HomeMy WebLinkAbout2907 S Halladay St - 101119070, 20182651, 30147179 & 40139034 - Plan STATE OF CALIFORN IARENEW
11-30-25Lic.No.C-1 0457
JOHN G.CATAL DOREGISTERED ARCHITECT
GROUP S-1 / 2,086 S.F.
2,086 S.F. / 500 = 5 OCCUPANTS
SCOPE OF WORK
1. INTERIOR TENANT IMPROVEMENT TO CONVERT AN EXISTING STORAGE TO
A CANNABIS DISTRIBUTION FACILITY.
2. NEW SCREENING FOR EXISTING MECHANICAL ROOF EQUIPMENT.
HEIGHT: 30", LENGTH: 11'-0", WIDTH: 10'-0"
NOTE: ACCESSIBLE COMMUNITY RESTROOM AND ACCESSIBLE SITE WORK IS
EXISTING AND IS ONLY SHOWN FOR REFERENCE.
ALL SITE WORK HAS BEEN PREVIOUSLY APPROVED UNDER PERMITS # 101112158,
101112159 AND 101112160
ALL NEW WORK SHALL CONFORM TO ALL APPLICABLE BUILDING CODES TO THE LATEST RELEASE:
2022 CALIFORNIA BUILDING CODE (“CBC”)
2022 CALIFORNIA EXISTING BUILDING CODE (“CEBC”)
2022 CALIFORNIA MECHANICAL CODE (“CMC”)
2022 CALIFORNIA PLUMBING CODE (“CPC”)
2022 CALIFORNIA FIRE CODE (“CFC”)
2022 CALIFORNIA ELECTRICAL CODE (“CEC”)
2022 CALIFORNIA ENERGY CODE
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (“CALGREEN”)
2022 CALIFORNIA HEALTH AND SAFETY CODE (“CHSC”)
CALIFORNIA CODE OF REGULATIONS (“CCR”)
SANTA ANA MUNICIPAL CODE
2022
PHONE: (952)484-5948
BUILDING AREA OF UNIT
IN SCOPE OF WORK:2,086 S.F.
1
1
CERTIFICATION OF PATH OF TRAVEL COMPLIANCE
I, JOHN G. CATALDO, A LICENSED ARCHITECT IN RECORD, HEREBY CERTIFY THAT I
HAVE INSPECTED THE EXISTING PATH OF TRAVEL AND DETERMINED THAT IT FULLY
COMPLIES WITH THE PROVISIONS SET FORTH IN CHAPTER 11B OF THE 2022
CALIFORNIA BUILDING CODE (CBC).
ALL SITE WORK HAS BEEN PREVIOUSLY APPROVED UNDER PERMITS # 101112158,
101112159 AND 101112160
DATE: 06/10/24
1
Bldg# 101119070
Elec# 20182651
Plmg# 30147179
Mech# 40139034
APPROVALS:
PLNG - CSantana
BLDG - WLee
POLICE - BMartin
ELEC - MSmith
PLMG - TLuka
MECH - TLuka
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
C4
39
'
-
6
"
20
'
-
0
"
19
'
-
6
"
24'-3"24'-3"1'-6"
6
5
4
ABCD
EXIT
(E) DOOR LEVER
HARDWARE
4'
-
0
"
5'
-
0
"
D2
A-501
A4
AS-002
24"
1'-0"
5'-9"
55'-6"
10'-4"
18
'
-
1
1
"
(E) DOOR LEVER
HARDWARE
N
EXISTING
LOBBY
(NO WORK)
NEW
DISTRIBUTION ROOM
(NO WORK)
COMMUNAL
RESTROOM 2
A-101
PROCESSING
AREA
OUTBOUND AREA
INTAKE AREA
STATE OF CALI FORN I ARENEW
11-30-25Lic. No. C-1 0457
JOHN G. CATALDOREGISTERED ARCHITECT
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
48
"
M
I
N
.
T
O
L
O
W
E
S
T
T
A
C
T
I
L
E
60
"
M
A
X
.
T
O
H
I
G
H
E
S
T
T
A
C
T
I
L
E
TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48
INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND
SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST
BRAILLE CELLS AND 60 INCHES MAXIMUM ABOVE THE FINISH
FLOOR OR GROUND SURFACE, MEASURED FROM THE
BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS.
REFER TO FIGURE 11B-703.4.1.
REFER TO DETAIL D1 FOR SIGN
MOUNTING HEIGHT REQUIREMENTS
ALL GENDER DO
O
R
S
I
G
N
5
8
"
-
6
0
"
TO
C
E
N
T
E
R
L
I
N
E
O
F
S
Y
M
B
O
L
REFER TO DETAIL D1 FOR WALL SIGN
MOUNTING HEIGHT REQUIREMENTS
ALL-GENDER TOILET AND BATHING
FACILITIES SHALL BE IDENTIFIED BY A
CIRCLE, 1/4 INCH THICK AND 12 INCHES
IN DIAMETER WITH A 1/4 INCH THICK
TRIANGLE WITH A VERTEX POINTING
UPWARD SUPERIMPOSED ON THE CIRCLE
AND WITHIN THE 12-INCH DIAMETER.
THE COLOR OF THE TRIANGLE SYMBOL
SHALL CONTRAST WITH THE COLOR OF
THE CIRCLE SYMBOL, EITHER LIGHT ON A
DARK BACKGROUND OR DARK ON A
LIGHT BACKGROUND. THE CIRCLE
SYMBOL SHALL CONTRAST WITH THE
COLOR OF THE DOOR, EITHER LIGHT ON
A DARK BACKGROUND OR DARK ON
LIGHT BACKGROUND.
17"-18"
STATE OF CALI FORN I ARENEW
11-30-25Lic. No. C-1 0457
JOHN G. CATALDOREGISTERED ARCHITECT
1
1
1
1
1
1
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
N
1
2
3
4
5
6
G F E D C B A
B1
AS-002
A1
AS-002
C2
AS-002
D2
AS-002
(E) 80'-0"(E) 50'-5"
16
'
-
0
"
2'
-
0
"
3'
-
0
"
18
'
-
0
"
M
I
N
8'-6" MIN
S.
H
A
L
L
A
D
A
Y
S
T
R
E
E
T
140.00'
140.00'
10
0
.
0
0
'
10
0
.
0
0
'
1 2 3 4 5 6 7
8 9 11 1210
EXISTING
PART OF SCOPE
2905
NOT A PART
2903
2907
2909 COMMUNAL
RESTROOM
(E
)
3
5
'
-
0
"
2
A-101
A4
AS-002
NOT A PART
NO PARKING NOT A PART
EXISTING
EXISTING
PARAPET HEIGHT 2'-0"
10'-0"
2'-11"2'-11"
1'
-
6
"
3'
-
1
"
11
'
-
0
"
3'
-
0
"
3'
-
1
"
4'
-
1
1
"
03
AS-001 NEW SCREEN WALL
EXISTING MECHANICAL UNIT
EXISTING
EXISTING ACCESSIBLE PATH OF
TRAVEL FROM ACCESSIBLE PARKING
STALL TO TENANT
ENTRANCE.11B-502.7.1
INDICATED BY STRIPING
SLOPE >1:20
CROSS SLOPE > 2%
A4
AS-002
EXISTING
A4
AS-002
EXISTING
4'
-
0
"
4'-0"
4'
-
0
"
LINE OF SIGHTPROPERTY LINE
6'
-
0
"
300'-0"
EXISTING RTU
2'
-
0
"
4'-0"
30
"
SC
R
E
E
N
W
A
L
L
H
E
I
G
H
T
6"
6"
℄ HSS COL
3
-
EXISTING PLYWOOD
6"
MI
N
.
ROOF TOP
UNIT
2
1
4
1
1
/
2
"
2
6
5
1 GA 25 CORRUGATED GALVANIZED STEEL
MATCH BUILDING COLOR
FOR SIDING ATTACHMENT TO
HORIZONTAL/VERTICAL SUPPORTS USE #8
SELF-TAPPING SCREWS @ 12" O.C. ±
2 HSS 2" X 2" X 3/16" HORIZONTAL FRAME
TOP & BOTTOM W/ (1) 1/2"Ø M.B.
3 HSS 3" X 3" X 3/16" STEEL POST
@ 4'-0" O.C. MAX.
4 3/16" THK. STEEL PLATE ENDS
@ EACH POST
5
3/8" THK. STEEL PLATE X 9" WIDE X
9" LONG W/ (4) 1/2"Ø X 2-1/2" LONG LAG SCREWS
6 3/16" THK. GUSSET PLATE X 4" WIDE X
4" LONG W/ (1) 1/2"Ø M.B.
3
(E) 2X RAFTERS
ADD'L 4 X 8 BLOCKING
W/ SIMPSON "A35"
@ EA. END
WHERE REQUIRED
NOTE: METAL SCREEN TO NOT BE REFLECTIVE AND
TO MATCH EXISTING BUILDING
4"
GUSSET PLATE
SEE SCREEN SECTION
STEEL POST
SEE SCREEN SECTION
STEEL PLATE
SEE SCREEN SECTION(E) PLYWOOD SHEATHING
3/16"
9"
3 1/2"
4"
1
1
/
2
"
1
1
/
2
"
STEEL PLATE
SEE SCREEN SECTION
GUSSET PLATE
SEE SCREEN SECTION
STEEL POST
SEE SCREEN SECTION
A
-
A
-
ADD'L 4 X 8 BLOCKING
W/ SIMPSON "A35"
@ EA. END
WHERE REQUIRED
SCALE: 1/16" = 1'
300' LINE OF SIGHT DETAIL
210'0 20'5'
SCALE: 1" = 10'
SITE PLAN / ROOF PLAN
110'0 20'5'
STATE OF CALI FORN I ARENEW
11-30-25Lic. No. C-1 0457
JOHN G. CATALDOREGISTERED ARCHITECT
NOT TO SCALE
SCREEN WALL SECTION
3
NOT TO SCALE
STEEL POST AT ROOF
4
1
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
STATE OF CALI FORN I ARENEW
11-30-25Lic. No. C-1 0457
JOHN G. CATALDOREGISTERED ARCHITECT
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
32:(5
/,*+7,1*
%5$1&+&,5&8,7
(0(5*(1&</,*+7,1*
$%%5(9,$7,216 6<0%2//,67 *(1(5$/127(6
6,1*/(/,1(',$*5$0.(<127(6
*(1(5$/127(6
0
6,1*/(/,1(',$*5$0)255()(5(1&(21/<121(::25.
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
& % $
3$572)6&23(
127$3$57
&20081,$/
5(675220
127$3$57
123$5.,1*127$3$57
*(1(5$/127(6
.(<127(6
(/(&75,&$/32:(53/$1
29(5$//6,7(3/$1
VV
V
V
7&
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
M-1
MECHANICAL
NOTES
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
M-2
MECHANICAL
SCHEDULES AND
DETAILS
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
PART OF SCOPE
2907
EXIT
SCALE:MECHANICAL PLAN
01
1/4" = 1'-0"
M-3
MECHANICAL
PLAN
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
M-4
TITLE 24
CALCULATION
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
1
2
3
4
5
6
G F E D C B A
140.00'
140.00'
10
0
.
0
0
'
10
0
.
0
0
'
1 2 3 4 5 6 7
8 9 11 1210
PART OF SCOPE
2905
NOT A PART
2903
29072909COMMUNIAL
RESTROOM
NOT A PART
NOT A PART
P-1
PLUMBING PLAN
AND DETAILS
SCALE:PLUMBING SITE PLAN
01
1/8" = 1'-0"
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
Planning & Building Agency
Building and Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714)-647-5800
www.santa-ana.org
COMMERCIAL CANNABIS BUSINESS
SUBMITTAL CHECKLIST
PCC-18
REV: 09/02/2021 Page 1 of 1
THIS FORM SHALL BE COMPLETED BY A CALIFORNIA REGISTERED
ARCHITECT OR CIVIL ENGINEER.
Instructions: In order to submit for plan check for Commercial Cannabis Business (CCB)
projects, the architect or civil engineer shall complete all sections, check all boxes and sign the
certification section below. This checklist shall be completed prior to the time of plan submittal.
Unless all answers are checked Yes, plans will not be accepted.
Project Address:
Yes No
1. ☐ ☐ All CCB plans shall be stamped and signed by a California registered architect
or civil engineer.
2. ☐ ☐ Provide Architectural, Structural, Mechanical, Electrical, and Plumbing (MEP)
plans at time of submittal. Deferred submittal is not acceptable for MEP.
3. ☐ ☐ Provide 4 separate submittal packages: 1) Architectural and Structural
2) Mechanical 3) Electrical 4) Plumbing (MEP).
4. ☐ ☐ Provide 3 sets of Architectural and Structural plans and 2 sets of MEP plans.
5. ☐ ☐ Provide site plan, existing floor plan, proposed floor plan, egress plan. Provide
equipment plan and structural plan if applicable.
6. ☐ ☐ Note on plan a list of all hazardous materials and quantities. If there are no
hazardous materials, note on plan that there are no hazardous materials to be
stored on site.
7. ☐ ☐ Plans are required to be submitted separately to Orange County Fire Authority
(OCFA) for review prior to plan submittal.
Indicate Service Route number: SR #:___________
8. ☐ ☐ On the plan, describe in detail the manufacturing process from material delivery,
storage, handling, packaging, and shipping of finished products.
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name: Signature:
Architect/Engineer License Number: Date:
Phone Number: Email Address:
2907 S HALLADAY STREET
John G. Cataldo A.I.A. C.S.I. Architect, INC
C-10457
(626)799-4400
04/10/24
NATALYAL@JOHNCATALDO.COM
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
Planning & Building Agency
Building and Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714)-647-5800
www.santa-ana.org
COMMERCIAL CANNABIS BUSINESS
PLAN CHECK REQUIREMENTS
PCC-01
REV: 11/24/2020 Page 1 of 3
Thank you for your interest in operating a commercial cannabis business in Santa Ana. The information
below is intended to provide guidance on the requirements for commercial cannabis business plan check.
This Information is not intended to identify every code requirement; therefore, applicants must follow all
the requirements as stated in the California Code of Regulations (“CCR”), California Building Standards
Code (“CBSC”) and the California Health and Safety Code (“CHSC”) as adopted and/or modified by the City
and as referenced in the City of Santa Ana Municipal Code.
Plan Requirements
All plans for cannabis projects including but not limited to cultivators, distributors, manufacturers, testing
laboratories, and retailers shall be prepared, stamped and signed by a California licensed architect or
registered professional engineer.
Plan quality. Construction documents shall be of sufficient clarity to indicate the location, nature and
extent of the work proposed and show in detail that the project will conform to the provisions of the CCR,
CBSC, CHSC and/or relevant laws, ordinances, rules and regulations of the City and State. Specify the floor
area of the building or tenant space, previous and proposed occupancy group(s) and use(s), type of
construction, number of stories, building height, type of fire sprinklers system and/or fire alarm system
provided, fire separation distance or setback of building to property lines or other buildings on the lot,
and the types and number of parking space(s) provided for the site on the first sheet or title sheet of the
construction documents. Include justification and analysis for increase in area, height, and/or story where
applicable. Plans that do not meet this minimum level of information will be rejected.
Submittal requirements. All commercial cannabis project submittals must include architectural, structural
(if required), and Mechanical, Electrical, and Plumbing (MEP) at the time of submittal. Three (3) sets of
architectural plans and two (2) sets each of the MEPs are required. Please separate MEPs by discipline, as
each discipline will be routed to a separate plan checker.
Facility operations. Plans shall include a summary of the daily operations of the facility, and where these
operations will occur. This may include, but is not limited to: growing, harvesting, drying, curing, trimming,
washing/cleaning, extracting, post-processing, inspecting, testing, packaging, labeling, storing, retailing,
etc. If plant extraction will occur in the facility, plans should provide a summary of the intended extraction
process.
List of systems and equipment. A list of all mechanical systems, environmental systems, generation
systems, and fuel gas equipment proposed to be utilized on the property shall be provided. This includes
carbon dioxide generation systems, extraction equipment, etc. (CMC Section 302.1).
Relevant energy codes. The California Energy Code will apply to newly constructed buildings, building
additions and building alteration for project submitted to the City for plan review. The California Energy
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
REV: 11/24/2020 Page 2 of 3
Code may impact the design and installation, including but not limited to, the building envelope, space-
conditioning systems, water-heating systems, solar ready buildings, indoor lighting systems of buildings,
outdoor lighting systems and signs located either indoors or outdoors.
Relevant Green Building codes. The California Green Building Code will apply to all newly constructed
buildings, building addition and alteration per California Green Building Code 2019.
Permit Issuance
Relevant codes. The currently adopted building codes and standards that have been adopted by the City
are as follows:
2019 California Building Code (“CBC”)
2019 California Existing Building Code (“CEBC”)
2019 California Mechanical Code (“CMC”)
2019 California Plumbing Code (“CPC”)
2019 California Fire Code (“CFC”)
2019 California Electrical Code (“CEC”)
2019 California Energy Code
2019 California Green Building Standards Code (“CalGreen”)
2019 California Health and Safety Code (“CHSC”)
California Code of Regulations (“CCR”)
Santa Ana Municipal code
Prior to permit issuance, all cannabis projects must obtain the following clearances/approvals as
applicable:
1.Internal agencies/divisions:
a.Building Division
b.Planning Division
c.Police Department
d.Public Works Agency
2.External agencies:
a.Orange County Fire Authority (OCFA)
b.Orange County Sanitation District (OCSD)
Contractor qualifications. All construction and remodeling work must be performed by CA licensed Class
A or Class B contractors. All building trades work must be performed by a State of California licensed
contractor(s).
Accessibility to commercial buildings. All areas of newly designed and newly constructed buildings and
facilities and altered portions of existing buildings and facilities shall comply with the CBC Chapter 11B to
ensure that barrier-free design is incorporated and accessible-to and usable-by persons with disabilities.
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
REV: 11/24/2020 Page 3 of 3
Odor Control, Gas Detection, and Environmental Control Systems
Odor control. Every Cannabis Business shall implement adequate ventilation system and odor control
filtration measures to prevent odors from inside the cannabis facility from being detected outside the
cannabis facility, to include building and the unit. A licensed Mechanical engineer shall design the system
that is capable of preventing odors from inside the cannabis facility from being detected outside the
cannabis facility. The design of the ventilation and filtration system shall be based on industry -specific
best control technologies and best management practices to effectively mitigate cannabis odors. The
system shall use a range of odor mitigation practices to control odor-emitting activities, sources, and
locations (per the Mechanical handout).
Carbon dioxide enrichment gas detection. A gas detection system shall be provided in rooms and indoor
areas in which carbon dioxide enrichment processes are located.
Extraction gas detection. Please note on the drawings: “For extraction processes utilizing flammable gases
as solvents, a continuous gas detection system shall be provided.”
Note on the floor plan the square footage of each of the following areas:
1.Cultivation canopy
2.Distribution/secured storage
3.Manufacturing and processing
4.Testing laboratory (as licensed by the State of California)
5.Retail
Please note that these figures will be used for both occupancy and business license taxation purposes.
Environmental control systems. Environmental control systems shall be implemented to minimize and/or
prevent the likelihood or mold and mildew growth and shall include a range of environmental control
technologies and practices to control humidity levels, illumination, heating, cooling, air circulation, and
ventilation. The system shall be compatible with odor prevention and ventilation systems to prevent
cannabis odors from being detected outside the cultivation facility, while still allowing for the permittee
to successfully cultivate.
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
INFORMATION REQUIRED FOR
COMMERCIAL CANNABIS
BUSINESS
MEC_CCB-01 CMC
A. APPLICABLE BUILDING STANDARDS
B. PLAN CHECK REQUIRED
1.In addition to the requirements in the “Information Required for Mechanical Plan Check”
handout (MEC-01), the following requirements shall be included as part of a mechanical
plan submitted for a Commercial Cannabis Businesses (CCB).
a.CCBs shall be required to provide an engineered air treatment system that ensures off-
site odors shall not result from its operations. The system shall be designed to provide
sufficient odor-absorbing ventilation and exhaust systems so that any odor generated
inside the location is not detected outside of the building, on adjacent properties or
public rights-of-way, or within any other unit located within the same building as the
business if the use occupies only a portion of a building.
b.The exhaust system shall have a means of replacing the exhausted air with makeup air.
Either interlocked mechanically or negative pressure natural ventilation.
c.Calculations will be required on the plans to show that the exhaust system will be
creating a negative pressure in the business so as to draw in fresh ventilation air. A note
will be added to the plans stating that an air balance report will be required to show
compliance with the approved plans. The complete report, including a statement of
compliance on company letterhead from the entity designated by the design engineer
shall include a wet-stamp and wet signature.
d.The inlet of each exhaust will have a filter installed which provides compliance with
Section B.1.a. of this handout. The filters will have a replacement schedule of monthly.
Owner/Operator shall maintain written service records and provide them to the Authority
Having Jurisdiction (AHJ) upon request.
e.Each exhaust fan will be independently ducted out through the roof of the business.
f.Penetrations larger than 96 square inches will require Police department approval
before rough mechanical inspection can be approved.
g.New and existing roof top units shall have their filters upgraded to comply with Section
B.1.a of this handout and shall have a replacement schedule of monthly.
Owner/Operator shall maintain written service records and provide them to the AHJ
upon request.
2.This list of CCB requirements does not give permission for the installer/owner/operator, of
said CCB, to violate any of the provisions set forth in the California Building Codes.
California Building Code (CBC) California Electrical Code (CEC)
California Green Building Standards (CAL Green) California Mechanical Code (CMC)
California Plumbing Code (CPC) California Fire Code (CFC)
Santa Ana Municipal Code (SAMC) California Energy Code (Title 24, Part 6)
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
INFORMATION REQUIRED FOR
COMMERCIAL CANNABIS
BUSINESS
ELECTRICAL PLAN CHECK
ELC_CCB-01 CEC
A. APPLICABLE BUILDING STANDARDS
B. PLAN CHECK REQUIRED
1.In addition to the requirements in the “Information Required for Electrical Plan Check
Submittal” handout (ELC-01), the following requirements shall be included as part of an
electrical plan submitted for a Commercial Cannabis Businesses (CCB).
a.CCBs that perform extraction operations often use hazardous materials—volatile
materials or asphyxiants. If the project includes the use of hazardous materials, detailed
information is required. Without acceptable information, plan approval will not be given.
i.Classification of hazardous areas or locations is not the responsibility of the
authority having jurisdiction or the installing electrical contractor but of the design
professional.
ii.Classification requires the disclosure of materials involved, quantities, storage
location and methods, handling, etc.
iii.Hazardous area classification requires reference to other applicable standards
to determine the classification of an area and the extent of that area or location.
This process should include a team of professionals (experts in their fields) in
the risk analysis and assessment. NFPA 497 Recommended Practice for the
Classification of Flammable Liquids, Gases, or Vapors and of Hazardous
(Classified) Locations for Electrical Installations in Chemical Process Area is
among the other standards that must be used.
iv.All hazardous (classified) locations must be properly documented. The
documentation must be available to those who are authorized to design, install,
inspect, maintain, or operate the electrical equipment. 2019 California Electrical
Code (CEC) 500.4
b.For Hazardous locations, refer to CEC Articles 500, 501, and 502.
c.All equipment located within hazardous locations must be approved. This requires that
listing information and manufacturer’s installation instructions be provided.
d.Any measures to mitigate the hazard or processes that cannot be suddenly stopped
without increasing the hazard must be provided with a 2-hour emergency system as per
CEC Articles 700, 701.
e.Any generators and ATS equipment must be fully designed and detailed. Refer to CEC
Articles 445, 700, 701, 702, 705.
2.This list of CCB requirements does not give permission for the installer/owner/operator, of
said CCB, to violate any of the provisions set forth in the California Building Codes.
California Building Code (CBC) California Electrical Code (CEC)
California Green Building Standards (CAL Green) California Mechanical Code (CMC)
California Plumbing Code (CPC) California Fire Code (CFC)
Santa Ana Municipal Code (SAMC) California Energy Code (Title 24, Part 6)
Page 1 of 1 Rev: 04/29/21
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
STATE OF CALIFORN IARENEW
11-30-25Lic.No.C-1 0457
JOHN G.CATAL DOREGISTERED ARCHITECT
GROUP S-1 / 2,086 S.F.
2,086 S.F. / 500 = 5 OCCUPANTS
SCOPE OF WORK
1. INTERIOR TENANT IMPROVEMENT TO CONVERT AN EXISTING STORAGE TO
A CANNABIS DISTRIBUTION FACILITY.
2. NEW SCREENING FOR EXISTING MECHANICAL ROOF EQUIPMENT.
HEIGHT: 30", LENGTH: 11'-0", WIDTH: 10'-0"
NOTE: ACCESSIBLE COMMUNITY RESTROOM AND ACCESSIBLE SITE WORK IS
EXISTING AND IS ONLY SHOWN FOR REFERENCE.
ALL SITE WORK HAS BEEN PREVIOUSLY APPROVED UNDER PERMITS # 101112158,
101112159 AND 101112160
ALL NEW WORK SHALL CONFORM TO ALL APPLICABLE BUILDING CODES TO THE LATEST RELEASE:
2022 CALIFORNIA BUILDING CODE (“CBC”)
2022 CALIFORNIA EXISTING BUILDING CODE (“CEBC”)
2022 CALIFORNIA MECHANICAL CODE (“CMC”)
2022 CALIFORNIA PLUMBING CODE (“CPC”)
2022 CALIFORNIA FIRE CODE (“CFC”)
2022 CALIFORNIA ELECTRICAL CODE (“CEC”)
2022 CALIFORNIA ENERGY CODE
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (“CALGREEN”)
2022 CALIFORNIA HEALTH AND SAFETY CODE (“CHSC”)
CALIFORNIA CODE OF REGULATIONS (“CCR”)
SANTA ANA MUNICIPAL CODE
2022
PHONE: (952)484-5948
BUILDING AREA OF UNIT
IN SCOPE OF WORK:2,086 S.F.
1
1
CERTIFICATION OF PATH OF TRAVEL COMPLIANCE
I, JOHN G. CATALDO, A LICENSED ARCHITECT IN RECORD, HEREBY CERTIFY THAT I
HAVE INSPECTED THE EXISTING PATH OF TRAVEL AND DETERMINED THAT IT FULLY
COMPLIES WITH THE PROVISIONS SET FORTH IN CHAPTER 11B OF THE 2022
CALIFORNIA BUILDING CODE (CBC).
ALL SITE WORK HAS BEEN PREVIOUSLY APPROVED UNDER PERMITS # 101112158,
101112159 AND 101112160
DATE: 06/10/24
1
Bldg# 101119070
Elec# 20182651
Plmg# 30147179
Mech# 40139034
APPROVALS:
PLNG - CSantana
BLDG - WLee
POLICE - BMartin
ELEC - MSmith
PLMG - TLuka
MECH - TLuka
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
C4
39
'
-
6
"
20
'
-
0
"
19
'
-
6
"
24'-3"24'-3"1'-6"
6
5
4
ABCD
EXIT
(E) DOOR LEVER
HARDWARE
4'
-
0
"
5'
-
0
"
D2
A-501
A4
AS-002
24"
1'-0"
5'-9"
55'-6"
10'-4"
18
'
-
1
1
"
(E) DOOR LEVER
HARDWARE
N
EXISTING
LOBBY
(NO WORK)
NEW
DISTRIBUTION ROOM
(NO WORK)
COMMUNAL
RESTROOM 2
A-101
PROCESSING
AREA
OUTBOUND AREA
INTAKE AREA
STATE OF CALI FORN I ARENEW
11-30-25Lic. No. C-1 0457
JOHN G. CATALDOREGISTERED ARCHITECT
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
48
"
M
I
N
.
T
O
L
O
W
E
S
T
T
A
C
T
I
L
E
60
"
M
A
X
.
T
O
H
I
G
H
E
S
T
T
A
C
T
I
L
E
TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48
INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND
SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST
BRAILLE CELLS AND 60 INCHES MAXIMUM ABOVE THE FINISH
FLOOR OR GROUND SURFACE, MEASURED FROM THE
BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS.
REFER TO FIGURE 11B-703.4.1.
REFER TO DETAIL D1 FOR SIGN
MOUNTING HEIGHT REQUIREMENTS
ALL GENDER DO
O
R
S
I
G
N
5
8
"
-
6
0
"
TO
C
E
N
T
E
R
L
I
N
E
O
F
S
Y
M
B
O
L
REFER TO DETAIL D1 FOR WALL SIGN
MOUNTING HEIGHT REQUIREMENTS
ALL-GENDER TOILET AND BATHING
FACILITIES SHALL BE IDENTIFIED BY A
CIRCLE, 1/4 INCH THICK AND 12 INCHES
IN DIAMETER WITH A 1/4 INCH THICK
TRIANGLE WITH A VERTEX POINTING
UPWARD SUPERIMPOSED ON THE CIRCLE
AND WITHIN THE 12-INCH DIAMETER.
THE COLOR OF THE TRIANGLE SYMBOL
SHALL CONTRAST WITH THE COLOR OF
THE CIRCLE SYMBOL, EITHER LIGHT ON A
DARK BACKGROUND OR DARK ON A
LIGHT BACKGROUND. THE CIRCLE
SYMBOL SHALL CONTRAST WITH THE
COLOR OF THE DOOR, EITHER LIGHT ON
A DARK BACKGROUND OR DARK ON
LIGHT BACKGROUND.
17"-18"
STATE OF CALI FORN I ARENEW
11-30-25Lic. No. C-1 0457
JOHN G. CATALDOREGISTERED ARCHITECT
1
1
1
1
1
1
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
N
1
2
3
4
5
6
G F E D C B A
B1
AS-002
A1
AS-002
C2
AS-002
D2
AS-002
(E) 80'-0"(E) 50'-5"
16
'
-
0
"
2'
-
0
"
3'
-
0
"
18
'
-
0
"
M
I
N
8'-6" MIN
S.
H
A
L
L
A
D
A
Y
S
T
R
E
E
T
140.00'
140.00'
10
0
.
0
0
'
10
0
.
0
0
'
1 2 3 4 5 6 7
8 9 11 1210
EXISTING
PART OF SCOPE
2905
NOT A PART
2903
2907
2909 COMMUNAL
RESTROOM
(E
)
3
5
'
-
0
"
2
A-101
A4
AS-002
NOT A PART
NO PARKING NOT A PART
EXISTING
EXISTING
PARAPET HEIGHT 2'-0"
10'-0"
2'-11"2'-11"
1'
-
6
"
3'
-
1
"
11
'
-
0
"
3'
-
0
"
3'
-
1
"
4'
-
1
1
"
03
AS-001 NEW SCREEN WALL
EXISTING MECHANICAL UNIT
EXISTING
EXISTING ACCESSIBLE PATH OF
TRAVEL FROM ACCESSIBLE PARKING
STALL TO TENANT
ENTRANCE.11B-502.7.1
INDICATED BY STRIPING
SLOPE >1:20
CROSS SLOPE > 2%
A4
AS-002
EXISTING
A4
AS-002
EXISTING
4'
-
0
"
4'-0"
4'
-
0
"
LINE OF SIGHTPROPERTY LINE
6'
-
0
"
300'-0"
EXISTING RTU
2'
-
0
"
4'-0"
30
"
SC
R
E
E
N
W
A
L
L
H
E
I
G
H
T
6"
6"
℄ HSS COL
3
-
EXISTING PLYWOOD
6"
MI
N
.
ROOF TOP
UNIT
2
1
4
1
1
/
2
"
2
6
5
1 GA 25 CORRUGATED GALVANIZED STEEL
MATCH BUILDING COLOR
FOR SIDING ATTACHMENT TO
HORIZONTAL/VERTICAL SUPPORTS USE #8
SELF-TAPPING SCREWS @ 12" O.C. ±
2 HSS 2" X 2" X 3/16" HORIZONTAL FRAME
TOP & BOTTOM W/ (1) 1/2"Ø M.B.
3 HSS 3" X 3" X 3/16" STEEL POST
@ 4'-0" O.C. MAX.
4 3/16" THK. STEEL PLATE ENDS
@ EACH POST
5
3/8" THK. STEEL PLATE X 9" WIDE X
9" LONG W/ (4) 1/2"Ø X 2-1/2" LONG LAG SCREWS
6 3/16" THK. GUSSET PLATE X 4" WIDE X
4" LONG W/ (1) 1/2"Ø M.B.
3
(E) 2X RAFTERS
ADD'L 4 X 8 BLOCKING
W/ SIMPSON "A35"
@ EA. END
WHERE REQUIRED
NOTE: METAL SCREEN TO NOT BE REFLECTIVE AND
TO MATCH EXISTING BUILDING
4"
GUSSET PLATE
SEE SCREEN SECTION
STEEL POST
SEE SCREEN SECTION
STEEL PLATE
SEE SCREEN SECTION(E) PLYWOOD SHEATHING
3/16"
9"
3 1/2"
4"
1
1
/
2
"
1
1
/
2
"
STEEL PLATE
SEE SCREEN SECTION
GUSSET PLATE
SEE SCREEN SECTION
STEEL POST
SEE SCREEN SECTION
A
-
A
-
ADD'L 4 X 8 BLOCKING
W/ SIMPSON "A35"
@ EA. END
WHERE REQUIRED
SCALE: 1/16" = 1'
300' LINE OF SIGHT DETAIL
210'0 20'5'
SCALE: 1" = 10'
SITE PLAN / ROOF PLAN
110'0 20'5'
STATE OF CALI FORN I ARENEW
11-30-25Lic. No. C-1 0457
JOHN G. CATALDOREGISTERED ARCHITECT
NOT TO SCALE
SCREEN WALL SECTION
3
NOT TO SCALE
STEEL POST AT ROOF
4
1
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
STATE OF CALI FORN I ARENEW
11-30-25Lic. No. C-1 0457
JOHN G. CATALDOREGISTERED ARCHITECT
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
32:(5
/,*+7,1*
%5$1&+&,5&8,7
(0(5*(1&</,*+7,1*
$%%5(9,$7,216 6<0%2//,67 *(1(5$/127(6
6,1*/(/,1(',$*5$0.(<127(6
*(1(5$/127(6
0
6,1*/(/,1(',$*5$0)255()(5(1&(21/<121(::25.
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
& % $
3$572)6&23(
127$3$57
&20081,$/
5(675220
127$3$57
123$5.,1*127$3$57
*(1(5$/127(6
.(<127(6
(/(&75,&$/32:(53/$1
29(5$//6,7(3/$1
VV
V
V
7&
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
M-1
MECHANICAL
NOTES
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
M-2
MECHANICAL
SCHEDULES AND
DETAILS
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
PART OF SCOPE
2907
EXIT
SCALE:MECHANICAL PLAN
01
1/4" = 1'-0"
M-3
MECHANICAL
PLAN
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
M-4
TITLE 24
CALCULATION
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
1
2
3
4
5
6
G F E D C B A
140.00'
140.00'
10
0
.
0
0
'
10
0
.
0
0
'
1 2 3 4 5 6 7
8 9 11 1210
PART OF SCOPE
2905
NOT A PART
2903
29072909COMMUNIAL
RESTROOM
NOT A PART
NOT A PART
P-1
PLUMBING PLAN
AND DETAILS
SCALE:PLUMBING SITE PLAN
01
1/8" = 1'-0"
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
Planning & Building Agency
Building and Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714)-647-5800
www.santa-ana.org
COMMERCIAL CANNABIS BUSINESS
SUBMITTAL CHECKLIST
PCC-18
REV: 09/02/2021 Page 1 of 1
THIS FORM SHALL BE COMPLETED BY A CALIFORNIA REGISTERED
ARCHITECT OR CIVIL ENGINEER.
Instructions: In order to submit for plan check for Commercial Cannabis Business (CCB)
projects, the architect or civil engineer shall complete all sections, check all boxes and sign the
certification section below. This checklist shall be completed prior to the time of plan submittal.
Unless all answers are checked Yes, plans will not be accepted.
Project Address:
Yes No
1. ☐ ☐ All CCB plans shall be stamped and signed by a California registered architect
or civil engineer.
2. ☐ ☐ Provide Architectural, Structural, Mechanical, Electrical, and Plumbing (MEP)
plans at time of submittal. Deferred submittal is not acceptable for MEP.
3. ☐ ☐ Provide 4 separate submittal packages: 1) Architectural and Structural
2) Mechanical 3) Electrical 4) Plumbing (MEP).
4. ☐ ☐ Provide 3 sets of Architectural and Structural plans and 2 sets of MEP plans.
5. ☐ ☐ Provide site plan, existing floor plan, proposed floor plan, egress plan. Provide
equipment plan and structural plan if applicable.
6. ☐ ☐ Note on plan a list of all hazardous materials and quantities. If there are no
hazardous materials, note on plan that there are no hazardous materials to be
stored on site.
7. ☐ ☐ Plans are required to be submitted separately to Orange County Fire Authority
(OCFA) for review prior to plan submittal.
Indicate Service Route number: SR #:___________
8. ☐ ☐ On the plan, describe in detail the manufacturing process from material delivery,
storage, handling, packaging, and shipping of finished products.
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name: Signature:
Architect/Engineer License Number: Date:
Phone Number: Email Address:
2907 S HALLADAY STREET
John G. Cataldo A.I.A. C.S.I. Architect, INC
C-10457
(626)799-4400
04/10/24
NATALYAL@JOHNCATALDO.COM
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
Planning & Building Agency
Building and Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714)-647-5800
www.santa-ana.org
COMMERCIAL CANNABIS BUSINESS
PLAN CHECK REQUIREMENTS
PCC-01
REV: 11/24/2020 Page 1 of 3
Thank you for your interest in operating a commercial cannabis business in Santa Ana. The information
below is intended to provide guidance on the requirements for commercial cannabis business plan check.
This Information is not intended to identify every code requirement; therefore, applicants must follow all
the requirements as stated in the California Code of Regulations (“CCR”), California Building Standards
Code (“CBSC”) and the California Health and Safety Code (“CHSC”) as adopted and/or modified by the City
and as referenced in the City of Santa Ana Municipal Code.
Plan Requirements
All plans for cannabis projects including but not limited to cultivators, distributors, manufacturers, testing
laboratories, and retailers shall be prepared, stamped and signed by a California licensed architect or
registered professional engineer.
Plan quality. Construction documents shall be of sufficient clarity to indicate the location, nature and
extent of the work proposed and show in detail that the project will conform to the provisions of the CCR,
CBSC, CHSC and/or relevant laws, ordinances, rules and regulations of the City and State. Specify the floor
area of the building or tenant space, previous and proposed occupancy group(s) and use(s), type of
construction, number of stories, building height, type of fire sprinklers system and/or fire alarm system
provided, fire separation distance or setback of building to property lines or other buildings on the lot,
and the types and number of parking space(s) provided for the site on the first sheet or title sheet of the
construction documents. Include justification and analysis for increase in area, height, and/or story where
applicable. Plans that do not meet this minimum level of information will be rejected.
Submittal requirements. All commercial cannabis project submittals must include architectural, structural
(if required), and Mechanical, Electrical, and Plumbing (MEP) at the time of submittal. Three (3) sets of
architectural plans and two (2) sets each of the MEPs are required. Please separate MEPs by discipline, as
each discipline will be routed to a separate plan checker.
Facility operations. Plans shall include a summary of the daily operations of the facility, and where these
operations will occur. This may include, but is not limited to: growing, harvesting, drying, curing, trimming,
washing/cleaning, extracting, post-processing, inspecting, testing, packaging, labeling, storing, retailing,
etc. If plant extraction will occur in the facility, plans should provide a summary of the intended extraction
process.
List of systems and equipment. A list of all mechanical systems, environmental systems, generation
systems, and fuel gas equipment proposed to be utilized on the property shall be provided. This includes
carbon dioxide generation systems, extraction equipment, etc. (CMC Section 302.1).
Relevant energy codes. The California Energy Code will apply to newly constructed buildings, building
additions and building alteration for project submitted to the City for plan review. The California Energy
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
REV: 11/24/2020 Page 2 of 3
Code may impact the design and installation, including but not limited to, the building envelope, space-
conditioning systems, water-heating systems, solar ready buildings, indoor lighting systems of buildings,
outdoor lighting systems and signs located either indoors or outdoors.
Relevant Green Building codes. The California Green Building Code will apply to all newly constructed
buildings, building addition and alteration per California Green Building Code 2019.
Permit Issuance
Relevant codes. The currently adopted building codes and standards that have been adopted by the City
are as follows:
2019 California Building Code (“CBC”)
2019 California Existing Building Code (“CEBC”)
2019 California Mechanical Code (“CMC”)
2019 California Plumbing Code (“CPC”)
2019 California Fire Code (“CFC”)
2019 California Electrical Code (“CEC”)
2019 California Energy Code
2019 California Green Building Standards Code (“CalGreen”)
2019 California Health and Safety Code (“CHSC”)
California Code of Regulations (“CCR”)
Santa Ana Municipal code
Prior to permit issuance, all cannabis projects must obtain the following clearances/approvals as
applicable:
1.Internal agencies/divisions:
a.Building Division
b.Planning Division
c.Police Department
d.Public Works Agency
2.External agencies:
a.Orange County Fire Authority (OCFA)
b.Orange County Sanitation District (OCSD)
Contractor qualifications. All construction and remodeling work must be performed by CA licensed Class
A or Class B contractors. All building trades work must be performed by a State of California licensed
contractor(s).
Accessibility to commercial buildings. All areas of newly designed and newly constructed buildings and
facilities and altered portions of existing buildings and facilities shall comply with the CBC Chapter 11B to
ensure that barrier-free design is incorporated and accessible-to and usable-by persons with disabilities.
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
REV: 11/24/2020 Page 3 of 3
Odor Control, Gas Detection, and Environmental Control Systems
Odor control. Every Cannabis Business shall implement adequate ventilation system and odor control
filtration measures to prevent odors from inside the cannabis facility from being detected outside the
cannabis facility, to include building and the unit. A licensed Mechanical engineer shall design the system
that is capable of preventing odors from inside the cannabis facility from being detected outside the
cannabis facility. The design of the ventilation and filtration system shall be based on industry -specific
best control technologies and best management practices to effectively mitigate cannabis odors. The
system shall use a range of odor mitigation practices to control odor-emitting activities, sources, and
locations (per the Mechanical handout).
Carbon dioxide enrichment gas detection. A gas detection system shall be provided in rooms and indoor
areas in which carbon dioxide enrichment processes are located.
Extraction gas detection. Please note on the drawings: “For extraction processes utilizing flammable gases
as solvents, a continuous gas detection system shall be provided.”
Note on the floor plan the square footage of each of the following areas:
1.Cultivation canopy
2.Distribution/secured storage
3.Manufacturing and processing
4.Testing laboratory (as licensed by the State of California)
5.Retail
Please note that these figures will be used for both occupancy and business license taxation purposes.
Environmental control systems. Environmental control systems shall be implemented to minimize and/or
prevent the likelihood or mold and mildew growth and shall include a range of environmental control
technologies and practices to control humidity levels, illumination, heating, cooling, air circulation, and
ventilation. The system shall be compatible with odor prevention and ventilation systems to prevent
cannabis odors from being detected outside the cultivation facility, while still allowing for the permittee
to successfully cultivate.
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
INFORMATION REQUIRED FOR
COMMERCIAL CANNABIS
BUSINESS
MEC_CCB-01 CMC
A. APPLICABLE BUILDING STANDARDS
B. PLAN CHECK REQUIRED
1.In addition to the requirements in the “Information Required for Mechanical Plan Check”
handout (MEC-01), the following requirements shall be included as part of a mechanical
plan submitted for a Commercial Cannabis Businesses (CCB).
a.CCBs shall be required to provide an engineered air treatment system that ensures off-
site odors shall not result from its operations. The system shall be designed to provide
sufficient odor-absorbing ventilation and exhaust systems so that any odor generated
inside the location is not detected outside of the building, on adjacent properties or
public rights-of-way, or within any other unit located within the same building as the
business if the use occupies only a portion of a building.
b.The exhaust system shall have a means of replacing the exhausted air with makeup air.
Either interlocked mechanically or negative pressure natural ventilation.
c.Calculations will be required on the plans to show that the exhaust system will be
creating a negative pressure in the business so as to draw in fresh ventilation air. A note
will be added to the plans stating that an air balance report will be required to show
compliance with the approved plans. The complete report, including a statement of
compliance on company letterhead from the entity designated by the design engineer
shall include a wet-stamp and wet signature.
d.The inlet of each exhaust will have a filter installed which provides compliance with
Section B.1.a. of this handout. The filters will have a replacement schedule of monthly.
Owner/Operator shall maintain written service records and provide them to the Authority
Having Jurisdiction (AHJ) upon request.
e.Each exhaust fan will be independently ducted out through the roof of the business.
f.Penetrations larger than 96 square inches will require Police department approval
before rough mechanical inspection can be approved.
g.New and existing roof top units shall have their filters upgraded to comply with Section
B.1.a of this handout and shall have a replacement schedule of monthly.
Owner/Operator shall maintain written service records and provide them to the AHJ
upon request.
2.This list of CCB requirements does not give permission for the installer/owner/operator, of
said CCB, to violate any of the provisions set forth in the California Building Codes.
California Building Code (CBC) California Electrical Code (CEC)
California Green Building Standards (CAL Green) California Mechanical Code (CMC)
California Plumbing Code (CPC) California Fire Code (CFC)
Santa Ana Municipal Code (SAMC) California Energy Code (Title 24, Part 6)
2907 S Halladay St - 101119070,
20182651, 30147179 & 40139034
7/22/2024
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
INFORMATION REQUIRED FOR
COMMERCIAL CANNABIS
BUSINESS
ELECTRICAL PLAN CHECK
ELC_CCB-01 CEC
A. APPLICABLE BUILDING STANDARDS
B. PLAN CHECK REQUIRED
1.In addition to the requirements in the “Information Required for Electrical Plan Check
Submittal” handout (ELC-01), the following requirements shall be included as part of an
electrical plan submitted for a Commercial Cannabis Businesses (CCB).
a.CCBs that perform extraction operations often use hazardous materials—volatile
materials or asphyxiants. If the project includes the use of hazardous materials, detailed
information is required. Without acceptable information, plan approval will not be given.
i.Classification of hazardous areas or locations is not the responsibility of the
authority having jurisdiction or the installing electrical contractor but of the design
professional.
ii.Classification requires the disclosure of materials involved, quantities, storage
location and methods, handling, etc.
iii.Hazardous area classification requires reference to other applicable standards
to determine the classification of an area and the extent of that area or location.
This process should include a team of professionals (experts in their fields) in
the risk analysis and assessment. NFPA 497 Recommended Practice for the
Classification of Flammable Liquids, Gases, or Vapors and of Hazardous
(Classified) Locations for Electrical Installations in Chemical Process Area is
among the other standards that must be used.
iv.All hazardous (classified) locations must be properly documented. The
documentation must be available to those who are authorized to design, install,
inspect, maintain, or operate the electrical equipment. 2019 California Electrical
Code (CEC) 500.4
b.For Hazardous locations, refer to CEC Articles 500, 501, and 502.
c.All equipment located within hazardous locations must be approved. This requires that
listing information and manufacturer’s installation instructions be provided.
d.Any measures to mitigate the hazard or processes that cannot be suddenly stopped
without increasing the hazard must be provided with a 2-hour emergency system as per
CEC Articles 700, 701.
e.Any generators and ATS equipment must be fully designed and detailed. Refer to CEC
Articles 445, 700, 701, 702, 705.
2.This list of CCB requirements does not give permission for the installer/owner/operator, of
said CCB, to violate any of the provisions set forth in the California Building Codes.
California Building Code (CBC) California Electrical Code (CEC)
California Green Building Standards (CAL Green) California Mechanical Code (CMC)
California Plumbing Code (CPC) California Fire Code (CFC)
Santa Ana Municipal Code (SAMC) California Energy Code (Title 24, Part 6)
Page 1 of 1 Rev: 04/29/21