HomeMy WebLinkAbout2605 W Strawberry Ln #2 - 101118650 - PlanSHEET INDEX PROPERTY INFO CONSULTANTS BUILDING DATA BUILDING CODES LOT COVERAGE ARCHITECTURAL DRAWINGS STRUCTURAL DRAWINGS VICINITY MAP SCOPE OF WORK STRAWBERRY RESIDENCE 2605 STRAWBERRY LANE #2 SANTA ANA, CA 92706 GARAGE CONVERT INTO ADU GENERAL NOTES FLOOR NOTES ROOF PLAN NOTES ABBREVIATIONS DOORS & EGRESS WINDOWS NOTES SMOKE & CARBON MONOXIDE ALARMS NOTES BUS STOP MAP “ ” “ ” SQUARE FOOTAGE RATIO T-1 TITLE SHEET SHEET NUMBER SHEETSOF REVISIONS DRAWN : CHECKED : DATE : JOB NO. MARK DATE 23-10263 GA GA 08 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U ST R A W B E R R Y R E S I D E N C E Margarito Castillo, S.E. PR O J E C T A D D R E S S : 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS TO THE C.B.C. PROJECT: ENGINEER: CASTILLO ENGINEERING 324 E SOUTH AVE. LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM Bldg# 101118650 APPROVALS PLNG- PRaj BLDG- CSG Consultants POLICE- BMartin 2605 W Strawberry Ln #2 - 1011186506/26/2024 N1SITE PLAN 4' - 0 " 4'-0" P O R C H 75 . 5 0 S Q . F T . (E ) G A R A G E C O N V E R T IN T O A D U 2 6 0 5 S T R A W B E R R Y L A N E , # 2 64 0 . 0 0 S Q . F T . 26 0 5 S T R A W B E R R Y L N (E) SINGLE FAMILY DWELLING 1,560.00 SQ.FT. 2% 5% 2% 5% 2% 5% 1 A-A SECTION2%5% AA 5%5% 2% 2% 2% 2%2%2%2% 5% 5% 2% 5% 2%2%2%2% 5% 2% 5% 2% GFCI LEGEND GAS NOTES GA S GASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGAS GAS GAS GAS GAS GAS GAS GAS A1.0 SITE PLAN SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS DRAWN : CHECKED : DATE : JOB NO. MARK DATE 23-10263 GA GA 08 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U ST R A W B E R R Y R E S I D E N C E Margarito Castillo, S.E. 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS TO THE C.B.C. PROJECT: ENGINEER: CASTILLO ENGINEERING 324 E SOUTH AVE. LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM 2605 STRAWBERRY LANE 2605 W Strawberry Ln #2 - 1011186506/26/2024 N1PROPOSED LANDSCAPE PLAN 4' - 0 " 4'-0" P O R C H 75 . 5 0 S Q . F T . (E ) G A R A G E C O N V E R T IN T O A D U 2 6 0 5 S T R A W B E R R Y L A N E , # 2 64 0 . 0 0 S Q . F T . 26 0 5 S T R A W B E R R Y L N (E) SINGLE FAMILY DWELLING 1,560.00 SQ.FT. SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS DRAWN : CHECKED : DATE : JOB NO. MARK DATE 23-10263 GA GA 08 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U ST R A W B E R R Y R E S I D E N C E Margarito Castillo, S.E. 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS TO THE C.B.C. PROJECT: ENGINEER: CASTILLO ENGINEERING 324 E SOUTH AVE. LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM A1.1 PROPOSED LANDSCAPE PLAN 2605 STRAWBERRY LANE 2605 W Strawberry Ln #2 - 1011186506/26/2024 WINDOW SCHEDULE DOOR SCHEDULE SIZEMARK REMARKSQUANTITY SIZEMARK REMARKSQUANTITY 1 DEMO PLAN LEGEND 2 FLOOR PLAN PROPOSED GFI GFI GFI AFCI AFCI AFCI AFCI AFCIAFCI AFCI AFCI GFI AFCI AFCI AFCI AFCI KEYNOTES THE KEY NOTES DIRECTLY BELOW REFER TO THE DEMO PLAN ONLY (ADU)(ADU) DEMO PLAN AND FLOOR PLAN A2.2 SHEET NUMBER SHEETSOF REVISIONS DRAWN : CHECKED : DATE : JOB NO. MARK DATE 23-10263 GA GA 08 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U ST R A W B E R R Y R E S I D E N C E Margarito Castillo, S.E. PR O J E C T A D D R E S S : 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS TO THE C.B.C. PROJECT: ENGINEER: CASTILLO ENGINEERING 324 E SOUTH AVE. LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM 2605 W Strawberry Ln #2 - 1011186506/26/2024 KEYNOTES LEGEND ATTIC VENTILATION THE KEY NOTES DIRECTLY BELOW REFER TO THE ROOF PLAN ONLY 1 ROOF PLAN SLOPE 4:12 SLOPE 4:12 SLOPE 2:12 (ADU) (EXISTING ROOF) ROOF PLAN A2.5 SHEET NUMBER SHEETSOF REVISIONS DRAWN : CHECKED : DATE : JOB NO. MARK DATE 23-10263 GA GA 08 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U ST R A W B E R R Y R E S I D E N C E Margarito Castillo, S.E. PR O J E C T A D D R E S S : 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS TO THE C.B.C. PROJECT: ENGINEER: CASTILLO ENGINEERING 324 E SOUTH AVE. LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM 2605 W Strawberry Ln #2 - 1011186506/26/2024 KEYNOTES THE KEY NOTES DIRECTLY BELOW REFER TO THE ELEVATIONS ONLY 4 1 NORTH ELEVATION 1 WEST ELEVATION 1 SOUTH ELEVATION 1 EAST ELEVATION 2 2 45 2 4 45222 6 (ADU)(ADU) (ADU)(ADU) 6.76 SQ.FT. OPENABLE AREA 44 " M A X FO R E G R E S S 7.50 SQ.FT. OPENABLE AREA ELEVATIONS A3.0 SHEET NUMBER SHEETSOF REVISIONS DRAWN : CHECKED : DATE : JOB NO. MARK DATE 23-10263 GA GA 08 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U ST R A W B E R R Y R E S I D E N C E Margarito Castillo, S.E. PR O J E C T A D D R E S S : 26 0 5 S T R A W B E R R Y L A N E , #2 SA N T A A N A , C A 9 2 7 0 6 CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS TO THE C.B.C. PROJECT: ENGINEER: CASTILLO ENGINEERING 324 E SOUTH AVE. LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM 2605 W Strawberry Ln #2 - 1011186506/26/2024 9 5 1 10 6 2 11 7 3 12 8 4 DETAILDETAILDETAILDETAIL DETAIL DETAIL DETAIL DETAIL DETAIL DETAIL DETAIL DETAIL 2 3 ®™ 2 4 4 5 1 1 ® ® ® TM GRAC E VYCO R ® enV - S ™ GRAC E VYCO R ® enV - S ™ GRAC E VYC O R ® enV - S ™ GRAC E VYCO R ® enV - S ™ ® 2 3 2 4 4 5 — GRAB BAR GRAB BAR 3 1 4 2 5 6 7 8 9 A4.0 DETAILS SHEET NUMBER SHEETSOF REVISIONS DRAWN : CHECKED : DATE : JOB NO. MARK DATE 23-10263 GA GA 08 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U ST R A W B E R R Y R E S I D E N C E Margarito Castillo, S.E. PR O J E C T A D D R E S S : 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS TO THE C.B.C. PROJECT: ENGINEER: CASTILLO ENGINEERING 324 E SOUTH AVE. LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM 2605 W Strawberry Ln #2 - 1011186506/26/2024 STRUCTURAL NOTES S1.0 SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 23-10263 JSM MC 9 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U S T R A W B E R R Y R E S I D E N C E 26 0 5 S T R A W B E R R Y L A N E , #2 SA N T A A N A , C A 9 2 7 0 6 3 1 2 3 ENGINEER: Margarito Castillo, S.E. CASTILLO ENGINEERING 324 SOUTH AVE, LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM STRUCTURAL NOTES 2605 W Strawberry Ln #2 - 1011186506/26/2024 TYPICAL DETAIL1TYPICAL DETAIL2TYPICAL DETAIL4 TYPICAL DETAIL5TYPICAL DETAIL6TYPICAL DETAIL7TYPICAL DETAIL8 TYPICAL DETAIL12 TYPICAL DETAIL11 TYPICAL DETAIL10 TYPICAL DETAIL9 TYPICAL DETAIL3 S1.1 SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 23-10263 JSM MC 9 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U S T R A W B E R R Y R E S I D E N C E 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 3 1 2 3 ENGINEER: Margarito Castillo, S.E. CASTILLO ENGINEERING 324 SOUTH AVE, LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM TYPICAL DETAILS 2605 W Strawberry Ln #2 - 1011186506/26/2024 TYPICAL DETAIL2TYPICAL DETAIL4 TYPICAL DETAIL5TYPICAL DETAIL6TYPICAL DETAIL8 TYPICAL DETAIL12 TYPICAL DETAIL9TYPICAL DETAIL10 S1.2 SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 23-10263 JSM MC 9 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U S T R A W B E R R Y R E S I D E N C E 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 3 1 2 3 ENGINEER: Margarito Castillo, S.E. CASTILLO ENGINEERING 324 SOUTH AVE, LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM TYPICAL DETAILS 2605 W Strawberry Ln #2 - 1011186506/26/2024 TYPICAL DETAIL1TYPICAL DETAIL2TYPICAL DETAIL4 TYPICAL DETAIL12 TYPICAL DETAIL11 TYPICAL DETAIL3 TYPICAL DETAIL9TYPICAL DETAIL10 S1.3 SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 23-10263 JSM MC 9 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U S T R A W B E R R Y R E S I D E N C E 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 3 1 2 3 ENGINEER: Margarito Castillo, S.E. CASTILLO ENGINEERING 324 SOUTH AVE, LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM TYPICAL DETAILS 2605 W Strawberry Ln #2 - 1011186506/26/2024 N1FOUNDATION PLAN SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 23-10263 JSM MC 9 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U S T R A W B E R R Y R E S I D E N C E 26 0 5 S T R A W B E R R Y L A N E , #2 SA N T A A N A , C A 9 2 7 0 6 3 1 2 3 ENGINEER: Margarito Castillo, S.E. CASTILLO ENGINEERING 324 SOUTH AVE, LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM S2.0 FOUNDATION PLAN 2605 W Strawberry Ln #2 - 1011186506/26/2024 N1ROOF FRAMING PLAN C.J. SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 23-10263 JSM MC 9 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U S T R A W B E R R Y R E S I D E N C E 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 3 1 2 3 ENGINEER: Margarito Castillo, S.E. CASTILLO ENGINEERING 324 SOUTH AVE, LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM S2.2 ROOF FRAMING PLAN 2605 W Strawberry Ln #2 - 1011186506/26/2024 DETAIL1DETAIL2DETAIL4 DETAIL5DETAIL6DETAIL7DETAIL8 DETAIL12 DETAIL11 DETAIL10 DETAIL9 DETAIL3 S3.0 SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 23-10263 JSM MC 9 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U S T R A W B E R R Y R E S I D E N C E 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 3 1 2 3 ENGINEER: Margarito Castillo, S.E. CASTILLO ENGINEERING 324 SOUTH AVE, LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM FOUNDATION DETAILS 2605 W Strawberry Ln #2 - 1011186506/26/2024 DETAIL1DETAIL2DETAIL4 DETAIL6DETAIL7DETAIL8 DETAIL12 DETAIL11 DETAIL3 S5.0 SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 23-10263 JSM MC 9 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U S T R A W B E R R Y R E S I D E N C E 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 3 1 2 3 ENGINEER: Margarito Castillo, S.E. CASTILLO ENGINEERING 324 SOUTH AVE, LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM ROOF FRAMING DETAILS 2605 W Strawberry Ln #2 - 1011186506/26/2024 T-2 TITLE 24 REPORT SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS DRAWN : CHECKED : DATE : JOB NO. MARK DATE 23-10263 GA GA 08 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U ST R A W B E R R Y R E S I D E N C E Margarito Castillo, S.E. 26 0 5 S T R A W B E R R Y L A N E , SA N T A A N A , C A 9 2 7 0 6 CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS TO THE C.B.C. PROJECT: ENGINEER: CASTILLO ENGINEERING 324 E SOUTH AVE. LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM 2605 W Strawberry Ln #2 - 1011186506/26/2024 T-3 TITLE 24 REPORT AND GRADING PERMIT EXEMPTION SHEET NUMBER SHEETSOF REVISIONS DRAWN : CHECKED : DATE : JOB NO. MARK DATE 23-10263 GA GA 08 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U ST R A W B E R R Y R E S I D E N C E Margarito Castillo, S.E. PR O J E C T A D D R E S S : 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS TO THE C.B.C. PROJECT: ENGINEER: CASTILLO ENGINEERING 324 E SOUTH AVE. LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM 2605 W Strawberry Ln #2 - 1011186506/26/2024 T-4 2022 CAL GREEN SHEET NUMBER SHEETSOF REVISIONS DRAWN : CHECKED : DATE : JOB NO. MARK DATE 23-10263 GA GA 08 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U ST R A W B E R R Y R E S I D E N C E Margarito Castillo, S.E. PR O J E C T A D D R E S S : 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS TO THE C.B.C. PROJECT: ENGINEER: CASTILLO ENGINEERING 324 E SOUTH AVE. LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM 2605 W Strawberry Ln #2 - 1011186506/26/2024 T-5 2022 CAL GREEN SHEET NUMBER SHEETSOF REVISIONS DRAWN : CHECKED : DATE : JOB NO. MARK DATE 23-10263 GA GA 08 MAY 24 . . . . . . . . . . . . TITLE GA R A G E C O N V E R T I N T O A D U ST R A W B E R R Y R E S I D E N C E Margarito Castillo, S.E. PR O J E C T A D D R E S S : 26 0 5 S T R A W B E R R Y L A N E , # 2 SA N T A A N A , C A 9 2 7 0 6 CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS TO THE C.B.C. PROJECT: ENGINEER: CASTILLO ENGINEERING 324 E SOUTH AVE. LONG BEACH, CA 90805 T: 562-961-5600 WWW.CASTILLOENGINEERING.COM 2605 W Strawberry Ln #2 - 1011186506/26/2024 structural calculations for STRAWBERRY RESIDENCE garage convert into adu 2605 STRAWBERRY LANE SANTA ANA, CA 92706 09-May-24 CE JOB NO. : 23-10263 S T R U C T U R A L 3 2 4 E S O U T H S T , L O N G B E A C H , C A L I F O R N I A 9 0 8 0 5 T : 5 6 2 . 9 6 1 . 5 6 0 0 W W W . C A S T I L L O E N G I N E E R I N G . C O M 2605 W Strawberry Ln #2 - 1011186506/26/2024 ARCHITECT CASTILLO ENGINEERING, INC.JOB 1205 Pine Avenue, Suite 201 Long Beach, CA 90813 ENGR. MC JOB NO. SHEET NO. DESIGN CRITERIA 1 Soil supporting footings is natural grade or engineered fill. 2 Soil allowable bearing pressure used in design_______________________________ 3 Footing shall extend_____ minimum into undisturbed soil or_____ below finish grade whichever is lower. 4 All concrete shall develop a minimum compressive strength of 2500 psi in 28 days. 5 Reinforcing steel shall conform to ASTM 615, Grade 60. 6 Structural steel shall conform to the following: Wide flange shapes ASTM A992 TS shapes ASTM A500, Grade B Pipe shapes ASTM A53 , Grade B Other rolled shapes, Bars and plates ASTM A36 7 Structural steel shall be fabricated in a shop of an approved fabricator. 8 All welding shall be done by Certified Welders. 9 Concrete Block shall conform to ASTM C90, Grade N-1. 10 Grout shall develop 2000 psi in 28 days. 11 Mortar shall be Type S and develop 1800 psi in 28 days. 12 All lumber shall be grade marked Douglas Fir. (Grading rule No. 17) Light Framing Construction Joist & Planks No. 2 Beams & Stringers No. 1 Posts & Timbers No. 1 13 Glue Laminated Timbers shall be combination No. 24F-V8. 14 Plywood shall conform to PS 1-95, Structural 1. 15 All material and workmanship shall conform to the requirements of 2019 California Building Code. 2605 W Strawberry Ln #2 - 1011186506/26/2024 2605 W Strawberry Ln #2 - 1011186506/26/2024 PROJECT:CASTILLO ENGINEERING 324 E South St, Long Beach, CA 90805 37683.00 Wood :Douglas-Fir/Larch Cr = 1.15 (repetitive member factor)Fv =180 psi (for Light Framing and Joists & Planks) E = 1,500,000 psi (Const Light Framing)Fv =170 psi (for Beams & Stringers and Posts & Timbers) E = 1,600,000 psi (#2 Joists & Planks, #1 Beams & Stringers, #1 Posts & Timbers) FLOO ROOF MEMBER:SIZE:(35 PCF)PROPERTIES:BENDING STRESS:1.00 (k-ft & k)Cd =1.00 (k-ft & k)Cd =1.25 Nominal Grade Type B (in)D (in)PLF (in^2)S(in^3)I(in^4)Fb(psi)CF Fb x CF max Mmax Mmax(rep)max Mmax Mmax(rep) 2x4 Const. LF 1.5 3.50 1.3 5.3 3.1 5.4 1000 1.00 1000 0.63 0.26 0.29 0.79 0.32 0.37 2x6 #2 JP 1.5 5.50 2.0 8.3 7.6 20.8 900 1.30 1170 0.99 0.74 0.85 1.24 0.92 1.06 2x8 #2 JP 1.5 7.25 2.6 10.9 13.1 47.6 900 1.20 1080 1.31 1.18 1.36 1.63 1.48 1.70 2x10 #2 JP 1.5 9.25 3.4 13.9 21.4 98.9 900 1.10 990 1.67 1.76 2.03 2.08 2.21 2.54 2x12 #2 JP 1.5 11.25 4.1 16.9 31.6 178.0 900 1.00 900 2.03 2.37 2.73 2.53 2.97 3.41 2x14 #2 JP 1.5 13.25 4.8 19.9 43.9 290.8 900 0.90 810 2.39 2.96 3.41 2.98 3.70 4.26 4x4 Const LF 3.5 3.50 3.0 12.3 7.1 12.5 1000 1.00 1000 1.47 0.60 0.68 1.84 0.74 0.86 4x6 #2 JP 3.5 5.50 4.7 19.3 17.6 48.5 900 1.30 1170 2.31 1.72 1.98 2.89 2.15 2.47 4x8 #2 JP 3.5 7.25 6.2 25.4 30.7 111.1 900 1.30 1170 3.05 2.99 3.44 3.81 3.74 4.30 4x10 #2 JP 3.5 9.25 7.9 32.4 49.9 230.8 900 1.20 1080 3.89 4.49 5.17 4.86 5.62 6.46 4x12 #2 JP 3.5 11.25 9.6 39.4 73.8 415.3 900 1.10 990 4.73 6.09 7.00 5.91 7.61 8.76 4x14 #2 JP 3.5 13.25 11.3 46.4 102.4 678.5 900 1.00 900 5.57 7.68 8.83 6.96 9.60 11.0 6x4 #2 JP 5.5 3.50 4.7 19.3 11.2 19.7 900 1.00 900 2.31 0.84 2.89 1.05 6x6 #1 PT 5.5 5.50 7.4 30.3 27.7 76.3 1200 1.00 1200 3.43 2.77 4.29 3.47 6x8 #1 PT 5.5 7.50 10.0 41.3 51.6 193.4 1200 1.00 1200 4.68 5.16 5.84 6.45 6x10 #1 BS 5.5 9.50 12.7 52.3 82.7 393.0 1350 1.00 1350 5.92 9.31 7.40 11.6 6x12 #1 BS 5.5 11.50 15.4 63.3 121.2 697.1 1350 1.00 1350 7.17 13.6 8.96 17.0 6x14 #1 BS 5.5 13.50 18.0 74.3 167.1 1127.7 1350 0.99 1332 8.42 18.6 10.5 23.2 2605 W Strawberry Ln #2 - 1011186506/26/2024 2605 W Strawberry Ln #2 - 1011186506/26/2024 2605 W Strawberry Ln #2 - 1011186506/26/2024 2605 W Strawberry Ln #2 - 1011186506/26/2024 2605 W Strawberry Ln #2 - 1011186506/26/2024 A-DESIGN LOADS-comp. shingles CASTILLO ENGINEERING, INC 324 E South St, Long Beach, CA 90805 ROOF LOADS composite shingles 2.5 psf re-roof 2.0 psf 1/2" plywwod 1.5 psf rafters 4.0 psf insulation 0.5 psf Ceiling 3.0 psf beams/headers 1.0 psf MP&E/ misc.0.5 psf D=15.0 psf Lr=20.0 psf REDUCIBLE FLOOR LOADS flooring 1.0 psf 3/4" plywood 2.3 psf joist 3.0 psf ceiling 4.0 psf beams/headers 2.0 psf MP&E/ misc.2.7 psf D=15.0 psf L=40.0 psf EXTERIOR WALL LOADS 7/8" stucco 10.0 psf 1/2" plywood 1.5 psf 2x6 studs at 16"oc 1.5 psf insulation 0.5 psf 1/2" gyp board 2.3 psf MP&E/ misc.0.2 psf D=16.0 psf INTERIOR WALL LOADS 1/2" gyp board 2.3 psf 1/2" plywood 1.5 psf 2x6 studs at 16"oc 1.5 psf insulation 0.5 psf 1/2" gyp board 2.3 psf MP&E/ misc.1.9 psf D=10.0 psf 2605 W Strawberry Ln #2 - 1011186506/26/2024 2605 W Strawberry Ln #2 - 1011186506/26/2024 2605 W Strawberry Ln #2 - 1011186506/26/2024 ARCHITECT JOB 1205 Pine Avenue, Suite 201 Long Beach, CA 90813 ENGR. MC DATE:JOB NO. SHEET NO. CASTILLO ENGINEERING, INC. REMARKS 4x4 4x4 4X4 4X6 4X67.15 10.83 ALLOWABLE 75% 2.31 3.42 4.23 6X6HDU14 3.075 4.565 5.645 6.970 9.535 14.445 5.23 HDU5 HDU8 HDU11 HOLDOWNS HDU2 HDU4 HD ALLOWABLE UPLIFT 2605 W Strawberry Ln #2 - 1011186506/26/2024 2605 W Strawberry Ln #2 - 1011186506/26/2024 CE Engineering Software v1.0 PROJECT: == TYPICAL SQUARE PAD FOOTING DESIGN TABLE == (2/99) Bar #Area (in2) Soil Bearing Pressure:Miscellaneous:3 0.11 q =1500 psf column footprint =4 in 4 0.20 qu = q x 1.6 =2400 psf steel spacing factor =10 5 0.31 (for selection of steel spacing vs. size only)6 0.44 Material Strengths:7 0.60 concrete =2500 psi Notes:8 0.78 fy =60 ksi Assumes Pu = 1.6 (DL + LL)9 1.00 10 1.23 11 1.56 Mark:Size Thick Pmax Depth Mu a As As As min As (ft) -SQ. (in) (k) (in)Vact (k) Vall (k)OK?Vact (k) Vall (k)OK? (k-in) (in) (Req'd)(200/Fy)(.0018) Use USE: 1.5 12 3.04 8 0.0 12.2 Y 2.7 65.3 Y 7 0.02 0.02 0.72 0.39 0.39 2 # 4 2.0 12 5.40 8 0.7 16.3 Y 6.5 65.3 Y 18 0.05 0.04 0.96 0.52 0.52 3 # 4 2.5 12 8.44 8 2.3 20.4 Y 11.3 65.3 Y 38 0.08 0.09 1.20 0.65 0.65 4 # 4 3.0 12 12.2 8 4.3 24.5 Y 17.3 65.3 Y 69 0.13 0.16 1.44 0.78 0.78 4 # 4 3.5 12 16.5 8 6.9 28.6 Y 24.3 65.3 Y 114 0.18 0.27 1.68 0.91 0.91 5 # 4 4.0 12 21.6 8 10.1 32.6 Y 32.4 65.3 Y 174 0.24 0.41 1.92 1.04 1.04 6 # 4 4.5 12 27.3 8 13.8 36.7 Y 41.6 65.3 Y 253 0.31 0.60 2.16 1.17 1.17 4 # 5 5.0 12 33.8 8 18.0 40.8 Y 51.8 65.3 Y 353 0.39 0.84 2.40 1.30 1.30 5 # 5 5.5 12 40.8 8 22.8 44.9 Y 63.2 65.3 Y 476 0.49 1.14 2.64 1.43 1.51 5 # 5 6.0 15 47.3 11 24.2 67.3 Y 72.3 112.2 Y 607 0.41 1.04 3.60 1.94 1.94 7 # 5 ONE WAY SHEAR:TWO WAY SHEAR: 2605 W Strawberry Ln #2 - 1011186506/26/2024 ROOF FRAMING KEY PLAN H1 H2 H2 H4 H4 H3 CJ1 2605 W Strawberry Ln #2 - 1011186506/26/2024 CASTILLO ENGINEERING INC.Project 1327 Loma Avenue Long Beach, CA 90804 Engr. Date:Job No.23-10263 Sheet Tag Beam 5 L = 20.5 ft Member= 2x10 A = 13.88 in^2 S = 21.4 in^3 No. of members= 1 I = 98.9 in^4 CD= 1.25 E = 1,600,000 psi CF= 1.10 Va = 1.665 kips CV= 1.00 Ma = 1.604 k-ft Cr= 1.00 Total Load L/n= 180 Live Load L/n= 240 L= 20.5ft 0.34 0.34 Uniform load (W1) D L Trib w1,1 (5 + 20) x 1.33 = 6.65 + 26.6 w1,2 (16 + ) x 0 = 0 + 0 w1,3 ( + ) x 0 = 0 + 0 w1,4 ( + ) x 0 = 0 + 0 w1,5 ( + ) x 0 = 0 + 0 W1 = 6.65 + 26.6 =0.033 kl Triangular load (W2) D L Trib ` w2,1 (0 + 0) x 0 = 0 + 0 w2,2 (0 + 0) x 0 = 0 + 0 w2,3 (0 + 0) x 0 = 0 + 0 w2,4 (0 + 0) x 0 = 0 + 0 w2,5 (0 + 0) x 0 = 0 + 0 W2 = 0 + 0 =0.000 kl Point Load (P1) D L Trib.1 Trib.2 p1,1 ( + ) x 0 x 0 = 0 + 0 p1,2 ( + ) x 0 x 0 = 0 + 0 p1,3 ( + ) x 0 x 0 = 0 + 0 p1,4 ( + ) x 0 x 0 = 0 + 0 p1,5 ( + ) x 0 x 0 = 0 + 0 X1 (ft) X2 (ft) P1 = 0 + 0 =0.00 kips 0 20.5 Point Load (P2) D L Trib.1 Trib.2 p2,1 ( + ) x 0 x 0 = 0 + 0 p2,2 ( + ) x 0 x 0 = 0 + 0 p2,4 ( + ) x 0 x 0 = 0 + 0 p2,4 ( + ) x 0 x 0 = 0 + 0 p2,5 ( + ) x 0 x 0 = 0 + 0 X3 (ft) X4 (ft) P2 = 0 + 0 =0.00 kips 0 20.5 Shear R1= 0.341 kips R2= -0.341 kips Stress Ratio Vmax= 0.34 kips allow.2.08 x 1 = 2.0813 kips OK .16 Flexure M= 1.75 k-ft Mallow.2.21 x 1 = 2.2059 k-ft OK .79 Deflection D =D w1 + Dw2 + D p1 + Dp2 D (D+L)= 0.835 + 0.000 + 0.000 + 0.000 = 0.83 = L < L OK deflection:.61 295 180 0.835 + 0 D (L Only)= 0.668 + 0 + 0 + 0 = 0.668 = L L OK deflection:.65 368 240 USE:1- 2X10 CJ1 flexure: shear: 2/23/24 12:00 AM 2605 W Strawberry Ln #2 - 1011186506/26/2024 CASTILLO ENGINEERING INC.Project 1327 Loma Avenue Long Beach, CA 90804 Engr. Date:Job No.23-10263 Sheet Tag Beam 5 L = 3 ft Member= 4x6 A = 19.25 in^2 S = 17.6 in^3 No. of members= 1 I = 48.5 in^4 CD= 1.25 E = 1,600,000 psi CF= 1.30 Va = 2.310 kips CV= 1.00 Ma = 1.323 k-ft Cr= 1.00 Total Load L/n= 180 Live Load L/n= 240 L= 3ft 0.28 0.28 Uniform load (W1) D L Trib w1,1 (15 + 20) x 3 = 45 + 60 w1,2 (16 + ) x 5 = 80 + 0 w1,3 ( + ) x 0 = 0 + 0 w1,4 ( + ) x 0 = 0 + 0 w1,5 ( + ) x 0 = 0 + 0 W1 = 125 + 60 =0.185 kl Triangular load (W2) D L Trib ` w2,1 (0 + 0) x 0 = 0 + 0 w2,2 (0 + 0) x 0 = 0 + 0 w2,3 (0 + 0) x 0 = 0 + 0 w2,4 (0 + 0) x 0 = 0 + 0 w2,5 (0 + 0) x 0 = 0 + 0 W2 = 0 + 0 =0.000 kl Point Load (P1) D L Trib.1 Trib.2 p1,1 ( + ) x 0 x 0 = 0 + 0 p1,2 ( + ) x 0 x 0 = 0 + 0 p1,3 ( + ) x 0 x 0 = 0 + 0 p1,4 ( + ) x 0 x 0 = 0 + 0 p1,5 ( + ) x 0 x 0 = 0 + 0 X1 (ft) X2 (ft) P1 = 0 + 0 =0.00 kips 0 3 Point Load (P2) D L Trib.1 Trib.2 p2,1 ( + ) x 0 x 0 = 0 + 0 p2,2 ( + ) x 0 x 0 = 0 + 0 p2,4 ( + ) x 0 x 0 = 0 + 0 p2,4 ( + ) x 0 x 0 = 0 + 0 p2,5 ( + ) x 0 x 0 = 0 + 0 X3 (ft) X4 (ft) P2 = 0 + 0 =0.00 kips 0 3 Shear R1= 0.278 kips R2= -0.278 kips Stress Ratio Vmax= 0.28 kips allow.2.89 x 1 = 2.8875 kips OK .10 Flexure M= 0.21 k-ft Mallow.2.15 x 1 = 2.1506 k-ft OK .10 Deflection D =D w1 + Dw2 + D p1 + Dp2 D (D+L)= 0.004 + 0.000 + 0.000 + 0.000 = 0.00 = L < L OK deflection:.02 8290 180 0.004 + 0 D (L Only)= 0.001 + 0 + 0 + 0 = 0.001 = L L OK deflection:.01 25561 240 USE:1- 4X6 H1 flexure: shear: 2/23/24 12:00 AM 2605 W Strawberry Ln #2 - 1011186506/26/2024 CASTILLO ENGINEERING INC.Project 1327 Loma Avenue Long Beach, CA 90804 Engr. Date:Job No.23-10263 Sheet Tag Beam 5 L = 3 ft Member= 4x6 A = 19.25 in^2 S = 17.6 in^3 No. of members= 1 I = 48.5 in^4 CD= 1.25 E = 1,600,000 psi CF= 1.30 Va = 2.310 kips CV= 1.00 Ma = 1.323 k-ft Cr= 1.00 Total Load L/n= 180 Live Load L/n= 240 L= 3ft 0.68 0.68 Uniform load (W1) D L Trib w1,1 (15 + 20) x 11.67 = 175.05 + 233.4 w1,2 (16 + ) x 3 = 48 + 0 w1,3 ( + ) x 0 = 0 + 0 w1,4 ( + ) x 0 = 0 + 0 w1,5 ( + ) x 0 = 0 + 0 W1 = 223.05 + 233.4 =0.456 kl Triangular load (W2) D L Trib ` w2,1 (0 + 0) x 0 = 0 + 0 w2,2 (0 + 0) x 0 = 0 + 0 w2,3 (0 + 0) x 0 = 0 + 0 w2,4 (0 + 0) x 0 = 0 + 0 w2,5 (0 + 0) x 0 = 0 + 0 W2 = 0 + 0 =0.000 kl Point Load (P1) D L Trib.1 Trib.2 p1,1 ( + ) x 0 x 0 = 0 + 0 p1,2 ( + ) x 0 x 0 = 0 + 0 p1,3 ( + ) x 0 x 0 = 0 + 0 p1,4 ( + ) x 0 x 0 = 0 + 0 p1,5 ( + ) x 0 x 0 = 0 + 0 X1 (ft) X2 (ft) P1 = 0 + 0 =0.00 kips 0 3 Point Load (P2) D L Trib.1 Trib.2 p2,1 ( + ) x 0 x 0 = 0 + 0 p2,2 ( + ) x 0 x 0 = 0 + 0 p2,4 ( + ) x 0 x 0 = 0 + 0 p2,4 ( + ) x 0 x 0 = 0 + 0 p2,5 ( + ) x 0 x 0 = 0 + 0 X3 (ft) X4 (ft) P2 = 0 + 0 =0.00 kips 0 3 Shear R1= 0.685 kips R2= -0.685 kips Stress Ratio Vmax= 0.68 kips allow.2.89 x 1 = 2.8875 kips OK .24 Flexure M= 0.51 k-ft Mallow.2.15 x 1 = 2.1506 k-ft OK .24 Deflection D =D w1 + Dw2 + D p1 + Dp2 D (D+L)= 0.011 + 0.000 + 0.000 + 0.000 = 0.01 = L < L OK deflection:.05 3360 180 0.011 + 0 D (L Only)= 0.005 + 0 + 0 + 0 = 0.005 = L L OK deflection:.04 6571 240 USE:1- 4X6 H2 flexure: shear: 2/23/24 12:00 AM 2605 W Strawberry Ln #2 - 1011186506/26/2024 CASTILLO ENGINEERING INC.Project 1327 Loma Avenue Long Beach, CA 90804 Engr. Date:Job No.23-10263 Sheet Tag Beam 5 L = 5 ft Member= 4x6 A = 19.25 in^2 S = 17.6 in^3 No. of members= 1 I = 48.5 in^4 CD= 1.25 E = 1,600,000 psi CF= 1.30 Va = 2.310 kips CV= 1.00 Ma = 1.323 k-ft Cr= 1.00 Total Load L/n= 180 Live Load L/n= 240 L= 5ft 0.46 0.46 Uniform load (W1) D L Trib w1,1 (15 + 20) x 3 = 45 + 60 w1,2 (16 + ) x 5 = 80 + 0 w1,3 ( + ) x 0 = 0 + 0 w1,4 ( + ) x 0 = 0 + 0 w1,5 ( + ) x 0 = 0 + 0 W1 = 125 + 60 =0.185 kl Triangular load (W2) D L Trib ` w2,1 (0 + 0) x 0 = 0 + 0 w2,2 (0 + 0) x 0 = 0 + 0 w2,3 (0 + 0) x 0 = 0 + 0 w2,4 (0 + 0) x 0 = 0 + 0 w2,5 (0 + 0) x 0 = 0 + 0 W2 = 0 + 0 =0.000 kl Point Load (P1) D L Trib.1 Trib.2 p1,1 ( + ) x 0 x 0 = 0 + 0 p1,2 ( + ) x 0 x 0 = 0 + 0 p1,3 ( + ) x 0 x 0 = 0 + 0 p1,4 ( + ) x 0 x 0 = 0 + 0 p1,5 ( + ) x 0 x 0 = 0 + 0 X1 (ft) X2 (ft) P1 = 0 + 0 =0.00 kips 0 5 Point Load (P2) D L Trib.1 Trib.2 p2,1 ( + ) x 0 x 0 = 0 + 0 p2,2 ( + ) x 0 x 0 = 0 + 0 p2,4 ( + ) x 0 x 0 = 0 + 0 p2,4 ( + ) x 0 x 0 = 0 + 0 p2,5 ( + ) x 0 x 0 = 0 + 0 X3 (ft) X4 (ft) P2 = 0 + 0 =0.00 kips 0 5 Shear R1= 0.463 kips R2= -0.463 kips Stress Ratio Vmax= 0.46 kips allow.2.89 x 1 = 2.8875 kips OK .16 Flexure M= 0.58 k-ft Mallow.2.15 x 1 = 2.1506 k-ft OK .27 Deflection D =D w1 + Dw2 + D p1 + Dp2 D (D+L)= 0.034 + 0.000 + 0.000 + 0.000 = 0.03 = L < L OK deflection:.10 1791 180 0.034 + 0 D (L Only)= 0.011 + 0 + 0 + 0 = 0.011 = L L OK deflection:.04 5521 240 USE:1- 4X6 H3 flexure: shear: 2/23/24 12:00 AM 2605 W Strawberry Ln #2 - 1011186506/26/2024 CASTILLO ENGINEERING INC.Project 1327 Loma Avenue Long Beach, CA 90804 Engr. Date:Job No.23-10263 Sheet Tag Beam 5 L = 1.17 ft Member= 4x6 A = 19.25 in^2 S = 17.6 in^3 No. of members= 1 I = 48.5 in^4 CD= 1.25 E = 1,600,000 psi CF= 1.30 Va = 2.310 kips CV= 1.00 Ma = 1.323 k-ft Cr= 1.00 Total Load L/n= 180 Live Load L/n= 240 L= 1.17ft 0.27 0.27 Uniform load (W1) D L Trib w1,1 (15 + 20) x 11.67 = 175.05 + 233.4 w1,2 (16 + ) x 3 = 48 + 0 w1,3 ( + ) x 0 = 0 + 0 w1,4 ( + ) x 0 = 0 + 0 w1,5 ( + ) x 0 = 0 + 0 W1 = 223.05 + 233.4 =0.456 kl Triangular load (W2) D L Trib ` w2,1 (0 + 0) x 0 = 0 + 0 w2,2 (0 + 0) x 0 = 0 + 0 w2,3 (0 + 0) x 0 = 0 + 0 w2,4 (0 + 0) x 0 = 0 + 0 w2,5 (0 + 0) x 0 = 0 + 0 W2 = 0 + 0 =0.000 kl Point Load (P1) D L Trib.1 Trib.2 p1,1 ( + ) x 0 x 0 = 0 + 0 p1,2 ( + ) x 0 x 0 = 0 + 0 p1,3 ( + ) x 0 x 0 = 0 + 0 p1,4 ( + ) x 0 x 0 = 0 + 0 p1,5 ( + ) x 0 x 0 = 0 + 0 X1 (ft) X2 (ft) P1 = 0 + 0 =0.00 kips 0 1.17 Point Load (P2) D L Trib.1 Trib.2 p2,1 ( + ) x 0 x 0 = 0 + 0 p2,2 ( + ) x 0 x 0 = 0 + 0 p2,4 ( + ) x 0 x 0 = 0 + 0 p2,4 ( + ) x 0 x 0 = 0 + 0 p2,5 ( + ) x 0 x 0 = 0 + 0 X3 (ft) X4 (ft) P2 = 0 + 0 =0.00 kips 0 1.17 Shear R1= 0.267 kips R2= -0.267 kips Stress Ratio Vmax= 0.27 kips allow.2.89 x 1 = 2.8875 kips OK .09 Flexure M= 0.08 k-ft Mallow.2.15 x 1 = 2.1506 k-ft OK .04 Deflection D =D w1 + Dw2 + D p1 + Dp2 D (D+L)= 0.000 + 0.000 + 0.000 + 0.000 = 0.00 = L < L OK deflection:.00 56643 180 2E-04 + 0 D (L Only)= 1E-04 + 0 + 0 + 0 = 1E-04 = L L OK deflection:.00 110773 240 USE:1- 4X6 H2 flexure: shear: 2/23/24 12:00 AM 2605 W Strawberry Ln #2 - 1011186506/26/2024 CF 1 FOUNDATION KEY PLAN 2605 W Strawberry Ln #2 - 1011186506/26/2024 ARCHITECT CASTILLO ENGINEERING, INC.JOB 1205 Pine Avenue, Suite 201, Long Beach, CA 90813 ENGR. MC DATE JOB NO. 23-10263 SHEET NO. CONTINUOUS FOOTINGS CF-1 LOADING: TRIB. ( + ) x ft = + ( + ) x ft = + ( + ) x ft = + w = + = plf B= plf = ft psf USE: 580 16 340 4015 0 WALL: 10 09/05/2024 20 D L ROOF: FLOOR: 15 12 1500 580 160 240 0 0 180 0 240 0 0.39 1'-0" WIDE FTG. F-CONTINUOUS FOOTINGS-1500 2605 W Strawberry Ln #2 - 1011186506/26/2024 ASCE Hazards Report Address: 2605 Strawberry Ln Santa Ana, California 92706 Standard:ASCE/SEI 7-22 Latitude:33.762334 Risk Category:II Longitude:-117.904498 Soil Class:Default Elevation:98.40174611801588 ft (NAVD 88) Page 1 of 4https://ascehazardtool.org/Fri Feb 23 2024 2605 W Strawberry Ln #2 - 1011186506/26/2024 PGA M : 0.68 SMS : 1.77 SM1 : 1.26 SDS : 1.18 SD1 : 0.84 T L : 8 SS : 1.52 S1 : 0.58 VS30 : 260 Seismic Design Category:D Multi-Period Design Spectrum S (g) vs T(s)a Multi-Period MCE SpectrumR S (g) vs T(s)a Two-Period Design Spectrum S (g) vs T(s)a Two-Period MCE SpectrumR S (g) vs T(s)a Design Vertical Response Spectrum Vertical ground motion data has not yet been made available by USGS. MCE Vertical Response SpectrumR Vertical ground motion data has not yet been made available by USGS. Seismic DefaultSite Soil Class: Results: Page 2 of 4https://ascehazardtool.org/Fri Feb 23 2024 2605 W Strawberry Ln #2 - 1011186506/26/2024 Data Accessed: Fri Feb 23 2024 Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-22 and ASCE/SEI 7-22 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-22 Ch. 21 are available from USGS. Page 3 of 4https://ascehazardtool.org/Fri Feb 23 2024 2605 W Strawberry Ln #2 - 1011186506/26/2024 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 4 of 4https://ascehazardtool.org/Fri Feb 23 2024 2605 W Strawberry Ln #2 - 1011186506/26/2024 AREA AND WALLS PERIMETER A=755.33 SQ. FT. P=103.25 FT. 2605 W Strawberry Ln #2 - 1011186506/26/2024 Castillo Engineering Inc.JOB: 1205 Pine Avenue, Suite 201 Long Beach, CA 90813 ENGR:JOB NO. SHEET NO. SEISMIC BASE SHEAR (ASCE 7-22) Degrees Degrees (Table 20.3-1) R = (Table 12.2-1) SMS = S1 = SM1 = SDS = (2/3)SMS (11.4-3) = (2/3)x = SD1 = (2/3)SM1 (11.4-4) = (2/3)x = Ta =Ct hn x (12.8-7) =x 12 = V = Cs W VMIN = W VMIN = 0.5 S1 Ie W For S1 is equal to or greater than 0.6g = x x W = W [GOVERNS] VMAX = W =x W = W x V =W =x x W = x W = W [Strength Level] V = x W = W [Allowable Stress Design] 0 23-10263 D 6.5 FG DATE: 23/02/2024 Latitude: 0.129 1.77 1.26 0.840 0.02 0.75 1.77 0.58 Longitude: 33.762334 -117.9045 SITE CLASS: 1.26 1.180 1.00219 SDS Ie 0.840 1.00 0.129 6.5 SD1 Ie 6.5 T R 0.01 R 0.5 0.5800 1.00 6.5 0.045 0.7 0.17 0.237 1.30.182 0.237 R 1.180 1.00 1.3 2605 W Strawberry Ln #2 - 1011186506/26/2024 Castillo Engineering Inc.JOB 1205 Pine Avenue, Suite 201 FG DATE JOB NO. 23-10263 SHEET NO. SEISMIC ANALYSIS WEIGHT Wroof = ( 15 s + 5.0 s ) x ft^2 = kips Wwall = 16 s x 8 ft /2 x ft = kips W2 = kips BASE SHEAR = x = x = kips WTOTAL 0 21.7 15.1 103.25 6.6 755.33 lbs/sq ft 23/02/2024 VBASE ENGR. VBASE 0.17 3.600.17 21.7 (4.772) 2605 W Strawberry Ln #2 - 1011186506/26/2024 X1.1 X2.1 A=377.66 A=377.66 SHEAR KEY KEY PLAN X 2605 W Strawberry Ln #2 - 1011186506/26/2024 Y1.1 Y1.2 Y2.1 A=377.66 A=377.66 SHEAR KEY KEY PLAN Y 2605 W Strawberry Ln #2 - 1011186506/26/2024 ARCHITECT JOB 0.00 ENGR. MC DATE:JOB NO. 23-10263 SHEET NO. F1= 4.772 SW U-FORCE T.A. FORCE L1 L2 L3 L4 HEIGHT X1 4.77 377.66 1.80 8.33 8.00 X2 4.77 377.66 1.80 13.50 8.00 Y1 4.77 377.66 1.80 13.50 13.67 8.00 Y2 4.77 377.66 1.80 11.67 8.00 SEISMIC FORCES FLOOR 1 Castillo Engineering, Inc. February 23, 2024 SEISMIC DESIGN FORCES 1205 PINE AVE LONG BEACH CA 2605 W Strawberry Ln #2 - 1011186506/26/2024 ARCHITECT JOB CASTILLO ENGINEERING, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 JOB NO. 23-10263 SHEET NO. TAG:X1.1 ( 8.33 ft),X1.2 ( 0.00 ft) FORCE: ###kips 0.00 0.00 ft F1=kips H1:8.00 ft SEISMIC GOVERNS FTOTAL=kips Load Comb.:(0.6-.14SDS) D + 0.7 E SDS= 1.18 SHEAR STRESS X1.1 :L1= ft v= lbs = plf X1.2 :L2= ft ft Ltotal= ft OVERTURNING MOT= x 8.33 x 8.0 = k-ft 8.33 ROOF: psf x ft = plf FLOOR: psf x ft = plf h/w=0.78 OK WALL: psf x ft = plf w = plf Vallow=340 PLF MR= x 8.33 ^2/2 = k-ft USE: TYPE 6 SHEARWALL - 0.43 x = kips kips OK USE:4 x 4 POST w/ H.D. 2-H.D.11 Tallow= 2X9.34 = 18.68 MIN. HDU2 HDU2 1.44 0 0.00 0 8.33 Tallow=3.08 0.158 5.48 T= 14.4 16 8.00 128 158 5.48 WALL:X1.1 1.80 15 2.00 Unit load 30 14.42 Tributary 8.33 0.00 8.33 SHEARWALL CALCULATIONS-LEVEL 1 0.00 1.80 1.80 8.33 1802 216 2605 W Strawberry Ln #2 - 1011186506/26/2024 ARCHITECT JOB CASTILLO ENGINEERING, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 JOB NO. 23-10263 SHEET NO. TAG:X2.1 ( 13.50 ft),X2.2 ( 0.00 ft) FORCE: ###kips 0.00 0.00 ft F1=kips H1:8.00 ft SEISMIC GOVERNS FTOTAL=kips Load Comb.:(0.6-.14SDS) D + 0.7 E SDS= 1.18 SHEAR STRESS X2.1 :L1= ft v= lbs = plf X2.2 :L2= ft ft Ltotal= ft OVERTURNING MOT= x 13.50 x 8.0 = k-ft 13.50 ROOF: psf x ft = plf FLOOR: psf x ft = plf h/w=0.48 OK WALL: psf x ft = plf w = plf Vallow=340 PLF MR= x 13.50 ^2/2 = k-ft USE: TYPE 6 SHEARWALL - 0.43 x = kips kips OK USE:4 x 4 POST w/ H.D. 2-H.D.11 Tallow= 2X9.34 = 18.68 MIN. HDU2 HDU2 0.60 0 0.00 0 13.50 Tallow=3.08 0.158 14.40 T= 14.4 16 8.00 128 158 14.40 WALL:X2.1 1.80 15 2.00 Unit load 30 14.42 Tributary 13.50 0.00 13.50 SHEARWALL CALCULATIONS-LEVEL 1 0.00 1.80 1.80 13.50 1802 133 2605 W Strawberry Ln #2 - 1011186506/26/2024 ARCHITECT JOB CASTILLO ENGINEERING, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 JOB NO. 23-10263 SHEET NO. TAG:Y1.1 ( 13.50 ft),Y1.2 ( 13.67 ft) FORCE: ###kips 0.00 0.00 ft F1=kips H1:8.00 ft SEISMIC GOVERNS FTOTAL=kips Load Comb.:(0.6-.14SDS) D + 0.7 E SDS= 1.18 SHEAR STRESS Y1.1 :L1= ft v= lbs = plf Y1.2 :L2= ft ft Ltotal= ft OVERTURNING MOT= x 13.50 x 8.0 = k-ft 27.17 ROOF: psf x ft = plf FLOOR: psf x ft = plf h/w=0.48 OK WALL: psf x ft = plf w = plf Vallow=340 PLF MR= x 13.50 ^2/2 = k-ft USE: TYPE 6 SHEARWALL - 0.43 x = kips kips OK USE:4 x 4 POST w/ H.D. 2-H.D.11 Tallow= 2X9.34 = 18.68 MIN. HDU2 MOT= x 13.67 x 8.0 = k-ft 27.17 ROOF: psf x ft = plf FLOOR: psf x ft = plf h/w=0.48 OK WALL: psf x ft = plf w = plf Vallow=340 PLF MR= x 13.67 ^2/2 = k-ft USE: TYPE 6 SHEARWALL - 0.43 x = kips kips OK USE:4 x 4 POST w/ H.D. MIN. HDU2 HDU2 0.06 NO 0.00 7.25 13.67 Tallow=3.08 0.158 14.76 T= 7.3 14.76 16 8 128 158 Tributary 15 2 30 0 0 0 WALL:Y1.2 1.80 Unit load 0 0.00 0 13.50 Tallow=3.08 0.303 27.62 T= 7.2 16 8.00 128 303 27.62 WALL:Y1.1 1.80 15 11.67 Unit load 175 7.16 Tributary 27.17 13.67 27.17 SHEARWALL CALCULATIONS-LEVEL 1 0.00 1.80 1.80 13.50 1802 66 2605 W Strawberry Ln #2 - 1011186506/26/2024 ARCHITECT JOB CASTILLO ENGINEERING, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 JOB NO. 23-10263 SHEET NO. TAG:Y2.1 (11.67 ft),Y2.2 ( 0.00 ft) FORCE: ###kips 0.00 0.00 ft F1=kips H1:8.00 ft SEISMIC GOVERNS FTOTAL=kips Load Comb.:(0.6-.14SDS) D + 0.7 E SDS= 1.18 SHEAR STRESS Y2.1 :L1= ft v= lbs = plf Y2.2 :L2= ft ft Ltotal= ft OVERTURNING MOT=x 10.17 x 8.0 =k-ft 10.17 ROOF:psf x ft =plf FLOOR:psf x ft =plf h/w=0.64 OK WALL:psf x ft =plf w =plf Vallow=340 PLF MR=x 10.17 ^2/2 =k-ft USE: TYPE 6 SHEARWALL - 0.43 x =kips kips OK USE:4 x 4 POST w/H.D. 2-H.D.11 Tallow= 2X9.34 = 18.68 MIN. HDU2 HDU2 0.75 0 0.00 0 10.17 Tallow=3.08 0.303 15.67 T= 14.4 16 8.00 128 303 15.67 WALL:Y2.1 1.80 15 11.67 Unit load 175 14.42 Tributary 10.17 0.00 10.17 SHEARWALL CALCULATIONS-LEVEL 1 0.00 1.80 1.80 10.17 1802 177 2605 W Strawberry Ln #2 - 1011186506/26/2024 APP-13 CBC 2016 NOTICE TO PROPERTY OWNER Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvem ents specified at ___________________________________________________________________________________________. We are providing you with an Owner-Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your names as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owne r, obtain the prior approval of the permitting authority. OWNER’S ACKNOWLEGMENT AND VERIFICATION OF INFORMATON DIRECTIONS: Read and initial each statement below to signify you understand or verify this information. _____1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an “Owner -Builder” build- ing permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner’s insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my prop- erty. _____2. I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. _____3. I understand as an “Owner-Builder” I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead o f my own. _____4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbe rs on permits and contracts. _____5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an “employer” under state and federal law. _____6. I understand if I am considered an “employer” under state and Federal law, I must register with the state and federa l government, withhold payroll taxes, provide workers’ compensation disability insurance, and contribute to unemployment com- pensation of each “employee.” I also understand my failure to abide by these laws may subject me to serious financial risk. _____7. I understand under California Contractors’ State License Law, an Owner -Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontrac- tors and the number of structures does not exceed four within any calendar years, or all of the work is performed under contr act with a licensed general building Contractor. _____8. I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any f inan- cial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workma n- ship or materials. Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 2605 W Strawberry Lane #2 DL DL DL DL DL DL DL DL 2605 W Strawberry Ln #2 - 1011186506/26/2024 _____9. I understand I may obtain more information regarding my obligations as an “employer” from the Internal Revenue Ser- vice, the United States Small Business Administration, the California Department of Benefit Payments, and the California Divi- sion of Industrial Accidents. I also understand I may contact the California Contractors’ State License Board (CSLB) at 1 -800- 321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. _____10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the following ad- dress:_________________________________________________________________________________________. _____11. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner Builders as well as employers. ____12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the informati on I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors’ State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to underst and that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner Builder and wish to hire Contactors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers’ compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner’s driver’s license, form notariza- tion, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner’s signature. Signature of Property Owner _____________________________________________ Date: ______________________ Print name of Owner __________________________________________________ AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER’S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner Builder Permit for my project. Scope of Construction Project (or Description of Work):_______________________________________________________ Project Location or Address: ____________________________________________________________________________ Name of Authorized Agent: _____________________________________________________________________________ Address of Authorized Agent:__________________________________________________________________________ Phone Number of Authorized Agent: ______________________________________________________________________ I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Property Owner’s Signature: __________________________________________________ Date:______________________ Print Name of Owner: ______________________________________________________________ Note: A copy of the owner’s driver’s license, form notarization, or other verification acceptable to the agency is re- quired to be presented when the permit is issued to verify the property owner’s signature. DL DL 2605 Strawberry Lane DL DL 3/7/2024 Duy Lai 2605 W Strawberry Lane #2 2605 W Strawberry Ln #2 - 1011186506/26/2024 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area to Total Resulting Stories: Area Added in Past 2 Years Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed (PR400-402) Fire Sprinkler   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR 2605 W Strawberry Ln #2 - 1011186506/26/2024