Loading...
HomeMy WebLinkAboutHOLD - 2037 S Garnsey St & #2 - PlanBldg #'s 102119036-37 APPROVALS: PLNG - F. Arias BLDG - T. Le POLICE - B. Martin PUBLIC WORKS - B. Sarlak HOLD - 2037 S Garnsey St & #24/10/2025 HOLD - 2037 S Garnsey St & #24/10/2025 HOLD - 2037 S Garnsey St & #24/10/2025 HOLD - 2037 S Garnsey St & #24/10/2025 HOLD - 2037 S Garnsey St & #24/10/2025 HOLD - 2037 S Garnsey St & #24/10/2025 HOLD - 2037 S Garnsey St & #24/10/2025 HOLD - 2037 S Garnsey St & #24/10/2025 T-24-1T-24-1 2037 S Garnsey St Addition Santa Ana, Ca 92707 HOLD - 2037 S Garnsey St & #24/10/2025 T-24-1T-24-1 2037 S Garnsey St Unit #2 ADU Conversion Santa Ana, Ca 92707 HOLD - 2037 S Garnsey St & #24/10/2025 T-24-2 2037 S Garnsey St Addition Santa Ana, Ca 92707 HOLD - 2037 S Garnsey St & #24/10/2025 T-24-2 Pages from 17-001-1-1.jpg Pages from 17-001-1-1.jpg 2037 S Garnsey St Unit #2 ADU Conversion Santa Ana, Ca 92707 2022 Single-Family Residential Mandatory Requirements Summary NOTE: Single-family residential buildings subject to the Energy Codes must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. (04/2022) Building Envelope: § 110.6(a)1: § 110.6(a)5: § 110.6(b): § 110.7: § 110.8(a): § 110.8(g): § 110.8(i): § 110.8(j): § 150.0(a): § 150.0(b): § 150.0(c): § 150.0(d): § 150.0(f): § 150.0(g)1: § 150.0(g)2: § 150.0(q): Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less when tested per NFRC-400, ASTM E283, or AAMA/WDMA/CSA 101/I.S.2/A440-2011. * Labeling. Fenestration products and exterior doors must have a label meeting the requirements of § 10-111(a). Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables 110.6-A, 110.6-B, or JA4.5 for exterior doors. They must be caulked and/or weather-stripped. * Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, gasketed, or weather stripped. Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods and Services (BHGS). Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8(i) and be labeled per §10-113 when the installation of a cool roof is specified on the CF1R. Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Roof Deck, Ceiling and Rafter Roof Insulation. Roof decks in newly constructed attics in climate zones 4 and 8-16 area-weighted average U-factor not exceeding U-0.184. Ceiling and rafter roofs minimum R-22 insulation in wood-frame ceiling; or area-weighted average U-factor must not exceed 0.043. Rafter roof alterations minimum R-19 or area-weighted average U-factor of 0.054 or less. Attic access doors must have permanently attached insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling. * Loose-fill Insulation. Loose fill insulation must meet the manufacturer’s required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or have a U-factor of 0.071 or less. Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls must meet Tables 150.1-A or B. * Raised-floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor. * Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawl space for buildings complying with the exception to §150.0(d). Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air-permeable insulation. Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.45; or area-weighted average U-factor of all fenestration must not exceed 0.45. * Fireplaces, Decorative Gas Appliances, and Gas Log: § 110.5(e) § 150.0(e)1: § 150.0(e)2: § 150.0(e)3: Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces. Closable Doors. Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. Combustion Intake. Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight-fitting damper or combustion-air control device. * Flue Damper. Masonry or factory-built fireplaces must have a flue damper with a readily accessible control. * Space Conditioning, Water Heating, and Plumbing System: § 110.0-§ 110.3: § 110.2(a): § 110.2(b): § 110.2(c): § 110.3(c)3: § 110.3(c)6: 5/6/22 Certification. Heating, ventilation, and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the California Energy Commission. * HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-N. * Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating. * Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat. * Insulation. Unfired service water heater storage tanks and solar water-heating backup tanks must have adequate insulation, or tank surface heat loss rating. Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed. 2022 Single-Family Residential Mandatory Requirements Summary § 110.5: § 150.0(h)1: § 150.0(h)3A: § 150.0(h)3B: § 150.0(j)1: § 150.0(j)2: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces; household cooking appliances (except appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour ); and pool and spa heaters. * Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook, Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2. Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer. Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the manufacturer’s instructions. Water Piping, Solar Water-heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must be insulated as specified in § 609.11 of the California Plumbing Code. * Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment` maintenance, and wind as required by §120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes). Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve. § 150.0(n)1: § 150.0(n)3: Ducts and Fans: § 110.8(d)3: Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must designate a space at least 2.5’ x 2.5’ x 7’ suitable for the future installation of a heat pump water heater, and meet electrical and plumbing requirements, based on the distance between this designated space and the water heater location; and a condensate drain no more than 2” higher than the base of the water heater Solar Water-heating Systems. Solar water-heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing agency that is approved by the executive director. Ducts. Insulation installed on an existing space-conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. § 150.0(m)1: CMC Compliance. All air-distribution system ducts and plenums must meet CMC §§ 601.0-605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply-air and return-air ducts and plenums must be insulated to R-6.0 or higher; ducts located entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8) do not require insulation. Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct-closure system that meets the applicable UL requirements, or aerosol sealant that meets UL 723. The combination of mastic and either mesh or tape must be used to seal openings greater than ¼”, If mastic or tape is used. Building cavities, air handler support platforms, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air. Building cavities and support platforms may contain ducts; ducts installed in these spaces must not be compressed. * § 150.0(m)2: § 150.0(m)3: § 150.0(m)7: § 150.0(m)8: § 150.0(m)9: § 150.0(m)10: § 150.0(m)11: § 150.0(m)12: Factory-Fabricated Duct Systems. Factory-fabricated duct systems must comply with applicable requirements for duct construction, connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. Field-Fabricated Duct Systems. Field-fabricated duct systems must comply with applicable requirements for: pressure-sensitive tapes, mastics, sealants, and other requirements specified for duct construction. Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers. Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage due tosunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather must be suitable for outdoor service (e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover). Cellular foam insulation must be protected as above or painted with a water retardant and solar radiation-resistant coating. Porous Inner Core Flex Duct. Porous inner cores of flex ducts must have a non-porous layer or air barrier between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.1. Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Clean-filter pressure drop and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service. Filter racks or grilles must use gaskets, sealing, or other means to close gaps around the inserted filters to and prevents air from bypassing the filter. * 5/6/22 2022 Single-Family Residential Mandatory Requirements Summary § 150.0(m)13: Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be ≥ 350 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy ≤ 0.45 watts per CFM for gas furnace air handlers and ≤ 0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow ≥ 250 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy ≤ 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3. * Ventilation and Indoor Air Quality: § 150.0(o)1: § 150.0(o)1B: Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1. * Central Fan Integrated (CFI) Ventilation Systems. Continuous operation of CFI air handlers is not allowed to provide the whole- dwelling unit ventilation airflow required per §150.0(o)1C. A motorized damper(s) must be installed on the ventilation duct(s) that prevents all airflow through the space conditioning duct system when the damper(s) is closed andcontrolled per §150.0(o)1Biii&iv. CFI ventilation systems must have controls that track outdoor air ventilation run time, and either open or close the motorized damper(s) for compliance with §150.0(o)1C. § 150.0(o)1C: § 150.0(o)1G: Whole-Dwelling Unit Mechanical Ventilation for Single-Family Detached and townhouses . Single-family detached dwelling units, and attached dwelling units not sharing ceilings or floors with other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow specified in § 150.0(o)1Ci-iii. Local Mechanical Exhaust. Kitchens and bathrooms must have local mechanical exhaust; nonenclosed kitchens must have demand- controlled exhaust system meeting requirements of §150.0(o)1Giii,enclosed kitchens and bathrooms can use demand-controlled or continuous exhaust meeting §150.0(o)1Giii-iv. Airflow must be measured by the installer per §150.0(o)1Gv, and rated for sound per §150.0(o)1Gvi. * § 150.0(o)1H&I: Airflow Measurement and Sound Ratings of Whole-Dwelling Unit Ventilation Systems. The airflow required per § 150.0(o)1C must be measured by using a flow hood, flow grid, or other airflow measuring device at the fan’s inlet or outlet terminals/grilles per Reference Residential Appendix RA3.7. Whole-Dwelling unit ventilation systems must be rated for sound per ASHRAE 62.2 §7.2 at no less than the minimum airflow rate required by §150.0(o)1C. § 150.0(o)2: Field Verification and Diagnostic Testing. Whole-Dwelling Unit ventilation airflow, vented range hood airflow and sound rating, and HRV and ERV fan efficacy must be verified in accordance with Reference Residential Appendix RA3.7. Vented range hoods must be verified per Reference Residential Appendix RA3.7.4.3 to confirm if it is rated by HVI or AHAM to comply with the airflow rates and sound requirements per §150.0(o)1G Pool and Spa Systems and Equipment: § 110.4(a): § 110.4(b)1: § 110.4(b)2: § 110.4(b)3: § 110.5: § 150.0(p): Lighting: § 110.9: § 150.0(k)1A: § 150.0(k)1B: § 150.0(k)1C: § 150.0(k)1D: § 150.0(k)1E: § 150.0(k)1F: 5/6/22 Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: compliance with the Appliance Efficiency Regulations and listing in MAEDbS; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating. * Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves. * Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9. * Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A, except lighting integral to exhaust fans, kitchen range hoods, bath vanity mirrors, and garage door openers; navigation lighting less than 5 watts; and lighting internal to drawers, cabinets, and linen closets with an efficacy of at least 45 lumens per watt. Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. * Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must not contain screw based sockets, must be airtight, and must be sealed with a gasket or caulk. California Electrical Code § 410.116 must also be met. Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or other device shall be no more than the number of bedrooms. These boxes must be served by a dimmer, vacancy sensor control, low voltage wiring, or fan speed control. Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k). * HOLD - 2037 S Garnsey St & #24/10/2025 T-24-3 2037 S Garnsey St Addition Santa Ana, Ca 92707 2022 Single-Family Residential Mandatory Requirements Summary NOTE: Single-family residential buildings subject to the Energy Codes must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. (04/2022) Building Envelope: § 110.6(a)1: § 110.6(a)5: § 110.6(b): § 110.7: § 110.8(a): § 110.8(g): § 110.8(i): § 110.8(j): § 150.0(a): § 150.0(b): § 150.0(c): § 150.0(d): § 150.0(f): § 150.0(g)1: § 150.0(g)2: § 150.0(q): Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less when tested per NFRC-400, ASTM E283, or AAMA/WDMA/CSA 101/I.S.2/A440-2011. * Labeling. Fenestration products and exterior doors must have a label meeting the requirements of § 10-111(a). Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables 110.6-A, 110.6-B, or JA4.5 for exterior doors. They must be caulked and/or weather-stripped. * Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, gasketed, or weather stripped. Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods and Services (BHGS). Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8(i) and be labeled per §10-113 when the installation of a cool roof is specified on the CF1R. Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Roof Deck, Ceiling and Rafter Roof Insulation. Roof decks in newly constructed attics in climate zones 4 and 8-16 area-weighted average U-factor not exceeding U-0.184. Ceiling and rafter roofs minimum R-22 insulation in wood-frame ceiling; or area-weighted average U-factor must not exceed 0.043. Rafter roof alterations minimum R-19 or area-weighted average U-factor of 0.054 or less. Attic access doors must have permanently attached insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling. * Loose-fill Insulation. Loose fill insulation must meet the manufacturer’s required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or have a U-factor of 0.071 or less. Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls must meet Tables 150.1-A or B. * Raised-floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor. * Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawl space for buildings complying with the exception to §150.0(d). Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air-permeable insulation. Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.45; or area-weighted average U-factor of all fenestration must not exceed 0.45. * Fireplaces, Decorative Gas Appliances, and Gas Log: § 110.5(e) § 150.0(e)1: § 150.0(e)2: § 150.0(e)3: Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces. Closable Doors. Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. Combustion Intake. Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight-fitting damper or combustion-air control device. * Flue Damper. Masonry or factory-built fireplaces must have a flue damper with a readily accessible control. * Space Conditioning, Water Heating, and Plumbing System: § 110.0-§ 110.3: § 110.2(a): § 110.2(b): § 110.2(c): § 110.3(c)3: § 110.3(c)6: 5/6/22 Certification. Heating, ventilation, and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the California Energy Commission. * HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-N. * Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating. * Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat. * Insulation. Unfired service water heater storage tanks and solar water-heating backup tanks must have adequate insulation, or tank surface heat loss rating. Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed. 2022 Single-Family Residential Mandatory Requirements Summary § 110.5: § 150.0(h)1: § 150.0(h)3A: § 150.0(h)3B: § 150.0(j)1: § 150.0(j)2: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces; household cooking appliances (except appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour ); and pool and spa heaters. * Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook, Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2. Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer. Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the manufacturer’s instructions. Water Piping, Solar Water-heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must be insulated as specified in § 609.11 of the California Plumbing Code. * Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment` maintenance, and wind as required by §120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes). Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve. § 150.0(n)1: § 150.0(n)3: Ducts and Fans: § 110.8(d)3: Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must designate a space at least 2.5’ x 2.5’ x 7’ suitable for the future installation of a heat pump water heater, and meet electrical and plumbing requirements, based on the distance between this designated space and the water heater location; and a condensate drain no more than 2” higher than the base of the water heater Solar Water-heating Systems. Solar water-heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing agency that is approved by the executive director. Ducts. Insulation installed on an existing space-conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. § 150.0(m)1: CMC Compliance. All air-distribution system ducts and plenums must meet CMC §§ 601.0-605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply-air and return-air ducts and plenums must be insulated to R-6.0 or higher; ducts located entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8) do not require insulation. Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct-closure system that meets the applicable UL requirements, or aerosol sealant that meets UL 723. The combination of mastic and either mesh or tape must be used to seal openings greater than ¼”, If mastic or tape is used. Building cavities, air handler support platforms, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air. Building cavities and support platforms may contain ducts; ducts installed in these spaces must not be compressed. * § 150.0(m)2: § 150.0(m)3: § 150.0(m)7: § 150.0(m)8: § 150.0(m)9: § 150.0(m)10: § 150.0(m)11: § 150.0(m)12: Factory-Fabricated Duct Systems. Factory-fabricated duct systems must comply with applicable requirements for duct construction, connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. Field-Fabricated Duct Systems. Field-fabricated duct systems must comply with applicable requirements for: pressure-sensitive tapes, mastics, sealants, and other requirements specified for duct construction. Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers. Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage due tosunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather must be suitable for outdoor service (e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover). Cellular foam insulation must be protected as above or painted with a water retardant and solar radiation-resistant coating. Porous Inner Core Flex Duct. Porous inner cores of flex ducts must have a non-porous layer or air barrier between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.1. Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Clean-filter pressure drop and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service. Filter racks or grilles must use gaskets, sealing, or other means to close gaps around the inserted filters to and prevents air from bypassing the filter. * 5/6/22 2022 Single-Family Residential Mandatory Requirements Summary § 150.0(m)13: Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be ≥ 350 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy ≤ 0.45 watts per CFM for gas furnace air handlers and ≤ 0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow ≥ 250 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy ≤ 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3. * Ventilation and Indoor Air Quality: § 150.0(o)1: § 150.0(o)1B: Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1. * Central Fan Integrated (CFI) Ventilation Systems. Continuous operation of CFI air handlers is not allowed to provide the whole- dwelling unit ventilation airflow required per §150.0(o)1C. A motorized damper(s) must be installed on the ventilation duct(s) that prevents all airflow through the space conditioning duct system when the damper(s) is closed andcontrolled per §150.0(o)1Biii&iv. CFI ventilation systems must have controls that track outdoor air ventilation run time, and either open or close the motorized damper(s) for compliance with §150.0(o)1C. § 150.0(o)1C: § 150.0(o)1G: Whole-Dwelling Unit Mechanical Ventilation for Single-Family Detached and townhouses . Single-family detached dwelling units, and attached dwelling units not sharing ceilings or floors with other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow specified in § 150.0(o)1Ci-iii. Local Mechanical Exhaust. Kitchens and bathrooms must have local mechanical exhaust; nonenclosed kitchens must have demand- controlled exhaust system meeting requirements of §150.0(o)1Giii,enclosed kitchens and bathrooms can use demand-controlled or continuous exhaust meeting §150.0(o)1Giii-iv. Airflow must be measured by the installer per §150.0(o)1Gv, and rated for sound per §150.0(o)1Gvi. * § 150.0(o)1H&I: Airflow Measurement and Sound Ratings of Whole-Dwelling Unit Ventilation Systems. The airflow required per § 150.0(o)1C must be measured by using a flow hood, flow grid, or other airflow measuring device at the fan’s inlet or outlet terminals/grilles per Reference Residential Appendix RA3.7. Whole-Dwelling unit ventilation systems must be rated for sound per ASHRAE 62.2 §7.2 at no less than the minimum airflow rate required by §150.0(o)1C. § 150.0(o)2: Field Verification and Diagnostic Testing. Whole-Dwelling Unit ventilation airflow, vented range hood airflow and sound rating, and HRV and ERV fan efficacy must be verified in accordance with Reference Residential Appendix RA3.7. Vented range hoods must be verified per Reference Residential Appendix RA3.7.4.3 to confirm if it is rated by HVI or AHAM to comply with the airflow rates and sound requirements per §150.0(o)1G Pool and Spa Systems and Equipment: § 110.4(a): § 110.4(b)1: § 110.4(b)2: § 110.4(b)3: § 110.5: § 150.0(p): Lighting: § 110.9: § 150.0(k)1A: § 150.0(k)1B: § 150.0(k)1C: § 150.0(k)1D: § 150.0(k)1E: § 150.0(k)1F: 5/6/22 Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: compliance with the Appliance Efficiency Regulations and listing in MAEDbS; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating. * Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves. * Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9. * Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A, except lighting integral to exhaust fans, kitchen range hoods, bath vanity mirrors, and garage door openers; navigation lighting less than 5 watts; and lighting internal to drawers, cabinets, and linen closets with an efficacy of at least 45 lumens per watt. Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. * Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must not contain screw based sockets, must be airtight, and must be sealed with a gasket or caulk. California Electrical Code § 410.116 must also be met. Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or other device shall be no more than the number of bedrooms. These boxes must be served by a dimmer, vacancy sensor control, low voltage wiring, or fan speed control. Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k). * § 150.0(k)1G: § 150.0(k)1H: § 150.0(k)1I: § 150.0(k)2A: § 150.0(k)2B: § 150.0(k)2A: § 150.0(k)2B: § 150.0(k)2C: § 150.0(k)2D: § 150.0(k)2E: § 150.0(k)2F: § 150.0(k)2K: § 150.0(k)3A: § 150.0(k)4: § 150.0(k)5: Solar Readiness: § 110.10(a)1: 2022 Single-Family Residential Mandatory Requirements Summary Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. * Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed. Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems. * Accessible Controls. Lighting must have readily accessible wall-mounted controls that allow the lighting to be manually turned on and off. * Multiple Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the dimmer or sensor is installed to comply with § 150.0(k). Mandatory Requirements. Lighting controls must comply with the applicable requirements of § 110.9. Energy Management Control Systems. An energy management control system (EMCS) may be used to comply with dimming, occupancy, and control requirements if it provides the functionality of the specified control per § 110.9 and the physical controls specified in § 150.0(k)2A. Automatic Shutoff Controls. In bathrooms, garages, laundry rooms, utility rooms and walk-in closets, at least one installed luminaire must be controlled by an occupancy or vacancy sensor providing automatic-off functionality. Lighting inside drawers and cabinets with opaque fronts or doors must have controls that turn the light off when the drawer or door is closed. Dimmers. Lighting in habitable spaces (e.g., living rooms, dining rooms, kitchens, and bedrooms) must have readily accessible wall- mounted dimming controls that allow the lighting to be manually adjusted up and down. Forward phase cut dimmers controlling LED light sources in these spaces must comply with NEMA SSL 7A. Independent controls. Integrated lighting of exhaust fans shall be controlled independently from the fans. Lighting under cabinets or shelves, lighting in display cabinets, and switched outlets must be controlled separately from ceiling-installed lighting. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other buildings on the same lot, must have a manual on/off switch and either a photocell and motion sensor or automatic time switch control) or an astronomical time clock. An energy management control system that provides the specified control functionality and meets all applicable requirements may be used to meet these requirements. Internally illuminated address signs. Internally illuminated address signs must either comply with § 140.8 or consume no more than 5 watts of power. Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Single-family Residences. Single-family residences located in subdivisions with 10 or more single-family residences and where the application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which do not have a photovoltaic system installed, must comply with the requirements of § 110.10(b)-(e). §110.10(b)1A: § 110.10(b)2: § 110.10(b)3A: § 110.10(b)3B: § 110.10(b)4: § 110.10(c): § 110.10(d): § 110.10(e)1: § 110.10(e)2: Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas greater than 10,000 square feet. For single-family residences, the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. * Azimuth. All sections of the solar zone located on steep-sloped roofs must have an azimuth between 90-300° of true north. Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment. * Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the horizontal distance of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. * Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single-family residences and central water-heating systems, a pathway reserved for routing plumbing from the solar zone to the water-heating system. Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b)-(c) must be provided to the occupant. Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit breaker for a future solar electric installation. The reserved space must be permanently marked as “For Future Solar Electric.” Electric and Energy Storage Ready: 5/6/22 2022 Single-Family Residential Mandatory Requirements Summary Energy Storage System (ESS) Ready. All single-family residences must meet all of the following: Either ESS-ready interconnection equipment with backed up capacity of 60 amps or more and four or more ESS supplied branch circuits, or a dedicated raceway from the main service to a subpanel that supplies the branch circuits in § 150.0(s); at least four branch circuits must be identified and have their source collocated at a single panelboard suitable to be supplied by the ESS, with one circuit supplying the refrigerator, one lighting circuit near the primary exit, and one circuit supplying a sleeping room receptacle outlet; main panelboard must have a minimum busbar rating of 225 amps; sufficient space must be reserved to allow future installation of a system isolation equipment/transfer switch within 3’ of the main panelboard, with raceways installed between the panelboard and the switch location to allow the connection of backup power source. Heat Pump Space Heater Ready. Systems using gas or propane furnaces to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the furnace with circuit conductors rated at least 30 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” Electric Cooktop Ready. Systems using gas or propane cooktop to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the cooktop with circuit conductors rated at least 50 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” Electric Clothes Dryer Ready. Clothes dryer locations with gas or propane plumbing to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the dryer location with circuit conductors rated at least 30 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” *Exceptions may apply. HOLD - 2037 S Garnsey St & #24/10/2025 HOLD - 2037 S Garnsey St & #24/10/2025 HOLD - 2037 S Garnsey St & #24/10/2025 SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa-ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Thai Viet Phan COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org INTERIM CITY MANAGER Tom Hatch CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall January 17, 2024 Also sent via email to: elvia714@gmail.com Elvia Lopez 2037 South Garnsey Street Santa Ana, CA 92707 Subject: Address Assignment for a Garage Conversion Accessory Dwelling Unit located at 2037 South Garnsey Street (APN: 015-123-04) in Santa Ana, CA Dear Mr. and Ms. Lopez, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a 372-square-foot garage-conversion ADU located at 2037 South Garnsey Street (APN: 015- 123-04). Notice is hereby given that the following assigned address shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address to be Activated/Posted 2037 South Garnsey Street, To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 667-2753 or by email at PRaj@santa-ana.org. Sincerely, Punkaj Raj, AICP Candidate Planning Technician Exhibit A – Address Plan HOLD - 2037 S Garnsey St & #24/10/2025 Address Letter for 2037 South Garnsey Street Page 2 of 2 c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Mishele Richards, Orange County Fire Authority, GEO Files Coordinator Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Alvaro Nunez, PBA Assistant Director and Code Enforcement Manager HOLD - 2037 S Garnsey St & #24/10/2025 2037 S GARNSEY STREET(E) PRIMARY DWELLING 2037 S GARNSEYSTREET, UNIT 2(N) ADU EXHIBIT A: ADDRESS PLAN HOLD - 2037 S Garnsey St & #24/10/2025 BUILDING ENERGY ANALYSIS REPORT PROJECT: Project Designer: Report Prepared by: Job Number: Date: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2022 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC – www.energysoft.com. Addition 7755 Center Ave 12936 Sandy LN. Downey, Ca 90242 Zevallos Design Design 4 Building Robert Gonzales 563-659-2066 Santa Ana, Ca 92707 10/11/2024 24-964 Huntington Beach , Ca 92648 562-981-4890 2037 S Garnsey St HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:2037 S Garnsey St Calculation Date/Time:2024-10-11T09:56:27-07:00 (Page 1 of 10) Calculation Description:Title 24 Analysis Input File Name:24-964.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-11   09:57:06 GENERAL INFORMATION 01 Project Name 2037 S Garnsey St 02 Run Title Title 24 Analysis 03 Project Location 2037 S Garnsey St 04 City Santa Ana 05 Standards Version 2022 06 Zip code 92707 07 Software Version EnergyPro 9.3 08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)270 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Addition and/or Alteration 13 Number of Bedrooms 3 14 Addition Cond. Floor Area (ft2)159 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2)1315 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)1474 19 Glazing Percentage (%)13.16% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type Natural gas 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 Building does not require field testing or HERS verification 03 This building incorporates one or more Special Features shown below HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:2037 S Garnsey St Calculation Date/Time:2024-10-11T09:56:27-07:00 (Page 2 of 10) Calculation Description:Title 24 Analysis Input File Name:24-964.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-11   09:57:06 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0 23.36 0 24.19 0 -0.83 Space Cooling 0 74.91 0 73.15 0 1.76 IAQ Ventilation 0 0 0 0 0 0 Water Heating 0 44.45 0 31.74 0 12.71 Self Utilization/Flexibility Credit 0 0 Efficiency Compliance Total 0 142.72 0 129.08 0 13.64 Photovoltaics 0 0 Battery 0 Flexibility Indoor Lighting 0 7.12 0 7.12 Appl. & Cooking 0 24.6 0 24.58 Plug Loads 0 37.82 0 37.82 Outdoor Lighting 0 1.67 0 1.67 TOTAL COMPLIANCE 0 213.93 0 200.27 HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:2037 S Garnsey St Calculation Date/Time:2024-10-11T09:56:27-07:00 (Page 3 of 10) Calculation Description:Title 24 Analysis Input File Name:24-964.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-11   09:57:06 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 34.03 30.48 3.55 10.43 Net EUI2 34.03 30.48 3.55 10.43 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Insulation below roof deck HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 2037 S Garnsey St 1474 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Zone 1 Conditioned HVAC System1 1315 8 DHW Sys 1 Existing Unchanged Addition Conditioned HVAC System1 159 8 DHW Sys 1 New HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:2037 S Garnsey St Calculation Date/Time:2024-10-11T09:56:27-07:00 (Page 4 of 10) Calculation Description:Title 24 Analysis Input File Name:24-964.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-11   09:57:06 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg)Wall Exceptions Status Verified Existing Condition Front Wall Zone 1 Default Wall Prior-1978 270 Front 280 65 90 none Existing No Left Wall Zone 1 Default Wall Prior-1978 0 Left 336 52 90 none Existing No Rear Wall Zone 1 Default Wall Prior-1978 90 Back 280 16 90 none Existing No Right Wall Zone 1 Default Wall Prior-1978 180 Right 336 33 90 none Existing No (N) Rear Wall Addition (N) R-15 Wall 0 Left 100 40 90 Extension New n/a (N) Right Wall Addition (N) R-15 Wall 0 Left 80 9 90 Extension New n/a Interior Surface Addition>>Zone 1 Default Wall Prior-19781 n/a n/a 100 0 n/a New No Interior Surface 2 Addition>>Zone 1 Default Wall Prior-19781 n/a n/a 80 0 n/a New No Roof Zone 1 Default Roof Prior-1978 n/a n/a 1315 n/a n/a Existing No (N) Roof Addition (N) R-30 Roof Attic n/a n/a 159 n/a n/a New n/a Raised Floor Zone 1 Default Floor Crawlspace n/a n/a 1315 n/a n/a Existing No (N) Raised Floor Addition (N) R-19 Floor Crawlspace n/a n/a 159 n/a n/a New n/a ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Zone 1 Attic RoofZone 1 Ventilated 4 0.1 0.85 No No Existing No Attic Addition Attic RoofAddition Ventilated 4 0.1 0.85 No No New n/a HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:2037 S Garnsey St Calculation Date/Time:2024-10-11T09:56:27-07:00 (Page 5 of 10) Calculation Description:Title 24 Analysis Input File Name:24-964.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-11   09:57:06 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Name Type Surface Orientatio n Azimuth Width (ft) Heigh t (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Status Verified Existing Condition Windows Window Front Wall Front 270 1 44 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No Windows 2 Window Left Wall Left 0 1 52 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No Windows 3 Window Rear Wall Back 90 1 16 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No Windows 4 Window Right Wall Right 180 1 33 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No Glass Doors Window (N) Rear Wall Left 0 1 40 0.3 NFRC 0.23 NFRC Bug Screen New NA (N) Window Window (N) Right Wall Left 0 1 9 0.3 NFRC 0.23 NFRC Bug Screen New NA OPAQUE DOORS 01 02 03 04 05 06 Name Side of Building Area (ft2)U-factor Status Verified Existing Condition Door Front Wall 21 0.5 Existing No HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:2037 S Garnsey St Calculation Date/Time:2024-10-11T09:56:27-07:00 (Page 6 of 10) Calculation Description:Title 24 Analysis Input File Name:24-964.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-11   09:57:06 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Default Wall Prior-1978 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco (N) R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco Default Wall Prior-19781 Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.277 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Other Side Finish: Gypsum Board Attic RoofZone 1 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Attic RoofAddition Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / 0 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Default Floor Crawlspace Floors Over Crawlspace Wood Framed Floor 2x6 @ 16 in. O. C.R-0 None / None 0.22 Floor Surface: Carpeted Floor Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x6 (N) R-19 Floor Crawlspace Floors Over Crawlspace Wood Framed Floor 2x6 @ 16 in. O. C.R-19 None / None 0.049 Floor Surface: Carpeted Floor Deck: Wood Siding/sheathing/decking Cavity / Frame: R-19 / 2x6 HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:2037 S Garnsey St Calculation Date/Time:2024-10-11T09:56:27-07:00 (Page 7 of 10) Calculation Description:Title 24 Analysis Input File Name:24-964.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-11   09:57:06 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Default Roof Prior-1978 Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O. C.R-11 None / None 0.083 Over Ceiling Joists: R-1.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board (N) R-30 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x6 @ 16 in. O. C.R-30 None / None 0.032 Over Ceiling Joists: R-15.7 insul. Cavity / Frame: R-14.3 / 2x6 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Not Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#)Status Verified Existing Condition Existing Water Heating System DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1)Altered No HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:2037 S Garnsey St Calculation Date/Time:2024-10-11T09:56:27-07:00 (Page 8 of 10) Calculation Description:Title 24 Analysis Input File Name:24-964.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-11   09:57:06 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Name Heating Element Type Tank Type # of Units Tank Vol. (gal) Heating Efficiency Type Efficiency Rated Input Type Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff 1st Hr. Rating or Flow Rate Tank Location Status Verified Existing Condition DHW Heater 1 Gas Consumer Storage 1 50 UEF 0.67 Btu/Hr 75000 0 80 80 Altered No WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Existing HVAC System HVAC System1 Heating and cooling system other Heating Component 1 1 Cooling Component 1 1 HVAC Fan 1 Air Distribution System 1 n/a Existing No HVAC - HEATING UNIT TYPES 01 02 03 04 05 Name System Type Number of Units Heating Efficiency Heating Unit Brand Heating Component 1 Central gas furnace 1 AFUE - 80 n/a HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:2037 S Garnsey St Calculation Date/Time:2024-10-11T09:56:27-07:00 (Page 9 of 10) Calculation Description:Title 24 Analysis Input File Name:24-964.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-11   09:57:06 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Status Verified Existing Condition Existing Distribution system New Ducts >= 25 ftSuppl y Retur n Suppl y Retur n Suppl y Retur n Air Distribution System 1 Unconditio ned attic Non- Verified R-8 R-8 Atti c Atti c n/a n/a No Bypass Duct Existing (not specified) Air Distribution System 1-hers-dist Existing No n/a HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.58 n/a PROJECT NOTES CF1R's that do not require HERS Verification are not required to be registered to a HERS provider. HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:2037 S Garnsey St Calculation Date/Time:2024-10-11T09:56:27-07:00 (Page 10 of 10) Calculation Description:Title 24 Analysis Input File Name:24-964.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-11   09:57:06 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Robert Gonzales Design 4 Building 7755 Center Ave Huntington Beach , Ca 92648 562-981-4890 10/11/2024 Carlos a. Zevallos Zevallos Design 12936 Sandy LN. Downey, Ca 90242 563-659-2066 HOLD - 2037 S Garnsey St & #24/10/2025 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type  Single Family  Addition Alone Date  Multi Family  Existing+ Addition/Alteration Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Units INSULATION Area Construction Type Cavity (ft2) Special Features Status FENESTRATION Total Area: Glazing Percentage: New/Altered Average U-Factor: Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Existing 1,315 Page 12 of 14 10/11/2024 none 13.2% Existing Addition Wall Wood Framed Attic Floor R 15 Wood Framed w/Crawl Space none none 4 N/A 159 194 n/a CA Climate Zone 08 - no insulation - Right (S) 52.0 Rear (E) 1.190 16.0 1 1.190 Small Storage Gas 0.83 Existing 1 Existing 4 HVAC System Ducted Wall Opaque Door Wall - no insulation - Wood Framed - no insulation - 1,315 - no insulation - Existing Existing 1.190 0.83 none 1,474 none 50 N/A 0.67 Existing Existing Left (N)49.0 - no insulation - Ducted 14.0 SEER 21 Existing 215 Wall Wood Framed none none 1 none Gas Central Furnace Standard N/A Left (N) New Front (W)44.0 0.300 n/a 0.23 Altered 284 Existing New Door Wood Framed Wall R 11 Wood Framed 2037 S Garnsey St Santa Ana 60 303 N/A Existing 80% AFUE 0.30 No Cooling User Number: 20180 none33.0 1.190 0.83 none 0.83 N/A Setback Existing Existing Roof ID: 24-964 - no insulation - Wood Framed EnergyPro 9.3 by EnergySoft 264 HOLD - 2037 S Garnsey St & #24/10/2025 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type  Single Family  Addition Alone Date  Multi Family  Existing+ Addition/Alteration Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Units INSULATION Area Construction Type Cavity (ft2) Special Features Status FENESTRATION Total Area: Glazing Percentage: New/Altered Average U-Factor: Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status New Page 13 of 14 10/11/2024 13.2% Addition 4 159 194 CA Climate Zone 08 - no insulation - New 1 4 Demising Wood Framed w/Crawl Space Roof - no insulation - Wood Framed Attic R 30 1,474 R 19 159 Existing 71 Demising Wood Framed 159 New Floor Wall Wood Framed 2037 S Garnsey St Santa Ana 80 0.30 User Number: 20180 Existing ID: 24-964 R 15 Wood Framed EnergyPro 9.3 by EnergySoft 100 Add=R-19.0 HOLD - 2037 S Garnsey St & #24/10/2025 BUILDING ENERGY ANALYSIS REPORT PROJECT: Project Designer: Report Prepared by: Job Number: Date: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2022 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC – www.energysoft.com. 12936 Sandy LN. Zevallos Design Downey, Ca 90242 563-659-2066 2037 S Garnsey St ADU Conversion Santa Ana, Ca 92707 7755 Center Ave Design 4 Building Robert Gonzales Huntington Beach , Ca 92648 562-981-4890 24-095 1/23/2024 HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:2037 S Garnsey St ADU Calculation Date/Time:2024-01-23T13:47:34-08:00 (Page 1 of 8) Calculation Description:Title 24 Analysis Input File Name:24-095.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-23   13:47:57 GENERAL INFORMATION 01 Project Name 2037 S Garnsey St ADU 02 Run Title Title 24 Analysis 03 Project Location 2037 S Garnsey St 04 City Santa Ana 05 Standards Version 2022 06 Zip code 92707 07 Software Version EnergyPro 9.2 08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)270 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed Addition 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft2)372 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2)1333 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)1705 19 Glazing Percentage (%)16.13% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type Natural gas 23 No Dwelling Unit:No ADDITION ALONE - Project Analysis Parameters 01 02 03 04 05 06 Existing Area (excl. new addition) (ft2) Addition Area (excl. existing) (ft2)Total Area (ft2)Existing Bedrooms Addition Bedrooms Total Bedrooms 1333 372 1705 3 1 4 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 Building does not incorporate Special Features 424-P010013492A-000-000-0000000-0000 01/23/2024 13:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:2037 S Garnsey St ADU Calculation Date/Time:2024-01-23T13:47:34-08:00 (Page 2 of 8) Calculation Description:Title 24 Analysis Input File Name:24-095.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-23   13:47:57 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0 0.3 0 0.36 0 -0.06 Space Cooling 0 41.96 0 45.04 0 -3.08 IAQ Ventilation 0 0 0 0 0 0 Water Heating 0 75.75 0 70.24 0 5.51 Self Utilization/Flexibility Credit Efficiency Compliance Total 0 118.01 0 115.64 0 2.37 Photovoltaics 0 0 Battery 0 Flexibility Indoor Lighting 0 6.86 0 6.86 Appl. & Cooking 0 84.91 0 84.82 Plug Loads 0 98.84 0 98.84 Outdoor Lighting 0 7.58 0 7.58 TOTAL COMPLIANCE 0 316.2 0 313.74 424-P010013492A-000-000-0000000-0000 01/23/2024 13:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:2037 S Garnsey St ADU Calculation Date/Time:2024-01-23T13:47:34-08:00 (Page 3 of 8) Calculation Description:Title 24 Analysis Input File Name:24-095.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-23   13:47:57 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 54.11 52.75 1.36 2.51 Net EUI2 54.11 52.75 1.36 2.51 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •NO SPECIAL FEATURES REQUIRED HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Kitchen range hood •Verified Refrigerant Charge •Verified heat pump rated heating capacity ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Zone 1 Conditioned HVAC System1 372 8 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg)Wall Exceptions Status Front Wall Zone 1 R-15 Wall 270 Front 144 39 90 Ex. w/ Siding New 424-P010013492A-000-000-0000000-0000 01/23/2024 13:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:2037 S Garnsey St ADU Calculation Date/Time:2024-01-23T13:47:34-08:00 (Page 4 of 8) Calculation Description:Title 24 Analysis Input File Name:24-095.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-23   13:47:57 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg)Wall Exceptions Status Left Wall Zone 1 R-15 Wall 0 Left 160 12 90 Ex. w/ Siding New Rear Wall Zone 1 R-15 Wall 90 Back 144 12 90 Ex. w/ Siding New Right Wall Zone 1 R-15 Wall 180 Right 160 18 90 Ex. w/ Siding New Roof Zone 1 R-30 Roof Attic n/a n/a 372 n/a n/a New ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Zone 1 Attic RoofZone 1 Ventilated 4 0.1 0.85 Yes No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Windows Window Front Wall Front 270 1 18 0.3 NFRC 0.23 NFRC Bug Screen Windows 2 Window Left Wall Left 0 1 12 0.3 NFRC 0.23 NFRC Bug Screen Windows 3 Window Rear Wall Back 90 1 12 0.3 NFRC 0.23 NFRC Bug Screen Windows 4 Window Right Wall Right 180 1 18 0.3 NFRC 0.23 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor Door Front Wall 21 0.2 424-P010013492A-000-000-0000000-0000 01/23/2024 13:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:2037 S Garnsey St ADU Calculation Date/Time:2024-01-23T13:47:34-08:00 (Page 5 of 8) Calculation Description:Title 24 Analysis Input File Name:24-095.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-23   13:47:57 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab Zone 1 372 76 none 0 80%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco Attic RoofZone 1 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 R-30 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032 Over Ceiling Joists: R-20.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a 424-P010013492A-000-000-0000000-0000 01/23/2024 13:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:2037 S Garnsey St ADU Calculation Date/Time:2024-01-23T13:47:34-08:00 (Page 6 of 8) Calculation Description:Title 24 Analysis Input File Name:24-095.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-23   13:47:57 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1) WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name Heating Element Type Tank Type # of Units Tank Vol. (gal) Heating Efficiency Type Efficiency Rated Input Type Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff 1st Hr. Rating or Flow Rate Tank Location DHW Heater 1 Gas Consumer Instantaneo us 1 0 UEF 0.9 Btu/Hr 200000 0 n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC System1 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 n/a n/a Setback 424-P010013492A-000-000-0000000-0000 01/23/2024 13:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:2037 S Garnsey St ADU Calculation Date/Time:2024-01-23T13:47:34-08:00 (Page 7 of 8) Calculation Description:Title 24 Analysis Input File Name:24-095.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-23   13:47:57 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 Ductless MiniSplit HP 1 HSPF 9.5 18000 16000 EERSEER 17 12.5 Not Zonal Single Speed Heat Pump System 1-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Not Required 0 Not Required Not Required Yes No Yes Yes 424-P010013492A-000-000-0000000-0000 01/23/2024 13:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HOLD - 2037 S Garnsey St & #24/10/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:2037 S Garnsey St ADU Calculation Date/Time:2024-01-23T13:47:34-08:00 (Page 8 of 8) Calculation Description:Title 24 Analysis Input File Name:24-095.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-23   13:47:57 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Robert Gonzales Design 4 Building 01/23/2024 7755 Center Ave. Suite 1100 Huntington Beach , CA 92648 562-981-4890 Robert Gonzales Design 4 Building 01/23/2024 7755 Center Ave. Suite 1100 Huntington Beach , CA 92648 562-981-4890 424-P010013492A-000-000-0000000-0000 01/23/2024 13:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. HOLD - 2037 S Garnsey St & #24/10/2025 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type  Single Family  Addition Alone Date  Multi Family  Existing+ Addition/Alteration Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Units INSULATION Area Construction Type Cavity (ft2) Special Features Status FENESTRATION Total Area: Glazing Percentage: New/Altered Average U-Factor: Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status ADU Conversion 2037 S Garnsey St Santa Ana Wood Framed 1/23/2024 4 4 CA Climate Zone 08 372 1 Wood Framed Wall Door Wall Wall Wall Roof Wood Framed Opaque Door Wood Framed Wood Framed Attic 105 21 148 132 142 372 R 15 R 15 R-5 R 15 R 15 R 30 New New New New New Existing 372 Front (W) Left (N) Rear (E) Right (S) 18.0 12.0 12.0 18.0 0.300 0.300 0.300 0.300 0.23 0.23 0.23 0.23 none none none none none none none none N/A N/A N/A N/A New New New New 17.0 SEER1Electric Heat Pump Split Heat Pump9.50 HSPF NewSetback n/aHVAC System DuctlessDuctless / with Fan Newn/a Standard1Small Instantaneous Gas 0.900 New ID: 24-095 Page 10 of 11EnergyPro 9.2 by EnergySoft User Number: 20180 Unheated Slab-on-GradeSlab 372- no insulation -ExistingPerim = 76' 60 16.1%0.30 HOLD - 2037 S Garnsey St & #24/10/2025 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date System Name Floor Area ENGINEERING CHECKS SYSTEM LOAD Number of Systems COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System Total Room Loads Total Output (Btuh) Return Vented Lighting Output (Btuh/sqft) Return Air Ducts Cooling System Return Fan Output per System Ventilation Total Output (Btuh) Supply Fan Total Output (Tons) Supply Air Ducts Total Output (Btuh/sqft) Total Output (sqft/Ton) TOTAL SYSTEM LOAD Air System CFM per System HVAC EQUIPMENT SELECTION Airflow (cfm) Airflow (cfm/sqft) Airflow (cfm/Ton) Outside Air (%) Total Adjusted System Output Outside Air (cfm/sqft) (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) ADU Conversion 1/23/2024 HVAC System 372 1 18,000 18,000 48.4 18,000 18,000 1.5 48.4 248.0 600 600 1.61 400.0 0.0% 0.00 0 3,311 0 0 0 921 0 0 5,633 0 -921 00 0 0 0 3,53813,216 1804,232 13,216 13,448 3,538 13,448 1.5 Mini Split Unit Aug 3 PM Jan 1 AM 166 180 136 33 ºF Outside Air 0 cfm 68 ºF 105 ºF 106 ºF 106 ºF 68 ºF 68 ºF 91 / 68 ºF 75 / 61 ºF 55 / 54 ºF 56 / 54 ºF 75 / 61 ºF75 / 61 ºF 0 cfm Outside Air 600 cfm Supply Fan 45.8% 600 cfm Supply FanHeating Coil 4,712 56 / 54 ºF Cooling Coil HOLD - 2037 S Garnsey St & #24/10/2025 HOLD - 2037 S Garnsey St & #24/10/2025 HOLD - 2037 S Garnsey St & #24/10/2025 CIVIL LAND ENGINEERS 12109 Woodruff Ave. Downey, CA 90241 PHONE: 562 622 6927 PROJECT: 2037 S Garnsey St. Santa Ana, CA 92707 DESCRIPTION: GARAGE CONVERSION INTO ADU Job No.: 008-0723 January 22, 2024 CLIENT: Elvia Lopez 2037 S Garnsey St. Santa Ana, CA 92707 HOLD - 2037 S Garnsey St & #24/10/2025 CODE: Design based on 2022 CBC, 2023 LABC, ASCE 7-22, ACI318-20 MATERIALS: - WOOD: DOUGLAS FIR-LARCH RAFTERS, FLOOR JOIST: # 2 GRADE HEADERS, BEAMS, POSTS: # 1 GRADE UNLESS NOTED OTHERWISE (UNO). - CONCRETE: F’c = 2500 PSI (MIN.) @ 28 DAYS. - REINFORCING STEEL: ASTM A615, GRADE 40(MIN.); Fy = 40,000 PSI (MIN.) SOIL PRESSURE: 1500 PSF (Per 2022 CBC) LOADS ROOF PSF INTERIOR WALL PSF Roofing 6.0 Framing (2 x 4 @ 16”) 2.0 Plywood (1/2 “) 1.7 Drywall (2 sides) 5.0 Framing 2.9 Miscellaneous 3.0 Miscellaneous 1.4 TOTAL DL = 10 PSF TOTAL DL = 12 PSF ROOF LL (4:12 slope) = 20 PSF CEILING PSF EXTERIOR WALL PSF Framing 6.0 Drywall 2.5 Framing (2 x 4 @ 16”) 2.0 Miscellaneous 1.0 Stucco 10.0 TOTAL DL = 10.0 PSF Plywood (1/2”) 1.5 TOTAL LL = 10.0 PSF Drywall (1 side) 2.5 Miscellaneous(ins. etc) 2.0 TOTAL DL = 18 PSF HOLD - 2037 S Garnsey St & #24/10/2025 Level Member Name Results (Max UTIL %)Current Solution Comments Roof Rafters Design Passed (26% M)1 piece(s) 2 x 6 DF No.2 @ 16" OC Ceiling Joists Design Passed (75% ΔT)1 piece(s) 2 x 6 DF No.2 @ 16" OC Roof Beams Design at Patio Covered Passed (93% R)1 piece(s) 5 1/4" x 11 7/8" 2.0E Parallam® PSL Ridge Beam Design (Addition)Passed (93% M)1 piece(s) 4 x 10 DF No.1 Header Design (Addition)Passed (75% M)1 piece(s) 4 x 8 DF No.1 Ceiling Beam Design (Addition)Passed (71% ΔT)1 piece(s) 3 1/2" x 9 1/2" 2.0E Parallam® PSL Ceiling Joists Design (ADU)Passed (90% M)1 piece(s) 2 x 8 DF No.2 @ 16" OC Garnsey St - 01.24 JOB SUMMARY REPORT ForteWEB Software Operator Job Notes 9/25/2024 6:32:24 AM UTC Carlos A Zevallos Zevallos Design (562) 659-2066 zevallos.design@aol.com ForteWEB v3.8 File Name: Garnsey St - 01.24 Page 1 / 8 HOLD - 2037 S Garnsey St & #24/10/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)155 @ 8' 4 1/2"1406 (1.50")Passed (11%)--1.0 D + 1.0 Lr (Alt Spans) Shear (lbs)136 @ 1' 8 11/16"1238 Passed (11%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)275 @ 4' 9 7/8"1060 Passed (26%)1.25 1.0 D + 1.0 Lr (Alt Spans) Live Load Defl. (in)0.053 @ 4' 9 5/16"0.381 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.086 @ 4' 9 3/8"0.508 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) Member Length : 8' 11 3/4" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 4/12 •Deflection criteria: LL (L/240) and TL (L/180). •Overhang deflection criteria: LL (2L/240) and TL (2L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Beveled Plate - SPF 3.50"3.50"1.50"82 129 211 Blocking 2 - Hanger on 5 1/2" SPF beam 1.50"Hanger¹1.50"61 99 160 See note ¹ •Maximum allowable bracing intervals based on applied load. •Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' 10" o/c Bottom Edge (Lu)8' 10" o/c Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LRU26Z 1.94"N/A 4-10dx1.5 5-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Roof Live Vertical Load Location (Side)Spacing (0.90)(1.25)Comments 1 - Uniform (PSF)0 to 8' 6"16"12.0 20.0 Roof Loads Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, Roof Rafters Design 1 piece(s) 2 x 6 DF No.2 @ 16" OC ForteWEB Software Operator Job Notes 9/25/2024 6:32:24 AM UTC Carlos A Zevallos Zevallos Design (562) 659-2066 zevallos.design@aol.com ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: Garnsey St - 01.24 Page 2 / 8 HOLD - 2037 S Garnsey St & #24/10/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)243 @ 2 1/2"2231 (3.50")Passed (11%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)215 @ 9"1238 Passed (17%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)739 @ 6' 6"1060 Passed (70%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.226 @ 6' 6"0.629 Passed (L/668)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.633 @ 6' 6"0.839 Passed (L/239)--1.0 D + 1.0 Lr (All Spans) Member Length : 13' System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Beam - SPF 3.50"3.50"1.50"156 87 243 Blocking 2 - Beam - SPF 3.50"3.50"1.50"156 87 243 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)9' 10" o/c Bottom Edge (Lu)13' o/c Dead Roof Live Vertical Load Location (Side)Spacing (0.90)(1.25)Comments 1 - Uniform (PSF)0 to 13'16"18.0 10.0 Ceiling Loads Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, Ceiling Joists Design 1 piece(s) 2 x 6 DF No.2 @ 16" OC ForteWEB Software Operator Job Notes 9/25/2024 6:32:24 AM UTC Carlos A Zevallos Zevallos Design (562) 659-2066 zevallos.design@aol.com ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: Garnsey St - 01.24 Page 3 / 8 HOLD - 2037 S Garnsey St & #24/10/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4587 @ 3 1/2"4922 (1.50")Passed (93%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)4123 @ 1' 3 3/8"15066 Passed (27%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)22411 @ 10' 3/4"37317 Passed (60%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.419 @ 10' 3/4"0.977 Passed (L/560)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)1.093 @ 10' 3/4"1.303 Passed (L/215)--1.0 D + 1.0 Lr (All Spans) Member Length : 19' 8 1/2" System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Hanger on 11 7/8" SPF Ledger 3.50"Hanger¹1.50"2907 1811 4719 See note ¹ 2 - Column Cap - steel 3.50"3.50"1.50"2877 1789 4666 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)19' 9" o/c Bottom Edge (Lu)19' 9" o/c Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger Connector not found N/A N/A N/A N/A •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)3 1/2" to 20'N/A 19.5 -- 1 - Uniform (PSF)0 to 20' (Front)9'12.0 20.0 Roof Load 2 - Uniform (PSF)0 to 20' (Front)9'18.0 -Ceiling Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, Roof Beams Design at Patio Covered 1 piece(s) 5 1/4" x 11 7/8" 2.0E Parallam® PSL ForteWEB Software Operator Job Notes 9/25/2024 6:32:24 AM UTC Carlos A Zevallos Zevallos Design (562) 659-2066 zevallos.design@aol.com ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: Garnsey St - 01.24 Page 4 / 8 HOLD - 2037 S Garnsey St & #24/10/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1622 @ 2"7656 (3.50")Passed (21%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)1392 @ 1' 3/4"4856 Passed (29%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)5813 @ 7' 6"6239 Passed (93%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.345 @ 7' 6"0.733 Passed (L/510)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.574 @ 7' 6"0.978 Passed (L/307)--1.0 D + 1.0 Lr (All Spans) Member Length : 15' System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Column Cap - steel 3.50"3.50"1.50"647 975 1622 Blocking 2 - Column Cap - steel 3.50"3.50"1.50"647 975 1622 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)15' o/c Bottom Edge (Lu)15' o/c • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)0 to 15'N/A 8.2 -- 1 - Uniform (PSF)0 to 15' (Front)6' 6"12.0 20.0 Roof Loads Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, Ridge Beam Design (Addition) 1 piece(s) 4 x 10 DF No.1 ForteWEB Software Operator Job Notes 9/25/2024 6:32:24 AM UTC Carlos A Zevallos Zevallos Design (562) 659-2066 zevallos.design@aol.com ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: Garnsey St - 01.24 Page 5 / 8 HOLD - 2037 S Garnsey St & #24/10/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)829 @ 0 3281 (1.50")Passed (25%)--1.0 D (All Spans) Shear (lbs)824 @ 8 3/4"2741 Passed (30%)0.90 1.0 D (All Spans) Moment (Ft-lbs)2255 @ 2' 9"2989 Passed (75%)0.90 1.0 D (All Spans) Live Load Defl. (in)0.000 @ 0 0.183 Passed (2L/999+)--1.0 D (All Spans) Total Load Defl. (in)0.052 @ 2' 9"0.275 Passed (L/999+)--1.0 D (All Spans) Member Length : 5' 6" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Factored Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"829 829 None 2 - Trimmer - SPF 1.50"1.50"1.50"829 829 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)5' 6" o/c Bottom Edge (Lu)5' 6" o/c Dead Vertical Loads Location Tributary Width (0.90)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 6.4 1 - Point (lb)2' 9"N/A 1622 Point Load from Ridge Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, Header Design (Addition) 1 piece(s) 4 x 8 DF No.1 ForteWEB Software Operator Job Notes 9/25/2024 6:32:24 AM UTC Carlos A Zevallos Zevallos Design (562) 659-2066 zevallos.design@aol.com ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: Garnsey St - 01.24 Page 6 / 8 HOLD - 2037 S Garnsey St & #24/10/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2623 @ 2"4922 (2.25")Passed (53%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)2346 @ 1' 1"8035 Passed (29%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)8212 @ 6' 6"11751 Passed (70%)0.90 1.0 D (All Spans) Live Load Defl. (in)0.160 @ 6' 6"0.633 Passed (L/952)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.603 @ 6' 6"0.844 Passed (L/252)--1.0 D + 1.0 Lr (All Spans) Member Length : 12' 9 1/2" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Column Cap - steel 3.50"2.25"1.50"1807 845 2652 1 1/4" Rim Board 2 - Column Cap - steel 3.50"2.25"1.50"1807 845 2652 1 1/4" Rim Board •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)12' 10" o/c Bottom Edge (Lu)12' 10" o/c • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)1 1/4" to 12' 10 3/4"N/A 10.4 -- 1 - Uniform (PSF)0 to 13' (Front)6' 6"12.0 20.0 Roof Loads 2 - Uniform (PSF)0 to 13' (Front)6' 6"10.0 -Ceiling Loads 3 - Point (lb)6' 6" (Top)N/A 1622 -Ridge Beam Point Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, Ceiling Beam Design (Addition) 1 piece(s) 3 1/2" x 9 1/2" 2.0E Parallam® PSL ForteWEB Software Operator Job Notes 9/25/2024 6:32:24 AM UTC Carlos A Zevallos Zevallos Design (562) 659-2066 zevallos.design@aol.com ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: Garnsey St - 01.24 Page 7 / 8 HOLD - 2037 S Garnsey St & #24/10/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)244 @ 2 1/2"2231 (3.50")Passed (11%)--1.0 D + 1.0 L (All Spans) Shear (lbs)221 @ 10 3/4"1305 Passed (17%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1070 @ 9' 2"1183 Passed (90%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.406 @ 9' 2"0.896 Passed (L/530)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.811 @ 9' 2"1.194 Passed (L/265)--1.0 D + 1.0 L (All Spans) Member Length : 18' 4" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor/Ceiling Live Factored Accessories 1 - Stud wall - SPF 3.50"3.50"1.50"122 122 244 Blocking 2 - Stud wall - SPF 3.50"3.50"1.50"122 122 244 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)6' 7" o/c Bottom Edge (Lu)18' 4" o/c • Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. Dead Floor/Ceiling Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 18' 4"16"10.0 10.0 Ceiling Loads Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, Ceiling Joists Design (ADU) 1 piece(s) 2 x 8 DF No.2 @ 16" OC ForteWEB Software Operator Job Notes 9/25/2024 6:32:24 AM UTC Carlos A Zevallos Zevallos Design (562) 659-2066 zevallos.design@aol.com ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: Garnsey St - 01.24 Page 8 / 8 HOLD - 2037 S Garnsey St & #24/10/2025 6/8/2021 U.S. Seismic Design Maps https://seismicmaps.org 1/2 New One Story ADU Latitude, Longitude: 33.720, -117.875 Date 6/8/2021, 4:14:43 PM Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Default (See Section 11.4.3) Type Value Description SS 1.284 MCER ground motion. (for 0.2 second period) S1 0.46 MCER ground motion. (for 1.0s period) SMS 1.541 Site-modified spectral acceleration value SM1 null -See Section 11.4.8 Site-modified spectral acceleration value SDS 1.028 Numeric seismic design value at 0.2 second SA SD1 null -See Section 11.4.8 Numeric seismic design value at 1.0 second SA Type Value Description SDC null -See Section 11.4.8 Seismic design category Fa 1.2 Site amplification factor at 0.2 second Fv null -See Section 11.4.8 Site amplification factor at 1.0 second PGA 0.545 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.654 Site modified peak ground acceleration TL 8 Long-period transition period in seconds SsRT 1.284 Probabilistic risk-targeted ground motion. (0.2 second) SsUH 1.384 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 1.676 Factored deterministic acceleration value. (0.2 second) S1RT 0.46 Probabilistic risk-targeted ground motion. (1.0 second) S1UH 0.496 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration. S1D 0.6 Factored deterministic acceleration value. (1.0 second) PGAd 0.686 Factored deterministic acceleration value. (Peak Ground Acceleration) CRS 0.928 Mapped value of the risk coefficient at short periods CR1 0.926 Mapped value of the risk coefficient at a period of 1 s HOLD - 2037 S Garnsey St & #24/10/2025 6/8/2021 U.S. Seismic Design Maps https://seismicmaps.org 2/2 DISCLAIMER While the information presented on this website is believed to be correct, SEAOC /OSHPD and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in this web application should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. SEAOC / OSHPD do not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the seismic data provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the search results of this website. HOLD - 2037 S Garnsey St & #24/10/2025 LATERAL ANALYSIS: (SEISMIC DESIGN FACTORS AND BASE SHEAR) FAULT NAME: NEWPORT/INGLEWOOD FAULT THE FOLLOWING SEISMIC FACTORS APPLY: - CLOSEST DISTANCE TO KNOWN SEISMIC SOURCE = > 10 Km Per Book Of Faults - STRUCTURAL SYSTEM: WOOD LIGHT- FRAME WALLS WITH SHEAR PANEL OF ALL OTHER MATERIAL COORDINATES: MAPPED SPECTRAL RESPONSE ACCELERATIONS (from earthquake.usgs.gov/research/hazmaps/design/index.php and Java Ground Motion Parameter Calculator, Version 5.0.8) Ss = 1.284 Latitude: 33°43’11.690” ~ 33.720 (Per Google Earth) S1 = 0.460 Longitude: 117°52’30.60” ~ -117.875 (Per Google Earth) RISK CATEGORY AND FACTOR (CBC Table 1604.5): Category II I = 1.00 SITE CLASS: Class “D” (per Table 1613.5.2) SEISMIC CATEGORY (CBC 1613.5.6) Occupancy Categories I, II or III, if S1 is greater than or equal to 0.75, Seismic Category “D” shall be used (per CBC Section 1613.5.6). SITE CLASS COEFFICIENTS (Table 1613.5.3 (1) & (2): Fa = 1.2 (for Ss≥1.25) Fv = 1.80 (for S1≥0.5) 5% DAMPED SPECTRAL RESPONSE ACCELERATION ADJUSTED FOR SITE CLASS: SMS = Fa x Ss SMS = 1.2 x 1.284 = 1.541 SM1 = Fv x S1 SM1 = 1.8 x 0.460 = 0.828 DESIGN SPECTRAL RESPONSE ACCELERATIONS: SDS = (2/3)xSMS (per Equation 16-39) SDS = (2/3) x 1.541 = 1.028 SD1 = (2/3)xSM1 (per Equation 16-40) SD1 = (2/3) x 0.828 = 0.552 HOLD - 2037 S Garnsey St & #24/10/2025 FUNDAMENTAL SITE PERIODS To AND Ts: To = 0.2 x (SD1/SDS) To = 0.2 x (0.552/1.028) = 0.107 Ts = (SD1/SDS) Ts = (0.552/1.028) = 0.537 BUILDING PERIOD (ASCE-07-10 Table 12.8-2): Ct = 0.02 x = 0.75 Building Height, average (ft): h = 8’ T = Ct x hx = 0.02 x 80.75 = 0.095 DESIGN SPECTRAL RESPONSE ACCELERATION, Sa: Sa1 = SDS x (0.4 + 0.6 x (T/To) Sa1 = 0.959 Sa2 = SDS Sa2 = 1.028 Sa3 = if (T < To, Sa1, Sa2) Sa3 = 0.959 Sa4 = SD1/T Sa4 = 5.811 Sa = if (T > Ts, Sa4, Sa3) Sa = 0.959 DESIGN COEFFICIENTS (ASCE-07-10 Table 12-2-1) R = 6.5 Ω = 3.0 Cd = 4.0 BASE SHEAR: CS1 = SDS/(R/I) CS1 = 0.158 CS2 = SD1/(T x (R/I) CS2 = 0.894 Cs3 = if (T ≤ Ts, Cs1, Cs2) Cs3 = 0.158 CSmin = 0.5S1/(R/I) CSmin = 0.042 Cs = if (CS3 > Csmin., Cs3, Csmin) Cs3 = 0.158 Cs = 0.158 ρ = 1.30 per Section 12.3.3.4 & 12.8.1 V = Cs x W V = 1.30 x 0.158 W V = 0.205 W HOLD - 2037 S Garnsey St & #24/10/2025 LATERAL ANALISIS: DEAD LOAD AT ROOF: ROOF : 12.0 psf CEILING __________________: 10.0 psf INTERIOR WALL________________: 10.0 psf EXT. WALL = 18 psf x 8’/2 x 2 : 7.86 psf 18.33’ 39.86 psf SEISMIC LOAD = 0.205 x 69.86 psf = 8.17 psf ROOF DIAPHRAGM: SHEAR = 8.17 psf x 18.33’ x 20.17’ = 82 lbs < 280 x 0.75 = 210 lbs FT 2 x 18.33’ ft ft USE: 15/32” OSB PLYWOOD WITH RADIANT BARRIER AND WITH W/8d COMMON NAILS AT 6,6,12 O.C. CHORD: F = (8.17 psf x 18.33’) x 20.17’2 x 1 = 415 lbs 8 18.33’ ft TRY: 2x4 IN TENSIÓN - CAPACITY = 675 psi x 1.5 x 3.5 = 3,544 lbs/ft > 415 lbs/ft OK (per NDS Table 4A) USE: 2 – 2 x 4 TOP PLATES W/ LSTA30 AT LAP PLATES HOLD - 2037 S Garnsey St & #24/10/2025 LINES 1 & 2: SEISMIC FORCE = 0.205 [(22 psf x 18.33’ x 20.17’/2)+ (18 psf x 10.09’ x 4’x 2) + (10 psf x 10.09’ x 4’)] = 5,926 lbs SEISMIC FORCE = 0.205 x 5926 = 1,215 lbs GOVERNS WIND FORCE = 22.35 psf (10.09’ x 6’) = 1353 lbs  SHEAR = 1215 lbs = 202 lbs < 430 x 0.75 = 323 lbs FT 6’ ft ft ft USE: SHEAR WALL TYPE “A” (PER SHEAR WALL SCHEDULE ON S-1) SPACING OF A 35’ s REQUIRED: ANCHOR BOLTS: 408 x 1.3 = 2.63’ 202 450 = 2.22’ ~ 24” 202 USE: 5/8” DIAM x 12” LONG @ 30” O.C USE: A35 @ 24” O.C. CHECK UPLIFT: Fr = 1215 lbs ROOF DL = 12 PSF x (6’ x 4’/2) = 144 lbs CEILING DL = 10 PSF x (6’ x 2.67’/2) = 80 lbs WALL DL = 18 PSF x 6’ x 8’ = 864 lbs TOTAL W = 1088 x 0.60 = 653 lbs F=653 6’ TAKE MOMENTS ABOUT POINT O: 653 (8’) – T (6’) – 653 (6’/2) = 0 8’ W T = 5224 – 1959 (6’ – 0.5’) O T T = 594 lbs < 3075 x 0.75 = 2,306 lbs USE: HDU2-SDS2.5 SIMPSON HOLDOWN WITH SSTB16 ANCHOR AT EACH 4X4 POST AT NEW FOOTING HOLD - 2037 S Garnsey St & #24/10/2025 LINES A & B: SEISMIC FORCE = 0.205 [(22 psf x 20.17’ x 18.33’/2)+ (18 psf x 9.17’ x 4’x 2) + (10 psf x 9.17’ x 4’)] = 5,756 lbs SEISMIC FORCE = 0.205 x 5756 = 1,180 lbs GOVERNS WIND FORCE = 22.35 psf (9.17’ x 6’) = 1129 lbs  SHEAR = 1180 lbs = 124 lbs < 430 x 0.75 = 323 lbs FT 9.5’ ft ft ft USE: SHEAR WALL TYPE “A” (PER SHEAR WALL SCHEDULE ON S-1) SPACING OF A 35’ s REQUIRED: ANCHOR BOLTS: 408 x 1.3 = 4.27’ 124 450 = 3.63’ ~ 24” 124 USE: 5/8” DIAM x 12” LONG @ 30” O.C USE: A35 @ 24” O.C. CHECK UPLIFT: Fr = 1180 lbs ROOF DL = 12 PSF x (9.5’ x 4’/2) = 228 lbs CEILING DL = 10 PSF x (9.5’ x 18’/2) = 855 lbs WALL DL = 18 PSF x 9.5’ x 8’ = 1368 lbs TOTAL W = 2451 x 0.60 = 1470 lbs F=1180 9.5’ TAKE MOMENTS ABOUT POINT O: 1180 (8’) – T (9.5’) – 1470 (9.5’/2) = 0 8’ W T = 9440 – 6985 (9.5’ – 0.5’) O T T = 272 lbs < 3075 x 0.75 = 2,306 lbs USE: HDU2-SDS2.5 SIMPSON HOLDOWN WITH SSTB16 ANCHOR AT EACH 4X4 POST AT NEW FOOTING HOLD - 2037 S Garnsey St & #24/10/2025 AT PATIO COVERED: 1.028/1.25 = 0.82 X 1.3 = 1.066 SEISMIC FORCE = 1.066 psf (22 psf x 20’ x 15’/2) = 3518 lbs GOVERNS WIND FORCE = 22.80 PSF x 5.63’ x 8’ = 1006 lbs SEISMIC FORCE PER FRAME ⇒ 3518/2 = 1759 lbs 24” V V = 1759 lbs TAKE MOMENTS ABOUT POINT A: 24” 8’(1759) – 6’H = 0 ⇒ H = 2345 lbs F H ⇒ F = 2345 x 1.41 = 2536 lbs TRY: 6 x 6 No.1 KNEE BRACE WITH 6” x 6” POST W/1- 1” Ø BOLT AT 6’ EACH END BRACE (FROM N.D.S. PAGE 60) AT SINGLE SHEAR = 2660 lbs) A NUMBER OF BOLTS REQ’D = 2536 = 0.95 USE: 1 – 1” BOLT 2660 USE: 6 x 6 No.1 KNEE BRACE WITH 6”x 6” # 1 POST WITH 1 – 1” DIA. LAG BOLTS AT BEAM AND 1” DIA. BOLT AT POST. PAD FOOTING DESIGN - AREA REQ’D AT: P-1 = 2352 X 2 = √3.13 sq.ft ~ 2’ SQ. x 24” DEEP (R=2237 lbs from Ridge Beams) 1500 HOLD - 2037 S Garnsey St & #24/10/2025