy clays which are moist to slightly moist, stiff to very stiff and light to dark brown. The earth materials encountered are described graphically on the logs of the borings in the Appendix (Plates 2 thru 4). 1022 S Hickory St 1/9/2025 1022 S. Hickory Street GE24033 Santa Ana, CA May 21, 2024 Page 6 of 14 GEOMAX Engineering, Inc. LABORATORY TESTS Laboratory tests were performed on typical native soils samples. Field moisture content, saturated moisture content, dry unit weight and direct shear strength characteristics were determined from these tests. Direct Shear These tests were performed on representative samples of the native soils that were saturated at least 24 hours under a normal load prior to application of the shear load. Each sample was sheared at a constant rate of displacement of 0.05 inches per minute in accordance with the consolidated-undrained shear test procedure. The shear strength values determined by these tests are shown graphically in the Appendix (Plates 5 and 6). 1022 S Hickory St 1/9/2025 1022 S. Hickory Street GE24033 Santa Ana, CA May 21, 2024 Page 7 of 14 GEOMAX Engineering, Inc. CONCLUSIONS AND RECOMMENDATIONS The site is considered geotechnically suitable for the construction of the proposed additional dwelling unit provided the recommendations herein are considered in the design and followed during construction. Foundations The proposed one-story additional dwelling unit shall be supported on continuous footings placed into stiff native soils The bearing capacity for continuous footings with a minimum width of 15 inches and a minimum depth of 18 inches is 1,500 psf for native soils. The bearing value may be increased 20 percent for each additional foot of depth or width to a maximum of 2,400 psf. The bearing capacity allowed is for the total of dead and frequently applied live loads and may be increased by one-third for short duration wind and seismic loading. 1022 S Hickory St 1/9/2025 1022 S. Hickory Street GE24033 Santa Ana, CA May 21, 2024 Page 8 of 14 GEOMAX Engineering, Inc. Lateral Design Resistance to lateral loads may be derived from the skin frictional forces acting at the base of footings and by passive pressure. The friction coefficient for use with dead load forces is 0.25 for native soils. The unit passive pressure for the first foot of depth using both internal frictional and cohesive shear strength components for the first foot of depth is 300 psf for native soils. This value maybe increased 50 percent for each additional foot of depth to a maximum of 3,000 pcf for native soils. Thee passive and skin frictional components are combined, the passive components should be reduced by a factor of one-third. The passive pressure allowed is for the total of dead and frequently applied live loads and may be increased by one- third for short duration wind and seismic loading. Settlement Settlement of the foundation is expected to occur immediately upon initial load application. Maximum settlement is expected to be less than ½-inch and differential settlement is expected to be less than ¼-inch provided all foundations are supported as recommended. 1022 S Hickory St 1/9/2025 1022 S. Hickory Street GE24033 Santa Ana, CA May 21, 2024 Page 9 of 14 GEOMAX Engineering, Inc. Expansive Soils The native soils are sandy clays. Although no actual expansion index test was performed, the sandy clayey soils are considered to be medium-to highly-expansive. Therefore. footings into native soils shall be provided with two, # 4 re-bars at top and bottom, and slabs on-grade and concrete pavements shall be reinforced with # 4 re- bars spaced at 12 inches on center each way. Sub-grade soils for slabs should be saturated for 24 hours prior to placing concrete. Liquefaction Potential The Seismic Hazard Map of the Tustin Quadrangle (reference # 5) shows that the subject site is located within an area susceptible to soil liquefaction. However, the proposed one-story additional dwelling unit is exempt from the liquefaction requirements per the State of California Public Resources Code, Section 2621.6 (Seismic Hazard Mapping Act). Therefore, special recommendations to mitigate the potential of soil liquefaction are not necessary. Hydro-collapse The phenomenon of hydro-collapse affects mostly granular soils that are transported and deposited by a fast, storm flow typical of deserts that drained rapidly without full saturation. The alluvial soils within the subject site and its vicinity are not subject to hydro-collapse. 1022 S Hickory St 1/9/2025 1022 S. Hickory Street GE24033 Santa Ana, CA May 21, 2024 Page 10 of 14 GEOMAX Engineering, Inc. Tsunami The site is located approximately 98 feet above sea level. Based on this, the California Emergency Management Agency describes the site as not within a tsunami or seische hazard zone. Seismic Coefficients The proposed structure shall be designed in accordance with the provisions presented in document ASCE/SEI 7-16 “Minimum Design Loads and Associated Criteria for Building and Other Structures”, and in Chapter 16A, Section 1613A Earthquake Loads of the 2022 California Building Code. The seismic design values below have been obtained using the United States Geological Survey (USGS) Design Maps for the Seismic Design Values for Buildings (reference # 7, Plates 7 and 8). Coordinates: 33.73513 N and -117.86082 W Occupancy Category: II (Table 1604.5) Site Class: (D) Native Soils (Table 1613.5.2 and Section 1623.5) Mapped Spectral Accelerations: Ss = 1.28 (g) Short Period (0.2 s) (Fig. 1613A.3.1) S1 = 0.46 (g) One-second Period (Fig. 1613A.3.1) Site Coefficients: Fa = 1.0 Short Period (0.2 s) ASCE/SEI 7-16 (Table 11.4.1 (1) Fv = 1.7 One-second Period) ASCE/SEI 7-16 (Table 11.4-2 (2) 1022 S Hickory St 1/9/2025 1022 S. Hickory Street GE24033 Santa Ana, CA May 21, 2024 Page 11 of 14 GEOMAX Engineering, Inc. Spectral Response Accelerations: SMS = 1.28 (g) Short Period (0.2 s) (Eq. 16A-37) SM1 = 0.78 (g) One-second Period) (Eq. 16A-38) Design Accelerations: SDS = 0.86 (g) Short Period (0.2 s) (Eq. 16A-39) SD1 = 0.52 (g) One-second Period) (Eq. 16A-40) Seismic Design Category: D ASCE/SEI 7-16 (Section 11.6) Short-Period Transition period TS= (SD1/SDS) = 0.60 s ZPA-Transition period T0= (0.2 XSD1/SDS) = 0.12 s The southern California region can be subject to heavy shaking as a result of moderate to major earthquakes with a magnitude of 6 or greater. The use of the seismic coefficients herein above are intended to prevent loss of life and to minimize but not entirely eliminate structural damage. Moreover, major foundation problems are not anticipated as a result of earthquake-induced liquefaction, fault ground rupture or displacement and settlement provided the proposed foundation system is constructed as recommended with the limitations mentioned here. 1022 S Hickory St 1/9/2025 1022 S. Hickory Street GE24033 Santa Ana, CA May 21, 2024 Page 12 of 14 GEOMAX Engineering, Inc. Slabs On-Grade and Concrete Pavements Slabs on-grade and concrete pavements should consist of 4 inches of concrete reinforced with # 4 re-bars spaced at 12 inches on center each way entirely supported on native soil. Slabs on-grade and concrete pavements on cut/fill transition areas are not allowed. Concrete slabs that are to be covered with flooring should be underlain by a plastic vapor barrier (a vapor barrier is not required for slabs-on-grade for garages, parking areas and/or concrete pavements). Per Section 4.505.2.1 of the 2022 California Green Building Standards Code, a 4-inch thick base of ½-inch or larger clean aggregate base materials shall be provided with a vapor barrier in direct contact with concrete and a concrete mix design, which will address bleeding, shrinkage, and curling, shall be used. This base materials layer will protect the plastic sheet while the concrete is being placed. The sub-grade materials should be thoroughly- saturated prior to casting concrete. Drainage Pad and roof drainage should be collected and conveyed to a Low Impact Development System (LID) via non-erodible conduits. Drainage should not be allowed to pond against the footings. 1022 S Hickory St 1/9/2025 1022 S. Hickory Street GE24033 Santa Ana, CA May 21, 2024 Page 13 of 14 GEOMAX Engineering, Inc. Inspections and Approval All footing excavations should be inspected and approved by this firm prior to placing forms and re-bars. Approval by the City Inspector may also be required. Please advise this office at least 24 hours prior to any required inspection or compaction testing. Limitations This report has been prepared for the exclusive use of MrS. Meital Aviv for planning purposes. Once final plans are prepared, this office should review the plans that must be in conformance with our recommendations. It is her responsibility or her representative to assure that the information and recommendations contained herein are made available to the designers and contractors of this project. This report is subject to review and approval by the Building Official. This report is based on the information obtained from exploratory borings and sampling locations using generally-accepted soils engineering practices. However, conditions can be expected to vary between points of exploration. 1022 S Hickory St 1/9/2025 6+LFNRU\6WUHHW*( 6DQWD$QD&$  0D\ 3DJHRI *(20$;(QJLQHHULQJ,QF 1RZDUUDQW\H[SUHVVHGRULPSOLHGLVPDGHRULQWHQGHGLQFRQQHFWLRQZLWKWKLV UHSRUWRUE\DQ\RWKHURUDORUZULWWHQVWDWHPHQW$Q\OLDELOLW\LQFRQQHFWLRQKHUHLQVKDOO QRWH[FHHGWKHIHHVIRUWKHLQYHVWLJDWLRQ 7KHRSSRUWXQLW\WREHRISURIHVVLRQDOVHUYLFHLVVLQFHUHO\DSSUHFLDWHG3OHDVH FDOOLI\RXKDYHDQ\TXHVWLRQVFRQFHUQLQJWKLVUHSRUW  5HVSHFWIXOO\VXEPLWWHG *HRPD[(QJLQHHULQJ,QF   0DQXHO$(VSLQR      +HFWRU0HGLQD  &KLHI(QJLQHHU     3URMHFW0DQDJHU 5&(&         ([S    0$(+0HP      $WWDFKPHQWV$SSHQGL[ZLWK3ODWHV  0DQXHO Q   &KLH QHHU   +HFWRU0HGLQ  3UR HFW0  1022 S Hickory St 1/9/2025 1022 S Hickory St 1/9/2025 1022 S Hickory St 1/9/2025 1022 S Hickory St 1/9/2025 1022 S Hickory St 1/9/2025 1022 S Hickory St 1/9/2025 1022 S Hickory St 1/9/2025 1022 S Hickory St 1/9/2025                                    !"##$      %&'()*+,-.(/'01.,67##  8 89#!768:<<!<=6<#68"66!>?7>#>@9> #7#@"7="#769F6>F=>!6#G K !"6?QQR4V'BN& M&4)(1E01.,6#>< W XY K  Z  [7#\7@=> W XY K  Z  [67\6#><  "K        ]  ^  "K        ]  7>=? _K  K Y]   7#^ _K  K Y]   67@>/'01.,V'BN& M&4)(1E01.,^  K Y Y 6  K     7#^  K     67 abcdefghfifjklkmnoopqr srgoti PLATE 7 1022 S Hickory St 1/9/2025                  # "$  %  &%')#* ++% %$   &)%'*.#  $/0 %   &)1 ++2 3   2%'  %  5 &)%'# ++% %$   &%'  $/0 %   &)1 ++2 3   2%'  %  5 &%'   %  5 &'#C>9A 89:9 DE FE7 :9G=9B> C@H ;>C>9 I: =IBC= CJ9@AJ9@>; >I >89 KC=<9; I: C@H A9=?@9C>?I@ =?@9; JCA9 A<:?@L :IB9;;O P;9:; ;8I<=A BI@G?:J C@H I<>N<> IM>C?@9A G:IJ >8?; >II= Q?>8 >89 =IBC= R<>8I:?>H SCK?@L T<:?;A?B>?I@ M9> >89 R7V SCWC:A; MH XIBC>?I@ Q9M;?>9 Q?== @I> M9 <NAC>9A >I ;<NNI:> RYVZ [\]]O ^?@A I<> Q8HO 5 +2 / ,  52 % 4% h+ 5% %  /% i+% % +5  + j !  % % %%  +% %%  2 !/  %  /   %/  + %      2 %    i  5  % 2j %+2   +2 +2 %  / % %% %  /%    / % k  %/   %%%j /5 3  j   %+%  / %   l  %/ %%%      2 /+2 /% i+% ,%%  /   /% i+% %%  +2 %  %/ % ,%  /  2  5 +2 / 5 +  +% % %+  +   5   + +2 m   /   PLATE 8 1022 S Hickory St 1/9/2025 1022 S Hickory St 1/9/2025 1022 S Hickory St 1/9/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area to Total Resulting Stories: Area Added in Past 2 Years Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed (PR400-402) Fire Sprinkler   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR 795 795 1022 S Hickory St 1/9/2025