HomeMy WebLinkAboutHOLD- 420 W 17th St - Plan2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 BI G S A V E R F O O D S T1.0 TITLE SHEET INDEX 430 W 17TH ST SANTA ANA, CA 92706-3609 VICINITY MAP BUILDING DEPARTMENT GOVERNMENT AGENCIES ARCHITECTURAL SHEET INDEX CONSULTANTS HEALTH DEPARTMENT GENERAL NOTES A B B R E V I A T I O N S 7 L E G E N D SCOPE OF WORK PROJECT DATA PROJECT ADDRESS AND LEGAL DESCRIPTION [E] BUILDING DATA DEFERRED PERMITS DESIGNER ARCHITECT: TENANT MEP NOTE: · NO CHANGE TO THE AREA OR SQ. FT OF THE BUILDING. BUILDING AREA: 23,262 S.F. NOTE: CITY OF SANTA ANA REQUIRED OWNER TO PROVIDE A LETTER ENSURING THAT SPRINKLERS ARE BEING PROVIDED THROUGH-OUT, PRIOR TO FINAL. LOT NUMBER: 23 TRACT NO: 113 BRIEF DESCRIPTION: BARTON TR LOT 23 TO 29 INC AND ALL -EX ST- LOT 30 AND LOTS 33 TO 3 9 INC AN D ALL -EX ST- LOT 40 AND ALL -N OF 16TH ST- LOT C LEGAL DESCRIPTION [E] PARKING STANDARD 145 SPACES ACCESSIBLE 5 ADA TOTAL [E] PARKING SPACES 150 TOTAL P.S. 1- STORY - 1 MEZZANINE COMMERCIAL BUILDING TYPE OF CONSTRUCTION: III-B & V-B ADJACENT OCCUPANCY: M (MARKET) PARCEL NUMBER: 005-110-02 2 ALL GENDER ACCESSIBLE RESTROOM PROVIDED 2022 CPC - CHAPTER 4 TABLE 422.1 MINIMUM PLUMBING FACILITIES BASED ON M OCCUPANCY ONLY GROCERY STORE WITHIN 1/3 OF A MILE 420 W. 17TH STREET SANTA ANA, CA 92706 FIRE DEPARTMENT MECHANICAL ELECTRICAL PLUMBING REFRIGERATION · · · STRUCTURAL TOILET FACILITY CALCULATION Bldg #104119343 Elect #20482841 Plumb #30447261 Mech #40339109 APPROVALS: PLNG - C. Santana BLDG - A. So POLICE - B. Martin PUBLIC WORKS - B. Sarlak ELECT - M. Smith PLUMB/MECH - T. Luka HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 234 1 LECHERIA CERVEZA A B C D E F DELI JUICE 2 3 41 CARNICERIA MARISCOS ABCDEF [E] EAST ELEVATION A0.2 AS BUILT ELEVATIONS 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 BI G S A V E R F O O D S 1NORTH ELEVATION - ENTRANCE / CHECKSTANDS / TORTILLERIA 3SOUTH ELEVATION - MEAT & SEAFOOD / DAIRY 4EAST ELEVATION - TORTILLERIA / PIZZA / BAKERY 2WEST ELEVATION - DAIRY / PRODUCE / WINE & BEER 1NORTH ELEVATION - ENTRANCE / CHECKSTANDS / TORTILLERIA 4EAST ELEVATION - TORTILLERIA / PIZZA / BAKERY 2WEST ELEVATION - DAIRY / PRODUCE / WINE & BEER 3SOUTH ELEVATION - MEAT & SEAFOOD / DAIRY HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 A D E F 2 3 41 A D E F BB CC 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 BI G S A V E R F O O D S NO R T H TR U E 2 A0.4 LEGEND A S B U I L T R O O F P L A N AS BUILT ROOF PLAN 1 ROOF SCREENING DET. HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 [A] THRESHOLDS [B] FLOOR FINISH SWITCH [C] DOOR BOTTOM RAIL CL CL So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 A D E F 2 3 41 A D E F BB CC SoloChill Micro Distributed Models: DA091, DA130, DA220 (N) CHECKSTAND (N) DAIRY COOLER (N) CREMERIA ISLAND PRODUCE JUICE BAR CONCOURSE (N) PAN DULCE (N) BAKERY (N) MEAT SERVICE SALES (E) FREEZER (N) HALL/ BACKSTOCK (E) HALL/ BACKSTOCK (N) MEAT COOLER (N) MEAT PREP 1 2 3 4 (N) BAKERY & KITCHEN FREEZER (M) TORTILLERIA PREP (N) BAKERY & KITCHEN COOLER (N) HALL/ BACKSTOCK (N) LA COCINA (N) BAKERY PREP A B C D E F (N)BREAK ROOM (N) CUSTOMER SERVICE (N) CHECK CASHING (N)SAFE ROOM (N) WOMEN RESTROOM (N) ALCOVE (M) TORTILLERIA SERVICE1 2 3 4 (M) BEER COOLER (M) PRODUCE COOLER (N) MEN RESTROOM B C D E F A (E) HALL/ BACKSTOCK EXIT CALCULATION · · · · PRODUCE PREP 3 A [E] MEZZANINE NO CHANGES 3 A A1.2 [N] EXIT PLAN 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 BI G S A V E R F O O D S 1 2 EXIT ROUTE & EXIT TACTILE SIGNS PER 2022 CBC - 1013.42022 CBC - 11B-303 F I R E D E P A R T M E N T N O T E S NO R T H TR U E [E] M E Z Z A N I N E 3 LEGEND [N] F L O O R P L A N HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 A B C (N) WOMEN RESTROOM WALL # 1 WALL # 2 HIGHCLIFK-4368 FVC_TOILETSITREOUS CHINA A B C B1 D WALL # 3 ℄℄ A B B1C WALL # 4 WALL # 4WALL # 1 WALL # 2 HIGHCLIFK-4368 FVC_TOILETSITREOUS CHINA WALL # 3 ℄℄ AB1C (N) MEN RESTROOM A B C B1 K (N) MEN RESTROOM K DB H J L H L L A2.1 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 BI G S A V E R F O O D S RESTROOMS ELEVATIONS3A.D.A. M A N E U V E R I N G C L E A R A N C E ENVIRONMENTAL HEALTH NOTES 1 2E L E V A T I O N S A T M E N R E S T R O O M E L E V A T I O N S A T W O M E N R E S T R O O M L A V A T O R I E S E L E V A T I O N S 4 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 MT W3 C2 C1 W6 D B5 X ZB5 34 12 JJW2EW2W5C Y MT O D W2 Z JW7W4 A B C D E F M W7 G G D W4 G S W1BBP S 2 3 41 W3 W2 W1 B D F G PRPQ ABCDEF W2 W8 B5 W1 W8 B5 I V B4 K L1 P T W8 W3 C5W4JJ JZ W2 W2 W2 Y O W2 D W MT W2 W3 O O A6.0 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 BI G S A V E R F O O D S INTERIOR ELEVATIONS 1NORTH ELEVATION - ENTRANCE / CHECKSTANDS / TORTILLERIA 3SOUTH ELEVATION - MEAT & SEAFOOD / DAIRY 4EAST ELEVATION - TORTILLERIA / PIZZA / BAKERY 2WEST ELEVATION - DAIRY / PRODUCE / WINE & BEER HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 ---- 2 3 41 A D E F 2 3 41 A D E F BB CC 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 BI G S A V E R F O O D S NO R T H TR U E 1 D1.0 D E M O L I T I O N P L A N DEMO PLAN LEGEND KEY NOTES HOLD- 420 W 17th St3/7/2025 2 3 41 A D E F 2 3 41 A D E F BB CC 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 BI G S A V E R F O O D S NO R T H TR U E 1 D1.1 D E M O L I T I O N R O O F P L A N DEMO ROOF PLAN LEGEND KEY NOTES HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 HOLD- 420 W 17th St3/7/2025 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 BI G S A V E R F O O D S F I R E D E P A R T M E N T N O T E S §§ §§ §§ §§ § § DETECTABLE WARNING DETAIL NOTES §§§ §§§ § [N] DETECTABLE WARNING 2 [N] TRUNCATED DOMES AT ZERO CURB FACE 31[N] DETECTABLE WARNING SD 1.1 SD 1.1 HOLD- 420 W 17th St3/7/2025 17TH STREET 16TH STREET DU R A N T S T R E E T RO S S S T R E E T NO P A R K I N G NO P A R K I N G 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 BI G S A V E R F O O D S NO R T H TR U E L E G E N D SD 1.0 SITE PLAN [E] HANDICAP LOGO 2 [E] HANDICAP SIGN 5 [E] HANDICAP SIGN §§ 3 [E] WHEEL STOP 6 NOTE: ·NO CHANGE TO THE AREA OR SQ. FT OF THE BUILDING. TYPE OF CONSTRUCTION: V-B TOTAL BUILDING AREA: 23,262 SQ.FT. OCCUPANCY: M (MARKET) PROJECT ADDRESS AND LEGAL DESCRIPTION BUILDING DATA 1- STORY COMMERCIAL BUILDING - BUILDING TO BE FULLY SPRINKLERED 420 W, 17TH STREET SANTA ANA, CA 92706 § § ACCESSIBLE PARKING SPACES DETAIL NOTES § 7 ACCESIBLE PARKING TYP 41SITE PLAN PARCEL NUMBER: 005-110-02 HOLD- 420 W 17th St3/7/2025 MEZZANINE FRAMING PLANA 1DETAIL 2DETAIL 3DETAIL 4DETAIL EN EN 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 08-25-24 ST R U C T U R A L E N G I N E E R GE O R G E K I L E D J I A N P: 8 1 8 . 6 3 5 . 1 6 9 1 gk s t r @ y a h o o . c o m HOLD- 420 W 17th St3/7/2025 FOUNDATION PLANA 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 08-25-24 ST R U C T U R A L E N G I N E E R GE O R G E K I L E D J I A N P: 8 1 8 . 6 3 5 . 1 6 9 1 gk s t r @ y a h o o . c o m HOLD- 420 W 17th St3/7/2025 ROOF FRAMING PLANA 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 08-25-24 ST R U C T U R A L E N G I N E E R GE O R G E K I L E D J I A N P: 8 1 8 . 6 3 5 . 1 6 9 1 gk s t r @ y a h o o . c o m HOLD- 420 W 17th St3/7/2025 3DETAIL 4DETAIL 5DETAIL 6DETAIL 7DETAIL 9DETAIL 11DETAIL 12DETAIL A B C D A B CAB A TOP PLATE OF HSS 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 08-25-24 ST R U C T U R A L E N G I N E E R GE O R G E K I L E D J I A N P: 8 1 8 . 6 3 5 . 1 6 9 1 gk s t r @ y a h o o . c o m HOLD- 420 W 17th St3/7/2025 1 TYPICAL HOOD SUPPORT 2CONDENSING UNIT SUPPORT 3RTU SUPPORT MAU SUPPORT7TYPICAL FAN SUPPORT 8 9DETAIL 10DETAIL 12DETAIL PLAN VIEW A B A B A B A B A B C A B 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 08-25-24 ST R U C T U R A L E N G I N E E R GE O R G E K I L E D J I A N P: 8 1 8 . 6 3 5 . 1 6 9 1 gk s t r @ y a h o o . c o m HOLD- 420 W 17th St3/7/2025 DETAIL 3DETAIL9 A CEILING PLAN VIEWACEILING PLAN VIEW 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 08-25-24 ST R U C T U R A L E N G I N E E R GE O R G E K I L E D J I A N P: 8 1 8 . 6 3 5 . 1 6 9 1 gk s t r @ y a h o o . c o m HOLD- 420 W 17th St3/7/2025 1DETAIL 2DETAIL 3DETAIL 4DETAIL 5DETAIL 6DETAIL 7DETAIL 8DETAIL 9DETAIL 10DETAIL 11DETAIL 12DETAIL 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 08-25-24 ST R U C T U R A L E N G I N E E R GE O R G E K I L E D J I A N P: 8 1 8 . 6 3 5 . 1 6 9 1 gk s t r @ y a h o o . c o m HOLD- 420 W 17th St3/7/2025 1 SECTION AT TORTILLERIA PREP A CEILING JOIST AT CONC WALLBFOOTING AT STEEL COLUMNCHSS BEAM TO COL CONN D HSS BEAM TO ROOF CONN 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 08-25-24 ST R U C T U R A L E N G I N E E R GE O R G E K I L E D J I A N P: 8 1 8 . 6 3 5 . 1 6 9 1 gk s t r @ y a h o o . c o m HOLD- 420 W 17th St3/7/2025 1 SECTION AT BAKERY PREP AND CREMERIA ISLAND2SECTION AT LA COCINA A PARTIAL SECTION AT L-SHAPED FRAME 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 08-25-24 ST R U C T U R A L E N G I N E E R GE O R G E K I L E D J I A N P: 8 1 8 . 6 3 5 . 1 6 9 1 gk s t r @ y a h o o . c o m HOLD- 420 W 17th St3/7/2025 1 SECTION AT MEAT PREP 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 08-25-24 ST R U C T U R A L E N G I N E E R GE O R G E K I L E D J I A N P: 8 1 8 . 6 3 5 . 1 6 9 1 gk s t r @ y a h o o . c o m HOLD- 420 W 17th St3/7/2025 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 01-11-2024 818-842-7285 01-11-2024 818-842-7285 MEL ANTHONY FAJARDO 1106 W. MAGNOLIA BLVD. SUITE A BURBANK, CA 91506 1106 W. MAGNOLIA BLVD. SUITE A BURBANK, CA 91506 E21979 PACIFIC ENGINEERING GROUP 420 W. 17TH STREET, SANTA ANA, CA 92706 HOLD- 420 W 17th St3/7/2025 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 01-11-2024 818-842-7285 01-11-2024 818-842-7285 MEL ANTHONY FAJARDO 1106 W. MAGNOLIA BLVD. SUITE A BURBANK, CA 91506 1106 W. MAGNOLIA BLVD. SUITE A BURBANK, CA 91506 E21979 PACIFIC ENGINEERING GROUP 420 W. 17TH STREET, SANTA ANA, CA 92706 HOLD- 420 W 17th St3/7/2025 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 CL CL So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 CL CL So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 EXIT STATISTICS Descrition Sbol Av Ma Min Ma/Min Av/Min CORRIDOR MEAT PREP STORAGE MEAT SERVICE BAKERY LUMINAIRE SCHEDULE Sbol Label Qt Luens LLF WattsCatalo Nuber Descrition TORTILLERIA SERVICE (E)30 0.70 75AbsoluteEXISTING FIXTURE 8 INDUSTRIAL LED LIGHT FIXTURE 13.6 fc 27.0 fc 2.3 fc 11.7:1 5.9:1 9.6 fc 22.7 fc 1.2 fc 18.9:1 TORTILLERIA PREP SALES LF-8 EM 8 0.81 37AbsoluteLITHONIA #GT8 8.0:1 11.8 fc 20.3 fc 1.5 fc 13.5:1 7.9:1 25.2 fc 35.3 fc 10.9 fc 3.2:1 2.3:1 22.2 fc 31.1 fc 7.8 fc 4.0:1 2.8:1 22.3 fc 37.7 fc 6.2 fc 6.1:1 3.6:1 9.8 fc 24.0 fc 1.1 fc 21.8:1 8.9:1 24.5 fc 48.7 fc 6.5 fc 7.5:1 3.8:1 LF-6 EM 9 0.70 64AbsoluteLITHONIA 2GT8-332-A12125 2X4 RECESSED LIGHT FIXTURE MVOLT-1/3-APNP LF-7 EM 4 0.70 64AbsoluteLITHONIA 2M-3-32-A12-MVOLT 2X4 RECESSED LIGHT FIXTURE APNP 2X2 RECESSED LIGHT FIXTURE 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 CL CL So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 CL CL So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 EXIT 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 PLAN CHECK NOTE: Likely 20A ckts, not 30. Verify attached equipment. HOLD- 420 W 17th St3/7/2025 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 01-11-2024 818-842-7285 01-11-2024 818-842-7285 MEL ANTHONY FAJARDO 1106 W. MAGNOLIA BLVD. SUITE A BURBANK, CA 91506 1106 W. MAGNOLIA BLVD. SUITE A BURBANK, CA 91506 E21979 PACIFIC ENGINEERING GROUP 420 W. 17TH STREET, SANTA ANA, CA 92706 HOLD- 420 W 17th St3/7/2025 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 01-11-2024 818-842-7285 01-11-2024 818-842-7285 MEL ANTHONY FAJARDO 1106 W. MAGNOLIA BLVD. SUITE A BURBANK, CA 91506 1106 W. MAGNOLIA BLVD. SUITE A BURBANK, CA 91506 E21979 PACIFIC ENGINEERING GROUP 420 W. 17TH STREET, SANTA ANA, CA 92706 HOLD- 420 W 17th St3/7/2025 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 FU1TX1 FUSE 1. LIGHTING CONTACTORS ARE WIRED IN PARALLEL BY ZONE. NOTES LIGHTING PANEL DIAGRAM LEGEND 2. WIRE 24 VOLT PILOT RELAYS TO APPROPRIATE TERMINAL BLOCKS IF REMOTE LIGHTING CONTACTORS ARE TO BE CONTROLLED. FU1 24V 120V TX2 LC LIGHTING CONTACTOR CONTACTOR CONTROL WIRING R1 FACTORY WIRING FIELD WIRING FUSE LEGEND FU1 KLDR-1 FU2 KLDR-1 FU2TX2 FUSE 3. BRANCH CIRCUIT PROTECTION PROVIDED AND INSTALLED BY E.C. FANS/ CABINETS LIGHTING RELAY L L N CONTROL BREAKER 120V L2 N 120V 1PH 60HZ BY E.C. SEE NOTES 3 & 4 L N C NC LCA1 A2 (SEE NOTE 1) C NC LCA1 A2 (SEE NOTE 1) CPC RELAY OUTPUT BOARD____ POINT_1__ RLRA1 A2 TRACK LIGHTS 24V PILOT RELAY (SEE NOTE 2) ZN3 C24V LC LC TO LIGHTING FIXTURES BY ELECTRICAL CONTRACTOR TO LIGHTING FIXTURES BY ELECTRICAL CONTRACTOR INDIVIDUAL LIGHTING CIRCUIT BREAKER BY ELECTRICAL CONTRACTOR. SEE LIGHTING PANEL SCHEDULE FOR SIZE, LOAD, AND PANEL LOCATION. 120 / 277V-1PH-60HZ BY ELECTRICAL CONTRACTOR R2 EXTERIOR LIGHT LIGHTING RELAY R3 SPARE LIGHTING RELAY TX1I/O BOARD TRANSFORMER TX2DIMMER MODULE TRANSFORMER RLRREMOTE LIGHTING RELAY (FIELD INSTALLED BY E.C.) (SEE NOTE 1)(SEE NOTE 1) 4. USE COPPER CONDUCTORS ONLY. SEE FIXTURE MANUFACTURER OPERATION MANUAL FOR WIRING DETAILS. ALL WIRING IS TO MEET OR EXCEED ALL LOCAL AND NATIONAL ELECTRICAL CODES. 16 CPC RELAY OUTPUT BOARD_1_6_ POINT_2__ WIRE NEUTRAL FOR ALL LIGHTING CONTACTOR COILS IN PARALLEL. L 120V L1 N 120V 1PH 60HZ BY E.C. SEE NOTES 3 & 4 GND ZONE 1 50% SALES LIGHTS LIGHTING CONTACTORS ZONE 2 50% SALES LIGHTS LIGHTING CONTACTORS C NC LCA1 A2 (SEE NOTE 1) CPC RELAY OUTPUT BOARD_1_6_ POINT_6__ ZONE 6 EXTERIOR LIGHTS LIGHTING CONTACTORS TOTAL CONTACTORS C NC LCA1 A2 (SEE NOTE 1) CPC RELAY OUTPUT BOARD_1_6_ POINT_7__ ZONE 7 SIGN LIGHTS LIGHTING CONTACTORS C NO CPC RELAY OUTPUT BOARD_1_6_ POINT_3__ RLRA1 A2 CASE LIGHTS 24V PILOT RELAY (SEE NOTE 2) ZN4 C24V C NO CPC RELAY OUTPUT BOARD_1_6_ POINT_4__ RLRA1 A2 CASE LIGHTS 1 24V PILOT RELAY (SEE NOTE 2) ZN5 C24V C NO CPC RELAY OUTPUT BOARD_1_6_ POINT_5__ 50VA ___2 TOTAL _2_ _ CONTACTORS TOTAL _3_ _ CONTACTORS TOTAL _3_ _ CONTACTORS WH I T E BL A C K YE L L O W BL U E TX3DIMMER MODULE TRANSFORMER FU3TX3 FUSE FU3 KLDR-1 GOODWINS CRESTLINE SEE LIGHTING PANEL SCHEDULE FOR SIZE, LOAD, AND PANEL LOCATION. 120 / 277V-1PH-60HZ BY ELECTRICAL CONTRACTOR GND 2. REMOTE LIGHTING RELAYS ARE 24VAC & FIELD INSTALLED BY E.C. AT OR NEAR REMOTE LIGHTING CONTACTORS. SEE PLANS FOR LOCATION OF REMOTE LIGHTING CONTACTORS. 1. BRANCH CIRCUIT PROTECTION DEVICE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR (E.C.) AS REQUIRED BY LOCAL & NATIONAL CODE. LEGEND NOTES 3. LIGHTING OVERRIDE SWITCHES ARE MOMENTARY NORMALLY OPEN (N.O.) DRY CONTACT SWITCHES. SEE PLANS FOR LOCATION. A2 + TERMINAL BLOCKS FIELD WIRING FACTORY WIRING LIGHTING PANEL DIMMER CONTROL DIAGRAM 120V 24V DIMMER MODULE TRANSFORMER FUSE L CPC MULTIFLEX 88AO BOARD CPC DIMMER MODULE CPC PART# 810-3048 N L N TX3 BL U E YE L L O W LIGHT BALLAST REFER TO BALLAST WIRING DIAGRAM FOR DETAILS. +- VI O L E T GR A Y DIMMER GRAY - VIOLET + CPC ISOLATOR (OPTIONAL) CPC PART# 250-2152 DIMMER MODULE TRANSFORMER 24V CT PINK PINK PURPLE GRAY PURPLE GRAY BLUE YELLOW 24V FROM TX1 (BOARD TRANSFORMER) BLUE YELLOW GND 120V FROM TX3 DIMMER MODULE TRANSFORMER FUSE L CONTROL BREAKER 120V L 120V 1PH 60HZ BY E.C. SEE NOTES 1 & 4N GND TO CPC E2 RS485 LOCAL NETWORK BLK YL W GR N RE D EXTERIOR CASES SALES INTERIOR LIGHTING OVERRIDE SWITCHES NOTE 3 EXTERIOR PHOTOCELL 4. USE COPPER CONDUCTORS ONLY. CUSTOMER NAME HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 VFD VARIABLE FREQUENCY DRIVE WT WP WATERTIGHT, WEIGHT WEATHER PROOF UNLESS OTHERWISE NOTED UNINTERRUPTIBLE POWER SUPPLY VOLT VOLT-AMPERE VACUUM VERTICAL VELOCITY VENT THROUGH ROOF VITRIFIED CLAY PIPE VARIABLE AIR VOLUME VOLUME DAMPER UNDERWRITERS LABORATORIES, INC. WITH WATT, WIDTH WITHOUT WET BULB WATER PRESSURE DROP TRANSFORMER UON UPS UL VAC VA V VD VEL VTR VERT VCP VAV W W/ W/O WPD WB XFMR SOUND LINED(SL) TSTAT TEMP INCHES OF WATER COLUMNIN WC SERVICE SINK STRUC STRUCTURAL POINT OF DISCONNECTIONPOD POC POINT OF CONNECTION AHU AIR HANDLING UNIT GRAVITY VENTILATORGV FC FAN COIL RTU ROOFTOP UNIT EF EXHAUST FAN FPI FINS PER INCH PRESS PRESSURE EXT EXTERNAL OSA OUTSIDE AIR APD DISCH DISCHARGE SYM SYMBOL PLUMBING PANEL POUNDS PER SQUARE INCH POUNDS PER SQUARE FOOT POLYVINYL CHLORIDE POUNDS PER SQUARE INCH GAUGE POUNDS PER SQUARE INCH ABSOLUTE QUANTITY ROOF DRAIN REINFORCING RECIRCULATE RETURN AIR REINFORCED CONCRETE PIPE REFLECTED CEILING PLAN, REFERENCE, REFER REQUIRED ROOM REVOLUTIONS PER MINUTE REFRIGERANT LIQUID REFRIGERANT SUCTION REVISION, REVISE SQUARE FEET SUPPLY AIR SIMILAR SHEET SECTION SPECIFICATION SHEET METAL CONDITIONING CONTRACTOR'S NATIONAL ASSOCIATION STATIC PRESSURE SMOKE DAMPER, STORM DRAIN SHEET METAL AND AIR SURFACE SUSPEND STANDARD STEEL THROUGH SOUND TRAP, STEAM TRAP TOTAL PRESSURE TOTAL DYNAMIC HEAD SQUARE STAINLESS STEEL, SANITARY SEWER, PSIA PSIG PLBG PSF PSI PNL PVC GAUGE GALLON GA GAL HEIGHTH GPH GPM GC GALV GPD GALVANIZED GALLONS PER DAY GALLONS PER HOUR GENERAL CONTRACTOR GALLONS PER MINUTE AIR PRESSURE DROP AMPERES ABOVE FINISHED GRADE ABOVE FINISHED FLOOR ABOVE FINISHED CEILING ARCHITECT, ARCHITECTURAL ADJUSTABLE AFF AFG ARCH ANSI AMPS ACCU AFC ADJ AIR COOLED CONDENSING UNIT AMERICAN NATIONAL STANDARDS INSTITUTE QTY RD RE: REINF RA RCP RL REV REQD RPM RS RM HEATING HEATER HERTZ HW HZ HORIZ HP HOA HVAC HTR HTG INCH ID IE IN (IN WG)INCHES WATER GAUGE HORSEPOWER, HEAT PUMP HORIZONTAL HOT WATER INSIDE DIAMETER INVERT ELEVATION HAND-OFF-AUTOMATIC HEATING, VENTILATING AND SF SIM SHT SA SECT SD SPEC SP SURF SUSP SS ST STL STD TP THRU TDH SQ KILOWATT KILOVOLTKV KWH KVA KW LENGTH POUND(S) LIGHTING L LF LAT LRA LDB LB(S),# LTG LWB LSTM KILOWATT-HOUR KILOVOLT-AMPS LINEAR FEET LEAVING DRY BULB LEAVING WET BULB LEAVING AIR TEMPERATURE LOCKED ROTOR AMPS LOW PRESSURE STEAM (15 PSIG) AND AIR CONDITIONING ENGINEERS AUXILIARY BUILDING BACKDRAFT DAMPER BOTTOM OF PIPE BOTTOM OF DUCT BOTTOM OF STRUCTURE BDD BOD BOP BOS BLDG ASHRAE ASME ASTM AUX BRITISH THERMAL UNIT CUBIC FEET PER SECOND CUBIC FEET PER MINUTE CUBIC FEET PER HOUR CIRCUIT CEILING CONDENSING UNIT COLUMN CONCRETE MASONRY UNIT COLD WATER CLEANOUT CENTERLINE CIRCULATING COL CW CU CO CKT CIRC LC CFH CFM CFS CLG CMU BTU AMERICAN SOCIETY OF HEATING, REFRIGERATION AMERICAN SOCIETY OF TESTING AND MATERIALS AMERICAN SOCIETY OF MECHANICAL ENGINEERS AIR CONDITIONING AND REFRIGERATION INSTITUTEARI SHT MTL SMACNA RECIRC THERMOSTAT TYPICAL UNDERSLAB UNDERGROUND UNDERFLOOR TOTAL STATIC PRESSURETSP TYP U/S U/F U/G MAXIMUM LWT MECH MFR MD MAX MBH MCA MOUNTED MINIMUM NEMA N/A NC NEC MIN MTD LEAVING WATER TEMPERATURE MECHANICAL MANUFACTURER MOTORIZED DAMPER NOT APPLICABLE MINIMUM CIRCUIT AMPACITY 1000 BTU PER HOUR NATIONAL ELECTRICAL CODE NOISE CRITERIA, NORMALLY CLOSED NATIONAL ELECTRICAL OBD OD OC OA NFPA N.O. NTS NIC OPENING OVERHEAD OSHA OH OPNG ON CENTER OUTSIDE AIR OUTSIDE DIAMETER OPPOSED BLADE DAMPER OCCUPATIONAL SAFETY NORMALLY OPEN NOT TO SCALE NOT IN CONTRACT ASSOCIATION NATIONAL FIRE PROTECTION MANUFACTURER'S ASSOCIATION DECIBEL DOWN DIAMETER DEGREES DISCONNECT DIMENSION DRY BULB DRAWING(S) EXHAUST AIR, EACH DIRECT EXPANSION ENTERING DRY BULB ENTERING AIR TEMPERATURE ECCENTRIC EAT EDB ECC EA DISC DN DIM DWG(S) DX dB DB DEG DIA EXISTING EXHAUST ENTERING WET BULB EXTERNAL STATIC PRESSURE EFFICIENCY ELECTRICAL EQUIPMENT ELEVATION DEGREES FAHRENHEIT FOOT, FEET FIRE ALARM FT ° F EXH EXIST, (E) FACP FA EQUIP EFF EL ESP EWB ELEC FIRE ALARM CONTROL PANEL TEMPERATURE SFD (COMBINATION) SMOKE-FIRE DAMPER OVERFLOWOF M/U MAKE-UP FD FIRE DAMPER D/P DIFFERENTIAL PRESSURE B BOILER ABBREVIATIONS V W X G H R S I T K L B C Q U M N O E F D A P COMBINATION FIRE/SMOKE DAMPERCFSD FIRE SMOKE DAMPERFSD NK NECK SIZE TRANSFERTR EXHAUST AIR GRILLEEAG EXHAUST AIR REGISTEREAR RETURN AIR GRILLERAG RETURN AIR REGISTERRAR SUPPLY AIR REGISTERSAR DOOR LOUVERDL DOOR UNDERCUTUC SHEET INDEX SHT.NO.DESCRIPTION M1.0 MECHANICAL NOTES AND LEGENDS AIR CONDITIONING AND ADMINISTRATION CODE AND STANDARDS SD H C 1 M-100 X X 1/M-100 DETAIL DESIGNATION DRAWING WHERE DETAIL IS SHOWN DIFFUSER, GRILLE OR REGISTER MARK (SEE SCHEDULE) EQUIPMENT MARK (SEE SCHEDULE) DETAIL DESIGNATION LOCATOR/DESCRIPTOR DRAWING WHERE DETAIL IS SHOWN OR WHERE DETAIL IS REFERENCED FROM SECTION CUT LOCATOR/DESCRIPTOR DRAWING WHERE SECTION IS SHOWN OR WHERE DETAIL IS REFERENCED FROM MATCH LINE EQUIPMENT TAG FOR VRF SYSTEM FAN COILS ASSOCIATED BRANCH CONTROL CIRCUIT ASSOCIATED VRF CONDENSING UNIT 12"Ø 20x12 DN UP S (ZONE) T (ZONE) MANUAL VOLUME DAMPER COMBINATION SMOKE/FIRE DAMPER SUPPLY AIR DIFFUSER - ARROWS INDICATE PATTERN. NO PATTERN SHOWN EQUALS 4-WAY RETURN AIR GRILLE EXHAUST GRILLE (L) INDICATE ACOUSTICAL LINER(SINGLE LINE) RELIEF OR EXHAUST AIR DUCT RETURN AIR DUCT SUPPLY OR OUTSIDE AIR DUCT SUPPLY OR OUTSIDE AIR DUCT DOWN RETURN AIR DUCT DOWN SUPPLY OR OUTSIDE AIR DUCT UP RETURN AIR DUCT UP ROUND DUCT BRANCH TAKE-OFF FROM RECTANGULAR MAIN WITH CONICAL TAP. DUCTWORK SIZE TRANSITION RECTANGULAR DUCTWORK. SIZE INDICATED IN INCHES, FIRST NUMBER IS TOP OR BOTTOM SHOWN (SINGLE LINE) ROUND DUCTWORK (SINGLE LINE) RELIEF OR EXHAUST AIR DUCT DOWN IN-LINE 90 DEGREE DROP (RISE) IN DUCT TURNING VANES INCLINED DROP IN DUCT INCLINED RISE IN DUCT NEW DUCTWORK (SINGLE LINE) EXISTING DUCTWORK (SINGLE LINE) RELIEF OR EXHAUST AIR DUCT UP RETURN AIR BOOT MOTORIZED DAMPER FLEXIBLE DUCT (SINGLE PIECE, 7 FEET MAX.) TEMPERATURE SENSOR (MOUNT 46" AFF) BACKDRAFT DAMPER ROOM THERMOSTAT (MOUNT 46" AFF) HVAC SYMBOLS HUMIDISTAT (MOUNT 96" AFF) DUCT SMOKE DETECTOR POINT OF NEW CONNECTION DEMOLITION NOTE CO2 SENSOR (MOUNT 96'' AFF) KEYED NOTE POINT OF DISCONNECTION FCV-X VCU BC BAROMETRIC RELIEF DAMPER AHU 1 1 M-10 X (L) 3. 2. 1. 4. SEISMIC RESTRAINT NOTES SCOPE SEISMIC RESTRAINT GUIDELINES PIPING ·SEISMICALLY BRACE INDIVIDUALLY SUPPORTED PIPING GREATER THAN 3" IN DIAMETER. ·SEISMICALLY BRACE TRAPEZE ASSEMBLIES IF PIPING IS GREATER THAN 10 LB/FT. DUCTWORK ·SEISMICALLY BRACE DUCTWORK 6' SQUARE FEET OR GREATER OR 17 LB/FT OR MORE. EQUIPMENT · ·SEISMICALLY BRACE EQUIPMENT HUNG FROM THE STRUCTURE 2O LBS OR MORE. FIRE LIFE SAFETY NOTES THE ELECTRICAL CONTRACTOR SHALL INTERCONNECT ALL FANS AND AC UNITS WITH THE BUILDING LIFE SAFETY SYSTEM FOR UNIT SHUT DOWN UPON A SIGNAL FROM THE LIFE SAFETY SYSTEM. WHERE DUCT MOUNTED SMOKE DETECTORS FOR FANS AND AC UNITS ARE REQUIRED, THE HVAC CONTRACTOR SHALL FURNISH AND INSTALL THE SMOKE DETECTORS, THE ELECTRICAL CONTRACTOR PROVIDE ALL WIRING AND CONDUIT TO SIGNAL THE LIFE SAFETY SYSTEM. THE LIFE SAFETY SYSTEM SHALL SHUT DOWN THE EXHAUST FANS OR AC UNITS AS DESCRIBED IN NOTE #1. ALL SMOKE DETECTORS SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATION AND SHALL BE COMPATIBLE WITH WITH THE BASE BUILDING STANDARDS. EACH SINGLE SYSTEM PROVIDING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM OR 54,000 BTU SHALL BE EQUIPPED WITH AN AUTOMATIC SHUT-OFF. THE SMOKE DETECTOR SHALL BE INSTALLED IN THE MAIN SUPPLY AIR DUCT DOWNSTREAM OF THE FILTERS OR THEY MAY BE INSTALLED IN EACH ROOM OR SPACE SERVED BY THE SUPPLY AIR DUCT. DETECTORS SHALL ALSO BE INSTALLED IN THE MAIN RETURN DUCT (IF REQ'D. BY THE LOCAL CODE) AHEAD OF OSA INTAKE. SEE CODE FOR EXEMPTIONS AND LOCAL AUTHORITY FOR CODE INTERPRETATION, OR AS INDICATED ON PLAN. SEISMIC RESTRAINT SYSTEMS FOR PIPING, DUCTWORK AND EQUIPMENT IS A DELEGATED DESIGN. THE GENERAL REQUIREMENTS PRESENTED BELOW ARE NOT ALL-INCLUSIVE AND REPRESENT SIMPLIFIED REQUIREMENTS BASED ON THE CRITERIA LISTED BELOW. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DESIGN A SYSTEM THAT IS IN FULL COMPLIANCE WITH THE LISTED CRITERIA . EXCEPTION: DUCTWORK SUSPENDED 12” OR LESS FROM THE SUPPORTING STRUCTURE SEISMICALLY BRACE EQUIPMENT 400 LBS OR MORE WITH A CENTER OF MASS AT 4FT OR LESS TO THE FINISHED FLOOR EXCEPTION: HANGERS IN THE PIPING RUN ARE 12” OR LESS FROM TOP OF THE TRAPEZE BAR TO THE SUPPORTING STRUCTURE. EXCEPTION: PIPING SUPPORTED BY ROD WITHIN 12” OF THE SUPPORTING STRUCTURE. 1.MECHANICAL CONTRACTOR SHALL GUARANTEE THE ENTIRE HEATING, VENTILATING AND AIR CONDITIONING SYSTEM FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF PRACTICAL COMPLETION. IF, DURING THIS PERIOD, ANY MATERIALS OR APPARATUS PROVE DEFECTIVE OR ANY PART OF THE SYSTEM FAILS TO FUNCTION PROPERLY, CONTRACTOR SHALL PROVIDE PARTS AND LABOR TO RECTIFY PROBLEMS WITHOUT EXPENSE TO OWNER. 2.ALL A/C COMPRESSORS SHALL HAVE FULL 5 YEAR NON-PRO RATED WARRANTY FOR REPLACEMENT WITH NEW COMPRESSORS. ALL A/C UNITS HEAT EXCHANGERS SHALL BE WARRANTED AGAINST DEFECTS FOR A TEN (10) YEAR PERIOD. PROVIDE ANTI-SHORT CYCLING FEATURE FOR COMPRESSORS. 3.FURNISH OWNER WITH ALL MANUFACTURERS WRITTEN GUARANTEES OF MATERIAL AND EQUIPMENT AS CONDITION OF FINAL PAYMENT. WARRANTY INFORMATION 1.METAL DUCT: SHEET METAL DUCTWORK CONSTRUCTION TO COMPLY WITH THE LOS ANGELES CITY MECHANICAL CODE AND SMACNA GUIDE LINE, WHICHEVER PROVIDES THE STRONGER DUCT CONSTRUCTION. 2.FLEXIBLE DUCT: FLEXIBLE ROUND DUCT SHALL NOT BE LONGER THAN 5'-0" LONG IN FULLY EXTENDED INSTALLED CONDITION WITH MINIMUM NUMBER OF BENDS. (NOTE: NO ALUMINUM FLEX DUCT IS TO BE USED IN THIS PROJECT.) 3.DUCT ACCESSORIES: PROVIDE APPROVED DUCT TAPE OR CLAMP FOR FLEX TO DUCT CONNECTION. ALL SHEET METAL SHALL HAVE A MIN. OF 2" COLLAR ON 4" SLEEVES USED TO JOIN THE FLEXIBLE DUCT ATTACHMENT. ALL DUCT JOINTS SHALL BE SEALED WITH AN APPROVED TYPE MASTIC. 4.DUCT INSULATION: DUCT INSULATION TO BE FIBERGLASS 3/4 P.C.F. DENSITY AND R8 OUTDOORS AND SPACE DIRECTLY UNDER A ROOF WITH FIXED VENTS AND R4.2 IN CONDITIONED OR INDIRECTLY CONDITIONED SPACE. 5.HANGERS: DUCTWORK LESS THAN 48" X 24" SHALL BE SUPPORTED WITH A MINIMUM OF 2" X 1-1/2" INCH WIDE CHANNELS AND 1" HANGER STRAP AS REQUIRED BY UMC TABLE A6-5E AND F. FOR DETAIL SPECIFICATION OF MATERIAL, PRODUCT AND EXECUTION REFER TO BOOKLET SPECIFICATION. SPECIFICATION MECHANICAL NOTES THE HVAC SYSTEM WILL BE DESIGNED TO CONFORM, AT A MINIMUM, TO THE FOLLOWING CODES AND STANDARDS: ·BUILDING STANDARDS ADMINISTRATIVE CODE (2022) ·ASHRAE FUNDAMENTALS HANDBOOK (2013) ·ASHRAE HVAC APPLICATIONS HANDBOOK (2011) ·ASHRAE HVAC SYSTEMS AND EQUIPMENT HANDBOOK (2012) ·ASHRAE 62.1 - VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY (2019) ·ASHRAE 62.2 - VENTILATION AND ACCEPTABLE INDOOR AIR QUALITY IN LOW-RISE RESIDENTIAL BUILDINGS (2019) ·ASHRAE 90.1 - ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS (2010) ·ASHRAE GUIDELINE 1 - THE HVAC COMMISSIONING PROCESS (2007) ·CALIFORNIA BUILDING CODE (2022) ·CALIFORNIA MECHANICAL CODE (2022) ·CALIFORNIA PLUMBING CODE (2022) ·CALIFORNIA ENERGY CODE (2022) ·CALIFORNIA GREEN BUILDING STANDARD CODE (2022) ·CALIFORNIA ELECTRICAL CODE (2022) ·CALIFORNIA RESIDENTIAL CODE (2022) ·CALIFORNIA FIRE CODE (2022) ·UNIFORM PLUMBING CODE (2022) ·NFPA 90A - INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS (2015) ·SMACNA HVAC DUCT CONSTRUCTION STANDARDS: METAL AND FLEXIBLE ·SMACNA HVAC SYSTEMS DUCT DESIGN ·SMACNA SEISMIC RESTRAINT MANUAL FOR MECHANICAL SYSTEMS MUA MAKE-UP AIR MECHANICAL FLOOR PLAN M1.1 M2.0 MECHANICAL EQUIPMENT SCHEDULESM1.2 MECHANICAL DETAILSM4.0 SUPPLY WALL REGISTERSWR MECHANICAL ROOF PLANM3.0 CAPTIVEAIRE DRAWINGSM5.0 MECHANICAL DETAILSM4.1 CAPTIVEAIRE DRAWINGSM5.1 CAPTIVEAIRE DRAWINGSM5.2 CAPTIVEAIRE DRAWINGSM5.3 ENERGY COMPLIANCEM1.4 ENERGY COMPLIANCEM1.5 TAG TRANSFER AIR GRILLE MECHANICAL EQUIPMENT SCHEDULESM1.3 ENERGY COMPLIANCEM1.6 INSTALL NEW AIR HANDLING UNIT, CONDENSING UNITS, PACKAGED AC UNITS, FANS, DUCTWORK, AND TYPE I HOODS. SCOPE OF WORK HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 GENERAL NOTES THE FOLLOWING NOTES (ITEMS) REPRESENT THE MANDATORY REQUIREMENTS FOR ALL BUILDINGS. TITLE 24 REQUIREMENTS 1. DOORS AND WINDOWS SHALL MEET THE MINIMUM INFILTRATION REQUIREMENTS PER SECTION 110.6 AND 110.7 E.E.S. 2. ALL ENVELOPE AND MECHANICAL CERTIFICATE OF ACCEPTANCE FORMS AND ALL RELATED ACCEPTANCE DOCUMENTS SHALL BE SUBMITTED TO THE FIELD INSPECTOR DURING CONSTRUCTION. CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THESE FORMS ARE REVIEWED AND APPROVED. 3. ALL PIPING AND DUCT WORK SHALL BE INSULATED CONSISTENT WITH THE REQUIREMENTS OF SECTIONS 120.3, 120.4, AND 120.7 TITLE 24 ENERGY STANDARDS AND CHAPTER 6 OF CMC. 4. ALL HVAC SYSTEMS SHALL MEET THE CONTROL REQUIREMENTS PER SECTION 110.2 AND 120.2 E.E.S. 5. ALL HVAC EQUIPMENT AND APPLIANCES SHALL MEET THE REQUIREMENTS PER SECTION 110.1 -110.3, 110.5, 120.1-120.4 TITLE-24 ENERGY STANDARDS. 6. INSULATION MATERIAL SHALL MEET THE CALIFORNIA QUALITY STANDARD PER SECTION 110.8 ENERGY EFFICIENCY STANDARDS (E.E.S.) 7, THE PERSON WITH OVERALL RESPONSIBILITY FOR CONSTRUCTION OR THE PERSON RESPONSIBLE FOR THE INSTALLATION OF REGULATED FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES SHALL POST, OR MAKE AVAILABLE WITH THE BUILDING PERMIT(S) ISSUED FOR THE BUILDING, THE REQUIRED INSTALLATION CERTIFICATE(S) FOR FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES REGULATED BY THE APPLIANCE EFFICIENCY REGULATIONS OR PART 6. SUCH INSTALLATION CERTIFICATE(S) SHALL BE MADE AVAILABLE TO THE ENFORCEMENT AGENCY FOR ALL APPROPRIATE INSPECTIONS. THESE CERTIFICATES SHALL: I. IDENTIFY FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES REQUIRED TO VERIFY COMPLIANCE WITH THE APPLIANCE EFFICIENCY REGULATIONS AND PART 6. II. INCLUDE A STATEMENT INDICATING THAT THE FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVISE CONFORM TO THE APPLIANCE EFFICIENCY REGULATIONS AND PART 6 AND THE REQUIREMENTS FOR SUCH FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES GIVEN IN THE PLANS AND SPECIFICATIONS APPROVED BY THE LOCAL ENFORCEMENT AGENCY. III. STATE THE NUMBER OF THE BUILDING PERMIT UNDER WHICH THE CONSTRUCTION OR INSTALLATION WAS PERFORMED. 8. WITHIN 90 DAYS AFTER ISSUANCE OF CERTIFICATE OF OCCUPANCY RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER. IF A BUILDING DESIGN FEATURE, MATERIAL, COMPONENT OR MANUFACTURED DEVICE IS CHANGED BEFORE FINAL CONSTRUCTION AND INSTALLATION, SUCH THAT THE BUILDING MAY NO LONGER COMPLY WITH PART 6, THE BUILDING MUST BE BROUGHT INTO COMPLIANCE, AND SO INDICATED ON AMENDED PLANS AND CERTIFICATE OF COMPLIANCE(S) THAT SHALL BE SUBMITTED FOR APPROVAL. 9, THE BUILDER SHALL PROVIDE THE BUILDING OWNER OR PERSON(S) RESPONSIBLE FOR BUILDING MAINTENANCE AT THE OCCUPANCY THE FOLLOWING: I.OPERATING INFORMATION: THE APPROPRIATE CERTIFICATE(S) OF COMPLIANCE AND A LIST OF THE FEATURES, MATERIALS, COMPONENTS, AND MECHANICAL DEVICES INSTALLED IN THE BUILDING AND INSTRUCTIONS ON HOW TO OPERATE THEM EFFICIENTLY. II. MAINTENANCE INFORMATION: REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING THE OPERATION AND MAINTENANCE MANUAL. III. VENTILATION INFORMATION: A DESCRIPTION OF THE QUANTITIES OF OUTDOOR AND RE-CIRCULATED AIR THAT THE VENTILATION SYSTEMS ARE DESIGNED TO PROVIDE TO EACH AREA. 10. THE LESSER OF THE MINIMUM RATE OR OUTDOOR AIR REQUIRED BY SEC 120.1(c), OR THREE COMPLETE AIR CHANGES SHALL BE SUPPLIED TO THE ENTIRE BUILDING DURING THE ONE-HOUR PERIOD IMMEDIATELY BEFORE THE BUILDING IS NORMALLY OCCUPIED. 11. ALL MECHANICAL VENTILATION AND SPACE-CONDITIONING SYSTEMS SHALL BE DESIGNED WITH DUCTWORK, DAMPERS, AND CONTROLS WHICH ALLOWS OUTSIDE AIR RATES TO BE OPERATED AT THE LARGER OF (1)THE MINIMUM LEVELS SPECIFIED IN SECTION 120.1(c)3 OR (2)THE RATE REQUIRED FOR MAKE-UP OF EXHAUST SYSTEMS THAT ARE REQUIRED FOR AN EXEMPT OR COVERED PROCESS, FOR CONTROL OF ODORS, OR FOR THE REMOVAL OF CONTAMINANTS WITHIN THE SPACE. MEASURED OUTSIDE AIR RATES OF CONSTANT AND VARIABLE VOLUME MECHANICAL VENTILATION SYSTEMS SHALL BE WITHIN 10% OF OUTSIDE AIR RATE SHOWN ON TABLE 120.1-A. 12. THE THERMOSTATIC CONTROLS FOR HVAC SYSTEMS SHALL BE CAPABLE OF BEING SET LOCALLY OR REMOTELY BY TO CONTROL COMFORT HEATING DOWN TO 55°F OR LOWER AND COOLING UP TO 85°F OR HIGHER. THE THERMOSTATIC CONTROLS SHALL BE CAPABLE OF PROVIDING A DEAD BAND RANGE OF AT LEAST 5°F WITHIN WHICH HEATING AND COOLING ENERGY TO THE ZONE IS SHUT-OFF OR REDUCE TO A MINIMUM. 13. OUTDOOR AIR SUPPLY AND EXHAUST EQUIPMENT SHALL BE INSTALLED WITH DAMPERS THAT AUTOMATICALLY CLOSE UPON FAN SHUTDOWN. 14, SPACE CONDITIONING SYSTEMS WITH DDC ZONE CONTROLS SHALL HAVE OPTIMUM START/STOP CONTROLS. MINIMUM CONTROLS SHOULD FUNCTION THE DIFFERENCE(S) BETWEEN SPACE TEMPERATURE(S) AND OCCUPIED SET POINT(S), THE OUTDOOR AIR TEMPERATURE(S), AND THE AMOUNT OF TIME PRIOR TO SCHEDULED OCCUPANCY. 15. EACH SPACE-CONDITIONING SYSTEM SHALL BE INSTALLED WITH CONTROLS (1)CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SYSTEM DURING PERIODS OF NON-USE AND SHALL HAVE (A) 4-HR TIMER OR; (B) OCCUPANCY SENSORS OR; (C) AUTO-TIME SWITCH CONTROLS AND ACCESSIBLE MANUAL OVERRIDE FOR UP TO 4-HRS. (2)AUTOMATICALLY RE-START AND TEMPORARILY OPERATE THE SYSTEM TO MAINTAIN SETBACK THERMOSTAT SETPOINTS FOR MECHANICAL HEATING AND COOLING. (3)MULTIPURPOSE, CLASSROOMS, CONFERENCE, CONVENTION, AUDITORIUM, AND MEETING CENTER ROOMS OF CERTAIN SIZE WHICH DO NOT HAVE PROCESSES OR OPERATIONS THAT GENERATE DUSTS, FUMES, VAPORS OR GASSES SHALL BE EQUIPPED WITH OCCUPANT SENSOR(S) TO ACCOMPLISH THE FOLLOWING DURING UNOCCUPIED PERIODS (A)AUTOMATICALLY SET-UP THE OPERATING COOLING TEMPERATURE SET POINT BY 2°F OR MORE AND SETBACK THE OPERATING HEATING TEMPERATURE SET POINT BY 2°F OR MORE AND: (B)AUTOMATICALLY RESET THE MINIMUM REQUIRED VENTILATION RATE WITH AN OCCUPANT SENSOR VENTILATION CONTROL DEVICE ACCORDING TO SECTION 120.1(c)5. 14, ALL ENCLOSED SPACES IN A BUILDING THAT ARE NORMALLY USED BY HUMANS SHALL BE VENTILATED IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 121. 15. ALL FAN SYSTEMS EXHAUSTING AIR FROM THE BUILDING TO THE OUTSIDE SHALL BE PROVIDED WITH BACKDRAFT OR AUTOMATIC DAMPERS TO PREVENT AIR LEAKAGE. 16. DUCT SYSTEMS SHALL COMPLY WITH UL 181, INCLUDING ALL COLLARS, CONNECTIONS AND SPLICES. ALL PRESSURE-SENSITIVE TAPES, HEAT-ACTIVATED TAPES AND MASTICS SHALL COMPLY WITH UL 181, UL 181A, OR UL181B 17. ALL THERMOSTATS SHALL HAVE A DEADBAND BETWEEN HEATING AND COOLING, CAPABLE OF ADJUSTMENT UP TO 10°F. 18. ALL EQUIPMENT DESIGNED TO BE FIXED IN POSITION SHALL BE SECURELY FIXED IN PLACE, AND IN ACCORDANCE WITH SEISMIC REQUIREMENTS. 19. REQUIRED ROUTINE MAINTENANCE ACTION SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE PERMANENT LABEL. THE LABEL MAY BE LIMITED TO CROSS REFERENCING THE MAINTENANCE MANUAL IF SUCH MAINTENANCE ACTION IS DESCRIBED THEREIN FOR THE LABELED ITEM. 20. ALL EQUIPMENT SHALL CONFORM TO AND BE CERTIFIED IN ACCORDANCE WITH THE APPLIANCE STANDARDS AND THE REQUIREMENTS FOR SUCH DEVICES GIVEN IN THE PLANS AND SPECIFICATIONS APPROVED BY THE LOCAL ENFORCEMENT AGENCY. 21. ALL EQUIPMENT SHALL BE LABELED AS TO FUNCTION AND SPACES SERVED. (SEE SCHEDULE) EQUIPMENT AND SYSTEMS EFFICIENCY ANY APPLIANCE FOR WHICH THERE IS A CALIFORNIA STANDARD ESTABLISHED IN THE APPLIANCE EFFICIENCY STANDARDS MAY BE INSTALLED ONLY IF THE MANUFACTURER HAS CERTIFIED TO THE COMMISSION, AS SPECIFIED IN THOSE REGULATIONS, THAT THE APPLIANCE COMPLIES WITH THE APPLICABLE STANDARD FOR THAT APPLIANCE. INCLUDED ARE ROOM AIR CONDITIONERS, CENTRAL AIR CONDITIONING HEAT PUMPS (REGARDLESS OF CAPACITY, EXCEPT THAT REQUIREMENTS FOR CENTRAL AIR CONDITIONING HEAT PUMPS WITH COOLING CAPACITY OF 135,000 BTU/HR OR MORE APPLY TO HEATING PERFORMANCE BUT NOT COOLING PERFORMANCE), OTHER CENTRAL AIR CONDITIONERS WITH A COOLING CAPACITY LESS THAN 135,000 BTU/HR, FAN TYPE CENTRAL FURNACES WITH INPUT RATE LESS THAN 400,000 BTU/HR, BOILERS WALL FURNACES, FLOOR FURNACES, ROOM HEATERS, UNIT HEATERS, AND DUCT FURNACES SHALL HAVE BEEN CERTIFIED TO THE CALIFORNIA ENERGY COMMISSION BY ITS MANUFACTURER TO COMPLY WITH THE APPLIANCE EFFICIENCY STANDARDS. THE FOLLOWING SPACE CONDITIONING EQUIPMENT MAY BE INSTALLED ONLY IF THE MANUFACTURER HAS CERTIFIED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL APPLICABLE EFFICIENCY REQUIREMENTS LISTED IN 112 OF THE ENERGY EFFICIENCY STANDARDS: ALL AIR CONDITIONERS, HEAT PUMPS AND CONDENSING UNITS 135,000 BTU/HR; ALL WATER CHILLERS; ALL GAS-FIRED BOILERS 300,000 BTU/HR; ALL OIL-FIRED BOILERS 225,000 BTU/HR; AND ALL WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/ AIR-CONDITIONING UNITS 225,000 BTU/HR. FAN TYPE CENTRAL FURNACES SHALL NOT HAVE A PILOT LIGHT. PIPING, EXCEPT THOSE CONVEYING FLUIDS AT TEMPERATURES BETWEEN 60° F AND 105° F, OR WITHIN HVAC EQUIPMENT, SHALL BE INSULATED IN ACCORDANCE WITH STANDARDS 123. AIR HANDLING DUCT SYSTEMS SHALL BE CONSTRUCTED, INSTALLED, SEALED, AND INSULATED IN COMPLIANCE WITH WITH SECTIONS 601, 602, 603, 604, AND 605 OF 2019 CMC STANDARDS. (NO DUCT TAPE ALLOWED). CONTROLS EACH SPACE CONDITIONING SYSTEM SHALL BE INSTALLED WITH ONE OF THE FOLLOWING: O EACH SPACE CONDITIONING SYSTEM SERVING BUILDINGS (AND ALL OTHERS NOT EXPLICITLY EXEMPT FROM THE REQUIREMENTS OF SECTION 112(D)) SHALL BE INSTALLED WITH AN AUTOMATIC TIME SWITCH WITH AN ACCESSIBLE MANUAL OVERRIDE THAT ALLOWS OPERATION OF THE SYSTEM DURING OFF-HOURS FOR UP TO 4 HOURS. THE TIME SWITCH SHALL BE CAPABLE OF PROGAMMING DIFFERENT SCHEDULES FOR WEEKDAYS AND WEEKENDS; INCORPORATE AN AUTOMATIC HOLIDAY "SHUT-OFF" FEATURE THAT TURNS OFF ALL LOADS FOR AT LEAST 24 HOURS, THEN RESUMES THE NORMALLY SCHEDULED OPERATION; AND HAS PROGRAM BACKUP CAPABILITIES THAT PREVENT THE LOSS OF THE DEVICE'S PROGRAM AND TIME SETTING FOR AT LEAST 10 HOURS IF POWER IS INTERRUPTED. O EACH SPACE CONDITIONING SYSTEM SHALL BE INSTALLED WITH AN OCCUPANCY SENSOR TO CONTROL THE OPERATING PERIOD OF THE SYSTEM. O EACH SPACE CONDITIONING SYSTEM SHALL BE INSTALLED WITH A 4-HOUR TIMER THAT CAN BE MANUALLY OPERATED TO CONTROL THE OPERATING PERIOD OF THE SYSTEM. O EACH SPACE CONDITIONING SYSTEM SHALL BE INSTALLED WITH CONTROLS THAT TEMPORARILY RESTART AND TEMPORARILY OPERATE THE SYSTEM AS REQUIRED TO MAINTAIN A SETBACK HEATING AND/OR A SETUP COOLING THERMOSTAT SETPOINT. O THERMOSTATS SHALL HAVE NUMERIC SETPOINTS IN ° F AND ADJUSTABLE SETPOINT STOPS ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL. O EACH SPACE CONDITIONING SYSTEM SERVING MULTIPLE ZONES WITH A COMBINED CONDITIONING FLOOR AREA MORE THAN 25,000 SQ.FT. SHALL BE PROVIDED WITH ISOLATION ZONES. EACH ZONE SHALL : NOT EXCEED 25,000 SQ.FT.; SHALL BE PROVIDED WITH ISOLATION DEVICES, SUCH AS VALVES OR DAMPERS, THAT ALLOW THE SUPPLY OF HEATING OR COOLING TO BE SETBACK OR SHUT OFF INDEPENDENTLY OF OTHER ISOLATION AREAS; AND SHALL BE CONTROLLED BY A TIME CONTROL DEVICE AS DESCRIBED ABOVE. O EACH SPACE CONDITIONING ZONE SHALL BE CONTROLLED BY AN INDIVIDUAL THERMOSTATIC CONTROL THAT RESPONDS TO TEMPERATURE WITHIN THE ZONE. WHERE USED TO CONTROL HEATING, THE CONTROL SHALL BE ADJUSTABLE DOWN TO 55° F OR LOWER. FOR COOLING, THE CONTROL SHALL BE ADJUSTABLE UP TO 85° F OR HIGHER. WHERE USED TO CONTROL BOTH HEATING AND COOLING, THE CONTROL SHALL BE CAPABLE OF PROVIDING A DEAD BAND OF AT LEAST 5° F WITHIN WHICH THE SUPPLY OF HEATING AND COOLING IS SHUT OFF OR REDUCED TO A MINIMUM. O HEAT PUMPS SHALL BE INSTALLED WITH CONTROLS TO PREVENT ELECTRIC RESISTANCE SUPPLEMENTARY HEATER OPERATION WHEN THE HEATING LOAD CAN BE MET BY THE HEAT PUMP ALONE. ELECTRIC HEATING LOAD CAN BE MET BY THE HEAT PUMP ALONE. ELECTRIC RESISTANCE SUPPLEMENTARY HEATER OPERATION IS PERMITTED DURING TRANSIENT PERIODS, SUCH AS START-UPS AND FOLLOWING ROOM THERMOSTAT SETPOINT ADVANCE, WHEN CONTROLS ARE PROVIDED WHICH USE PREFERENTIAL RATE CONTROL, INTELLIGENT RECOVERY, STAGING, RAMPING, OR SIMILAR CONTROL MECHANISMS DESIGNED TO PRECLUDE THE UNNECESSARY OPERATION OF SUPPLEMENTARY HEATING DURING THE RECOVERY PERIOD. SUPPLEMENTARY HEATER OPERATION IS ALSO PERMITTED DURING DEFROST. VENTILATION O CONTROL SHALL BE PROVIDED TO ALLOW OUTSIDE AIR DAMPERS OR DEVICES TO BE OPERATED AT THE VENTILATION RATES AS SPECIFIED ON THESE PLANS. O GRAVITY OR AUTOMATIC DAMPERS INTERLOCKED AND CLOSED ON FAN SHUTDOWN SHALL BE PROVIDED ON THE OUTSIDE AIR INTAKES AND DISCHARGES OF ALL SPACE CONDITIONING AND EXHAUST SYSTEMS. O ALL GRAVITY VENTILATING SYSTEMS SHALL BE PROVIDED WITH AUTOMATIC OR READILY ACCESSIBLE MANUALLY OPERATED DAMPERS IN ALL OPENINGS TO THE OUTSIDE, EXCEPT FOR COMBUSTION AIR OPENINGS. O AIR BALANCING: ALL SPACE CONDITIONING AND VENTILATION SYSTEMS SHALL BE BALANCED TO THE QUANTITIES SPECIFIED IN THESE PLANS, IN ACCORDANCE WITH THE NATIONAL ENVIRONMENTAL BALANCING BUREAU(NEBB) PROCEDURAL STANDARDS(1983), OR ASSOCIATED AIR BALANCE COUNCIL (AABC) NATIONAL STANDARDS (1986). O OUTSIDE AIR CERTIFICATION: THE SYSTEM SHALL PROVIDE THE MINIMUM OUTSIDE AIR AS SHOWN ON THE MECHANICAL DRAWINGS, AND SHALL BE MEASURED AND CERTIFIED BY THE INSTALLING LICENSED C-20 MECHANICAL CONTRACTOR AND CERTIFIED BY (1) THE DESIGN MECHANICAL ENGINEER, (2) THE INSTALLING LICENSED C-20 MECHANICAL CONTRACTOR, OR (3) THE PERSON WITH OVERALL RESPONSIBILITY FOR THE DESIGN OF THE VENTILATION SYSTEM. O OUTSIDE AIR MEASUREMENT: THE SYSTEM SHALL BE EQUIPPED WITH A CALIBRATED LOCAL OR REMOTE DEVICE CAPABLE OF MEASURING THE QUANTITY OF OUTSIDE AIR ON A CONTINUOUS BASIS AND DISPLAYING THAT QUANTITY ON A READILY ACCESSIBLE DISPLAY DEVICE. O ANOTHER METHOD APPROVED BY THE COMMISION. MECHANICAL MANDATORY MEASURES 1. ENERGY EFFICIENCY COMPLIANCE PROVIDED IN ACCORDANCE WITH MINIMUM REQUIREMENTS. 2. A COPY OF THE CONSTRUCTION DOCUMENTS OR A COMPARABLE DOCUMENT INDICATING THE INFORMATION FROM ENERGY CODE SECTION 110.10(B) THROUGH 110.10(C) SHALL BE PROVIDED TO THE OCCUPANT. (ENERGY CODE 110.10(D) 3. AFTER FUNCTIONAL PERFORMANCE TESTS ARE CONCLUDED, FORM GRN24 SHALL BE COMPLETED AND READILY AVAIALABLE TO THE FIELD INSPECTIOR PRIOR TO FINAL APPROVAL. (5.410.2.4) 4. ALL OPERATIONAL ASPECTS OF THE BUILDING SHALL BE DOCUMENTED WITHIN A SYSTEMS MANUAL. THIS SYSTEMS MANUAL SHALL BE DELIVERED TO THE OWNER OR REPRESENTATIVE. (5.410.2.5.1) 5. THE TRAINING OF THE APPROPRIATE MAINTENANCE STAFF FOR EACH EQUIPMENT TYPE AND/OR SYSTEM SHALL BE DOCUMENTED IN THE COMMISSIONING REPORT (5.410.2.5.2). 6. FORM GRN 25 SHALL BE COMPLETED AND READILY AVAILABLE TO THE FIELD INSPECTOR PRIOR TO FINAL APPROVAL. 7. A COMPLETE COMMISSIONING REPORT AND FORM GRN 26 (COMPLETED0 SHALL BE PROVIDED TO THE OWNER OR REPRESENTATIVE AND WILL BE READILY AVAILABLE TO THE FIELD INSPECTOR PRIOR TO THE FINAL APPROVAL. (5.410.2.6, 5.410.4.4). 8. TESTING AND ADJUSTMENT IS REQUIRED FOR ALL NEW INSTALLATION OF ANY OF THE FOLLOWING SYSTEMS: A.RENEWABLE ENERGY SYSTEMS. I. DESCRIBE THE TYPE OF SYSTEM (E.G. SOLAR PHOTOVOLTAIC, WIND TURBINES, ETC...) II. PROVIDE NARRATIVE OF THE TESTING AND ADJUSTMENT PROCEDURE FOR THE SYSTEM. B.LANDSCAPE IRRIGATION SYSTEMS I. DESCRIBE THE TYPE OF IRRIGATORS AND CONTROLLER(S) II. PROVIDE NARRATIVE OF THE TESTING AND ADJUSTMENT PROCEDURE FOR THE IRRIGATION SYSTEM, INCLUDING BUT NOT LIMITED TO, PRESSURE TESTS, WATER COVERAGE, AND PROPER CONTROLLER FUNCTION. C.WATER RE-USE SYSTEMS I. DESCRIBE THE TYPE OF GREY WATER OR RECLAIMED/RECYCLED WATER SYSTEM. II. PROVIDE NARRATIVE OF THE TESTING AND ADJUSTMENT PROCEDURE FOR THE SYSTEM (5.410.4.2, 5.410.4.3) 9. A FINAL REPORT FOR THE TESTING AND ADJUSTING OF ALL NEW SYSTEMS SHALL BE COMPLETED AND PROVIDED TO THE FIELD INSPECTOR PRIOR TO FINAL APPROVAL. THIS REPORT SHALL BE SIGNED BY THE INDIVIDUAL RESPONSIBLE FOR PERFORMING THESE SERVICES. (5.410.4.4) 10. AN OPERATION & SYSTEMS MANUAL, SHALL BE PROVIDED TO THE OWNER OR REPRESENTATIVE AND TO THE FIELD INSPECTOR AT THE TIME OF FINAL INSPECTION. (5.410.4.5) 11. IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A MERV OF 13. REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY. (5.504.1) 12. ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, OR SHEET METAL UNTIL THE FINAL START-UP OF THE HEATING, COOLING, AND VENTILATING EQUIPMENT. (5.504.3) 13. ARCHITECTURAL PAINTS AND COATINGS, ADHESIVES, CAULKS, AND SEALANTS SHALL COMPLY WITHT THE VOLATILE ORGANIC COMPOUND (V0C) LIMITS LISTED IN TABLES 5.504.4.1 - 5.504.4.3 (5.504.4.1 - 5.504.4.3). 14. THE VOC CONTENT VERIFICATION CHECKLIST, FORM GRN 2, SHALL BE COMPLETED AND VERIFIED PRIOR TO FINAL INSPECTION APPROVAL. THE MANUFACTURER'S SPECIFICATIONS SHOWING VOC CONTENT FOR ALL APPLICABLE PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD INSPECTOR FOR VERIFICATION. (5.504.4.3.2) 15. MECHANICALLY VENTILATED BUILDINGS SHALL PROVIDE REGULARLY OCCUPIED AREA OF THE BUILDING WITH A MERV 13 FILTER FOR OUTSIDE AND RETURN AIR. FILTERS SHALL BE INSTALLED PRIOR TO OCCUPANCY AND RECOMMENDATIONS FOR MAINTENANCE WITH FILTERS OF THE SAME VALUE SHALL BE INCLUDED IN THE OPERATION AND MAINTENANCE MANUAL. (5.504.5.3) 16. DESIGNATED OUTDOOR SMOKING AREA SHALL BE AT LEAST 25 FEET FROM ANY OUTDOOR AIR INTAKE OR OPERABLE WINDOWS. (5.504.7) 17. THE BUILDING SHALL MEET OR EXCEED THE PROVISIONS FOR MECHANICAL VENTILATION. 18. BUILDINGS THAT USE DEMAND CONTROL VENTILATION SHALL HAVE CO2 SENSORS AND VENTILATION CONTROLS INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE CURRENT EDITION OF THE CALIFORNIA ENERGY CODE, CCR, TITLE 24, PART 6, SECTION 102.1(C)(4) (5.506.2) 19. THE HVAC, REFRIGERATION, AND FIRE SUPPRESSION EQUIPMENT SHALL NOT CONTAIN CFC OR HALONS. (5.508.1) 20. FOR RETAIL FOOD STORES OF 8,000 SQ. FT. OR MORE OF CONDITIONED AREA THAT HAVE A COMMERCIAL REFRIGERATION SYSTEM. (LEAK REDUCTION MEASURES IN ACCORDANCE WITH LAGBC 5.508.2 SHALL APPLY TO REFRIGERATION SYSTEMS WITH A GLOBAL-WARMING POTENTIAL (GWP) OF 150 OR GREATER. SEPARATE MECHANICAL PLAN CHECK IS REQUIRED.) (5.508.2) CAL-GREEN BUILDING NOTES 1.REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF DIFFUSERS AND REGISTERS. CONTRACTOR SHALL VARY LOCATIONS AS REQUIRED TO MATCH FINAL ARCHITECTURAL REFLECTED CEILING PLANS WHEN ISSUED. 2.ALL THERMOSTATS SHALL BE 4'-0'' ABOVE FINISHED FLOOR. 3.DO NOT HANG DUCTS OR PIPES FROM ROOF DECK BUT SUSPEND FROM BEAMS AND BAR JOISTS. PROVIDE CHANNELS AND ANGLE IRON HORIZONTAL SUPPORTS AS REQUIRED AND APPROVED BY THE STRUCTURAL ENGINEER. 4.NO FLEXIBLE DUCT SHALL PENETRATE ANY PARTITION RATED OR OTHERWISE. 5.ALL MATERIAL IN PLENUMS SHALL HAVE A MOLD, HUMIDITY AND EROSION RESISTING FACE THAT HAS MET THE REQUIREMENTS OF U.M.C. STANDARD NO. 6-1 AND A FLAME-SPREAD INDEX NOT GREATER THAN 25 AND A SMOKE DEVELOPED INDEX NOT GREATER THAN 50 WHEN TESTED AS A COMPOSITE PRODUCT PER TEST METHODS LISTED IN CHAPTER 6 OF 2022 CMC. 6.IN ROOM WITH NO CEILING, SUSPEND CEILING DIFFUSERS FROM STRUCTURE ABOVE PER SMACNA GUIDELINES OR LOCAL CODE, WHICHEVER THE MOST RESTRICTIVE. 7.APPLIANCE MUST BE CERTIFIED BY CALIFORNIA ENERGY COMMISSION. 8.EQUIPMENT SHALL BE PROVIDED WITH A PERMANENT LABEL AFFIXED TO THE EQUIPMENT WHICH WILL BE EITHER CLEARLY INDICATE THE ROUTINE MAINTENANCE ACTIONS WHICH MUST BE PERFORMED TO MAINTAIN THE EQUIPMENT IN EFFICIENT OPERATING CONDITION OR INDICATE BY WHICH MAINTENANCE OR OPERATING MANUALS EXPLAIN THE MAINTENANCE REQUIREMENTS IN GREATER DETAIL. 9.DAMPER MANUFACTURER'S LABEL SHALL INDICATE MAXIMUM LEAKAGE OF 3%. 10.THE USE OF THOSE MANUFACTURED DEVICES LISTED IN TABLES 110.2-A THROUGH TABLE 110.2-K IS LIMITED TO ONLY THOSE THAT HAVE BEEN CERTIFIED TO THE CALIFORNIA ENERGY COMMISSION. 11.DUCT SYSTEMS USED WITH BLOWER TYPE EQUIPMENT THAT ARE PORTIONS OF HEATING, COOLING, ABSORPTION, EVAPORATIVE COOLING OR OUTDOOR VENTILATION SYSTEM SHALL BE SIZED IN ACCORDANCE WITH AN APPROVED STANDARD LISTED IN TABLE 1701.1 2022 CMC, OR BY OTHER APPROVED METHODS. 12.ALL AIR DISTRIBUTION SYSTEM DUCTS AND PLENUMS, INCLUDING, BUT NOT LIMITED TO, BUILDING CAVATIES, MECHANICAL CLOSETS, AIR HANDLER BOXES, AND SUPPORT PLATFORMS USED AS DUCTS OR PLENUMS, SHALL BE INSTALLED, SEALED, AND INSULATED TO MEET THE REQUIREMENTS OF CHAPTER 6 OF THE 2022 CMC. LEAKAGE/PRESSURE TESTS SHALL BE COMPLETED BEFORE ANY DUCTWORK INSULATION IS APPLIED. PORTIONS OF SUPPLY-AIR AND RETURN-AIR DUCTS CONVEYING HEATED OR COOLED AIR LOCATED IN ONE OR MORE OF THE FOLLOWING SPACES SHALL BE INSULATED TO A MINIMUM INSTALLED LEVEL OF R-8: a)OUTDOORS; OR b)IN A SPACE BETWEEN THE ROOF AND AN INSULATED CEILING; OR c)IN A SPACE DIRECTLY UNDER A ROOF WITH FIXED VENTS OR OPENINGS TO THE OUTSIDE OR UNCONDITIONED SPACES; OR d)IN AN UNCONDITIONED CRAWLSPACE; OR IN OTHER UNCONDITIONED SPACES. 13.OVERFLOW DRAINS FROM A/C UNITS LOCATED IN AN ATTIC OR FURRED SPACE DISCHARGE AT A POINT WHICH CAN BE READILY OBSERVED. 14.ALL APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE SECURELY FASTENED IN PLACE DESIGNED AND CONSTRUCTED TO SUSTAIN VERTICAL AND HORIZONTAL LOADS WITHIN STRESS LIMITATIONS SPECIFIED IN THE BUILDING CODE. 15.HYDRONIC PIPING INSTALLATION SHALL COMPLY WITH CHAPTER 12 OF THE 2022 CMC. 16.PROVIDE ANY ACCESS DOORS REQUIRED, BUT NOT INDICATED OR SHOWN, ON PLANS, FOR ACCESS TO QUADRANT DAMPERS, FIRE DAMPERS, AND CONTROLS VALVES. 17.CONDENSATE FROM AIR CONDITIONING UNITS SHALL BE ROUTED TO APPROVED PLUMBING RECEPTACLE WITH 1" AIR GAP OR TAILPIECE CONNECTION. IF THESE PLUMBING FIXTURES ARE NOT AVAILABLE, THEN SUBJECT TO FIELD INSPECTION APPROVAL. 18.INSTALL DUCT ACCESSORIES ACCORDING TO APPLICABLE DETAILS IN SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS. INSTALL VOLUME DAMPERS AT POINTS ON SUPPLY, RETURN, AND EXHAUST SYSTEMS WHERE BRANCHES EXTEND FROM LARGER DUCTS. LOCATE VOLUME DAMPERS AT LEAST TWO DIAMETERS FROM A FITTING AND AS FAR AS POSSIBLE FROM OUTLETS. SET DAMPERS TO FULLY OPEN POSITION BEFORE TESTING, ADJUSTING, AND BALANCING. 19.ALL NEW PIPE INSULATION AND DUCT INSULATION SHALL COMPLY WITH UNIFORM MECHANICAL CODE FOR FLAME SPREAD (25) AND SMOKE DISTRIBUTION (50). (SEE SPECIFICATIONS FOR EXACT SIZES) AND CONSISTENT WITH THE LATEST REQUIREMENTS OF THE CALIFORNIA TITLE-24. 20.ALL DUCT DETECTORS SHALL REQUIRE AND ACCEPTANCE FUNCTION TEST. TESTING SHALL BE IN ACCORDANCE WITH NFPA STANDARD 72 AND MANUFACTURER'S INSTRUCTIONS. 21.DUCT DETECTORS SHALL BE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM TO INITIATE SUPERVISION UNLESS OTHERWISE REQUIRED BY THE AUTHORITY HAVING JURISDICTION. 22.ALL CONCEALED SMOKE DETECTORS SHALL BE PROVIDED WITH ACCESS PANELS AND REMOTE LED INDICATORS LOCATED BELOW CEILING TO INDICATE THE LOCATION OF THE SMOKE DETECTOR IT IS SERVING. 23.RELOCATE ANY EXISTING DUCTWORK OR PIPING WHICH IS TO REMAIN BUT INTERFERES WITH THE INSTALLATION OF NEW DUCTWORK AND/OR NEW EQUIPMENT ABOVE CEILING. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS, SERVICES, AND POINTS OF CONNECTION PRIOR TO START OF WORK. 24.PROVIDE ADEQUATE SUPPORTS AND SWAY BRACES FOR ALL PIPING, DUCTWORK, AND EQUIPMENT AS REQUIRED BY CALIFORNIA MECHANICAL CODE. ALL SUSPENDED ELEMENTS TO BE PROVIDED WITH APPROVED LATERAL OR SWAY BRACING. 25.PROVIDE ANY ACCESS DOORS REQUIRED, BUT NOT INDICATED OR SHOWN, ON PLANS, FOR ACCESS TO QUADRANT DAMPERS, FIRE DAMPERS, AND VALVES. 26.JOB CONDITIONS: DUCTWORK, PIPING, AND CONDUIT, AS SHOWN ON DRAWINGS, IS DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY AND SHALL BE FABRICATED AND INSTALLED BASED ON ACTUAL FIELD MEASUREMENT. ADHERE TO DRAWINGS AS CLOSELY AS POSSIBLE IN LAYOUT DUCTWORK. VARY RUN OF PIPING, RUN AND SHAPE OF DUCTWORK AND MAKE OFFSETS DURING PROGRESS OF WORK AS REQUIRED TO MEET STRUCTURAL AND OTHER INTERFERENCES AS APPROVED BY ARCHITECT. INSTALL PIPING AND DUCTWORK IN FURRED SPACES WHEREVER POSSIBLE. RUN EXPOSED PIPING AND DUCTWORK PARALLEL TO, OR AT RIGHT ANGLES TO, BUILDING WALLS. KEEP HORIZONTAL LINES AS CLOSE TO BOTTOM OF STRUCTURES AS POSSIBLE. CONFORM TO CEILING HEIGHTS ESTABLISHED ON ARCHITECTURAL DRAWINGS. COORDINATE WITH OTHER TRADES AS REQUIRED. 27.ALL EQUIPMENTS, DUCTWORK AND PIPING SHALL BE INSTALLED IN TOTAL COMPLIANCE WITH CALIFORNIA MECHANICAL CODE. 28.FILTERS SHALL BE CLASS I OR II FLAMESPREAD, U.L. OR CSFM LISTED. PROVIDE PRE-FILTER WITH A MINIMUM EFFICIENCY OF 90% OR MERV-13. 29.ALL EXISTING DUCT SUPPORTS, PIPE SUPPORTS, ETC. WITHIN THE SCOPE OF WORK SHALL BE BROUGHT UP TO CURRENT CODES. 30.ALL AIR HANDLER DUCT SYSTEM SHALL BE CONSTRUCTED, INSTALLED, AND INSULATED AS PROVIDED IN CHAPTER 6 OF 2022 CMC. 31.MECHANICAL CONTRACTOR SHALL BECOME KNOWLEDGEABLE WITH BUILDING STRUCTURE AND CEILING SPACE. ALLOW FOR INSTALLATION OF EQUIPMENT PRIOR TO BID AND FOR PRICING ADDITIONAL OFFSETS OF DUCTS AND PIPING THAT ARE NOT SHOWN ON DRAWING. 32.FIRE STOPPING REQUIREMENTS: PENETRATIONS THRU RATED WALLS AND FLOORS SHALL BE SEALED WITH A MATERIAL CAPABLE OF PENETRATING THE PASSAGE OF FLAMES AND HOT GASES WHEN SUBJECTED TO THE REQUIREMENTS OF SECTION 07270. PROVIDE U.L. LISTED AND APPROVED FIRE STOP ASSEMBLY AT PENETRATION OF PIPE, CONDUIT AND DUCTWORK THROUGH FIRE RATED WALL. 33.PRIOR TO SUBMISSION OF ANY BID, EACH BIDDER SHALL PERFORM A THOROUGH FIELD SURVEY OF THE EXISTING SITE CONDITIONS AND FEATURES, WHICH WILL BE REQUIRED IN ORDER TO PERFORM THEIR PORTION OF THE CONTRACT. ANY SITE CONDITIONS WHICH MAY RESULT IN AN INSTALLATION ISSUE, THUS RESULTING IN A DEVIATION FROM THE DESIGN DRAWINGS, SHALL BE BROUGHT TO THE ATTENTION OF OWNER AND ARCHITECT/ENGINEER OF RECORD FOR CLARIFICATION PRIOR TO SUBMISSION OF THE CONTRACTOR'S BID. VERIFY DIMENSIONS OF ALL PRODUCTS INCLUDING SPECIFIED EQUIPMENT TO ENSURE PROPER COORDINATION WITH CONSTRUCTION. CONTRACTOR SHALL BEAR ALL COSTS FOR THE RELOCATION OF EQUIPMENT, PIPE, DUCTS, ETC., FOR ANY ERROR THROUGH NEGLIGENCE IN ADVISING OF ANY CONFLICT IN WRITING PRIOR TO SUBMISSION OF ANY BID, AND/OR FROM FAILURE TO PROPERLY COORDINATE INSTALLATIONS OF SYSTEMS. 34.OUTDOOR AIR INTAKES SHALL BE LOCATED 10'-0" FROM EXHAUST OUTLETS OF VENTILATING SYSTEMS, COMBUSTION EQUIPMENT STACKS, MEDICAL SURGICAL VACUUM SYSTEMS, COOLING TOWERS AND AREAS THAT MAY COLLECT VEHICULAR EXHAUST OR OTHER NOXIOUS FUMES. THE BOTTOM OF OUTDOOR AIR INTAKES SHALL BE LOCATED 10'-0" ABOVE THE GROUND LEVEL OR 18" ABOVE THE ROOF LEVEL. 35.EXHAUST OUTLETS SHALL BE LOCATED A MINIMUM 10'-0" ABOVE THE ADJOINING GRADE AND AND 10'-0" FROM DOORS, OCCUPIED AREAS, AND OPERABLE WINDOWS. 36.COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL EQUIPMENT SHALL BE MAINTAINED DURING CONSTRUCTION. 37.ADHESIVES, SEALANTS, AND CAULKS USED ON THE PROJECT SHALL MEET THE REQUIREMENTS OF THE FOLLOWING STANDARDS: 1.ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, SEALANT PRIMERS,AND CAULKS SHALL COMPLY WITH LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY MANAGEMENT DISTRICT RULES WHERE APPLICABLE, OR SCAQMD RULE 1168 VOC LIMITS, AS SHOWN IN TABLES 5.504.4.1 AND 5.504.4.2, CALIFORNIA GREEN BUILDING CODE, 2022 38.PIPES, DUCTS AND CONDUITS SHALL BE SUPPORTED AND BRACED PER THE SMACNA "GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS AND PLUMBING PIPING SYSTEM". DUCTS SHALL BE SUPPORTED AT EACH CHANGE OF DIRECTION AND IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARD - METAL AND FLEXIBLE. 39.PLUMBING PIPE TO BE INSTALLED ABOVE HVAC DUCT IN VARIOUS LOCATIONS AND SHALL BE SUPPORTED AND BRACED PER THE SMACNA "GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS AND PLUMBING PIPING SYSTEM". NO WATER PIPING IS ALLOWED ABOVE THE ELECTRICAL ROOM, TELEPHONE SWITCH ROOM AND DATA/COMMUNICATION ROOM. 40.PROVIDE SMOKE DETECTORS IN MAIN SUPPLY AIR DUCTS OF AIR MOVING SYSTEMS EXCEEDING 2000 CFM PER 2022 CMC SECTION 609.0. 41.AT THE TIME OF ROUGH INSTALLATION, OR DURING STORAGE ON THE CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING, AND VENTILATING EQUIPMENT, ALL DUCTS AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL, OR OTHER ACCEPTABLE METHODS TO REDUCE THE AMOUNT OF DUST, WATER, AND DEBRIS WHICH MAY ENTER THE SYSTEM (2022 CGBC SECTION 5.504.3). 42.IN MECHANICALLY VENTILATED BUILDINGS, REGULARLY OCCUPIED AREAS OF THE BUILDING SHALL BE PROVIDED WITH AIR FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR THAT PROVIDES AT LEAST A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 13. MERV 13 FILTERS SHALL BE INSTALLED PRIOR TO OCCUPANCY, AND RECOMMENDATIONS FOR MAINTENANCE WITH FILTERS OF THE SAME VALUE SHALL BE INCLUDED IN THE OPERATION AND MAINTENANCE MANUAL (2022 CGBC SECTION 5.504.5.3) 43.INSTALLATION OF HVAC, REFRIGERATION, AND FIRE SUPPRESSION EQUIPMENT SHALL COMPLY WITH 2022 CGBC SECTIONS 5.508.1.1 AND 5.508.1.2. HVAC, REFRIGERATION, AND FIRE SUPPRESSION EQUIPMENT SHALL NOT CONTAIN CHLOROFLUOROCARBONS (CFC'S) AND SHALL NOT CONTAIN HALONS (2022 CGBC SECTION 5.508.1). 44.PROVIDE THE BUILDING OWNER OR REPRESENTATIVE WITH DETAILED OPERATING AND MAINTENANCE INSTRUCTIONS AND COPIES OF GUARANTIES/WARRRANTIES FOR EACH SYSTEM. O & M INSTRUCTIONS SHALL BE CONSISTENT WITH OSHA REQUIREMENTS IN CCR, TITLE 8, SECTION 5142, AND OTHER RELATED REGULATIONS. 45.SIZING OF CONDENSATE DRAINS FROM COOLING COILS PER CPC TABLE 814.1 AND SHALL COMPLY WITH THE FOLLOWING CODES: 2022 CMC SECTIONS 310.1, 310.2, 310.3, 310.5, 310.6, 312.0, 1105.7, AND TABLE 310.3 2022 CPC SECTIONS 803.0 TO 807.2 AND 814.0 AIR CONDITIONING CONDENSATE DRAIN LINES FROM EACH HVAC UNIT SHALL BE PIPED FULL SIZE FROM THE UNIT DRAIN OUTLET, WITH "P" TRAP AND PIPED TO NEAREST DRAIN. INSULATE INTERIOR LINES WHERE CONDENSATE CAN OCCUR. 46.DUCT SHALL BE CONSTRUCTED IN ACCORDANCE WITH SMACNA-2006 OR U.L. 181. ALL DUCT DIMENSIONS, AS SHOWN ON MECHANICAL DRAWINGS, ARE CLEAR INSIDE DIMENSIONS. 47.FIRE BLOCKING OR FIRE DAMPER ASSEMBLIES, INCLUDING SLEEVES AND INSTALLATION PROCEDURES AS APPLICABLE WHERE SYSTEM COMPONENTS PENETRATE FIRE RATED SEPARATIONS BLOCKING/DAMPERS SHALL BE RATED IN ACCORDANCE WITH SEPARATION SERVED AND SHALL BE APPROVED BY THE BUILDING INSPECTOR PRIOR TO INSTALLATION. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF FIRE RATED WALLS AND SMOKE SEPARATIONS. 48.ALL HVAC EQUIPMENT AND APPLIANCES SHALL MEET THE REQUIREMENTS OF SECTION 111-113, 115, 120-129 OF THE CALIFORNIA ENERGY EFFICIENCY STANDARDS. 49.ALL HVAC SYSTEMS SHALL MEET THE LATEST CONTROL REQUIREMENTS OF SECTIONS 112 AND 122 OF THE CALIFORNIA ENERGY EFFICIENCY STANDARDS. 50.ALL EQUIPMENT SHALL BE LABELED OR LISTED BY A RECOGNIZED APPROVAL AGENCY. 51.ALL ROOF EQUIPMENT SHALL BE LABELED TO INDICATE THE SPACE IT SERVES WHEN THERE IS MORE THAN ONE HEATING OR COOLING UNIT. 52.WEATHER PROTECTION FOR OPENINGS SHALL BE A MINIMUM OF 26 GAUGE GALVANIZED STEEL (BC 1504) 53.JOINTS, TRAVERSE JOINTS, AND SEAMS FOR DUCT SYSTEMS SHALL COMPLY SMACNA HVAC DUCT STANDARD-METAL AND FLEXIBLE. JOINTS OF DUCT SYSTEMS SHALL BE MADE SUBSTANTIALLY AIRTIGHT BY MEANS OF TAPES, MASTICS, GASKETING, OR OTHER MEANS. CRIMP JOINTS FOR ROUND DUCTS SHALL HAVE A CONTACT LAP OF NOT LESS THAN 1-1/2" AND SHALL BE MECHANICALLY FASTENED BY MEANS OF NOT LESS THAN 3 SHEET-METAL SCREWS EQUALLY SPACED AROUND THE JOINT OR AN EQUIVALENT FASTENING METHOD. 54.ALL MATERIALS EXPOSED WITHIN DUCTS AND PLENUMS INCLUDING ANY ABOVE CEILING RETURN AIR PLENUMS SHALL BE NONCOMBUSTABLE OR SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED TENTY-FIVE (25) AND A SMOKE DEVELOPED INDEX NOT TO EXCEED FIFTY (50) WHEN TESTED AS A COMPOSITE PRODUCT IN ACCORDANCE WITH ASTM E84 OR UL 723 AND SHALL COMPLY WITH ALL REQUIREMENTS OF THE 2022 CMC SECTION 602.2. 55.PORTIONS OF SUPPLY-AIR DUCTS THAT ARE NOT IN ONE OF THESE SPACES, INCLUDING DUCTS BURIED IN CONCRETE SLAB, SHALL BE INSULATED TO TO A MINIMUM INSTALLED LEVEL OF 4.2 (OR ANY HIGHER LEVEL REQUESTED BY CMC SECTION 604.1) OR BE ENCLOSED IN DIRECTLY CONDITIONED SPACE. 56.NEW ROOF TOP EQUIPMENT SHALL BE INSTALLED AT A MINIMUM 10'-0" FROM ROOF EDGE. 57.REFER TO SPECIFICATIONS FOR MATERIALS AND METHODS FOR CONSTRUCTION. WHERE THE WORD "PROVIDE" OR NEW" IS USED SHALL BE UNDERSTOOD TO MEAN "THE CONTRACTOR SHALL FURNISH AND INSTALL". EQUIPMENT AND MATERIALS PROVIDED SHALL BE NEW AND FREE FROM DEFECTS. NO SALVAGED OR REFURBISHED OR USED EQUIPMENT OR MATERIAL WILL BE ACCEPTED. 58.ALL SYMBOLS SHOWN ON SYMBOL LIST ARE NOT NECESSARILY USED ON THIS PROJECT. 59.ARCHITECTURAL AND STRUCTURAL PLANS ARE CONSIDERED PART OF THE DESIGN DRAWINGS AND ARE TO BE USED TO DEFINE DETAIL CONFIGURATIONS INCLUDING, BUT NOT LIMITED TO RELATIVE LOCATION OF MEMBERS, ELEVATION, LOCATION OF ALL OPENINGS, ETC. 57.SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO FABRICATION. MINIMUM ENGINEER REVIEW TIME IS 7 WORKING DAYS BEFORE RETURN TO THE GENERAL CONTRACTOR. SHOP DRAWINGS WILL BE REJECTED FOR INCOMPLETENESS, LACK OF CALCULATIONS (IF REQUIRED) OR CHANGES WITHOUT PRE-APPROVAL. DELAY IN PROCESSING SHOP DRAWINGS WILL BE THE RESPONSIBILITY OF THIS CONTRACTOR. 58.GENERAL AND SUBCONTRACTORS SHALL REVIEW AND STAMP ALL SHOP DRAWINGS PRIOR TO REVIEW BY THE ENGINEER. SHOP DRAWINGS SHALL BE REVIEWED FOR COMPLETENESS AND COMPLIANCE TO THE DRAWINGS. CONTRACTOR SHALL CLEARLY FLAG ANY DEVIATION AND MAKE WRITTEN REQUEST TO THE ENGINEER FOR APPROVAL OF ANY MODIFICATION. ALL MODIFICATIONS MUST BE PRE-APPROVED BEFORE SHOP DRAWINGS ARE PROCESSED & RESUBMITTED FOR FINAL APPROVAL. 59.TIME SPENT BY ENGINEERING PERSONNEL AND STAFF IN REPLY TO REQUESTS FOR INFORMATION, THE ANSWERS FOR WHICH CAN BE FOUND IN THE CONTRACT DOCUMENTS, WILL BE CHARGED TO THE CONTRACTOR AND SUCH REQUEST FOR INFORMATION SHALL BE ACCOMPANIED BY A PURCHASE ORDER FOR THE SERVICE REQUESTED. 60.PROVIDE CODE APPROVED FLEXIBLE CONNECTIONS AT ALL EQUIPMENT. 61.PROVIDE FLASHING AND/OR COUNTER FLASHING OF ALL EXTERIOR PENETRATIONS TO PREVENT WATER INGRESS. 67.INSTALLED AIR CONDITIONER AND HEAT PUMP OUTDOOR CONDENSING UNITS MUST HAVE A CLEARANCE OF AT LEAST 5 FEET FROM THE OUTLET OF ANY DRYER VENT. 70.PROVIDE VIBRATION ISOLATION FOR MECHANICAL EQUIPMENT TO PREVENT TRANSMISSION OF VIBRATION TO BUILDING STRUCTURE AND A VIBRATION FREE INSTALLATION. 73.MISCELLANEOUS STEEL REQUIRED TO ENSURE PROPER INSTALLATION AND AS SHOWN IN DETAILS FOR DUCTWORK AND EQUIPMENT (UNLESS OTHERWISE NOTED) SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. OTHER TRADES SHALL NOT SHARE SUPPORTS. 76.LOCATIONS AND SIZES OF WALL AND ROOF OPENINGS SHALL BE COORDINATED WITH OTHER TRADES INVOLVED. 77.MANDATORY REQUIREMENTS 77.1.DUCTWORK AND PLENUMS TO BE CONSTRUCTED TO SEAL CLASS A. 77.2.CLARIFICATIONS TO SPACES FOR WHICH OCCUPANT SENSOR VENTILATION CONTROL DEVICES ARE REQUIRED. 77.3.DUCT LEAKAGE TESTING IS NOW MANDATORY. 78.A PERFORMANCE TEST SHALL BE CONDUCTED UPON COMPLETION AND BEFORE APPROVAL OF A VENTILATION SYSTEM SERVING COMMERCIAL COOKING APPLIANCES. THE TEST SHALL VERIFY THE EXHAUST AIRFLOW IN ACCORDANCE WITH SECTIONS 508.10.1.2 THRU508.10.1.5 OR THE AIRFLOW RATE STAMPED ON LISTED HOOD. 79.THE PERMIT HOLDER SHALL VERIFY A CAPTURE AND CONTAINMENT PERFORMANCE OF THE HOOD. A FIELD TEST SHALL BE PERFORMED WITH COOKING EQUIPMENT AT NORMAL OPERATING TEMPERATURE AND CAPTURE AND CONTAINMENT SHALL BE VERIFIED THROUGH A VISUAL OBSERVATION OF SMOKE OR STEAM PRODUCED BY SMOKE CANDLES OR PUFFERS. SMOKE BOMBS RAE PROHIBITED FROM USE ON THIS TEST. 80.PRIOR TO USE OR CONCEALMENT A GREASE DUCT LEAKAGE TEST SHALL BE PERFORMED TO VERIFY THE WELDED SEAMS AND JOINTS ARE LIQUID TIGHT. THE TEST SHALL BE A WATER PRESSURE TEST, A LIGHT TEST, OR AN APPROVED EQUIVALENT TEST. THE PERMIT HOLDER SHALL BE RESPONSIBLE FOR PROVIDING THE EQUIPMENT AND FOR PERFORMING THE TEST. HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 AIR-COOLED CONDENSING UNIT SCHEDULE YORK PD240 SYMBOL REMARKSMANUFACTURER & MODEL NO NOTES: NOMINAL TONNAGE 20 238.0 GROSS SENSIBLE - COOLING CAPACITY (MBH) 34.0 ELECTRICAL EER 10.6 VOLT PH HZ OPER WT (LBS) 208 3 60 1,126 SERVES AHU-1 AHR-1 AND ASME CERTIFIED. 2 REFRIGERANT CIRCUITS SINGLE POINT POWER CONNECTION.1. 2. 3. 4. MCA 89.8 110 ELECTRICAL TO PROVIDE SERVICE DISCONNECT5. PROVIDED BY YORK, FIELD INSTALLED PADDLE FLOW SWITCH . FACTORY CERTIFIED START-UP. 1 YEAR PARTS AND LABOR WARRANTY FOR THE WHOLE UNIT. 6. 7. 8. 9. 1, 2, 3, 4, 5, 6, 7, 8, 9 CALIFORNIA CODE CONFORMANCE ASHRAE 90.1 AND UL LISTED. QTY. 2 HEATING CAPACITY (MBH) GROSS SENSIBLE 220.0 - COMPRESSORS RLA (EACH) 30.1 MCC (EACH) 47 LRA (EACH) 225 HP 3/4 OUTDOOR FAN MOTOR QTY. 4 FLA (EACH) 3.0 MAX FUSE SIZE (A) AIR HANDLING UNIT SYMBOL MANUFACTURER & MODEL NO ELECTRICAL FAN HP VOLTS PHASE HERTZ OPER WT (LBS) REMARKS AIR FLOW (CFM) COOLING CAPACITY (BTU/HR) AIR2O CUSTOM AIR HANDLING UNIT 16,000 @ 1.55" ESP 6,42920208360459,360 NOTES: 1, 2, 3, 4, 5, 6, 7, 8, 9,10, 11459,360 COOLING COIL 6/10 TOTAL AREA SERVED SALES FLOOR MCA MOP (A) 154 175 NOMINAL TONNAGE 40 - HEATING CAPACITY (BTU/HR) SENSIBLE INPUT OUTPUT ACCU 1A AHU 1 -DIRECT COIL 5DX-06-60.0-10-78.0-40 ROWS/FPIMODEL NUMBER OUTSIDE AIR (CFM) 3,600 REFRIG CHARGE LBS(R-410A) SYSTEM #1 SYSTEM #2 34.0 SYSTEM DATA NO. REFRIG CIRCUITS SUCTION LINE OD 2 LIQUID LINE OD 5/8" Ø ACCU 1B 1-3/8" Ø IEER 13.5 YORK PD240 20 238.0 -34.010.6 220.0 -34.0 1, 2, 3, 4, 5, 6, 7, 8, 92083601,12689.8 110230.1 47 225 3/4 4 3.0 2 5/8" Ø1-3/8" Ø 1.SERVED BY ACCU-1A AND ACCU-1B. 2.2" FOAM BOARD R13 INSULATION WITH THERMAL BREAK. 3.DOUBLE WALL AHU WITH MERV-13 AIR FILTER. 4.WITH ROOF CURB. 5.SUPPLY DUCT SMOKE DETECTOR. 6.ACCESSIBLE MAGNEHELIC PRESSURE DIFFERENTIAL MONITORS ACROSS MERV-13 AIR FILTERS 7.WITH 25.5 KW ELECTRIC HEATER FOR REHEAT TO CONTROL TEMPERATURE AND RH. SHALL MAINTAIN 72°F AND 50% RH. 8.TXV'S SHALL BE PROVIDED AN INSTALLED BY AHU MANUFACTURER. 9.WITH 208V SINGLE POINT POWER CONNECTION AND SEPARATE 120V POWER FEED FOR LIGHTING AND CONTROLS. 10.CONTROLS CONTRACTOR SHALL SUPPLY AHU MANUFACTURER WITH ALL END DEVICES, CONTROLLERS, AND WIRING DIAGRAMS FOR INSTALLATION AT AHU FACTORY. 11.EQUIPMENT SHALL BE PROVIDED BY US AIR. CONTACT MARGARET LEMOS @ (626) 664-1922. (CFM) O.A.UNIT NO.TONNAGE NOMINAL % EFF. INPUT OUTPUT C.F.M. (IN.) E.S.P. SERVED AREA ELECTRICAL VOLTAGE SENSIBLETOTAL MANUFACTURER & MODEL NO. V / PH / HZ REMARKS ROOFTOP GAS/ELECTRIC UNIT SCHEDULE REMARKS: HP FAN MAX FUSE BREAKER SIZE (AMPS) IEER COOLING CAPACITY (MBH) HEATING CAPACITY (MBH) 7.5 81.086.9 94.5116.7 208 / 3 / 60 35.5 1,3692,000 0.75 102.02,400 1, 2, 3, 4, 5, 7, 8, 9, 10, 112.0 40RTU 1 CAPTIVEAIRE CAS-HVAC1-I.125-18-7.5T TORTILLERIA 18.6 MCA (AMPS) UNIT WT. (LBS.) 93 CURB WT. (LBS.)DESIRED MAX REHEAT CAPACITY (MBH) 42.4 60.0 1.PROVIDE UNIT WITH PRE-ENGINEERED ROOF CURB. 2.PROVIDE UNIT WITH SUPPLY SMOKE DETECTOR AND WIRED FOR UNIT SHUTDOWN. 3.UNIT WITH BOTTOM SUPPLY AND BOTTOM RETURN. 4.PROVIDE 2" MERV 13 FILTER. 6.PROVIDE 0-100% MODULATING ECONOMIZER WITH DRY BULB SENSOR CONTROL, BAROMETRIC RELIEF, AND FAULT DETECTION DIAGNOSTICS. 7.PROVIDE MANUFACTURER'S CERTIFIED START-UP 8.PROVIDE T24 COMPLIANT PROGRAMMABLE THERMOSTAT. 10.WITH MODULATING HOT GAS REHEAT. 11.COORDINATE WITH MANUFACTURER FOR FINAL SELECTION. HOOD NO. MODEL HOOD 1 CAPTIVEAIRE 6024 ND-2 FILTERS TYPE CAPRATE SOLO FILTER TYPE I LENGTH 12'-0" QTY. 9 1 REMARKS REMARKS: SHOWN FOR REFERENCE ONLY. SEE CAPTIVEAIRE DRAWINGS.1 HEIGHT 16" LENGTH 20" HANGING WEIGHT (LBS.) 564 HOOD 2 EXHAUST CFM 2,700 HOOD 3 HOOD SCHEDULE CAPTIVEAIRE 6024 ND-2 CAPRATE SOLO FILTERI10'-0"7 116"20"9851,500 CAPTIVEAIRE 6024 ND-2 I8'-0"5 116"20"5401,080 HOOD 4 I15-4"2,913 DIFFUSER SCHEDULES TYPESYMBOL& MODEL NO. MANUFACTURER DESCRIPTION REMARKS PERFORATED, STEEL, RETURN PANEL SUPPLY RETURN/EXHAUST (FLUSH FACE) PERFORATED, STEEL, SQUARE CEILING DIFFUSER WITH 4-WAY ADJUSTABLE DISCHARGE PATTERN TITUS MODEL PAS, OR EQUAL TITUS MODEL PXP, OR EQUAL (MODULAR CORE) 1. REFER TO SPECIFICATIONS FOR COMPLETE DESCRIPTION OF AIR TERMINALS. A 1. REFER TO SPECIFICATIONS FOR COMPLETE DESCRIPTION OF AIR TERMINALS. B INSULATION SCHEDULE PIPE SIZE NOTES: 1. 2. MANUFACTURE OWENS CORNING OR APPROVED DUCTS (LINED) HVAC SUPPLY HVAC SUPPLY DUCTS (WRAPPED) HVAC RETURN DUCTS (LINED) HVAC RETURN DUCTS (WRAPPED) A.C. CONDENSATE SERVICE EQUAL 3 PCF DENSITY 1 PCF 3 PCF 1 PCF ED-100 FIBERGLASS FIBERGLASS FIBERGLASS DUCT LINER ED-100 BOARD MATERIAL FIBERGLASS DUCT LINER BOARD TYPE - YES NO YES FOIL - - FOIL - - JACKET SERVICE NO YES VAPOR BARRIER ALL -- ALL 2" 1" 2" K=.27 K=.27 K=.23 1" UNLESS OTHERWISE THICKNESS NOTED 1/2" K=.23 K=.21 REMARKS 3. OWENS CORNING OR APPROVED EQUAL ASJSSII FIBERGLASS ALSO INSULATE SUCTION REFRIGERANT LINES. 4.INSULATION SHALL NOT BE LESS THAN REQUIRED TO MEET MOST CURRENT TITLE 24 REQUIREMENTS. SUPPLY DUCTS RUNNING EXTERIOR TO THE BUILDING, THROUGH UNCONDITIONED SPACES AND IN ATTICS WHERE THE DUCTS RUN ABOVE THE ROOF/CEILING INSULATION SHALL BE INSULATED TO A VALUE OF R-8. SUPPLY AND RETURN DUCTS RUNNING IN WALLS TO BE WRAPPED WITH REFLECTIX DUCT WRAP. FLAME SPREAD/SMOKE DEVELOPED RATING SHALL BE 25/50 PER NFPA. RECTANGULAR, STEEL, CEILING OR SIDEWALL, ADJUSTABLE RETURN/EXHAUST (LOUVERED) TITUS MODEL 250, OR EQUAL 1. REFER TO SPECIFICATIONS FOR COMPLETE DESCRIPTION OF AIR TERMINALS. C LOUVERED, STEEL, RETURN GRILLE, 35° DEFLECTION, 3/4" BLADE SPACING SUPPLY (ADJUSTABLE) TITUS MODEL 350RL, OR EQUAL 1. REFER TO SPECIFICATIONS FOR COMPLETE DESCRIPTION OF AIR TERMINALS. D SEE NOTES 1 TO 4 SPLIT SYSTEM HEAT PUMP SCHEDULE REMARKSREFRIG TYPE INDOOR UNIT CFM OPER WEIGHT LBS INDOOR (LBS.) OUTDOOR UNIT EER2 OPER WEIGHT LBS OUTDOOR (LBS.) AREA SERVED SUPPLY FAN VOLTS / PH / HZ ELECTRICAL INDOOR UNIT MCA MOCPESP (IN. WC) INDOOR UNIT MANUFACTURER & MODEL NO. NOMINAL COOLING CAPACITY (BTUH) NOMINAL HEATING CAPACITY (BTUH) NOMINAL CAPACITY (TONS) AMBIENT TEMP. (°F) SEER2 REFRIGERANT PIPING LIQUID GAS OUTDOOR UNIT MANUFACTURER & MODEL NO.BHP HSPF2 MCA MAX. BREAKER (AMPS) ELECTRICAL OUTDOOR UNIT VOLTS/PH/HZ REMARKS: 1.PROVIDE TITLE 24 COMPLIANT WIRED PROGRAMMABLE THERMOSTAT. 2.MOUNT CONDENSING UNIT ON SPRING ISOLATORS. 3.THE INDOOR UNIT SHALL HAVE A BUILT-IN CONDENSATE PUMP. 4.CONTRACTOR TO DETERMINE THE BEST POSSIBLE ROUTING OF ALL REFRIGERANT PIPING AS MEANS & METHODS. 5.INSTALL SPLIT SYSTEM PER MANUFACTURER'S INSTALLATION MANUAL. PROVIDE MANUFACTURER'S REQUIRED CLEARANCES. 6.PROVIDE 2" MERV-13 AIR FILTER. 7.THE OUTDOOR UNIT SHALL SUPPLY POWER TO INDOOR UNIT VIA 14 AWG X 3 POWER WIRE. FC 1 CU 1 1.51.5 BREAK ROOM, SAFE ROOM, CHECK CASHING 535 SEE REMARK# 7--SAMSUNG AC018BNHDCH/AA 0.8208 / 1 / 60 Ø1/4"Ø1/2"0.1820.1 25 77410A12.0SAMSUNG AC018BXADCH/AA 20,00018,00095 18.0 1198.1 1, 2, 3, 4, 5, 6, 7 OSA CFM 115 1, 2, 3, 4, 5, 7, 8, 9, 10, 11RTU 2 KITCHEN 7.5 81.081.7 78.897.2 208 / 3 / 60 35.5 1,3702,000 0.75 101.82,000 1, 2, 3, 4, 5, 7, 8, 9, 10, 112.0 40RTU 3 CAPTIVEAIRE CAS-HVAC1-I.125-18-7.5T BAKERY 18.6 9339.3 60.0 1, 2, 3, 4, 5, 7, 8, 9, 10, 11RTU 4 MEAT SERVICE 13.5 COP 3.3 3.3 7.5 81.086.9 94.5116.7 208 / 3 / 60 35.5 1,3692,000 0.75 102.02,400 2.0 40 CAPTIVEAIRE CAS-HVAC1-I.125-18-7.5T 18.6 9342.4 60.0 7.5 81.081.7 78.897.2 208 / 3 / 60 35.5 1,3702,000 0.75 101.82,000 2.0 40 CAPTIVEAIRE CAS-HVAC1-I.125-18-7.5T 18.6 9339.3 60.0 1 CAPRATE SOLO FILTER CAPTIVEAIRE 6024 ND-2 11 16"20"1,097CAPRATE SOLO FILTER HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 FAN SCHEDULE REMARKS V / PH / HZ FAN MOTOR RPM FANCFMTYPE NEC FLA (IN WC) ESPSYMBOLSERVICE OPER (LBS) WEIGHTMANUFACTURER & MODEL NO. REMARKS: BACKDRAFT DAMPER. FAN INTERLOCKED WITH LIGHT SWITCH. AMCA SEAL & U.L. CERTIFIED.3 2 1 EF 1 AIRFLOW HP EF 2 ENSURE EXHAUST DISCHARGES AT LEAST 10 FEET FROM AIR INTAKES. 4 SAFETY DISCONNECT SWITCH.5 0.5 208 / 1 / 603.21,100GREENHECK GB-130 1,091 77ROOF MOUNTED BELT DRIVE (E) HALL / BACKSTOCKEXHAUST - 1/4 WATTS FOR REFERENCE ONLY SEE CAPTIVEAIRE DRAWINGS.6 3 4 5 EF 3 KEF 1 1.50 208 / 3 / 609.52,700CAPTIVEAIRE DU180HFA 1,257 229ROOF MOUNTED DIRECT DRIVE TYPE 1 HOOD (KITCHEN)EXHAUST 3 3 4 5 6 KEF 2 KEF 3 MOCP 15 - 0.21 115 / 1 / 600.19100GREENHECK SP-A110 950 23WOMEN RESTROOMEXHAUST 18 -CEILING MOUNTED DIRECT DRIVE 15 1 4 WITH MERV-13 AIR FILTER.7 8 - 1.751,500CAPTIVEAIRE DU180HFA 1,239 222ROOF MOUNTED DIRECT DRIVEEXHAUST 1-1/2 - - 1.51,080CAPTIVEAIRE DU85HFA 1,372 132ROOF MOUNTED DIRECT DRIVEEXHAUST 3/4 - - TYPE 1 HOOD (KITCHEN) TYPE 1 HOOD (PIZZA) MCA 0.2 4 - - - 208 / 3 / 606.6 208 / 3 / 602.6 1 1 3 4 5 61 3 4 5 61 COORDINATE WITH MANUFACTURER FOR FINAL SELECTION.8 8 8 9 KEF 4 0.751,500CAPTIVEAIRE DU85HFA 1,166ROOF MOUNTED DIRECT DRIVEEXHAUST 3/4 - - DOUBLE RACK OVEN -8.9 3 4 5 61 8 KEF 5 0.75500CAPTIVEAIRE CASRE11DD 1,441 224ROOF MOUNTED DIRECT DRIVEEXHAUST 1 - - TORTILLA OVEN -208 / 3 / 603.1 3 4 5 61 8 KEF 6 SF 1 0.50 208 / 1 / 603.2850GREENHECK RSF-90 797 191HALL / BACKSTOCKSUPPLY - 1/4 3 515 74 8 3 WITH SPEED CONTROLLER. 11 9 0.21 115 / 1 / 601.8150GREENHECK SP-B150 1,050 15MEN RESTROOMEXHAUST 128 -CEILING MOUNTED DIRECT DRIVE 15 1 42.2 3 115 / 1 / 60 126 9 9 9 9 9 9 9 ROOF MOUNTED BELT DRIVE AIR DOOR (AIR CURTAIN) SCHEDULE REMARKS V / PH / HZHP MOTOR MAX. VOLUME (CFM) SYMBOL SERVICE OPER (LBS) WEIGHT BASIS OF DESIGN MANUFACTURER MODEL NO. REMARKS: 1 INSTALL PER MANUFACTURER'S RECOMMENDATIONS. FLA AD 1 LENGTH (IN.) MAX. VELOCITY (FPM) 1115 / 1 / 6012,760 MARS HV260-1UD-TS OR EQUAL 140HALL/ BACKSTOCK 9.0606,330 1.252,913CAPTIVEAIRE DU180HFA 1,223 258ROOF MOUNTED DIRECT DRIVEEXHAUST 2 - - TYPE 1 HOOD (TORTILLERIA)-208 / 3 / 607.2 3 4 5 61 8 9 AD 2 1110 / 1 / 60-1,340 ENERSHIELD MCS-72 OR EQUAL 58HALL/ BACKSTOCK -72 3,150 WATTS - 600 1110 / 1 / 60-647 ENERSHIELD MCS-36 OR EQUAL 36PRODUCE PREP -36 3,150 300 AD 3 AD 4 1110 / 1 / 60-1,340 ENERSHIELD MCS-72 OR EQUAL 58MEAT PREP -72 3,150 600 AD 5 1110 / 1 / 60-1,340 ENERSHIELD MCS-72 OR EQUAL 58HALL/ BACKSTOCK -72 3,150 600 1110 / 1 / 60-647 ENERSHIELD MCS-36 OR EQUAL 36-36 3,150 300 AD 6 HALL/ BACKSTOCK 1110 / 1 / 60-647 ENERSHIELD MCS-36 OR EQUAL 36-36 3,150 300 AD 7 LA COCINA 1110 / 1 / 60-647 ENERSHIELD MCS-36 OR EQUAL 36-36 3,150 300 AD 8 LA COCINA EF 4 0.23 115 / 1 / 600.46200GREENHECK CSP-A200 825 36INLINE DIRECT DRIVE (N) HALL / BACKSTOCKEXHAUST 137 - 3 4 5150.6 1 9 HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 2024-08-26 2024-08-26 HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 SoloChill Micro Distributed Models: DA091, DA130, DA220 CL CL So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 ---- SoloChill Micro Distributed Models: DA091, DA130, DA220 1.5T7 8 FC 1 A 24x24 430 CFM (TYP. 5) A24x24 250 CFM REFRIGERATION BY OTHERS REFRIGERATION BY OTHERS REFRIGERATION BY OTHERS REFRIGERATION BY OTHERS REFRIGERATION BY OTHERS 1 2 SD 3 T 5 H 4 T 5 H 4 T 5 H 4 T 5 H 4 6 T 9 EF 3 10 EF 2 10 HOOD 111 HOOD 211 HOOD 311 HOOD 411 1222"Ø 2,913 CFM EA 1222"Ø 2,820 CFM EA 1220"Ø 2,000 CFM EA 1218"Ø 1,400 CFM EA 15 15 15 15 1318"Ø 1,500 CFM EA 14 14 14 14KEF-1 22"Ø KEF-2 20"Ø KEF-3 18"Ø KEF-4 18"Ø 1810"Ø 196"Ø 13 12"Ø 500 CFM EA 14KEF-5 12"Ø 14KEF-4 22"Ø 20 RTU-2 20 RTU-1 20 RTU-3 20 RTU-4 21 AD 1 22 D44x44 6,200 CFM RA (TYP. 2) A24x24 615 CFM SA (TYP. 20) C24x110 615 CFM SA (TYP. 6) 54x30 14"Ø 14"Ø 14"Ø 14"Ø 14"Ø 14"Ø 14"Ø 14"Ø 14"Ø 14"Ø 16"Ø 22"Ø 16"Ø 22"Ø 24"Ø 14"Ø 14"Ø 14"Ø 14"Ø 14"Ø 14"Ø 14"Ø 14"Ø 14"Ø 14"Ø 16"Ø 22"Ø 16"Ø 22"Ø 24"Ø 14"Ø14"Ø14"Ø14"Ø14"Ø14"Ø 16"Ø16"Ø 20"Ø 36x30 24"Ø 54x3030"Ø30"Ø A 24x24 500 CFM SA (TYP. 4) B 24x24 850 CFM RA (TYP. 2) A24x24 400 CFM SA (TYP. 5) B24x24 400 CFM RA B24x24 400 CFM RA A 24x24 480 CFM (TYP. 5) B 24x24 400 CFM RA 20"Ø 18"Ø 16"Ø 12"Ø 12"Ø 12"Ø 12"Ø14"Ø 14"Ø 18"Ø A 24x24 270 CFM SA A24x24 260 CFM SA B 24x24 250 CFM RA B24x24 245 CFM RA 8"Ø 6"Ø 10"Ø 10"Ø 10"Ø 10"Ø 14"Ø 10"Ø 12"Ø 12"Ø 12"Ø 12"Ø 22"Ø 18"Ø 22"Ø 22"Ø 20"Ø 18"Ø 10"Ø 12"Ø 16"Ø 18"Ø 20"Ø 22"Ø 10"Ø (TYP.) SD SD SD SD 20"Ø10"Ø 10"Ø10"Ø 10"Ø10"Ø 14"Ø 18"Ø 10"Ø 14 EF-1 16"Ø 1,100 CFM EA 18"x10" TAG WITH 50% FREE AREA REFRIGERATION MACHINERY ROOM ABOVE DAIRY COOLER. SHALL BE FULLY ENCLOSED UT I L I T Y CA B I N E T . SC-24X18X8.62BOX UT I L I T Y CA B I N E T . SC-24X18X8.62BOX Ø1 4 " 12"Ø 16"Ø 20"Ø AD 2 22 AD 322 AD 422 AD 522 AD 622 AD 722 AD 8 22 REFRIGERATION BY OTHERS EF 4 16 18 8"Ø B24x24 200 CFM RA 8"Ø 18"x10" TAG WITH 50% FREE AREA 24 ROOF HATCH 17SF-1 14"Ø A 24x24 850 CFM MUA 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 MECHANICAL FLOOR PLAN SHEET NOTES: REFER TO MECHANICAL LEAD SHEETS FOR LEGENDS, ABBREVIATIONS AND GENERAL NOTES. ENVIRONMENTAL EXHAUST OUTLETS SHALL TERMINATE NO LESS THAN 3 FEET FROM PROPERTY LINE, 3 FEET FROM OPENINGS INTO BUILDING, 10 FEET FROM A FORCED AIR INLET, AND SHALL NOT DISCHARGE ONTO A PUBLIC WALKWAY. CONTRACTOR SHALL VISIT THE SITE, VERIFY SITE CONDITIONS, IDENTIFY ALL OBSTRUCTIONS, EXACT ROUTING OF DUCTWORK SHALL BE CONTRACTORS RESPONSIBILITY. PROVIDE REQUIRED TRANSITIONS DUCT FITTINGS ETC. TO AVOID ANY OBSTRUCTIONS. KEYED NOTES: 1 2 3 4 5 HVAC UNITS SERVING THE SALES AREA SHALL MAINTAIN 72°F AND 50% RH. 54"x30" LINED SUPPLY AIR DUCT UP THRU ROOF. 54"x30" LINED RETURN AIR DUCT UP THRU ROOF. SUPPLY DUCT SMOKE DETECTOR. TITLE 24 COMPLIANT PROGRAMMABLE THERMOSTAT. TITLE 24 COMPLIANT PROGRAMMABLE HUMIDISTAT. 6 FAN COIL UNIT MOUNTED ABOVE CEILING. PROVIDE CEILING ACCESS PANEL. 7 8 CEILING MOUNTED EXHAUST FAN WITH BUILT-IN BACKDRAFT DAMPER. 9 TYPE 1 HOOD. SEE CAPTIVEAIRE DRAWINGS FOR DETAILS. 10 11 GREASE EXHAUST DUCT DOWN AND CONNECT TO HOOD POC.12 13 14 15 16 17 18 19 20 21 22 23 EXHAUST DUCT UP THRU ROOF TO ROOF MOUNTED EXHAUST FAN. DOUBLE WALL GREASE DUCT BY CAPTIVEAIRE. SEE CAPTIVEAIRE DRAWINGS FOR DETAILS. INLINE EXHAUST FAN WITH BUILT-IN BACKDRAFT DAMPER. NOT USED. EXHAUST DUCT UP THRU ROOF WITH ROOF CAP. OSA DUCT UP THRU ROOF. 21"x20" LINED SUPPLY AIR DUCT AND 28"x10" RETURN AIR DUCT UP THRU ROOF TO RTU. CEILING ACCESS PANEL. SIZED PER FAN COIL MANUFACTURER'S RECOMMENDATIONS. LINED RETURN AIR PLENUM WITH 2" THICK MERV-13 AIR FILTER. LINED SUPPLY AIR PLENUM. SIZE TO BE DETERMINED BY CONTRACTOR. 14"x14" DOOR LOUVER WITH 50% FREE AREA. AIR CURTAIN MOUNTED OVER DOOR. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4. 2. 1. 3. MEZZANINE PLAN NOT USED. EXHAUST DUCT DOWN AND CONNECT TO OVEN POC. 24 EXISTING MECHANICAL EQUIPMENT IN THIS AREA TO REMAIN. HOLD- 420 W 17th St3/7/2025 RESERVOIR RACEWAY CO N T R O L PA N E L FRONT REAR RIGHTLEFT FRONT REAR RIGHTLEFT 2ACCU 1B 20-TONS 1,126 LBS. 7KEF 1 229 LBS. W/ CURB 7KEF 2 222 LBS. W/ CURB 7KEF 3 132 LBS. W/ CURB 7KEF 6 126 LBS. W/ CURB 7KEF 5 234 LBS. W/ CURB 7KEF 4 258 LBS. W/ CURB 5RTU 1 1,369 LBS. W/ CURB 5RTU 2 1,369 LBS. W/ CURB 5RTU 3 1,370 LBS. W/ CURB 5 RTU 4 1,370 LBS. W/ CURB 1AHU 1 40-TONS 6,429 LBS. 6 SF 1 191 LBS. 7EF 1 77 LBS. 2CU 1 1.5-TONS 119 LBS. 9 10"Ø 8 (TYP.) 8 (TYP.) 254T-256T 10 6"Ø 1112 AD J A C E N T R O O F 2ACCU 1A 20-TONS 1,126 LBS. REFRIGERATION EQUIPMENT BY OTHERS 3' - 0 " 2' - 0 " 3' - 0 " 20 ' - 5 " RECOMMENDED MINIMUM CLEARANCES (TYP.) 8 (TYP.) 9 8"Ø 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 MECHANICAL ROOF PLAN SHEET NOTES: REFER TO MECHANICAL LEAD SHEETS FOR LEGENDS, ABBREVIATIONS AND GENERAL NOTES. ENVIRONMENTAL EXHAUST OUTLETS SHALL TERMINATE NO LESS THAN 3 FEET FROM PROPERTY LINE, 3 FEET FROM OPENINGS INTO BUILDING, 10 FEET FROM A FORCED AIR INLET, AND SHALL NOT DISCHARGE ONTO A PUBLIC WALKWAY. CONTRACTOR SHALL VISIT THE SITE, VERIFY SITE CONDITIONS, IDENTIFY ALL OBSTRUCTIONS, EXACT ROUTING OF DUCTWORK SHALL BE CONTRACTORS RESPONSIBILITY. PROVIDE REQUIRED TRANSITIONS DUCT FITTINGS ETC. TO AVOID ANY OBSTRUCTIONS. KEYED NOTES: 1 2 3 4 5 AIR HANDLING UNIT MOUNTED ON ROOF. AIR COOLED CONDENSING UNIT MOUNTED ON SPRING ISOLATORS. 70"x36" SUPPLY AIR DUCT DN THRU ROOF. 70"x36" RETURN AIR DUCT DN THRU ROOF. PACKAGED GAS/ELECTRIC AIR CONDITIONING UNIT WITH ROOF CURB. 6 ROOF MOUNTED MAKE-UP AIR UNIT. 7 8 EXHAUST DUCT UP THRU ROOF WITH ROOF CAP.9 10'-0" EXHAUST RADIUS. NO OUTSIDE AIR INTAKES ALLOWED IN THIS AREA. 10 OSA DUCT UP THRU ROOF. ROOF MOUNTED EXHAUST FAN. 2. 1. 3. 11 12 54"x30" LINED SUPPLY AIR DUCT DOWN THRU ROOF. 54"x30" LINED RETURN AIR DUCT DOWN THRU ROOF. APPLIANCES SHALL BE INSTALLED ON A WELL-DRAINED SURFACE ON THE ROOF. 4. HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 WIRING DIAGRAM FOR DH400ACDC 4-WIRE DETECTOR SYSTEM EQUIPPED WITHOUT A CONTROL PANEL DUCT SMOKE DETECTOR DIAGRAM TYPE 1 - KITCHEN EXHAUST HOOD/DUCT Max. VELOCIT Y 2 1 0 0 F P M Min. VELOCIT Y 1 5 0 0 F P M HOOD SHALL OVERHANG COOKING COMBUSTIBLES 18". Min. Min. CLEARANCE FROM SURFACE AT LEAST 6 INCHES ON NOT MORE THAN A 12-FOOT SECTION EACH EXHAUST OUTLET SHALL SERVE SAME BUILDING LOCATED IN THE SAME ROOM HOODS SERVED BY A SINGLE OR ADJOINING ROOM IN HOODS LESS THAN 12" THE SAME STORY OF THE DUCT SYSTEM SHALL BE 4 FEET MAX. FLASHED SOLID. FROM CEILING MUST BE COOKING SURFACE ALL OPEN SIDES. CLEARANCE FROM LINEAL FT. (1 " P E R L I N E A L F T . F O R SLOPE DUCT T O H O O D M I N . 1 / 4 " P E R HOR. DUCTS E X E E D I N G 7 5 F T . I N L E N G T H ) OF HOOD. 18"METAL SHIELD (TYP.) TYP. CANT STRIP NOTES: RAISED VENTED LEVELING CURB 24" MIN. DECK ROOF 40" 1/4"-20 SMS AT 6" O.C. ROOF OPENING D.S. DISCONNECT SWITCH COMBUSTIBLES 3". 1-HR. GYPSUM BOARD LID (BY DIV. 16) MIN. 3" CLEARANCE LISTED GREASE DUCT ASSEMBLY BY CAPTIVEAIRE 3 5/8" 20 GA. STEEL STUD WALL MINIMUM 5' CLEARANCE FROM COMBUSTIBLE PORTIONS OR R UL LISTED CLEANOUT DOORS IN DUCTS MECH EQUIP 3"MIN "B" TRAP "A" SOLDER ALL JOINTS AS REQUIRED, (TYP) VENT OPEN TO ATMOSPHERE UNION (TYP) SPILL CONDENSATE DRAIN TO APPROVED FIXTURE BELOW 2% SLOPE 1. 2. 3. 4. SEE PLAN FOR PIPE SIZES. INTERIOR CONDENSATE DRAINS ABOVE CEILING SHALL BE INSULATED. IF HORIZONTAL RUN IS GREATER THAN 15FT, INSTALL VENT (SAME SIZE AS DRAIN PIPE). CONDENSATE DRAIN CONNECTIONS SHALL OCCUR ABOVE EQUIPMENT FRAMING TO ALLOW FOR PROPER P-TRAP INSTALLATION. NOTES: LINE CLEANOUT, (TYP) 6" M I N DRAIN SIZE AT LEAST SAME SIZE AS NIPPLE CONNECTION SIZE UNIT TYPE 'A''B' DRAW THRU TSPx1.5+2"TSPx0.5+1" BLOW THRU TSPx1.5+2"TSPx1.5+1" TSP=TOTAL STATIC PRESSURE-INCHES CONDENSATE DRAIN TRAP DETAIL SCALE NONE SCALE NONE SCALE NONE SCALE NONE 1/2" THROUGH BOLT W/ WASHER & LOCK NUT AS REQ'D. WOOD MEMBER, ADD BLOCKING AS REQ'D. ANGLE IRON ANGLE IRON TO WOOD 1/2" LAG BOLTS WOOD MEMBER, ADD BLOCKING AS REQ'D. 1-1/8"x 18 GA HANGER STRAP HANGER STRAP CONNECTION TO WOOD 1/2" THROUGH BOLT W/ WASHER & LOCK NUT AS REQ'D. WOOD MEMBER, ADD BLOCKING AS REQ'D. NUT AND BACKNUT 1/2" THREADED HANGER ROD ROD CONNECTION TO WOOD CONNECTION TO STRUCTURAL MEMBER ABOVE SCALE NONE THERMOSTAT/SENSOR MOUNTING HEIGHT MOUNTING HEIGHT OVER OBSTRUCTION 34 ' M A X 24' MAX FINISH FLOOR46 ' M A X ( S I D E A P P R O A C H ) 42 " M I N - 4 8 " M A X T O HI G H E S T O P E R A B L E P A R T . (F R O N T A P P R O A C H ) 54 " M A X ( S I D E A P P R O A C H ) SW I T C H E S & T H E R M O S T A T S 15 " M I N T O B O T T O M (F R O N T A P P R O A C H ) 9" M I N ( S I D E A P P R O A C H ) OU T L E T S 48 " M A X T O T O P (F R O N T A P P R O A C H ) 54 " M A X ( S I D E A P P R O A C H ) TO P O F S W I T C H E S , O U T L E T S & TH E R M O S T A T S 44 ' M A X ( F R O N T A P P R O A C H A T WO R K S T A T I O N ) 7/16" DIA. HOLE (2) PLACES USE 3/8" DIA. LAGBOLT INTO DOUGLAS FIR WOOD, PLAN VIEW VERT (UP): 940 LBSMAX. ALLOW. LOADS: HORIZ: 60O LBS STEEL WASHER & NEOPRENE GROMMET (#6473) 3/8" TAP 3/8" DIA. STABILIZER BOLT NEOPRENE PAD LEVELLING BOLT 3/8" DIA. RIBBED ISOLATOR 2 1 COMP. 4 3 3" PENETRATION, 1-1/2" EDGE DISTANCE & 2-5/8" END DISTANCE. UNIT LEG TYPICAL ACCU MOUNTING DETAIL SCALE NONE 46 2 5 37 2" LINING (TYP.) ROOF JOIST FLEXIBLE CONN.(TYP.) 10" LONG MAXIMUM. SUPPLY AIR DUCT DUCT CONNECTION DETAIL RETURN AIR DUCT SUPPLY DUCT SMOKE DETECTOR SCALE NONE 1 1.EXHAUST TERMINATION-10'-0" MIN. FROM ADJACENT BUILDING, ADJACENT PROPERTY LINE, AIR INTAKES, AND 10'-0" ABOVE ADJOINING GRADE LEVEL. 2.SEE REQUIREMENT FOR MOTORS AND FANS 3.PROTECT OUTDOOR DUCTS AGAINST CORROSION 4.PROVIDE 18" BETWEEN DUCTS AND COMBUSTIBLES OR 3" MIN. FROM PRETESTED COMBUSTIBLES 5.PROVIDE DISCONNECT SWITCH ADJACENT TO AND IN SIGHT FROM EQUIPMENT SERVED. 6.DISCONNECT SWITCH FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR AND WIRED BY ELECTRICAL CONTRACTOR. 7.FIXED FIRE EXTINGUISHING SYSTEM SHALL BE PROVIDED BY THE CONTRACTOR AND INTERCONNECTED TO THE FUEL OR CURRENT SUPPLY SO THAT FUEL OR CURRENT IS AUTOMATICALLY SHUT-OFF TO ALL EQUIPMENT UNDER THE HOOD WHEN THE FIRE EXTINGUISHING SYSTEM IS ACTUATED. 8.GREASE FANS SHALL HAVE A MINIMUM 5'-0" CLEARANCE FROM COMBUSTIBLE PORTIONS OF THE ROOF. 9.TYPE I HOODS AND NON-ENCLOSED GREASE DUCTS SHALL BE INSTALLED WITH CLEARANCE FROM COMBUSTIBLE CONSTRUCTION OF AT LEAST 18 INCHES. THIS MAY BE REDUCED TO 3 INCHES TO LIMITED COMBUSTIBLE MATERIAL AND 0 INCHES FOR NON-COMBUSTIBLE. HOLD- 420 W 17th St3/7/2025 SCALE NONE SCALE NONE SCALE NONE 46 2 5 37 SCALE NONE 1 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 CU - FC - TTHERMOSTAT PROGRAMMABLE DISC 208/230V-1Ø-60HZ LOW VOLTAGE WIRING NUMBER OF WIRES PER MANUFACTURERS RECOMMENDATIONS MOUNTED ON WALL ALL LINE VOLTAGE CONDUIT, WIRING, AND EQUIPMENT SHOWN SOLID SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. LEGEND SPLIT SYSTEM CONTROL DIAGRAM FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL LINE VOLTAGE CONDUIT, WIRING, AND EQUIPMENT SHOWN DASHED SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. EXHAUST ROOF CAP DETAIL ROOFING FIBER CANT FACTORY SUPPLIED ROOF CAP #8 SCREW & WASHER 3/8" LAG SCREW ANCHORED TO WOOD BLOCKING WOOD BLOCKING FACTORY SUPPLIED ROOF CURB FLOOR PLAN FOR SIZE. EXHAUST DUCT. SEE (E) ROOF (E)ROOF JOIST SEE STRUCTURAL SCALE NONE SCALE NONE SCALE NONE 24"x24" RETURN AIR GRILLE WITH ACCESS PANEL ASSEMBLY (UP FLASHING BY MECHANICAL SIGHT GLASS IN LIQUID LINE FILTER/DRYER IN LIQUID LINE CONTRACTOR FOR INSULATION EXPOSED OUTDOORS PROVIDE METAL CLADDING CU - FC - CEILING NON-LOUVERED ACCESS PANEL. SIZE TO MATCH FAN COIL UNITS RETURN AIR PLENUM FILTER FACE AREA SUFFICIENT FOR MAX. SECTIONAL ELEVATION FILTER FC - PLAN FLEXIBLE SUPPLY FLEXIBLE SUPPLY DUCT 250 FT/MIN FACE VEL. DUCTS TO 1000 CFM ONLY) FLEX CONNECTOR SHEET METAL AT SIDES OF FILTER 46"x24.5"1 PANEL SIZEFCU 2 3 OUTSIDE AIR DUCT OUTSIDE AIR DUCT CAN BE CONNECTED IN 3 SIDES. WITH VOLUME DAMPER WITH VOLUME DAMPER 46"x24.5" 46"x24.5" AIR FILTER GAGE NORDICPURE G99 EQUIPMENT PLATFORM WITH NEOPRENE/SPRING ISOLATOR 3/4" COND DRAIN TO APPROVED RECEPTOR CEILING MOUNTED SPLIT HP INSTALLATION DETAIL DUCT HANGER DETAIL REQ'D. PER "SMACNA"- TYPICAL LONGITUDINAL BRACING WHEN TRANSVERSE BRACING AND 3" PROVIDE TRANSVERSE BRACING AT 3O FT. AND LONGITUDINAL BRACING AT 60 FT. WHEN REQUIRED EXCERPT FROM TABLE 5-1 RECTANGULAR DUCT HANGERS MINIMUM SIZE OF SMACNA PER TABLE 7-1 2008 SMACNA SEISMIC RESTRAINT MANUAL, 3RD EDITION. 2005 HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE, 3RD EDITION 1"X 18 GA. 1"X 22 GA. 2. NOTES: 1. MAX. HALF OF P/2 =72 P/2 =30 PERIMETER/IN. DUCT PAIR AT 10 FT SPACING TYPICAL SQUARE OR RECTANGULAR DUCTWORK 1" 3/8" 10 GA. #10 SELF-TAPPING S.M.S. EQUALLY SPACED 12" O.C. MAX. (TYPICAL) TO NOTE #2 BELOW ROUND DUCT TYPICAL MAX. 45° 12" GALVANIZED SHEET DIAGONAL BRACING REFER METAL STRAP OR ROD HANGER (REFER TO SCHEDULE BELOW) WHEN REQ'D BRACING 3/8"Ø MACHINE BOLT GALVANIZED SHEET METAL STRAP OR ROD HANGER (REFER TO SCHEDULE BELOW) STRAP WIRE/ROD 1"X 20 GA. 1"X 22 GA. PAIR AT 8 FT SPACING 1/4" 12 GA. STRAP WIRE/ROD 1"X 22 GA. 1"X 22 GA. PAIR AT 5 FT SPACING 1/4" 12 GA. STRAP WIRE/ROD 1"X 22 GA. 1"X 22 GA. PAIR AT 4 FT SPACING 1/4" 12 GA. STRAP WIRE/ROD 1"X 18 GA.P/2 =96 3/8"1"X 20 GA.1/4"1"X 22 GA.1/4"1"X 22 GA.1/4" SINGLE HANGER MAXIMUM ALLOWABLE LOAD STRAP WIRE OR ROD (DIA.) WHEN STRAPS ARE LAP JOINED USE THESE MAXIMUM FASTENERS 1"X18, 20, 22 GA - TWO #10 OR ONE 1/4" BOLT 1"X16 GA - TWO 1/4" DIA. 1-1/2"X16 GA - TWO 3/8" DIA. PLACE FASTENERS IN SERIES, NOT SIDE BY SIDE. 1"X22 GA - 260 LBS. 1"X20 GA - 320 LBS. 1"X18 GA - 420 LBS. 1"X16 GA - 700 LBS. 0.106" - 80 LBS. 0.135" - 120 LBS. 0.162" - 160 LBS. 1/4" - 270 LBS. 3/8" - 680 LBS. TO NOTE #2 BELOW DIAGONAL BRACING REFER PROVIDE TRANSVERSE BRACING AT 3O FT. AND LONGITUDINAL BRACING AT 60 FT. WHEN EXCERPT FROM TABLE 5-2 MINIMUM HANGER SIZE FOR ROUND DUCT OF SMACNA REQUIRED PER TABLE 7-1 2008 SMACNA SEISMIC RESTRAINT MANUAL, 3RD EDITION. 2005 HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE, 3RD EDITION 2. NOTES: 1. 12 FT. 12 FT. 11" THRU 18" 10" & SMALLER DUCT DIA.MAXIMUM TWO 12 GA. OR ONE 8 GA. ONE 12 GA. 1/4" 1/4" 1"X 22 GA. 1"X 22 GA. 12 FT.19" THRU 24"TWO 10 GA.1/4"1"X 22 GA. SPACING WIRE DIA. ROD STRAP 12 FT.25" THRU 36"TWO 8 GA.3/8"1"X 20 GA. 2 M4.0 2 M4.02 M4.0 2 M4.0 - NOT USED - - NOT USED - - NOT USED - HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 YARD BOXY.B.REMOVE/ABANDON ABOVE INDIRECT REDUCED PRESSURE B.F.P. BACKFLOW PREVENTER IND RP ABV. B.F.P. DRAIN GW D PC/SOC D GW PLUG COCK / SHUT-OFF COCK GREASE WASTE NOT IN PLUMBING CONTRACTN.I.P.C. FD or AD FLOOR OR AREA DRAIN PRESSURE REDUCING VALVE POINT OF CONNECTION P.R.V. P.O.C. REQUIRED VENT THRU ROOF RECTANGULAR POLYVINYLCHLORIDE V.T.R. REQ'D RECT. P.V.C. FCO RD OR OD WCO FLOOR CLEANOUT ROOF OR OVERFLOW DRAIN WALL CLEANOUT FLOOR HEATER INVERT ELEVATION GALLONS PER MINUTE FIXTURE UNIT FINISHED FLOOR I.E. G.P.M. HTR. FLR. F.U. FIN. FLR. STORM DRAIN FLOOR SINK CHECK VALVE SD OD FS CWV CV GV/SOV CWV SD OD COMBINATION WASTE AND VENT GATE VALVE / SHUT OFF VALVE OVERFLOW STORM DRAIN BELOWBEL.HW HOT WATER LINE CONNECT CONCRETE CAST IRON CEILING EXISTING DOWN C.I. DN. CLG. EXIST. CONN. CONC. GAS LINE VENT LINEV G HWR CD DOWNSPOUTDS S or W S or W G DS CD SOIL OR WASTE - SUSPENDED SOIL OR WASTE BELOW FLR OR GRADE HOT WATER RETURN CONDENSATE DRAIN DESCRIPTIONABBREV. CW ABBREV.SYMBOL PLUMBING LEGEND DESCRIPTION COLD WATER LINE (E) NEW(N) PIPE SPECIFICATIONS 3. CONDENSATE DRAINS... 4. WASTE & VENT: GENERAL NOTES 1. SLOPE ALL SOIL & WASTE LINES MIN. 2% (¼" PER FT.) 7. PLUMBING CONTRACTOR SHALL VERIFY LOCATION OF SITE PIPING AND CABLES BEFORE TRENCHING. 11. RECOMPACT ALL PLUMBING EXCAVATION. 13. VERIFY SIZE, LOCATION, DEPTH, ETC., OF ALL UTILITIES IN THE FIELD. 14. ALL FLOOR SINKS UNDER CASES OR EQUIPMENT SHALL BE HALF EXPOSED. 20. NO CLEANOUTS SHALL OCCUR UNDER OR BEHIND ANY CASE OR FIXTURE. 22. ALL LINES TO BE LOCATED AWAY FROM BEARING FOOTING, OR AS DIRECTED BY STRUCTURAL ENGINEER. 27. ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTING AGENCY. 29. BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH SECTIONS 701.0 AND 903.0 OF CPC. SERVICE - WATER NOTES 1.ALL SERVICE HOT WATER PIPE RUNS GREATER THAN 12'-0" SHALL BE INSULATED ACCORDING TO THE REQUIREMENTS SET IN SECTION 609.11.1 AND 609.11.2 OF THE 2022 CPC. 2.PLUMBING FIXTURES SHALL BE CERTIFIED BY THE CALIFORNIA ENERGY COMMISSION. FIXTURE TOTAL PRESS. (PSIG) MAX FLOW RATE SINK FAUCETS 20 - 60 1.8 GPM URINAL 20 - 80 0.125 GPF FILTERED COLD WATERFCWPIPE TEE DOWN PIPE TEE UP PIPE DOWN/FROM BELOW PIPE UP TAG FIXTURE WASTE TRAP VENT COLD WATER WATER HOT REMARKS PLUMBING FIXTURE SCHEDULE TRAP PRIMER - M1FAB M2-500 -1/2"---TP SHEET INDEX SHT.NO.DESCRIPTION P-0.0 PLUMBING GENERAL NOTES, ABBREVIATIONS AND SCHEDULES P-1.0 PLUMBING ADDITIONAL NOTES AND CALCULATIONS P-2.0 PLUMBING FLOOR PLAN - DOMESTIC WATER POINT OF DISCONNECTIONP.O.D. PLUMBING FLOOR PLAN - WASTE & VENT MS 1/2"1/2"2"2" 2"2" 1-1/2" 1-1/2" P-2.2 S2 2"2"1/2"1/2"1-1/2"3-COMPARTMENT SINK - KINTERA MANUFACTURING MODEL KES3C1818S-218S3 24" X 24" ADVANCE TABCO MODEL 9-OP-4. WITH VACUUM BREAKER SPOUT, 3/4 HOSE THREAD 4"INT.2"1-1/2"-WC FLUSH VALVE WATER CLOSET. ADA COMPLIANT BY ARCHITECTS/OWNER L 1-1/2"1/2"2"2"1/2" FS --1-1/2"2"2"INSTALL COMPLETE WITH DOME STRAINER & HALF GRATE. PROVIDE TRAP PRIMER HALF GRATE - 12"W x 12"D x 6"H FLOOR SINK. ZURN Z1910 OR APPROVED EQUAL 1/2"1/2"2"2"1-1/2" FD --1-1/2"2"2"IRON ADJUSTABLE TRACTOR GRATE, SEDIMENT BUCKET PROVIDE TRAP PRIMER8" Ø FLOOR DRAIN. WATTS FD-100-A HS GSW - MODEL HS-1615S-N HAND SINK ASSEMBLY OR APPROVED EQUAL 1/2"1/2"2"2"1-1/2" WITH VACUUM BREAKER (AIR-BREAK BACK FLOW) FAUCET SPOUT, 3/4 HOSE THREAD. ZURN Z841M-XL 1.8 GPM T&S - B-2342 FAUCET 1.5 GPM AERATOR. INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS. T&S - B-0133-A12-V-BC - FAUCET 1.5 GPM AERATOR. INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS. T&S FAUCET MUST HAVE A FLOWRATE OF NO MORE THAN 1.8 GPM. SINK MUST BE PROVIDED WITH WALL BRACKETS. ELECTRONIC TRAP PRIMER - SIOUX CHIEF 695-ES01 -1/2"---TP2 2 COMPARTMENT SINK - BK BKS-2-18-14-18TS OR APPROVED EQUAL WITH SOV & RUN 1/2" TRAP PRIMER LINE TO ALL FLOOR DRAIN AND FLOOR SINK WITH SOV & RUN 1/2" TRAP PRIMER LINE TO ALL FLOOR DRAIN AND FLOOR SINK 6" W. TRENCH DRAIN. ZURN Z890 -2"3"3"TD RUN 1/2" TRAP PRIMER LINE TO TRENCH DRAIN P-TRAP P-3.0 PLUMBING DETAILS - WATER HEATER SYSTEM LAVATORY. SHALL BE ADA COMPLIANT BY ARCHITECTS/OWNER P-2.4 PLUMBING ROOF PLAN P-3.1 PLUMBING DETAILS TAG MAKE & MODEL GPH @ 70°F RISE RECOVERY REMARKS PLUMBING EQUIPMENT SCHEDULE MODEL ST-35-CL AMTROL FACTORY PRECHARGED OF 38 PSIET-1 --3.2 -RCP-1 STORAGE CAP. (GALS.) ELECTRICAL HP V PH HZ WATER TEMP. IN (°F)OUT (°F)WT. (LBS.) SHIPPINGGAS (MBH) INPUT ------40 ----0.167 HP 120 1 --12 INSTALL PER MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS AOSMITHWH-3 658140100-120 1 60 70BTH-150 Mxi 150 553 TACO SERIES 0013 PIPE INSULATION SCHEDULE PIPING SERVICE MATERIALS CONDENSATE DRAIN THICKNESS 3/4" INSULATION SHALL BE ONE-PIECE PREFORMED GLASS FIBER INSULATION WITH INTEGRAL ALL-PURPOSE FIRE RETARDANT, GLASS YARN SCRIM LAMINATED, WHITE JACKET, “K” FACTOR SHALL BE 0.23 MAXIMUM AT 75 DEGREES F. MEAN TEMPERATURE. INSULATION INSULATION SHALL BE ONE-PIECE PREFORMED GLASS FIBER INSULATION WITH INTEGRAL ALL-PURPOSE FIRE RETARDANT, GLASS YARN SCRIM LAMINATED, WHITE JACKET, “K” FACTOR SHALL BE 0.23 MAXIMUM AT 75 DEGREES F. MEAN TEMPERATURE. DOMESTIC HOT WATER SUPPLY & RETURN SIZE PIPE 1"1/2" & 3/4" 1-1/2"1" & 1 1/4" 3/4" FF FILL FAUCET - FISHER MANUFACTURING POT FILLER HOSE STYLE SINGLE WALL MOUNT 3/4"FAUCET MUST HAVE A FLOWRATE OF NO MORE THAN 1.8 GPM. WHA WATER HAMMER ARRESTOR BY PDI OR APPROVED EQUAL 1"WITH ACCESS PANEL. PROVIDED AS SUGGESTED BY PDI. --- --- - - PLUMBING FLOOR PLAN - GAS & CONDENSATEP-2.3AOSMITHWH-4 658140100-120 1 60 70BTH-150 Mxi 150 553 P-3.2 PLUMBING DETAILS DF DRINKING WATER FOUNTAIN ELKAY EZ0TL8WSSK OR APPROVED EQUAL 1/2"SHALL BE MOUNTED AND INSTALLED PER MANUFACTURER'S INSTALLATION AND OPERATING MANUAL---- S1 1/2"1/2"2"2"1-1/2"T&S - 5PR-8W08 FAUCET 1.5 GPM AERATOR. INSTALL P-TRAP AND DIRECT WASTE TO SEWER LINE SINGLE COMPARTMENT SINK KINTERA KES1C1818-L18 - OR APPROVED EQUAL 1.WATER.... TYPE "K" SOFT COPPER TUBING BELOW FLOOR OR GRADE. TYPE "L" HARD DRAWN COPPER TUBING WITH WROUGHT SOLDER JOINT FITTINGS ABOVE FLOOR OR GRADE. 2.GAS..........SCHEDULE 40 BLACK STEEL PIPE WITH BLACK MALLEABLE IRON SCREWED FITTINGS. EXPOSED TO WEATHER SHALL BE GALVANIZED, STEEL PIPE. TYPE "L" HARD DRAWN COPPER TUBING WITH WROUGHT SOLDER JOINT FITTINGS. EMERGENCY EYE WASHEEW 2"INT.2"1-1/2"-UR URINAL ADA COMPLIANT BY ARCHITECTS/OWNER WATER HAMMER ARRESTORWHA KOHLER OR APPROVED EQUAL INSTALL AT ADA COMPLIANT - REFER TO ARCH DWGS. PROVIDE 1-1/4" CW SUPPLY ROUGH IN PER CPC 2022 403.3.1 HB1 WALL HYDRANT - ZURN 1305-VB 3/4"WITH VACUUM BREAKER LOSE KEY STOP & LOCK & VANDAL PROOF SCREWS, NICKLE BRONZE, FINISH, INSTALL @+18" HB2 3/4" HB3 3/4" --- --- --- 3/4" HB4 3/4"WITH LOOSE KEY STOP AND VACUUM BREAKER---- HB5 3/4"3/4" CW W/ WILKINS (MODEL BFP-8F) VACUUM BREAKER W/ LOOSE KEY STOP AND VANDAL PROOF SCREWS = PROVIDED BY G.C.---- WITH THE VACUUM BREAKER, WALL MOUNTED, LESS DOOR WITH VACUUM BREAKER AND VANDAL PROOF SCREWS - HOT & CW HOSE BIBB - KROWNE ROYAL SERIES MODEL 24-503 WALL HYDRANT - ACORN 8146 WALL HYDRANT - ACORN 8126 WALL HYDRANT - ACORN 8126 INSTALL PER INSTALLATION AND OPERATING MANUAL REMARKS/SPECIFICATIONSSYMBOL CONNECTION H.W.C.W. BFP -- PLUMBING EQUIPMENT SCHEDULE PRV -2" BACKFLOW WATER PREVENTER CAST IRON - INSTALL PER MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS 2" BACKFLOW PREVENTER WILKINS 975XL MANUFACTURER MODEL GPM FLOW PSI LOSS PRESS. LOCATION AT METER RP-2 --INSTALL PER MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS 1-1/4" BACKFLOW PREVENTER WILKINS 975XL2 RPBFP FOR EVAP COND.15 8.0 RP-3 --INSTALL PER MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS 3/4" BACKFLOW PREVENTER WILKINS 909 RP SEE SHEET P-3.11510.0 2" PRESSURE REDUCING VALVE WILKINS 500XL 62 7.0 (FIELD VERIFY) INSTALL PER MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS REFER TO SHEET P-3.0 INSTALL PER MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS REFER TO SHEET P-3.0 CO-1 --- CO-2 INSTALL IN WORK AREA FLOORS AND EXTERIOR WALKS WITH EXTRA HEAVY CAST IRON TOP--- CO-3 INSTALL AT ALL TYPE WALL CONSTRUCTION AND FINISHES--- CLEAN OUT - J.R. SMITH 4100 - NB CLEAN OUT - J.R. SMITH 4100 - G CLEAN OUT - J.R. SMITH 4472PC INSTALL IN SALES AREA FLOORS WITH NICKEL-BRONZE TOP- - - 2", 3", OR 4" 2", 3", OR 4" 2", 3", OR 4" SERVICE WEIGHT HUBLESS CAST IRON PIPES AND FITTINGS, WRAPPED WITH 3 MIL. PLASTIC 5. SANITARY SEWER: SERVICE WEIGHT HUBLESS CAST IRON PIPES AND FITTINGS, WRAPPED WITH 3 MIL. PLASTIC 6. SINK DRAINS: TYPE "DWV" COPPER DRAINAGE TUBE WITH WROT SOLDER JOINT FITTINGS ONLY. (ABS AND PVC PIPING PROHIBITED) 7. REFRIGERATION DRAINS: TYPE "M" COPPER DRAINAGE TUBE WITH WROT SOLDER JOINT FITTINGS ONLY. (ABS AND PVC PIPING PROHIBITED) 8. SINK DRAIN VALVES: ROTARY WASTE VALVES WITH LEVER / TWIST HANDLES SHALL BE INSTALLED AT ALL 1, 2, AND 3 COMPARTMENT SINKS, ETC. ONLY. MANUAL SINK DRAIN STOPPERS ARE PROHIBITED. P-2.1 PLUMBING DEMO PLAN ELONGATED TOILET, VITREOUS CHINA WITH OPEN SEAT WHITE,1.28 GPF. ADA COMPLIANT MATERIAL AT ALL UNDER GROUND LOCATIONS ONLY - IN ADDITION ABS OR SCHEDULE 40 CPVC PIPING, SHALL BE INSTALLED BELOW SLAB OR GRADE ONLY, APPROVED BY AUTHORITY HAVING JURISDICTION (AJH) MATERIAL AT ALL UNDER GROUND LOCATIONS ONLY - IN ADDITION ABS OR SCHEDULE 40 CPVC PIPING, SHALL BE INSTALLED BELOW SLAB OR GRADE ONLY, APPROVED BY AUTHORITY HAVING JURISDICTION (AJH) 2"2"1-1/2"2"2"1/2"1/2"1-1/2"3-COMPARTMENT SINK - BK BKS-3-1824-14-18T OR APPROVED EQUALS4 T&S - B-0133-A12-V-BC - FAUCET 1.5 GPM AERATOR. INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS. 2"2"1-1/2"2"2"1/2"1/2"1-1/2"3-COMPARTMENT SINK - JOHN BOOS "3BCS" - 3BCS-184-2D18S5 T&S - B-0133-A12-V-BC - FAUCET 1.5 GPM AERATOR. INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS. 3/4" 33. ADDITIONAL PIPING NOTES: a. ABS AND PVC PIPING EXPOSED TO SUNLIGHT SHALL BE PROTECTED BY WATER-BASED SYNTHETIC LATEX PAINTS. (CPC 906.1). b. SUSPENDED PIPING SHALL BE SUPPORTED AT INTERVALS NOT EXCEED THOSE SHOWN IN TABLE 313. 2022 CPC SEC. 313.3 2.DRAWINGS ARE DIAGRAMATIC. DO NOT SCALE PLUMBING PLANS FOR EXACT HORIZONTAL LOCATION OF PIPE RUNS. 3.SUPPLY ROUGH-IN, INSTALL AND CONNECT PLUMBING FIXTURES AS REQUIRED UNLESS OTHERWISE NOTED. 4.VERIFY & COORDINATE ROUGH-IN AND FIXTURE LOCATIONS WITH ARCHITECTURAL DWGS. PRIOR TO FABRICATION OR INSTALLATION OF MATERIALS AND AGAIN PRIOR TO SLAB POUR. 5.VERIFY ALL ELECTRICAL CHARACTERISTICS WITH ELECTRICAL PLANS PRIOR TO BID OR MATERIAL PURCHASE. 6.WORK SHALL NOT BE COVERED UNTIL IT HAS BEEN INSPECTED, TESTED AND APPROVED BY THE PLUMBING INSPECTOR OR OTHER GOVERNMENTAL AUTHORITIES HAVING JURISDICTION. 8.PROVIDE ACCESS DOORS TO ALL CONCEALED VALVES. VALVES SHALL BE LINE SIZE UNLESS OTHERWISE NOTED. 9.FLUSH VALVES, FAUCETS, STOPS BUBBLERS, ETC., SHALL BE ADJUSTED TO THEIR NORMAL WORKING CONDITIONS. 10.ALL LABOR AND MATERIALS SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE OF THE COMPLETED WORK BY THE ARCHITECT, WITH SERVICE, REPLACEMENT OR REPAIR MADE AT NO EXTRA COST TO THE OWNER OR TENANT. 12.ALL MATERIALS, EQUIPMENT, INSTALLATION, ETC., SHALL CONFORM TO ALL REQUIREMENTS OF ALL APPLICABLE CITY, COUNTY, STATE AND FEDERAL CODES, ORDINANCES & REGULATIONS. P-4.0 PLUMBING RISER DIAGRAM - DOMESTIC WATER P-4.1 PLUMBING RISER DIAGRAM - WASTE & VENT 32.SUSPENDED PIPING SHALL BE SUPPORTED AT INTERVALS NOT TO EXCEED THOSE SHOWN IN TABLE 313.3. 2022 CPC SEC. 313.3. 31.ABS AND PVC PIPING EXPOSED TO SUNLIGHT SHALL BE PROTECTED BY WATER-BASED SYNTHETIC LATEX PAINTS. (CPC 906.1). 30.NO WATER-OPERATED EQUIPMENT OR MECHANISM, OR USE A WATER-TREATING CHEMICAL OR SUBSTANCE, WHERE IT IS FOUND THAT SUCH EQUIPMENT, MECHANISM, CHEMICAL, OR SUBSTANCE CAUSES POLLUTION OR CONTAMINATION OF THE DOMESTIC WATER SUPPLY. SUCH EQUIPMENT OR MECHANISM SHALL BE PERMITTED WHERE EQUIPMENT WITH AN APPROVED BACKFLOW PREVENTION DEVISE OR ASSEMBLY. BACKFLOW PREVENTION DEVICES AND ASSEMBLIES SHALL COMPLY WITH TABLE 603.2, EXCEPT FOR SPECIFIC APPLICATIONS AND PROVISIONS AS STATED IN SECTION 603.5.1 THROUGH SECTION 603.5.21. 28.EACH PLUMBING FIXTURE THAT CONNECTS TO THE SANITARY SEWER SYSTEM SHALL BE PROPERLY TRAPPED AND VENTED IN ACCORDANCE WITH THE 2022 CPC. 26.EACH VENT SHALL RISE VERTICALLY TO A POINT NOT LESS THAN SIX (6) INCHES ABOVE THE FLOOD-LEVEL RIM OF THE FIXTURE SERVED BEFORE OFFSETTING HORIZONTALLY OR BEFORE BEING CONNECTED TO ANY OTHER VENT. 25.WATER PIPE AND FITTINGS SHALL NOT EXCEED 0.25% LEAD CONTENT IN SYSTEMS CONVEYING POTABLE WATER. 24.PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH ALL THE REQUIREMENTS IN SECTION 5.303 IN THE 2022 CALIFORNIA GREEN BUILDING CODE. 23.FLOOR DRAINS OR SIMILAR TRAPS DIRECTLY CONNECTED TO THE DRAINAGE SYSTEM AND SUBJECT TO INFREQUENT USE SHALL BE PROVIDED WITH AN APPROVED AUTOMATIC MEANS OF MAINTAINING THEIR WATER SEALS. 21.ALL PIPING IN FINISHED AREAS SHALL BE CONCEALED WHERE POSSIBLE, AND EXPOSED PIPING SHALL BE RUN AS HIGH AS POSSIBLE AND TIGHT TO WALLS. 19.ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND ORDINANCES, AND SHALL CONFORM TO THE CALIFORNIA PLUMBING CODE, LATEST EDITION. (2022) 18.PLUMBING CONTRACTOR TO SET IN PLACE ALL OWNER FURNISHED EQUIPMENT ON FIXTURE CONNECTION SCHEDULE AS DETAILED OR DIRECTED IN FIELD. 16.REFER TO ARCHITECTURAL & KITCHEN DRAWINGS FOR EXACT LOCATION OF ALL FLOOR SINKS, FLOOR DRAINS, AND WATER REQUIREMENTS. 15.FURNISH AND INSTALL ALL BACKFLOW PROTECTION AS REQUIRED BY STATE AND LOCAL HEALTH DEPT. AND APPLICABLE CODES. EXISTING RHEEM WH-1 4513050-120 1 60 70XG50T12HN38U138 150 EXISTING RHEEM WH-2 4513050-120 1 60 70XG50T12HN38U138 150 EXISTING TO REMAIN - SERVICE TO LIKE NEW CONDITION EXISTING TO REMAIN - SERVICE TO LIKE NEW CONDITION (EXIST.) (EXIST.) P-5.0 CERTIFICATE OF COMPLIANCE EMERGENCY EYE WASHEEW W/ SLOAN #EBF-85 ELECTRONIC BATT. OPERATED FAUCET SET TO MAX. 30 SEC. CYCLE W/ BDT MIXING VALVE #MIX-135-A, C.P. "P" TRAP, SUPPLY AND DRAIN FITTING, AERATOR AND MIFAB MC-51-LP CARRIER INSULATE TRAP AND SUPPLY PER CODE MOUNT AS REQ. EEW EYEWASH STATION - WALL MOUNTED - GUARDIAN G1814 3/4"WALL MOUNTED, STAINLESS STEEL BOWL, 2 SPRAY HEADS2"2"1-1/2"- 2"2"1-1/2"2"2"1/2"1/2"1-1/2"3-COMPARTMENT SINK - KINTERA MANUFACTURING MODEL KES31818S-218S6 T&S - B-0133-A12-V-BC - FAUCET 1.5 GPM AERATOR. INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS. S1.1 1/2"1/2"2"2"1-1/2"T&S - 5PR-8W08 FAUCET 1.5 GPM AERATOR. INSTALL P-TRAP AND DIRECT WASTE TO SEWER LINE SINGLE COMPARTMENT SINK KINTERA KES1C1824S-R18 - OR APPROVED EQUAL 34. THE FLOOR SINK MUST BE EASILY ACCESSIBLE FROM THE WALKWAY WITHOUT HAVING TO CRAWL INTO TIGHT SPACES, UNDER EQUIPMENT, OR MOVE ANY EQUIPMENT TO REACH IT. THE FLOOR SINK CANNOT BE IN WALKWAYS OR IN ANY OTHER LOCATION THAT RENDERS IT A TRIPPING HAZZARD. a. THE TOTAL RUN OF THE DRAIN LINE FROM THE EQUIPMENT TO THE FLOOR SINK CANNOT EXCEED (15)-FEET WITH THE EXCEPTION OF WALK-IN UNIT, WHERE THE DRAIN LINE MAY EXCEED THE REQUIRED (15)-FEET WHEN ADEQUATEDRAIN SLOPE IS PROVIDED. ALL DRAIN LINES MUST HAVE A MINIMUM (1/4)-INCH PER FOOT SLOPE FOR ADEQUATE DRAINAGE, AND BE INSTALLED (1/2)-INCH AWAY FROM WALLS, AND NOT CROSS ANY AISLES, TRAFFIC AREAS, OR DOOR OPENINGS. ADDITIONALLY, ALL DRAIN LINES SHALL BE INSTALLED (6)-INCHES ABOVE FINISHED FLOOR. MOUNTING HARDWARE USED TO ELEVATE DRAIN LINES MUST BE EASILY CLEANABLE. UNISTRUTS, FOR EXAMPLE, ARE NOT CONSIDERED EASILY CLEANABLE AND NOT ACCEPTED. 17.PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL SUPPLIES, STOPS, TRAPS, VALVES, SHOCK-STOPS, REGULATORS AND BACKFLOW PROTECTION PER CODE TO OWNER'S FURNISHED SINKS AND EQUIPMENT. 35. AN EFFORT SHOULD BE MADE TO ENCLOSE ALL PLUMBING, CONDUIT, AND GAS LINES WITHIN WALLS. WHERE THIS IS NOT POSSIBLE, MULTIPE RUNS OR CLUSTERS OF PIPING SHOULD BE FURRED IN, ENCASED IN APPROVED RUNWAY OR OTHER APPROVED SEALED ENCLOSURE. ALL CONDUIT, PLUMBING, ETC., NOT CONCEALED WITHIN WALLS, MUST BE INSTALLED AT LEAST SIX (6) INCHES OFF THE FLOOR AND 1/2" INCH AWAY FROM WALLS. ALL EXPOSED FLEX CONDUIT IS TO BE "SEAL-TIGHT" OR EQUIVALENT. (114257). FIXTURE 3 COMPARTMENT SINK 24" X 24" 3 COMPARTMENT SINK 18" X 18" 2 COMPARTMENT PREP SINK 1 COMPARTMENT PREP SINK RESTROOM SINK DUMP/BAR SINK JANITOR / MOP SINK 287,980 BTU/H TOTAL GALLONS PER HOUR CONSUMPTION 440 HAND SINKS 1 4 3 3 25 14 75 168 1 2 2 1 1 11 2 1 1 1 1 1 14 14 6 6 15 6 28 28 12 6 15 66 GPH REQUIREMENTS AS DETERMINED BY THE HEALTH DEPARTMENT AND MANUFACTURERS DATA SHEETS QTY PER FIXTURE NUMBER OF FIXTURES FIXTURE TOTALS SIZING REQUIREMENTS FOR 'NEW' STORAGE TYPE WATER HEATERS COLD & HOT WATER HOSE REEL 7 1 6 42 TANK TYPE GAS WATER HEATER SIZING FORMULA - TOTAL GPH X (77) DEGREE RISE IN WATER REQUIRED X 8.33 LB (WEIGHT OF A GALLON OF WATER) THEN DIVIDED BY THERMAL EFFICIENCY (0.98% - SEE WATER HEATER SPECS ON SHEET P3.0 = BTU INPUT REQUIRED TO FURNISH HOT WATER NECESSARY FIXTURE 3 COMPARTMENT SINK 18" X 18" 1 COMPARTMENT PREP SINK 63,288 BTU/H TOTAL GALLONS PER HOUR CONSUMPTION 74 HAND SINKS 1 3 14 42 1 2 1 1 14 6 14 6 TANK TYPE GAS WATER HEATER SIZING FORMULA - TOTAL GPH X (77) DEGREE RISE IN WATER REQUIRED X 8.33 LB (WEIGHT OF A GALLON OF WATER) THEN DIVIDED BY THERMAL EFFICIENCY AS SET NATIONALLY BY NSF AT .75 OR 75 PERCENT = BTU INPUT REQUIRED TO FURNISH HOT WATER NECESSARY GPH REQUIREMENTS AS DETERMINED BY THE HEALTH DEPARTMENT AND MANUFACTURERS DATA SHEETS QTY PER FIXTURE NUMBER OF FIXTURES FIXTURE TOTALS SIZING REQUIREMENTS FOR THE 'EXISTING' STORAGE TYPE WATER HEATERS COLD & HOT WATER HOSE REEL 1 1 6 6 2 x 38,000 BTU provided 2 x 150,000 BTU provided HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 A.BALANCING OF THE DOMESTIC HOT WATER SYSTEM: 1. B. G. H. L. J. CALGREEN NOTES A. B. C. D. E. 2. 3.CHECK THAT THERE ARE FLOW AT ALL THE SINKS, SERVICE SINK, ETC.. 4. 5.CHECK THE WATER FLOW AT EACH FIXTURE. IF OKAY THEN THE BALANCE IS COMPLETE. 6. C. D.HOT WATER IS DISTRIBUTED VIA TYPE L HARD COPPER PIPES TO ALL FIXTURES. E.HOT WATER WILL BE PROVIDED AT FIXTURES AT THE FOLLOWING TEMPERATURES: F. K. SEISMIC NOTES 1. 2. A. B. C. D. E. F. 6. 5. 1. DEMOLITION NOTES 2. 3 4. 7. 8. 9. TESTING ON PLUMBING SYSTEMS A.WATER TEST -THE WATER TEST SHALL BE APPLIED TO THE DRAINAGE AND VENT SYSTEMS EITHER IN ITS ENTIRETY OR IN SECTIONS. IF APPLIED TO THE ENTIRE SYSTEM, ALL OPENINGS IN THE PIPING SHALL BE TIGHTLY CLOSED, EXCEPT THE HIGHEST OPENING, AND THE SYSTEM FILLED WITH WATER TO A POINT OF OVERFLOW. IF THE SYSTEM IS TESTED IN SECTIONS, EACH OPENING SHALL BE TIGHTLY PLUGGED EXCEPT THE HIGHEST OPENING OF THE SECTION UNDER TEST, AND EACH SECTION SHALL BE FILLED WITH WATER, BUT NO SECTION SHALL BE TESTED WITH LESS THAN A TEN (10) FOOT (3M) HEAD OF WATER. IN TESTING SUCCESSIVE SECTIONS, AT LEAST THE UPPER TEN (10) FEET (3M) OF THE NEXT PROCEEDING SECTION SHALL BE TESTED, SO THAT NO JOINT OR PIPE IN THE BUILDING (EXCEPT THE UPPERMOST TEN (10) FOOT (3M) OF THE SYSTEM) SHALL HAVE BEEN SUBMITTED TO A TEST OF LESS THEN A TEN.(10) FOOT (3M) HEAD OF WATER. THE WATER SHALL BE KEPT IN THE SYSTEM, OR THE PORTION UNDER TEST, FOR AT EAST FIFTEEN (15) MINUTES BEFORE INSPECTION STARTS. THE SYSTEM SHALL THEN BE TIGHT AT ALL POINTS. B.WATER PIPING – UPON COMPLETION OF A SECTION OR OF THE ENTIRE HOT AND COLD WATER SUPPLY SYSTEM, IT SHALL BE TESTED AND PROVED TIGHT UNDER A WATER PRESSURE NOT LESS THAN THE WORKING PRESSURE IN WHICH IT IS TO BE USED. THE WATER USED FOR TESTS SHALL BE OBTAINED FROM A POTABLE SOURCE OF SUPPLY. A FIFTY (50) POUND PER SQUARE INCH (344.5 KPA) AIR PRESSURE MAY BE SUBSTITUTED FOR THE WATER TEST. IN EITHER METHOD OF TEST, THE PIPING SHALL WITHSTAND THE TEST WITHOUT LEAKING FOR A PERIOD OF NOT LESS THAN FIFTEEN (15) MINUTES. COLD WATER PIPE SIZING (TYPE "L" COPPER PIPE) BASED ON PIPE SIZE 3/4"1"1¼"1½"2"2½"3" 3.6 PSI/100 FT. AND MAX. VELOCITY OF 8 FPS CW FLUSH TANK 6 13 431 7192854185 HW 6 13 245 4062846119 CW FLUSH VALVE 0 0 295 66601382 Subject: WATER CALCULATIONS Job Address: 420 WEST 17TH STREET SANTA ANA, CA 92706 (A)Available Water Pressure: 75.00 PSI (B)Water demand: 1. Domestic 62.00 GPM 2. Misc. GPM (C)Pressure loss thru Existing 1-1/2" Water Meter 5.00 PSI Pressure loss thru 2" BFP, Zurn 975XL3 12.00 PSI Pressure loss thru 2" PRV, Wilkins 500XL 9.00 PSI Pressure loss thru Tank Type Water Heater 1.00 PSI (D)Pressure loss due to height:18 Ft. x .434 7.81 PSI (E)Residual Pressure: 25.00 PSI (G)Total pressure loss from above (Items C thru F): 59.81 PSI (H)Minimum pressure available: 75.00 PSI (I)Total pressure loss (Item G above): 59.81 PSI (J)Pressure available for friction loss (H minus I): 15.19 PSI (K)Developed pipe length: 1. Developed length of run (Main to last fixture): 350.00 Ft. 2. 25% of developed length for fittings 87.50 Ft. 3. Equivalent length (developed length +25%) 437.50 Ft. (L)Friction loss per one hundred (100) feet of pipe: = 100' x (J) 15.19 psi divided by (K) 437.50 ft. = 3.65 PSI/100' 5.28 Domestic Hot Water Recirculation Pump/Supply Sizing B.Multiply this total length by 30 Btu/Ft. for insulated pipe and 60 Btu/Ft. for uninsulated pipe to obtain the approximate heat loss. A.APPROXIMATE TOTAL LENGTH OF ALL HOT WATER SUPPLY AND RETURN PIPING. 1.Total length = 793 Ft. x 30 Btu/Ft. = 23,790 2.Approximate Heat Loss = 23,790 C.Divide the total heat loss by 10,000 to obtain the total pump capacity in GPM. 1.HOT WATER SUPPLY = 430 FT. 2.RETURN PIPING = 363 FT. 3.HOT WATER + RETURN PIPING = 793 FT. 1.Approximate Heat Loss = 23,790 / 10,000 = 2.38 D.Select a circulating pump to provide the total required GPM and obtain the head created at this flow. 1.Taco Pump IL0013 0.167 HP = 28 Ft. Head E.Multiply the head by 100 and divide by the total length of the longest run of the hot water return piping to determine the allowable friction loss per 100 feet of pipe. 1.28 Ft. x 100 = 2,800 2.2,800 / 232 Ft.(longest run hot water return) = 12.07 psi/100' F.Determine the required GPM in each circulating loop and size the hot water return pipe based on this GPM and the allowable friction loss as determined above. ½" HOT WATER PIPE SIZING (TYPE "L" COPPER PIPE) BASED ON PIPE SIZE 3/4"1"1¼"1½"2" 12 PSI/100 FT. AND MAX. VELOCITY OF 5 FT/S HWR 3 8 16 28 46 119 PROPOSED SANITARY WASTE FIXTURE SUMMARY FIXTURE DRAIN F.U.QTY. WASTE SAN F.U. TOTAL COLD WATER CW F.U. CW TOTAL HOT WATER HW F.U. HW TOTAL FIXTURE COUNTS TOTAL LOAD FIXTURE COUNTS 74 DFU 39 CW 9 HW TOTAL LOAD 125 DFU 38 CW (R)3-COMP SINK (INDIRECT)2 2 --2 4 (R)PREP-SINK (INDIRECT)2 2 -- HAND SINK 1 1 1 1 2 4 2 4 (R)FLOOR DRAINS 4 2 2 8 (R)FLOOR SINK 13 2 2 26 FLOOR DRAIN 2 2 2 4 2 GREASE WASTE FIXTURE SUMMARY (R)HAND SINK 4 1 1 4 1 4 1 4 FIXTURE DRAIN F.U.QTY. WASTE SAN F.U. TOTAL COLD WATER CW F.U. CW TOTAL HOT WATER HW F.U. HW TOTAL (R)TRENCH DRAINS 1 3 3 3 1 1 1 1 NEW TOTAL OVERALL BASED ON 2022 CBC - PLUMBING 77 FU = 62.0 GPM 44 FU = 26.0 GPM USE 2" COLD WATER SERVICE USE 1-1/2" HOT WATER SERVICE TOTAL SANITARY = 199 WFU USE 4" SANITARY 199 WFU 77 CW 44 HW 35 HW FAUCET(CW & HW HOSE REELS)1 7 1 77 ICE MAKER 2 TRENCH DRAIN 2 3 3 6 0.5 1 MISTING KIT 1 1 1 THESE DOCUMENTS WERE PREPARED PER AVAILABLE AS-BUILT DOCUMENTS. FIELD VERIFY ALL EXISTING CONDITIONS (SIZE, LOCATION, ETC.) PRIOR TO BEGINNING DEMOLITION. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES BETWEEN CONTRACT DOCUMENTS AND EXISTING CONDITIONS. DEMOLITION OR INTERRUPTION TO EXISTING SERVICES SHALL BE MINIMIZED AND COORDINATED WITH THE OWNER'S REPRESENTATIVE. PATCH AND REPAIR AREAS, PIPING, DUCTWORK, ETC., EXISTING OR NEW, DAMAGED AS A RESULT OF THE DEMOLITION WORK. REPAIR TO MATCH EXISTING CONDITIONS. BEFORE DEMOLITION AND REMOVAL OF DUCTWORK OR PIPING, VERIFY HVAC EQUIPMENT CONNECTED ONLY SERVES THE AREA INCLUDED IN THE CURRENT PHASE OF DEMOLITION. ONCE CONFIRMED, DUCTWORK OR PIPING SHALL BE REMOVED TO THE POINTS INDICATED ON PLANS, UNLESS NOTED OTHERWISE. REMOVE ASSOCIATED HANGERS, SUPPORTS, AND ANCHORS OF DEMOLISHED EQUIPMENT, DUCTWORK OR DEVICES. PROVIDE TEMPORARY OR PERMANENT CAPS FOR EXISTING PIPING. NO PIPING SHALL BE LEFT OPEN ENDED. PROVIDE TEMPORARY OR PERMANENT MECHANICALLY FASTENED SHEET METAL CAPS FOR REMAINING DUCTWORK OPENINGS. SEAL AIRTIGHT PER SMACNA GUIDELINES. REPAIR AND OR REPLACE INSULATION REMOVED OR DAMAGED AS A RESULT OF DEMOLITION. DEMOLISHED MATERIAL SHALL BE PROMPTLY REMOVED FROM PROJECT SITE AND DISPOSED OF IN AN EPA-APPROVED MANNER. EQUIPMENT OR DEVICES IN FAIR CONDITION SHALL BE REVIEWED WITH THE OWNER FOR POSSIBLE SALVAGE PRIOR TO DISPOSAL. NEW PLUMBING FIXTURES AND FITTINGS SHALL NOT EXCEED THE MAXIMUM ALLOWABLE FLOW RATE SPECIFIED IN SECTION 5.303.3. (CALGREEN 5.303.3) ABOVE THE FLOOR ARE APPROXIMATE AS THE REQUIREMENTS IS TO B IN ACCORDANCE WITH ALL APPLICABLE CODES AND MEET WITH THE APPROVAL OF ALL GOVERNING AUTHORITIES. WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 20 GALLONS PER MINUTE AT 80PSI, OR THE SHOWER SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE IN OPERATION AT A TIME. (CALGREEN 5.303.3.3) A FINAL REPORT FOR THE TESTING AND ADJUSTING OF ALL NEW SYSTEMS SHALL BE COMPLETED AND PROVIDED TO THE FIELD INSPECTOR PRIOR TO FINAL APPROVAL. THIS REPORT SHALL BE SIGNED BY THE INDIVIDUAL RESPONSIBLE FOR PERFORMING THESE SERVICES. (CALGREEN 5.410.4.4) FOR ALL NEW EQUIPMENT, AN OPERATION & SYSTEMS MANUAL SHALL BE PROVIDED TO THE OWNER AND THE FIELD INSPECTOR AT THE TIME OF FINAL INSPECTION. (CALGREEN 5.410.4.5) THE HVAC, REFRIGERATION, AND FIRE SUPPRESSION EQUIPMENT SHALL NOT CONTAIN CFC OR HALONS. (CALGREEN 5.508.1) THE ATTACHMENT OF THE FOLLOWING ITEMS SHALL BE DESIGNED TO RESIST THE FORCES PRESCRIBED ABOVE, BUT NEED NOT BE DETAILED ON THE PLANS. ALL EQUIPMENT SHALL BE ANCHORED OR BRACED TO MEET THE HORIZONTAL AND VERTICAL FORCES PRESCRIBED IN 2019 CBC, SECTION 1613 AND ASCE 7-05 SECTIONS 13.3, 13.4 AND 13.6. CONTRACTOR SHALL PROVIDE COMPLETE SEISMIC ANCHORAGE AND BRACING FOR ALL PLUMBING EQUIPMENT AND REQUIRED PIPING. THE CONTRACTOR SHALL SUBMIT THE ANCHORAGE DETAILS AND CALCULATIONS FOR ITEMS NOT SHOWN ON THE DRAWINGS AND FOR ALL SUBSTITUTED EQUIPMENT THAT IS GREATER IN WEIGHT OR VARIES MORE THAN 10% IN LENGTH, HEIGHT OR WIDTH FROM THE APPROVED DETAILS TO THE STRUCTURAL ENGINEER OF RECORD FOR REVIEW (ALLOW 4 WEEK REVIEW PERIOD). FOLLOWING THE REVIEW BY THE STRUCTURAL ENGINEER OF RECORD, THE CONTRACTOR SHALL SUBMIT THE ANCHORAGE DETAILS AND CALCULATIONS TO THE ARCHITECT (THIS SHALL BE DONE AT LEAST 12 WEEKS PRIOR TO THE SCHEDULED EQUIPMENT INSTALLATION). THE CONTRACTOR'S STRUCTURAL ENGINEER SHALL PARTICIPATE IN ALL BACK CHECKING PROCEDURES. EQUIPMENT WEIGHING LESS THAN 200 POUNDS AND SUSPENDED FROM A ROOF, CEILING OR HUNG FROM A WALL. EQUIPMENT WEIGHING LESS THAN 20 POUNDS SUPPORTED BY VIBRATION ISOLATORS. EQUIPMENT WEIGHING LESS THAN 400 POUNDS SUPPORTED DIRECTLY ON A FLOOR OR ROOF. TEMPORARY OR MOVEABLE EQUIPMENT THAT IS NOT HARDWIRED OR PLUMBED TO THE BUILDING. FIXTURE COUNTS TOTAL EXISTING LOAD 57 DFU 40 CW EXIST. 3-COMP SINK (INDIRECT)3 ---2 6 EXIST. PREP-SINK (INDIRECT)2 ---2 4 2 4 EXIST./ RELO. FLOOR DRAINS 4 2 2 8 EXIST./ RELO. FLOOR SINKS 14 2 2 28 2 6 DEMO / EXISTING FIXTURE SUMMARY EXIST. HAND SINK 5 1 1 5 1 5 1 5 FIXTURE DRAIN F.U.QTY. WASTE SAN F.U. TOTAL COLD WATER CW F.U. CW TOTAL HOT WATER HW F.U. HW TOTAL EXIST. TRENCH DRAINS 1 3 3 3 18 HW EXIST. LAVATORY 2 1 1 2 2 4 2 4 EXIST. WATER CLOSET 2 4 4 8 5 10 FIRST HOSE BIBB 2 2.5 5 CALGREEN NOTES FOR TESTING & ADJUSTING OF WATER HEATING SYSTEM EXISTING HOSE BIBB 2 2.5 5 EXIST. ADDT'L HOSE BIBB 3 1 3 EXIST. MOP SINK 1 3 3 3 3 3 3 3 URINAL 2 2 2 4 4 8 4 3-COMP SINK (INDIRECT)4 2 --2 8 FLOOR DRAINS 16 2 2 32 2 TRENCH DRAINS 5 3 3 15 8 PREP-SINK (INDIRECT)1 2 --2 2 2 2 (R) LAVATORY 2 1 1 2 1 2 -- (R) WATER CLOSET 2 4 4 8 5 10START SETTING THE BALANCE VALVES TO THE REQUIREMENTS HIGHLIGHTED FOR EACH RISER. (OR BASED ON THE TOTAL GPM REQUIRED AT ALL OF THE FIXTURES ON EACH RISER). IF THE WATER FLOW IS NOT ADEQUATE THEN RESET THE BALANCE VALVE TO PROVIDE MORE OR LESS FLOW. HOT WATER TEMPERATURE WILL BE MAINTAINED THROUGHOUT THE SYSTEM BY USE OF A RE-CIRCULATING PIPING SYSTEM INCORPORATING A SINGLE IN-LINE CIRCULATING PUMP. THE CIRCULATING HOT WATER PUMP SHALL BE CONTROLLED TO OPERATE ONLY WHEN BUILDING IS OCCUPIED. HOT WATER CIRCULATING PUMP AND PIPING FOR WATER VELOCITY NOT TO EXCEED 5 FEET PER SECOND. PIPES ROUTES WILL BE DESIGNED TO AVOID DEAD-LEG PIPING. HOT WATER RETURN LINES SHALL BE PROVIDED TO THE FURTHEST FIXTURE FOR DOMESTIC HOT WATER SYSTEM. GENERAL HOT WATER OUTLETS: 140F WATER GENERATED AT WATER HEATER TO MIXING VALVE 120F AFTER MIXING VALVE AND 115F AT THE FURTHEST OUTLET FROM WATER HEATER. PERFORM TESTING AND ADJUSTING PROCEDURES IN ACCORDANCE WITH APPLICABLE STANDARDS ON EACH SYSTEM. (CALGREEN 5.410.4.3) AFTER COMPLETION OF TESTING, ADJUSTING AND BALANCING, PROVIDE A FINAL REPORT OF TESTING SIGNED BY THE INDIVIDUAL RESPONSIBLE FOR PERFORMING THESE SERVICES. (CALGREEN 5.410.4.4) PROVIDE THE BUILDING OWNER OR REPRESENTATIVE WITH DETAILED OPERATING AND MAINTENANCE INSTRUCTIONS AND COPIES OF GUARANTEES/WARRANTIES FOR EACH SYSTEM. O & M INSTRUCTIONS SHALL BE CONSISTENT WITH OSHA REQUIREMENTS IN CCR, TITLE 8, SECTION 5142, AND OTHER RELATED REGULATIONS (CALGREEN 5.410.4.5) INCLUDE A COPY OF ALL INSPECTION VERIFICATIONS AND REPORTS REQUIRED BY THE ENFORCING AGENCY. (CALGREEN 5.410.4.5.1) SEE THE PUMPS TO RUN AND CHECK ALL THE FLOW RATES, PRESSURES AND AMPS AT THE REQUIRED OPERATING CONDITION. (SEE THE SCHEDULES) SET THE HOT WATER HEATERS TO THE REQUIRED SET POINTS FOR TEMPERATURE ETC. (SEE THE SCHEDULES) ADDITIONAL HOSE BIBB 3 ADDITIONAL HOT WTR HOSE BIBB 1 1 1 1 3 ESPRESSO MACHINE 1 0.5 0.5 MIXER 3 0.5 1.5 PROOFER 1 0.5 0.5 OVEN 1 0.5 0.5 EMERGENCY EYE WASH 1 11 HAND SINK 8 1 1 8 1 8 1 8 FLOOR SINK 13 2 2 26 FLOOR SINK 24 2 2 48 111 MOP SINK 1 3 3 3 3 3 3 3 2-COMP PREP SINK (INDIRECT)1 2 --2 2 2 2 HOLD- 420 W 17th St3/7/2025 (E) TRENCH WH 1 WH 1 WH 2 EXIST. (E)S3 (D)HS (D)S3 (E)HS DRAIN 2 (E)FS (E)S3 (D)WC (D)WC (D)WL(D)WL (E)FD (D)FS (E)FS (E)FS (E)FS (E)FS (E)FS (E)FS (E)MS (E)FS (E)FS EXISTING 50 GAL. WATER HEATER 1 & 2 - 38,000 BTU/H ABOVE CEILING MEAT RECEIVING RESTROOMS FREEZER PRODUCE PREP. RECEIVING DOCK CHANGING ROOM SoloChill Micro Distributed Models: DA091, DA130, DA220 MEAT COOLER DRY STORAGE SALES AREA MEAT MEAT PREP/ CUTTING AREA SERVICE PREP AREA DAIRY COOLER STORAGE ROOM BEER COOLER BAKERY/ TORTILLERIA CHECK CASHING FLORAL ICE LIQUOR SC A L E SC A L E SC A L E SC A L E CL CL CL CL CL So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 DE L Y So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 CL CL CL CL CL 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 PLUMBING DEMO PLAN 1 2 REMOVE EXISTING CLEAN OUT - AND ALL ASSOCIATED PIPING - CAP PIPING BELOW SLAB - PATCH TO MATCH EXISTING PER CODE AS REQUIRED. PLUMBING CONTRACTOR SHALL FIELD VERIFY CONDITION OF EXISTING WATER HEATER INSTALLED AT THE MEZZANINE LEVEL. CONTRACTOR SHALL COORDINATE WITH THE OWNER IF EXISTING WATER HEATER IS TO BE RE-USED. KEYED NOTES SHEET NOTES IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT THE LOCATIONS FOR ALL MECHANICAL REQUIREMENTS WHICH REQUIRE FLOOR PENETRATIONS DO NOT CONFLICT WITH STRUCTURAL MEMBERS IN THE FLOOR. 1. DAMAGES TO THE STRUCTURE DURING DEMOLITION OF PLUMBING WORK SHALL BE RESTORED BACK TO THE SAME CONDITION AS EXISTING. 2. "VERIFY IN FIELD" OR "EXISTING" MEANS THE CONTRACTOR IS TO CONFIRM THE ITEM SHOWN ON THE DRAWING (I.E. EQUIPMENT, PIPE, ETC.) EXISTS AT THE SITE AND IS IN GOOD WORKING CONDITION. SHOULD THE CONTRACTOR FIND THAT THE EQUIP., PIPE, ETC. IS NOT THE EQUAL TO THAT SHOWN ON THE DRAWING, IT IS TO BE REPLACED, IF THE CONTRACTOR HAS ANY QUESTION WHETHER IT IS EQUAL TO WHAT IS SHOWN ON THE DRAWING, THE CONTRACTOR IS TO CONTACT THE DESIGN ENGINEER AND TENANT'S PROJECT MANAGER FOR APPROVAL. CONTRACTOR IS TO NOTIFY TENANT'S PROJECT MANAGER AND DESIGN ENGINEER IN WRITING OF ALL REPLACEMENT ITEMS PRIOR TO CONSTRUCTION. 3. IT IS REQUIRED THAT THE PLUMBING CONTRACTOR MUST VISIT THE JOBSITE TO FAMILIARIZE HIMSELF WITH MAJOR ITEMS SUCH AS STRUCTURAL ELEMENTS AND OTHER EXISTING JOB CONDITIONS THAT MAY AFFECT HIS WORK. ADDITIONALLY, PLUMBING CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH ITEMS AS WASTE, VENTS, WATER LINES, ETC. 4. 3 GENERAL CONTRACTOR TO FIELD VERIFY EXISTING CONDITION OF PLUMBING PIPING AND INSTALLATION WITHIN THIS AREA TO REMAIN, UNLESS NOTED. SHALL SERVICE TO LIKE NEW CONDITION OR SHALL BE REPLACED AS NECESSARY. TAG MAKE & MODEL REMARKS EXISTING WATER HEATER SCHEDULE ELECTRICAL HP V PH HZ WATER TEMP. IN (°F)OUT (°F)(LBS.) SHPPNG WT.GAS (BTUH) INPUT RHEEM WH-1 13050-120 1 60 70XG50T12HN38U138,000 162 BRADFORD WHITE WH-2 13040-120 1 60 70URG140T6N34,000 130 VERIFY WITH OWNER IF TO BE RE-USED VERIFY WITH OWNER IF TO BE RE-USED EXIST. EXIST. STORAGE CAP. (GALS.) HOLD- 420 W 17th St3/7/2025 CL CL So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 19 S6 10 HS 10 HB2 32 HS HS S3 HB2 32 HB2HS S3 HB2 32 SOV (TYP) S1.1 HS 23 RP 11 WM S3 HS (R)S4 (R)S2 32 10 HS MS 10 WCL 1" CW DOWN 25 3/4" HWR 3/4" HW TBV - THERMOSTATIC BALANCING VALVE (TYP.) 3/4" HWR 3/4" HW 26 BFP 2 6 S5 HS 26 1" CW, 1" HW & 3/4" HWR DOWN BELOW F.F. 1 1/4" CW 20 1 1/2" CW 1 1/2" CW 1-1/4" HWR BEL SLAB 1" CW, 1" HW & 3/4" HWR DOWN BELOW SLAB 3/4" CW UP 21 3/4" CW DN BELOW F.F. 1-1/2" CW 1-1/2" HW 1-1/4" HWR 3/4" CW UP 24 3/4" HWR PROVIDE INSTANTANEOUS WATER HEATER TBV - THERMOSTATIC BALANCING VALVE (TYP.) TBV - THERMOSTATIC BALANCING VALVE (TYP.) TBV - THERMOSTATIC BALANCING VALVE (TYP.) TBV - THERMOSTATIC BALANCING VALVE (TYP.) ~ EXISTING DOMESTIC WATER METER AT SIDEWALK FIELD VERIFY EXACT SIZE EXISTING DOMESTIC WATER SERVICE LINE APPROX. 116' RP 1 1" HW P.C. SHALL INSTALL NEW LEAD-FREE TYPE WILKINS 975XL3 RPBFP 1-1/2" HW 1 1/4" CW 1" HWR 1" HW 1-1/4" CW 1-1/2" HW 2" CW 2" CW2" CW 2" PRV 500XL L WC WATER HAMMER ARRESTOR UR EEW 28 IM1" CW, 1" HW & 3/4" HWR S1 EXISTING 50 GAL. WATER HEATER 1 & 2 - 38,000 BTU/H ABOVE CEILING NEW A.O. SMITH BTH-120 WATER HEATERS 3 & 4 60 GAL. CAP. 120,000 BTU/H (M) BEER COOLER (N) CHECKSTAND (M) PRODUCE COOLER (N) CREMERIA ISLAND (N) BAKERY & KITCHEN FREEZER PRODUCE JUICE BAR CONCOURSE (N) PAN DULCE (N) BAKERY PRODUCE PREP (N) CUSTOMER SERVICE (N) CHECK CASHING (N) BAKERY & KITCHEN COOLER (N)SAFE ROOM GENDER NEUTRAL (N) HALL/ BACKSTOCK (N) LA COCINA (N) BAKERY PREP DINING AREA (E) FREEZER (N) DAIRY COOLER (N) HALL / BACKSTOCK (N) MEAT SERVICE (E) HALL/ BACKSTOCK (N) MEAT COOLER(N) MEAT PREP SALES AREA (M) TORTILLERIA PREP 3/4" CW 2" CW 2" CW 17 PRODUCE MISTING SYSTEM 1" CW 1 P.O.C. 7 7 7 7 7 7 7 7 7 77 TD 5 3/4" CW DOWN W/ SOV 14 2 7 7 2" CW DOWN W/ SOV 27 29 29 31 33 34 BEL SLAB 34 SOV (TYP) RP 11 WM19 29 HS7 1" HW HB4 18 1" HW 1-1/4" CW 7 HB4 HB1 FD TP - 9 1-1/4" CW 2" CW 2" CW HB5 TRAP PRIMER BFP 2 6 2" CW 1" HW 3/4" HWR HB418 HB418 HB4 18 TD 5 1" CW UP TO ROOF HB4 18 3/4" CW UP TO ROOF 1 1/2" CW FF 35 CP 1 ET 1 WH 4 WH 3 WH 2 WH 1 ( EXISTING ) (M) TORTILLERIA PREP HS 7 HS HS S1 7 HS7 HS7 5TD 5FS GENDER NEUTRALUR 1" HWR3/4" CW, 3/4" HW & 3/4" HWR DOWN TBV - THERMOSTATIC BALANCING VALVE (TYP.) TBV - THERMOSTATIC BALANCING VALVE (TYP.) 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 P.O.C. CONNECT NEW COLD WATER LINE TO EXISTING WATER LINE IN APPROXIMATE AREA. FIELD VERIFY EXACT LOCATION AND SIZE. VERIFY CONDITION OF EXISTING WATER METER. FIELD VERIFY EXACT SIZE AND FOR PROPER FUNCTION. 1 2 PROVIDE NEW WATER HEATER AS SCHEDULED. REFER TO DETAIL ON SHEET P-6.0 FOR MORE INFORMATION.3 COLD WATER CONNECTION TO OWNER PROVIDED WATER FILTER SYSTEM. CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD. AND TO MAKE FINAL CONNECTIONS. 4 KEYED NOTES 5 1" WATER STUB-OUT FOR FLAKER ICE MACHINE. WATER FILTER BY OWNER. PROVIDE DOUBLE CHECK VALVE / BACKFLOW PROTECTOR, WILKINS 975XL2 RPBFP. 6 3/4" CW & 3/4" HW CONNECT TO SINK FAUCETS. CONTRACTOR TO INSTALL MIXING VALVE.7 8 3/4" CW & 3/4" HW CONNECT TO MOP SINK. INSTALL SERVICE SINK FAUCET W/ SHORT SPOUT W/ ATMOSPHERIC VACUUM BREAKER. FISHER FAUCET MODEL #2445. 9 10 11 CONTRACTOR TO INSTALL EXPANSION TANK, REFER TO FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. CONTRACTOR TO REFER TO INSTALLATION MANUAL AND FOLLOW LOCAL CODES FOR PROPER MOUNTING. 12 13 14 15 ALL EXISTING PLUMBING FIXTURES WITHIN THE EXISTING RESTROOM TO REMAIN. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITION AND DO PROPER MAINTENANCE TO ALL EXISTING FIXTURES. CONTRACTOR TO PROVIDE ALTERNATE COST TO ADD TRAP PRIMER TO FLOOR DRAINS, SINKS, AND TRENCH DRAINS, THAT ARE SUBJECT TO INFREQUENT USE. SHALL FOLLOW LOCAL CODES IF TRAP PRIMER SHALL BE INSTALLED DURING CONSTRUCTION FOR THE FIELD INSPECTOR'S APPROVAL. 16 17 1" HOT AND COLD WATER DROP IN WALL WITH SHUT OFF VALVE & ACCESS PANEL. 3/4" COLD WATER DROP IN WALL WITH SHUT OFF VALVE & ACCESS PANEL. 18 19 20 21 PROVIDE WATER STUB-OUT FOR PROOFER BOX. 1/2" CW W/ SOV AND WATTS 909 RP. 30-60 PSI SHALL BE PROVIDED. IF THE WATER PRESSUR EXCEEDS 60 PSI, AN APPROVED TYPE AND LINE SIZE PRV SHALL BE PROVIDED. 3/4" C.W. UP FROM BEL. SLAB - CONNECT TO UP TO STEAM TABLE FAUCET WITH S.O.V. AND AN APPROVED TYPE B.F.P. CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY EXACT PIPE ROUTING. SHALL INSTALL AN OVER THE RIM FILL PIPE WITH A ONE INCH AIR GAP. PROVIDE COLD WATER UP AND PROVIDE STUB-OUT FOR BEVERAGE STATION. CONTRACTOR TO INSTALL A WATER FILTER SYSTEM. SHALL REFER TO MANUFACTURER'S INSTALLATION AND OPERATING MANUAL. 22 3/4" CW W/ SOV AND WATTS 909 RP TO DOUBLE RACK OVEN. PROVIDE FULL LINE SIZE QUICK DISCONNECT COUPLER.23 3/4" CW. UP FROM BEL. SLAB - CONNECT TO ITEM WITH S.O.V. & APPROVED TYPE B.F.P.24 6" TRENCH DRAIN. CONTRACTOR TO INSTALL A TRAP PRIMER AT THE P-TRAP OF TRENCH DRAIN DISCHARGE. PROVIDE TRAP PRIMER WITH 1/2" COLD WATER. CONTRACTOR TO LOCATE TRAP PRIMER, IN SERVICEABLE LOCATION. SEE DETAIL 10 / P400 REFER TO SHEET P-3.0 WATER HEATER DETAIL FOR ADDITIONAL INFORMATION. 1/2" ICW & RCW 1/2" ICW TO MIST SYSTEM W/ S.O.V. - EXTEND 1/2" RCW TIGHT TO WALL @ +/-6" A.F.F. TO QUICK DISCONNECT COUPLERS (3 PLACES) PROVIDE WATER METER AND BACKFLOW PREVENTER, REDUCED PRESSURE PRINCIPLE BACKFLOW WILKINS 975XL2, CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY EXACT LOCATION AND SHALL REFER TO MANUFACTURER'S INSTALLATION AND OPERATING MANUAL 3/4" CW & HW FOR DUAL TEMP HOSE BIBB, ACORN 8146, WALL MOUNTED, LESS DOOR WITH VACUUM BREAKER AND VANDAL PROOF SCREWS. SHALL ALSO PROVIDE BACKFLOW RP-3. CONTRACTOR TO INSTALL CIRCULATING PUMP, REFER TO FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. CONTRACTOR TO REFER TO INSTALLATION MANUAL AND FOLLOW LOCAL CODES FOR PROPER MOUNTING. 1-1/4" COLD WATER DROP IN WALL WITH SHUT OFF VALVE & ACCESS PANEL - PROVIDE FILL FAUCET WITH VACUUM BREAKER FOR CORN COOKING TANKS. 25 26 27 1" HOT AND COLD WATER FROM BELOW SLAB, PROVIDE WITH SHUT OFF VALVE & ACCESS PANEL. 2" COLD WATER DROP IN WALL WITH SHUT OFF VALVE & ACCESS PANEL. 28 29 3/4" CW & HW FOR MIXER CONNECTION, CONNECT VIA WATTS (MODEL 009QT) BFP 30 3/4" CW FOR MESA GRINDER, CONNECT VIA WATTS (MODEL 009QT) BFP 31 CONTRACTOR TO CONNECT CW SUPPLY W/ SOV & WATTS 909 RP TO THE ICE MAKER, CAPPUCCINO MACHINE, COFFEE MAKER, BEVERAGE DISPENSER. 32 PIPE MATERIAL NOTES COPPER PIPE SHALL BE USED FOR ALL WATER PIPING EXCEPT FILTERED AND R.O. WATER PIPING. TYPE ”L" HARD DRAWN COPPER SHALL BE USED FOR PIPE NOT SET UNDER CONCRETE. TYPE ”K” SOFT COPPER SHALL BE USED FOR PIPING UNDER CONCRETE. FITTINGS SHALL BE WROUGHT COPPER THROUGHOUT. PEX PIPE SHALL BE USED FOR ALL FILTERED AND R.O. WATER LINES, ’’UPONOR” PEX PIPE AND FITTINGS ASTM F 876/877 AND PEX-A FITTINGS ASTM F1960, MULTI-PORT TEES, MANIFOLDS AND TRANSITION FITTINGS AS REQUIRED INSTALLATION SHALL BE AS PER MANUFACTURER’S INSTALLATION INSTRUCTIONS. SHEET NOTES ALL PLUMBING ROUGH-IN WORK AND FINAL CONNECTIONS TO ALL FOOD SERVICE AND RELATED EQUIPMENT AS SHOWN ON THE KITCHEN EQUIPMENT CONTRACTOR'S PLANS TO BE PERFORMED BY THE CONTRACTOR PER NATIONAL AND LOCAL CODES. 1. THE PLUMBING CONNECTIONS, SPECIFICATIONS AND DIMENSIONS SHOWN ON THESE PLANS ARE FOR FOOD SERVICE EQUIPMENT ONLY. SEE ARCHITECT'S PLAN SET FOR ALL OTHER PLUMBING REQUIREMENTS FOR THIS PROJECT. 5. UNLESS OTHERWISE SPECIFIED IN THESE PLANS OR OTHER WRITTEN CONTRACTS, IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO PROVIDE ALL PLUMBING-TYPE MATERIALS INCLUDING VALVES, TRAPS, LINE STRAINERS, FLOOR SINK COVERS, PRESSURE REGULATORS, SIPHON BREAKERS, ETC. 2. PLUMBER SHALL FURNISH AND INSTALL PRESSURE REDUCING VALVE(S) AT DISHWASHER(S), GLASS WASHER(S), STREAMER(S) AND OTHER EQUIPMENT, AS REQUIRED. 3. IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL WATER HEATERS FOR THIS PROJECT AND TO ENSURE ADEQUATE WATER SUPPLY FOR THE FOOD SERVICE EQUIPMENT. WATER TEMPERATURE TO DISHWASHER SHALL BE 120°F. COORDINATE EXACT LOCATION OF WATER HEATER IN FIELD. 4. ALL PLUMBING INSTALLATION IS NEW UNLESS NOTED AS (E) EXISTING.6. CONTRACTOR TO PROVIDE SHUT OFF VALVES TO ALL PLUMBING FIXTURES' WATER CONNECTIONS.7. SHOWN DIMENSIONS FOR ALL FLOOR SINK AND FLOOR DRAIN IS FOR REFERENCE ONLY. CONTRACTOR SHALL FIELD VERIFY THE EXACT LOCATION. SHALL REFER TO REFRIGERATION SHEET R2.0 FOR OTHER FLOOR SINK AND FLOOR DRAIN DIMENSIONS / DISTANCE MEASUREMENTS. 8. CONTRACTOR SHALL INSTALL MIXING VALVES TO ALL LAVATORY AND HAND SINKS.9. 11/8"=1'-0"' SCALE(N) MEZZANINE PLAN PLUMBING FLOOR PLAN - DOMESTIC WATER 3/4" COLD WATER DROP IN WALL WITH SHUT OFF VALVE & ACCESS PANEL. STUB-OUT FOR EYE WASH. 33 HOSE REEL - 3/4" CW & HW TO HOSE REEL CONNECTION. KROWNE MODEL 24-503. SHALL BE PROVIDED W/ S.O.V. PROVIDE AND INSTALL INSTANTANEOUS WATER HEATER, CHRONOMITE SR-20 TYPE. SHALL BE INSTALLED PER MANUFACTURER'S INSTALLATION AND OPERATING MANUAL. 34 WATER PIPING INSTALLED WITHIN A BUILDING AND IN OR UNDER A CONCRETE FLOOR SLAB RESTING ON THE GROUND SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING REQUIREMENTS: (1)FERROUS PIPING SHALL HAVE A PROTECTIVE COATING OF AN APPROVED TYPE; MACHINE APPLIED AND IN ACCORDANE WITH RECOGNIZED STANDARDS. FIELD WRAPPING SHALL PROVIDE EQUIVALENT PROTECTION AND SHALL BE RESTRICTED TO THOSE SHORT SECTIONS AND FITTINGS NECESSARILY STRIPPED FOR THREADING. ZINC COATING (GALVANIZING) SHALL NOT BE DEEMED ADEQUATE PROTECTION FOR PIPING OF FITTINGS. APPROVED NONFERROUS PIPING SHALL NOT BE REQUIRED TO BE WRAPPED. (2)COPPER OR COPPER ALLOY TUBING SHALL BE INSTALLED WITHOUT JOINTS WHERE POSSIBLE. WHERE JOINTS ARE PERMITTED, THEY SHALL BE BRAZED, AND FITTINGS SHALL BE WROUGHT COPPER. ADDITIONAL PIPING NOTES: a. ABS AND PVC PIPING EXPOSED TO SUNLIGHT SHALL BE PROTECTED BY WATER-BASED SYNTHETIC LATEX PAINTS. (CPC 906.1). b. SUSPENDED PIPING SHALL BE SUPPORTED AT INTERVALS NOT EXCEED THOSE SHOWN IN TABLE 313. 2022 CPC SEC. 313.3 10. 35 PROVIDE FILTERED WATER CONNECTION FOR THE STOCK POT FILL FAUCET. AN EFFORT SHOULD BE MADE TO ENCLOSE ALL PLUMBING, CONDUIT, AND GAS LINES WITHIN WALLS. WHERE THIS IS NOT POSSIBLE, MULTIPE RUNS OR CLUSTERS OF PIPING SHOULD BE FURRED IN, ENCASED IN APPROVED RUNWAY OR OTHER APPROVED SEALED ENCLOSURE. ALL CONDUIT, PLUMBING, ETC., NOT CONCEALED WITHIN WALLS, MUST BE INSTALLED AT LEAST SIX (6) INCHES OFF THE FLOOR AND 1/2" INCH AWAY FROM WALLS. ALL EXPOSED FLEX CONDUIT IS TO BE "SEAL-TIGHT" OR EQUIVALENT. (114257). 11. SEPARATE WATER HEATER SYSTEM TO RE-USE THE EXISTING WATER HEATER INSTALLED HOLD- 420 W 17th St3/7/2025 CL CL So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 2" V. UP 7 2" V. S3 HS 2" V. UP 7 FD2 S3 2" V. UP 7 FS2 (E)S5 HS 4" GW S=2% FS FS2 FS FS FS FS FS FS FS FS FS FS FS FS FS FS FS FS WC S6 FS2 HS FS2 S3 HS FS2 HS 4" GW S=2% 4" CO-2 STARTING I.E. = -1'-0" HS 4" CWV S=2% STARTING CLEAN-OUT STARTING I.E. = -1'-0" 7 FS FS 2" V. UP OFFSET TO 2" VTR 3" CWV S=2% 2" V. UP OFFSET TO 2" VTR FS2 2" V. UP 7 4" SS S=2% CO-3 4" SS S=2% S= 2 % 4" CO 3" V. UP OFFSET TO 3" VTR 3" 4" CWV S=2% 2" V. CO-2 FD2 2" V. 2" V. 2" V. UP7 4" SS. S=2% 2" V. UP 7 2" V. UP 7 2" V. UP 7 2" V. UP 7 2" V. UP 7 2" V. UP 7 3" SS S=2% 15 3" V . 3"V. 2" SS S=2% 2" V. UP 7 4" GW S=2% FD2 3" V. UP OFFSET TO 3" VTR 15 3" V. UP OFFSET TO 3" VTR 2" VTR CLEAN-OUT STARTING I.E. = -1'-0" FD2 FD2 3" VTR 2" V. UP OFFSET TO 2" VTR 2" VTR 3" VTR. 3" VTR. TD 2" V. UP OFFSET TO 2" VTR 4" CO-2 4" CO 3"V. 4" SSS=2% 3" 3" S2 FD2 HS 4" CO-1 INV. = -18" FD2 TD2 FD22" V. UP 7 FD2 FD2 2" V. UP 7 2" V. 2" V. HS FD2 S1.1 FD2 FD2 FD2 FD2 FD2 4" CO L L UR WC CO-3 CO-3 FD FS2 HS 4" CLEAN-OUT STARTING I.E. = -1'-0" FD2 4" CO-2 4" CO-2 CO-2 FS 4" CO TD 2" V. UP 7 MS(E)S2 TD TD FD2 FD2 4" CO-2 TD S= 1 % 3"V. 3" V. UP OFFSET TO 3" VTR 3" V. UP OFFSET TO 3" VTR TD 4" SS S=2% 4" CWV S=1% 4" CO TD PROPOSED 1500 GAL. CAP. GREASE INTERCEPTOR 2-WAY CLEAN-OUT 4" CO 4" CO 2" V. UP 7 FD2 4" CO 4" SS S=2% 17 FS FS FS FS FS FS FS FS 3"V. 3" V. UP OFFSET TO 3" VTR FS 4" CWV S=2% 4" SS S=1% (M) BEER COOLER (N) CHECKSTAND (M) PRODUCE COOLER (N) CREMERIA ISLAND (N) BAKERY & KITCHEN FREEZER PRODUCE JUICE BAR (N) PAN DULCE (N) BAKERY PRODUCE PREP (N) CUSTOMER SERVICE (N) CHECK CASHING (N) BAKERY & KITCHEN COOLER (N)SAFE ROOM (N) HALL/ BACKSTOCK (N) LA COCINA (N) BAKERY PREP DINING AREA (E) FREEZER (N) DAIRY COOLER (N) HALL / BACKSTOCK (N) MEAT SERVICE (E) HALL/ BACKSTOCK (N) MEAT COOLER (N) MEAT PREP SALES AREA (M) TORTILLERIA PREP 1 S5 NEUTRAL RESTROOM (M) TORTILLERIA PREP 2" V. UP 2" V. UP 1-1/2" V. 2" V. 2" V. 2" V.4" SS S=1% 2" SS S=2% 4" CO-1 2" V. UP 2" SS S=2%4" SS 4" SS S=2% CO-3 3" SS S=2% 4" GW S=2% 4" GW S=2% 3" GW S=2% 3" GW S=2% 2" GW S=2% 4" GW S=2% 4" GW S=2% 2" V. UP 7 2" V. 2" V. 2" V. UP 4" GW S=2% ~ SANITARY SEWER @2% SLOPE I.E. = -6.71' 2" V. 2" V. 2" V. 2" V. 4" GW INLET PIPE I.E. = -4.53' 4" GW S=2% 3" GW S=2% 4" CO-2 INV. = -1.0' NEUTRAL RESTROOM 2" V. UP 3" GW S=2% 4" CO-1 INV. = -18" 2" V. 2" V. UP 2" V. 2" V. 4" CO 4" GW S=2% 4" GW S=2% 4" GW S=2% 4" SS. S=2% 4" SS. S=2% 3"W. 2" V. UP (TYP) I.E. = -3.39'(@1% SLOPE) 4" GW S=2% 4" GW S=2% 4" GW S=2% 4" GW S=2% 3" SS S=2% 4" GW S=2% 4" GW S=2% 4" GW S=2% 4" GW S=2% 4" GW S=2% 4" CWV S=2% 4" CWV S=2% 4" GW S=2% 4" GW S=2% 4" CLEAN-OUT STARTING I.E. = -1'-0" 4" CLEAN-OUT STARTING I.E. = -1'-0" 4" SS. S=2% 4" SS. S=2% 4" SS S=2% P.O.C. - I.E.=-4.95' 2" V.2" V. 2" V. 2" V.2" V. 2" V.2" V.2" V. 4" GW S=2% 2" V. 2" VENT BEL. GRD. (TYP.) 4" GW S=2% 4" GW S=2% 2" V. UP 7 2" V. UP (TYP) 4" SS S=2% IM 10 10 FS 2" V. UP 7 2" SS S=2% 18 18 18 18 18 18 18 18 HS HS FS HSFS FS S2 FS FS FS HS 3" SS S=2% FS HS FS2 EEW FS2 FS2 4" CWV S=1% 4" GW S=2% TD 2" V. UP OFFSET TO 2" VTR 7 UR CO-3 2" V. FS2 CO-3 3" VTR FS FS FS 4" SS. S=2% FS 3" CO CLEAN-OUT STARTING I.E. = -1'-0" 3" V. UP OFFSET TO 3" VTR 3" CWV S=2% 3" CWV S=2% FS FS 2" V. UP 7 2" V. UP 7 2" V.2" V. 4" GW S=2% 4" GW S=2% 2" V. UP 7 7 7 3" GW S=2% 4" GW S=2% 2" SS. S=2% 3" SS S=2% 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 PLUMBING FLOOR PLAN - WASTE & VENT 1 2 3 4 POC - CONNECT NEW 4" SANITARY LINE TO EXISTING 6" MINIMUM SANITARY LINE IN APPROX. AREA. CONTRACTOR TO COORDINATE EXACT LOCATION, SIZE, FLOW DIRECTION AND SITE OBJECTS ( BUILDING STRUCTURE/ COLUMN). CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ALL EXISTING SEWER PIPE AND PROPOSED INVERT ELEVATION, PRIOR TO START OF ANY WORK. 5 ALL VENTS THRU ROOF SHALL BE MINIMUM OF THREE FEET VERTICALLY OR TEN FEET HORIZONTALLY FROM ANY FRESH AIR INTAKES. KEYED NOTES 6 SHEET NOTES ALL PLUMBING ROUGH-IN WORK AND FINAL CONNECTIONS TO ALL FOOD SERVICE AND RELATED EQUIPMENT AS SHOWN ON THE KITCHEN EQUIPMENT CONTRACTOR'S PLANS TO BE PERFORMED BY THE CONTRACTOR PER NATIONAL AND LOCAL CODES. 1. THE PLUMBING CONNECTIONS, SPECIFICATIONS AND DIMENSIONS SHOWN ON THESE PLANS ARE FOR FOOD SERVICE EQUIPMENT ONLY. SEE ARCHITECT'S PLAN SET FOR ALL OTHER PLUMBING REQUIREMENTS FOR THIS PROJECT. 8. UNLESS OTHERWISE SPECIFIED IN THESE PLANS OR OTHER WRITTEN CONTRACTS, IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO PROVIDE ALL PLUMBING-TYPE MATERIALS INCLUDING VALVES, TRAPS, LINE STRAINERS, FLOOR SINK COVERS, PRESSURE REGULATORS, SIPHON BREAKERS, ETC. 2. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL DIRECT SINK WASTE LINES AND ALL INDIRECT EQUIPMENT WASTE LINES AS SHOWN ON PLANS PER LOCAL CODES, INCLUDING TRAPS, TAIL PIECES, LINE STRAINERS, AND WALK-IN CONDENSATE WASTE LINES, AS REQUIRED. INDIRECT WASTE LINE ROUTING THROUGH CABINETS SHALL BE IN A MANNER SO AS TO MAXIMIZE USABLE STORAGE SPACE. 3. ALL INDIRECT WASTE LINES TO HAVE A 2" MINIMUM AIR GAP.4. FLOOR SINKS SHALL BE FURNISHED AND INSTALLED BY THE PLUMBING CONTRACTOR IN LOCATIONS SHOWN, AND SUPPLIED WITH 3/4 GRATE OR AS SPECIFIED. AREA DRAINS, IF REQUIRED, SHALL BE VERIFIED WITH THE ARCHITECT. 5. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT THE LOCATIONS FOR ALL MECHANICAL REQUIREMENTS WHICH REQUIRE FLOOR PENETRATIONS DO NOT CONFLICT WITH STRUCTURAL MEMBERS IN THE FLOOR. 6. THE GENERAL CONTRACTOR SHALL SUPERVISE THE LOCATION OF ALL FLOOR DRAINS ON THE JOB SITE SO AS TO ENSURE THE BEST SLOPE POSSIBLE OF THE SURROUNDING FLOOR THESE DRAINS. 7. DAMAGES TO THE STRUCTURE DURING DEMOLITION OF PLUMBING WORK SHALL BE RESTORED BACK TO THE SAME CONDITION AS EXISTING. 9. CONTRACTOR TO VERIFY EXISTING CONDITION IN FIELD. CONTRACTOR TO VERIFY EXACT POINT OF CONNECTION. 4" W DN & 2" VENT UP FROM WATER CLOSET. 2" W DN & 1-1/2" VENT UP FROM ALL DIRECT DRAIN SINK FIXTURES. ALL PLUMBING INSTALLATION IS NEW UNLESS NOTED AS (E) EXISTING.10. 2" W DN & 1-1/2" VENT UP FROM MOP SINK. 7 VENT FROM FS/FD, BELOW FLOOR AND UP THE WALL. CONTRACTOR IS RESPONSIBLE TO VERIFY BEST ROUTING IN FIELD. 8 9 10 ALL EXISTING PLUMBING FIXTURES WITHIN THE EXISTING RESTROOM TO REMAIN. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITION AND DO PROPER MAINTENANCE TO ALL EXISTING FIXTURES. PLUMBING FIXTURE INDIRECTLY DRAINS TO THE ADJACENT FLOOR SINK. SHALL HAVE A 2" MINIMUM AIR GAP. 11 PLUMBING CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY EXACT LOCATION OF EXISTING SUMP PUMP AT THE LOADING DOCK. SHALL DO PROPER MAINTENANCE AND CHECK CONDITION OF ALL PIPING, FITTINGS, AND ACCESSORIES. 12 COOKING EQUIPMENT INDIRECTLY DRAINS TO THE ADJACENT FLOOR SINK. SHALL HAVE A 2" MINIMUM AIR GAP. 13 ISLAND VENT PER CODE - SEE ISLAND VENTING ON DETAIL #12 ON SHEET P-5.1. 14 VENT UP IN FALSE COLUMN AND/OR W/ PIPE COVER. 15 2" V. UP - OFFSET 2" V.T.R. 5/FT. FROM EXTERIOR WALL. 16 1-1/2" V. UP - OFFSET 2" V.T.R. 5/FT. FROM EXTERIOR WALL. 17 PROPOSED 1500 GALLON CAPACITY GREASE INTERCEPTOR, JENSEN PRECAST. CONTRACTOR SHALL REFER TO LOCAL CODE AND MANUFACTURER'S INSTALLATION AND OPERATING MANUAL, PRIOR TO START OF ANY WORK. "VERIFY IN FIELD" OR "EXISTING" MEANS THE CONTRACTOR IS TO CONFIRM THE ITEM SHOWN ON THE DRAWING (I.E. EQUIPMENT, PIPE, ETC.) EXISTS AT THE SITE AND IS IN GOOD WORKING CONDITION. SHOULD THE CONTRACTOR FIND THAT THE EQUIP., PIPE, ETC. IS NOT THE EQUAL TO THAT SHOWN ON THE DRAWING, IT IS TO BE REPLACED, IF THE CONTRACTOR HAS ANY QUESTION WHETHER IT IS EQUAL TO WHAT IS SHOWN ON THE DRAWING, THE CONTRACTOR IS TO CONTACT THE DESIGN ENGINEER AND TENANT'S PROJECT MANAGER FOR APPROVAL. CONTRACTOR IS TO NOTIFY TENANT'S PROJECT MANAGER AND DESIGN ENGINEER IN WRITING OF ALL REPLACEMENT ITEMS PRIOR TO CONSTRUCTION. 11. IT IS REQUIRED THAT THE PLUMBING CONTRACTOR MUST VISIT THE JOBSITE TO FAMILIARIZE HIMSELF WITH MAJOR ITEMS SUCH AS STRUCTURAL ELEMENTS AND OTHER EXISTING JOB CONDITIONS THAT MAY AFFECT HIS WORK. ADDITIONALLY, PLUMBING CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH ITEMS AS WASTE, VENTS, WATER LINES, ETC. 12. 3-COMPARTMENT SINK - P.C. TO EXTEND INDIRECT WASTE LINE FROM (3) SINKS WITH LEVER DRAINS TO FLOOR SINK. DRAIN SHALL HAVE A MINIMUM 2" AIR GAP. REFER TO DETAIL 3 ON SHEET P-401 FOR ADDITIONAL INFORMATION. MEZZANINE - WASTE & VENT ADDITIONAL PIPING NOTES: a. ABS AND PVC PIPING EXPOSED TO SUNLIGHT SHALL BE PROTECTED BY WATER-BASED SYNTHETIC LATEX PAINTS. (CPC 906.1). b. SUSPENDED PIPING SHALL BE SUPPORTED AT INTERVALS NOT EXCEED THOSE SHOWN IN TABLE 313. 2022 CPC SEC. 313.3 13.PREP SINK (INDIRECT) HAND SINK TRENCH DRAINS FLOOR DRAIN DFU INTERCEPTOR VOLUME 90 1250 GALLONS Where the flow rate of directly connected fixture(s) or appliance(s) have no assigned DFU values, the additional grease interceptor volume shall be based on the known flow rate (gpm) (LIs) multiplied by 30 minutes TYPE 12 18 125 DFU UNIT TOTALFU 1 2 QTY 12 20 36 40 --6 (LENGTH)X (WIDTH) X (DEPTH) = -4 - 172 1500 GALLONS 125 DFU 3-COMP SINK (INDIRECT) PLUMBING CODE 2019 TABLE 1014.3.6 JENSEN PRECAST JP1500G WITH SAMPLE BOX GREASE INTERCEPTOR CALCULATION 216 2000 GALLONS FLOOR SINK 226 52 128" x 67" x 60" = 514,560 SQ. IN. 514,560 SQ. IN./ 231 = 2,227.5 GAL. 2,227.5 x .75 FILL FACTOR = 1670.6 GAL. * 18 FLOOR SINK - SHALL RECEIVE INDIRECT DISCHARGE FROM THE REFRIGERATION UNIT. FINISHED FLOOR SHALL BE SLIGHTLY ELEVATED AND TRIP HAZARD FREE. SHALL BE CONNECTED TO THE SANITARY SEWER. AN EFFORT SHOULD BE MADE TO ENCLOSE ALL PLUMBING, CONDUIT, AND GAS LINES WITHIN WALLS. WHERE THIS IS NOT POSSIBLE, MULTIPE RUNS OR CLUSTERS OF PIPING SHOULD BE FURRED IN, ENCASED IN APPROVED RUNWAY OR OTHER APPROVED SEALED ENCLOSURE. ALL CONDUIT, PLUMBING, ETC., NOT CONCEALED WITHIN WALLS, MUST BE INSTALLED AT LEAST SIX (6) INCHES OFF THE FLOOR AND 1/2" INCH AWAY FROM WALLS. ALL EXPOSED FLEX CONDUIT IS TO BE "SEAL-TIGHT" OR EQUIVALENT. (114257). 14. MOP SINK 331 HOLD- 420 W 17th St3/7/2025 CL CL So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 GA S GA S GA S GA S GA S GA S 6 2 5 GAS GAS 2" GAS 657 CFH 1-1/2" GAS 407 CFH 1-1/4" GAS 327 CFH 9 1-1/2" GAS 1000 CFH 12 3 GAS 10 FS2 FS FS FS FS FS FS FS FS FS FS FS 16 16 16 16 FS16 FS16GA S GA S FS FS16 EXISTING GAS SERVICE BY GAS CO. REPLACE EXISTING GAS METER W/ NEW GAS METER W/ LABELED S.O.V. @ +18" A.F.G.; GAS CO. TO INSTALL GAS METER REGULATOR TO DELIVER GAS PRESSURE OF 2 PSI AND GAS SERVICE TO METER - GENERAL CONTRACTOR TO PAY FOR INSTALLATION AND/OR ANY AND ALL RELATED TRENCHING AND FINISH GRADE REPAIR (ASPHALT-ETC.) INSTALL FULL LINE SIZE (KOSO) EARTHQUAKE SHUT- OFF VALVE (MODEL 314) 2-1/2" E.Q.S.O.V. - PACIFIC SEISMIC PRODUCTS MODEL #314 2-1/2" RISE UP EXTERIOR BLDG. WALL W/ UNI-STRUT EVERY 10/FT O.C. - CONTINUE ON ROOF. 15 15 15 15 15 15 FS16 FS 16 FS16 FS16 16 FS16 FS 16 FS16 FS16 GAS GAS GA S (M) BEER COOLER (N) CHECKSTAND (M) PRODUCE COOLER (N) CREMERIA ISLAND (N) BAKERY & KITCHEN FREEZER PRODUCE JUICE BAR CONCOURSE (N) PAN DULCE (N) BAKERY PRODUCE PREP (N) CUSTOMER SERVICE (M) TORTILLERIA PREP (N) CHECK CASHING (N) BAKERY & KITCHEN COOLER (N)SAFE ROOM (N) MEN RESTROOM (N) WOMEN RESTROOM (N) HALL/ BACKSTOCK (N) LA COCINA (N) BAKERY PREP DINING AREA (E) FREEZER (N) DAIRY COOLER (N) HALL / BACKSTOCK (N) MEAT SERVICE (E) HALL/ BACKSTOCK (N) MEAT COOLER (N) MEAT PREP SALES AREA (M) TORTILLERIA SERVICE EXISTING 50 GAL. WATER HEATER 1 & 2 - 38,000 BTU/H ABOVE CEILING 1-1/4" GAS 250 CFH GA S GA S 1" GAS 335 CFH 2" GAS 1335 CFH GA S GA S GA S GA S GA S 2" GAS 793 CFH 3/4" GAS 60 CFH 1" GAS 76 CFH 2" GAS 733 CFH 7 1" GAS 112 CFH 12 NEW A.O. SMITH BTH-120 WATER HEATERS 3 & 4 60 GAL. CAP. 120,000 BTU/H FS16 FS16 FS16FS16 1" CD 15 1" CD 15 1" CD 15 1" CD 15 1" CD 15 1" CD 15 1" CD 151" CD 15 1" CD 15 1" CD 15 1" CD 15 1" CD 15 S=1% S=1%S=1% S=1% S= 1 % S= 1 % S= 1 % S=1% GAS GAS GAS GAS GAS 8 FS FS FS FS FS16 16 16 16 16 16 FS16 2" GAS 1335 CFH 1" GAS 160 CFH 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 P.O.C. CONNECT NEW GAS LINE TO GAS METER AND REGULATOR. REFER TO ARCH. DRAWING FOR THE APPROXIMATE LOCATION, OUTSIDE THE BUILDING. 1" G. DN. WITH GC. CONNECT TO CHARBROILER, 80 CFH. KEYED NOTES 3/4" G. DN. WITH GC. CONNECT TO DOUBLE FRYER, 90 CFH. 1" G. DN. WITH GC. CONNECT TO GRIDDLE, 90 CFH. 1-1/4" G. DN. WITH GC. CONNECT TO 6 BURNER RANGE, 215 CFH. 3/4" G. DN. WITH GC. CONNECT TO STOCK POT BURNER, 160 CFH. SHEET NOTES ALL PLUMBING ROUGH-IN WORK AND FINAL CONNECTIONS TO ALL FOOD SERVICE AND RELATED EQUIPMENT AS SHOWN ON THE KITCHEN EQUIPMENT CONTRACTOR'S PLANS TO BE PERFORMED BY THE CONTRACTOR PER CALIFORNIA AND LOCAL CODES. 1. THE PLUMBING CONNECTIONS, SPECIFICATIONS AND DIMENSIONS SHOWN ON THESE PLANS ARE FOR FOOD SERVICE EQUIPMENT ONLY. SEE ARCHITECT'S PLAN SET FOR ALL OTHER PLUMBING REQUIREMENTS FOR THIS PROJECT. 4. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL GAS SUT-OFF VALVES FOR EACH PIECE OF EQUIPMENT WITH PERMANENT I.D. TAGS AS WELL AS THE MAIN GAS VALVE(S). 2. IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL WATER HEATERS FOR THIS PROJECT AND TO ENSURE ADEQUATE WATER SUPPLY FOR THE FOOD SERVICE EQUIPMENT. COORDINATE EXACT LOCATION OF WATER HEATER IN FIELD. 3. PLUMBING CONTRACTOR SHALL PROVIDE FULL LINE SIZE DISCONNECT COUPLER.5. INSTALL NEUTRALIZER KIT ON THE 3/4" CONDENSATE DISCHARGE PRIOR TO MOP SINK. CONTRACTOR TO ROUTE 3/4" CONDENSATE LINE AND T&P VALVE FROM WATER HEATER TO MOP SINK UNDERNEATH. CONTRACTOR TO FOLLOW LOCAL CODES. 1-1/4" G. DN. WITH GC. CONNECT TO TORTILLA/TOSTADA FRYER, 335 CFH. 1-1/4" G. DN. WITH GC. CONNECT TO TORTILLA OVEN, 1000 CFH. REFRIGERATION /PLUMBING CONTRACTOR SHALL BE RESPONSIBLE TO INSTALL CONDENSATE DRAINS FROM THE COOLER AND FREEZER EQUIPMENT. DRAIN LINES WILL NOT BE ACCEPTED TO CROSS OVER FRY STORAGE RACKS / EQUIPMENT. A MINIMUM 1/2" CLEARANCE BETWEEN THE DRAINING LINE AND THE WALLS WITHIN THE REFRIGERATION UNIT SHALL BE PROVIDED. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING HEAT TRACE, AS NEEDED. SEE REFRIGERATION DRAWING, SHEET R2.0, FOR CONDENSATE PIPING. 3/4" G. DN. WITH GC. CONNECT TO ROTISSERIE, 112 CFH. PLUMBING CONTRACTOR TO INSTALL CONDENSATE DRAIN PIPING FROM MECHANICAL UNIT(S) ON ROOF. PIPE DOWN THE WALL AND DISCHARGE TO LAVATORY / HAND SINK TAIL PIECE, AS SHOWN. REFER TO DETAIL #8 ON SHEET P-400. CONTRACTOR / OWNER'S REPRESENTATIVE SHALL COORDINATE AND REQUEST FOR A NEW GAS METER WHICH CAN HANDLE THE NEW TOTAL GAS DEMAND OF 3,499 CFH. SHALL COORDINATE WITH THE LOCAL GAS COMPANY THE MINIMUM INITIAL SUPPLY PRESSURE OF 8.0 IN. W.C. CONTRACTOR SHALL PROVIDE G.C. AND FLEX CONNECTION TO EACH GAS FIXTURES. PLUMBING CONTRACTOR TO INSTALL CONDENSATE DRAIN PIPING FROM FAN COIL UNIT. PROVIDE P-TRAP. REFER TO DETAIL #7 ON SHEET P-400. PLUMBING CONTRACTOR TO PROVIDE 12" X 12" FLOOR SINK(S) SET FLUSH WITH FINISHED FLOOR 1/2 EXPOSED (FOR EASY CLEANING) WITH 1/2 GRATE COVERS WITHIN A 24" X 24" BLOCK OUT. ALL TO COMPLY WITH LOCAL CODE. SHALL REFER TO THE MANUFACTURER AND OPERATING MANUAL OF THE REFRIGERATION UNITS, PRIOR TO MAKING FINAL CONNECTIONS. REFER TO REFRIGERATION, SHEET R2 FOR EXACT LOCATION. PLUMBING CONTRACTOR TO INSTALL CONDENSATE DRAIN PIPING FROM MECHANICAL UNIT(S) ON ROOF. PIPE DOWN THE WALL AND DISCHARGE TO FLOOR SINK, AS SHOWN. 3/4" G. DN. WITH GC. CONNECT TO 24" GRIDDLE, 128 CFH. PROVIDE LINE SIZE (AUTO) SOLENOID VALVE - INSTALL ABOVE CEILING. CONTINUE PRIMARY DRAIN ABV. CLG. - DN. IN WALL - INDIRECTLY DISCHARGE TO THE FLOOR SINK W/ 1" AIR GAP - EXTEND SECONDARY DRAIN 1" BEL. FINISH CLG. & TERMINATE - VERIFY EXACT UNIT LOCATION AND DETAILS W/ HVAC DWG'S PRIOR TO START OF ANY WORK. COND. DRAIN UP THRU ROOF W/ FLASHING - CONNECT TO HVAC EQUIPMENT ON ROOF W/ 3" DEEP WET VENTED TRAP - EXTEND DRAIN AND PIPING BEL. ROOF @1% - DN. IN WALL - INDIRECTLY DISCHARGE TO AN APPROVE RECEPTOR W/ 1" AIR GAP - VERIFY EXACT UNIT LOCATION & DETAILS W/ HVAC DWG'S PRIOR TO START OF WORK. CONTINUE PRIMARY DRAIN ABV. CLG. - DN. IN WALL - INDIRECTLY DISCHARGE TO MOP SINK W/ 1" AIR GAP - EXTEND SECONDARY DRAIN 1" BEL. FINISH CLG. & TERMINATE - VERIFY EXACT UNIT LOCATION AND DETAILS W/ HVAC DWG'S PRIOR TO START OF ANY WORK. 19 18 17 21 13 20 16 15 9 14 10 8 7 6 5 4 3 2 1 11 12 22 23 24 LENGTH (FEET)PIPE SIZE 1/2"3/4"1"1-1/4"1-1/2"2"2-1/2" CAPACITY (CFH)50 72 151 284 583 873 1680 2680 TABLE 1215.2(1) - SCHED 40 METALLIC PIPE 150 40 83 157 322 482 928 1480 10 172 360 678 1390 2090 4020 6400 SIZING BASED ON 2022 CPC TABLE 1215.2(1) LESS THAN 2 PSI INLET PRESSURE 90 52 110 207 424 635 1220 1950 70 60 126 237 486 728 1400 2230 20 118 247 466 957 1430 2760 4400 GAS EQUIPMENT SCHEDULE Department Name Family QT YManufacturerModel KITCHEN Specialty Cooking Stock Pots 1KINTERAKSP2/919590 36" 6 Burner RANGES 1WOLFC36S-6BN Fryer 1VULCANLG300 TORTILLERIA Tortilla Oven 1CASA HERRERA FO 120 / 32 BTU TOTAL 215 160 90 1000 TOTAL 2,858=TOTAL DEVELOPED LENGTH = 200 FEET SCHEDULE 40 STEEL PIPE 2022 CPC TABLE 1215.2(1) & 1215.2(2) WATER HEATER A.O. SMITH BTH-150 2 300 ROOF TOP UNITS 2 2 RTU - 1, 2 RTU - 3, 4 Roof Unit Roof Unit 196 BTU INPUT 215 160 90 1000 150 117 98 234 Countertop CHARBROILER 1CPG351CRCPG36NL 8080 Tortilla Chip and Tostada Fryer 1Superior Food Machinery CF100 335335 LENGTH (FEET)PIPE SIZE 3/4"1"1-1/4"1-1/2"2"2-1/2" CAPACITY (CFH)353 726 1090 2090 3340188200 GAS PIPE CHART SIZING BASED ON 2022 CPC TABLE 1215.2(2) 3" 5900 8.0 IN. W.C. INLET PRESSUREPIPE MATERIAL: SCHEDULE 40 METALLIC PLUMBING FLOOR PLAN - GAS & CONDENSATE EXISTING WATER HEATER - Rheem XG50T12HN38U1 2 7638 175 37 77 144 296 443 854 1360 200 34 71 134 275 412 794 1270 Pizza Oven 1LINCOLN2424G-0002 6060 Rotisserie 1DOREGRILLMAG 40/8 GAS 112112 3/4" G. DN. WITH GC. CONNECT TO PIZZA OVEN, 60 CFH. PROVIDE NEW WATER HEATER, ON PLATFORM, AS SCHEDULED. REFER TO DETAIL #2 ON SHEET P4.0 FOR MORE INFORMATION. 25 HOLD- 420 W 17th St3/7/2025 RTU 1 RTU 2 RTU 3 RTU 4 2-1/2" GAS RISE UP EXTERIOR BLDG. WALL W/ UNI-STRUT EVERY 10/FT O.C. - CONTINUE ON ROOF. GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GA S GAS 1" GAS 98 CFH 1" GAS 8 in. w.c. 117 CFH 1-1/2" GAS 8 in. w.c. 1452 CFH GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GASGASGAS GA S GASGASGASGAS GASGASGASGAS 2" GAS low pressure 1335 CFH 2" GAS DOWN low pressure 793 CFH 1"GPRV 1 TDL=30' 1" GAS 8 in. w.c. 117 CFH 2" GAS 8 in. w.c. 1569 CFH 1"GPRV 1 TDL=70' 2-1/2" GAS 8 in. w.c. 2362 CFH 2-1/2" GAS 8 in. w.c. 2460 CFH 1" GAS DOWN 8 in. w.c. 300 CFH GA S GA S GA S 1" GAS 8 in. w.c. 300 CFH 1-1/4" GAS 8 in. w.c. 398 CFH 3/4" GAS 8 in. w.c. 98 CFH 2-1/2" GAS 8 in. w.c. 2858 CFH RR 3/4" COLD WATER STUB AND HOSE BIBB FURNISHED AND INSTALLED BY P.C.. VERIFY EXACT LOCATION IN THE FIELD DRAIN AND OVERFLOW BY PLBG CONTRACTOR PLUMBING CONTRACTOR TO PIPE OVERFLOW, DUMP DRAIN AND MAKE-UP TO GAS COOLER REFRIGERATION GAS COOLER SEE REFRIGERATION DWG SHEET R8.0 FOR ADDT'L INFO. 6 5 PLUMBING CONTRACTOR TO PIPE 3/4" WATER CONN. TO 3/4" FPT MAKE-UP TO GAS COOLER REFER TO SHEET R8.0 FOR ADDITIONAL INFORMATION 7 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 PLUMBING ROOF PLAN SHEET NOTES: REFER TO PLUMBING LEAD SHEETS FOR LEGENDS, ABBREVIATIONS AND GENERAL NOTES. PLUMBING VENT THRU ROOF OUTLETS SHALL TERMINATE NO LESS THAN 3 FEET FROM PROPERTY LINE, 3 FEET FROM OPENINGS INTO BUILDING, AND 10 FEET FROM A FORCED AIR INLET. CONTRACTOR SHALL VISIT THE SITE, VERIFY SITE CONDITIONS, IDENTIFY ALL OBSTRUCTIONS, EXACT ROUTING OF DUCTWORK SHALL BE CONTRACTORS RESPONSIBILITY. PROVIDE REQUIRED TRANSITIONS DUCT FITTINGS ETC. TO AVOID ANY OBSTRUCTIONS. KEYED NOTES: 1 2 3 4 PACKAGE GAS/ELECTRIC AC UNIT WITH ROOF CURB. ROOF MOUNTED MAKE-UP AIR FAN. ROOF MOUNTED EXHAUST FAN. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT THE LOCATIONS FOR ALL MECHANICAL REQUIREMENTS WHICH REQUIRE ROOF PENETRATIONS DO NOT CONFLICT WITH ANY STRUCTURAL MEMBERS. THE GENERAL CONTRACTOR SHALL SUPERVISE THE LOCATION OF ALL THE EXISTING ROOF DRAINS ON THE JOB SITE SO AS TO ENSURE PROPER ROOF STORM WATER DRAINAGE. 1" COND. DRAIN DN THRU ROOF W/ FLASHING - CONNECT TO HVAC EQUIPMENT ON ROOF W/ 3" DEEP WET VENTED TRAP - EXTEND DRAIN PIPING BEL. ROOF @ 1% - DN. IN WALL - SPILL INTO FLOOR SINK W/ 1" AIR GAP - EXTEND SECONDARY DRAIN 1" BEL. FINISH CLG. & TERMINATE - VERIFY EXACT UNIT LOCATION AND DETAILS W/ HVAC DWG'S PRIOR TO START OF ANY WORK. SEE SHEET P-4.0 FOR CONTINUATION. GPRV #MAKE GPRV #1 - 1"PIETRO FIORENTINI MODEL ORIFICE SIZE 30052OPD FULL PORTED REGULATOR (NO ORIFICES) VENTLESS REGULATOR SPRING PART NUMBER COLOR BLACK 2 PSI INLET PRESSURE PRESSURE REGULATOR SETTING 6.0" w.c.- 14.0" w.c. GPRV SCHEDULE STEP-DOWN MANIFOLD TO HAVE THE FOLLOWING: 1) MUST HAVE TWO FEET CLEARANCE FRONT AND SIDES 2) MUST BE INSTALLED IN A READILY ACCESSIBLE LOCATION. 3) MUST BE REACHED SAFELY NO MORE THAN APPROXIMATELY 48 INCHES OFF THE WORKING SURFACE. ATTIC INSTALLATIONS ARE UNACCEPTABLE. REQUIREMENTS FOR NEW STEP-DOWN MANIFOLDS FOR NON-RESIDENTIAL 2 PSIG, 5 PSIG AND ABOVE SYSTEMS TEE BALL VALVE TEE UNION UNION TEE BALL VALVE PLUG 1 2" BALL VALVE REDUCER PLUG PLUG 1 2" BALL VALVE 1 2" BALL VALVE REDUCER REDUCER REDUCER 1 2" BALL VALVE PIETRO FIORENTINI GOVERNOR OVER PRESSURE DEVICE (OPD) SEE GPRV SCHEDULE FOR SIZE & SEE GAS PLAN FOR LOCATION NOT TO EXCEED 48" NATUR A L GAS F L O W NATUR A L GAS F L O W DETAIL #1 - N.T.S. STEP-DOWN GAS REGULATOR DETAIL 3. 1. 2. 4. 5. ADDITIONAL PIPING NOTES:6. a. ABS AND PVC PIPING EXPOSED TO SUNLIGHT SHALL BE PROTECTED BY WATER-BASED SYNTHETIC LATEX PAINTS. (CPC 906.1). CONTRACTOR SHALL REFER TO REFRIGERATION DRAWINGS, PRIOR TO START OF ANY WORK ON THE REFRIGERATION EQUIPMENT. SHALL ALSO REFER TO INSTALLATION AND OPERATING MANUAL OF THE EQUIPMENT TO ENSURE PROPER PERFORMANCE. CONTRACTOR SHALL PROVIDE AN APPROVED TYPE 3/4" LINE SIZE CHECK VALVE OR BACKFLOW PROTECTION. SHALL FIELD VERIFY EXACT LOCATION. 5 6 ROOF RECEPTOR - ROUTE PIPING DOWN TO FLOOR BELOW AND CONTINUE TO SANITARY SEWER LINE ON THE GROUND FLOOR LEVEL. 7 LENGTH (FEET)PIPE SIZE 3/4"1"1-1/4"1-1/2"2"2-1/2" CAPACITY (CFH)353 726 1090 2090 3340188200 GAS PIPE CHART SIZING BASED ON 2022 CPC TABLE 1215.2(2) 3" 5900 8.0 IN. W.C. INLET PRESSUREPIPE MATERIAL: SCHEDULE 40 METALLIC HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. ANY MATERIAL, COMPONENT OR VENDOR CHANGE MUST HAVE PRIOR APPROVAL BY THE APPLICABLE PRODUCT ENGINEERING DEPARTMENT. TEMPERATURE & PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE LEGEND TEMPERATURE CONTROL PROBE DRAIN FULL PORT BALL VALVE CHECK VALVE TEMPERATURE GAGE WATER FLOW SWITCH PIPE T&P TO OPEN DRAIN FINISHED FLOOR 1. Preferred piping method. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. 2"/W x 18/GA. GALV. SHEET METAL STRAP TERMINATE NOT LESS THAN 10/FT. FROM, OR NOT LESS THAN 3/FT. ABOVE, AN OPENABLE WINDOW, DOOR, OPENING, AIR INTAKE OR VENT SHAFT, OR NOT LESS THAN 3/FT. IN EVERY DIRECTION FROM LOT LINE, ALLEY AND STREET EXCEPTED 12" MIN. ROOF BOOT/FLASHING (FIELD SUPPLIED) ROOF IN HORIZONTAL POSITION. MOUNT ALL CHECK VALVES NOTE: NOTE: WATER HEATER STORED ON S/S PLATFORM OR CONCRETE CURB. NOTE: WATER HEATER PROVIDED BY THE PLUMBING CONTRACTOR. SUPPORT (FIELD SUPPLIED) NOTE: WATER HEATER INSTALLATION AND START UP IS BY THE PLUMBING CONTRACTOR. ALL JOINTS SHALL BE SEALED WITH PVC CEMENT (TYPICAL) BALL VALVE (S.O.V.) UNION (TYP.) 4" VENT 4" COMBUSTION AIR 2"HW 140°2"HW 140° CIRCUIT SETTER FOR BALANCING. 2" CW 1 1/4"HWR NOTE: REFER TO PLANS FOR WATER PIPING SIZES. VACUUM RELIEF VALVE WATTS N36 ET-1 EXPANSION TANK AMTROL ST-35-CL PLATFORM NOTE: 2" CW INLET AIR VENT & AIR SCOOP 3/4" HOSE BIBB BETWEEN THE RECIRC. PUMP AND BALL VALVE (S.O.V.) WH 3 1 A.O. SMITH BTH-150 MXI 150,000 BTU/HR INPUT - 100 GALLON PROVIDED BY G.C. MECHANICAL CONTRACTOR TO PROVIDE TIMER, WIRING, CONDUIT, SWITCH, AND INSTALLATION. COORDINATE ELECTRICAL POWER TO COMPONENTS WITH DIVISION 26. NOTE: WATER HEATERS OR HEAT RECLAIM TANKS SHALL BE PLUMBED IN ACCORDANCE WITH THE MANUFACTURE'S SECIFICATIONS (WITH THE EXCEPTION OF ANY AND ALL STATE, COUNTY OR CITY ORDENANCES. ) THE COLD WATER PIPING AND RECIRCULATION LOOP PIPING SHALL NOT BE CONNECTED TO THE HOT WATER HEATERS OR HEAT RECLAIM TANKS DRAIN PORT THERMOMETER WITH SHUT-OFF VALVE (TYP.) PALMER#35AL BALL VALVE (S.O.V.) CHECK VALVE WATTS LF600 (CP-1) G.C. SHALL INSTALL VERTICAL TYPE RECIRCULATION PUMP ONLY - PROVIDE POWER AS REQUIRED AQUASTAT 2"HW 140° 1 1/4"HWR 2"CW HOT WATER SUPPLY - SEE P-3.1 FOR CONT. COLD WATER SUPPLY - SEE P-3.1 FOR CONT. 1 1/4"(140°) HWR STUD WALL 3/8"Ø AUTOMATIC AIR RELEASE VALVE WATTS N36 3" 2" C W I N L E T 2" H W 1 4 0 ° 2" C W 4' M A X . 12 " M I N . WH 4 PIPE T&P TO OPEN DRAIN FLOOR SINK ALL HOT & COLD WATER SUPPLY AND RETURN PIPING TO BE INSULATED WITH INNOFOAM POLYOLEFIN INSULATION. SIZES: 1/2" TO 1" PIPE = 1" THICK 1 1/4" TO 6" PIPE = 1 1/2" THICK K = 0.27 BTUH IN./SQ.FT. OR LESS NOTE: WH 3 WH 4 HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 120 V. 1Ø 60HZ 7 DAY TIME SWITCH PARAGON 4 PST SWITCH & TIME CONTROL MODEL #7007-00 E PUMP START/STOP AQUASTAT SETTINGS (DEGREE F): PUMP# START STOP CP-1 110 120 PUMP CONTROL MODULE WITH DRY CONTACT THAT NEEDS TO SEE CLOSURE FOR PUMP TO START. CP-1 120v. 1Ø 60HZ FLOOR SLAB NOTE OF TRAP PRIMER VALVE. IN PLUMBING WALL FOR SERVICING PROVIDE 12x12 ACCESS PANEL COLD WATER MAIN 1/2" SUPPLY TO FREQUENTLY USED FIXTURE CONNECT TO FLOOR DRAIN PROVIDED WITH 1/2" PRIMER TAP 1/2" SOFT COPPER UNION TRAP PRIMER VALVE (IN WALL BEHIND ACCESS PANEL) TP-1 FS / FD 9 P-6.1 FURNISHED AND INSTALLED BY PLUMBER WIRED BY ELECTRICAL CONTRACTOR. FURNISHED AND INTALLED BY ELECTRICAL CONTRACTOR. ALL WIRING BY ELECTRICAL CONTRACTOR. LOCKING NUT PIPE CLEVIS HANGER SUPPORT NUT HEAVY DUTY HANGER ROD PIPE INSULATION 8" LONG MINIMUM SHEET STEEL SADDLE 16 GA. ZINC COATED HEAVY DUTY CLEVIS HANGER VAPOR BARRIER HANGER ROD LOCKING NUT SUPPORT NUT +24" A.F.F. ESCUTCHEON BALL VALVE PLATED CHROME WATER SUPPLY LINE SILICONE CAULK AROUND WALL PENETRATION EARED 90 %% 1X BLOCKING 5/8" GYP. BD. STUD WALL EQUIPMENT BY OWNER (VERIFY EXACT LOCATION) SIZE OF FLARE OR THREADED CONNECTION FLEX CONN. BY P.C. UNLESS NOTED OTHERWISE VARIES PIPE SLAB PIPE RISER CLAMP TYPE GR SPONGE SIDE VIEW SECTION ISOLATION MATERIAL RESILIENT CHROME OR PLASTIC ESCUTCHEON (AT TOILET & LAV'S USE TYPE "IGR" ISOLATED ESCUTCHEON) PARTITION PENETRATION ISOLATING PIPE CLAMP DRYWALL STUD ISOLATING PIPE CLAMP ATTACHMENT TO STUDS ACOUSTICAL SEALANT MATERIAL TOP VIEW ACOUSTO-CLAMP HIGH EAR FRONT VIEW SIDE VIEW ACOUSTO-CLAMP FRONT VIEW TYPE AC ISOLATOR CLEVIS HANGER SINGLE HORIZONTAL RUNS NO VAPOR BARRIER INSULATION CLEVIS HANGER SINGLE HORIZONTAL RUNS WITH VAPOR BARRIER INSULATION (Tons)DRAIN SIZE Up to 20 21-40 41-90 1 1/4" 3/4" 1" TABLE 8-2 (CPC 2007) EQUIPMENT CAPACITY MIN. PIPE 91-125 126-250 2" MIN. 3" 6" DIELECTRIC UNION A/C UNIT NOTE: TRAP 1 1/2" OVERFLOW DRAIN PAN BY MECHANICAL SUB-CONTRACTOR ALL INTERIOR CONDENSATE DRAIN PIPING SHALL BE INSULATED. TYPE 'DWV' COPPER TUBING WITH WROUGHT COPPER FITTING SLOPE TO APPROVED RECEPTOR DRAIN LINE SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE UNIT. INSIDE OUTSIDE 2432-03 RISER-3" 2432-06 RISER-6" 2432-12 RISER-12" AS REQUIRED SAMPLE BOX WEIGHT: 1,250 LBS. BOX DESIGN LOAD: H-20 TRAFFIC SAMPLE BOX MUST BE PLACED ON SUITABLE BASE OF COMPACTED SOIL OR UNDISTURBED EARTH IN TRAFFIC CONDITION. FOR COMPLETE DESIGN AND PRODUCT INFORMATION CONTACT JENSEN PRECAST. VARIABLE ELEVATION SECTION PLAN VIEW COVERS AND RISERS REMOVED PIPE CONNECTOR (Z-LOK) DETAIL PIPE CONNECTOR CAST INTEGRALLY IN WALL. PIPE O.D. (INCHES) 4.25" MINIMUM TO 6.25" MAXIMUM SEE Z-LOK PIPE CONNECTOR PAGE FOR ADDITIONAL INFORMATION CONNECTOR SHOWN WITH PIPE INSTALLED 32" DIA. 17" 32" VARIABLE VARIABLE 36-1/2" MINIMUM SEE CONNECTOR DETAIL COMPACTED FILL OR UNDISTURBED EARTH 12" MODEL 2432Z-1 24" DIA. SAMPLE BOX WITH PIPE CONNECTORS STRAIGHT THROUGH MAIN IW WASTE SIDE ENTRANCE TO MAIN SEWER ONLY 2 PIPE Ø'S MIN. LENGTH SIZE PER DRAWINGS DEEP SEAL P-TRAP SS TAILPIECE SIZE PER DRAWINGS MOTOR RATED MAINTENANCE TOGGLE SWITCH. 2" WASTE LEG WASTE SLOPE SINK HALF WALL FLOOR CEILING NOTE: 1. INCREASE TO 2" IF LENGTH EXCEEDS 20-FEET HORIZONTAL OR 60-FEET TOTAL DEVELOPED LENGTH PRIOR TO TIE-IN. 2. WHERE BACK-SPLASH COUNTER SPACE IS AVAILABLE, THE VENT LOOP SHALL PROJECT INTO THE SPACE AS HIGH AS POSSIBLE. 3. FOR PIPE SIZES & CONTINUATION REFER TO DRAWINGS. 4. FOR UNDERGROUND INSTALLATION PIPE SHALL BE TREATED AS REQUIRED BY CODE. 90º ELBOW L.R. (OR EQUIVALENT ONE PIECE FITTING) NEAREST WALL 1 1/2" P-TRAP 1 1/2" VENT, NOTE #1 PLUMBING CODE MANUAL NO. 909.0 SPECIAL VENTING FOR ISLAND FIXTURES NOTE: RAISE RETURN VENT AS HIGH AS POSSIBLE UNDER THE DRAIN BOARD 45º ELBOW(OR EQUIVALENT ONE PIECE FITTING) 2" VENT UP IN WALL 2" CLEANOUT 2" VTR 2" WASTE @ 1/4" SLOPE 2" FOOT VENT @ 1/4" SLOPE 2" PIPE 2" CLEANOUT LAVATORY OR SINK SLIP-JOINT FITTING. BY PLUMBING CONTRACTOR CONDENSATE DRAIN DOWN IN WALL. SEE PLANS FOR SIZE. ESCUTCHEON PLATE VENT WALL WASTE CLEANOUT PLUG FINISHED FLOOR TRAP MEMBRANE CLAMP FLOOR SLAB ON GRADE PROVIDE ROUND SECURED NICKEL BRONZE ADJUSTABLE TOP WITH "CO" CAST IN COVER. PROVIDE CLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). PROVIDE PLASTIC PLUG IN CAST IRON BODY. CLEAN THE TOP OF EXPOSED FCO AFTER INSTALLATION. AS REQUIRED FOR DEPTH OF SEWER WASTE PIPE BELOW FLOOR. SANITARY OR STORM SEWER LINE SAME SIZE AS SEWER UP TO 4" MAXIMUM. LONG SWEEP ELBOW AT END OR TURN OF RUN. COMBINATION WYE AND EIGHTH BEND IN RUN. ENTER TOP OF PIPE. TWO-WAY CLEANOUT FOR LOCATION, SEE DWG DIRECTION OF FLOW NOTE: 1.LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE GREATER THAN 45 DEGREES, AT 50' INTERVALS ON STRAIGHT RUNS, AND WHERE SHOWN ON PLANS. 2.PROVIDE BACKFILL PER ARCHITECTURAL SPECIFICATIONS. 3.LOCATE CLEANOUTS WHERE THERE IS 18" CLEAR AROUND. 4.CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS. CLAMP w/ BOLT & NUT ASSEMBLY LENGTH IS 2 FEET. ING COLLAR AND SEEPAGE PAN. TWO PERCENT. MAXIMUM 5' ON 2" SLOPE WASTE AT WASTE OR 6' ON 3". OTHER VENTING METHODS MAY BE USED IF APPROVED BY LOCAL CODE. MAXIMUM TAILPIECE MEMBRANE CLAMP-REDUCING TRAP PROVIDE TRAP PRIMER MAXIMUM 15' WHERE ENLARGED WASTE LINE IS USED AS A COMBINATION WASTE AND VENT SYSTEM. NOTE: 1.LOCATE FLOOR DRAIN/SINK WHERE SHOWN ON DIMENSIONED ARCHITECTURAL PLAN. IF FLOOR STRUCTURE INTERFERES WITH FLOOR SINK, MOVE SIDEWAYS IF POSSIBLE, OTHERWISE MOVE BACK. ALWAYS LOCATE WHERE EASILY ACCESSIBLE, BUT NOT IN FOOT TRAFFIC. 2.IF SITUATION IS FLOOR SLAB ON GRADE, PROVIDE BACKFILL PER SPECIFICATIONS. IF CONCRETE FLOOR IS NOT EXISTING, SET DRAIN IN PLACE AND POUR AROUND IT, OR BLOCK OUT AND POUR IN LATER. 3.IF CONCRETE FLOOR IS EXISTING, SAW CUT OR CORE DRILL IT. SET DRAIN BODY IN PLACE AND POUR AROUND IT. 4.TOP OF THE FLOOR SINK / DRAIN TO BE SET 1" ABOVE FINISHED FLOOR, BEVEL EDGES WHERE POSSIBLE TO PREVENT TRIPPING HAZARD. [CPC 421.1] 5.IF SITUATION IS FLOOR NOT ON GRADE, REFER TO "FLOOR PENETRATION" DETAIL FOR VENTS. 6.PROVIDE TRAP PRIMER FOR FLOOR DRAINS IN RESTROOMS. CONCRETE FLOOR SLAB W/ 1/2" TILE ON TOP TOP OF DRAIN FLUSH WITH TILE DESIGNER NOTE: VERIFY IF FLOOR SINKS NEED TO BE RAISED ABOVE FINISH FLOOR 1TYP. PIPE SUPPORT DETAIL 2COMBINATION WASTE & VENT SYSTEM SCHEMATIC 3TYP. RISER CLAMP DETAIL 4FLOOR CLEAN OUT DETAIL 5TYP. EQUIPMENT CONNECTION 6SOUND ISOLATOR DETAILS 7CONDENSATE DRAIN TRAP 8CONDENSATE TO LAV/SINK TAILPIECE DETAIL 9FLOOR SINK DETAIL 10TRAP PRIMER DETAIL 11CIRC PUMP WIRING DIAGRAM 12ISLAND SINK VENT DETAIL 14GREASE INTERCEPTOR 13SAMPLE BOX DETAIL 2" USE C.I. PIPE TO BRASS (TYP.) APPROX. 6" ABOVE OVERFLOW LEVEL. CONNECT URINAL TO SOIL TEES W/ 90° LONG TURN DRAINAGE FITTING (TYP.) PROVIDE ACCESS PANEL IN PLUMBING WALL FOR CLEAN OUT AND SERVICING 2" VENT HDR 15URINAL DRAIN DETAIL 2000 GALLON GREASE INTERCEPTORS KJP2000G KJZ2500G 2500 2000 5'-9" 4'-11" 16'-10" 15'-11" 6'-0" 6'-0" 5'-0" 5'-0" 4'-9" 4'-9"6' MAX. 10-01-03 JP2000-JZ5000_Grease-W.dwg 2003 Jensen Precast BE COMPACTED TO 90% MAXIMUM DRY DENSITY, OR TO REQUIREMENTS OF THE PROJECT THE EXCAVATION SHALL BE BEDDED WITH SUITABLE GRANULAR MATERIAL AND SHALL SUITABLE NATIVE OR SUB-BASE SHALL BE PREPARED TO HANDLE ANTICIPATED LOADS. FOR COMPLETE DESIGN AND PRODUCT INFORMATION TANK DESIGNED FOR H-20 TRAFFIC WHEEL LOAD WITH DRY SOIL CONDITIONS GEOTECHNICAL ENGINEER. CONTACT JENSEN PRECAST. (WATER TABLE BELOW TANK). 'C' TANK HEIGHTWIDTH 'A' OVERALL LENGTH 'B' EXCAVATIONOUTLET 'D' INLET WIDTH EXCAVATION MINIMUM 'E'LENGTH MINIMUM 5'-11" 6'-9" 16'-11" 17'-10"5' MAX. MAX. LIFT WEIGHT 19,200 22,700 24" DIA. CAST IRON FRAME AND COVER WITH GASKET HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 3 11 6 5 7 10 IW 10 8 16 12 TYPICAL GAS CONNECTION TO EQUIPMENT 1 2 FLOOR SLAB ON GRADE MEMBRANE CLAMP AS REQUIRED FOR DEPTH OF SEWER NO HUB CAST IRON PIPE BELOW FLOOR. SANITARY OR STORM SEWER LINE NOTE: 1. PROVIDE ROUND SECURED NICKEL BRONZE ADJUSTABLE TOP WITH "CO" CAST IN COVER. 2. PROVIDE CLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). 3. PROVIDE PLASTIC PLUG IN CAST IRON BODY. 4. CLEAN THE TOP OF EXPOSED FCO AFTER INSTALLATION. NOTE: TRAP PRIMER VALVE AND DISTRIBUTION UNIT BY PRECISION PLUMBING PRODUCTS INC. OREGON #1 CORROSION RESISTANT BRASS TRAP PRIMER WITH A COPPER RESERVOIR AND A PVC DIAPHRAGM.VALVE TRAP PRIMER VALVE (IN WALL BEHIND ACCESS PANEL) FLOOR DRAIN FINISHED FLOOR SUPPLY TO FREQUENTLY USED FIXTURE CW 1/2" UNION MAXIMUM OF 4 1/2" SOFT COPPER CONNECT TO FLOOR DRAIN PROVIDED WITH 1/2" PRIMER TAP TRAP PRIMER PIPING DETAIL FLOOR CLEANOUT 1/2" NOT USED GAS PIPE ROOF PENETRATION INDIRECT WASTE EQUIPMENT CONNECTION TYPICAL WATER HAMMER ARRESTOR DETAIL CONDENSATE DRAIN PIPING DETAIL WALL CLEANOUT COLUMN OR PARTITION AS SHOWN ON FLOOR PLANWHERE CLEANOUT IS CONCEALED IN A CHASE OR PARTITION, PROVIDE A ROUND 18 GAUGE STAINLESS STEEL COVER WITH BEVELED EDGES AND FLATHEAD MACHINE SCREW CONCRETE FLOOR SLAB 1. PROVIDE WCO WHERE SHOWN ON PLAN. 2. CLEANOUT FACE SHALL TERMINATE AT WALL SURFACE. PROVIDE PIPE EXTENSION IF REQUIRED. NOTE: METAL BRAIDED BRONZE FLEXIBLE HOSE WITH WELDED ENDS. (TYP.) ADAPT TO UNIT AS REQUIRED ADAPTER (TYP.) PLATFORM CURB ROOF SCREWED CLEANOUT PLUG PRIMARY DRAIN CAPPED BELOW ROOF RATED ASSEMBLY 6" (MAX) 3" (MIN.) 1" 12" DOUBLE BRAIDED FLEXIBLE CONNECTION (FLEXONICS) (RATED FOR EXTERIOR LOCATION) UNION GAS SUPPLY INLET GAS SHUT-OFF VALVE TEE FITTING NIPPLE 3" MIN CAP EQUIPMENT AS CLOSE TO THE INLET OF THE EQUIPMENT AS PRACTICAL HOT WATER AND COLD WATER SUPPLY TO FIXTURE PIPING DOWN IN WALL ABOVE CEILING LOCATION ISLAND CABINET LOCATION HOT WATER AND COLD WATER SUPPLY TO FIXTURE HW CW PIPING ABOVE CEILING WHA WHA IN CABINET STAINLESS STEEL ACCESS PANEL ABOVE CEILING BELOW CEILING CW HW PIPING ABOVE CEILING WHA WHA CEILING PROVIDE CLEANOUTS IN TURNS/ENDS OF PIPE DISCHARGE INTO CENTER OF FLOOR SINK WITH MIN. 1" AIR GAP MAKE CONNECTION TO EQUIPMENT AS REQUIRED PROVIDE TRAP AND 6" HIGH PIPE VENT OPEN TO ATMOSPHERE WHEN DRAIN LINE IS LONGER THAN 5' SLOPE PIPE AS MUCH AS POSSIBLE TOWARD DISCHARGE NOTE: ROUTE PIPE INCONSPICUOUSLY AND UNOBTRUSIVELY. HANG PIPE AS REQUIRED. REFER TO LOCAL CODES FOR FURTHER INFORMATION. MAKE-UP AIR UNIT (SEE MECH. DWG.) CW HW COVER VALVE BODIES WITH INSULATION, BUT NOT UNIONS. ROOF INSULATION ROOF DECK GALVANIZED STEEL CLAMP. DO NOT CLAMP PIPE TIGHT. ROOFING ERICO RPS50H6 PIPE SUPPORT AND DETAIL INSTALLATION SEE WWW.ERICO.COM PROVIDE 1/2" UNICELLULAR ELASTOMERIC INSULATION OR APPROVED EQUAL ON DOMESTIC HOT AND COLD WATER PIPES AND ALL CEILING SPACES IN WALLS AND CHASES. MITER THE INSULATION AT TEES AND ELBOWS. SEAL ALL JOINTS WITH ADHESIVE NOTE: 1.PROVIDE 1/2" FIBERGLASS INSULATION WITH ALL-SERVICE JACKET WITH VAPOR BARRIER OR APPROVED EQUAL ON ALL COLD WATER, CONDENSATE, AND STORM DRAIN PIPE UP TO 4". 2.PROVIDE 1" INSULATION OR APPROVED EQUAL ON STORM DRAIN PIPE ABOVE 4" SIZE. 3.PROVIDE 1" FIBERGLASS INSULATION WITH ALL-SERVICE JACKET OR APPROVED EQUAL ON DOMESTIC HOT WATER PIPING. 4.REFER TO SPECIFICATIONS FOR FURTHER INFORMATION REGARDING INSULATION. INSTALL ALL ITEMS PER SPECIFICATIONS AND MANUFACTURER'S INSTRUCTIONS. 5.MAINTAIN VAPOR BARRIER ON COLD PIPING BY MEANS OF SEALANT AND TAPE. 6.FLAME-SPREAD AND SMOKE-DEVELOPED INDEXES SHALL NOT EXCEED 25/50. 7.SEAL EXPOSED ENDS OF FIBERGLASS INSULATION WITH ADHESIVE MASTIC. ROOF INSULATION ROOF DECK NOTE: 1.LOCATE AT TURNS OF PIPE, AT 4' SPACING FOR PLASTIC PIPE, AND AT THIS SPACING FOR METAL PIPE: 5"=16' 4"=14' 3"=12' 2-1/2"=11' 2"=10' 1-1/2"=9' 1-1/4"=8' 1"=7' 3/4"=6'. PLACE BASE SHEETS ON ROOFING BEFORE GRAVEL IF ANY. SET BLOCKS FREE ON BASE SHEETS. STACK BLOCKS AND NAIL THEM TOGETHER WHERE REQUIRED TO ELEVATE PIPING. 2.PRIMER COAT AND PAINT EXTERIOR GAS PIPE SAFETY YELLOW COLOR. 3.18"x18"x1/2" THICK ROOF WALKWAY MATERIAL FOR BASE SHEET. ("CAREY-TRED" OR PER ARCHITECTURAL SPECIFICATIONS.) FOODSERVICE EQUIPMENT UTILITY INLET HOSE & FITTING QUICK DISCONNECT UL LISTED SHUT-OFF VALVE WALL FACE OF BUILDING COORDINATE WALL REINFORCING WITH GENERAL CONTRACTOR RESTRAINING CABLE NOTE: 1.IF UTILITY IS NOT AT FULL HEIGHT SHOWN, PROVIDE PIPING WITH ELBOWS TO RAISE INLET FINISHED FLOOR PROVIDE ROOFING BOOT COORDINATE WITH ROOFER NOTE: MITER THE INSULATION AT TEES AND ELBOWS SO THAT THERE ARE NO GAPS AT JOINTS IF POSSIBLE, THEN TAPE THEM. OTHERWISE FILL THE GAPS WITH BLANKET FIBERGLASS MOULDED PVC FITTING COVERS TAPE JOINTS OF FIBERGLASS INSULATION PROVIDE A ONE FOOT LENGTH OF NONCOMPRESSIBLE INSULATION AT HANGERS FOR ALL PIPE 2" AND LARGER REFER TO OTHER DETAILS FOR TREATMENT OF INSULATION AT PENETRATION OF WALLS, FIREFLOORS, FLOORS, AND FIREWALLS STEPPED FLEXIBLE PVC OR NEOPRENE COUPLING CLAMPED TO FLASHING AND PIPE WITH STAINLESS STEEL SCREW CLAMPS. RIGHT AND LEFT NIPPLE & COUPLINGS 1998 CPC SEE #1211.10 ROOFING OVER METAL FLASHING BY ROOFING CONTRACTOR ROOF SUPPORT REFER TO DETAIL ELBOWS TO COMPENSATE FOR PIPE EXPANSION NOTE: 1.REFER TO PLANS FOR PIPE SIZE(S) AND LOCATION(S). 2.WELDED OR SCREWED FITTINGS AS SPECIFIED FOR PIPE SIZE. 3.LOCATE PENETRATION MINIMUM 18" FROM ADJACENT WALLS. SLEEVE ROOF IF REQUIRED ANCHOR PIPE TO ROOF DECK OR JOISTS 14PIPE INSULATION DETAIL 15GAS QUICK DISCONNECT ROOF PIPE PENETRATION SEE FLOOR PLAN FOR RECEPTACLE LOCATION. 3/4" CO NOTE: 1.INSTALL PIPE A MINIMUM OF 76" ABOVE FINISH FLOOR , ANCHORED TO WALL OF BOX WITH SUPPORTS AT MAXIMUM SIX FOOT CENTERS. 2.USE TYPE "M" HARD COPPER TUBE AND FITTINGS WITH LEAD-FREE SOLDER JOINTS. 3.SLOPE HORIZONTAL PIPE AT MINIMUM TWO PERCENT. 4.KEEP DRAIN LINE FROM EVAPORATOR AS HIGH AS POSSIBLE UNDER THE EVAPORATOR BACK TO THE WALL TO MAXIMIZE SHELF SPACE UNDER THE COIL. 5.REFER TO LOCAL CODE FOR INDIRECT DRAIN REQUIREMENTS. DISCHARGE TO FLOOR DRAIN OR FLOOR SINK WITH AIR GAP OF TWICE PIPE DIAMETER. MAKE CONNECTION TO COIL AS REQUIRED PROVIDE CLEANOUT IN TURNS AND ENDS OF PIPE WALK-IN COOLER OR FREEZER BOX. COORDINATE ROUTING OF DRAIN WITH SHELVING IN WALK-IN BOX DX COIL PROVIDE 1" ELASTOMERIC INSULATION OVER HEAT TRACING ON CONDENSATE LINE (FOR FREEZER BOX ONLY) BY WALK IN BOX INSTALLER, (ELECTRIC HEATING CABLE IS BY CONTRACTOR). DRILL HOLE IN SIDE OF BOX AND PROVIDE SILICONE SEAL AROUND PIPE PENETRATION. FLOOR SINK WALK-IN BOX CONDENSATE DRAIN 43-COMP SINK - WATER CONNECTION 93-COMP SINK - INDIRECT DRAIN13ICE MACHINE WATER FILTER ICE MAKER DETAIL SPRAY ATTACHMENT SWING FAUCET INSULATED POTABLE WATER SUPPLY PIPING. SHUT OFF VALVES TYP. FLOOR LINE UNIONS TYP. CHECK VALVES TYP. 3/4" SYMMONS 7-200 TEMP CONTROL VALVE IN ACCESS PANEL CEILING TO HOT WATER RETURN LINE SEE PLBG. PLAN FOR PIPE SIZES S.O.V. (TYP.) UNIONS (TYP.) 3/4" BALANCING VALVE (TYP.) INSTALL ABV. CLG. WALL BRACKET 3/4" TO HOT WATER SUPPLY FROM HOT WATER SUPPLY 140°F HOT WATER LOOP FROM COLD WATER SUPPLY 3/4"3/4"3/4" 3/4" FILTER HOUSING EQUIPMENT (SUPPLIED BY OWNER INSTALLED BY PC) 1" SHUTOFF VALVES SUPPORT PIPE AS REQ'D. 1" FW TO OVENS CONNECT TO EXISTING 1" CW STUBBED UP ON PIPING CURB DURING PREVIOUS PHASE 1" CW SUPPLY AS SHOWN ON PLANS. CONNECT TO EXISTING 1" CW STUBBED UP DURING PREVIOUS PHASE. SEE DETAIL 14/P301 1" BYPASS TYPICAL HANDSINK FLOOR SINK WITH 1/2 GRATE CLEANOUT PLUG (TYP) LEVER DRAIN (TYP) 3 COMPARTMENT PREP SINK 2" AIR GAP 3" PROVIDE FITTINGS AS EQUIRED 3/4" CW. STRAINER 3/4"UNION(TYP.) 3/4"DRAIN TO F.S. ROW RCW NOTE: PROVIDE POWER AS REQUIRED PRESS GAUGE NOTE: SECURE UNIT TO WALL WITH UNISTRUT P-1000 CHANNELS AND PIPE CLAMPS-2LOCATIONS 3/4" TO MISTING SYSTEM UNDER PRODUCE CASE WORK, CONNECT THRU GATE VALVE AND PRESSURE REGULATOR SET AT 45 PSI 3/4"RED.PRESS.TYPE BACKFLOW PREVENTOR WITH FUNNEL DRAIN. ABV. CASE WORK REVERSE OSMOSIS SYSTEM ABV. CASE WORK 3/4" RCW, 3/4" TO HDR AT 6" AFF BEHIND PRODUCE CASES, & 1/2" TO QUICK DISCONNECT LOCATED AT BULK FLORAL CASE 3/4" PRESS. REG. SET @ 15PSI ABV. CASE WORK 17PRODUCE PREP. RP/PRV ASSEMBLY FOR MISTING SYSTEM HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 WM EXISTING PIPE BELOW GRADE VERIFY IN FIELD 2" CW (74.5) 2" PRESSURE REDUCING VALVE WILKINS 500XL (E)1-1/2" WATER METER AT SIDEWALK VERIFY IN FIELD ~2" BACK FLOW PREVENTER WILKINS 975XL3 HB 2.5 2"CW (77 FU) BLDG. WALL 3/4"HWR SCALE: NOT TO SCALE DOMESTIC COLD AND HOT WATER RISER DIAGRAM 1" HWR 2" CW(44.5) 1-1/4" HWR 3/4"CW 1" CW(5) 1" HW(4) 1" CW (8.5) A 2" CW (74.5) HB 2.5 FU BLDG. WALL B 2" CW (74.5) CP AIR RELEASE VALVE MAX. 4 FT. FROM PUMP INLET 1. DRAWINGS ARE DIAGRAMATIC & DOES NOT REPRESENT ACTUAL CONNECTIONS. 2. SEE DETAIL 1/P-3.0 FOR WATER HEATER PIPING DIAGRAM. SHEET NOTES 1" HW(5) TO CASE (TYP.5) HSS3 1" H W 1 C W 6 F U HB2 1" H W ( 6 ) 1" C W ( 7 ) S4HB3 HS 1" H W NEUTRAL GENDER RESTROOM 1" H W 2" CW(28) 1" HW(6) 2" CW(31.5) 1-1/2"HW(24) 2"CW(37.5)2" CW(32.5) MISTING KIT 3/4"CW PRVBFP HB 1 FU ½" COLD WATER PIPE SIZING (TYPE "L" COPPER PIPE) BASED ON PIPE SIZE 3/4"1"1¼"1½"2"2½"3" 3.6 PSI/100 FT. AND MAX. VELOCITY OF 8 FPS CW FLUSH TANK 1 6 13 431 7192854185 HW 1 6 13 245 4062846119 CW FLUSH VALVE 0 0 0 295 66601382 HSHB3 S1S3 PAN DULCE 1" H W 1" C W 6 F U BALL VALVE (TYP.) S3HS S1HB2 34 " H W R HALL / BACKSTOCK 3/ 4 " ( 1 ) 1" C W 2. 5 F U HS 1" H W R TORTILLERIA PREP 1" WATER METER FLOWS WM-NLC 1" BACKFLOW PREVENTER WILKINS 975XL2 MIXER HB4 1" H W ( 3 ) 1" C W ( 4 ) 1" H W R JUICE BAR COFFEE S5 HS IM ESPRESSO MACH. BALL VALVE (TYP.) 1" H W ( 7 ) 1" C W ( 9 ) 1" H W R 1" WATER METER FLOWS WM-NLC 1" BACKFLOW PREVENTER WILKINS 975XL2 MIXER MIXER BAKERY PREP PROOFER OVEN 1-1/4" CW (14.5) 1" HW(5) 2" CW (65.5) 1" HW(7) 1" H W 1" C W 4 F U HB2 HSS3 CREMERIA ISLAND 3/ 4 " H W R BFP 1-1/4" CW (16.5) 1" HW(7) A2" CW(45) B1-1/4"HW(18) B1-1/4" HWR MEAT PREP. S2 MOP SINK 3/ 4 " H W 3/ 4 " C W 3 F U 3 WH 4 WH BALL VALVE (TYP.) 1" C W 1 F U EEW PRODUCE PREP 1/ 2 " H W 1/ 2 " C W 1 F U SINK HAND 1/ 2 " H W 1/ 2 " C W 1 F U SINK HAND S.O.V. (TYP.) BALL VALVE (TYP.) BALL VALVE (TYP.) BALL VALVE (TYP.) BALL VALVE (TYP.) SINK LAV SINK LAV 3/ 4 " C W 2" C W 18 F U INSTANTANEOUS WATER HEATER CLOSET WATER CLOSET WATER URINAL 1- 1 / 4 " 4 F U 1- 1 / 4 " 5 F U 1- 1 / 4 " 5 F U 1-1/2"(9)2"(14) BALL VALVE (TYP.) 2" CW(18)2" CW(22) 4 F U S.O.V. (TYP.) S.O.V. (TYP.) S.O.V. (TYP.) HB 3/ 4 " C W 1 F U 2" CW(30.5)2" CW(32.5) 1-1/2"HW(29) S.O.V. (TYP.) S.O.V. (TYP.) S.O.V. (TYP.) S.O.V. (TYP.) S.O.V. (TYP.) 1"CW(7.5) 3/ 4 " C W 1 F U 1" HW(11) 1-1/4" CW(20.5) HB 3/ 4 " C W 1 F U 3/4" CW 2 FU HB 1.0 FU 1" HW(7) 1" CW 1 fu 2" CW(36.5) 2 ET 1-1/4" HWR 1" HWR1" HWR TBV - THERMOSTATIC BALANCING VALVE (TYPICAL) TBV - THERMOSTATIC BALANCING VALVE (TYPICAL) TBV - THERMOSTATIC BALANCING VALVE (TYPICAL) TBV - THERMOSTATIC BALANCING VALVE (TYPICAL) TBV - THERMOSTATIC BALANCING VALVE (TYPICAL) 1" HWR 1"CW 2 FU 1"CW 1.5 FU 1"CW 1.0 FU 1"CW 0.5 FU 3/4"CW 3 FU 3/4"HW 4 FU 1"HW(6) 1"CW 6 FU 3/4"CW 4 FU TBV - THERMOSTATIC BALANCING VALVE (TYPICAL) 1" CW(3.5)1" HW(3)3/4"(2)3/4"(1)1" CW(4) 1" HW(4) 3/4"CW(2) 3/4"HW(2) 1"CW(3) 1"HW(3) 3/4"(1) 3/4"(1) 1"CW(5) 1"HW(5) 1-1/2"HW(25) 1-1/2"HW(36) 1"CW(4) 1"HW(4) 1-1/2"CW BFP 1/2" CW 0.5 FU 3. PROVIDE STUB-OUT FOR ALL FIXTURE. NEUTRAL GENDER RESTROOM URINAL 1- 1 / 4 " 4 F U 1-1/4"(5) S.O.V. (TYP.) S1 1/ 2 " H W 1/ 2 " C W 1 F U SINK HAND HB4 2" CW(35.5) 1-1/2"HW(26) 1/ 2 " H W 1/ 2 " C W 1 F U SINK HAND 1" CW(7.5) 1/ 2 " H W 1/ 2 " C W 1 F U SINK HAND 1-1/4" CW(15.5) 1" HW(6) HS 1"CW(3) 1"HW(1) 2 WH 1 WH CP AIR RELEASE VALVE MAX. 4 FT. FROM PUMP INLET 1 ET(EXIST.)(EXIST.) (EXIST.) 1" H W ( 6 ) 1" C W 3/ 4 " H W R ~~ ~~ C 1-1/2"HW(18) SEPARATE WATER HEATER SYSTEM TO RE-USE THE EXISTING WATER HEATER INSTALLED FIXTURE 3 COMPARTMENT SINK 24" X 24" 3 COMPARTMENT SINK 18" X 18" 2 COMPARTMENT PREP SINK 1 COMPARTMENT PREP SINK RESTROOM SINK DUMP/BAR SINK JANITOR / MOP SINK 287,980 BTU/H TOTAL GALLONS PER HOUR CONSUMPTION 440 HAND SINKS 1 4 3 3 25 14 75 168 1 2 2 1 1 11 2 1 1 1 1 1 14 14 6 6 15 6 28 28 12 6 15 66 GPH REQUIREMENTS AS DETERMINED BY THE HEALTH DEPARTMENT AND MANUFACTURERS DATA SHEETS QTY PER FIXTURE NUMBER OF FIXTURES FIXTURE TOTALS SIZING REQUIREMENTS FOR 'NEW' STORAGE TYPE WATER HEATERS COLD & HOT WATER HOSE REEL 7 1 6 42 TANK TYPE GAS WATER HEATER SIZING FORMULA - TOTAL GPH X (77) DEGREE RISE IN WATER REQUIRED X 8.33 LB (WEIGHT OF A GALLON OF WATER) THEN DIVIDED BY THERMAL EFFICIENCY (0.98% - SEE WATER HEATER SPECS ON SHEET P3.0 = BTU INPUT REQUIRED TO FURNISH HOT WATER NECESSARY 2 x 150,000 BTU provided FIXTURE 3 COMPARTMENT SINK 18" X 18" 1 COMPARTMENT PREP SINK 63,288 BTU/H TOTAL GALLONS PER HOUR CONSUMPTION 74 HAND SINKS 1 3 14 42 1 2 1 1 14 6 14 6 TANK TYPE GAS WATER HEATER SIZING FORMULA - TOTAL GPH X (77) DEGREE RISE IN WATER REQUIRED X 8.33 LB (WEIGHT OF A GALLON OF WATER) THEN DIVIDED BY THERMAL EFFICIENCY AS SET NATIONALLY BY NSF AT .75 OR 75 PERCENT = BTU INPUT REQUIRED TO FURNISH HOT WATER NECESSARY GPH REQUIREMENTS AS DETERMINED BY THE HEALTH DEPARTMENT AND MANUFACTURERS DATA SHEETS QTY PER FIXTURE NUMBER OF FIXTURES FIXTURE TOTALS SIZING REQUIREMENTS FOR THE 'EXISTING' STORAGE TYPE WATER HEATERS COLD & HOT WATER HOSE REEL 1 1 6 6 2 x 38,000 BTU provided HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 GROUND FLOOR YCO 1500 GALLONS JENSEN GREASE INTERCEPTOR FCO 3"V 3" V 3"VTR 4"W(121) CO SEE BELOW FOR CONTINUATION ROOF 2% SLOPE 4"GW(125) SCALE: NOT TO SCALE GREASE WASTE & VENT RISER DIAGRAM 2% SLOPE CO 3" VTR 25 FU 2" 2"(2) CO 2" V. 2 FU 2" 2"(1) HS FS2 2"(2) CO S13-COMP SINK (S3) 2" V. 2 FU FS 2"(2) CO 2" V. 2 FU 4" CO 4"GW(6)4"GW(4)4"GW(7)4"GW(9) 2" V. 9 FU 2" V 4 FU 2" V 6 FU 2" V 7 FU FD 2"(2) CO 2" V. 2 FU 4"GW(18) FS 2"(2) CO 2" V. 2 FU TD 2"(3) CO FS 2"(2) CO 2" V. 2 FU FS 2"(2) CO 2" V. 2 FU TD 2"(3) CO FD 2"(2) CO 2" V. 2 FU 2" V. 3 FU 2" V. 3 FU 4" CO 2" V 7 FU 2" V 9 FU 2" V 11 FU 2" V 13 FU 2" V 7 FU 2" V. 4 FU 2" V 12 FU 2" V 16 FU 4"GW(5)4"GW(7)4"GW(9)4"GW(11)4"GW(14)4"GW(16) FS 2"(2)2"(2) 4"GW(10) FS FD 2"(2) 2" 2"(2) 3-COMP SINK (S3) TD 2"(1) HS 2" ( 1 ) BAKERY PREP BAKERY CREMERIA ISLAND IS L A N D V E N T CO 2" ( 3 ) 2" ( 1 ) 2"(3) 2" ( 2 ) 2" ( 2 ) 2" ( 2 ) 2" ( 2 ) 2"V(14) 2" VTR 14 FU 4"GW(1)4"GW(4)4"GW(6)4"GW(8)4"GW(12) 4" CO FD 2"(2) CO 2" V. 2 FU 4"GW(3) FD 2"(2) CO 2" V. 2 FU 2"(1) HS 2" V. 1 FU 4" CO 4"GW(5)4"GW(6) 2" VTR 6 FU 2"V(6) 2" VTR 21 FU FS2 2"(2) CO 2" V. 2 FU TD2 2"(3) CO FD2 2"(2) CO 2" V. 2 FU 2" V. 3 FU 4" CO 2" V 3 FU 2" V 5 FU 4"GW(3)4"GW(5)4"GW(7) LA COCINA 2"(1) HS 2" V. 1 FU 4" CO 2" 2"(2) CO 2" 3-COMP SINK (S3) 2" V. 2 FU 4"GW(1)4"GW(3) FS2 2"(2) CO S2 2" V. 2 FU 2" V. 4 FU 2" V. 2 FU 4"GW(5) 2" V 2 FU 2" V 6 FU 2" V. 7 FU 2" V 7 FU 2" V 14 FU 2" V. 21 FU FD2 2"(2) CO 4"GW(8) 2"(2) CO 2" V. 2 FU 4"GW(4)4"GW(6) FD2 2"(2) CO 2" V. 2 FU 2" V. 2 FU FD2 4" CO FS 2"(2)2"(2) 4"GW(7) FS FD 2"(2) 2"(1) HS 2" ( 1 ) JUICE BAR IS L A N D V E N T CO 2" ( 2 ) 2" ( 1 ) 2" ( 2 ) 2" ( 2 ) 2" ( 2 ) 2"V(11) 2" VTR 11 FU 4"GW(1)4"GW(3)4"GW(5)4"GW(11) 4" CO 2"(2) FS 2" 3-COMP SINK (S4) 2" VTR 8 FU 2" V 4 FU 2" V 2 FU 2" V. 8 FU GROUND FLOOR ROOF 4"GW(42) ~ 2" V. 25 FU GROUND FLOOR ROOF FD2 2"(2) CO 4"GW(18) FS 2"(2) CO 2" V. 2 FU 2" V 5 FU 4"GW(14)4"GW(16) FD2 2"(2) CO 2" V. 2 FU 2" V. 2 FU 2" V. 4 FU 2" V 7 FU 4"GW(12) 4"GW(80) B SEE ABOVE FOR CONTINUATION GRD FLOOR ROOF C 4" CO FIRST FLOOR ROOF FS 2"(2) CO 2" V. 2 FU 4"SS(26) FS 2"(2) CO 2" V. 2 FU 4"SS(24) 2"(1) HS 2" V. 1 FU TD 2"(3) CO 2" V. 3 FU 4" CO 4"SS(21) FS 2"(2) CO 3" V. 2"(2) LAV 2" V. 2 FU LAV 2" V. 1 FU 2" V. 1 FU UR 2"(2) CO 2"(2) CO FD WC 4"(4) CO WC 4"(4) CO 4" CO 2"V(18) 2" VTR 18 FU 2" V 4 FU 2" V 10 FU 2" V. 4 FU 2" V. 4 FU 2" V. 2 FU 2" V. 2 FU 2" V 2 FU 2" V 4 FU 2" V 8 FU 4"SS(8)4"SS(10)4"SS(14)4"SS(16)4"SS(18)4"SS(20) 2 FU 2" SS(1) 4"SS(28) 4"SS(46) 3" VTR 2 FU 2" VTR 1 FU 3" VTR 2 FU 2" VTR 1 FU 3"(2) CO 2" V. 2 FU 2" VTR 2 FU FS 3"(2) CO 2" V. 2 FU 2" VTR 2 FU FS FS 3"(2) CO 3" V. 2 FU 2" VTR 2 FU 4" CO 4"SS(2) 4"SS(42) FS 3"(2) CO 3" V. 14 FU 3" VTR 14 FU 4" CO 4"(2) FS 3"(2) FS 3"(2) FS 3"(2) FS 3"(2) FS 3"(2) FS 3"(2) 4"(4)4"(6)4"(8)4"(10)4"(12)4"(14) CO 2" V. 2 FU 2" VTR 4 FU 4"(10) 2" V. 4 FU 3"(2) CO 2" V. 2 FU FS TD2 2"(3) CO 2" V. 3 FU 4"SS(12) EEW 2" V. 1 FU COCO COCO CO CO CO 2" VTR 6 FU 2" V. 6 FU 4"(1)4"(4)4"(6)4"(8) FS 3"(2) CO 3" V. 2 FU 3" VTR 2 FU CO 4"(6) FS 3"(2) CO 3" V. 2 FU 3" VTR 2 FU 4" CO FS 3"(2) CO 3" V. 2 FU 3" COFS 3"(2) 3" VTR 2 FU FIRST FLOOR ROOF 3"SS(2)3"SS(4)4"SS(6)4"SS(4)4"SS(26)4"SS(40)4"SS(44)4"SS(46)4"SS(74) A A 4"SS(62) 4"GW(42)4"GW(53)4"GW(61) 4" GW(86)4" GW(98)4" GW(116) 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE2% SLOPE2% SLOPE2% SLOPE2% SLOPE (TYP)(TYP)(TYP)(TYP)(TYP) (TYP)(TYP)(TYP) (TYP)(TYP)(TYP) 2" V. 1 FU 4"SS(183) 2% SLOPE SCALE: NOT TO SCALE SANITARY SEWER WASTE & VENT RISER DIAGRAM 2"(1) HS 2" V. 1 FU 4" CO 2" FS2 CO 2" 3-COMP SINK (S3) 4"GW(3)4"GW(5) 2" V. 2 FU 2" V 2 FU 2" V. 5 FU GROUND FLOOR ROOF CO 2" VTR 5 FU SEE ABOVE FOR CONTINUATION ~ SEE BELOW FOR CONTINUATION ~ SEE BELOW FOR CONTINUATION GRD FLOOR ROOF PREP SINK (INDIRECT) HAND SINK TRENCH DRAINS FLOOR DRAIN DFU INTERCEPTOR VOLUME 90 1250 GALLONS Where the flow rate of directly connected fixture(s) or appliance(s) have no assigned DFU values, the additional grease interceptor volume shall be based on the known flow rate (gpm) (LIs) multiplied by 30 minutes TYPE 12 18 125 DFU UNIT TOTALFU 1 2 QTY 12 20 36 40 --6 (LENGTH)X (WIDTH) X (DEPTH) = -4 - 172 1500 GALLONS 125 DFU 3-COMP SINK (INDIRECT) PLUMBING CODE 2019 TABLE 1014.3.6 JENSEN PRECAST JP1500G WITH SAMPLE BOX GREASE INTERCEPTOR CALCULATION 216 2000 GALLONS FLOOR SINK 226 52 128" x 67" x 60" = 514,560 SQ. IN. 514,560 SQ. IN./ 231 = 2,227.5 GAL. 2,227.5 x .75 FILL FACTOR = 1670.6 GAL. * MOP SINK 331 FS2FS2 FS2 S2 2"(2) FD2 2"(2) CO 2" V. 2 FU 4"GW(1) 2" V 1 FU 2" V 3 FU PRODUCE PREP 3" VTR 37 FU FS 2"(2) CO 2" V. 2 FU TD 2"(3) CO FD2 2"(2) CO 2" V. 2 FU 2" V. 3 FU 4"GW(28)4"GW(30) MEAT PREP 2"(1) HS 2" V. 1 FU 4" CO 2" 2"(2) CO 2" 3-COMP SINK (S5) 4"GW(1)4"GW(3) FS2 2"(2) CO S2 2" V. 2 FU2" V. 2 FU 4"GW(9) 2" V 7 FU 2" V 9 FU 2" V. 37 FU FD2 2"(2) CO 2" V. 2 FU FD2 2"(2) CO 2" V. 2 FU 4"GW(5)4"GW(7) 2" V 5 FU 2"(1) HS 2" V. 1 FU 2"(2) CO 2" V. 2 FU FD2 2"(2) CO 2" V. 2 FU FS TD 2"(3) CO 2" V. 3 FU 2" V. 2 FU FD2 2"(2) CO 2"(2) CO 2" V. 2 FU FD2 2"(2) CO 2" V. 2 FU FS 2"(2) CO 2" V. 2 FU FS MOP SINK 2"(3) 4"GW(42) 4" CO CO 4"GW(8)4"GW(10)4"GW(13)4"GW(15)4"GW(17)4"GW(20)4"GW(22) 2" V. 3 FU 2" V 3 FU 4"GW(24)4"GW(25) 2" V 5 FU 2" V 8 FU 2" V 10 FU 2" V 12 FU 2" V 15 FU 2" V 17 FU 2" V 19 FU 2" V 20 FU 2" V 23 FU 2" V 25 FU 4"GW(32) 2" V 27 FU 2" V 28 FU CO CO 2% SLOPE 2% SLOPE2% SLOPE (TYP)(TYP)(TYP) 4"GW(5) FS2 2"(1) HS 2" V. 1 FU CO 4"GW(12) MEAT SERVICE FS2 2"(2) CO 2" V. 2 FU 4"GW(2) 2" V 6 FU TORTILLERIA 4"GW(80) FS 2"(2) 2" ( 2 ) 4"GW(9) FS 2"(2) CO 2" V. 2 FU 2" V 2 FU 4"GW(2) 2" V. 2 FU FD 2"(2) CO 2" V 3 FU 2" V 5 FU 4"GW(3) 2"(1) HS 2" V. 1 FU CO 2"(1) HS 2" V. 1 FU CO 2"(1) HS 2" V. 1 FU CO 2" V 1 FU 2" V 3 FU 4"GW(41) 2" V 1 FU 2" V 3 FU 2" V 7 FU 2" V 1 FU 4"GW(19) 4"GW(1) 4" CO 2" V. 2 FU FS 3"(2) FS 3"(2) CO 2" V. 2 FU 2" VTR 4 FU 2" V. 4 FU CO 2" V. 2 FU FS 3"(2) FS 3"(2) 4"(12)4"(14) FS 3"(2) FS 3"(2) 4"(2)4"(4) 2" V 5 FU 2" V 2 FU UR 2"(2) CO 2" V. 2 FU 2"(2) CO FD 2" V. 2 FU 2" V 6 FU 2" V 8 FU 4"SS(4)4"SS(6) HOLD- 420 W 17th St3/7/2025 23XX 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 HOLD- 420 W 17th St3/7/2025 (M) BEER COOLER (N) CHECKSTAND (N) CUSTOMER SERVICE (E) FREEZER (M) TORTILLERIA PREP (N) CHECK CASHING (N) MEAT COOLER(N) MEAT PREP (M) PRODUCE COOLER (N) DAIRY COOLER (N) CREMERIA ISLAND (N) BAKERY & KITCHEN COOLER (N)SAFE ROOM (N)BREAK ROOM (N) MEN RESTROOM (N) WOMEN RESTROOM (N) BAKERY & KITCHEN FREEZER SALES JUICE BAR CONCOURSE (N) HALL/ BACKSTOCK (N) LA COCINA (N) PAN DULCE (N) BAKERY PREP (N) HALL/ BACKSTOCK (E) HALL/ BACKSTOCK (E) HALL/ BACKSTOCK PRODUCE PREP (M) TORTILLERIA SERVICE PRODUCE CL CL So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 2 3 41 A D E F 2 3 41 A D E F BB CC SoloChill Micro Distributed Models: DA091, DA130, DA220 (N) MEAT SERVICE EUIPMENT LEGEND TYPE MANUFACTURER MODEL MEAT PREP MEAT SERVICE BAKERY CREMERIA KITCHEN TORTILLERIA SMOOTHIE BAR JANITOR SALES AREA DAILY COOLER BACKSTOCK 2210 26575 Ruether Ave 2nd floor CH A R C Santa Clarita, CA 91350 661.383.2352 - 818.919.2248 BI G S A V E R F O O D S NO R T H TR U E 1 F1.0 F I X T U R E S P L A N FIXTURES PLAN HOLD- 420 W 17th St3/7/2025 NOTE TO CONTRACTORS: FOR ANY CONSTRUCTION WORK PERFORMED WITH OBSOLETE PLANS. OBTAIN AND USE THE LATEST PLANS. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO ARCTIC COOLING SYSTEMS WILL NOT BE RESPONSIBLE AR C T I C CO O L I N G CL CL So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 09 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 09 1 , D A 1 3 0 , D A 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 09 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 09 1 , D A 1 3 0 , D A 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 HOLD- 420 W 17th St3/7/2025 NOTE TO CONTRACTORS: FOR ANY CONSTRUCTION WORK PERFORMED WITH OBSOLETE PLANS. OBTAIN AND USE THE LATEST PLANS. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO ARCTIC COOLING SYSTEMS WILL NOT BE RESPONSIBLE AR C T I C CO O L I N G SoloChill Micro Distributed Models: DA091, DA130, DA220 HOLD- 420 W 17th St3/7/2025 So l o C h i l l M i c r o D i s t r i b u t e d Mo d e l s : D A 0 9 1 , D A 1 3 0 , DA 2 2 0 SoloChill Micro Distributed Models: DA091, DA130, DA220 NOTE TO CONTRACTORS: FOR ANY CONSTRUCTION WORK PERFORMED WITH OBSOLETE PLANS. OBTAIN AND USE THE LATEST PLANS. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO ARCTIC COOLING SYSTEMS WILL NOT BE RESPONSIBLE AR C T I C CO O L I N G NOTES: HOLD- 420 W 17th St3/7/2025 NOTE TO CONTRACTORS: FOR ANY CONSTRUCTION WORK PERFORMED WITH OBSOLETE PLANS. OBTAIN AND USE THE LATEST PLANS. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO ARCTIC COOLING SYSTEMS WILL NOT BE RESPONSIBLE AR C T I C CO O L I N G SoloChill Micro Distributed Models: DA091, DA130, DA220 HOLD- 420 W 17th St3/7/2025 NOTE TO CONTRACTORS: FOR ANY CONSTRUCTION WORK PERFORMED WITH OBSOLETE PLANS. OBTAIN AND USE THE LATEST PLANS. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO ARCTIC COOLING SYSTEMS WILL NOT BE RESPONSIBLE AR C T I C CO O L I N G SoloChill Micro Distributed Models: DA091, DA130, DA220 E2 MODBUS NETWORK WIRING 4. 9 9 K +5 V +5 V +5 V +1 2 V ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON AC 1 AC 2 0V + 0 V - 1 2 3 4 5 6 7 8 16 1 6 L A O / L D O Ve r . 1 . 0 0 23 7 - 3 0 6 8 WH T # 2 0 ON 1 NC F a i l s a f e NO F a i l s a f e ON OU T P U T S AN A L O G + 1 - 16 + 2 - + 3 - + 4 - CPC PART#810-3073 MULTIFLEX 1616LAO S1-SENSOR TYPE SELECT FOR INPUTS 1-8 POWER(24VAC) RS485 JP2 JP3 JP4 S2-SENSOR TYPE SELECT S3-NETWORK ADDRESS, BAUD FOR INPUTS 9-16 FOR 16AI BOARD S4-NETWORK ADDRESS, BAUD FOR 8RO & 8DO S4 S3 S2 S1 NO NC1 NO 9 NC NO 2 NC NO 3 NC NO 4 NC NO 5 NC NO 6 NC NO 7 NC NO NC8 NO 10 NC 11 NO NC NO 12 NC NO 13 NC NO 14 NC NO 15 NC NO 16 NC Relay # 6 J8(HHT)INPUT1 INPUT2 0V INPUT3 INPUT4 SGSG 0V 0V SG 0V SG 0V SG 0V SG 0V SG SG0V NO 5 NC NO 6 NC INPUT50V SG LOCATED IN CUSTOM DESIGNED CONTROL PANEL 16 Channel Input Board #4 and 8 Channel Relay Board #4 INPUT POINT DEVICE DESCRIPTION CABLE # 5 DI ALARM RESET 3 OUTPUT POINT DEVICE DESCRIPTION CABLE # 4.5 4.6 NC NC ALARM LIGHT ALARM HORN AC2 AC1 0V 24V 24V NEUTRAL 640-0039 (10VA) USE 5 CONDUCTOR CABLE OR THERMOSTAT CABLE PREWIRED 24VAC COMMON WHITE 6 7 HOT 120 VAC NOTES: 1) USE WIRE COLOR CODES AND CABLING AS ILLUSTRATED. 2) CONNECT ALARM SILENCE TO INPUT 5 OF THE MULTIFLEX CONTROLLER BOARD. 3) CONNECT ALARM LIGHT TO OUTPUT 5 OF THE MULTIFLEX CONTROLLER BOARD. 4) CONNECT ALARM HORN TO OUTPUT 6 THE MULTIFLEX CONTROLLER BOARD. MULTIFLEX BOARD WIRING TO ALARM ANNUNCIATOR PANEL CONNECTIONS HORN WHT #20 RESET SW1 LIGHT L1 INPUT5 INPUT6 INPUT7 INPUT8 INPUT9 INPUT10 0V INPUT11 INPUT12 SGSG 0V 0V SG 0V SG 0V SG 0V SG 0V SG SG0V INPUT13 INPUT14INPUT15 INPUT16 HOLD- 420 W 17th St3/7/2025 AR C T I C CO O L I N G HOLD- 420 W 17th St3/7/2025 NOTE TO CONTRACTORS: FOR ANY CONSTRUCTION WORK PERFORMED WITH OBSOLETE PLANS. OBTAIN AND USE THE LATEST PLANS. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO ARCTIC COOLING SYSTEMS WILL NOT BE RESPONSIBLE AR C T I C CO O L I N G SY S T E M S VNRZ Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food / Ice Cream) 37 1/8" [94.3 cm] TOP WIRING REQUIRED LOAD LIMIT 24" [22"] 24" [22"] 24" [22"] 24" [22"] 24" [22"] 24" [22"] 24" [22"] 23 1/8" [58.7 cm] COIL PLENUM 5 3/4" [14.6 cm]* 26 1/2" [67.3 cm] 32 7/8" [83.5 cm] 37 1/8" [94.3 cm] 12" [30.5 cm] 2" MINIMUM AIR GAP WIRING TO THE TOP (12" X 10" X 4") PIPING TO THE TOP (OPTIONAL) REAR REFRIGERATION LOCATED 9 1/4" ABOVE FINISH FLOOR DEFAULT REFRIGERATION 1 1/2" PVC DRAIN CONNECTION 31" [78.7 cm] (1 DOOR) 60" [152.4 cm] (2 DOOR) 90" [228.6 cm] (3 DOOR) 120" [304.8 cm] (4 DOOR) 150" [381.0 cm] (5 DOOR) 5" [12.7 cm] 8 3/4" [22.2 cm] 1 1/2" [3.8 cm] END NOTES * : STUB-UP AREA. ** : RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS. • Ends add approximately 1" to case height, 1/2" to the back & 1" to the front. VNRZ COMPONENT ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS. Rev. Date Rev. # 7-13-20 1-28-20 8 7 Rev. Title DATA UPDATE DATA UPDATE 37 1 / 8 " [ 9 4 . 3 c m ] 32 7 / 8 " [ 8 3 . 5 c m ] 26 1 / 2 " [ 6 7 . 3 c m ] 87 7 / 8 " [ 2 2 3 . 2 c m ] O V E R A L L C A S E H E I G H T 90 1 / 8 " [ 2 2 8 . 9 c m ] S H I P P I N G H E I G H T 83 7 / 8 " [ 2 1 3 . 0 c m ] C A S E H E I G H T 30 1 / 8 " [ 7 6 . 5 c m ] * * 23 1 / 2 " [ 5 9 . 7 c m ] 66 " [ 1 6 7 . 6 c m ] I N T E R I O R H E I G H T 4 1 / 8 " [ 1 0 . 5 c m ] OP T I O N A L P I P N G T O T H E T O P 66 3 / 1 6 " [ 1 6 8 . 1 c m ] V I S U A L D I S P L A Y 8 1 / 4 " [ 2 1 . 0 c m ] 75 " [ 1 9 0 . 5 c m ] F R A M E H E I G H T 73 " [ 1 8 5 . 4 c m ] D O O R H E I G H T 3" [ 7 . 6 c m ] 23 1 / 4 " [ 5 9 . 1 c m ] 5DMLH-NRG WIRING TO THE TOP (OPTIONAL) PIPING TO THE TOP (OPTIONAL) LOAD LIMIT 4', 6', 8' & 12' High Multi-Deck Merchandiser with Synerg-E™ Beverage/Bulk Produce/Bakery/Dairy/Cut Produce/Deli 40 11/16" [103.3 cm] 24 in 24 in 24 in 24 in 24 in 1 30 5/8" [77.8 cm] COIL PLENUM 6 15/16" [17.5 cm]* 31 1/2" [80.0 cm] 39 3/16" [99.5 cm] 41 1/4" [104.8 cm] 42 3/4" [108.6 cm] WIRING TO THE TOP (OPTIONAL) 2" MINIMUM AIR GAP PIPING TO THE TOP (OPTIONAL) 9 1/8" [23.2 cm] ELECTRICAL JUNCTION BOX 1 1/2" [3.8 cm] END 1 1/2" PVC DRAIN CONNECTION NOTES: * : STUB-UP AREA ** : RECOMMENDED STUP-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS 48" [121.9 cm] 72" [182.9 cm] 96" [243.8 cm] 144" [365.8 cm] __ : AVAILABLE SHELF SIZES: 10", 12", 14", 16", 18", 20", 22" & 24"; (5) ROWS OF SHELVES MAX1 • Ends add approximately 1" to case height. • Back panels add approximately 1" to the rear of the case. DEFAULT REFRIGERATION 8 3/4" [22.2 cm] 5DMLH-NRG COMPONENT ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS. Rev. Date Rev. # 8-3-20 9-9-19 6 5 Rev. Title OPTIONS UPDATE ENDVIEW UPDATE 41 1 / 4 " [ 1 0 4 . 8 c m ] 40 1 1 / 1 6 " [ 1 0 3 . 3 c m ] 38 7 / 1 6 " [ 9 7 . 6 c m ] 31 1 / 2 " [ 8 0 . 0 c m ] 85 7 / 8 " [ 2 1 8 . 2 c m ] O V E R A L L C A S E H E I G H T 88 1 / 8 " [ 2 2 3 . 9 c m ] S H I P P I N G H E I G H T 35 5 / 8 " [ 9 0 . 6 c m ] * * 4 1 / 8 " [ 1 0 . 5 c m ] 82 5 / 8 " [ 2 0 9 . 9 c m ] C A S E H E I G H T 64 1 / 2 " [ 1 6 3 . 8 c m ] I N T E R I O R H E I G H T 28 " [ 7 1 . 1 c m ] 60 3 / 4 " [ 1 5 4 . 3 c m ] V I S U A L D I S P L A Y 14 3 / 4 " [ 3 7 . 5 c m ] 28 1 / 8 " [ 7 1 . 4 c m ] 1 1 / 2 " [ 3 . 8 c m ] 42 3 / 4 " [ 1 0 8 . 6 c m ] SLIDING REAR LOAD DOORS 10 1/2 in [26.7 cm] 14 in 24 7/8 in [63.3 cm] [35.6 cm] 16 in [40.6 cm] 52 1/8 in [132.4 cm] 33 5/16 in [84.6 cm] 24 3/4 in [62.9 cm] 23 3/16 in [58.8 cm] 13 15/16 in [35.4 cm] ELECTRICAL RACEWAY 3 5/16 in [8.4 cm] 31 1/2 in [80.0 cm] 42 in [106.7 cm] 12 5/16 in [31.2 cm] POWER SUPPLY 6 in [15.2 cm] 1 5/8 in [4.2 cm] 16 1/8 in [41.0 cm] 31 1/2 in [80.0 cm] 42 in [106.7 cm] 12" x 12" MECHANICAL ACCESS FOR ELECT. ,REFRIG. ,AND DRAIN CONNECTIONS TOEKICK 1 in [2.5 cm]TOEKICK CL FRONT OF CASE 72 1/2 in 48 1/8 in 96 1/4 in 120 1/2 in 144 1/4 in [122.2 cm] 4’ case [184.2 cm] 6’ case [244.5 cm] 8’ case [306.1 cm] 10’ case [366.4 cm] 12’ case 1 in [2.5 cm] *SHOWN WITH OPTIONAL SHELVING 09/17 SMD-R (Remote)SERVICE MULTI-DECK BAKERY/DELI OHMH-NRG High Multi-Deck Merchandiser with Synerg-E™ 4', 6', 8' & 12' (Deli / Meat) 34 7/8" [88.5 cm] OPTIONAL WIRING TO THE TOP 12 in X 10 in X 4 in 9" MIRROR OPTIONAL 9" MIRROR OPTIONAL LOAD LIMIT LOAD LIMIT 1 16 in 18 in 20 in 20 in 32 1/4" [81.9 cm] COIL PLENUM COIL PLENUM 1 16 in 18 in 20 in 20 in 32 1/4" [81.9 cm] 32 5/8" [82.8 cm] 31 3/4" [80.6 cm]6 5/8" [16.8 cm] 39 1/4" [99.7 cm] 43 1/4" [109.9 cm] 11" BASEFRAME WIRING TO THE TOP (OPTIONAL)2" MINIMUM AIR GAP PIPING TO TOP (OPTIONAL) 5" BASEFRAME 12" [30.4 cm] REAR REFRIGERATION LOCATED 8 3/4" ABOVE FINISH FLOOR DEFAULT REFRIGERATION ELECTRICAL JUNCTION BOX 1 1/2" PVC DRAIN CONNECTION NOTES: * ** 1 48" [121.9 cm] 72" [182.9 cm] 96" [248.3 cm] 144" [365.8 cm] : STUB-UP AREA : RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND DRAINS : AVAILABLE SHELF SIZES: 10", 12", 14", 16", 18", 20", 22" & 24" • Ends add approximately 1" to case height, 1/2" to the back & 1" to the front. • Back panels add approximately 1" to the rear of the case. 1 1/2" [3.8 cm] END 8 3/4" [22.2 cm] OHMH-NRG COMPONENT ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS. Rev. Date Rev. # 9-19-18 6-12-18 3 2 Rev. Title DATA UPDATE NEW STANDARDS 43 1 / 4 " [ 1 0 9 . 9 c m ] 5" B A S E F R A M E 39 1 / 4 " [ 9 9 . 7 c m ] 86 7 / 1 6 " [ 2 1 9 . 6 c m ] S H I P P I N G H E I G H T 11 " B A S E F R A M E 32 5 / 8 " [ 8 2 . 9 c m ] 84 3 / 1 6 " [ 2 1 3 . 8 c m ] O V E R A L L C A S E H E I G H T 80 7 / 8 " [ 2 0 5 . 4 c m ] C A S E H E I G H T 53 7 / 8 " [ 1 3 6 . 8 c m ] I N T E R I O R H E I G H T 11 " [ 2 7 . 9 c m ] RE A R P I P E B O X 28 1 / 2 " [ 7 2 . 4 c m ] * 22 3 / 4 " [ 5 7 . 8 c m ] 27 " [ 6 8 . 6 c m ] 15 1 3 / 1 6 " [ 4 0 . 2 c m ] * * 11 " B A S E F R A M E 78 5 / 1 6 " [ 1 9 8 . 9 c m ] O V E R A L L C A S E H E I G H T 80 9 / 1 6 " [ 2 0 4 . 6 c m ] S H I P P I N G H E I G H T 34 1 5 / 1 6 " [ 8 8 . 7 c m ] * * 5" B A S E F R A M E 5 1 / 8 " [ 1 3 . 0 c m ] RE A R P I P E B O X 74 5 / 1 6 " [ 1 8 8 . 8 c m ] C A S E H E I G H T 46 7 / 8 " [ 1 1 9 . 1 c m ] V I S U A L D I S P L A Y 3" [ 7 . 6 c m ] 28 5 / 8 " [ 7 2 . 7 c m ] 16 7 / 8 " [ 4 2 . 9 c m ] 21 1 / 8 " [ 5 3 . 7 c m ] 15 3/4 in [40.0 cm] LOAD LIMIT LINE 10 in [25.4 cm] 30 7/8 in [78.4 cm] 50 7/8 in [129.2 cm] 25 7/8 in [65.8 cm] 17 1/2 in [44.5 cm] 6 5/16 in [16.0 cm] 1 1/2 in [3.7 cm] 28 5/8 in [72.7 cm] 37 5/8 in [95.6 cm] 14 in [35.6 cm] 13 13/16 in [35.0 cm] POWER SUPPLY 6 in [15.2 cm] 1 1/2 in [3.8 cm] 15 1/16 in [38.2 cm] 28 5/8 in [72.7 cm] 37 5/8 in [95.6 cm] 15" x 13" MECHANICAL ACCESS FOR ELECT. ,REFRIG. ,AND DRAIN CONNECTIONS TOEKICK 1 in [2.5 cm] CL FRONT OF CASE 48 1/2 in[123.2 cm] 48” case 56 1/2 in[143.5 cm] 59” case 74 5/8 in[189.5 cm] 77” case 120 1/2 in[306.1 cm] 120” case 96 1/2 in [245.1 cm] 96” case 130 1/2 in[331.5 cm] 132” case 144 1/2 in[367.0 cm] 144” case TOEKICK 1 in [2.5 cm] 09/17 BLF-SR (Remote) SERVICE MULTI-DECK Bakery VNRB Narrow Reach-In Merchandiser 2, 3, 4, & 5 Door / 4', 6, 8' & 12' (Beverage / Dairy / Deli / Meat) 33 3/4" [85.7 cm] TOP WIRING REQUIRED LOAD LIMIT 24" 24" 24" 24" 24" 24" 24" [22"] [22"] [22"] [22"] [22"] [22"] [22"] 23 1/8" [58.7 cm] COIL PLENUM 5 3/4" [14.6 cm] 26 1/2" [67.3 cm] 32 7/8" [83.5 cm] 37 1/8" [94.3 cm] 12" [30.5 cm] REAR WIRING TO THE TOP (12" X 10" X 4") 2" AIR GAP REQUIRED PIPING TO THE TOP (OPTIONAL) REFRIGERATION LOCATED 9 1/4" ABOVE FINISH FLOOR DEFAULT REFRIGERATION ELECTRICAL JUNCTION BOX (WIRING PER LOCAL CODES) 1 1/2" PVC DRAIN CONNECTION 48" [121.9 cm] (4') 72" [182.9 cm] (6') 96" [243.8 cm] (8') 60" [152.4 cm] (2 DOOR) 90" [228.6 cm] (3 DOOR) 120" [304.8 cm] (4 DOOR) 144" [365.8 cm] (12') 150" [381.0 cm] (5 DOOR) NOTES * : STUB-UP AREA ** : RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS. • Ends add approximately 1" to case height, 1/2" to the back & 1" to the front. 8 3/4" [22.3 cm] 1 1/2" [3.8 cm] END VNRB COMPONENT ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72- 2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS. Rev Date: 4-25-18 12-1-17 Rev # 2 1 Revision Description: NEW STANDARDS DOE 2017 37 1 / 8 " [ 9 4 . 3 c m ] 32 7 / 8 " [ 8 3 . 5 c m ] 26 1 / 2 " [ 6 7 . 3 c m ] 90 5 / 8 " [ 2 3 0 . 2 c m ] S H I P P I N G H E I G H T 87 7 / 8 " [ 2 2 3 . 2 c m ] O V E R A L L C A S E H E I G H T 2" [ 5 . 1 c m ] 4 1 / 8 " [ 1 0 . 5 c m ] 30 1 / 8 " [ 7 6 . 5 c m ] * * 83 7 / 8 " [ 2 1 3 . 0 c m ] C A S E H E I G H T 66 " [ 1 6 7 . 7 c m ] I N T E R I O R H E I G H T 23 1 / 2 " [ 5 9 . 7 c m ] * 66 5 / 8 " [ 1 6 9 . 2 c m ] V I S U A L D I S P L A Y 8 1 / 4 " [ 2 1 . 0 c m ] 73 " [ 1 8 5 . 4 c m ] D O O R H E I G H T 75 " [ 1 9 0 . 5 c m ] F R A M E H E I G H T 3" [ 7 . 6 c m ] 7" [ 1 7 . 8 c m ] 23 1 / 4 " [ 5 9 . 0 c m ] OHPH-NRG High Multi-Deck Merchandiser with Synerg-E™ 4', 6', 8' & 12' (Produce) OPTIONAL WIRING TO THE TOP 12 in X 10 in X 4 in 9" MIRROR OPTIONAL LOAD LIMIT 16 in 18 in 20 in 20 in 1 32 1/4" [81.9 cm] COIL PLENUM 34 3/4" [88.2 cm] 32 5/8" [82.9 cm] 31 3/4" [80.6 cm] 28 1/8" [71.4 cm] 43 1/4" [109.9 cm] 11" BASEFRAME WIRING TO THE TOP (OPTIONAL) 2" MINIMUM AIR GAP PIPING TO THE TOP (OPTIONAL)12" [30.5 cm] REAR REFRIGERATION LOCATED 11 1/4" ABOVE FINISH FLOOR DEFAULT REFRIGERATION ELECTRICAL JUNCTION BOX 1 1/2" PVC DRAIN CONNECTION 1 1/2" [3.8 cm] END NOTES: 48" [121.9 cm] 72" [182.9 cm] 96" [243.8 cm] 144" [365.8 cm] * : STUB-UP AREA ** : RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND DRAINS :AVAILABLE SHELF SIZES: 10", 12", 14", 16", 18" & 20"1 • Ends add approximately 1" to case height, 1/2" to the back & 1" to the front. • Back panels add approximaely 1" to the rear of the case. COMPONENT ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS. Rev Date: 10/16/18 6/1/18 Rev # 3 2 OHPH-NRG Revision Description: DATA UPDATE NEW STANDARDS 8 3/4" [22.2 cm] 43 1 / 4 " [ 1 0 9 . 8 c m ] 86 5 / 1 6 " [ 2 1 9 . 3 c m ] S H I P P I N G H E I G H T 11 " B A S E F R A M E 32 5 / 8 " [ 8 2 . 9 c m ] 11 " [ 2 7 . 9 c m ] RE A R P I P E B O X 84 3 / 1 6 " [ 2 1 3 . 9 c m ] O V E R A L L C A S E H E I G H T 80 7 / 8 " [ 2 0 5 . 4 c m ] C A S E H E I G H T 52 1 / 4 " [ 1 3 2 . 7 c m ] I N T E R I O R H E I G H T 22 3 / 4 " [ 5 7 . 8 c m ] 46 7 / 8 " [ 1 1 9 . 1 c m ] V I S U A L D I S P L A Y 27 " [ 6 8 . 6 c m ] 28 1 / 2 " [ 7 2 . 4 c m ] * 11 " B A S E F R A M E 13 1 / 4 " [ 3 3 . 6 c m ] * * 28 5 / 8 " [ 7 2 . 7 c m ] 3" [ 7 . 6 c m ] OIP Wide Single-Deck Island Merchandiser 8' & 12' (Bulk Produce) 5" [12.9 cm] LOAD LIMIT 31 1/2" [79.9 cm] PLENUM COIL COIL PLENUM 43 7/8" [111.4 cm]* 21 7/8" [55.7 cm] 24 1/2" [62.2 cm] 40" [101.5 cm] 79 7/8" [202.9 cm] 41 7/8" [106.3 cm] DEFAULT REFRIGERATION 15 7/16" [39.2 cm] 18" [45.7 cm] 69 5/8" [176.8 cm]* 117 5/8" [298.8 cm]* ELECTRICAL JUNCTION BOX 1 1/2" PVC DRAIN CONNECTION 52 13/16" [134.1 cm] 76 13/16" [195.1 cm] 105 5/8" [268.3 cm] 153 5/8" [390.2 cm] NOTES *: STUB-UP AREA • Front and center sill heights vary with base frame height. OIP COMPONENT ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS. Rev Date: 7-17-18 12-1-17 Rev # 2 1 Revision Description: NEW STANDARDS DOE 2017 79 7 / 8 " [ 2 0 2 . 9 c m ] 39 1 5 / 1 6 " [ 1 0 1 . 4 c m ] 20 1 1 / 1 6 " [ 5 2 . 5 c m ] 21 1 5 / 1 6 " [ 5 5 . 7 c m ] 24 1 / 2 " [ 6 2 . 2 c m ] 47 5 / 1 6 " [ 1 2 0 . 2 c m ] S H I P P I N G H E I G H T 45 1 / 8 " [ 1 1 4 . 5 c m ] C A S E H E I G H T IN T E R I O R H E I G H T 20 1 / 8 " [ 5 1 . 1 c m ] 43 7 / 8 " [ 1 1 1 . 4 c m ] * 14 3 / 4 " [ 3 7 . 5 c m ] 27 1 / 4 " [ 6 9 . 1 c m ] 23 " [ 5 8 . 5 c m ] THR O A T D I S P L A Y 35 1 5 / 1 6 " [ 9 1 . 4 c m ] HOLD- 420 W 17th St3/7/2025 NOTE TO CONTRACTORS: FOR ANY CONSTRUCTION WORK PERFORMED WITH OBSOLETE PLANS. OBTAIN AND USE THE LATEST PLANS. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO ARCTIC COOLING SYSTEMS WILL NOT BE RESPONSIBLE AR C T I C CO O L I N G SY S T E M S PF-5R EC i2i DRAWING # 146598 The refrigeration spec for this case is CO2 ENGINEERED FOR STORES WITH AMBIENT CONDITIONS NOT TO EXCEED 75° AND 55% RELATIVE HUMIDITY. DUE TO ENGINEERING IMPROVEMENTS SPECIFICATIONS MAY CHANGE WITHOUT NOTICE. ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS. NUMBERS ARE BASED ON STANDARD CASE SIZES. CONSULT ENGINEERING. PFI-506R IC DRAWING # 146599 The refrigeration spec for this case is CO2 ENGINEERED FOR STORES WITH AMBIENT CONDITIONS NOT TO EXCEED 75° AND 55% RELATIVE HUMIDITY. DUE TO ENGINEERING IMPROVEMENTS SPECIFICATIONS MAY CHANGE WITHOUT NOTICE. ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS. NUMBERS ARE BASED ON STANDARD CASE SIZES. CONSULT ENGINEERING. FT-12R DRAWING # 146602 The refrigeration spec for this case is CO2 ENGINEERED FOR STORES WITH AMBIENT CONDITIONS NOT TO EXCEED 75° AND 55% RELATIVE HUMIDITY. DUE TO ENGINEERING IMPROVEMENTS SPECIFICATIONS MAY CHANGE WITHOUT NOTICE. ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS. NUMBERS ARE BASED ON STANDARD CASE SIZES. CONSULT ENGINEERING. HOLD- 420 W 17th St3/7/2025 NOTE TO CONTRACTORS: FOR ANY CONSTRUCTION WORK PERFORMED WITH OBSOLETE PLANS. OBTAIN AND USE THE LATEST PLANS. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO ARCTIC COOLING SYSTEMS WILL NOT BE RESPONSIBLE AR C T I C CO O L I N G DWG Version 1.1Data Version 0.00 BALTIMORE AIRCOIL COMPANY TW-Q14030568602 TrilliumSeries™ Condenser Customer Wiring Q14030568602 5/7/2014 Shipping/Rigging Weight Operating Weight Model Number 42883936TSDC-CO2-154-12.4 PIPING SHOWN HERE JUST FOR REFERENCEONLY. REFER TO MECH DRAWING FOR PIPING AND COMPONENTS. RESERVOIR RACEWAY 3'-0" TOP VIEWAHR IN/OUTRECEIVER LT ACCUMULATOR DOS UPS VFD CONTROLLER MT SUCTION 6'-7 5/16" CONTROLLER 5'-10" LT SUCTION CONTROL PANEL 60W X 74H LIQUID SUPPLY 11 5/16" 15'-11" 17'-2" 17'-9 1/2" FRONT VIEW NOTE: 1. ESTIMATED APPROXIMATE DRY SHIPPING WEIGHT: 9000 LBS2. USE ALL LIFTING LUGS FOR CUSTOMER USE ONLYDO NOT USE FOR CONSTRUCTION Hillphoenix Inc. CONFIDENTIAL The information set forth in this document is confidential and proprietary. No reproduction or dissemination of thisinformation is authorized by Hillphoenix or it's agents. This document is to be distributed only to recipients authorized by Hillphoenix. This document is to be returned to Hillphoenix upon completion of it's use by the authorized recipient or upon request by Hillphoenix. Ⓒ Copyright 2022-2023 Hillphoenix, Inc. A Dover Company Conyers, Georgia, USA SIDE VIEW 5'-0" CO N T R O L PA N E L 11 3' - 0 " RESERVOIR RACEWAY CO N T R O L PA N E L RESERVOIR RACEWAY CO N T R O L PA N E L HOLD- 420 W 17th St3/7/2025 STRUCTURAL CALCULATIONS FOR BIG SAVERS REMODEL 420 W 17th St Santa Ana,CA 92706 BY GEORGE KILEDJIAN 818-635-1691 GKSTR@YAHOO.COM HOLD- 420 W 17th St3/7/2025 1 LOAD CRITERIA ROOF:CEILING: ROOFING 4.0 psf FINISH 5.0 psf FRAMING 4.0 psf FRAMING 3.0 psf INSULATION 1.0 psf MISC 2.0 psf CEILING 3.0 psf DL =10.0 psf MEP 2.0 psf LL =10.0 psf MISC 1.0 psf DL =15.0 psf Lr =20.0 psf CURTAIN WALL: FINISH 5.0 psf FRAMING 3.0 psf MISC 2.0 psf DL =10.0 psf SITE SPECIFIC SEISMIC FACTORS: Ss =2.12 g Sds =1.70 g S1 =0.77 g WIND: Given: V =90 mph Kzt =1.00 Kz =0.94 Kd =0.85 qz = 0.00256 * Kz * Kzt * Kd * V ^ 2 qz =0.00256 *0.94 *1.00 *0.85 *90 ^2 qz =16.6 psf p = qp * (GCp - GCpi) pA1 =16.6 * (1.00 -0.00 ) =16.6 psf [Wall zone 4, pos press] pA2 =16.6 * (-1.70 -0.00 ) =-28.2 psf [Roof zone 2, neg press] pB1 = pA1 =16.6 psf [Wall zone 4, pos press] pB2 =16.6 * (-1.10 -0.00 ) =-18.2 psf [Wall zone 4, neg press] pA = pA1 - pA2 =16.6 --28.2 =44.7 psf GOVERNS pB = pB1 - pB2 =16.6 --18.2 =34.8 psf p =44.7 psf HOLD- 420 W 17th St3/7/2025 2 RTU ANCHORAGE [CRITICAL CASE]: L =6.5 ft Sds =1.70 g z / h =1.0 B =4.5 ft ap = 2.5 H =3.0 ft Rp =6.0 Wp =1.50 kip Ip =1.0 SEISMIC COEFFICIENT: Fp = 0.4 * ap * Sds * Wp / (Rp / Ip) * (1 + 2 * z/h) Fp =0.4 *2.5 *1.7 / (6.0 /1.0 )*(1 +2 *1.0 ) * Wp Fp =0.85 * Wp Fp min = 0.3 * Sds * Ip * Wp =0.3 *1.7 *1.0 * Wp =0.51 * Wp Fp max = 1.6 * Sds * Ip * Wp =1.6 *1.7 *1.0 * Wp =2.72 * Wp Fp =0.85 * Wp SLIDING CHECK: P EL = Fp * Wp =0.85 *1.5 =1.28 kip TRY:4-1/4" SDS SCREWS AT PLATFORM [V allow =0.25 kip, n =4 , CD =1.33 ] P allow = CD * V allow * n =1.33 *0.25 *4 =1.33 kip >1.28 kip USE AT PLATFORM:4-1/4" SDS SCREWS AT PLATFORM OVERTURNING CHECK: M EL = P EL * H / 2 + 0.2 * Sds * Wp * B / 2 M EL =1.28 *3.0 /2 +0.2 *1.70 *1.50 *4.50 /2 M EL =3.06 ft-K RM = Wp * B / 2 =1.50 *4.5 /2 =3.38 ft-K T reqd = (0.7 / 0.6 * M EL - RM) / (B - 0.5) T reqd = (0.7 /0.6 *3.06 -3.38 )/(4.5 -0.5 ) =0.05 kip TRY:4-1/4" SDS SCREWS AT PLATFORM [T allow =0.60 kip, n =2 , CD =1.33 ] T = CD * T allow * n =1.33 *0.6 *2 =1.6 kip >0.05 kip USE AT PLATFORM:4-1/4" SDS SCREWS AT PLATFORM HOLD- 420 W 17th St3/7/2025 3 MAU ANCHORAGE [CRITICAL CASE]: L =3.5 ft Sds =1.70 g z / h =1.0 B =3.5 ft ap = 2.5 H =3.0 ft Rp =6.0 Wp =0.80 kip Ip =1.0 SEISMIC COEFFICIENT: Fp = 0.4 * ap * Sds * Wp / (Rp / Ip) * (1 + 2 * z/h) Fp =0.4 *2.5 *1.7 / (6.0 /1.0 )*(1 +2 *1.0 ) * Wp Fp =0.85 * Wp Fp min = 0.3 * Sds * Ip * Wp =0.3 *1.7 *1.0 * Wp =0.51 * Wp Fp max = 1.6 * Sds * Ip * Wp =1.6 *1.7 *1.0 * Wp =2.72 * Wp Fp =0.85 * Wp SLIDING CHECK: P EL = Fp * Wp =0.85 *0.8 =0.68 kip TRY:4-1/4" SDS SCREWS AT PLATFORM [V allow =0.25 kip, n =4 , CD =1.33 ] P allow = CD * V allow * n =1.33 *0.25 *4 =1.33 kip >0.68 kip USE AT PLATFORM:4-1/4" SDS SCREWS AT PLATFORM OVERTURNING CHECK: M EL = P EL * H / 2 + 0.2 * Sds * Wp * B / 2 M EL =0.68 *3.0 /2 +0.2 *1.70 *0.80 *3.50 /2 M EL =1.50 ft-K RM = Wp * B / 2 =0.80 *3.5 /2 =1.40 ft-K T reqd = (0.7 / 0.6 * M EL - RM) / (B - 0.5) T reqd = (0.7 /0.6 *1.50 -1.40 )/(3.5 -0.5 ) =0.12 kip TRY:4-1/4" SDS SCREWS AT PLATFORM [T allow =0.60 kip, n =2 , CD =1.33 ] T = CD * T allow * n =1.33 *0.6 *2 =1.6 kip >0.12 kip USE AT PLATFORM:4-1/4" SDS SCREWS AT PLATFORM HOLD- 420 W 17th St3/7/2025 4 CONDENSING UNIT ANCHORAGE: L =5.3 ft Sds =1.70 g z / h =1.0 B =5.0 ft ap = 2.5 H =3.0 ft Rp =6.0 Wp =1.20 kip Ip =1.0 SEISMIC COEFFICIENT: Fp = 0.4 * ap * Sds * Wp / (Rp / Ip) * (1 + 2 * z/h) Fp =0.4 *2.5 *1.7 / (6.0 /1.0 )*(1 +2 *1.0 ) * Wp Fp =0.85 * Wp Fp min = 0.3 * Sds * Ip * Wp =0.3 *1.7 *1.0 * Wp =0.51 * Wp Fp max = 1.6 * Sds * Ip * Wp =1.6 *1.7 *1.0 * Wp =2.72 * Wp Fp =0.85 * Wp SLIDING CHECK: P EL = Fp * Wp =0.85 *1.2 =1.02 kip TRY:4-1/4" SDS SCREWS AT PLATFORM [V allow =0.25 kip, n =4 , CD =1.33 ] P allow = CD * V allow * n =1.33 *0.25 *4 =1.33 kip >1.02 kip USE AT PLATFORM:4-1/4" SDS SCREWS AT PLATFORM OVERTURNING CHECK: M EL = P EL * H / 2 + 0.2 * Sds * Wp * B / 2 M EL =1.02 *3.0 /2 +0.2 *1.70 *1.20 *5.00 /2 M EL =2.55 ft-K RM = Wp * B / 2 =1.20 *5.0 /2 =3.00 ft-K T reqd = (0.7 / 0.6 * M EL - RM) / (B - 0.5) T reqd = (0.7 /0.6 *2.55 -3.00 )/(5.0 -0.5 ) =-0.01 kip TRY:4-1/4" SDS SCREWS AT PLATFORM [T allow =0.60 kip, n =2 , CD =1.33 ] T = CD * T allow * n =1.33 *0.6 *2 =1.6 kip >-0.01 kip USE AT PLATFORM:4-1/4" SDS SCREWS AT PLATFORM HOLD- 420 W 17th St3/7/2025 5 AHU ANCHORAGE: L =17.5 ft Sds =1.70 g z / h =1.0 B =8.0 ft ap = 2.5 H =5.0 ft Rp =6.0 Wp =6.50 kip Ip =1.0 SEISMIC COEFFICIENT: Fp = 0.4 * ap * Sds * Wp / (Rp / Ip) * (1 + 2 * z/h) Fp =0.4 *2.5 *1.7 / (6.0 /1.0 )*(1 +2 *1.0 ) * Wp Fp =0.85 * Wp Fp min = 0.3 * Sds * Ip * Wp =0.3 *1.7 *1.0 * Wp =0.51 * Wp Fp max = 1.6 * Sds * Ip * Wp =1.6 *1.7 *1.0 * Wp =2.72 * Wp Fp =0.85 * Wp SLIDING CHECK: P EL = Fp * Wp =0.85 *6.5 =5.53 kip TRY:22-1/4" SDS SCREWS AT PLATFORM [V allow =0.25 kip, n =22 , CD =1.33 ] P allow = CD * V allow * n =1.33 *0.25 *22 =7.32 kip >5.53 kip USE AT PLATFORM:22-1/4" SDS SCREWS AT PLATFORM OVERTURNING CHECK: M EL = P EL * H / 2 + 0.2 * Sds * Wp * B / 2 M EL =5.53 *5.0 /2 +0.2 *1.70 *6.50 *8.00 /2 M EL =22.7 ft-K RM = Wp * B / 2 =6.50 *8.0 /2 =26.0 ft-K T reqd = (0.7 / 0.6 * M EL - RM) / (B - 0.5) T reqd = (0.7 /0.6 *22.65 -26.00 )/(8.0 -0.5 ) =0.06 kip TRY:22-1/4" SDS SCREWS AT PLATFORM [T allow =0.60 kip, n =11 , CD =1.33 ] T = CD * T allow * n =1.33 *0.6 *11 =8.8 kip >0.06 kip USE AT PLATFORM:22-1/4" SDS SCREWS AT PLATFORM HOLD- 420 W 17th St3/7/2025 6 HOOD ANCHORAGE: L =11.0 ft Sds =1.70 g z / h =1.0 B =6.5 ft ap = 2.5 H =4.0 ft Rp =6.0 Wp =0.60 kip Ip =1.0 SEISMIC COEFFICIENT: Fp = 0.4 * ap * Sds * Wp / (Rp / Ip) * (1 + 2 * z/h) Fp =0.4 *2.5 *1.7 / (6.0 /1.0 )*(1 +2 *1.0 ) * Wp Fp =0.85 * Wp Fp min = 0.3 * Sds * Ip * Wp =0.3 *1.7 *1.0 * Wp =0.51 * Wp Fp max = 1.6 * Sds * Ip * Wp =1.6 *1.7 *1.0 * Wp =2.72 * Wp Fp =0.85 * Wp SWAY BRACE: P EL = Fp * Wp =0.85 *0.6 =0.51 kip T = P EL / 2 * 2 ^ 0.5 =0.5 /2 *2 ^0.5 =0.36 kip TRY:1/8" SWAY BRACE [As =0.012 sq in, Fy =36.0 ksi, FOS =1.67 ] 5/8" THRU-BOLT [Z perp =0.31 kip, CD =1.33 ] T allow = As * Fy / FOS =0.012 *36.0 /1.67 =0.26 kip >0.36 kip V allow = CD * Z perp =1.33 *0.31 =0.41 kip >0.36 kip USE 1/8" SWAY BRACE 5/8" THRU-BOLT VERT SUPPORT: T DL = Wp / 4 =0.60 /4 =0.15 kip TRY:3/4" THRU-BOLT (4x)[Z perp =0.68 kip, CD =1.33 ] 1/2" VERT ROD [As =0.19 sq in, Fy =36.0 ksi, FOS =1.67 ] V allow = CD * Z perp =1.33 *0.68 =0.90 kip >0.15 kip T allow = As * Fy / FOS =0.190 *36.0 /1.67 =4.10 kip >0.15 kip USE 3/4" THRU-BOLT (4x) 1/2" VERT ROD HOLD- 420 W 17th St3/7/2025 7 FRAMING [ON SCHEMATIC PLAN, THE CRITICAL CASE ARE THE ONES WITH *] M1: Given: L =17.0 ft DLr =15.0 psf W =1.50 kip TW =3.0 ft Lr =20.0 psf w DL = DLr * TW =15 /1000 *3.0 =0.045 klf w Lr = Lr * TW =20 /1000 *3.0 =0.060 klf P DL = W / 2 =1.5 /2 =0.75 kip X =8.5 ft USE GRADE:DFL #2 SIZE:6x12 [See Enercalc] M2: Given: L =17.0 ft DLr =15.0 psf W =6.50 kip TW =5.0 ft Lr =20.0 psf w DL = DLr * TW =15 /1000 *5.0 =0.075 klf w Lr = Lr * TW =20 /1000 *5.0 =0.100 klf P DL = W / 4 =6.5 /4 =1.63 kip X =8.5 ft USE GRADE:PSL 2.2E SIZE:3 1/2x14 [See Enercalc] M3: Given: L =17.0 ft DLr =15.0 psf DLw =10.0 psf TW =1.33 ft Lr =20.0 psf TW2 =5.0 ft DL =10.0 psf H =8.0 ft LL =10.0 psf w DL = DLr * TW + DL * TW2 + DLw * H w DL = (15 *1.33 +10 *5.0 +10 *8.0 ) /1000 w DL =0.15 klf w Lr = Lr * TW =20 /1000 *1.33 =0.027 klf w LL = LL * TW2 =10 /1000 *5.0 =0.050 klf HOLD- 420 W 17th St3/7/2025 8 USE GRADE:DFL #2 SIZE:6x12 [See Enercalc] M4: Given: L =22.0 ft DLr =15.0 psf DLw =10.0 psf TW =2.00 ft Lr =20.0 psf W =1.5 kip TW2 =8.5 ft DL =10.0 psf W2 =0.4 kip H =8.0 ft LL =10.0 psf w DL = DLr * TW + DL * TW2 + DLw * H w DL = (15 *2.00 +10 *8.5 +10 *8.0 ) /1000 w DL =0.20 klf w Lr = Lr * TW =20 /1000 *2.00 =0.040 klf w LL = LL * TW2 =10 /1000 *8.5 =0.085 klf P1 DL = W / 2=1.5 /2 =0.75 kip X = 4 ft P2 DL = W2 /2=0.4 /2 =0.20 kip X = 18 ft USE GRADE:PSL 2.2E SIZE:3 1/2x14 [See Enercalc] M5: Given: L =22.0 ft DLr =15.0 psf DL =10.0 psf TW =2.00 ft Lr =20.0 psf LL =10.0 psf TW2 =7.5 ft w DL = DLr * TW + DL * TW2 w DL = (15 *2.00 +10 *7.5 ) /1000 w DL =0.11 klf w Lr = Lr * TW =20 /1000 *2.00 =0.040 klf w LL = LL * TW2 =10 /1000 *7.5 =0.075 klf USE GRADE:PSL 2.2E SIZE:3 1/2x14 [See Enercalc] HOLD- 420 W 17th St3/7/2025 9 M6: Given: L =17.0 ft DLr =15.0 psf DL =10.0 psf TW =2.00 ft Lr =20.0 psf LL =10.0 psf TW2 =8.0 ft w DL = DLr * TW + DL * TW2 w DL = (15 *2.00 +10 *8.0 ) /1000 w DL =0.11 klf w Lr = Lr * TW =20 /1000 *2.00 =0.040 klf w LL = LL * TW2 =10 /1000 *8.0 =0.080 klf USE GRADE:PSL 2.2E SIZE:3 1/2x14 [See Enercalc] M7 [ROOF PENETRATION HEADOUT]: Given: L =17.0 ft DLr =15.0 psf TW =3.50 ft Lr =20.0 psf w DL = DLr * TW =15 /1000 *3.50 =0.053 klf w Lr = Lr * TW =20 /1000 *3.50 =0.070 klf REINF W/ 1 3/4x11 1/4 MICROLLAM [See Enercalc] M8 [SCREEN WALL SIDING]: Given: H1 =8.0 ft p =44.7 psf TW =0.5 ft w WL = p * TW =44.7 /1000 *0.5 =0.022 klf USE Please note that design is performed assuming composite GRADE:DFL #2 siding to be used has a capacity exceeding a 2x6 FLAT. SIZE:2X6 FLAT [See Enercalc] HOLD- 420 W 17th St3/7/2025 10 M9 [SCREEN WALL POST DESIGN]: Given: H1 =5.5 ft p =44.7 psf H2 =2.5 ft TW =8.0 ft w WL = p * TW =44.7 /1000 *8.0 =0.36 klf USE HSS3x3x5/16 [See Enercalc] M10 [SCREEN WALL BRACE]: Given: H =8.0 ft TW2 =6.0 ft TW =8.0 ft p =44.7 psf P WL = p * TW * TW2 =44.7 /1000 *8.0 *6.0 =2.1 kip USE HSS3x3x5/16 [See Enercalc] M11 [WOOD BEAM AT SCREEN WALL]: Given: L =16.0 ft DLr =15.0 psf TW =2.0 ft Lr =20.0 psf P' WL =2.1 kip w DL = DLr * TW =15.0 /1000 *2.0 =0.030 klf w Lr = Lr * TW =20.0 /1000 *2.0 =0.040 klf P WL = P' WL =2.1 kip X = 8 ft USE GRADE:DFL #2 SIZE:4x12 [See Enercalc] HOLD- 420 W 17th St3/7/2025 11 M12 [WOOD BEAM AT SCREEN WALL]: Given: L =22.0 ft DLr =15.0 psf TW =2.0 ft Lr =20.0 psf P' WL =2.1 kip w DL = DLr * TW =15.0 /1000 *2.0 =0.030 klf w Lr = Lr * TW =20.0 /1000 *2.0 =0.040 klf P WL = P' WL =2.1 kip X = 5, 12 ft USE GRADE:PSL 2.2E SIZE:5 1/4x14 [See Enercalc] HOLD- 420 W 17th St3/7/2025                     !"#$%&'()**+*,-. / 01 23 4 56 78 9 :; <= >? @ AB CD E FG HI JK LM N OP Q RS T U VW W X YZ [ \ HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.03.01 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M1 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 875 875 600 625 1300 470 170 425 31.21 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0450, Lr = 0.060 , Tributary Width = 1.0 ft Point Load : D = 0.750 k @ 8.50 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.632: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 8.500ft 27.74 psi= = 1,093.75psi 6x12Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 212.50 psi== Section used for this span 6x12 Maximum Shear Stress Ratio 0.131 : 1 0.000 ft= = 690.98psi Maximum Deflection 0 <360 557 Ratio =0 <180 Max Downward Transient Deflection 0.125 in 1630Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.366 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 17.0 ft 1 0.605 0.111 0.90 1.000 1.001.00 1.00 4.81 476.4 787.5 0.72 153.01.00 17.01.00 1.00+D+Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 17.0 ft 1 0.632 0.131 1.25 1.000 1.001.00 1.00 6.98 691.0 1,093.8 1.17 212.51.00 27.71.00 1.00+D+0.750Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 17.0 ft 1 0.583 0.118 1.25 1.000 1.001.00 1.00 6.44 637.3 1,093.8 1.06 212.51.00 25.01.00 1.00+0.60D 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 17.0 ft 1 0.204 0.037 1.60 1.000 1.001.00 1.00 2.89 285.9 1,400.0 0.43 272.01.00 10.21.00 . HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.03.01 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M1 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.3662 8.562 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.268 1.268 Max Upward from Load Combinations 1.268 1.268 Max Upward from Load Cases 0.758 0.758 D Only 0.758 0.758 +D+Lr 1.268 1.268 +D+0.750Lr 1.140 1.140 +0.60D 0.455 0.455 Lr Only 0.510 0.510 HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.03.01 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M2 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.2E 2900 2900 2900 750 2200 1118.19 290 2025 45.07 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0750, Lr = 0.10 , Tributary Width = 1.0 ft Point Load : D = 1.630 k @ 8.50 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.394: 1 Load Combination D Only Span # where maximum occurs Span # 1 Location of maximum on span 8.500ft 64.50 psi= = 2,565.72psi 3.5x14.0Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 362.50 psi== Section used for this span 3.5x14.0 Maximum Shear Stress Ratio 0.178 : 1 0.000 ft= = 1,011.45psi Maximum Deflection 0 <360 578 Ratio =0 <180 Max Downward Transient Deflection 0.107 in 1900Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.352 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 17.0 ft 1 0.394 0.161 0.90 0.983 1.001.00 1.00 9.64 1,011.5 2,565.7 1.37 261.01.00 41.91.00 1.00+D+Lr 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 17.0 ft 1 0.390 0.178 1.25 0.983 1.001.00 1.00 13.25 1,390.6 3,563.5 2.11 362.51.00 64.51.00 1.00+D+0.750Lr 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 17.0 ft 1 0.364 0.162 1.25 0.983 1.001.00 1.00 12.35 1,295.8 3,563.5 1.92 362.51.00 58.91.00 1.00+0.60D 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 17.0 ft 1 0.133 0.054 1.60 0.983 1.001.00 1.00 5.78 606.9 4,561.3 0.82 464.01.00 25.11.00 . HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.03.01 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M2 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.3525 8.562 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 2.303 2.303 Max Upward from Load Combinations 2.303 2.303 Max Upward from Load Cases 1.453 1.453 D Only 1.453 1.453 +D+Lr 2.303 2.303 +D+0.750Lr 2.090 2.090 +0.60D 0.872 0.872 Lr Only 0.850 0.850 HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.03.01 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M3 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-05 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 875 875 600 625 1300 470 170 425 31.21 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-05 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.150, Lr = 0.0270, L = 0.050 , Tributary Width = 1.0 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.817: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 8.500ft 35.90 psi= = 875.00psi 6x12Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 170.00 psi== Section used for this span 6x12 Maximum Shear Stress Ratio 0.211 : 1 0.000 ft= = 715.17psi Maximum Deflection 0 <360 470 Ratio =0 <180 Max Downward Transient Deflection 0.104 in 1956Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.433 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+0.750Lr+0.750L n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 17.0 ft 1 0.681 0.176 0.90 1.000 1.001.00 1.00 5.42 536.4 787.5 1.14 153.01.00 26.91.00 1.00+D+L 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 17.0 ft 1 0.817 0.211 1.00 1.000 1.001.00 1.00 7.23 715.2 875.0 1.51 170.01.00 35.91.00 1.00+D+Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 17.0 ft 1 0.579 0.150 1.25 1.000 1.001.00 1.00 6.39 632.9 1,093.8 1.34 212.51.00 31.81.00 1.00+D+0.750Lr+0.750L 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 17.0 ft 1 0.679 0.175 1.25 1.000 1.001.00 1.00 7.50 742.9 1,093.8 1.57 212.51.00 37.31.00 1.00+D+0.750L 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 17.0 ft 1 0.666 0.172 1.15 1.000 1.001.00 1.00 6.77 670.5 1,006.3 1.42 195.51.00 33.71.00 HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.03.01 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M3 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+0.60D 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 17.0 ft 1 0.230 0.059 1.60 1.000 1.001.00 1.00 3.25 321.8 1,400.0 0.68 272.01.00 16.21.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+0.750Lr+0.750L 1 0.4333 8.562 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.766 1.766 Max Upward from Load Combinations 1.766 1.766 Max Upward from Load Cases 1.275 1.275 D Only 1.275 1.275 +D+L 1.700 1.700 +D+Lr 1.505 1.505 +D+0.750Lr+0.750L 1.766 1.766 +D+0.750L 1.594 1.594 +0.60D 0.765 0.765 Lr Only 0.230 0.230 L Only 0.425 0.425 HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.03.01 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M4 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-05 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.2E 2900 2900 2900 750 2200 1118.19 290 2025 45.07 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-05 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.20, Lr = 0.040, L = 0.0850 , Tributary Width = 1.0 ft Point Load : D = 0.750 k @ 4.0 ft Point Load : D = 0.20 k @ 18.0 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.705: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 10.679ft 106.06 psi= = 2,850.80psi 3.5x14.0Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 290.00 psi== Section used for this span 3.5x14.0 Maximum Shear Stress Ratio 0.366 : 1 0.000 ft= = 2,010.95psi Maximum Deflection 0 <360 265 Ratio =0 <180 Max Downward Transient Deflection 0.256 in 1031Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.993 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+0.750Lr+0.750L n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 22.0 ft 1 0.574 0.308 0.90 0.983 1.001.00 1.00 14.02 1,472.0 2,565.7 2.63 261.01.00 80.41.00 1.00+D+L 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.705 0.366 1.00 0.983 1.001.00 1.00 19.16 2,011.0 2,850.8 3.46 290.01.00 106.11.00 1.00+D+Lr 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.484 0.255 1.25 0.983 1.001.00 1.00 16.44 1,725.6 3,563.5 3.02 362.51.00 92.51.00 1.00+D+0.750Lr+0.750L 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.580 0.300 1.25 0.983 1.001.00 1.00 19.69 2,066.5 3,563.5 3.55 362.51.00 108.71.00 1.00+D+0.750L 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.03.01 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M4 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 22.0 ft 1 0.572 0.299 1.15 0.983 1.001.00 1.00 17.88 1,876.2 3,278.4 3.25 333.51.00 99.61.00 1.00+0.60D 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.194 0.104 1.60 0.983 1.001.00 1.00 8.41 883.2 4,561.3 1.58 464.01.00 48.21.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+0.750Lr+0.750L 1 0.9932 10.920 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 3.881 3.531 Max Upward from Load Combinations 3.881 3.531 Max Upward from Load Cases 2.850 2.500 D Only 2.850 2.500 +D+L 3.785 3.435 +D+Lr 3.290 2.940 +D+0.750Lr+0.750L 3.881 3.531 +D+0.750L 3.551 3.201 +0.60D 1.710 1.500 Lr Only 0.440 0.440 L Only 0.935 0.935 HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.03.01 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M5 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-05 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.2E 2,900.0 2,900.0 2,900.0 750.0 2,200.0 1,118.19 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-05 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.110, Lr = 0.040, L = 0.0750 , Tributary Width = 1.0 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.412: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 11.000ft 55.93 psi= = 2,850.80psi 3.5x14.0Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 290.00 psi== Section used for this span 3.5x14.0 Maximum Shear Stress Ratio 0.193 : 1 20.876 ft= = 1,174.72psi Maximum Deflection 0 <360 446 Ratio =0 <180 Max Downward Transient Deflection 0.226 in 1169Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.591 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+0.750Lr+0.750L n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 22.0 ft 1 0.272 0.127 0.90 0.983 1.001.00 1.00 6.66 698.5 2,565.7 1.09 261.01.00 33.31.00 1.00+D+L 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.412 0.193 1.00 0.983 1.001.00 1.00 11.19 1,174.7 2,850.8 1.83 290.01.00 55.91.00 1.00+D+Lr 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.267 0.125 1.25 0.983 1.001.00 1.00 9.08 952.5 3,563.5 1.48 362.51.00 45.31.00 1.00+D+0.750Lr+0.750L 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.350 0.164 1.25 0.983 1.001.00 1.00 11.87 1,246.2 3,563.5 1.94 362.51.00 59.31.00 1.00+D+0.750L 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.322 0.151 1.15 0.983 1.001.00 1.00 10.06 1,055.7 3,278.4 1.64 333.51.00 50.31.00 HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.03.01 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M5 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+0.60D 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.092 0.043 1.60 0.983 1.001.00 1.00 3.99 419.1 4,561.3 0.65 464.01.00 20.01.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+0.750Lr+0.750L 1 0.5909 11.080 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 2.159 2.159 Max Upward from Load Combinations 2.159 2.159 Max Upward from Load Cases 1.210 1.210 D Only 1.210 1.210 +D+L 2.035 2.035 +D+Lr 1.650 1.650 +D+0.750Lr+0.750L 2.159 2.159 +D+0.750L 1.829 1.829 +0.60D 0.726 0.726 Lr Only 0.440 0.440 L Only 0.825 0.825 HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.03.01 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-05 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.2E 2,900.0 2,900.0 2,900.0 750.0 2,200.0 1,118.19 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-05 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.110, Lr = 0.040, L = 0.080 , Tributary Width = 1.0 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.423: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 11.000ft 57.44 psi= = 2,850.80psi 3.5x14.0Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 290.00 psi== Section used for this span 3.5x14.0 Maximum Shear Stress Ratio 0.198 : 1 20.876 ft= = 1,206.47psi Maximum Deflection 0 <360 438 Ratio =0 <180 Max Downward Transient Deflection 0.241 in 1095Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.602 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+0.750Lr+0.750L n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 22.0 ft 1 0.272 0.127 0.90 0.983 1.001.00 1.00 6.66 698.5 2,565.7 1.09 261.01.00 33.31.00 1.00+D+L 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.423 0.198 1.00 0.983 1.001.00 1.00 11.50 1,206.5 2,850.8 1.88 290.01.00 57.41.00 1.00+D+Lr 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.267 0.125 1.25 0.983 1.001.00 1.00 9.08 952.5 3,563.5 1.48 362.51.00 45.31.00 1.00+D+0.750Lr+0.750L 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.356 0.167 1.25 0.983 1.001.00 1.00 12.10 1,270.0 3,563.5 1.98 362.51.00 60.51.00 1.00+D+0.750L 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.329 0.154 1.15 0.983 1.001.00 1.00 10.29 1,079.5 3,278.4 1.68 333.51.00 51.41.00 HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.03.01 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M6 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+0.60D 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.092 0.043 1.60 0.983 1.001.00 1.00 3.99 419.1 4,561.3 0.65 464.01.00 20.01.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+0.750Lr+0.750L 1 0.6022 11.080 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 2.200 2.200 Max Upward from Load Combinations 2.200 2.200 Max Upward from Load Cases 1.210 1.210 D Only 1.210 1.210 +D+L 2.090 2.090 +D+Lr 1.650 1.650 +D+0.750Lr+0.750L 2.200 2.200 +D+0.750L 1.870 1.870 +0.60D 0.726 0.726 Lr Only 0.440 0.440 L Only 0.880 0.880 HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.07.24 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M7 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-05 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist MicroLam LVL 2.0 E 2,600.0 2,600.0 2,510.0 750.0 2,000.0 1,016.54 285.0 1,555.0 42.010 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-05 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0530, Lr = 0.070 , Tributary Width = 1.0 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.441: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 8.500ft 70.94 psi= = 3,278.65psi 1.75x11.25Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 356.25 psi== Section used for this span 1.75x11.25 Maximum Shear Stress Ratio 0.199 : 1 0.000 ft= = 1,444.45psi Maximum Deflection 640 <360 364 Ratio =0 <180 Max Downward Transient Deflection 0.319 in 0 Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.560 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 17.0 ft 1 0.264 0.119 0.90 1.009 1.001.00 1.00 1.91 622.4 2,360.6 0.40 256.51.00 30.61.00 1.00+D+Lr 1.009 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 17.0 ft 1 0.441 0.199 1.25 1.009 1.001.00 1.00 4.44 1,444.4 3,278.7 0.93 356.31.00 70.91.00 1.00+D+0.750Lr 1.009 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 17.0 ft 1 0.378 0.171 1.25 1.009 1.001.00 1.00 3.81 1,238.9 3,278.7 0.80 356.31.00 60.81.00 1.00+0.60D 1.009 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 17.0 ft 1 0.089 0.040 1.60 1.009 1.001.00 1.00 1.15 373.4 4,196.7 0.24 456.01.00 18.31.00 . HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.07.24 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M7 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.5598 8.562 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.046 1.046 Max Upward from Load Combinations 1.046 1.046 Max Upward from Load Cases 0.595 0.595 D Only 0.451 0.451 +D+Lr 1.046 1.046 +D+0.750Lr 0.897 0.897 +0.60D 0.270 0.270 Lr Only 0.595 0.595 HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.07.24 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M8 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : W = 0.0220 , Tributary Width = 1.0 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.285: 1 Load Combination +0.60W Span # where maximum occurs Span # 1 Location of maximum on span 4.000ft 8.55 psi= = 2,152.80psi 2x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +0.60W = = = 288.00 psi== Section used for this span 2x6 Maximum Shear Stress Ratio 0.030 : 1 7.562 ft= = 614.40psi Maximum Deflection 0 <240 194 Ratio =0 <120 Max Downward Transient Deflection 0 in 0 Ratio = <240 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.494 in Ratio = >=120 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v n/a n/a Span: 1 : +0.60W n/a (weak orientation) (weak orientation) .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 0.0 0.00 0.00.0 1.00Length = 8.0 ft 1 0.90 1.300 1.151.00 1.00 1,211.0 0.00 162.01.00 0.01.00 1.00+0.60W 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.285 0.030 1.60 1.300 1.151.00 1.00 0.11 614.4 2,152.8 0.05 288.01.00 8.51.00 1.00+0.450W 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.214 0.022 1.60 1.300 1.151.00 1.00 0.08 460.8 2,152.8 0.04 288.01.00 6.41.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +0.60W 1 0.4944 4.029 0.0000 0.000 . HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.07.24 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M8 Project Title: Engineer: Project ID: Project Descr: Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.088 0.088 Max Upward from Load Combinations 0.053 0.053 Max Upward from Load Cases 0.088 0.088 +0.60W 0.053 0.053 +0.450W 0.040 0.040 W Only 0.088 0.088 HOLD- 420 W 17th St3/7/2025 Steel Beam LIC# : KW-06011706, Build:20.24.07.24 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M9 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per AISC 360-16, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Analysis Method : ksi Bending Axis : Major Axis Bending Completely Unbraced Allowable Strength Design Fy : Steel Yield : 46.0 ksi Beam Bracing : E: Modulus : 29,000.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Beam self weight NOT internally calculated and addedLoad for Span Number 1 Uniform Load : W = 0.360 k/ft, Tributary Width = 1.0 ftLoad for Span Number 2 Uniform Load : W = 0.360 k/ft, Tributary Width = 1.0 ft .Design OKDESIGN SUMMARY Maximum Bending Stress Ratio =0.101 : 1 Load Combination +0.60W Span # where maximum occurs Span # 1 0.7167 k Mn / Omega : Allowable 6.657k-ft Vn/Omega : Allowable HSS3x3x5/16Section used for this span Span # where maximum occurs Location of maximum on span Span # 1 Load Combination +0.60W 20.459 k Section used for this span HSS3x3x5/16 Ma : Applied Maximum Shear Stress Ratio =0.035 : 1 5.500 ft 0.675k-ft Va : Applied 36,061 >=240. 2870 Ratio =60102 >=120. Maximum Deflection Max Downward Transient Deflection 0.038 in 1,721Ratio = >=240. Max Upward Transient Deflection -0.002 in Ratio = Max Downward Total Deflection 0.023 in Ratio = >=120. Max Upward Total Deflection -0.001 in Span: 2 : W Only Span: 2 : W Only Span: 2 : +0.60W Span: 2 : +0.60W .Maximum Forces & Stresses for Load Combinations Span # Summary of Moment ValuesLoad Combination Summary of Shear ValuesMax Stress Ratios M V Mmax -Mmax + Rm VnxMa Max Mnx/Omega Cb Va MaxMnx Vnx/OmegaSegment Length Dsgn. L = 5.50 ft 1 0.000 11.12 6.66 1.00 1.00 -0.00 34.17 20.46 Dsgn. L = 2.50 ft 2 0.000 11.12 6.66 1.00 1.00 -0.00 34.17 20.46 +0.60W Dsgn. L = 5.50 ft 1 0.101 0.035 0.51 -0.68 0.68 11.12 6.66 1.61 1.00 0.72 34.17 20.46 Dsgn. L = 2.50 ft 2 0.101 0.026 -0.68 0.68 11.12 6.66 1.00 1.00 0.54 34.17 20.46 +0.450W Dsgn. L = 5.50 ft 1 0.076 0.026 0.39 -0.51 0.51 11.12 6.66 1.61 1.00 0.54 34.17 20.46 Dsgn. L = 2.50 ft 2 0.076 0.020 -0.51 0.51 11.12 6.66 1.00 1.00 0.41 34.17 20.46 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections W Only 1 0.0383 2.442 0.0000 0.000 W OnlyW Only 2 0.0116 2.500 -0.0017 0.470 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.785 2.095 Max Upward from Load Combinations 0.471 1.257 Max Upward from Load Cases 0.785 2.095 +0.60W 0.471 1.257 HOLD- 420 W 17th St3/7/2025 Steel Beam LIC# : KW-06011706, Build:20.24.07.24 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M9 Project Title: Engineer: Project ID: Project Descr: Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS +0.450W 0.353 0.943 W Only 0.785 2.095 HOLD- 420 W 17th St3/7/2025 Steel Column LIC# : KW-06011706, Build:20.24.07.24 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M10 Project Title: Engineer: Project ID: Project Descr: .Code References Calculations per AISC 360-16, IBC 2021, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Steel Stress Grade Top & Bottom PinnedAnalysis Method : 8.0Overall Column Height Top & Bottom FixityAllowable Strength Fy : Steel Yield ksi29,000.0 ksi Steel Section Name :HSS3x3x5/16 46.0 ft E : Elastic Bending Modulus Unbraced Length for buckling ABOUT X-X Axis = 8 ft, K = 1.0 Unbraced Length for buckling ABOUT Y-Y Axis = 8 ft, K = 1.0 Brace condition : .Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weight included : 84.640 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 8.0 ft, W = 2.10 k .DESIGN SUMMARY PASS Max. Axial+Bending Stress Ratio =0.02825 Location of max.above base 0.0 ft 1.345 k 47.595 k 0.0 k-ft Load Combination +D+0.60W Load Combination 0.0 6.657 k-ft Bending & Shear Check Results PASS Maximum Shear Stress Ratio = 0.0 k 0.0 : 1 Location of max.above base 0.0 ft At maximum location values are . . . : 1 At maximum location values are . . . k 6.657 k-ft 0.0 k-ft Pa : Axial Pn / Omega : Allowable Ma-x : Applied Mn-x / Omega : Allowable Ma-y : Applied Mn-y / Omega : Allowable Va : Applied Vn / Omega : Allowable Maximum Load Reactions . . Top along X-X 0.0 k Bottom along X-X 0.0 k Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Maximum Load Deflections . . . Along Y-Y 0.0 in at 0.0ft above base for load combination : Along X-X 0.0 in at 0.0ft above base for load combination : 0.0 . Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination Stress Ratio Location Stress Ratio Status LocationStatus Load Combination Results Cbx Cby KxLx/Rx KyLy/Ry D Only PASS PASS0.00 0.000 0.00 ftft0.002 1.00 1.00 88.89 88.89 +D+0.60W PASS PASS0.00 0.000 0.00 ftft0.028 1.00 1.00 88.89 88.89 +D+0.450W PASS PASS0.00 0.000 0.00 ftft0.022 1.00 1.00 88.89 88.89 +0.60D+0.60W PASS PASS0.00 0.000 0.00 ftft0.028 1.00 1.00 88.89 88.89 +0.60D PASS PASS0.00 0.000 0.00 ftft0.001 1.00 1.00 88.89 88.89 . k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis ReactionAxial Reaction @ Base @ Top@ Base @ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top Mx - End Moments My - End Moments D Only 0.085 +D+0.60W 1.345 +D+0.450W 1.030 +0.60D+0.60W 1.311 +0.60D 0.051 W Only 2.100 k k-ft Item X-X Axis Reaction Y-Y Axis ReactionAxial Reaction @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx - End Moments My - End Moments MaximumAxial @ Base 2.100 Minimum" 0.051 HOLD- 420 W 17th St3/7/2025 Steel Column LIC# : KW-06011706, Build:20.24.07.24 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M10 Project Title: Engineer: Project ID: Project Descr: k k-ft Item X-X Axis Reaction Y-Y Axis ReactionAxial Reaction @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx - End Moments My - End Moments MaximumReaction, X-X Axis Base 0.085 Minimum" 0.085 MaximumReaction, Y-Y Axis Base 0.085 Minimum" 0.085 MaximumReaction, X-X Axis Top 0.085 Minimum" 0.085 MaximumReaction, Y-Y Axis Top 0.085 Minimum" 0.085 MaximumMoment, X-X Axis Base 0.085 Minimum" 0.085 MaximumMoment, Y-Y Axis Base 0.085 Minimum" 0.085 MaximumMoment, X-X Axis Top 0.085 Minimum" 0.085 MaximumMoment, Y-Y Axis Top 0.085 Minimum" 0.085 .Maximum Deflections for Load Combinations Max. Deflection in X dir Max. Deflection in Y dir DistanceLoad Combination Distance D Only 0.0000 0.000 0.000 ftft inin 0.000 +D+0.60W 0.0000 0.000 0.000 ftft inin 0.000 +D+0.450W 0.0000 0.000 0.000 ftft inin 0.000 +0.60D+0.60W 0.0000 0.000 0.000 ftft inin 0.000 +0.60D 0.0000 0.000 0.000 ftft inin 0.000 W Only 0.0000 0.000 0.000 ftft inin 0.000 .Steel Section Properties :HSS3x3x5/16 R xx = 1.080 in Depth = 3.000 in R yy = 1.080 in J = 5.940 in^4 Width = 3.000 in Wall Thick = 0.313 in Zx = 2.900 in^3 Area = 2.940 in^2 Weight = 10.580 plf I xx = 3.45 in^4 S xx = 2.30 in^3Design Thick = 0.291 in I yy = 3.450 in^4 C = 4.180 in^3 S yy = 2.300 in^3 Ycg = 0.000 in HOLD- 420 W 17th St3/7/2025 Steel Column LIC# : KW-06011706, Build:20.24.07.24 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M10 Project Title: Engineer: Project ID: Project Descr: Sketches HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.07.24 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M11 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900 900 1350 625 1600 580 180 575 31.21 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.030, Lr = 0.040 , Tributary Width = 1.0 ft Point Load : W = 2.10 k @ 8.0 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.616: 1 Load Combination +D+0.60W Span # where maximum occurs Span # 1 Location of maximum on span 8.000ft 34.15 psi= = 1,584.00psi 4x12Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+0.750Lr+0.450W = = = 288.00 psi== Section used for this span 4x12 Maximum Shear Stress Ratio 0.119 : 1 15.066 ft= = 975.24psi Maximum Deflection 409 <360 551 Ratio =0 <180 Max Downward Transient Deflection 0.469 in 0 Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.348 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : W Only n/a Span: 1 : +D+0.60W n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 16.0 ft 1 0.175 0.050 0.90 1.100 1.001.00 1.00 0.96 156.0 891.0 0.21 162.01.00 8.11.00 1.00+D+Lr 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.294 0.084 1.25 1.100 1.001.00 1.00 2.24 364.1 1,237.5 0.49 225.01.00 18.81.00 1.00+D+0.750Lr 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.252 0.072 1.25 1.100 1.001.00 1.00 1.92 312.1 1,237.5 0.42 225.01.00 16.21.00 1.00+D+0.60W 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.616 0.111 1.60 1.100 1.001.00 1.00 6.00 975.2 1,584.0 0.84 288.01.00 32.11.00 1.00+D+0.750Lr+0.450W 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.07.24 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M11 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 16.0 ft 1 0.585 0.119 1.60 1.100 1.001.00 1.00 5.70 926.5 1,584.0 0.90 288.01.00 34.21.00 1.00+D+0.450W 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.486 0.091 1.60 1.100 1.001.00 1.00 4.74 770.4 1,584.0 0.68 288.01.00 26.11.00 1.00+0.60D+0.60W 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.576 0.100 1.60 1.100 1.001.00 1.00 5.62 912.8 1,584.0 0.76 288.01.00 28.81.00 1.00+0.60D 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.059 0.017 1.60 1.100 1.001.00 1.00 0.58 93.6 1,584.0 0.13 288.01.00 4.81.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections W Only 1 0.4686 8.000 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.050 1.050 Max Upward from Load Combinations 0.953 0.953 Max Upward from Load Cases 1.050 1.050 D Only 0.240 0.240 +D+Lr 0.560 0.560 +D+0.750Lr 0.480 0.480 +D+0.60W 0.870 0.870 +D+0.750Lr+0.450W 0.953 0.953 +D+0.450W 0.713 0.713 +0.60D+0.60W 0.774 0.774 +0.60D 0.144 0.144 Lr Only 0.320 0.320 W Only 1.050 1.050 HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.07.24 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M12 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.2E 2900 2900 2900 750 2200 1118.19 290 2025 45.07 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.030, Lr = 0.040 , Tributary Width = 1.0 ft Point Load : W = 2.10 k @ 5.0 ft Point Load : W = 2.10 k @ 10.0 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.185: 1 Load Combination +D+0.60W Span # where maximum occurs Span # 1 Location of maximum on span 9.956ft 39.94 psi= = 4,561.28psi 5.25x14.0Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+0.60W = = = 464.00 psi== Section used for this span 5.25x14.0 Maximum Shear Stress Ratio 0.086 : 1 0.000 ft= = 845.96psi Maximum Deflection 527 <360 733 Ratio =0 <180 Max Downward Transient Deflection 0.500 in 0 Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.360 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : W Only n/a Span: 1 : +D+0.60W n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 22.0 ft 1 0.049 0.023 0.90 0.983 1.001.00 1.00 1.82 127.0 2,565.7 0.30 261.01.00 6.01.00 1.00+D+Lr 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.083 0.039 1.25 0.983 1.001.00 1.00 4.24 296.3 3,563.5 0.69 362.51.00 14.11.00 1.00+D+0.750Lr 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.071 0.033 1.25 0.983 1.001.00 1.00 3.63 254.0 3,563.5 0.59 362.51.00 12.11.00 1.00+D+0.60W 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.185 0.086 1.60 0.983 1.001.00 1.00 12.09 846.0 4,561.3 1.96 464.01.00 39.91.00 HOLD- 420 W 17th St3/7/2025 Wood Beam LIC# : KW-06011706, Build:20.24.07.24 George Kiledjian (c) ENERCALC INC 1983-2023 DESCRIPTION:M12 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+D+0.750Lr+0.450W 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.174 0.081 1.60 0.983 1.001.00 1.00 11.32 791.8 4,561.3 1.84 464.01.00 37.51.00 1.00+D+0.450W 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.146 0.068 1.60 0.983 1.001.00 1.00 9.52 665.9 4,561.3 1.54 464.01.00 31.51.00 1.00+0.60D+0.60W 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.174 0.081 1.60 0.983 1.001.00 1.00 11.37 795.6 4,561.3 1.84 464.01.00 37.51.00 1.00+0.60D 0.983 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.017 0.008 1.60 0.983 1.001.00 1.00 1.09 76.2 4,561.3 0.18 464.01.00 3.61.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections W Only 1 0.5002 10.358 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 2.768 1.432 Max Upward from Load Combinations 1.991 1.304 Max Upward from Load Cases 2.768 1.432 D Only 0.330 0.330 +D+Lr 0.770 0.770 +D+0.750Lr 0.660 0.660 +D+0.60W 1.991 1.189 +D+0.750Lr+0.450W 1.906 1.304 +D+0.450W 1.576 0.974 +0.60D+0.60W 1.859 1.057 +0.60D 0.198 0.198 Lr Only 0.440 0.440 W Only 2.768 1.432 HOLD- 420 W 17th St3/7/2025 BIG SAVER FOODS, INC. 4260 Charter St, Vernon, CA 90058 December 21, 2023 CITY OF SANTA ANA PLANNING DEPARTMENT 20 Civic Center Plaza Santa Ana, CA 92701 Subject: Pledge to Address Fire Suppression System and OCFA Block for Tenant Improvement Project Dear Planning Department Official David Chavez, I am writing on behalf of BIG SAVER FOODS, INC. to express our commitment to ensuring compliance with all fire safety regulations as part of our upcoming tenant improvement project at 420 W 17Th Street Santa Ana CA, 92706. As we move forward with the construction, we understand the critical importance of addressing the fire suppression system and the OCFA block requirements, to ensure the safety and well-being of our occupants. We recognize the importance of these components in meeting the necessary safety standards set forth by the City of Santa Ana and the Orange County Fire Authority (OCFA). Our commitment includes: 1. Engage certified professionals to conduct a comprehensive assessment of the existing fire suppression system and OCFA block. 2. Implement all necessary modifications and upgrades as recommended promptly. 3. Collaborating with authorities for necessary permits and inspections. 4. Ensure the process is completed prior to final inspection. As we progress with the construction, we will keep the Planning and Building Departments informed of our progress and provide any required documentation promptly. We appreciate the support and guidance and look forward to contributing to the safety and prosperity of the Santa Ana community. Thank you for your attention to this matter. Should you require any additional information or clarification, please do not hesitate to contact me at 323-582-7222 ext. 242 or via email jhuerta@bigsaverfoods.com. Sincerely, Jose Huerta Chief Executive Officer 323-582-7222 ext. 242 jhuerta@bigsaverfoods.com HOLD- 420 W 17th St3/7/2025 GREASE INTERCEPTOR MEMORANDUM To: Uka Solanki – Applicant Date: April 25, 2024 From: Hector Medina – Assistant Engineer, PWA Water Resources Division Location: 420 W. 17TH ST. – BIG SAVER FOODS The above referenced food service establishment (FSE) must comply with the Fats, Oils, and Grease (FOG) Control Program Rules and Regulations as identified in Ordinance NS-2921 and as follows: A Gravity Grease Interceptor (GGI) is required at this FSE ☒ This FSE shall install a Gravity Grease Interceptor (GGI). ☐ This FSE shall maintain the existing Gravity Grease Interceptor (GGI). This FSE qualifies for at least one of the following condition(s): This is a new FSE, or; This is an existing FSE undergoing remodeling, or; This is an existing FSE involving a change (of operation, ownership, and/or name) that is likely to continue discharging a high level of FOG or has the potential to increase the amount of FOG discharged to the sewer system. C/c: Water Resources Division Planning & Building Agency OC Health Care Agency Public Works Agency (Development) EEC Environmental Applicant HOLD- 420 W 17th St3/7/2025 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM HOLD- 420 W 17th St3/7/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs HOLD- 420 W 17th St3/7/2025