Loading...
HomeMy WebLinkAbout2621 S Birch St - 101119515 & 20182981 - PlanG NOTES TO SUBCONTRACTOR: 1. THE GENERAL SUBCONTRACTOR MUST VERIFY ALL DIMENSIONS, CONDITIONS AND ELEVATIONS BEFORE PROCEEDING WITH THE WORK. ALL DISCREPANCIES SHALL BE RESOLVED BEFORE PROCEEDING WITH THE WORK. ALL WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH ACCEPTED CONSTRUCTION PRACTICES. 2. IT IS THE INTENTION OF THESE DRAWINGS TO SHOW THE COMPLETED INSTALLATION. THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING, SHORING, TIES, FORM WORK, ETC. IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL ORDINANCES, TO SAFELY EXECUTE ALL WORK AND SHALL BE RESPONSIBLE FOR SAME. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES. 3. THE SUBCONTRACTOR SHALL USE ADEQUATE NUMBER OF SKILLED WORKMAN WHO ARE THOROUGHLY TRAINED AND EXPERIENCED IN THE NECESSARY CRAFTS AND WHO ARE COMPLETELY FAMILIAR WITH THE SPECIFIED REQUIREMENTS AND METHOD NEEDED FOR PROPER PERFORMANCE OF THE WORK. 4. SUBCONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION SUBCONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND SUBCONTRACTOR FURTHER AGREES TO INDEMNIFY AND HOLD DESIGN ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH PERFORMANCE OF WORK ON THIS PROJECT. 5. SITE GROUNDING SHALL COMPLY WITH AT&T WIRELESS SERVICES TECHNICAL SPECIFICATIONS FOR FACILITY GROUNDING FOR CELL SITE STANDARDS, LATEST EDITION, AND COMPLY WITH AT&T TOWERS GROUNDING CHECKLIST, LATEST VERSION. WHEN NATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT THEY SHALL GOVERN. 6. ALL WORK SHALL COMPLY WITH OSHA AND STATE SAFETY REQUIREMENTS. PROCEDURES FOR THE PROTECTION OF EXCAVATIONS, EXISTING CONSTRUCTION AND UTILITIES SHALL BE ESTABLISHED PRIOR TO FOUNDATION INSTALLATION. 7. ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL CODES OR ORDINANCES. THE MOST STRINGENT CODE WILL APPLY IN THE CASE OF DISCREPANCIES OR DIFFERENCES IN THE CODE REQUIREMENTS. 8. ANY DAMAGE TO THE ADJACENT PROPERTIES WILL BE CORRECTED AT THE SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE LANDOWNER AND THE CONSTRUCTION MANAGER. 9. THE COMPLETE BID PACKAGE INCLUDES THESE CONSTRUCTION DRAWINGS ALONG WITH THE SPECIFICATIONS. SUBCONTRACTOR IS RESPONSIBLE FOR REVIEW OF TOTAL BID PACKAGE PRIOR TO BID SUBMITTAL. 10. SUBCONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES WITHIN CONSTRUCTION LIMITS PRIOR TO CONSTRUCTION. 11. THE SUBCONTRACTOR IS RESPONSIBLE FOR MAINTAINING POSITIVE DRAINAGE ON THE SITE AT ALL TIMES. SILT AND EROSION CONTROL SHALL BE MAINTAINED ON THE DOWNSTREAM SIDE OF THE SITE AT ALL TIMES. ANY DAMAGE TO ADJACENT PROPERTIES WILL BE CORRECTED AT THE SUBCONTRACTOR'S EXPENSE. 12. CLEARING OF TREES AND VEGETATION ON THE SITE SHOULD BE HELD TO A MINIMUM. ONLY THE TREES NECESSARY FOR CONSTRUCTION OF THE FACILITIES SHALL BE REMOVED. ANY DAMAGE TO THE PROPERTY OUTSIDE THE LEASED PROPERTY SHALL BE REPAIRED BY THE SUBCONTRACTOR. 13. ALL SUITABLE BORROW MATERIAL FOR BACK FILL OF THE SITE SHALL BE INCLUDED IN THE BID. EXCESS TOPSOIL AND UNSUITABLE MATERIAL SHALL BE DISPOSED OF OFF SITE AT LOCATIONS APPROVED BY GOVERNING AGENCIES PRIOR TO DISPOSAL. 14. PERMITS: THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND INCURRING THE COST OF ALL REQUIRED PERMITS, INSPECTIONS, CERTIFICATES, ETC. 15. RECORD DRAWINGS: MAINTAIN A RECORD OF ALL CHANGES, SUBSTITUTIONS BETWEEN WORK AS SPECIFIED AND INSTALLED. RECORD CHANGES ON A CLEAN SET OF CONTRACT DRAWINGS WHICH SHALL BE TURNED OVER TO THE CONSTRUCTION MANAGER UPON COMPLETION OF THE PROJECT. 16. THE PLANS SHOW SOME KNOWN SUBSURFACE STRUCTURES, ABOVE GROUND STRUCTURES AND/OR EXISTING UTILITIES BELIEVED TO BE IN THE WORKING AREA. IT IS THE RESPONSIBILITY OF THE SUBCONTRACTOR TO VERIFY ALL UTILITIES, PIPELINES AND OTHER STRUCTURES SHOWN OR NOT SHOWN ON THESE PLANS. THE SUBCONTRACTOR SHALL CONTACT THE LOCAL LOCATE SERVICE BEFORE DIGGING OR DRILLING. ANY DAMAGE TO EXISTING UTILITIES SHALL BE REPAIRED TO THE SATISFACTION OF THE OWNER AND ENGINEER AT THE SUBCONTRACTOR'S EXPENSE. GENERAL PROJECT NOTES: 1. THIS PROPOSAL IS FOR THE ADDITION OF A NEW GENERATOR ON A NEW CONCRETE PAD TO AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY CONSISTING OF AN EQUIPMENT SHELTER/PLATFORM AND TOWER. 2. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE. 3. THE PROPOSED FACILITY IS UNMANNED AND IS NOT FOR HUMAN HABITAT. (NO HANDICAP ACCESS IS REQUIRED) 4. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES PER MONTH BY AT&T TECHNICIANS. 5. OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE NOT PROPOSED. 6. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 7. SUBCONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE CONSTRUCTION OPERATION. 8. SUBCONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTION REQUIRED FOR CONSTRUCTION. 9. SUBCONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. ELECTRICAL NOTES: A. GENERAL 1. COORDINATE LOCATION AND POWER REQUIREMENTS OF ALL EQUIPMENT WITH AT&T AND EQUIPMENT SUPPLIER PRIOR TO INSTALLATION. 2. COORDINATE LOCATION AND REQUIREMENTS FOR ELECTRICAL AND TELEPHONE SERVICES WITH THE PROPERTY REPRESENTATIVE, AT&T AND UTILITY COMPANIES. ROUTING OF CONDUITS MAY BE MODIFIED TO MEET SITE REQUIREMENTS. EXACT CONDUIT ROUTING TO BE DETERMINED IN THE FIELD. 3. ALL WIRING AND EQUIPMENT SHOWN ON ELECTRICAL SHEETS SHALL BE FURNISHED AND INSTALLED UNDER ELECTRICAL PORTION OF CONTRACT UNLESS OTHERWISE NOTED 4. UNINTERRUPTED ELECTRICAL SERVICE FOR EXISTING EQUIPMENT SHALL BE MAINTAINED DURING THE INSTALLATION OF THE WORK DESCRIBED UNDER THESE DOCUMENTS. TEMPORARY EQUIPMENT, CABLES AND WHATEVER ELSE IS NECESSARY SHALL BE PROVIDED AS REQUIRED TO MAINTAIN ELECTRICAL SERVICE. TEMPORARY SERVICE FACILITIES, IF REQUIRED AT ANY TIME, SHALL NOT BE DISCONNECTED OR REMOVED UNTIL NEW SERVICE EQUIPMENT IS IN PROPER OPERATION. IF ANY SERVICE OR SYSTEM MUST BE INTERRUPTED, THE CONTRACTOR SHALL REQUEST PERMISSION IN WRITING STATING THE DATE, TIME, ETC. THE SERVICE WILL BE INTERRUPTED AND THE AREAS AFFECTED. THIS REQUEST SHALL BE MADE IN SUFFICIENT TIME FOR PROPER ARRANGEMENTS TO BE MADE. WRITTEN PERMISSION SHALL BE OBTAINED FROM THE OWNER BEFORE INTERRUPTING ELECTRICAL SERVICE. 5. COORDINATE NEW WORK WITH OTHER TRADES AND VERIFY EXISTING CONDITIONS TO AVOID INTERFERENCE. IN CASE OF INTERFERENCE, AT&T'S REPRESENTATIVE WILL DECIDE WHICH WORK IS TO BE RELOCATED, REGARDLESS OF WHICH WAS FIRST INSTALLED. 6. THE INSTALLATION MUST COMPLY WITH NEC AND ALL FEDERAL, STATE AND LOCAL RULES AND REGULATIONS. 7. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND EQUIPMENT UNLESS OTHERWISE DEFINED BY DIMENSIONS OR DETAILS. EXACT EQUIPMENT LOCATIONS AND RACEWAY ROUTING SHALL BE GOVERNED BY ACTUAL FIELD CONDITIONS AND/OR DIRECTIONS FROM AT&T'S REPRESENTATIVE. 8. CONTRACTOR SHALL PAY ALL PERMITS AND FEES REQUIRED. 9. ALL MATERIALS SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE STANDARDS REFERENCED BELOW: a. ANSI (AMERICAN NATIONAL STANDARDS INSTITUTE) b. ASTIM (AMERICAN SOCIETY FOR TESTING MATERIALS) c. ETL (ELECTRICAL TESTING LABORATORY) d. ICEA (INSULATED CABLE ENGINEERS ASSOCIATION) e. IEEE (INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS) f. MBFU (NATIONAL BOARD OF FIRE UNDERWRITERS) g. NESC (NATIONAL ELECTRICAL SAFETY CODE) h. NEMA (NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION) i. NFPA (NATIONAL FIRE PROTECTION ASSOCIATION) j. UL (UNDERWRITER'S LABORATORY) k. NEC (NATIONAL ELECTRICAL CODE) 10. CONTRACTOR SHALL REVIEW PLANS, DETAILS AND SPECIFICATIONS IN DETAIL AND ADJUST WORK TO CONFORM WITH ACTUAL SITE CONDITIONS SO THAT ELECTRICAL DEVICES AND EQUIPMENT WILL BE LOCATED AND READILY ACCESSIBLE. QUANTITIES LISTED IN MATERIAL LISTS ON THE DRAWINGS ARE FOR INFORMATION ONLY. THE CONTRACTOR SHALL PROVIDE HIS OWN TAKEOFF FOR MATERIAL QUANTITY AND TYPES BASED ON ACTUAL SITE CONDITIONS, IN ADDITION, CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIALS TO INSTALL EQUIPMENT FURNISHED BY AT&T OR ITS SUPPLIERS. ALL ITEMS NOT SPECIFICALLY MENTIONED HEREIN OR SHOWN ON THE DRAWINGS, BUT WHICH ARE OBVIOUSLY NECESSARY TO MAKE A COMPLETE WORKING INSTALLATION, SHALL BE INCLUDED. 11. THE CONTRACTOR OR BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) AT&T'S REPRESENTATIVE OF ANY CONFLICTS PRIOR TO THE SUBMISSION OF CONTRACTOR'S PROPOSAL OR PERFORMANCE OF WORK, IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED IN WRITING OTHERWISE. ELECTRICAL NOTES: 12. ALL FLOORS WHERE PENETRATIONS ARE REQUIRED IN BUILDING ARE TO BE CORE DRILLED AND THEN FIREPROOFED. B. WIRING/CONDUIT 1. PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR AS REQUIRED BY CODE SUCH THAT NO MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL) EXIST IN A CONDUIT RUN. 2. ALL POWER AND CONTROL/INDICATION WIRING SHALL BE TYPE THHN/THWN 600V RATED 75 DEGREES CELSIUS, UNLESS NOTED OTHERWISE. 3. CONDUIT BENDS SHALL BE MADE IN ACCORDANCE WITH NEC TABLE 346-10. NO RIGHT ANGLE DEVICE OTHER THAN STANDARD CONDUIT ELBOWS WITH 12" MINIMUM INSIDE SWEEPS FOR ALL CONDUITS 2" OR LARGER. 4. POWER WIRING SIZE SHALL NOT BE SMALLER THAN #12 AWG. 5. ALL WIRING SHALL BE COPPER. ALUMINUM WILL NOT BE ACCEPTABLE ALL POWER CIRCUITS SHALL CONTAIN A GROUND WIRE. 6. PHASE MARKINGS TO BE USED AT POWER CONDUCTOR TERMINATIONS. 7. CONTRACTOR SHALL ENSURE INTEGRITY IS MAINTAINED WHEN INSTALLING CONDUIT AND WIRING. 8. INSTALL PULL STRING IN ALL CONDUIT. 9. FOR ROOFTOP INSTALLS AND BUILD-OUTS, CONDUITS INSIDE BUILDING AND ON ROOF SHALL BE RGS, UNLESS OTHERWISE NOTED. FOR RAW LAND SITES AND CO-LOCATES, PVC SCHEDULE 80 SHALL BE UTILIZED UNLESS NOTED OTHERWISE. 10. MAINTAIN MINIMUM 1'-0" VERTICAL AND 1'-0" HORIZONTAL SEPARATIONS FROM ANY MECHANICAL GAS PIPING. 11. ALL WIRING ROUTED IN PLENUM TO BE RATED OR IN METALLIC FLEX (LIQUIDTITE) CONDUIT. C. EQUIPMENT 1. EQUIPMENT/PARTS CONNECTED TO EXISTING PANELS, DUCTS, ETC. SHALL MATCH THE CHARACTERISTICS (A/C, V, A) OF THAT EQUIPMENT. 2. ALL ELECTRICAL EQUIPMENT OUTSIDE SHALL BE NEMA 3R RATED. D. GROUNDING 1. ALL GROUND CONNECTIONS TO BUILDING SHALL BE MADE USING TWO-HOLE CONNECTORS. PROVIDE STAINLESS STEEL BOLTS AND LOCK WASHERS ON ALL MECHANICAL GROUND CONNECTIONS. 2. ALL EQUIPMENT SURFACES TO BE BONDED TO GROUNDING SYSTEM SHALL BE STRIPPED OF ALL PAINT AND DIRT AT ANY POINT OF CONNECTION. CONNECTIONS TO VARIOUS METALS SHALL BE OF A TYPE AS TO PREVENT A GALVANIC OR CORROSIVE REACTION. AREA SHALL BE REPAINTED FOLLOWING BONDING. 3. ANY METALLIC ITEM WITHIN 6' OF ANY EQUIPMENT OR METALLIC INFRASTRUCTURE (RACKS, CABLE TRAY.. ETC.) OR GROUND CONDUCTORS MUST BE CONNECTED TO THE GROUNDING SYSTEM PER AT&T STANDARDS. 4. EXTERIOR, ABOVE GRADE GROUND CONNECTIONS SHALL BE FURNISHED WITH A LIBERAL PROTECTIVE COATING OF ANTI-OXIDATION COMPOUND. 5. ALL MATERIALS AND LABOR REQUIRED FOR THE GROUNDING SYSTEM AS INDICATED ON THE PLANS AND DETAILS, AND AS DESCRIBED HEREIN SHALL BE FURNISHED BY THE CONTRACTOR UNLESS OTHERWISE NOTED. 6. EXACT LOCATION OF GROUND CONNECTION POINTS SHALL BE DETERMINED IN FIELD. ADJUST LOCATIONS INDICATED ON PLANS ACCORDING TO ACTUAL EQUIPMENT LOCATIONS TO KEEP THE GROUND CONNECTION CABLES AS SHORT AND STRAIGHT AS PRACTICAL. 7. PROVIDE ALL ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS AS REQUIRED BY THE CURRENT EDITION OF THE NATIONAL ELECTRIC CODE, THE CURRENT EDITION OF THE NATIONAL ELECTRICAL SAFETY CODE AND AT&T STANDARDS. BONDING JUMPERS WITH APPROVED GROUND FITTINGS SHALL BE INSTALLED AT ALL RACEWAYS, EQUIPMENT ENCLOSURES, PULL BOXES, ETC. TO MAINTAIN GROUND CONTINUITY WHERE REQUIRED BY CODE. 8. ALL BURIED EQUIPMENT GROUND CONDUCTORS SHALL BE #2 AWG BARE, TINNED, SOLID COPPER UNLESS NOTED OTHERWISE ON THE DRAWINGS. E. INSPECTION/DOCUMENTATION 1. THE CONTRACTOR, UPON COMPLETION OF HIS WORK, SHALL PROVIDE AS-BUILT DRAWINGS. INFORMATION SHOULD BE GIVEN TO THE GENERAL CONTRACTOR FOR INCLUSION IN FINAL AS-BUILT SURVEY DOCUMENTS TO BE GIVEN TO THE OWNER. 2. CONTRACTOR SHALL SUPPLY DOCUMENTATION ATTESTING TO THE COMPLETE GROUND SYSTEM'S RESISTANCE TO GROUND (MAX. 5 OHMS). 3. AN ELECTRICAL INSPECTION SHALL BE MADE BY AN INSPECTING AGENCY APPROVED BY AT&T'S REPRESENTATIVE. CONTRACTOR SHALL COORDINATE ALL INSPECTIONS AND OBTAIN POWER COMPANY APPROVAL. 4. CONTRACTOR SHALL HAVE ATS AND GENERATOR RELAY INSTALLATION AND CONNECTIONS INSPECTED BY OTHERS TO ENSURE THAT UL LISTING FOR THAT EQUIPMENT IS NOT VOIDED. 230817 REQUIRED SPECIAL INSPECTIONS: 1. PER IBC 1705.4 SPECIAL INSPECTION OF MASONRY. (IF REQUIRED) CEC l. CEC (CALIFORNIA ELECTRICAL CODE)CBC GENERAL NOTES PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: N-1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 2621 S Birch St - 101119515 & 20182981 7/24/2024 TITLE SHEET MAIN - DYER FA#: 10086996 GENERATOR INSTALLATION PROJECT 30KW GENERAC DIESEL GENERATOR PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: T-1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY: JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t& GENERAL DYNA MICS Information Technology 09/30/25 JURISDICTION USE: D ATE SIGNED: 4/2 /2 4 SITE INFORMATION: SITE ADDRESS:2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 COUNTY:ORANGE COORDINATES:33.711743° / -117.869806° (FOR NAVIGATION ONLY) PROPERTY LANDLORD OR OWNER:HOOD, MICHAEL RODNEY TR M TAX ID #:410-391-03 ZONING:M-1 OCCUPANCY GROUP: U - UNMANNED CONSTRUCTION TYPE: II-B POWER COMPANY: SCE FLOOD ZONE:X A.D.A. COMPLIANCE:FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION at t& VICINITY MAP: SITE 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 N GOOGLE MAPS 2024 APPROVALS : AT&T MANAGER _____________________________________ _________ CONSTRUCTION MANAGER _____________________________________ _________ SITE ACQ. MANAGER _____________________________________ _________ PROPERTY OWNER _____________________________________ _________ LANDLORD _____________________________________ _________ R DIG LINE: THE PLANS SHOW SOME KNOWN SUBSURFACE STRUCTURES, ABOVE GROUND STRUCTURES, AND/OR EXISTING UTILITIES BELIEVED TO BE IN THE WORKING AREA. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL UTILITIES, PIPELINES AND OTHER STRUCTURES SHOWN OR NOT SHOWN ON THESE PLANS. ANY DAMAGE TO EXISTING UTILITIES SHALL BE REPAIRED TO THE SATISFACTION OF THE OWNER AND ENGINEER AT THE CONTRACTOR'S EXPENSE. AREA MAP: SITE GOOGLE MAPS 2024DO NOT SCALE DRAWINGS: CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS, CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THE SAME. CODE COMPLIANCE: ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF ALL GOVERNING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS ARE TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA FIRE CODE (CFC) 2022 INTERNATIONAL BUILDING CODE (IBC) 2021 NATIONAL ELECTRICAL CODE (NEC) 2020 NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 13,30,37,58,70,72,110,111 AMERICAN CONCRETE INSTITUTE (ACI) 318 AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222 TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 607 SHEET INDEX: SHEET DESCRIPTION T-1 TITLE SHEET N-1 GENERAL NOTES A-0 PARCEL SITE PLAN A-1 OVERALL SITE PLAN A-2 ENLARGED SITE PLAN A-3 ELEVATION VIEWS S-1 GENERATOR PAD DETAILS S-2 GENERAL STRUCTURAL DETAILS S-3 FENCE & GATE DETAILS S-4 COMPOUND DETAIL E-1 ELECTRICAL DETAILS E-2 ELECTRICAL DETAILS E-3 ELECTRICAL DETAILS E-4.0 <--> E-4.4 GENERATOR SPECIFICATIONS E-5.0 ATS SPECIFICATIONS E-5.1 CAM-LOCK BOX SPECIFICATIONS SCOPE OF WORK: INSTALL (1) ARTICLE 702 OPTIONAL STANDBY DIESEL GENERATOR (GENERAC SD030) WITH UL-142 BASE FUEL TANK ON CONCRETE PAD AND 200A ATS / CAMLOCK (GENERAC TAS200) WITHIN COMPOUND NEAR EXISTING AT&T EQUIPMENT SHELTER. INTEGRATE NEW GENERATOR WITH EXISTING SERVICE. NOTE: NO CHANGES OR ALTERATIONS TO THE TOWER, MOUNTS, ANTENNAS, FEEDLINES, ETC. IS PROPOSED AS A PART OF THIS SCOPE OF WORK. CONTACT INFORMATION: APPLICANT: AT&T MOBILITY 1375 CAMINO REAL STE 120 SAN BERNARDINO, CA 92408 PHONE: 951.534.8967 PROJECT MANAGER: GENERAL DYNAMICS WIRELESS SERVICES, LLC. PHONE: 318.833.4864 CONTACT: KEITH JEFFREYS LEASING / PERMITTING: BRIUS PHONE: 571.641.9084 CONTACT: BRYAN TRAN EMAIL: bryant@briustelecom.com ARCHITECTURE & ENGINEERING: GEOSTRUCTURAL, LLC. PO BOX 2621 BOISE, ID 83701 PHONE: 530.539.4787 CONTACT: DON GEORGE Bldg# 101119515 Elec# 20182981 APPROVALS: PLNG - HJacinto BLDG - CSG Consultant ELEC - CSG Consultant 2621 S Birch St - 101119515 & 20182981 7/24/2024 RADIATOR/EXHAUST/ FUEL END DISCHARGE BA T T E R Y B O X PO W E R C E N T E R & CO N T R O L S BO L T O N P A N E L S 5' V E N T RAD I U S 10 ' - 0 " 10 ' - 0 " 4'-0" 4'-0" 5' V E N T RAD I U S OVERALL SITE PLAN PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: A-1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 OVERALL SITE PLAN N 1SCALE: 1" = 30'-0" (11x17) PROJECT SITE, SEE SHEET A-2 FOR ENLARGED SITE PLAN PROPOSED GENERATOR LOCATION, SEE SHEET A-2 FOR ENLARGED SITE PLAN 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 TAX ID#: 410-391-03 NOTE: EVERYTHING SHOWN IS EXISTING UNLESS MARKED PROPOSED EXISTING CONDITIONS: THESE DRAWINGS WERE PRODUCED WITH INFORMATION PROVIDED BY THE CLIENT. LINES, EASEMENTS, AND SETBACKS SHALL BE VERIFIED PRIOR TO START OF CONSTRUCTION, GEOSTRUCTURAL DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINE, EASEMENTS AND SETBACKS. BUILDING CUMULATIVE VOLUME CALCULATIONS: THE PHYSICAL DIMENSIONS OF THE PROPOSED GENERATOR w/ ENCLOSURE AND BASE FUEL TANK ARE LESS THAN 250 CU. FT. IN VOLUME. BASE FUEL TANK = 106"x36"x25" = 55.2 CU. FT. GENERATOR BODY w/ ENCLOSURE = 94.8"x61.1"x38" = 127.4 CU. FT. TOTAL CUMULATIVE VOLUME OF GENSET = 55.2 + 127.4 = 182.6 CU. FT. GENSET USE, CEQA & BAAQMD EXEMPTION: THE PROPOSED GENERAC SD030 GENSET: * IS RATED AT 49 HP AT MAXIMUM RATED kW OUTPUT, * IS INSTALLED WITH AN ABOVE-GROUND DOUBLE-WALL SECONDARY CONTAINMENT BASE FUEL TANK WITH 190 USABLE (200 MAX) GALLONS OF FUEL, * USES ULTRA LOW SULFUR DIESEL FUEL (15 ppm SULFUR), * IS LIMITED TO 100 HOURS PER YEAR OF NON-EMERGENCY USE (TESTING & MAINTENANCE), * IS INSTALLED WITH A LEVEL 2 ACOUSTIC ENCLOSURE, WHICH BUFFERS SOUND OUTPUT TO A MAXIMUM OF 62 dB AT 7 METERS (~23 FEET), * IS COMPLIANT WITH APPLICABLE AIR QUALITY REGULATIONS, * IS EXEMPT FROM AIR QUALITY PERMITS IN MOST JURISDICTIONS UNDER THE PROVISIONS OF CLASS 1, SEC. 15301 OF THE CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA) GUIDELINES, * IS EXEMPT PER BAAQMD REG. 2, RULE 1, SEC. 2-1-114-2.2.1.; LESS THAN 50 BHP. P E AT&T LEASE AREAS EXISTING APPROXIMATE (91.6 SQ.FT.) LEASE AREA PROPOSED 4'-0"x10'-0" (40 SQ.FT.) GENERATOR LEASE AREA EXISTING LEASE AREA SIZES WERE OBTAINED FROM LEASE DOCUMENTS PROVIDED TO GEOSTRUCTURAL AND ARE SHOWN FOR REFERENCE ONLY. REFER TO FINAL LEASE DOCUMENTS FOR APPROVED EXISTING AND PROPOSED LEASE AREAS. E P PARCEL LINE PARCEL LINE PA R C E L L I N E ASPHALT PAVEMENT STORAGE MATERIAL PAVED PARKING LOT EXISTING MONOPOLE TOWER w/ AT&T ANTENNAS EXISTING WROUGHT-IRON FENCE EXISTING CONCRETE PREFAB EQUIPMENT SHELTER (OTHER CARRIER) 2621 S Birch St - 101119515 & 20182981 7/24/2024 RADIATOR/EXHAUST/ FUEL END DISCHARGE BA T T E R Y B O X PO W E R C E N T E R & CO N T R O L S BO L T O N P A N E L S 5' V E N T RAD I U S 10 ' - 0 " 10 ' - 0 " 4'-0" 4'-0" 5' V E N T RA D I U S 1ENLARGED SITE PLAN N SCALE: 1" = 5'-0" (11x17) UTILITY NOTE: THE UTILITIES AS SHOWN ON THIS SET OF DRAWINGS WERE DEVELOPED FROM RECORD INFORMATION. THE INFORMATION PROVIDED IS IMPLIED NOT INTENDED TO BE A COMPLETE INVENTORY OF THE UTILITIES IN THIS AREA. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION OF ALL UTILITIES (WHETHER SHOWN OR NOT) AND PROTECT SAID UTILITIES FROM ANY DAMAGE CAUSED BY CONTRACTOR'S ACTIVITIES. EXISTING CONDITIONS: THESE DRAWINGS WERE PRODUCED WITH INFORMATION PROVIDED BY THE CLIENT. LINES, EASEMENTS, AND SETBACKS SHALL BE VERIFIED PRIOR TO START OF CONSTRUCTION, GEOSTRUCTURAL DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINE, EASEMENTS AND SETBACKS. SCOPE OF WORK DETAILS: GENERAL: · NEW GENERAC DIESEL GENERATOR PROVIDED BY GENERAL DYNAMICS & INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS E-4.0, E-4.1, E-4.2. · NEW CONCRETE PAD PROVIDED & INSTALLED BY GENERAL CONTRACTOR. SEE SHEET S-1. · NEW GENERAC AUTOMATIC TRANSFER SWITCH PROVIDED BY GENERAL DYNAMICS & INSTALLED BY CONTRACTOR. SEE SHEETS S-2, E-5.0, E-5.1. · CONTRACTOR TO VERIFY ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. · CONTRACTOR SHALL RESTORE & REPAIR ANY DAMAGED AREAS CAUSED BY CONSTRUCTION TO ORIGINAL OR BETTER CONDITION. · INNER AND OUTER TANK TESTING DOCUMENTATION SHALL BE PROVIDED ONCE TANK IS IN PLACE ON SITE IN ACCORDANCE WITH NFPA 30. · A CALIBRATION CHART OF PERMANENT AND DURABLE CONSTRUCTION SHALL BE LOCATED AT THE FILL BOX. CONDUITS: · INSTALL PULL STRING IN EACH CONDUIT. · (2) NEW ELECTRICAL CONDUITS WITH CONDUCTORS TO BE INSTALLED FROM NEW GENERATOR TO NEW ATS. CONDUIT PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS E-1, E-2. · (2) NEW ELECTRICAL CONDUITS WITH CONDUCTORS TO BE INSTALLED FROM NEW GENERATOR TO AC PANEL. CONDUIT PROVIDED & INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS E-1, E-2. · (1) NEW ALARM CONDUIT & CABLING PROVIDED & INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS E-1, E-2. GROUNDING: · NEW EXOTHERMIC CONNECTION FROM EXISTING GROUND RING TO NEW MECHANICAL CONNECTION AT GENERATOR CHASSIS. GENERAL CONTRACTOR TO VERIFY LOCATION IN FIELD. LOCATE GROUND RODS NO MORE THAN 8'-0" APART. SEE SHEET E-3. R GENERATOR KEYED NOTES: PROPOSED AT&T 30KW DIESEL GENERATOR w/ SOUND ATTENUATED ENCLOSURE, NORMAL/EMERGENCY TANK VENTING AND BASE FUEL TANK. SEE SHEETS S-1, S-2, E-3. FUEL FILL SHALL BE PROVIDED WITH SPILL CONTROL, WITH A SOLID FILL CONNECTION, AND WITH OVERFILL PREVENTION FUEL TANK NORMAL AND EMERGENCY VENTS SHALL TERMINATE AT LEAST 12'-0" ABOVE THE ADJACENT GRADE. SEE SHEET S-2. NFPA 704 PLACARD AND OTHER SIGNAGE. SEE SHEET S-2. GEN 1 2 3 INT AC CON GEN 1 2 3 FIRE OFF ATS NOTE: EVERYTHING SHOWN IS EXISTING UNLESS MARKED PROPOSED ATS / EQUIPMENT KEYED NOTES: -FIRE EXTINGUISHER, (2A-20BC OR APPROVED EQUAL) PER CFC 906.3 -FIRE EXTINGUISHER CABINET (BFC-7009 OR APPROVED EQUAL), MOUNT TO CMU BLOCK WALL PER CFC 906.6 (5'-0" MAX. ABOVE GRADE) LOCKABLE EMERGENCY SHUTOFF SWITCH, MOUNT TO CMU BLOCK WALL PER CFC 906.9 (5'-0" MAX. ABOVE GRADE) PROPOSED ATS w/ CAMLOCK MOUNTED TO CMU BLOCK WALL WITH 36" FRONT CLEARANCE. SEE SHEET S-2. FIRE OFF ATS POWER ROUTING KEYED NOTES: EXISTING AC LOAD CENTER INTERCEPT EXISTING CONDUIT AND CONDUCTORS PRIOR TO AC PANEL AND RE-ROUTE THROUGH PROPOSED ATS (~50'). COORDINATE PATH WITH CONSTRUCTION MANAGER PROPOSED AT&T UNDERGROUND GENERATOR CONDUIT ROUTE (~15'). CONTRACTOR TO LOCATE EXISTING UTILITIES PRIOR TO EXCAVATION. SEE SHEETS E-1, E-2. SEE SHEET E-1 FOR SINGLE LINE DIAGRAM. AC INT CON PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: A-2 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 ENLARGED SITE PLAN INT 5' - 0 " 4'-0" 4' - 7 " AC C E S S C L E A R A N C E , T Y P . 36 " B R E A K E R S / A L T E R N A T O R 24 " I N T A K E / E X H A U S T HVAC UNIT EXISTING CONCRETE RAMP HVAC UNIT HVAC UNIT HVAC UNIT ASPHALT PAVED COMPOUND EXISTING MONOPOLE TOWER w/ AT&T ANTENNAS EXISTING WROUGHT-IRON FENCE EXISTING WROUGHT-IRON SWING GATE PA R C E L L I N E EXISTING PREFAB CONCRETE EQUIPMENT SHELTER (OTHER CARRIER) EXISTING AT&T EQUIPMENT SHELTER EXISTING ICE BRIDGE, TYP. ASPHALT PAVEMENT EXISTING CMU BLOCK WALL EXISTING HAND-HOLE PARCEL LINE STORAGE MATERIAL EXISTING EQUIPMENT H-FRAME CONCRETE STOOP CONTRACTOR TO SAW-CUT EXISTING PAVEMENT AS REQUIRED TO INSTALL CONCRETE PAD 5'-0" MIN. (~5'-3" PROVIDED) 2621 S Birch St - 101119515 & 20182981 7/24/2024 GRADE 0'-0" TOP OF VENTILATION PIPES 12' MIN. TOP OF GENERATOR 7'-9" GRADE 0'-0" PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: A-3 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 ELEVATION VIEWS PROPOSED AT&T DIESEL GENERATOR ANCHORED TO PROPOSED CONCRETE SLAB 2SCALE N.T.S.1SCALE N.T.S.EXISTING ELEVATION VIEW PROPOSED ELEVATION VIEW TOP OF TOWER60'± VENT PIPE, TYP. OF (3) EXISTING MONOPOLE TOWER (ANTENNAS NOT SHOWN) EXISTING PREFAB CONCRETE EQUIPMENT SHELTER (OTHER CARRIER) EXISTING AT&T EQUIPMENT SHELTER EXISTING CMU BLOCK WALL PROPOSED AT&T ATS w/ GEN PLUG AND EQUIPMENT MOUNTED TO EXISTING CMU WALL 2621 S Birch St - 101119515 & 20182981 7/24/2024 3G0 4' - 0 " 1'-0" BLOCKOUT 2' - 7 " BL O C K O U T 2" BA S E E X T E N T S P E R MA N U F A C T U R E R #4 U-BARS CONDUIT STUB-UP AREA; CONFIRM LOCATION & SIZE WITH MANUFACTURER (8) 5 8"Ø x 33 4" EMBED HILTI KWIK BOLT TZ2 STAINLESS STEEL EXPANSION ANCHOR (OR APPROVED EQUAL). REFERENCE ICC-ES ESR-4266 REPORT. INSTALLATION TORQUE = 60 FT-LB 6" MIN. BOLT ℄ TO EDGE A AB 10'-0" 9" BASE EXTENTS PER MANUFACTURER 7" OUTLINE OF GENERATOR FOOTPRINT SLAB REINF., SEE SECTION A-A 6" 41 4" HO L E D E P T H 1116"Ø HOLE (5 8"Ø BIT) B ANCHOR FRAME 3" GENERATOR PAD - SECTION B-B TYPICAL ANCHOR GENERATOR PAD DETAIL (10) #5 TRANSVERSE REBAR 2"± 4" CLR. 3" TYP. 8" CONCRETE MIN. (5) #5 LONGITUDINAL REBAR OUTLINE OF GENERATOR 3 4" CHAMFER, TYP. GENERATOR PAD - SECTION A-A #4 U-BARS CONDUIT STUB-UP AREA FLEXIBLE STUB CONDUITS. SEE SHEET E-2. CONCRETE PAD 13 4" CLR. TYP. LONGITUDINAL TR A N S V E R S E 9" CONTRACTOR TO RESTORE EXISTING CONDITIONS ON SITE, SLOPE AWAY AS REQUIRED 6" COMPACTED GRANULAR BASE COMPACTED SUBGRADE NOTE: IT IS ACCEPTABLE TO INSTALL AND UTILIZE A PRE-CAST GENERATOR PAD FOUNDATION SO LONG AS THE MINIMUM CONCRETE AND REINFORCING REQUIREMENTS DETAILED HEREIN ARE MET, AND PROVIDED SUB-GRADE SURFACE COMPACTION AND PREPARATION ARE PERFORMED ADEQUATELY IN ACCORDANCE WITH THIS PLAN. SCALE: 1/2"=1'-0"(11x17) 1"=1'-0" (24x36) SCALE: 1/2"=1'-0"(11x17) 1"=1'-0" (24x36) 33 4" EM B E D M E N T 6" 3" CONCRETE NOTES: 1.PRIOR TO EXCAVATION, CHECK THE AREA FOR UNDERGROUND FACILITIES. 2.ALL CONCRETE SHALL BE IN ACCORDANCE WITH CHAPTER 19 OF THE IBC & ACI 318, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE", LATEST EDITION & HAVE THE FOLLOWING PROPERTIES: A MINIMUM 28-DAY COMPRESSIVE STRENGTH (f'c) OF 4,000 PSI. B CEMENT SHALL BE "LOW-ALKALI" TYPE IIA (MODERATE SULFATE RESISTANCE, AIR ENTRAINING) CONFORMING TO ASTM C150. C MAXIMUM WATER/CEMENT RATIO OF 0.45 AND AIR-ENTRAINED 4% TO 7%. D CONCRETE PROPORTIONING SHALL BE DESIGNED BY AN APPROVED LABORATORY. TOLERANCES IN ACCORDANCE WITH ACI 117. COPIES OF CONCRETE MIX SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO PLACEMENT. E ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. USE ONLY AGGREGATES KNOWN NOT TO CAUSE EXCESSIVE SHRINKAGE. MAXIMUM AGGREGATE SIZE TO BE 3 4". F MAXIMUM SLUMP: REFER TO GEOTECHNICAL REPORT WHEN APPLICABLE. 3.FORMWORK FOR CONCRETE SHALL CONFORM TO ACI 347. TOLERANCES FOR FINISHED CONCRETE SURFACES SHALL MEET CLASS-C REQUIREMENTS. IN NO CASE SHALL FINISHED CONCRETE SURFACES EXCEED THE FOLLOWING VALUES AS MEASURED FROM NEAT PLAN LINES AND FINISHED GRADES: ± 1 4" VERTICAL, ± 1" HORIZONTAL. 4.CHAMFER ALL EXPOSED CORNERS AND FILLET ENTRANT ANGLES 3 4" U.N.O. 5.CONCRETE FINISHING: CONCRETE SURFACES SHALL BE FINISHED IN ACCORDANCE WITH ACI. PROVIDE ROUGH FINISH FOR ALL SURFACES NOT EXPOSED TO VIEW AND SMOOTH FINISH FOR ALL OTHERS, U.N.O. 6.STEEL REINFORCEMENT AND CONCRETE SHOULD BE PLACED IMMEDIATELY UPON COMPLETION OF THE FOUNDATION EXCAVATION. CONTRACTOR SHALL NOT ALLOW A COLD JOINT TO FORM IN THE CONCRETE. PORTION AT GRADE SHOULD BE FORMED. TEMPORARY CASING MAY BE REQUIRED TO PREVENT CAVING PRIOR TO CONCRETE PLACEMENT. REINFORCING STEEL NOTES: 1.ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615. VERTICAL/HORIZONTAL BARS SHALL BE GRADE 60; TIES OR STIRRUPS SHALL BE A MINIMUM OF GRADE 40. ALL REINFORCING STEEL SHALL HAVE 3" (± 3 8") OF CONCRETE COVER, U.N.O. 2.ALL BAR BENDS, HOOKS, SPLICES AND OTHER REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ACI 315. 3.ALL BARS SHALL BE SPLICED WITH A MINIMUM LAP OF 48 BAR DIAMETERS. LAP SPLICES OF DEFORMED BARS IN TENSION ZONES SHALL BE CLASS-B SPLICES. WELDING OF BARS IS NOT PERMITTED. 4.AT ALL CORNERS AND WALL INTERSECTIONS, PROVIDE BENT HORIZONTAL BARS TO MATCH THE HORIZONTAL REINFORCING STEEL. 5.PROVIDE VERTICAL DOWELS IN FOOTINGS AND AT CONSTRUCTION JOINTS TO MATCH VERTICAL REINFORCING BAR SIZE AND SPACING. 6.ACI-APPROVED PLASTIC-COATED BAR CHAIRS OR PRECAST CONCRETE BLOCKS SHALL BE PROVIDED FOR SUPPORT OF ALL GRADE-CAST REINFORCING STEEL & SHALL BE SUFFICIENT IN NUMBER TO PREVENT SAGGING. METAL CLIPS OR SUPPORTS SHALL NOT BE PLACED IN CONTACT WITH THE FORMS OR THE SUB-GRADE. 7.DOWELS AND ANCHOR BOLTS SHALL BE WIRED OR OTHERWISE HELD IN CORRECT POSITION PRIOR TO PLACING CONCRETE. IN NO CASE SHALL DOWELS OR ANCHOR BOLTS BE "STABBED" INTO FRESHLY-POURED CONCRETE. MECHANICAL ANCHOR NOTES: 1.HILTI PRODUCTS MUST BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS, AS INCLUDED IN THE PACKAGING. 2.CONTRACTOR SHALL AVOID DRILLING HOLES IN VERTICAL/HORIZONTAL REINFORCING BARS. 3.HOLES MUST BE WIRE BRUSHED AND BLASTED WITH COMPRESSED AIR PRIOR TO INSTALLATION. TEMPERATURES/METHODS/WORKING TIME/ETC. ARE TO BE IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. FOUNDATION & SOIL NOTES: 1.FOUNDATION DESIGN BASED ON PRESUMPTIVE MINIMUM SOIL PARAMETERS (ALLOWABLE BEARING = 1,500 PSF; ALLOWABLE PASSIVE SLIDING = 100 PSF/FT) IN ACCORDANCE WITH THE IBC. 2.THE EXCAVATION SHALL BE INSPECTED PRIOR TO THE PLACEMENT OF CONCRETE AND THE CONTRACTOR SHALL PROVIDE A NOTICE OF INSPECTION FOR THE BUILDING INSPECTOR FOR REVIEW AND RECORDS PURPOSES. 3.THE CONTRACTOR SHALL DETERMINE THE MEANS AND METHODS NECESSARY TO SUPPORT THE EXCAVATION DURING CONSTRUCTION. 4.ALL FOUNDATIONS TO BE PLACED ON FIRM, UNDISTURBED, INORGANIC MATERIAL. PROOF ROLL SUB-GRADE PRIOR TO PLACING CONCRETE WHERE THE MATERIAL HAS BEEN DISTURBED BY EQUIPMENT. UNACCEPTABLE/DISTURBED MATERIAL SHALL BE OVER-EXCAVATED AND REPLACED WITH "LEAN CONCRETE FILL" OR REPLACED WITH STRUCTURAL BACKFILL. 5.STRUCTURAL BACKFILL SHALL BE GRANULAR FREE-DRAINING MATERIAL FREE OF DEBRIS, ORGANICS, REFUSE AND OTHERWISE DELETERIOUS MATERIALS. MATERIAL SHALL BE PLACED IN LIFTS NO GREATER THAN 6" IN DEPTH AND COMPACTED TO 95% OF MAXIMUM DENSITY AS DETERMINED PER ASTM D1557 (MODIFIED PROCTOR). CBC 2,500 AND CBC. 1,000 2" (2) #4 U-BARS (THIS LOCATION)2'-0" GENERATOR PAD DETAILS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: S-1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 STRUCTURAL DESIGN NOTES: ALL LOADS DERIVED FROM REQUIREMENTS OF THE IBC 2021, CBC 2022, ASCE 7 & ANSI TIA-222. BUILDING & COMMUNICATION STRUCTURES: (33.711743° / -117.869806°) 1.WIND LOADS: IBC 2021 , CBC 2022 & ASCE 7-16 w/ SUPPLEMENT 1 V = 95 MPH ULTIMATE WIND SPEED RISK CATEGORY = II; EXPOSURE CATEGORY = C; TOPOGRAPHIC CATEGORY = 1. IMPORTANCE FACTOR = 1.0. 2.SEISMIC LOADS: IBC 2021, CBC 2022 & ASCE 7-16 w/ SUPPLEMENT 1 RISK CATEGORY = II; SITE CLASS = D - DEFAULT. SS = 1.279 ; S1 = 0.458 ; SDS = 1.023 ; ap = 1.0 ; Rp = 2.5 9" 4" (8) 5 8"Ø x 518" EMBED SIMPSON STRONG BOLT 2 STAINLESS STEEL EXPANSION ANCHOR (OR APPROVED EQUIVALENT) REFERENCE ICC-ES REPORT ESR-3037 80 6" M I N . 5 18" 5 3 8" 2621 S Birch St - 101119515 & 20182981 7/24/2024 G DOUBLE WALL FUEL TANK BASE SPECIFICATION: REF: AT&T 30KW GENERATOR PACKAGE UL REGISTRATION NUMBER: MH 18459 UL 142 DOUBLE WALL FUEL TANK BASE SPECIFICATION FUEL TANK BASE CONSTRUCTION: + BE CONSTRUCTED IN ACCORDANCE WITH UNDERWRITERS LABORATORIES STANDARD UL-142. BE CONSTRUCTED IN ACCORDANCE WITH FLAMMABLE COMBUSTIBLE LIQUIDS CODE, NFPA 30; THE STANDARD FOR INSTALLATION USE OF STATIONARY COMBUSTIBLE ENGINE GAS TURBINES, NFPA 37; AND THE STANDARD FOR EMERGENCY STANDBY POWER SYSTEMS, NFPA 110. +MINIMUM ANCHOR QUANTITY PER MANUFACTURER OR THIS PLAN SET; WHICHEVER IS LARGER. SUB BASE TANK TESTING: +PRIMARY TANK & SECONDARY CONTAINMENT BASIN SECTIONS SHALL BE PRESSURIZED AT 3-5 PSI AND LEAK-CHECKED TO ENSURE INTEGRITY OF SUB BASE WELD SEAMS PER UL-142 STANDARDS FUEL FILL: 2.5 - 5 GALLON SPILL CONTAINMENT WITH ALARM +40% REMAINING FOR ALARM +20% REMAINING FOR SHUT-DOWN FACTORY PRE-SET AT 90% FULL FOR ALARM FUEL CONTAINMENT BASIN: + SUB BASE TANK SHALL INCLUDE A WELDED STEEL CONTAINMENT BASIN, SIZED AT A MINIMUM OF 110% OF THE TANK. CAPACITY TO PREVENT ESCAPE OF FUEL INTO THE ENVIRONMENT IN THE EVENT OF A TANK RUPTURE. A FUEL CONTAINMENT BASIN LEAK DETECTOR SWITCH SHALL BE PROVIDED. 15" x 15" SIGN PLACE ON (2) VISIBLE SIDES OF PROPOSED GENERATOR TANK 11" x 11" SIGN PLACE ON (2) VISIBLE SIDES OF PROPOSED GENERATOR TANK 6.5" x 3" SIGN DIESEL TANK CHECKLIST: READILY ACCESSIBLE MANUAL SHUTOFF VALVES SHALL BE INSTALLED ON SUPPLY PIPING AT THE POINT OF USE AND THE TANK (IFC 5003.2.2.1) SECONDARY CONTAINMENT-TYPE TANKS SHALL BE UL LISTED, UL-142, AND COMPLY WITH ALL OF THE FOLLOWING REQUIREMENTS; OTHERWISE TRADITIONAL SPILL CONTROL OR SECONDARY CONTAINMENT MEASURES, SUCH AS DIKING, SHALL BE UTILIZED (NFPA 30 22.11.4) +CAPACITY OF DIESEL TANK SHALL NOT EXCEED 50,000 GAL. +PIPING CONNECTIONS SHALL BE ABOVE THE LIQUID LEVEL +MEANS SHALL BE PROVIDED TO PROTECT RELEASE OF LIQUID BY SIPHON FLOW. +MEANS TO DETERMINE LIQUID LEVEL IN TANK SHALL BE PROVIDED TO DRIVER. +MEANS TO PREVENT OVERFILLING BY AN ALARM AT 90% CAPACITY AND AUTOMATICALLY STOPPING DELIVERY OF LIQUID TO THE TANK AT 95% CAPACITY. +SPACING BETWEEN ADJACENT TANKS SHALL NOT BE LESS THAN 3'. +TANK SHALL BE PROTECTED AGAINST DAMAGE FROM VEHICLES. +INTERSTITIAL SPACE SHALL HAVE EMERGENCY VENTING. +INTEGRITY OF SECONDARY CONTAINMENT SHALL BE ESTABLISHED. +THE SECONDARY CONTAINMENT SHALL WITHSTAND THE HYDROSTATIC HEAD OF THE MAXIMUM AMOUNT OF LIQUID STORED IN THE PRIMARY TANK. TANK LABELING AND PROTECTIONS: THE FOLLOWING SIGNS AND LABELS SHALL BE AFFIXED TO THE TANK. +"DIESEL FUEL - NO SMOKING" (IFC 5703.5 & IFC 5003.7.1) +NFPA 704 PLACARD (IFC 5003.5) +EH&S +AT&T MOBILITY SIGN #3 CRASH PROTECTION COMPLYING WITH IFC 312 SHALL BE PROVIDED (IFC 5003.9.3) (IF APPLICABLE) GENERATOR FEATURES: GENERATORS SHALL BE UL 2200 LISTED AND COMPLY WITH NFPA 37 AND NFPA 110. (IFC 1203.1.1) INSTALLATIONS SHALL HAVE A LABELED REMOTE MANUAL STOP (NFPA 110 5.6.5.6 & 5.6.5.6.1 AND NFPA 37 9.2.1.1) NEPA NOTES: 1.CONSTRUCTION, INSTALLATION, MAINTENANCE, & OPERATIONAL TESTING OF EPSS SHALL COMPLY WITH THE LATEST ADOPTED EDITION OF NFPA 110. 2.ALL ELECTRICAL WORK SHALL COMPLY WITH LATEST ADOPTED EDITION OF NFPA 70 - NATIONAL ELECTRICAL CODE. FUEL TANK NOTES: THE TANK SHALL BE MANUFACTURED WITH THE FOLLOWING: -INTERSTITIAL ELECTRONICALLY MONITORED RUPTURE BASIN -ALARM TO MONITOR THE SPACE BETWEEN THE PRIMARY AND SECONDARY TANK. -OVERFILL ALERT TO VISUALLY WARN WHEN THE TANK IS FILLED UPON CAPACITY. -OVERSPILL CONTAINMENT AT FILL PORT TO PREVENT SPILL OF FUEL DURING FILLING OPERATIONS. -2.5/5 GALLON OVERSPILL CONTAINMENT W/ LOCKABLE CAP. REQUIRED LABELING & SIGNAGE CONTRACTOR TO PROVIDE REQUIRED SIGNAGE FOR ELECTRICAL PANELS, DISCONNECTS, TRANSFER SWITCHES, ETC. PER NATIONAL ELECTRICAL CODE ARTICLE 702.7 SECTION A-A 3 8"Ø STAINLESS STEEL U-BOLT w/ NUT AND LOCK-WASHER. MAX. U-BOLT TORQUE = 30 FT-LBS. GALVANIZED H-FRAME POST 3'-0" MIN. (4'-0" MIN. IF SUB PANEL REQ'D) 6' - 0 " PIPE CAP, TYP. H-FRAME DETAIL (IF REQUIRED) A A 6" MAX. 15 8" P1000T UNISTRUT MEMBER INSTALLED TO H-FRAME POSTS. APPLY TWO COATS OF COLD-GALV COMPOUND TO "CUT" ENDS. INSTALL VINYL END CAPS. (TO BE FIELD LOCATED AS REQUIRED) 3- 0 " ( M I N . ) O R P E R LO C A L F R O S T D E P T H 4" 49 . 4 " ( V E R I F Y W / AT S M A N U F . ) NEW PIPE2.5STD (2.875"OD SCHEDULE 40) H-FRAME POST, TYP. (ALTERNATE INSTALLATION: CONTRACTOR MAY ELECT TO USE EXISTING H-FRAME POST IF AVAILABLE) 2" AUTOMATIC TRANSFER SWITCH CA M - L O C K BO X EMERGENCY SHUTOFF SWITCH 12"Ø CONCRETE FOOTING (f'c=2,500 psi) ⅊3 4x7x7 (4) 1 2"Ø x 33 4" EMBED HILTI KWIK BOLT TZ2 STAINLESS STEEL EXPANSION ANCHOR (OR APPROVED EQUAL). REFERENCE ICC-ES ESR-4266 REPORT. 3.75" 3/16 POST FOOT PAD FOR SLAB-TOP INSTALLATION (IF APPLICABLE) 1" DRY PACK, IF REQ'D 5"3"(MIN.) TO EDGE OF SLAB 1" CROWN OR FOOTPAD #2 SOLID, TINNED BARE COPPER WIRE CADWELD POSTS TO GROUND RING GROUND RING ATS LOCATION NOTE: ATS LOCATION SHOWN IN PLANS IS THE BEST AVAILABLE BASED ON THE INFORMATION PROVIDED. ALTERNATIVE LOCATION MAY BE REQUIRED AND SHALL BE APPROVED BY CONSTRUCTION MANAGER AND/OR LANDLORD. THIS DETAIL PROVIDES ALTERNATIVE METHODS OF INSTALLATION (NOT ALL DETAILS MAY BE USED). [MAX. ATS + CAM-LOCK WEIGHT = 210 LBS] GRADE PROPOSED GENERATOR W/ DIESEL FUEL TANK ON CONCRETE PAD VENT PIPE, TYP. OF (3) 12 ' M I N . GENERATOR VENTING DETAIL VENT BRACING TO ENCLOSURE PER MANUFACTURER ATS MOUNTING DETAIL 15" x 12" SIGN PLACE ON (2) VISIBLE SIDES OF PROPOSED GENERATOR TANK UNISTRUT WALL ATTACHMENT: WALL CONSTRUCTION TYPE FASTENER HOLLOW, AT STUD 3/8" DIA. x 2-1/2" EMBED SAE J429 GR.1 LAG SCREW CONCRETE BLOCK (HOLLOW) 3/8" DIA. HILTI HY-270 (ESR-4143) W/ SCREEN, MINIMUM EMBEDMENT 2-3/8" CONCRETE (SOLID) 3/8" DIA. HILTI HY-200 (ESR-3187), MINIMUM EMBEDMENT 2-3/8" NOTES: 1. USE GALVANIZED OR STAINLESS STEEL HARDWARE FOR WALL MOUNT AND CONNECTION OF CHANNELS 2. GC SHALL USE NON-SHRINKING CAULK TO WEATHER SEAL ALL PENETRATIONS INTO OR THROUGH WALL PLACE ON (2) VISIBLE SIDES OF PROPOSED GENERATOR TANK 2 01 COLOR: BLUE COLOR: RED COLOR: YELLOW FOR FUEL & OTHER ENVIRONMENTAL EMERGENCIES CALL EH&S 1-800-566-9347 (1-800-KNOW-EHS) AT&T MOBILITY COMBUSTIBLE NO SMOKING NO OPEN FLAMES FUEL TANK CAPACITY 190 GALS DIESEL FUEL **SEE SHEETS E-4.3, E-4.4 FOR VENT PIPES, FUEL FILL, SPILL & ALARM COMPONENTS CFC CFC CFC CFC CFC CFC CALIFORNIA 18" ( V E R I F Y w / MAN U F . ) 49 . 4 " ( V E R I F Y w / MA N U F A C T U R E R ) MOUNTING TAB, TYP. OF (4). INSTALL 3 8 "Ø STAINLESS STEEL THRU-BOLTS w/ NUTS AND LOCK-WASHERS. MAX. THRU-BOLT TORQUE = 30 FT-LBS. NEW AUTOMATIC TRANSFER SWITCH w/ CAM-LOCK MOUNTED TO NEW UNISTRUT RAILS w/ THRU-BOLTS. [CAM-LOCK IS SECURED TO ATS BODY AND NOT ATTACHED TO UNISTRUT.] CAM-LOCK NOT SHOWN FOR CLARITY. 1-5/8" P1000T UNISTRUT MOUNTED TO WALL OR TO NEW H-FRAME POSTS W/ FASTENER PER ATTACHMENT TABLE ABOVE AT EACH END NEW MECHANICAL CONNECTION WITH #2 AWG TO EXISTING GROUND RING, SEE SHEET E-3 INS T A L L T O P OF A T S A T 5'-9" A B O V E GRA D E M A X . MAX. A T S + C A M - L O C K WEIG H T = 2 1 0 L B S GENERAL STRUCTURAL DETAILS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: S-2 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 2621 S Birch St - 101119515 & 20182981 7/24/2024 SINGLE LINE DIAGRAM ALL ELECTRICAL WORK CONDUCTED ON PANELS TO BE VERIFIED WITH CONSTRUCTION MANAGER AND CONDUCTED BY AN APPROVED ELECTRICAL CONTRACTOR LICENSED IN THE STATE. TYP 1 CONDUIT / WIRE SCHEDULE: NO.FROM TO WIRES GROUND CONDUIT SIZE FUNCTION NORMAL POWER SOURCE AUTOMATIC TRANSFER SWITCH (3) W/C (1) W/C (1) W/C NORMAL POWER FEEDER TO ATS (CUT BACK EXISTING) AUTOMATIC TRANSFER SWITCH LOAD CENTER (3) W/C (1) W/C (1) W/C POWER FEEDER FROM ATS TO PANELS GENERATOR AUTOMATIC TRANSFER SWITCH (3) W/C (1) W/C (1) W/C STANDBY POWER FEEDER TO ATS AUTOMATIC TRANSFER SWITCH GENERATOR (2) W/C (1) W/C (1) W/C START CIRCUIT LOAD CENTER (DISTRIBUTION CENTER) GENERATOR (2) W/C (2) W/C (1) W/C (1) W/C (1) W/C (1) W/C CKT FOR GEN BLOCK HEATER & BATTERY HEATER, CKT FOR BATTERY CHARGER, GENERATOR THROUGH ATS TO ALARM BLOCK 12-PAIR 24 AWG OR 2EA 6-PAIR CAT5 N/A 1" ALARM CABLES (1) 12 PAIR 24 AWG. PROVIDE 24" OF SLACK CABLE. FINAL PUNCH DOWN IS BY AT&T TECH. LABEL ALL WIRES AUTOMATIC TRANSFER SWITCH ALARM BLOCK (2) 12-PAIR 24 AWG OR (2) 6-PAIR CAT5 (1) 1-PAIR 24AWG N/A 1" ALARM CABLES (1) 12 PAIR 24 AWG (RUN THRU INTERIOR OF SHELTER OR GROUND EQUIPMENT & INTO ALARM BOX). PROVIDE SINGLE PAIR FOR COMMERCIAL POWER FAIL ALARM. PROVIDE 24" OF SLACK CABLE. FINAL PUNCH DOWN IS BY AT&T TECH. LABEL ALL WIRES CAM-LOCK BOX AUTOMATIC TRANSFER SWITCH (3) W/C (1) W/C (1) W/C STANDBY POWER FEEDER TO ATS (W/C) = SEE WIRE/CONDUIT SIZING TABLE FOR VALUES 1 2 3 4 5 6 7 8 ALARM WIRE IDENTIFICATION CHART: WIRE ALARM BROWN BROWN / WHITE GENERATOR RUNNING GREEN GREEN / WHITE CRITICAL FAULT BLUE BLUE / WHITE MINOR FAULT ORANGE ORANGE / WHITE LOW FUEL BROWN * BROWN / WHITE *FUEL LEAK *CAT5 CABLE ONLY, FROM 2ND CAT5 CABLE EXISTING DISTRIBUTION PANEL NEW 66 BLOCK FOR GENERATOR ALARM CIRCUITS (ON EXISTING TELCO BOARD) CONTRACTOR SHALL NOT SUBMIT BIDS OR PERFORM CONSTRUCTION WORK ON THIS PROJECT WITHOUT ACCESS TO THE CURRENT COMPLETE SET OF DRAWINGS LISTED IN THE TITLE-SHEET INDEX. EXISTING 200A MAIN SERVICE DISCONNECT M G N NEW ARTICLE 702 30 KW GENERATOR 120/240, 1PH, 60Hz G 150A EXISTING 120/240, 1PH, 200A DISTRIBUTION PANEL AT EQUIPMENT EQUIPMENT AREA INTERCEPT EXISTING CONDUIT AND CONDUCTORS PRIOR TO MAIN PANEL AND RE-ROUTE TO NEW ATS NEW CAM-LOCK BOX FOR PORTABLE GENERATOR CONNECTION 20A 20A 7 PANEL w/ ROOM FOR BREAKERS (2) NEW 20A WITH ADEQUATE KAIC RATING FOR AFC AT PANEL PANEL NOTES: 1.CONTRACTOR TO LABEL WIRES WITH P-TOUCH OR SIMILAR LABELS ONLY. ABSOLUTELY NO HANDWRITTEN LABELS. 2.CONTRACTOR SHALL PERFORM A POWER STUDY ON EXISTING AC PANEL PRIOR TO INSTALLING, CHANGING, ALTERING, OR REMOVING ANY BREAKER. NO WORK SHALL BE COMPLETED ON AC PANEL WITHOUT PROPER INSPECTOR OR ENGINEER APPROVED DOCUMENTATION CONFIRMING CAPACITY ON SITE. ALL WORK SHALL CONFORM TO NEC VERSION ENFORCED BY A.H.J. AT TIME OF INSTALLATION. 3.CONTRACTOR SHALL VERIFY THAT THE MAXIMUM DEMAND FOR ALL CONNECTED EQUIPMENT AT THIS SITE AS CALCULATED PER NEC DOES NOT EXCEED THE GENERATOR OUTPUT CIRCUIT BREAKER RATING. (SEE NOTE #4 ALSO.) 4.IF MAXIMUM DEMAND OF GENERATOR OUTPUT CIRCUIT BREAKER RATING AS CALCULATED PER NEC IS CONTINGENT ON THE TWO HVAC UNITS NOT OPERATING CONCURRENTLY, THEN CONTRACTOR SHALL VERIFY THAT THE HVAC LEAD/LAG CONTROLLER IS CONFIGURED TO PREVENT CONCURRENT OPERATION. IF NOT, THEN CONTRACTOR SHALL RECONFIGURE IT AS NEEDED TO PREVENT TRIPPING THE CIRCUIT BREAKER. 5.SEE REQUIRED LABELING & SIGNAGE; SHEET S-2. 3 6 4 5 5 1 2 8 WIRE/CONDUIT SIZING: FEEDER MAX 1-WAY LENGTH IN FEET WIRE SIZE 150A OCP 120/240V 1P 150A OCP 120/208V 1P 150A OCP 208Y/120V 3P 200A OCP 120/240V 1P 200A OCP 120/208V 1P 200A OCP 208Y/120V 3P GROUND WIRE SIZE CONDUIT SIZE 1/O 192 166 192 ---#4 1-1/2" 2/O 227 196 227 ---#4 2" 3/O 284 246 284 213 185 213 #4 2" 4/O 337 292 337 253 220 254 #4 2" 250 KCMIL 378 328 378 284 246 284 #4 2-1/2" 300 KCMIL 423 367 423 318 275 318 #3 2-1/2" 350 KCMIL 471 408 471 354 307 354 #2 2-1/2" 400 KCMIL 510 442 510 383 332 383 #2 3" 500 KCMIL 581 503 581 436 378 436 #1 3" 600 KCMIL 625 541 625 469 406 469 1/O 3-1/2" 750 KCMIL 694 601 694 521 451 521 2/O 3-1/2" 1000 KCMIL 781 677 781 586 508 586 3/O 4" FEEDER MAXIMUM LENGTH VALUES SHOWN ARE FOR MAX. FEEDER VOLTAGE DROP OF 2.5%. NOTE THAT A 30KW GENERATOR REQUIRES NO MORE THAN 150A OCP. MAX. ONE-WAY LENGTH VS. WIRE SIZE FOR 20A CKT, AND NEC REQ'D INCREASED GROUND WIRE SIZE - BELOW GROUND WIRE SIZE DISTANCE GROUND WIRE SIZE CONDUIT SIZE #12 0 - 51 FT #12 1" #10 52 - 85 FT #10 1" #8 86 - 130 FT #8 1" #6 131 - 203 FT #6 1" FOR LONG RUNS, PER NEC 300.3(B)(1), FOR CONDUCTORS 1/O AND LARGER, CONTRACTOR MAY ELECT TO INSTALL EQUIVALENT SETS OF PARALLEL CONDUCTORS (UPSIZE GROUND WIRE AND CONDUIT ACCORDINGLY). SMALLER CONDUCTORS REQUIRING UPSIZING MUST BE REPLACED w/ ADEQUATELY SIZED LARGER CONDUCTORS. NOTE: ALL CONDUCTORS TO BE COPPER UNLESS NOTED OTHERWISE. ATS POLE NOTE: NEW ATS/CAMLOCK ARE CONFIGURABLE FOR SINGLE OR THREE PHASE OPERATION. IN SINGLE PHASE INSTALLATIONS, 3-POLE ATS TO BE INSTALLED WITH ONE POLE NOT CONNECTED (UNUSED) AND TO BE CONFIGURED FOR DUAL-POLE USE. NEUTRAL SHALL NOT BE SWITCHED. GENERATOR NEUTRAL SHALL NOT BE BONDED TO GROUND AT THE GENERATOR. IT SHALL BE SOLIDLY CONNECTED THROUGH THE ATS, WITH NO SWITCHING DEVICE INSERTED IN THE CONDUCTOR, TO THE UTILITY SERVICE NEUTRAL. (OPEN TRANSITION, FLOATING NEUTRAL AT GENERATOR) THIS GENERATOR IS NOT INTENDED TO BE A SEPARATELY DERIVED SYSTEM. EXISTING METER EXISTING MAIN SERVICE FEED 200A 200A BOND TO EXISTING SITE LIGHTNING PROTECTION GROUNDING SYSTEM USING #2 AWG BARE SOLID TINNED COPPER GROUND PROTECTED IN RIGID OR INTERMEDIATE METAL CONDUIT (RMC/IMC) OR RIGID PVC CONDUIT, TYP. IF METALLIC IS USED, CONDUCTOR MUST BE BONDED TO BOTH ENDS OF CONDUIT. NEW LOCKABLE EMERGENCY SHUTOFF SWITCH NEW 120/240, 1PH, 60 Hz 200A NEMA 3R ATS RATED 25kAic, SEE ATS POLE NOTE. CEC CEC CEC CEC CEC *CONTRACTOR TO UTILIZE NEXT AVAILABLE IN SEQUENCE SINGLE BREAKER POSITION FOR GENERATOR, BATTERY CHARGER, BATTERY HEATER AND BLOCK HEATER ELECTRICAL DETAILS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: E-1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 EXISTING PANEL SCHEDULE INFORMATION WAS NOT AVAILABLE AT THE TIME OF DRAWING CREATION. SCOPE OF WORK REQUIRES (2) OR (3) PROPOSED SINGLE POLE, 20A BREAKERS, ONE EACH FOR CONDUIT CALLOUT NUMBER 5 ON THE SINGLE LINE DIAGRAM. UTILIZE EMPTY OR SPARE SPACES ON EXISTING PANELBOARD IF POSSIBLE. (3) 3/O (1) #4 (1) 2" (3) 3/O (1) #4 (1) 2" (3) 1/O (1) #4 (1) 2" (2) #10 (1) #10 (1) 1" (2) #12 (1) #12 (1) 1" (2) #12 (1) #12 (1) 1" (3) 3/O (1) #4 (1) 2" 2621 S Birch St - 101119515 & 20182981 7/24/2024 G CONDUIT COUPLING SLIP JOINT (IF REQUIRED PER NEC) CONDUIT ELBOW CONDUIT PLUG FOR SPARE CONDUIT PROPOSED CONDUIT U.L. SYSTEM NO. C-AJ-1150 CONDUIT THROUGH BEARING WALL SIMILAR TO U.L. DESIGN NO. U902 F RATING = 3 HR T RATING = O HR 1.FLOOR OR WALL ASSEMBLY : MINIMUM 4-1/2" THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS*. MAX DIAMETER OF OPENING IS 4". (SEE CONCRETE BLOCKS 9CATZ) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS. 2.THROUGH PENETRATIONS : ONE METALLIC PIPE OR CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. THE ANNULAR SPACE SHALL BE MINIMUM 0". (POINT CONTACT) TO MAXIMUM 1-3/8". THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR CONDUITS MAY BE USED: A. STEEL PIPE-NOMINAL 6" DIAMETER (OR SMALLER) SCHEDULE 40 (OR HEAVIER) STEEL PIPE B. IRON PIPE-NOMINAL 6" DIAMETER (OR SMALLER) CAST OR DUCTILE IRON PIPE. C. CONDUIT - NOMINAL 4" DIAMETER (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR NOMINAL 3-1/2" DIAMETER (OR SMALLER) STEEL CONDUIT. 3.PACKING MATERIAL: MINIMUM 6" THICKNESS OF MIN 4.0 PCF MINERAL WOOL BATTING INSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. 4.FILL, VOID, OR CAVITY MATERIAL*: SEALANT: MINIMUM 1/4" THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF FLOOR AND WITH BOTH SURFACES OF WALL. AT THE POINT CONTACT LOCATION BETWEEN PIPE AND CONCRETE, A MINIMUM 1/2" DIAMETER BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE CONCRETE/PIPE INTERFACE ON THE TOP SURFACE OF FLOOR AND ON BOTH SURFACES OF WALL. W-RATING APPLIES ONLY WHEN CP601S OR CP604 SEALANT IS USED. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC. : CP601S, CP604, CP606, OR FS-ONE SEALANT. * BEARING THE UL CLASSIFICATION MARK A A 4 2 3 2 4 4 NOTE: 1.IF EXISTING CONSTRUCTION VARIES FROM THIS DETAIL, AN EQUAL 3-HR U.L. PENETRATION APPROPRIATE FOR THE EXISTING WALL TYPE SHALL BE CONSTRUCTED 2.GC SHALL USE NON-SHRINKING CAULK TO WEATHERSEAL ALL PENETRATIONS INTO OR THRU SHELTER WALL. OUTER WALL PENETRATION DETAIL (IF APPLICABLE) UTILITY TRENCH SECTION (IF APPLICABLE) SLIP JOINT DETAIL (IF APPLICABLE) CONDUIT NOTES: 1.VERIFY WIRE AND CONDUIT QUANTITY & SIZES WITH GENERATOR MAKE & MODEL # PRIOR TO INSTALLATION. VERIFY ELECTRICAL REQUIREMENTS WITH LOCAL UTILITY PROVIDER. 2.ALL CONDUIT ABOVE GRADE OR IN AREAS OF HIGH TRAFFIC SHALL BE SCH 80 PVC. 3.PROVIDE SCH 40 PVC CONDUIT BELOW GRADE EXCEPT AS NOTED BELOW. 4.PROVIDE SCH 80 PVC CONDUIT AND ELBOWS AT STUB UP LOCATIONS (I.E. SERVICE POLE, BTS EQUIPMENT, ETC.) 5.INSTALL UTILITY PULLBOXES PER NEC. BACKFILL MATERIAL COMPACTED TO 95% RELATIVE DENSITY PER STANDARD PROCTOR COMPACTED SAND TO 95% RELATIVE DENSITY PER STANDARD PROCTOR 26 " M I N 30 " M A X 1' - 0 " 1' - 0 " 1'-6" 8" UNDISTURBED SOIL ELECTRICAL CONDUIT(S) CONDUIT NOTES: 1.VERIFY WIRE AND CONDUIT QUANTITY & SIZES WITH GENERATOR MAKE & MODEL # PRIOR TO INSTALLATION. VERIFY ELECTRICAL REQUIREMENTS WITH LOCAL UTILITY PROVIDER. 2.ALL CONDUIT ABOVE GRADE OR IN AREAS OF HIGH TRAFFIC SHALL BE SCH 80 PVC. 3.PROVIDE SCH 40 PVC CONDUIT BELOW GRADE EXCEPT AS NOTED BELOW. 4.PROVIDE SCH 80 PVC CONDUIT AND ELBOWS AT STUB UP LOCATIONS (I.E. SERVICE POLE, BTS EQUIPMENT, ETC.) 5.INSTALL UTILITY PULLBOXES PER NEC. SECTION A-A CONTRACTOR SHALL NOT SUBMIT BIDS OR PERFORM CONSTRUCTION WORK ON THIS PROJECT WITHOUT ACCESS TO THE CURRENT COMPLETE SET OF DRAWINGS LISTED IN THE TITLE-SHEET INDEX. ELECTRICAL WARNING TAPE CONTRACTOR TO MATCH EXISTING GRADE CONDITIONS AFTER TRENCH PLACEMENT AND COMPACTION (FOR PAVEMENT) CONTRACTOR TO SAW-CUT AND REMOVE EXISTING PAVEMENT. UPON REPLACEMENT, CONTRACTOR TO MATCH EXISTING PAVEMENT THICKNESS, PLACEMENT DETAILS AND DRAINAGE CONDITIONS AFTER TRENCH PLACEMENT AND COMPACTION GALVANIZED CHANNEL WITH PIPE CLAMP PER MANUFACTURER CONDUIT COOPER B-LINE DURA-BLOK SLEEPER (OR SIMILAR) AT 5'-0" O.C. MAXROOF DECK ROOF CONDUIT MOUNTING DETAIL (IF APPLICABLE) 3 4 2 3 1 4 2 1 2 3 4 CONDUIT (TYP) P1119 OR P2558 CLAMP EXISTING WALL/CEILING CONDUIT WALL MOUNT DETAIL (IF APPLICABLE) "UNISTRUT" P1000T. REQUIRED LENGTH BASED ON QUANTITY OF CONDUIT TO BE MOUNTED. INSTALL AT 5'-0" O.C. MAX. W/ FASTENER PER ATTACHMENT TABLE AT EACH END. 1 UNISTRUT WALL ATTACHMENT: WALL CONSTRUCTION TYPE FASTENER HOLLOW, AT STUD 3/8" DIA. x 2-1/2" EMBED LAG SCREW CONCRETE BLOCK (HOLLOW) 3/8" DIA. HILTI HY-270 (ESR-4143) WITH SCREEN, MINIMUM EMBEDMENT 2-3/8" CONCRETE (SOLID) 3/8" DIA. HILTI HY-200 (ESR-3963), MINIMUM EMBEDMENT 2-3/8" NOTES: 1. USE GALVANIZED OR STAINLESS STEEL HARDWARE FOR WALL MOUNT AND CONNECTION OF CHANNELS 2. GC SHALL USE NON-SHRINKING CAULK TO WEATHER SEAL ALL PENETRATIONS INTO OR THROUGH WALL CEC CEC CEC ELECTRICAL DETAILS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: E-2 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 2621 S Birch St - 101119515 & 20182981 7/24/2024 G TA VN NC SS VV VS VB PT GT GY GR GL GROUNDING NOTES: 1.IF MORE THAN 20' FROM EXISTING GROUND RING, INSTALL GROUND ROD (5/8" x 10' SS). ROD SPACING: 10' MIN. TOP OF ROD AND GROUND WIRE TO BE BELOW FROST LINE. 2.CONTRACTOR SHALL COORDINATE INCOMING SERVICES WITH LOCAL UTILITIES PRIOR TO TRENCHING. 3.ALL CONDUCTORS SHALL BE COPPER, 75 DEGREES C RATED, AND CONDUCTOR INSULATION BE THWN OR THHN. 4.ALL TERMINATION SHALL BE LISTED AND IDENTIFIED FOR USE WITH 75°C RATED CONDUCTORS OPERATING AT 75°C. 5.GROUND FAULT PROTECTION REQUIRED FOR UTILITY RECEPTACLES. 6.GENERATOR NEUTRAL SHALL NOT BE GROUNDED AT THE GENERATOR. REFER TO SINGLE LINE DETAIL, SHEET E-1. 7.EQUIPMENT LOCATED OUTSIDE OR EXPOSED TO MOISTURE SHALL BE NEMA 3R RATED. 8.CONTRACTOR SHALL USE SCHEDULE 80 PVC CONDUIT THROUGH CONCRETE AND ABOVE GROUND, UNLESS OTHERWISE NOTED. 9.ALL NEWLY INSTALLED EQUIPMENT SHALL BE RATED "AT 10K AIC" MINIMUM. HIGHER RATINGS SHALL BE REQUIRED WHERE AVAILABLE FAULT CURRENT EXCEEDS THIS VALUE. EXACT FAULT CURRENT AVAILABLE SHALL BE COORDINATED WITH LOCAL UTILITY BASED ON EXACT CONDITIONS (XFMR SIZE, PERCENT IMPEDANCE, LENGTH OF CONDUCTORS, ETC). GROUND ROD DETAILS CADWELD DETAILS GROUND ROD NOTES: 1.GROUND RODS MAY BE: - COPPER CLAD STEEL - SOLID COPPER 2.GROUND RODS SHALL HAVE A MAXIMUM SPACING TWICE THE LENGTH OF ROD 3.SEE RESISTIVITY REPORT FOR VERIFICATION AS AVAILABLE 4.A LARGER CONDUCTOR SHALL BE REQUIRED IN AREAS HIGHLY PRONE TO LIGHTNING AND/OR AREAS WITH HIGHLY ACIDIC SOIL 5.GROUND RODS INSTALLED WITHIN CLOSE PROXIMITY TO TOWER OR WHEN SOIL IS AT OR BELOW 2,000 OHM-CM, SHALL BE GALVANIZED TO PREVENT GALVANIC CORROSION OF TOWER, (SEE ANSI/TIA-EIA-222) 6.PROVIDE (1) GROUND LEAD TO EACH SIDE OF THE GENERATOR CADWELD GRADE #2 AWG BCW GROUND RING GROUND ROD 5 8"Ø x 10'-0" LONG MAX. CONTRACTOR SHALL NOT SUBMIT BIDS OR PERFORM CONSTRUCTION WORK ON THIS PROJECT WITHOUT ACCESS TO THE CURRENT COMPLETE SET OF DRAWINGS LISTED IN THE TITLE-SHEET INDEX. 30" OR 6" BELOW FROST LINE, WHICHEVER IS DEEPER. EXISTING EQUIPMENT SHELTER OR PAD TRANSFER SWITCH & CAM-LOCK BOX PROPOSED GENERATOR #2 AWG BARE TINNED GROUND WIRE TO EXISTING EQUIPMENT GROUND RING. GROUND GENERATOR PER MANUFACTURER'S RECOMMENDATIONS EXISTING GROUND WIRE, TYP. EXISTING BURIED EQUIPMENT GROUND RING (FIELD LOCATE) #2 AWG GROUNDED TO FENCE IF LESS THAN 6FT ELECTRICAL SYMBOLS LEGEND EXOTHERMIC WELD TYPE CONNECTION MECHANICAL TYPE CONNECTION NEW GROUNDING EXISTING GROUNDING TYPICAL GROUNDING DIAGRAM FENCE GROUNDING: 1.SEE FENCE & GATE DETAILS SHEET FOR ADDITIONAL GROUNDING (IF APPLICABLE) #2 AWG BARE TINNED BOND TO NEW GROUND ROD (IF NOT ADJACENT TO COMPOUND OR EQUIPMENT GROUND RING) (TYP.OF TWO) #2 AWG BARE TINNED BOND TO NEW GROUND ROD (IF NOT ADJACENT TO COMPOUND OR EQUIPMENT GROUND RING) ELECTRICAL DETAILS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: E-3 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 E-3 2621 S Birch St - 101119515 & 20182981 7/24/2024 3G 2.2 GENERAC 30KW GENERATOR SPECIFICATIONS * All measurements are approximate and for estimation purposes only. Specification characteristics may change without notice. Please contact a Generac Power Systems Industrial Dealer for detailed installation drawings. NOTE: IT IS RECOMMENDED THAT BATTERY BE WITHIN LEAK CONTAINMENT BOX OR TRAY SD030 |2.2L |30 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency SP E C S H E E T 1 of 6 Powering AheadCodes and Standards Not all codes and standards apply to all configurations. Contact factory for details. UL2200, UL508, UL489, UL142 CSA C22.2 BS5514 and DIN 6271 SAE J1349 NFPA 37, 70, 99, 110 NEC700, 701, 702, 708 ISO 3046, 7637, 8528, 9001 NEMA ICS10, MG1, 250, ICS6, AB1 ANSI C62.41 ® Standby Power Rating 30 kW, 38 kVA, 60 Hz Prime Power Rating* 27 kW, 34 kVA, 60 Hz *EPA Certified Prime ratings are not available in the US or its Territories For over 50 years, Generac has provided innovative design and superior manufacturing. Generac ensures superior quality by designing and manufacturing most of its generator components, including alternators, enclosures and base tanks, control systems and communications software. Generac gensets utilize a wide variety of options, configurations and arrangements, allowing us to meet the standby power needs of practically every application. Generac searched globally to ensure the most reliable engines power our generators. We choose only engines that have already been proven in heavy-duty industrial applications under adverse conditions. Generac is committed to ensuring our customers' service support continues after their generator purchase. CONTROL SYSTEM Digital H Control Panel- Dual 4x20 Display Program Functions .Programmable Crank Limiter .7-Day Programmable Exerciser .Special Applications Programmable Logic Controller .RS-232/485 Communications .All Phase Sensing Digital Voltage Regulator .2-Wire Start Capability .Date/Time Fault History (Event Log) .Isochronous Governor Control .Waterproof/Sealed Connectors .Audible Alarms and Shutdowns .Not in Auto (Flashing Light) .Auto/Off/Manual Switch .E-Stop (Red Mushroom-Type) .NFPA110 Level I and II (Programmable) .Customizable Alarms, Warnings, and Events .Modbus® Protocol .Predictive Maintenance Algorithm .Sealed Boards .Password Parameter Adjustment Protection .Single Point Ground .16 Channel Remote Trending .0.2 msec High Speed Remote Trending .Alarm Information Automatically Annunciated on the Display Full System Status Display .Power Output (kW) .Power Factor .kW Hours, Total, and Last Run .Real/Reactive/Apparent Power .All Phase AC Voltage .All Phase Currents .Oil Pressure .Coolant Temperature .Coolant Level .Engine Speed .Battery Voltage .Frequency Alarms and Warnings .Oil Pressure .Coolant Temperature .Coolant Level .Engine Overspeed .Battery Voltage .Alarms and Warnings Time and Date Stamped .Snap Shots of Key Operation Parameters During Alarms and Warnings .Alarms and Warnings Spelled Out (No Alarm Codes) ENGINE SYSTEM .Oil Drain Extension .Air Cleaner .Fan Guard .Stainless Steel Flexible Exhaust Connection .Factory Filled Oil and Coolant .Radiator Duct Adapter (Open Set Only) .Critical Silencer (Enclosed Unit Only) .Engine Coolant Heater Fuel System .Fuel Lockoff Solenoid .Primary Fuel Filter Cooling System .Closed Coolant Recovery System .UV/Ozone Resistant Hoses .Factory-Installed Radiator .Radiator Drain Extension .50/50 Ethylene Glycol Antifreeze Electrical System .Battery Charging Alternator .Battery Cables .Battery Tray .Rubber-Booted Engine Electrical Connections .Solenoid Activated Starter Motor ALTERNATOR SYSTEM .UL2200 GENprotect .Class H Insulation Material .2/3 Pitch .Skewed Stator .Brushless Excitation .Sealed Bearing .Rotor Dynamically Spin Balanced .Amortisseur Winding (3-Phase Only) .Full Load Capacity Alternator .Protective Thermal Switch GENERATOR SET .Internal Genset Vibration Isolation .Separation of Circuits - High/Low Voltage .Separation of Circuits - Multiple Breakers .Wrapped Exhaust Piping .Standard Factory Testing .2 Year Limited Warranty (Standby Rated Units) .1 Year Limited Warranty (Prime Rated Units) .Silencer Mounted in the Discharge Hood (Enclosed Unit Only) ENCLOSURE (If Selected) .Rust-Proof Fasteners with Nylon Washers to Protect Finish .High Performance Sound-Absorbing Material (Sound Attenuation Enclosures) .Gasketed Doors .Stamped Air-Intake Louvers .Upward Facing Discharge Hoods (Radiator and Exhaust) .Stainless Steel Lift Off Door Hinges .Stainless Steel Lockable Handles .RhinoCoat - Textured Polyester Powder Coat Paint FUEL TANKS (If Selected) .UL 142/ULC S601 .Double Wall .Normal and Emergency Vents .Sloped Top .Sloped Bottom .Factory Pressure Tested .Rupture Basin Alarm .Fuel Level .Check Valve In Supply and Return Lines .RhinoCoat- Textured Polyester Powder Coat Paint .Stainless Steel Hardware STANDARD FEATURES SP E C S H E E T 2 of 6 EMERGENCY STOP COMMON ALARM AUTO OFF MANL LEVEL 2 ACOUSTIC ENCLOSURE Run Time - Hours Usable Capacity - Gal (L) L x W x H - in (mm) Weight - lbs (kg) Enclosure Only Steel Aluminum No Tank -94.8 (2,407) x 38.0 (965) x 61.1 (1,551) 510 (232) 341 (155) 19 54 (204)94.8 (2,407) x 38.0 (965) x 74.1 (1,881) 47 132 (501)94.8 (2,407) x 38.0 (965) x 86.1 (2,186) 75 211 (799)94.8 (2,407) x 38.0 (965) x 98.1 (2,491) 107 300 (1,136)94.8 (2,407) x 38.0 (965) x 98.1 (2,491) Rust-Proof Fasteners with Nylon Washers to GENERAC INDUSTRIAL POWER SD030 |2.2L |30 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency GENERAC INDUSTRIAL POWER GENERATOR SPECIFICATIONS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: E-4.0 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 FOR INFORMATION ONLY 2621 S Birch St - 101119515 & 20182981 7/24/2024 GENERAC 30KW GENERATOR SPECIFICATIONS NOTE: IT IS RECOMMENDED THAT BATTERY BE WITHIN LEAK CONTAINMENT BOX OR TRAY 3G 2.2 LEFT SIDE VIEW REAR VIEW RIGHT-SIDE VIEW TOP VIEW STUB-UP AREA DETAIL VIEW (2X SCALE) HIGH VOLTAGE STUB-UP AREA LOW VOLTAGE STUB-UP AREA GENERATOR SPECIFICATIONS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: E-4.1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 FOR INFORMATION ONLY 2621 S Birch St - 101119515 & 20182981 7/24/2024 GENERAC GENERATOR SPECIFICATIONS 3G 2.2 4 3 2 1 4 3 1 A B A B 302 [11.9] 570 [22.4] 1140 [44.9] 1710 [67.3] 76 [3.0] TYP 736 [29.0] 914 [36.0] MOUNTING HOLES W/RISERS 126.6 [5.0] 225.2 [8.9] 240.2 [9.5] TYP 115.2[4.5] TYP 208.6 [8.2] 438.1 [17.2] 588.1 [23.2] TYP 1336 [52.6] 2349 [92.5]300 [11.8] (STUB UP) 49.6 [2] 777.2 [30.6] STUB UP 281 [11.0] TYP 738.1 [29] 2692 [106.0] 104.2 [4.1] 950 [37.4] 520.1 [20.5] 724 [28.5] 125.6 [4.9] 150.0 [5.9] 1921.0[75.6] 130.0 [5.1] 1736.3 [68.4]170.0 [6.7] 18 [0.7] TYP 839 [33.0] MOUNTING HOLES W/O RISERS 19 [0.7] TYP 348 [13.7] REF 309 [12.2] 196 [7.7] 876.1 [34.49] I/N TANK FITTING PROVIDING FUNCTION 1 3/8" NPT COUPLING FUEL SUPPLY 2 2" NPT WELD FLANGE FUEL FILL 3 MECH/ELEC. FUEL LEVEL 4 3/8" NPT COUPLING FUEL RETURN 5 2" NPT WELD FLANGE VENT 6 3" NPT WELD FLANGE INNER EMERGENCY VENT 7 1/2" NPT HALF COUPLING RUPTURE BASIN LEAK SENSOR 8 3" NPT WELD FLANGE OUTER TANK EMERGENCY VENT 9 3/8" NPT COUPLING 5 GALLON SPILL/FILL DRAIN 10 2" NPT WELD FLANGE 90% FUEL SWITCH 11 2" NPT WELD FLANGE RUPTURE BASIN ALARM TANK P/N 0L35190ST03 TOTAL CAPACITY 757 [200] USABLE CAPACITY 720 [190] EST. DRY WEIGHT 420 [924] TITLE INSTALL BASETANK A-GROUP EXTENDED 190G (USEABLE) / 200 G (TOTAL) ISSUE DATE:12/15/17 SIZE CAGE NO DWG NO 10000026896 REV B N/A A SCALE 0.050 WT-KG 958.184 SHEET 1 of 1 GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS. c GENERAC POWER SYSTEMS 2013 ELECTRONICALLY APPROVED INSIDE WINDCHILL DRAWING CREATED FROM PRO/ENGINEER 3D FILE. ECO MODIFICATION TO BE APPLIED TO SOLID MODEL ONLY. SH 1/1 REV A WINDCHILL VERSION A.3 CAPACITY SHOWN: LITER [GALLONS] WEIGHT SHOWN:KILOGRAMS[POUNDS] LENGTH SHOWN: MM [INCH] NOTE: UL 142 / ULC-S601 LISTED MOUNTING HOLES 17.5 [0.69] (8 PLACES BOTTOM) (10 PLACES TOP) OPTIONAL 90% ALARM 1 4 2 3 68 5 14 9 10 11 REMOVABLE STUB UP COVER PLATE 7 OPTIONAL TANK RISERS GENERATOR SPECIFICATIONS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: E-4.2 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 FOR INFORMATION ONLY 2621 S Birch St - 101119515 & 20182981 7/24/2024 GENERAC GENERATOR SPECIFICATIONS OVERFILL PREVENTION VALVE INSIDE TANK (FACTORY-INSTALLED) GENERAC 0J7671 TUBE CUT LENGTH UPPER TUBE CUT TO LENGTH 157±2 (ASSEMBLED LENGTH) FLOAT ASSEMBLY FUEL SPILL/FILL DRAIN OUTSIDE TANK (FACTORY-INSTALLED) GENERAC 0J7606A REMOTE 90% FUEL ALARM (FACTORY-INSTALLED) GENERAC OF2908$ LED YELLOW w/ HOLDER DECAL ALARM HORN RESET DECAL ALARM HORN TEST SWITCH, TOGGLE DPOT MOMENTARY ENCL NEMA 3R 6"H 4"W 4"D PIEZO BUZZER PANEL MNT DECAL 90% FUEL LEVEL ALARM 11 4 5 3 9 8 3 2 7 12 6 1 11 4 4 10 10 9 10 4 REVISION : CN-0019649-W DATE ; 9/4/18 10 EXPLODED VIEW : EV VENT EXT AGRP 2"3 ATT DRAWING NO. : 0K9817A (FIRST 6 DIGITS ONLY) IN THE SYSTEM FOR CORRECT MATERIAL AND COLOR. (FOR REFERENCE SEE GUIDELINE 0H7169). * CUSTOMER: WHEN ORDERING REPLACEMENT PARTS, ENTER BASE NUMBER * MANUFACTURING: FOR CORRECT MATERIAL AND COLOR REFER TO AS400 BOM. (1) SHEET METAL PARTS LISTED IN THE BOM TABLE ARE REPRESENTING CENERIC PARTS (NO COLOR). NOTES (UNLESS OTHERWISE SPECIFIED) NUT HEX FL WHIZ 3/8-162G06410112 VENT CAP EMERG 3"NPT2072989J11 PIPE NIPPLE 3"X72" SCH40 PNTBK40H145410 BOLT U 3/8-16 X 3.50" W/SADDLE20E42649 COUPLING FULL 2-11.5 BLACK1068640B8 NUT HEX M6-1.0 G8 CLEAR ZINC2G0498137 SCREW HWHT M6-1 X 30 W/MKS20C2454B6 VENT OEM 2"1G0211785 COUPLING PIPE 3 ZINC4100000166764 PIPE 2"VENT EXTENSION 72"LG20G30453 KIT, SADDLE AND BOLT 2 1/2"10C79472 BRACKET VENT EXT AGRP 2"3 ATT10G3036YST0R(1)1 DESCRIPTIONQTY.PART#ITEM GROUP HDRAWING #:0K9817A EXPLODED VIEW: EV VENT EXT AGRP 2"3 ATT EMERGENCY VENT PIPE ASSEMBLY GENERATOR SPECIFICATIONS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: E-4.3 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 FOR INFORMATION ONLY 2621 S Birch St - 101119515 & 20182981 7/24/2024 CONTACT 98.6 REF BUNA N COMPRESSION GASKET NYLON NUT 5/8-11 THD 15/16 FLATS #22AWG LEAD WIRES 610MM EXTENSION INSTALLATION NOTE: HAND TIGHTEN + ONE QUARTER TURN. LEAK DETECTION MUST BE INSTALLED IN THE NORMALLY OPEN (N.O.) POSITION AS SHOWN FOR IT TO FUNCTION CORRECTLY IN GENERAC'S UL TANK SECONDARY CONTAINMENT LEAK DETECTION APPLICATION. OVER TIGHTENING WILL RESULT IN DAMAGE TO THE LEAK DETECTOR AND IMPROPER OPERATION. SPEC: MATERIAL: NYLON VENDOR P/N AND VENDOR: 165900, GEMS SENSORS MOUNTING ATTITUDE: HORIZONTAL RECOMMENDED HOLE SIZE: Ø 0.875", 1/32"-5/32" THICK PANEL. OPERATING TEMPERATURE: -40°F TO 250°F MAX. OPERATION PRESSURE: 100 PSIG AT 70°F THIS SWITCH IS U.L. RECOGNIZED - FILE #E45168, CSA LISTED - 30200 CONTACT RATING: 0.17 AMP, 120 V, 60 Hz, RESISTIVE 0.08 AMP, 240 V, 60 Hz, RESISTIVE 20 VA PILOT DUTY DC ELEC. RATING: 0.3 AMP MAX @30 VDC GENERAC 096500B FUEL LEAK DETECTOR ALARM (FACTORY-INSTALLED) GENERAC GENERATOR SPECIFICATIONS GENERAC EMERGENCY VENT CAPS GENERATOR SPECIFICATIONS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: E-4.4 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 FOR INFORMATION ONLY 2621 S Birch St - 101119515 & 20182981 7/24/2024 G GENERAC ATS SPECIFICATIONS STEEL CONSTRUCTION =NEMA 3R ENCLOSURE WITH HINGED "PADLOCKING" DOORS = STAINLESS STEEL HARDWARE = CAMLOCK "QUICK CONNECT" CAPABILITY =OPERATIONAL STATUS VIEW VIA 6 INCH TOUCH SCREEN = TEST FUNCTION - FAST TEST & NORMAL TEST = UL1008 LISTED - FOR EMERGENCY SYSTEMS = EXTENDED WARRANTY = THREE-PHASE VOLTAGE CONFIGURATIONS Features Optional Features TTS Series Switches TAS200 200 Amps 600 VAC 200A Automatic Transfer Switch = The Generac TAS200 Automatic Transfer Switch Flexibility for multiple application installations Multiple generator support with 3 source panel improved user interface Camlock functionality for mobile generator sources Generac products are designed to the following standards: UL1008, UL508, UL50, CSA C22.2 No. 178 NEC 700, 701 and 702 NEMA 250 Codes and Standards Cabinet Specifications Dimensions 24"W x 12"D x 48"H Weight 210 lbs. Construction Single Chamber with Main Door Steel UL Type / NEMA 3R Rated Powder Coat Finish for Corrosion Resistance C-UL-US Listed - Automatic Transfer Switch Stainless Steel Hardware 3-Point Latching System with Pad-Lockable Handles Mounting Options Wall H-frame Installed Pre-wired alarm terminal strip Electrical Specifications Voltage/Phase/Amps 120/240 Single-Phase, 200A 120/208 3-Phase, 200A 120/240 3-Phase, 200A Breaker Eaton 200 amp Utility Breaker Eaton 200 amp Generator Breaker Maximum RMS Symmetrical Fault Current - Amps 25k AIC Rated Protective Device Continuous Rating (Max) Amp 200 Input to Generator 350MCM - #6 AWG Output to Site 350MCM - #6 AWG Generator Annunciator Connector Deutsch DTM04-12PA-L012 Alarm Terminal Board Generator Run Alarm Generator Fail - Shutdown Alarm Generator Fail - Non Shutdown Alarm Low Fuel Alarm Generator Theft Alarm AC Utility Fail Alarm Application and Engineering Data ® Designed with a 6 inch touch screen controller for GENERAC INDUSTRIAL POWER ATS SPECIFICATIONS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: E-5.0 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 FOR INFORMATION ONLY 2621 S Birch St - 101119515 & 20182981 7/24/2024 G CAM-LOCK BOX SPECIFICATIONS Camlock Component Camlock Component Shipped loose for multiple installation options Dimensions 9" W x 9.4" D x 24.25" H 200A Camlock Generator Connection Single-Phase: Black L1, Red L2, White-Neutral, Green-Ground 3-Phase: Black L1, Red L2, Blue L3, White-Neutral, Green-Ground Uses 4 CH E1016 Male Connectors Mating Connector - CH E1016 Female TTS Control Systems INDICATORS AND BUTTONS System Ready indicator Standby Operating indicator Utility Available indicator GEN/UTIL Switch Position indicator TVSS status Normal Test button Fast Test button Return to Normal button Reset button Exercising indicator DETAILS SCREEN System Settings: . System Voltage/Phases: - 120/240V single phase (standard) - 120/208V three phase (optional) - 120/240V three phase (optional) . Utility Fail Monitor: - Under Voltage: 75-95% of nominal voltage - Over Voltage: 105%-125% of nominal voltage - Pickup (hysteresis): fixed at 5 volts - Delay time: 0-60s . Utility Interrupt Delay: 0-60s . Return to Utility Timer: 1-30 minutes . Transfer: - In-phase, or - Time-Delay-Neutral at 0.0-10.0s in 1 second increments Engine Settings: . Engine Warm-up timer: 0-20 minutes . Generator Load Accept: - Time-Delay-Neutral at 0.0-10.0s in 1 sec increments - Voltage: 85-95% of nominal - Frequency: 85-95% of nominal . Engine Minimum Run Timer: 5-30 minutes . Engine Cooldown Timer: 0-20 minutes Exercise Settings: . Time of day . Day of week . Exercise: - Exercise with/without load - Exercise once every 1, 2, or 4 weeks. - Exercise time-of-day - Exercise day of week - Exercise duration: 15-30 minutes Screen Settings: . Brightness & Contrast button . Screen Calibration button . Startup/Clean screen Diagnostics: . Digital I/O bits status . Voltage A/D readings Mimic Diagram: . System Ready . Transfer switch position . Utility available . Standby available . Maintenance/Auto switch position . Generator source TS position . TVSS status GENERAC INDUSTRIAL POWER CAM-LOCK BOX SPECIFICATIONS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/01/24 ISSUED FOR CONSTRUCTION BM SHEET TITLE: SHEET NUMBER: E-5.1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 2621 SOUTH BIRCH STREET SANTA ANA, CA 92707 GENERATOR INSTALLATION PROJECT MAIN - DYER 10086996 CHECKED BY:JAD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/25 JURISDICTION USE: DATE SIGNED: 4/2/24 FOR INFORMATION ONLY 2621 S Birch St - 101119515 & 20182981 7/24/2024 GeoStructural ▪P.O. Box 2621, Boise, ID 83701 ▪ Office: (530) 539-4787 Page 1 Professional Engineers | Tower Technicians | Climbers | sUAS Mapping 10086996_Gen Slab Analysis_R0 240401 5508 Structural Analysis Report • New Concrete Slab• Site ID:10086996 Site Name::Main -Dyer Project:Generator Upgrade Prepared For:AT&T Structure Description:Concrete Slab & Anchorage Diesel Backup Generator Site Location:2621 S. Birch St. Santa Ana, CA 92707 Orange County 33.711743°, -117.869806° Design Codes:CBC 2022 ASCE 7-16 Date Signed: 4/2/2024 Revision 0 April 2, 2024 2621 S Birch St - 101119515 & 20182981 7/24/2024 AT&T | 10086996 |Main - Dyer - Concrete Slab Structural Analysis Page 2 GeoStructural, LLC | PO Box 2621 | Boise, ID 83701 | p:530.539.4787 1.0 Introduction GeoStructural has completed a structural analysis for the existing AT&T 10086996 communications site located in Orange County, CA. The scope of this structural analysis is limited to the following: 4'-0" x 10'-0" x 9" Reinforced Concrete Generator Slab w/ #5 Bars @ 12" O.C. Each Way. Generac Diesel Generator Equipment Anchorage. The existing communications structure/foundation and existing equipment platform(s)/shelter(s) are designed by others and beyond the scope of this analysis. 2.0 Analysis & Design Criteria This analysis is pursuant to the following design criteria: CBC 2022 – California Building Code. ASCE 7-16 – Minimum Design Loads and Associated Criteria for Buildings and Other Structures. AISC – Steel Construction Manual. ACI 318-19 – Building Code Requirements for Structural Concrete. Gravity Design Loading: Generac 30kW Generator w/ L2A Enclosure = 2,182lbs 200gal Fuel Tank (Dry) = 924 lbs Diesel Fuel (100% Fill + 35% Contain) = 7.3 lb/gal(270gal) = 1,971 lbs WET Total Assembly Weight = 5.077 kips ; DRY Total Assembly Weight = 3.106 kips Wind Design Loading: Design Wind w/o ice = 95 mph [3-sec gust Ultimate ASCE Figure 26.5-1B] Exposure Category C Topographic Category 1 Risk Category II Seismic Design Loading: Site Class D Importance Factor, Ip = 1.0 Ss = 1.279, S1 = 0.458, SDS = 1.023 All data required to complete our structural analysis was furnished by our client. GeoStructural has not conducted an independent study to verify existing site conditions and the results of this analysis are based solely on the information provided. 2621 S Birch St - 101119515 & 20182981 7/24/2024 AT&T | 10086996 |Main - Dyer - Concrete Slab Structural Analysis Page 3 GeoStructural, LLC | PO Box 2621 | Boise, ID 83701 | p:530.539.4787 3.0 Load Generation & Material Strength Table 3.1 – Wind Design Loading Wind Load – Velocity Pressure ASCE 7-16, §29.3 qz = 0.00256 Kz Kzt Kd V2 Eq. 29.3-1 Kz = 0.85 Table 29.3-1 Kzt = 1.00 § 26.8.2 Kd = 0.90 Table 26.6-1 V = 95 mph Figure 26.5 qz = 0.00256*0.85*1.00*0.90*(95^2)/1000 = 0.0177 ksf Eq. 29.3-1 Wind Load – Other Structures (Tanks & Similar Structures) ASCE 7-16, §29.5 F = qzGCfAf Eq. 29.5-1 G = 0.85 § 26.9 Cf = 1.32 Figure 29.5-1 Af = 58.6 ft2 Worst Case; 22.4 ft2 Transverse (Side) Generac FN = 0.0177*0.85*1.32*58.6 = 1.16 kip; FT = 0.0177*0.85*1.32*22.4 = 0.44 kip Eq. 29.5-1 Table 3.2 – Seismic Design Loading – 100% Fill + 35% Seismic Load – Non-Structural Components ASCE 7-16, Chapter 13 Fp = 0.4apSDSWp{(1+2(z/h)) / (Rp/Ip)} Eq. 13.3-1 Fp ≤ 1.6SDSIpWp Eq. 13.3-2 Fp > 0.3SDSIpWp Eq. 13.3-3 Reversible Vert Force, Ev = 0.2SDSWp = 0.2*1.023*5.077 = 1.04 kip § 13.3.1 ap = 1.0 Table 13.6-1 SDS = (2/3)SMS = 1.023 ; SD1 = (2/3)SM1 Eq. 11.4-3 & 4 Ss; S1 USGS Reference Fa ; Fv Tables 11.4-1 & 2 SMS = FaSs ; SM1 = FvS1 Eq. 11.4-1 & 2 Wp = 5.077 kip (Wet Weight) From Section 2.0 Above z = 0 ft (Anchorage Height of Generator Tank to Slab) Slab-On-Grade h = 7.50 ft (Overall Height of Generator with Tank Assembly) Slab-On-Grade Rp = 2.5 Table 13.6-1 Importance Factor, Ip = 1.0 § 11.5.1 & 13.1.3 ρ = 1.0 (Exception from ρ = 1.3, Non-Structural Components) § 12.3.4.2 & § 13.3.1 Fp = 0.4apSDSWp{(1+2(z/h)) / (Rp/Ip)} = 0.4*1.0*1.023*5.077*(1+2*(0/7.50))/(2.5/1.0) = 0.83 kip Eq. 13.3-1 Fp ≤ 1.6SDSIpWp = 1.6*1.023*1.0*5.077 = 8.31 kip Eq. 13.3-2 Fp > 0.3SDSIpWp = 0.3*1.023*1.0*5.077 = 1.56 kip Eq. 13.3-3 2621 S Birch St - 101119515 & 20182981 7/24/2024 AT&T | 10086996 |Main - Dyer - Concrete Slab Structural Analysis Page 4 GeoStructural, LLC | PO Box 2621 | Boise, ID 83701 | p:530.539.4787 Table 3.3 – Seismic Overstrength Anchorage Loading (ACI 318-19 § 17.2.3.4.3(d) & 17.2.3.5.3(c)) Seismic Load – Non-Structural Components ASCE 7-16, Chapter 13 (0.9-0.2(SDS))D + Ω0QE Eq. 12.4.3.2 (7) Ω0 = 2.0 Table 13.6-1 Vertical C.O.G. = ((2.182*4.88)+(2.895*1.17))/5.077 = 2.77 ft Net OTM = (1.56*2.77*2.0)-(((0.9-(0.2*1.023))*5.077)*1.5) = 3.34 k-ft Omega AB Tension = (3.3/(33/12)/(8/2))+((1.04*2.0)/8) = 0.56 kip Net Shear = (1.56*2.0)-(((0.9-(0.2*1.023))* 5.077)*0.3) = 2.06 kip Omega AB Shear = 2.06/(8/2) = 0.51 kip (Assume 1/2 AB engage) Table 3.4 – Structural Component Material Strengths Structural Component Nominal Strength/Material1 Mechanical Anchors Simpson Strong Bolt 2 Stainless Steel Expansion Anchors (ICC-ES ESR-3037) Concrete Slab fc’ = 2500 psi Steel Reinforcing Fy = 60 ksi Allowable Soil Capacities Bearing = 1,000 psf Passive Sliding = 100 psf/ft μ = 0.3 1.Strengths listed were utilized for this analysis and are based upon ASTM, AISC, RCSC, MSJC, AWS and ACI preferred specification values. Values and materials are consistent with industry standards. Material strengths were taken from original design documents, geotechnical reports, etc. when available. Table 3.5 – Analysis Parameter Design Checks Parameter Site Specific (Demand)1 Result2 Wind Base Shear 1.16 Adequate Seismic Base Shear 1.56 Anchor Tension 0.56 Anchor Shear 0.51 1.The analysis (allowable) values listed for each parameter are the minimum values required to safely transmit the imparted loading through the foundation and anchorage to the surrounding soil without creating an unstable condition. The allowable values are based on the minimum presumptive values shown in Table 3.4 above. 2.Since the site-specific individual demand parameters are less than or equal to the maximum allowable values the foundation and anchorage design is deemed adequate to support the loading. 2621 S Birch St - 101119515 & 20182981 7/24/2024 AT&T | 10086996 |Main - Dyer - Concrete Slab Structural Analysis Page 5 GeoStructural, LLC | PO Box 2621 | Boise, ID 83701 | p:530.539.4787 4.0 Conclusion & Recommendations AT&T’s proposed reinforced concrete slab-on-grade and generator mechanical anchorage will satisfy the requirements of the applicable design codes and have sufficient capacity to support the proposed backup diesel generator loading considered in this analysis. Reinforced Concrete Generator Slab: o 4'-0" x 10'-0" x 9" Reinforced Concrete Generator Slab w/ #5 Bars @ 12" O.C. Each Way. Generac Diesel Generator Equipment Anchorage: o (8) 5/8”Ø x 5-1/8” Embed Simpson Strong Bolt 2 stainless steel expansion anchors (ICC-ES ESR-3037 report). Analysis Notes & Assumptions: All data required to complete our structural analysis was furnished by our client. GeoStructural has not conducted a site visit or independent study to verify existing conditions and the results of this analysis are based solely on the information provided. Proposed generator slab and anchorage shall be installed in accordance with any recommendations given in GeoStructural’s approved Construction Drawings. If any of the existing or proposed conditions reported in this analysis are not properly represented, please contact our office immediately to request an amended report. We appreciate the opportunity to provide our structural engineering services to you. If you have any questions regarding the content of this structural analysis report, please don’t hesitate to contact us. Prepared by:Reviewed and Approved by: Jesse Drennen, PE Don George, PE 208.761.7986 208.602.6569 jesse.drennen@geostructural.com don.george@geostructural.com 2621 S Birch St - 101119515 & 20182981 7/24/2024 AT&T | 10086996 |Main - Dyer - Concrete Slab Structural Analysis Page 6 GeoStructural, LLC | PO Box 2621 | Boise, ID 83701 | p:530.539.4787 5.0 Attachments, Calculations & Software Output This page intentionally left blank. 2621 S Birch St - 101119515 & 20182981 7/24/2024 ASCE Hazards Report Address: No Address at This Location Standard:ASCE/SEI 7-16 Latitude:33.711743 Risk Category:II Longitude:-117.869806 Soil Class:D - Default (see Section 11.4.3) Elevation:46.41951061272088 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Mon Apr 01 2024 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 5https://ascehazardtool.org/Mon Apr 01 2024 2621 S Birch St - 101119515 & 20182981 7/24/2024 SS : 1.279 S1 : 0.458 F a : 1.2 F v : N/A SMS : 1.535 SM1 : N/A SDS : 1.023 SD1 : N/A T L : 8 PGA : 0.543 PGA M : 0.652 F PGA : 1.2 Ie : 1 C v : 1.356 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Mon Apr 01 2024 Page 2 of 5https://ascehazardtool.org/Mon Apr 01 2024 2621 S Birch St - 101119515 & 20182981 7/24/2024 Ice Results: Data Source: Date Accessed: Ice Thickness: 0 in. Concurrent Temperature: 25 F Gust Speed 30 mph Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8 Mon Apr 01 2024 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Page 3 of 5https://ascehazardtool.org/Mon Apr 01 2024 2621 S Birch St - 101119515 & 20182981 7/24/2024 Flood Results: Data Source: Date Accessed: FIRM Panel: Insurance Study Note: Flood Zone Categorization: X (unshaded) Base Flood Elevation: FEMA National Flood Hazard Layer - Effective Flood Hazard Layer for US, where modernized (https://msc.fema.gov/portal/search) Mon Apr 01 2024 If available, download FIRM panel here Download FEMA Flood Insurance Study for this area here Page 4 of 5https://ascehazardtool.org/Mon Apr 01 2024 2621 S Birch St - 101119515 & 20182981 7/24/2024 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 5 of 5https://ascehazardtool.org/Mon Apr 01 2024 2621 S Birch St - 101119515 & 20182981 7/24/2024 General Footing LIC# : KW-06015027, Build:20.23.12.07 GeoStructural, LLC (c) ENERCALC INC 1983-2023 DESCRIPTION:Generator Reinforced Concrete Slab On Grade - Strength and Stability Analysis GeoStructural LLC Jesse Drennen, PE Project File: 3 GEN calcs MERGE.ec6 Project Title:AT&T Generator Upgrade Project Engineer:Jesse Drennen, PE Project ID: Project Descr:Standby Generator on Concrete Slab Code References Calculations per ACI 318-19, IBC 2021, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Material Properties Soil Design Values 1.0 Analysis Settings 100.0 ksi No ksfAllowable Soil Bearing = = 2.50 60.0 2,850.0 150.0 =0.30Flexure=0.90 Shear = ValuesM 0.00180 0.50 Soil Passive Resistance (for Sliding) 1.0 = Increases based on footing plan dimension Add Pedestal Wt for Soil Pressure No: Use Pedestal wt for stability, mom & shear No: Allowable pressure increase per foot of depth =ksfwhen max. length or width is greater than =ft : = Add Ftg Wt for Soil Pressure Yes Yes:Use ftg wt for stability, moments & shears when footing base is below ft pcf Increase Bearing By Footing Weight =pcf Min. Overturning Safety Factor = : 1 Increases based on footing Depth0.750 = Soil/Concrete Friction Coeff. Ec : Concrete Elastic Modulus = =Footing base depth below soil surface ft =Allow press. increase per foot of depth ksf = : 11.0Min. Sliding Safety Factor = = Concrete Density = Min Allow % Temp Reinf. ksif'c : Concrete 28 day strength fy : Rebar Yield ksi Min Steel % Bending Reinf. Soil Density =110.0 pcf # Dimensions Width parallel to X-X Axis 4.0 ft Length parallel to Z-Z Axis = 10.0 ft =Pedestal dimensions... px : parallel to X-X Axis 35.0 in pz : parallel to Z-Z Axis 106.0 in Height == 1.0 in Footing Thickness = 9.0 in= Rebar Centerline to Edge of Concrete... =inat Bottom of footing 5.0 Reinforcing # Bars parallel to X-X Axis Reinforcing Bar Size = 5 Number of Bars = 10.0 Bars parallel to Z-Z Axis Reinforcing Bar Size =5 Number of Bars =5.0 Bandwidth Distribution Check (ACI 15.4.4.2) Direction Requiring Closer Separation Bars along X-X Axis # Bars required within zone 57.1 % # Bars required on each side of zone 42.9 % Applied Loads 5.077 -1.040 D Lr ksf L S P : Column Load OB : Overburden = k W E M-zz V-x = =k1.160 1.560 V-z k-0.440 -1.560 4.360 M-xx = k-ft= k-ft 4.320 1.670 4.320 H = 2621 S Birch St - 101119515 & 20182981 7/24/2024 General Footing LIC# : KW-06015027, Build:20.23.12.07 GeoStructural, LLC (c) ENERCALC INC 1983-2023 DESCRIPTION:Generator Reinforced Concrete Slab On Grade - Strength and Stability Analysis GeoStructural LLC Jesse Drennen, PE Project File: 3 GEN calcs MERGE.ec6 Project Title:AT&T Generator Upgrade Project Engineer:Jesse Drennen, PE Project ID: Project Descr:Standby Generator on Concrete Slab PASS 1.493 Sliding - X-X 1.092 k 1.630 k +0.60D+0.70E PASS 1.424 Sliding - Z-Z 1.092 k 1.555 k +0.60D+0.70E DESIGN SUMMARY Design OK Governing Load CombinationMin. Ratio Item Applied Capacity PASS 0.3673 Soil Bearing 0.3673 ksf 1.0 ksf +D+0.70E about Z-Z axis PASS 4.448 Overturning - X-X 6.664 k-ft 29.641 k-ft +0.60D+0.70E PASS 2.132 Overturning - Z-Z 5.390 k-ft 11.492 k-ft +0.60D+0.70E PASS 7.893 Uplift -0.7280 k 5.746 k +0.60D+0.70E PASS 0.009940 Z Flexure (+X)0.05041 k-ft/ft 5.071 k-ft/ft +1.405D+E PASS 0.01144 Z Flexure (-X)0.05803 k-ft/ft 5.071 k-ft/ft +1.405D-E PASS 0.005386 X Flexure (+Z)0.03329 k-ft/ft 6.180 k-ft/ft +1.405D+E PASS 0.006816 X Flexure (-Z)0.04213 k-ft/ft 6.180 k-ft/ft +1.405D-E PASS 0.03312 1-way Shear (+X)1.469 psi 44.342 psi +1.405D+E PASS 0.03801 1-way Shear (-X)1.685 psi 44.342 psi +1.405D-E PASS 0.01617 1-way Shear (+Z)1.226 psi 75.824 psi +1.405D+E PASS 0.02046 1-way Shear (-Z)1.551 psi 75.824 psi +1.405D-E PASS 0.01770 2-way Punching 1.684 psi 95.134 psi +1.405D-E Detailed Results Rotation Axis &ZeccXecc Actual Soil Bearing Stress @ Location Actual / Allow Soil Bearing (in)Gross Allowable Bottom, -Z Top, +Z Left, -X Right, +X RatioLoad Combination... X-X, D Only 1.0 n/a0.2394 0.2394 n/a 0.2390.0n/a X-X, +D+0.60W 1.0 n/a0.2278 0.2510 n/a 0.2510.9798n/a X-X, +0.60D+0.60W 1.0 n/a0.1320 0.1553 n/a 0.1551.633n/a X-X, +D+0.70E 1.0 n/a0.1898 0.2526 n/a 0.2532.867n/a X-X, +0.60D+0.70E 1.0 n/a0.09406 0.1568 n/a 0.1575.055n/a Z-Z, D Only 1.0 0.2394n/a n/a 0.2394 0.239n/a0.0 Z-Z, +D+0.60W 1.0 0.1208n/a n/a 0.3581 0.358n/a4.005 Z-Z, +0.60D+0.60W 1.0 0.0250n/a n/a 0.2623 0.262n/a6.674 Z-Z, +D+0.70E 1.0 0.07518n/a n/a 0.3673 0.367n/a5.335 Z-Z, +0.60D+0.70E 1.0 0.0n/a n/a 0.2736 0.274n/a9.407 Rotation Axis & Overturning Stability Load Combination...StatusOverturning Moment Resisting Moment Stability Ratio X-X, D Only None 0.0 k-ft Infinity OK X-X, +D+0.60W 1.002 k-ft 48.105 k-ft 48.009 OK X-X, +0.60D+0.60W 1.002 k-ft 28.951 k-ft 28.893 OK X-X, +D+0.70E 6.664 k-ft 48.795 k-ft 7.322 OK X-X, +0.60D+0.70E 6.664 k-ft 29.641 k-ft 4.448 OK Z-Z, D Only None 0.0 k-ft Infinity OK Z-Z, +D+0.60W 3.196 k-ft 19.154 k-ft 5.993 OK Z-Z, +0.60D+0.60W 3.196 k-ft 11.492 k-ft 3.596 OK Z-Z, +D+0.70E 5.390 k-ft 19.154 k-ft 3.554 OK Z-Z, +0.60D+0.70E 5.390 k-ft 11.492 k-ft 2.132 OK Force Application Axis Sliding Stability All units k Load Combination...StatusSliding Force Resisting Force Stability Ratio X-X, D Only 0.0 k 2.998 k No Sliding OK X-X, +D+0.60W 0.6960 k 2.998 k 4.308 OK X-X, +0.60D+0.60W 0.6960 k 1.849 k 2.656 OK X-X, +D+0.70E 1.092 k 2.780 k 2.546 OK X-X, +0.60D+0.70E 1.092 k 1.630 k 1.493 OK Z-Z, D Only 0.0 k 2.923 k No Sliding OK Z-Z, +D+0.60W -0.2640 k 2.923 k 11.072 OK 2621 S Birch St - 101119515 & 20182981 7/24/2024 General Footing LIC# : KW-06015027, Build:20.23.12.07 GeoStructural, LLC (c) ENERCALC INC 1983-2023 DESCRIPTION:Generator Reinforced Concrete Slab On Grade - Strength and Stability Analysis GeoStructural LLC Jesse Drennen, PE Project File: 3 GEN calcs MERGE.ec6 Project Title:AT&T Generator Upgrade Project Engineer:Jesse Drennen, PE Project ID: Project Descr:Standby Generator on Concrete Slab Force Application Axis Sliding Stability All units k Load Combination...StatusSliding Force Resisting Force Stability Ratio Z-Z, +0.60D+0.60W -0.2640 k 1.774 k 6.719 OK Z-Z, +D+0.70E -1.092 k 2.705 k 2.477 OK Z-Z, +0.60D+0.70E -1.092 k 1.555 k 1.424 OK Flexure Axis & Load Combination in^2 in^2 in^2 k-ft As Req'd Footing Flexure Tension k-ft Actual As StatusMuSide Surface Gvrn. As Phi*Mn X-X, +1.40D 0.03021 +Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +1.40D 0.03021 -Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +1.20D+W 0.02909 +Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +1.20D+W 0.02270 -Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +1.20D-W 0.02270 +Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +1.20D-W 0.02909 -Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +0.90D+W 0.02261 +Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +0.90D+W 0.01623 -Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +0.90D-W 0.01623 +Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +0.90D-W 0.02261 -Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +1.405D+E 0.03329 +Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +1.405D+E 0.01849 -Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +1.405D-E 0.02733 +Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +1.405D-E 0.04213 -Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +0.6954D+E 0.01798 +Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +0.6954D+E 0.003187 -Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +0.6954D-E 0.01203 +Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK X-X, +0.6954D-E 0.02682 -Z Bottom 0.1944 ACI 7.6.1.1 0.3875 6.180 OK Z-Z, +1.40D 0.02604 -X Bottom 0.1944 ACI 7.6.1.1 0.310 5.071 OK Z-Z, +1.40D 0.02604 +X Bottom 0.1944 ACI 7.6.1.1 0.310 5.071 OK Z-Z, +1.20D+W 0.004308 -X Top 0.1944 ACI 7.6.1.1 0.310 7.861 OK Z-Z, +1.20D+W 0.04895 +X Bottom 0.1944 ACI 7.6.1.1 0.310 5.071 OK Z-Z, +1.20D-W 0.04895 -X Bottom 0.1944 ACI 7.6.1.1 0.310 5.071 OK Z-Z, +1.20D-W 0.004308 +X Top 0.1944 ACI 7.6.1.1 0.310 7.861 OK Z-Z, +0.90D+W 0.009888 -X Top 0.1944 ACI 7.6.1.1 0.310 7.861 OK Z-Z, +0.90D+W 0.04337 +X Bottom 0.1944 ACI 7.6.1.1 0.310 5.071 OK Z-Z, +0.90D-W 0.04337 -X Bottom 0.1944 ACI 7.6.1.1 0.310 5.071 OK Z-Z, +0.90D-W 0.009888 +X Top 0.1944 ACI 7.6.1.1 0.310 7.861 OK Z-Z, +1.405D+E 0.005779 -X Top 0.1944 ACI 7.6.1.1 0.310 7.861 OK Z-Z, +1.405D+E 0.05041 +X Bottom 0.1944 ACI 7.6.1.1 0.310 5.071 OK Z-Z, +1.405D-E 0.05803 -X Bottom 0.1944 ACI 7.6.1.1 0.310 5.071 OK Z-Z, +1.405D-E 0.001841 +X Bottom 0.1944 ACI 7.6.1.1 0.310 5.071 OK Z-Z, +0.6954D+E 0.01146 -X Top 0.1944 ACI 7.6.1.1 0.310 7.861 OK Z-Z, +0.6954D+E 0.04013 +X Bottom 0.1944 ACI 7.6.1.1 0.310 5.071 OK Z-Z, +0.6954D-E 0.04495 -X Bottom 0.1944 ACI 7.6.1.1 0.310 5.071 OK Z-Z, +0.6954D-E 0.01070 +X Top 0.1944 ACI 7.6.1.1 0.310 7.861 OK One Way Shear X Vu @ +XLoad Combination...Vu @ -X Vu:Max Vu / Phi*VnPhi Vn Status +1.40D 0.74 0.74 0.74 44.34 0.02psipsipsipsi OK +1.20D+W 0.16 1.43 1.43 44.34 0.03psipsipsipsi OK +1.20D-W 1.43 0.16 1.43 44.34 0.03psipsipsipsi OK +0.90D+W 0.31 1.27 1.27 44.34 0.03psipsipsipsi OK +0.90D-W 1.27 0.31 1.27 44.34 0.03psipsipsipsi OK +1.405D+E 0.20 1.47 1.47 44.34 0.03psipsipsipsi OK +1.405D-E 1.69 0.02 1.69 44.34 0.04psipsipsipsi OK +0.6954D+E 0.33 1.18 1.18 44.34 0.03psipsipsipsi OK +0.6954D-E 1.31 0.33 1.31 44.34 0.03psipsipsipsi OK One Way Shear Z Load Combination...Vu @ -Z Vu @ +Z Vu:Max Vu / Phi*VnPhi Vn Status +1.40D 1.11 1.11 1.11 75.82 0.01psipsipsipsi OK +1.20D+W 0.83 1.07 1.07 75.82 0.01psipsipsipsi OK +1.20D-W 1.07 0.83 1.07 75.82 0.01psipsipsipsi OK +0.90D+W 0.60 0.83 0.83 75.82 0.01psipsipsipsi OK 2621 S Birch St - 101119515 & 20182981 7/24/2024 General Footing LIC# : KW-06015027, Build:20.23.12.07 GeoStructural, LLC (c) ENERCALC INC 1983-2023 DESCRIPTION:Generator Reinforced Concrete Slab On Grade - Strength and Stability Analysis GeoStructural LLC Jesse Drennen, PE Project File: 3 GEN calcs MERGE.ec6 Project Title:AT&T Generator Upgrade Project Engineer:Jesse Drennen, PE Project ID: Project Descr:Standby Generator on Concrete Slab One Way Shear Z Load Combination...Vu @ -Z Vu @ +Z Vu:Max Vu / Phi*VnPhi Vn Status +0.90D-W 0.83 0.60 0.83 75.82 0.01psipsipsipsi OK +1.405D+E 0.68 1.23 1.23 75.82 0.02psipsipsipsi OK +1.405D-E 1.55 1.00 1.55 75.82 0.02psipsipsipsi OK +0.6954D+E 0.11 0.66 0.66 75.82 0.01psipsipsipsi OK +0.6954D-E 0.99 0.44 0.99 75.82 0.01psipsipsipsi OK Vu / Phi*Vn Two-Way "Punching" Shear All units k StatusVuPhi*VnLoad Combination... +1.40D 1.46 95.13 0.01539 OKpsipsi +1.20D+W 1.26 95.13 0.0132 OKpsipsi +1.20D-W 1.26 95.13 0.0132 OKpsipsi +0.90D+W 0.94 104.41 0.009017 OKpsipsi +0.90D-W 0.94 95.13 0.009896 OKpsipsi +1.405D+E 1.26 104.41 0.01202 OKpsipsi +1.405D-E 1.68 95.13 0.0177 OKpsipsi +0.6954D+E 0.61 95.13 0.006362 OKpsipsi +0.6954D-E 0.95 95.13 0.01002 OKpsipsi 2621 S Birch St - 101119515 & 20182981 7/24/2024 Beam on Elastic Foundation LIC# : KW-06015027, Build:20.23.12.07 GeoStructural, LLC (c) ENERCALC INC 1983-2023 DESCRIPTION:Slab On Grade - "Beam" on Soil Spring Design GeoStructural LLC Jesse Drennen, PE Project File: 3 GEN calcs MERGE.ec6 Project Title:AT&T Generator Upgrade Project Engineer:Jesse Drennen, PE Project ID: Project Descr:Standby Generator on Concrete Slab CODE REFERENCES Calculations per ACI 318-19, IBC 2021, ASCE 7-16 Load Combinations Used : ASCE 7-16 Material Properties 2.50 7.50 150.0 Elastic Modulus 2,850.0 ksi Soil Subgrade Modulus =47.0 psi / (inch deflection) 11.0Lt Wt FactorO = =60.0 29,000.0 40.0 29,000.0 3 Beam is supported on an elastic foundation, 2 =0.90 0.750 f'c ksi fy - Main Rebar ksi Density 1/2 = fr = f'c *375.0 pcf E - Main Rebar ksi psi = Fy - Stirrups ksi == = E - Stirrups ksi E 0.850 == = Shear : Stirrup Bar Size # Number of Resisting Legs Per Stirrup Phi Values Flexure : \ # I Load Combination :ASCE 7-16 .Cross Section & Reinforcing Details Rectangular Section, Width = 48.0 in, Height = 9.0 in Span #1 Reinforcing.... 5-#5 at 4.0 in from Top, from 0.0 to 10.0 ft in this span .Service loads entered. Load Factors will be applied for calculations.Applied Loads Beam self weight calculated and added to loads Load for Span Number 1 Moment : W = 1.670, E = 4.320 k-ft, Location = 5.0 ft from left end of this span Point Load : D = 5.077 k @ 5.0 ft Point Load : E = 1.040 k @ 5.0 ft .Design OKDESIGN SUMMARY Maximum Bending Stress Ratio =0.460 : 1 Load Combination +1.405D+E Span # where maximum occurs Span # 1 Maximum Soil Pressure =0.288 ksf at 6.33 ft LdComb: +D+0.70E Allowable Soil Pressure =OK1.0 ksf Location of maximum on span 5.059 ft Mn * Phi : Allowable 24.720 k-ft Typical SectionSection used for this span Mu : Applied 11.377 k-ft Maximum Deflection Max Downward L+Lr+S Deflection 0.000 in Max Upward L+Lr+S Deflection 0.000 in Max Downward Total Deflection 0.042 in Max Upward Total Deflection 0.021 in .Shear Stirrup Requirements Entire Beam Span Length : Vu < PhiVc/2, Req'd Vs = Not Reqd, use stirrups spaced at 0.000 in .Maximum Forces & Stresses for Load Combinations Span # Bending Stress Results ( k-ft )Location (ft)Load Combination Mu : Max Stress RatioSegment Length Phi*Mnxin Span MAXimum Bending Envelope Span # 1 1 5.059 11.38 24.72 0.46 +1.40D 2621 S Birch St - 101119515 & 20182981 7/24/2024 Beam on Elastic Foundation LIC# : KW-06015027, Build:20.23.12.07 GeoStructural, LLC (c) ENERCALC INC 1983-2023 DESCRIPTION:Slab On Grade - "Beam" on Soil Spring Design GeoStructural LLC Jesse Drennen, PE Project File: 3 GEN calcs MERGE.ec6 Project Title:AT&T Generator Upgrade Project Engineer:Jesse Drennen, PE Project ID: Project Descr:Standby Generator on Concrete Slab Span # Bending Stress Results ( k-ft )Location (ft)Load Combination Mu : Max Stress RatioSegment Length Phi*Mnxin Span Span # 1 1 4.941 8.05 24.72 0.33 +1.20D+W Span # 1 1 5.059 7.72 24.72 0.31 +1.20D-W Span # 1 1 4.941 7.72 24.72 0.31 +0.90D+W Span # 1 1 5.059 6.00 24.72 0.24 +0.90D-W Span # 1 1 4.941 6.00 24.72 0.24 +1.405D+E Span # 1 1 5.059 11.38 24.72 0.46 +1.405D-E Span # 1 1 4.941 9.02 24.72 0.36 +0.6954D+E Span # 1 1 5.059 7.30 24.72 0.30 +0.6954D-E Span # 1 1 4.941 4.94 24.72 0.20 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections - Unfactored Loads Span 1 1 0.0425 6.333 0.0000 0.000 .Detailed Shear Information Load Combination Vu (k)Span Distance 'd'Comment Phi*Vs Req'd d*Vu/MuMu (ft)(k)(in)Actual Suggest(k-ft)Number (k) Spacing (in) Design Phi*Vc +1.405D-E 1 0.00 5.00 0.07 0.07 0.00 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 0.12 5.00 0.15 0.15 0.00 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 0.24 5.00 0.24 0.24 0.02 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 0.35 5.00 0.32 0.32 0.04 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 0.47 5.00 0.41 0.41 0.08 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 0.59 5.00 0.49 0.49 0.12 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 0.71 5.00 0.58 0.58 0.18 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 0.82 5.00 0.66 0.66 0.24 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 0.94 5.00 0.75 0.75 0.32 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 1.06 5.00 0.84 0.84 0.40 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 1.18 5.00 0.92 0.92 0.50 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 1.29 5.00 1.01 1.01 0.60 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 1.41 5.00 1.10 1.10 0.72 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 1.53 5.00 1.18 1.18 0.85 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 1.65 5.00 1.27 1.27 0.98 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 1.76 5.00 1.36 1.36 1.13 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 1.88 5.00 1.45 1.45 1.28 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 2.00 5.00 1.53 1.53 1.45 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 2.12 5.00 1.62 1.62 1.63 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 2.24 5.00 1.71 1.71 1.82 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 2.35 5.00 1.80 1.80 2.02 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 2.47 5.00 1.89 1.89 2.22 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 2.59 5.00 1.98 1.98 2.44 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 2.71 5.00 2.07 2.07 2.67 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 2.82 5.00 2.16 2.16 2.91 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 2.94 5.00 2.25 2.25 3.16 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 3.06 5.00 2.34 2.34 3.42 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 3.18 5.00 2.43 2.43 3.70 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 3.29 5.00 2.51 2.51 3.98 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 3.41 5.00 2.60 2.60 4.27 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 3.53 5.00 2.69 2.69 4.57 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 3.65 5.00 2.78 2.78 4.89 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 3.76 5.00 2.87 2.87 5.21 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 3.88 5.00 2.96 2.96 5.55 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 4.00 5.00 3.05 3.05 5.89 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 4.12 5.00 3.13 3.13 6.25 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 4.24 5.00 3.22 3.22 6.61 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 4.35 5.00 3.31 3.31 6.99 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 4.47 5.00 3.40 3.40 7.38 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 4.59 5.00 3.48 3.48 7.77 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 4.71 5.00 3.57 3.57 8.18 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 4.82 5.00 3.65 3.65 8.59 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D-E 1 4.94 5.00 3.73 3.73 9.02 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 5.06 5.00 -4.61 4.61 11.38 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 2621 S Birch St - 101119515 & 20182981 7/24/2024 Beam on Elastic Foundation LIC# : KW-06015027, Build:20.23.12.07 GeoStructural, LLC (c) ENERCALC INC 1983-2023 DESCRIPTION:Slab On Grade - "Beam" on Soil Spring Design GeoStructural LLC Jesse Drennen, PE Project File: 3 GEN calcs MERGE.ec6 Project Title:AT&T Generator Upgrade Project Engineer:Jesse Drennen, PE Project ID: Project Descr:Standby Generator on Concrete Slab Detailed Shear Information Load Combination Vu (k)Span Distance 'd'Comment Phi*Vs Req'd d*Vu/MuMu (ft)(k)(in)Actual Suggest(k-ft)Number (k) Spacing (in) Design Phi*Vc +1.405D+E 1 5.18 5.00 -4.50 4.50 10.83 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 5.29 5.00 -4.38 4.38 10.30 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 5.41 5.00 -4.27 4.27 9.78 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 5.53 5.00 -4.15 4.15 9.28 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 5.65 5.00 -4.04 4.04 8.78 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 5.76 5.00 -3.92 3.92 8.31 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 5.88 5.00 -3.81 3.81 7.84 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 6.00 5.00 -3.69 3.69 7.39 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 6.12 5.00 -3.58 3.58 6.95 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 6.24 5.00 -3.46 3.46 6.53 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 6.35 5.00 -3.34 3.34 6.12 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 6.47 5.00 -3.23 3.23 5.72 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 6.59 5.00 -3.11 3.11 5.34 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 6.71 5.00 -3.00 3.00 4.97 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 6.82 5.00 -2.88 2.88 4.61 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 6.94 5.00 -2.77 2.77 4.27 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 7.06 5.00 -2.65 2.65 3.94 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 7.18 5.00 -2.54 2.54 3.63 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 7.29 5.00 -2.42 2.42 3.33 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 7.41 5.00 -2.31 2.31 3.04 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 7.53 5.00 -2.19 2.19 2.76 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 7.65 5.00 -2.08 2.08 2.50 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 7.76 5.00 -1.97 1.97 2.25 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 7.88 5.00 -1.85 1.85 2.02 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 8.00 5.00 -1.74 1.74 1.80 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 8.12 5.00 -1.63 1.63 1.59 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 8.24 5.00 -1.52 1.52 1.39 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 8.35 5.00 -1.41 1.41 1.21 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 8.47 5.00 -1.30 1.30 1.04 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 8.59 5.00 -1.19 1.19 0.89 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 8.71 5.00 -1.08 1.08 0.74 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 8.82 5.00 -0.97 0.97 0.61 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 8.94 5.00 -0.87 0.87 0.50 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 9.06 5.00 -0.76 0.76 0.39 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 9.18 5.00 -0.65 0.65 0.30 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 9.29 5.00 -0.55 0.55 0.22 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 9.41 5.00 -0.44 0.44 0.15 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 9.53 5.00 -0.34 0.34 0.10 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 9.65 5.00 -0.23 0.23 0.05 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +1.405D+E 1 9.76 5.00 -0.13 0.13 0.02 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 +0.6954D-E 1 9.88 5.00 0.03 0.03 0.00 1.00 20.01 Vu < PhiVc/2 Not Reqd 0.00 0.00 2621 S Birch St - 101119515 & 20182981 7/24/2024 Company:Date:9/15/2023 Engineer:Page:1/6 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2403.1 1.Project information Project description: Location: Fastening description: Comment: 2. Input Data & Anchor Parameters General Design method:ACI 318-19 Units: Imperial units Anchor Information: Anchor type: Torque controlled expansion anchor Material: Stainless Steel Diameter (inch): 0.625 Nominal Embedment depth (inch): 5.125 Effective Embedment depth, hef (inch): 4.500 Code report: ICC-ES ESR-3037 Anchor category: 1 Anchor ductility: Yes hmin (inch): 7.88 cac (inch): 9.00 Cmin (inch): 5.50 Smin (inch): 6.25 Base Material Concrete: Normal-weight Concrete thickness, h (inch): 9.00 State: Cracked Compressive strength, f’c (psi): 2500 Ψc,V: 1.0 Reinforcement condition: Supplementary reinforcement not present Supplemental edge reinforcement: Not applicable Reinforcement provided at corners: No Ignore concrete breakout in tension: No Ignore concrete breakout in shear: No Ignore 6do requirement: Not applicable Build-up grout pad: No Base Plate Length x Width x Thickness (inch): 34.50 x 106.00 x 0.38 Recommended Anchor Anchor Name: Strong-Bolt® 2 Stainless Steel - 5/8"Ø STB2SS, hnom:5.125" (130mm) Code Report: ICC-ES ESR-3037 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com 2621 S Birch St - 101119515 & 20182981 7/24/2024 Company:Date:9/15/2023 Engineer:Page:2/6 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2403.1 Load and Geometry Load factor source: ACI 318 Section 5.3 Load combination: not set Seismic design: No Anchors subjected to sustained tension: Not applicable Apply entire shear load at front row: Yes Anchors only resisting wind and/or seismic loads: No Strength level loads: Nua [lb]: -3106 Vuax [lb]: -3120 Vuay [lb]: 0 Mux [ft-lb]: 0 Muy [ft-lb]: -8640 Muz [ft-lb]: 0 <Figure 1> Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com 2621 S Birch St - 101119515 & 20182981 7/24/2024 Company:Date:9/15/2023 Engineer:Page:3/6 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2403.1 <Figure 2> 3. Resulting Anchor Forces Anchor Tension load, Nua (lb) Shear load x, Vuax (lb) Shear load y, Vuay (lb) Shear load combined, √(Vuax)²+(Vuay)² (lb) 1 417.2 -277.7 52.6 282.7 2 418.7 -352.6 52.6 356.5 3 420.1 -427.4 52.6 430.7 4 421.5 -502.3 52.6 505.0 5 0.0 -502.3 -52.6 505.0 6 0.0 -427.4 -52.6 430.7 7 0.0 -352.6 -52.6 356.5 8 0.0 -277.7 -52.6 282.7 Sum 1677.5 -3120.0 0.0 3149.7 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com 2621 S Birch St - 101119515 & 20182981 7/24/2024 Company:Date:9/15/2023 Engineer:Page:4/6 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2403.1 Maximum concrete compression strain (‰): 0.01 Maximum concrete compression stress (psi): 29 Resultant tension force (lb): 1678 Resultant compression force (lb): 4784 Eccentricity of resultant tension forces in x-axis, e'Nx (inch): 0.10 Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00 Eccentricity of resultant shear forces in x-axis, e'Vx (inch): 0.00 Eccentricity of resultant shear forces in y-axis, e'Vy (inch): 0.00 <Figure 3> 4. Steel Strength of Anchor in Tension (Sec. 17.6.1) Nsa (lb)Nsa (lb) 17930 0.75 13448 5. Concrete Breakout Strength of Anchor in Tension (Sec. 17.6.2) Nb = kc a f’chef1.5 (Eq. 17.6.2.2.1) kc a f’c (psi)hef (in)Nb (lb) 17.0 1.00 2500 4.500 8114 Ncbg =(ANc / ANco)ec,N ed,N c,N cp,NNb (Sec. 17.5.1.2 & Eq. 17.6.2.1a) ANc (in2)ANco (in2)ca,min (in)ec,N ed,N c,N cp,N Nb (lb)Ncbg (lb) 729.00 182.25 8.25 0.986 1.000 1.00 1.000 8114 0.65 20800 6. Pullout Strength of Anchor in Tension (Sec. 17.6.3) Npn =c,P aNp(f’c /2,500)n (Sec. 17.5.1.2, Eq. 17.6.3.1 & Code Report) c,P a Np (lb)f’c (psi)n Npn (lb) 1.0 1.00 6545 2500 0.40 0.65 4254 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com 2621 S Birch St - 101119515 & 20182981 7/24/2024 Company:Date:9/15/2023 Engineer:Page:5/6 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2403.1 8. Steel Strength of Anchor in Shear (Sec. 17.7.1) Vsa (lb)grout grout Vsa (lb) 10760 1.0 0.65 6994 9. Concrete Breakout Strength of Anchor in Shear (Sec. 17.7.2) Shear perpendicular to edge in y-direction: Vby =min|7(le / da)0.2 da a f’cca11.5; 9 a f’cca11.5| (Eq. 17.7.2.2.1a & Eq. 17.7.2.2.1b) le (in)da (in)a f’c (psi)ca1 (in)Vby (lb) 4.50 0.625 1.00 2500 19.00 34010 Vcbgy =(AVc / AVco)ec,V ed,V c,V h,VVby (Sec. 17.5.1.2 & Eq. 17.7.2.1b) AVc (in2)AVco (in2)ec,V ed,V c,V h,V Vby (lb)Vcbgy (lb) 330.75 1624.50 1.000 0.787 1.000 1.780 34010 0.70 6787 Shear perpendicular to edge in x-direction: Vbx =min|7(le / da)0.2 da a f’cca11.5; 9 a f’cca11.5| (Eq. 17.7.2.2.1a & Eq. 17.7.2.2.1b) le (in)da (in)a f’c (psi)ca1 (in)Vbx (lb) 4.50 0.625 1.00 2500 8.25 9731 Vcbgx =(AVc / AVco)ec,V ed,V c,V h,VVbx (Sec. 17.5.1.2 & Eq. 17.7.2.1b) AVc (in2)AVco (in2)ec,V ed,V c,V h,V Vbx (lb)Vcbgx (lb) 827.55 306.28 0.697 1.000 1.000 1.173 9731 0.70 15047 Shear parallel to edge in x-direction: Vby =min|7(le / da)0.2 da a f’cca11.5; 9 a f’cca11.5| (Eq. 17.7.2.2.1a & Eq. 17.7.2.2.1b) le (in)da (in)a f’c (psi)ca1 (in)Vby (lb) 4.50 0.625 1.00 2500 8.25 9731 Vcbgx =(2)(AVc / AVco)ec,V ed,V c,V h,VVby (Sec. 17.5.1.2, 17.7.2.1(c) & Eq. 17.7.2.1b) AVc (in2)AVco (in2)ec,V ed,V c,V h,V Vby (lb)Vcbgx (lb) 827.55 306.28 1.000 1.000 1.000 1.173 9731 0.70 43163 Shear parallel to edge in y-direction: Vbx =min|7(le / da)0.2 da a f’cca11.5; 9 a f’cca11.5| (Eq. 17.7.2.2.1a & Eq. 17.7.2.2.1b) le (in)da (in)a f’c (psi)ca1 (in)Vbx (lb) 4.50 0.625 1.00 2500 10.50 13972 Vcbgy =(2)(AVc / AVco)ec,V ed,V c,V h,VVbx (Sec. 17.5.1.2, 17.7.2.1(c) & Eq. 17.7.2.1b) AVc (in2)AVco (in2)ec,V ed,V c,V h,V Vbx (lb)Vcbgy (lb) 432.00 496.13 1.000 1.000 1.000 1.323 13972 0.70 22532 10. Concrete Pryout Strength of Anchor in Shear (Sec. 17.7.3) Vcp =kcpNcb =kcp(ANc / ANco)ed,N c,N cp,NNb (Sec. 17.5.1.2 & Eq. 17.7.3.1a) kcp ANc (in2)ANco (in2)ed,N c,N cp,N Nb (lb)Vcp (lb) 2.0 182.25 182.25 1.000 1.000 1.000 8114 0.70 11360 11. Results Interaction of Tensile and Shear Forces (Sec. 17.8) Tension Factored Load, Nua (lb)Design Strength, øNn (lb)Ratio Status Steel 422 13448 0.03 Pass Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com 2621 S Birch St - 101119515 & 20182981 7/24/2024 Company:Date:9/15/2023 Engineer:Page:6/6 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2403.1 Concrete breakout 1678 20800 0.08 Pass Pullout 422 4254 0.10 Pass (Governs) Shear Factored Load, Vua (lb)Design Strength, øVn (lb)Ratio Status Steel 505 6994 0.07 Pass T Concrete breakout y- 211 6787 0.03 Pass T Concrete breakout x- 3120 15047 0.21 Pass || Concrete breakout x- 211 43163 0.00 Pass || Concrete breakout y+ 1005 22532 0.04 Pass Concrete breakout, combined --0.21 Pass (Governs) Pryout 505 11360 0.04 Pass Interaction check Nua/Nn Vua/Vn Combined Ratio Permissible Status Sec. 17.8.2 0.00 0.21 21.0%1.0 Pass 5/8"Ø STB2SS, hnom:5.125" (130mm) meets the selected design criteria. 12. Warnings - Designer must exercise own judgement to determine if this design is suitable. - Refer to manufacturer’s product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com 2621 S Birch St - 101119515 & 20182981 7/24/2024 GENERA.L DVNAIVIICS Wireless Services January 24, 2024 RE: letter of Authorization -Brius Telecom Solutions LLC/Small Cell Solutions Inc. To Whom it May Concern: Brius Telecom Solutions LLC/Small C ell Solutions Inc. and its employees Henry French and Bryan Tran are authorized as representatives of General Dynamics to conduct business on its behalf for the purpose of obtaining any leasing entitlements, permits, or other jurisdictional approvals necessary to complete pre-construction requirements for the subject project under its AT&T Generator program . If you have any questions, please don't hesitate to reach out to myself at the phone number or email address below. Sincerely, Landis Schmehr, PMP Program Manger General Dyn a mics Information Technology 619-402-8490 Cell landis.schme hr@gdit.com Genera l Dynamics Wireless Services 2311 S Sierra Park Trail Show Low, AZ 85901 Page 1 of 1 2621 S Birch St - 101119515 & 20182981 7/24/2024 NOTARY ACKNOWLEDGMENT A notary public or other officer comp leting this certifi cate verifies only the id entity of the individual who signed the docu ment to wh ich this cert ifi cate is attached, and not the truthfulness, accuracy , or va lidity of that document. State of Ai ZOV\_ll, County of N (1\/0C; D onD (AV\ VJl~ ) /_p , 20,aLi_ before m~a.caUWll w 1'~1: 1'11) tllvy (name and ti t le of offi er), personally appeared [C\\ ~Sc\/\ YYl-l who proved to me on the basis of satisfactory evidence to be the pers on(s) whos e name(s) is/are subscribed to the within instrument and acknowledged to me that she/she/they executed the same in his/he r/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the enti ty upon behalf of which the person(s) acted, execute d the instrument. I certify under PENAL TY OF PERJURY under the laws of the State of that the foregoing paragraph is true and correct. AY\2DVlO\J W ITNESS my hand a official seal. (Seal) , Jacqueline Perpignani _ , Notary Public -Navajo County -Arizona Commission #630222 My Commission Expires July 12, 2026 Page 1 of 1 2621 S Birch St - 101119515 & 20182981 7/24/2024 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 2621 S Birch St - 101119515 & 20182981 7/24/2024 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City Official Requesting Review: City Reference #: __________________________ City / County: _____________________________________ Date: __________________________________ Contact Name: _____________________________________ E-Mail: __________________________________ Title: _____________________________________ Phone #: _________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County: OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ Updated: 08/30/2021 2621 S Birch St - 101119515 & 20182981 7/24/2024