HomeMy WebLinkAbout3321 S Bristol St - 101118470 - PlanSHEETS - ARCHITECTURAL SP0 COVER SHEET 11 . 1 5 . 2 0 2 2 DATE OF ISSUE PROJECT DATA DRAWING INDEX SMD1 SHUTTER DRAWINGS & PLAN SCOPE OF WORK: · EXISTING MERCANTILE OCCUPANCY · INSTALLATION OF SECURITY SHUTTERS · NO PLUMBING UNDER THIS SCOPE OF WORK · NO MECHANICAL UNDER THIS SCOPE OF WORK · NO ELECTRICAL UNDER THIS SCOPE OF WORK SCOPE OF WORK SME SHUTTER DETAILS SHUTTER DRAWINGS SP0 COVER SHEET CORTLAND MORGAN ARCHITECT KEY MAP VICINITY MAP ROSS ROSS 711 FIELDER ROAD ARLINGTON, TX 76012 TRICIA RUSSELL (817) 635-5696 EXT 101 SD STRUCTURAL DRAWING STORE #2388 3321 S BRISTOL ST SANTA ANA, CA 92704 CODE ANALYSIS TOTAL BUILDING: 21,043 SQ.FT. TOTAL SALES FLOOR: 15,082 SQ.FT. APPLICABLE CODES: BUILDING 2022 CALIFORNIA BUILDING CODE/CITY OF SANTA ANA MUNICIPLE CODE MECHANICAL 2022 CALIFORNIA MECHANICAL CODE PLUMBING 2022 CALIFORNIA PLUMBING CODE ELECTRICAL 2022 CALIFORNIAL ELECTRICAL CODE FIRE PROTECTION 2022 CALIFORNIA FIRE CODE ACCESSIBILITY TITLE 24 STANDARDS FIRE BUILDING INFO: CONSTRUCTION TYPE:TYPE II-B OCCUPANCY GROUP:MERCANTILE GROSS LEASE AREA:21,043 SQ. FT. TOTAL OCCUPANT LOAD: 1-500 2 EXITS REQUIRED) EXIT REQUIREMENTS (2) EXITS REQUIRED; (2) PROVIDED AUTOMATIC SPRINKLER SYSTEM:YES LIFE SAFETY MASTER PLAN ENERGY 2022 CALIFORNIA ENERGY CODE ARCHITECT BUILDING DEPARTMENT CALIFORNIA GREEN 2022 CALIFORNIA GREEN BUILDING STANDARDS (CGC) (PART 11) CITY OF SANTA ANA BUILDING DEPARTMENT 20 CIVIC CENTER PLAZA ROSS ANNEX, M-20 SANTA ANA, CA 92702 PHONE: 714-667-2700 Date 11/15/2022 Project Number Drawn /Checked: STAFF / CM No . D e s c r i p t i o n Da t e SH U T T E R D R A W I N G S Sheet Title Sheet Number Re v i s i o n s ST O R E # 2 3 8 8 33 2 1 S B R I S T O L S T SA N T A A N A , C A 9 2 7 0 4 10 . 1 7 . 2 0 2 3 R E V 1 CENTER SITE PLAN ROSS 2 PL A N R E V C O M M E N T S 2 04 . 1 7 . 2 4 SMD2 EGRESS PLAN 04 . 1 7 . 2 0 2 4 R E V 2 2 Bldg# 101118470 APPROVALS: PLNG - MKilroy BLDG - WLee POLICE - BMartin 3321 S Bristol St - 1011184705/21/2024 SD STRUCTURAL DRAWING Date 8/30/2022 Project Number Drawn /Checked: STAFF / CM No . D e s c r i p t i o n Da t e SH U T T E R D R A W I N G S Sheet Title Sheet Number Re v i s i o n s S T O R E # 2 3 3 8 3 3 2 1 S B R I S T O L S T S A N T A A N A , C A 9 2 7 0 4 DESIGN CRITERIA Ss = 1.284 Sds = 1.027 ap = 1.0 Rp = 2.5 Ip = 1.0 PE STAMP REFERS ONLY TO ANCHORAGE CALCULATION OF SHUTTER ASSEMBLY TO BACKUP STRUCTURE. DOES NOT APPLY TO ANY OTHER ELEMENT OR SYSTEM. 09/06/2022 3321 S Bristol St - 1011184705/21/2024 NEW SHUTTERS MOUNTED ON THE INTERIOR OF EXISTING OPENINGS L RAMJET TC-220T 5 4 3 2 1 B A WI N D O W WI N D O W WI N D O W 1'-0" WI N D O W WI N D O W WI N D O W WI N D O W WI N D O W 30 ' - 1 0 " 5' - 1 " 3' - 2 " SMD1 SHUTTER DRAWINGS FLOOR PLAN SCALE: 1/16" =1'-0" 1GENERAL NOTES THE WEIGHT OF THE SHUTTERS IS CARRIED BY THE CEMENT FLOOR SHUTTERS DO NOT REDUCE EGRESS WIDTH. SHUTTERS ON DOUBLE DOORS = 69 14 " DOUBLE DOOR CLEAR OPENING = 68" THE VERTICAL SECURITY GRILLES SHALL BE OPENABLE FROM THE INSIDE WITH OUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT DURING PERIODS THAT THE SPACE IS OCCUPIED. THE GRILLES SHALL REMAIN IN THE FULL OPEN POSITION DURING THE PERIOD OF OCCUPANCY BY THE GENERAL PUBLIC SHUTTERS MUST REMAIN OPEN DURING BUSINESS HOURS AND LOCATION PLAN Date 11/15/2022 Project Number Drawn /Checked: STAFF / CM No . D e s c r i p t i o n Da t e SH U T T E R D R A W I N G S Sheet Title Sheet Number Re v i s i o n s S T O R E # 2 3 8 8 3 3 2 1 S B R I S T O L S T S A N T A A N A , C A 9 2 7 0 4 3321 S Bristol St - 1011184705/21/2024 L RAMJET TC-220T 5 4 3 2 1 B A CO M P A C T O R ROOF HATCH ACCESS POINT M 24" x 48" BENCH30"x48" CLEAR SPACE M M M M M M M WI N D O W WI N D O W COR N E R SHO W C A S E 48" 3/4 VIEWJEWELRYSHOWCASE ROSS-LEFT-2x2 POST HCSPONYWALL & SWING GATE ROSS-LEFT-112" INLINEPONYWALL & SWING GATE ROSS-RIGHT-112" INLINEPONYWALL & SWING GATE DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PIN P A D SC A N N E R PRINTER DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PI N P A D SC A N N E R PRINTER DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PI N P A D SC A N N E R PRINTER DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PI N P A D SC A N N E R PRINTER DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PI N P A D SC A N N E R PRINTER DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PI N P A D SC A N N E R PRINTER DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PI N P A D SC A N N E R DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PI N P A D SC A N N E R PRINTER 1'-0" M 4'- 0 " 3'-8" 6'-6" 4'-10" 3'-8" 3' - 8 " 3'-8" WI N D O W WI N D O W WI N D O W WI N D O W WI N D O W WI N D O W WI N D O W 5'-0" 1'-0" 2' - 7 " 2'-10" 12 ' - 2 " 2' - 9 " 33 ' - 0 " 13'-11" 55 ' - 1 1 " 5' - 8 " 15'-7" 1'-0" 10 ' - 0 " 13 ' - 0 " 4'-9" 4' - 0 " 4' - 0 " 4' - 0 " 17 ' - 0 " 6'-1" 6'-8" 7'-6" 5'-0" 4'-7" 4'-5" 4' - 0 " 4' - 0 " 4' - 0 " 1' - 0 " 5'-5" 4'-5"6'-8" 3' - 6 " 4' - 0 " 4' - 2 " 3' - 8 " 3' - 6 " 3' - 6 " 3' - 8 " 5' - 0 " 4' - 5 " 5'-0"3'-8" 4'-0" 3' - 0 " 4'-0"4'-0" 7'-0" 3' - 0 " 3' - 0 " 3' - 0 " 3' - 9 " 4' - 6 " 4' - 6 " 4' - 6 " 3'-3"3'-7"3'-11" 15'-4" 5' - 0 " 4' - 0 " 7' - 0 " 4' - 7 " 3' - 0 " 3' - 8 " 6'-1" 4'-6"4'-6"4'-6" 4'-7" 3' - 1 0 " 4'-6" 3' - 3 " 4'-6" 7' - 0 " 3'-8"3'-8"4'-5"4'-6"4'-6"5'-8" 4'-6" 4' - 3 " 3' - 0 " 3' - 8 " 6'-6" 4'-10" 3'-8" 3' - 8 " 3'-8"4' - 1 1 " 32 ' - 6 " 3' - 8 " 5'-0" 4'-9"3'-11"3'-10"3'-11"3'-11"3'-11"3'-11"3'-11" 5' - 2 " 4' - 4 " 4'-0" 4' - 0 " 4' - 0 " 4' - 0 " 4' - 0 " 4' - 0 " 4' - 0 " 4' - 0 " 4' - 0 " 22 ' - 1 1 " 38 ' - 9 " 5'-0" 4'-5" 2'-8" 1' - 5 " 1' - 7 " 1'-0" 4' - 1 0 " 30 ' - 1 0 " 3' - 1 0 " 2' - 7 " 2'-10" 12 ' - 2 " 2' - 9 " 33 ' - 0 " 13'-11" 55 ' - 1 1 " 5' - 1 " 3' - 5 " 3' - 7 " 5' - 8 " 15'-7" 1'-0" 6' - 5 " 3' - 8 " 6' - 5 " 3'-4" 2'-11" 3'-5" 5' - 4 " 4'-7" 34 " H I G H AD A C A B I N E T 34 " H I G H AD A C A B I N E T 60 " 3 / 4 V I E W JE W E L R Y SH O W C A S E 60 " 3 / 4 V I E W JE W E L R Y SH O W C A S E 60 " 3 / 4 V I E W JE W E L R Y SH O W C A S E 5'-4"5'-4"5'-4" 3' - 2 " TR A V E L D I S T A N C E = 1 7 2 ' - 8 " TR A V E L D I S T A N C E = 1 5 9 ' - 0 " TRAVEL DISTANCE = 114'-2" TRAVEL DISTANCE = 158'-4" M 24 " x 4 8 " BE N C H 30 " x 4 8 " CL E A R SP A C E EGRESS PLAN SCALE: 3/32" =1'-0" Date 11/15/2022 Project Number Drawn /Checked: STAFF / CM No . D e s c r i p t i o n Da t e SH U T T E R D R A W I N G S Sheet Title Sheet Number Re v i s i o n s S T O R E # 2 3 8 8 3 3 2 1 S B R I S T O L S T S A N T A A N A , C A 9 2 7 0 4 EXIT #1 128" EXIT #2 36" SALES M-OCCUPANCY STOCK ROOM S1-OCCUPANCY OFFICES B-OCCUPANCY SMD2 EGRESS PLAN 2 PL A N R E V C O M M E N T S 2 04 . 1 7 . 2 4 3321 S Bristol St - 1011184705/21/2024 SME SHUTTER DRAWINGS Date 11/15/2022 Project Number Drawn /Checked: STAFF / CM No . D e s c r i p t i o n Da t e SH U T T E R D R A W I N G S Sheet Title Sheet Number Re v i s i o n s S T O R E # 2 3 8 8 3 3 2 1 S B R I S T O L S T S A N T A A N A , C A 9 2 7 0 4 3321 S Bristol St - 1011184705/21/2024 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 3321 S Bristol St - 1011184705/21/2024 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 3321 S Bristol St - 1011184705/21/2024 Project No.Sheet No. 1/4 Project Prepared By Date 9/1/2022 Fixture Type Maximum Spacing of Screws Required for 16 GA Aluminum Mullion Security Screen 14 in o.c. Aluminum Mullion (Pull-out in 16 GA Aluminum = 73 lbs.) These values are for seismic pull-out anchorage only, not for component analysis. Gravity load of the assembly is carried by the vertical rails per the manufacturer. Component assembly and attachments per manufacturer. These values are for worst case fixture types and screw size. As the assembly is installed on the interior of the building, no wind load need be considered. ARW Engineers | 1594 West Park Circle, Ogden, Utah | (801) 782-6008 | www.arwengineers.com Use #10 self tapping/drilling (min) screws(min. 3/4" long). Screws are to meet the min. requirements of ADM. (see manufacturer for additional requirements) 22093.L Ross #2388 Santa Ana, CA Santa Ana CA NGW Summary of Seismic Attachments for Security Screen 09/06/2022 3321 S Bristol St - 1011184705/21/2024 Project No.Sheet No. 2/4 Project Prepared By Date 9/1/2022 Building Code Reference Document ASCE7-16 Site Coordinates 33.7021539, -117.8843451 Site Class D-default Seismic Design Category D Risk Category II USGS–Provided Output Ss =1.284 g SMS =1.541 g SDS =1.027 g This project only requires an SDS value (ASCE 7-16 § 13.3) 22093.L NGW Ross #2388 Santa Ana, CA Santa Ana CA Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject-matter knowledge. Design Maps Summary Report 3321 S Bristol St - 1011184705/21/2024 Project No.Sheet No. 3/4 Project Prepared By Date 9/1/2022 ASCE 7-16 (13.3) Component Analysis ap 1.0 Component amplification factor, varies from 1.0-2.5 (Table 13.5-1 or 13.6-1) SDS 1.027 Section 11.4.4 Ip 1.0 Component importance factor, varies from 1.0 to 1.5 (Section 13.1.3) Wp 2.7 psf Component operating weight* Rp 2.5 Component response modification factor, varies from 1.5 to 5.0 (Table13.5-1 or 13.6-1) z 11.458333 ft h 20 ft Average roof height of structure with respect to the base w 144 in Width of opening s 14 in o.c.Spacing of screws along track Seismic force shall be determined in accordance with Equation13.3-1 - 13.3-3: Fp1 = 0.95 psf (Equation 13.3-1) Seismic force not required to be taken as greater than: Fp2 = 4.44 psf (Equation 13.3-2) And seismic force shall not be taken as less than: Fp3 = 0.83 psf (Equation 13.3-3) Selects the appropriate seismic force from above Fp = 0.95 psf Force tributary to side rails wE = 5.71 plf Pull-out force per screw PE = 6.66 lbs 22093.L NGW Height in structure of point of attachment of component with respect to the base. For items at or below the base, z = 0. Value of z/h < 1 Ross #2388 Santa Ana, CA Santa Ana CA  0.4 · · ·    ·1  2 ·  ℎ 1.6 · ··  0.3 · ··  Seismic Attachment for Security  ∗ 2  ∗ 3321 S Bristol St - 1011184705/21/2024 Project No.Sheet No. 4/4 Project Prepared By Date 9/1/2022 For Anchoring Into Aluminum Mullion (16 gage minimum) Seismic Force Fp = 6.7 lbs Screw Type Pull-Out (ea)ΦRn = 73 lbs (ADM 2015 EQ J.5-4) OK Seismic Force Fp = 130.9 lbs Screw Type (2) screws total ΦRn = 147 lbs (ADM 2015 EQ J.5-4) OK Ross #2388 Santa Ana, CA Santa Ana CA 22093.L Use (1) #10 self tapping/drilling (min) screw (min 3/4" long) each end (min) to attach the housing to minimum 16 GA aluminum mullion #10 self tapping/drilling (min) NGW #10 self tapping/drilling (min) Use #10 self tapping/drilling (min) screws (min 3/4" long) @ 14" o.c. to attach the screen track and housing to minimum 16 GA aluminum mullion Seismic Anchoring For Pull-Out Only (Shutter Closed) Seismic Anchoring For Pull-Out Only (Shutter Open) (all load applied to shutter housing) 3321 S Bristol St - 1011184705/21/2024 SHEETS - ARCHITECTURAL SP0 COVER SHEET 11 . 1 5 . 2 0 2 2 DATE OF ISSUE PROJECT DATA DRAWING INDEX SMD1 SHUTTER DRAWINGS & PLAN SCOPE OF WORK: · EXISTING MERCANTILE OCCUPANCY · INSTALLATION OF SECURITY SHUTTERS · NO PLUMBING UNDER THIS SCOPE OF WORK · NO MECHANICAL UNDER THIS SCOPE OF WORK · NO ELECTRICAL UNDER THIS SCOPE OF WORK SCOPE OF WORK SME SHUTTER DETAILS SHUTTER DRAWINGS SP0 COVER SHEET CORTLAND MORGAN ARCHITECT KEY MAP VICINITY MAP ROSS ROSS 711 FIELDER ROAD ARLINGTON, TX 76012 TRICIA RUSSELL (817) 635-5696 EXT 101 SD STRUCTURAL DRAWING STORE #2388 3321 S BRISTOL ST SANTA ANA, CA 92704 CODE ANALYSIS TOTAL BUILDING: 21,043 SQ.FT. TOTAL SALES FLOOR: 15,082 SQ.FT. APPLICABLE CODES: BUILDING 2022 CALIFORNIA BUILDING CODE/CITY OF SANTA ANA MUNICIPLE CODE MECHANICAL 2022 CALIFORNIA MECHANICAL CODE PLUMBING 2022 CALIFORNIA PLUMBING CODE ELECTRICAL 2022 CALIFORNIAL ELECTRICAL CODE FIRE PROTECTION 2022 CALIFORNIA FIRE CODE ACCESSIBILITY TITLE 24 STANDARDS FIRE BUILDING INFO: CONSTRUCTION TYPE:TYPE II-B OCCUPANCY GROUP:MERCANTILE GROSS LEASE AREA:21,043 SQ. FT. TOTAL OCCUPANT LOAD: 1-500 2 EXITS REQUIRED) EXIT REQUIREMENTS (2) EXITS REQUIRED; (2) PROVIDED AUTOMATIC SPRINKLER SYSTEM:YES LIFE SAFETY MASTER PLAN ENERGY 2022 CALIFORNIA ENERGY CODE ARCHITECT BUILDING DEPARTMENT CALIFORNIA GREEN 2022 CALIFORNIA GREEN BUILDING STANDARDS (CGC) (PART 11) CITY OF SANTA ANA BUILDING DEPARTMENT 20 CIVIC CENTER PLAZA ROSS ANNEX, M-20 SANTA ANA, CA 92702 PHONE: 714-667-2700 Date 11/15/2022 Project Number Drawn /Checked: STAFF / CM No . D e s c r i p t i o n Da t e SH U T T E R D R A W I N G S Sheet Title Sheet Number Re v i s i o n s ST O R E # 2 3 8 8 33 2 1 S B R I S T O L S T SA N T A A N A , C A 9 2 7 0 4 10 . 1 7 . 2 0 2 3 R E V 1 CENTER SITE PLAN ROSS 2 PL A N R E V C O M M E N T S 2 04 . 1 7 . 2 4 SMD2 EGRESS PLAN 04 . 1 7 . 2 0 2 4 R E V 2 2 Bldg# 101118470 APPROVALS: PLNG - MKilroy BLDG - WLee POLICE - BMartin 3321 S Bristol St - 1011184705/21/2024 SD STRUCTURAL DRAWING Date 8/30/2022 Project Number Drawn /Checked: STAFF / CM No . D e s c r i p t i o n Da t e SH U T T E R D R A W I N G S Sheet Title Sheet Number Re v i s i o n s S T O R E # 2 3 3 8 3 3 2 1 S B R I S T O L S T S A N T A A N A , C A 9 2 7 0 4 DESIGN CRITERIA Ss = 1.284 Sds = 1.027 ap = 1.0 Rp = 2.5 Ip = 1.0 PE STAMP REFERS ONLY TO ANCHORAGE CALCULATION OF SHUTTER ASSEMBLY TO BACKUP STRUCTURE. DOES NOT APPLY TO ANY OTHER ELEMENT OR SYSTEM. 09/06/2022 3321 S Bristol St - 1011184705/21/2024 NEW SHUTTERS MOUNTED ON THE INTERIOR OF EXISTING OPENINGS L RAMJET TC-220T 5 4 3 2 1 B A WI N D O W WI N D O W WI N D O W 1'-0" WI N D O W WI N D O W WI N D O W WI N D O W WI N D O W 30 ' - 1 0 " 5' - 1 " 3' - 2 " SMD1 SHUTTER DRAWINGS FLOOR PLAN SCALE: 1/16" =1'-0" 1GENERAL NOTES THE WEIGHT OF THE SHUTTERS IS CARRIED BY THE CEMENT FLOOR SHUTTERS DO NOT REDUCE EGRESS WIDTH. SHUTTERS ON DOUBLE DOORS = 69 14 " DOUBLE DOOR CLEAR OPENING = 68" THE VERTICAL SECURITY GRILLES SHALL BE OPENABLE FROM THE INSIDE WITH OUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT DURING PERIODS THAT THE SPACE IS OCCUPIED. THE GRILLES SHALL REMAIN IN THE FULL OPEN POSITION DURING THE PERIOD OF OCCUPANCY BY THE GENERAL PUBLIC SHUTTERS MUST REMAIN OPEN DURING BUSINESS HOURS AND LOCATION PLAN Date 11/15/2022 Project Number Drawn /Checked: STAFF / CM No . D e s c r i p t i o n Da t e SH U T T E R D R A W I N G S Sheet Title Sheet Number Re v i s i o n s S T O R E # 2 3 8 8 3 3 2 1 S B R I S T O L S T S A N T A A N A , C A 9 2 7 0 4 3321 S Bristol St - 1011184705/21/2024 L RAMJET TC-220T 5 4 3 2 1 B A CO M P A C T O R ROOF HATCH ACCESS POINT M 24" x 48" BENCH30"x48" CLEAR SPACE M M M M M M M WI N D O W WI N D O W COR N E R SHO W C A S E 48" 3/4 VIEWJEWELRYSHOWCASE ROSS-LEFT-2x2 POST HCSPONYWALL & SWING GATE ROSS-LEFT-112" INLINEPONYWALL & SWING GATE ROSS-RIGHT-112" INLINEPONYWALL & SWING GATE DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PIN P A D SC A N N E R PRINTER DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PI N P A D SC A N N E R PRINTER DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PI N P A D SC A N N E R PRINTER DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PI N P A D SC A N N E R PRINTER DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PI N P A D SC A N N E R PRINTER DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PI N P A D SC A N N E R PRINTER DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PI N P A D SC A N N E R DR O P H O L E FO R S E C U R I T Y T A G S DE T A C H E R PI N P A D SC A N N E R PRINTER 1'-0" M 4'- 0 " 3'-8" 6'-6" 4'-10" 3'-8" 3' - 8 " 3'-8" WI N D O W WI N D O W WI N D O W WI N D O W WI N D O W WI N D O W WI N D O W 5'-0" 1'-0" 2' - 7 " 2'-10" 12 ' - 2 " 2' - 9 " 33 ' - 0 " 13'-11" 55 ' - 1 1 " 5' - 8 " 15'-7" 1'-0" 10 ' - 0 " 13 ' - 0 " 4'-9" 4' - 0 " 4' - 0 " 4' - 0 " 17 ' - 0 " 6'-1" 6'-8" 7'-6" 5'-0" 4'-7" 4'-5" 4' - 0 " 4' - 0 " 4' - 0 " 1' - 0 " 5'-5" 4'-5"6'-8" 3' - 6 " 4' - 0 " 4' - 2 " 3' - 8 " 3' - 6 " 3' - 6 " 3' - 8 " 5' - 0 " 4' - 5 " 5'-0"3'-8" 4'-0" 3' - 0 " 4'-0"4'-0" 7'-0" 3' - 0 " 3' - 0 " 3' - 0 " 3' - 9 " 4' - 6 " 4' - 6 " 4' - 6 " 3'-3"3'-7"3'-11" 15'-4" 5' - 0 " 4' - 0 " 7' - 0 " 4' - 7 " 3' - 0 " 3' - 8 " 6'-1" 4'-6"4'-6"4'-6" 4'-7" 3' - 1 0 " 4'-6" 3' - 3 " 4'-6" 7' - 0 " 3'-8"3'-8"4'-5"4'-6"4'-6"5'-8" 4'-6" 4' - 3 " 3' - 0 " 3' - 8 " 6'-6" 4'-10" 3'-8" 3' - 8 " 3'-8"4' - 1 1 " 32 ' - 6 " 3' - 8 " 5'-0" 4'-9"3'-11"3'-10"3'-11"3'-11"3'-11"3'-11"3'-11" 5' - 2 " 4' - 4 " 4'-0" 4' - 0 " 4' - 0 " 4' - 0 " 4' - 0 " 4' - 0 " 4' - 0 " 4' - 0 " 4' - 0 " 22 ' - 1 1 " 38 ' - 9 " 5'-0" 4'-5" 2'-8" 1' - 5 " 1' - 7 " 1'-0" 4' - 1 0 " 30 ' - 1 0 " 3' - 1 0 " 2' - 7 " 2'-10" 12 ' - 2 " 2' - 9 " 33 ' - 0 " 13'-11" 55 ' - 1 1 " 5' - 1 " 3' - 5 " 3' - 7 " 5' - 8 " 15'-7" 1'-0" 6' - 5 " 3' - 8 " 6' - 5 " 3'-4" 2'-11" 3'-5" 5' - 4 " 4'-7" 34 " H I G H AD A C A B I N E T 34 " H I G H AD A C A B I N E T 60 " 3 / 4 V I E W JE W E L R Y SH O W C A S E 60 " 3 / 4 V I E W JE W E L R Y SH O W C A S E 60 " 3 / 4 V I E W JE W E L R Y SH O W C A S E 5'-4"5'-4"5'-4" 3' - 2 " TR A V E L D I S T A N C E = 1 7 2 ' - 8 " TR A V E L D I S T A N C E = 1 5 9 ' - 0 " TRAVEL DISTANCE = 114'-2" TRAVEL DISTANCE = 158'-4" M 24 " x 4 8 " BE N C H 30 " x 4 8 " CL E A R SP A C E EGRESS PLAN SCALE: 3/32" =1'-0" Date 11/15/2022 Project Number Drawn /Checked: STAFF / CM No . D e s c r i p t i o n Da t e SH U T T E R D R A W I N G S Sheet Title Sheet Number Re v i s i o n s S T O R E # 2 3 8 8 3 3 2 1 S B R I S T O L S T S A N T A A N A , C A 9 2 7 0 4 EXIT #1 128" EXIT #2 36" SALES M-OCCUPANCY STOCK ROOM S1-OCCUPANCY OFFICES B-OCCUPANCY SMD2 EGRESS PLAN 2 PL A N R E V C O M M E N T S 2 04 . 1 7 . 2 4 3321 S Bristol St - 1011184705/21/2024 SME SHUTTER DRAWINGS Date 11/15/2022 Project Number Drawn /Checked: STAFF / CM No . D e s c r i p t i o n Da t e SH U T T E R D R A W I N G S Sheet Title Sheet Number Re v i s i o n s S T O R E # 2 3 8 8 3 3 2 1 S B R I S T O L S T S A N T A A N A , C A 9 2 7 0 4 3321 S Bristol St - 1011184705/21/2024 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 3321 S Bristol St - 1011184705/21/2024 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 3321 S Bristol St - 1011184705/21/2024 Project No.Sheet No. 1/4 Project Prepared By Date 9/1/2022 Fixture Type Maximum Spacing of Screws Required for 16 GA Aluminum Mullion Security Screen 14 in o.c. Aluminum Mullion (Pull-out in 16 GA Aluminum = 73 lbs.) These values are for seismic pull-out anchorage only, not for component analysis. Gravity load of the assembly is carried by the vertical rails per the manufacturer. Component assembly and attachments per manufacturer. These values are for worst case fixture types and screw size. As the assembly is installed on the interior of the building, no wind load need be considered. ARW Engineers | 1594 West Park Circle, Ogden, Utah | (801) 782-6008 | www.arwengineers.com Use #10 self tapping/drilling (min) screws(min. 3/4" long). Screws are to meet the min. requirements of ADM. (see manufacturer for additional requirements) 22093.L Ross #2388 Santa Ana, CA Santa Ana CA NGW Summary of Seismic Attachments for Security Screen 09/06/2022 3321 S Bristol St - 1011184705/21/2024 Project No.Sheet No. 2/4 Project Prepared By Date 9/1/2022 Building Code Reference Document ASCE7-16 Site Coordinates 33.7021539, -117.8843451 Site Class D-default Seismic Design Category D Risk Category II USGS–Provided Output Ss =1.284 g SMS =1.541 g SDS =1.027 g This project only requires an SDS value (ASCE 7-16 § 13.3) 22093.L NGW Ross #2388 Santa Ana, CA Santa Ana CA Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject-matter knowledge. Design Maps Summary Report 3321 S Bristol St - 1011184705/21/2024 Project No.Sheet No. 3/4 Project Prepared By Date 9/1/2022 ASCE 7-16 (13.3) Component Analysis ap 1.0 Component amplification factor, varies from 1.0-2.5 (Table 13.5-1 or 13.6-1) SDS 1.027 Section 11.4.4 Ip 1.0 Component importance factor, varies from 1.0 to 1.5 (Section 13.1.3) Wp 2.7 psf Component operating weight* Rp 2.5 Component response modification factor, varies from 1.5 to 5.0 (Table13.5-1 or 13.6-1) z 11.458333 ft h 20 ft Average roof height of structure with respect to the base w 144 in Width of opening s 14 in o.c.Spacing of screws along track Seismic force shall be determined in accordance with Equation13.3-1 - 13.3-3: Fp1 = 0.95 psf (Equation 13.3-1) Seismic force not required to be taken as greater than: Fp2 = 4.44 psf (Equation 13.3-2) And seismic force shall not be taken as less than: Fp3 = 0.83 psf (Equation 13.3-3) Selects the appropriate seismic force from above Fp = 0.95 psf Force tributary to side rails wE = 5.71 plf Pull-out force per screw PE = 6.66 lbs 22093.L NGW Height in structure of point of attachment of component with respect to the base. For items at or below the base, z = 0. Value of z/h < 1 Ross #2388 Santa Ana, CA Santa Ana CA  0.4 · · ·    ·1  2 ·  ℎ 1.6 · ··  0.3 · ··  Seismic Attachment for Security  ∗ 2  ∗ 3321 S Bristol St - 1011184705/21/2024 Project No.Sheet No. 4/4 Project Prepared By Date 9/1/2022 For Anchoring Into Aluminum Mullion (16 gage minimum) Seismic Force Fp = 6.7 lbs Screw Type Pull-Out (ea)ΦRn = 73 lbs (ADM 2015 EQ J.5-4) OK Seismic Force Fp = 130.9 lbs Screw Type (2) screws total ΦRn = 147 lbs (ADM 2015 EQ J.5-4) OK Ross #2388 Santa Ana, CA Santa Ana CA 22093.L Use (1) #10 self tapping/drilling (min) screw (min 3/4" long) each end (min) to attach the housing to minimum 16 GA aluminum mullion #10 self tapping/drilling (min) NGW #10 self tapping/drilling (min) Use #10 self tapping/drilling (min) screws (min 3/4" long) @ 14" o.c. to attach the screen track and housing to minimum 16 GA aluminum mullion Seismic Anchoring For Pull-Out Only (Shutter Closed) Seismic Anchoring For Pull-Out Only (Shutter Open) (all load applied to shutter housing) 3321 S Bristol St - 1011184705/21/2024