HomeMy WebLinkAbout1895 & 1995 S Standard Ave - PlanGENERAL NOTES PROJECT SCOPE:DRAWING INDEXPERMITTING / PLANNING NOTES: ADDRESS MAP AERIAL PHOTO: PROJECT TEAM: CONTRACTOR: THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : 1. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE 2022 TITLE 24 OF THE CALIFORNIA BUILDING CODE, CMC,CPC. CEC AND ALL APPLICABLE LOCAL CODES, ORDINANCES, AND STATE AMENDMENTS. 2. THE CONTRACTOR SHALL CHECK ALL DRAWINGS IMMEDIATELY UPON THEIR RECEIPT AND SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE STARTING WORK. ALL ARCHITECTS AND ENGINEERS SHALL BE NOTIFIED OF ANY DISCREPANCIES. 3. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY SHOWN, NOTED, OR APPROVED BY ALL. NOTCH DETAILS, IF PROVIDED ARE FOR GENERAL GUIDANCE ONLY. ALL SHALL BE CONTACTED TO APPROVE LOCATIONS OF PROPOSED NOTCHES. 4. CONNECTIONS AND IMPLIED CONSTRUCTION ASSEMBLIES THAT ARE NOT SPECIFICALLY DESCRIBED OR DETAILED SHALL BE CONSTRUCTED USING STANDARD CONSTRUCTION PRACTICES IN COMPLIANCE WITH THE GOVERNING CODES AND ORDINANCES. 5. WHEN DETAILS LABELED "TYPICAL” OR "SIMILAR" ARE GIVEN ON DRAWINGS, THE CONTRACTOR SHALL APPLY THE INTENT OF THE DETAIL TO THAT SPECIFIC CONDITION. 6. WRITTEN INFORMATION AND DIMENSIONS SHALL HAVE PRECEDENCE OVER GRAPHIC INFORMATION. DO NOT SCALE. 7. DRAWINGS AND SPECIFICATIONS FOR THIS WORK HAVE BEEN PREPARED IN ACCORDANCE WITH GENERALLY ACCEPTED STANDARDS OF PRACTICE TO MEET THE MINIMUM REQUIREMENTS DF THE CURRENT EDITION DF THE CBC. ANY DISCREPANCIES ON THE PLANS OR ANY DE\/IATIONS FROM THE PLANS WHICH ARE NECESSITATED BY FIELD CONDITIONS OR ANY CONDITION DIFFERENT FROM THOSE INDICATED ON THE PLANS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER. ALL WORK IS TO BE COORDINATED SO THAT COOPERATION BETWEEN THE TRADES WHERE REQUIRED IS ACCOMPLISHED. 8. CONTRACTOR AND SUBCONTRACTORS ARE RESPONSIBLE FOR THE ORDER AND MEANS DF CONSTRUCTION AND ALL TEMPORARY BRACING AND ERECTION DURING CONSTRUCTION. 9. APPROVALS BY BUILDING INSPECTORS SHALL NOT CONSTITUTE AUTHORITY TO DEVIATE FROM THE PLANS AND SPECIFICATIONS 1O. ALL WORK SHALL CONFORM TO TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) 11. GRADING PLANS, DRAINAGE IMPROVEMENTS, ROAD AND ACCESS REQUIREMENTS AND ENVIRONMENTAL HEALTH CONSIDERATIONS SHALL COMPLY WITH ALL LOCAL ORDINANCES. X_____________________________ VICINITY MAP: PROPERTY OWNER: PROLOGIS, L.P. 1800 WAZEE ST, SUITE 500 DENVER, CO 80202 SKYBRIDGE RENEWABLES LLC THIS INSTALLATION CONSISTS OF ROOF MOUNTED PHOTOVOLTAIC (PV) SYSTEM. THE PV SYSTEM IS STATIC MOUNTED. THIS SYSTEM WILL BE INTERCONNECTED TO AND WILL BE OPERATED IN PARALLEL WITH THE ELECTRIC GRID PER THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND UTILITY INTERCONNECT AGREEMENT 1. THIS PV SYSTEM INSTALLATION IS SUBJECT TO INSPECTION BY THE AUTHORITY HAVING JURISDICTION 2. THIS PROJECT SHALL CONFORM TO THE FOLLOWING CODE VERSIONS: 2022 CALIFORNIA BUILDING CODE (CBC 2022) 2022 CALIFORNIA ELECTRIC CODE (CEC 2022) 2022 CALIFORNIA FIRE CODE (CFC 2022) 2022 CALIFORNIA ENERGY CODE (CEnC 2022) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSG 2022) 2022 CALIFORNIA PLUMBING CODE (CPC 2022) 2022 CALIFORNIA MECHANICAL CODE (CMC 2022) AUTHORITY HAVING JURISDICTION 3. PV SYSTEM MEETS FIRE CLASSIFICATION PER CBC 1505.9 CLASS "A". PV SYSTEM AND ASSOCIATED RACKING SYSTEM ARE LISTED AND IDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 1703 & UL 2703. 4. SYSTEM UTILIZES SOLAREDGE INVERTERS AND OPTIMIZERS WHICH MEET 690.12 MODULE LEVEL RAPID SHUTDOWN REQUIREMENTS. 5. 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. 6. THE OUTPUT CHARACTERISTICS OF THE PV SYSTEM SHALL BE COMPATIBLE WITH THE VOLTAGE, WAVE SHAPE, AND FREQUENCY OF THAT OF THE UTILITY OUTPUT. 705.14. 7. INTERCONNECTED ELECTRIC POWER PRODUCTION SOURCES SHALL BE GROUNDED IN ACCORDANCE WITH ARTICLE 250. 705.50. 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 1 1 / 6 / 2 0 2 4 1 0 : 4 8 : 0 8 A M Ut i l i t y C u s t o m e r N a m e : P r o l o g i s L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 1 9 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 Utility Customer Name: Prologis Logistic Serv Inc - Santa Ana Distribution Center 1 1995 S Standard Ave Santa Ana, CA 92707 & 1895 S Standard Ave Santa Ana, CA 92707 SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9230 LIC # C10 - 1112028 PV-1 Ti t l e S h e e t SKYBRIDGE RENEWABLES LLC C10 -1112028 10/31/2025 SOLAR ELECTRIC SYSTEM THIS PROJECT ENTAILS THE INSTALLATION OF A PHOTOVOLTAIC SYSTEM AT Utility Customer Name: Prologis Logistic Serv Inc - Santa Ana Distribution Center 1 THE SYSTEM WILL NOT BE A NET ELECTRICITY EXPORTER TO THE UTILITY GRID. SOLAR ELECTRIC SYSTEM PROJECT - 634.865kW DC STC RATING / 585.445kW AC CEC RATING Sheet # Sheet Name PV-1 Title Sheet PV-2 Notes PV-3 Site Overview PV-4 Array Layout PV-5 (E) Roof Plan PV-6 Structural Details PV-7 Wiring Layout PV-8 Wiring Layout PV-9.1 Single Line Diagram System 1 PV-9.2 Single Line Diagram System 2 PV-10 Spec Sheets PV-11 Spec Sheets PV-12 Spec Sheets PV-13 Spec Sheets PC-1 Cover Sheet PC-2 Project Summary PC-3 Array Site Map PC-4 Typical Array Dimensions PC-5 Assemblies PC-6 Racking Components PC-7 Ballast Legend PC-8 Ballast Layout 1.1 PC-9 Ballast Layout 1.2 PC-10 Ballast Layout 1.3 PC-11 Ballast Layout 1.4 PC-12 Mechanical Attachment Detail PROJECT TOTAL TOTAL SYSTEM SIZE: 634.865 kW DCstc, 480.000 kW AC INVERTER CAPACITY, 585.758 kW ACcec INTERCONNECTION 1 SYSTEM SIZE: 425.345 kW DCstc, 320.000 kW AC INVERTER CAPACITY, 392.445 kW ACcec INTERCONNECTION 2 SYSTEM SIZE: 209.52 kW DCstc, 160.000 kW AC INVERTER CAPACITY, 193.313 kW ACcec INTERCONNECTION 1: PANEL SPECS: (877) HANWHA Q CELLS, Q.PEAK DUO XL-G10.3/BFG 485 INVERTER SPECS: (2) SOLAREDGE TECHNOLOGIES, SE120KUS [480V] (1) SOLAREDGE TECHNOLOGIES, SE80KUS [480V] OPTIMIZER / RAPID SHUTDOWN SPECS: (440) SOLAREDGE PER P1101 OPTIMIZER Parcel #: 1021132040000 PROJECT LOCATION PROJECT LOCATION ARRAY LOCATION INTERCONNECTION 2: PANEL SPECS: (432) HANWHA Q CELLS, Q.PEAK DUO XL-G10.3/BFG 485 INVERTER SPECS: (2) SOLAREDGE TECHNOLOGIES, SE80KUS [480V] OPTIMIZER / RAPID SHUTDOWN SPECS: (216) SOLAREDGE PER P1101 OPTIMIZER No . De sc ri pt ion Da t e Bldg #101121774-75 Elect #20184604-05 APPROVALS: PLNG - C. Santana BLDG - T. Le PUBLIC WORKS - Y. Soto ELECT - M. Smith 1895 & 1995 S Standard Ave1/7/2025 THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 11 / 6 / 2 0 2 4 1 0 : 4 8 : 2 0 A M Ut i l i t y C u s t o m e r N a m e : P r o l o g is L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 19 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-2 No t e s SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 ABBREVIATIONS ALTERNATING CURRENT APPROXIMATE AMERICAN WIRE GUAGE CENTER LINE COMBINER BOX DIRECT CURRENT DROP INLET DISCONNECT ELECTRICAL METALLIC TUBING (EXISTING) ELEVATION EQUAL INSIDE DIAMETER JUNCTION BOX MAIN COMBINER BOX MANUFACTURER MINIMUM MISCELLANEOUS (NEW) OR APPROVED EQUAL ON CENTER OUTSIDE DIAMETER POINT OF COMMON COUPLING PHOTOVOLTAIC PROPERTY LINE STORM DRAIN SQUARE FOOT/FEET SIMILAR TO BE DETERMINED TOP OF FOOTING TYPICAL UNLESS OTHERWISE NOTED VERIFY IN FIELD TRANSFORMER NOTESSYMBOLS AC APPROX AWG CL CB DC DI DISC EMT (E) EL EQ ID JB MCB MFR MIN MISC (N) OAE OC OD POCC PV PL SD SF SIM TBD TOF TYP UON VIF XFMR No. Descrip tio n Date 1895 & 1995 S Standard Ave1/7/2025 PV-4 1 PARKING SPACE TYP DRIVEWAY (E) MAIN STRUCTURE SKYLIGHT TYP DRIVEWAY DRIVEWAY ROOF OBSTRUCTION TYP S S T A N D A R D A V E CL CL ARRAY 1 TILT: 10° AZIMUTH: 180° ARRAY 2 TILT: 10° AZIMUTH: 180° ARRAY 4 TILT: 10° AZIMUTH: 180° ARRAY 3 TILT: 10° AZIMUTH: 180° 6' FIRE ACCESS PERIMETER 6' FIRE ACCESS PERIMETER 6' FIRE ACCESS PERIMETER 6' FIRE ACCESS PERIMETER LO A D I N G D O C K S 8' FIRE ACCESS PATHWAY 8' FIRE ACCESS PATHWAY 8' FIRE ACCESS PATHWAY 8' F I R E A C C E S S P A T H W A Y PL PL PL PL ROOF LEVEL: (N) INVERTER #3 -80kW (N) INVERTER #2 -120kW (N) PV AC DISCONNECT 1 FOR 1995 S STANDARD AVE FOR UTILITY OPERATION AND RAPID SHUTDOWN INITIATION (N) INVERTER #1 -120kW (N) INVERTER #5 -80kW (N) INVERTER #4 -80kW (E) MAIN SWITCHBOARD (MS -B) OUTSIDE ELECTRICAL ROOM GROUND LEVEL: (N) PV SUB 1 (N) PV SUB 2 (E) METER AND SERVICE DISCONNECT FOR 1895 S STANDARD AVE (E) METER AND SERVICE DISCONNECT FOR 1995 S STANDARD AVE (N) PV AC DISCONNECT 2 FOR 1895 S STANDARD AVE FOR UTILITY OPERATION AND RAPID SHUTDOWN INITIATION INSIDE ELECTRICAL ROOM GROUND LEVEL: MA STRUT BOLTED CONNECTIONS (E) ROOF BUILDUP (E) ROOF SHEATHING (N) #12 x 1-1/2" SHEET METAL SCREWS INTO 1/2" ROOF SHEATHING -6 PER ATTACHMENT (N) U ANCHOR 2400/2600 SEE PANEL CLAW PLANS PC-11 FOR LOCATIONS THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 11 / 6 / 2 0 2 4 1 0 : 5 1 : 1 3 A M Ut i l i t y C u s t o m e r N a m e : P r o l o g is L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 19 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-3 Si t e O v e r v i e w SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 1" = 50'-0"1 Layout - Site Overview Array Details Array Name Tilt° Azimuth Module Count ARRAY 1 10 180 258 ARRAY 2 10 180 326 ARRAY 3 10 180 329 ARRAY 4 10 180 391 Grand total 1304 No. Description Date 3" = 1'-0"2 Attachhment Fastener Detail 1895 & 1995 S Standard Ave1/7/2025 REPRESENTATIVE CONDUCTORS CONDUIT COMPRESSION FITTING LOCK NUT ENCLOSURE WALL CONTINUOUS GROUND STRIP INSULATION AT LUG GROUND BUSHING WITH LAY-IN LUG TORQUE PER MANFACTURER'S SPECS 10-24 SS NUT /W STAR WASHER RAIL FRAME ILSCO #4 LAY IN LUG TINNED STAR WASHER LUGS SUBJECT TO THE ENVIRONMENT SHALL BE OUTDOOR RATED. 6' FIRE ACCESS PERIMETER 88 ' - 2 " 14 6 ' - 4 " 24 ' - 4 " 12 3 ' - 6 " ARRAY 1 TILT: 10° AZIMUTH: 180° ARRAY 2 TILT: 10° AZIMUTH: 180° ARRAY 4 TILT: 10° AZIMUTH: 180° ARRAY 3 TILT: 10° AZIMUTH: 180° 8' FIRE ACCESS PATHWAY 8' FIRE ACCESS PATHWAY 8' FIRE ACCESS PATHWAY PV-7 1 PV-7 2 PV-8 3 PV-8 2 INTEROW SPACING 1' - 1" 63 6 ' - 7" 12' - 4"116' - 8"20' - 8"123' - 10"17' - 4" 290' - 10" ROOF LEVEL: (N) INVERTER #3 -80kW (N) INVERTER #2 -120kW (N) PV AC DISCONNECT 1 FOR 1995 S STANDARD AVE FOR UTILITY OPERATION AND RAPID SHUTDOWN INITIATION (N) INVERTER #1 -120kW (N) INVERTER #5 -80kW (N) INVERTER #4 -80kW (E) MAIN SWITCHBOARD (MS -B) OUTSIDE ELECTRICAL ROOM GROUND LEVEL: PROPOSED COMMUNICATION CABLES RUN (ACTUAL LOCATION TO BE DETERMINED ON SITE) (N) PV SUB 1 (N) PV SUB 2 (E) METER AND SERVICE DISCONNECT FOR 1895 S STANDARD AVE (E) METER AND SERVICE DISCONNECT FOR 1995 S STANDARD AVE (N) PV AC DISCONNECT 2 FOR 1895 S STANDARD AVE FOR UTILITY OPERATION AND RAPID SHUTDOWN INITIATION INSIDE ELECTRICAL ROOM GROUND LEVEL: 0' - 4"0' - 4" (N) SOLAR PV COMBINER (N) CONDUIT PER PV-5 (SUPPORT EVERY 10FT MAX) 1' - 0" MIN FLASHING PIPE SEAL SS HOSE CLAMP ROOF DECK CONDUIT SECURING WITHIN 1FT OF PENETRATION MIN 0' - 8" JUNCTION BOX CONDUIT PYRAMID BLOCK ROOF DECK ROOFING ROOF FRAMING BEYOND FASTENED AT LEAST EVERY (10'-0")OR OTHER TUBING TERMINATION FASTENED (3'-0") FROM JUNCTION BOX, COMIBNER PYRAMID BLOCK (3 . 5 " ) Expansion Calculation: All Lengths Over: 736.8 in (61.4FT) Require an Expansion fitting Max temp delta: 31°C or 87.8°F, Min Temp: 2°C or 35.6°F 0.00000650 in/in°F x (87.8-35.6)°F x 736.8 in (61.4FT) = 0.25" XJG104 EMT expansion fitting can compensate for a 4" of movement therefore 1 expansion joint for this run is ok Max Length of Run for a single expansion joint: 11,788.9 in (982.4FT) Max temp delta: 31°C or 87.8°F, Min Temp: 2°C or 35.6°F 0.00000650 in/in°F x (87.8-35.6°F x 11,788.9 in (982.4FT) = 4" XJG104 EMT expansion fitting can compensate for a 4" of movement therefore 1 expansion joint for this run is ok (N) CONDUIT PER PV-10 (SUPPORT EVERY 10FT MAX) 1' - 0" MIN FLASHING PIPE SEAL SS HOSE CLAMP ROOF DECK CONDUIT SECURING WITHIN 1FT OF PENETRATION MIN 0' - 8" 3FT MAXCONDUIT SUPPORT (N) CONDUIT SWEEP TYP THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 11 / 6 / 2 0 2 4 1 0 : 4 8 : 2 2 A M Ut i l i t y C u s t o m e r N a m e : P r o l o g is L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 19 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-4 Ar r a y L a y o u t SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 Array Details Array Name Tilt° Azimuth Module Count ARRAY 1 10 180 258 ARRAY 2 10 180 326 ARRAY 3 10 180 329 ARRAY 4 10 180 391 Grand total 1304 6" = 1'-0"3 Detail Grounding Conduit Body 6" = 1'-0"2 Detail Grounding Lay-in Lug 1" = 20'-0"1 Layout - Site Overview - Array 1" = 1'-0"6 Conduit Penetration - Option 1 1/2" = 1'-0"4 Detail Conduit Runs on Roof1 1" = 1'-0"7 Conduit Penetration - Option 3 No. Description Date 1895 & 1995 S Standard Ave1/7/2025 PV-5 2 COLUMN 4' GIRDERS 8' OC PURLINS 24" -36" SUB PURLINS 2"X4" 24" O.C SKYLIGHT TYP52' - 0" 50' - 0" THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 11 / 6 / 2 0 2 4 1 0 : 4 8 : 2 6 A M Ut i l i t y C u s t o m e r N a m e : P r o l og i s L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 19 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-5 (E ) R o o f P l a n SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 PROPOSED PV LOCATION 1" = 50'-0"1 Layout - Roof Framing 1" = 10'-0"2 Layout - Roof Framing - Callout 1 No. Description Date 1895 & 1995 S Standard Ave1/7/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SETRACKING CONSTRUCTION SET GENERAL NOTES: 1.ALL SITE, PROJECT, AND BUILDING DETAILS ARE PROVIDED BY CUSTOMER OR GENERATED VIA SATELLITE IMAGERY FROM INFORMATION PROVIDED BY CUSTOMER. PANELCLAW IS NOT RESPONSIBLE FOR SITE INACCURACIES THAT COULD LEAD TO CHANGES TO THESE DRAWING DETAILS AND ARRAY LAYOUT CONFIGURATIONS. ALL INFORMATION CONTAINED WITHIN THESE DOCUMENTS ARE TO BE FIELD VERIFIED BY CUSTOMER AND INSTALLER. ANY CHANGES OR MODIFICATIONS TO THESE DOCUMENTS, CONTAINED INFORMATION, OR FINAL ARRAY AND MOUNTING SYSTEM INSTALLATIONS MUST BE SUBMITTED TO PANELCLAW AND OTHER PROJECT AUTHORITIES FOR APPROVAL. 2.REFER TO AND FOLLOW THE APPROPRIATE PANELCLAW INSTALLATION MANUALS AND PROCEDURES DURING THE INSTALLATION PROCESS. NOT FOLLOWING SUCH PROCEDURES AND METHODS COULD RESULT IN DAMAGE TO THE COMPONENTS OR MAY VOID THE PRODUCT WARRANTY. 3.ARRAY SETBACKS: ALL ARRAYS ARE REQUIRED TO BE SETBACK 4-FEET FROM ALL ROOF EDGES UNLESS OTHERWISE SPECIFIED AND CALLED OUT ON THE ARRAY DIAGRAMS ON THIS PAGE OR ON ADDITIONAL ARRAY BALLAST PAGES 4.REFER TO THE SPECIFIC ARRAY BALLAST SHEETS FOR BALLASTING REQUIREMENTS BASED ON THE PROVIDED SITE INFORMATION 5.SYSTEM PSF INCLUDES ALL PANELCLAW RACKING COMPONENTS, MECHANICAL ATTACHMENTS (IF APPLICABLE), PV MODULE AND BALLAST BLOCKS. FOR MAXIMUM SYSTEM POINT LOAD SUMMARY (PLS), REFER TO CALCULATIONS. 6.PANELCLAW AND/OR PANELCLAW CONSULTING ENGINEERS ARE NOT RESPONSIBLE FOR DETERMINING THE ADEQUACY OF THE STRUCTURE TO SUPPORT LOADS IMPOSED BY THE ARRAY AND MOUNTING SYSTEM. SUPPORT STRUCTURE TO BE CHECKED BY OTHERS 7.ALWAYS ALLOW 6” CLEARANCE BETWEEN NEIGHBORING SUBARRAYS, 6” BETWEEN SUBARRAYS AND ALL FIXED ROOF OBJECTS AND 4' BETWEEN SUBARRAYS AND ROOF EDGES. REFER TO LOCAL FIRE CODES AND ELECTRICAL CODES FOR ADDITIONAL REQUIREMENTS WHICH MAY GOVERN DESIGN. SUBARRAYS THAT USE A SEISMIC ANALYSIS METHOD OF DELTA MPV PER SEAOC OR ASCE 7-16 HAVE THEIR OWN CLEARANCE REQUIREMENTS. REFER TO THE BALLAST LAYOUT SHEETS WITHIN THIS DOCUMENT FOR DETAILS. 8.BALLAST BLOCK DIMENSIONS MUST CONFORM TO THE FOLLOWING SPECIFICATIONS: 3-3/4” THICK MAX., 7-5/8” ± 1/8” WIDTH, 15-5/8” ± 1/8” LENGTH. 9.IF AN ARRAY CLEARANCES TABLE APPEARS BELOW ON THIS PAGE, THE DESIGN UTILIZES THIRD PARTY SEISMIC NON-LINEAR RESPONSE ANALYSIS TO ESTIMATE MAXIMUM ARRAY SEISMIC DISPLACEMENT. THE PREDICTED MOVEMENT IS ONLY AN ESTIMATE. PANELCLAW IS NOT RESPONSIBLE OR LIABLE FOR ANY DAMAGES OR COSTS ASSOCIATED WITH PV ARRAY MOVEMENT INCLUDING MOVEMENT IN EXCESS OF THE CLEARANCES NOTED IN THIS DOCUMENT OR ANY REQUIREMENT TO REPOSITION THE ARRAYS IF MOVEMENT OCCURS. 10.DEFLECTORS MUST BE INSTALLED WHEN WINDS ARE EXPECTED TO EXCEED APPROX. 25% OF WIND SPEED DOCUMENTED IN SITE DESIGN CRITERIA TABLE. DEFLECTORS ARE REQUIRED ON ALL MODULES UNLESS OTHERWISE NOTED ON BALLAST LAYOUT PAGES. SHEET INDEX NO.DESCRIPTION PC-1 COVER SHEET PC-2 PROJECT SUMMARY PC-3 ARRAY SITE MAP PC-4 TYPICAL ARRAY DIMENSIONS PC-5 ASSEMBLIES PC-6 RACKING COMPONENTS PC-7 BALLAST LEGEND PC-8 TO PC-11 BALLAST LAYOUT - 1 TO 4 PC-12 MECHANICAL ATTACHMENT DETAIL Site Design Criteria - Flat Roof PV System Basis of Design Roof Live Load (psf)20(see footnote 1) Ground Snow Pg (psf)0 Flat Roof Snow Pf (psf)0 Snow Importance Factor (Is)1.0 Wind Design Data Basic Wind Speed (mph)95 Risk Category II Wind Exposure B Earthquake Design Data Risk Category II Importance Factor (Ie)1.00 Component Importance Factor (Ip)1.0 Mapped Acceleration Parameter (Ss)1.276 Mapped Acceleration Parameter(S1)0.456 Seismic Site Class D Design Spectral Acceleration Parameter (Sds)1.021 Design Spectral Acceleration Parameter (Sd1)0.561 Seismic Design Category (SDC)D Basic seismic-force-resisting system(s)roof anchors Base Design Shear = Fp x W 0.49 W Response Modification Factor (R)2.5 Analysis Procedure ASCE 7 sec. 13.3/4 Design Code (with local amendments)2022 CBC -ASCE 7 - 16 ALTERNATE DESIGN METHOD -SEAOC PV2 1. Roof Live Load only applicable to areas not covered by PV modules. Reference SEAOC Design Guidelines AERIAL PHOTO / SITE DIAGRAM THIS CONSTRUCTION SET PROVIDES THE RACKING LAYOUT FOR ALL ARRAYS WITH NUMBER OF BALLAST BLOCKS AND/OR MECHANICAL ATTACHMENTS BASED ON THE APPROVED STRUCTURAL CALCULATIONS FOR THE COMPLETED INSTALLED CONDITION OF THE SOLAR ARRAY. THE INSTALLER IS RESPONSIBLE FOR THE SAFETY AND CARE OF THE ARRAY DURING ALL PHASES OF INSTALLATION. THEREFORE, THE INSTALLER MUST MONITOR THE WEATHER FORECAST AND TAKE NECESSARY PRECAUTIONS (SEE GENERAL NOTE #10) TO TEMPORARILY SHORE/BRACE ALL ARRAYS DURING CONSTRUCTION UNTIL INSTALLATION IS COMPLETED IN CONFORMANCE WITH THIS APPROVED CONSTRUCTION SET AND THE PRODUCT INSTALLATION MANUAL (SEE GENERAL NOTE #2). THE INSTALLER HAS SOLE RESPONSIBILITY FOR THE MEANS, METHODS, AND TECHNIQUES OF CONSTRUCTION OF THE SOLAR ARRAY FOR COMPLIANCE WITH LAWS, REGULATIONS, AND CODES, AND FOR THE SAFETY OF CONSTRUCTION APPLICABLE TO THIS WORK. APPROVED FOR CONSTRUCTION Axis Solar Santa Ana Dist Ctrl 1 1895 S Standard Ave, Santa Ana, CA 92707, USA COVER SHEET PC-11 24.05.14.1 v3.0.9405.5.2 1 Re v i s e d B a l l a s t RH 20 2 4 - 0 5 - 2 4 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 5 - 0 9 TROY E.TURLEY 6/5/2024 24-0242-3039.1 1895 & 1995 S Standard Ave1/7/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.3 ROOF INFORMATION ROOF HEIGHT (FT)36.00 PARAPET HEIGHT (FT) 5.0 ROOF TILT (DEG) 1 ROOF TYPE TPO SPECIFICATIONS NUMBER OF MODULES 396 MODULE POWER (W) 485 ARRAY OUTPUT (Kw) 192.06 ARRAY AZIMUTH 181 PART QUANTITIES ITEM QTY Base 898 Module Connector 792 Rail 981 Cam 792 Cam Claw 792 Deflector 396 Base Pad 0 Ballast Block 128 Mechanical Attachment 20 LOADING DETAILS SINGLE MODULE WT (LB) 64.2 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 36075 ARRAY AREA (SQ. FT)12994 ARRAY LOAD (PSF) 2.78 APPROVED FOR CONSTRUCTION Axis Solar Santa Ana Dist Ctrl 1 1895 S Standard Ave, Santa Ana, CA 92707, USA BALLAST LAYOUT - 1.3 PC-101 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.3 PC-10 1 Re v i s e d B a l l a s t RH 20 2 4 - 0 5 - 2 4 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 5 - 0 9 1/12" = 1'-0" 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 11 1 1 139.70' 131.87' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 106 SOUTH ASSEMBLY 106 MIDDLE ASSEMBLY 580 NORTH SOUTH ASSEMBLY 0 TROY E.TURLEY 6/5/2024 24-0242-3039.1 1895 & 1995 S Standard Ave1/7/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.4 ROOF INFORMATION ROOF HEIGHT (FT)36.00 PARAPET HEIGHT (FT) 5.0 ROOF TILT (DEG) 1 ROOF TYPE TPO SPECIFICATIONS NUMBER OF MODULES 326 MODULE POWER (W) 485 ARRAY OUTPUT (Kw) 158.11 ARRAY AZIMUTH 181 PART QUANTITIES ITEM QTY Base 754 Module Connector 652 Rail 825 Cam 652 Cam Claw 652 Deflector 326 Base Pad 0 Ballast Block 113 Mechanical Attachment 16 LOADING DETAILS SINGLE MODULE WT (LB) 64.2 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 29997 ARRAY AREA (SQ. FT)10681 ARRAY LOAD (PSF) 2.81 APPROVED FOR CONSTRUCTION Axis Solar Santa Ana Dist Ctrl 1 1895 S Standard Ave, Santa Ana, CA 92707, USA BALLAST LAYOUT - 1.4 PC-111 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.4 PC-11 1 Re v i s e d B a l l a s t RH 20 2 4 - 0 5 - 2 4 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 5 - 0 9 1/12" = 1'-0" 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 121.64' 124.54' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 102 SOUTH ASSEMBLY 102 MIDDLE ASSEMBLY 448 NORTH SOUTH ASSEMBLY 0 TROY E.TURLEY 6/5/2024 24-0242-3039.1 1895 & 1995 S Standard Ave1/7/2025 U-ANCHOR 2400 MECHANICAL ATTACHMENT ø 6.4 mm (0.25 in) MECHANICAL ATTACHMENT WORST-CASE SERVICE LOAD (LB) HORIZONTAL (H)VERTICAL (V) WIND SEISMIC WIND MAXIMUM ALLOWABLE LOAD (LB) HORIZONTAL (H)VERTICAL (V) RACKING CONSTRUCTION SET Axis Solar Santa Ana Dist Ctrl 1 1895 S Standard Ave, Santa Ana, CA 92707, USA 1 PC-12 MECHANICAL ATTACHMENT DETAIL 24.05.14.1 v3.0.9405.5.2 1 Re v i s e d B a l l a s t RH 20 2 4 - 0 5 - 2 4 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 5 - 0 9 0 644 0 650 525 APPROVED FOR CONSTRUCTION PC-12 PC-12 PC-12 TROY E.TURLEY 6/5/2024 24-0242-3039.1 1895 & 1995 S Standard Ave1/7/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: SITE MAP A PC-2NTS RACKING CONSTRUCTION SET Axis Solar Santa Ana Dist Ctrl 1 1895 S Standard Ave, Santa Ana, CA 92707, USA PROJECT SUMMARY PC-21 24.05.14.1 v3.0.9405.5.2 clawFRplus 10 Degree - 35 cm PROJECT PART QUANTITY ITEM PART NUMBER QTY Base 500050203 3058 BASE, 03, CFR Module Connector 500063302 2618 MODULE CONNECTOR, 1070, 10D, CFRP Rail 2000895 3377 RAIL, 2500, CFR Cam 5000630 2618 CAM, 10D, CFRP Cam Claw 2000854 2618 CAM CLAW, CFRP Deflector 200088705 1309 DEFLECTOR, 10D, 2300, CFR Bolt 2000697 12624 BLT, HEX FLG, TRI, M6X16, GR8.8, PATCH Base Pad 2000678 0 PAD, BASE, CFR CONCRETE MASONRY UNIT N/A 486 BLOCK, CONCRETE, 32.6 LB, - Xin x 8in x 16in NOMINAL, PARTNER SUPPLIED, SEE INSTALLATION MANUAL APPROVED FOR CONSTRUCTION MECHANICAL ATTACHMENT PART QUANTITY MA Hardware Kit 5000423 7 HW KIT, MA STRUT, 2500, CFR MA Strut 2000930 67 MA STRUT, 2500, CFR Mechanical Attachment 100035908 67 MA, ANCH 2400, JMAN TPO TOTAL MECHANICAL ATTACHMENT COUNT 67 PROJECT SUMMARY MODULE TYPE HANWHA Q CELLS Q.PEAK DUO XL- G10.3/BFG 485 MODULE DIMENSIONS (IN.)87.24 X 41.14 X 1.38 NUMBER OF MODULES 1309 MODULE WATTAGE (W STC)485 SYSTEM SIZE (kW STC)634.865 SYSTEM WEIGHT (LB)121693 SYSTEM AREA (SQ FT.)42856 AGGREGATE SYSTEM LOAD (PSF)2.84 NUMBER OF ARRAYS 4 ARRAY TILT (DEG)9.76 1 Re v i s e d B a l l a s t RH 20 2 4 - 0 5 - 2 4 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 5 - 0 9 Roof 1 TROY E.TURLEY 6/5/2024 24-0242-3039.1 1895 & 1995 S Standard Ave1/7/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: # RACKING CONSTRUCTION SET NOTES: 1.ALL DIMENSIONS SHOWN ARE BASED UPON INFORMATION PROVIDED TO PANELCLAW. FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION OF THE SOLAR ARRAY. NOTIFY PANELCLAW OF ANY DISCREPANCIES. APPROVED FOR CONSTRUCTION Axis Solar Santa Ana Dist Ctrl 1 1895 S Standard Ave, Santa Ana, CA 92707, USA ARRAY SITE MAP PC-31 24.05.14.1 v3.0.9405.5.2 ROOF NAME ROOF SETBACK (FT.) ROOF HEIGHT (FT) PARAPET HEIGHT (FT) ROOF TILT (DEG) Roof 1 6.00 36.00 5.0 1 KEEPOUT NAME KEEPOUT CLEARANCE (FT.) KEEPOUT HEIGHT (IN.) Group 1 4 48 Group 2 4 84 Group 3 4 24 3 1 Re v i s e d B a l l a s t RH 20 2 4 - 0 5 - 2 4 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 5 - 0 9 22'3'26'2'237' 1016' 237'2'25'2'22'20' 2' 21' 4' 52' 1' 829' 1' 52' 4'14'2' 28' 1 2 3 4 TROY E.TURLEY 6/5/2024 24-0242-3039.1 1895 & 1995 S Standard Ave1/7/2025 'L' RAIL INSTALLATION: USE THE OUTER SET OF HOLES WHEN INSTALLING RAILS BETWEEN MODULES. RAIL ON “L” SPACING IS ALWAYS ON TOP OF RAIL ON “S” SPACING. THIS INSTALLATION SEQUENCE IS CRITICAL TO SYSTEM PERFORMANCE. FOR MORE INFORMATION REVIEW THE INSTALLATION MANUAL AND VIDEOS. RAIL DETAIL C NTS RACKING CONSTRUCTION SET Axis Solar Santa Ana Dist Ctrl 1 1895 S Standard Ave, Santa Ana, CA 92707, USA 1 24.05.14.1 v3.0.9405.5.2 INSTALLED ARRAY DIMENSIONS A B C D G J K M N O P R W X Theta (DEG)D/J (#:1)G.C.R.* mm 2234 1376 121 347 116 177 209 1030 81 59 92 516 321 137 9.76 1.96 0.76UNITS inches 87.95 54.19 4.75 13.65 4.56 6.97 8.23 40.55 3.20 2.31 3.61 20 5/16 12.64 5.39 9.76 1.96 0.76 * G.C.R = (PW) / B INSTALLATION MEASUREMENTS AEBE S L CAM SPACING* mm 486 1184 1050 46UNITS inches 19 1/8 46 5/8 41 5/16 1 13/16 *CAM SPACING SHOWN ON ASSEMBLIES PAGE. MODULE DIMENSIONS PL PW PT mm 2216 1045 35UNITS inches 87.24 41.14 1.38 PC-4 PC-4 PC-4 TYPICAL ARRAY DIMENSIONS PC-4 APPROVED FOR CONSTRUCTION 1 Re v i s e d B a l l a s t RH 20 2 4 - 0 5 - 2 4 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 5 - 0 9 TROY E.TURLEY 6/5/2024 24-0242-3039.1 1895 & 1995 S Standard Ave1/7/2025 BASE HOLE "2" BASE HOLE "1" BASE HOLE "1" BASE HOLE "2" BASE HOLE "3" BASE HOLE "3" BASE HOLE "1"BASE HOLE "2"BASE HOLE "1"BASE HOLE "2"BASE HOLE "1"BASE HOLE "2"BASE HOLE "3"BASE HOLE "2" ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: EXAMPLE ARRAY CONSTRUCTION F NTS RACKING CONSTRUCTION SET Axis Solar Santa Ana Dist Ctrl 1 1895 S Standard Ave, Santa Ana, CA 92707, USA ASSEMBLIES PC-51 24.05.14.1 v3.0.9405.5.2 APPROVED FOR CONSTRUCTION PC-5 PC-5 PC-5 PC-5 PC-5 PC-5 STANDARD ASSEMBLY QUANTITY NORTH ASSEMBLY 438 SOUTH ASSEMBLY 438 MIDDLE ASSEMBLY 1740 NORTH SOUTH ASSEMBLY 2 NOTE: ASSEMBLIES IN THIS TABLE USE THE STANDARD 2-PAD BASE CAM SPACING mm 46UNITS inches 1 13/16 TROY E.TURLEY 6/5/2024 24-0242-3039.1 1895 & 1995 S Standard Ave1/7/2025 NOTE: EXAMPLE BALLASTING SHOWN ON THIS PAGE IS FOR REFERENCE ONLY AND DO NOT REFLECT TYPICAL BALLAST PLACEMENT. REFER TO BALLAST MAP SHEETS FOR ARRAY SPECIFIC BALLAST REQUIREMENTS. BASE RAIL DEFLECTOR CAM BRACKET AND CAM CLAW TRANSPARENT MODULE MODULE CONNECTOR RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: EXAMPLE RAIL AND BLOCK CONFIGURATION A NTS RACKING CONSTRUCTION SET Axis Solar Santa Ana Dist Ctrl 1 1895 S Standard Ave, Santa Ana, CA 92707, USA 1 APPROVED FOR CONSTRUCTION PC-6 RACKING COMPONENTS 24.05.14.1 v3.0.9405.5.2 PC-6 PC-6 PC-6 PC-6 PC-6 PC-6PC-6 1 Re v i s e d B a l l a s t RH 20 2 4 - 0 5 - 2 4 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 5 - 0 9 TROY E.TURLEY 6/5/2024 24-0242-3039.1 1895 & 1995 S Standard Ave1/7/2025 MECHANICAL ATTACHMENT AT INDICATED LOCATION NOTE: EXAMPLE BALLAST AND ATTACHMENTS SHOWN ON THIS PAGE ARE FOR REFERENCE ONLY. REFER TO BALLAST MAP SHEETS FOR ARRAY SPECIFIC BALLAST/ATTACHMENT REQUIREMENTS. BALLAST QUANTITY: "#"=QUANTITY OF BALLAST BLOCK INSTALLEDCENTERED UNDER MODULE IF NO BALLAST QUANTITY SHOWN, DO NOT PLACE BALLAST SEE INSTALLATION MANUAL FOR NOTES ON INSTALLING MORE THAN FOUR BALLAST BLOCKS PER MODULE DO NOT INSTALL ADDITIONAL RAIL TO HOLDBALLAST ON MODULES WITH NO BALLASTSHOWN. MODULES LONGER THAN 2100 MM WITH 7 OR 8 BALLAST BLOCKS REQUIRE TWO (2) RAILS. ARRAY CROSS SECTION VIEW A NTS RACKING CONSTRUCTION SET Axis Solar Santa Ana Dist Ctrl 1 1895 S Standard Ave, Santa Ana, CA 92707, USA 1 PC-7 BALLAST LEGEND APPROVED FOR CONSTRUCTION 24.05.14.1 v3.0.9405.5.2 PC-7 PC-7 1 Re v i s e d B a l l a s t RH 20 2 4 - 0 5 - 2 4 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 5 - 0 9 TROY E.TURLEY 6/5/2024 24-0242-3039.1 1895 & 1995 S Standard Ave1/7/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.1 ROOF INFORMATION ROOF HEIGHT (FT)36.00 PARAPET HEIGHT (FT) 5.0 ROOF TILT (DEG) 1 ROOF TYPE TPO SPECIFICATIONS NUMBER OF MODULES 329 MODULE POWER (W) 485 ARRAY OUTPUT (Kw) 159.565 ARRAY AZIMUTH 181 PART QUANTITIES ITEM QTY Base 774 Module Connector 658 Rail 864 Cam 658 Cam Claw 658 Deflector 329 Base Pad 0 Ballast Block 136 Mechanical Attachment 17 LOADING DETAILS SINGLE MODULE WT (LB) 64.2 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 31077 ARRAY AREA (SQ. FT)10765 ARRAY LOAD (PSF) 2.89 APPROVED FOR CONSTRUCTION Axis Solar Santa Ana Dist Ctrl 1 1895 S Standard Ave, Santa Ana, CA 92707, USA BALLAST LAYOUT - 1.1 PC-81 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.1 PC-8 1 Re v i s e d B a l l a s t RH 20 2 4 - 0 5 - 2 4 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 5 - 0 9 1/12" = 1'-0" 1 1 1 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 144.22' 117.21' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 114 SOUTH ASSEMBLY 114 MIDDLE ASSEMBLY 428 NORTH SOUTH ASSEMBLY 2 TROY E.TURLEY 6/5/2024 24-0242-3039.1 1895 & 1995 S Standard Ave1/7/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.2 ROOF INFORMATION ROOF HEIGHT (FT)36.00 PARAPET HEIGHT (FT) 5.0 ROOF TILT (DEG) 1 ROOF TYPE TPO SPECIFICATIONS NUMBER OF MODULES 258 MODULE POWER (W) 485 ARRAY OUTPUT (Kw) 125.13 ARRAY AZIMUTH 181 PART QUANTITIES ITEM QTY Base 632 Module Connector 516 Rail 707 Cam 516 Cam Claw 516 Deflector 258 Base Pad 0 Ballast Block 109 Mechanical Attachment 14 LOADING DETAILS SINGLE MODULE WT (LB) 64.2 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 24544 ARRAY AREA (SQ. FT)8415 ARRAY LOAD (PSF) 2.92 APPROVED FOR CONSTRUCTION Axis Solar Santa Ana Dist Ctrl 1 1895 S Standard Ave, Santa Ana, CA 92707, USA BALLAST LAYOUT - 1.2 PC-91 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.2 PC-9 1 Re v i s e d B a l l a s t RH 20 2 4 - 0 5 - 2 4 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 5 - 0 9 1/12" = 1'-0" 1 1111111 1 1 1 1 1 1 1 1 1 11 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 112.61' 117.21' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 116 SOUTH ASSEMBLY 116 MIDDLE ASSEMBLY 284 NORTH SOUTH ASSEMBLY 0 TROY E.TURLEY 6/5/2024 24-0242-3039.1 1895 & 1995 S Standard Ave1/7/2025 6"X8" TYP -CEC 705.10 12 NOTES 1. ARTICLES 690 AND 705 MARKINGS SHOWN HEREON 2. ALL MARKINGS SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING B. RED BACKGROUND COLOR WITH WHITE TEXT AND LINE WORK UON C. ARIAL FONT 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT USING PERMANENT ADHESIVE, POP-RIVETS, OR SCREWS M JBOX OR COMBINER AC DISCONNECT INVERTER WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! ORANGE WARNING AREA, 690.13(B) WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! ORANGE WARNING AREA, 690.13(B) DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT PHOTOVOLTAIC 690.13(B) DC DISCONNECT WARNING: PHOTOVOLTAIC POWER SOURCE REFLECTIVE STICKER, 690.31(G)(3)(4) WARNING! DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM ORANGE WARNING AREA, 705.12(B)(3) ARRAY DC DISCONNECT 1 3 4 6 7 2 6 54 11 1 10 12 7 3 SOLAR SUB PANEL7 2 21 6 MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) 690.53 5 1000V 18A 18A SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY The title “SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN” shall utilize capitalized characters with a minimum height of 9.5 mm (3⁄8 in.) in black on yellow background and the remaining characters shall be capitalized with a minimum height of 4.8 mm (3⁄16 in.) in black on white background. 690.56(C)(1)(a) PV10 PHOTOVOLTAIC AC DISCONNECT 690.13(B), 690.54 RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE 8 480V 385.1A RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM REFLECTIVE STICKER, 690.56(C)(3) 11 1 8 PHOTOVOLTAIC AC DISCONNECT 690.13(B), 690.54 RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE 8 480V 193A INTERCONNECTION 1:INTERCONNECTION 2: WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE SWITCHBOARD ! ORANGE WARNING AREA, 110.27(C) 2 WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL ! ORANGE WARNING AREA, 110.27(C) 2 FOR SUBPANEL/ COMBINER PV DISCONNECT 690.13(B), 690.54 RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE 8c 480V 96.5A 80K INVERTER PV DISCONNECT 690.13(B), 690.54 RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE 8b 480V 144.3A 120K INVERTER CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS SHOWN, DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES. INTERCONNECTION 1 & 2 MAIN SERVICE PANEL FOR UTILITY METERING & SERVICE DISCONNECTS PV DISCONNECT FOR UTILITY OPERATION & RAPID SHUTDOWN (2 OF 2) INSIDE ELECTRICAL ROOM: N ROOTOP LEVEL (2) SOLAR ONLY SUBPANELS (5) INVERTERS PV DISCONNECT FOR UTILITY OPERATION & RAPID SHUTDOWN (1 OF 2) HIGHLIGHTED MODULES WILL SHUT DOWN WHEN AC DISCONNECT 1 IS IN OPEN POSTION HIGHLIGHTED MODULES WILL SHUT DOWN WHEN AC DISCONNECT 2 IS IN OPEN POSTION OUTSIDE ELECTRICAL ROOM: S S T A N D A R D A V E THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 11 / 6 / 2 0 2 4 1 0 : 4 8 : 3 2 A M Ut i l i t y C u s t o m e r N a m e : P r o l o g is L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 19 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-10 Sp e c S h e e t s SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 12" = 1'-0"1 Signage 1 12" = 1'-0"2 Spec Sheet Module 12" = 1'-0"3 Spec Sheet Panel Claw Wire Mgmt No. Descrip tio n Date 1895 & 1995 S Standard Ave1/7/2025 THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 11 / 6 / 2 0 2 4 1 0 : 4 8 : 3 9 A M Ut i l i t y C u s t o m e r N a m e : P r o l o g is L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 19 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-11 Sp e c S h e e t s SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 12" = 1'-0"1 Spec Sheet Optimizer 12" = 1'-0"3 Spec Sheet Inverter No. Descrip tio n Date 1895 & 1995 S Standard Ave1/7/2025 THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 11 / 6 / 2 0 2 4 1 0 : 4 8 : 4 3 A M Ut i l i t y C u s t o m e r N a m e : P r o l o g is L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 19 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-12 Sp e c S h e e t s SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 12" = 1'-0"1 Spec Sheet Panel Claw Racking No. Description Date 1895 & 1995 S Standard Ave1/7/2025 THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 11 / 6 / 2 0 2 4 1 0 : 4 8 : 4 4 A M Ut i l i t y C u s t o m e r N a m e : P r o l o g is L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 19 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-13 Sp e c S h e e t s SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 12" = 1'-0"1 Spec Sheet CTs2 No. Descrip tio n Date 1895 & 1995 S Standard Ave1/7/2025 8' - 0"8' - 0"8' - 0" PV SUB 1 COMBINER PANEL 300LB TYP 4' - 0" INVERTER #3 180lbs TYP INVERTER #2 251lbs TYP MIN. CLR. 3' - 2" INVERTER #1 251lbs TYP INVERTER #4 180lbs TYP INVERTER #5 180lbs TYP (2) 1/4" LAG SCREW W/ 3-1/8" MIN EFFECTIVE EMBED INTO (E) FRAMING 7 PV-6 PV SUB 2 COMBINER PANEL 150LB TYP PS 200 STRUT 7 PV-6 5' - 8 " TYP 8' - 0" 1-5/8" x 1-5/8" x12GA. POWER STRUT PS 200 2T3 HORIZ. TYP. POWER STRUT PS735 DOUBLE STRUT HORIZ TYP (E) 2X FRAMING AT INVERTER RACK 1 (AS REQUIRED) PS 200 VERT PV SUB 1 COMBINER PANEL 300LB TYP INVERTER #3 180lbs TYP INVERTER #2 251lbs TYP INVERTER #1 251lbs TYP INVERTER #4 180lbs TYP INVERTER #5 180lbs TYP PV SUB 2 COMBINER PANEL 150LB TYP 5' - 8" PV-6 8 2' - 6" 45.0° 3/8" DIA. ASTM A307 THRU BOLT W/NUT & WASHER, TYP.PS 200 W/ ADJ. PS 200 SEE DET. 3 FOR MORE INFO. (2) 1/4" LAG SCREW W/ 3-1/8" MIN EFFECTIVE EMBED PS 200 PS 7781 W/(4) 3/8" ASTM A307 THRU BOLTS (E) 2x FRAMING POWER STRUT PS735 HORIZ TYP PS 200 2T3 PS 7781 W/(4) 3/8" ASTM A307 THRU BOLTS PS 607 W/(4) 3/8" ASTM A307 THRU BOLTS PS 135 ROD COUPLING PS 146 3/8" THREADED ROD 8' - 0" PYRAMID BLOCK SUPPORT 2' - 0" 3 PV-6 INVERTER'S WT=251 LBS EA INVERTER MOUNTING PLATE INVERTER'S WT=180 LBS EA (2) 1/4" LAG SCREW W/ 3-1/8" MIN EFFECTIVE EMBED PS 200 PS 7781 W/(4) 3/8" ASTM A307 THRU BOLTS (E) 2x FRAMING PS 200 2T3 PS 135 ROD COUPLING PS 146 3/8" THREADED ROD ANCHOR PRODUCTS ANCHOR W/ TPO FLASHING TO MATCH (E) ROOF (E) ROOF DECK PYRAMID BLOCK SUPPORT W/ CHANNEL NUT 3/8" NUT TO LOCK COUPLING 3/8" NUT, LOCK WASHER & FENDER WASHER (TYP) 3/8" NUT TO LOCK COUPLING 1' - 0" THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 11 / 6 / 2 0 2 4 1 0 : 4 8 : 2 6 A M Ut i l i t y C u s t o m e r N a m e : P r o l o g is L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 19 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-6 St r u c t u r a l D e t a i l s SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 3/4" = 1'-0"1 Equipment Attachment - Plan View 3/4" = 1'-0"3 Equipment Attachment - Elevation 3/4" = 1'-0"7 Equipment Attachment - Section (Inverter Only) 3" = 1'-0"8 Equipment Attachment - Vert Support No. Description Date 1895 & 1995 S Standard Ave1/7/2025 ARRAY 1 T:10° Az: 180° ARRAY 2 T:10° Az: 180° THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 11 / 6 / 2 0 2 4 1 0 : 4 8 : 2 8 A M Ut i l i t y C u s t o m e r N a m e : P r o l o g is L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 19 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-7 W i r i n g L a y o u t SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 1" = 10'-0"1 Array 1 Wiring Array Details Array Name Tilt° Azimuth Module Count ARRAY 1 10 180 258 ARRAY 2 10 180 326 ARRAY 3 10 180 329 ARRAY 4 10 180 391 Grand total 1304 1" = 10'-0"2 Array 2 Wiring No. Descrip tio n Date 1895 & 1995 S Standard Ave1/7/2025 ARRAY 4 T:10° Az: 180° ARRAY 3 T:10° Az: 180° THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 11 / 6 / 2 0 2 4 1 0 : 4 8 : 2 8 A M Ut i l i t y C u s t o m e r N a m e : P r o l o g is L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 19 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-8 W i r i n g L a y o u t SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 Array Details Array Name Tilt° Azimuth Module Count ARRAY 1 10 180 258 ARRAY 2 10 180 326 ARRAY 3 10 180 329 ARRAY 4 10 180 391 Grand total 1304 1" = 10'-0"2 Array 4 Wiring 1" = 10'-0"3 Array 3 Wiring No. Descrip tio n Date 1895 & 1995 S Standard Ave1/7/2025 2 (1) #6 AWG CU THWN-2 EGC (2) #10 AWG CU PV WIRE DISTANCE: 100 FT, 0.53% VDROP 3 (1) #6 AWG CU THWN-2 EGC (6) #10 AWG CU PV WIRE FILL: 0.3397 IN^2 1" IMC ON STRUCTURES, 39% FILL DISTANCE: 175 FT, 0.92% VDROP 4.1 (1) #6 AWG CU THWN-2 EGC (1) #4 AWG CU THWN-2 NEUT (3) #3/O AWG CU THWN-2 FILL: 0.9368 IN^2 2" EMT ON STRUCTURES, 28% FILL DISTANCE: 10 FT, 0.05% VDROP 4.2 (1) #6 AWG CU THWN-2 EGC (1) #6 AWG CU THWN-2 NEUT (3) #1 AWG CU THWN-2 FILL: 0.57 IN^2 1.25" EMT ON STRUCTURES, 38% FILL DISTANCE: 10 FT, 0.06% VDROP 5.1 (1) #1/O AWG CU THWN-2 EGC (1) #3/O AWG CU THWN-2 NEUT (3) #600 MCM CU THWN-2 (2) PARALLEL RUNS (2) CONDUITS, IN EACH: FILL: 3.0562 IN^2 3" EMT ON STRUCTURES, 35% FILL DISTANCE: 125 FT, 0.23% VDROP 5.2 (1) #3/O AWG AL THWN-2 EGC (1) #250 MCM AL THWN-2 NEUT (3) #900 MCM AL THWN-2 (2) PARALLEL RUNS (2) CONDUITS, IN EACH: FILL: 4.3582 IN^2 3.5" EMT ON STRUCTURES, 38% FILL DISTANCE: 125 FT, 0.25% VDROP 6 (1) #2/O AWG CU THWN-2 EGC (1) #600 MCM CU THWN-2 NEUT (3) #600 MCM CU THWN-2 (2) PARALLEL RUNS (2) CONDUITS, IN EACH: FILL: 3.6559 IN^2 3.5" IMC ON STRUCTURES, 32% FILL DISTANCE: 15 FT, 0.03% VDROP 1 (1) #6 AWG CU THWN-2 EGC (2) #10 AWG CU PV WIRE DISTANCE: 1 FT, 0.03% VDROP (N) PV AC DISCONNECT 1 600VAC, 3P, 800A, NEMA 3R W/ 800A FUSES, 65 kAIC VISIBLE / LOCKABLE FOR UTILITY OPERATION (TO BECOME MAIN SINGLE POINT OF DISCONNECT ONCE NEW FUTURE MAIN SWITCHGEAR IS INSTALLED) G G INV JBOX TYP DC DC INV 1 -120 kW STRINGS 1-3 110 MODULES 1 120 JBOX TYP DC DC INV 1 -120 kW STRINGS 4-6 110 MODULES (N) 200A/3P 800A X1 TO SYNGERGY UNIT 138 (N) 125A/3P G G INV JBOX TYP DC DC INV 3 -80 kW STRINGS 1-3 108 MODULES 3 80 JBOX TYP DC DC INV 3 -80 kW STRINGS 4-6 113 MODULES PER MODULE PER STRING JBOX TYP DC DC INV 1 -120 kW STRINGS 7-9 110 MODULES G G INV JBOX TYP DC DC INV 2 -120 kW STRINGS 1-3 108 MODULES 2 120 JBOX TYP DC DC INV 2 -120 kW STRINGS 4-6 108 MODULES JBOX TYP DC DC INV 2 -120 kW STRINGS 7-9 110 MODULES (N) 200A/3P FAULT CURRENT CALCULATIONS: *PER PLD SPEC 11A, CONFIRM ALUMINUM IS APPROVED WITH OWNER PRIOR TO INSTALLATION. FINAL 24" CONDUIT LENGTH TO INVERTER IS LFMC TO FACILITATE FUTURE INVERTER REPLACEMENT. FINAL 24" CONDUIT LENGTH TO INVERTER IS LFMC TO FACILITATE FUTURE INVERTER REPLACEMENT. FINAL 24" CONDUIT LENGTH TO INVERTER IS LFMC TO FACILITATE FUTURE INVERTER REPLACEMENT. NOTES: 1. PROVIDE CONTINUOUS PATH FOR GROUND CONDUCTOR FROM THE INVERTER TO THE EXISTING MAIN SERVICE SWITCHBOARD GROUND BUS. GROUNDING ELECTRODE CONDUCTOR TO SERVE AS EQUIPMENT GROUND. PROVIDE LAY-IN LUGS TO BOND ALL EQUIPMENT ALONG THIS PATH TO THE GROUNDING ELECTRODE CONDUCTOR TO ALLOW FOR CONTINUOUS RUN. TUSTIN MCAF: COLD DESIGN TEMP = 2°C HOT DESIGN TEMP = 31°C PROJECT TOTAL TOTAL SYSTEM SIZE: 425.345 kW DC, 392.445 kW ACcec PANEL SPECS: (877) HANWHA Q CELLS, Q.PEAK DUO XL-G10.3/BFG 485 MODULE AMPERAGE: 10.63 IMP, 11.16 ISC MODULE VOLTAGE: 45.63 VMP, 53.63 VOC TEMP. COEFFICIENTS OF Voc: -0.27%/°C STC: 485W, PTC: 454.3 W INVERTER SPECS: (2) SOLAREDGE TECHNOLOGIES, SE120KUS [480V] 277/480V, 3PH, 4W, MAX OUTPUT CURRENT = 144.3A CEC WEIGHTED EFFICIENCEY: 98.5% (1) SOLAREDGE TECHNOLOGIES, SE80KUS [480V] 277/480V, 3PH, 4W, MAX OUTPUT CURRENT = 96.5A CEC WEIGHTED EFFICIENCEY: 98.5% OPTIMIZER/RAPID SHUTDOWN SPECS: (439) SOLAREDGE PER P1101 OPTIMIZER RATED INPUT DC POWER = 1101W MAX OUTPUT CURRENT = 18A MAXIMUM OUTPUT VOLTAGE = 80V MAX SYSTEM VOLTAGE = 1,000V SEE SPEC SHEET FOR ELECTRICAL PARAMETERS AND WARRANTY INFO KEY PANELS PER STRING STRINGS PER SYNERGY UNIT ARRAY DC DC SOLAREDGE P1101 POWER OPTIMIZER (2) MODULES PER X2 TO SYNERGY UNIT XXX X1 TO SYNERGY UNITXXX (N) 800A PV SUB 1, 277/480V, 3PH, 4W MLO, NEMA 3R, 42 kAIC INTEGRATED DC DISCONNECT, 1000VDC INVERTER NUMBER INVERTER SIZE (kW) X G G INV XX X2X3 COPPER OPTION: COPPER OPTION: ALUMINUM OPTION (PIN ADAPTORS REQUIRED): ETHERNET CAT5E/CAT6 (1" EMT) SERIAL/RS485 (1" EMT) SE R I A L / R S 4 8 5 (1 " E M T ) DA I S Y C H A I N I N V E R T E R S (N) DAS-1 MONITORING CONTROL PANEL WITH REVENUE GRADE METER & SOLAREDGE COMMUNICATIONS GATEWAY. (N) METER 1 FACILITY CONSUMPTION METER SERIAL/RS485 24VDC 4W, 1G #12 AWG CU THWN-2 (1" EMT) (N) 15A/3P (N) 15A/2P 3W, 1G #12 AWG CU THWN-2 (1" EMT) 4W, 1G #12 AWG CU THWN-2 (1" EMT) X2 TO SYNGERGY UNIT 1 36 X1 TO SYNGERGY UNIT 238 X2 TO SYNGERGY UNIT 2 36 X1 TO SYNGERGY UNIT 338 X2 TO SYNGERGY UNIT 3 36 X3 TO SYNGERGY UNIT 136 X3 TO SYNGERGY UNIT 236 X3 TO SYNGERGY UNIT 136 X2 TO SYNGERGY UNIT 238 SE R I A L / R S 4 8 5 (1 " E M T ) DA I S Y C H A I N I N V E R T E R S PER INPUT: G X1 TO SYNGERGY UNIT 2 37 X1 TO SYNGERGY UNIT 338 X2 TO SYNGERGY UNIT 3 36 LINE SIDE TAP NEC 705.12(A)(1) (N) 15A/3P MAX VOLTAGE DROP MODULE TO OPTIMIZER = 0.03% OPTIMIZER TO JBOX = 0.53% JBOX TO INVERTER = 0.92% INVERTER TO COMBINER = 0.06% COMBINER TO AC DISCONENCT = 0.25% AC DISCONENCT TO MAIN SERVICE = 0.03% TOTAL = 1.82% EX T E R I O R E L E C T R I C A L R O O M IN T E R I O R E L E C T R I C A L R O O M DC CONDUIT SCHEDULE: (2) #10 AWG CU PV WIRE PER STRING (1) #10 AWG CU THWN-2 EGC PER CONDUIT #STRINGS FILL IMC SIZE/FILL %EMT SIZE/FILL%PVC SIZE/FILL% 1 0.1273 0.75"/22%0.75"/24%0.75"/31% 2 0.2335 1"/24%1"/27%1"/34% 3 0.3397 1"/35%1"/39%1.25"/27% 4 0.4459 1.25"/27%1.25"/30%1.25"/36% 35% -OR - 3.5" EMT ON STRUCTURES, 34% FILL (IF APPROVED BY SYSTEM OWNER) 3xCT ROGOWSKI CT-M1 X1 MMMM 4000A BUS (F) 2000A/3P MAIN W/GFPGFP (F) GROUND SYSTEM GRD (F) MAIN SWITCHBOARD "MSA" 480/277V, 3PH, 4W, 100kAIC (F) EV CHARGERS (F) EV CHARGERS (E) PANEL "HHA" (F) 600A/3P MAIN (F) 600A/3P MAIN(F) 200AS 200AF 3P 2000A BUS 2000A BUS (E) MAIN SWITCHBOARD "MS-B" 480/277V, 3PH, 4W, 65kAIC CIRCUIT TO BE ABANDONED IN FUTURE (F)600A BUS METER FOR 1995 TO BE REMOVED BY UTILITY IN THE FUTURE (E) 600AF (E) 600AT, 3P (E) DISTRIBUTION PANEL "DP1" METER FOR 1801 TO BE REMOVED BY UTILITY IN THE FUTURE METER FOR HHA TO BE REMOVED BY UTILITY IN THE FUTURE (E) 800AF (E) 400AT, 3P (F) 800AT, 3P (E) DISTRIBUTION PANEL "DP2" METER FOR 1895 TO BE REMOVED BY UTILITY IN THE FUTURE (E) 800AS (E) 600AF, 3P UTILITY SERVICE (E) GROUND SYSTEM GRD (E) MISC. LOADS 1895 S STANDARD AVE SANTA ANA, CA 92707 METER# 259000-097541 1995 S STANDARD AVE SANTA ANA, CA 92707 METER#259000-036083 (F) CONDUIT & CONDUCTORS FROM SEPARATE PERMIT NOTE:FUTURE EQUIPMENT (F) TO BE INSTALLED AS PART OF A SEPARATE PERMIT. THIS EQUIPMENT IS SHOWN FOR CLARITY ONLY. SUBJECT TO CHANGE ON OTHER PERMIT. RO O F T O P EX T E R I O R E L E C T R I C A L R O O M (3) TWISTED PAIR LEADS (1" EMT) (N) WEATHER STATION 1 SERIAL/RS485 24VDC (F) FUTURE EQUIPMENT (N) 250A/3P FOR FUTURE COMBINED SYSTEM (F) 1995 S STANDARD AVE METER UT I L I T Y CU S T O M E R (E) 800A SECTION (E) 800A SECTION THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 11 / 7 / 2 0 2 4 1 0 : 5 2 : 4 4 A M Ut i l i t y C u s t o m e r N a m e : P r o l o g is L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 19 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-9.1 Si n g l e L i n e D i a g r a m S y s t e m 1 SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 12" = 1'-0"1 Single Line Diagram System 1 WIRING CHART Ca l l o u t # Am p s I s c NE C M u l t Am p s M a x Pa r a l l e l R u n s Nu m b e r C o n d u c t o r s Si z e C o n d u c t o r Co n d u c t o r M a t l In s u l a t i o n C o n d u c t o r Si z e N e u t r a l Si z e G r o u n d Co n d u i t Q t y Wi r e T e m p R a t i n g Wi r e A m b T e m p Wi r e R o o f T e m p Wi r e T e m p T o t a l Co n d u c t o r s C u r r e n t C a r r y i n g . . 1 11.16 1.56 17 1 2 #10 AWG CU PV WIRE NA #6 AWG 1 90 31 0 31 2 2 18 1.25 23 1 2 #10 AWG CU PV WIRE NA #6 AWG 1 90 31 0 31 2 3 18 1.25 23 1 6 #10 AWG CU PV WIRE NA #6 AWG 1 90 31 0 31 6 4.1 144.3 1.25 180 1 3 #3/O AWG CU THWN-2 #4 AWG #6 AWG 1 90 31 0 31 3 4.2 96.5 1.25 121 1 3 #1 AWG CU THWN-2 #6 AWG #6 AWG 1 90 31 0 31 3 5.1 385.1 1.25 481 2 3 #600 MCM CU THWN-2 #3/O AWG #1/O AWG 2 90 31 0 31 3 5.2 385.1 1.25 481 2 3 #900 MCM AL THWN-2 #250 MCM #3/O AWG 2 90 31 0 31 3 6 385.1 1.25 481 2 3 #600 MCM CU THWN-2 #600 MCM #2/O AWG 2 90 31 0 31 3 WIRE RATING CHART Pa r a l l e l R u n s Wi r e A m p R a t i n g Wi r e T e m p D e r a t e Wi r e C o n d u c t o r D e r a t e Derated Wire Rating <= Amps Max . . 1 40 0.96 1 1 X 40A X 0.96 X 1 = 38 >= 17 1 40 0.96 1 1 X 40A X 0.96 X 1 = 38 >= 23 1 40 0.96 0.8 1 X 40A X 0.96 X 0.8 = 31 >= 23 1 225 0.96 1 1 X 225A X 0.96 X 1 = 216 >= 180 1 145 0.96 1 1 X 145A X 0.96 X 1 = 139 >= 121 2 475 0.96 1 2 X 475A X 0.96 X 1 = 912 >= 481 2 480 0.96 1 2 X 480A X 0.96 X 1 = 922 >= 481 2 475 0.96 1 2 X 475A X 0.96 X 1 = 912 >= 481 TERMINATION... Te r m T e m p R a t i n g Term Amp Rating >=Amps Max . . 60 30 >=17 60 30 >=23 60 30 >=23 75 200 >=180 75 130 >=121 75 840 >=481 75 850 >=481 75 840 >=481 VOLTAGE DROP CHART Vd r o p A m p s I m p Vd r o p V m p Vd r o p D i s t a n c e Vd r o p P e r c e n t . . 10.63 91.26 1 0.03 18 850 100 0.53 18 850 175 0.92 144.3 480 10 0.05 96.5 480 10 0.06 385.1 480 125 0.23 385.1 480 125 0.25 385.1 480 15 0.03 * * NOTE: ALL TERMINATIONS TO BE RATED TO 75°C OR MORE Ut i l i t y M e t e r C u s t o m e r A d d r e s s : 1 9 9 5 S S T A N D A R D , A V E S A N T A A N A , C A 9 2 7 0 7 Ut i l i t y C u s t o m e r N a m e : P r o l o g i s L o g i s t i c S e r v I n c . No. Descrip tio n Date 1895 & 1995 S Standard Ave1/7/2025 2 (1) #6 AWG CU THWN-2 EGC (2) #10 AWG CU PV WIRE DISTANCE: 100 FT, 0.53% VDROP 3 (1) #6 AWG CU THWN-2 EGC (6) #10 AWG CU PV WIRE FILL: 0.3397 IN^2 1" IMC ON STRUCTURES, 39% FILL DISTANCE: 175 FT, 0.92% VDROP 5.1 (1) #4 AWG CU THWN-2 EGC (1) #2 AWG CU THWN-2 NEUT (3) #250 MCM CU THWN-2 FILL: 1.3892 IN^2 2.5" EMT ON STRUCTURES, 24% FILL DISTANCE: 125 FT, 0.52% VDROP 5.2 (1) #2 AWG AL THWN-2 EGC (1) #1/O AWG AL THWN-2 NEUT (3) #350 MCM AL THWN-2 FILL: 1.8739 IN^2 2.5" EMT ON STRUCTURES, 32% FILL DISTANCE: 125 FT, 0.61% VDROP 6 (1) #2 AWG CU THWN-2 EGC (1) #250 MCM CU THWN-2 NEUT (3) #250 MCM CU THWN-2 FILL: 1.6704 IN^2 2.5" IMC ON STRUCTURES, 29% FILL DISTANCE: 15 FT, 0.06% VDROP 4 (1) #6 AWG CU THWN-2 EGC (1) #6 AWG CU THWN-2 NEUT (3) #1 AWG CU THWN-2 FILL: 0.57 IN^2 1.25" EMT ON STRUCTURES, 38% FILL DISTANCE: 10 FT, 0.06% VDROP 1 (1) #6 AWG CU THWN-2 EGC (2) #10 AWG CU PV WIRE DISTANCE: 1 FT, 0.03% VDROP INV JBOX TYP DC DC INV 4 -80 kW STRINGS 1-3 108 MODULES 4 JBOX TYP DC DC INV 4 -80 kW STRINGS 4-6 108 MODULES X3 TO SYNGERGY UNIT 136 PER MODULE PER STRING INV JBOX TYP DC DC INV 5 -80 kW STRINGS 1-3 108 MODULES 5 JBOX TYP DC DC INV 5 -80 kW STRINGS 4-6 108 MODULES FAULT CURRENT CALCULATIONS: *PER PLD SPEC 11A, CONFIRM ALUMINUM IS APPROVED WITH OWNER PRIOR TO INSTALLATION. FINAL 24" CONDUIT LENGTH TO INVERTER IS LFMC TO FACILITATE FUTURE INVERTER REPLACEMENT. FINAL 24" CONDUIT LENGTH TO INVERTER IS LFMC TO FACILITATE FUTURE INVERTER REPLACEMENT. NOTES: 1. PROVIDE CONTINUOUS PATH FOR GROUND CONDUCTOR FROM THE INVERTER TO THE EXISTING MAIN SERVICE SWITCHBOARD GROUND BUS. GROUNDING ELECTRODE CONDUCTOR TO SERVE AS EQUIPMENT GROUND. PROVIDE LAY-IN LUGS TO BOND ALL EQUIPMENT ALONG THIS PATH TO THE GROUNDING ELECTRODE CONDUCTOR TO ALLOW FOR CONTINUOUS RUN. TUSTIN MCAF: COLD DESIGN TEMP = 2°C HOT DESIGN TEMP = 31°C PROJECT TOTAL TOTAL SYSTEM SIZE: 209.52 kW DC, 193.313 kW ACcec PANEL SPECS: (432)HANWHA Q CELLS, Q.PEAK DUO XL-G10.3/BFG 485 MODULE AMPERAGE: 10.63 IMP, 11.16 ISC MODULE VOLTAGE: 45.63 VMP, 53.63 VOC TEMP. COEFFICIENTS OF Voc: -0.27%/°C STC: 485W, PTC: 454.3 W INVERTER SPECS: (2) SOLAREDGE TECHNOLOGIES, SE80KUS [480V] 277/480V, 3PH, 4W, MAX OUTPUT CURRENT = 96.5A CEC WEIGHTED EFFICIENCEY: 98.5% OPTIMIZER/RAPID SHUTDOWN SPECS: (216) SOLAREDGE PER P1101 OPTIMIZER RATED INPUT DC POWER = 1101W MAX OUTPUT CURRENT = 18A MAXIMUM OUTPUT VOLTAGE = 80V MAX SYSTEM VOLTAGE = 1,000V SEE SPEC SHEET FOR ELECTRICAL PARAMETERS AND WARRANTY INFO KEY PANELS PER STRING STRINGS PER SYNERGY UNIT ARRAY DC DC SOLAREDGE P1101 POWER OPTIMIZER (2) MODULES PER X2 TO SYNERGY UNIT XXX X1 TO SYNERGY UNITXXX INTEGRATED DC DISCONNECT, 1000VDC INVERTER NUMBER INVERTER SIZE (kW) X G G INV XX COPPER OPTION: ALUMINUM OPTION (PIN ADAPTORS REQUIRED): ETHERNET CAT5E/CAT6 (1" EMT) SERIAL/RS485 (1" EMT) SE R I A L / R S 4 8 5 (1 " E M T ) DA I S Y C H A I N I N V E R T E R S G G80 G G80 X3 TO SYNGERGY UNIT 236 X3 TO SYNGERGY UNIT 136 X3 TO SYNGERGY UNIT 236 PER INPUT: MAX VOLTAGE DROP MODULE TO OPTIMIZER = 0.03% OPTIMIZER TO JBOX = 0.53% JBOX TO INVERTER = 0.92% INVERTER TO COMBINER = 0.06% COMBINER TO AC DISCONENCT = 0.61% AC DISCONENCT TO MAIN SERVICE = 0.06% TOTAL = 2.21% (N) PV AC DISCONNECT 2 600VAC, 3P, 400A, NEMA 3R W/ 250A FUSES, 65 kAIC VISIBLE / LOCKABLE FOR UTILITY OPERATION (TO BE REMOVED WHEN SYSTEMS ARE COMBINED IN THE FUTURE) (N) 125A/3P 250A(N) 125A/3P (N) 250A PV SUB 2, 277/480V, 3PH, 4W MLO, NEMA 3R, 42 kAIC RO O F T O P EX T E R I O R E L E C T R I C A L R O O M X2X3 COPPER OPTION: (N) DAS-1 MONITORING CONTROL PANEL WITH REVENUE GRADE METER & SOLAREDGE COMMUNICATIONS GATEWAY. (N) WEATHER STATION 1 SE R I A L / R S 4 8 5 24 V D C (N) METER 1 FACILITY CONSUMPTION METER SERIAL/RS485 24VDC 4W, 1G #12 AWG CU THWN-2 (1" EMT) 3xCT ROGOWSKI CT-M1 (3) TWISTED PAIR LEADS (1" EMT) (N) 15A/3P (N) 15A/2P 3W, 1G #12 AWG CU THWN-2 (1" EMT) 4W, 1G #12 AWG CU THWN-2 (1" EMT) G #1/0 AWG CU MAIN BONDING JUMPER X1 LINE SIDE TAP NEC 705.12(A)(1) (N) 15A/3P EX T E R I O R E L E C T R I C A L R O O M IN T E R I O R E L E C T R I C A L R O O M -OR - 2.5" EMT ON STRUCTURES, 29% FILL (IF APPROVED BY SYSTEM OWNER) MMMM 4000A BUS (F) 2000A/3P MAIN W/GFPGFP (F) GROUND SYSTEM GRD (F) MAIN SWITCHBOARD "MSA" 480/277V, 3PH, 4W, 100kAIC (F) EV CHARGERS (F) EV CHARGERS (E) PANEL "HHA" (F) 600A/3P MAIN (F) 600A/3P MAIN(F) 200AS 200AF 3P 2000A BUS 2000A BUS (E) MAIN SWITCHBOARD "MS-B" 480/277V, 3PH, 4W, 65kAIC CIRCUIT TO BE ABANDONED IN FUTURE (F)600A BUS (E) 600AF (E) 600AT, 3P (E) DISTRIBUTION PANEL "DP1" (E) 800AF (E) 400AT, 3P (F) 800AT, 3P (E) DISTRIBUTION PANEL "DP2" (E) 800AS (E) 600AF, 3P UTILITY SERVICE (E) GROUND SYSTEM GRD (E) MISC. LOADS 1895 S STANDARD AVE SANTA ANA, CA 92707 METER# 259000-097541 1995 S STANDARD AVE SANTA ANA, CA 92707 METER#259000-036083 (F) CONDUIT & CONDUCTORS FROM SEPARATE PERMIT NOTE:FUTURE EQUIPMENT (F) TO BE INSTALLED AS PART OF A SEPARATE PERMIT. THIS EQUIPMENT IS SHOWN FOR CLARITY ONLY. SUBJECT TO CHANGE ON OTHER PERMIT. (F) FUTURE EQUIPMENT (F) 1995 S STANDARD AVE METER METER FOR 1995 TO BE REMOVED BY UTILITY IN THE FUTURE METER FOR 1801 TO BE REMOVED BY UTILITY IN THE FUTURE METER FOR HHA TO BE REMOVED BY UTILITY IN THE FUTURE METER FOR 1895 TO BE REMOVED BY UTILITY IN THE FUTURE UT I L I T Y CU S T O M E R (E) 800A SECTION (E) 800A SECTION THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 11 / 7 / 2 0 2 4 1 0 : 5 2 : 4 4 A M Ut i l i t y C u s t o m e r N a m e : P r o l o g is L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 19 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-9.2 Si n g l e L i n e D i a g r a m S y s t e m 2 SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 12" = 1'-0"1 Single Line Diagram System 2 * NOTE: ALL TERMINATIONS TO BE RATED TO 75°C OR MORE TERMINATION... Te r m T e m p R a t i n g Term Amp Rating >=Amps Max . . 60 30 >=17 60 30 >=23 60 30 >=23 75 130 >=121 75 255 >=241 75 250 >=241 75 255 >=241 VOLTAGE DROP CHART1 Vd r o p A m p s I m p Vd r o p V m p Vd r o p D i s t a n c e Vd r o p P e r c e n t . . 10.63 91.26 1 0.03 18 850 100 0.53 18 850 175 0.92 96.5 480 10 0.06 193 480 125 0.52 193 480 125 0.61 193 480 15 0.06 WIRE RATING CHART1 Pa r a l l e l R u n s Wi r e A m p R a t i n g Wi r e T e m p D e r a t e Wi r e C o n d u c t o r D e r a t e Derated Wire Rating <= Amps Max . . 1 40 0.96 1 1 X 40A X 0.96 X 1 = 38 >= 17 1 40 0.96 1 1 X 40A X 0.96 X 1 = 38 >= 23 1 40 0.96 0.8 1 X 40A X 0.96 X 0.8 = 31 >= 23 1 145 0.96 1 1 X 145A X 0.96 X 1 = 139 >= 121 1 290 0.96 1 1 X 290A X 0.96 X 1 = 278 >= 241 1 280 0.96 1 1 X 280A X 0.96 X 1 = 269 >= 241 1 290 0.96 1 1 X 290A X 0.96 X 1 = 278 >= 241 WIRING CHART1 Ca l l o u t # Am p s I s c NE C M u l t Am p s M a x Pa r a l l e l R u n s Nu m b e r C o n d u c t o r s Si z e C o n d u c t o r Co n d u c t o r M a t l In s u l a t i o n C o n d u c t o r Si z e N e u t r a l Si z e G r o u n d Co n d u i t Q t y Wi r e T e m p R a t i n g Wi r e A m b T e m p Wi r e R o o f T e m p Wi r e T e m p T o t a l Co n d u c t o r s C u r r e n t C a r r y i n g . . 1 11.16 1.56 17 1 2 #10 AWG CU PV WIRE NA #6 AWG 1 90 31 0 31 2 2 18 1.25 23 1 2 #10 AWG CU PV WIRE NA #6 AWG 1 90 31 0 31 2 3 18 1.25 23 1 6 #10 AWG CU PV WIRE NA #6 AWG 1 90 31 0 31 6 4 96.5 1.25 121 1 3 #1 AWG CU THWN-2 #6 AWG #6 AWG 1 90 31 0 31 3 5.1 193 1.25 241 1 3 #250 MCM CU THWN-2 #2 AWG #4 AWG 1 90 31 0 31 3 5.2 193 1.25 241 1 3 #350 MCM AL THWN-2 #1/O AWG #2 AWG 1 90 31 0 31 3 6 193 1.25 241 1 3 #250 MCM CU THWN-2 #250 MCM #2 AWG 1 90 31 0 31 3 THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 11 / 7 / 2 0 2 4 1 0 : 5 2 : 4 4 A M Ut i l i t y C u s t o m e r N a m e : P r o l o g is L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 19 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-9.2 Si n g l e L i n e D i a g r a m S y s t e m 2 SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 Ut i l i t y M e t e r C u s t o m e r A d d r e s s : 1 8 9 5 S S T A N D A R D , A V E S A N T A A N A , C A 9 2 7 0 7 Ut i l i t y C u s t o m e r N a m e : P r o l o g i s L o g i s t i c S e r v I n c . No. Descrip tio n Date No. Descrip tio n Date 1895 & 1995 S Standard Ave1/7/2025 Santa Ana, CA CLIENT: Axis Solar 805.496.2100 • VinciSE.com 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ARRAY JOB NO: 22-3457 Santa Ana Distribution Center 1 1995 S Standard Ave & 1895 S Standard Ave V I N C I & A S S O C I A T E S Structural Engineers STRUCTURAL CALCULATIONS FOR PHOTOVOLTAIC 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Santa Ana Distribution Center 1 Structural Engineers JOB NO.:22-3457 1995 S Standard Ave & 1895 S Standard Ave175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Axis Solar DESIGN DATA: ROOF DESIGN LOAD: ROOFING ( Built Up )=5 psf SHEATHING =2 ROOF RAFTERS / TRUSS =2 MISCELLANEOUS =1 ROOF RAFTER/TRUSS DESIGN DEAD LOAD =10.0 psf CEILING & INSULATION =0 MISCELLANEOUS =1.25 DESIGN DEAD LOAD =11.3 psf DESIGN LIVE LOAD =20 psf DESIGN SNOW LOAD =0 psf WIND DESIGN CRITERIA: BASIC WIND SPEED =100 mph WIND EXPOSURE =C NUMBER OF STORIES =1 ROOF SLOPE =0° SOLAR MODULE Solar Module Width:=41.14 in Solar Module Length:=87.24 in Solar Module Area =24.92 ft2 Solar Module Dead Load =2.85 psf Number of PV Modules =485 Number of Ballast Trays =485 UPLIFT DESIGN BY BALLAST COMPANY TOTAL AREA OF ADDED SOLAR PANELS (PER BALLAST CALCS =42856.0 ft2 5/14/2024 - 1895 & 1995 S Standard Ave1/7/2025 DATE:SHEET: PROJECT:Santa Ana Distribution Center 1 JOB NO.:19-3457 1995 S Standard Ave & 1895 S Standard Ave ENGR.:JRV Santa Ana, CA CLIENT:Axis Solar Check Attachment with Calculations Anchor Screw Check Design Loads:Uplift:525 lbs (from Ballast Company)Lateral:650 lbs Roof Material 1/2" Roof Sheathing Number of Screws/conn:6 screws Load Duration Factor (Cd)1.6 ('12 NDS) Fastener Factor of Safety:3 Screw Size #12 Sheet Metal Screws VUltimate =670 lbs TUltimate =315 lbs Vdesign =Vultimate x Cd / FOS =357.3 lbs Tdesign =Tultimate x Cd / FOS =168 lbs (Values taken from APA technical Note E830E into 1/2" sheathing) CHECK CONNECTION SHEAR: TOTAL SHEAR:650 lbs NO. OF SCREWS/CONN:4 connections minimum SHEAR / SCREW:162.5 lbs/conn <357 lbs O.K. CHECK CONNECTION UPLIFT: TOTAL UPLIFT:525 lbs NO. OF SCREWS/CONN:4 connections minimum SHEAR / SCREW:131.25 lbs/conn <168 lbs O.K. CHECK UNITY: 162.5 lb +131.3 lb =1.24 <1.33 O.K. 357.3 lb 168.0 lb USE: #12 x 1-1/2" SHEET METAL SCREWS INTO 1/2" ROOF SHEATHING Anchor Plate Connection Check Anchor Type:U Anchor 2400/2600 Factor of Safety Ultimate Tension Capacity:1211 lbs 2.31 Ultimate Shear Capacity:1968 lbs 3.03 5/14/2024 V I N C I & A S S O C I A T E S Structural Engineers 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 805.496.2100 • VinciSE.com Panel Claw U-Anchor 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Santa Ana Distribution Center 1 Structural Engineers JOB NO.:22-3457 1995 S Standard Ave & 1895 S Standard Ave175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Axis Solar LATERAL FORCES: (Base Shear Calculations -2022 CBC /ASCE-16 ) SEISMIC: Site Class:D (Use D if unknown) S1=0.456 (USGS Software)SS=1.28 (USGS Software) Fv =1.7 (Table 11.4-2)Fa =1.2 (Table 11.4-1) I =1.0 (Sec 1.5-2 ASCE 7-16) R =5.0 (Table 12.2-1 ASCE 7-16) SMS =Fa * SS =1.531 (Eq. 16-20)SDS = (Eq. 16-39) SM1=Fv * S1 =0.775 (Eq. 16-21)SD1 = (Eq. 16-40) TL = 8 s (Fig 22-14, ASCE 7) Ts = SD1 / SDS =0.506 s 80% x 0.506 = >0.189 s Ta = Ct * (hn)x =(Eq. 12.8-7)Ct =0.02 (Table 12.8-2 ASCE 7-16) hn =20.0 ft x =0.75 (Table 12.8-2 ASCE 7-16) k = 1.0 * *GOVERNS * * VMIN = ( SDS) / ( R / I ) =0.20 W (Eq. 12.8-2 ASCE 7-16) NEED NOT EXCEED: IF T ≤ TL USE: V = ( SD1) / T *( R / I ) =W (Eq. 12.8-3 ASCE 7-16) IF T TL USE: V = ( SD1)*(TL) / T² *( R / I ) =W (Eq. 12.8-4 ASCE 7-16) SHALL NOT BE LESS THAN: V = W (Eq. 12.8-5 ASCE 7-16) 0.405 0.01 23.11 0.55 5/14/2024 0.189 s 1.02 0.52 ²/3 * SMS = ²/3 * SM1 = 1895 & 1995 S Standard Ave1/7/2025 USGS web servi ces we re do wn fo r so m e p e ri od of ti m e and as a resul t th i s too l wasn't ope ra ti ona l , resul ti ng i n ti meou t erro r. USGS we b servi ce s are n ow ope rati onal so thi s to o l sh oul d work as e xpecte d. 1995 S Standard Av e , Santa Ana, CA 92707, USA Latitude , Long itu de : 33.7223933, -117.8553474 Date 5 /1 4/2 024 , 12:52:21 PM Design Code Refere nce Doc ument ASCE7-16 Ris k Category II Site Class D - Defa ul t (See Secti on 11 .4.3) Type Value Desc ription SS 1 .2 7 6 M CER g ro u nd m oti o n . (fo r 0.2 second pe ri od) S1 0 .4 5 6 M CER g ro u nd m oti o n . (fo r 1.0s pe ri od) SMS 1 .5 3 1 Si te-m o di fi ed sp ectral accel erati o n val ue SM1 n ul l -Se e S ecti on 11.4.8 Si te-m o di fi ed sp ectral accel erati o n val ue SDS 1 .0 2 Nu m eri c sei sm i c d esi gn val u e at 0.2 se con d SA SD1 n ul l -Se e S ecti on 11.4.8 Nu m eri c sei sm i c d esi gn val u e at 1.0 se con d SA Type Va lue De scription SDC nu l l -See Se cti o n 11.4.8 Sei sm i c de si gn categ o ry Fa 1.2 Si te a m p l i fi ca ti on factor a t 0.2 se cond Fv nu l l -See Se cti o n 11.4.8 Si te a m p l i fi ca ti on factor a t 1.0 se cond PGA 0.539 M CEG pe a k groun d a cce l e rati on FPGA 1.2 Si te a m p l i fi ca ti on factor a t PGA PGAM 0.646 Si te m od i fi e d peak g ro und accel erati o n T L 8 Lo n g-peri o d transi ti on peri o d i n seco n ds SsRT 1.276 Proba b i l i sti c ri sk-targeted groun d m o ti on. (0 .2 se con d) SsUH 1.37 Fa cto re d u ni fo rm -haza rd (2% pro bab i l i ty of e xce eda n ce i n 5 0 yea rs) sp ectra l accel erati o n SsD 1.629 Fa cto re d d eterm i ni sti c accel e ra ti on va l u e . (0.2 seco nd) S1RT 0.456 Proba b i l i sti c ri sk-targeted groun d m o ti on. (1 .0 se con d) S1UH 0.492 Fa cto re d u ni fo rm -haza rd (2% pro bab i l i ty of e xce eda n ce i n 5 0 yea rs) sp ectra l accel erati o n . 5/14/24, 12:54 PM U.S. Seis mic Des ign Maps https ://w w w .s eis mic maps .org 1/3 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Santa Ana Distribution Center 1 Structural Engineers JOB NO.:22-3457 1995 S Standard Ave & 1895 S Standard Ave175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Axis Solar LATERAL FORCES:(BASE SHEAR - Conservative) 2022 CBC F1 SEISMIC BASE SHEAR: V =0.20 W (SEE PREVIOUS)h1 =20.0 ft F1 ROOF =11 PSF WALLS =7 18.1 x 0.204 3.70 PSF WIND LOADS: Governs ps = λ kzt Iw ps30 (Eq. 6-1) λ =1.21 ps30A =psf psA psf Iw = 1.00 ps30B =psf psB psf kzt = 1.00 ps30C =psf psC psf ps30D =psf psD psf F1ULT:= ( 2 ft + 20 ft /2 ) x (23.2704 psf +12.12 psf ) =425 lb/ft F1ASD:=lb/ft x 0.6 =255 lb/ft424.68 2.0 ft 23.27 -12.12 15.39 -7.15 19.20 -10.00 12.70 -5.90 5/14/2024 hROOF= - 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Santa Ana Distribution Center 1 Structural Engineers JOB NO.:22-3457 1995 S Standard Ave & 1895 S Standard Ave175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Axis Solar CHECK IMPACT OF NEW SOLAR PANELS ON SEISMIC LOAD ADD ROOF PLAN HERE TOTAL ROOF AREA: (1000.0 ft x 280 ft ) + (0.0 ft x 0.0 ft ) + (0.0 ft x 0.0 ft ) + (0.0 ft x 0.0 ft ) = EXISTING ESTIMATED SEISMIC LOAD (BASE SHEAR) 280000 ft2 x 3.70 psf =1035091 lbs AREA OF ADDED SOLAR PANELS (PER PAGE 1)=ft2 WEIGHT OF PANELS:2.85 psf ADDED SEISMIC LOAD: 2.85 psf x ft2 x 0.20 =24936.0 lbs Therefore O.K. Per CEBC SECTION 503.4 5/14/2024 - 280000 ft2 42856.0 42856.0 =2.4%<10%% INCREASE =24936.0 1035091.2 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Santa Ana Distribution Center 1 Structural Engineers JOB NO.:22-3457 1995 S Standard Ave & 1895 S Standard Ave175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Axis Solar CHECK IMPACT OF NEW SOLAR PANELS ON GRAVITY LOAD ADD ROOF PLAN HERE TOTAL ROOF AREA: (1000.0 ft x 280 ft ) + (0.0 ft x 0.0 ft ) + (0.0 ft x 0.0 ft ) + (0.0 ft x 0.0 ft ) = EXISTING ESTIMATED GRAVITY LOAD 280000 ft2 x 11.25 psf =3150000 lbs AREA OF ADDED SOLAR PANELS (PER PAGE 1)=ft2 WEIGHT OF PANELS:2.85 psf ADDED GRAVITY LOAD: 2.85 psf x ft2 x 1 =122139.6 lbs Therefore O.K. 5/14/2024 - 280000 ft2 42856.0 42856.0 % INCREASE =122139.6 =3.9%<5% 3150000 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Santa Ana Distribution Center 1 Structural Engineers JOB NO.:22-3457 1995 S Standard Ave & 1895 S Standard Ave175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Axis Solar CHECK OF EXISTING ROOF STRUCTURE Existing Roof Dead Load 11.25 psf Existing Roof Live Load:20 psf reducable PV Array Dead Load 2.85 psf Per 2022 California Building Code Section 1607.14.4.1 when a PV array is installed less than 24" above the surface of the roof surface, the live load can be ignored below the PV array. Therefore - if the 20 psf (12psf min when reduced) is eliminated below the proposed PV Arrays, the roof is more than capable of supporting the additional 2.85 psf dead load due to the proposed array. Therefore, by observation, the existing roof structure is sufficient. 5/14/2024 1895 & 1995 S Standard Ave1/7/2025 Santa Ana, CA CLIENT: Axis Solar Power 805.496.2100 • VinciSE.com 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ARRAY JOB NO: 22-3457 Santa Ana Distribution Center 1 1995 S Standard Ave & 1895 S Standard Ave V I N C I & A S S O C I A T E S Structural Engineers STRUCTURAL CALCULATIONS FOR EQUIPMENT 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Santa Ana Distribution Center 1 Structural Engineers JOB NO.:22-3457 1995 S Standard Ave & 1895 S Standard Ave175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Axis Solar Power PROJECT DATA Fp =0.51 37 psf x area 1 180 #2.16 ft 3.08 ft 6.7 ft2 2 180 #2.16 ft 3.08 ft 6.7 ft2 3 180 #2.16 ft 3.08 ft 6.7 ft2 4 5 6 7 8 9 10 Axis =1-1 2-2 F.O.S. =3 Area =in2 Tallow =1325.3 lb I x =0.185 0.236 in4 (area of bolt x 36,000 psi / FOS) Sx =0.202 0.29 in3 Vallow =994.0 lb r x =0.577 0.651 in ((area of bolt x 36,000 psi / FOS) x .75) Fb =psi WIND GOVERNS Unistrut P1000 33000 243 # 243 # 243 # Weight 92 # AreaHeightWidthEquip Mark 92 # 92 # BOLT PROPERTIES 0.555 3/8" Bolt (MIN) BEAM / COLUMN / BRACE PROPERTIES 5/14/2024 Horizontal Forces Seismic Wind 1 1895 & 1995 S Standard Ave1/7/2025 PROJECT : PAGE : CLIENT : DESIGN BY : INPUT DATA & DESIGN SUMMARY BASIC WIND VELOCITY V = 100 mph, (160.93 kph) EXPOSURE TYPE (B, C, D)== > C SCREEN TOP ELEVATION H = 21 ft, (6.40 m) HEIGHT OF STRUCTURE ( < 60 ft) h = 18 ft, (5.49 m, ASCE 7-22 26.10.2) BUILDING WIDTH B = 320 ft, (97.54 m) BUILDING LENGTH L = 1150 ft, (350.52 m) SCREEN VERTICAL SIZE E = 5 ft, (1.52 m) Af =16 ft 2 (1.49 m 2 ) Ar =80 ft 2 (7.44 m 2 ) TOPOGRAPHIC FACTOR KZt =1 Flat, (26.8 & Table 26.8-1) Out-of-plane load for screen design P = 36.6 ( 1752 N/m 2 ) Fh =0.585 kips, Horizontal Fv =2.311 kips, Vertical (2.6 kN)(10.3 kN) WIND ANALYSIS Out-of-plane wind force for screen design (ASCE 7-22, 29.4.1) ( 36.6 psf ) Af =0.585 kips, Horizontal Where :G Cr =Max{ Min[ 2 - Af / (B h) , 1.9] , 1.0} =1.90 , (ASCE 7-22 Eq. 29.4-2) hc = 18.5 ft, centroid height of the screen B h = 5760 ft2, building side area (ASCE 7-22 Eq. 29.4-2) KZ = 0.89 , (ASCE 7-22 Tab. 26.10-1) Kd = 0.85 , (ASCE 7-22 26.6)Ke = 1 , (ASCE 7-22 Tab. 26.9-1) ( 28.9 psf ) Ar =2.311 kips, Vertical Where :G Cr =Max{ Min[ 2 - Ar / (B L) , 1.5] , 1.0} =1.50 , (ASCE 7-22 Eq. 29.4-3) B L = 4E+05 ft2, building side area (ASCE 7-22 Eq. 29.4-3) psf, Horizontal Wind Load, on Roof Screen / Roof Equipment, Based on ASCE 7-22 VERTICAL PROJECTED AREA HORIZONTAL PROJECTED AREA 20.00256h f d f Z Zt d frrhP G GqCV C  20.00256v r d r Z Zt d rrrhP G GqCV C  2 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Santa Ana Distribution Center 1 Structural Engineers JOB NO.: 1995 S Standard Ave & 1895 S Standard Ave175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.: Santa Ana, CA p 805.496.2100 • f 805.496.2442 • e vinci@VinciSE.com CLIENT:Axis Solar Power LATERAL FORCES: 2022 CBC SEISMIC: Site Class:D (Use D if unknown) S1=0.456 (USGS Zipcode Tables)SS=1.28 (USGS Zipcode Tables) Fv =1.7 (Table 1613.5.3-2)Fa =1.2 (Table 1613.5.3 -1) I =1.00 (Table 11.5-1 ASCE 7-16) R =1.00 (Table 12.2-1 ASCE 7-16) SMS =Fa * SS =1.531 (Eq. 16-37)SDS = ²/3 * SMS =1.02 (Eq. 16-39) SM1=Fv * S1 =0.775 (Eq. 16-38)SD1 = ²/3 * SM1 =0.52 (Eq. 16-40) TL = 8 s (Figure 22-16 ASCE 7-16) T =Ct * (hn)x =0.112 s (Eq. 12.8-7)Ct =0.02 (Table 12.8-2 ASCE 7-16) hn =10.00 ft x =0.75 (Table 12.8-2 ASCE 7-16) SEISMIC FORCES ON NONSTRUCTURAL COMPONENTS Per ASCE 7-16 Section 13.3.1 F p is not required to be greater than: Fp =1.6 SDS Ip Wp =1.63 W F p shall not be less than: Fp =0.3 SDS Ip Wp =0.31 W F p =seismic design force S DS =spectral acceleration, short period, per ASCE Section 11.4.4 W p =componant operating weight a p =2.5 (componant amplificatin factor (ASCE Table 13.5-1 or 13.6-1)) I p =1.00 (componant importance factor) R p =6.0 (componant response modification factor (ASCE Table 13.5-1 or 13.6-1)) z =10.00 ft (height in structure of point of attachment of componant with respect to the base.) h =10.00 ft (average roof height with respect to base. (z/h) <= 1.) Wp( Rp / Ip ) 5/14/2024 Fp = 0.4 ap SDS Wp (1 + 2 (z/h) )=0.51 3 1895 & 1995 S Standard Ave1/7/2025 USGS web services were down for some period of time and as a result this tool wasn't operational, resulting in timeout error. USGS web services are now operational so this tool should work as expected. 1995 S Standard Ave, Santa Ana, CA 92707, USA Latitude, Longitude: 33.7223933, -117.8553474 Date 5/14/2024, 12:52:21 PM Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Default (See Section 11.4.3) Type Value Description SS 1.276 MCER ground motion. (for 0.2 second period) S1 0.456 MCER ground motion. (for 1.0s period) SMS 1.531 Site-modified spectral acceleration value SM1 null -See Section 11.4.8 Site-modified spectral acceleration value SDS 1.02 Numeric seismic design value at 0.2 second SA SD1 null -See Section 11.4.8 Numeric seismic design value at 1.0 second SA Type Value Description SDC null -See Section 11.4.8 Seismic design category Fa 1.2 Site amplification factor at 0.2 second Fv null -See Section 11.4.8 Site amplification factor at 1.0 second PGA 0.539 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.646 Site modified peak ground acceleration T L 8 Long-period transition period in seconds SsRT 1.276 Probabilistic risk-targeted ground motion. (0.2 second) SsUH 1.37 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 1.629 Factored deterministic acceleration value. (0.2 second) S1RT 0.456 Probabilistic risk-targeted ground motion. (1.0 second) S1UH 0.492 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration. 5/14/24, 12:54 PM U.S. Seismic Design Maps https://w w w.seismicmaps.org 1/3 4 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Prologis Hain JOB NO.: 1995 S Standard Ave & 1895 S Standard Ave ENGR.: Santa Ana, CA VERTICAL FORCES ON BEAM WIND GOVERNS USE: 3 Beams X1 2.67 ft W1 60 #X2 2.67 ft W1 W2 W3 …Wn W2 60 #X3 2.67 ft X1 X2 X3 …Xn-1 Xn W3 60 #X4 W4 0 #X5 L =8.01 ft W5 0 #X6 R1 R2 W6 0 #X7 W7 0 #X8 W8 0 #X9 W1 W9 0 #X10 RY1 W2 W10 0 #X11 … RY2 Wn RY1 =60.00 # RY2 =120.00 # mMax = 480.60 #-ft mMax = 5767.20 #-in Check Horizontal Beam for Bending fb =/= FB =>THEREFORE O.K. 5,767 #-in 0.290 in3 19,887 psi 33,000 psi 19,887 psi 5/14/2024 Structural Engineers 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 805.496.2100 • VinciSE.com W X 5 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Prologis Hain JOB NO.: 5140 E Santa Ana St ENGR.: Ontario, CA HORIZONTAL FORCES ON BEAM WIND GOVERNS USE: 3 Beams X1 F1 81 #X2 F1 F2 F3 …Fn F2 81 #X3 X1 X2 X3 …Xn-1 Xn F3 81 #X4 F4 0 #X5 L =4.00 ft F5 0 #X6 R1 R2 F6 0 #X7 F7 0 #X8 F8 0 #X9 F1 F9 0 #X10 RX1 F2 F10 0 #X11 … RX2 Fn RX1 =81.14 # RX2 =162.28 # mMax = 324.56 #-ft mMax = 3894.76 #-in Check Horizontal Beam for Bending fb =/= FB =>THEREFORE O.K. Check Bi-axial Bending 19,281.0 psi 33,000 psi THEREFORE O.K. 3,895 #-in 33,000 psi 19,281 psi 19,281 psi0.202 in3 X 5/14/2024 Structural Engineers 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 805.496.2100 • VinciSE.com F +=1.19 <1.3319887 psi 33000 psi 1.25 ft 1.50 ft 1.25 ft 0.00 ft 0.00 ft 0.00 ft 0.00 ft 0.00 ft 0.00 ft 0.00 ft 0 X 6 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Prologis Hain JOB NO.: 5140 E Santa Ana St ENGR.: Ontario, CA HORIZONTAL AND VERTICAL FORCES ON COLUMN WIND GOVERNS H =5.67 ft RY1+RY2 X1 0.33 ft R2 RX1+RX2 1.17 ft X1 RX 243 #X2 2.92 ft RX 243 #X3 1.75 ft RY1+RY2 2.75 ft X2 X4 RX1+RX2 X5 X6 1.75 ft X3 X7 R1 X8 X9 RX X10 R1 X11 … R2 Rn R1 =333.15 # R2 =153.70 # mMax = 371.94 #-ft mMax = 4463.31 #-in Check Column for Bending fb =/= FB =>THEREFORE O.K. Check Column for Axial Load fa =/=360 psi Fa =kl / r =4.5 ft x k /0.577 in =94 Fa ==20000 psi Check Unity 22,096 psi 33,000 psi THEREFORE O.K. 1.33360 psi 20000 psi X 0.555 in2(RY1 + RY2) x 2 +=0.69 < 4,463 #-in 0.202 in3 22,096 psi 33,000 psi 22,096 psi 5/14/2024 Structural Engineers 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 805.496.2100 • VinciSE.com R 7 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Santa Ana Distribution Center 1 Structural Engineers JOB NO.:22-3457 1995 S Standard Ave & 1895 S Standard Ave175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Axis Solar Power CHECK LATERAL FORCE ON SOLAR ARRAY 1. Check Horiz Beam to Post Use (1) 3/8" Diameter Bolt at Each Post Pullout FX =RX1 + RX2 =243.42 # 325 #<1325 #Therefore O.K. Shear FY =RY1 + RY2 =180.00 # 481 #<994 #Therefore O.K. 2. Check Brace in Compression Unistrut P1000 L =5.48 ft FBRACE =81 # x 5.48 ft / 4 ft =111 lbs r =0.577 KL/r =114 Fa =11.13 ksi Pa =11.13 ksi x 0.555 in2 =6.17715 K F = 111 #<6177 #Therefore O.K. 3. Check Brace Connection F = 111 #<994 #(3/8" bolt)Therefore O.K. 4. Check Attachment to Roof Connection Type:Wood Anchor Type:1/4 in Lag Bolt Embedment =2.50 in Tallow =218 # x CD X pen =872 # Vallow =210 # x CD =336 # Number of Anchors =2 ALL RESISTANCE BY BRACE h =FX = a =Prying Uplift = (F x h) / b = b =FY = Unity Check +102 lbs +0.331 < 1.00 Therefore O.K. 81 lbs 81 lbs 336 lbs x 2 872 lbs 5/14/2024 9.00 in 0.875 in 7.125 in 81 # 102 # 81 # 8 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Santa Ana Distribution Center 1 Structural Engineers JOB NO.:22-3457 1995 S Standard Ave & 1895 S Standard Ave175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Axis Solar Power PROJECT DATA Fp =0.51 37 psf x area 1 180 #2.16 ft 3.08 ft 6.7 ft2 2 300 #2.50 ft 5.00 ft 12.5 ft2 3 4 5 6 7 8 9 10 Axis =1-1 2-2 F.O.S. =3 Area =in2 Tallow =1325.3 lb I x =0.185 0.236 in4 (area of bolt x 36,000 psi / FOS) Sx =0.202 0.29 in3 Vallow =994.0 lb r x =0.577 0.651 in ((area of bolt x 36,000 psi / FOS) x .75) Fb =psi Unistrut P1000 3/8" Bolt (MIN) 0.555 33000 BEAM / COLUMN / BRACE PROPERTIES BOLT PROPERTIES 92 #243 # 153 #457 # 11/7/2024 WIND GOVERNS Equip Mark Weight Width Height Area Horizontal Forces Seismic Wind 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Santa Ana Distribution Center 1 Structural Engineers JOB NO.: 1995 S Standard Ave & 1895 S Standard Ave175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.: Santa Ana, CA p 805.496.2100 • f 805.496.2442 • e vinci@VinciSE.com CLIENT:Axis Solar Power LATERAL FORCES: 2022 CBC SEISMIC: Site Class:D (Use D if unknown) S1=0.456 (USGS Zipcode Tables)SS=1.28 (USGS Zipcode Tables) Fv =1.7 (Table 1613.5.3-2)Fa =1.2 (Table 1613.5.3 -1) I =1.00 (Table 11.5-1 ASCE 7-16) R =1.00 (Table 12.2-1 ASCE 7-16) SMS =Fa * SS =1.531 (Eq. 16-37)SDS = ²/3 * SMS =1.02 (Eq. 16-39) SM1=Fv * S1 =0.775 (Eq. 16-38)SD1 = ²/3 * SM1 =0.52 (Eq. 16-40) TL = 8 s (Figure 22-16 ASCE 7-16) T =Ct * (hn)x =0.112 s (Eq. 12.8-7)Ct =0.02 (Table 12.8-2 ASCE 7-16) hn =10.00 ft x =0.75 (Table 12.8-2 ASCE 7-16) SEISMIC FORCES ON NONSTRUCTURAL COMPONENTS Per ASCE 7-16 Section 13.3.1 F p is not required to be greater than: Fp =1.6 SDS Ip Wp =1.63 W F p shall not be less than: Fp =0.3 SDS Ip Wp =0.31 W F p =seismic design force S DS =spectral acceleration, short period, per ASCE Section 11.4.4 W p =componant operating weight a p =2.5 (componant amplificatin factor (ASCE Table 13.5-1 or 13.6-1)) I p =1.00 (componant importance factor) R p =6.0 (componant response modification factor (ASCE Table 13.5-1 or 13.6-1)) z =10.00 ft (height in structure of point of attachment of componant with respect to the base.) h =10.00 ft (average roof height with respect to base. (z/h) <= 1.) Wp( Rp / Ip ) 11/7/2024 Fp = 0.4 ap SDS Wp (1 + 2 (z/h) )=0.51 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Prologis Hain JOB NO.: 1995 S Standard Ave & 1895 S Standard Ave ENGR.: Santa Ana, CA VERTICAL FORCES ON BEAM WIND GOVERNS USE: 3 Beams X1 2.67 ft W1 60 #X2 2.67 ft W1 W2 W3 …Wn W2 100 #X3 2.67 ft X1 X2 X3 …Xn-1 Xn W3 0 #X4 W4 0 #X5 L =8.01 ft W5 0 #X6 R1 R2 W6 0 #X7 W7 0 #X8 W8 0 #X9 W1 W9 0 #X10 RY1 W2 W10 0 #X11 … RY2 Wn RY1 =73.33 # RY2 =86.67 # mMax = 302.60 #-ft mMax = 3631.20 #-in Check Horizontal Beam for Bending fb =/= FB =>THEREFORE O.K. 3,631 #-in 0.290 in3 12,521 psi 33,000 psi 12,521 psi 11/7/2024 Structural Engineers 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 805.496.2100 • VinciSE.com W X 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Prologis Hain JOB NO.: 5140 E Santa Ana St ENGR.: Ontario, CA HORIZONTAL FORCES ON BEAM WIND GOVERNS USE: 3 Beams X1 F1 81 #X2 F1 F2 F3 …Fn F2 152 #X3 X1 X2 X3 …Xn-1 Xn F3 0 #X4 F4 0 #X5 L =8.00 ft F5 0 #X6 R1 R2 F6 0 #X7 F7 0 #X8 F8 0 #X9 F1 F9 0 #X10 RX1 F2 F10 0 #X11 … RX2 Fn RX1 =105.66 # RX2 =127.94 # mMax = 468.84 #-ft mMax = 5626.08 #-in Check Horizontal Beam for Bending fb =/= FB =>THEREFORE O.K. Check Bi-axial Bending 27,851.9 psi 33,000 psi THEREFORE O.K. +12521 psi =1.22 <1.33 33000 psi 5,626 #-in 0.202 in3 27,852 psi 33,000 psi 27,852 psi 11/7/2024 Structural Engineers 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 805.496.2100 • VinciSE.com F X 2.75 ft 2.50 ft 2.75 ft 0.00 ft 0.00 ft 0.00 ft 0.00 ft 0.00 ft 0.00 ft 0.00 ft 0 X 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Prologis Hain JOB NO.: 5140 E Santa Ana St ENGR.: Ontario, CA HORIZONTAL AND VERTICAL FORCES ON COLUMN WIND GOVERNS H =5.67 ft RY1+RY2 X1 0.33 ft R2 RX1+RX2 1.17 ft X1 RX 234 #X2 2.92 ft RX 234 #X3 1.75 ft RY1+RY2 2.75 ft X2 X4 RX1+RX2 X5 X6 1.75 ft X3 X7 R1 X8 X9 RX X10 R1 X11 … R2 Rn R1 =319.70 # R2 =147.49 # mMax = 356.93 #-ft mMax = 4283.15 #-in Check Column for Bending fb =/= FB =>THEREFORE O.K. Check Column for Axial Load fa =/=320 psi Fa =kl / r =4.5 ft x k /0.577 in =94 Fa ==20000 psi Check Unity 21,204 psi 33,000 psi THEREFORE O.K. <1.33 20000 psi (RY1 + RY2) x 2 0.555 in2 +320 psi =0.66 4,283 #-in 0.202 in3 21,204 psi 33,000 psi 21,204 psi 11/7/2024 Structural Engineers 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 805.496.2100 • VinciSE.com R X 1895 & 1995 S Standard Ave1/7/2025 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Santa Ana Distribution Center 1 Structural Engineers JOB NO.:22-3457 1995 S Standard Ave & 1895 S Standard Ave175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Axis Solar Power CHECK LATERAL FORCE ON SOLAR ARRAY 1. Check Horiz Beam to Post Use (1) 3/8" Diameter Bolt at Each Post Pullout FX =RX1 + RX2 =233.60 # 469 #<1325 #Therefore O.K. Shear FY =RY1 + RY2 =160.00 # 303 #<994 #Therefore O.K. 2. Check Brace in Compression Unistrut P1000 L =5.48 ft FBRACE =106 # x 5.48 ft / 4 ft =145 lbs r =0.577 KL/r =114 Fa =11.13 ksi Pa =11.13 ksi x 0.555 in2 =6.17715 K F = 145 #<6177 #Therefore O.K. 3. Check Brace Connection F = 145 #<994 #(3/8" bolt)Therefore O.K. 4. Check Attachment to Roof Connection Type:Wood Anchor Type:1/4 in Lag Bolt Embedment =2.50 in Tallow =218 # x CD X pen =872 # Vallow =210 # x CD =336 # Number of Anchors =2 ALL RESISTANCE BY BRACE h =FX = a =Prying Uplift = (F x h) / b = b =FY = Unity Check +133 lbs +0.431 < 1.00 Therefore O.K.336 lbs x 2 872 lbs 106 lbs 106 lbs 0.875 in 133 # 7.125 in 106 # 9.00 in 106 # 11/7/2024 1895 & 1995 S Standard Ave1/7/2025 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 1895 & 1995 S Standard Ave1/7/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 1895 & 1995 S Standard Ave1/7/2025 CARUSO TURLEY SCOTT structural engineers STRUCTURAL ENGINEERING EXPERTS PARTNERS Sandra Herd, SE, PE, LEED AP Thomas Morris, SE, LEED AP Richard Dahlmann, SE, PE Troy Turley, SE, PE, LEED AP Brady Notbohm, SE, PE PROFESSIONAL REGISTRATION 50 States Washington D.C. U.S. Virgin Islands Puerto Rico 1215 W. Rio Salado Pkwy. Suite 200 Tempe, AZ 85281 T: (480) 774-1700 F: (480) 774-1701 www.ctsaz.com Job No. 24-0242-3039.1 Sheet No. Cover By JEP/TET Date 6/5/24 CLIENT: 1600 Osgood Street Suite 2023 North Andover, MA 01845 PROJECT: Santa Ana Dist Ctrl 1 1895 S Standard Ave, Santa Ana, CA 92707, USA GENERAL INFORMATION: BUILDING CODE: 2022 CBC, ASCE 7-16 With SEAOC PV1-2012 and PV2-2017 TROY E.TURLEY 6/5/2024 1895 & 1995 S Standard Ave1/7/2025 CARUSO TURLEY SCOTT structural engineers STRUCTURAL ENGINEERING EXPERTS PARTNERS Sandra Herd, SE, PE, LEED AP Thomas Morris, SE, LEED AP Richard Dahlmann, SE, PE Troy Turley, SE, PE, LEED AP Brady Notbohm, SE, PE PROFESSIONAL REGISTRATION 50 States Washington D.C. U.S. Virgin Islands Puerto Rico 1215 W. Rio Salado Pkwy. Suite 200 Tempe, AZ 85281 T: (480) 774-1700 F: (480) 774-1701 www.ctsaz.com Date:June 5, 2024 Mr. Ryan Heil PanelClaw 1600 Osgood Street, Ste. 2023 North Andover, MA 01845 RE: Evaluation of PanelClaw system Project Name: Santa Ana Dist Ctrl 1 CTS Job No.: 24-0242-3039.1 Per the request of Ryan Heil at PanelClaw, CTS was asked to review the PanelClaw racking system with respect to the system’s ability to resist uplift and sliding caused by wind and seismic loads. Wind Evaluation: PanelClaw has provided CTS with wind tunnel testing performed by CPP, Inc. The system tested was the “clawFR 10 Degree” system. This system consists of photovoltaic panels installed at a 10 degree tilt onto support assemblies. The support assemblies consist of a support frame for the PV panels, wind deflectors and areas for additional mass/weight as required for the ballast loads. The wind tunnel testing was performed per Chapter 31 of ASCE 7-16. The parameters of the testing were a flat roof system in both Exposure B and C on a building with and without parapets. The testing has resulted in pressure and/or force coefficients that were applied to the velocity pressure qz in order to obtain the wind loads on the PV system. From the wind load results it is then possible to calculate the ballast loads required to resist the uplift and sliding forces. PanelClaw has provided CTS with the excel tool that was developed to obtain the uplift and sliding forces. CTS has reviewed this tool and the wind forces obtained to find that the amounts of ballast and mechanical attachments provided are within the values required. Furthermore, CTS agrees with the methodologies used to develop the uplift and sliding forces for the “clawFR 10 Degree” system per the wind tunnel testing results. Seismic Evaluation: CTS was asked to review the PanelClaw system to determine attachments required to resist seismic loading of the ballasted solar support system on the roof of the existing building. Following CBC Load Combination 16-16 and ASCE Section 2.4.5, the Dead Load value has been reduced by subtracting the vertical component of the seismic forces (0.6*D - 0.14Sds*D). The contribution of friction due to the component weight was not considered to resist lateral forces caused by seismic loads per ASCE Section 13.4. Utilizing this method, calculations have been provided for the number of mechanical attachments that are required to resist seismic forces that are applied to the system. 1895 & 1995 S Standard Ave1/7/2025 CARUSO TURLEY SCOTT structural engineers STRUCTURAL ENGINEERING EXPERTS PARTNERS Sandra Herd, SE, PE, LEED AP Thomas Morris, SE, LEED AP Richard Dahlmann, SE, PE Troy Turley, SE, PE, LEED AP Brady Notbohm, SE, PE PROFESSIONAL REGISTRATION 50 States Washington D.C. U.S. Virgin Islands Puerto Rico 1215 W. Rio Salado Pkwy. Suite 200 Tempe, AZ 85281 T: (480) 774-1700 F: (480) 774-1701 www.ctsaz.com Conclusion: Therefore, it has been determined that the system as provided by PanelClaw is sufficient to resist both wind and seismic loads at this project. Please contact CTS with any questions regarding this letter or attachments. Respectfully, Jakob Pongratz Troy Turley, SE, PE, LEED AP Structural Designer Partner TROY E.TURLEY 6/5/2024 1895 & 1995 S Standard Ave1/7/2025 Partner Name:Axis Solar Project Name:Santa Ana Dist Ctrl 1 Project Location:1895 S Standard Ave, Santa Ana, CA 92707, USA Racking System:clawFRplus 10 Degree Structural Calculations for Roof-Mounted Solar Array Submittal Release: Rev 1 Engineering Seal 05/24/2024 APPROVED FOR CONSTRUCTION TROY E.TURLEY 6/5/2024 1895 & 1995 S Standard Ave1/7/2025 Table of Contents Section:Page # 05/24/2024 APPROVED FOR CONSTRUCTION 2 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1.0 Project Information 4 1.1 General 4 1.2 Building Information 4 1.3 Structural Design Information 5 2.0 Snow Load 6 2.1 Snow Load Data 6 2.2 Snow Load Per Module 6 3.0 Wind Load 7 3.1 Wind Load Data 7 3.2 Roof / Array Zone Map 7 3.3 Wind Design Equations 7 4.0 Design Loads - Dead 8 4.1 Dead Load of the Arrays 8 5.0 Design Loads - Wind 9 5.1.1 Global Wind Uplift Summary Table:9 5.1.2 Global Wind Shear Summary Table:10 6.0 Design Loads - Downward 11 6.1 Downward Wind Load Calculation 11 6.2 Racking Dimensions for Point Loads 11 6.3 Point Load Summary 12 7.0 Design Loads - Seismic 13 7.1 Seismic Load Data 13 7.2 Seismic Design Equations 13 7.3 Lateral Seismic Force Check:14 7.4 Vertical Seismic Force Check:15 1895 & 1995 S Standard Ave1/7/2025 Appendix: A. Wind Tunnel Tests and Load Analysis for PANELCLAW ROOF MOUNT 10° TILT SOUTH-FACING, CPP Project 11828, Dated 15 March 2019. 05/24/2024 APPROVED FOR CONSTRUCTION 3 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 1.0 Project Information: 1.1 General: Project Name:Santa Ana Dist Ctrl 1 Project Location:1895 S Standard Ave, Santa Ana, CA 92707, USA Racking System:clawFRplus 10 Degree Module:HANWHA Q CELLS Q.PEAK DUO XL-G10.3/BFG 485 Module Weight:64.15 lbs. Module Tilt:9.76 deg. Module Width:41.14 in. Module Length:87.24 in. Module Area:24.93 sq.ft. Ballast Block Weight:32.60 lbs. 1.2 Building Information: Roof Name Height (ft.)Parapet Height (ft.) Roof 1 36 5.0 Sub-Array Name Pitch (deg.)Membrane Material Coeff. of Friction (μ) 1.1 1 TPO 0.80 1.2 1 TPO 0.80 1.3 1 TPO 0.80 1.4 1 TPO 0.80 05/24/2024 APPROVED FOR CONSTRUCTION 4 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 1.0 Project Information (Cont.): 1.3 Structural Design Information: ASCE Code:ASCE 7-16 Building Code:2022 CBC Risk Cat.:II Basic Wind Speed (V):95 mph Exposure Category:B Ground Snow Load (Pg):0 psf Is:1 Site Class:D Short Period Spectral Resp. (5%) (Ss):1.276 1s Spectral Response (5%) (S1):0.456 Ie:1 Ip:1 05/24/2024 APPROVED FOR CONSTRUCTION 5 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 2.0 Snow Load: Snow Calculations per ASCE 7-16, Chapter 7 2.1 Snow Load Data: Ground Snow Load (Pg)=0.00 psf (ASCE, Figure 7.2-1) Exposure Factor (Ce)=1 (ASCE, Table 7.3-1) Thermal Factor (Ct)=1.2 (ASCE, Table 7.3-2) Importance Factor (Is)=1 (ASCE, Table 1.5-2) Flat Roof Snow Load (Pf) =0.7*Pg*Ce*Ct*Is=0.00 psf (ASCE 7.3-1) Min Snow Load for Low Slope Roof =Pg*Is =0.00 psf (ASCE 7.3.4) Snow Load on Array (SLA) =0.00 psf SLA Fig. 2.1 - Uniform Roof Snow Load on Array 2.2 Snow Load Per Module: Snow Load per Module (SLM) =Module Projected Area SLA Where; Module Projected Area (Amp) = Module Area * Cos(Module Tilt) Where; Module Area =24.93 sq.ft. Module Tilt =9.76 deg. Amp =24.57 sq.ft. SLM =   Amp     SLA   = 0.00     lbs. 05/24/2024 APPROVED FOR CONSTRUCTION 6 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 3.0 Wind Load: Wind Analysis per ASCE 7-16- Wind Tunnel Procedure, Chapter 31 3.1 Wind Load Data: Basic Wind Speed (Vult) =95 mph (ASCE, Figure 26.5-1A) Exposure Category:B (ASCE, Sec. 26.7.3) Topographic Factor (Kzt) =1 (ASCE, Fig. 26.8-1) Directionality Factor (Kd) =0.85 (ASCE, Table 26.6-1) Exposure Coefficient (Kz) =0.74 (ASCE, Table 26.10-1) Ground Elevation Factor (Ke) =1.00 (ASCE, Table 26.9-1) Velocity Pressure (qz) =0.00256*Kz*Kzt*Kd*Ke*V^2 =14.45 psf (ASCE, Eqn. 26.10-1) 3.2 Roof / Array Zone Map: Figure 3-1. South corner zones – 90-180° wind directions Figure 3-2. North corner zones – 0- 90° wind direction Roof Zone Map Dimensions per CPP Wind Tunnel Study Height (ft.)LB* (ft.)Velocity Pressure (qz) (psf) 36 36.00 14.45 *LB = Characteristic length per wind tunnel study 3.3 Wind Design Equations: FL = qz Aref GCL FL = sum of lift on panel and deflector. FD = qz Aref GCD FD = sum of drag on panel and deflector. FL - D Companion = qz Aref GCL - D Companion FL - D Companion = The accompanying uplift corresponding to maximum drag. Where qz = Velocity Pressure (Ref. Section 3.1, Wind Load) Aref = Module Area (Ref. Section 1.1, General) GCL GCD , GCL-D Companion= Vary and related to wind zone map (Proprietary Wind Tunnel Coefficients) 05/24/2024 APPROVED FOR CONSTRUCTION 7 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 4.0 Design Loads - Dead: There are two categories of dead load used to perform the structural analysis of the PanelClaw racking system; Dead Load of the Array (DLA) and Dead Load of the Components (DLC). DLA is defined as the weight of the entire array including all of the system components and total ballast used on the array. DLC is defined as the weight of the modules and the racking components within an array. The DLC does not include the ballast used to resist loads on this array. 4.1 Dead Load of the Arrays: Array Information Results Sub- Array Name Number of Modules DLC (lbs.) DLA (lbs.) DLC (lbs.)/module Sub- Array Area (ft.^2) Sub-Array Roof Pressure (DLC) (psf) Sub-Array Roof Pressure (DLA) (psf) Max Allowable Pressure on Roof (psf) Acceptable? 1.1 329 26,643 31,077 81 10,765 2.47 2.89 100.00 Yes 1.2 258 20,990 24,544 81 8,415 2.49 2.92 100.00 Yes 1.3 396 31,902 36,075 81 12,994 2.46 2.78 100.00 Yes 1.4 326 26,313 29,997 81 10,681 2.46 2.81 100.00 Yes Total:  1309 105,849 lbs.121,693 lbs. *Racking component weight range between 13 to 15 pounds per module Table 4.1 - Array Dead Loads and Roof Pressures 05/24/2024 APPROVED FOR CONSTRUCTION 8 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 5.0 Design Loads - Wind: 5.1.1 Global Wind Uplift Summary Table: The necessity to add mechanical attachments can arise for several reasons. Building code requirements, roof load limits and array shape all may come into play when determining their need. The table below provides the mechanical attachment requirements for each sub-array within this project.  Applied Load Resisting Load Code Check Sub- Array Name FL = Total Wind Uplift (lbs.) DL = Total Dead Load (lbs.) Maximum Allowable Mechanical Attachment Strength (lbs.) Total MA Capacity (lbs.) Calculated Factor of Safety* Check 1.1 23,732 31,077 525 4,440 2.49 OK 1.2 18,781 24,544 525 3,520 2.49 OK 1.3 27,158 36,075 525 6,929 2.64 OK 1.4 22,403 29,997 525 5,405 2.63 OK Total:92,074 lbs.121,693 lbs. 20,294 lbs. Table 5.1 Summary of Mechanical Attachment Requirements * Back calculated factor of safety provided to determine factor of safety applied to dead load in lieu of 0.6 in ASCE 7-16 equation 7, BACK CALCULATED FACTOR OF SAFETY = (DEAD LOAD+MECHANICAL ATTACHMENT)/(.6)WIND LOAD 05/24/2024 APPROVED FOR CONSTRUCTION 9 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 5.0 Design Loads - Wind (Cont.): 5.1.2 Global Wind Shear Summary Table: Mechanical attachments may be required for several reasons including building code, roof load limits and array shape. The table below provides the mechanical attachment requirements for each sub-array within this project.  Applied Load Resisting Load Code Check Sub- Array Name FL-D = Wind Uplift (lbs.) FD = Wind Drag (lbs.) DL = Total Dead Load (lbs.) Maximum Allowable Mechanical Attachment Strength (lbs.) Total MA Capacity (lbs.) Check Calculated Factor of Safety* Check 1.1 9,489 3,261 31,077 650 11,050 5.18 OK 1.2 7,876 2,807 24,544 650 9,100 4.92 OK 1.3 10,642 3,607 36,075 650 13,000 5.40 OK 1.4 9,176 3,093 29,997 650 10,400 5.16 OK Total:37,183 lbs.12,768 lbs.121,693  43,550 lbs. Table 5.2 Summary of Mechanical Attachment Requirements * Back calculated factor of safety provided to determine factor of safety applied to dead load in lieu of 0.6 in ASCE7 equation 7, BACK CALCULATED FACTOR OF SAFETY = (DEAD LOAD+MECHANICAL ATTACHMENT)/(((.6)WIND DRAG /FRICTION)+(.6)WIND UPLIFT) 05/24/2024 APPROVED FOR CONSTRUCTION 10 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 6.0 Design Loads - Downward: 6.1 Downward Wind Load Calculation: WLin = qz * Am * GCP * cos θ Where: qz =14.45 psf (Ref. Section 3.1, Wind Load Data) Am =24.93 sq.ft.(Single Module Area)(Ref. Section 1.1, General Project Information) θ =9.76 deg.(Ref. Section 1.1, General Project Information) GCP =1.13 (Inward)(Proprietary Wind Tunnel Data) GCP =0.30 (Inward with snow)(ASCE 7-16 figure 30.3-5A) WLin(no snow) = 401 lbs./module WLin(with snow) = 107 lbs./module Contact Base by Location:                                                        Contact Pad by Information: 1 =South Distance Between C.C. outer Pads =18 in. 2 =Interior Typical Pad Area =9 sq.in. 3 =2nd from North 4 =North 6.2 Racking Dimensions for Point Loads: Inter-Module Support spacing (S) = 46.61 in. Inter-Column Support Spacing (L) = 41.34 in. Fig. 6.1 Typical Array Plan View (Section A-A) on Next Page 05/24/2024 APPROVED FOR CONSTRUCTION 11 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 6.0 Design Loads - Downward (Cont.): 6.2 Racking Dimensions for Point Loads (Cont.): Fig. 6.2 Section A-A 6.3 Point Load Summary:Notes: DLsys = 81 lbs./module -Base 2 repeat for larger width arrays. Total DL = (Varies on location and ballast quantity) SLm = 0 lbs./module WLin (no snow) = 401 lbs./module WLin (with snow) = 107 lbs./module Max Total Load Per Base (lbs.) load combinations (ASD) Location Base DL + Snow DL + 0.6 X Wlin DL + 0.75 X SLm + 0.75(0.6 X WLin) South 1 27 87 39 Interior 2 58 179 82 2nd From North 3 55 176 79 North 4 35 95 47 Table 6.1-A Max Total Load per Base (lbs.) Max Contact Pressure Table Per Base (psi) load combinations (ASD)# of Pads Location Base DL + Snow DL + 0.6 X Wlin DL + 0.75 X SLm + 0.75(0.6 X WLin) South 1 1 5 2 Interior 2 3 10 4 2nd From North 3 3 10 4 2 North 4 2 5 3 South 1 1 2 1 Interior 2 2 5 2 2nd From North 3 1 5 2 4 North 4 1 3 1 Table 6.1-B Max Point Load Summary (psi) 05/24/2024 APPROVED FOR CONSTRUCTION 12 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 7.0 Design Loads - Seismic: Seismic Calculations per ASCE 7-16, Chapter 11 - Seismic Design Criteria Chapter 13 - Requirements for Nonstructural Components 7.1 Seismic Load Data: Site Class :D (Ref. Project Information) Seismic Design Category :D (ASCE, Tables 11.6-1 and 11.6-2) Short Period Spectral Resp. (5%) (Ss) :1.276 (Ref. Project Information) 1s Spectral Response (5%) (S1) :0.456 (Ref. Project Information) Bldg. Seismic Imp. Factor (Ie) =1 (ASCE, Table 1.5-2) Site Coefficient (Fa) =1.2 (ASCE, Table 11.4-1) Site Coefficient (Fv) =1.8 (ASCE, Table 11.4-2) Adj. MCE Spec. Resp. (Short) (Sms) =Fa*Ss =1.531 (ASCE, Eqn. 11.4-1) Adj. MCE Spec. Resp. (1 sec.) (Sm1) =Fv*S1 =0.841 (ASCE, Eqn. 11.4-2) Short Period Spectral Response (Sds) =2/3(Sms) =1.021 (ASCE, Eqn. 11.4-3) One Second Spectral Response (Sd1) =2/3(Sm1) =0.561 (ASCE, Eqn. 11.4-4) Component Seismic Imp. Factor (Ip) =1 (ASCE, Sec. 13.1.3) Repsonse Modification Factor (Rp) =2.5 (ASCE, Table 13.6-1) Amplification Factor (ap) =1 (ASCE, Table 13.6-1) 7.2 Seismic Design Equations: * Frictional resistance due to the components weight may not be used to resist lateral forces caused by seismic loads. 05/24/2024 APPROVED FOR CONSTRUCTION 13 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 7.0 Design Loads - Seismic (Cont.): 7.3 Lateral Seismic Force Check: The necessity to add mechanical attachments can arise for several reasons. Building code requirements, roof load limits and array shape all may come into play when determining their need. The table below provides the mechanical attachment requirements for each sub-array within this project. Nomenclature: WP = Sub-Array Weight FPL = Lateral Seismic Force FRL = Lateral Seismic Resisting Force Array Information Lateral Force Verification Results Sub- Array Name WP (lbs.) FPL (lbs.) FRL (lbs.) 0.7 FPL - FRL (lbs.) MA's Required Total MA Capacity (lbs.) MA's Provided Acceptable 1.1 31,077 15,227 0 10,659 17 11,050 17 Yes 1.2 24,544 12,026 0 8,418 13 9,100 14 Yes 1.3 36,075 17,676 0 12,373 20 13,000 20 Yes 1.4 29,997 14,698 0 10,289 16 10,400 16 Yes Totals:121,693 lbs 59,627 lbs.0 lbs.41,739 lbs.66 43,550 67 Table 7.1 -Summary of Mechanical Attachment Requirements * MA's Required = 0.7 FPL-FRL/MA strength 05/24/2024 APPROVED FOR CONSTRUCTION 14 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 7.0 Design Loads - Seismic (Cont.): 7.4 Vertical Seismic Force Check: Mechanical attachments may be required for several reasons including building code, roof load limits and array shape. The table below provides the mechanical attachment requirements for each sub-array within this project. Nomenclature: WP = Sub-Array Weight FPV = Vertical Seismic Force FRV = Vertical Seismic Resisting Force Array Information Vertical Force Verification Results Sub- Array Name WP (lbs.) FPV (lbs.) FRV (lbs.) 0.7 FPV - FRV (lbs.) MA's Required Total MA Capacity (lbs.) Total MA's Provided Acceptable 1.1 31,077 6,345 18,646 -14,205 0 4,440 17 Yes 1.2 24,544 5,011 14,726 -11,219 0 3,520 14 Yes 1.3 36,075 7,365 21,645 -16,489 0 6,929 20 Yes 1.4 29,997 6,124 17,998 -13,711 0 5,405 16 Yes Total: 121,693 lbs.24,845 lbs.73,016 lbs.-55,624 lbs.0 20,294 67 Table7.2 - Summary of Mechanical Attachment Requirements * MA's Required = 0.7 FPV - FRV/MA strength 05/24/2024 APPROVED FOR CONSTRUCTION 15 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 Appendix A Appendix A16 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 Appendix A17 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 Appendix A18 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 Appendix A19 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 Appendix A20 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 Appendix A21 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 Appendix A22 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 Appendix B Appendix B 23 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 Appendix B 24 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 Appendix B 25 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 Appendix B 26 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 Appendix B 27 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 Appendix B 28 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 Appendix B 29 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1895 & 1995 S Standard Ave1/7/2025 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 1895 & 1995 S Standard Ave1/7/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 1895 & 1995 S Standard Ave1/7/2025 2 (1) #6 AWG CU THWN-2 EGC (2) #10 AWG CU PV WIRE DISTANCE: 100 FT, 0.53% VDROP 3 (1) #6 AWG CU THWN-2 EGC (6) #10 AWG CU PV WIRE FILL: 0.3397 IN^2 1" IMC ON STRUCTURES, 39% FILL DISTANCE: 175 FT, 0.92% VDROP 4.1 (1) #6 AWG CU THWN-2 EGC (1) #4 AWG CU THWN-2 NEUT (3) #3/O AWG CU THWN-2 FILL: 0.9368 IN^2 2" EMT ON STRUCTURES, 28% FILL DISTANCE: 10 FT, 0.05% VDROP 4.2 (1) #6 AWG CU THWN-2 EGC (1) #6 AWG CU THWN-2 NEUT (3) #1/O AWG CU THWN-2 FILL: 0.6579 IN^2 1.5" EMT ON STRUCTURES, 32% FILL DISTANCE: 10 FT, 0.05% VDROP 6 (1) #2/O AWG CU THWN-2 EGC (1) #250 MCM CU THWN-2 NEUT (3) #250 MCM CU THWN-2 (2) PARALLEL RUNS (2) CONDUITS, IN EACH: FILL: 1.7038 IN^2 2.5" IMC ON STRUCTURES, 29% FILL DISTANCE: 15 FT, 0.06% VDROP 1 (1) #6 AWG CU THWN-2 EGC (2) #10 AWG CU PV WIRE DISTANCE: 1 FT, 0.03% VDROP 5.1 (1) #2 AWG CU THWN-2 EGC (1) #1/O AWG CU THWN-2 NEUT (3) #250 MCM CU THWN-2 (2) PARALLEL RUNS (2) CONDUITS, IN EACH: FILL: 1.4923 IN^2 2.5" EMT ON STRUCTURES, 25% FILL DISTANCE: 125 FT, 0.52% VDROP (N) PV AC DISCONNECT 1 600VAC, 3P, 800A, NEMA 3R W/ 500A FUSES, 65 kAIC VISIBLE / LOCKABLE FOR UTILITY OPERATION (TO BECOME MAIN SINGLE POINT OF DISCONNECT ONCE NEW FUTURE MAIN SWITCHGEAR IS INSTALLED) G G INV JBOX TYP DC DC INV 1 - 120 kW STRINGS 1 -3 110 MODULES 1 120 JBOX TYP DC DC INV 1 - 120 kW STRINGS 4-6 110 MODULES (N) 200A/3P 500A X1 TO SYNGERGY UNIT 138 (N) 150A/3P G G INV JBOX TYP DC DC INV 3 - 80 kW STRINGS 1 -3 108 MODULES 3 80 JBOX TYP DC DC INV 3 - 80 kW STRINGS 4-6 113 MODULES PER MODULE PER STRING JBOX TYP DC DC INV 1 - 120 kW STRINGS 7-9 110 MODULES G G INV JBOX TYP DC DC INV 2 - 120 kW STRINGS 1 -3 108 MODULES 2 120 JBOX TYP DC DC INV 2 - 120 kW STRINGS 4-6 108 MODULES JBOX TYP DC DC INV 2 - 120 kW STRINGS 7-9 110 MODULES (N) 200A/3P FAULT CURRENT CALCULATIONS: *PER PLD SPEC 11A, CONFIRM ALUMINUM IS APPROVED WITH OWNER PRIOR TO INSTALLATION. FINAL 24" CONDUIT LENGTH TO INVERTER IS LFMC TO FACILITATE FUTURE INVERTER REPLACEMENT. FINAL 24" CONDUIT LENGTH TO INVERTER IS LFMC TO FACILITATE FUTURE INVERTER REPLACEMENT. FINAL 24" CONDUIT LENGTH TO INVERTER IS LFMC TO FACILITATE FUTURE INVERTER REPLACEMENT. NOTES: 1. PROVIDE CONTINUOUS PATH FOR GROUND CONDUCTOR FROM THE INVERTER TO THE EXISTING MAIN SERVICE SWITCHBOARD GROUND BUS. GROUNDING ELECTRODE CONDUCTOR TO SERVE AS EQUIPMENT GROUND. PROVIDE LAY-IN LUGS TO BOND ALL EQUIPMENT ALONG THIS PATH TO THE GROUNDING ELECTRODE CONDUCTOR TO ALLOW FOR CONTINUOUS RUN. TUSTIN MCAF: COLD DESIGN TEMP = 2°C HOT DESIGN TEMP = 31°C PROJECT TOTAL TOTAL SYSTEM SIZE: 425.345 kW DC, 392.445 kW ACcec PANEL SPECS: (877) HANWHA Q CELLS, Q.PEAK DUO XL-G10.3/BFG 485 MODULE AMPERAGE: 10.63 IMP, 11.16 ISC MODULE VOLTAGE: 45.63 VMP, 53.63 VOC TEMP. COEFFICIENTS OF Voc: -0.27%/°C STC: 485W, PTC: 454.3 W INVERTER SPECS: (2) SOLAREDGE TECHNOLOGIES, SE120KUS [480V] 277/480V, 3PH, 4W, MAX OUTPUT CURRENT = 144.3A CEC WEIGHTED EFFICIENCEY: 98.5% (1) SOLAREDGE TECHNOLOGIES, SE80KUS [480V] 277/480V, 3PH, 4W, MAX OUTPUT CURRENT = 96.5A CEC WEIGHTED EFFICIENCEY: 98.5% OPTIMIZER/RAPID SHUTDOWN SPECS: (439) SOLAREDGE PER P1101 OPTIMIZER RATED INPUT DC POWER = 1101W MAX OUTPUT CURRENT = 18A MAXIMUM OUTPUT VOLTAGE = 80V MAX SYSTEM VOLTAGE = 1,000V SEE SPEC SHEET FOR ELECTRICAL PARAMETERS AND WARRANTY INFO KEY PANELS PER STRING STRINGS PER SYNERGY UNIT ARRAY DC DC SOLAREDGE P1101 POWER OPTIMIZER (2) MODULES PER X2 TO SYNERGY UNIT X XX X1 TO SYNERGY UNITXXX (N) 800A PV SUB 1, 277/480V, 3PH, 4W MLO, NEMA 3R, 42 kAIC INTEGRATED DC DISCONNECT, 1000VDC INVERTER NUMBER INVERTER SIZE (kW) X G G INV XX X2X3 COPPER OPTION: COPPER OPTION: ETHERNET CAT5E/CAT6 (1" EMT) SERIAL/RS485 (1" EMT) SE R I A L / R S 4 8 5 (1 " E M T ) DA I S Y C H A I N I N V E R T E R S (N) DAS-1 MONITORING CONTROL PANEL WITH REVENUE GRADE METER & SOLAREDGE COMMUNICATIONS GATEWAY. (N) METER 1 FACILITY CONSUMPTION METERSERIAL/RS485 24VDC 4W, 1G #12 AWG CU THWN-2 (1" EMT) (N) 15A/3P (N) 15A/2P 3W, 1G #12 AWG CU THWN-2 (1" EMT) 4W, 1G #12 AWG CU THWN-2 (1" EMT) X2 TO SYNGERGY UNIT 1 36 X1 TO SYNGERGY UNIT 238 X2 TO SYNGERGY UNIT 2 36 X1 TO SYNGERGY UNIT 338 X2 TO SYNGERGY UNIT 3 36 X3 TO SYNGERGY UNIT 136 X3 TO SYNGERGY UNIT 236 X3 TO SYNGERGY UNIT 1 36 X2 TO SYNGERGY UNIT 238 SE R I A L / R S 4 8 5 (1 " E M T ) DA I S Y C H A I N I N V E R T E R S PER INPUT: G X1 TO SYNGERGY UNIT 2 37 X1 TO SYNGERGY UNIT 338 X2 TO SYNGERGY UNIT 3 36 LINE SIDE TAP NEC 705.12(A)(1) (N) 15A/3P MAX VOLTAGE DROP MODULE TO OPTIMIZER = 0.03% OPTIMIZER TO JBOX = 0.53% JBOX TO INVERTER = 0.92% INVERTER TO COMBINER = 0.06% COMBINER TO AC DISCONENCT = 0.25% AC DISCONENCT TO MAIN SERVICE = 0.03% TOTAL = 1.82% EX T E R I O R E L E C T R I C A L R O O M IN T E R I O R E L E C T R I C A L R O O M DC CONDUIT SCHEDULE: (2) #10 AWG CU PV WIRE PER STRING (1) #10 AWG CU THWN-2 EGC PER CONDUIT #STRINGS FILL IMC SIZE/FILL % EMT SIZE/FILL% PVC SIZE/FILL% 1 0.1273 0.75"/22% 0.75"/24% 0.75"/31% 2 0.2335 1"/24% 1"/27% 1"/34% 3 0.3397 1"/35% 1"/39% 1.25"/27% 4 0.4459 1.25"/27% 1.25"/30% 1.25"/36% 35% 3xCT ROGOWSKI CT-M1 X1 MMMM 4000A BUS (F) 2000A/3P MAIN W/GFPGFP (F) GROUND SYSTEM GRD (F) MAIN SWITCHBOARD "MSA" 480/277V, 3PH, 4W, 100kAIC (F) EV CHARGERS (F) EV CHARGERS (E) PANEL "HHA" (F) 600A/3P MAIN (F) 600A/3P MAIN(F) 200AS 200AF 3P 2000A BUS 2000A BUS (E) MAIN SWITCHBOARD "MS-B" 480/277V, 3PH, 4W, 65kAIC CIRCUIT TO BE ABANDONED IN FUTURE (F)600A BUS METER FOR 1995 TO BE REMOVED BY UTILITY IN THE FUTURE (E) 600AF (E) 600AT, 3P (E) DISTRIBUTION PANEL "DP1" METER FOR 1801 TO BE REMOVED BY UTILITY IN THE FUTURE METER FOR HHA TO BE REMOVED BY UTILITY IN THE FUTURE (E) 800AF (E) 400AT, 3P (F) 800AT, 3P (E) DISTRIBUTION PANEL "DP2" METER FOR 1895 TO BE REMOVED BY UTILITY IN THE FUTURE (E) 800AS (E) 600AF, 3P UTILITY SERVICE (E) GROUND SYSTEM GRD (E) MISC. LOADS 1895 S STANDARD AVE SANTA ANA, CA 92707 METER# 259000-097541 1995 S STANDARD AVE SANTA ANA, CA 92707 METER#259000-036083 (F) CONDUIT & CONDUCTORS FROM SEPARATE PERMIT NOTE: FUTURE EQUIPMENT (F) TO BE INSTALLED AS PART OF A SEPARATE PERMIT. THIS EQUIPMENT IS SHOWN FOR CLARITY ONLY. SUBJECT TO CHANGE ON OTHER PERMIT. RO O F T O P EX T E R I O R E L E C T R I C A L R O O M (3) TWISTED PAIR LEADS (1" EMT) (N) WEATHER STATION 1 SERIAL/RS485 24VDC (F) FUTURE EQUIPMENT (N) SPACE FOR (2) 150A/3P FOR FUTURE COMBINED SYSTEM (F) 1995 S STANDARD AVE METER UT I L I T Y CU S T O M E R (E) 800A SECTION (E) 800A SECTION NOTE: CABLE LIMITERS TO BE PROVIDED IF TAP LENGTH IS GREATER THAN3 3 3 3 3 THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 2/ 1 4 / 2 0 2 5 1 2 : 5 0 : 3 6 P M Ut i l i t y C u s t o m e r N a m e : P r o l o g i s L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 1 9 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-9.1 Si n g l e L i n e D i a g r a m S y s t e m 1 SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 12" = 1'-0"1 Single Line Diagram System 1 WIRING CHART Ca l l o u t # Am p s I s c NE C M u l t Am p s M a x Pa r a l l e l R u n s Nu m b e r C o n d u c t o r s Si z e C o n d u c t o r Co n d u c t o r M a t l In s u l a t i o n C o n d u c t o r Si z e N e u t r a l Si z e G r o u n d Co n d u i t Q t y Wi r e T e m p R a t i n g Wi r e A m b T e m p Wi r e R o o f T e m p Wi r e T e m p T o t a l Co n d u c t o r s C u r r e n t C a r r y i n g . . 1 11.16 1.56 17 1 2 #10 AWG CU PV WIRE NA #6 AWG 1 90 31 0 31 2 2 18 1.25 23 1 2 #10 AWG CU PV WIRE NA #6 AWG 1 90 31 0 31 2 3 18 1.25 23 1 6 #10 AWG CU PV WIRE NA #6 AWG 1 90 31 0 31 6 4.1 144.3 1.25 180 1 3 #3/O AWG CU THWN-2 #4 AWG #6 AWG 1 90 31 0 31 3 4.2 96.5 1.25 121 1 3 #1/O AWG CU THWN-2 #6 AWG #6 AWG 1 90 31 0 31 3 5.1 385.1 1.25 481 2 3 #250 MCM CU THWN-2 #1/O AWG #2 AWG 2 90 30 0 30 3 6 385.1 1.25 481 2 3 #250 MCM CU THWN-2 #250 MCM #2/O AWG 2 90 31 0 31 3 WIRE RATING CHART Pa r a l l e l R u n s Wi r e A m p R a t i n g Wi r e T e m p D e r a t e Wi r e C o n d u c t o r D e r a t e Derated Wire Rating <= Amps Max . . 1 40 0.96 1 1 X 40A X 0.96 X 1 = 38 >= 17 1 40 0.96 1 1 X 40A X 0.96 X 1 = 38 >= 23 1 40 0.96 0.8 1 X 40A X 0.96 X 0.8 = 31 >= 23 1 225 0.96 1 1 X 225A X 0.96 X 1 = 216 >= 180 1 170 0.96 1 1 X 170A X 0.96 X 1 = 163 >= 121 2 290 1 1 2 X 290A X 1 X 1 = 580 >= 481 2 290 0.96 1 2 X 290A X 0.96 X 1 = 557 >= 481 TERMINATION... Te r m T e m p R a t i n g Term Amp Rating >=Amps Max . . 60 30 >=17 60 30 >=23 60 30 >=23 75 200 >=180 75 150 >=121 75 510 >=481 75 510 >=481 VOLTAGE DROP CHART Vd r o p A m p s I m p Vd r o p V m p Vd r o p D i s t a n c e Vd r o p P e r c e n t . . 10.63 91.26 1 0.03 18 850 100 0.53 18 850 175 0.92 144.3 480 10 0.05 96.5 480 10 0.05 385.1 480 125 0.52 385.1 480 15 0.06 * * NOTE: ALL TERMINATIONS TO BE RATED TO 75°C OR MORE Ut i l i t y M e t e r C u s t o m e r A d d r e s s : 1 9 9 5 S S T A N D A R D , A V E S A N T A A N A , C A 9 2 7 0 7 Ut i l i t y C u s t o m e r N a m e : P r o l o g i s L o g i s t i c S e r v I n c . No . De sc ri pt ion Da t e 3 C o n st . Ch g # 1 2/ 1 4 / 2 5 Revision to 20184604-05 (issued on 12/23/24) Revision 1 #'s 20185423-24 APPROVALS: ELECT - M. Smith 1895 & 1995 S Standard Ave5/5/2025 2 (1) #6 AWG CU THWN-2 EGC (2) #10 AWG CU PV WIRE DISTANCE: 100 FT, 0.53% VDROP 3 (1) #6 AWG CU THWN-2 EGC (6) #10 AWG CU PV WIRE FILL: 0.3397 IN^2 1" IMC ON STRUCTURES, 39% FILL DISTANCE: 175 FT, 0.92% VDROP 5.1 (1) #4 AWG CU THWN-2 EGC (1) #2 AWG CU THWN-2 NEUT (3) #250 MCM CU THWN-2 FILL: 1.3892 IN^2 2.5" EMT ON STRUCTURES, 24% FILL DISTANCE: 125 FT, 0.52% VDROP 6 (1) #2 AWG CU THWN-2 EGC (1) #250 MCM CU THWN-2 NEUT (3) #250 MCM CU THWN-2 FILL: 1.6704 IN^2 2.5" IMC ON STRUCTURES, 29% FILL DISTANCE: 15 FT, 0.06% VDROP 4 (1) #6 AWG CU THWN-2 EGC (1) #6 AWG CU THWN-2 NEUT (3) #1/O AWG CU THWN-2 FILL: 0.6579 IN^2 1.5" EMT ON STRUCTURES, 32% FILL DISTANCE: 10 FT, 0.05% VDROP 1 (1) #6 AWG CU THWN-2 EGC (2) #10 AWG CU PV WIRE DISTANCE: 1 FT, 0.03% VDROP INV JBOX TYP DC DC INV 4 - 80 kW STRINGS 1 -3 108 MODULES 4 JBOX TYP DC DC INV 4 - 80 kW STRINGS 4-6 108 MODULES X3 TO SYNGERGY UNIT 136 PER MODULE PER STRING INV JBOX TYP DC DC INV 5 - 80 kW STRINGS 1 -3 108 MODULES 5 JBOX TYP DC DC INV 5 - 80 kW STRINGS 4-6 108 MODULES FAULT CURRENT CALCULATIONS: *PER PLD SPEC 11A, CONFIRM ALUMINUM IS APPROVED WITH OWNER PRIOR TO INSTALLATION. FINAL 24" CONDUIT LENGTH TO INVERTER IS LFMC TO FACILITATE FUTURE INVERTER REPLACEMENT. FINAL 24" CONDUIT LENGTH TO INVERTER IS LFMC TO FACILITATE FUTURE INVERTER REPLACEMENT. NOTES: 1. PROVIDE CONTINUOUS PATH FOR GROUND CONDUCTOR FROM THE INVERTER TO THE EXISTING MAIN SERVICE SWITCHBOARD GROUND BUS. GROUNDING ELECTRODE CONDUCTOR TO SERVE AS EQUIPMENT GROUND. PROVIDE LAY-IN LUGS TO BOND ALL EQUIPMENT ALONG THIS PATH TO THE GROUNDING ELECTRODE CONDUCTOR TO ALLOW FOR CONTINUOUS RUN. TUSTIN MCAF: COLD DESIGN TEMP = 2°C HOT DESIGN TEMP = 31°C PROJECT TOTAL TOTAL SYSTEM SIZE: 209.52 kW DC, 193.313 kW ACcec PANEL SPECS: (432) HANWHA Q CELLS, Q.PEAK DUO XL-G10.3/BFG 485 MODULE AMPERAGE: 10.63 IMP, 11.16 ISC MODULE VOLTAGE: 45.63 VMP, 53.63 VOC TEMP. COEFFICIENTS OF Voc: -0.27%/°C STC: 485W, PTC: 454.3 W INVERTER SPECS: (2) SOLAREDGE TECHNOLOGIES, SE80KUS [480V] 277/480V, 3PH, 4W, MAX OUTPUT CURRENT = 96.5A CEC WEIGHTED EFFICIENCEY: 98.5% OPTIMIZER/RAPID SHUTDOWN SPECS: (216) SOLAREDGE PER P1101 OPTIMIZER RATED INPUT DC POWER = 1101W MAX OUTPUT CURRENT = 18A MAXIMUM OUTPUT VOLTAGE = 80V MAX SYSTEM VOLTAGE = 1,000V SEE SPEC SHEET FOR ELECTRICAL PARAMETERS AND WARRANTY INFO KEY PANELS PER STRING STRINGS PER SYNERGY UNIT ARRAY DC DC SOLAREDGE P1101 POWER OPTIMIZER (2) MODULES PER X2 TO SYNERGY UNIT X XX X1 TO SYNERGY UNITXXX INTEGRATED DC DISCONNECT, 1000VDC INVERTER NUMBER INVERTER SIZE (kW) X G G INV XX COPPER OPTION: ETHERNET CAT5E/CAT6 (1" EMT) SERIAL/RS485 (1" EMT) SE R I A L / R S 4 8 5 (1 " E M T ) DA I S Y C H A I N I N V E R T E R S G G80 G G80 X3 TO SYNGERGY UNIT 236 X3 TO SYNGERGY UNIT 136 X3 TO SYNGERGY UNIT 236 PER INPUT: MAX VOLTAGE DROP MODULE TO OPTIMIZER = 0.03% OPTIMIZER TO JBOX = 0.53% JBOX TO INVERTER = 0.92% INVERTER TO COMBINER = 0.06% COMBINER TO AC DISCONENCT = 0.61% AC DISCONENCT TO MAIN SERVICE = 0.06% TOTAL = 2.21% (N) PV AC DISCONNECT 2 600VAC, 3P, 400A MIN, NEMA 3R W/ 250A FUSES, 65 kAIC VISIBLE / LOCKABLE FOR UTILITY OPERATION (TO BE REMOVED WHEN SYSTEMS ARE COMBINED IN THE FUTURE) (N) 150A/3P 250A(N) 150A/3P (N) 250A MIN PV SUB 2, 277/480V, 3PH, 4W MLO, NEMA 3R, 42 kAIC RO O F T O P EX T E R I O R E L E C T R I C A L R O O M X2X3 COPPER OPTION: (N) DAS-2 MONITORING CONTROL PANEL WITH REVENUE GRADE METER & SOLAREDGE COMMUNICATIONS GATEWAY. (N) METER 2 FACILITY CONSUMPTION METERSERIAL/RS485 24VDC 4W, 1G #12 AWG CU THWN-2 (1" EMT) 3xCT ROGOWSKI CT-M1 (3) TWISTED PAIR LEADS (1" EMT) (N) 15A/3P (N) 15A/2P 3W, 1G #12 AWG CU THWN-2 (1" EMT) 4W, 1G #12 AWG CU THWN-2 (1" EMT) G #1/0 AWG CU MAIN BONDING JUMPER X1 LINE SIDE TAP NEC 705.12(A)(1) (N) 15A/3P EX T E R I O R E L E C T R I C A L R O O M IN T E R I O R E L E C T R I C A L R O O M M MMM 4000A BUS (F) 2000A/3P MAIN W/GFPGFP (F) GROUND SYSTEM GRD (F) MAIN SWITCHBOARD "MSA" 480/277V, 3PH, 4W, 100kAIC (F) EV CHARGERS (F) EV CHARGERS (E) PANEL "HHA" (F) 600A/3P MAIN (F) 600A/3P MAIN(F) 200AS 200AF 3P 2000A BUS 2000A BUS (E) MAIN SWITCHBOARD "MS-B" 480/277V, 3PH, 4W, 65kAIC CIRCUIT TO BE ABANDONED IN FUTURE (F)600A BUS (E) 600AF (E) 600AT, 3P (E) DISTRIBUTION PANEL "DP1" (E) 800AF (E) 400AT, 3P (F) 800AT, 3P (E) DISTRIBUTION PANEL "DP2" (E) 800AS (E) 600AF, 3P UTILITY SERVICE (E) GROUND SYSTEM GRD (E) MISC. LOADS 1895 S STANDARD AVE SANTA ANA, CA 92707 METER# 259000-097541 1995 S STANDARD AVE SANTA ANA, CA 92707 METER#259000-036083 (F) CONDUIT & CONDUCTORS FROM SEPARATE PERMIT NOTE: FUTURE EQUIPMENT (F) TO BE INSTALLED AS PART OF A SEPARATE PERMIT. THIS EQUIPMENT IS SHOWN FOR CLARITY ONLY. SUBJECT TO CHANGE ON OTHER PERMIT. (F) FUTURE EQUIPMENT (F) 1995 S STANDARD AVE METER METER FOR 1995 TO BE REMOVED BY UTILITY IN THE FUTURE METER FOR 1801 TO BE REMOVED BY UTILITY IN THE FUTURE METER FOR HHA TO BE REMOVED BY UTILITY IN THE FUTURE METER FOR 1895 TO BE REMOVED BY UTILITY IN THE FUTURE UT I L I T Y CU S T O M E R (E) 800A SECTION (E) 800A SECTION 3 3 3 3 THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 2/ 1 4 / 2 0 2 5 1 2 : 5 0 : 3 6 P M Ut i l i t y C u s t o m e r N a m e : P r o l o g i s L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 1 9 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-9.2 Si n g l e L i n e D i a g r a m S y s t e m 2 SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 12" = 1'-0"1 Single Line Diagram System 2 * NOTE: ALL TERMINATIONS TO BE RATED TO 75°C OR MORE TERMINATION... Te r m T e m p R a t i n g Term Amp Rating >=Amps Max . . 60 30 >=17 60 30 >=23 60 30 >=23 75 150 >=121 75 255 >=241 75 255 >=241 VOLTAGE DROP CHART1 Vd r o p A m p s I m p Vd r o p V m p Vd r o p D i s t a n c e Vd r o p P e r c e n t . . 10.63 91.26 1 0.03 18 850 100 0.53 18 850 175 0.92 96.5 480 10 0.05 193 480 125 0.52 193 480 15 0.06 WIRE RATING CHART1 Pa r a l l e l R u n s Wi r e A m p R a t i n g Wi r e T e m p D e r a t e Wi r e C o n d u c t o r D e r a t e Derated Wire Rating <= Amps Max . . 1 40 0.96 1 1 X 40A X 0.96 X 1 = 38 >= 17 1 40 0.96 1 1 X 40A X 0.96 X 1 = 38 >= 23 1 40 0.96 0.8 1 X 40A X 0.96 X 0.8 = 31 >= 23 1 170 0.96 1 1 X 170A X 0.96 X 1 = 163 >= 121 1 290 0.96 1 1 X 290A X 0.96 X 1 = 278 >= 241 1 290 0.96 1 1 X 290A X 0.96 X 1 = 278 >= 241 WIRING CHART1 Ca l l o u t # Am p s I s c NE C M u l t Am p s M a x Pa r a l l e l R u n s Nu m b e r C o n d u c t o r s Si z e C o n d u c t o r Co n d u c t o r M a t l In s u l a t i o n C o n d u c t o r Si z e N e u t r a l Si z e G r o u n d Co n d u i t Q t y Wi r e T e m p R a t i n g Wi r e A m b T e m p Wi r e R o o f T e m p Wi r e T e m p T o t a l Co n d u c t o r s C u r r e n t C a r r y i n g . . 1 11.16 1.56 17 1 2 #10 AWG CU PV WIRE NA #6 AWG 1 90 31 0 31 2 2 18 1.25 23 1 2 #10 AWG CU PV WIRE NA #6 AWG 1 90 31 0 31 2 3 18 1.25 23 1 6 #10 AWG CU PV WIRE NA #6 AWG 1 90 31 0 31 6 4 96.5 1.25 121 1 3 #1/O AWG CU THWN-2 #6 AWG #6 AWG 1 90 31 0 31 3 5.1 193 1.25 241 1 3 #250 MCM CU THWN-2 #2 AWG #4 AWG 1 90 31 0 31 3 6 193 1.25 241 1 3 #250 MCM CU THWN-2 #250 MCM #2 AWG 1 90 31 0 31 3 THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF CONTRACTOR IS STRICTLY FORBIDDEN. DA T E : X_____________________________ SKYBRIDGE RENEWABLES LLC 127 MAYFAIR ALISO VIEJO, CA 92656 TEL: (949) 424-9320 2/ 1 4 / 2 0 2 5 1 2 : 5 0 : 3 6 P M Ut i l i t y C u s t o m e r N a m e : P r o l o g i s L o g i s t i c S e r v I n c - Sa n t a A n a D i s t r i b u t i o n C e n t e r 1 1 9 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 & 1 8 9 5 S S t a n d a r d A v e S a n t a A n a , C A 9 2 7 0 7 PV-9.2 Si n g l e L i n e D i a g r a m S y s t e m 2 SKYBRIDGE RENEWABLES LLC C10 - 1112028 10/31/2025 Ut i l i t y M e t e r C u s t o m e r A d d r e s s : 1 8 9 5 S S T A N D A R D , A V E S A N T A A N A , C A 9 2 7 0 7 Ut i l i t y C u s t o m e r N a m e : P r o l o g i s L o g i s t i c S e r v I n c . No . De sc ri pt ion Da t e 3 C o n st . Ch g # 1 2/ 1 4 / 2 5 No . De sc ri pt ion Da t e 3 C o n st . Ch g # 1 2/ 1 4 / 2 5 3 1895 & 1995 S Standard Ave5/5/2025