Loading...
HomeMy WebLinkAbout1011 W Second St - PlanT-1 GARCIA RESIDENCE SHEET PROPERTY OWNER: JUAN GARCIA (949) 627-2074 REV DATE DESCRIPTION 10/16/23A THE RE SHALL BE NO CHANGES OR D EVIATION ON THESE PLANS WI THOUT THE CONSENT OF PLAN AND PERMIT INC. NOTES AND DETAIL S ON THE DRAWI NGS SHALL TAKE PREC EDENCE OVER G ENERAL NOTES AND TYPICAL DETAILS. WHE RE NO DE TAILS SH OWN OR NOTED ON THE DR AWINGS, TH E DE TAILS SHALL BE THE SAME AS FOR OTHER SI MILAR WORK.CONTRACT OR SH ALL VERIFY ALL PLANS, EXISTING DIMENSIONS AND FIELD C ONDITI ONS ON THE J OB SITE AND SHALL IMMEDIATELY NOTI FY TO PLAN AND P ERMIT INC ANY DISCREPANC IES I N WRI TING PRIOR TO THE COMMENCEMENT OF ANY WORK OR BE RE SPONSIBLE FOR SA TH E S E D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F P L A N A N D P E R M I T I N C A N D S H A L L N O T B E U S E D I N C O N N E C T I O N W I T H A N Y O T H E R W O R K E X C E P T B Y A G R E E M E N T W I T H P L A N A N D P E R M I T I N C . B Y U S I N G T H E S E P L A N S , T H E U S E R A G R E E S T O R E L E A S E P L A N A N D P E R M I T I N C F R O M A N Y A N D A L L C L A I M S , L I A B I L I T I E S , S U I T S , A N D D E M A N D S O N A C C O U N T O F A N Y I N J U R Y , D A M A G E O R L O S S O R P E R S O N S O R P R O P E R T Y , I N C L U D I N G I N J U R Y O R D E A T H , O R E C O N O M I C L O S S E S , A R I S I N G O U T O F T H E U S E O F T H E S E P L A N S . SKETCH FOR REVIEW 11/17/23 B 90PD FOR APPROVALC 01/02/240 100PD FOR SUBMITTAL 10/31/23 90PD FOR REVIEW PROPERTY ADDRESS: 1011 W 2ND ST, SANTA ANA, CA 92703 PLAN AND PERMIT INC. ARCHITECTURAL DESIGN SERVICES 9891 IRVINE CENTER DR #200 IRVINE, CA 92618 (714)-715-0923 biz@planandpermit.com LOCATION QR CODE: STATE OF CAL IFORNIA EXP. DATE L I C E NS E D A R C H I T E C T C - 34643 06/30/2025 SIGNATURE PAUL SAN GEMINO TITLE SHEET BUILDING INFORMATION: ADDRESS: NUMBER OF STORIES: YEAR BUILDING WAS CONSTRUCTED:1903 APN:40516325 LOT AREA:6,250 SF TYPE OF CONSTRUCTION:V-B OCCUPANCY GROUP:R-3/U FIRE SPRINKLER:NO 1011 W 2ND ST, SANTA ANA, CA 92703 TYPE:SINGLE FAMILY RESIDENTIAL 1 EXISTING GARAGE AREA TO BE DEMOLISHED: ±401 SF PROPOSED GARAGE AREA: NOTE: NO WORK WILL BE PERFORMED IN THE RIGHT-OF-WAY. SHEET INDEX: THE CITY OF SANTA ANA SCOPE OF WORK: W 2ND ST 1011 W 2ND ST,SANTA ANA, CA 92703 1 SITE PLAN DEMOLISHING AND REBUILDING THE EXISTING GARAGE LIKE FOR LIKE & REMOVING THE EXISTING SHED. SITE NOT TO SCALE SITE APPROX. P/L ±50.00' NOT TO SCALE PROPERTY ADDRESS: AP P R O X . P / L ± 1 2 5 . 0 0 ' (E) LANDSCAPING (E) PATIO COVER (N) GARAGE, ±401 SF 0 8' 8' 16' 18" = 1'-0" ADJACENT PROPERTY NOT IN SCOPE OF WORK ADJACENT PROPERTY NOT IN SCOPE OF WORK (E) DRIVEWAY PARCEL MAP AERIAL VIEWVICINITY MAP A-2 ELEVATIONS & DETAIL T-1 TITLE SHEET GN-2 GENERAL NOTES GN-1 GENERAL NOTES U-1 A-1 FLOOR & ROOF PLAN GN-3 GENERAL NOTES UTILITY PLAN & DETAILS S1.01 CONSTRUCTION NOTES (BY OTHERS) CONSTRUCTION NOTES (BY OTHERS) S1.21 TYPICAL S.O.G AND FOUNDATION DETAILS (BY OTHERS) S1.22 S1.23 S1.24 S2.01 TYPICAL WOOD DETAILS (BY OTHERS) S0.01 S0.02 TYPICAL WALL DETAILS (BY OTHERS) TYPICAL WOOD DETAILS (BY OTHERS) TYPICAL WOOD DETAILS (BY OTHERS) CEILING, ROOF & FOUNDATION PLAN (BY OTHERS) AP P R O X . P / L ± 1 2 5 . 0 0 ' ADJACENT PROPERTY NOT IN SCOPE OF WORK APPROX. P/L ±50.00' (E) HARD SCAPING (E) FRONT PORCH (E) EAVE LINE (E) GATE.TYP. (E) POST.TYP. (E) STAIR.TYP. ±401 SF CODE COMPLIANCE DESIGN SHALL COMPLY WITH THE 2022 CRC, CBC, CGBSC, CEC, CMC, CPC AND CALIFORNIA ENERGY CODE AS AMENDED BY CITY ORDINANCE. (E) SHED TO BE REMOVED (E) GARAGE TO BE DEMOLISHED AND REBUILDING LIKE FOR LIKE (E) GATE (E) SITE WALL.TYP. (E) MAN GATE (E) CAR GATE.TYP. (E) CMU WALL & RAILING.TYP. (E) GATE.TYP.TO REMAIN (N) 1 HR FIRE RATED WALL (E) SITE TREE.TYP. Know what'sbelow. Call before you dig. USA North California and Nevada Call Two Working Days Before You Dig! 811 / 800-227-2600 EXISTING FLOOR AREA:±1,008 SF PROPOSED BUILDING COVERAGE:±1930 SF PROPOSED COVERAGE/LOT :±%30.8 ±165 SFEXISTING STORAGE AREA: ±250 SFEXISTING PATIO COVER AREA : ±106 SFEXISTING FRONT PORCH AREA: (E) SITE WALL.TYP. (E) SITE WALL. A-3 SECTIONS, DETAILS & DOOR/WINDOW SCHEDULE SITE COVER SHEET (BY OTHERS)CS.01 *5/7.214Ā+4803560Ā-*(Ā *%,,$,'Ȁ",!)Ȁ$ "Ȁ'*+&Ȁ'+'#%#&+,,## Bldg #101120893 APPROVALS: PLNG - F. Arias PUBLIC WORKS - Y. Soto 1011 W Second St 5/1/2025 (E) GARAGE (N) GARAGE 8' CLG DS DS A-1 GARCIA RESIDENCE SHEET PROPERTY OWNER: JUAN GARCIA (949) 627-2074 REV DATE DESCRIPTION 10/16/23A THERE SHALL BE NO CHANGES OR DEVIATION ON THESE PLANS WITHOUT TH E CONSENT OF PLAN AND PERMIT IN C. NOTES AND DETAILS ON THE DRAW INGS SHALL TAKE PRECEDENCE OVER GENERAL NOTE S AND TYPICAL DETAILS. WHERE NO DETAILS SH OWN OR NOTED ON THE DRAWINGS, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK.CONTRACTOR SHALL VERI FY ALL PLANS, EXISTING DIMENSIO NS AND FIELD CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY TO PLAN AND PERMIT INC ANY DISCREPANCIES IN WR ITING PRIOR TO THE COMMENCEMENT OF ANY WOR K OR BE RESPONSIBLE FOR SAME. TH E S E D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F P L A N A N D P E R M I T I N C A N D S H A L L N O T B E U S E D I N C O N N E CT I O N W I T H A N Y O T H E R W O R K E X C E P T B Y A G R E E M E N T W I T H P L A N A N D P E R M I T I N C . B Y U S I N G T H E S E P L A N S , T H E U S E R A G R E E S T O R E L E A S E P L A N A ND P E R M I T I N C F R O M A N Y A N D A L L C L A I M S , L I A B I L I T I E S , S U I T S , A N D D E M A N D S O N A C C O U N T O F A N Y I N J U R Y , D A M A G E O R L O S S O R P E R S O N S O R P RO P E R T Y , I N C L U D I N G I N J U R Y O R D E A T H , O R E C O N O M I C L O S S E S , A R I S I N G O U T O F T H E U S E O F T H E S E P L A N S . SKETCH FOR REVIEW 11/17/23 B 90PD FOR APPROVALC 01/02/240 100PD FOR SUBMITTAL 10/31/23 90PD FOR REVIEW PROPERTY ADDRESS: 1011 W 2ND ST, SANTA ANA, CA 92703 PLAN AND PERMIT INC. ARCHITECTURAL DESIGN SERVICES 9891 IRVINE CENTER DR #200 IRVINE, CA 92618 (714)-715-0923 biz@planandpermit.com LOCATION QR CODE: STATE OF CAL IFORNIAEXP. DATE L I C E NS E D A R CHI T E C T C - 34643 06/30/2025 SIGNATURE PAUL SAN GEMINO 1 EXISTING GARAGE PLAN (DEMO PLAN)2 PROPOSED GARAGE PLAN 3 EXISTING ROOF PLAN (DEMO PLAN)4 PROPOSED ROOF PLAN FLOOR & ROOF PLANS 04' 4'8' 1 4" = 1'-0" 04' 4' 8' 1 4" = 1'-0" 04' 4'8' 1 4" = 1'-0" 04' 4'8' 14" = 1'-0" BUILDING SECTION DESIGNATION SHEET NUMBER BUILDING ELEVATION DESIGNATION SHEET NUMBER LEGEND: = = = DETAIL REFERENCE SHEET NUMBER =FLOOR ELEVATION CHANGE WINDOW DESIGNATION DOOR DESIGNATION ROOM CEILING HEIGHT, FLOORING = = == =WALL SECTION REFERENCE SHEET NUMBER = = = SMOKE ALARM SEALED BATTERY PHOTOELECTRIC SMOKE DETECTOR WITH IONIZATION SENSOR, INTERCONNECTED AND HARD-WIRED,(UL 217). CARBON MONOXIDE ALARM SEALED BATTERY PHOTOELECTRIC, INTERCONNECTED AND HARD-WIRED,(UL 2034). =NEW WALL 2X4==WALL TO STAY WALL TO DEMO= REVISION DESIGNATION= =NEW WALL 2X6= =1HR FIRE RATED WALL 2X4= ==1HR FIRE RATED WALL 2X6EXISTING 1HR FIRE RATED COMMON WALL=ROOM 0" CLG, FLOORING MAX.7 3 4" 2 A-3 2 A-2 4:12 PITCH4:12 PITCH 4:12 PITCH4:12 PITCH 4 A-2 1 A-2 5 A-2 7 A-2 3 A-2 8 A-2 8 A-2 (E) WALL TO BE REMOVED.TYP. (E) GARAGE DOOR TO BE REMOVED %2 S L O P E MAX.7 3 4" (N) GARAGE DOOR (E) ROOF TO BE REMOVED (N) ROOF W/ ASPHALT SHINGLE, LANDMARK, CLASS A, COLOR TO BE MATCHED W/ (E) MAIN DWELLING ROOF, ICC-ES-ESR-1389 & ESR-3537. (OR APPROVED EQUAL) (N) 1 HR FIRE RATED WALL (N) RAIN GUTTER AND DOWNSPOUT.TYP. SEE SHEET D-1 x ROOF VENT CALCULATIONS: 1/150TH OF AREA REQUIRED AT ROOF x ATTIC AREA : 401 SF @ GARAGE: 401 SF / 150 SF = 2.7 SF REQUIRED 2 x GABLE VENT: 2 x 3 = 6 SF PROVIDED ROOF NOTE: a. A MINIMUM OF 1" AIRSPACE SHALL BE PROVIDED BETWEEN INSULATION AND ROOF SHEATHING. OPENINGS SHALL BE PLACED SO AS TO PROVIDE CROSS VENTILATION OF THE ATTIC SPACE. b. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE ATTIC AREA. c. VENT OPENINGS SHALL BE COVERED WITH NON-COMBUSTIBLE CORROSION RESISTANT, METAL WIRE MESH OR OTHER MATERIALS HAVING OPENINGS 1/16” MINIMUM TO 1/8” MAXIMUM (IRVINE MUNICIPAL CODE 5-9-402(N)). d. 50% OF THE REQUIRED VENTILATION AREA MUST BE LOCATED AT LEAST 3 FT. ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE PROVIDED BY EAVE OR CORNICE VENTS. e. WHERE THE RATIO OF 1/300 IS USED TO VENT THE ATTICS, NOT LESS THAN 40% BUT NOT MORE THAN 50% OF THE VENTS SHALL BE LOCATED NOT MORE THAN 3 FT. BELOW THE RIDGE. %2 S L O P E 1 A-3           1011 W Second St 5/1/2025 A-2 GARCIA RESIDENCE SHEET PROPERTY OWNER: JUAN GARCIA (949) 627-2074 REV DATE DESCRIPTION 10/16/23A THERE SHALL BE NO CHANGES OR DEVIATION ON THESE PLANS WITHOUT TH E CONSENT OF PLAN AND PERMIT IN C. NOTES AND DETAILS ON THE DRAW INGS SHALL TAKE PRECEDENCE OVER GENERAL NOTE S AND TYPICAL DETAILS. WHERE NO DETAILS SH OWN OR NOTED ON THE DRAWINGS, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK.CONTRACTOR SHALL VERI FY ALL PLANS, EXISTING DIMENSIO NS AND FIELD CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY TO PLAN AND PERMIT INC ANY DISCREPANCIES IN WR ITING PRIOR TO THE COMMENCEMENT OF ANY WOR K OR BE RESPONSIBLE FOR SAME. TH E S E D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F P L A N A N D P E R M I T I N C A N D S H A L L N O T B E U S E D I N C O N N E CT I O N W I T H A N Y O T H E R W O R K E X C E P T B Y A G R E E M E N T W I T H P L A N A N D P E R M I T I N C . B Y U S I N G T H E S E P L A N S , T H E U S E R A G R E E S T O R E L E A S E P L A N A ND P E R M I T I N C F R O M A N Y A N D A L L C L A I M S , L I A B I L I T I E S , S U I T S , A N D D E M A N D S O N A C C O U N T O F A N Y I N J U R Y , D A M A G E O R L O S S O R P E R S O N S O R P RO P E R T Y , I N C L U D I N G I N J U R Y O R D E A T H , O R E C O N O M I C L O S S E S , A R I S I N G O U T O F T H E U S E O F T H E S E P L A N S . SKETCH FOR REVIEW 11/17/23 B 90PD FOR APPROVALC 01/02/240 100PD FOR SUBMITTAL 10/31/23 90PD FOR REVIEW PROPERTY ADDRESS: 1011 W 2ND ST, SANTA ANA, CA 92703 PLAN AND PERMIT INC. ARCHITECTURAL DESIGN SERVICES 9891 IRVINE CENTER DR #200 IRVINE, CA 92618 (714)-715-0923 biz@planandpermit.com LOCATION QR CODE: STATE OF CAL IFORNIAEXP. DATE L I C E NS E D A R CHI T E C T C - 34643 06/30/2025 SIGNATURE PAUL SAN GEMINO ELEVATIONS & DETAIL 1 EXISTING SOUTH ELEVATION 04' 4' 8' 14" = 1'-0" 2 PROPOSED SOUTH ELEVATION 04' 4' 8' 14" = 1'-0" 4 EXISTING WEST ELEVATION 04' 4' 8' 1 4" = 1'-0" 5 PROPOSED WEST ELEVATION 04' 4' 8' 14" = 1'-0" 4:12 PITCH 4:12 PITCH (E) WALL TO BE REMOVED (E) ROOF TO BE REMOVED (E) WALL TO BE REMOVED (N) WALL W/ STUCCO. DUNN EDWARDS, COLOR: WARM WHITE DEW380 RL#005, TO BE MATCHED W/ (E) MAIN DWELLING WALL. (OR APPROVED EQUAL) (N) WALL W/ STUCCO. DUNN EDWARDS, COLOR: WARM WHITE DEW380 RL#005, TO BE MATCHED W/ (E) MAIN DWELLING WALL. (OR APPROVED EQUAL) (N) GARAGE DOOR RE: DOOR SCHEDULE(E) GARAGE DOOR TO BE REMOVED 7 EXISTING EAST ELEVATION 04' 4' 8' 1 4" = 1'-0" 8 PROPOSED EAST ELEVATION 04' 4' 8' 14" = 1'-0" (E) WALL TO BE REMOVED (N) WALL W/ STUCCO. DUNN EDWARDS, COLOR: WARM WHITE DEW380 RL#005, TO BE MATCHED W/ (E) MAIN DWELLING WALL. (OR APPROVED EQUAL) 3 EXISTING NORTH ELEVATION 04' 4'8' 1 4" = 1'-0" (E) WALL TO BE REMOVED 6 PROPOSED NORTH ELEVATION 04' 4' 8' 14" = 1'-0" (N) WALL W/ STUCCO. DUNN EDWARDS, COLOR: WARM WHITE DEW380 RL#005, TO BE MATCHED W/ (E) MAIN DWELLING WALL. (OR APPROVED EQUAL) (N) ROOF W/ ASPHALT SHINGLE, LANDMARK, CLASS A, COLOR TO BE MATCHED W/ (E) MAIN DWELLING ROOF, ICC-ES-ESR-1389 & ESR-3537. (OR APPROVED EQUAL) (N) ROOF W/ ASPHALT SHINGLE, LANDMARK, CLASS A, COLOR TO BE MATCHED W/ (E) MAIN DWELLING ROOF, ICC-ES-ESR-1389 & ESR-3537. (OR APPROVED EQUAL) (N) ROOF W/ ASPHALT SHINGLE, LANDMARK, CLASS A, COLOR TO BE MATCHED W/ (E) MAIN DWELLING ROOF, ICC-ES-ESR-1389 & ESR-3537. (OR APPROVED EQUAL) (E) ROOF TO BE REMOVED (E) ROOF TO BE REMOVED (E) ROOF TO BE REMOVED (E) TRIM TO BE REMOVED 4:12 PITCH 4:12 PITCH 4:12 PITCH 4:12 PITCH 4:12 PITCH 4:12 PITCH (N) RAIN GUTTER AND DOWNSPOUT.TYP. SEE SHEET D-1 (N) RAIN GUTTER AND DOWNSPOUT.TYP. SEE SHEET D-1 (N) RAIN GUTTER AND DOWNSPOUT.TYP. SEE SHEET D-1 (N) GABEL VENT 24"X18".SEE ROOF VENT CALCS. (N) ROOF W/ ASPHALT SHINGLE, LANDMARK, CLASS A, COLOR TO BE MATCHED W/ (E) MAIN DWELLING ROOF, ICC-ES-ESR-1389 & ESR-3537. (OR APPROVED EQUAL) (N) RAIN GUTTER AND DOWNSPOUT.TYP. SEE SHEET D-1 x VENTILATION CALCULATION: 1/150TH OF AREA REQUIRED AT FLOOR x AREA: 401SF 401 / 150 = 2.7 SF REQUIRED FOUNDATION VENT 24" X16" = 3 SF ( 1 FOUNDATION VENT AREA) 2.7 / 0.88 = 3 VENT REQUIRED (N) GARAGE VENT. (N) FASCIA BOARD TO MATCH W/ HOUSE FASCIA BOARD (N) FASCIA BOARD TO MATCH W/ HOUSE FASCIA BOARD (N) FASCIA BOARD TO MATCH W/ HOUSE FASCIA BOARD (N) FASCIA BOARD TO MATCH W/ HOUSE FASCIA BOARD 9 A-2 12 A-3 7 A-3 TYPICAL EXTERIOR DOOR DETAIL JAMB CASING DOOR THRESHOLD DOOR AS SCHEDULED HEAD FLASHING BACKER ROD AND SEALANT J MOLDING WITH WEEP HOLES. HELD MIN. 3" FLANGE HELD UP 1/4" FROM HEAD FLASHING (2) LAYERS BUILDING PAPER FLASHING TAPE HEADER, REFER STRUCTURAL WHERE APPLICABLE FLASHING SHEATHING EXTERIOR WALL 9 N.T.S. CEMENT STUCCO 9 A-2           1011 W Second St 5/1/2025 (N) GARAGE (N) GARAGE A-3 GARCIA RESIDENCE SHEET PROPERTY OWNER: JUAN GARCIA (949) 627-2074 REV DATE DESCRIPTION 10/16/23A THERE SHALL BE NO CHANGES OR DEVIATION ON THESE PLANS WITHOUT THE CONSENT OF PLAN AND PERMIT INC. NOTES AND DETAILS ON THE DRAW INGS SHALL TAKE PRECEDENCE OVER GENERAL NO TES AND TYPICAL DETAILS. WHERE NO DETAILS SHOWN OR NOTED ON THE DRAWINGS, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WO RK.CONTRACTOR SHALL VERIFY ALL PLANS, EXISTI NG DIMENSIONS AND FIELD CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY TO PLAN AND PERMIT INC ANY DISCREPANCIES IN WR ITING PRIOR TO THE COMMENCEMENT OF ANY WOR K OR BE RESPONSIBLE FOR SAME. TH E S E D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F P L A N A N D P E R M I T I N C A N D S H A L L N O T B E U S E D I N C O N N E CT I O N W I T H A N Y O T H E R W O R K E X C E P T B Y A G R E E M E N T W I T H P L A N A N D P E R M I T I N C . B Y U S I N G T H E S E P L A N S , T H E U S E R A G R E E S T O R E L E A S E P L A N A ND P E R M I T I N C F R O M A N Y A N D A L L C L A I M S , L I A B I L I T I E S , S U I T S , A N D D E M A N D S O N A C C O U N T O F A N Y I N J U R Y , D A M A G E O R L O S S O R P E R S O N S O R P RO P E R T Y , I N C L U D I N G I N J U R Y O R D E A T H , O R E C O N O M I C L O S S E S , A R I S I N G O U T O F T H E U S E O F T H E S E P L A N S . SKETCH FOR REVIEW 11/17/23 B 90PD FOR APPROVALC 01/02/240 100PD FOR SUBMITTAL 10/31/23 90PD FOR REVIEW PROPERTY ADDRESS: 1011 W 2ND ST, SANTA ANA, CA 92703 PLAN AND PERMIT INC. ARCHITECTURAL DESIGN SERVICES 9891 IRVINE CENTER DR #200 IRVINE, CA 92618 (714)-715-0923 biz@planandpermit.com LOCATION QR CODE: STATE OF CAL IFORNIAEXP. DATE L I C E NS E D A R CHI T E C T C - 34643 06/30/2025 SIGNATURE PAUL SAN GEMINO 1 PROPOSED SECTION 04' 4'8' 14" = 1'-0" (N) CONCRETE SLAB ON GRADE PER STRUCTURAL 5 A-3 6 A-3 (N) 1 HR FIRE RATED WALL. SEE DETAIL 8/A-3 9 A-3 4:12 PITCH 4:12 PITCH (N) R-15 INSULATION (N) R-30 INSULATION (N) RAIN GUTTER AND DOWNSPOUT.TYP. SEE SHEET D-1 2 PROPOSED SECTION 04' 4'8' 1 4" = 1'-0" (N) ROOF JOIST RE: STRUCTURAL DWGS (N) CEILING JOIST RE: STRUCTURAL DWGS EXTERIOR SHEATHING (2) LAYERS BUILDING PAPER (WEATHER-RESISTANT TYPE 1 GRADE D STYLE 2) INSULATION PER T24 REPORT PC # 3 CORNER BEAD PLASTIC 3 N.T.S. EXTERIOR WALL. STUCCO AT OUTSIDE CORNER (1) LAYERS 5/8" GYPSUM BOARD GALVANIZED METAL LATH CEMENT STUCCO WOOD FRAMING PER STRUCTURAL 2X WALL WALL PARTITION PER WALL SCHEDULE RE: FLOOR PLAN (N) R-15 INSULATION (N) R-30 INSULATION (N) ROOF JOIST RE: STRUCTURAL DWGS (N) CEILING JOIST RE: STRUCTURAL DWGS (N) CONCRETE SLAB ON GRADE PER STRUCTURAL 5 A-3 4 N.T.S.N.T.S. EXTERIOR WALL. STUCCO CEMENT STUCCO EXTERIOR SHEATHING 2X WALL (2) LAYERS BUILDING PAPER (WEATHER-RESISTANT TYPE 1 GRADE D STYLE 2) GALVANIZED METAL LATH INSULATION PER T24 REPORT NOTE: REFER TO STRUCTURAL DWGS FOR SHEAR WALL LOCATION AND SCHEDULE. EXTERIORINTERIOR (1) LAYERS 5/8" GYPSUM BOARD 5 N.T.S. WEEP SCREED @ EXTERIOR WALL PER ASTM C 926 7 N.T.S. GARAGE DOOR THRESHOLD GARAGE DOOR SLAB ON GRADE, RE : STRUCTURAL DWGS 8 N.T.S. GYPSUM WALLBOARD, WOOD STUDS FIRE DESIGN: x EXTERIOR SIDE: 5/8ʺ PROPRIETARY TYPE X GYPSUM SHEATHING APPLIED PARALLEL OR AT RIGHT ANGLES TO 2 × 4 WOOD STUDS 16ʺ O.C. WITH 1-1/4ʺ, TYPE W SCREWS 8ʺ O.C. PRE-FURRED WIRE STUCCO NETTING APPLIED OVER GYPSUM SHEATHING WITH 1-1/4ʺ × 1ʺ STEEL STAPLES 7ʺ O.C. PORTLAND CEMENT STUCCO, 3/4ʺ, APPLIED OVER STUCCO NETTING. x INTERIOR SIDE: ONE LAYER 5/8ʺ PROPRIETARY TYPE X GYPSUM WALLBOARD APPLIED PARALLEL OR AT RIGHT ANGLES TO STUDS WITH 1-1/4ʺ TYPE W SCREWS 8ʺ O.C. (LOAD-BEARING) x PROPRIETARY GYPSUM BOARD AMERICAN GYPSUM COMPANY LLC 5/8ʺ FIREBLOC® TYPE X GYPSUM BOARD 5/8ʺ TYPE X EXTERIOR GYPSUM SHEATHING INSULATION PER T24 REPORT CEMENT STUCCO (2) LAYERS BUILDING PAPER (WEATHER-RESISTANT TYPE 1 GRADE D STYLE 2) GALVANIZED METAL LATH THICKNESS: 6-1/8″ (Fire) APPROX. WEIGHT: 11 psf (Fire) FIRE TEST: UL R14196, 4787829354, 02-01-17, UL Design V333 STC : N/A GA FILE NO. WP 8170 EXTERIOR WALL, 1 HOUR FIRE, 2 X 4, LOAD-BEARING 5/8ʺ TYPE X GYPSUM SHEATHING 9 10 N.T.S. SWING DOOR THRESHOLD AT HARDSCAPE N.T.S. EAVE DETAIL WITHOUT VENTING, ATTIC CEILING 11 N.T.S. DUCT PENETRATION. TYP. 6 N.T.S. ASPHALT SHINGLE ROOF, ATTIC CEILING, WITHOUT RIDGE VENT ROOF UNDERLAYMENT ROOF SHEATHING SEE STRUCTURAL SHEETS 24GA.RIDGE FLASHING UNDERLAYMENT W/ 12" MIN. OVERLAP ASPHALT SHINGLE, LAND MARK, ICC-ES-ESR-1389 & ESR-3537 NOTE: 1. PROVIDE EITHER 1" MINIMUM CLEARANCE BETWEEN INSULATION AND ROOF SHEATHING OR USE INSULATION BAFFLE FOR RAFTER SPACE VENTILATION 2. FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) UP TO FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12), DOUBLE UNDERLAYMENT APPLICATION IS REQUIRED IN ACCORDANCE WITH SECTION R905.1.1. CEMENT STUCCO EXTERIOR SHEATHING (2) LAYERS BUILDING PAPER (WEATHER-RESISTANT TYPE 1 GRADE D STYLE 2) GALVANIZED METAL LATH INTERIOR FINISH BLOCKING AS NECESSARY 12 N.T.S. TYPICAL WINDOW DETAIL SILL,REFER STRUCTURAL WHERE APPLICABLE GYP.BOARD WIN.WRAP "L" METAL BACKER ROD AND SEALANT CEMENT STUCCO GALVANIZED METAL LATH WINDOW AS SCHEDULED FLASHING & SEALANT SHEATHING (2) LAYERS BUILDING PAPER 9" SAF LAP O/WIN.FIN BLOCKING AS NECESSARY SEAT WINDOW IN SEALANT EXTERIOR WALL HEADER WHERE OCCURS, RE: STRUCTURAL DWGS. BACKER ROD AND SEALANT CASING BEAD (2) LAYERS BUILDING PAPER UNDER FLASHING MEMBRANE ROOF JOIST RE: STRUCTURAL SHEETS 'A': NOTE THAT WEEP SCREED IS BEHIND PAPER. CEMENT STUCCOEXTERIOR SHEATHING (2) LAYERS BUILDING PAPER (WEATHER-RESISTANT TYPE 1 GRADE D STYLE 2) GALVANIZED METAL LATH SLAB ON GRADE; RE: STRUCTURAL DWGS. FOUNDATION; RE: STRUCTURAL DWGS. EXTERIOR WALL PER SCHEDULE SILL SEALER VAPOR RETARDER RE: STRUCTURAL DWGS FLASHING TAPE 'A' CORROSION-RESISTANT WEEP SCREED (26 GAGE MINIMUM) DOOR SCHEDULE MARK SIZE (W x H)TYPE MATERIAL REMARKSFINISH 12'-0" X 7'-0"ALUMINUM/FROSTED GLASS GARAGE DOOR - WHITE NOTE: 1. ALL DOOR SIZES MUST BE VERIFIED WITH THE FRAMED ROUGH OPENING IN PLACE PRIOR TO PURCHASING. ANY DISCREPANCIES SHOULD BE NOTIFIED TO PLAN AND PERMIT INC. BEFORE PURCHASING. 2. ALL GLASS IN DOORS SHALL BE TEMPERED. TEMPERED GLASS SHALL BE PERMANENTLY IDENTIFIED AND VISIBLE WHEN THE UNIT IS GLAZED. 3. ALL GLAZING WILL BE INSTALLED WITH A CERTIFYING LABEL ATTACHED, SHOWING THE "U" VALUE. 4. REFER TO FLOOR PLANS FOR DIRECTION OF DOOR SWING. 5. DOORS SHALL MEET THE MINIMUM INFILTRATION REQUIREMENTS PER SECTION 116 E.E.S. 6. VENTILATION SHALL COMPLY WITH C.B.C. 1203.4 AND R303. 7. DOORS MAY OPEN TO THE EXTERIOR ONLY IF THE FLOOR OR LANDING IS NOT MORE THAN 1 1 2" LOWER THAN THE DOOR THRESHOLD. SECTION R311.3.1 CRC 8. GLAZED OPENINGS WITHIN EXTERIOR DOORS SHALL BE INSULATNG-GLASS UNITS WITH A MINIMUM OF ONE TEMPERED PANE, NUM 12 14 N.T.S. DOOR SCHEDULE 2'-8" X 6'-8"WHITEFIBERGLASSPREHUNG FIRE RATED - SOLID CORE WITH 1-3/8" MINIMUM THICKNESS. SELF-LATCHING, SELF-CLOSING , 20 MIN. RATED - FOR GARAGE 11 13 N.T.S. WINDOW SCHEDULE MARK SIZE (W x H) TYPE OPERATION MATERIAL U-FACTOR SHGCFINISH REMARKS SLIDER XO OR OX PER CLIENT VINYL 0.23 ±4'-0" X ±3'-0" WHITE A NEW CONSTRUCTION, JELD-WEN V-2500 SERIES OR APPROVED EQUAL, WITH FIBERGLASS MESH SCREEN WINDOW SCHEDULE NOTES: 2. ALL GLAZED OPENINGS SHALL MEET THE REQUIREMENTS OF THE CBC T24 SHEETS PROVIDED IN THE PLANS. 4. GLAZING IN SWINGING, SLIDING, AND BIFOLD DOORS 9 SQUARE FEET OR LESS SHALL BE A MINIMUM CATEGORY CLASSIFICATION OF 5. EGRESS WINDOWS HAVE A MINIMUM CLEAR OPENING AREA OF 5.7 SF WHEN ABOVE THE GRADE-FLOOR AND 5 SF ON THE GRADE-FLOOR, A MINIMUM NET HEIGHT OF 24", A MINIMUM NET WIDTH OF 20", AND A SILL HEIGHT NOT MORE THAN 44" ABOVE FINISH FLOOR. [CBC 1030] 6. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL VENTILATION AND NATURAL LIGHT BY MEANS OF VENTILATION /ARTIFICIAL LIGHT. CBC SECTIONS 1203.4 AND 1205.1 AND R303 A. THE MINIMUM NET GLAZED AREA FOR NATURAL LIGHT SHALL NOT BE LESS THAN 8%OF THE FLOOR AREA OF THE ROOM SERVED. CBC SECTION 1205.2 B. THE MINIMUM OPENABLE AREA TO THE OUTDOORS FOR NATURAL VENTILATION SHALL BE 4% OF THE FLOOR AREA BEING VENTILATED. SECTION 1203.4 0.30 NUM 1 SECTIONS, DETAILS & DOOR/WINDOW SCHEDULE (N) WINDOW.SEE WINDOW SCHEDULE (N) DOOR.SEE DOOR SCHEDULE %2 SLOPE MATERIAL PER ROOF PLAN GWB ROOF UNDERLAYMENT ROOF SHEATHING INSULATION PER T24 FIRE BLOCKING WITHOUT VENT HOLES GUTTER FASCIA AIR SEAL ROOF JOIST; RE: STRUCTURAL SHEETS CEILING JOIST; RE: STRUCTURAL SHEETS WALL PARTITION PER WALL SCHEDULE RE: FLOOR PLAN CONC.FOUNDATION RE: STRUCTURAL SHEETS VAPOR RETARDER RE: STRUCTURAL DWGS CONCRETE PAD; RE: STRUCTURAL SHEETS %2 SLOPE           1011 W Second St 5/1/2025 A.F.F.ABOVE FINISHED FLOOR E.D.EDGE DISTANCE OPNG.OPENING A.F.G.ABOVE FINISHED GRADE EMBED.EMBEDMENT P.L.PROPERTY LINE (OR PARTS LIST) ARCH.ARCHITECTURAL E.N.EDGE NAILING PSF POUNDS PER SQUARE FOOT ABV.ABOVE EQ.EQUAL PSI POUNDS PER SQUARE INCH AEOR ARCHITECTURAL ENGINEER OF RECORD EXC.EXCAVATE P.T.PRESSURE TREATED BAL.BALANCE EXT.EXTERIOR R RADIUS BOT BOTTOM F.F.L.FINISHED FLOOR LEVEL RC REINFORCED CONCRETE B.N.BOUNDRY NAILING FIN.FINISH REBAR REINFORCING BAR B.O.F.BOTTOM OF FOOTING F.L .FLOOR LEVEL REINF.REINFORCEMENT B.O.W.BOTTOM OF WALL FRPF.FIREPROOF REQD.REQUIRED BLK'G BLOCKING FT.FEET SEOR STRUCTURAL ENGINEER OF RECORD B.L.L.BOTTOM LOWER LAYER G.C.GENERAL CONTRACTOR SOG SLAB ON GROUND BRG.BEARING GALV.GALVANIZED SPECS.SPECIFICATIONS BTWN.BETWEEN GYP.GYPSUM SQ. FT.SQUARE FEET B.U.L.BOTTOM UPPER LAYER H.V.A.C.HEATING, VENTILATION, AND AIR CONDITIONING SQ. IN.SQUARE INCHES B.W.L.BRACED WALL LINE HOR.HORIZONTAL SS STAINLESS STEEL CA COLUMN ABOVE H.R.S.HOT ROLLED STEEL STD.STANDARD C.C.CENTER TO CENTER I.D.INNER DIAMETER STR.STRUCTURAL C.L.CENTER LINE IN.INCH TOP&BOT TOP AND BOTTOM CLG.CEILING INSUL.INSULATION T.O.TOP OF CLR.CLEARANCE INT.INTERIOR T.O.B.TOP OF BEAM CMU CONCRETE MASONRY UNIT LVL LAMINATED VENEER LUMBER T.O.C.TOP OF CURB OR TOP OF CONCRETE CONC.CONCRETE L.FT.LINEAR FEET T.O.F.TOP OF FOOTING CONNE.CONNECTION L.L.LIVE LOAD T.O.J.TOP OF JOIST CONT.CONTINUOUS LSL LAMINATED STRAND LUMBER T.O.M.TOP OF MASONRY DEG.DEGREE MANUF.MANUFACTURER T.O.W.TOP OF WALL DIA.DIAMETER MAS.MASONRY THICK.THICKNESS DIM.DIMENSION MATL.MATERIAL TLL.TOP LOWER LAYER D.F.DOUGLAS FIR MAX.MAXIMUM TYP.TYPE DOUG. FIR DOUGLAS FIR MM MILIMETER UNO UNLESS NOTIFIED OTHERWISE D.P.DAMP-PROOFING MIN.MINIMUM V.B.VAPOR BARRIER DRP DROP N NEW VER.VERTICAL DWG.DRAWING NOM.NOMINAL V.I.F.VERIFIED IN FIELD DWGS.DRAWINGS NON-BRG.NON BEARING W/WITH E EXISTING NOT REQ.NOT REQUIRED W/O WITHOUT E.N.EDGE NAILING NTS.NOT TO SCALE WL WATER LEVEL E.W.EACH WAY O.C.ON CENTER WT.WEIGHT EA.EACH O.D.OUTSIDE DIAMETER COVER SHEET CS.01 CONSTRUCTION NOTES S0.01 CONSTRUCTION NOTES S0.02 TYPICAL S.O.G AND FOUNDATION DETAILS S1.01 TYPICAL WOOD DETAILS S1.21 TYPICAL WALL DETAILS S1.22 TYPICAL WOOD DETAILS S1.23 TYPICAL WOOD DETAILS S1.24 CEILING, ROOF & FOUNDATION PLAN S2.03 PROJECT CLIENT 0'2'4'8'16' SHEET TITLE 1011 W 2ND ST, SANTA ANA, CA 92703 JUAN GARSIA SAZAN INC. 2610 Vista Del Oro, Newport Beach, CA 92660 1011 W 2ND ST, SANTA ANA, CA 92703 INDEX OF DRAWINGS STATE LOCALTION MAP VICINITY LOCATION MAP CS.01 COVER SHEET ABBREVIATION PROJECT INFORMATION CLIENT/TENANT: JUAN GARSIA STRUCTURAL ENGINEER: MOHAMMAD JALALPOUR SAZAN INC. 2610 VISTA DEL ORO, NEWPORT BEACH, CA 92660 CELL OFFICE: 949-822-1913 CELL PHONE: 4439422153 EMAIL: MJALALPOUR@SAZANINC.COM PROJECT DESCRIPTION: 1. SAZAN'S SCOPE OF WORK IS LIMITED TO PROVIDING STRUCTURAL DESIGN, DRAWINGS AND DETAILS FOR THE DEMOLISHING AND REBUILDING THE EXISTING GARAGE (±401 SF) LIKE FOR LIKE AND REMOVING THE EXSITING SHED, LOCATED AT 1011 W 2ND ST, SANTA ANA, CA 92703. 2. SAZAN PERFORMED THE DESIGN CONSIDERING THE AVAILABLE INFORMATION FOR THE STRUCTURE. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE THAT SAZAN WAS NOT AWARE OF, OR WHICH WAS UNKNOWN AT THE TIME OF ANALYSIS OR DESIGN, SAZAN RESERVES THE RIGHT TO REVISE THE DESIGN AS NEEDED AND ADDITIONAL COSTS MAY BE REQUIRED. 3. SAZAN PERFORMED THE STRUCTURAL DESIGN IN A MANNER CONSISTENT WITH THE LEVEL OF SKILL AND CARE ORDINARILY EXERCISED BY PROFESSIONAL ENGINEERS AND CONSULTANTS PRACTICING UNDER SIMILAR CONDITIONS. NO OTHER REPRESENTATION, WARRANTY, OR GUARANTEE IS GIVEN. PROVIDED OPINIONS ARE BASED ON OUR ENGINEERING JUDGMENT. SAZAN WILLa NOT BE RESPONSIBLE FOR LATENT DEFECTS THAT MAY APPEAR IN THE FUTURE OR FOR DIFFERENT OPINIONS OF OTHERS THAT MAY ARISE. 4. THE DESIGN AND DETAIL OF GUARDRAILS, HANDRAILS AND CHIMNEY ARE NOT INCLUDED IN THIS SCOPE OF WORK. 5. STRUCTURAL OBSERVATION AND SPECIAL INSPECTIONS ARE NOT INCLUDED IN THIS SCOPE OF WORK. 6. ALL WORK SHALL COMPLY WITH THE 2022 EDITION OF CBC, CRC, CMC, CPC, CEC, CGBSC, CEES, AND ALL AMENDMENTS OF THE CITY OF SANTA ANA AND LOCAL AUTHORITIES INCLUDING LOCAL ORDINANCE. 7. WATERPROOFING AND WATER DRAINAGE ARE NOT PART OF THIS SCOPE OF WORK. 8. OWNER IS SOLELY RESPONSIBLE FOR THE ACCURACY OF THE PROVIDED INFORMATION AND SAZAN TAKES NO LIABILITY FOR THE ACCURACY OF THE PROVIDED INFORMATION. 1 1 1 11/19/2024 EXP. 06-30-2026 1011 W Second St 5/1/2025 1. REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE TO AMERICAN CONCRETE INSTITUTE ACI 301 “SPECIFICATIONS FOR STRUCTURAL CONCRETE” AND CONCRETE REINFORCING STEEL INSTITUTE (CRSI) “MANUAL OF STANDARD PRACTICE.” 2. REINFORCING STEEL FOR FOUNDATIONS, SLABS ON GRADE, AND ELEVATED SLABS SHALL CONFORM TO ASTM A615/A615M, GRADE 60, UNLESS NOTED OTHERWISE. BARS TO BE WELDED SHALL CONFORM TO LOW ALLOY ASTM A706/A706M, GRADE 60. 3. WELDED WIRE REINFORCEMENT (WWR) SHALL CONFORM TO ASTM A1064/A1064M. SPLICE LENGTH FOR WELDED WIRE REINFORCEMENT SHALL BE AT LEAST 8 INCHES, MEASURED BETWEEN OUTERMOST CROSS WIRE OF EACH REINFORCEMENT SHEET. 4. ALL REINFORCING STEEL SHALL BE SPLICED AS SPECIFIED ON THESE DRAWINGS. IF NO LOCATION IS SPECIFIED, LOCATE SPLICES IN AREAS OF MINIMUM STRESS. SPLICE LENGTHS SHALL NOT BE LESS THAN THE LENGTHS INDICATED ON THESE DRAWINGS. 5. MINIMUM CONCRETE COVER AND CLEARANCES BETWEEN REINFORCING STEEL BARS SHALL BE SATISFIED AT ALL LOCATIONS INCLUDING SPLICES. THE CLEARANCE BETWEEN THE REINFORCING STEEL BARS SHALL NOT BE LESS THAT THE GREATER VALUE OF ONE BAR DIAMETER, ONE INCH, AND 4/3 TIMES THE MAXIMUM SIZE OF THE AGGREGATE. AT COLUMNS AND BEAM, PROVIDE 1 1/2 INCHES OR 1.5 TIMES THE LARGEST LONGITUDINAL BAR DIAMETER, WHICHEVER IS GREATER. FOR CONSIDERING THE COVER AND CLEAR DISTANCE IN BUNDLED BARS, TOTAL AREA OF BUNDLE SHALL BE CONSIDERED FOR CALCULATING EQUIVALENT BAR DIAMETER. 6. CONCRETE COVERAGE FOR REINFORCING STEEL PLACED IN CAST-IN-PLACE CONCRETE SHALL BE AS TABLE CONCOV-1. 7. IF SPACERS AND CHAIRS ARE RESTING ON EXPOSED CONCRETE SURFACES, THEY SHALL BE PASTIC COATED OR USE PLASTIC. 8. ELECTRODES UTILIZED IN WELDING OF REINFORCING STEEL, SHALL BE LOW HYDROGEN ELECTRODE AS SPECIFIED IN AMERICAN WELD SOCIETY AWS D1.4 “STRUCTURAL WELDING CODE - REINFORCING STEEL.” 9. ALL REINFORCING STEEL SHALL BE BENT COLD AND PRIOR TO PLACING THE BARS. RE-BENDING OF PREVIOUSLY BENT REINFORCING STEEL IS NOT PERMITTED. BENDING OF REINFORCEMENT IN PREVIOUSLY CAST CONCRETE IS NOT PERMITTED. OFFSET BARS SHALL BE BENT PRIOR TO PLACEMENT IN THE FORMS. HOOKING AND WALKING-IN ARE NOT PERMITTED. 10. FIRMLY SECURE ALL REINFORCING STEEL BARS AND WELDED WIRE REINFORCING WHILE PLACING CONCRETE. WHERE REQUIRED, ADDITIONAL CHAIRS, CONCRETE BLOCKS, STEEL BARS, BOLSTERS, OR OTHER APPROVED MEANS AND METHODS SHALL BE PROVIDED BY THE CONTRACTOR TO FURNISH ALL REQUIRED SUPPORTS FOR ALL REINFORCING. 11. PRIOR TO FINAL INSPECTION, CLEARLY MARK ALL REINFORCING STEEL SO THEIR IDENTIFICATION CAN BE PROPERLY MADE AT THE TIME OF INSPECTION. REINFORCING STEEL 1. ALL WOOD OR WOOD BASED MATERIALS SHALL CONFORM TO THE FOLLOWING STANDARDS: 1.1. ALL STRUCTURAL WOOD LUMBERS AND TIMBERS SHALL BE DOUGLAS FIR-LARCH CONFORMING TO THE REQUIREMENTS OF WWPA OR WCLIB UNLESSE NOTE OTHERWISE ON THESE DRAWINGS. 1.2. STRUCTURAL ALL STRUCTURAL PLYWOOD SHALL BE DOUGLAS FIR LARCH AND SHALL CONFORM TO THE REQUIREMENTS OF USDOC PS 1—09 OR MORE RECENT EDITION. 1.3. ALL STRUCTURAL PANELS SHALL CONFORM TO THE REQUIREMENTS OF USDOC PS 2—10 OR MORE RECENT EDITION. 1.4. ALL STRUCTURAL SAWN LUMBER INCLUDING END-JOINTED OR EDGE-GLUED LUMBER, MACHINE STRESS-RATED OR MACHINE-EVALUATED LUMBER, SHALL BE IDENTIFIED BY THE GRADE MARK OF A LUMBER GRADING OR INSPECTION AGENCY THAT HAS BEEN APPROVED BY AN ACCREDITATION ODY BODY THAT COMPLIES WITH DOC PS 20-05 OR MORE RECENT EDITION. 1.5. ENGINEERED WOOD RIM BOARDS SHALL CONFORM TO ANSI/APA PRR 410-2021 OR MORE RECENT EDITION. 2. UNLESS NOTED OTHERWISE, ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR-LARCH CONFORMING TO THE LATEST EDITION OF NDS FOR THE TABLE FL-1. 3. MEMBER SIZES SHOWN ARE NOMINAL UNLESS NOTED OTHERWISE. 4. ALL CONNECTORS AND FASTENERS SHALL COMPLY WITH THE APPLICABLE PROVISIONS AND TABLES OF SECTIONS 2304.10.1 THROUGH 2304.10.7 OF CBC 2022. 5. ALL WOOD AND WOOD BASED MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF AMERICAN WOOD PROTECTION ASSOCIATION (AWPA) U1 FOR THE USE CATEGORY OF THE COMPONENT. 6. ANY PRESERVATIVE-TREATED WOOD MEMBERS THAT ARE ALTERED, CUT, DRILLED OR NOTCHED ON THE FIELD, SHALL BE RETREADED AS SPECIFIED BY MANUFACTURER AND APPROVED BY LOCAL AUTHORITIES. IF NO WRITTEN RECOMMENDATIONS ARE PROVIDED, ALL DRILLED HOLES AND CUT ENDS NEED TO BE TREATED WITH A PRESERVATIVE, TO CONFORM AMERICAN WOOD PROTECTION ASSOCIATION (AWPA) STANDARD M4. 7. FASTENERS SHALL CONFORM TO THE REQUIREMENTS SPECIFIED ON THESE DRAWINGS. FASTENERS SHALL NOT BE PLACED CLOSER THAN THE SPECIFIED EDGE AND END DISTANCES. SPACING OF THE FASTENERS SHALL BE AS SPECIFIED. 8. FASTENERS HEAD SHALL BE DRIVEN FLUSH WITH THE SURFACES AND SHALL NOT FRACTURE OR DAMAGE THE LUMBER OR SHEATHING SURFACES. 9. PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIA. AND FULL DIA. FOR SMOOTH SHANK PORTION OF LAG BOLTS. THREADED CONNECTORS SUCH AS LAG SCREWS AND WOOD SCREWS SHALL BE INSTALLED BY TURNING WIDTH A WRENCH. HAMMER DRIVEN SCREWS SHALL NOT BE PERMITTED. 10. ALL BOLT HOLES, OTHER THAN LAG BOLT HOLES, SHALL BE DRILLED A MINIMUM OF 1/32" TO A MAXIMUM OF 1/16" LARGER THAN BOLT DIAMETER. HOLES SHALL BE ACCURATELY ALIGNED IN THE MAIN MEMBERS AND SIDE PLATES. BOLTS SHALL NOT BE FORCIBLY DRIVEN. INSPECTOR SHALL VERIFY ALL HOLES AT JOB SITE 11. PROVIDE LATERAL SUPPORT FOR THE TOP OF INTERIOR NON-BEARING WALLS WHEN MANUFACTURED TRUSSES ARE USED. 12. ALL ROOF/FLOOR AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. GALVANIZED NAILS SHALL BE HOT-DIPPED OR TUMBLED. NAIL GUNS USING "CLIPPED HEAD" OR SINKER NAILS ARE NOT ACCEPTABLE. 13. ROOF/FLOOR NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. 14. STUCCO SHEAR WALLS SHALL UTILIZE FURRING, GALVANIZED NAILS (HAVING A MINIMUM 11 GA., 1-1/2" LONG, 7/16" DIAMETER HEAD, AND FURRED OUT A MIN OF 1/4") TO ATTACH THE LATH TO THE STUDS. (TABLE 2306.3(3)). 15. SHOP WELDS SHALL BE PERFORMED WITH LICENSED FABRICATORS. 16. STRUCTURAL WOOD SHEAR WALLS SHALL BE COVERED WITH MINIMUM TWO LAYERS GRADE D FELT UNDERLAY PRIOR TO PLACING FINISH MATERIAL. 17. HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE WASHERS. HOLD-DOWNS SHALL BE FINGER TIGHT AND 1/2 WRENCH TURN JUST PRIOR TO COVERING THE WALL FRAMING. CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE STEEL PLATE WASHERS ON THE POST ON THE OPPOSITE SIDE OF THE ANCHORAGE DEVICE. PLATE SIZE SHALL BE A MINIMUM OF 0.25 IN. BY 3 IN. BY 3 IN. 18. MAXIMUM MOISTURE CONTENT FOR FRAMING LUMBER INCLUDING PRESERVATIVE-TREATED WOOD SHALL NOT EXCEED 19% AT THE TIME OF PLYWOOD OR GYPBOARD COVERAGE INSTALLATION. 19. UNLESS NOTED OTHERWISE, FRAMING LUMBER USED FOR COMPLETELY NEW CONSTRUCTIONS SHELL BE STAMPED AS KILN-DRIED (KD), HEAT TREATED (KD-HT), SURFACE-DRY (S-DRY) LUMBER OR MC-15 LUMBER. (S-DRY) LUMBER SHALL NOT BE PERMITTED TO BE USED IN EXISTING CONSTRUCTION OR FOR THE NEW CONSTRUCTIONS THAT ARE ATTACHED TO EXISTING CONSTRUCTION. 20. TOP AND BOTTOM PLATES OF WALLS SHALL BE KLIN DRIED FOR BUILDINGS MORE THAN TWO STORIES. 21.PROVIDE DOUBLE JOISTS OR 4x BEAM GIRDERS UNDER PARALLEL PARTITIONS. STITCH NAIL THE DOUBLE SWAN JOISTS WITH 16D NAILS SPACED NOT MORE THAN THE LESSER OF JOISTS DEPTH AND 12 IN. NAILS SHALL BE STAGGERED AT THE TOP AND BOTTOM. 22.PROVIDE DOUBLE 2X OR 4X BLOCKING UNDER WALLS OR PARTITIONS PERPENDICULAR TO THE JOISTS. 23.UNO, ALL DISCONTINUOUS WALLS SHALL BE SUPPORTED ON BEAMS, DOUBLE JOISTS OR SOLID BLOCKING WITH THE WIDTH NOT LESS THAN THE WIDTH OF THE SUPPORTED WALL. 24. ALL WOOD BOLTS AND LAG SCREWS SHALL CONFORM TO REQUIREMENTS OF ANSI/ASME B18.2.1, WOOD SCREWS SHALL CONFORM TO THE REQUIREMENTS OF ANSI/ASME B18.6.1, AND NAILS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F1667. 25. ALL NAILS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F1667. UNLESS OTHERWISE NOTED ON THESE DRAWINGS, ALL NAILS SHALL BE COMMON WIRE NAILS, AND NUMBER OF CONNECTING NAILS AT EACH LOCATION SHALL NOT BE LESS THAN THE SPECIFIED NUMBERS ON THESE DRAWINGS. ALL NAILS THAT ARE EXPOSED TO WEATHER OR MOISTURE SHALL BE HOT-DIPPED GALVANIZED COMMON NAILS THAT CONFORMS TO ASTM A153 CLASS D. NAILS SHALL CONFORM TO THE REQUIREMENTS SPECIFIED IN TABLE FL-2. NAILS. 26. ALL HORIZONTAL JOINTS OCCURRING IN BRACED / SHEAR WALL PANELS SHALL OCCUR OVER BLOCKING EQUAL IN SIZE TO THE STUDDING. 27. ALL STEEL BOLT AND RODS SHALL CONFORM TO ASTM A307 OR ASTM F1554 GR. 36. ALL BOLT HOLES SIZES SHALL INSPECTED AND VERIFIED AT JOB SITE. 28. ALL BOLTS, NUTS, AND LAG SCREWS THAT BEAR ON WOOD MATERIALS SHALL HAVE STANDARD CUT WASHERS UNDER THE BOLT HEAD AND NUTS. NOT MORE THAN 24 HRS PRIOR TO COVERING THE BOLTS, ALL BOLTS SHALL BE RETIGHTENED. 29. PROVIDE FULL HEIGHT SOLID BLOCKING AT THE ENDS OF THE SWAN LUMBERS JOISTS, BEAMS AND RAFTERS ABOVE AND BELOW WALLS. INTERMEDIATE FULL BLOCKING OF THE SWAN LUMBERS SHALL NOT BE SPACED MORE THAN 8 FT O.C. 30. PROVIDE ONE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG THE JOISTS WITH SPANS GREATER THAN 8 FT BUT LESS THAN 16 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED MID-SPAN OF THE JOIST. 31. PROVIDE TWO INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG THE JOISTS WITH SPANS GREATER THAN 16 FT BUT LESS THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED 1/3 OF THE SPAN FROM EACH END. 32. PROVIDE THREE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG THE JOISTS WITH SPANS GREATER THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED NOT MORE THAN 8 FT ALONG THE SPAN FROM EACH OTHER. 33. APPROVED METAL BRIDGING THAT HAVE CURRENT ICC ES EVALUATION MAY BE USED INSTEAD OF SOLID BLOCKING FOR FULL HEIGHT INTERMEDIATE SUPPORTS. 34. DO NOT SUSPEND CEILINGS, SOFFITS, SPRINKLERS, PIPING, MECHANICAL DUCTS, NOR ANY OTHER ELEMENT FROM 2X4 ROOF FRAMING UNLESS SPECIFICALLY DETAILED. 35. CUTTING, NOTCHING, AND BORING OF WOOD FRAMING MEMBERS SHALL BE IN ACCORDANCE WITH CBC SECTION 2308.5.9. AND AS SHOWN ON THESE DRAWINGS. 36. FIRE-RETARDANT-TREATED WOOD IS ANY WOOD PRODUCT THAT, WHEN IMPREGNATED WITH CHEMICALS BY A PRESSURE PROCESS OR OTHER MEANS DURING MANUFACTURE, SHALL HAVE, WHEN TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723, A LISTED FLAME SPREAD INDEX OF 25 OR LESS AND SHOW NO EVIDENCE OF SIGNIFICANT PROGRESSIVE COMBUSTION WHEN THE TEST IS CONTINUED FOR AN ADDITIONAL 20-MINUTE PERIOD. ADDITIONALLY, THE FLAME FRONT SHALL NOT PROGRESS MORE THAN 10-1/2 FEET BEYOND THE CENTERLINE OF THE BURNERS AT ANY TIME DURING THE TEST. 37. SQUASH BLOCKS WITH THE SAME WIDTH SHALL BE PROVIDED UNDER ALL BEARING POINT LOADS FROM ABOVE TO THE TOP OF THE TOP PLATES BELOW AT FLOOR LEVELS. 38. LATERAL BRACING OF WEB MEMBERS IN TRUSSES SHALL BE END ON AN EXTERIOR SHEAR/BRACING WALL. 39. BLOCKING REQUIRED FOR LIGHT FEATURES, CABINETS, HANDRAILS, GUARDRAILS TOWEL BARS OR OTHER LIGHT ATTACHMENTS ARE NOT SHOWN ON THESE DRAWINGS AND SHALL BE PROVIDED BY GC AS REQUIRED BASED ON ARCHITECTURAL, AND MEP DRAWINGS. 40. FIREBLOCKS NOT SMALLER THAN 2 IN. NOMINAL SHALL BE PROVIDED TO CUT OFF ALL HORIZONTAL AND VERTICAL DRAFTS BETWEEN TWO STORIES AND ROOF ATTIC SPACES. FIREBLOCKS SHALL BE PROVIDED AT STUD WALLS AT FURRED SOFFITS, CEILING AND FLOOR LEVELS, . BETWEEN STAIR STRINGERS AT TOP AND BOTTOM OF RUN AND BETWEEN STUDS IN A WALL PARALLEL AND ADJOINING RUN OF STAIRS, AROUND TOP, BOTTOM, SIDES AND ENDS OF SLIDING POCKET DOOR. 41. FURRING SHALL BE PROVIDED TO ALIGN SHEAR WALLS WITH ALL OTHER WALLS. 42. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLK'G SHALL BE PROVIDED AT PLYWD JOINTS FOR ALL WALLS. 43. ALL STEEL CONNECTORS INCLUDING BOLTS, SCREWS AND NAILS USED IN EXTERIOR STRUCTURE OR EXPOSED TO WEATHER SHALL BE STAINLESS STEEL OR HOT-DIP GALVANIZED. FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT TREATED WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. ENGINEERED WOOD PRODUCTS 1. ALL STRUCTURAL GLUED-LAMINATED TIMBERS AND STRUCTURAL COMPOSITE LUMBERS AND ORIENTED STRAND BOARDS SHALL HAVE A CURRENT ICC ES EVALUATION REPORT AND AS A MINIMUM SHALL CONFORM TO REQUIREMENTS SPECIFIED IN TABLE FL-3 : 2. GLUED-LAMINATED TIMBERS SHALL BE MANUFACTURED AND IDENTIFIED AS REQUIRED IN AMERICAN INSTITUTE OF TIMBER CONSTRUCTION, ANSI/AITC A 190.1 AND AMERICAN SOCIETY FOR TESTING AND MATERIALS ASTM D3737. 3. STRUCTURAL GLUED LAMINATED TIMBER SHALL BE MADE OF 1-1/2 IN. DOUGLAS FIR LAMINATION WITH 24-F COMBINATION AS SPECIFIED IN AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC). 4. UNLESS NOTED OTHERWISE, ALL GLUED LAMINATED TIMBERS SHALL BE GRADE INDUSTRIAL BAR SIZE NO. YIELD STRENGTH OF STEEL 60,000 PSI (420 MPA) SPLICE LENGTH OR TENSION DEVELOPMENT LENGTH (IN.) LAP SPLICE LENGTH-TENSION 4 30 5 38 6 45 TENSION DEVELOPMENT LENGTH FOR STRAIGHT BAR 4 23 5 28 6 34 TENSION DEVELOPMENT LENGTH FOR: A. 90° AND 180° STANDARD HOOKS WITH NOT LESS THAN 2 1/2" OF SIDE COVER PERPENDICULAR TO PLANE OF HOOK. B. 90° STANDARD HOOKS WITH NOT LESS THAN 2" OF COVER ON THE BAR EXTENSION BEYOND THE HOOK. 4 9 5 11 6 13 TENSION DEVELOPMENT LENGTH FOR BAR WITH 90° OR 180° STANDARD HOOK HAVING LESS COVER THAN REQUIRED IN ITEMS A AND B. 4 12 5 15 6 18 TABLE CAST-1. CONCRETE MINIMUM MECHANICAL PROPERTIES LOCATION COMPRESSIVE STRENGTH (PSI)TYPE FOOTING 4,500 NORMAL WEIGHT (145 PCF) SLAB-ON-GROUND 4,500 NORMAL WEIGHT (145 PCF) ALL OTHER STRUCTURAL ELEMENTS 4,500 NORMAL WEIGHT (145 PCF) TABLE FUND-1. SOIL PROPERTIES PARAMETER VALUE UNIT ALLOWABLE BEARING CAPACITY (D+L)1,500 PSF FRICTION COEFFICIENT N/A PASSIVE SOIL RESISTANCE N/A PCF AT REST SOIL PRESSURE N/A PCF ACTIVE SOIL PRESSURE N/A PCF INCREMENTAL SEISMIC PRESSURE N/A PCF 1. ALL CONCRETE WORK SHALL CONFORM TO THE STANDARDS OF THE AMERICAN CONCRETE INSTITUTE, ACI 301 “SPECIFICATION FOR STRUCTURAL CONCRETE” AND ALL APPLICABLE MODIFICATIONS AS NOTED IN THE CONTRACT DOCUMENTS OR BY LOCAL AUTHORITIES. 2. CONCRETE SHALL ATTAIN THE FOLLOWING MINIMUM MECHANICAL PROPERTIES AT 28-DAY, UNLESS NOTED OTHERWISE IN TABLE CAST-1. 3. UNLESS NOTED OTHERWISE IN GEOTECHNICAL REPORT OR CONTRACT DOCUMENTS, CONCRETE MIX SHALL CONFORM TO THE REQUIREMENTS FOR CONCRETE ASSIGNED TO EXPOSURE CLASSES F1, S2, W0, AND C1, AS DEFINED IN TABLE 19.3.1.1 OF ACI 318. 4. UNLESS NOTED OTHERWISE IN GEOTECHNICAL REPORT OR CONTRACT DOCUMENTS, PORTLAND CEMENT FOR CONCRETE SHALL CONFORM TO ASTM C150 TYPE V. 5. UNLESS NOTED OTHERWISE IN CONTRACT DOCUMENTS, WATER CEMENT RATIO (W/cm) SHALL BE BASED ON THE REQUIREMENTS FOR SPECIFIED EXPOSURES, AND IT SHALL NOT EXCEED 0.45. 6. DETERIORATED OR CONTAMINATED MATERIALS SHALL NOT BE USED IN CONCRETE PRODUCTION. CONCRETE PRODUCTION INCLUDING EQUIPMENT USED TO MIX; BATCH AND DELIVERY SHALL CONFORM TO ASTM C94 OR ASTM C685. 7. CONCRETE SHALL BE MOIST CURED FOR AT LEAST 7 DAYS OF PLACEMENT EXCEPT IF APPROVED ACCELERATED CURING COMPOUND OR HIGH-SOLIDS CURING COMPOUND IS USED. 8. THE CONCRETE MAINTAINED AT A TEMPERATURE OF AT LEAST 50°F DURING THE CURING TIME BUT NOT LESS THAN 7 DAYS. 9. UNLESS APPROVED BY ARCHITECT, NO CURING COMPOUNDS, SEALERS, HARDENERS, ETC., SHALL BE ADDED TO OR APPLIED ON CONCRETE RECEIVING FINISHES. 10. AGGREGATE SHALL CONFORM TO ASTM C33 FOR NORMALWEIGHT CONCRETE. NORMALWEIGHT CONCRETE SHALL HAVE A MINIMUM DRY UNIT WEIGHT OF 145 PCF. 11. MAXIMUM AGGREGATE SIZE FOR FOUNDATION CONCRETE SHALL BE 1-1/2 IN. MAXIMUM AGGREGATE SIZE FOR OTHER MEMBERS SHALL BE 1 IN. BUT NOT LARGER THAN THE LEAST OF, ¾ THE MINIMUM CLEAR SPACING BETWEEN REINFORCING STEEL BARS INCLUDING SPLICES AND 1/5 THE NARROWEST DIMENSIONS BETWEEN SIDE OF THE FORMS. 12. FRESH CONCRETE SLUMP IN FLATWORK SHALL NOT BE MORE THAN 4 INCHES. 13. CONCRETE MIX SHALL BE BASED ON THE REQUIREMENTS STATED IN SECTION 4.2.3 OF ACI 301 FOR TRIAL MIXTURE OR/AND FIELD EXPERIENCES. 14. UNLESS NOTED OTHERWISE, ALL PREVIOUSLY HARDENED CONCRETE AT CONSTRUCTION JOINT SHALL BE CLEAN, FREE OF LAITANCE, AND INTENTIONALLY ROUGHENED TO FULL AMPLITUDE OF ¼ IN. PRIOR TO FRESH CONCRETE PLACEMENT. 15. UNLESS APPROVED BY THE STRUCTURAL ENGINEER, CENTER TO CENTER SPACING OF THE PIPES AND CONDUITS SHALL NOT BE LESS THAN 3 TIMES THE LARGEST DIAMETER OF PIPES OR CONDUITS, AND CLEAR SPACING BETWEEN THE EMBEDMENTS SHALL NOT BE LESS THAN 4 IN. 16. EMBEDMENTS PARALLEL TO THE CONSTRUCTION JOINTS SHALL NOT BE PLACED CLOSER THAN DEVELOPMENT LENGTH OF THE LARGER BAR CROSSING THE CONSTRUCTION JOINT. CROSSING OF THE CONDUITS SHALL NOT BE PERMITTED. 17. PIPES AND CONDUITS SHALL BE PLACED IN THE MIDDLE THIRD OF THE SLAB, FOUNDATION, AND WALL THICKNESS OR BEAM AND GIRDER SIDE DIMENSION. 18. SLEEVES SHALL BE PROVIDED FOR PLUMBING AND ELECTRICAL PENETRATIONS AND OPENINGS. ALUMINUM EMBEDMENTS SHALL BE COATED OR COVERED. NO CONTACT BETWEEN ALUMINUM AND CONCRETE OR ELECTROLYTIC ACTION BETWEEN ALUMINUM AND STEEL IS PERMITTED. 19. DO NOT DAMAGE REINFORCING STEEL. WHERE CONFLICT OCCURS BETWEEN REINFORCING STEEL AND EMBEDMENTS OR SLEEVES LAYOUT, REPOSITION THE SLEEVES OR REINFORCING STEEL. UNLESS APPROVED BY STRUCTURAL ENGINEER, CORING IS NOT PERMITTED. 20.CONCRETE SHALL BE PLACED IN ACCORDANCE WITH ACI 304. PROPERLY SECURE ALL REINFORCING STEEL, EMBEDMENT PARTS, PIPES, CONDUITS, ANCHORS, AND OTHER CONCRETE EMBEDMENTS IN POSITION, PRIOR TO PLACING CONCRETE. REMOVE DEBRIS AND CLEAN REINFORCING STEELS AND FORM PRIOR TO PLACING CONCRETE. 21.KEYED CONSTRUCTION JOIST SHALL BE PROVIDED AS SHOWN ON THESE DRAWINGS. 22.FORMWORK DESIGN, CONSTRUCTION, AND REMOVAL SHALL BE IN ACCORDANCE WITH ACI 347 AND ACI 347.2R. CONSTRUCTION LOADS MAY BE GREATER THAN THE SPECIFIED STRUCTURAL LIVE LOADS. 23.GROUT SHALL BE NON-METALLIC, NON-SHRINK AND SHALL ATTAIN A 28-DAY COMPRESSIVE STRENGTH OF AT LEAST TWICE THE STRENGTH OF THE CONCRETE BEARING ON, BUT NOT LESS THAN 7,000 PSI. GROUT SHALL NOT CONTAIN CHLORIDES. UNLESS APPROVED BY STRUCTURAL ENGINEER, GROUT THICKNESS SHALL NOT BE LESS THAN 1 IN. INFORM STRUCTURAL ENGINEER FOR WRITTEN APPROVAL WHERE GROUT WITH MORE THAN 1 1/2 IN. THICKNESS IS REQUIRED. 24. WHERE LEAN CONCRETE IS SPECIFIED ON THE DRAWINGS, LEAN CONCRETE SHALL CONTAIN A MINIMUM OF 2 SACKS OF CEMENT PER CUBIC YARD ON CONCRETE. 25. ALUMINUM OR ALUMINUM ALLOY PIPES SHALL NOT BE USED FOR PUMPING AND DELIVERING FRESH CONCRETE. 26.UNLESS NOTED OTHERWISE BY STRUCTURAL ENGINEER OR CONTRACT DOCUMENTS, AT LEAST TWO 6X12 IN. OR THREE 4X8 IN. CONCRETE SAMPLES SHALL BE MOLDED, FIELD-CURED, AND TESTED IN ACCORDANCE WITH ASTM C31 AND ASTM C39. 27.CONCRETING IN HOT WEATHER AND COLD WEATHER SHALL BE IN ACCORDANCE WITH ACI 305.1 AND ACI 306.1 AND ACI 301. ACI 301 SHALL BE CONSIDERED AS GOVERNING DOCUMENT UNLESS NOTE OTHERWISE ON THE CONTRACT SPECIFICATIONS OR DOCUMENTS. 28.IF ANCHOR BOLTS ARE PLACED IN THE TOP OF A COLUMNS PILE OR PEDESTAL, THE BOLTS SHALL BE ENCLOSED BY TRANSVERSE REINFORCEMENT THAT ALSO SURROUNDS AT LEAST FOUR LONGITUDINAL BARS WITHIN THE PILE OR PEDESTAL. THE TRANSVERSE REINFORCEMENT SHALL BE DISTRIBUTED WITHIN THE TOP 5 IN. OF THE COLUMN OR PEDESTAL AND SHALL CONSIST OF AT LEAST TWO NO. 4 OR THREE NO. 3 BARS. 29. THE TESTING AGENCY PERFORMING ACCEPTANCE TESTING SHALL COMPLY WITH ASTM C1077. CAST IN PLACE CONCRETE FOUNDATIONS 1. NO GEOTECHNICAL REPORT WAS PROVIDED. THE DESIGN OF FOUNDATION IS BASED ON THE DEFAULT VALUE PROVIDED IN FOUNDATION REQUIREMENTS FOR RESIDENTIAL PROJECTS AND ACCESSORY STRUCTURES DATED 06/22/2020 BY THE COUNTY OF ORANGE DEPARTMENT OF PUBLIC WORKS. THE DESIGN OF FOUNDATION IS ALSO BASED ON THE DEFAULT VALUES PROVIDED IN TABLE 1806.2 OF CBC 2022 FOR SOIL CLASS 5 (CL, ML, MH AND CH). SEE TABLE FUND-1 FOR THE DESIGN PARAMETERS RECOMMENDED BY THE ABOVE REFERENCED DOCUMENT AND WERE CONSIDERED FOR THE FOUNDATION DESIGN OF THIS PROJECT. A 33% INCREASE FOR BEARING CAPACITY WAS CONSIDERED FOR LOAD COMBINATIONS INCLUDING WIND OR SEISMIC LOADS. 2. EXTERIOR & INTERIOR FOUNDATIONS SHALL BE CARRIED AT LEAST 24 IN. & 18 IN. INTO FIRM UNDISTURBED NATURAL OR COMPACTED SOIL UNO ON THE PLANS OR DETAILS. 3. IF A GEOTECHNICAL ENGINEER IS HIRED BY THE OWNER, FOUNDATION, EARTHWORK, AND EXCAVATION DRAWINGS SHALL BE SUBMITTED TO THE GEOTECHNICAL ENGINEER TO REVIEW AND APPROVE FOR COMPLIANCE WITH THE GEOTECHNICAL ENGINEER'S RECOMMENDATIONS, PRIOR TO SUBMITTING THE DRAWINGS TO THE CITY FOR PERMIT APPLICATION. 4. EXCAVATION AND STABILITY OF SLOPES ARE NOT PART OF THE DESIGN SCOPE, AND CONTRACTOR SHALL REMAIN SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES INCLUDING BUT NOT LIMITED TO LAGGING, SHORING, RESHORING UNDERPINNING AND PROTECTION OF EXISTING CONSTRUCTION. 5. NO CONSTRUCTION, EXPANSION OR COLD JOINTS ARE PERMITTED IN THE FOUNDATIONS AND GRADE BEAMS, UNLESS SPECIFICALLY SHOWN ON THESE DRAWINGS. 6. STANDING WATER SHALL BE REMOVED FROM THE FOUNDATION EXCAVATIONS PRIOR TO THE CONCRETE PLACING. 7. NOTIFY THE OWNER'S REPRESENTATIVE, IF ANY BURIED CONSTRUCTIONS THAT ARE NOT INDICATED ON THESE DRAWINGS ARE FOUND ON THE CONSTRUCTION SITE. UNLESS SPECIFICALLY SHOWN ON THESE DRAWINGS, DO NOT DAMAGE ANY EXISTING BURIED STRUCTURES SUCH AS CESSPOOLS, CISTERNS, FOUNDATIONS, ETC. 8. LOCATE ALL UTILITIES PRIOR TO COMMENCING THE WORK. EXISTING EMBEDDED OR SURFACE UTILITIES SHALL BE PROTECTED TO REMAIN UNDAMAGED DURING AND AFTER CONSTRUCTION WORK. 9. UNLESS NOTED OTHERWISE, OR REQUIRED BY THE LOCAL AUTHORITIES, REMOVE ABANDONED FOUNDATIONS, UTILITIES, PIPES, ETC. WHEREVER INTERFERE WITH THE NEW CONSTRUCTION OR IMPOSE DANGERS. 10. UNLESS NOTED OTHERWISE ON CONTRACTUAL DOCUMENTS, OR REQUIRED BY THE LOCAL AUTHORITIES, EXCAVATIONS FOR FOUNDATIONS MUST BE ACCEPTED BY THE APPROVED REPRESENTATIVE OF GEOTECHNICAL ENGINEER OR INSPECTORS PRIOR TO PLACING REINFORCING AND CONCRETE. NOTIFY THE GEOTECHNICAL ENGINEER WHEN EXCAVATIONS ARE READY FOR INSPECTION. 11. WHERE EXCAVATION IS CAPABLE OF MAINTAINING A VERTICAL CUT WITHOUT SLOUGHING, FOUNDATIONS MAY BE CAST DIRECTLY AGAINST EXCAVATIONS PROVIDED. WHERE FOUNDATIONS ARE CAST AGAINST EARTH, DIMENSIONS OF THE FOUNDATIONS SHALL BE ENLARGED BY AN ADDITIONAL ONE INCH IN THE DIRECTION OF THE SIDE CAST AGAINST EARTH. 12. CONCRETE SHALL NOT BE PLACED ON FROZEN GRADE. FOUNDATIONS THAT MAY SUBJECT TO FREEZING TEMPERATURES AFTER FOUNDATION CONSTRUCTION SHALL BE ADEQUATELY PROTECTED FROM FREEZING. 13. ALL EARTHWORK INCLUDING BUT NOT LIMITED TO EXCAVATION, BACKFILL, AND COMPACTION SHALL BE DONE IN STRICT ACCORDANCE WITH THE RECOMMENDATIONS STATED IN GEOTECHNICAL INVESTIGATION REPORT OR THE REQUIREMENTS OF THE CITY OF THE PROJECT. 14. FOUNDATION EXCAVATION, BACKFILLING, AND COMPACTION SHALL BE OBSERVED AND APPROVED BY THE GEOTECHNICAL ENGINEER OF RECORD, IF APPLICABLE, AND THE GOVERNING AGENCY PRIOR TO PLACING REINFORCING STEEL AND CONCRETE. GEOTECHNICAL ENGINEER SHALL PROVIDE A LETTER OF COMPLIANCE TO THE OWNER. 15. FOR SLOT-CUTTING METHOD OF EXCAVATION, PROVIDE SUPPORTING COMPUTATIONS BY A REGISTERED GEOTECHNICAL ENGINEER AND A DRAWING SHOWING THE LOCATION OF SLOTS, THEIR WIDTH AND SEQUENCE OF SLOT CUTS. SLOT CUT TO BE AT LEAST 36" AWAY FROM ANY PROPERTY LINES AND NOT EXCEED 5 FEET IN DEPTH. 16. TEMPORARY CUT SLOPES SHALL NOT EXCEED RECOMMENDED DEPTH IN THE GEOTECHNICAL INVESTIGATION REPORT. DO NOT PERMIT ANY PERSON TO DESCEND INTO TRENCHES OR EXCAVATIONS GREATER THAN FIVE FEET IN DEPTH UNLESS NECESSARY PERMIT FROM STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY IS OBTAINED PRIOR TO ISSUANCE OF BUILDING OR GRADING PERMIT. CONTRACTOR SHALL PROVIDE FOR DESIGN, PERMIT, AND INSTALLATION OF ALL SHORING AND SHEATHING NECESSARY TO SAFELY RETAIN EARTH BANKS. 17. CONTRACTOR SHALL PROVIDE FOR DEWATERING OF EXCAVATIONS FROM SURFACE WATER, GROUNDWATER OR SEEPAGE. DEWATERING SHALL EFFECTIVELY ELIMINATE ANY HYDROSTATIC PRESSURE ON SHORING. ENSURE THAT CONTAMINATED WATER IS NOT DISPOSED OF IN PUBLIC SEWER OR STORM DRAIN SYSTEM AND ENSURE THAT DIRTY WATER IS NOT DISPOSED OF INTO PUBLIC RIGHT-OF-WAY. 18. SIDEWALKS OR PAVING IMMEDIATELY ADJACENT TO BUILDING PERIMETER SHALL BE SLOPED TO PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. LANDSCAPE IRRIGATION IS NOT PERMITTED WITHIN FIVE FEET OF BUILDING PERIMETER FOOTINGS EXCEPT WHEN ENCLOSED IN PROTECTED PLANTERS THAT DIRECT DRAINAGE AWAY FROM STRUCTURE AND FOUNDATIONS. DISCHARGE FROM DOWNSPOUTS, ROOF DRAINS, AND SCUPPERS IS NOT PERMITTED ONTO UNPROTECTED SOILS WITHIN FIVE FEET OF BUILDING PERIMETER. 19. UNLESS ADEQUATELY BRACED AND SHORED, RETAINING WALLS SHALL NOT BE BACKFILLED UNTIL WALLS HAVE ATTAINED FULL DESIGN STRENGTH. FOR PIT WALLS AND BUILDING WALLS BELOW GRADE, BRACING AND SHORING SHALL REMAIN IN PLACE UNTIL ATTACHED FLOORS ARE PLACED, CURED FOR AT LEAST 7 DAYS, AND HAVE ATTAINED 70% DESIGN STRENGTH. BACKFILL PLACED IMMEDIATELY BEHIND RETAINING WALLS SHALL BE COMPACTED WITH HAND OPERATED EQUIPMENT. 20. WHERE THE STEEL COLUMNS ARE EXPOSED TO WEATHER, BASE PLATES AND COLUMNS UP TO 12" ABOVE THE CONCRETE SLAB SHALL BE COATED WITH MIN. 2 COATS OF MACROPOXY 646. 23. ALL PERMANENT STEELS IN CONTACT WITH WEATHER SHALL BE PROTECTED FOR CORROSION. TABLE WIND-1. WIND DESIGN DATA CASE VALUE BASIC WIND SPEED 95 MPH IMPORTANCE FACTOR, Iw 1.0 EXPOSURE CATEGORY B ENCLOSURE CLASSIFICATION ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT, GCpi ±0.18 WIND BASE SHEAR IN EAST- WEST DIRECTION 4 KIPS WIND BASE SHEAR IN NORTH- SOUTH DIRECTION 3.4 KIPS TABLE EQ-1. EARTHQUAKE DESIGN DATA PARAMETER VALUE SITE CLASS D-DEFAULT IMPORTANCE FACTOR, IE 1.0 MAPPED SPECTRAL RESPONSE ACCELERATION, SS 1.295 G MAPPED SPECTRAL RESPONSE ACCELERATION, S1 0.462 G SITE COEFFICIENT, FA 1.2 SITE COEFFICIENT, FV 1.838 DESIGN SPECTRAL RESPONSE COEFFICIENT, SDS 1.036 G DESIGN SPECTRAL RESPONSE COEFFICIENT, SD1 0.566 G SEISMIC DESIGN CATEGORY D RESPONSE MODIFICATION COEFFICIENT (S) OF LIGHT- FRAME (WOOD), R 6.5 OVERSTRENGTH FACTOR (WOOD), Ω0 3 DEFLECTION AMPLIFICATION FACTOR (WOOD), CD 4 SEISMIC RESPONSE COEFFICIENT, CS 0.159 (LRFD) SEISMIC BASE SHEAR OF LIGHT- FRAME (WOOD)2.97 KIPS ANALYSIS PROCDURE ELF PROC. RESPONSE MODIFICATION COEFFICIENT (S) OF OMF (STEEL), R N/A OVERSTRENGTH FACTOR (STEEL), Ω0 N/A DEFLECTION AMPLIFICATION FACTOR (STEEL), CD N/A SEISMIC RESPONSE COEFFICIENT, CS N/A SEISMIC BASE SHEAR OF OMF (STEEL) N/A ANALYSIS PROCDURE N/A TABLE LL-1. MINIMUM LIVE LOAD RESIDENTIAL AREAS VALUE PRIVATE ROOMS AND CORRIDORS SERVING THEM 40 PSF PUBLIC ROOMS 100 PSF CORRIDORS SERVING PUBLIC ROOMS 100 PSF UNINHABITABLE ATTICS WITHOUT STORAGE 10 PSF UNINHABITABLE ATTICS WITH STORAGE 20 PSF HABITABLE ATTICS AND SLEEPING AREAS 30 PSF ALL OTHER AREAS 40 PSF BALCONIES AND DECKS 1.5 TIMES THE LIVE LOAD FOR THE AREA SERVED. NOT REQUIRED TO EXCEED 100 PSF ROOFS ORDINARY FLAT, PITCHED, AND CURVED ROOFS 20 PSF ROOF AREAS USED FOR OCCUPANTS SAME AS OCCUPANCY SERVED ROOF AREAS USED FOR ASSEMBLY PURPOSES 100 PSF 1. SAZAN'S SCOPE OF WORK IS LIMITED TO PROVIDING STRUCTURAL DRAWINGS FOR THE DEMOLISHING AND REBUILDING THE EXISTING GARAGE LIKE FOR LIKE, LOCATED AT 1011 W 2ND ST, SANTA ANA, CA 92703. 2. THE SCOPE OF WORK DOES NOT INCLUDE THE ANALYSIS OR EVALUATIONS OF EXISTING STRUCTURE AS A WHOLE OR THE PORTIONS OF IT THAT IS NOT INCLUDED IN THIS SCOPE OF WORK FOR LATERAL AND GRAVITY LOADS. NO WARRANTY EXPRESSED OR IMPLIED TO THE ADEQUACY, CODE COMPLIANCE, OR CONFORMANCE OF THE EXISTING STRUCTURE IS MADE BY VIRTUE OF THIS DESIGN. THIS SCOPE OF WORK DOES NOT INCLUDE ANY VERIFICATION FOR THE CONFORMANCE OF THE EXISTING STRUCTURE TO THE PROVIDED DOCUMENTS OR CODE COMPLIANCE. 3. SAZAN PERFORMED THE DESIGN CONSIDERING THE AVAILABLE INFORMATION FOR THE STRUCTURE. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE THAT SAZAN WAS NOT AWARE OF, OR WHICH WAS UNKNOWN AT THE TIME OF ANALYSIS OR DESIGN, SAZAN RESERVES THE RIGHT TO REVISE THE DESIGN AS NEEDED AND ADDITIONAL COSTS MAY BE REQUIRED. 4. SAZAN PERFORMED THE STRUCTURAL DESIGN IN A MANNER CONSISTENT WITH THE LEVEL OF SKILL AND CARE ORDINARILY EXERCISED BY PROFESSIONAL ENGINEERS AND CONSULTANTS PRACTICING UNDER SIMILAR CONDITIONS. NO OTHER REPRESENTATION, WARRANTY, OR GUARANTEE IS GIVEN. PROVIDED OPINIONS ARE BASED ON OUR ENGINEERING JUDGMENT. SAZAN WILL NOT BE RESPONSIBLE FOR LATENT DEFECTS THAT MAY APPEAR IN THE FUTURE OR FOR DIFFERENT OPINIONS OF OTHERS THAT MAY ARISE. 5. THE CLIENT IS SOLELY RESPONSIBLE FOR THE ACCURACY OF THE PROVIDED INFORMATION, AND STRUCTURAL ENGINEER DISCLAIMS ANY LIABILITIES FOR DISCREPANCIES BETWEEN THE DOCUMENTS THEMSELVES OR PROVIDED INFORMATION AND FIELD CONDITIONS. 6. STRUCTURAL OBSERVATION AND SPECIAL INSPECTIONS ARE NOT INCLUDED IN THIS SCOPE OF WORK. 7. ALL WORK SHALL BE INACCORDANCE WITH THE 2022 EDITION OF CALIFORNIA BUILDING CODE (CBC), CALIFORNIA RESIDENTIAL CODE (CRC), AND ALL AMENDMENTS OF THE CITY OF THE PROJECT LOCATION AND LOCAL AUTHORITIES INCLUDING LOCAL ORDINANCE. 8. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE STANDARDS FOR THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) OF PROJECT STATE AND ALL APPLICABLE LOCAL CODES AND ORDINANCES. CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR THE SAFTEY OF PERSONEL AND JOBSITE OF THIS CONTRACT DURING THE CONSTRUCTION. ENGINEER AND THE OWNER SHALL REMAIN HARMLESS FROM ANY AND ALL LIABILITIES OF THE CONSTRUCTION WORK. 9. THE JURISDICTION PERMIT SET SHALL NOT BE USED FOR ANY CONSTRUCTION OR COMMENCING THE WORK PRIOR TO ACQUIRING THE JURISDICTION’S PERMIT. SAZAN SHALL HAVE NO LIABILITY OR RESPONSIBILITY FOR THE SAFETY, AND/OR COSTS OF ANY CONSTRUCTION THAT IS PERFORMED PRIOR TO ACQUIRING THE JURISDICTION’S PERMIT. FAILURE TO OBTAIN A BUILDING PERMIT IS A VIOLATION OF CONTRACTORS LICENSE LAW. CONSTRUCTION PERFORMED WITHOUT A PERMIT CAN EXPOSE A HOMEOWNER TO ADDITIONAL LIABILITY AND COSTS. 10. CONSTRUCTION DOCUMENTS IDENTIFIED AS BID SET OR ISSUED FOR PERMIT ON ANY OR ALL SHEETS ARE SUBJECTED TO REVIEW AND APPROVAL BY BUILDING OFFICIALS. THIS REVIEW MAY RESULT CHANGES TO THE DOCUMENTS. DRAWING SETS/SHEETS THAT ARE NOT APPROVED BY BUILDING OFFICIALS SHALL NOT BE USED FOR ANY CONSTRUCTION OR COMMENCING ANY PREPARATION WORK. THESE DOCUMENTS ARE NOT CONSTRUED AS BEING THE COMPLETED OR FINAL CONSTRUCTION DOCUMENTS AND THEY SHALL NOT IN ANY WAY BE USED AS SUCH. 11. DESIGN OF HANDRAILS AND GUARDRAILS ARE NOT INCLUDED WITH THIS SCOPE OF WORK. 12. ALL GUARDRAILS AND HANDRAILS SHALL BE DESIGNED TO WITHSTAND A LATERAL POINT LOAD OF 200 POUNDS APPLIED HORIZONTALLY AT RIGHT ANGLES, AT ANY POINT TO TOP RAIL. A 50 PLF LOAD IS REQUIRED AT 3-STORY AND MULTI-FAMILY. 13. THESE DRAWINGS ARE PROVIDED SPECIFICALLY FOR THE PROJECT LISTED ON THE TITLE BLOCK AND ANY REUSE OR REPRODUCE OF THE DRAWINGS AND DETAILS AS A WHOLE, OR A PART ARE STRICTLY PROHIBITED UNLESS A WRITTEN APPROVAL FROM THE ENGINEER IS ISSUED. 14. CONTRACTOR SHALL COORDINATE FOR ALL INSPECTIONS AND SPECIAL INSPECTIONS THAT ARE REQUIRED BY LOCAL AUTHORITIES FOR THE WORK. ALL REPORTS SHALL BE SUBMITTED TO THE OWNER AND ENGINEERS PRIOR TO THE CONCLUDING OF THE WORK. ALL REPORTED DEFICIENCIES IDENTIFIED BY THE STRUCTURAL OBSERVER SHALL BE REPAIRED AT NO COSTS TO THE OWNER OR ENGINEERS PRIOR TO CONCLUSION OF WORK. 15. ALL DIMENSIONS SHALL BE VERIFIED IN FIELD PRIOR TO COMMENCEMENT OF WORK. ANY DISCREPANCIES BETWEEN THE DIMENSION SHOWN ON THESE DRAWINGS AND CIVIL DRAWINGS, ARCHITECTURAL DRAWINGS OR FIELD CONDITIONS SHALL BE REPORTED TO THE ENGINEER. ALL OPENINGS' LAYOUT, EMBEDMENTS, SLEEVES, AND PENETRATIONS FOR ARCHITECTURAL, MECHANICAL, AND ELECTRICAL ATTACHMENTS SHALL BE VERIFIED PRIOR TO PERFORMING THE WORK. NO WORK SHALL BE PERFORMED UNTIL THE DISCREPANCIES ARE RESOLVED. 16. REVIEW ALL CONTRACT DOCUMENTS FOR THE SCOPE OF WORK AND CONTRACTOR MINIMUM RESPONSIBILITIES. PROJECT DOCUMENTS INCLUDE INFORMATION REQUIRED TO CONVEY THE DESIGN INTENT. NOTIFY THE ENGINEER PRIOR TO COMMENCING OF THE WORK, IF ANY CLARIFICATIONS OF THE DESIGN ARE NEEDED. 17. THE DRAWINGS SHALL NOT BE SCALED. SPECIFIC DIMENSIONS SHOWN ON THE DRAWINGS, TAKE PRECEDENCE OVER THE SCALED DRAWINGS. 18. CONTRACTOR SHALL SCHEDULING SEQUENCE OF ALL WORK AND SUBCONTRACTORS' PLANS AND COORDINATE ALL WORK AND MAINTAIN CLEAN PATHS FOR ALL CODE REQUIRED EXITS AT ALL THE PHASES OF CONSTRUCTION. THE SCHEDULE SHALL BE APPROVED BY THE OWNER AND ARCHITECT-ENGINEER OF THE RECORD PRIOR TO COMMENCING THE WORK. 19. APPROVAL BY THE INSPECTOR DOES NOT MEAN APPROVAL OR ALLOWABLE FAILURE TO COMPLY WITH THE PLANS AND SPECIFICATIONS. ANY DESIGN WHICH FAILS TO BE CLEAR OR IS AMBIGUOUS MUST BE REFERRED TO THE DESIGNER OR ENGINEER FOR INTERPRETATION OR CLARIFICATION. 20. VIBRATION EFFECTS OF MECHANICAL EQUIPMENT HAVE NOT BEEN CONSIDERED BY SEOR. 21.DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE INSTRUCTIONS OR REQUIREMENTS OF REGULATORY AGENCIES IS TO THE LATEST PRINTED EDITION OF EACH IN EFFECT AT THE DATE OF SUBMISSION OF BID UNLESS THE DOCUMENT DATE IS SHOWN. DETAILS ON SHEETS TITLED “TYPICAL DETAILS” APPLY TO SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY REFERENCED. SUCH DETAILS ARE NOT NOTED AT EACH LOCATION THAT THEY OCCUR. 22. TYPICAL AND SIMILAR DETAILS SHALL BE CONSIDERED WHERE THE CONDITIONS ARE NOT SPECIFICALLY DETAILED. RESPONSIBILITIES OF THE CONTRACTOR INCLUDE UNDERSTANDING THE EXTENT OF THE TYPICAL DETAILS AND THEIR APPLICATION PRIOR TO PERFORMING WORK. 23.SPECIFIC NOTES AND DETAILS ON DRAWINGS TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. IF CONFLICT OCCURS BETWEEN THE CONTRACT DRAWINGS AND THE PROJECT MANUAL, IMMEDIATELY NOTIFY ARCHITECT AND STRUCTURAL ENGINEER FOR RESOLUTION. NO WORK SHALL BE PERFORMED IN THE AREA OF QUESTION TILL THE CONFLICT IS RESOLVED. 24. THE STABILITY, AND INTEGRITY OF THE STRUCTURE ARE VERIFIED AS A WHOLE. PROJECT DOCUMENTS DO NOT INDICATE MEANS AND METHODS OF THE CONSTRUCTION. CONTRACTOR SHALL TAKE REQUIRED MEASURES TO ENSURE THE STABILITY AND INTEGRITY OF THE STRUCTURE CONSIDERING ALL FIELD CONDITIONS. NEW COMPONENTS THAT ARE ADDED FOR STABILITY AND ARE NOT PART OF THE FINAL CONSTRUCTION SHALL BE REMOVED PRIOR TO CONCLUDING THE WORK. 25.DURIG THE CONSTRUCTION, ALL TEMPORARY BRACING ELEMENTS REQUIRED TO RESIST WIND, SEISMIC, SOIL PRESSURE OR OTHER LATERAL LOADS, SHALL BE MAINTAINED UNTIL THE MAIN LATERAL FORCE RESISTING SYSTEMS OF THE BUILDING AND THEIR CONNECTIONS ARE COMPLETED. PROJECT OBSERVATION PROGRAMS AND VISITS PERFORMED BY ENGINEERS AND INSPECTORS SHALL NOT BE CONSIDERED AS APPROVAL OF CONSTRUCTION MEANS AND METHODS. STRUCTURAL OBSERVATIONS DO NOT CONSTITUTE QUALITY CONTROL, DO NOT GUARANTEE CONTRACTOR'S PERFORMANCE, AND SHALL NOT BE CONSIDERED AS SUPERVISION OF CONSTRUCTION. 26.CONTRACTOR IS SOLELY RESPONSIBLE FOR PROTECTION OF ALL STRUCTURAL, NONSTRUCTURAL, ARCHITECTURAL, FINISHING, ELECTRICAL AND MECHANICAL COMPONENTS WHICH ARE NOT DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION. ANY DAMAGES CAUSED BY THE CONTRACTOR OR SUBCONTRACTORS SHALL BE REPAIRED BY THE CONTRACTOR AT NO COSTS TO THE OWNER. 27. ALL MODIFICATIONS AND SUBSTITUTIONS SHALL BE SUBMITTED FOR APPROVAL. 28. THE CONTRACTOR SHALL VERIFY EXISTING CONCEALED AND VISIBLE CONDITIONS AND SHALL MAKE NECESSARY ADJUSTMENTS TO THE SYSTEMS AND COSTS DUE TO ACTUAL FIELD CONDITIONS. UNLESS SPECIFICALLY APPROVED BY THE OWNER, ARCHITECT AND STRUCTURAL ENGINEER OF THE RECORD, AFTER AWARDING THE PROJECT, NO ADDITIONAL COSTS TO THE OWNER OR ENGINEER ARE ACCEPTED DUE TO FIELD CONDITIONS. 29.STRUCTURAL DESIGN CAPACITIES PROVIDED ON THESE DRAWINGS ARE APPLICABLE AFTER THE ALL ELEMENTS AND THEIR CONNECTIONS ARE CONSTRUCTED AND FULLY CURED. WHERE CONSTRUCTION MATERIALS ARE PLACED ON CONSTRUCTED FLOORS AND ROOFS, MATERIALS SHALL BE DISTRIBUTED SUCH THAT THE DESIGN LIVE LOAD PER SQUARE FOOT IS NOT EXCEEDED AT ANY LOCATIONS. 30.EQUIPMENT ANCHORAGE TO THE STRUCTURE SHALL BE PROVIDED BY MANUFACTURER IN ACCORDANCE WITH STATE AND CITY CODES. 31.BRACING SYSTEMS USED FOR ATTACHMENTS SHALL HAVE CURRENT APPROVAL DOCUMENTS AND EVALUATION REPORT, WHICH CONFORM TO THE GOVERNING CODE, AND AUTHORITY REQUIREMENTS. 32.SUSPENDED EQUIPMENT SHALL BE SECURED WITH APPROVED LATERAL BRACING SYSTEM HAVING CURRENT APPROVAL DOCUMENTS AND EVALUATION REPORT. 33.UNLESS NOTES OTHERWISE, LOADS FROM ELECTRICAL, MECHANICAL, AND PLUMBING ATTACHMENTS SHALL BE SUPPORTED BY STRUCTURAL BEAMS. 34.INSTALL ALL MATERIALS AND PRODUCTS SPECIFIED OR SHOWN IN THESE DRAWINGS IN STRICT CONFORMANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS. 35.REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS LAYOUT OF DOOR AND WINDOW OPENINGS IN STRUCTURAL WALLS, LOCATION AND EXTENT OF EXTERIOR WALL SYSTEM, LOCATION AND EXTENT OF NON-BEARING CMU WALLS AND LAYOUT OF OPENINGS THEREIN, LAYOUT OF SLOPES, CONCRETE CURBS, DEPRESSIONS, CHANGES IN LEVEL, CHAMFERS AND REVEALS, INSERTS FOR FINISH SYSTEMS, LAYOUT OF OPENINGS IN FLOORS AND ROOF AND SLAB EDGES,FRAMING, LAYOUT AND DETAILS STAIR SIZE AND LOCATION. 36.REFER TO ELECTRICAL, MECHANICAL, PLUMBING DRAWINGS FOR LOCATION AND SIZE OF PIPE SLEEVES, TRENCHES, AND OPENINGS THROUGH WALLS AND SLABS FOR DUCTWORK, LAYOUT, LOCATIONS AND EXTENT OF ANCHORAGE OF PIPING, ELECTRICAL CONDUITS AND DUCTWORK, TO STRUCTURE, LAYOUT, LOCATIONS, AND EXTENT OF EQUIPMENT ANCHORAGE TO STRUCTURE, EQUIPMENT PADS, AND REQUIREMENT WEIGHTS, LAYOUT, LOCATIONS, AND EXTENT OF ELECTRICAL CONDUITS, OUTLETS, AND BOXES IN CONCRETE SLABS AND WALLS. 37.UNLESS APPROVED BY THE ENGINEER, NO OPENING, HOLES, CUTS OR DISCONTINUITIES NOT SHOWN ON THE STRUCTURAL DRAWINGS AND EXTENDING INTO OR THROUGH STRUCTURAL ELEMENTS SHALL BE PERMITTED. ADDITIONAL DETAILING MAY BE REQUIRED AT THESE LOCATIONS. 38. ANY MODIFICATION TO THESE DRAWINGS OR DETAILS WITHOUT A WRITTEN APPROVAL FROM THE ENGINEER SHALL VOID THE ENGINEER’S RESPONSIBILITY FOR THE WHOLE STRUCTURE. IF ANY MODIFICATIONS ARE REQUIRED, IT SHALL BE REPORTED TO THE ENGINEER AND SHALL BE APPROVED PRIOR TO PERFORMING THE WORK. 39.DESIGN DATA DESIGN OF THE STRUCTURE IS IN ACCORDANCE WITH THE CALIFORNIA BUILDING CODE, 2022. UNLESS NOTED OTHERWISE ON THE DRAWINGS, THE DESIGN LOADS ARE AS TABLE LL-1. RESIDENTIAL AREAS RISK CATEGORY = II CODE LEVEL WIND DESIGN DATA ARE AS TABLE WIND-1. CODE LEVEL EARTHQUAKE DESIGN DATA ARE AS TABLE EQ-1. GENERAL NOTES 1 1/2" LAP SPLICE LENGTH db GA P S H A L L N O T E X C E E D TH E S M A L L E R O F 1 / 2 LA P L E N G T H A N D 6 " REINFORCEMENT AS REQD.CONCRETE NOTE: BARS ARE REPMITTED TO BE IN CONTACT WITH EACH OTHER DE V E L O P M E N T L E N G T H PE R T A B L E SURFACE OF CONCRETE OR SECTION FROM WHICH DEVELOPMENT LENGTH IS MEASURED CO V E R O N B A R E X T E N T I O N FO R 9 0 ° H O O K A SECTION A SIDE COVER FOR 90° AND 180° HOOK DEVELOPMENT LENGTH AND COVER FOR HOOKS AND BAR EXTENSION 90° HOOK db 12 d b EX T E N S I O N 6d b B E N D DI A . 180° HOOK db 6d b B E N D DI A . 2 1/2", BUT NOT LESS THAN 4db EXTENSION HOOKS FOR REINFORCEMENT IN WALLS AND FOUNDATIONS 90° HOOK db 12 d b EX T E N S I O N 4d b B E N D DI A . 135° HOOK db 4d b B E N D DI A . 6db EXTEN S I O N HOOKS FOR STIRRUPS IN LINTELS FIGURE STANDARD HOOKS FRAMING LUMBER AND ENGINEERED WOOD PRODUCT TABLE CONCOV-1. CONCRETE COVERAGE LOCATION VALUE CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" CONCRETE EXPOSED TO EARTH OR WEATHER: NO. 6 THROUGH NO. 18 BARS NO. 5 BARS, W31 OR D31 WIRE, AND SMALLER 2" 1 1/2" CONCRETE NOT EXPOSED WEATHER OR IN CONTACT WITH GROUND: SLAB, WALL, JOIST: NO. 14 AND NO. 18 BARS NO. 11 BARS AND SMALLER (*) BEAMS AND COLUMNS: PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS SLAB-ON-GRADE 1 1/2" 1" 1 1/2" AT ONE-THIRD OF THE SLAB THICKNESS FROM THE TOP SIDE (*) CONCRETE COVER FOR THESE MEMBERS MAY NOT BE ADEQUATE FOR 2 HOURS OF FIRE RATING PROJECT CLIENT 0' 2' 4' 8' 16' SHEET TITLE 1011 W 2ND ST, SANTA ANA, CA 92703 JUAN GARSIA SAZAN INC. 2610 Vista Del Oro, Newport Beach, CA 92660 S0.01 CONSTRUCTION NOTES DATE. 12/21/2023 EXP. 06-30-2024           1011 W Second St 5/1/2025 APPEARANCE GRADE WITH MOISTURE CONTENT BETWEEN 7-14 PERCENT. 5. ALL FABRICATIONS SHALL BE IN ACCORDANCE WITH AITC A190 AND PERFORMED WITH A CERTIFIED FABRICATOR AS PER AITC. 6. GLUED-LAMINATED TIMBERS SHALL HAVE INSPECTION CERTIFICATE AT NO COST TO THE OWNER, OR ENGINEER. A COPY OF THE INSPECTION CERTIFICATE SHALL BE SUBMITTED TO THE BUILDING OFFICIALS, AEOR AND SEOR. 7. UNLESS NOTED OTHERWISE, GLUE LAMINATED TIMERS SHALL NOT HAVE ANY CAMBERS. 8. ENGINEERED STRUCTURAL MEMBERS SHALL NOT BE NOTCHED, DRILLED, OR ALTERED EXCEPT AS PERMITTED BY THE MANUFACTURER'S WRITTEN RECOMMENDATIONS AND AS SPECIFICALLY SHOWN ON THESE DRAWINGS, WHICHEVER IS MORE STRICTER. TABLE FL-2. NAIL PROPERTIES SCHEDULE DESIGNATION LENGTH (IN.) WIRE DIAMETER (IN.) HEAD DIAMETER (IN.) 6d 2 0.113 0.266 8d 2-1/2 0.131 0.281 10d 3 0.148 0.312 12d 3-1/4 0.148 0.312 16d 3-1/2 0.162 0.344 20d 4 0.192 0.406 30d 4-1/2 0.207 0.438 40d 5 0.225 0.469 50d 5-1/2 0.244 0.5 60d 6 0.263 0.531 TABLE FL-3. STRUCTURAL GLUED-LAMINATED TIMBERS AND STRUCTURAL COMPOSITE LUMBER MEMBER Fb (PSI)Fv (PSI)E (x106 PSI) PSL (2.2E)PARALLAM 2900 290 2.2 LVL (2.0E)MICROLLAM LVL 2900 285 2.0 GLB 24F-V4 DF/DF GLB 2400 265 1.8 LSL TIMBERSTRAND 2325 310 1.55 TABLE FL-1. REQUIRED GRADE FOR STRUCTURAL WOOD MEMBERS: ALL STRUCTURAL WOOD MEMBERS SHALL BE DOUGLAS FIR-LARCH CONFORMING TO THE REQUIREMENTS OF WWPA OR WCLIB UNLESSE NOTE OTHERWISE ON THESE DRAWINGS JOIST 2x8 & LARGER NO.2 OR BETTER 3x NO.1 STUD 2x4 NO.2 OR BETTER 2x6 NO.2 OR BETTER PLATE 2x OR 3X NO.2 OR BETTER POST 4x10 & SMALLER NO.2 4x12 & LARGER NO.1 6x & 8x NO.1 BEAM & STRINGERS & HDR 4x10 & SMALLER NO.2 4x12 & LARGER NO.1 6x & 8x NO.1 1. STRUCTURAL OBSERVATION IS REQUIRED FOR THIS PROJECT IN ACCORDANCE WITH SECTION 1704.6 OF THE CBC 2022. STRUCTURAL OBSERVATION IS THE VISUAL OBSERVATION OF THE STRUCTURAL SYSTEM BY A LICENSED DESIGN PROFESSIONAL FOR GENERAL CONFORMANCE TO THE APPROVED CONSTRUCTION DOCUMENTS. 2. STRUCTURAL OBSERVATIONS DO NOT CONSTITUTE QUALITY CONTROL, DO NOT GUARANTEE CONTRACTOR'S PERFORMANCE, AND SHALL NOT BE CONSIDERED AS SUPERVISION OF CONSTRUCTION. 3. THE OWNER OR QWNER'S REPRESENTATIVE SHALL COORDINATE AND CALL FOR A MEETING BETWEEN THE ENGINEER OR ARCHITECT RESPONSIBLE FOR THE STRUCTURAL DESIGN, STRUCTURAL OBSERVER, CONTRACTOR, AFFECTED SUBCONTRACTORS AND DEPUTY INSPECTORS. THE PURPOSE OF THE MEETING SHALL BE TO IDENTIFY THE MAJOR STRUCTURAL ELEMENTS AND CONNECTIONS THAT AFFECT THE VERTICAL AND LATERAL LOAD SYSTEMS OF THE STRUCTURE AND TO REVIEW SCHEDULING OF THE REQUIRED OBSERVATIONS. 4. STRUCTURAL OBSERVATION DOES NOT WAIVE THE RESPONSIBILITY FOR THE REQUIRED INSPECTIONS BY THE CITY OF LEMON GROVE. 5. THE OWNER SHALL EMPLOY A LICENSED DESIGN PROFESSIONAL TO PERFORM STRUCTURAL OBSERVATION SITE VISITS, AND TO ISSUE ALL STRUCTURAL OBSERVATION REPORTS. 6. THE STRUCTURAL OBSERVER SHALL PREPARE A STRUCTURAL OBSERVATION REPORT FOR EACH STAGE OF CONSTRUCTION OBSERVED. THE CITY OF LEMON GROVE STRUCTURAL OBSERVATION REPORT” FORM, OR A SIMILARLY FORMATTED REPORT, SHALL BE USED FOR ALL STRUCTURAL OBSERVATION REPORT. 7. IF THE CITY’S FORM IS NOT USED, REPORTS SHALL BE ON STRUCTURAL OBSERVER’S LETTERHEAD, STATE SITE ADDRESS, PLAN CHECK & PERMIT NUMBERS, STAGES & ELEMENTS OBSERVED, DATE OBSERVED, & COMPLETE CONTACT INFORMATION FOR STRUCTURAL OBSERVER. 8. ALL STRUCTURAL OBSERVATION REPORTS, REGARDLESS OF FORM USED, SHALL INCLUDE THE LICENSE STAMP & SIGNATURE OF THE STRUCTURAL OBSERVER RESPONSIBLE FOR THE PROJECT. 9. EACH STRUCTURAL OBSERVATION REPORT SHALL BE GIVEN TO THE OWNER OR OWNER’S REPRESENTATIVE, PROJECT CONTRACTOR, AND THE BUILDING INSPECTOR. 10. THE CONTRACTOR SHALL RESOLVE ALL DEFICIENCIES & THE FINAL STRUCTURAL OBSERVATION REPORT ISSUED PRIOR TO FINAL INSPECTION OR ACCEPTANCE OF STRUCTURAL WORK BY THE BUILDING INSPECTOR. 11. THE FINAL STRUCTURAL OBSERVATION REPORT SHALL STATE THAT THE STRUCTURAL SYSTEM CONFORMS TO THE APPROVED CONSTRUCTION DOCUMENTS & THAT ALL PREVIOUSLY OBSERVED DEFICIENCIES HAVE BEEN CORRECTED. 12. FINAL INSPECTION OR OTHER ACCEPTANCE OF THE STRUCTURAL SYSTEM BY THE CHIEF BUILDING OFFICIAL, OR DESIGNEE, WILL NOT OCCUR UNTIL THE FINAL STRUCTURAL OBSERVATION REPORT IS RECEIVED. 13. THE LICENSED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL PREPARE ALL CONSTRUCTION DOCUMENT CHANGES RELATING TO THE STRUCTURAL SYSTEMS. REVIEW & APPROVAL OF SUCH CHANGES BY THE CHIEF BUILDING OFFICIAL, OR DESIGNEE, SHALL BE OBTAIN BY THE DESIGN PROFESSIONAL AND/OR CONTRACTOR PRIOR TO INSTALLATION AND/OR CONSTRUCTION OF SAID CHANGES. 1. AN APPROVED AGENCY, RETAINED BY OWNER AND SATISFACTORY TO STRUCTURAL ENGINEER AND GOVERNING CODE AUTHORITIES, SHALL PERFORM SPECIAL INSPECTIONS AND TESTS REQUIRED BY THE CONTRACT AND APPLICABLE CODE. THESE SPECIAL INSPECTIONS AND TESTS ARE IN ADDITION TO THE INSPECTIONS REQUIRED BY CBC SECTION 110 “INSPECTIONS”. 2. APPROVED AGENCY SHALL KEEP RECORDS OF ALL SPECIAL INSPECTIONS AND TESTS AND SHALL FURNISH REPORTS OF SPECIAL INSPECTIONS AND TESTS TO THE GOVERNING CODE AUTHORITY AND THE STRUCTURAL ENGINEER. REPORTS SHALL INDICATE WHETHER THE WORK INSPECTED OR TESTED WAS OR WAS NOT COMPLETED IN CONFORMANCE TO APPROVED CONSTRUCTION DOCUMENTS. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION. IF NOT CORRECTED, THE DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE GOVERNING CODE AUTHORITY AND THE STRUCTURAL ENGINEER PRIOR TO THE COMPLETION OF THAT PHASE OF WORK. A FINAL REPORT DOCUMENTING REQUIRED SPECIAL INSPECTIONS AND TESTS, AND CORRECTION OF DISCREPANCIES, SHALL BE SUBMITTED UPON COMPLETION OF THAT PHASE OF WORK. 3. WHERE FABRICATION OF STRUCTURAL, LOAD-BEARING OR LATERAL LOAD-RESISTING MEMBERS OR ASSEMBLIES IS BEING CONDUCTED ON THE PREMISES OF A FABRICATOR’S SHOP, SPECIAL INSPECTION OF THE FABRICATED ITEMS SHALL BE PERFORMED DURING FABRICATION. SPECIAL INSPECTIONS DURING FABRICATION ARE NOT REQUIRED WHERE WORK IS DONE ON THE PREMISES OF A FABRICATOR REGISTERED AND APPROVED BY THE GOVERNING CODE AUTHORITY TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION. FABRICATOR APPROVAL SHALL BE IN ACCORDANCE TO CBC SECTION 1704.2.5.1. ACCORDING TO 1704A.2.5.1 FABRICATOR APPROVAL IS NOT PERMITTED BY DSA-SS, DSA-SS/CC, OR OSHPD. 4. EACH CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF A MAIN WIND OR SEISMIC FORCE RESISTING SYSTEM, DESIGNATED SEISMIC SYSTEM, OR A WIND OR SEISMIC FORCE-RESISTING COMPONENT LISTED IN THE STATEMENT OF SPECIAL INSPECTION SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE GOVERNING CODE AUTHORITY AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. THE CONTRACTOR’S STATEMENT OF RESPONSIBILITY SHALL CONTAIN ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS OF INSPECTION. 5. CONTRACTOR SHALL SUBMIT MATERIAL CERTIFICATION OR LABORATORY TEST REPORTS CERTIFYING MATERIALS ARE OF IDENTIFIABLE TESTED STOCK, COMPLYING WITH PROJECT SPECIFICATIONS, TO OWNER, APPROVED AGENCY, STRUCTURAL ENGINEER AND, UPON REQUEST, TO GOVERNING CODE AUTHORITY. IF LABORATORY TEST REPORTS CANNOT BE MADE AVAILABLE, APPROVED AGENCY WILL PERFORM TESTS AS DIRECTED BY STRUCTURAL ENGINEER. CONTRACTOR SHALL PAY FOR COSTS RELATED TO TESTS AND INSPECTIONS OF UNIDENTIFIABLE MATERIALS, MATERIALS FURNISHED WITHOUT LABORATORY TEST REPORTS, MATERIALS FOUND DEFICIENT AFTER INITIAL TESTS AND INSPECTIONS, AND/OR MATERIALS REPLACING DEFICIENT MATERIALS. 6. APPROVED AGENCY SHALL SUBMIT MATERIAL TEST REPORTS INDICATING WHETHER TESTED MATERIALS ARE IN COMPLIANCE OR NONCOMPLIANCE WITH CONTRACT DOCUMENTS TO OWNER, CONTRACTOR, STRUCTURAL ENGINEER AND, UPON REQUEST, TO GOVERNING CODE AUTHORITY. 7. APPROVED AGENCY SHALL PERFORM SPECIAL INSPECTIONS IN ACCORDANCE WITH CBC SECTION 1705, SECTION 1705A “REQUIRED SPECIAL INSPECTIONS AND TESTS”AND WITH THESE DRAWINGS FOR THE FOLLOWING WORK. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL TEST AND INSPECTION REQUIREMENTS. 7.1. SOILS: SPECIAL INSPECTIONS AND TESTS OF EXISTING SITE SOIL CONDITIONS, FILL PLACEMENT AND LOAD-BEARING REQUIREMENTS SHALL BE PERFORMED IN ACCORDANCE WITH TABLE 1. THE APPROVED GEOTECHNICAL REPORT AND THE CONSTRUCTION DOCUMENTS SHALL BE USED TO DETERMINE COMPLIANCE. 7.1.1. DURING FILL PLACEMENT THE APPROVED AGENCY SHALL VERIFY THAT PROPER MATERIALS AND PROCEDURES ARE USED IN ACCORDANCE WITH THE PROVISIONS OF THE APPROVED GEOTECHNICAL REPORT. 8. APPROVED AGENCY SHALL PERFORM SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE IN ACCORDANCE WITH CBC SECTION 1705.12 FOR THE FOLLOWING WORK. 8.1. STRUCTURAL WOOD: CONTINUOUS SPECIAL INSPECTION IS REQUIRED DURING FIELD GLUING OPERATIONS OF ELEMENTS OF THE SFRS. 8.1.1. PERIODIC INSPECTION IS REQUIRED FOR NAILING, BOLTING, ANCHORING AND OTHER FASTENING OF ELEMENTS OF THE SFRS, INCLUDING WOOD SHEAR WALLS, WOOD DIAPHRAGMS, DRAG-STRUTS, BRACES, SHEAR PANELS AND HOLD-DOWNS. 8.1.2. SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING AND OTHER FASTENING TO OTHER COMPONENTS OF THE SFRS, WHERE FASTENER SPACING IS OF THE SHEATHING AT EDGES OR BOUNDARIES IS 4 IN. OR LESS. 8.2. SPECIAL INSPECTIONS ARE NOT REQUIRED FOR COLD-FORMED STEEL LIGHT-FRAME SHEAR WALLS AND DIAPHRAGMS, INCLUDING SCREW INSTALLATION, BOLTING, ANCHORING AND OTHER FASTENING TO COMPONENTS OF THE SEISMIC FORCE-RESISTING SYSTEM, WHERE EITHER OF THE FOLLOWING APPLIES: 8.2.1. THE SHEATHING IS GYPSUM BOARD OR FIBERBOARD. 8.2.2. THE SHEATHING IS WOOD STRUCTURAL PANEL OR STEEL SHEETS ON ONLY ONE SIDE OF THE SHEAR WALL, SHEAR PANEL OR DIAPHRAGM ASSEMBLY AND THE FASTENER SPACINGS AT THE EDGES ARE 4 IN. OR LESS. 8.3. ARCHITECTURAL COMPONENTS: PERIODIC SPECIAL INSPECTION IS REQUIRED FOR THE ERECTION AND FASTENING OF EXTERIOR CLADDING, INTERIOR AND EXTERIOR NONBEARING WALLS AND INTERIOR AND EXTERIOR VENEER. 8.3.1. PERIODIC SPECIAL INSPECTION IS NOT REQUIRED FOR THE FOLLOWING: 8.3.2. EXTERIOR CLADDING, INTERIOR AND EXTERIOR NONBEARING WALLS AND INTERIOR AND EXTERIOR VENEER 30 FEET OR LESS IN HEIGHT ABOVE GRADE OR WALKING SURFACE. 8.3.3. EXTERIOR CLADDING AND INTERIOR AND EXTERIOR VENEER WEIGHING 5 PSF OR LESS. 8.3.4. INTERIOR NONBEARING WALLS WEIGHING 15 PSF OR LESS. 9. CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING, POST-INSTALLED ADHESIVE ANCHORS INSTALLED HORIZONTALLY OR UPWARDLY INCLINED TO RESIST SUSTAINED TENSION LOADS, SHOTCRETE PLACEMENT, CONCRETE STRENGTH f'c > 2500psi, SPRAYED-ON FIREPROOFING, ENGINEERED MASONRY, HIGH-LIFT GROUTING, HIGH LOAD DIAPHRAGMS, SPECIAL MOMENT-RESISTING CONCRETE FRAMES, AND HELICAL PILE FOUNDATION. 10. SPECIAL INSPECTORS OR INSPECTION AGENCIES SHALL SUBMIT A SIGNED FINAL REPORT TO THE BUILDING DIVISION STATING THAT ALL ITEMS REQUIRING SPECIAL INSPECTION AND TESTING WERE FULFILLED AND REPORTED AND, TO THE BEST OF THEIR KNOWLEDGE, IN CONFORMANCE WITH THE APPROVED DESIGN DRAWINGS, SPECIFICATIONS, APPROVED CHANGE ORDERS AND THE APPLICABLE PROVISIONS OF THE CBC ITEMS NOT IN CONFORMANCE, UNRESOLVED ITEMS OR ANY DISCREPANCIES IN INSPECTION COVERAGE (I.E. MISSED INSPECTIONS, PERIODIC INSPECTIONS WHEN CONTINUOUS WAS REQUIRED, ETC.) SHOULD BE SPECIFICALLY ITEMIZED IN THIS REPORT. ALTERNATE FORMS MAY BE APPROVED BY THE BUILDING OFFICIALS. THE FINAL REPORT SHALL BE SUBMITTED AT THE SITE WITHIN SEVEN (7) DAYS OF COMPLETION OF THE JOB. 11. EMPLOYMENT OF SPECIAL INSPECTION IS THE DIRECT RESPONSIBILITY OF THE OWNER, OR THE ENGINEER/ARCHITECT OF RECORD ACTING AS THE OWNER'S REPRESENTATIVE. SPECIAL INSPECTOR SHALL BE ONE OF THOSE AS PRESCRIBED IN SEC. 1704. STRUCTURAL OBSERVATION SPECIAL INSPECTIONWALL STUD TO STUD (NOT AT BRACED WALL PANELS)16d COMMON 24” O.C. FACE NAIL STUD TO STUD AND ABUTTING STUDS AT INTERSECTING WALL CORNERS (AT BRACED WALL PANELS)16d COMMON 16” O.C. FACE NAIL BUILT-UP HEADER 16d COMMON 16” O.C. EACH EDGE, FACE NAIL CONTINUOUS HEADER TO STUD 4-8d COMMON TOENAIL TOP PLATE TO TOP PLATE 16d COMMON 16” O.C. FACE NAIL TOP PLATE TO TOP PLATE, AT END JOINTS 8-16d COMMON EACH SIDE OF END JOINT, FACE NAIL (MIN 24” LAP SPLICE LENGTH EACH SIDE OF END JOINT) BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (NOT AT BRACED WALL PANELS)16d COMMON 16” O.C. FACE NAIL BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING AT BRACED WALL PANELS 2-16d COMMON 16” O.C. FACE NAIL STUD TO TOP OR BOTTOM PLATE 4-8d COMMON TOENAIL TOP OR BOTTOM PLATE TO STUD 2-16d COMMON END NAIL TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS 2-16d COMMON FACE NAIL 1” BRACE TO EACH STUD AND PLATE 2-8d COMMON FACE NAIL 1”X6” SHEATHING TO EACH BEARING 2-8d COMMON FACE NAIL 1”8” AND WIDER SHEATHING TO EACH BEARING 3-8d COMMON FACE NAIL FLOOR JOIST TO SILL, TOP PLATE, OR GIRDER 3-8d COMMON TOENAIL RIM JOIST, BAND JOIST, OR BLOCKING TO TOP PLATE, SILL OR OTHER FRAMING BELOW 8d COMMON 6” O.C., TOENAIL 1”X6” SUBFLOOR OR LESS TO EACH JOIST 2-8d COMMON FACE NAIL 2” SUBFLOOR TO JOIST OR GIRDER 2-16d COMMON FACE NAIL 2” PLANK 2-16d COMMON EACH BEARING, FACE NAIL BUILT UP GIRDERS AND BEAMS, 2” LUMBER LAYERS 20d COMMON 32” O.C. FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE SIDES 2-20d COMMON ENDS AND AT EACH SPLICE, FACE NAIL LEDGER STRIP SUPPORTING JOISTS OR RAFTERS 3-16d COMMON EACH JOIST OR RAFTER, FACE NAIL JOIST TO BAND JOIST OR RIM JOIST 3-16d COMMON END NAIL BRIDGING OR BLOCKING TO JOIST, RAFTER OR TRUSS 2-8d COMMON EACH END, TOENAIL 2022 CBC TABLE 2304.10.2 - FASTENING SCHEDULE DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER SPACING AND LOCATION ROOF BLOCKING BETWEEN CEILING JOISTS, RAFTERS OR TRUSSES TO TOP PLATE OR OTHER FRAMING BELOW 3 - 8d COMMON TOENAIL EACH END BLOCKING BETWEEN RAFTERS OR TRUSS NOT AT THE WALL TOP PLATE, TO RAFTER OR TRUSS 2 - 8d COMMON TOENAIL EACH END 2-16d COMMON END NAIL FLAT BLOCKING TO TRUSS AND WEB FILLER 16d COMMON @6"O.C.FACE NAIL CEILING JOISTS TO TOP PLATE 3-8d COMMON TOENAIL EACH JOIST CEILING JOIST NOT ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITIONS (NO THRUST) (TABLE AND SECTION2308.7.3.1) 3-16d COMMON FACE NAIL CEILING JOISTS ATTACHED TO PARALLEL RAFTER (HEEL JOINT) (TABLE AND SECTION2308.7.3.1)7-16d COMMON FACE NAIL COLLAR TIE TO RAFTER 3-10d COMMON FACE NAIL RAFTER OR ROOF TRUSS TO TOP PLATE (TABLE AND SECTION 2308.7.5)3-10d COMMON TOENAIL (C) ROOF RAFTERS TO RIDGE VALLEY OR HIP RAFTERS; OR ROOF RAFTER TO 2” RIDGE BEAM 2-16d COMMON END NAIL 3-10d COMMON TOENAIL Structural Observation Program Designation of Structural Observation PROJECT ADDRESS: _________________________________________ PERMIT APPL. NO.__________ Description of Work: ____________________________________________________________________ Owner: _______________________ Architect: ________________________ Engineer: _______________ STRUCTURAL OBSERVATION (Only checked items are required) Firm or individual to be responsible for the Structural Observation: Name: Phone: ( FOUNDATION Footing, Stem Walls, Piers Mat Foundation Caisson, Piles, Grade Beams Stepp’g/Retaining Foundation, Hillside Special Anchors WALL Concrete Masonry Wood Others: The structure is classified as Occupancy Category III or IV. The Height of the structure is greater then 75 feet (22,860 mm) above the base. The structure is assigned to Seismic Design Category E, is classified as Occupancy Category I or II. DECLARATION BY OWNER I, the Owner of the project, declare that the above listed firm or individual is hired by me to be the Structural Observer. ) Calif. Registration: FRAME Steel Moment Frame Steel Braced Frame DIAPHRAGM Concrete Steel Deck Concrete Moment Frame Masonry Wall Frame Others: Signature ______________________________Date _________________ Declaration by Engineer or Architect of Record (required if different from the listed Structural Observer) I, the Engineer or Architect of record for the project, declare that the above listed firm or individual is designated by me to be responsible for the Structural Observation. Signature ______________________________ 300 N. Flower Street, Santa Ana, CA 92703 P.O. Box 4048, Santa Ana, CA 92702-4048 Revised 02/2017 Date __________________ www.ocpublicworks.com P: 714.667.8888 I F: 714.667.7575 ocpCustomerCare@ocpw.ocgov.com Wood 1011 W 2ND ST, SANTA ANA, CA 92703 DEMOLISHING AND REBUILDING THE EXISTING GARAGE LIKE FOR LIKE Special Inspection Program and Designation of Special Inspectors 601 N. Ross Street, Santa Ana, CA 92701 P.O. Box 4048, Santa Ana, CA 92702-4048 www.ocpublicworks.com 714.667.8888 | myOCeServices.ocgov.com □ Concrete (Design Mix, Form Work, Placement, etc., per □ Erection of Pre-Cast Concrete Members □ Bolts Installed in Concrete □ Reinforcing Steel and Pre-Stressing Steel Tendons □ StructuralWelding/Rebar Welding □ High-Strength Bolting/Material Verification □ Steel Frame Joint Details □ All Masonry Construction □ Sprayed Fire-Resistive Materials □ Shotcrete (Curing Temperature, Design Mix, Placement, Strength etc. per table 1705.3) □ Soils (Excavation, Fill, etc. per table 1705.6) □ Smoke-Control System □ Driven Piles per Table 1705.7 □ Cast in Place Piers per Table 1705.8 □ Mastic and Intumescent Fire-Resistant Coatings □ Exterior Insulation and Finish Systems (EIFS) □Wood for High-Load Diaphragms □ Others □ Others □ Others □ Others SPECIAL INSPECTIONS (Only checked items are required) INSPECTION ITEMS SPECIAL INSPECTORS(S) NAME,PHONE NUMBER,REGISTRATION# DECLARATION BY OWNER OR ARCHITECT/ENGINEER OF RECORD: I, the □ Owner □ Engineer or □ Architect of record,declare that the above listed Special Inspector(s) is/are hired by me. Print Name Signature Date 1. EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER SHALL CONFORM TO THE FOLLOWIG: 1.1. EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT SHALL CONFORM TO ASTM C847,ASTM C1032, AND ASTM C150 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C926 AND ASTM C1063.METAL LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION - RESISTANT MATERIAL.. 1.2. FASTENER TO STUDS,TOP AND BOTTOM PLATES, AND BLOCKING SHALL BE 0.120" NAIL X 1-½” LONG, 7/16" HEAD OR NO. 16 GAGE GALV. STAPLE, 7/8" LEGS. STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7/16", MEASURED OUTSIDE THE LEGS, AND SHALL BE INSTALLED WITH THEIR CROWNS PARALLEL TO THE LONG DIMENSION OF THE FRAMING MEMBERS.STAPLES FOR THE ATTACHMENT OF GYPSUM LATH AND WOVEN-WIRE LATH SHALL HAVE A MINIMUM CROWN WIDTH OF 3/4", MEASURED OUTSIDE THE LEGS. 2. ALL WALLS,FLOOR,CIELING AND ROOF GYPSUM BOARD SHALL BE AT LEAST 5/8" THICK (UNO ON ARCH. DWG.) AND CONFORM TO THE FOLLOWING REQUIREMENTS: 2.1. GYPSUM WALLBOARD SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C 840. GYPSUM BASE FOR VENEER PLASTER SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C844 BUT NOT LESS THAN THE FOLLOWING REQUIREMENTS. WATER-RESISTANT GYPSUM BACKING BOARD SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C 840. 2.2. GYPSUM BOARD OR GYPSUM PANEL PRODUCTS SHALL BE INSTALLED PERPENDICULAR TO FRAMING MEMBERS.END JOINTS OF ADJACENT COURSES OF GYPSUM BOARD SHALL NOT OCCUR ON THE SAME JOIST. 2.3. BOARDS SHALL BE CONNECTED TO THE SUPPORTING ELEMENTS (STUDS, JOISTS,RAFTERS, TOP AND BOTTOM PLATES, AND BLOCKING) WITH 6D COOLER (0.092" X 1-7/8" LONG, 1/4" HEAD) OR WALLBOARD NAIL (0.0915" X 1-7/8" LONG, 19/64" HEAD) OR 0.120" NAIL X 1-3/4" LONG, MIN 3/8" HEAD. 2.4. ALTERNATIVELY BOARDS INSTALLED ON THE WALLS MAY BE CONNECTED TO THE SUPPORTING MEMBERS WITH NO.16 GAGE GALV. STAPLE, 1-1/2" LEGS, 1-5/8" LONG. STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7/16", MEASURED OUTSIDE THE LEGS, AND SHALL BE INSTALLED WITH THEIR CROWNS PARALLEL TO THE LONG DIMENSION OF THE FRAMING MEMBERS.STAPLES FOR THE ATTACHMENT OF GYPSUM LATH AND WOVEN-WIRE LATH SHALL HAVE A MINIMUM CROWN WIDTH OF 3/4", MEASURED OUTSIDE THE LEGS. 2.5. TYPE S OR W DRYWALL SCREWS SHALL CONFORM TO REQUIREMENTS OF ASTM C 1002. 2.6. FASTENERS SHALL BE SPACED NOT MORE THAN 7 INCHES ON CENTER AT ALL SUPPORTS, INCLUDING PERIMETER BLOCKING, AND NOT MORE THAN 3/4" FROM THE EDGES AND ENDS OF THE GYPSUM BOARD OR GYPSUM PANEL PRODUCT. 2.7. PERIMETER EDGES OF ALL GYPSUM BOARDS SHALL BE BLOCKED USING A WOOD MEMBER NOT LESS THAN 2"X6" NOMINAL DIMENSION. BLOCKING MATERIAL SHALL BE INSTALLED FLAT OVER THE TOP PLATE OF THE WALL TO PROVIDE A NAILING SURFACE NOT LESS THAN 2" IN WIDTH FOR THE ATTACHMENT OF THE GYPSUM BOARD OR GYPSUM PANEL PRODUCT. 1. EXTERIOR AND INTERIOR CEMENT PLASTER AND LATHING SHALL BE DONE WITH THE APPROPRIATE MATERIALS LISTED IN TABLE BELOW. 2. EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER SHALL CONFORM TO THE FOLLOWING: 2.1 EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT SHALL CONFORM TO ASTM C847, ASTM C1032, AND ASTM C150 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C926 AND ASTM C1063. METAL LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION-RESISTANT MATERIAL. 2.2 FASTENER TO STUDS, TOP AND BOTTOM PLATES, AND BLOCKING SHALL BE 0.120" NAIL X 1-1/2" LONG, 7/16" HEAD OR NO.16 GAGE GALV. STAPLE, 7/8" LEGS. STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7/16", MEASURED OUTSIDE THE LEGS, AND SHALL BE INSTALLED WITH THEIR CROWNS PARALLEL TO THE LONG DIMENSION OF THE FRAMING MEMBERS. STAPLES FOR THE ATTACHMENT OF GYPSUM LATH AND WOVEN-WIRE LATH SHALL HAVE A MINIMUM CROWN WIDTH OF 3/4", MEASURED OUTSIDE THE LEGS. 3. MATERIALS SHALL BE STORED IN SUCH A MANNER AS TO PROTECT THEM FROM THE WEATHER. 4. INSTALLATION OF THESE MATERIALS SHALL BE IN COMPLIANCE WITH ASTM C926 AND ASTM C1063. 5. METAL LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION-RESISTANT MATERIAL. 6. BACKING OR A LATH SHALL PROVIDE SUFFICIENT RIGIDITY TO PERMIT PLASTER APPLICATIONS. 6.1 WHERE LATH ON VERTICAL SURFACES EXTENDS BETWEEN RAFTERS OR OTHER SIMILAR PROJECTING MEMBERS, SOLID BACKING SHALL BE INSTALLED TO PROVIDE SUPPORT FOR LATH AND ATTACHMENTS. 6.2 GYPSUM LATH OR GYPSUM WALLBOARD SHALL NOT BE USED AS BACKING FOR CEMENT PLASTER UNO. 7. APPROVED WATER-RESISTIVE BARRIERS SHALL BE INSTALLED AND, WHERE APPLIED OVER WOOD-BASED SHEATHING, SHALL INCLUDE A WATER-RESISTIVE VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST. EQUIVALENT TO TWO LAYERS OF WATER-RESISTIVE BARRIER COMPLYING WITH ASTM E2556, TYPE I. THE INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (SEE ARCH DWG. AND INSTALLED IN ACCORDANCE WITH SECTION 1404.4 OF CBC) INTENDED TO DRAIN TO THE WATER-RESISTIVE BARRIER IS DIRECTED BETWEEN THE LAYERS. 7.1 EXCEPTION 1: WHERE THE WATER-RESISTIVE BARRIER THAT IS APPLIED OVER WOOD-BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER THAN THAT OF A WATER-RESISTIVE BARRIER COMPLYING WITH ASTM E2556, TYPE II AND IS SEPARATED FROM THE STUCCO BY AN INTERVENING, SUBSTANTIALLY NONWATERY-ABSORBING LAYER OR DRAINAGE SPACE. 7.2 EXCEPTION 2: WHERE THE WATER-RESISTIVE BARRIER IS APPLIED OVER WOOD-BASE SHEATHING IN CLIMATE ZONE 1A, 2A OR 3A, A VENTILATED AIR SPACE SHALL BE PROVIDE BETWEEN THE STUCCO AND WATER-RESISTIVE BARRIER. 8. MASONRY AND CONCRETE SURFACES SHALL BE CLEAN, FREE FROM EFFLORESCENCE, SUFFICIENTLY DAMP AND ROUGH FOR PROPER BOND. IF THE SURFACE IS INSUFFICIENTLY ROUGH, APPROVED BONDING AGENTS OR A PORTLAND CEMENT DASH BOND COAT MIXED IN PROPORTIONS OF NOT MORE THAN TWO PARTS VOLUME OF SAND TO ONE PART VOLUME OF PORTLAND CEMENT OR PLASTIC CEMENT SHALL BE APPLIED. THE DASH BOND COAT SHALL BE LEFT UNDISTURBED AND SHALL BE MOIST CURED NOT LESS THAN 24 HOURS. TABLE 2507 - LATH, PLASTERING MATERIALS AND ACCESSORIES MATERIAL STANDARD ACCESSORIES FOR GYPSUM VENEER BASE ASTM C1047 BLENDED CEMENT ASTM C595 COLD-FORMED STEEL STUDS AND TRACK, STRUCTURAL AISI S240 COLD-FORMED STEEL STUDS AND TRACK, NONSTRUCTURAL AISI S220 EXTERIOR PLASTER BONDING COMPOUNDS ASTM C932 HYDRAULIC CEMENT ASTM C1157; C1600 GYPSUM CASTING AND MOLDING PLASTER ASTM C59 GYPSUM KEENE'S CEMENT ASTM C61 GYPSUM PLASTER ASTM C28 GYPSUM VENEER PLASTER ASTM C587 INTERIOR BONDING COMPOUNDS, GYPSUM ASTM C631 LIME PLASTERS ASTM C5;C206 MASONRY CEMENT ASTM C91 METAL LATH ASTM C847 PLASTER AGGREGATES SAND PERLITE VERMICULITE ASTM C35; C897 ASTM C35 ASTM C35 PLASTIC CEMENT ASTM C1328 PORTLAND CEMENT ASTM C150 STEEL SCREWS ASTM C1002; C954 WELDED WIRE LATH ASTM C933 WOVEN WIRE PLASTER BASE ASTM C103 1. PLASTERING WITH CEMENT PLASTER SHALL BE NOT LESS THAN THREE COATS WHERE APPLIED OVER METAL LATH OR WIRE FABRIC LATH OR GYPSUM BOARD BACKING AS SPECIFIED IN NOTE 5 AND SHALL BE NOT LESS THAN TWO COATS WHERE APPLIED OVER MASONRY OR CONCRETE. IF THE PLASTER SURFACE IS TO BE COMPLETELY COVERED BY VENEER OR OTHER FACING MATERIAL, OR IS COMPLETELY CONCEALED BY ANOTHER WALL, PLASTER APPLICATION NEED ONLY BE TWO COATS, PROVIDED THAT THE TOTAL THICKNESS IS AS SET FORTH IN ASTM C926. 2. ON WOOD FRAME OR STEEL STUD CONSTRUCTION WITH AN ON-GRADE CONCRETE FLOOR SLAB SYSTEM, EXTERIOR PLASTER SHALL BE APPLIED IN SUCH A MANNER AS TO COVER, BUT NOT TO EXTEND BELOW, THE LATH AND PAPER. THE APPLICATION OF LATH, PAPER AND FLASHING OR DRIP SCREEDS SHALL COMPLY WITH ASTM C1063. 3. A MINIMUM 0.019-INCH (NO. 26 GALVANIZED SHEET GAGE), CORROSION-RESISTANT WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3.5 IN. SHALL BE PROVIDED AT OR BELOW THE FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH ASTM C926. THE WEEP SCREED SHALL BE PLACED NOT LESS THAN 4 IN. ABOVE THE EARTH OR 2 IN. ABOVE PAVED AREAS AND BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING. THE WATER-RESISTIVE BARRIER SHALL LAP THE ATTACHMENT FLANGE. THE EXTERIOR LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED. 4. ONLY APPROVED PLASTICITY AGENTS AND APPROVED AMOUNTS THEREOF SHALL BE ADDED TO PORTLAND CEMENT OR BLENDED CEMENTS. WHERE PLASTIC CEMENT OR MASONRY CEMENT IS USED, ADDITIONAL LIME OR PLASTICIZERS SHALL NOT BE ADDED. HYDRATED LIME OR THE EQUIVALENT AMOUNT OF LIME PUTTY USED AS A PLASTICIZER IS PERMITTED TO BE ADDED TO CEMENT PLASTER OR CEMENT AND LIME PLASTER IN AN AMOUNT NOT TO EXCEED THAT SET FORTH IN ASTM C926. 5. GYPSUM PLASTER SHALL NOT BE USED ON EXTERIOR SURFACES. 6. CEMENT PLASTER COATS SHALL BE PROTECTED FROM FREEZING FOR A PERIOD OF NOT LESS THAN 24 HOURS AFTER SET HAS OCCURRED. PLASTER SHALL BE APPLIED WHEN THE AMBIENT TEMPERATURE IS HIGHER THAN 40°F, UNLESS PROVISIONS ARE MADE TO KEEP CEMENT PLASTER WORK ABOVE 40°F DURING APPLICATION AND 48 HOURS THEREAFTER. 7. THE SECOND COAT SHALL BE BROUGHT OUT TO PROPER THICKNESS, RODDED AND FLOATED SUFFICIENTLY ROUGH TO PROVIDE ADEQUATE BOND FOR THE FINISH COAT. THE SECOND COAT SHALL NOT HAVE VARIATIONS GREATER THAN 1/4 IN. IN ANY DIRECTION UNDER A 5-FOOT STRAIGHT EDGE. 8. FIRST AND SECOND COATS OF CEMENT PLASTER SHALL BE APPLIED AND MOIST CURED AS SET FORTH IN ASTM C926 AND TABLE BELOW. a. THE FIRST TWO COATS SHALL BE AS REQUIRED FOR THE FIRST COATS OF EXTERIOR PLASTER, EXCEPT THAT THE MOIST-CURING TIME PERIOD BETWEEN THE FIRST AND SECOND COATS SHALL BE NOT LESS THAN 24 HOURS. MOIST CURING SHALL NOT BE REQUIRED WHERE JOB AND WEATHER CONDITIONS ARE FAVORABLE TO THE RETENTION OF MOISTURE IN THE CEMENT PLASTER FOR THE REQUIRED TIME PERIOD. b. TWENTY-FOUR-HOUR MINIMUM INTERVAL BETWEEN COATS O INTERIOR CEMENT PLASTER. OTHER METHODS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL. c. FINISH COAT PLASTER IS PERMITTED TO BE APPLIED TO INTERIOR CEMENT PLASTER BASE COATS AFTER A 48-HOURS PERIOD. 9.WHERE APPLIED DIRECTLY TO UNIT MASONRY SURFACES, THE SECOND COAT IS PERMITTED TO BE APPLIED AS SOON AS THE FIRST COAT HAS ATTAINED SUFFICIENT HARDNESS. 10. THE SECOND COAT IS PERMITTED TO BE APPLIED AS SOON AS THE FIRST COAT HAS ATTAINED SUFFICIENT RIGIDITY TO RECEIVE THE SECOND COAT. 10.1 WHERE USING THIS METHOD OF APPLICATION, CALCIUM ALUMINATE CEMENT UP TO 15 PERCENT OF THE WEIGHT OF THE PORTLAND CEMENT IS PERMITTED TO BE ADDED TO THE MIX. 10.2 CURING OF THE FIRST COAT IS PERMITTED TO BE OMITTED AND THE SECOND COAT SHALL BE CURED AS SET FORTH IN ASTM C926 AND TABLE 2512.6. 11. CEMENT PLASTER FINISH COATS SHALL BE APPLIED OVER BASE COATS THAT HAVE BEEN IN PLACE FOR THE TIME PERIODS SET FORTH IN ASTM C926. THE THIRD OR FINISH COAT SHALL BE APPLIED WITH SUFFICIENT MATERIAL AND PRESSURE TO BOND AND TO COVER THE BROWN COAT AND SHALL BE OF SUFFICIENT THICKNESS TO CONCEAL THE BROWN COAT. TABLE 2512.6 CEMENT PLASTERS COAT MINIMUM PERIOD MOIST CURING MINIMUM INTERVAL BETWEEN COTTS FIRST 48 HOURS 48 HOURS SECOND 48 HOURS 7 DAYS FINISH - NOTE C 1. ALL WALLS,FLOOR,CIELING AND ROOF GYPSUM BOARD SHALL BE AT LEAST 5/8" THICK (UNO ON ARCH. DWG.) AND CONFORM TO THE FOLLOWING REQUIREMENTS: 1.1 GYPSUM WALLBOARD SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C 840. GYPSUM BASE FOR VENEER PLASTER SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C844 BUT NOT LESS THAN THE FOLLOWING REQUIREMENTS. WATER-RESISTANT GYPSUM BACKING BOARD SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C 840. 1.2 GYPSUM BOARD OR GYPSUM PANEL PRODUCTS SHALL BE INSTALLED PERPENDICULAR TO FRAMING MEMBERS. END JOINTS OF ADJACENT COURSES OF GYPSUM BOARD SHALL NOT OCCUR ON THE SAME JOIST. 1.3 BOARDS SHALL BE CONNECTED TO THE SUPPORTING ELEMENTS (STUDS, JOISTS,RAFTERS, TOP AND BOTTOM PLATES, AND BLOCKING) WITH 6D COOLER (0.092" X 1-7/8" LONG, 1/4" HEAD) OR WALLBOARD NAIL (0.0915" X 1-7/8" LONG, 19/64" HEAD) OR 0.120" NAIL X 1-3/4" LONG, MIN 3/8" HEAD. 1.4 ALTERNATIVELY BOARDS INSTALLED ON THE WALLS MAY BE CONNECTED TO THE SUPPORTING MEMBERS WITH NO.16 GAGE GALV. STAPLE, 1-1/2" LEGS, 1-5/8" LONG. STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7/16", MEASURED OUTSIDE THE LEGS, AND SHALL BE INSTALLED WITH THEIR CROWNS PARALLEL TO THE LONG DIMENSION OF THE FRAMING MEMBERS. STAPLES FOR THE ATTACHMENT OF GYPSUM LATH AND WOVEN-WIRE LATH SHALL HAVE A MINIMUM CROWN WIDTH OF 3/4", MEASURED OUTSIDE THE LEGS. 1.5 TYPE S OR W DRYWALL SCREWS SHALL CONFORM TO REQUIREMENTS OF ASTM C 1002. 1.6 FASTENERS SHALL BE SPACED NOT MORE THAN 7 INCHES ON CENTER AT ALL SUPPORTS, INCLUDING PERIMETER BLOCKING, AND NOT MORE THAN 3/4" FROM THE EDGES AND ENDS OF THE GYPSUM BOARD OR GYPSUM PANEL PRODUCT. 1.7 PERIMETER EDGES OF ALL GYPSUM BOARDS SHLL BE BLOCKED USING A WOOD MEMBER NOT LESS THAN 2"X6" NOMINAL DIMENSION. BLOCKING MATERIAL SHALL BE INSTALLED FLAT OVER THE TOP PLATE OF THE WALL TO PROVIDE A NAILING SURFACE NOT LESS THAN 2" IN WIDTH FOR THE ATTACHMENT OF THE GYPSUM BOARD OR GYPSUM PANEL PRODUCT. GYPSUM BOARD AND EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER (STUCCO) NOTES LATHING AND FURRING FOR CEMENT PLASTER EXTERIOR PLASTER GYPSUM BOARD PROJECT CLIENT 0' 2' 4' 8' 16' SHEET TITLE 1011 W 2ND ST, SANTA ANA, CA 92703 JUAN GARSIA SAZAN INC. 2610 Vista Del Oro, Newport Beach, CA 92660 S0.02 CONSTRUCTION NOTES DATE. 12/21/2023 EXP. 06-30-2024           1011 W Second St 5/1/2025 1" CLEAR SLEEVE AROUND PIPE CAULK PIPE TRENCH PIPE NOTES: 1. DEPTH OF FOUNDATIONS MAY BE DETERMINED BY LOCATION OF PIPE. 2. GENERAL CONTRACTOR SHALL CONSULT WITH MECHANICAL CONTRACTOR TO DETERMINE DEPTH AND LOCATION OF PIPES. 3. NO PIPE INSIDE THE THICKENED PART OF FOUNDATION. 4. WHERE PIPES CROSS UNDER THE FOUNDATION AND ARE NOT MORE THAN 3' BELOW THE FOUNDATION, EXCAVATION SHALL BE EXTENDED TO PIPE AND FILLED WITH MASS CONC. 1" CLEAR SLEEVE AROUND PIPE CAULK F5 SCALE:NTS. PIPE THRU FOUNDATION 18" MIN. 6" NO EXCAVATION BELOW LINES NO EXCAVATION BELOW LINES 6" MI N . 6" MI N . B WALL FOUNDATION 2" OF APPROVED HIGHLY COMPRESSIBLE MATERIAL AROUND PIPE RUNS PROVIDE 2500 PSI CONC. BACKFILL WHERE EXCAVATION RUNS ACROSS AND UNDER THE LINE OF FOUNDATION WHEN "B" EXCEEDS 6'-0" FOOTING SHALL BE STEPPED DN. FROM BOTH SIDES PIPES CROSSING BENEATH CONT. WALL FOUNDATION SCALE:NTS. 7 F t ³t 2 STRIP FOUNDATION W/ CURB W/ SB/SSTB ANCHOR SCALE:NTS. SB SEE 8/S1.01 11 1 4" M A X . Le 13 4" 16" MIN. 12 " M I N . PLAN VIEW 6" 4" MIN.4" MIN. 24" MIN. 12" MIN. 24 " M I N SLAB NOT SHOWN FOR CLARITY NOTE: FOUNDATION DETAILS AND REINFORCEMENT ARE NOT SHOWN FOR CLARITY. SEE FOUNDATION DETAILS FOR THE BALANCE OF INFORMATION AND DETAILS THAT ARE NOT SHOWN 134" F 1 1 2"12" MIN. 6" (FOR HDU14) ADD EXTRA #4 BARS EA. SIDE OF HOLD DOWN 112" 6" (F O R HD U 1 4 ) NOTE: THE DIAMOND-SHAPED JOINTS (6) MAY BE OMITTED IF COLUMN FOOTINGS ARE BELOW FLOOR LEVEL AND THE COLUMN IS WRAPPED WITH TWO LAYERS OF SHEATHING MEMBRANE OR JOINT FILLER TO BREAK THE BOND. 1. CONTROL JOINTS WITHIN 3050MM (120 IN). OF CORNERS 2. SPACING OF JOINTS 6100MM (240 IN). MAX. CONTROL JOINTS IN FLOOR SLAB 3. FLOOR SLAB JOINT IN FLOOR SLAB 4. CONTROL JOINTS AROUND COLUMN FOOTINGS (SEE NOTE) 5. FLOOR SLAB JOINT SPACING OF 6 M (20 FT.) MAXIMUM 6. CONTROL JOINT AROUND COLUMN FOOTINGS (SEE NOTE) 2 1 1 5 3 3 4 6 3 5 LOCATION OF CONTROL JOINTS F SCALE:NTS. 6 8" MI N . 1 3/4" HOLD DOWN ANCHOR SCHEDULE AT FOUNDATION F SCALE:NTS. 8 HDU2 1/4x2.5 6 4"x4"2,960 LB SSTB 16 5/8"17 20" HDU4 1/4x2.5 10 4"x4"4,500 LB SSTB 20 5/8"18 22" HDU5 1/4x2.5 14 4"x4"5,600 LB SSTB 24 5/8"18 22" HDU8 1/4x2.5 20 4"x4"6,970 LB SSTB 28 7/8"25 28" HDU11 1/4x2.5 30 4"x8"9,535 LB SB1x30 1"24 28" HDU14***1/4x2.5 36 4"x8"13,090 LB SB1x30**-18*1"24, F**=17 28" HD19 1" BOLT 5 6"x6"19,070 LB PAB10 1 1/4"14.5,F=22 24" HOLD DOWN TYP. SDS SCREW SIZE (IN.) NO. OF SCREWS MIN. WOOD POST SIZE DESIGN CAPACITY ANCHOR TYPE DIA.Le, F(IN.)MIN. FON. DEPTH LSTHD8 0.148x3.25 16 4"x4"1,600 LB 8 12" STHD10 0.148x3.25 20 4"x4"2,100 LB 10 14" STHD14 0.148x3.25 24 4"x4"3,500 LB 14 18" HDU2 1/4x2.5 6 4"x4"3,000 LB SSTB 16 5/8"13 16" HDU4 1/4x2.5 10 4"x4"4,500 LB SSTB 20 5/8"17 22" HDU5 1/4x2.5 14 4"x4"5,600 LB SSTB 24 5/8"21 26" HDU8 1/4x2.5 20 4"x6"6,900 LB SSTB 28 7/8"25 28" HDU11 1/4x2.5 30 4"x8"11,100 LB SB1x30 1"24 28" HDU14***1/4x2.5 36 4"x8"13,000 LB SB1x30**-18*1"24, F**=17 28" HD19 1" BOLT 5 6"x6"19,070 LB PAB10 1 1/4"14.5,F=22 24" NOTE: *WHERE NOTED, SB1x30 REQUIRES FOUNDATION WIDTH TO BE 18" WIDE. **PAB8 SOLUTION MAY ALSO BE USED. FOR PAB8 COVERAGE ON EACH SIDE OF THE BOLT SHALL BE MINIMUM F". ***WOOD MEMBER SHALL BE 8"x4" OR LARGER 1. ANCHORS DESIGNATED AS ASTM A193 GRADE B7 THREADED RODS TO USE ASTM A563 GRADE DH HEAVY HEX NUTS AND ASTM F436 WASHERS. ANCHOR RODS SHALL CONFORM TO ASTM A36 THREADED RODS W/ ASTM A563 GRADE A NUTS AND ANSI B18.22.1 TYPE A WASHERS, UNLESS OTHERWISE NOTED. 2. ALL NUTS SHALL BE HOT DIP OR MECHANICAL ZINC COATED, GRADE A FINISH, HEAVY HEX AND CONFORM TO ASTM A563 W/ F436 WASHERS, UNO. MIDWALL/CORNER GARAGE CURB SCALE:NTS. 3 MI N . ( t 4,1 1 4") PROVIDE 1/4" SAWCUT OR 1/8" WIDE TOOLED JOINT WITHIN 24 HOUR OF POUR, FILL W/ SEALANT AS REQD. AS PER ARCH. DWG. SEE JOINT FILLER DETAILS 4" THICK (MIN.) BASE OF 1/2" CLEAN AGGREGATE ASTM 1745 (10 MIL) MOISTURE BARRIER MEMBRANE SOG PER PLAN t/ 2 CONTRACTION JOINT t F 1 STRIP FOUNDATION W/ CURB (GARAGE) SCALE:NTS. 4 GARAGE TO DRIVEWAY DETAIL SCALE:NTS. UNDISTURBED NATURAL SOILS OR ENGINEERED FILL ELASTOMETRIC JOINT SEALANT SEE ARCH DWG DRIVEWAY 3" C L R . 3" CLR. SOG PER PLAN DOWELS TO MATCH SOG REINF. F F (2)#5 TOP & BOT PER PLAN6" (1)#5 CURB BEYOUND 24 " M I N . SEE CIVIL/ARCH. DWG. FOR UNDER SLAB LAYER (1)#4 24" 24 " SLOP PER ARCH. DWG. 1 3 4" UNDISTURBED NATURAL SOILS OR ENGINEERED FILL ALL TOP & BOT BARS IN FOUNDATION SHALL HAVE STANDARD HOOKS AT THE ENDS. SOG PER PLAN VAPOR RETARDER SEE ARC./CIVIL DWG. (2)#5 TOP & BOT STD. HOOK t 2x UC4A OR HIGHER SILL PLATE 3x UC4A AT SHEAR WALLS P.T. STUD WALL PER PLAN UNO PER SHEAR WALL SCHED. #4@16" O.C. DOWELS SE E CI V I L / A R C H . DW G . 8" MIN. SEE CIVIL/ARCH. DWG. 1 1/ 2 " CL R ELASTOMETRIC JOINT SEALANT SEE ARCH DWG 3" C L R . 3" CLR. PER PLAN 5/8" DIA. @ 48" W/ 7" MIN.EMBED. UNO IN SHEAR WALL SCHEDULE (2)#4 WHERE CURB EXT. WALL SHEATHING 3" MIN. 6" MIN. 24" 24 " E.N. SLOPE PER ARCH. DWG. 3" CLR. DOWELS TO MATCH SOG REINF. 1 PROJECT CLIENT 0'2'4'8'16' SHEET TITLE 1011 W 2ND ST, SANTA ANA, CA 92703 JUAN GARSIA SAZAN INC. 2610 Vista Del Oro, Newport Beach, CA 92660 S1.01 TYPICAL S.O.G. AND FOUNDATION DETAILS 11/19/2024 EXP. 06-30-2026 1011 W Second St 5/1/2025 TYPICAL SHEARWALL SCHEDULE1 W SCALE: NTS. W SCALE: NTS.5 NOTE: PRESSURE TREAT ALL SILLS BRG. ON CONC. OR MAS. BLOCK. 9" M A X . 6" M I N . SILL PLATE DETAIL WHERE ANCHOR ROD CONFLICTS W/ STUDS/COMPRESSION POST PLAN 9" MAX. 6" MIN. 9" MAX. 6" MIN. 9" MAX. 6" MIN. 5" MAX. 5" MAX. ANCHOR ROD 12 " M I N . PROVIDE 1 1/2"x1/8" STRAP W/(4)16d EA. SIDE OF NOTCH OR HOLE WHERE NOTCH OR HOLE IS MORE THAN 1/3 WIDTH OF SILL PLATE 5/8" ANCHOR ROD @4'-0" O.C. MAX. W/STD. WASHER 7" MIN. EMBED. UNO IN SHEAR WALL SCHEDULE END OF SILLPLATE SILL PLATE 1" MIN. THREADBP/BPS 5/8" (3"x3"x1/4")2x STUDS PER PLAN FOUNDATION REINFORCING NOT SHOWN FOR CLARITY PROVIDE HOT DIPPED GALV. ANCHOR ROD AND PLATE WASHERS PER PROJECT SPECIFICATIONS 2x PLATE W/(4)16d 2x BLK'G W/(2)16d TYPICAL (2)16d END NAILS NOTE 1. PANELS SHALL NOT BE LESS THAN 4'X8', EXCEPT AT BOUNDARIES AND CHANGE IN FRAMING. ALL EDGE OF PANELS SHALL BE SUPPORTED BY AND FASTENED TO FRAMING MEMBERS OR BLOCKING. 2. ALL SHEAR WALL ARE BLOCKED SHEAR WALLS AND ALL JOINTS IN SHEATHING SHALL OCCUR OVER AND BE FASTENED TO COMMON FRAMING MEMBERS OR COMMON BLOCKING. 3. SHEATHING SHALL NOT BE USED TO SPLICE BOUNDARY ELEMENTS. ALL POSTS, STUDS AND COLUMNS SHALL BE FRAMED TO PROVIDE FULL END BEARING. 4. STEEL PLATE WASHERS MAY BE SLOTTED DIAGONALLY WITH A WIDTH OF UP TO 3/16" LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NO TO EXCEED 1-3/4" PROVIDED THAT A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND NUT. 5. CONTRACTOR SHALL REVIEW ALL TYPICAL SHEAR WALL CONNECTION DETAILS PRIOR TO START CONSTRUCTION. 6. STRUCTURAL PLYWOOD PANELS SHALL BE INSTALLED PRIOR TO ALL THE INSTALLATION OF ANY FRAMING THAT MAY INTERRUPT THE CONTINUITY OF THE PLYWOOD. 7. SHEAR WALL SHEATHING SHALL BE 15/32" CD, CC OR BETTER PLYWOOD. W/ ALL EDGES BLOCKED AND NAILED PER THE SHEAR WAIL SCHEDULE. 8. TYPICAL FASTENERS: 10d COMMON U.N.O. NAILS EXPOSED TO THE EXTERIOR SHALL BE GALVANIZED. 9. FRAMING: 2X D.F. TYP. @16" O.C.(MAX.) 10. FRAMING & BLOCKING AT ADJOINING PANEL EDGES SHALL BE 3” NOMINAL OR WIDER AND NAILS SHALL BE STAGGERED IN TWO ROWS ALONG PANEL EDGES WHERE SPACING IS 3” OR LESS ON CENTER. SHEAR WALL FRAMING AND STUDS SHALL BE CONTENTIOUS BETWEEN THE BOTTOM PLATE AND TOP PLATE. 11. END NAIL STUDS TO SILL PLATE WITH (2) 20d BOX NAIL INSTEAD OF (2) 16d COMMON NAILS. 12. IF NEW ANCHOR BOLTS "REQUIRED AT EXISTING FOUNDATION. PROVIDE 5/8” X MIN. 12” EMBEDMENT INTO EXISTING CONCRETE EPOXIED ANCHOR BOLTS SPACING SHOWN AT SHEAR WALL SCHEDULE. PROVIDE 3”X3”X1/4” PLATE WASHER. 13. CONTRACTOR TO VERIFY THE EXISTING PLYWOOD EDGE NAILING. TYPE OF PLYWOOD USED AND SPACING ON EXISTING ANCHOR BOLTS IN FILED, TYPICAL. 14. SPECIAL INSPECTION BY INSPECTOR REQUIRED FOR HOLD-DOWN INSTALLATION INTO EXISTING FOUNDATION. 15. SPECIAL INSPECTION IS REQUIRED FOR STRUCTURAL WOOD SHEAR WALL COMPONENTS WITH NAIL SPACING CLOSER THAN 4” OC PER CBC 1705.11.2. 16. ALL NAILS SHALL BE COMMON NAILS. PROVIDE HOT DIPPED GALVANIZED NAILS AT ALL FIRE TREATED OR PRESSURE TREATED PLYWOOD AND STUDS. 17. WHERE PLYWOOD IS APPLIED ON BOTH FACES OF A WALL AND NAIL SPACING IS LESS THAN 6" O.C. ON EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3" NOMINAL OR THICKER AND NAILS ON EACH SIDE BE STAGGERED. 3x FRAMING SHALL BE USED AT BOTTOM SILL PLATE AND ALL BLOCKING. ELEVATION WALL LENGTH AS SPECIFIED ON PLANS UPPER FLOOR LEVEL 5 S1.21 NOTE: ALTERNATE 1/2" GAP PLYWD. JOINT AT EXT. CONDITION, LOCATED AT JST. MID-HEIGHT TRIMMERS PER TYPICAL STUD WALL FRAMING AT OPENING DETAIL TYPICAL PROVIDE EDGE NAILING (E.N.) AT ALL PANEL EDGES TYPICAL PROVIDE FIELD NAILING (F.N.) AT ALL OTHER SUPPORTS BOUNDARY POST, SEE PLANS AND ANCHOR TABLE T.O. CONC. 1/4" GAP (PLYWD. TO T.O. CONC.) 3x (MIN.) SILL PLATE (P.T.D.F.) 2x STUDS @16" O.C. U.N.O. SHT'G SEE SCHEDULE 3x STUD AT ALL ADJOINING PANEL EDGES 3x BLK'G AT ALL ADJOINING PANEL EDGES DOUBLE T.PLATES ALTERNATE STAGGERED NAILING JST. OR BLK'G (SEE PLAN FOR JST. DIRECTION) FOR SDS SCREWS, USE MIN. 2x BLK'G OR RIM JST. SILL PLATE NAILINGS OR SIMPSON SDS SCREWS TO JST. OR BLK'G SEE SCHEDULE (2) 2x OR 3x SILL PLATE OPENING WHERE OCCURS 8x D A MI N . 12 " M I N . ANCHOR ROD 1" MIN. THREAD **15/32" STRUCTURAL I OSB CAN BE USED INSTEAD OF 15/32" PLYWOOD BP/BPS 58" (3"x3"x14") ***SIMPSON THDB62100H SHALL BE USE FOR ANCHORING INTO THE EXISTING FOUNDATION, UNO ON PLANS SWXB 18. NAILS SHALL BE PLACED AT LEAST 3/8" FROM PANEL EDGES AND ENDS AT LEAST 1/2" FROM THE EDGE OF THE CONNECTING MEMBERS. 19. SIMPSON 'LTP4' FRAMING ANCHOR MAY BE APPLIED OVER 1/2" SHEATHING WITH 8d COMMON NAILS IN LIEU OF 8d X1- 1/2" NAILS. 20. INDICATES SHEATHING OCCURS ON BOTH SIDES OF WALL AS SHOWN ON PLAN. 21. SHEATHING NAILS OR OTHER APPROVED SHEATHING CONNECTORS SHALL BE DRIVEN SUCH THAT THEIR HEAD OR CROWN IS FLUSH WITH THE SURFACE OF THE SHEATHING. OVER-DRIVEN NAILS WILL BE DEEMED UNSATISFACTORY. 22. PROVIDE A SINGLE 3X NOMINAL OR WIDER FRAMING MEMBER AT BOTTOM SILL PLATE AND BEHIND VERTICAL AND HORIZONTAL EDGES, MINIMUM 1/2" EDGE NAILING DISTANCE AT PANEL ENDS AND EDGES, AND STRUCTURAL OBSERVATION PER GENERAL NOTES. 23. PL1/4''X3''X3" CAN BE USED IN 6" WALLS WHEN STAGGERED. 24. ANCHOR BOLT WASHERS SHALL BE EXTENDED TO WITHIN 1/2 " OF THE EDGE OF THE BOTTOM PLATE ON THE SIDES WITH SHEATHING. 25. THE HOLE IN THE PLATE WASHER IS PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3/16" LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT TO EXCEED 1-3/4", PROVIDED THAT A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. 26. WHEN FASTENERS CONNECTING THE TWO FRAMING MEMBERS ARE SPACED LESS THAN 4" IN CENTER, THEY SHALL BE STAGGERED. 27. WHERE ANY OF THE FOLLOWING CONDITIONS OCCUR, THE WIDTH OF THE NAILED FACE OF A COMMON FRAMING MEMBER OR BLOCKING AT ADJOINING PANEL EDGES SHALL BE 3" NOMINAL OR GREATER AND NAILING SHALL BE STAGGERED AT ALL PANEL EDGES: 27.1. NAIL SPACING OF 2" ON CENTER AT ADJOINING PANEL EDGES IS SPECIFIED, OR 27.2. 10D COMMON NAILS HAVING PENETRATION INTO FRAMING MEMBERS AND BLOCKING OF MORE THAN 1-1/2" ARE SPECIFIED AT 3" ON CENTER,OR LESS AT ADJOINING PANEL EDGES, OR 27.3.THE NOMINAL UNIT SHEAR CAPACITY OF THE SHEAR WALL EXCEEDS 350 PLF.PROVIDE 3X SILL/BOT PLATE AND FRAMING MEMBERS FOR SHEAR WALLS WHERE ALLOWABLE SHEAR VALUE EXCEEDS 350 PLF. NO PENETERATION OR CUTTING IS ALLOW IN THE SHEAR WALL PANELS AND STUDS JST. OR BLK'G ANCHORS TO DOUBLE T.PLATES, SEE SCHEDULE AT 4" WALLS: PROVIDE 1/4"X3"X3" STEEL WASHER UNDER EACH NUT. AT 6" WALLS: PROVIDE 1/4"X5"X5" STEEL WASHER UNDER EACH NUT. ALL STEEL PARTS SHALL BE HOT DIPPED GALVANIZED SHEAR WALL SCHEDULE SEE NOTE 10 W SCALE: NTS. PENETRATION INTO THE TOP PLATE SECT. A : HFS INSTALLED OVER DOUBLE T.PLATES A - ALTERNATE 1 : HFS INSTALLED TO UNDERSIDE OF DOUBLE T.PLATES A - ALTERNATE 2 : HFS SEPARATED INTO TWO "L" SHAPES TO ALLOW FOR INSTALLATION OVER WD. STR. PANEL SHEATHING OR FOR INSTALLATION AT 2X6 AND GREATER WALL DEPTHS. NOTE: 1. MAX. CLEAR SPAN SPLICE IS 4 1/2" 2. FASTENER QUANTITY IS THE NUMBER OF 16d COMMON NAILS TO BE INSTALLED AT EA. END OF THE SPLICE. 3. WHEN THE DISTANCE FROM THE SPLICE TO THE FIRST NAIL HOLE IS LESS THAN 1" , OMIT THE (2) NAILS IN THE 3" SIDE PLATE AND THE (1) NAIL IN THE 1 1/2" SIDE PLATE CLOSEST TO THE SPLICE. 4. FOR THE HFS24 THAT IS INSTALLED W/ (22) 16d COMMON NAILS ON EA. END OF THE SPLICE (44 TOTAL) THERE IS NO REDUCTION IN THE VALUES. 5. FOR THE HFS36 THAT IS INSTALLED W/ (31) 16d COMMON NAILS ON EA. END OF THE SPLICE (62 TOTAL) THERE IS NO REDUCTION IN THE VALUES. 6. THE 133 COLUMN MAY BE USED FOR WIND AND EARTHQUAKE LOADING. 7. THE 160 COLUMN MAY BE USED FOR WIND ONLY. 8. THE PRODUCT AND INSTALLATION SHALL COMPLATEY W/ LA RR #25759 9. PROVIDE HARDY SADDLE WHERE PLUMBING RISERS PENETRATE BRG. OR SHEAR WALL PLATES TABLE 8.1 : HARDY FRAME ® SADDLE MODEL NUMBER FASTENERS ALLOWABLE TENSION (LBS) ALLOWABLE COMPRESSION (LBS) (TOTAL) (100) (133) (160) (100) (133) (160) HFS24 (24)16d COMMON 2948 3921 4717 1969 2618 2733 HFS36 (32)16d COMMON 4288 5703 5785 1969 2618 2733 ALTERNATE 2ALTERNATE 1SECTION A A OMIT FASTENERS AT THESE HOLES WHEN THE END DISTANCE IS LESS THAN 1" CLEAR SPAN 1 1/2" MAX. 2 10d @6:12 SIMPSON SDS25600 @ 14" O.C. ALT 16d @ 4" O.C. 310 PLF (ASD) 2x BLK. & STUD AT ALL EDGES 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) 10d @6:12 10d @4:12 10d @2:12 10d @4:12 10d @3:12 10d @2:12 UPPER FLOOR SILL PLATE NAILING ANCHOR ROD SPACING WALL CAPACITY (REDUCE 10% FOR FIRE TREATED WOOD SEE NOTES) NAILINGMATERIALTYP. SW3B SW4B SW2B SW4 SW2 SW1 SW1A (EDGE:FIELD) W/ MIN. 1 1/2'' PENETRATION W/ MIN. 1 1/2'' PENETRATION W/ MIN. 1 1/2'' PENETRATION W/ MIN. 1 1/2'' PENETRATION W/ MIN. 1 1/2'' PENETRATION W/ MIN. 1 1/2'' PENETRATION W/ MIN. 1 1/2'' PENETRATION SIMPSON SDS25600 @ 4'' O.C. 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) BOTH SIDES 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) BOTH SIDES 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) BOTH SIDES SIMPSON SDS25600 @ 14" O.C. ALT 16d @ 4" O.C. SIMPSON SDS25600 @ 9" O.C. ALT 16d @ 3 1/2" O.C. SIMPSON SDS25600 @ 4'' O.C. SIMPSON SDS25600 @ 3'' O.C. SIMPSON SDS25600 @ 2'' O.C. STAGGERED 340 PLF (ASD) 2x BLK. & STUD AT ALL EDGES 510 PLF (ASD) 3x BLK. & STUD W/ STGG. NAIL AT ALL EDGES 870 PLF (ASD) 3x BLK. & STUD W/ STGG. NAIL AT ALL EDGES 1020 PLF (ASD) 3x BLK. & STUD W/ STGG. NAIL AT ALL EDGES 1330 PLF (ASD) 3x BLK. & STUD W/ STGG. NAIL AT ALL EDGES 1740 PLF (ASD) 3x BLK. & STUD W/ STGG. NAIL AT ALL EDGES 10d @3:12SW3W/ MIN. 1 1/2'' PENETRATION SIMPSON SDS25600 @ 6'' O.C. 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) 665 PLF (ASD) 3x BLK. & STUD W/ STGG. NAIL AT ALL EDGES SIMPSON A35 @16" O.C. ALT. SIMPSON LTP4 @16" O.C. SIMPSON A35 @10" O.C. ALT. SIMPSON LTP4 @10" O.C. SIMPSON A35 @8" O.C. ALT. SIMPSON LTP4 @8" O.C. SIMPSON A35 @6" O.C. ALT. SIMPSON LTP4 @6" O.C. SIMPSON A35 @5" O.C. ALT. SIMPSON LTP4 @5" O.C. SIMPSON A35 @8" O.C. EA. SIDE ALT. SIMPSON LTP4 @8" O.C. EA. SIDE SIMPSON A35 @6" O.C. EA. SIDE ALT. SIMPSON LTP4 @6" O.C. EA. SIDE SIMPSON A35 @22" O.C. ALT. SIMPSON LTP4 @22" O.C. 5/8"ø @32" O.C. W/7" EMBEDMENT (2 MIN.) 5/8"ø @32" O.C. W/7" EMBEDMENT (2 MIN.) 5/8"ø @24" O.C. W/7" EMBEDMENT (2 MIN.) 5/8"ø @18" O.C. W/7" EMBEDMENT (3 MIN.) 5/8"ø @16" O.C. W/7" EMBEDMENT (3 MIN.) 5/8"ø @12" O.C. W/7" EMBEDMENT (3 MIN.) 5/8"ø @9" O.C. W/7" EMBEDMENT (3 MIN.) 5/8"ø @32" O.C. W/7" EMBEDMENT (2 MIN.) 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) SILL/BOT PLATE 2x 3x 3x 3x 2x 3x 3x 3x SHEAR TRANSFER AT DOUBLE TOP PLATE COMPRESSION SIDE λ = 6" MIN. WHEN L/D>11, OR L/D MIN. WHEN L/D<11 NOTE: FOR BEAM DEPTH OF 3-1/2, 5-1/2, AND 7-1/4", THE MAXIMUM HOLE DIAMETER IS 3/4, 1-1/8, AND 1-1/2", RESPECTIVELY. FOR DEEPER BEAMS, THE MAXIMUM HOLE DIAMETER IS 2". THE MAXIMUM NUMBER OF HOLES FOR EACH SPAN IS LIMITED TO 3. HOLES SHOULD NOT BE CUT IN CANTILEVERS. (A) SQUARE END BRG. COMPRESSION SIDE (B) SLOPE END BRG.(C) SLOPED END CUT FOR ROOF DRAINAGE MAX. 1/3 OF THE SPAN (D) COMPRESSION SIDE NOTCH 0.4D MAX. De> 0.6D MAX. 1/3 OF THE SPAN <0.5D D (E) TENSION SIDE NOTCH 0.1D MAX. De> 0.9D D ZONES WHERE HOR. HOLES ARE PERMITTED FOR PASSAGE OF WIRES, CONDUIT, ETC. PERMISSABLE HOR. ROUND HOLE LOCATIONS FOR LVL BEAMS UNDER UNIFORM LOADS D D <0.5D D D De> 0.6D L/3 L/3 L/3 MIN. HOR. SPACING= 2x DIA. OF THE LARGEST HOLE CUTTING, NOTCHING AND BORING IN ENGINEERED WOOD BEAMS (LVL, PSL, LSL)4 W SCALE: NTS. D ZONES WHERE 1" OR SMALLER DIA. HOR. HOLES ARE PERMITTED FOR PASSAGE OF WIRES, CONDUIT, ETC. A) THE MAX. NUMBER OF HOLES FOR EA. SPAN SHALL NOT EXCEED 3 AND B) THE HOLE MUST NOT BE CUT IN CANTILEVERS. ZONES WHERE 1" OR SMALLER DIA. HOR. HOLES ARE PERMITTED IN A UNIFORMLY LOADED BEAM (D> 7-1/4") L MIN. 2x DIA. OF THE LARGEST HOLE Y Y Y D/ 3 D/ 3 D/ 3 D/ 3 D/ 3 D/ 3 FLOOR TO FLOOR CONNECTION BY MSTA & MSTC STRAP MODEL NO. CLEAR SPAN (IN.) FASTENERS TOTAL (IN.)ALLOWABLE TENSION LOAD (DF/SP) MSTA49 18 (26) 0.148 x 2 1/2 2,020 MSTC28 18 (12) 0.148 x 3 1/4 1,150 MSTC40 18 (28) 0.148 x 3 1/4 2,690 MSTC52 18 (44) 0.148 x 3 1/4 4,225 MSTC66 18 (64) 0.148 x 3 1/4 5,850 MSTC78 18 (76) 0.148 x 3 1/4 5,850 MST37 18 (20) 0.162 x 2 1/2 2,460 MST48 18 (32) 0.162 x 2 1/2 3,950 MST60 18 (46) 0.162 x 2 1/2 6,235 MST72 18 (62) 0.162 x 2 1/2 6,730 W SCALE: NTS. FLOOR TO FLOOR TIE INSTALLATION SHOWING 3 CU T L E N G T H CL E A R S P A N EN D L E N G T H EN D L E N G T H SHEATHING NOT SHOWN FOR CLARITY. PROVIDE MIN. 1 1/6" END DISTANCE FOR CS AND CMST EQUAL NUMBER OF SPECIFIED NAILS IN EA. END ADDITIONAL NAILS ARE REQUIRED IN THE RIM BOARD AREA PROJECT CLIENT 0' 2' 4' 8' 16' SHEET TITLE 1011 W 2ND ST, SANTA ANA, CA 92703 JUAN GARSIA SAZAN INC. 2610 Vista Del Oro, Newport Beach, CA 92660 S1.21 TYPICAL WOOD DETAILS DATE. 12/21/2023 EXP. 06-30-2024           1011 W Second St 5/1/2025 1 W SCALE: NTS. EXT. WALL ELEVATION (FOR SHEARWALL, SEE SHEARWALL DETAIL) 2 MIN. DIM. OF HEADER FOR NON-LOAD BRG. WALL NOTES: 1. HEADER SCHEDULE SHALL NOT BE USED AT LOCATION WHERE HEADERS SUPPORT OTHER STRUCTURAL ELEMENTS SUCH AS BRG. WALLS, BEAMS, OR POSTS. 2.SPANS OVER 12' TO BE SPECIFICALLY SHOWN ON THE PLANS. 3.(2)2X OR (3)2X MAY BE USED IN-LIEU OF 4X & 6X MEMEBERS RESPECTIVELY. W SCALE: NTS.3 W SCALE: NTS. POST SPLICE CONNE. DETAIL POST SEE PLAN SIMPSON A34 W/ SDS SCREW EA. SIDE JOIST SEE PLAN FOR DIRECTION POST SEE PLAN (2)2x TOP PLATE PROVIDE SOLID BRG. UNDER POST/JACK STUD SILL PLATE 2x STUD WHERE OCCUR 2x STUD WHERE OCCUR SIMPSON A34 OPTION I NOTE: 1. NAILS CONNECTING SIMPSON DTC CLIP TO JOIST SHALL BE HAMMERED NEARLY FLUSH, NOT COMPLETELY FLUSH. NAILS CONNECTING SIMPSON DTC CLIP TO TOP PLATE SHALL BE HAMMERED FLSUH. 2. AT CONTRACTOR'S OPTION PROVIDE (1)2x TOP PLATE AND (1)1x TOP PLATE IN LIEU OF (2)2x TOP PLATES. GAP SHALL BE GREATER THE 1/2" BUT LESS THAN OR EQUAL TO 1 IN. 3. 2x BLK'G AT PLYWOOD JOINTS OR WHERE WALL EXCEEDS 10'-0" IN HEIGHT SIMPSON DTC NON-LOAD BRG. PARTITIONS CONNE. 16d@48" O.C. 4 W SCALE: NTS. SHEATHING PER PLAN NON-LOAD BRG. STUD WALL (2) 2 X SILL PLATE OR 3X SILL PLATE (2)2x TOP PLATE SEE NOTE #2 16d@48" O.C. SHEATHING PER PLAN NON-LOAD BRG. STUD WALL (2) 2 X SILL PLATE OR 3X SILL PLATE (2)2x TOP PLATE SEE NOTE #2 SIMPSON "DTC" CLIP @48"OC w/ (4)8d NAILS TO BASE AND (2)8d NAILS TO JOIST SEE NOTE 1 10d@4" O.C. AT BLK'G PROVIDE 2x BLK'G (DEPTH TO SUIT) BTWN. WOOD JOISTS @48" O.C. (MAX.) 2x STUD SEE ARCH. FOR SIZE AND SPACING 2x STUD SEE ARCH. FOR SIZE AND SPACING 1" C L R . 1" C L R . NON-LOAD BRG. PARTITIONS CONNE.5 W SCALE: NTS. NOTE: 1. AT CONTRACTOR'S OPTION PROVIDE (1)2x TOP PLATE AND (1)1x TOP PLATE IN LIEU OF (2)2x TOP PLATES. GAP SHALL BE GREATER THE 1/2" BUT LESS THAN OR EQUAL TO 1 IN. 2. 2x BLK'G AT PLYWOOD JOINTS OR WHERE WALL EXCEEDS 10'-0" IN HEIGHT 3. INSTALL SDPW PER SIMPSON RECOMMENDATION. OPTION II 16d@48" O.C. SHEATHING PER PLAN NON-LOAD BRG. STUD WALL (2) 2 X SILL PLATE OR 3X SILL PLATE 16d@48" O.C. SHEATHING PER PLAN NON-LOAD BRG. STUD WALL (2) 2 X SILL PLATE OR 3X SILL PLATE SIMPSON SDPW SCREW @ 48" O.C. PROVIDE 2x BLK'G W/ (3)10d FROM PLYWOOD 2x STUD SEE ARCH. FOR SIZE AND SPACING (2)2x TOP PLATE1/ 2 " M I N . 3 / 4 " M A X . GA P 34" OFFSET WHERE NON-BRG. STUD WALL OCCURS ABV. ONLY, PROVIDE 2X6@48" O.C. IN LIEU OF 2X BLOCK NON-LOAD BRG. STUD WALL SIMPSON SDPW SCREW @ 48" O.C. 1/ 2 " M I N . 3 / 4 " M A X . GA P 34" OFFSET 3/ 4 " M I N . SHEATHING PER PLAN (2)2x TOP PLATE OR (1)2x + (1)1x TOP PLATES SIMPSON SDPW SCREW USE SDPW19600 FOR (2)2x TOP PLATES AND SDPW14600 FOR (1)2x + (1)1x TOP PLATES 1/ 2 " M I N . 3 / 4 " M A X . GA P 34" OFFSET 3/ 4 " M I N . 3/8" PRE-DRILLED HOLE THROUGH TOP PLATES ONLY SUPPORTING MEMBER OVERHEAD 10 " SIMPSON THDB62100H SIMPSON HOLDOWNSIMPSON LSTHSIMPSON A35 SIMPSON CCQANCHOR ROD 1" MIN. THREAD 12 " M I N . BP/BPS 5/8" (3"x3"x1/4") SIMPSON CBSIMPSON A34 NOTE: 1. FOR CLARITY, ONLY TYPICAL CONNECTIONS ARE SHOWN *NOT MORE THAN SPECIFIED SPACING FOR ANCHOR ROD ON SHEAR WALL SCHEDULE. 2. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLKG SHALL BE PROVIDED AT PLYWD JOINTS FOR ALL WALLS. 3. THE HOLE IN THE PLATE WASHER IS PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3/16"LARGER THAN THE BOLT DIAMETER AND A SOLT LENGTH NOT TO EXEED 1-3/4",PROVIDED THAT A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. 4. FOR THE BALANCE OF NAILING, SEE CBC TABLE 2304.10.1 ON SHEETS S0 SERIES. 4 1/2" MIN. 12" MAX. TYP. AT ALL DISCONTINUOUS SILL PLATES* TYP. DBL TOP PLATE FACE NAILING 16d@16" O.C. (4)16d AT CORNERS PARTITIONS, TYP. (3)8d COMMON TOENAIL EA. JOIST FLOOR OR ROOF SHEATHING SEE PLAN BLK'G OR CONTINUOUS RIM JOIST (4)8d COMMON TOENAIL 16d@12"OC AT CORNER STUDS CORNER STUDS PER TYP. DETAIL TYP. EXT. SHEATHING W/ EN. @ 6" O.C. & FINAL @ 12" O.C., UNO DOUBLE 2x JACK STUD & KING STUDS FOR SPANS GREATER THAN 6'-0" 2x STUDS @ 16"OC UNO 16d @ 12"OC AT DBL KING STUD & JACK STUD SEE NOTE 2 DOUBLE 2x SILL FOR OPNG. OVER 6'-0"PL. SPLICE POST POST CAP SEE PLAN SIMPSON A35, SHEAR TRANSFER CLIPS OR NAILING SEE PLAN & SHEARWALL TABLE (2)2x TOP PLATE 8x D A MI N . 4' MAX. UNO L<8'-1" SIMPSON A34 EA. END SIMPSON A34 EA. ENDPL. SPLICE 4'-0" MIN. SIMPSON A34 EACH END C.L. SPLICE AT UPPER PLATE C.L. SPLICE AT LOWER PLATE SIMPSON MSTA 49 EA. SIDE (2) SIMPSON MSTA49 (2)16d EA. SIDE OF SPLICE THDB62100H BP/BPS 5/8-3 SIMPSON A34 FOUNDATION ATTACH JACK STUD TO KING STUD W/ 16d@12" OC STAGGERED, TYP. SIMPSON A34 EACH END SIMPSON A34 EACH END SIMPSON CB SIMPSON A34 SIMPSON A34 W/ SD SCREW 2x WINDOW SILL WHERE OCCURS (2)2x SILL AT OPNG. WIDER THAN 4'-0") 2x WINDOW SILL WHERE OCCURS (2)2x SILL AT OPNG. WIDER THAN 4'-0") SIMPSON A35 SOLID BLOCKING UNDER ABOVE POSTS SOLID BLOCKING UNDER ABOVE BEAMSSOLID BLK'G UNDER ABV. POSTS (2)10d TOE NAILS (ADD SIMPSON A34 AT OPENING WIDER THAN 6'-0") SIMPSON A34 W/ SD SCREW,TYP.4 1/2" MIN. 12" MAX.* 4 1/2" MIN. 12" MAX.*4 1/2" MIN. 12" MAX. TYP. AT ALL DISCONTINUOUS SILL PLATES* 4 1/2" MIN. 12" MAX. TYP. AT ALL DISCONTINUOUS SILL PLATES* SIMPSON A34 SIMPSON A35 4 1/2" MIN. 12" MAX. TYP. AT ALL DISCONTINUOUS SILL PLATES* PROVIDE STUD BELOW SPLICE PROVIDE STUD BELOW SPLICE OPENING OPENING OPENING OPENING OPENING (4) 16d COMMON NAILS, TYP. SIMPSON MSTA49 ON EACH JACK STUD UNO PER PLAN(TYP.) TYPICAL (2)16d END NAILS 2x PLATE W/(4)16d 2x BLK'G W/(2)16d HEADER SCHEDULE (SEE NOTES BELOW) UNLESS NOTED OTHERWISE ON PLANS OPG. WIDTH MIN. HEADER SIZE MIN. NUM. OF FULL HEIGHT STUD MIN. NUM. OF JACK STUDNON-BRG. INT. WALL ≤4'-0"4x4/4x6 FLAT 2 2 4'-0"≤W≤6'-0"4x6/6x6 2 2 6'-0"≤W≤8'-0"4x8/6x8 2 2 8'-0"≤W≤10'-0"4x10/6x10 3 3 10'-0"≤W≤12'-0"4x12/6x12 3 3 BEAM PER PLAN PROJECT CLIENT 0' 2' 4' 8' 16' SHEET TITLE 1011 W 2ND ST, SANTA ANA, CA 92703 JUAN GARSIA SAZAN INC. 2610 Vista Del Oro, Newport Beach, CA 92660 S1.22 TYPICAL WALL DETAILS DATE. 12/21/2023 EXP. 06-30-2024           1011 W Second St 5/1/2025 W SCALE: NTS.1 DETAIL A PLAN NOTE: ALL BLOCKED AND UNBLOCKED DIAPHRAGMS (ROOF AND FLOOR) SHALL BE CONSTRUCTED AS FOLLOWS: 1. REVIEW THE PLAN NOTES AND DRAWINGS FOR ADDITIONAL REQUIREMENTS OF FLOOR AND ROOF CONSTRUCTIONS. 2. WOOD STRUCTURAL PANELS SHALL CONFORM TO THE REQUIREMENTS FOR THEIR TYPE IN DOC PS 1 OR DOC PS2. 3. WHERE DIAPHRAGMS ARE DESIGNATED AS BLOCKED, ALL JOINTS IN SHEATHING SHALL OCCUR OVER AND BE FASTENED TO COMMON FRAMING MEMBERS OR COMMON BLK'G. THE SIZE AND SPACING OF FASTENERS AT WOOD-FRAME DIAPHRAGM BOUNDARIES AND PANEL EDGES SHALL BE AS SPECIFIED ON THESE DWGS. 4. PANELS SHALL NOT BE LESS THAN 4' X 8' EXCEPT AT BOUNDARIES AND CHANGES IN FRAMING WHERE MIN. PANEL DIMENSION SHALL BE 24" UNLESS ALL EDGES OF THE UNDERSIZED PANELS ARE SUPPORTED BY AND FASTENED TO FRAMING MEMBERS OR BLK'G. INDIVIDUAL SHEET OF SHEATHING SHALL NOT BE LESS THAN 2'-0" IN THEIR LEAST PLAN DIMENSION NOR LESS THAN 8 SQ.FT. IN AREA. 5. PANEL EDGES SHALL HAVE APPROVED TONGUE-AND-GROOVE JOINTS OR SHALL BE SUPPORTED W/ BLK'G. 6. FOR UNBLOCKED DIAPHRAGMS, THE BLK'G BTWN. SUPPORTING STRUCTURAL MEMBERS AT PANEL EDGES IS NOT REQD. 7. NAILS SHALL BE LOCATED AT LEAST 3/8" FROM THE EDGES OF PANELS.MAX. NAIL SPACING AT PANEL EDGES SHALL BE 6" ON CENTER. 8. NAILS ALONG INTERMEDIATE FRAMING MEMBERS AND BLK'G FOR PANELS SHALL BE THE SAME SIZE AS INSTALLED AT THE PANEL EDGES. 9. MAX. NAIL SPACING SHALL BE 6" ON CENTER WHEN SUPPORT SPACING OF 48" ON CENTER IS SPECIFIED AND 12" ON CENTER FOR CLOSER SUPPORT SPACINGS. 10. THE WIDTH OF THE NAILED FACE OF FRAMING MEMBERS AND BLK'G SHALL BE 2" NOMINAL OR GREATER AT ADJOINING PANEL EDGES EXCEPT THAT A 3" NOMINAL OR GREATER WIDTH AT ADJOINING PANEL EDGES AND STAGGERED NAILING AT ALL PANEL EDGES ARE REQD. WHERE: 10.1. 10.1. NAIL SPACING OF 2-1/2" ON CENTER OR LESS AT ADJOINING PANEL EDGES IS SPECIFIED, OR 10.2. 10D COMMON NAILS HAVING PENETRATION IN-TO FRAMING MEMBERS AND BLK'G OF MORE THAN 1-1/2" ARE SPECIFIED AT 3" ON CENTER OR LESS AT ADJOINING PANEL EDGES. 11. SPECIFIED STRAPS OR HOLDOWN SYSTEM SHALL BE USED TO SPLICE THE WALL TOP PLATES, SILL/BOT PLATES, BEAMS OR OTHER DRAG ELEMENTS. SHEATHING SHALL NOT BE USED TO SPLICE THE PLATES OR BEAMS. 12. TONGUE-AND-GROOVE SHEATHING SHALL BE INSTALLED W/ THE TONGUES UP ON SLOPED OR PITCHED ROOFS W/ PATTERN FACES DOWN. 13. WHERE RAFTER OR JOIST. LAP SPLICE OCCURS AND PLYWOOD JOINT IS CONTINUES,SEE DETAIL B. BRIDGING/BLK'G IS REQD. AT 96" O.C.MAX. SEE DETAILS C AND D. 14. SHEATHING NAILS OR OTHER APPROVED SHEATHING CONNECTORS SHALL BE DRIVEN SUCH THAT THEIR HEAD OR CROWN IS FLUSH W/ THE SURFACE OF THE SHEATHING OVER-DRIVEN NAILS SHALL NOT BE PERMITTED AND SHALL BE DEEMED UNSATISFACTORY. 15. AT UNBLOCKED DIAPHRAGMS, NAIL SPACING AT DIAPHRAGM BOUNDARIES AND SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6” O.C.AND FIELD NAILING SHALL NOT BE SPACED MORE THAN 12”O.C. 16. AT BLOCKED DIAPHRAGMS,NAIL SPACING AT DIAPHRAGM BOUNDARIES AND AT ALL CONTINUES PANEL EDGES SHALL NOT BE MORE THAN 6 IN. NAIL SPACING AT ALL OTHER PANEL EDGES SHALL NOT BE MORE THAN 6 IN. CONT. PANEL JOINT IN BOTH DIRECTIONS SHALL NOT BE PERMITTED. FIELD NAILING SHALL NOT BE SPACED MORE THAN 12” O.C. NOTE: THE LOWER ENDS OF CROSS BRIDGING SHALL BE DRIVEN UP AND NAILED AFTER THE SHEATHING HAS BEEN NAILED. JST. PER PLAN FIELD NAILING B.N. AT ALL CONT. PANEL EDGES PROVIDE 2x BLK'G PER DETAIL A AT BLOCKED DIAPHRAGM DISCONT. EDGE NAILINGB.N. SHEATHING SEE PLAN STAGG E R END J O I N T S 4'-0" T Y P . 2'-0" M I N . METAL CROSS BRIDGING PER TJI MANUFACTUREREDGE NAILING TJI PER PLAN 2x4 CONT. W/ 16d@12" O.C. RAFTER OR JOIST. BEYOND AT LAP SPLICE EDGE NAILING SHEATHING JOINT SHEATHING JOINTEDGE NAILING 2x4 FLAT BLK'G W/ (2)10d TOENAILS EA. END RAFTER OR JOIST PER PLAN2x BRIDGING (FULL HEIGHT) 1 1/2" EDGE NAILING 5/16" MAX. 2 1/2" EDGE NAILING 13/16" MAX. 3" EDGE NAILING 1-1/16" MAX.TWO 2x-FRAMING3x-FRAMING2x-FRAMING 1/8" GAP TYP. 3/8" MIN. TYP. FLOOR OR ROOF DIAPHRAGM SHEATING REQUIREMENTS DETAIL B DETAIL C DETAIL D 1/8" GAP TYP. 3/8" MIN. TYP. 1/8" GAP TYP. 3/8" MIN. TYP. DETAIL E SCALE: NTS. W2 W'≥MAX. (WIDTH, HEIGHT, 12'') NOTES: OPENINGS IN HOR. DIAPHRAGMS IN SEISMIC DESIGN CATEGORIES B, C, D AND E W/ A DIMENSION THAT IS GREATER THAN 4 FT (1219 MM) SHALL BE CONSTRUCTED W/ METAL TIES AND BLK'G IN ACCORDANCE W/ THIS SECTION. METAL TIES SHALL BE NOT LESS THAN 0.058" [1.47 MM (16 GALV. GAGE)] IN THICK. BY 1 1/2" (38 MM) IN WIDTH AND SHALL HAVE A YIELD STRESS NOT LESS THAN 33,000 PSI (227 MPA). BLK'G SHALL EXTEND NOT LESS THAN THE DIMENSION OF THE OPNG. IN THE DIRECTION OF THE TIE AND BLK'G. TIES SHALL BE ATTACHED TO BLK'G IN ACCORDANCE W/ THE MANUFACTURER'S INSTRUCTIONS BUT W/ NOT LESS THAN EIGHT 16d COMMON NAILS ON EA. SIDE OF THE HEADER-JOIST INTERSECTION. FLOOR OPENING w, 48" MAX. 24 " M A X . TIE AND BLK'G EQ. TO THE DIMENSION OF OPNG. OPNG. IN ROOF OR FLOOR 4x BLK'G AT STRAP LOCATION (TYP.) JOISTS OR RAFTERS TIE AND BLK'G EQ. TO THE DIMENSION OF OPNG. HANGER PER PLAN CONT. STRAP W/ BLK'G MIN. W/2 BEYOND OPNG. DOUBLE CONT. ROOF RAFTER W/ E.N.W' W' D/ 6 M A X . D/ 3 M A X . 2" M I N . D/ 4 M A X . A T E N D S SQUARE HOLES AND NOTCHED NOT RECOMMENDED D/ 6 M A X . MAX. LENGTH=D/3 OUTER 1/3 OF SPAN MIDDLE 1/3 OF SPAN: NOTCHING NOT PERMITTED OUTER 1/3 OF SPAN NOTES: FOR LUMBER BEAM: 1. UNLESS PERMITTED BY MANUF. , CUTS, NOTCHES AND HOLES BORED IN TRUSSES, STRUCTURAL COMPOSITE LUMBER, STRUCTURAL GLUE-LAMINATED MEMBERS,CROSS-LAMINATED TIMBER MEMBERS OR I JOISTS SHALL NOT BE PERMITTED. 2. CLEAR DISTANCE BTWN. THE HOLES SHALL NOT BE LESS THAN THE GREATEST OF TWO TIMES THE ADJACENT HOLES, D/3 AND 2". 3. ALL NOTCHES SHOULD BE SEALED W/ A WATER-REPELLENT SEALER, IMMEDIATELY AFTER CUTTING. 4. ROUND THE SQUARE CORNER OF THE NOTCH TO A MIN. 1/2" RADIUS. 5. THE TENSION SIDE OF MEMBERS W/ 4" OR GREATER IN NOMINAL THICK. SHALL NOT BE NOTCHED EXCEPT AT THE ENDS OF THE MEMBERS. FOR ENGINEERED WOOD BEAM(LVL,PSL,LSL): 1. PLEASE SEE MANUFACTURERS' CATALOGUES/ SPECIFICATIONS. D JOIST DEPTH AT TAPER CUT D/ 4 M A X . D NOT LESS THAN 3 1/2" CANTILEVER NOT TO EXCEED 24" 2" M I N . 2" MIN.Ø≤D/3 2" M I N JOIST SIZE MAX. HOLE MAXIMUM NOTCH DEPTH MAXIMUM END NOTCH 2x4 NONE NONE NONE 2x6 1 1/2 7/8 1 3/8 2x8 2 3/8 1 1/4 1 7/8 2x10 3 1 1/2 2 3/8 2x12 3 3/4 1 7/8 2 7/8 CUTTING, NOTCHING AND BORING IN LUMBER BEAMS AND RAFTERS W3SCALE: NTS. D/4 M A X . 2" M I N . D 5 W SCALE: NTS. BUILT UP POST 134"134" 312" 112" 112" 6" 6" 212" W SCALE: NTS.4 BEAM TO POST CONNECTION DETAIL INT. CONDITIONEND CONDITION SPLICE WHERE OCCURS AT C.L. OF POST SIMPSON MSTC40 STRAP WHERE OCCURS BEAM PER PLAN SIMPSON ECCQ POST CAP SIMPSON CCQ POST CAP SIMPSON ECCQ POST CAP SIMPSON CCQ POST CAP COLUMN PER PLAN W SCALE: NTS.6 W SCALE: NTS.7 W SCALE: NTS.8 RIDGE BEAM TO RAFTER CONNECTION RIDGE BEAM PER PLAN ROOF RAFTERS PER PLAN SIMPSON MSTA24 @48" O.C. LRUZ SIMPSON SLOPED HANGER PER PLAN ROOF SHT'G PER PLAN FILLER SIMPSON LRUZSIMPSON MSTA SHEAR TRANSFER AT ROOF SIMPSON H2.5ASIMPSON A35 CEILING JOIST PER PLAN WHERE OCCUR A35 EACH BLOCK U.O.N. PER SHEAR WALL SCHEDULE H2.5A INSTALLED AT 48" O.C. (OR AT PLYWOOD EDGE JOINTS) MI N . 6 " E.N. ROOF SHT'G PER PLAN ROOF RAFTER PER PLAN (7)16d MIN. COMMON NAILS EA. END. SHEAR WALL PER PLAN PLY WOOD MAY OTHER SIDE DBL. 2xTOP PLATE 2xRIM 2xBLK'G 2xSTUD WALL PER PLAN SHEAR TRANSFER AT GABLE ROOF H2.5A INSTALLED AT 48" O.C. (OR AT PLYWOOD EDGE JOINTS) SIMPSON A34 DOUBLE JOIST 2x BLOCKING(2 BAYS) @ 48" O.C. W/ (3)16d EACH END ROOF RAFTER PER PLAN SIMPSON A35 @ 16"O.C. U.N.O. SEE SHEAR WALL SCHEDULE CEILING JOIST PER PLAN 2x LEDGER W/ 2 ROWS OF SDWS22400DB TO EACH STUD 2x STUD PER PLAN SHEATHING PER PLAN 2x CANTILEVERED JOIST PERPENDICULAR TO ROOF RAFTER @ 16"O.C. W/ (3)-40d NAILING 2x SOLID BLOCKING W/ SIMPSON A35 @ 16" O.C. U.N.O. SEE SHEAR WALL SCHEDULE (2) 2x TOP PLS 4x BLOCKING SHEAR WALL PER PLAN B.N LESSER OF ("L" OR 2'-0")L" 2x BLK'G @48" O.C. (2-BAYS) SIMPSON A35 E.N. SIMPSON A34 SIMPSON H2.5A BALLOON WALL 16d@6" O.C. E.N. E.N. 112" 312" 112" 312" 8" 8" 112" 112"112" USE ROW OF STAGGERED 30d COMMON WIRE NAILS (D=0.207'', L=4 1/2'') FOR 3-PLY USE ROW OF STAGGERED 10d COMMON WIRE NAILS (D=0.148'' , L=3'') FOR 2-PLY CONT. 2xBLK'G @ 8'-0" O.C. 6x12 DF. NO.1 2x8 @ 16" O.C. MA X . 1 7 / 8 ' ' NOTE: FOR BEAM END CUT SEE DETAIL 3/S1.23 9 W SCALE: NTS. CEILING JOIST PARALLEL TO BEAM DETAIL PROJECT CLIENT 0' 2' 4' 8' 16' SHEET TITLE 1011 W 2ND ST, SANTA ANA, CA 92703 JUAN GARSIA SAZAN INC. 2610 Vista Del Oro, Newport Beach, CA 92660 S1.23 TYPICAL WOOD DETAILS DATE. 12/21/2023 EXP. 06-30-2024           1011 W Second St 5/1/2025 W19 SCALE: NTS.1 PLUMBING DETAIL HVAC CHASE (2) ADJACENT BAYS 3-16d FASTENERS EVERY 16" LOAD BEARING WALL W/ HVAC CHASE RPS28Z (NOTE 1) PSPN58Z (NOTE 3) PSPN516Z (NOTE 2) HVAC CHASE IN EXT. OR LOAD BRG. WALL RPS28 (NOTE 1) CTS218 (NOTE 9) PSPN516Z (NOTE 2) MSTC (NOTE 8) NS2 (NOTE 4) SS1.5 (NOTE 5) WATER OR VENT PIPE TO 2ND FLOOR ELECTRICAL WIRING HSS2- 3-SDS3 (NOTE 7)NS1 (NOTE 4) HSS2-SDS1.5 (NOTE 6) SUPPLY LINES NS1 (NOTE 4) NOTES: 1. RPS28 (16 GAUGE) TO REINFORCE TOP PLATE, AND RPS28Z (16 GAUGE ZMAXTM/) TO REINFORCE SILL PLATE. 2. PSPN516Z (16 GAUGE ZMAXTM/) AT TOP OR BOT PLATES 3. PSPN58Z (16 GAUGE ZMAXTM/) AT TOP OR BOT PLATES AND M1308.2 4. NS - NAIL STOPS TO PROTECT PIPING FROM DRYWALL NAILS OR SCREWS. 5. SS1.5 (16 GAUGE) STUD SHOES REINFORCE AND PROTECT PLUMBING IN 2X. AND M1308.2 AND 2308.5.10 6. HSS2-SDS1.5 (16 GAUGE) HEAVY STUD SHOES TO REINFORCE AND PROTECT SINGLE 2X STUDS WHERE PIPE IS LOCATED. USES (12) SDS 1/4" x 11/2" SCREWS (INCLUDED). 7. HSS2-3-SDS3 (16 GAUGE) HEAVY STUD SHOE FOR TRIPLE 2X STUD. USES (12) SDS 1/4" x 3" SCREWS (INCLUDED). AND M1308.2 AND 2308.5.10 8. MSTC (16 GAUGE) AT TOP PLATE 9. CTS218 (14 GAUGE) TO REINFORCE TOP-PLATE FOR BOTH COMPRESSION AND TENSION FORCES 4.1.4 W20 SCALE: NTS.2 PSPN516Z LC LCCLCL MODEL NO.GA DIMENSIONS BOTTOM PLATE (12) 0.162" x 3 1/2" NAILS TOP PLATE (16) 0.162" x 3 1/2" NAILS (24) 0.162" x 3 1/2" NAILS ALLOWABLE LOAD (lb.) ALLOWABLE LOAD (lb.) ALLOWABLE LOAD (lb.) DF/SP SPF/HF DF/SP SPF/HF DF/SP SPF/HF W L (160) (160) (160) (160) (160) (160) PSPN516Z 16 5"16 5/16"1320 1145 1760 1530 2640 2290 NOTES: 1. TO MEET THE PRESCRIPTIVE IRC REQUIREMENTS 16d BOX NAILS (0.135" DIA x 31/2") MAY BE USED. 2. ALLOWABLE TENSION LOAD IS 0.75 OF TABLE LOADS WHEN INSTALLED W/ 16d BOX NAILS. 16 5/16" 5" SCALE: NTS.3 PSPN516Z NAIL STOPPER (TOP OR BOT PLATE REPAIR PLUS PLUMBING LINE PROTECTOR) W21 SCALE: NTS.4PSPN58Z NAIL STOPPER (PLUMBING LINE PROTECTOR)W22 NOTES: PSPN58Z (16 GAUGE ZMAXTM/) AT TOP OR BOT PLATES PSPN58Z PSPN58Z 8" 5" SCALE: NTS.5 W23 4 1/2" MAX. GAP APPLY CTS218 ON THE BOTH SIDES OF BOTH TOP PLATES AT SHEAR/BRACE WALL LINES, UNO SPECIFICALLY APPROVED BY STRUCTURAL ENGINEER IN WRITING. THE GC SHALL RFI THE FIELD CONDITIONS AS REQUIRED. NS NAIL STOPPER (PLUMBING AND ELECTRICAL LINE PROTECTOR) NOTES: NS - NAIL STOPS TO PROTECT PIPING FROM DRYWALL NAILS OR SCREWS. (3) NS1 <1 1/4" NS2 SUPPLY LINES NS NAIL STOPPER (PLUMBING AND ELECTRICAL LINE PROTECTOR) NS1 (NS2 SIMILAR) W L NS1 NOTES: 1. OPTIONAL NAILS : 8d = 0.131" DIA. x 31/2" LONG. MODEL NO.GA.DIMENSIONS W L NS1 14 11 2" 3" NS2 11 2"6" SCALE: NTS. 8 W25 SS3 SS4.5 SCALE: NTS. 9 FOR NON-LOAD BEARING WALL COMPRESSION-TENSION STRAP (TOP PLATE REPAIR) W26 MODEL NO. GA. STUD SIZE FASTENERS (TOTAL) ALLOWABLE LOADS (lb.) DF/SP LUMBER COMPRESSIONFLOOR (100) ROOF (125) SS1.5 16 2X (12) 0.148" x 11 2"500 500 SS2.5 3X (12) 0.148" x 11 2"730 740 SS3 (2) 2X (12) 0.148" x 3"730 830 SS4.5 (3) 2X (14) 0.148" x 3"840 840 3 1/4" 6" 2 1 / 2 " HSS2 HSS2-3 HSS-SDS STUD SHOE FOR LOAD BEARING WALL(NOTCHED STUD REINF. AND PLUMBING LINE PROTECTOR) MODEL NO. GA.STUD SIZE FASTENERS (TOTAL) ALLOWABLE LOADS (lb.) DF/SP LUMBER COMPRESSION TENSIONFLOOR (100)ROOF (125) HSS2-SDS1.5 16 2X (12) 1 4" x 11 2" SDS 1165 1165 1025 HSS2-2-SDS3 2-2X (12) 1 4" x 3" SDS 1165 1165 1025 HSS2-3-SDS3 3-2X (12) 1 4" x 3" SDS 990 990 960 HSS4-SDS3 4X (12) 1 4" x 3" SDS 1205 1205 1025 NOTES: 1. INSTALLS OVER PIPE UP TO 23/8" OUTSIDE DIAMETER. 2. SDS SCREWS PROVIDED. 3. ROOF LOADS ARE 125% OF FLOOR LOADS UNLESS LIMITED BY OTHER CRITERIA. FLOOR LOADS MAY BE ADJUSTED FOR LOAD DURATIONS ACCORDING TO THE CODE, PROVIDED THEY DO NOT EXCEED ROOF LOADS. 3 1/4" 7 1 / 8 " 2 3 / 4 " CODES: ICC-ES ESR-2608; FLORIDA FL10864 SCALE: NTS. SS/HSS-SDS STUD SHOE FOR LOAD BEARING WALL (CLR. REQUIREMENTS) W27 NOTES: 1. DISTANCE BTWN. CENTER LINE OF SUPPLY LINE AND CENTER LINE OF VENT PIPE MUST BE A MIN. OF 67/8" TO PROVIDE ADEQUATE SPACE FOR THE HSS AND NS2. NS2 SUPPLY LINE VENT PIPE HSS 6 7 / 8 " M I N . 1/2" SCALE: NTS. MSTC (HVAC REPAIRS - AT NON-LOAD BEARING OR SHEAR/BRACE WALL LINES TOP PLATE REPAIR (CONSECUTIVE BAYS)) W28 MODEL NO.GA. DIMENSIONS FASTENERS (TOTAL) ALLOWABLE TENSION LOADS (lb.) DF/SP ALLOWABLE TENSION LOADS (lb.) SPF/HF MSTC5 2 16 W L NAILS (160)(160) 3"521 4" (12) 0.162" x 31 2"1150 995 (16) 0.162" x 31 2"1535 1330 NOTES: 1. MSTC HAS COUNTERSUNK NAIL SLOTS FOR A LOWER PROFILE. 2. USED WHEN THE TOP PLATES ON TWO CONSECUTIVE BAYS HAVE BEEN REMOVED. 3. TO MEET THE PRESCRIPTIVE IRC REQUIREMENTS, 16d BOX (0.135" DIA. x 31/2" LONG) MAY BE USED. ALLOWABLE TENSION LOAD IS 0.88 OF TABLE LOADS WHEN INSTALLED W/ 16d BOX NAILS. 4. NAILS SHOULD BE EQUALLY DISTRIBUTED TO BOTH TOP PLATES. CODES: ICC-ES ESR-2105 W/ LA SUPPLEMENT; HVAC CHASE (2) ADJACENT BAYS MSTC52 BORED HOLES D/3 2 x 6 = 1 13/16" 2 x 8 = 2 7/16" 2 x 10 = 3 1/16" 2 x 12 = 3 3/4" CUTTING AND NOTCHING *40% ALLOWED NON-BRG. PARTITIONS BRG. WALLS AND PARTITIONS ALLOWABLE BORED HOLE MAX. DIA. 40% OF STUD DEPTH THE EDGE OF BORE HOLE SHALL NOT BE CLOSER THAN 5/8'' TO THE EDGE OF THE STUD IN EA. DIRECTION ALLOWABLE CUT OR NOTCH DEPTH IS 25% OF STUD WIDTH NO BORED HOLES LOCATED AT THE SAME SECTION OF THE STUD WHERE CUT OR NOTCH BORDER HOLE 1 7/16" MAX. IN BRG. WALL 2 3/16" MAN IN NON-BRG. WALL 2X STUDS @ 16" O.C. BORED HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF STUD AS A CUT OR NOTCH THE EDGE OF BORE HOLE SHALL NOT BE CLOSER THAN 5/8'' TO THE EDGE OF THE STUD IN EA. DIRECTION ALLOWABLE CUT OR NOTCH DEPTH IN 40% OF WIDTH NON-BRG. PARTITIONS WHERE HOLES ARE OVER 1/3 PLATE WIDTH USE G.I. 1 1/2"X16 GA X12" LONG EA. SIDE W/(5) 8d EA. END ALLOWABLE BORED HOLE 60% OF STUD WIDTH ONLY WHERE EA. BORED STUD IS DOUBLED PROVIDED NOT MORE THAN TWO SUCH SUCCESSIVE STUDS ARE BORED STUD NOTCH 2 x 4 STUD= 1 7/16" MAX. 2 x 6 STUD= 2 3/16" MAX. 2 x 4 STUD= 1 4/16" MAX. 2 x 6 STUD= 2 3/16" MAX. BORED HOLE 5/8" MIN. SIMPSON HSS2-2-SDS3 GALVANIZED W SECTION A WHERE FRAMING MEMBER OCCURS ABV. WITHIN PENETRATED STUD SPACE ADD SUPPORT STUD BELOW CS16 STRAP W/ (12) 8d MIN. EA. END TO PLATE AT EA. PLATE UNOSEE PLANS FOR ADDITIONAL SPLICE REQUIREMENTS 18" MIN.TO PLATE SPLICE 18" MIN.TO PLATE SPLICE SECTION B5/ 8 " M I N . EA . S I D E DRILL NEAT HOLE PER SCHEDULE 16 GAGE AND 1.5' WIDE METAL TIE EA. SIDE OF NOTCH W/ 8-10d NAILS EA. SIDEA B 16 GAGE AND 1.5' WIDE METAL TIE EA. SIDE OF NOTCH W/ 8-10d NAILS EA. SIDE TOP PLATES 2" MIN. FROM TOP&BOT OF JOIST PIPE OF CONDUIT NOTCH GREATER THAN 50% OF THE PLATE WIDTH 7/8" MAX.@BEARING WALL 1 13/16"@NON-BEARING WALL *40% ALLOWED ANY NON-BRG. WALL BORED HOLES *40% ALLOWED BRG. WALL BORED HOLE (2)-2 x 4 STUD BORED HOLE<2" BORED HOLES *25% ALLOWED EXT. WALLS AND BRG. PARTITION STUD NOTCH 2 x 4 STUD= 1 7/16" MAX. 2 x 6 STUD= 2 3/8" MAX. 2 x 4 STUD= 1 7/8" MAX. 2 x 6 STUD= 3 5/16" MAX. BORED HOLE 5/8" MIN. SIMPSON HSS2-3-SDS3 GALVANIZED *60% ALLOWED ANY NON-BRG. WALL OR EA. BORED STUD DOUBLED BORED HOLE NOT PERMITTED IN MORE THAN TWO SUCCESSIVE DOUBLED STUDS *60% ALLOWED BRG. WALL BORED HOLE (3)-2 x 4 STUD BORED HOLE<2 1/2" NOTES: 1. ALL NOTCHES SHOULD BE SEALED WITH A WATER-REPELLENT SEALER, IMMEDIATELY AFTER CUTTING 2. ROUND THE SQUARE CORNER OF THE NOTCH TO A MIN. 1/2" RADIUS. 3. BRG. AND NON-BRG. WALLS: a. NOTCHES AND HOLES ARE ONLY PERMITTED IN OUTER 1/3 OF SPAN LENGTH OF STUD b. BORED HOLES SHALL NOT BE LOCATED IN THE SAME CROSS SECTION OF CUT OR NOTCH IN STUD 4. NON-BRG. WALLS: IF HOLE IS BTWN. 40% AND 60% OF STUD DEPTH, THEN STUD MUST BE DOUBLED AND MORE THAN TWO SUCCESSIVE STUDS ARE DOUBLED AND SO BORED. D (DEPTH) D/3 MAX. CUTTING, NOTCHING AND BORING AT STUD WALL 7 6 10 PSPN516Z (16 GAUGE ZMAXTM) NAIL STOPPER (TOP OR BOT PLATE REPAIR PLUS PLUMBING LINE PROTECTOR)HSS-SDS STUD SHOE FOR LOAD BEARING WALL (NOTCHED STUD REINF. AND PLUMBING LINE PROTECTOR)SS STUD SHOE FOR NON-LOAD BEARING WALL SHOE (NOTCHED STUD REINF. AND PLUMBING LINE PROTECTOR) W24 SCALE: NTS. PROJECT CLIENT 0' 2' 4' 8' 16' SHEET TITLE 1011 W 2ND ST, SANTA ANA, CA 92703 JUAN GARSIA SAZAN INC. 2610 Vista Del Oro, Newport Beach, CA 92660 S1.24 TYPICAL WOOD DETAILS DATE. 12/21/2023 EXP. 06-30-2024           1011 W Second St 5/1/2025 STRUCTURAL PLAN NOTES FOUNDATION PLAN3 FOUNDATION PLAN NOTES CEILING PLAN1 HEADER SCHEDULE UNO ON PLAN MARK HEADER SIZE JACK STUD SIZE KING STUD SIZE HANGER HDR-1 4x12 DF. NO.1 -4x6 HUC412 HDR-2 4x6 2x4 2x4 - HDR-3 4x8 2-2x4 2x4 - POST SCHEDULE UNO ON PLAN MARK POST SIZE C44 4x4 C46 4x6 JOIST & HANGER SCHEDULE UNO ON PLAN MARK JOIST SIZE HANGER RR-1 2x8 @16" O.C.- CJ-1 2x8 @16" O.C. W/BLK'G@8'-0"- STUD WALL SCHEDULE UNO ON PLAN MAX. HEIGHT INT. WALL EXT. WALL 8'-00"2x4 @16" O.C.2x4 @16" O.C. STRUCTURAL & FOUNDATION PLAN SCHEDULE ROOF PLAN2 SCALE: 1/4"=1'-0"SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" RR-1 RR-1 C44 C44 C44 W/B C 4 0 SW1 (18'-2") SW 1 (2 1 ' - 1 " ) 4x 1 0 4x 1 0 6x12 No.1 SW4 (3'-1") 1 2 A B HD R - 2 1 2 A B 1 2 A B HDU 5C46 12" 12 " 12 " C44 W/B C 4 MST37 MSTC40 MST37 C44 W/B C 4 SW1 (18'-2") SW 1 (2 1 ' - 1 " ) SW 1 (1 7 ' - 8 " ) HDU 5 HDU 5 C46 C44 CJ-1 HDR-1 C46 W/B C 4 60 12" HUC412 SEE HANGER SCHED. SW4 (3'-1") C.A . W/B C 4 0 C46 W/B C 4 6HD R - 3 (2)SIMPSON MSTA49 AT TOP PLATE HDU 5 C46 HDU 5C46 1 S1.01 C46 8 S1.23 7 S1.23 SW1 (18'-2") SW 1 (2 1 ' - 1 " ) SW 1 (1 7 ' - 8 " ) 8 S1.23 7 S1.23 6 S1.23 MSTC52 SEE 3/S1.21 TYP. MSTC52 5" SOG ON ENGINEERED FIELD MATERIAL BASED ON ARCH. DWGS. W/ #4@18" EA. WAY. SEE SOG REQUIREMENT NOTES FOR CAPILLARY BREAK REQUIREMENTS. TYP. 4 S1.01 TYP. TYP. TYP. 9 S1.23 TYP. TYP. C46 C46 C46 S1.23 5 SW 1 (1 7 ' - 8 " ) TYP. MST48 HDU 5 MST48 INDICATES TENSION STRAP INDICATES SHEARWALL TYPE FOR SHEARWALL SCHEDULE SEE 1/S1.21 INDICATES MINIMUM LENGTH OF SHEARWALL SWXX (#'-#") INDICATES WOOD BEAM INDICATES WOOD HEADER SEE 2/S1.22 FOR MORE INFORMATION RB INDICATES HOLDOWN TYPE X HDR INDICATES WOOD POST MARK, SEE POST SCHEDULE C# HDU X SYMBOL DESCRIPTIONS INDICATES JOIST INDICATES HANGER J# # S#.##INDICATES SECTION INDICATES SHEET NUMBER INDICATES DETAIL NUMBER ON THE SHEET S#.## # INDICATES CALLOUT #INDICATES REVISION ON DRAWINGS INDICATES VIEW# S#.##INDICATES LOAD BEARING WALL BW INDICATES WOOD HEADER SEE HEADER SCHEDULE TABLE ON PLAN HDR-# 1. SOIL SUBGRADE REQUIREMENTS, ELEVATION AND SLOPING OF FOUNDATIONS AND SOG, AND CONSTRUCTION REQUIREMENTS ARE NOT PART OF THIS SCOPE OF WORK OR THE LIABILITY OF THE STRUCTURAL ENGINEER. 2. IF GEOTECHNICAL REPORT OR CIVIL DWGS. ARE AVAILABLE, CONTRACTOR SHALL REVIEW AND FOLLOW THE GEOTECHNICAL REPORT AND CIVIL DWG. FOR THE CONSTRUCTION OF SOIL SUBGRADE AND SOG. 3. IN THE ABSENCE OF GEOTECHNICAL REPORT, OR CIVIL REPORT AND DWGS. THE DETAILS SHOWN ON THESE DWGS. MAY BE CONSIDERED BY THE OWNER/GC ON THEIR OWN RISK. STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY DAMAGES THAT MAY OCCUR DUE TO USING THESE RECOMMENDATIONS.THESE ARE GENERAL RECOMMENDATIONS FOR THE CONSTRUCTION OF SOIL SUBGRADE. THESE DETAILS DO NOT CONSIDER THE ACTUAL FIELD CONDITIONS. 3.1. SOG AND FOUNDATIONS SHALL BE CONTINUOUSLY SUPPORTED ON UNDISTURBED OR ENGINEERED FILL SOIL. 3.2. THE AREA WITHIN THE SOG AND FOUNDATION WALLS SHALL HAVE ALL VEGETATION, TOP SOIL AND FOREIGN MATERIAL REMOVED. 3.3. FILL MATERIAL SHALL BE FREE OF VEGETATION AND FOREIGN MATERIAL. THE FILL SHALL BE COMPACTED TO ENSURE UNIFORM SUPPORT OF THE SOG, FOUNDATION, AND THE FILL DEPTHS SHALL NOT EXCEED 24 IN FOR CLEAN SAND OR GRAVEL AND 8 IN FOR EARTH. 3.4. AT SOG AREA, REINFORCING STEEL SHALL BE SUPPORTED TO REMAIN IN PLACE FROM THE CENTER TO MIDDLE FOURTH OF THE SLAB FOR THE DURATION OF THE CONC. PLACEMENT. 3.5. SCARIFY TOP 12" OR RECOMPAC 4' OVEREXCAVATION PRIOR TO TRENCHING FOR THE UTILITY AND/OR FOUNDATION. 90% COMPACTION REPOR IS REQD. AT THE TIME OF FOUNDATION INSPCTION. DAMP PROOFING, BASE COURSE AND PRE-SATURATION ARE REQUIRED THE SPECIAL INSPECTOR SHALL VERIFY THAT THE IN-PLACE DRY DENSITY OF THE COMPACTED FILL IS NOT LESS THAN 90 PERCENT OF THE MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE CONTENT DETERMINED IN ACCORDANCE W/ ASTM D1557. 3.6. AT SOG AREA, A 4 IN THICK SUB-BASE COURSE CONSISTING OF ½” OR LARGER CLEAN AGGR EGATE. 3.7. A 10-MIL VAPOR RETARDER/MOISTURE BARRIER CONFORMING TO THE REQUIREMENTS OF ASTM E1745 GLASS A W/ JOINTS LAPPED NOT LESS THAN 6 IN SHALL BE PLACED BTWN. THE CONC. FLOOR SLAB AND THE BASE COURSE OR THE PREPARED SUBGRADE WHERE NO BASE COURSE EXISTS. UNLESS REQUIRED BY BUILDING OFFICIALS THE MOISTURE BARRIER IS NOT MANDATORY FOR DRIVEWAYS, WALKS, PATIOS AND OTHER FLAT WORK NOT LIKELY TO BE ENCLOSED AND HEATED AT A LATER DATE. 4. PROVIDE CONTROL JOINTS AT CL. OF CONC. OR STEEL COLUMNS IF NO CONSTRUCTION JOINTS OCCUR. 5. CONTRACTOR TO SUBMIT A JOINTING PLAN TO ARCHITECT FOR REVIEW. 6. THE TOP SURFACE OF FOUNDATIONS SHALL BE LEVEL ,UNO ON ARCH. DWG. 7. THE BOTTOM SURFACE OF FOUNDATION AND SOG SHALL NOT HAVE A SLOPE EXCEEDING ONE UNIT VER. IN 12 UNITS HOR. 8. UNO ON PLANS OR TYPICAL DETAILS, NO HOR. CONSTRUCTION SHALL BE PERMITTED IN THE FOUNDATIONS. ALL OTHER CONSTRUCTION JOINTS SHALL BE SUBMITTED TO SEOR AND ARCH FOR REVIEW. SOG REQUIREMENT NOTES C46HDU 5 C46HDU 5 CJ-1 S1.21 5 TYP. 1 S1.01 2 TYP. 1 1. T HESE D R AWING AR E BAS ED ON THE B E S T AV A ILA B L E S OU R CES AND DO NO T A DD RE S S T HE F I ELD CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND ALL EXISTING STRUCTURAL E L E M E N T S S P E C I F I E D A S V E R I F I E D I N F I E L D (V .I .F .) P R I O R T O C O M M E N C I N G T H E W O R K . A N Y DISCREPANCIES BETWEEN THESE DRAWINGS AND FIELD CONDITIONS SHALL BE REPORTED TO THE AEOR AND SEOR . NO WOR K S HALL BE P E RF ORMED IN T HE A FFECTED AR EAS UN TIL THE DI SCREP AN CIES A RE RESOLVED. 2. NO CUTTING, DRILLING, DEMOLITION OR DESTRUCTIVE WORK ON CONCRETE OR WOOD ELEMENTS SHALL BE PERMITTED UNLESS ALL REINFORCING STEEL INCLUDING PT TENDONS, BEARING WALLS, SHEAR WALLS, BEAMS,AND DIRECTIONS OF JOISTS AND RAFTERS THAT WILL BE AFFECTED ARE POSITIVELY IDENTIFIED. 3 . CO N TR AC T O R IS S OLE L Y R ESPO N SI B L E FO R P R O T E C T IO N O F A L L S T R U C T U R AL, N ONS T R UCTUR A L, ARCHITECTURAL, FINISHING, ELECTRICAL AND MECHANICAL COMPONENTS WHICH ARE NOT DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION. ANY DAMAGES CAUSED BY THE CONTRACTOR OR SUBCONTRACTORS SHALL BE REPAIRED BY THE CONTRACTOR AT NO COSTS TO THE ENGINEERS OR OWNER. 4. STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS INTO THE SHOP DRAWINGS AND FIELD WORK. 5. ALL ELEVATIONS, SLOPES, DRAINAGE, DIMENSIONS OF OPENINGS, PENETRATIONS, DEPRESSIONS, AND LAYOUT AND GEOMETRY OF NONSTRUCTURAL ELEMENT SUCH AS BUT NOT LIMITED TO PARTITION, WINDOWS, PLUMBING, ARE NOT INCLUDED IN THE STRUCTURAL ENGINEERING SCOPE OF WORK AND SHALL NOT BE THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER. REFER TO THE DRAWINGS FROM OTHER PROFESSIONS FOR THE INFORMATION MENTIONED ABOVE. 6. FOR CONSTRUCTION NOTES AND TYPICAL SYMBOLS DESCRIPTIONS, SEE S0 SERIES SHEETS. 7. FOR TYPICAL DETAILS, SEE S1 SERIES SHEETS. DETAILS AND SCHEDULES INDICATED AS 'TYPICAL' MAY NOT BE SPECIFICALLY REFERENCED ON DRAWINGS. DETERMINE WHERE EACH TYPICAL DETAIL OR SCHEDULE APPLIES BEFORE PROCEEDING WITH WORK. 8. SEE ARCH./CIVIL DWGS. FOR CONCRETE SLAB ELEVATIONS, DEPRESSIONS, SLOPES, OPENINGS, CURBS, DRAINS, TRENCHES, SLAB EDGE LOCATIONS, ETC., AND FOR WALL OVERALL DIMENSIONS, LOCATIONS OF OPENINGS, ETC., NOT INDICATED ON STRUCTURAL DRWGS. 9. HOLD-DOWNS& ANCHORS HARDWARE MUST BE SECURED IN PLACE PRIOR TO CALLING FOR FOUNDATION INSPECTION. WET SETTING ANCHORS IS PROHIBITED. 10. APPROVED PLATE WASHERS SHALL BE USED FOR HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING. HOLD-DOWNS SHALL BE FINGER TIGHT AND 1/2 WRENCH TURN JUST PRIOR TO COVERING WALL FRAMING. 11. STANDING WATER SHALL BE REMOVED FROM THE FOUNDATION EXCAVATIONS PRIOR TO THE CONCRETE PLACING. 12. UNO IN ARCH./CIVIL DWGS. SURFACE OUTSIDE THE HOUSE NEEDS TO HAVE 5% SLOPE (UNPAVED SURFACE) & 2% SLOPE (PAVED SURFACE) AWAY FROM THE STRUCTURE. 13. FOUNDATION EXCAVATIONS SHALL BE INSPECTED AND APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT OF STEEL, IF HIRED. A MEMO SHALL BE AVAILABLE TO THE CITY INSPECTOR AT TIME OF FOUNDATION INSPECTION. 14. ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL PLATE SHALL BE OF HOT-DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. 15. MINIMUM EDGE DISTANCE FOR ANCHOR BOLTS SHALL BE 1-3/4". ALL ANCHOR BOLTS SHALL INCLUDE A MINIMUM 0.229"X3"X3" STEEL PLATE WASHER. THE HOLE IN THE PLATE WASHER SHALL BE PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3/16" LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT TO EXCEED 1-3/4", PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. THE PLATE WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE BOTTOM PLATE ON THE SIDE(S) FOR SHEATHING WITH SHEAR DESIGN VALUES EXCEEDING 400PLF. 16. THE FOUNDATION PLAN SHOWS THE GENERAL LAYOUT OF THE FOUNDATION. FOR LOCALIZED SIZE CHANGES AT THE HOLD-DOWNS, REFER TO TYPICAL DETAILS. AT ALL HOLD-DOWN LOCATIONS, FOUNDATION SHALL BE CONSTRUCTED WITH THE DIMENSIONS SPECIFIED IN TABLE FOR HOLD-DOWN ANCHOR SCHEDULE SEE SHEET S1.01. 17. ALL WOOD MEMBERS IN CONTACT WITH MASONRY AND CONCRETE SHALL BE PRESSURE-TREATED AND CONFORM TO THE REQUIREMENT OF "AWPA U1" FOR CATEGORY UC4A OR BETTER. 18. WOOD AND WOOD BASED MATERIALS USED RAISED FLOOR SYSTEMS INCLUDING JOISTS AND BEAMS SHALL CONFORM TO THE REQUIREMENTS OF "AWPA U1" FOR CATEGORY UC3B OR HIGHER. 19. NO HORIZONTAL COLD JOINTS OTHER THAN THE LOCATIONS SHOWN ON THESE DRAWINGSSHALL BE PERMITTED IN FOUNDATION CONSTRUCTION. ALL CONSTRUCTION JOINTS SHALL BESUBMITTED TO SEOR FOR REVIEW. 20. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLKG SHALL BE PROVIDED AT PLYWD JOINTS FOR ALL WALLS. 21. SPECIAL SOIL CONDITIONS AND PROPERTIES SUCH AS LIQUEFACTION ZONES; ADJACENT TO OR WITHIN AREAS PRONE TO LANDSLIDE, SLOPED LOTS GREATER THAN 1 UNIT VERTICAL UNITS HORIZONTAL ARE NOT INCLUDED IN THIS SCOPE OF WORKS AND NOT CONSIDERED FOR FOUNDATION DESIGN. OWNER SHALL HIRE A SOIL ENGINEER TO VERIFY THESE CONDITIONS AND THEIR EFFECTS ON STRUCTURAL ELEMENTS. 22. CONSTRUCTION BELOW THE RAISED FLOOR AND AT CRAWL SPACE INCLUDING LUMBERS AND TIMBERS SHALL BE GRADE 1 OR BETTER , JOISTS & BEAM THAT ARE AT LEAST 18" ABOVE GROUND SHALL BE CATEGORY 3B OR HIGHER AND POSTS, SILL PLATES AND BEAMS AND JOISTS LESS THAN 18" ABOVE THE GROUND SHALL BE CATEGORY 4A OR HIGHER AS SPECIFIED BY AWPA STANDARD U1. 23. ALL CRIPPLE WALLS SHALL BE BRACED. 24. ALL TOP AND BOTTOM CONTINUEL/ LONGITUDINAL BARS IN STRIP FOUNDATIONS SHALL HAVE STANDARD HOOKS AT THE ENDS. 25. ALL TOP AND BOTTOM DISCONTINUED/ LOCAL BARS ( IN BOTH DIRECTIONS ) AT THE PAD/ ISOLATED FOUNDATIONS SHALL HAVE STANDARD HOOKS AT THE ENDS. 26. ALL SOG BARS SHALL HAVE STANDARD HOOKS AT THE ENDS. 27. FOR DRAINAGE LAYOUT AND REQUIREMENTS, SEE ARCHITECTURAL/CIVIL DRAWINGS. DRAINAGE IS NOT INCLUDED IN STRUCTURAL ENGINEER'S SCOPE OF WORK. 28. WHERE THE STEEL COLUMNS ARE EXPOSED TO WEATHER, BASE PLATES AND COLUMNS UP TO 12" ABOVE THE CONCRETE SLAB SHALL BE COATED WITH MIN. 2 COATS OF MACROPOXY 646. 29. ALL PERMANENT STEELS IN CONTACT WITH WEATHER SHALL BE PROTECTED FOR CORROSION. 30.ALL HANGERS ,COLUMN CAPS ,AND COLUMN BASES ARE MINIMUM REQUIREMENTS ,PRIOR TO ORDER ALL OF THEM SHALL BE CHECKED BY THE CONTRACTOR / FRAMER ANY DISCREPANCY SHALL BE REPORTED TO SEOR. 31. FOR ALL BASEPLATES AND STEELS THAT ARE OUTSIDE OR UNDER GROUND, APPLY MIN. 2 COATS OF MACROPOXY 646 WITH MINIMUM 8 MILS THICKNESS. HDU 2C44 HDU 2 C44 C.A . W/B C 4 0 HUC412 SEE HANGER SCHED. S1.23 4 C44 W/B C 4 HDU 2C44 HDU 2 C44 HDU 2 C44 HDU 2 C44 C44 HANGER SCHEDULE UNO ON PLAN MODEL FACE FASTENERS MEMBER FASTENERS HUC412 (12) 0.162 x 3 1 2"(10) 0.148 x 3 C46 SW4 (3'-1") SW4 (3'-1") C46 SW4 (3'-1") SW4 (3'-1") USE (4)SDS25800 SCREW FOR HDR TO C46 POST AT EACH ENDS. SEE 1/S1.22. 1 . THE S E DR A WING AR E BA S E D O N TH E BES T A VA IL AB LE SO UR C E S AND DO N OT A DDR ESS THE FIELD CONDITIONS. THE CONTRACTOR SHALL VER IFY ALL FIELD CONDITIONS AND ALL EXISTING STRUCTURAL E L E M E N T S S P E C I F I E D A S V E R I F I E D I N F I E L D (V .I .F .) P R I O R T O C O M M E N C I N G T H E W O R K . A N Y DISCREPANCIES BETWEEN THESE DRAWINGS AND FIELD CONDITIONS SHALL BE REPORTED TO THE AEOR A ND SE OR. NO WOR K S HALL BE PER FOR MED I N T HE AFFECTED AREAS UNTIL THE DI SCR EPA NCIES AR E RESOLVED. 2. NO CUTTING, DRILLING, DEMOLITION OR DESTRUCTIVE WORK ON CONCRETE OR WOOD ELEMENTS SHALL BE PERMITTED UNLESS ALL REINFORCING STEEL INCLUDING PT TENDONS, BEARING WALLS, SHEAR WALLS, BEAMS,AND DIRECTIONS OF JOISTS AND RAFTERS THAT WILL BE AFFECTED ARE POSITIVELY IDENTIFIED. 3. C ONT R ACTO R IS S OLELY R E S P ONS I BLE FO R P R OT E C T I O N OF ALL STR UC T U R AL, NO N STR UC T U R AL, ARCHITECTURAL, FINISHING, ELECTRICAL AND MECHANICAL COMPONENTS WHICH ARE NOT DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION. ANY DAMAGES CAUSED BY THE CONTRACTOR OR SUBCONTRACTORS SHALL BE REPAIRED BY THE CONTRACTOR AT NO COSTS TO THE ENGINEERS OR OWNER. 4. STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS INTO THE SHOP DRAWINGS AND FIELD WORK. 5. ALL ELEVATIONS, SLOPES, DRAINAGE, DIMENSIONS OF OPENINGS, PENETRATIONS, DEPRESSIONS, AND LAYOUT AND GEOMETRY OF NONSTRUCTURAL ELEMENT SUCH AS BUT NOT LIMITED TO PARTITION, WINDOWS, PLUMBING, ARE NOT INCLUDED IN THE STRUCTURAL ENGINEERING SCOPE OF WORK AND SHALL NOT BE THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER. REFER TO THE DRAWINGS FROM OTHER PROFESSIONS FOR THE INFORMATION MENTIONED ABOVE. 6. REVIEW ALL NOTES PROVIDED IN FRAMING LUMBER AND ENGINEERED WOOD PRODUCT SECTION FOR GENERAL REQUIREMENTS AND CONFORMANCE OF STRUCTURAL WOOD. 7. FOR TYPICAL DETAILS SEE S1 SERIES SHEETS. 8. ROOF SHEATHING OVER ROOF RAFTER/JOISTS NOT SPACED MORE THAN 16" OC. SHALL BE 15/32" OR 1/2" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 32/16 WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQURE EDGE (OR TONGUE-AND-GROOVE). NAILS SHALL BE 8d WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD FOR 1-3/8 IN. NAIL SPACING AT INTERMEDIATE FRAMING (FIELD NAILING) SHALL NOT BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. 9. ROOF SHEATHING OVER RAFTERS/JOISTS OR TRUSSES SPACED AT 24" OC. SHALL BE 19/32" OR 5/8" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 40/20 WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQURE EDGE (OR TONGUE-AND-GROOVE). 10. FLOOR SHEATHING SHALL BE 23/32" OR 3/4" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 48/24 WITH EXTERIOR GLUE, (EXPOSURE 1 OR EXTERIOR), SQURE EDGE (OR TONGUE-AND-GROOVE ).NAILS SHALL BE 10d WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD FOR 1-3/8 IN. NAIL SPACING AT INTERMEDIATE FRAMING (FIELD NAILING) SHALL NOT BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN, U.N.O. ON PLANS. 11. BALCONY FRAMES AND SHEATHING SHALL BE EXTRIOR GRADE. BALCONY SHEATHING SHALL BE 3/4" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 48/24, EXTERIOR, SQURE EDGE (OR TONGUE-AND-GROOVE ). 12. ROOF, FLOOR AND BALCONY PANEL EDGES SHALL HAVE APPROVED TONGUE-AND-GROOVE JOINTS OR SHALL BE SUPPORTED WITH BLOCKING. 1-1/2" THICK PANELS WITH 1/4" MINIMUM THICKNESS UNDERLAYMENT OR 1-1/2" OF APPROVED LIGHTWEIGHT CONCRETE PLACED OVER THE SUB-FLOOR, DO NOT REQUIRE BLOCKING AT THE EDGES. 13. ALL EXTERIOR WALLS SHALL BE SHEATHED ON THE OUTSIDE OF THE WALL, INCLUDING GABLES, AND THE CONNECTION OF THE SHEATHING TO FRAMING. SHEATHING SHALL BE 15/32" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, STRUCTURAL-I, WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQURE EDGE. 14. ALL SHEATHING SHALL BE LAID CONTINUOUS OVER TWO OR MORE SUPPORTS WITH FACE GRAIN PERPENDICULAR TO SUPPORTS (UNLESS SHOWN OTHERWISE). STAGGER ALL SHEATHING PANELS A MINIMUM OF ONE JOIST BAY. 15. UNO PER SHEAR WALL SCHEDULE, OR SHOWN ON THE THESE DRAWINGS ALL SHEATHING SHALL BE NAILED TO THE FARMING AS FOLLOWS: 15.1. FASTENERS SHALL BE 10d COMMON NAILS 15.2. SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. 15.3. SPACING AT INTERMEDIATE FRAMING (FIELD NAILING, F.N.) SHALL NOT BE MORE THAN 12 IN. 15.4. FASTENER PENETRATION IN FRAMING WOOD SHALL NOT BE LESS THAN 1-1/2 IN. 15.5. BLOCK ALL EDGES 15.6. USE 3X LUMBER AT THE CONNECTION OF TWO PANEL EDGES, UNO ON PLANS OR DETAILS. 16. ROOF PLYWOOD SHEATHING SHALL BE CONTINUED BENEATH THE CALIFORNIA FRAMING, IF APPLICABLE. 17. ALL WOOD STRUCTURAL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED AT ALL PANEL EDGES. 18. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLK'G SHALL BE PROVIDED AT PLYWOOD JOINTS FOR ALL WALLS. 19. ROOF AND FLOOR DIAPHRAGM NAILING SHALL BE INSPECTED BEFORE COVERING. 20. NO PENETRATIONS ARE ALLOWED THROUGH SHEARWALL UNLESS SPECIFICALLY DETAILED ON THESE NOTES. 21. ALL POST TO BEAM AND BEAM TO POST SHALL BE CONNECT W/ CCQ/ECCQ UNO ON PLAN. 22. ALL BEAMS ARE FLUSH (NOT DROPPED) UNO ON PLAN. 23. EXTERIOR CONSTRUCTION INCLUDING BALCONY, PATIO LUMBERS AND TIMBERS SHALL BE PRESSURE-TREATED AND GRADE 1 OR BETTER AND CLASSIFIED FOR EXTERIOR CONSTRUCTION, DECK BOARDS, JOISTS & BEAM ABOVE GROUND SHALL BE CATEGORY 3B OR HIGHER AND POSTS SHALL BE CATEGORY 4A OR HIGHER AS SPECIFIED BY AWPA STANDARD U1. 24. PATIO COVER SHEATHING OVER JOISTS NOT SPACED MORE THAN 24" OC. SHALL BE 19/32" APA RATED WITH SPAN RATING 32/16 EXTERIOR EXPOSURE. NAILS SHALL BE 8D WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD OF 1-3/8 INCHES. NAIL SPACING AT INTERMEDIATE FRAMING FIELD NAILING) SHALL BE MORE THAN 12 IN. NAIL SPACINGAT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. 25. IF EXISTING CONSTRUCTION IS INCLUDED IN THIS SCOPE OF WORK, ABOVE MENTIONED SHEATHING REQUIREMENT SHALL BE VERIFIED FOR EXISTING ROOF, FLOOR, AND WALLS THAT ARE INCLUDED WITH THIS SCOPE OF WORK.SEE GYPSUM BOARD AND EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER (STUCCO) FOR THE INSTALLATION OF STUCCO AND DRYWALLS. 26. SEE TYPICAL WALL DETAILS FOR THE ADDITIONAL INFORMATION ON HEADERS, KING STUDS AND JACK STUDS. 27. SEE GYPSUM BOARD AND EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER (STUCCO) NOTES FOR THE INSTALLATION OF STUCCO AND DRYWALLS. 28. SOLAR PANEL DESIGN AND CONNECTIONS TO THE SUPPORTING ELEMENTS ARE NOT INCLUDED IN THE STRUCTURAL SCOPE OF WORK. A MAXIMUM DEAD-LOAD OF 3 PSF WAS CONSIDERED IN THE STRUCTURAL DESIGN. THE GC SHALL INFORM STRUCTURAL ENGINEER IN WRITING, IF A HEAVIER SOLAR SYSTEM IS USED IN CONSTRUCTION. 29.ALL HANGERS ,COLUMN CAPS ,AND COLUMN BASES ARE MINIMUM REQUIREMENTS ,PRIOR TO ORDER ALL OF THEM SHALL BE CHECKED BY THE CONTRACTOR / FRAMER ANY DISCREPANCY SHALL BE REPORTED TO SEOR. 30. ALL STEEL CONNECTORS INCLUDING BOLTS, SCREWS AND NAILS USED IN EXTERIOR STRUCTURE OR EXPOSED TO WEATHER SHALL BE STAINLESS STEEL OR HOT-DIP GALVANIZED. FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT TREATED WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. 31. PROVIDE ONE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 8 FT BUT LESS THAN 16 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED MID-SPAN OF THE JOIST. 32. PROVIDE TWO INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 16 FT BUT LESS THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED 1/3 OF THE SPAN FROM EACH END. 33. PROVIDE THREE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED NOT MORE THAN 8 FT ALONG THE SPAN FROM EACH OTHER. 1011 W 2ND ST, SANTA ANA, CA 92703 PROJECT CLIENT 0'2'4'8'16' SHEET TITLE SAZAN INC. 2610 Vista Del Oro, Newport Beach, CA 92660 JUAN GARSIA S2.01 CLG, ROOF & FOUNDATION PLAN 11/19/2024 EXP. 06-30-2026 1011 W Second St 5/1/2025 GN-1 GARCIA RESIDENCE SHEET PROPERTY OWNER: JUAN GARCIA (949) 627-2074 REV DATE DESCRIPTION 10/16/23A THERE SHALL BE NO CHANGES OR DEVIATION ON THESE PLANS WITHOUT TH E CONSENT OF PLAN AND PERMIT IN C. NOTES AND DETAILS ON THE DRAW INGS SHALL TAKE PRECEDENCE OVER GENERAL NOTE S AND TYPICAL DETAILS. WHERE NO DETAILS SH OWN OR NOTED ON THE DRAWINGS, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK.CONTRACTOR SHALL VERI FY ALL PLANS, EXISTING DIMENSIO NS AND FIELD CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY TO PLAN AND PERMIT INC ANY DISCREPANCIES IN WR ITING PRIOR TO THE COMMENCEMENT OF ANY WOR K OR BE RESPONSIBLE FOR SAME. TH E S E D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F P L A N A N D P E R M I T I N C A N D S H A L L N O T B E U S E D I N C O N N E CT I O N W I T H A N Y O T H E R W O R K E X C E P T B Y A G R E E M E N T W I T H P L A N A N D P E R M I T I N C . B Y U S I N G T H E S E P L A N S , T H E U S E R A G R E E S T O R E L E A S E P L A N A ND P E R M I T I N C F R O M A N Y A N D A L L C L A I M S , L I A B I L I T I E S , S U I T S , A N D D E M A N D S O N A C C O U N T O F A N Y I N J U R Y , D A M A G E O R L O S S O R P E R S O N S O R P RO P E R T Y , I N C L U D I N G I N J U R Y O R D E A T H , O R E C O N O M I C L O S S E S , A R I S I N G O U T O F T H E U S E O F T H E S E P L A N S . SKETCH FOR REVIEW 11/17/23 B 90PD FOR APPROVALC 01/02/240 100PD FOR SUBMITTAL 10/31/23 90PD FOR REVIEW PROPERTY ADDRESS: 1011 W 2ND ST, SANTA ANA, CA 92703 PLAN AND PERMIT INC. ARCHITECTURAL DESIGN SERVICES 9891 IRVINE CENTER DR #200 IRVINE, CA 92618 (714)-715-0923 biz@planandpermit.com LOCATION QR CODE: STATE OF CAL IFORNIAEXP. DATE L I C E NS E D A R CHI T E C T C - 34643 06/30/2025 SIGNATURE PAUL SAN GEMINO GENERAL NOTES CHAPTER 4 RESIDENTIAL MANDATORY MEASURES DIVISION 4.1 PLANNING AND DESIGN DIVISION 4.3 WATER EFFICIENCY AND CONSERVATION 4.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN. Submit a construction waste management plan in conformance with Items 1 through 5. The construction waste management plan shall be updated as necessary and shall be available during construction for examination by the enforcing agency. 1. Identify the construction and demolition waste materials to be diverted from disposal by recycling, reuse on the project or salvage for future use or sale. 2. Specify if construction and demolition waste materials will be sorted on-site (source separated) or bulk mixed (single stream). 3. Identify diversion facilities where the construction and demolition waste material collected will be taken. 4. Identify construction methods employed to reduce the amount of construction and demolition waste generated. 5. Specify that the amount of construction and demolition waste materials diverted shall be calculated by weight or volume, but not by both. 4.408.3 WASTE MANAGEMENT COMPANY. Utilize a waste management company, approved by the enforcing agency, which can provide verifiable documentation that the percentage of construction and demolition waste material diverted from the landfill complies with Section 4.408.1. Note: The owner or contractor may make the determination if the construction and demolition waste materials will be diverted by a waste management company. 4.408.4 WASTE STREAM REDUCTION ALTERNATIVE [LR]. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 3.4 lbs./sq.ft. of the building area shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.4.1 WASTE STREAM REDUCTION ALTERNATIVE. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 2 pounds per square foot of the building area, shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.5 DOCUMENTATION. Documentation shall be provided to the enforcing agency which demonstrates compliance with Section 4.408.2, items 1 through 5, Section 4.408.3 or Section 4.408.4.. Notes: 1. Sample forms found in "A Guide to the California Green Building Standards Code (Residential)" located at www.hcd.ca.gov/CALGreen.html may be used to assist in documenting compliance with this section. 2. Mixed construction and demolition debris (C & D) processors can be located at the California Department of Resources Recycling and Recovery (CalRecycle). 4.410 BUILDING MAINTENANCE AND OPERATION 4.410.1 OPERATION AND MAINTENANCE MANUAL. At the time of final inspection, a manual, compact disc, web-based reference or other media acceptable to the enforcing agency which includes all of the following shall be placed in the building: 1. Directions to the owner or occupant that the manual shall remain with the building throughout the life cycle of the structure. 2. Operation and maintenance instructions for the following: a. Equipment and appliances, including water-saving devices and systems, HVAC systems, photovoltaic systems, electric vehicle chargers, water-heating systems and other major appliances and equipment. b. Roof and yard drainage, including gutters and downspouts. c. Space conditioning systems, including condensers and air filters. d. Landscape irrigation systems. e. Water reuse systems. 3. Information from local utility, water and waste recovery providers on methods to further reduce resource consumption, including recycle programs and locations. 4. Public transportation and/or carpool options available in the area. 5. Educational material on the positive impacts of an interior relative humidity between 30-60 percent and what methods an occupant may use to maintain the relative humidity level in that range. 6. Information about water-conserving landscape and irrigation design and controllers which conserve water. 7. Instructions for maintaining gutters and downspouts and the importance of diverting water at least 5 feet away from the foundation. 8. Information on required routine maintenance measures, including, but not limited to, caulking, painting, grading around the building, etc. 9. Information about state solar energy and incentive programs available. 10. A copy of all special inspections verifications required by the enforcing agency or this code. 11. Information from the Department of Forestry and Fire Protection on maintenance of defensible space around residential structures. 12. Information and/or drawings identifying the location of grab bar reinforcements. 4.410.2 RECYCLING BY OCCUPANTS. Where 5 or more multifamily dwelling units are constructed on a building site, provide readily accessible area(s) that serves all buildings on the site and are identified for the depositing, storage and collection of non-hazardous materials for recycling, including (at a minimum) paper, corrugated cardboard, glass, plastics, organic waster, and metals, or meet a lawfully enacted local recycling ordinance, if more restrictive. Exception: Rural jurisdictions that meet and apply for the exemption in Public Resources Code Section 42649.82 (a)(2)(A) et seq. are note required to comply with the organic waste portion of this section. DIVISION 4.5 ENVIRONMENTAL QUALITY 4.303 INDOOR WATER USE 4.303.1 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the sections 4.303.1.1, 4.303.1.2, 4.303.1.3, and 4.303.4.4. Note: All noncompliant plumbing fixtures in any residential real property shall be replaced with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy, or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 4.303.1.1 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Tank-type Toilets. Note: The effective flush volume of dual flush toilets is defined as the composite, average flush volume of two reduced flushes and one full flush. 4.303.1.2 Urinals. The effective flush volume of wall mounted urinals shall not exceed 0.125 gallons per flush. The effective flush volume of all other urinals shall not exceed 0.5 gallons per flush. 4.303.1.3 Showerheads. 4.303.1.3.1 Single Showerhead. Showerheads shall have a maximum flow rate of not more than 1.8 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Showerheads. 4.303.1.3.2 Multiple showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all the showerheads and/or other shower outlets controlled by a single valve shall not exceed 1.8 gallons per minute at 80 psi, or the shower shall be designed to only allow one shower outlet to be in operation at a time. Note: A hand-held shower shall be considered a showerhead. 4.303.1.4 Faucets. 4.303.1.4.1 Residential Lavatory Faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.2 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. 4.303.1.4.2 Lavatory Faucets in Common and Public Use Areas. The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. 4.303.1.4.3 Metering Faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.2 gallons per cycle. 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. Note: Where complying faucets are unavailable, aerators or other means may be used to achieve reduction. 4.303.1.4.5 Pre-rinse spray valves. When installed, shall meet the requirements in the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Sections 1605.1 (h)(4) Table H-2, Section 1605.3 (h)(4)(A), and Section 1607 (d)(7) and shall be equipped with an integral automatic shutoff. FOR REFERENCE ONLY: The following table and code section have been reprinted from the California Code of Regulations, Title 20 (Appliance Efficiency Regulations),Section 1605.1 (h)(4) and Section 1605.3 (h)(4)(A). Title 20 Section 1605.3 (h)(4)(A): Commercial prerinse spray values manufactured on or after January 1, 2006, shall have a minimum spray force of not less than 4.0 ounces-force (ozf)[113 grams-force(gf)] 4.303.2 Submeters for multifamily buildings and dwelling units in mixed-used residential/commercial buildings. Submeters shall be installed to measure water usage of individual rental dwelling units in accordance with the California Plumbing Code. 4.303.3 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1701.1 of the California Plumbing Code. ABBREVIATION DEFINITIONS: HCD Department of Housing and Community Development BSC California Building Standards Commission DSA-SS Division of the State Architect, Structural Safety OSHPD Office of Statewide Health Planning and Development LR Low Rise HR High Rise AA Additions and Alterations N New NOTE: THIS TABLE COMPILES THE DATA IN SECTION 4.303.1, AND IS INCLUDED AS A CONVENIENCE FOR THE USER. SECTION 4.102 DEFINITIONS 4.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) FRENCH DRAIN. A trench, hole or other depressed area loosely filled with rock, gravel, fragments of brick or similar pervious material used to collect or channel drainage or runoff water. WATTLES. Wattles are used to reduce sediment in runoff. Wattles are often constructed of natural plant materials such as hay, straw or similar material shaped in the form of tubes and placed on a downflow slope. Wattles are also used for perimeter and inlet controls. 4.106 SITE DEVELOPMENT 4.106.1 GENERAL. Preservation and use of available natural resources shall be accomplished through evaluation and careful planning to minimize negative effects on the site and adjacent areas. Preservation of slopes, management of storm water drainage and erosion controls shall comply with this section. 4.106.2 STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION. Projects which disturb less than one acre of soil and are not part of a larger common plan of development which in total disturbs one acre or more, shall manage storm water drainage during construction. In order to manage storm water drainage during construction, one or more of the following measures shall be implemented to prevent flooding of adjacent property, prevent erosion and retain soil runoff on the site. 1. Retention basins of sufficient size shall be utilized to retain storm water on the site. 2. Where storm water is conveyed to a public drainage system, collection point, gutter or similar disposal method, water shall be filtered by use of a barrier system, wattle or other method approved by the enforcing agency. 3. Compliance with a lawfully enacted storm water management ordinance. Note: Refer to the State Water Resources Control Board for projects which disturb one acre or more of soil, or are part of a larger common plan of development which in total disturbs one acre or more of soil. (Website: https://www.waterboards.ca.gov/water_issues/programs/stormwater/construction.html) 4.106.3 GRADING AND PAVING. Construction plans shall indicate how the site grading or drainage system will manage all surface water flows to keep water from entering buildings. Examples of methods to manage surface water include, but are not limited to, the following: 1. Swales 2. Water collection and disposal systems 3. French drains 4. Water retention gardens 5. Other water measures which keep surface water away from buildings and aid in groundwater recharge. Exception: Additions and alterations not altering the drainage path. 4.106.4 ELECTRIC VEHICLE (EV) CHARGING FOR NEW CONSTRUCTION. New construction shall comply with Sections 4.106.4.1 or 4.106.4.2 to facilitate future installation and use of EV chargers. Electric vehicle supply equipment (EVSE) shall be installed in accordance with the California Electrical Code, Article 625. Exceptions: 1. On a case-by-case basis, where the local enforcing agency has determined EV charging and infrastructure are not feasible based upon one or more of the following conditions: 1.1 Where there is no local utility power supply or the local utility is unable to supply adequate power. 1.2 Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements, directly related to the implementation of Section 4.106.4, may adversely impact the construction cost of the project. 2. Accessory Dwelling Units (ADU) and Junior Accessory Dwelling Units (JADU) without additional parking facilities. 4.106.4.1 New one- and two-family dwellings and townhouses with attached private garages. For each dwelling unit, install a listed raceway to accommodate a dedicated 208/240-volt branch circuit. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel and/or subpanel shall provide capacity to install a 40-ampere 208/240-volt minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit over current protective device. Exemption: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the proposed location of an EV charger at the time of original construction in accordance with the California Electrical Code. 4.106.4.1.1 Identification. The service panel or subpanel circuit directory shall identify the over current protective device space(s) reserved for future EV charging as "EV CAPABLE". The raceway termination location shall be permanently and visibly marked as "EV CAPABLE". 4.106.4.2 New multifamily dwellings, hotels and motels and new residential parking facilities.When parking is provided, parking spaces for new multifamily dwellings, hotels and motels shall meet the requirements of Sections 4.106.4.2.1 and 4.106.4.2.2. Calculations for spaces shall be rounded up to the nearest whole number. A parking space served by electric vehicle supply equipment or designed as a future EV charging space shall count as at least one standard automobile parking space only for the purpose of complying with any applicable minimum parking space requirements established by a local jurisdiction. See Vehicle Code Section 22511.2 for further details. 4.106.4.2.1 Multifamily development projects with less than 20 dwelling units; and hotels and motels with less than 20 sleeping units or guest rooms.The number of dwelling units, sleeping units or guest rooms shall be based on all buildings on a project site subject to this section. CHAPTER 3 GREEN BUILDING SECTION 301 GENERAL 301.1 SCOPE. Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code. Voluntary green building measures are also included in the application checklists and may be included in the design and construction of structures covered by this code, but are not required unless adopted by a city, county, or city and county as specified in Section 101.7. 301.1.1 Additions and alterations. [HCD] The mandatory provisions of Chapter 4 shall be applied to additions or alterations of existing residential buildings where the addition or alteration increases the building's conditioned area, volume, or size. The requirements shall apply only to and/or within the specific area of the addition or alteration. The mandatory provision of Section 4.106.4.2 may apply to additions or alterations of existing parking facilities or the addition of new parking facilities serving existing multifamily buildings. See Section 4.106.4.3 for application. Note: Repairs including, but not limited to, resurfacing, restriping and repairing or maintaining existing lighting fixtures are not considered alterations for the purpose of this section. Note: On and after January 1, 2014, residential buildings undergoing permitted alterations, additions, or improvements shall replace noncompliant plumbing fixtures with water-conserving plumbing fixtures.Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy or final permit approval by the local building department. See Civil Code Section 1101.1,et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates 301.2 LOW-RISE AND HIGH-RISE RESIDENTIAL BUILDINGS. [HCD] The provisions of individual sections of CALGreen may apply to either low-rise residential buildings high-rise residential buildings, or both. Individual sections will be designated by banners to indicate where the section applies specifically to low-rise only (LR) or high-rise only (HR). When the section applies to both low-rise and high-rise buildings, no banner will be used. SECTION 302 MIXED OCCUPANCY BUILDINGS 302.1 MIXED OCCUPANCY BUILDINGS. In mixed occupancy buildings, each portion of a building shall comply with the specific green building measures applicable to each specific occupancy. Exceptions: 1. [HCD] Accessory structures and accessory occupancies serving residential buildings shall comply with Chapter 4 and Appendix A4, as applicable. 2. [HCD] For purposes of CALGreen, live/work units, complying with Section 419 of the California Building Code, shall not be considered mixed occupancies. Live/Work units shall comply with Chapter 4 and Appendix A4, as applicable. 1.EV Capable. Ten (10) percent of the total number of parking spaces on a building site, provided for all types of parking facilities, shall be electric vehicle charging spaces (EV spaces) capable of supporting future Level 2 EVSE. Electrical load calculations shall demonstrate that the electrical panel service capacity and electrical system, including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs at all required EV spaces at a minimum of 40 amperes. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV + charging purposes as “EV CAPABLE” in accordance with the California Electrical Code. Exceptions: 1.When EV chargers (Level 2 EVSE) are installed in a number equal to or greater than the required number of EV capable spaces. 2.When EV chargers (Level 2 EVSE) are installed in a number less than the required number of EV capable spaces, the number of EV capable spaces required may be reduced by a number equal to the number of EV chargers installed. Notes: a.PLANS are intended to demonstrate the project’s capability and capacity for facilitating future EV charging. b.There is no requirement for EV spaces to be constructed or available until receptacles for EV charging or EV chargers are installed for use. 2.EV Ready. Twenty-five (25) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. For multifamily parking facilities, no more than one receptacle is required per dwelling unit when more than one parking space is provided for use by a single dwelling unit. Exception: Areas of parking facilities served by parking lifts. 4.106.4.2.2 Multifamily development projects with 20 or more dwelling units, hotels and motels with 20 or more sleeping units or guest rooms. The number of dwelling units, sleeping units or guest rooms shall be based on all buildings on a project site subject to this section. 1.EV Capable. Ten (10) percent of the total number of parking spaces on a building site, provided for all types of parking facilities, shall be electric vehicle charging spaces (EV spaces) capable of supporting future Level 2 EVSE. Electrical load calculations shall demonstrate that the electrical panel service capacity and electrical system, including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs at all required EV spaces at a minimum of 40 amperes. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE” in accordance with the California Electrical Code. Exception: When EV chargers (Level 2 EVSE) are installed in a number greater than five (5) percent of parking spaces required by Section 4.106.4.2.2, Item 3, the number of EV capable spaces required may be reduced by a number equal to the number of EV chargers installed over the five (5) percent required. Notes: a.PLANS shall show locations of future EV spaces. b.There is no requirement for EV spaces to be constructed or available until receptacles for EV charging or EV chargers are installed for use. 2.EV Ready. Twenty-five (25) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. For multifamily parking facilities, no more than one receptacle is required per dwelling unit when more than one parking space is provided for use by a single dwelling unit. Exception: Areas of parking facilities served by parking lifts. 3.EV Chargers. Five (5) percent of the total number of parking spaces shall be equipped with Level 2 EVSE. Where common use parking is provided, at least one EV charger shall be located in the common use parking area and shall be available for use by all residents or guests. When low power Level 2 EV charging receptacles or Level 2 EVSE are installed beyond the minimum required, an automatic load management system (ALMS) may be used to reduce the maximum required electrical capacity to each space served by the ALMS. The electrical system and any on-site distribution transformers shall have sufficient capacity to deliver at least 3.3 kW simultaneously to each EV charging station (EVCS) served by the ALMS. The branch circuit shall have a minimum capacity of 40 amperes, and installed EVSE shall have a capacity of not less than 30 amperes. ALMS shall not be used to reduce the minimum required electrical capacity to the required EV capable spaces. 4.106.4.2.2.1 Electric vehicle charging stations (EVCS). Electric vehicle charging stations required by Section 4.106.4.2.2, Item 3, shall comply with Section 4.106.4.2.2.1. Exception: Electric vehicle charging stations serving public accommodations, public housing, motels and hotels shall not be required to comply with this section. See California Building Code, Chapter 11B, for applicable requirements. 4.106.4.2.2.1.1 Location. EVCS shall comply with at least one of the following options: 1.The charging space shall be located adjacent to an accessible parking space meeting the requirements of the California Building Code, Chapter 11A, to allow use of the EV charger from the accessible parking space. 2.The charging space shall be located on an accessible route, as defined in the California Building Code, Chapter 2, to the building. Exception: Electric vehicle charging stations designed and constructed in compliance with the California Building Code, Chapter 11B, are not required to comply with Section 4.106.4.2.2.1.1 and Section 4.106.4.2.2.1.2, Item 3. 4.106.4.2.2.1.2 Electric vehicle charging stations (EVCS) dimensions. The charging spaces shall be designed to comply with the following: 1.The minimum length of each EV space shall be 18 feet (5486 mm). 2.The minimum width of each EV space shall be 9 feet (2743 mm). 3.One in every 25 charging spaces, but not less than one, shall also have an 8-foot (2438 mm) wide minimum aisle. A 5-foot (1524 mm) wide minimum aisle shall be permitted provided the minimum width of the EV space is 12 feet (3658 mm). a.Surface slope for this EV space and the aisle shall not exceed 1 unit vertical in 48 units horizontal (2.083 percent slope) in any direction. 4.106.4.2.2.1.3 Accessible EV spaces. In addition to the requirements in Sections 4.106.4.2.2.1.1 and 4.106.4.2.2.1.2, all EVSE, when installed, shall comply with the accessibility provisions for EV chargers in the California Building Code, Chapter 11B. EV ready spaces and EVCS in multifamily developments shall comply with California Building Code, Chapter 11A, Section 1109A. 4.106.4.2.3 EV space requirements. 1.Single EV space required. Install a listed raceway capable of accommodating a 208/240-volt dedicated branch circuit. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or enclosure in close proximity to the location or the proposed location of the EV space. PLANS shall identify the raceway termination point, receptacle or charger location, as applicable. The service panel and/ or subpanel shall have a 40-ampere minimum dedicated branch circuit, including branch circuit overcurrent protective device installed, or space(s) reserved to permit installation of a branch circuit overcurrent protective device. Exception: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the location or the proposed location of the EV space, at the time of original construction in accordance with the California Electrical Code. 2.Multiple EV spaces required. PLANS shall indicate the raceway termination point and the location of installed or future EV spaces, receptacles or EV chargers. PLANS shall also provide information on amperage of installed or future receptacles or EVSE, raceway method(s), wiring schematics and electrical load calculations. Plan design shall be based upon a 40-ampere minimum branch circuit. Required raceways and related components that are planned to be installed underground, enclosed, inaccessible or in concealed areas and spaces shall be installed at the time of original construction. Exception: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the location or the proposed location of the EV space at the time of original construction in accordance with the California Electrical Code. 4.106.4.2.4 Identification. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE” in accordance with the California Electrical Code. 4.106.4.2.5 Electric Vehicle Ready Space Signage. Electric vehicle ready spaces shall be identified by signage or pavement markings, in compliance with Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s). 4.106.4.3 Electric vehicle charging for additions and alterations of parking facilities serving existing multifamily buildings. When new parking facilities are added, or electrical systems or lighting of existing parking facilities are added or altered and the work requires a building permit, ten (10) percent of the total number of parking spaces added or altered shall be electric vehicle charging spaces (EV spaces) capable of supporting future Level 2 EVSE. Notes: 1.PLANS are intended to demonstrate the project’s capability and capacity for facilitating future EV charging. 2.There is no requirement for EV spaces to be constructed or available until EV chargers are installed for use. SECTION 4.501 GENERAL 4.501.1 Scope.The provisions of this chapter shall outline means of reducing the quality of air contaminants that are odorous, irritating and/or harmful to the comfort and well being of a building's installers, occupants and neighbors. SECTION 4.502 DEFINITIONS 5.102.1 DEFINITIONS.The following terms are defined in Chapter 2 (and are included here for reference) AGRIFIBER PRODUCTS. Agrifiber products include wheatboard, strawboard, panel substrates and door cores, not including furniture, fixtures and equipment (FF&E) not considered base building elements. COMPOSITE WOOD PRODUCTS. Composite wood products include hardwood plywood, particleboard and medium density fiberboard. "Composite wood products" does not include hardboard, structural plywood, structural panels, structural composite lumber, oriented strand board, glued laminated timber, prefabricated wood I-joists or finger-jointed lumber, all as specified in California Code of regulations (CCR), title 17, Section 93120.1. DIRECT-VENT APPLIANCE. A fuel-burning appliance with a sealed combustion system that draws all air for combustion from the outside atmosphere and discharges all flue gases to the outside atmosphere. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. Y N/AY N/AY N/AY N/A RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 1 (January 2023)Y = YES N/A = NOT APPLICABLE RESPON. PARTY = RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) TABLE H-2 STANDARDS FOR COMMERCIAL PRE-RINSE SPRAY VALUES MANUFACTURED ON OR AFTER JANUARY 28, 2019 PRODUCT CLASS [spray force in ounce force (ozf)]MAXIMUM FLOW RATE (gpm) Product Class 1 (≤ 5.0 ozf)1.0000 Product Class 2 (> 5.0 ozf and ≤ 8.0 ozf)1.2000 Product Class 3 (> 8.0 ozf)1.2800 TABLE - MAXIMUM FIXTURE WATER USE FIXTURE TYPE FLOW RATE SHOWER HEADS (RESIDENTIAL) 1.8 GMP @ 80 PSI LAVATORY FAUCETS (RESIDENTIAL) MAX. 1.2 GPM @ 60 PSI MIN. 0.8 GPM @ 20 PSI LAVATORY FAUCETS IN COMMON & PUBLIC USE AREAS 0.5 GPM @ 60 PSI KITCHEN FAUCETS 1.8 GPM @ 60 PSI METERING FAUCETS 0.2 GAL/CYCLE WATER CLOSET 1.28 GAL/FLUSH URINALS 0.125 GAL/FLUSH x x x x x x x x x x x x x x x x x x x DIVISION 4.2 ENERGY EFFICIENCY 4.201 GENERAL 4.201.1 SCOPE. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards. x 4.304 OUTDOOR WATER USE 4.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. Residential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources' Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent. NOTES: 1. The Model Water Efficient Landscape Ordinance (MWELO) is located in the California Code Regulations, Title 23, Chapter 2.7, Division 2. MWELO and supporting documents, including water budget calculator, are available at: https://www.water.ca.gov/ x DIVISION 4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE 4.406.1 RODENT PROOFING. Annular spaces around pipes, electric cables, conduits or other openings in sole/bottom plates at exterior walls shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry or a similar method acceptable to the enforcing agency. 4.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING 4.408.1 CONSTRUCTION WASTE MANAGEMENT. Recycle and/or salvage for reuse a minimum of 65 percent of the non-hazardous construction and demolition waste in accordance with either Section 4.408.2, 4.408.3 or 4.408.4, or meet a more stringent local construction and demolition waste management ordinance. Exceptions: 1. Excavated soil and land-clearing debris. 2. Alternate waste reduction methods developed by working with local agencies if diversion or recycle facilities capable of compliance with this item do not exist or are not located reasonably close to the jobsite. 3. The enforcing agency may make exceptions to the requirements of this section when isolated jobsites are located in areas beyond the haul boundaries of the diversion facility. x x           1011 W Second St 5/1/2025 GN-2 GARCIA RESIDENCE SHEET PROPERTY OWNER: JUAN GARCIA (949) 627-2074 REV DATE DESCRIPTION 10/16/23A THERE SHALL BE NO CHANGES OR DEVIATION ON THESE PLANS WITHOUT TH E CONSENT OF PLAN AND PERMIT IN C. NOTES AND DETAILS ON THE DRAW INGS SHALL TAKE PRECEDENCE OVER GENERAL NOTE S AND TYPICAL DETAILS. WHERE NO DETAILS SH OWN OR NOTED ON THE DRAWINGS, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK.CONTRACTOR SHALL VERI FY ALL PLANS, EXISTING DIMENSIO NS AND FIELD CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY TO PLAN AND PERMIT INC ANY DISCREPANCIES IN WR ITING PRIOR TO THE COMMENCEMENT OF ANY WOR K OR BE RESPONSIBLE FOR SAME. TH E S E D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F P L A N A N D P E R M I T I N C A N D S H A L L N O T B E U S E D I N C O N N E CT I O N W I T H A N Y O T H E R W O R K E X C E P T B Y A G R E E M E N T W I T H P L A N A N D P E R M I T I N C . B Y U S I N G T H E S E P L A N S , T H E U S E R A G R E E S T O R E L E A S E P L A N A ND P E R M I T I N C F R O M A N Y A N D A L L C L A I M S , L I A B I L I T I E S , S U I T S , A N D D E M A N D S O N A C C O U N T O F A N Y I N J U R Y , D A M A G E O R L O S S O R P E R S O N S O R P RO P E R T Y , I N C L U D I N G I N J U R Y O R D E A T H , O R E C O N O M I C L O S S E S , A R I S I N G O U T O F T H E U S E O F T H E S E P L A N S . SKETCH FOR REVIEW 11/17/23 B 90PD FOR APPROVALC 01/02/240 100PD FOR SUBMITTAL 10/31/23 90PD FOR REVIEW PROPERTY ADDRESS: 1011 W 2ND ST, SANTA ANA, CA 92703 PLAN AND PERMIT INC. ARCHITECTURAL DESIGN SERVICES 9891 IRVINE CENTER DR #200 IRVINE, CA 92618 (714)-715-0923 biz@planandpermit.com LOCATION QR CODE: STATE OF CAL IFORNIAEXP. DATE L I C E NS E D A R CHI T E C T C - 34643 06/30/2025 SIGNATURE PAUL SAN GEMINO GENERAL NOTES MAXIMUM INCREMENTAL REACTIVITY (MIR). The maximum change in weight of ozone formed by adding a compound to the "Base Reactive Organic Gas (ROG) Mixture" per weight of compound added, expressed to hundredths of a gram (g O³/g ROC). Note: MIR values for individual compounds and hydrocarbon solvents are specified in CCR, Title 17, Sections 94700 and 94701. MOISTURE CONTENT. The weight of the water in wood expressed in percentage of the weight of the oven-dry wood. PRODUCT-WEIGHTED MIR (PWMIR). The sum of all weighted-MIR for all ingredients in a product subject to this article. The PWMIR is the total product reactivity expressed to hundredths of a gram of ozone formed per gram of product (excluding container and packaging). Note: PWMIR is calculated according to equations found in CCR, Title 17, Section 94521 (a). REACTIVE ORGANIC COMPOUND (ROC). Any compound that has the potential, once emitted, to contribute to ozone formation in the troposphere. VOC. A volatile organic compound (VOC) broadly defined as a chemical compound based on carbon chains or rings with vapor pressures greater than 0.1 millimeters of mercury at room temperature. These compounds typically contain hydrogen and may contain oxygen, nitrogen and other elements. See CCR Title 17, Section 94508(a). 4.503 FIREPLACES 4.503.1 GENERAL. Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed woodstove or pellet stove shall comply with U.S. EPA New Source Performance Standards (NSPS) emission limits as applicable, and shall have a permanent label indicating they are certified to meet the emission limits. Woodstoves, pellet stoves and fireplaces shall also comply with applicable local ordinances. 4.504 POLLUTANT CONTROL 4.504.1 COVERING OF DUCT OPENINGS & PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION. At the time of rough installation, during storage on the construction site and until final startup of the heating, cooling and ventilating equipment, all duct and other related air distribution component openings shall be covered with tape, plastic, sheet metal or other methods acceptable to the enforcing agency to reduce the amount of water, dust or debris which may enter the system. 4.504.2 FINISH MATERIAL POLLUTANT CONTROL. Finish materials shall comply with this section. 4.504.2.1 Adhesives, Sealants and Caulks. Adhesives, sealant and caulks used on the project shall meet the requirements of the following standards unless more stringent local or regional air pollution or air quality management district rules apply: 1. Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant primers and caulks shall comply with local or regional air pollution control or air quality management district rules where applicable or SCAQMD Rule 1168 VOC limits, as shown in Table 4.504.1 or 4.504.2, as applicable. Such products also shall comply with the Rule 1168 prohibition on the use of certain toxic compounds (chloroform, ethylene dichloride, methylene chloride, perchloroethylene and tricloroethylene), except for aerosol products, as specified in Subsection 2 below. 2. Aerosol adhesives, and smaller unit sizes of adhesives, and sealant or caulking compounds (in units of product, less packaging, which do not weigh more than 1 pound and do not consist of more than 16 fluid ounces) shall comply with statewide VOC standards and other requirements, including prohibitions on use of certain toxic compounds, of California Code of Regulations, Title 17, commencing with section 94507. 4.504.2.2 Paints and Coatings. Architectural paints and coatings shall comply with VOC limits in Table 1 of the ARB Architectural Suggested Control Measure, as shown in Table 4.504.3, unless more stringent local limits apply. The VOC content limit for coatings that do not meet the definitions for the specialty coatings categories listed in Table 4.504.3 shall be determined by classifying the coating as a Flat, Nonflat or Nonflat-High Gloss coating, based on its gloss, as defined in subsections 4.21, 4.36, and 4.37 of the 2007 California Air Resources Board, Suggested Control Measure, and the corresponding Flat, Nonflat or Nonflat-High Gloss VOC limit in Table 4.504.3 shall apply. 4.504.2.3 Aerosol Paints and Coatings. Aerosol paints and coatings shall meet the Product-weighted MIR Limits for ROC in Section 94522(a)(2) and other requirements, including prohibitions on use of certain toxic compounds and ozone depleting substances, in Sections 94522(e)(1) and (f)(1) of California Code of Regulations, Title 17, commencing with Section 94520; and in areas under the jurisdiction of the Bay Area Air Quality Management District additionally comply with the percent VOC by weight of product limits of Regulation 8, Rule 49. 4.504.2.4 Verification. Verification of compliance with this section shall be provided at the request of the enforcing agency. Documentation may include, but is not limited to, the following: 1. Manufacturer's product specification. 2. Field verification of on-site product containers. 703 VERIFICATIONS 703.1 DOCUMENTATION. Documentation used to show compliance with this code shall include but is not limited to, PLANS, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which demonstrate substantial conformance. When specific documentation or special inspection is necessary to verify compliance, that method of compliance will be specified in the appropriate section or identified applicable checklist. 4.505 INTERIOR MOISTURE CONTROL 4.505.1 General. Buildings shall meet or exceed the provisions of the California Building Standards Code. 4.505.2 CONCRETE SLAB FOUNDATIONS. Concrete slab foundations required to have a vapor retarder by California Building Code, Chapter 19, or concrete slab-on-ground floors required to have a vapor retarder by the California Residential Code, Chapter 5, shall also comply with this section. 4.505.2.1 Capillary break. A capillary break shall be installed in compliance with at least one of the following: 1. A 4-inch (101.6 mm) thick base of 1/2 inch (12.7mm) or larger clean aggregate shall be provided with a vapor barrier in direct contact with concrete and a concrete mix design, which will address bleeding, shrinkage, and curling, shall be used. For additional information, see American Concrete Institute, ACI 302.2R-06. 2. Other equivalent methods approved by the enforcing agency. 3. A slab design specified by a licensed design professional. 4.505.3 MOISTURE CONTENT OF BUILDING MATERIALS. Building materials with visible signs of water damage shall not be installed. Wall and floor framing shall not be enclosed when the framing members exceed 19 percent moisture content. Moisture content shall be verified in compliance with the following: 1. Moisture content shall be determined with either a probe-type or contact-type moisture meter.Equivalent moisture verification methods may be approved by the enforcing agency and shall satisfy requirements found in Section 101.8 of this code. 2. Moisture readings shall be taken at a point 2 feet (610 mm) to 4 feet (1219 mm) from the grade stamped end of each piece verified. 3. At least three random moisture readings shall be performed on wall and floor framing with documentation acceptable to the enforcing agency provided at the time of approval to enclose the wall and floor framing. Insulation products which are visibly wet or have a high moisture content shall be replaced or allowed to dry prior to enclosure in wall or floor cavities. Wet-applied insulation products shall follow the manufacturers' drying recommendations prior to enclosure. 4.506 INDOOR AIR QUALITY AND EXHAUST 4.506.1 Bathroom exhaust fans. Each bathroom shall be mechanically ventilated and shall comply with the following: 1. Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building. 2. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a humidity control. a. Humidity controls shall be capable of adjustment between a relative humidity range less than or equal to 50% to a maximum of 80%. A humidity control may utilize manual or automatic means of adjustment. b. A humidity control may be a separate component to the exhaust fan and is not required to be integral (i.e., built-in) Notes: 1. For the purposes of this section, a bathroom is a room which contains a bathtub, shower or tub/shower combination. 2. Lighting integral to bathroom exhaust fans shall comply with the California Energy Code. 4.507 ENVIRONMENTAL COMFORT 4.507.2 HEATING AND AIR-CONDITIONING SYSTEM DESIGN. Heating and air conditioning systems shall be sized, designed and have their equipment selected using the following methods: 1. The heat loss and heat gain is established according to ANSI/ACCA 2 Manual J - 2011 (Residential Load Calculation), ASHRAE handbooks or other equivalent design software or methods. 2. Duct systems are sized according to ANSI/ACCA 1 Manual D - 2014 (Residential Duct Systems), ASHRAE handbooks or other equivalent design software or methods. 3. Select heating and cooling equipment according to ANSI/ACCA 3 Manual S - 2014 (Residential Equipment Selection), or other equivalent design software or methods. Exception: Use of alternate design temperatures necessary to ensure the system functions are acceptable. TABLE 4.504.5 - FORMALDEHYDE LIMITS1 MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.0500 HARDWOOD PLYWOOD COMPOSITE CORE 0.0500 PARTICLE BOARD 0.0900 MEDIUM DENSITY FIBERBOARD 0.1100 THIN MEDIUM DENSITY FIBERBOARD2 0.1300 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIF. AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIF. CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16" (8 MM). DIVISION 4.5 ENVIRONMENTAL QUALITY (continued) 4.504.3 CARPET SYSTEMS. All carpet installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.1 Carpet cushion. All carpet cushion installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.2 Carpet adhesive. All carpet adhesive shall meet the requirements of Table 4.504.1. 4.504.4 RESILIENT FLOORING SYSTEMS. Where resilient flooring is installed , at least 80% of floor area receiving resilient flooring shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. hhtps://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.5 COMPOSITE WOOD PRODUCTS. Hardwood plywood, particleboard and medium density fiberboard composite wood products used on the interior or exterior of the buildings shall meet the requirements for formaldehyde as specified in ARB's Air Toxics Control Measure for Composite Wood (17 CCR 93120 et seq.), by or before the dates specified in those sections, as shown in Table 4.504.5 4.504.5.1 Documentation. Verification of compliance with this section shall be provided as requested by the enforcing agency. Documentation shall include at least one of the following: 1. Product certifications and specifications. 2. Chain of custody certifications. 3. Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR, Title 17, Section 93120, et seq.). 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered Wood Association, the Australian AS/NZS 2269, European 636 3S standards, and Canadian CSA 0121, CSA 0151, CSA 0153 and CSA 0325 standards. 5. Other methods acceptable to the enforcing agency. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. Y N/AY N/AY N/AY N/A RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 2 (January 2023)Y = YES N/A = NOT APPLICABLE RESPON. PARTY = RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) x x x x x x x x x x x x x x x x x x x (Less Water and Less Exempt Compounds in Grams per Liter) ARCHITECTURAL APPLICATIONS VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT & ASPHALT TILE ADHESIVES 50 DRYWALL & PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVE 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP & TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD)50 WOOD 30 FIBERGLASS 80 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. TABLE 4.504.1 - ADHESIVE VOC LIMIT1,2 TABLE 4.504.2 - SEALANT VOC LIMIT (Less Water and Less Exempt Compounds in Grams per Liter) SEALANTS VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NON-POROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 TABLE 4.504.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS2,3 GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS COATING CATEGORY VOC LIMIT FLAT COATINGS 50 NON-FLAT COATINGS 100 NONFLAT-HIGH GLOSS COATINGS 150 SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS)500 HIGH TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS1 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS, & UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB & TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & EXEMPT COMPOUNDS 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE. 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEB. 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. CHAPTER 7 INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS 702 QUALIFICATIONS 702.1 INSTALLER TRAINING. HVAC system installers shall be trained and certified in the proper installation of HVAC systems including ducts and equipment by a nationally or regionally recognized training or certification program. Uncertified persons may perform HVAC installations when under the direct supervision and responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC systems. Examples of acceptable HVAC training and certification programs include but are not limited to the following: 1. State certified apprenticeship programs. 2. Public utility training programs. 3. Training programs sponsored by trade, labor or statewide energy consulting or verification organizations. 4. Programs sponsored by manufacturing organizations. 5. Other programs acceptable to the enforcing agency. 702.2 SPECIAL INSPECTION [HCD]. When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition to other certifications or qualifications acceptable to the enforcing agency, the following certifications or education may be considered by the enforcing agency when evaluating the qualifications of a special inspector: 1. Certification by a national or regional green building program or standard publisher. 2. Certification by a statewide energy consulting or verification organization, such as HERS raters, building performance contractors, and home energy auditors. 3. Successful completion of a third party apprentice training program in the appropriate trade. 4. Other programs acceptable to the enforcing agency. Notes: 1. Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate homes in California according to the Home Energy Rating System (HERS). [BSC] When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition, the special inspector shall have a certification from a recognized state, national or international association, as determined by the local agency. The area of certification shall be closely related to the primary job function, as determined by the local agency. Note: Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. x x           1011 W Second St 5/1/2025 GN-3 GARCIA RESIDENCE SHEET PROPERTY OWNER: JUAN GARCIA (949) 627-2074 REV DATE DESCRIPTION 10/16/23A THERE SHALL BE NO CHANGES OR DEVIATION ON THESE PLANS WITHOUT TH E CONSENT OF PLAN AND PERMIT IN C. NOTES AND DETAILS ON THE DRAW INGS SHALL TAKE PRECEDENCE OVER GENERAL NOTE S AND TYPICAL DETAILS. WHERE NO DETAILS SH OWN OR NOTED ON THE DRAWINGS, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK.CONTRACTOR SHALL VERI FY ALL PLANS, EXISTING DIMENSIO NS AND FIELD CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY TO PLAN AND PERMIT INC ANY DISCREPANCIES IN WR ITING PRIOR TO THE COMMENCEMENT OF ANY WOR K OR BE RESPONSIBLE FOR SAME. TH E S E D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F P L A N A N D P E R M I T I N C A N D S H A L L N O T B E U S E D I N C O N N E CT I O N W I T H A N Y O T H E R W O R K E X C E P T B Y A G R E E M E N T W I T H P L A N A N D P E R M I T I N C . B Y U S I N G T H E S E P L A N S , T H E U S E R A G R E E S T O R E L E A S E P L A N A ND P E R M I T I N C F R O M A N Y A N D A L L C L A I M S , L I A B I L I T I E S , S U I T S , A N D D E M A N D S O N A C C O U N T O F A N Y I N J U R Y , D A M A G E O R L O S S O R P E R S O N S O R P RO P E R T Y , I N C L U D I N G I N J U R Y O R D E A T H , O R E C O N O M I C L O S S E S , A R I S I N G O U T O F T H E U S E O F T H E S E P L A N S . SKETCH FOR REVIEW 11/17/23 B 90PD FOR APPROVALC 01/02/240 100PD FOR SUBMITTAL 10/31/23 90PD FOR REVIEW PROPERTY ADDRESS: 1011 W 2ND ST, SANTA ANA, CA 92703 PLAN AND PERMIT INC. ARCHITECTURAL DESIGN SERVICES 9891 IRVINE CENTER DR #200 IRVINE, CA 92618 (714)-715-0923 biz@planandpermit.com LOCATION QR CODE: STATE OF CAL IFORNIAEXP. DATE L I C E NS E D A R CHI T E C T C - 34643 06/30/2025 SIGNATURE PAUL SAN GEMINO GENERAL NOTES ABBREVIATIONS 1. CONSTRUCTION WASTE REDUCTION, DISPOSAL, AND RECYCLING SHALL COMPLY WITH REQUIREMENT OF CALGREEN DIVISION 4.4 MATERIAL CONSERVATION AND RESOURCE EFFICENCY AND/OR AHJ REGULATIONS, WHICHEVER IS MORE STRICT. 2. CONTRACTOR SHALL OBTAIN ALL PERMITS, AND CHECK GOVERNING AUTHORITIES SPECIFICATIONS FOR CONSTRUCTION INCLUDING REMOVAL OR RELOCATION OF EXISTING UTILITIES 3. CONTRACTOR SHALL GIVE NOTICES REQUIRED BY GOVERNMENTAL AUTHORITIES AND BY THE OWNER OR HIS REPRESENTATIVE. 4. CONTRACTOR SHALL VISIT THE JOB SITE AND SHALL FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS AS TO THE COST THEREOF. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN (PRIOR TO) FINALIZING BIDS AND PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF "PLAN AND PERMIT INC" PRIOR TO THE COMMENCEMENT OF WORK. NO COMPENSATION WILL BE AWARDED BASED ON CLAIM OF LACK OF KNOWLEDGE OF FIELD CONDITIONS. NOTIFY PLAN AND PERMIT INC. PROMPTLY, SHOULD ANY QUESTIONS ARISE PERTAINING TO THE PLANS, OR IF CONDITIONS ARE FOUND THAT MAY PREVENT THE PROPER EXECUTION OF ANY PORTION OF THE WORK. THE CONTRACTOR SHALL CORRECT ALL ERRORS, DISCREPANCIES, OR OMISSIONS WHICH RESULT FROM HIS FAILURE TO NOTIFY "PLAN AND PERMIT INC". BEFORE STARTING FABRICATION OR INSTALLATION OF ANY ITEM OR WORK. 5. CONTRACTOR SHALL NOTIFY DESIGNER OF ANTICIPATED FINAL INSPECTION DATE TWO WEEKS IN ADVANCE, IN WRITING. 6. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION INCLUDING SHORING AND TEMPORARY BRACING AND TAKE ALL NECESSARY MEASURES TO INSURE THE SAFETY OF ALL PERSONS AND STRUCTURES NEXT TO THE SITE. CARE SHALL BE TAKEN TO PROTECT FROM ANY DAMAGE ALL TREES AND VEGETATION ON SITE AND ON ADJOINING PROPERTIES. ANY TRIMMING OR OTHER ALTERATION DONE TO TREES SHALL BE DONE SO ONLY BY APPROVAL OF THE OWNER. 7. "PLAN AND PERMIT INC" SHALL NOT BE HELD RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO CONFORM TO THE PLANS, CODES, REGULATIONS AND LAWS, OR FOR THE PERFORMANCE OF THE CONTRACTOR IN A TIMELY AND SATISFACTORY MANNER. 8. "PLAN AND PERMIT INC" WILL NOT PROVIDE REGULAR ON SITE CONTRACT ADMINISTRATION AND IS AVAILABLE ONLY AT REQUEST OF THE OWNER. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR QUALITY CONTROL AND CONSTRUCTION STANDARDS FOR THIS PROJECT. 9. THESE PLANS ARE FOR GENERAL CONSTRUCTION PURPOSES ONLY. THEY ARE NOT EXHAUSTIVELY DETAILED NOR FULLY SPECIFIED. THE DRAWINGS WERE PREPARED TO A LEVEL OF COMPLETION SATISFACTORY FOR BUILDING PERMIT PURPOSES AND FOR CONSTRUCTION BY A KNOWLEDGEABLE AND EXPERIENCED CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR PREPARATION OF ANY SUPPLEMENTAL PRODUCT SPECIFICATIONS, COORDINATION AND INSTALLATION OF ALL MATERIALS AND EQUIPMENT. 10.CONTRACTOR SHALL DELIVER TO OWNER, UPON PROJECT CLOSE-OUT THE PERMIT AND RECORD (AS-BUILT) SETS OF PLANS TOGETHER WITH OPERATION AND MAINTENANCE DATA, WARRANTIES, BONDS IF APPLICABLE, CERTIFICATES OF COMPLIANCE REQUIRED BY REGULATORY AUTHORITIES AND SUCH OTHER PROJECT RECORDS AS MAY BE REQUESTED BY THE OWNER. 11.CLEAN-UP: THE CONTRACTOR SHALL REMOVE ALL DEBRIS FROM THE BUILDING SITE AND INSIDE BUILDING THE WORK AS CLEAR OF RUBBISH AS POSSIBLE DURING THE COURSE OF THE WORK. BEFORE FINAL NOTICE OF COMPLETION, THE BUILDING WILL BE FULLY CLEANED, INCLUDING ALL GLASS POLISHED, SCRUBBED AND CLEANED, AND THE BUILDING SHALL BE SUITABLE FOR IMMEDIATE OCCUPANCY BY OWNER. CONTRACTOR AND SUBCONTRACTOR SHALL MAINTAIN THE PREMISES, CLEAN AND FREE OF ALL TRASH AND DEBRIS, AND SHALL PROTECT ALL ADJACENT WORK FROM DAMAGE, SOILING, PAINT OVER-SPRAY, DUST, ETC. SHALL PROVIDE ADEQUATE TRASH CONTAINERS FOR THE DISPOSAL OF UNUSED MATERIAL AND TRASH. 12.PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT AND APPURTENANCES, AND LABOR NECESSARY TO EFFECT ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 13.DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS AND/OR DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THE WORK. 14.DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 15.CONTRACTOR SHALL RECEIVE CLARIFICATION IN WRITING, AND SHALL RECEIVE IN WRITING AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEMS NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 16.CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING THE BEST CONSTRUCTION SKILLS AND ATTENTION. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER CONTRACT, UNLESS OTHERWISE NOTED. 17.CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE WORK AREA, ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. 18.CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION SHALL BE IN CONFORMANCE WITH JURISDICTIONAL OR STATE AND LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL AND COORDINATED WITH LOCAL REGULATORY AUTHORITIES. 19.GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE WORK OF ALL OF OWNER'S SUBCONTRACTORS AND FIXTURE CONTRACTORS INCLUDING THE PERFORMANCE OF SUCH MISCELLANEOUS WORK AS MAY BE NECESSARY FOR THEM TO COMPLETE THEIR WORK. 20.INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 21.TEMPERED GLASS SHALL BE PERMANENTLY IDENTIFIED AND VISIBLE WHEN THE UNIT IS GLAZED. 22.ALL NEW GLAZING (PENETRATIONS) WILL BE INSTALLED WITH A CERTIFYING LABEL ATTACHED, SHOWING THE U - VALUE. 23.MAKE NECESSARY PROVISIONS TO PROTECT EXISTING SURFACES, EQUIPMENT, IMPROVEMENTS, PIPING ETC. AND IMMEDIATELY REPAIR ANY DAMAGE THAT OCCURS DURING CONSTRUCTION. 24.IN DRILLING HOLES INTO CONCRETE WHETHER FOR FASTENING OR ANCHORING PURPOSES, OR PENETRATIONS THROUGH THE FLOOR FOR CONDUIT RUNS, PIPE RUNS, ETC., MUST BE CLEARLY UNDERSTOOD THAT REINFORCING STEEL SHALL NOT BE DRILLED INTO, CUT OR DAMAGED UNDER ANY CIRCUMSTANCES (UNLESS NOTED OTHERWISE). LOCATIONS OF REINFORCING STEEL ARE NOT DEFINITELY KNOWN AND THEREFORE MUST BE SEARCHED FOR BY APPROPRIATE METHODS AND EQUIPMENT. 25.SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH U.L. LISTED AND FIRE CODE APPROVED MATERIALS. 26.KEEP CONTRACT AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH. EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OF THE OWNER SHALL BE REMOVED. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL ITEMS UNTIL COMPLETION OF CONSTRUCTION. 27.ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO APPLICABLE REGULATORY AUTHORITIES. 28.CONTRACTOR TO VERIFY IN FIELD EXISTING CONDITION STRUCTURAL SYSTEM AND PROPOSED SCOPE OF WORK (DEMOLITION). CONTRACTOR ON DISCOVERY OF DISCREPANCY BETWEEN PROPOSED SCOPE AND EXISTING CONDITION WILL NOTIFY IMMEDIATE ARCHITECT AND STRUCTURAL ENGINEER. 29.CONTRACTOR TO COORDINATE LOCATION OF DEDICATED OUTLETS AND VENTS WITH FINAL LOCATION OF EQUIPMENT. 30.CONTRACTOR TO COORDINATE LOCATION OF DEDICATED OUTLETS AND VENTS WITH FINAL LOCATION OF EQUIPMENT 31.CONTRACTOR TO COORDINATE ROUTING OF VENTS AND EXHAUST DUCTING TO ROOF AND/OR EXTERIOR WALL PER (E) CONDITION. 32.CONTRACTOR TO COORDINATE 2X FRAMING PER STRUCTURAL AND T24 SHEETS. 33.CONTRACTOR TO COORDINATED REQUIRED RO PER WINDOW AND DOOR SCHEDULE. GENERAL NOTES 30.CONTRACTOR SHALL ENSURE THAT ALL WORK IS PERFORMED IN A PROFESSIONAL AND WORKMANLIKE MANNER BY SKILLED MECHANICS OF THE TRADE AND SHALL REPLACE ANY ITEMS DAMAGED BY THE CONTRACTOR ' S OR SUBCONTRACTORS ' PERFORMANCE AT NO ADDITIONAL COST TO THE OWNER . 31.SUBCONTRACTORS AND SUPPLIERS ARE HEREBY NOTIFIED THAT THEY ARE TO CONFER AND COOPERATE FULLY WITH EACH OTHER DURING THE COURSE OF CONSTRUCTION TO DETERMINE THE EXACT EXTENT AND OVERLAP OF EACH OTHER'S WORK AND TO SUCCESSFULLY COMPLETE THE EXECUTION OF THE WORK AND IN A TIMELY MANNER. 32.CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, AND FOR THE SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. FIELD OBSERVATIONS BY PLAN AND PERMIT INC. OR STRUCTURAL ENGINEER SHALL NOT BE CONSTRUED AS REVIEWING NOR APPROVING THE SAME. 33.CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY SHORING, BRACING, SUPPORTS, ETC., AS MAY BE REQUIRED TO SAFELY COMPLETE THE CONSTRUCTION PROCESS, AND SHALL BE RESPONSIBLE FOR THE DESIGN, ADEQUACY, AND SAFETY OF THIS WORK. FIELD OBSERVATIONS BY PLAN AND PERMIT INC. OR STRUCTURAL ENGINEER SHALL NOT INCLUDE ITEMS AS STATED HEREIN. 34.NO STORAGE OR PLACEMENT OF HAZARDOUS, TOXIC, CARCINOGENIC, OR FLAMMABLE MATERIALS SHALL BE PERMITTED ON THE SITE. DISPOSAL OF SAID MATERIALS SHALL BE IN A SAFE MANNER AND SHALL COMPLY WITH ALL CURRENT APPLICABLE LAWS AND REGULATIONS. 35.CONTRACTOR SHALL INSPECT AND VERIFY THAT THE PROJECT WORK SPACE IS ASBESTOS FREE. THE CONTRACTOR MUST NOTIFY THE CITY OFFICIALS, OWNER AND DESIGNER IMMEDIATELY, IF THE PRESENCE OF ASBESTOS, OR ANY HAZARDOUS MATERIAL IS DETECTED OR SUSPECTED. 36.PLAN AND PERMIT INC. DOES NOT GUARANTEE THE GENERAL CONTRACTOR'S AND /OR SUBCONTRACTORS' PERFORMANCE, AND NO PROVISIONS OF THE CONTRACT DOCUMENTS PERFORMANCE, INCOMPETENCE, OR ERRORS OR OMISSIONS OR COMMISSION OF THE SUBCONTRACTOR. 37.THIS IS A BUILDERS SET OF DRAWINGS. THESE NOTES ARE TO PROVIDE GENERAL INFORMATION ONLY. SPECIFICATIONS ARE TO BE PROVIDED BY OWNER. FOR CONVENIENCE OF REFERENCE AND TO FACILITATE THE LETTING OF CONTRACTS AND SUBCONTRACTS, THE NOTES ARE SEPARATE, NOT TITLED SECTIONS. SUCH SEPARATIONS SHALL NOT OPERATE TO MAKE PLAN AND PERMIT INC. OR ARBITER TO ESTABLISH LIMITS BETWEEN THE CONTRACTOR AND SUBCONTRACTORS. DEFINITIONS 1. THE DESIGN AND WORK SHALL COMPLY WITH THE LATEST ADOPTED EDITIONS OF THE CALIFORNIA BUILDING STANDARDS CODE FOUND IN STATE OF CALIFORNIA TITLE 24 CCR AS AMENDED AND ADOPTED BY THE CITY. HAVING JURISDICTION (SEE MUNICIPAL CODE). IN THE CASE OF CONFLICT WITH THESE REGULATIONS AND THE CONTRACT DOCUMENTS, THE MOST RESTRICTIVE SHALL APPLY 2. WHERE NO CONSTRUCTION DETAILS ARE SHOWN OR NOTED FOR ANY PART OF THE WORK TO BE DONE THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 3. THE CONTRACTOR SHALL DETERMINE THE LOCATION OF ALL UTILITY SERVICES IN THE AREA TO BE EXCAVATED (ABOVE AND BELOW GRADE) PRIOR TO COMMENCING THE WORK TO BE DONE. 4. SHOULD ANY LOOSE FILL / EXPANSIVE SOIL / GROUND WATER OR OTHER DANGEROUS CONDITIONS BE ENCOUNTERED DURING SITE EXCAVATION THE GENERAL CONTRACTOR, OWNER AND ENGINEER SHALL BE NOTIFIED AND ALL WORK SHALL CEASE IMMEDIATELY. 5. SMOKE AND CARBON MONOXIDE DETECTORS ARE REQUIRED IN THE HALL/AREA SERVICING EACH SLEEPING AREA. BATTERY OPERATED DETECTORS ARE ACCEPTABLE FOR EXISTING CONSTRUCTION. 6. INTERIOR WALLS AND CEILING FINISH FLAME SPREAD RATING SHALL CONFORM TO THE REQUIREMENTS OF LOCAL CODES, ORDINANCE, RULES AND REGULATIONS. 7. THE CONSTRUCTION, REMODEL, OR DEMOLITION OF BUILDING SHALL COMPLY WITH REQUIRED CODE. 8. THE CONTRACTOR, BEFORE COMMENCING WORK, SHALL NOTIFY THE OWNER IN WRITING OF ANY WORK CANNOT BE FULLY GUARANTEED OR EXECUTED WITHIN THE INTENT OF THE DRAWINGS PRIOR TO BID SUBMITTAL. 9. ALL CONSTRUCTION SHALL BE IN STRICT CONFORMANCE WITH MANUFACTURERS' SPECIFICATIONS. ALL DISCREPANCIES BETWEEN THESE SPECIFICATIONS AND THE CONTRACT DOCUMENTS PREPARED BY PLAN AND PERMIT INC. AND HIS CONSULTANTS SHALL BE BROUGHT TO THE ATTENTION OF DESIGNER IN WRITING BEFORE COMMENCING WORK. 10.REFERENCE TO PRODUCT MANUFACTURER OR TRADE NAMES ARE FOR MINIMUM PERFORMANCE SPECIFICATION ONLY. SUBMITTAL EQUALS MAY BE ALLOWED UPON APPROVAL BY PLAN AND PERMIT INC.. MATERIAL SUBSTITUTIONS MADE BY THE CONTRACTOR WITHOUT WRITTEN APPROVAL BY PLAN AND PERMIT INC. SHALL NOT BE RESPONSIBILITY OR OF RELATED MATERIALS AND DETAILS. 11.CUTTING AND PATCHING INCLUDES CUTTING INTO EXISTING CONSTRUCTION TO PROVIDE FOR INSTALLATION OR PERFORMANCE OF OTHER WORK AND SUBSEQUENT FITTING AND PATCHING REQUIRED TO RESTORE SURFACES TO THEIR ORIGINAL CONDITION. USE MATERIALS FOR CUTTING AND PATCHING IDENTICAL TO EXISTING MATERIALS. 12.DO NOT CUT AND PATCH STRUCTURAL WORK IN A MANNER THAT WOULD RESULT IN A REDUCTION OF CARRYING CAPACITY OR LOAD-DEFLECTION RATIO. SUBMIT PROPOSAL AND OBTAIN ENGINEER'S APPROVAL BEFORE PROCEEDING WITH CUT AND PATCH OF STRUCTURAL WORK. 13.ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN ON THE PLANS. DIMENSIONS ARE TO FACE OF STUDS, FACE OF FOUNDATION, FACE OF CONCRETE BLOCK TOP OF SLAB, OR CENTER OF OPENINGS, U.N.O .. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL VERIFY DIMENSIONS AND REVIEW ANY CONFLICTS OR DISCREPANCIES WITH PLAN AND PERMIT INC. PRIOR TO COMMENCEMENT OF WORK. 14.THE ARCHITECTURAL SITE PLAN IS NOT A SURVEY. IT IS BASED ON SITE INFORMATION PROVIDED BY THE OWNER FOR BUILDING DEPARTMENT REFERENCE ONLY. ON-SITE VERIFICATION OF ALL DIMENSIONS, ALL EXISTING CONDITIONS, GROUND WATER, EXISTING IMPROVEMENTS, PROPERTY LINES, EASEMENTS, SETBACKS, EXISTING UTILITIES AND SUBSTRUCTURES IS THE RESPONSIBILITY OF THE CONTRACTOR. 15.ONLY NOTED DIMENSIONS ARE TO BE USED FOR CONSTRUCTION PURPOSES. DO NOT SCALE DRAWINGS. OBTAIN CLARIFICATION OF DIMENSIONS FROM DESIGNER WHEN NECESSARY. ERRORS CAUSED BY SCALED DIMENSIONS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS OWN EXPENSE. 16.MAINTAIN ON THE JOB SITE, IN GOOD ORDER, ONE COPY OF ALL PLANS AND MODIFICATIONS THERETO, (AS-BUILT) FIELD TEST RECORDS AND INSPECTION REPORTS, CORRESPONDENCE PERTAINING TO THE WORK ON SITE AND PERMITS, AND PERMITS, AND PERMIT SETS OF PLANS FOR THE USE OF BUILDING OFFICIALS. FIRE DEPARTMENT NOTES 1. THE CONTRACTOR SHALL PROVIDE HIGH PERFORMANCE FIRE STOP SYSTEM AT ALL FIRE RATED PENETRATION INSTALLED PER MANUFACTURE'S LATEST INSTALLATION SPECIFICATION. 2. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE CONSTRUCTED SO AS TO MAINTAIN AN EQUAL OR GREATER FIRE RATING. 3. BUILDINGS UNDERGOING CONSTRUCTION, ALTERATION OR DEMOLITION SHALL BE IN ACCORDANCE WITH CFC ARTICLE 87. [CFC 8701] 4. ADDRESS SHALL BE PROVIDED FOR ALL NEW AND EXISTING BUILDINGS IN A POSITION AS TO BE PLAINLY SEEN VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY [CFC 901.4.4, FHPS POLICY P-00-6] 5. DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME-RETARDANT CONDITION. [CALIF. CODE OF REGS., TITLE 19, 3.08, 3.21, CEC 2501.5] 6. CONTRACTOR SHALL CONTACT THE COUNTY FIRE AUTHORITY FOR AN INSPECTION UPON COMPLETION OF WORK. CONTRACTORS NOTES DOUBLE MICROWAVE AND WARMING & @ ° Ø % # (E) (N) AA A/C AND AT DEGREES DIAMETER PERCENT POUND OR NUMBER EXISTING NEW ATTIC ACCESS AIR CONDITIONING AD AL APN ARCH AWG BBQ BLDG BTU CAB CLG CMU CONC AREA DRAIN ALUMINUM ASSESSORS PARCEL NUMBER ARCHITECT AWNING BARBEQUE BUILDING BRITISH THERMAL UNIT CABINET CEILING CONCRETE MASONRY UNIT CONCRETE CSMT CASEMENT DEMO DIA DIM DS DV D/W ELEC M DIAMETER DIMENSION DOWNSPOUT DRYER VENT DISHWASHER ELECTRICAL ELECTRICAL METER FAU FD FF FGR FLR FP FR FT FTG FXD GAL GB GI GL G GWB GYP HB HDR FORCED AIR UNIT FLOOR DRAIN FINISH FLOOR FINISH GRADE FLOOR FIREPLACE FIRE RATED FOOT/FEET FOOTING FIXED GALLON GYPSUM BOARD GALVANIZED IRON GLASS GAS METER GYPSUM WALL BOARD GYPSUM HOSE BIBB HEADER HR HT INSUL IN KIT MAX MECH HOUR HEIGHT INSULATION INCH KITCHEN MAXIMUM MECHANICAL MFR MIN MTL MW N/A MANUFACTURER MINIMUM METAL MICROWAVE NOT APPLICABLE PL P/L PLY RA RD REF REV SA SEC SF SFD SH SPEC SQ PLATE PROPERTY LINE PLYWOOD RETURN AIR ROOF DRAIN REFRIGERATOR REVISION SUPPLY AIR SECTION SQUARE FEET SINGLE FAMILY DWELLING SINGLE HUNG SPECIFICATIONS SQUARE STR STRG SYSB T TG STRUCTURAL STORAGE SIDE YARD SETBACK THERMOSTAT TEMPERED GLASS TV TYP TWH U/ U/C VIF W/ TELEVISION TYPICAL TANKLESS WATER HEATER UNDER UNDER COUNTER VERIFY IN FIELD WITH WH WATER HEATER W.I.C W&D WALK - IN CLOSET WASHER AND DRYER DEMOLITION SL SLIDING DWY DRIVEWAY CTDL CATHEDRAL SLPD SLOPED D/MWO DOUBLE OVEN AND MICROWAVE WSOFT WATER SOFTENER CRAWL SPACE ACCESSCA W WATER METER REQ REQUIRED CALCULATIONCALC ADU ACCESSORY DWELLING UNIT D/M&O           1011 W Second St 5/1/2025 PCPC E E E E E E E E E E E E E E E E E E PC E E E E E E E E E E E E E E E E E E E E (N) GARAGE 8' CLG U-1 GARCIA RESIDENCE SHEET PROPERTY OWNER: JUAN GARCIA (949) 627-2074 REV DATE DESCRIPTION 10/16/23A THERE SHALL BE NO CHANGES OR DEVIATION ON THESE PLANS WITHOUT THE CONSENT OF P LAN AND PERMIT INC. NOTES AND DETAILS ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS SHOWN OR NOTED ON TH E DRAWINGS, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK.CONTRAC TOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS A ND FIELD CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY TO PLAN AND PERMIT INC ANY DISCREPANC IES IN WRITING PRIOR TO THE COMMENCEMENT OF ANY WORK OR BE RESPONSIBLE FOR SAME. TH E S E D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F P L A N A N D P E R M I T I N C A N D S H A L L N O T B E U S E D I N C O N N E CT I O N W I T H A N Y O T H E R W O R K E X C E P T B Y A G R E E M E N T W I T H P L A N A N D P E R M I T I N C . B Y U S I N G T H E S E P L A N S , T H E U S E R A G R E E S T O R E L E A S E P L A N A ND P E R M I T I N C F R O M A N Y A N D A L L C L A I M S , L I A B I L I T I E S , S U I T S , A N D D E M A N D S O N A C C O U N T O F A N Y I N J U R Y , D A M A G E O R L O S S O R P E R S O N S O R P RO P E R T Y , I N C L U D I N G I N J U R Y O R D E A T H , O R E C O N O M I C L O S S E S , A R I S I N G O U T O F T H E U S E O F T H E S E P L A N S . SKETCH FOR REVIEW 11/17/23 B 90PD FOR APPROVALC 01/02/240 100PD FOR SUBMITTAL 10/31/23 90PD FOR REVIEW PROPERTY ADDRESS: 1011 W 2ND ST, SANTA ANA, CA 92703 PLAN AND PERMIT INC. ARCHITECTURAL DESIGN SERVICES 9891 IRVINE CENTER DR #200 IRVINE, CA 92618 (714)-715-0923 biz@planandpermit.com LOCATION QR CODE: STATE OF CAL IFORNIAEXP. DATE L I C E NS E D A R CHI T E C T C - 34643 06/30/2025 SIGNATURE PAUL SAN GEMINO 1 UTILITY PLAN & DETAILS 04' 4'8' 1 4" = 1'-0" FIRE SPRINKLER TANK WATER HEATER STEP LIGHTS= COLD WATER HOT WATER DIRECT WASTE3 4" GAS PIPE WATER PIPE UTILITY LEGEND: TELEPHONE TV TV BUZZER UNDER CABINET LIGHTING UTILITY POLE. POWER POINT OF CONNECTION CEILING FAN WITH LED LIGHT OUTDOOR RECESSED LIGHT FOR WALLS SEWER PIPE ELECTRICAL ROUTE = = RECESSED LED LIGHT DUCTED ENERGY STAR COMPLIANT EXHAUST FAN WITH HUMIDITY SENSOR AND LED LIGHT. MIN 50 CFM. OUTDOOR HIGH EFFICIENCY LED LIGHT W/ PHOTOCELL AND MOTION SENSOR INDOOR WALL MOUNTED LED LIGHT PCSWITCH WITH DIMMER ELECTRICAL METERCHANDELIER VENTILATION DUCT CARBON MONOXIDE ALARM AND SEALED BATTERY PHOTO ELECTRIC SMOKE DETECTOR WITH IONIZATION SENSOR = = = = = = = = = = = = = = = HOSE BIB DOWNSPOUT RETURN AIR WALL REGISTER THERMOSTAT =WATER METER = S = = = = G GAS METER TRACK LIGHT FIXTURE W E = = = = = = = = HB WEATHER PROOF SWITCHWP 3 THREE WAY SWITCH WITH DIMMER PENDANT LIGHT TANKLESS WATER HEATER = = DUCTED ENERGY STAR COMPLIANT EXHAUST FAN WITH HUMIDITY SENSOR . MIN 50 CFM. =WEATHER PROOF DUPLEX TAMPER- RESISTANT AFCI/GFCI RECEPTACLE DUPLEX TAMPER-RESISTANT AFCI RECEPTACLE 240V RECEPTACLE DUPLEX TAMPER-RESISTANT AFCI/GFCI RECEPTACLE WP = = = = DS= = = = = = = = SHOWER HEAD RETURN AIR CEILING REGISTER LINEAR SHOWER DRAIN SUPPLY AIR CEILING REGISTER FG FUEL GAS CW COLD WATER VALVE SUPPLY AIR WALL REGISTER ATTIC MOUNTED FORCED AIR UNIT=ATTIC FAU FORCED AIR HEATING UNIT=A/C AIR CONDITIONING= SPLIT SYSTEM EXTERIOR UNIT WALL MOUNT SPLIT INTERIOR UNIT = = H P U H P U =WATER SOFTENER = = = = = = = = RETURN AIR FLOOR REGISTER= = SMOKE ALARM SEALED BATTERY PHOTOELECTRIC SMOKE DETECTOR WITH IONIZATION SENSOR, INTERCONNECTED AND HARD-WIRED,(UL 217). CARBON MONOXIDE ALARM SEALED BATTERY PHOTOELECTRIC, INTERCONNECTED AND HARD-WIRED,(UL 2034). VS VACANCY SENSOR SWITCH F A U GARAGE ELECTRICAL PLAN FIRE BARRIER NOTE: SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH U.L. LISTED (UL1479 OR ASTM E814) AND FIRE CODE APPROVED FIRE BARRIER SEALANT. (3M FIRE BARRIER SEALANT CP 25WB+ , OR APPROVED EQUAL). ELECTRICAL NOTES: 1. PROVIDE A MINIMUM OF 1-20 AMP CIRCUIT FOR BATHROOM(S) OUTLET. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ON BATHROOM. 2. PROVIDE A MINIMUM OF 1-20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. 3. PROVIDE A MINIMUM OF 2-20 AMP SMALL APPLIANCE CIRCUIT FOR THE KITCHEN COUNTER TOP. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE BALANCED. 4. PROVIDE DEDICATED CIRCUITS FOR MICROWAVE AND ELECTRIC OVEN. 5. ELECTRICAL CONDUCTORS USED TO CARRY CURRENT SHALL BE COPPER UNLESS OTHERWISE PROVIDED IN THE ELECTRICAL CODE. CEC 110.5 29. 6. OCCUPANCY SENSORS MUST HAVE NO MANUAL OVERRIDE, 20 MIN MAXIMUM TIMER. 7. UNDER CABINET LIGHTING SHALL BE CONTROLLED SEPARATELY FROM CEILING LIGHTING. 8. ALL ENCLOSED LUMINARIES SHALL BE MARKED WITH JA8-2019-E (CENC 150.0(K)(1)(H)). 9. ALL RECESSED DOWNLIGHTS IN CEILINGS SHALL COMPLY WITH CALIFORNIA ENERGY CODE SECTION (CENC 150.0(K)(1)(C)). 10. ALL INSTALLED LUMINARIES SHALL BE HIGH EFFICIENCY IN ACCORDANCE WITH TABLE 150.0A PER CENC SECTION 150.0(K)(A) 11. ALL RECESSED DOWNLIGHTS IN CEILINGS SHALL MEET THE FOLLOWING REQUIREMENTS: 11.1. SHALL BE LISTED AS ZERO CLEARANCE INSULATION CONTACT (IC) BY UNDERWRITERS LABORATORIES OR OTHER NATIONALLY TESTING/RATING LABORATORY. 11.2. HAVE A LABEL THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WITH AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS WHEN TESTED IN ACCORDANCE WITH ASTM E283. 11.3. BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINAIRE HOUSING AND CEILING, AND SHALL HAVE ALL AIR LEAK PATHS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SEALED WITH A GASKET OR CAULK. 11.4. ALLOW BALLAST OR DRIVER MAINTENANCE AND REPLACEMENT TO BE READILY ACCESSIBLE TO BUILDING OCCUPANTS FROM BELOW THE CEILING WITHOUT REQUIRING THE CUTTING OF HOLES IN THE CEILING. 11.5. SHALL NOT CONTAIN SCREW BASED SOCKETS. 11.6. SHALL CONTAIN LIGHT SOURCES THAT COMPLY WITH REFERENCES JOINT APPENDIX 8 (JA8), INCLUDING THE ELEVATED TEMPERATURE REQUIREMENTS, AND THAT ARE MARKED "JA8-2019-E" AS SPECIFIEDIN REFERENCE JA8. 12. FOR FIRE-RESISTIVE WALLS, RECESSED FIXTURES SHALL BE INSTALLED SO THAT THE REQUIRED FIRE-RESISTANCE RATING WILL NOT BE REDUCED. 13. RECEPTACLE HEIGHTS: ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN 48 INCHES (1219 MM) MEASURED FROM THE TOP OF THE RECEPTACLE OUTLET BOX NOR LESS THAN 15 INCHES (381 MM) MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX TO THE LEVEL OF THE FINISHED FLOOR OR WORKING PLATFORM. IF THE REACH IS OVER A PHYSICAL BARRIER OR AN OBSTRUCTION (FOR EXAMPLE, A KITCHEN BASE CABINET), RECEPTACLES SHALL BE LOCATED WITHIN THE REACH RANGES SPECIFIED IN SECTION 1138A.3. PHYSICAL BARRIERS AND OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25 INCHES (635 MM) FROM THE WALL BENEATH THE RECEPTACLE. COUNTERTOPS SHALL BE ALLOWED TO EXTEND 251/2 INCHES (647.7 MM) FROM THE WALL BENEATH THE RECEPTACLE.RECEPTACLE OUTLETS THAT DO NOT SATISFY THESE SPECIFICATIONS ARE ACCEPTABLE PROVIDED THAT COMPARABLE RECEPTACLE OUTLETS, THAT PERFORM THE SAME FUNCTIONS, ARE PROVIDED WITHIN THE SAME AREA AND ARE ACCESSIBLE. EXCEPTIONS: a. RECEPTACLE OUTLETS INSTALLED AS PART OF PERMANENTLY INSTALLED BASEBOARD HEATERS ARE EXEMPT. b. REQUIRED RECEPTACLE OUTLETS SHALL BE PERMITTED IN FLOORS WHEN ADJACENT TO SLIDING PANELS OR WALLS. c. BASEBOARD ELECTRICAL OUTLETS USED IN RELOCATABLE PARTITIONS, WINDOW WALLS OR OTHER ELECTRICAL CONVENIENCE FLOOR OUTLETS ARE NOT SUBJECT TO THE MINIMUM HEIGHT REQUIREMENTS. d. THIS SECTION SHALL NOT APPLY TO EXISTING BUILDINGS WHEN THE ENFORCING AGENCY DETERMINES THAT COMPLIANCE WITH THESE STANDARDS WOULD CREATE AN UNREASONABLE HARDSHIP. 14. SWITCH AND CONTROL HEIGHTS: CONTROLS OR SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, ALARMS OR COOLING, HEATING AND VENTILATING EQUIPMENT SHALL BE LOCATED NO MORE THAN 48 INCHES (1219 MM) MEASURED FROM THE TOP OF THE OUTLET BOX NOR LESS THAN 15 INCHES (381 MM) MEASURED FROM THE BOTTOM OF THE OUTLET BOX TO THE LEVEL OF THE FINISHED FLOOR OR WORKING PLATFORM. IF THE REACH IS OVER A PHYSICAL BARRIER OR AN OBSTRUCTION (FOR EXAMPLE, A KITCHEN BASE CABINET) SWITCHES AND CONTROLS SHALL BE LOCATED WITHIN THE REACH RANGES SPECIFIED IN SECTION 1138A.3. PHYSICAL BARRIERS OR OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25 INCHES (635 MM) FROM THE WALL BENEATH A CONTROL OR SWITCH. COUNTERTOPS SHALL BE ALLOWED TO EXTEND 251/2 INCHES (647.7 MM) FROM THE WALL BENEATH A CONTROL OR SWITCH. SWITCHES AND CONTROLS THAT DO NOT SATISFY THESE SPECIFICATIONS ARE ACCEPTABLE PROVIDED THAT COMPARABLE CONTROLS OR OUTLETS, THAT PERFORM THE SAME FUNCTIONS, ARE PROVIDED WITHIN THE SAME AREA AND ARE ACCESSIBLE. 15. EXCEPTION: APPLIANCES (E.G., KITCHEN STOVES, DISHWASHERS, RANGE HOODS, MICROWAVE OVENS AND SIMILAR APPLIANCES) WHICH HAVE CONTROLS LOCATED ON THE APPLIANCE. PLUMBING NOTES: 1. PLUMBING SHOWN IS FOR LOCATION ONLY 2. PLUMBER TO VERIFY LOCATION OF SEWER AND WATER LOCATIONS SHOWN 3. PLUMBING FIXTURE SHALL COMPLY WITH 4.303.1. 4. DOMESTIC HOT WATER SHALL BE INSULATED. PIPE INSULATION SHALL HAVE A MINIMUM WALL THICKNESS OF NOT LESS THAN THE DIAMETER OF THE PIPE OR Ø2". 5. WATER CLOSET SHALL HAVE 15" TO ANY WALL OR OBSTRUCTION ON EACH SIDE OF ITS CENTERLINE AND 24" CLEAR SPACE IN FRONT. 6. SHOWER THRESHOLD SHALL BE NO LESS THAN 2 INCHES ABOVE THE SHOWER DRAIN. 7. SHOWER SHALL BE PROVIDED WITH MIXING VALVE THAT WILL PROVIDE SCALD AND THERMAL SHOCK PROTECTION IN ACCORDANCE WITH ASSE 1016 OR ASME A112.18.1/CSA B125.1. (CPC 408.3) 8. ALL ROOF DRAINAGE SHALL BE PIPED IN A CLOSED PIPE SYSTEM TO STREET OR APPROVED FACILITY (U.N.O.) 9. ALL SEWER PIPES SHALL BE 4" MIN. DIAMETER UNDERGROUND AND TOILET; 1 1/2" DIAMETER FOR BASIN, BATH AND VENT PIPES - VERIFY SIZE AND MATERIAL TO COMPLY WITH ALL STATE AND LOCAL CODES. 10. STANDARDS FOR PLUMBING FIXTURES AND FITTINGS. PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE, AND SHALL MEET THE APPLICABLE STANDARDS REFERENCED IN TABLE 1701.1OF THE CALIFORNIA PLUMBING CODE. NOTE: THIS TABLE COMPILES THE DATA IN SECTION , 4.303.1AND IS INCLUDED AS A CONVENIENCE FOR THE USER. 11. FOUR OR MORE WATER CLOSET FIXTURE UNITS WILL REQUIRE A MINIMUM 4” SANITARY SEWER DRAIN BEGINNING AT THE WATER CLOSET AND RUNNING TO THE SEWER MAIN IN THE STREET. CONTRACTOR SHALL VERIFY EXISTING SANITARY SEWER LATERAL MEETS CAPACITY (REF: 2019 CPC 703.2 AND TABLE 703.2). WHERE DRAIN IS UNDERSIZED, CONTACTOR SHALL UPGRADE MAIN SANITARY SEWER DRAIN TO BE 4” MINIMUM DIAMETER”. MECHANICAL NOTES: 1. BATHROOM AND EXHAUST FAN(S) SHALL BE OF THE FOLLOWING . 1.1. ENERGY STAR COMPLIANT 1.2. BE DUCTED TO TERMINATE OUTSIDE THE BUILDING. 1.3. BE RATED FOR SOUND AT A MAXIMUM OF 3 SONE. 2. KITCHEN HOOD FAN FLOW OF 100 C.F.M. KITCHEN RANGE HOODS SHALL BE INSTALLED FOR COOKING FACILITIES WITH AN APPROVED FORCED-DRAFT SYSTEM OF VENTILATION VENTED TO THE OUTSIDE OF THE BUILDING. DUCTS USED FOR DOMESTIC KITCHEN RANGE VENTILATION SHALL BE OF METAL, OR OTHER APPROVED MATERIAL, AND SHALL HAVE SMOOTH INTERIOR SURFACES. DUCTS FOR DOMESTIC RANGE HOODS SHALL ONLY SERVE COOKING APPLIANCES. (CMC 504.3; SCMC 15.16.020) 3. MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED A MINIMUM OF 10 FEET FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT SUCH AS VENTS, CHIMNEYS, AND PLUMBING VENTS. WHERE A SOURCE OF CONTAMINANT IS LOCATED WITHIN 10 FEET OF AN INTAKE OPENING, SUCH OPENING SHALL BE LOCATED A MINIMUM OF 3 FEET BELOW THE CONTAMINANT SOURCE. R303.5.1. SMOKE ALARMS CARBON MONOXIDE ALARMS NOTE: 1. THE SMOKE ALARMS SHALL BE INTERCONNECTED AND HARD-WIRED.(UL 217) 2. CARBON MONOXIDE ALARM SHALL BE INTERCONNECTED HARD-WIRED WITH BATTERY BACKUP.(UL 2034) TABLE - MAXIMUM FIXTURE WATER USE FIXTURE TYPE FLOW RATE SHOWER HEADS (RESIDENTIAL)1.8 GMP @ 80 PSI LAVATORY FAUCETS (RESIDENTIAL)MAX. 1.2 GPM @ 60 PSI, MIN. 0.8 GPM @ 20 PSI LAVATORY FAUCETS IN COMMON & PUBLIC USE AREAS 0.5 GPM @ 60 PSI KITCHEN FAUCETS 1.8 GPM @ 60 PSI METERING FAUCETS 0.2 GAL/CYCLE WATER CLOSET 1.28 GAL/FLUSH URINALS 0.125 GAL/FLUSH FIXTURE TYPE FLOW RATE H P U =CEILING SPLIT INTERIOR UNIT GARAGE DOOR OPENER RECEPTACLE IN CEILING W/ BACKUP BATTERY, AUTOMATIC GARAGE DOOR OPENERS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 325.TYP. 3 WET RATED RECESSED LED LIGHT(OR APPROVED EQUAL) RAIN GUTTER AND INSTALLATION2 N.T.S. N.T.S.           1011 W Second St 5/1/2025 South Coast Air Quality Management District 21865 Copley Drive, Diamond Bar, CA 91765­4182 Phone: (909) 396­2336 www.aqmd.gov Facility ID 95762 Notification Number 831328 Rule 1403 Notification of Routine Demolition Please maintain a copy of this Notification at the job site, either electronic or paper. Project Type Project Type Demolition Project Urgency Routine Origin Date 3/13/2025 12:00:00 AM Completed By Juan C. Garcia Contact Phone (714)604­9396 Contact Email juangarcia30014@yahoo.com User Email awang2@aqmd.gov Contractor Information Company Name RESIDENTIAL ASBESTOS Address 21865 COPLEY DR City DIAMOND BAR State CA Zip 91765 CSLB License #000000 OSHA REG # Supervisor #1 Juan C. Garcia Phone (714) 604­9396 Site Information Site Name Primary home Juan C. Garcia Project #Homeowner Filling Site Street #1011 Street Name W 2ND ST Cross Street OLIVE Site County ORANGE City SANTA ANA State CA Zip 92703 Contact Name Juan C Garcia Contact Phone (714)604­9396 Site Owner Juan C Garcia Owner Address 1011 W 2ND ST City SANTA ANA State CA Zip 92703 Project Start Date 3/28/2025 Project End Date 4/3/2025 Project Work Shift(s)Day Building Size in Sq.ft 1008 Number of Floors 1 Building Age (years)50 Number of Building/Dwelling Units 1 Building Prior Use House Asbestos Survey Yes Asbestos Found No Asbestos Removed NA Building to be Demolished No Describe Work Demolition 4 ways for detached garage then rebuilder new one Describe Work Location Behind House Project Information Demolition Information All Asbestos containing materials must be removed prior to any demolition activity Survey Information 1011 W Second St 5/1/2025 Certified Asbestos Inspector Name Michael S Jackson Certification Expiration Date​7/15/2025 12:00:00 AM Survey Plan Date 1/24/2025 12:00:00 AM Phone Number (949)230­9779 EMail mjacksonenvironmental@gmail.com Size of Demolition Project in sq. ft 400 Work Practices at Demolition Site Spray Water , Exit Grates , Tarp Trucks/Bins Contingency Demolition plan Stop Work , Isolate Work Area , Notify Owner , Stabilize , Secure , Characterize Waste , Survey Waste Information Waste Transporter Juan C Garcia Address 1011 W 2nd St City SANTA ANA State CA Zip 92703   Landfill Frank R Bowerman Address 11002 Bee Cayon Access Rd City Irvine State CA Zip 92602 Fee Payment Size of Demolition Project in sq. ft 400 Tracking Number 0 Project Size Fee 79.23 Additional Fee 0 Total Fee $ 79.23 Payment Made $ 79.23 Balance Due $ 0 1011 W Second St 5/1/2025  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 Project No: 20231095 Date: 11/15/2024 1011 W 2nd 1011 W 2nd ST, Santa Ana, CA 297030 Project Engineer: M. Jalalpour Approved by: F. Rezaeian Page 1 of 108 11/19/2024 EXP. 06-30-2026 1011 W Second St 5/1/2025 Table of Contents  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 Table of Contents 1 Description of the Structure and Site ......................................................................................................... 3 2 Design Criteria ........................................................................................................................................... 3 2.1 Design Codes and Standards ......................................................................................................... 3 3 Loading ...................................................................................................................................................... 4 3.1 Gravity Loading ............................................................................................................................ 4 3.1.1 Dead Load ............................................................................................................................ 4 3.1.2 Live Load ............................................................................................................................. 5 3.2 Lateral Load .................................................................................................................................. 5 3.2.1 Seismic Load ........................................................................................................................ 5 3.2.2 Wind Load ............................................................................................................................ 7 4 Wood Design ............................................................................................................................................. 8 4.1 Shear Wall Design ........................................................................................................................ 8 4.2 Diaphragm Design ...................................................................................................................... 10 4.2.1 Diaphragm Seismic Force .................................................................................................. 10 4.2.2 Collector Design................................................................................................................. 10 4.2.3 Chord Design ..................................................................................................................... 12 4.3 Beam and Post Design ................................................................................................................ 13 4.4 Header, Jack Stud and King Stud Design ................................................................................... 13 4.5 Joist Design ................................................................................................................................. 13 4.6 Stud Wall Design ........................................................................................................................ 13 5 Foundation Design ................................................................................................................................... 14 Appendix A : Orange County ........................................................................................................ 17 Appendix B : ASCE 7 Hazard Report ........................................................................................... 21 Appendix C : Wind Load .............................................................................................................. 25 Appendix D : Shear Wall Design .................................................................................................. 36 Appendix E : Beam and Post Design ............................................................................................ 60 Appendix F : Header, Jack Stud and King Stud Design ............................................................... 70 Appendix G : Joist Design ............................................................................................................. 79 Appendix H : Stud Wall Design .................................................................................................... 82 Appendix I : Foundation Design .................................................................................................. 84 Page 2 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 2 1 Description of the Structure and Site This project is located at 1011 W 2nd ST, Santa Ana, CA 297030, is a demolishing and rebuilding project. The proposed south elevation of structure is shown in Fig.1. The structural system consists of wood structural frame system with shear wall. Figure 1. The Proposed South Elevation of Structure No geotechnical report was provided. The design of foundation is based on the default value provided in foundation requirements for residential projects and accessory structures dated 06/22/2020 by the county of orange department of public works. The design of foundation is also based on the default values provided in table 1806.2 of CBC 2022 for soil class 5 (cl, ml, mh and ch). For more information, see Appendix A. 2 Design Criteria 2.1 Design Codes and Standards For design purposes, the following codes, standards, and local regulations are used:  California Building Standards Code, (CBC-2022)  Minimum Design Loads for Buildings and Other Structures, (ASCE/SEI 7-16)  Building Code Requirements for Structural Concrete and Commentary, (ACI318–19)  National Design Specification for Wood Construction, (NDS-2018)  Special Design Provisions for Wind and Seismic, (SDPWS-2021) Page 3 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 3 3 Loading 3.1 Gravity Loading 3.1.1 Dead Load The dead loads are tabulated in Table 1. Table 1. Dead Loads Name Value Unit Ceiling 8 psf Roof 12 psf Exterior Wall 16 psf 3.1.2 Live Load Live loads are tabulated in Table 2. Table 2. Live Loads Name Value Unit Roof 20 psf Ceiling 10 psf Partition 10 psf Page 4 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 4 3.2 Lateral Load ASCE 7 hazard report is given in Appendix B. 3.2.1 Seismic Load The wood seismic parameters are tabulated in Table 3. Table 3. Seismic Parameters S1 0.462 Mapped acceleration parameters Ss 1.295 TL 8 Site Class D(Default) Occupancy Category II Height of Building (feet) 10 Importance Factor (Ie) 1 Overstrength Factor, Ω0 3 Table 12.2-1 Deflection Amplification Factor, Cd 4 Table 12.2-1 Response Modification Coefficient 6.5 Table 12.2-1 Building Period Parameter Ct 0.02 Table 12.8-2 Building Period Parameter x 0.75 Table 12.8-2 Site Coefficient at Short Period (Fa) 1.2 (Table 11.4-1) Site Coefficient at 1 Sec Period (Fv) 1.838 (Table 11.4-2) Ta 0.112 Section 12.8.2 SMS 1.554 Section 11.4.4, Eq. (11.4-1) SM1 0.849156 Section 11.4.4, Eq. (11.4-2) SDS 1.036 Section 11.4.5, Eq. (11.4-3) SD1 0.566 Section 11.4.5, Eq. (11.4-4) T0 0.109 Section 11.4.6 Ts 0.546 Section 11.4.6 Seismic Design Category Based on Short-Period Response Acceleration Parameter D Table 11.6.1 Seismic Design Category Based on 1-s Period Response Acceleration Parameter D Table 11.6.2 Cs 0.159 Eq. (12.8-2). Cs 1.166 Eq. (12.8-3) & Eq. (12.8-4) Cs(min) 0.046 Eq. (12.8-5). Cs(min) 0 Eq. (12.8-6). Seismic Response Coefficient Cs 0.159 Page 5 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 5 Design response spectrum is tabulated in Table 4 and it is shown in Fig.2. Table 4. Design Response Spectrum Figure 2. Design Response Spectrum 3.2.1.2 Effective Seismic Weight The effective seismic weight is tabulated in Table 5. Table 5. The Effective Seismic Weight Weight of Roof Area Roof Area 590 sf Roof Dead Load 12 psf Roof Weight 7080 lb Weight of Ceiling Area Ceiling Area 401.2 sf Ceiling Dead Load 8 psf Ceiling Weight 3209 lb Wall Weight Exterior Wall Length 397 feet Exterior Wall Dead Load 16 psf Partition Area 200.6 sf Partition Dead Load 10 psf Total Weight 2965 lb 0 0.5 1 1.5 0 2 4 6 8 10Sp e c t r a l R e s p o n s e Ac c e l e r a t i o n , S a ( g ) Period, T (sec) Design Response Spectrum0 0.4144 0.109 1.036 0.819 1.036 1.22 0.696 2.14 0.397 2.85 0.298 4.27 0.199 8 0.071 8.5 0.063 Page 6 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 6 3.2.1.3 Base Shear The base shear is calculated according to the following equations: Cs = 0.159 Seismic Weight = 18647 lb Base Shear = Cs × W = 0.159 × 18647 = 2965 lb = 2.965 kips 3.2.1.4 Horizontal Distribution of Seismic Load Horizontal distribution of seismic load is tabulated in Table 6. Table 6. Horizontal Distribution of Seismic Load Line Tributary Area Total Area Tributary Area / Total Area Seismic Shear Force Shear Line Force ρF 0.7×ρF sft sft - lb lb lb lb A 295 590 0.5 2965 1483 1928 1349.6 B 1 2 3.2.2 Wind Load The wind load is given in Appendix C. 3.2.2.1 Horizontal Distribution of Wind Load Horizontal distribution of wind load is tabulated in Table 6. Table 7. Horizontal Distribution of wind Load Line Tributary Area Total Area Tributary Area / Total Area Wind Shear Force Seismic Shear Force Shear Line Force ρF sft sft - lb lb lb A 295 590 0.5 4000 2000 1483 1928 B 1 3400 1700 2 Page 7 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 7 4 Wood Design 4.1 Shear Wall Design Shear wall design is given in Appendix D. The location of shear walls are shown in Fig 3 and 4. Figure 3. The Location of Ceiling Plan Shear Walls SW1 (18'-2") SW 1 (2 1 ' - 1 " ) SW4 (3'-1") 1 2 A B HDU 5C46 SW4 (3'-1") C46 SW 1 (1 7 ' - 8 " ) HDU 5 C46HDU 5 C46HDU 5 HDU 2C44 HDU 2 C44 HDU 2 C44 C44 Page 8 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 8 Figure 4. The Location of Roof Plan Shear Walls C44 1 2 A B C46 C44 SW1 (18'-2") SW 1 (2 1 ' - 1 " ) SW 1 (1 7 ' - 8 " ) C46 C46 C46 C44 Page 9 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 9 4.2 Diaphragm Design 4.2.1 Diaphragm Seismic Force 4.2.1.1 Horizontal Distribution of Diaphragm Seismic Force The horizontal distribution of diaphragm seismic force is tabulated in Table 8. Table 8. Horizontal Distribution of Diaphragm Seismic Force Line Tributary Area Total Area Tributary Area/ Total Area Fp2 Fp (min) Fp (max) Shear Line Forces 0.7×F sft sft - lb lb lb lb lb A 295 590 0.5 2965 3864 7728 1932 1352 B 1 2 4.2.2 Collector Design The location of collector for one and two shear walls are shown in fig 5 and 6. Figure 5. Location of Collector for One Shear Wall Figure 6. Location of Collector for Two Shear Walls Page 10 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 10 The collector force is tabulated in Tables 9 and 10. Table 9. Collector Force for One Shear Wall Line Line Length Shear Line Forces Shear Line Forces Drag Left Drag Right lb plf lb lb 1 22.1 1349.6 61.07 0 -269 Table 10. Collector Force for Two Shear Wall Line Line Length Shear Line Forces Shear Line Forces Shear Wall-1 Forces Shear Wall-2 Forces Drag 2 Drag 3 Drag 4 Drag 5 lb plf lb lb lb lb lb lb B 18.1 1349.6 74.6 674.8 674.8 0 -447 447 0 Page 11 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 11 4.2.3 Chord Design M=wl2/8= 14981.8 ft-lbs T=C= 14981.76 /18.16 = 103.124 lbs W=3864×0.7/22.1=122.4 plf M=wl2/8= 2773.3 ft-lbs T=C= 2773.3 /22.1 = 125.5 lbs lbs W=3864×0.7/18.16= 148.95 plf Page 12 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 12 4.3 Beam and Post Design Beam and post design is given in Appendix E. 4.4 Header, Jack Stud and King Stud Design Header, jack stud and king stud design is given in Appendix F. 4.5 Joist Design Joist design is given in Appendix G. 4.6 Stud Wall Design Stud wall design is given in Appendix H. 2x4 D.F No2 ft=575 psi CD (seismic) = 1.6 CM = 1.0 Ct = 1.0 CF(Ft) = 1.0 Ci=0.8 Ag= 5.25 in2 𝑓𝑡′=𝑓𝑡× 𝐶𝐷× 𝐶𝑀× 𝐶𝑡× 𝐶𝑓× 𝐶𝑖=736 𝑝𝑠𝑖 Ft= 736 psi×5.25 in2 = 3864 lb fc=1350 psi CD (seismic) = 1.6 CM = 1.0 Ct = 1.0 CF(Ft) = 1.0 Ci=0.8 Ag= 5.25 in2 𝑓𝑐′=𝑓𝑐× 𝐶𝐷× 𝐶𝑀× 𝐶𝑡× 𝐶𝑓× 𝐶𝑖× 𝐶=1728 𝑝𝑠𝑖 Fc= 1728 psi×5.25 in2= 9072 lb Page 13 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 13 5 Foundation Design The foundation design is given in Appendix I. Allowable bearing capacity for the design of foundations = 1500 psf The location of elements are shown in Fig 7 and 8. Page 14 of 108 C44 B-1 HDR-1 1 2 A B HD R - 2 C44 C46 C46 CJ-1 C.A . C.A . C44 C5 HD R - 3 C6 C6 C46 C46 C44 Figure 7. The Location of Ceiling Plan Elements 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 14 Page 15 of 108 Figure 8. The Location of Roof Plan Elements RR-1 RR-1 C44 C44 RB - 1 RB - 2 C2 C3 1 2 A B C1 C46 C44 C46 C46 C46 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 15 Limitations SAZAN performed the structural design in a manner consistent with the level of skill and care ordinarily exercised by professional engineers and consultants practicing under similar conditions. No other representation, warranty, or guarantee is given. Provided opinions are based on our engineering judgment. We will not be responsible for latent defects that may appear in the future or for different opinions of others that may arise. The design is performed considering available information for the structure. Should additional information become available that we are not aware of, or which is unknown at the time of our analysis, we reserve the right to revise our design as needed and additional costs may be required. Page 16 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 16 Appendix A : Orange County Page 17 of 108 1011 W Second St 5/1/2025 EFFECTIVE DATE: June 22, 2020 BACKGROUND: 1.Section R401.4 of 2019 California Residential Code (CRC) requires a soils test to determine the soil's characteristics if expansive soils are likely to be present. 2.Section 1803.5.11 of 2019 California Building Code (CBC) requires a "geotechnical investigationH for any structure determined to be in Seismic Design Category C, D, E or Fin accordance with Section 1613. 3.Exception to Section 1803.2 states, "The building official shall be permitted to waive the requirement for a geotechnical investigation where satisfactory data from adjacent areas is available that demonstrates an investigation is not necessary for any of the conditions in Sections 1803.5.1 through 1803.5.6 and Sections 1803.5.10 and 1803.5.11." POLICY: Since majority of the County of Orange is located in Seismic Design Category D and due to the presence of expansive soil in some county areas, we have developed the following policy to' comply with the 2019 CRC and CBC. Geotechnical investigation report is required for all projects except as prescribed below. Exception: L One story room addition(s) to a single family dwelling up to 1,200 square feet of individual areas if it is NOT located in liquefaction area. 2.One story room addition(s) to a single family dwelling up to 500 square feet of individual areas if It � located in liquefaction area. 3.(a) Room addition(s) to a single family dwelling larger than 500 square feet of individual areas but not more than 1,200 square feet located in liquefaction area shall require 4' of overexcavation. (b)Detached accessory structure or single family dwelling larger than 500 square feet but not more than 1,200 square feet located in liquefaction area shall require 4' overexcavation. 4.One story detached accessory structure up to 1,200 square feet located in non-liquefaction area. One story detached accessory structure up to 500 square feet located in liquefaction area. 5.Second story addition above existing first floor within the footprint of existing dwelling. Excepted projects as described in item 5 above shall provide a letter from a California Licensed Geotechnical Engineer or Civil Engineer practicing soil engineering stating the condition of existing foundation and supporting Foundation Requirements for Residential Projects and Accessory Structures Page 18 of 108 1011 W Second St 5/1/2025 subgrade soils and providing foundation recommendations due to the added vertical and lateral loads from the proposed second story addition. Excepted projects as described above item 1 through 4 shall follow the alternate method as outlined below in lieu of geotechnical investigation report provided minimum foundation clearance from slope is maintained based on Section 1808.7 or R403.1.7 or County of Orange Grading Code, whichever is more restrictive: A.For slab on grade construction •Scarify top 12" or recompact 4' overexcavation prior to trenching for the utility and/or foundation. 90% compaction report is required at the time of foundation inspection. Damp proofing, base course and pre-saturation are required. •Provide 5" slab on grade reinforced with #4 at 18" on centers each way over 4" base of ½" or larger clean aggregate with 10 mil vapor retarder in direct contact with concrete. Slab shall be tied-in to continuous 12" wide X 24" (minimum embedment into firm soil) foundation. •Continuous foundation must be reinforced with 2 #5 (or 3 #4) top and bottom. See attached slab on grade foundation detail 'A' for additional information. 8.For raised foundation construction: •Provide continuous foundation with 12" wide X 24" (minimum embedment Into firm soll) around the perimeter of the addition. •Continuous foundation must be reinforced with 2 #5 (or 3 #4) top and bottom. •Provide 18" (minimum embedment) for all interior pier footing. See attached raised floor foundation detail 'B' for additional information. Note: All concrete shall be fc'=4,500 psi (minimum) with type V cement maximum water cement ratio of 0.45. No special Inspection required if concrete truck mix ticket is provided. This policy does not apply to projects that require grading plans and permit per County Grading Code. Approved by: Rya[se,f� Engineering Geologist Hadl Tabatabaee, P.E., CBO, CASp County Building Official 6-15-2020 Foundation Requirements for Residential Projects and Accessory Structures Page 19 of 108 1011 W Second St 5/1/2025 Foundation Details 10 MIL (MIN) POLYETHYLENE Page 20 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 17 Appendix B : ASCE 7 Hazard Report Page 21 of 108 1011 W Second St 5/1/2025 ASCE 7 Hazards Report Address: 1011 W 2nd St Santa Ana, California 92703 Standard:ASCE/SEI 7-16 Latitude:33.746434 Risk Category:II Longitude:-117.878092 Soil Class:D - Default (see Section 11.4.3) Elevation:103.7516088974792 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Mon Dec 11 2023 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 22 of 108 1011 W Second St 5/1/2025 SS : 1.295 S1 : 0.462 F a : 1.2 F v : N/A SMS : 1.554 SM1 : N/A SDS : 1.036 SD1 : N/A T L : 8 PGA : 0.548 PGA M : 0.657 F PGA : 1.2 Ie : 1 C v : 1.359 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Mon Dec 11 2023 Page 23 of 108 1011 W Second St 5/1/2025 The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. Page 24 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 18 Appendix C : Wind Load Page 25 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section Sheet no./rev. 1 Calc. by N.K Date 12/12/2023 Chk'd by Date App'd by Date WIND LOADING In accordance with ASCE7-16 Using the directional design method Tedds calculation version 2.1.13 Building data Type of roof;Gable Length of building;b = 25.08 ft Width of building ;d = 21.17 ft Height to eaves;H = 8.00 ft Pitch of roof;0 = 20.5 deg Mean height;h = 9.98 ft General wind load requirements Basic wind speed;V = 95.0 mph Risk category;II Velocity pressure exponent coef (Table 26.6-1);Kd = 0.85 Ground elevation above sea level;zgl = 0 ft Ground elevation factor ;Ke = exp(-0.0000362  zgl/1ft) = 1.00 Exposure category (cl 26.7.3);B Enclosure classification (cl.26.12);Enclosed buildings Internal pressure coef +ve (Table 26.13-1);GCpi_p = 0.18 Internal pressure coef –ve (Table 26.13-1);GCpi_n = -0.18 Gust effect factor;Gf = 0.85 Minimum design wind loading (cl.27.1.5);pmin_r = 8 lb/ft2 Topography Topography factor not significant;Kzt = 1.0 Velocity pressure equation;q = 0.00256  Kz  Kzt  Kd  V2  1psf/mph2; Velocity pressures table z (ft)Kz (Table 26.10-1)qz (psf) 8.00 0.57 11.19 Page 26 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section Sheet no./rev. 2 Calc. by N.K Date 12/12/2023 Chk'd by Date App'd by Date z (ft)Kz (Table 26.10-1)qz (psf) 9.98 0.57 11.19 11.96 0.57 11.19 Peak velocity pressure for internal pressure Peak velocity pressure – internal (as roof press.);qi = 11.19 psf Pressures and forces Net pressure;p = q  Gf  Cpe - qi  GCpi; Net force;Fw = p  Aref; Roof load case 1 - Wind 0, GC pi 0.18, -cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A (-ve)9.98 -0.38 11.19 -5.62 283.41 -1.59 B (-ve)9.98 -0.60 11.19 -7.72 283.41 -2.19 Total vertical net force ;Fw,v = -3.54 kips Total horizontal net force ;Fw,h = 0.21 kips Walls load case 1 - Wind 0, GC pi 0.18, -cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A 8.00 0.80 11.19 5.60 200.67 1.12 B 9.98 -0.50 11.19 -6.77 200.67 -1.36 C 9.98 -0.70 11.19 -8.68 211.21 -1.83 D 9.98 -0.70 11.19 -8.68 211.21 -1.83 Overall loading Projected vertical plan area of wall;Avert_w_0 = b  H = 200.67 ft2 Projected vertical area of roof ;Avert_r_0 = b  d/2  tan(0) = 99.25 ft2 Minimum overall horizontal loading;Fw,total_min = pmin_w  Avert_w_0 + pmin_r  Avert_r_0 = 4.00 kips Leeward net force;Fl = Fw,wB = -1.4 kips Windward net force ;Fw = Fw,wA = 1.1 kips Overall horizontal loading;Fw,total = max(Fw - Fl + Fw,h, Fw,total_min) = 4.0 kips Roof load case 2 - Wind 0, GC pi -0.18, -0cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A (+ve)9.98 0.04 11.19 2.41 283.41 0.68 B (+ve)9.98 -0.60 11.19 -3.69 283.41 -1.05 Total vertical net force ;Fw,v = -0.34 kips Total horizontal net force ;Fw,h = 0.61 kips Page 27 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section Sheet no./rev. 3 Calc. by N.K Date 12/12/2023 Chk'd by Date App'd by Date Walls load case 2 - Wind 0, GC pi -0.18, -0cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A 8.00 0.80 11.19 9.63 200.67 1.93 B 9.98 -0.50 11.19 -2.74 200.67 -0.55 C 9.98 -0.70 11.19 -4.65 211.21 -0.98 D 9.98 -0.70 11.19 -4.65 211.21 -0.98 Overall loading Projected vertical plan area of wall;Avert_w_0 = b  H = 200.67 ft2 Projected vertical area of roof ;Avert_r_0 = b  d/2  tan(0) = 99.25 ft2 Minimum overall horizontal loading;Fw,total_min = pmin_w  Avert_w_0 + pmin_r  Avert_r_0 = 4.00 kips Leeward net force;Fl = Fw,wB = -0.6 kips Windward net force ;Fw = Fw,wA = 1.9 kips Overall horizontal loading;Fw,total = max(Fw - Fl + Fw,h, Fw,total_min) = 4.0 kips Roof load case 3 - Wind 90, GC pi 0.18, -cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A (-ve)9.98 -0.90 11.19 -10.58 112.75 -1.19 B (-ve)9.98 -0.90 11.19 -10.58 112.75 -1.19 C (-ve)9.98 -0.50 11.19 -6.77 225.49 -1.53 D (-ve)9.98 -0.30 11.19 -4.87 115.84 -0.56 Total vertical net force ;Fw,v = -4.19 kips Total horizontal net force ;Fw,h = 0.00 kips Walls load case 3 - Wind 90, GC pi 0.18, -cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A 11.96 0.80 11.19 5.60 211.24 1.18 B 9.98 -0.46 11.19 -6.42 211.21 -1.36 C 9.98 -0.70 11.19 -8.68 200.67 -1.74 D 9.98 -0.70 11.19 -8.68 200.67 -1.74 Overall loading Projected vertical plan area of wall;Avert_w_90 = d  H + d2  tan(0) / 4 = 211.21 ft2 Projected vertical area of roof ;Avert_r_90 = 0.00 ft2 Minimum overall horizontal loading;Fw,total_min = pmin_w  Avert_w_90 + pmin_r  Avert_r_90 = 3.38 kips Leeward net force;Fl = Fw,wB = -1.4 kips Windward net force ;Fw = Fw,wA = 1.2 kips Overall horizontal loading;Fw,total = max(Fw - Fl + Fw,h, Fw,total_min) = 3.4 kips Page 28 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section Sheet no./rev. 4 Calc. by N.K Date 12/12/2023 Chk'd by Date App'd by Date Roof load case 4 - Wind 90, GC pi -0.18, +cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A (+ve)9.98 -0.18 11.19 0.30 112.75 0.03 B (+ve)9.98 -0.18 11.19 0.30 112.75 0.03 C (+ve)9.98 -0.18 11.19 0.30 225.49 0.07 D (+ve)9.98 -0.18 11.19 0.30 115.84 0.04 Total vertical net force ;Fw,v = 0.16 kips Total horizontal net force ;Fw,h = 0.00 kips Walls load case 4 - Wind 90, GC pi -0.18, +cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A 11.96 0.80 11.19 9.63 211.24 2.03 B 9.98 -0.46 11.19 -2.39 211.21 -0.50 C 9.98 -0.70 11.19 -4.65 200.67 -0.93 D 9.98 -0.70 11.19 -4.65 200.67 -0.93 Overall loading Projected vertical plan area of wall;Avert_w_90 = d  H + d2  tan(0) / 4 = 211.21 ft2 Projected vertical area of roof ;Avert_r_90 = 0.00 ft2 Minimum overall horizontal loading;Fw,total_min = pmin_w  Avert_w_90 + pmin_r  Avert_r_90 = 3.38 kips Leeward net force;Fl = Fw,wB = -0.5 kips Windward net force ;Fw = Fw,wA = 2.0 kips Overall horizontal loading;Fw,total = max(Fw - Fl + Fw,h, Fw,total_min) = 3.4 kips Page 29 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section Sheet no./rev. 5 Calc. by N.K Date 12/12/2023 Chk'd by Date App'd by Date Page 30 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section Sheet no./rev. 6 Calc. by N.K Date 12/12/2023 Chk'd by Date App'd by Date Page 31 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section CLADDING Sheet no./rev. 1 Calc. by N.K Date 12/12/2023 Chk'd by Date App'd by Date WIND LOADING In accordance with ASCE7-16 Using the components and cladding design method Tedds calculation version 2.1.13 Building data Type of roof;Gable Length of building;b = 25.08 ft Width of building ;d = 21.17 ft Height to eaves;H = 8.00 ft Pitch of roof;0 = 20.5 deg Mean height;h = 9.98 ft End zone width;a = max(min(0.1min(b, d), 0.4h), 0.04min(b, d), 3ft) = 3.00 ft General wind load requirements Basic wind speed;V = 95.0 mph Risk category;II Velocity pressure exponent coef (Table 26.6-1);Kd = 0.85 Ground elevation above sea level;zgl = 0 ft Ground elevation factor ;Ke = exp(-0.0000362  zgl/1ft) = 1.00 Exposure category (cl 26.7.3);B Enclosure classification (cl.26.12);Enclosed buildings Internal pressure coef +ve (Table 26.13-1);GCpi_p = 0.18 Internal pressure coef –ve (Table 26.13-1);GCpi_n = -0.18 Gust effect factor;Gf = 0.85 Topography Topography factor not significant;Kzt = 1.0 Velocity pressure Velocity pressure coefficient (Table 26.10-1);Kz = 0.57 Velocity pressure;qh = 0.00256  Kz  Kzt  Kd  Ke  V2  1psf/mph2 = 11.2 psf Page 32 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section CLADDING Sheet no./rev. 2 Calc. by N.K Date 12/12/2023 Chk'd by Date App'd by Date Peak velocity pressure for internal pressure Peak velocity pressure – internal (as roof press.);qi = 11.19 psf Equations used in tables Net pressure;p = qh  [GCp - GCpi]; Components and cladding pressures - Wall (Table 30.3-1) Component Zone Length (ft) Width (ft) Eff. area (ft2) +GCp -GCp Pres (+ve) (psf) Pres (-ve) (psf) <=10 sf 4 --10.0 1.00 -1.10 13.2 #-14.3 # 50 sf 4 --50.0 0.88 -0.98 11.8 #-12.9 # 200 sf 4 --200.0 0.77 -0.87 10.6 #-11.8 # >500 sf 4 --500.1 0.70 -0.80 9.9 #-11.0 # <=10 sf 5 --10.0 1.00 -1.40 13.2 #-17.7 50 sf 5 --50.0 0.88 -1.15 11.8 #-14.9 # 200 sf 5 --200.0 0.77 -0.94 10.6 #-12.5 # >500 sf 5 --500.1 0.70 -0.80 9.9 #-11.0 # # The final net design wind pressure, including all permitted reductions, used in the design shall not be less than 16psf acting in either direction Components and cladding pressures - Roof (Figure 30.3-2C) Component Zone Length (ft) Width (ft) Eff. area (ft2) +GCp -GCp Pres (+ve) (psf) Pres (-ve) (psf) <=2 sf 1 --2.0 0.70 -1.50 9.9 #-18.8 20 sf 1 --20.0 0.46 -1.50 7.2 #-18.8 Page 33 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section CLADDING Sheet no./rev. 3 Calc. by N.K Date 12/12/2023 Chk'd by Date App'd by Date Component Zone Length (ft) Width (ft) Eff. area (ft2) +GCp -GCp Pres (+ve) (psf) Pres (-ve) (psf) 100 sf 1 --100.0 0.30 -1.08 5.4 #-14.1 # >300 sf 1 --300.1 0.30 -0.80 5.4 #-11.0 # <=2 sf 2e --2.0 0.70 -1.50 9.9 #-18.8 20 sf 2e --20.0 0.46 -1.50 7.2 #-18.8 100 sf 2e --100.0 0.30 -1.08 5.4 #-14.1 # >300 sf 2e --300.1 0.30 -0.80 5.4 #-11.0 # <=2 sf 2n --2.0 0.70 -2.50 9.9 #-30.0 10 sf 2n --10.0 0.54 -2.50 8.0 #-30.0 100 sf 2n --100.0 0.30 -1.39 5.4 #-17.6 >150 sf 2n --150.1 0.30 -1.20 5.4 #-15.4 # <=2 sf 2r --2.0 0.70 -2.50 9.9 #-30.0 10 sf 2r --10.0 0.54 -2.50 8.0 #-30.0 100 sf 2r --100.0 0.30 -1.39 5.4 #-17.6 >150 sf 2r --150.1 0.30 -1.20 5.4 #-15.4 # <=2 sf 3e --2.0 0.70 -2.50 9.9 #-30.0 10 sf 3e --10.0 0.54 -2.50 8.0 #-30.0 100 sf 3e --100.0 0.30 -1.39 5.4 #-17.6 >150 sf 3e --150.1 0.30 -1.20 5.4 #-15.4 # <=2 sf 3r --2.0 0.70 -3.60 9.9 #-42.3 4 sf 3r --4.0 0.63 -3.60 9.1 #-42.3 10 sf 3r --10.0 0.54 -2.95 8.0 #-35.0 >50 sf 3r --50.1 0.37 -1.80 6.2 #-22.2 # The final net design wind pressure, including all permitted reductions, used in the design shall not be less than 16psf acting in either direction Page 34 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section CLADDING Sheet no./rev. 4 Calc. by N.K Date 12/12/2023 Chk'd by Date App'd by Date Page 35 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 19 Appendix D : Shear Wall Design Page 36 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-1 Sheet no./rev. 1 Calc. by N.K Date 19/12/2023 Chk'd by Date App'd by Date WOOD SHEAR WALL DESIGN (NDS) In accordance with NDS2018 and SDPWS2021 allowable stress design and the perforated shear wall method Tedds calculation version 1.2.10 Design summary Description Unit Provided Required Utilization Result Shear capacity lbs 4200 1350 0.321 PASS Chord capacity lb/in2 552 91 0.164 PASS Collector capacity lb/in2 1380 25 0.018 PASS Deflection in 0.200 0.049 0.245 PASS Panel details Structural I wood panel sheathing on one side Panel height;h = 8.333 ft Panel length;b = 17.7 ft Panel opening details Width of opening ;wo1 = 4 ft Height of opening;ho1 = 3 ft Height to underside of lintel over opening;lo1 = 6.417 ft Position of opening;Po1 = 8.833 ft Total area of wall;A = h  b - wo1  ho1 = 135.5 ft2 Panel construction Nominal stud size;2'' x 4'' Dressed stud size;1.5'' x 3.5'' Cross-sectional area of studs;As = 5.25 in2 Stud spacing;s = 16 in Page 37 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-1 Sheet no./rev. 2 Calc. by N.K Date 19/12/2023 Chk'd by Date App'd by Date Nominal end post size;4'' x 4'' Dressed end post size;3.5'' x 3.5'' Cross-sectional area of end posts;Ae = 12.25 in2 Hole diameter;Dia = 0.625 in Net cross-sectional area of end posts;Aen = 10.062 in2 Nominal collector size;2 x 2'' x 4'' Dressed collector size;2 x 1.5'' x 3.5'' Service condition;Dry Temperature;100 degF or less Anchor location ;Inside face Anchor offset;eanchor = 0 in Vertical anchor stiffness;ka = 34000 lb/in From NDS Supplement Table 4A - Reference design values for visually graded dimension lumber (2'' - 4'' thick) Species, grade and size classification;Douglas Fir-Larch, no.2 grade, 2'' & wider Specific gravity;G = 0.50 Tension parallel to grain;Ft = 575 lb/in2 Compression parallel to grain;Fc = 1350 lb/in2 Compression perpendicular to grain;Fc_perp = 625 lb/in2 Modulus of elasticity;E = 1600000 lb/in2 Minimum modulus of elasticity;Emin = 580000 lb/in2 Sheathing details Sheathing material;15/32'' wood panel structural I 3-ply plywood sheathing Fastener type;10d common nails at 6''centers From SDPWS Table 4.3A Nominal Unit Shear Capacities for Wood-Frame Shear Walls - Wood-based Panels Nominal unit shear capacity;vn = min(950 plf  0.92, 2435 plf) = 874 lb/ft Apparent shear wall shear stiffness;Ga = 16 kips/in Loading details Dead load acting on top of panel;D = 208.92 lb/ft Floor live load acting on top of panel;Lf = 181.667 lb/ft Roof live load acting on top of panel;Lr = 181.667 lb/ft Self weight of panel;Swt = 18 lb/ft2 In plane wind load acting at head of panel;W = 1700 lbs Wind load serviceability factor ;fWserv = 0.60 In plane seismic load acting at head of panel;Eq = 1928 lbs Design spectral response accel. par., short periods;SDS = 1.036 From ASCE 7-16 - cl.2.4.1 and cl. 2.4.5 Basic combinations Load combination no.1 ;D + 0.6W Load combination no.2 ;D + 0.7E Load combination no.3 ;D + 0.75Lf + 0.45W + 0.75(L r or S or R) Load combination no.4 ;D + 0.75Lf + 0.525E + 0.75S Load combination no.5 ;0.6D + 0.6W Load combination no.6 ;0.6D + 0.7E Adjustment factors Load duration factor – Table 2.3.2;CD = 1.60 Page 38 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-1 Sheet no./rev. 3 Calc. by N.K Date 19/12/2023 Chk'd by Date App'd by Date Size factor for tension – Table 4A;CFt = 1.50 Size factor for compression – Table 4A;CFc = 1.15 Wet service factor for tension – Table 4A;CMt = 1.00 W et service factor for compression – Table 4A;CMc = 1.00 Wet service factor for modulus of elasticity – Table 4A CME = 1.00 Temperature factor for tension – Table 2.3.3;Ctt = 1.00 Temperature factor for compression – Table 2.3.3 Ctc = 1.00 Temperature factor for modulus of elasticity – Table 2.3.3 CtE = 1.00 Incising factor – cl.4.3.8;Ci = 1.00 Buckling stiffness factor – cl.4.4.2;CT = 1.00 Bearing area factor - cl. 3.10.4 ;Cb = 1.0 Adjusted modulus of elasticity;Emin' = Emin  CME  CtE  Ci  CT = 580000 psi Critical buckling design value;FcE = 0.822  Emin' / (h / d)2 = 584 psi Reference compression design value;Fc = Fc  CD  CMc  Ctc  CFc  Ci = 2484 psi For sawn lumber;c = 0.8 Column stability factor – eqn.3.7-1;CP = (1 + (FcE / Fc)) / (2  c) – ([(1 + (FcE / Fc)) / (2  c)]2 - (FcE / Fc) / c) = 0.22 From SDPWS Table 4.3.3 Maximum Shear Wall Aspect Ratios Maximum shear wall aspect ratio;3.5 Perforated wall length;b1 = 8.833 ft Shear wall aspect ratio;h / b1 = 0.943 Perforated wall length;b2 = 4.867 ft Shear wall aspect ratio;h / b2 = 1.712 Shear capacity adjustment factor – cl.4.3.5.6 Sum of perforated shear wall segment lengths;bi = b1 + b2 = 13.7 ft Total area of wall;Awall = b  h = 147.5 ft2 Total area of openings;Ao = wo1  ho1 = 12 ft2 Total full height sheathed area;Afhs = h  (b1 + b2) = 114.17 ft2 Shear capacity adjustment factor (eqn. 4.3-6);Co = min(Awall / (3  Ao + Afhs), 1.0) = 0.982 Perforated shear wall capacity Maximum shear force under wind loading;Vw_max = 0.6  W = 1.02 kips Shear capacity for wind loading;Vw = vw  Co  bi / 2.0 = 5.881 kips Vw_max / Vw = 0.173 PASS - Shear capacity for wind load exceeds maximum shear force Maximum shear force under seismic loading;Vs_max = 0.7  Eq = 1.35 kips Shear capacity for seismic loading;Vs = vs  Co  bi / 2.8 = 4.2 kips Vs_max / Vs = 0.321 PASS - Shear capacity for seismic load exceeds maximum shear force Chord capacity for chords 1 and 2 Load combination 6 Page 39 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-1 Sheet no./rev. 4 Calc. by N.K Date 19/12/2023 Chk'd by Date App'd by Date Shear force for maximum tension;V = 0.7  Eq = 1.35 kips Axial force for maximum tension;P = (0.6  (D + Swt  h) - 0.7  0.2  SDS  (D + Swt  h))  b / 2 = 1.445 kips Maximum tensile force in chord;T = V  h / (Co  bi) - P = -0.609 kips Maximum applied tensile stress;ft = T / Aen = -61 lb/in2 Design tensile stress;Ft' = Ft  CD  CMt  Ctt  CFt  Ci = 1380 lb/in2 ft / Ft' = -0.044 PASS - Design tensile stress exceeds maximum applied tensile stress Load combination 2 Shear force for maximum compression;V = 0.7  Eq = 1.35 kips Axial force for maximum compression;P = ((D + Swt  h) + 0.7  0.2  SDS  (D + Swt  h))  s / 2 = 0.274 kips Maximum compressive force in chord;C = V  h / (Co  bi) + P = 1.110 kips Maximum applied compressive stress;fc = C / Ae = 91 lb/in2 Design compressive stress;Fc' = Fc  CD  CMc  Ctc  CFc  Ci  CP = 552 lb/in2 fc / Fc' = 0.164 PASS - Design compressive stress exceeds maximum applied compressive stress Design bearing compr. stress, bottom plate;Fc_perp' = Fc_perp  CMc  Ctc  Ci  Cb = 625 lb/in2 fc / Fc_perp' = 0.145 PASS - Design bearing compressive stress exceeds maximum applied bearing compressive stress Collector capacity Collector seismic design force factor;FColl = 1 Maximum shear force on wall;Vmax = max(FColl  Vs_max, Vw_max) = 1.35 kips Uniform shear applied to wall;va = Vmax / (Co  bi) = 100.3 plf Shear resisted by wall segments;vb = va  b / (b1 + b2) = 129.6 plf Maximum force in collector;Pcoll = 0.259 kips Maximum applied tensile stress;ft = Pcoll / (2  As) = 25 lb/in2 Design tensile stress;Ft' = Ft  CD  CMt  Ctt  CFt  Ci = 1380 lb/in2 ft / Ft' = 0.018 PASS - Design tensile stress exceeds maximum applied tensile stress Maximum applied compressive stress;fc = Pcoll / (2  As) = 25 lb/in2 Column stability factor;CP = 1.00 Design compressive stress;Fc' = Fc  CD  CMc  Ctc  CFc  Ci  CP = 2484 lb/in2 Page 40 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-1 Sheet no./rev. 5 Calc. by N.K Date 19/12/2023 Chk'd by Date App'd by Date fc / Fc' = 0.010 PASS - Design compressive stress exceeds maximum applied compressive stress Wind load deflection Design shear force;Vw = fWserv  W = 1.02 kips Deflection limit;w_allow= h / 500 = 0.2 in Induced unit shear;vw_max = Vw / (Co  bi) = 75.8 lb/ft Anchor tension force;T = max(0 kips,vw_max  h - 0.6  (D + Swt  h)  b / 2) = 0.000 kips Chord compression force;C = max(0 kips,vw_max  h + 0.6  (D + Swt  h)  b / 2) = 2.538 kips Vertical elongation at anchor;T = T / ka = 0.000 in Vertical compression at chord;C = 0.04 in  C / (Ae  Fc_perp) = 0.013 in Total vertical deflection ;a = (T + C)  (b / beff) = 0.014 in Shear wall deflection – Eqn. 4.3-1;sww = 2  vw_max  h3 / (3  E  Ae  bi) + vw_max  h / (Ga) + h  a / bi = 0.049 in sww / w_allow = 0.245 PASS - Shear wall deflection is less than deflection limit Seismic deflection Design shear force;Vs = Eq = 1.928 kips Deflection limit;s_allow= 0.025  h = 2.5 in Induced unit shear;vs_max = Vs / (Co  bi) = 143.27 lb/ft Anchor tension force;T = max(0 kips,vs_max  h - (0.6 - 0.2  SDS)  (D + Swt  h)  b / 2) = 0.000 kips Chord compression force;C = max(0 kips,vs_max  h + (0.6 - 0.2  SDS)  (D + Swt  h)  b / 2) = 2.442 kips Vertical elongation at anchor;T = T / ka = 0.000 in Vertical compression at chord;C = 0.04 in  C / (Ae  Fc_perp) = 0.013 in Total vertical deflection ;a = (T + C)  (b / beff) = 0.013 in Shear wall elastic deflection – Eqn. 4.3-1;swse = 2  vs_max  h3 / (3  E  Ae  bi) + vs_max  h / (Ga) + h  a / bi = 0.085 in Deflection ampification factor;Cd = 4 Seismic importance factor;Ie = 1 Amp. seis. deflection – ASCE7 Eqn. 12.8-15;sws = Cd  swse / Ie = 0.34 in sws / s_allow = 0.136 PASS - Shear wall deflection is less than deflection limit Page 41 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-2 Sheet no./rev. 1 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date WOOD SHEAR WALL DESIGN (NDS) In accordance with NDS2018 and SDPWS2021 allowable stress design and the segmented shear wall method Tedds calculation version 1.2.10 Design summary Description Unit Provided Required Utilization Result Shear capacity lbs 6898 1535 0.223 PASS Chord capacity lb/in2 552 71 0.128 PASS Deflection in 0.200 0.030 0.151 PASS Panel details Structural I wood panel sheathing on one side Panel height;h = 8.333 ft Panel length;b = 22.1 ft Total area of wall;A = h  b = 184.167 ft2 Panel construction Nominal stud size;2'' x 4'' Dressed stud size;1.5'' x 3.5'' Cross-sectional area of studs;As = 5.25 in2 Stud spacing;s = 16 in Nominal end post size;4'' x 4'' Dressed end post size;3.5'' x 3.5'' Cross-sectional area of end posts;Ae = 12.25 in2 Hole diameter;Dia = 0.625 in Net cross-sectional area of end posts;Aen = 10.062 in2 Nominal collector size;2 x 2'' x 4'' Dressed collector size;2 x 1.5'' x 3.5'' Service condition;Dry Temperature;100 degF or less Page 42 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-2 Sheet no./rev. 2 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date Anchor location ;Inside face Anchor offset;eanchor = 0 in Vertical anchor stiffness;ka = 10000 lb/in From NDS Supplement Table 4A - Reference design values for visually graded dimension lumber (2'' - 4'' thick) Species, grade and size classification;Douglas Fir-Larch, no.2 grade, 2'' & wider Specific gravity;G = 0.50 Tension parallel to grain;Ft = 575 lb/in2 Compression parallel to grain;Fc = 1350 lb/in2 Compression perpendicular to grain;Fc_perp = 625 lb/in2 Modulus of elasticity;E = 1600000 lb/in2 Minimum modulus of elasticity;Emin = 580000 lb/in2 Sheathing details Sheathing material;15/32'' wood panel structural I 4-ply plywood sheathing Fastener type;10d common nails at 6''centers From SDPWS Table 4.3A Nominal Unit Shear Capacities for Wood-Frame Shear Walls - Wood-based Panels Nominal unit shear capacity;vn = 950 plf  0.92 = 874 lb/ft Apparent shear wall shear stiffness;Ga = 16 kips/in Loading details Dead load acting on top of panel;D = 208.92 lb/ft Floor live load acting on top of panel;Lf = 181.667 lb/ft Roof live load acting on top of panel;Lr = 181.667 lb/ft Self weight of panel;Swt = 18 lb/ft2 In plane wind load acting at head of panel;W = 1700 lbs Wind load serviceability factor ;fWserv = 0.60 In plane seismic load acting at head of panel;Eq = 2193 lbs Design spectral response accel. par., short periods;SDS = 1.036 From ASCE 7-16 - cl.2.4.1 and cl. 2.4.5 Basic combinations Load combination no.1 ;D + 0.6W Load combination no.2 ;D + 0.7E Load combination no.3 ;D + 0.75Lf + 0.45W + 0.75(L r or S or R) Load combination no.4 ;D + 0.75Lf + 0.525E + 0.75S Load combination no.5 ;0.6D + 0.6W Load combination no.6 ;0.6D + 0.7E Adjustment factors Load duration factor – Table 2.3.2;CD = 1.60 Size factor for tension – Table 4A;CFt = 1.50 Size factor for compression – Table 4A;CFc = 1.15 Wet service factor for tension – Table 4A;CMt = 1.00 W et service factor for compression – Table 4A;CMc = 1.00 Wet service factor for modulus of elasticity – Table 4A CME = 1.00 Temperature factor for tension – Table 2.3.3;Ctt = 1.00 Temperature factor for compression – Table 2.3.3 Ctc = 1.00 Page 43 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-2 Sheet no./rev. 3 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date Temperature factor for modulus of elasticity – Table 2.3.3 CtE = 1.00 Incising factor – cl.4.3.8;Ci = 1.00 Buckling stiffness factor – cl.4.4.2;CT = 1.00 Bearing area factor - cl. 3.10.4 ;Cb = 1.0 Adjusted modulus of elasticity;Emin' = Emin  CME  CtE  Ci  CT = 580000 psi Critical buckling design value;FcE = 0.822  Emin' / (h / d)2 = 584 psi Reference compression design value;Fc = Fc  CD  CMc  Ctc  CFc  Ci = 2484 psi For sawn lumber;c = 0.8 Column stability factor – eqn.3.7-1;CP = (1 + (FcE / Fc)) / (2  c) – ([(1 + (FcE / Fc)) / (2  c)]2 - (FcE / Fc) / c) = 0.22 From SDPWS Table 4.3.3 Maximum Shear Wall Aspect Ratios Maximum shear wall aspect ratio;3.5 Shear wall length;b = 22.1 ft Shear wall aspect ratio;h / b = 0.377 Segmented shear wall capacity Maximum shear force under wind loading;Vw_max = 0.6  W = 1.02 kips Shear capacity for wind loading;Vw = vw  b / 2.0 = 9.658 kips Vw_max / Vw = 0.106 PASS - Shear capacity for wind load exceeds maximum shear force Maximum shear force under seismic loading;Vs_max = 0.7  Eq = 1.535 kips Shear capacity for seismic loading;Vs = vs  b / 2.8 = 6.898 kips Vs_max / Vs = 0.223 PASS - Shear capacity for seismic load exceeds maximum shear force Chord capacity for chords 1 and 2 Shear wall aspect ratio;h / b = 0.377 Effective length for chord forces ;beff = b - 3 / 2  bEndPost - eanchor = 21.66 ft Load combination 6 Shear force for maximum tension;V = 0.7  Eq = 1.535 kips Axial force for maximum tension;P = (0.6  (D + Swt  h) - 0.7  0.2  SDS  (D + Swt  h))  b1 / 2 = 1.804 kips Maximum tensile force in chord;T = V  h / beff - P = -1.214 kips Maximum applied tensile stress;ft = T / Aen = -121 lb/in2 Design tensile stress;Ft' = Ft  CD  CMt  Ctt  CFt  Ci = 1380 lb/in2 ft / Ft' = -0.087 PASS - Design tensile stress exceeds maximum applied tensile stress Load combination 2 Shear force for maximum compression;V = 0.7  Eq = 1.535 kips Axial force for maximum compression;P = ((D + Swt  h) + 0.7  0.2  SDS  (D + Swt  h))  s / 2 = 0.274 kips Maximum compressive force in chord;C = V  h / beff + P = 0.865 kips Maximum applied compressive stress;fc = C / Ae = 71 lb/in2 Design compressive stress;Fc' = Fc  CD  CMc  Ctc  CFc  Ci  CP = 552 lb/in2 fc / Fc' = 0.128 Page 44 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-2 Sheet no./rev. 4 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date PASS - Design compressive stress exceeds maximum applied compressive stress Design bearing compr. stress, bottom plate;Fc_perp' = Fc_perp  CMc  Ctc  Ci  Cb = 625 lb/in2 fc / Fc_perp' = 0.113 PASS - Design bearing compressive stress exceeds maximum applied bearing compressive stress Wind load deflection Design shear force;Vw = fWserv  W = 1.02 kips Deflection limit;w_allow= h / 500 = 0.2 in Induced unit shear;vw = Vw / b = 46.15 lb/ft Anchor tension force;T = max(0 kips,vw  h  b / beff - 0.6  (D + Swt  h)  b / 2) = 0.000 kips Chord compression force;C = max(0 kips,vw  h  b / beff + 0.6  (D + Swt  h)  b / 2) = 2.772 kips Vertical elongation at anchor;T = T / ka = 0.000 in Vertical compression at chord;C = 0.04 in  C / (Ae  Fc_perp) = 0.014 in Total vertical deflection ;a = (T + C)  (b / beff) = 0.015 in Shear wall deflection – Eqn. 4.3-1;sww = 2  vw  h3 / (3  E  Ae  b) + vw  h / (Ga) + h  a / b = 0.03 in sww / w_allow = 0.151 PASS - Shear wall deflection is less than deflection limit Seismic deflection Design shear force;Vs = Eq = 2.193 kips Deflection limit;s_allow= 0.025  h = 2.5 in Induced unit shear;vs = Vs / b = 99.23 lb/ft Anchor tension force;T = max(0 kips,vs  h  b / beff - (0.6 - 0.2  SDS)  (D + Swt  h)  b / 2) = 0.000 kips Chord compression force;C = max(0 kips,vs  h  b / beff + (0.6 - 0.2  SDS)  (D + Swt  h)  b / 2) = 2.401 kips Vertical elongation at anchor;T = T / ka = 0.000 in Vertical compression at chord;C = 0.04 in  C / (Ae  Fc_perp) = 0.013 in Total vertical deflection ;a = (T + C)  (b / beff) = 0.013 in Shear wall elastic deflection – Eqn. 4.3-1;swse = 2  vs  h3 / (3  E  Ae  b) + vs  h / (Ga) + h  a / b = 0.058 in Deflection ampification factor;Cd = 4 Seismic importance factor;Ie = 1 Amp. seis. deflection – ASCE7 Eqn. 12.8-15;sws = Cd  swse / Ie = 0.23 in sws / s_allow = 0.092 PASS - Shear wall deflection is less than deflection limit Page 45 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-A Sheet no./rev. 1 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date WOOD SHEAR WALL DESIGN (NDS) In accordance with NDS2018 and SDPWS2021 allowable stress design and the segmented shear wall method Tedds calculation version 1.2.10 Design summary Description Unit Provided Required Utilization Result Shear capacity lbs 5669 1535 0.271 PASS Chord capacity lb/in2 552 100 0.181 PASS Deflection in 0.200 0.040 0.198 PASS Panel details Structural I wood panel sheathing on one side Panel height;h = 8.333 ft Panel length;b = 18.16 ft Total area of wall;A = h  b = 151.333 ft2 Panel construction Nominal stud size;2'' x 4'' Dressed stud size;1.5'' x 3.5'' Cross-sectional area of studs;As = 5.25 in2 Stud spacing;s = 16 in Nominal end post size;4'' x 4'' Dressed end post size;3.5'' x 3.5'' Cross-sectional area of end posts;Ae = 12.25 in2 Hole diameter;Dia = 0.625 in Net cross-sectional area of end posts;Aen = 10.062 in2 Nominal collector size;2 x 2'' x 4'' Dressed collector size;2 x 1.5'' x 3.5'' Page 46 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-A Sheet no./rev. 2 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date Service condition;Dry Temperature;100 degF or less Anchor location ;Inside face Anchor offset;eanchor = 0 in Vertical anchor stiffness;ka = 10000 lb/in From NDS Supplement Table 4A - Reference design values for visually graded dimension lumber (2'' - 4'' thick) Species, grade and size classification;Douglas Fir-Larch, no.2 grade, 2'' & wider Specific gravity;G = 0.50 Tension parallel to grain;Ft = 575 lb/in2 Compression parallel to grain;Fc = 1350 lb/in2 Compression perpendicular to grain;Fc_perp = 625 lb/in2 Modulus of elasticity;E = 1600000 lb/in2 Minimum modulus of elasticity;Emin = 580000 lb/in2 Sheathing details Sheathing material;15/32'' wood panel structural I 4-ply plywood sheathing Fastener type;10d common nails at 6''centers From SDPWS Table 4.3A Nominal Unit Shear Capacities for Wood-Frame Shear Walls - Wood-based Panels Nominal unit shear capacity;vn = 950 plf  0.92 = 874 lb/ft Apparent shear wall shear stiffness;Ga = 16 kips/in Loading details Dead load acting on top of panel;D = 15.36 lb/ft Floor live load acting on top of panel;Lf = 13.4 lb/ft Roof live load acting on top of panel;Lr = 13.4 lb/ft Self weight of panel;Swt = 18 lb/ft2 In plane wind load acting at head of panel;W = 2000 lbs Wind load serviceability factor ;fWserv = 0.60 In plane seismic load acting at head of panel;Eq = 2193 lbs Design spectral response accel. par., short periods;SDS = 1.036 Chord forces from shear walls above Chord Wch[i] (lbs)Eq_ch[i] (lbs)DC_ch[i] (lbs)DT_ch[i] (lbs)Lf_ch[i] (lbs)Lr_ch[i] (lbs)Sch[i] (lbs)Rch[i] (lbs) Ch1;-506;-599;0;0;0;0;0;0; Ch2;460;540;0;0;0;0;0;0; From ASCE 7-16 - cl.2.4.1 and cl. 2.4.5 Basic combinations Load combination no.1 ;D + 0.6W Load combination no.2 ;D + 0.7E Load combination no.3 ;D + 0.75Lf + 0.45W + 0.75(L r or S or R) Load combination no.4 ;D + 0.75Lf + 0.525E + 0.75S Load combination no.5 ;0.6D + 0.6W Load combination no.6 ;0.6D + 0.7E Adjustment factors Load duration factor – Table 2.3.2;CD = 1.60 Size factor for tension – Table 4A;CFt = 1.50 Size factor for compression – Table 4A;CFc = 1.15 Page 47 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-A Sheet no./rev. 3 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date Wet service factor for tension – Table 4A;CMt = 1.00 W et service factor for compression – Table 4A;CMc = 1.00 Wet service factor for modulus of elasticity – Table 4A CME = 1.00 Temperature factor for tension – Table 2.3.3;Ctt = 1.00 Temperature factor for compression – Table 2.3.3 Ctc = 1.00 Temperature factor for modulus of elasticity – Table 2.3.3 CtE = 1.00 Incising factor – cl.4.3.8;Ci = 1.00 Buckling stiffness factor – cl.4.4.2;CT = 1.00 Bearing area factor - cl. 3.10.4 ;Cb = 1.0 Adjusted modulus of elasticity;Emin' = Emin  CME  CtE  Ci  CT = 580000 psi Critical buckling design value;FcE = 0.822  Emin' / (h / d)2 = 584 psi Reference compression design value;Fc = Fc  CD  CMc  Ctc  CFc  Ci = 2484 psi For sawn lumber;c = 0.8 Column stability factor – eqn.3.7-1;CP = (1 + (FcE / Fc)) / (2  c) – ([(1 + (FcE / Fc)) / (2  c)]2 - (FcE / Fc) / c) = 0.22 From SDPWS Table 4.3.3 Maximum Shear Wall Aspect Ratios Maximum shear wall aspect ratio;3.5 Shear wall length;b = 18.16 ft Shear wall aspect ratio;h / b = 0.459 Segmented shear wall capacity Maximum shear force under wind loading;Vw_max = 0.6  W = 1.2 kips Shear capacity for wind loading;Vw = vw  b / 2.0 = 7.936 kips Vw_max / Vw = 0.151 PASS - Shear capacity for wind load exceeds maximum shear force Maximum shear force under seismic loading;Vs_max = 0.7  Eq = 1.535 kips Shear capacity for seismic loading;Vs = vs  b / 2.8 = 5.669 kips Vs_max / Vs = 0.271 PASS - Shear capacity for seismic load exceeds maximum shear force Chord capacity for chord 1 Shear wall aspect ratio;h / b = 0.459 Effective length for chord forces ;beff = b - 3 / 2  bEndPost - eanchor = 17.72 ft Load combination 6 Shear force for maximum tension;V = 0.7  Eq = 1.535 kips Axial force for maximum tension;P = (0.6  (D + Swt  h) - 0.7  0.2  SDS  (D + Swt  h))  b1 / 2 + 0.7  Eq_ch1 = 0.264 kips Maximum tensile force in chord;T = V  h / beff - P = 0.458 kips Maximum applied tensile stress;ft = T / Aen = 46 lb/in2 Design tensile stress;Ft' = Ft  CD  CMt  Ctt  CFt  Ci = 1380 lb/in2 ft / Ft' = 0.033 PASS - Design tensile stress exceeds maximum applied tensile stress Page 48 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-A Sheet no./rev. 4 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date Load combination 2 Shear force for maximum compression;V = 0.7  Eq = 1.535 kips Axial force for maximum compression;P = ((D + Swt  h) + 0.7  0.2  SDS  (D + Swt  h))  s / 2 + -1  0.7  Eq_ch1 = 0.546 kips Maximum compressive force in chord;C = V  h / beff + P = 1.268 kips Maximum applied compressive stress;fc = C / Ae = 103 lb/in2 Design compressive stress;Fc' = Fc  CD  CMc  Ctc  CFc  Ci  CP = 552 lb/in2 fc / Fc' = 0.187 PASS - Design compressive stress exceeds maximum applied compressive stress Design bearing compr. stress, bottom plate;Fc_perp' = Fc_perp  CMc  Ctc  Ci  Cb = 625 lb/in2 fc / Fc_perp' = 0.166 PASS - Design bearing compressive stress exceeds maximum applied bearing compressive stress Chord capacity for chord 2 Load combination 6 Shear force for maximum tension;V = 0.7  Eq = 1.535 kips Axial force for maximum tension;P = (0.6  (D + Swt  h) - 0.7  0.2  SDS  (D + Swt  h))  b1 / 2 + -1  0.7  Eq_ch2 = 0.305 kips Maximum tensile force in chord;T = V  h / beff - P = 0.417 kips Maximum applied tensile stress;ft = T / Aen = 41 lb/in2 Design tensile stress;Ft' = Ft  CD  CMt  Ctt  CFt  Ci = 1380 lb/in2 ft / Ft' = 0.030 PASS - Design tensile stress exceeds maximum applied tensile stress Load combination 2 Shear force for maximum compression;V = 0.7  Eq = 1.535 kips Axial force for maximum compression;P = ((D + Swt  h) + 0.7  0.2  SDS  (D + Swt  h))  s / 2 + 0.7  Eq_ch2 = 0.504 kips Maximum compressive force in chord;C = V  h / beff + P = 1.226 kips Maximum applied compressive stress;fc = C / Ae = 100 lb/in2 Design compressive stress;Fc' = Fc  CD  CMc  Ctc  CFc  Ci  CP = 552 lb/in2 fc / Fc' = 0.181 PASS - Design compressive stress exceeds maximum applied compressive stress Design bearing compr. stress, bottom plate;Fc_perp' = Fc_perp  CMc  Ctc  Ci  Cb = 625 lb/in2 fc / Fc_perp' = 0.160 PASS - Design bearing compressive stress exceeds maximum applied bearing compressive stress Hold down force Chord 1;T1 = 0.458 kips Chord 2;T2 = 0.417 kips Wind load deflection Design shear force;Vw = fWserv  W = 1.2 kips Deflection limit;w_allow= h / 500 = 0.2 in Induced unit shear;vw = Vw / b = 66.08 lb/ft Anchor tension force;T = max(0 kips,vw  h  b / beff - 0.6  (D + Swt  h)  b / 2 + 0.6  max(abs(W ch1),abs(W ch2))) = 0.000 kips Page 49 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-A Sheet no./rev. 5 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date Chord compression force;C = max(0 kips,vw  h  b / beff + 0.6  (D + Swt  h)  b / 2 + 0.6  max(abs(W ch1),abs(W ch2))) = 1.769 kips Vertical elongation at anchor;T = T / ka = 0.000 in Vertical compression at chord;C = 0.04 in  C / (Ae  Fc_perp) = 0.009 in Total vertical deflection ;a = (T + C)  (b / beff) = 0.009 in Shear wall deflection – Eqn. 4.3-1;sww = 2  vw  h3 / (3  E  Ae  b) + vw  h / (Ga) + h  a / b = 0.04 in sww / w_allow = 0.198 PASS - Shear wall deflection is less than deflection limit Seismic deflection Design shear force;Vs = Eq = 2.193 kips Deflection limit;s_allow= 0.025  h = 2.5 in Induced unit shear;vs = Vs / b = 120.76 lb/ft Anchor tension force;T = max(0 kips,vs  h  b / beff - (0.6 - 0.2  SDS)  (D + Swt  h)  b / 2 + max(abs(Eq_ch1),abs(Eq_ch2))) = 1.041 kips Chord compression force;C = max(0 kips,vs  h  b / beff + (0.6 - 0.2  SDS)  (D + Swt  h)  b / 2 + max(abs(Eq_ch1),abs(Eq_ch2))) = 2.220 kips Vertical elongation at anchor;T = T / ka = 0.104 in Vertical compression at chord;C = 0.04 in  C / (Ae  Fc_perp) = 0.012 in Total vertical deflection ;a = (T + C)  (b / beff) = 0.119 in Shear wall elastic deflection – Eqn. 4.3-1;swse = 2  vs  h3 / (3  E  Ae  b) + vs  h / (Ga) + h  a / b = 0.119 in Deflection ampification factor;Cd = 4 Seismic importance factor;Ie = 1 Amp. seis. deflection – ASCE7 Eqn. 12.8-15;sws = Cd  swse / Ie = 0.475 in sws / s_allow = 0.19 PASS - Shear wall deflection is less than deflection limit Page 50 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-B Sheet no./rev. 1 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date WOOD SHEAR WALL DESIGN (NDS) In accordance with NDS2018 and SDPWS2021 allowable stress design and the segmented shear wall method Tedds calculation version 1.2.10 Design summary Description Unit Provided Required Utilization Result Shear capacity lbs 4500 1350 0.300 PASS Chord capacity lb/in2 552 146 0.264 PASS Collector capacity lb/in2 1380 42 0.031 PASS Deflection in 0.200 0.191 0.955 PASS Panel details Structural I wood panel sheathing on one side Panel height;h = 8.333 ft Panel length;b = 18.167 ft Panel opening details Width of opening ;wo1 = 12 ft Height of opening;ho1 = 7 ft Height to underside of lintel over opening;lo1 = 7 ft Position of opening;Po1 = 3.083 ft Total area of wall;A = h  b - wo1  ho1 = 67.389 ft2 Panel construction Nominal stud size;2'' x 4'' Dressed stud size;1.5'' x 3.5'' Cross-sectional area of studs;As = 5.25 in2 Stud spacing;s = 16 in Page 51 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-B Sheet no./rev. 2 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date Nominal end post size;6'' x 4'' Dressed end post size;5.5'' x 3.5'' Cross-sectional area of end posts;Ae = 19.25 in2 Hole diameter;Dia = 0.625 in Net cross-sectional area of end posts;Aen = 15.812 in2 Nominal collector size;2 x 2'' x 4'' Dressed collector size;2 x 1.5'' x 3.5'' Service condition;Dry Temperature;100 degF or less Anchor location ;Inside face Anchor offset;eanchor = 0 in Vertical anchor stiffness;ka = 48696 lb/in From NDS Supplement Table 4A - Reference design values for visually graded dimension lumber (2'' - 4'' thick) Species, grade and size classification;Douglas Fir-Larch, no.2 grade, 2'' & wider Specific gravity;G = 0.50 Tension parallel to grain;Ft = 575 lb/in2 Compression parallel to grain;Fc = 1350 lb/in2 Compression perpendicular to grain;Fc_perp = 625 lb/in2 Modulus of elasticity;E = 1600000 lb/in2 Minimum modulus of elasticity;Emin = 580000 lb/in2 Sheathing details Sheathing material;15/32'' wood panel structural I 3-ply plywood sheathing Fastener type;10d common nails at 2''centers From SDPWS Table 4.3A Nominal Unit Shear Capacities for Wood-Frame Shear Walls - Wood-based Panels Nominal unit shear capacity;vn = 2435 plf  0.92 = 2240.2 lb/ft Apparent shear wall shear stiffness;Ga = 28 kips/in Loading details Dead load acting on top of panel;D = 15.36 lb/ft Floor live load acting on top of panel;Lf = 13.4 lb/ft Roof live load acting on top of panel;Lr = 13.4 lb/ft Self weight of panel;Swt = 18 lb/ft2 In plane wind load acting at head of panel;W = 2000 lbs Wind load serviceability factor ;fWserv = 0.60 In plane seismic load acting at head of panel;Eq = 1928 lbs Design spectral response accel. par., short periods;SDS = 1.036 Chord forces from shear walls above Chord Wch[i] (lbs)Eq_ch[i] (lbs)DC_ch[i] (lbs)DT_ch[i] (lbs)Lf_ch[i] (lbs)Lr_ch[i] (lbs)Sch[i] (lbs)Rch[i] (lbs) Ch1;-506;-527;0;0;0;0;0;0; Ch2;506;527;694;0;41;760;0;0; Ch3;-460;-475;694;0;41;760;0;0; Ch4;460;475;0;0;0;0;0;0; From ASCE 7-16 - cl.2.4.1 and cl. 2.4.5 Basic combinations Load combination no.1 ;D + 0.6W Load combination no.2 ;D + 0.7E Page 52 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-B Sheet no./rev. 3 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date Load combination no.3 ;D + 0.75Lf + 0.45W + 0.75(L r or S or R) Load combination no.4 ;D + 0.75Lf + 0.525E + 0.75S Load combination no.5 ;0.6D + 0.6W Load combination no.6 ;0.6D + 0.7E Adjustment factors Load duration factor – Table 2.3.2;CD = 1.60 Size factor for tension – Table 4A;CFt = 1.50 Size factor for compression – Table 4A;CFc = 1.15 Wet service factor for tension – Table 4A;CMt = 1.00 W et service factor for compression – Table 4A;CMc = 1.00 Wet service factor for modulus of elasticity – Table 4A CME = 1.00 Temperature factor for tension – Table 2.3.3;Ctt = 1.00 Temperature factor for compression – Table 2.3.3 Ctc = 1.00 Temperature factor for modulus of elasticity – Table 2.3.3 CtE = 1.00 Incising factor – cl.4.3.8;Ci = 1.00 Buckling stiffness factor – cl.4.4.2;CT = 1.00 Bearing area factor - cl. 3.10.4 ;Cb = 1.0 Adjusted modulus of elasticity;Emin' = Emin  CME  CtE  Ci  CT = 580000 psi Critical buckling design value;FcE = 0.822  Emin' / (h / d)2 = 584 psi Reference compression design value;Fc = Fc  CD  CMc  Ctc  CFc  Ci = 2484 psi For sawn lumber;c = 0.8 Column stability factor – eqn.3.7-1;CP = (1 + (FcE / Fc)) / (2  c) – ([(1 + (FcE / Fc)) / (2  c)]2 - (FcE / Fc) / c) = 0.22 From SDPWS Table 4.3.3 Maximum Shear Wall Aspect Ratios Maximum shear wall aspect ratio;3.5 Segment 1 wall length ;b1 = 3.083 ft Shear wall aspect ratio;h / b1 = 2.703 Segment 2 wall length ;b2 = 3.083 ft Shear wall aspect ratio;h / b2 = 2.703 Segmented shear wall capacity - Equal deflection method Effective segment length;b1_eff = b1 - 3 / 2  bEndPost - eanchor = 2.40 ft Effective segment length;b2_eff = b2 - 3 / 2  bEndPost - eanchor = 2.40 ft Wind loading: Segment 1 vertical unit deflection ;a1 = h / b1  (1 / ka + (0.04 in / (Ae  Fc_perp))  (b1 / b1_eff)) = 0.067 in/kip Segment 1 stiffness;k1 = 1 / (2  h3 / (3  E  Ae  b12) + h / (Ga  b1) + h  a1 / b1) = 3.406 kips/in Unit shear capacity, widest segment;vsww1 = vw  (1.25 - 0.125  h / b1) / 2.0 = 1021.7 plf Vertical deflction under capacity load;a_Cap = h  vsww1  (1 / ka + (0.04 in / (Ae  Fc_perp))  (b1 / b1_eff)) = 0.211 in Deflection under capacity load;Cap = 2  vsww1  h3 / (3  E  Ae  b1) + vsww1  h / (Ga) + h  a_Cap / b1 = 0.925 in Segment 2 vertical unit deflection ;a1 = h / b2  (1 / ka + (0.04 in / (Ae  Fc_perp))  (b2 / b2_eff)) = 0.067 in/kip Page 53 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-B Sheet no./rev. 4 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date Segment 2 stiffness;k2 = 1 / (2  h3 / (3  E  Ae  b22) + h / (Ga  b2) + h  a1 / b2) = 3.406 kips/in Segment 2 unit shear at Cap;vdsww2 = Cap  k2 / b2 = 1021.71 plf Segment 2 shear capacity ;vsww2 = vw  (1.25 - 0.125  h / b2) / 2.0 = 1021.71 plf vdsww2 / vsww2 = 1.000 PASS - Segment shear capacity exceeds segment unit shear at Cap Maximum shear force under wind loading;Vw_max = 0.6  W = 1.2 kips Shear capacity for wind loading;Vw = vsww1  b1 + min(vsww2,vdsww2)  b2 = 6.301 kips Vw_max / Vw = 0.19 PASS - Shear capacity for wind load exceeds maximum shear force Seismic loading: Segment 1 vertical unit deflection ;a1 = h / b1  (1 / ka + (0.04 in / (Ae  Fc_perp))  (b1 / b1_eff)) = 0.067 in/kip Segment 1 stiffness;k1 = 1 / (2  h3 / (3  E  Ae  b12) + h / (Ga  b1) + h  a1 / b1) = 3.406 kips/in Unit shear capacity, widest segment;vsws1 = vs  (1.25 - 0.125  h / b1) / 2.8 = 729.8 plf Vertical deflction under capacity load;a_Cap = h  vsws1  (1 / ka + (0.04 in / (Ae  Fc_perp))  (b1 / b1_eff)) = 0.151 in Deflection under capacity load;Cap = 2  vsws1  h3 / (3  E  Ae  b1) + vsws1  h / (Ga) + h  a_Cap / b1 = 0.661 in Segment 2 vertical unit deflection ;a1 = h / b2  (1 / ka + (0.04 in / (Ae  Fc_perp))  (b2 / b2_eff)) = 0.067 in/kip Segment 2 stiffness;k2 = 1 / (2  h3 / (3  E  Ae  b22) + h / (Ga  b2) + h  a1 / b2) = 3.406 kips/in Segment 2 unit shear at Cap;vdsws2 = Cap  k2 / b2 = 729.79 plf Segment 2 shear capacity ;vsws2 = vs  (1.25 - 0.125  h / b2) / 2.8 = 729.79 plf vdsws2 / vsws2 = 1.000 PASS - Segment shear capacity exceeds segment unit shear at Cap Maximum shear force under seismic loading;Vs_max = 0.7  Eq = 1.35 kips Shear capacity for seismic loading;Vs = vsws1  b1 + min(vsws2,vdsws2)  b2 = 4.5 kips Vs_max / Vs = 0.3 PASS - Shear capacity for seismic load exceeds maximum shear force Chord capacity for chord 1 Shear wall aspect ratio;h / b1 = 2.703 Load combination 6 Shear force for maximum tension;V = 0.7  Eq = 1.35 kips Axial force for maximum tension;P = (0.6  (D + Swt  h) - 0.7  0.2  SDS  (D + Swt  h))  b1 / 2 + 0.7  Eq_ch1 = -0.253 kips Maximum tensile force in chord;T = V  (k1 / sum(k1,k2))  h / b1_eff - P = 2.600 kips Maximum applied tensile stress;ft = T / Aen = 164 lb/in2 Design tensile stress;Ft' = Ft  CD  CMt  Ctt  CFt  Ci = 1380 lb/in2 ft / Ft' = 0.119 PASS - Design tensile stress exceeds maximum applied tensile stress Load combination 2 Shear force for maximum compression;V = 0.7  Eq = 1.35 kips Page 54 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-B Sheet no./rev. 5 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date Axial force for maximum compression;P = ((D + Swt  h) + 0.7  0.2  SDS  (D + Swt  h))  s / 2 + -1  0.7  Eq_ch1 = 0.495 kips Maximum compressive force in chord;C = V  (k1 / sum(k1,k2))  h / b1_eff + P = 2.842 kips Maximum applied compressive stress;fc = C / Ae = 148 lb/in2 Design compressive stress;Fc' = Fc  CD  CMc  Ctc  CFc  Ci  CP = 552 lb/in2 fc / Fc' = 0.267 PASS - Design compressive stress exceeds maximum applied compressive stress Design bearing compr. stress, bottom plate;Fc_perp' = Fc_perp  CMc  Ctc  Ci  Cb = 625 lb/in2 fc / Fc_perp' = 0.236 PASS - Design bearing compressive stress exceeds maximum applied bearing compressive stress Chord capacity for chord 2 Load combination 6 Shear force for maximum tension;V = 0.7  Eq = 1.35 kips Axial force for maximum tension;P = (0.6  (D + Swt  h) - 0.7  0.2  SDS  (D + Swt  h))  b1 / 2 + -1  0.7  Eq_ch2 = -0.253 kips Maximum tensile force in chord;T = V  (k1 / sum(k1,k2))  h / b1_eff - P = 2.600 kips Maximum applied tensile stress;ft = T / Aen = 164 lb/in2 Design tensile stress;Ft' = Ft  CD  CMt  Ctt  CFt  Ci = 1380 lb/in2 ft / Ft' = 0.119 PASS - Design tensile stress exceeds maximum applied tensile stress Load combination 2 Shear force for maximum compression;V = 0.7  Eq = 1.35 kips Axial force for maximum compression;P = ((D + Swt  h) + 0.7  0.2  SDS  (D + Swt  h))  s / 2 + 0.7  Eq_ch2 + DC_ch2 + 0.7  0.2  SDS  DC_ch2 = 1.29 kips Maximum compressive force in chord;C = V  (k1 / sum(k1,k2))  h / b1_eff + P = 3.637 kips Maximum applied compressive stress;fc = C / Ae = 189 lb/in2 Design compressive stress;Fc' = Fc  CD  CMc  Ctc  CFc  Ci  CP = 552 lb/in2 fc / Fc' = 0.342 PASS - Design compressive stress exceeds maximum applied compressive stress Design bearing compr. stress, bottom plate;Fc_perp' = Fc_perp  CMc  Ctc  Ci  Cb = 625 lb/in2 fc / Fc_perp' = 0.302 PASS - Design bearing compressive stress exceeds maximum applied bearing compressive stress Chord capacity for chord 3 Shear wall aspect ratio;h / b2 = 2.703 Load combination 6 Shear force for maximum tension;V = 0.7  Eq = 1.35 kips Axial force for maximum tension;P = (0.6  (D + Swt  h) - 0.7  0.2  SDS  (D + Swt  h))  b2 / 2 + 0.7  Eq_ch3 = -0.217 kips Maximum tensile force in chord;T = V  (k2 / sum(k1,k2))  h / b2_eff - P = 2.564 kips Maximum applied tensile stress;ft = T / Aen = 162 lb/in2 Design tensile stress;Ft' = Ft  CD  CMt  Ctt  CFt  Ci = 1380 lb/in2 ft / Ft' = 0.117 PASS - Design tensile stress exceeds maximum applied tensile stress Page 55 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-B Sheet no./rev. 6 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date Load combination 2 Shear force for maximum compression;V = 0.7  Eq = 1.35 kips Axial force for maximum compression;P = ((D + Swt  h) + 0.7  0.2  SDS  (D + Swt  h))  s / 2 + -1  0.7  Eq_ch3 + DC_ch3 + 0.7  0.2  SDS  DC_ch3 = 1.253 kips Maximum compressive force in chord;C = V  (k2 / sum(k1,k2))  h / b2_eff + P = 3.601 kips Maximum applied compressive stress;fc = C / Ae = 187 lb/in2 Design compressive stress;Fc' = Fc  CD  CMc  Ctc  CFc  Ci  CP = 552 lb/in2 fc / Fc' = 0.339 PASS - Design compressive stress exceeds maximum applied compressive stress Design bearing compr. stress, bottom plate;Fc_perp' = Fc_perp  CMc  Ctc  Ci  Cb = 625 lb/in2 fc / Fc_perp' = 0.299 PASS - Design bearing compressive stress exceeds maximum applied bearing compressive stress Chord capacity for chord 4 Load combination 6 Shear force for maximum tension;V = 0.7  Eq = 1.35 kips Axial force for maximum tension;P = (0.6  (D + Swt  h) - 0.7  0.2  SDS  (D + Swt  h))  b2 / 2 + -1  0.7  Eq_ch4 = -0.217 kips Maximum tensile force in chord;T = V  (k2 / sum(k1,k2))  h / b2_eff - P = 2.564 kips Maximum applied tensile stress;ft = T / Aen = 162 lb/in2 Design tensile stress;Ft' = Ft  CD  CMt  Ctt  CFt  Ci = 1380 lb/in2 ft / Ft' = 0.117 PASS - Design tensile stress exceeds maximum applied tensile stress Load combination 2 Shear force for maximum compression;V = 0.7  Eq = 1.35 kips Axial force for maximum compression;P = ((D + Swt  h) + 0.7  0.2  SDS  (D + Swt  h))  s / 2 + 0.7  Eq_ch4 = 0.459 kips Maximum compressive force in chord;C = V  (k2 / sum(k1,k2))  h / b2_eff + P = 2.806 kips Maximum applied compressive stress;fc = C / Ae = 146 lb/in2 Design compressive stress;Fc' = Fc  CD  CMc  Ctc  CFc  Ci  CP = 552 lb/in2 fc / Fc' = 0.264 PASS - Design compressive stress exceeds maximum applied compressive stress Design bearing compr. stress, bottom plate;Fc_perp' = Fc_perp  CMc  Ctc  Ci  Cb = 625 lb/in2 fc / Fc_perp' = 0.233 PASS - Design bearing compressive stress exceeds maximum applied bearing compressive stress Page 56 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-B Sheet no./rev. 7 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date Collector capacity Collector seismic design force factor;FColl = 1 Maximum shear force on wall;Vmax = max(FColl  Vs_max, Vw_max) = 1.35 kips Maximum force in collector;Pcoll = 0.446 kips Maximum applied tensile stress;ft = Pcoll / (2  As) = 42 lb/in2 Design tensile stress;Ft' = Ft  CD  CMt  Ctt  CFt  Ci = 1380 lb/in2 ft / Ft' = 0.031 PASS - Design tensile stress exceeds maximum applied tensile stress Maximum applied compressive stress;fc = Pcoll / (2  As) = 42 lb/in2 Column stability factor;CP = 1.00 Design compressive stress;Fc' = Fc  CD  CMc  Ctc  CFc  Ci  CP = 2484 lb/in2 fc / Fc' = 0.017 PASS - Design compressive stress exceeds maximum applied compressive stress Hold down force Chord 1;T1 = 2.6 kips Chord 2;T2 = 2.6 kips Chord 3;T3 = 2.564 kips Chord 4;T4 = 2.564 kips Wind load deflection Design shear force;Vw = fWserv  W = 1.2 kips Deflection limit;w_allow= h / 500 = 0.2 in Segment 1 Induced unit shear;vw = Vw  (k1 / sum(k1,k2)) / b1 = 194.59 lb/ft Anchor tension force;T = max(0 kips,vw  h  b1 / b1_eff - 0.6  (D + Swt  h)  b / 2 + 0.6  max(abs(W ch1),abs(W ch2))) = 1.489 kips Chord compression force;C = max(0 kips,vw  h  b1 / b1_eff + 0.6  (D + Swt  h)  b / 2 + 0.6  max(DC_ch1,DC_ch2) + 0.6  max(abs(W ch1),abs(W ch2))) = 3.708 kips Vertical elongation at anchor;T = T / ka = 0.031 in Vertical compression at chord;C = 0.04 in  C / (Ae  Fc_perp) = 0.012 in Total vertical deflection ;a = (T + C)  (b1 / b1_eff) = 0.055 in Page 57 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-B Sheet no./rev. 8 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date Segment 1 deflection – Eqn. 4.3-1;sww1 = 2  vw  h3 / (3  E  Ae  b1) + vw  h / (Ga) + h  a / b1 = 0.217 in sww1 / w_allow = 1.083 PASS - Shear wall deflection is less than deflection limit Segment 2 Induced unit shear;vw = Vw  (k2 / sum(k1,k2)) / b2 = 194.59 lb/ft Anchor tension force;T = max(0 kips,vw  h  b2 / b2_eff - 0.6  (D + Swt  h)  b / 2 + 0.6  max(abs(W ch3),abs(W ch4))) = 1.462 kips Chord compression force;C = max(0 kips,vw  h  b2 / b2_eff + 0.6  (D + Swt  h)  b / 2 + 0.6  max(DC_ch3,DC_ch4) + 0.6  max(abs(W ch3),abs(W ch4))) = 3.681 kips Vertical elongation at anchor;T = T / ka = 0.030 in Vertical compression at chord;C = 0.04 in  C / (Ae  Fc_perp) = 0.012 in Total vertical deflection ;a = (T + C)  (b2 / b2_eff) = 0.054 in Segment 2 deflection – Eqn. 4.3-1;sww2 = 2  vw  h3 / (3  E  Ae  b2) + vw  h / (Ga) + h  a / b2 = 0.214 in sww2 / w_allow = 1.072 PASS - Shear wall deflection is less than deflection limit Seismic deflection Design shear force;Vs = Eq = 1.928 kips Deflection limit;s_allow= 0.025  h = 2.5 in Deflection ampification factor;Cd = 4 Seismic importance factor;Ie = 1 Segment 1 Induced unit shear;vs = Vs  (k1 / sum(k1,k2)) / b1 = 312.65 lb/ft Anchor tension force;T = max(0 kips,vs  h  b1 / b1_eff - (0.6 - 0.2  SDS)  (D + Swt  h)  b / 2 + max(abs(Eq_ch1),abs(Eq_ch2))) = 3.290 kips Chord compression force;C = max(0 kips,vs  h  b1 / b1_eff + (0.6 - 0.2  SDS)  (D + Swt  h)  b / 2 + (0.6 - 0.2  SDS)  max(DC_ch1,DC_ch2) + max(abs(Eq_ch1),abs(Eq_ch2))) = 4.743 kips Vertical elongation at anchor;T = T / ka = 0.068 in Vertical compression at chord;C = 0.04 in  C / (Ae  Fc_perp) = 0.016 in Total vertical deflection ;a = (T + C)  (b1 / b1_eff) = 0.107 in Segment 1 deflection – Eqn. 4.3-1;swse1 = 2  vs  h3 / (3  E  Ae  b1) + vs  h / (Ga) + h  a / b1 = 0.398 in Amp. seis. deflection – ASCE7 Eqn. 12.8-15;sws1 = Cd  swse1 / Ie = 1.593 in sws1 / s_allow = 0.637 PASS - Shear wall deflection is less than deflection limit Segment 2 Induced unit shear;vs = Vs  (k2 / sum(k1,k2)) / b2 = 312.65 lb/ft Anchor tension force;T = max(0 kips,vs  h  b2 / b2_eff - (0.6 - 0.2  SDS)  (D + Swt  h)  b / 2 + max(abs(Eq_ch3),abs(Eq_ch4))) = 3.238 kips Chord compression force;C = max(0 kips,vs  h  b2 / b2_eff + (0.6 - 0.2  SDS)  (D + Swt  h)  b / 2 + (0.6 - 0.2  SDS)  max(DC_ch3,DC_ch4) + max(abs(Eq_ch3),abs(Eq_ch4))) = 4.691 kips Vertical elongation at anchor;T = T / ka = 0.066 in Page 58 of 108 1011 W Second St 5/1/2025 Project 1011 Job Ref. Section LINE-B Sheet no./rev. 9 Calc. by N.K Date 15/11/2024 Chk'd by Date App'd by Date Vertical compression at chord;C = 0.04 in  C / (Ae  Fc_perp) = 0.016 in Total vertical deflection ;a = (T + C)  (b2 / b2_eff) = 0.106 in Segment 2 deflection – Eqn. 4.3-1;swse2 = 2  vs  h3 / (3  E  Ae  b2) + vs  h / (Ga) + h  a / b2 = 0.394 in Amp. seis. deflection – ASCE7 Eqn. 12.8-15;sws2 = Cd  swse2 / Ie = 1.575 in sws2 / s_allow = 0.63 PASS - Shear wall deflection is less than deflection limit Page 59 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 20 Appendix E : Beam and Post Design Page 60 of 108 1011 W Second St 5/1/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2218 @ 1' 6"7656 (3.50")Passed (29%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)1462 @ 2' 5"4856 Passed (30%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)4589 @ 7' 3/4"5615 Passed (82%)1.25 1.0 D + 1.0 Lr (Alt Spans) Live Load Defl. (in)0.162 @ 7' 1/16"0.366 Passed (L/812)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.268 @ 7' 3/16"0.549 Passed (L/491)--1.0 D + 1.0 Lr (Alt Spans) System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (2L/360) and TL (2L/240). •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Column - DF 3.50"3.50"1.50"888 1330 -1085 2218/-118 Blocking 2 - Column - DF 3.50"3.50"1.50"688 1039 16/-856 1727/-101 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(non-snow: 1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 12' 7 3/4"N/A 8.2 ---- 1 - Uniform (PLF)0 to 12' 7" (Front)N/A 58.5 93.8 -76.5 Linked from: RR-1, Support 2 2 - Uniform (PLF)0 to 12' 7" (Front)N/A 58.5 93.8 -76.5 Linked from: RR-1, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF, RB-1 1 piece(s) 4 x 10 DF No.2 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 3 / 23Page 61 of 108 1011 W Second St 5/1/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2218 @ 11' 1 3/4"7656 (3.50")Passed (29%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)1462 @ 10' 2 3/4"4856 Passed (30%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)4589 @ 5' 7"5615 Passed (82%)1.25 1.0 D + 1.0 Lr (Alt Spans) Live Load Defl. (in)0.162 @ 5' 7 11/16"0.366 Passed (L/812)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.268 @ 5' 7 9/16"0.549 Passed (L/491)--1.0 D + 1.0 Lr (Alt Spans) System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (2L/360) and TL (2L/240). •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Column - DF 3.50"3.50"1.50"695 1051 16/-865 1746/-102 Blocking 2 - Column - DF 3.50"3.50"1.50"888 1330 -1085 2218/-118 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(non-snow: 1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 12' 7 3/4"N/A 8.2 ---- 1 - Uniform (PLF)0 to 12' 7" (Front)N/A 58.5 93.8 -76.5 Linked from: RR-1, Support 2 2 - Uniform (PLF)0 to 12' 7" (Front)N/A 58.5 93.8 -76.5 Linked from: RR-1, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF, RB-2 1 piece(s) 4 x 10 DF No.2 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 4 / 23Page 62 of 108 1011 W Second St 5/1/2025 Wall Height: 5'Member Height: 4' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 16 50 Passed (32%)---- Compression (lbs)2218 16234 Passed (14%)1.25 1.0 D + 1.0 Lr Plate Bearing (lbs)2218 7656 Passed (29%)--1.0 D + 1.0 Lr Lateral Reaction (lbs)33 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)28 2352 Passed (1%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)38 @ mid-span 1286 Passed (3%)1.60 1.0 D + 0.6 W Total Deflection (in)0.01 @ mid-span 0.15 Passed (L/10937)--1.0 D + 0.6 W Bending/Compression 0.03 1 Passed (3%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Member connection at both ends must be checked against an uplift of -197. •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Roof Live Wind Vertical Load Tributary Width (0.90)(non-snow: 1.25)(1.60)Comments 1 - Point (lb)N/A 888 1330 -1085 Linked from: RB-2, Support 2 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (9' 9"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 1' 4"17.6 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED ROOF, C1 1 piece(s) 4 x 4 DF No.2 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 5 / 23Page 63 of 108 1011 W Second St 5/1/2025 Post Height: 4' Design Results Actual Allowed Result LDF Load: Combination [Load Group] Slenderness 14 50 Passed (27%)---- Compression (lbs)3473 18410 Passed (19%)1.25 1.0 D + 1.0 Lr [1] Base Bearing (lbs)3473 7656 Passed (45%)--1.0 D + 1.0 Lr [1] Bending/Compression N/A 1 Passed (N/A)--N/A •Input axial load eccentricity for the design is zero •Member connection at both ends must be checked against an uplift of -338. •Applicable calculations are based on NDS. Supports Type Material Base Beam Douglas Fir-Larch Max Unbraced Length Comments Full Member Length No bracing assumed. Member Type : Free Standing Post Building Code : IBC 2021 Design Methodology : ASD Dead Roof Live Wind Vertical Loads (0.90)(non-snow: 1.25)(1.60)Comments 1 - Point (lb)688 1039 16/-856 Linked from: RB-1, Support 2 2 - Point (lb)695 1051 16/-865 Linked from: RB-2, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED ROOF, C2 1 piece(s) 4 x 4 DF No.2 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 6 / 23Page 64 of 108 1011 W Second St 5/1/2025 Wall Height: 12'Member Height: 11' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 40 50 Passed (80%)---- Compression (lbs)2218 3552 Passed (62%)1.25 1.0 D + 1.0 Lr Plate Bearing (lbs)2218 7656 Passed (29%)--1.0 D + 1.0 Lr Lateral Reaction (lbs)75 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)71 2352 Passed (3%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)217 @ mid-span 1286 Passed (17%)1.60 1.0 D + 0.6 W Total Deflection (in)0.18 @ mid-span 0.39 Passed (L/757)--1.0 D + 0.6 W Bending/Compression 0.36 1 Passed (36%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Member connection at both ends must be checked against an uplift of -197. •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 11' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Roof Live Wind Vertical Load Tributary Width (0.90)(non-snow: 1.25)(1.60)Comments 1 - Point (lb)N/A 888 1330 -1085 Linked from: RB-1, Support 1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (9' 9"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 1' 4"16.0 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED ROOF, C3 1 piece(s) 4 x 4 DF No.2 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 7 / 23Page 65 of 108 1011 W Second St 5/1/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) [Group] Member Reaction (lbs)2014 @ 2"12031 (3.50")Passed (17%)--1.0 D + 1.0 Lr (All Spans) [1] Shear (lbs)1981 @ 1' 3"8960 Passed (22%)1.25 1.0 D + 1.0 Lr (All Spans) [1] Moment (Ft-lbs)16414 @ 8' 10"16870 Passed (97%)1.25 1.0 D + 1.0 Lr (All Spans) [1] Live Load Defl. (in)0.374 @ 8' 11 5/8"0.590 Passed (L/568)--1.0 D + 1.0 Lr (All Spans) [1] Total Load Defl. (in)0.675 @ 8' 11 11/16"0.885 Passed (L/315)--1.0 D + 1.0 Lr (All Spans) [1] System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •A 1% decrease in the moment capacity has been added to account for lateral stability. •Lumber grading provisions must be extended over the length of the member per NDS 4.2.5.5. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Column - DF 3.50"3.50"1.50"947 120 1067 16/-879 2014 None 2 - Column - DF 3.50"3.50"1.50"918 120 1023 16/-842 1940 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' o/c Bottom Edge (Lu)End Bearing Points Dead Floor Live Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(non-snow: 1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 18' 1/2"N/A 16.0 ------ 1 - Uniform (PSF)0 to 18' 1/2" (Front)1' 4"8.0 10.0 --2 CEILING JOISTS 2 - Point (lb)8' 10" (Top)N/A 1383 -2090 32/-1721 Linked from: C2, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED CEILING, B-1 1 piece(s) 6 x 12 DF No.1 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 9 / 23Page 66 of 108 1011 W Second St 5/1/2025 Wall Height: 4'Member Height: 3' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination [Load Group] Slenderness 12 50 Passed (25%)---- Compression (lbs)2014 19572 Passed (10%)1.25 1.0 D + 1.0 Lr [1] Plate Bearing (lbs)2014 7656 Passed (26%)--1.0 D + 1.0 Lr [1] Lateral Reaction (lbs)26 ----1.60 1.0 D + 0.6 W [1] Lateral Shear (lbs)21 2352 Passed (1%)1.60 1.0 D + 0.6 W [1] Lateral Moment (ft-lbs)23 @ mid-span 1286 Passed (2%)1.60 1.0 D + 0.6 W [1] Total Deflection (in)0.00 @ mid-span 0.12 Passed (L/22715)--1.0 D + 0.6 W [1] Bending/Compression 0.02 1 Passed (2%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr [1] •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 3' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(non-snow: 1.25)(1.60)Comments 1 - Point (lb)N/A 947 120 1067 16/-879 Linked from: B-1, Support 1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 1' 4"17.6 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CEILING, C4 1 piece(s) 4 x 4 DF No.2 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 10 / 23Page 67 of 108 1011 W Second St 5/1/2025 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination [Load Group] Slenderness 26 50 Passed (52%)---- Compression (lbs)1941 7787 Passed (25%)1.25 1.0 D + 1.0 Lr [1] Plate Bearing (lbs)1941 7656 Passed (25%)--1.0 D + 1.0 Lr [1] Lateral Reaction (lbs)52 ----1.60 1.0 D + 0.6 W [1] Lateral Shear (lbs)48 2352 Passed (2%)1.60 1.0 D + 0.6 W [1] Lateral Moment (ft-lbs)98 @ mid-span 1286 Passed (8%)1.60 1.0 D + 0.6 W [1] Total Deflection (in)0.04 @ mid-span 0.25 Passed (L/2541)--1.0 D + 0.6 W [1] Bending/Compression 0.12 1 Passed (12%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr [1] •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(non-snow: 1.25)(1.60)Comments 1 - Point (lb)N/A 918 120 1023 16/-842 Linked from: B-1, Support 2 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 1' 4"16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CEILING, C5 1 piece(s) 4 x 4 DF No.2 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 11 / 23Page 68 of 108 1011 W Second St 5/1/2025 Wall Height: 9' 4"Member Height: 8' 11 1/2"Tributary Width: 7' Design Results Actual Allowed Result LDF Load: Combination Slenderness 31 50 Passed (61%)---- Compression (lbs)1552 9763 Passed (16%)1.25 1.0 D + 1.0 Lr Plate Bearing (lbs)1552 12031 Passed (13%)--1.0 D + 1.0 Lr Lateral Reaction (lbs)295 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)265 3696 Passed (7%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)660 @ mid-span 3010 Passed (22%)1.60 1.0 D + 0.6 W Total Deflection (in)0.08 @ mid-span 0.30 Passed (L/1328)--1.0 D + 0.6 W Bending/Compression 0.23 1 Passed (23%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 8' 11 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)4 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)4 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(non-snow: 1.25)(1.60)Comments 1 - Point (lb)N/A 792 41 760 -554 Linked from: HDR-1, Support 1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 7'15.7 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CEILING, C6 1 piece(s) 4 x 6 DF No.1 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 12 / 23Page 69 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 21 Appendix F : Header, Jack Stud and King Stud Design Page 70 of 108 1011 W Second St 5/1/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1552 @ 0 3281 (1.50")Passed (47%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)1479 @ 1' 3/4"5906 Passed (25%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)8077 @ 6'8459 Passed (95%)1.25 1.0 D + 1.0 Lr (All Spans) Vert Live Load Defl. (in)0.134 @ 6' 1 3/16"0.245 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Vert Total Load Defl. (in)0.257 @ 6' 1 3/16"0.306 Passed (L/572)--1.0 D + 1.0 Lr (All Spans) Lat Member Reaction (lbs)342 @ 12' 3"N/A Passed (N/A)1.60 1.0 D + 0.6 W Lat Shear (lbs)319 @ 5"7560 Passed (4%)1.60 1.0 D + 0.6 W Lat Moment (Ft-lbs)1047 @ mid-span 3706 Passed (28%)1.60 1.0 D + 0.6 W Lat Deflection (in)0.290 @ mid-span 0.408 Passed (L/507)--1.0 D + 0.6 W Bi-Axial Bending 0.78 1.00 Passed (78%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/600) and TL (L/480). •Lateral deflection criteria: Wind (L/360) •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Trimmer - DF 1.50"1.50"1.50"792 41 760 -554 1552 None 2 - Trimmer - DF 1.50"1.50"1.50"774 41 733 -531 1507 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)12' 3" o/c Bottom Edge (Lu)12' 3" o/c Lateral Connections Supports Plate Size Plate Material Connector Type/Model Quantity Nailing Left 2X Douglas Fir-Larch Nails 10d (0.128" x 3") (End)4 Right 2X Douglas Fir-Larch Nails 10d (0.128" x 3") (End)4 Dead Floor Live Roof Live Wind Vertical Loads Location Tributary Width (0.90)(1.00)(non-snow: 1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 12' 3"N/A 10.0 ------ 1 - Uniform (PSF)0 to 12' 3"2'16.0 ---WALL 2 - Uniform (PSF)0 to 12' 3"8"8.0 10.0 --CJ-1 3 - Uniform (PSF)0 to 12' 3"8"12.0 -20.0 -RR-1 4 - Point (lb)6'N/A 888 -1330 -1085 Linked from: C1, Support 1 Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 6'15.5 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED CEILING, HDR-1 1 piece(s) 4 x 12 DF No.1 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 13 / 23Page 71 of 108 1011 W Second St 5/1/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)482 @ 0 3281 (1.50")Passed (15%)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Shear (lbs)289 @ 7"2888 Passed (10%)1.25 1.0 D + 0.75 L + 0.75 Lr (All Spans) Moment (Ft-lbs)352 @ 1' 5 1/2"2151 Passed (16%)1.25 1.0 D + 0.75 L + 0.75 Lr (All Spans) Vert Live Load Defl. (in)0.003 @ 1' 5 1/2"0.097 Passed (L/999+)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Vert Total Load Defl. (in)0.007 @ 1' 5 1/2"0.146 Passed (L/999+)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Lat Member Reaction (lbs)72 @ 2' 11"N/A Passed (N/A)1.60 1.0 D + 0.6 W Lat Shear (lbs)52 @ 5"3696 Passed (1%)1.60 1.0 D + 0.6 W Lat Moment (Ft-lbs)53 @ mid-span 1839 Passed (3%)1.60 1.0 D + 0.6 W Lat Deflection (in)0.002 @ mid-span 0.097 Passed (L/999+)--1.0 D + 0.6 W Bi-Axial Bending 0.13 1.00 Passed (13%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Lateral deflection criteria: Wind (L/360) •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Trimmer - DF 1.50"1.50"1.50"249 132 178 -142 482 None 2 - Trimmer - DF 1.50"1.50"1.50"249 132 178 -142 482 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)2' 11" o/c Bottom Edge (Lu)2' 11" o/c Lateral Connections Supports Plate Size Plate Material Connector Type/Model Quantity Nailing Left 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Right 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Dead Floor Live Roof Live Wind Vertical Loads Location Tributary Width (0.90)(1.00)(non-snow: 1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 2' 11"N/A 4.9 ------ 1 - Uniform (PSF)0 to 2' 11"1'16.0 ---WALL 2 - Uniform (PLF)0 to 2' 11"N/A 77.3 -122.3 -97.5 Linked from: RR-1, Support 1 3 - Uniform (PLF)0 to 2' 11"N/A 72.8 90.8 --Linked from: CJ-1, Support 1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Effective Wind Area determined using full member span and trib. width. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 4' 9 5/8"17.3 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED CEILING, HDR-2 1 piece(s) 4 x 6 DF No.2 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 15 / 23Page 72 of 108 1011 W Second St 5/1/2025 Wall Height: 6' 10"Member Height: 6' 5 1/2"Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)482 2309 Passed (21%)1.25 1.0 D + 0.75 L + 0.75 Lr Plate Bearing (lbs)482 3281 Passed (15%)--1.0 D + 0.75 L + 0.75 Lr Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(non-snow: 1.25)(1.60)Comments 1 - Point (lb)N/A 249 132 178 -142 Linked from: HDR-2, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CEILING, JACK-2 1 piece(s) 2 x 4 DF No.2 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 17 / 23Page 73 of 108 1011 W Second St 5/1/2025 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 2' 4 13/16" Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)0 2342 Passed (0%)1.60 1.0 D + 0.6 W Plate Bearing (lbs)0 3281 Passed (0%)--1.0 D + 0.6 W Lateral Reaction (lbs)93 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)86 1008 Passed (9%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)177 @ mid-span 532 Passed (33%)1.60 1.0 D + 0.6 W Total Deflection (in)0.15 @ mid-span 0.25 Passed (L/605)--1.0 D + 0.6 W Bending/Compression 0.33 1 Passed (33%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. An error occurred while attempting to execute the subreport. • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 2' 4 13/16"16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CEILING, KING-2 1 piece(s) 2 x 4 DF No.2 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 18 / 23Page 74 of 108 1011 W Second St 5/1/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) [Group] Member Reaction (lbs)1729 @ 0 3281 (1.50")Passed (53%)--1.0 D + 0.75 L + 0.75 Lr (All Spans) [1] Shear (lbs)1494 @ 8 3/4"3806 Passed (39%)1.25 1.0 D + 1.0 Lr (All Spans) [1] Moment (Ft-lbs)2822 @ 2'3737 Passed (76%)1.25 1.0 D + 1.0 Lr (All Spans) [1] Vert Live Load Defl. (in)0.022 @ 2' 1 3/8"0.142 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) [1] Vert Total Load Defl. (in)0.044 @ 2' 1 7/16"0.213 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) [1] Lat Member Reaction (lbs)56 @ 4' 3"N/A Passed (N/A)1.60 1.0 D + 0.6 W [1] Lat Shear (lbs)45 @ 5"4872 Passed (1%)1.60 1.0 D + 0.6 W [1] Lat Moment (Ft-lbs)59 @ mid-span 2425 Passed (2%)1.60 1.0 D + 0.6 W [1] Lat Deflection (in)0.003 @ mid-span 0.142 Passed (L/999+)--1.0 D + 0.6 W [1] Bi-Axial Bending 0.58 1.00 Passed (58%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr [1] System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Lateral deflection criteria: Wind (L/360) •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Trimmer - DF 1.50"1.50"1.50"893 290 825 -673 1729 None 2 - Trimmer - DF 1.50"1.50"1.50"838 283 762 -621 1621 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)4' 3" o/c Bottom Edge (Lu)4' 3" o/c Lateral Connections Supports Plate Size Plate Material Connector Type/Model Quantity Nailing Left 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Right 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Dead Floor Live Roof Live Wind Vertical Loads Location Tributary Width (0.90)(1.00)(non-snow: 1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 4' 3"N/A 6.4 ------ 1 - Uniform (PSF)0 to 4' 3"1'16.0 ---Default Load 2 - Uniform (PLF)0 to 4' 3"N/A 84.8 106.5 --Linked from: CJ-1, Support 1 3 - Uniform (PLF)0 to 4' 3"N/A 77.3 -122.3 -97.5 Linked from: RR-1, Support 1 4 - Point (lb)2'N/A 947 120 1067 16/-879 Linked from: C4, Support 1 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED CEILING, HDR-3 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 19 / 23Page 75 of 108 1011 W Second St 5/1/2025 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 2' 6"17.5 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 20 / 23Page 76 of 108 1011 W Second St 5/1/2025 Wall Height: 6' 5"Member Height: 6' 1/2"Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 21 50 Passed (41%)---- Compression (lbs)1729 8272 Passed (21%)1.25 1.0 D + 0.75 L + 0.75 Lr Plate Bearing (lbs)1729 6563 Passed (26%)--1.0 D + 0.75 L + 0.75 Lr Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.02 @ mid-span 0.20 Passed (L/3656)--1.0 D + 0.75 L + 0.75 Lr Bending/Compression 0.16 1 Passed (16%)1.25 1.0 D + 0.75 L + 0.75 Lr •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for this design is 16.67% of applicable member side dimension. •Applicable calculations are based on NDS. •The column stability factor (Kf = 0.6) applied to this design assumes nailed built-up columns per NDS section 15.3.3. For Weyerhaeuser ELP products refer to the U.S. Wall Guide for multiple-member connection requirements. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(non-snow: 1.25)(1.60)Comments 1 - Point (lb)N/A 893 290 825 -673 Linked from: HDR-3, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CEILING, JACK-3 2 piece(s) 2 x 4 DF No.2 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 21 / 23Page 77 of 108 1011 W Second St 5/1/2025 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 3' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)0 2342 Passed (0%)1.60 1.0 D + 0.6 W Plate Bearing (lbs)0 3281 Passed (0%)--1.0 D + 0.6 W Lateral Reaction (lbs)115 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)106 1008 Passed (11%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)219 @ mid-span 532 Passed (41%)1.60 1.0 D + 0.6 W Total Deflection (in)0.19 @ mid-span 0.25 Passed (L/489)--1.0 D + 0.6 W Bending/Compression 0.41 1 Passed (41%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. An error occurred while attempting to execute the subreport. • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 3'16.7 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CEILING, KING-3 1 piece(s) 2 x 4 DF No.2 ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 22 / 23Page 78 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 22 Appendix G : Joist Design Page 79 of 108 1011 W Second St 5/1/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)191 @ 10' 5 1/4"1406 (1.50")Passed (14%)--1.0 D + 1.0 Lr (Alt Spans) Shear (lbs)169 @ 2' 2 5/8"1631 Passed (10%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)418 @ 6' 11/16"1700 Passed (25%)1.25 1.0 D + 1.0 Lr (Alt Spans) Live Load Defl. (in)0.054 @ 5' 11 7/8"0.314 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.087 @ 6'0.471 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 4/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (2L/360) and TL (2L/240). •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Beveled Plate - DF 3.50"3.50"1.50"103 163 -130 265/-16 Blocking 2 - Hanger on 7 1/4" DF beam 3.50"Hanger¹1.50"78 125 -102 203/-14 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LRU26Z 1.94"N/A 4-10dx1.5 5-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Roof Live Wind Vertical Load Location (Side)Spacing (0.90)(non-snow: 1.25)(1.60)Comments 1 - Uniform (PSF)0 to 10' 8 3/4"16"12.0 20.0 -16.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.Member Length : 11' 2 7/16" MEMBER REPORT PASSED ROOF, RR-1 1 piece(s) 2 x 8 DF No.2 @ 16" OC ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 2 / 23Page 80 of 108 1011 W Second St 5/1/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)218 @ 2 1/2"3281 (3.50")Passed (7%)--1.0 D + 1.0 L (All Spans) Shear (lbs)197 @ 10 3/4"1305 Passed (15%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)945 @ 9' 1"1098 Passed (86%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.391 @ 9' 1"0.592 Passed (L/545)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.703 @ 9' 1"0.887 Passed (L/303)--1.0 D + 1.0 L (All Spans) TJ-Pro™ Rating N/A N/A N/A --N/A System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •A 15% increase in the moment capacity has been added to account for repetitive member usage. •A 19.3% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. •No composite action between deck and joist was considered in analysis. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"97 121 218 Blocking 2 - Stud wall - DF 3.50"3.50"1.50"97 121 218 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' o/c Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 18' 2"16"8.0 10.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED CEILING, CJ-1 1 piece(s) 2 x 8 DF No.2 @ 16" OC ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 8 / 23Page 81 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 23 Appendix H : Stud Wall Design Page 82 of 108 1011 W Second St 5/1/2025 Wall Height: 8'Member Height: 7' 7 1/2"O. C. Spacing: 16.00" Design Results Actual Allowed Result LDF Load: Combination Slenderness 40 50 Passed (80%)---- Compression (lbs)413 1512 Passed (27%)1.25 1.0 D + 0.75 L + 0.75 Lr Plate Bearing (lbs)413 2789 Passed (15%)--1.0 D + 0.75 L + 0.75 Lr Lateral Reaction (lbs)52 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)48 1008 Passed (5%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)98 @ mid-span 594 Passed (17%)1.60 1.0 D + 0.6 W Total Deflection (in)0.08 @ mid-span 0.25 Passed (L/1089)--1.0 D + 0.6 W Bending/Compression 0.19 1 Passed (19%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. •A bearing area factor of 1.25 has been applied to base plate bearing capacity. •A 15% increase in the moment capacity has been added to account for repetitive member usage. Supports Type Material Top Dbl 2X Spruce-Pine-Fir Base 2X Spruce-Pine-Fir Max Unbraced Length Comments 5' System : Wall Member Type : Stud Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Floor Live Roof Live Wind Vertical Loads Spacing (0.90)(1.00)(non-snow: 1.25)(1.60)Comments 1 - Point (lb)N/A 103 -163 -130 Linked from: RR-1, Support 1 2 - Point (lb)N/A 97 121 --Linked from: CJ-1, Support 1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Spacing (1.60)Comments 1 - Uniform (PSF)Full Length 16.00"16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CEILING, Stud Wall-1 1 piece(s) 2 x 4 DF No.2 @ 16" OC ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC negar kordbache sazan (443) 942-2153 negarkordbache@gmail.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: 1011 W 2nd St Santa Ana, Ca 92703 Page 23 / 23Page 83 of 108 1011 W Second St 5/1/2025 1011 W 2nd  U.S. Office: Canada Office: 2610 Vista Del Oro, Newport Beach, CA 92660 550 HWY 7, Unit 315, Richmond Hill, ON L4B 3Z4  +1 949-822-1913 +1 289-597-0455 24 Appendix I : Foundation Design Page 84 of 108 1011 W Second St 5/1/2025 Sazan Project: 1011 Job Ref. 1 Fondansion: 1 Sheet no./rev R1 Calc. by N.K Date 2023/02/02 Chk'd by Date 2023/02/02 App'd by Date 2023/02/02 FOOTING ANALYSIS In accordance with ACI318-19 Overall design status PASS Overall design utilisation; 0.545 Description Unit Applied Resisting Utilization Result Soil bearing Ksf 818.03 1500 0.545 Pass Moment, positive kip_ft 8.92 19.08 0.468 Pass Moment, negative kip_ft 0 25.45 0 Pass Shear kip 2.237 19.08 0.117 Pass Pad footing details Length of footing L=22.1 ft Width of footing b=12 in Footing area A=1.84 ft2 Depth of footing H=24 in Density of concrete mass=145 lb/ft3 load case : Eh , W , D , L , Lr Point loads P (Kip) a (ft) loadCase -0.97 0.5 Eh -0.85 0.5 W 0.97 21.5 Eh 0.85 21.5 W 0.893 8.9 D 0.29 8.9 L 0.825 8.9 Lr -0.673 8.9 W 0.893 13 D 0.29 13 L 0.825 13 Lr Page 85 of 108 1011 W Second St 5/1/2025 -0.673 13 W 0.249 17.8 D 0.132 17.8 L 0.178 17.8 Lr -0.142 17.8 W 0.249 20 D 0.132 20 L 0.178 20 Lr -0.142 20 W Eh W Page 86 of 108 1011 W Second St 5/1/2025 D L Lr Distributed Loads W1 (Kip) W2 (Kip) a (ft) b (ft) loadCase 0.318 0.318 0 22.1 D Page 87 of 108 1011 W Second St 5/1/2025 0.190 0.190 0 22.1 Lr 0.095 0.095 0 22.1 L Footing analysis for soil and stability Load combinations per ASCE 7-16 ASD01: +D ASD02: +D+L ASD03: +D+Lr ASD04: +D+S ASD05: +D+0.75L+0.75Lr ASD06: +D+0.75L+0.75S ASD07: +D+0.6W ASD08: +D+0.75L+0.45W+0.75Lr ASD09: +D+0.75L+0.45W+0.75S ASD10: +D+0.15D+0.7Eh ASD11: +D+0.11D+0.525Eh+0.75L+0.75S ASD12: +0.6D-0.15D+0.7Eh ASD13: +D+0.15D-0.7Eh ASD14: +D+0.11D-0.525Eh+0.75L+0.75S ASD15: +0.6D-0.15D-0.7Eh Load Combinations q max q min q allowed Check Bearing Stress L/6 e L' ASD01 465.74 376.24 1500 OK 3.68 0.4 0 ASD02 623.25 484.9 1500 OK 3.68 0.47 0 ASD03 777.95 625.13 1500 OK 3.68 0.41 0 ASD04 465.74 376.24 1500 OK 3.68 0.4 0 ASD05 818.03 644.4 1500 OK 3.68 0.45 0 ASD06 583.87 457.73 1500 OK 3.68 0.46 0 ASD07 537.62 215.85 1995 OK 3.68 1.58 0 ASD08 871.94 524.12 1995 OK 3.68 0.93 0 ASD09 637.78 337.44 1995 OK 3.68 1.14 0 ASD10 710.77 257.5 1995 OK 3.68 1.73 0 ASD11 766.48 367.74 1995 OK 3.68 1.3 0 ASD12 385.17 0 1995 OK 3.68 3.8 0.36 ASD13 607.84 360.43 1995 OK 3.68 -0.93 0 ASD14 630.49 503.73 1995 OK 3.68 -0.4 0 Page 88 of 108 1011 W Second St 5/1/2025 ASD15 344.48 34.41 1995 OK 3.68 -3 0 ASD05 FOOTING DESIGN In accordance with ACI318-19 Material details Compressive strength of concrete f'c = 4500 psi Concrete type Normal Analysis and design of concrete footing Load combinations per ASCE 7-16 LRFD01: +1.4D LRFD02: +1.2D+1.6L+0.5Lr LRFD03: +1.2D+1.6Lr+L LRFD04: +1.2D+1.6Lr+0.5W LRFD05: +1.2D+1.6Lr-0.5W LRFD06: +1.2D+1.6S+L LRFD07: +1.2D+1.6S+0.5W LRFD08: +1.2D+1.6S-0.5W LRFD09: +1.2D+W+L+0.5Lr LRFD10: +1.2D-W+L+0.5Lr LRFD11: +1.2D+W+L+0.5S LRFD12: +1.2D-W+L+0.5S LRFD13: +1.2D+Eh+L+0.2S+0.21D LRFD14: +1.2D-Eh+L+0.2S+0.21D LRFD15: +0.9D+Eh-0.21D LRFD16: +0.9D-Eh-0.21D LRFD17: +0.9D+W LRFD18: +0.9D Combination 2 results: Envelop Page 89 of 108 1011 W Second St 5/1/2025 X Vmax Vmin Mmax Mmin φMn_Pos φMn_Neg φVn Check V Check M 8.85 2.23714 - 0.222845 8.31 0 19.08 25.45 14.17 Ok Ok 13 0 - 2.070485 8.92 -0.32 19.08 25.45 14.17 Ok Ok 13 0 - 2.070485 8.92 -0.32 19.08 25.45 14.17 Ok Ok 3.9 0.779515 0 2.43 -1.29 19.08 25.45 14.17 Ok Ok H =24 h =22 bf =24 bw =12 tf =5 Yt = (h✕bw✕h/2+Max(0,(bf-bw)✕tf✕tf/2))/(h✕bw+Max(0,(bf-bw)✕tf))= 9.43 in Yb = h-Yt12.57 in I = bw✕h✕h✕h/12+h✕bw✕(h/2-Yt)✕(h/2-Yt)+Max(0,(bf-bw))✕tf✕tf✕tf/12+Max(0,(bf- bw))✕tf✕(tf/2-Yt)✕(tf/2-Yt)= 14305.22 in4 St = I/Yt= 1517.65 in3 Sb = I/Yb= 1137.68 in3 fr = 5√fc= 335.41 psi φMn_Pos=0.6✕(Min(St✕0.85✕f'c, Sb✕fr)/12000) φMn_Neg=0.6✕(Min(St✕fr,Sb✕0.85✕f'c)/12000) φVn=0.6 * (4/3*√fc*bw*h/1000) Page 90 of 108 1011 W Second St 5/1/2025 Sazan Project: 1011 Job Ref. 2 Fondansion: 2 Sheet no./rev R1 Calc. by N.K Date 2023/02/02 Chk'd by Date 2023/02/02 App'd by Date 2023/02/02 FOOTING ANALYSIS In accordance with ACI318-19 Overall design status PASS Overall design utilisation; 0.41 Description Unit Applied Resisting Utilization Result Soil bearing Ksf 614.37 1500 0.41 Pass Moment, positive kip_ft 8.75 19.08 0.459 Pass Moment, negative kip_ft 0 25.45 0 Pass Shear kip 1.727 19.08 0.091 Pass Pad footing details Length of footing L=22.1 ft Width of footing b=12 in Footing area A=1.84 ft2 Depth of footing H=24 in Density of concrete mass=145 lb/ft3 load case : Eh , W , D , L , Lr Point loads P (Kip) a (ft) loadCase -0.78 0.5 Eh -0.7 0.5 W 0.78 21.5 Eh 0.7 21.5 W 0.918 11 D 0.12 11 L 1.023 11 Lr -0.842 11 W Page 91 of 108 1011 W Second St 5/1/2025 Eh W D Page 92 of 108 1011 W Second St 5/1/2025 L Lr Distributed Loads W1 (Kip) W2 (Kip) a (ft) b (ft) loadCase 0.318 0.318 0 22.1 D 0.190 0.190 0 22.1 Lr 0.095 0.095 0 22.1 L Footing analysis for soil and stability Load combinations per ASCE 7-16 ASD01: +D ASD02: +D+L ASD03: +D+Lr ASD04: +D+S ASD05: +D+0.75L+0.75Lr ASD06: +D+0.75L+0.75S Page 93 of 108 1011 W Second St 5/1/2025 ASD07: +D+0.6W ASD08: +D+0.75L+0.45W+0.75Lr ASD09: +D+0.75L+0.45W+0.75S ASD10: +D+0.15D+0.7Eh ASD11: +D+0.11D+0.525Eh+0.75L+0.75S ASD12: +0.6D-0.15D+0.7Eh ASD13: +D+0.15D-0.7Eh ASD14: +D+0.11D-0.525Eh+0.75L+0.75S ASD15: +0.6D-0.15D-0.7Eh Load Combinations q max q min q allowed Check Bearing Stress L/6 e L' ASD01 360.82 357.54 1500 OK 3.68 -0.01 0 ASD02 461.54 457.46 1500 OK 3.68 -0.01 0 ASD03 598.17 592.34 1500 OK 3.68 -0.01 0 ASD04 360.82 357.54 1500 OK 3.68 -0.01 0 ASD05 614.37 608.58 1500 OK 3.68 -0.01 0 ASD06 436.36 432.48 1500 OK 3.68 -0.01 0 ASD07 443.34 229.3 1995 OK 3.68 1.18 0 ASD08 672.93 515.73 1995 OK 3.68 0.5 0 ASD09 496.83 337.72 1995 OK 3.68 0.71 0 ASD10 552.02 274.09 1995 OK 3.68 1.25 0 ASD11 577.45 370.41 1995 OK 3.68 0.81 0 ASD12 301.75 21.51 1995 OK 3.68 3.2 0 ASD13 555.8 270.31 1995 OK 3.68 -1.26 0 ASD14 581.69 366.17 1995 OK 3.68 -0.83 0 ASD15 303.23 20.03 1995 OK 3.68 -3.21 0 ASD05 FOOTING DESIGN In accordance with ACI318-19 Material details Compressive strength of concrete f'c = 4500 psi Concrete type Normal Page 94 of 108 1011 W Second St 5/1/2025 Analysis and design of concrete footing Load combinations per ASCE 7-16 LRFD01: +1.4D LRFD02: +1.2D+1.6L+0.5Lr LRFD03: +1.2D+1.6Lr+L LRFD04: +1.2D+1.6Lr+0.5W LRFD05: +1.2D+1.6Lr-0.5W LRFD06: +1.2D+1.6S+L LRFD07: +1.2D+1.6S+0.5W LRFD08: +1.2D+1.6S-0.5W LRFD09: +1.2D+W+L+0.5Lr LRFD10: +1.2D-W+L+0.5Lr LRFD11: +1.2D+W+L+0.5S LRFD12: +1.2D-W+L+0.5S LRFD13: +1.2D+Eh+L+0.2S+0.21D LRFD14: +1.2D-Eh+L+0.2S+0.21D LRFD15: +0.9D+Eh-0.21D LRFD16: +0.9D-Eh-0.21D LRFD17: +0.9D+W LRFD18: +0.9D Combination 2 results: Envelop X Vmax Vmin Mmax Mmin φMn_Pos φMn_Neg φVn Check V Check M 10.95 1.72714 - 0.302845 8.66 0 19.08 25.45 14.17 Ok Ok 11 0.0154855 -1.42286 8.75 0 19.08 25.45 14.17 Ok Ok 11 0.0154855 -1.42286 8.75 0 19.08 25.45 14.17 Ok Ok 17.4 0.037155 -0.68286 2.47 -1.15 19.08 25.45 14.17 Ok Ok Page 95 of 108 1011 W Second St 5/1/2025 H =24 h =22 bf =24 bw =12 tf =5 Yt = (h✕bw✕h/2+Max(0,(bf-bw)✕tf✕tf/2))/(h✕bw+Max(0,(bf-bw)✕tf))= 9.43 in Yb = h-Yt12.57 in I = bw✕h✕h✕h/12+h✕bw✕(h/2-Yt)✕(h/2-Yt)+Max(0,(bf-bw))✕tf✕tf✕tf/12+Max(0,(bf- bw))✕tf✕(tf/2-Yt)✕(tf/2-Yt)= 14305.22 in4 St = I/Yt= 1517.65 in3 Sb = I/Yb= 1137.68 in3 fr = 5√fc= 335.41 psi φMn_Pos=0.6✕(Min(St✕0.85✕f'c, Sb✕fr)/12000) φMn_Neg=0.6✕(Min(St✕fr,Sb✕0.85✕f'c)/12000) φVn=0.6 * (4/3*√fc*bw*h/1000) Page 96 of 108 1011 W Second St 5/1/2025 Sazan Project: 1011 Job Ref. A Fondansion: A Sheet no./rev R1 Calc. by N.K Date 2023/02/02 Chk'd by Date 2023/02/02 App'd by Date 2023/02/02 FOOTING ANALYSIS In accordance with ACI318-19 Overall design status PASS Overall design utilisation; 0.442 Description Unit Applied Resisting Utilization Result Soil bearing Ksf 881.8 1995 0.442 Pass Moment, positive kip_ft 8.25 23.85 0.346 Pass Moment, negative kip_ft 0 27.93 0 Pass Shear kip 2.191 23.85 0.092 Pass Pad footing details Length of footing L=18.16 ft Width of footing b=16 in Footing area A=2.02 ft2 Depth of footing H=24 in Density of concrete mass=145 lb/ft3 load case : Eh , W , Lr , D , L Point loads P (Kip) a (ft) loadCase -1.7 0.5 Eh -1.72 0.5 W 1.7 17.5 Eh 1.72 17.5 W -1.08 9 W 1.3 9 Lr 0.89 9 D Page 97 of 108 1011 W Second St 5/1/2025 Eh W Lr Page 98 of 108 1011 W Second St 5/1/2025 D Distributed Loads W1 (Kip) W2 (Kip) a (ft) b (ft) loadCase 0.2186 0.2186 0 18.16 D 0.44 0.44 0 18.16 D 0.0133 0.0133 0 18.16 L 0.0266 0.0266 0 18.16 Lr Footing analysis for soil and stability Load combinations per ASCE 7-16 ASD01: +D ASD02: +D+L ASD03: +D+Lr ASD04: +D+S ASD05: +D+0.75L+0.75Lr ASD06: +D+0.75L+0.75S ASD07: +D+0.6W ASD08: +D+0.75L+0.45W+0.75Lr ASD09: +D+0.75L+0.45W+0.75S ASD10: +D+0.14D+0.7Eh ASD11: +D+0.11D+0.525Eh+0.75L+0.75S ASD12: +0.6D-0.14D+0.7Eh ASD13: +D+0.14D-0.7Eh ASD14: +D+0.11D-0.525Eh+0.75L+0.75S Page 99 of 108 1011 W Second St 5/1/2025 ASD15: +0.6D-0.14D-0.7Eh Load Combinations q max q min q allowed Check Bearing Stress L/6 e L' ASD01 531.37 530.86 1500 OK 3.03 -0.01 0 ASD02 541.37 540.82 1500 OK 3.03 -0.01 0 ASD03 605.89 603.65 1500 OK 3.03 -0.01 0 ASD04 531.37 530.86 1500 OK 3.03 -0.01 0 ASD05 594.6 593.09 1500 OK 3.03 -0.01 0 ASD06 538.87 538.33 1500 OK 3.03 -0.01 0 ASD07 744.7 264 1995 OK 3.03 1.44 0 ASD08 753.09 394.46 1995 OK 3.03 0.94 0 ASD09 698.87 338.19 1995 OK 3.03 1.05 0 ASD10 881.8 329.14 1995 OK 3.03 1.38 0 ASD11 804.35 389.7 1995 OK 3.03 1.04 0 ASD12 522.29 0 1995 OK 3.03 3.42 1.17 ASD13 881.23 329.71 1995 OK 3.03 -1.39 0 ASD14 803.76 390.29 1995 OK 3.03 -1.06 0 ASD15 523.31 0 1995 OK 3.03 -3.43 16.96 ASD10 FOOTING DESIGN In accordance with ACI318-19 Material details Compressive strength of concrete f'c = 4500 psi Concrete type Normal Analysis and design of concrete footing Load combinations per ASCE 7-16 LRFD01: +1.4D LRFD02: +1.2D+1.6L+0.5Lr LRFD03: +1.2D+1.6Lr+L LRFD04: +1.2D+1.6Lr+0.5W LRFD05: +1.2D+1.6Lr-0.5W LRFD06: +1.2D+1.6S+L Page 100 of 108 1011 W Second St 5/1/2025 LRFD07: +1.2D+1.6S+0.5W LRFD08: +1.2D+1.6S-0.5W LRFD09: +1.2D+W+L+0.5Lr LRFD10: +1.2D-W+L+0.5Lr LRFD11: +1.2D+W+L+0.5S LRFD12: +1.2D-W+L+0.5S LRFD13: +1.2D+Eh+L+0.2S+0.2D LRFD14: +1.2D-Eh+L+0.2S+0.2D LRFD15: +0.9D+Eh-0.2D LRFD16: +0.9D-Eh-0.2D LRFD17: +0.9D+W LRFD18: +0.9D Combination 2 results: Envelop X Vmax Vmin Mmax Mmin φMn_Pos φMn_Neg φVn Check V Check M 8.95 2.190822 - 0.8351815 8.14 -0.42 23.85 27.93 18.89 Ok Ok 9 0.3815255 -1.649178 8.25 -0.46 23.85 27.93 18.89 Ok Ok 9 0.3815255 -1.649178 8.25 -0.46 23.85 27.93 18.89 Ok Ok 13.95 0.0648185 -0.839178 3.42 -2.28 23.85 27.93 18.89 Ok Ok H =24 h =22 bf =24 bw =16 tf =5 Yt = (h✕bw✕h/2+Max(0,(bf-bw)✕tf✕tf/2))/(h✕bw+Max(0,(bf-bw)✕tf))= 10.13 in Page 101 of 108 1011 W Second St 5/1/2025 Yb = h-Yt11.87 in I = bw✕h✕h✕h/12+h✕bw✕(h/2-Yt)✕(h/2-Yt)+Max(0,(bf-bw))✕tf✕tf✕tf/12+Max(0,(bf- bw))✕tf✕(tf/2-Yt)✕(tf/2-Yt)= 16875.77 in4 St = I/Yt= 1665.48 in3 Sb = I/Yb= 1422.03 in3 fr = 5√fc= 335.41 psi φMn_Pos=0.6✕(Min(St✕0.85✕f'c, Sb✕fr)/12000) φMn_Neg=0.6✕(Min(St✕fr,Sb✕0.85✕f'c)/12000) φVn=0.6 * (4/3*√fc*bw*h/1000) Page 102 of 108 1011 W Second St 5/1/2025 Sazan Project: 1011 Job Ref. B Fondansion: B Sheet no./rev R1 Calc. by N.K Date 2023/02/02 Chk'd by Date 2023/02/02 App'd by Date 2023/02/02 FOOTING ANALYSIS In accordance with ACI318-19 Overall design status PASS Overall design utilisation; 0.468 Description Unit Applied Resisting Utilization Result Soil bearing Ksf 701.29 1500 0.468 Pass Moment, positive kip_ft 10.11 17.78 0.569 Pass Moment, negative kip_ft 0 20.82 0 Pass Shear kip 4.385 17.78 0.247 Pass Pad footing details Length of footing L=18.16 ft Width of footing b=16 in Footing area A=2.02 ft2 Depth of footing H=24 in Density of concrete mass=145 lb/ft3 load case : W , Eh , D , L , Lr Point loads P (Kip) a (ft) loadCase -4.6 0.5 W -4.43 0.5 Eh 4.4 17.5 W 4.5 17.5 Eh 0.696 2.84 D 0.041 2.84 L 0.76 2.84 Lr -0.554 2.84 W 0.696 15.4 D 0.041 15.4 L 0.76 15.4 Lr Page 103 of 108 1011 W Second St 5/1/2025 -0.554 15.4 W 4.5 3.1 W 4.3 3.1 Eh -4.5 15 W -4.3 15 Eh W Eh Page 104 of 108 1011 W Second St 5/1/2025 D L Lr Distributed Loads W1 (Kip) W2 (Kip) a (ft) b (ft) loadCase 0.2186 0.2186 0 18.16 D 0.44 0.44 0 18.16 D 0.0133 0.0133 0 18.16 L 0.0266 0.0266 0 18.16 Lr Footing analysis for soil and stability Load combinations per ASCE 7-16 ASD01: +D ASD02: +D+L ASD03: +D+Lr ASD04: +D+S Page 105 of 108 1011 W Second St 5/1/2025 ASD05: +D+0.75L+0.75Lr ASD06: +D+0.75L+0.75S ASD07: +D+0.6W ASD08: +D+0.75L+0.45W+0.75Lr ASD09: +D+0.75L+0.45W+0.75S ASD10: +D+0.14D+0.7Eh ASD11: +D+0.11D+0.525Eh+0.75L+0.75S ASD12: +0.6D-0.14D+0.7Eh ASD13: +D+0.14D-0.7Eh ASD14: +D+0.11D-0.525Eh+0.75L+0.75S ASD15: +0.6D-0.14D-0.7Eh Load Combinations q max q min q allowed Check Bearing Stress L/6 e L' ASD01 584.35 461.86 1500 OK 3.03 0 0 ASD02 599.58 469.97 1500 OK 3.03 0 0 ASD03 701.29 447.62 1500 OK 3.03 0.01 0 ASD04 584.35 461.86 1500 OK 3.03 0 0 ASD05 683.48 457.27 1500 OK 3.03 0.01 0 ASD06 595.77 467.95 1500 OK 3.03 0 0 ASD07 725.02 283.81 1995 OK 3.03 1.1 0 ASD08 788.99 323.74 1995 OK 3.03 0.72 0 ASD09 701.28 334.41 1995 OK 3.03 0.8 0 ASD10 904.39 292.34 1995 OK 3.03 1.14 0 ASD11 838.72 343.11 1995 OK 3.03 0.86 0 ASD12 507.03 21.73 1995 OK 3.03 2.8 0 ASD13 760.7 427.92 1995 OK 3.03 -1.14 0 ASD14 694.39 481.38 1995 OK 3.03 -0.86 0 ASD15 446.64 30.57 1995 OK 3.03 -2.84 0 ASD03 FOOTING DESIGN In accordance with ACI318-19 Material details Page 106 of 108 1011 W Second St 5/1/2025 Compressive strength of concrete f'c = 2500 psi Concrete type Normal Analysis and design of concrete footing Load combinations per ASCE 7-16 LRFD01: +1.4D LRFD02: +1.2D+1.6L+0.5Lr LRFD03: +1.2D+1.6Lr+L LRFD04: +1.2D+1.6Lr+0.5W LRFD05: +1.2D+1.6Lr-0.5W LRFD06: +1.2D+1.6S+L LRFD07: +1.2D+1.6S+0.5W LRFD08: +1.2D+1.6S-0.5W LRFD09: +1.2D+W+L+0.5Lr LRFD10: +1.2D-W+L+0.5Lr LRFD11: +1.2D+W+L+0.5S LRFD12: +1.2D-W+L+0.5S LRFD13: +1.2D+Eh+L+0.2S+0.2D LRFD14: +1.2D-Eh+L+0.2S+0.2D LRFD15: +0.9D+Eh-0.2D LRFD16: +0.9D-Eh-0.2D LRFD17: +0.9D+W LRFD18: +0.9D Combination 2 results: Envelop X Vmax Vmin Mmax Mmin φMn_Pos φMn_Neg φVn Check V Check M 0.5 4.3848185 -4.439577 0.05 -0.06 17.78 20.82 14.08 Ok Ok 3.1 0.9515255 - 1.1466165 10.11 -10.54 17.78 20.82 14.08 Ok Ok 0.5 4.3848185 -4.439577 0.05 -0.06 17.78 20.82 14.08 Ok Ok 3.1 0.9515255 - 1.1466165 10.11 -10.54 17.78 20.82 14.08 Ok Ok Page 107 of 108 1011 W Second St 5/1/2025 H =24 h =22 bf =24 bw =16 tf =5 Yt = (h✕bw✕h/2+Max(0,(bf-bw)✕tf✕tf/2))/(h✕bw+Max(0,(bf-bw)✕tf))= 10.13 in Yb = h-Yt11.87 in I = bw✕h✕h✕h/12+h✕bw✕(h/2-Yt)✕(h/2-Yt)+Max(0,(bf-bw))✕tf✕tf✕tf/12+Max(0,(bf- bw))✕tf✕(tf/2-Yt)✕(tf/2-Yt)= 16875.77 in4 St = I/Yt= 1665.48 in3 Sb = I/Yb= 1422.03 in3 fr = 5√fc= 250 psi φMn_Pos=0.6✕(Min(St✕0.85✕f'c, Sb✕fr)/12000) φMn_Neg=0.6✕(Min(St✕fr,Sb✕0.85✕f'c)/12000) φVn=0.6 * (4/3*√fc*bw*h/1000) Page 108 of 108 1011 W Second St 5/1/2025