Loading...
HomeMy WebLinkAbout1851 E Deere Ave - PlanRE V DE S C R I P T I O N PR E P CH E C K D A T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1" 2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SETRACKING CONSTRUCTION SET GENERAL NOTES: 1. ALL SITE, PROJECT, AND BUILDING DETAILS ARE PROVIDED BY CUSTOMER OR GENERATED VIA SATELLITE IMAGERY FROM INFORMATION PROVIDED BY CUSTOMER. PANELCLAW IS NOT RESPONSIBLE FOR SITE INACCURACIES THAT COULD LEAD TO CHANGES TO THESE DRAWING DETAILS AND ARRAY LAYOUT CONFIGURATIONS. ALL INFORMATION CONTAINED WITHIN THESE DOCUMENTS ARE TO BE FIELD VERIFIED BY CUSTOMER AND INSTALLER. ANY CHANGES OR MODIFICATIONS TO THESE DOCUMENTS, CONTAINED INFORMATION, OR FINAL ARRAY AND MOUNTING SYSTEM INSTALLATIONS MUST BE SUBMITTED TO PANELCLAW AND OTHER PROJECT AUTHORITIES FOR APPROVAL. 2. REFER TO AND FOLLOW THE APPROPRIATE PANELCLAW INSTALLATION MANUALS AND PROCEDURES DURING THE INSTALLATION PROCESS. NOT FOLLOWING SUCH PROCEDURES AND METHODS COULD RESULT IN DAMAGE TO THE COMPONENTS OR MAY VOID THE PRODUCT WARRANTY. 3. ARRAY SETBACKS: ALL ARRAYS ARE REQUIRED TO BE SETBACK 4-FEET FROM ALL ROOF EDGES UNLESS OTHERWISE SPECIFIED AND CALLED OUT ON THE ARRAY DIAGRAMS ON THIS PAGE OR ON ADDITIONAL ARRAY BALLAST PAGES 4. REFER TO THE SPECIFIC ARRAY BALLAST SHEETS FOR BALLASTING REQUIREMENTS BASED ON THE PROVIDED SITE INFORMATION 5. SYSTEM PSF INCLUDES ALL PANELCLAW RACKING COMPONENTS, MECHANICAL ATTACHMENTS (IF APPLICABLE), PV MODULE AND BALLAST BLOCKS. FOR MAXIMUM SYSTEM POINT LOAD SUMMARY (PLS), REFER TO CALCULATIONS. 6. PANELCLAW AND/OR PANELCLAW CONSULTING ENGINEERS ARE NOT RESPONSIBLE FOR DETERMINING THE ADEQUACY OF THE STRUCTURE TO SUPPORT LOADS IMPOSED BY THE ARRAY AND MOUNTING SYSTEM. SUPPORT STRUCTURE TO BE CHECKED BY OTHERS 7. ALWAYS ALLOW 6” CLEARANCE BETWEEN NEIGHBORING SUBARRAYS, 6” BETWEEN SUBARRAYS AND ALL FIXED ROOF OBJECTS AND 4' BETWEEN SUBARRAYS AND ROOF EDGES. REFER TO LOCAL FIRE CODES AND ELECTRICAL CODES FOR ADDITIONAL REQUIREMENTS WHICH MAY GOVERN DESIGN. SUBARRAYS THAT USE A SEISMIC ANALYSIS METHOD OF DELTA MPV PER SEAOC OR ASCE 7-16 HAVE THEIR OWN CLEARANCE REQUIREMENTS. REFER TO THE BALLAST LAYOUT SHEETS WITHIN THIS DOCUMENT FOR DETAILS. 8. BALLAST BLOCK DIMENSIONS MUST CONFORM TO THE FOLLOWING SPECIFICATIONS: 3-3/4” THICK MAX., 7-5/8” ± 1/8” WIDTH, 15-5/8” ± 1/8” LENGTH. 9. IF AN ARRAY CLEARANCES TABLE APPEARS BELOW ON THIS PAGE, THE DESIGN UTILIZES THIRD PARTY SEISMIC NON-LINEAR RESPONSE ANALYSIS TO ESTIMATE MAXIMUM ARRAY SEISMIC DISPLACEMENT. THE PREDICTED MOVEMENT IS ONLY AN ESTIMATE. PANELCLAW IS NOT RESPONSIBLE OR LIABLE FOR ANY DAMAGES OR COSTS ASSOCIATED WITH PV ARRAY MOVEMENT INCLUDING MOVEMENT IN EXCESS OF THE CLEARANCES NOTED IN THIS DOCUMENT OR ANY REQUIREMENT TO REPOSITION THE ARRAYS IF MOVEMENT OCCURS. 10. DEFLECTORS MUST BE INSTALLED WHEN WINDS ARE EXPECTED TO EXCEED APPROX. 25% OF WIND SPEED DOCUMENTED IN SITE DESIGN CRITERIA TABLE. DEFLECTORS ARE REQUIRED ON ALL MODULES UNLESS OTHERWISE NOTED ON BALLAST LAYOUT PAGES. REQUIRED ARRAY CLEARANCES PER ASCE 7-16 CONDITION DESCRIPTION MINIMUM SEPARATION 1 BETWEEN SEPARATE SOLAR ARRAYS OF SIMILAR CONSTRUCTION (0.5) (Mpv) 2 BETWEEN A SOLAR ARRAY AND A FIXED OBJECT ON THE ROOF OR SOLAR ARRAY OF DIFFERENT CONSTRUCTION (Mpv) 3 BETWEEN A SOLAR ARRAY AND A ROOF EDGE WITH A QUALIFYING PARAPET (Mpv) 4 BETWEEN A SOLAR ARRAY AND A ROOF EDGE WITHOUT A QUALIFYING PARAPET (2.0) (Mpv) >= 4ft NOTE: SUFFICIENT SLACK IN ARRAY ELECTRICAL WIRING MUST BE PROVIDED TO ACCOMMODATE ALL POTENTIAL ARRAY MOVEMENT. SHEET INDEX NO.DESCRIPTION PC-1 COVER SHEET PC-2 PROJECT SUMMARY PC-3 ARRAY SITE MAP PC-4 TYPICAL ARRAY DIMENSIONS PC-5 ASSEMBLIES PC-6 RACKING COMPONENTS PC-7 BALLAST LEGEND PC-8 TO PC-12 BALLAST LAYOUT - 1 TO 5 PC-13 MECHANICAL ATTACHMENT DETAIL Site Design Criteria - Flat Roof PV System Basis of Design Roof Live Load (psf)20(see footnote 1) Ground Snow Pg (psf)0 Flat Roof Snow Pf (psf)0 Snow Importance Factor (Is)1.0 Wind Design Data Basic Wind Speed (mph)95 Risk Category II Wind Exposure C Earthquake Design Data Risk Category II Importance Factor (Ie)1.00 Component Importance Factor (Ip)1.0 Mapped Acceleration Parameter (Ss)1.266 Mapped Acceleration Parameter(S1)0.454 Seismic Site Class D Design Spectral Acceleration Parameter (Sds)1.013 Design Spectral Acceleration Parameter (Sd1)0.559 Seismic Design Category (SDC)D Basic seismic-force-resisting system(s)ASCE 7 sec. 13.6.12 & roof anchors Base Design Shear = Fp x W 0.49 W Response Modification Factor (R)2.5 Analysis Procedure ASCE 7 sec. 13.6.12 & ASCE 7 sec. 13.3/4 Design Code (with local amendments)2022 CBC -ASCE 7 - 16 ALTERNATE DESIGN METHOD SEAOC PV1 -SEAOC PV2 1. Roof Live Load only applicable to areas not covered by PV modules. Reference SEAOC Design Guidelines AERIAL PHOTO / SITE DIAGRAM THIS CONSTRUCTION SET PROVIDES THE RACKING LAYOUT FOR ALL ARRAYS WITH NUMBER OF BALLAST BLOCKS AND/OR MECHANICAL ATTACHMENTS BASED ON THE APPROVED STRUCTURAL CALCULATIONS FOR THE COMPLETED INSTALLED CONDITION OF THE SOLAR ARRAY. THE INSTALLER IS RESPONSIBLE FOR THE SAFETY AND CARE OF THE ARRAY DURING ALL PHASES OF INSTALLATION. THEREFORE, THE INSTALLER MUST MONITOR THE WEATHER FORECAST AND TAKE NECESSARY PRECAUTIONS (SEE GENERAL NOTE #10) TO TEMPORARILY SHORE/BRACE ALL ARRAYS DURING CONSTRUCTION UNTIL INSTALLATION IS COMPLETED IN CONFORMANCE WITH THIS APPROVED CONSTRUCTION SET AND THE PRODUCT INSTALLATION MANUAL (SEE GENERAL NOTE #2). THE INSTALLER HAS SOLE RESPONSIBILITY FOR THE MEANS, METHODS, AND TECHNIQUES OF CONSTRUCTION OF THE SOLAR ARRAY FOR COMPLIANCE WITH LAWS, REGULATIONS, AND CODES, AND FOR THE SAFETY OF CONSTRUCTION APPLICABLE TO THIS WORK. APPROVED FOR CONSTRUCTION SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA COVER SHEET PC-12 24.02.21.0 v3.0.940 5.4.2 CM 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 24-0242-2971.1 3/26/2024 TROY E.TURLEY The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg#: 101118504 Elec#: 20182282 Approvals: Plng: FArias Bldg: WLee Elec: MSmith 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-0 DATE: 02/23/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B COVER PAGE 1 2 BUILDING PHOTO VICINITY MAP SCALE: NTS PV-0 PV-0 SCALE: NTS PROJECT SITE SCOPE OF WORK: TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM LOCATED AT 1851 E DEERE AVE, SANTA ANA, CA 92705, USA. THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDES STORAGE BATTERIES. SYSTEM RATING 582.62 kWDC 562.50 kWAC SHEET INDEX PV-0 COVER PAGE PV-1 SITE PLAN PV-2 ROOF PLAN & MODULES PV-2A STRING LAYOUT & BOM PV-3+ATTACHMENT DETAILS PV-4 ELECTRICAL LINE DIAGRAM PV-4A ELECTRICAL CALCULATIONS PV-4B SPECIFICATIONS & NOTES PV-5 SIGNAGE PV-6+EQUIPMENT SPECIFICATIONS PV-10 CERTIFICATE PC-1 TO PC-13 REPORT GOVERNING CODES 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA ENERGY EFFICIENCY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA ADMINISTRATIVE CODE EQUIPMENT SUMMARY 1089 ADANI SOLAR ASB-M10-535 (535W) MODULES 9 SUNNY TRIPOWER CORE1 62-US [480V] INVERTERS AHJ NAME : SANTA ANA CITY PROJECT SITE GENERAL NOTES: · THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE MODIFICATIONS IN CONSTRUCTION DETAILS. · ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR INSTALLATION OF ANY EQUIPMENT AT SITE. · CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. · CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL COMPENSATION. · DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST. · THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND COMPLETION OF THE WORK WITH APPROVED MATERIALS. · NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE ARCHITECT. · CONTRACTOR SHALL OBTAIN BUILDING PERMIT. NO WORK TO START UNLESS BUILDING PERMIT IS PROPERLY DISPLAYED. · ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE WITH THE REQUIREMENTS OF THE CA BUILDING CODE, THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. · IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. · THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE LOCAL LAWS & REGULATIONS. · THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. · CONTRACTORS SHALL OBTAIN FIRE CERTIFICATE UPON COMPLETION OF WORK. WIRING AND CONDUIT NOTES: ·ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE APPLICATIONS ·ALL PV CABLES AND HOMERUN WIRES BE #10AWG *USE-2, PV WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED ·ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [REF. TO CEC 2022] FOR MULTIPLE CONDUCTORS ·ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE DERATED ACCORDING TO [CEC 2022] BLACK ONLY** ·EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES ·PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 600V PER CEC 2022 OR 1000V PER CEC 2022 ·WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS ·ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION ·VOLTAGE DROP LIMITED TO 3% FOR DC CIRCUITS AS WELL AS FOR AC CIRCUIT ·AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY ELECTRICAL NOTES: · THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE INSTALLED ONLY BY QUALIFIED PEOPLE. A QUALIFIED PERSON IS ONE WHO HAS SKILLS AND KNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OF THE ELECTRICAL EQUIPMENT AND INSTALLATIONS AND HAS RECEIVED SAFETY TRAINING TO RECOGNIZE AND AVOID THE HAZARDS INVOLVED. (CEC 2022) · LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. FOR A LINE SIDE TAP CONNECTION, UTILITY NEEDS TO BE NOTIFIED WELL IN ADVANCE TO COORDINATE BUILDING ELECTRICAL SHUT OFF. · NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC. SUBCONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONS AND THE COORDINATION REQUIREMENTS OF OTHER TRADES. · ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TO QUALIFIED PERSONNEL. · ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WATERTIGHT AND APPROVED FOR USE IN WET LOCATIONS. (CEC 2022). · WIRING METHODS FOR PV SYSTEM CONDUCTORS AREN'T PERMITTED WITHIN 10 IN. OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE LOCATED DIRECTLY BELOW THE ROOF SURFACE THAT'S COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT WIRING · BACK-FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. · ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARE LISTED AS UV RESISTANT. · CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS IN CEC 2022 · MEASURE THE LINE-TO-LINE AND LINE-TO-NEUTRAL VOLTAGE OF ALL SERVICE ENTRANCE CONDUCTORS PRIOR TO INSTALLING ANY SOLAR EQUIPMENT. 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 2.3 ROOF INFORMATION ROOF HEIGHT (FT)30.00 PARAPET HEIGHT (FT) 4.0 ROOF TILT (DEG) 1 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 276 MODULE POWER (W) 535 ARRAY OUTPUT (Kw) 147.66 ARRAY AZIMUTH 220 PART QUANTITIES ITEM QTY Base 648 Module Connector 552 Rail 800 Cam 552 Cam Claw 552 Deflector 276 Base Pad 0 Ballast Block 362 Mechanical Attachment 29 LOADING DETAILS SINGLE MODULE WT (LB) 61.7 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 33407 ARRAY AREA (SQ. FT)9502 ARRAY LOAD (PSF) 3.52 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) N/A CONDITION 2 (in.) N/A CONDITION 3 (in.) N/A CONDITION 4 (in.) N/A APPROVED FOR CONSTRUCTION SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA BALLAST LAYOUT - 2.3 PC-102 24.02.21.0 v3.0.9405.4.2 CM BALLAST LAYOUT - 2.3 PC-10 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 1/12" = 1'-0" 2 2 1 1 1 2 2 2 2 2 2 2 2 2 2 2 1 2 1 2 1 2 2 1 2 1 2 1 2 2 1 1 1 2 1 2 2 1 2 2 1 2 2 2 2 2 1 2 1 2 1 3 3 2 2 1 2 2 1 2 4 2 5 5 2 2 3 2 1 2 3 2 2 1 2 3 4 1 2 1 1 1 3 3 1 2 1 1 1 3 2 2 1 1 2 2 2 3 2 2 2 3 3 1 2 2 2 2 2 3 1 5 2 2 2 2 2 2 4 5 1 2 2 2 2 1 4 2 4 4 1 1 2 2 2 1 1 3 3 1 1 1 2 2 1 1 1 4 1 1 2 3 4 2 1 1 2 2 2 3 3 1 2 2 2 3 3 3 2 1 1 3 4 2 2 13 4 1 2 3 92.06' 149.87' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 96 SOUTH ASSEMBLY 96 MIDDLE ASSEMBLY 360 NORTH SOUTH ASSEMBLY 0 24-0242-2971.1 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 2.4 ROOF INFORMATION ROOF HEIGHT (FT)30.00 PARAPET HEIGHT (FT) 4.0 ROOF TILT (DEG) 1 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 184 MODULE POWER (W) 535 ARRAY OUTPUT (Kw) 98.44 ARRAY AZIMUTH 220 PART QUANTITIES ITEM QTY Base 434 Module Connector 368 Rail 573 Cam 368 Cam Claw 368 Deflector 184 Base Pad 0 Ballast Block 356 Mechanical Attachment 15 LOADING DETAILS SINGLE MODULE WT (LB) 61.7 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 26060 ARRAY AREA (SQ. FT)6334 ARRAY LOAD (PSF) 4.11 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) N/A CONDITION 2 (in.) N/A CONDITION 3 (in.) N/A CONDITION 4 (in.) N/A APPROVED FOR CONSTRUCTION SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA BALLAST LAYOUT - 2.4 PC-112 24.02.21.0 v3.0.9405.4.2 CM BALLAST LAYOUT - 2.4 PC-11 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 1/12" = 1'-0" 2 43 2 1 2 3 2 2 1 2 1 2 2 1 2 2 2 2 3 2 2 4 2 2 2 2 3 3 2 2 2 4 3 1 3 3 2 5 1 1 1 2 2 1 1 2 2 1 1 2 2 2 1 2 2 2 2 3 2 1 1 2 2 1 2 2 1 2 1 1 1 2 3 3 2 2 1 2 4 2 4 1 2 1 2 3 2 4 1 2 1 2 3 2 3 3 1 4 2 2 2 1 1 2 4 2 3 5 4 4 2 2 2 2 4 2 3 3 2 4 4 2 2 2 3 1 1 3 2 3 4 2 3 4 2 2 2 2 3 2 4 2 4 1 2 2 2 2 3 3 1 2 2 2 4 3 2 22 87.45' 142.38' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 66 SOUTH ASSEMBLY 66 MIDDLE ASSEMBLY 236 NORTH SOUTH ASSEMBLY 0 24-0242-2971.1 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 2.5 ROOF INFORMATION ROOF HEIGHT (FT)30.00 PARAPET HEIGHT (FT) 4.0 ROOF TILT (DEG) 1 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 270 MODULE POWER (W) 535 ARRAY OUTPUT (Kw) 144.45 ARRAY AZIMUTH 220 PART QUANTITIES ITEM QTY Base 610 Module Connector 540 Rail 751 Cam 540 Cam Claw 540 Deflector 270 Base Pad 0 Ballast Block 343 Mechanical Attachment 24 LOADING DETAILS SINGLE MODULE WT (LB) 61.7 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 32196 ARRAY AREA (SQ. FT)9303 ARRAY LOAD (PSF) 3.46 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) N/A CONDITION 2 (in.) N/A CONDITION 3 (in.) N/A CONDITION 4 (in.) N/A APPROVED FOR CONSTRUCTION SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA BALLAST LAYOUT - 2.5 PC-122 24.02.21.0 v3.0.9405.4.2 CM BALLAST LAYOUT - 2.5 PC-12 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 1/12" = 1'-0" 43 4 4 2 4 3 2 2 4 2 2 3 4 2 2 1 2 22 23 2 3 3 3 1 4 1 5 4 3 3 2 4 4 3 2 1 2 5 3 3 2 1 1 2 1 3 2 2 1 2 1 3 2 1 2 1 3 2 2 2 2 1 4 1 2 2 2 2 1 2 3 2 1 1 2 1 2 1 1 2 1 1 1 1 4 1 1 1 1 3 2 1 1 11 1 3 1 1 2 2 1 2 2 2 2 2 1 3 2 2 3 2 1 1 3 2 2 1 1 3 2 2 1 1 1 2 2 2 1 2 2 1 2 2 1 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 2 2 2 2 2 21 2 11 2 1 2 1 3 2 12 92.06' 149.87' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 70 SOUTH ASSEMBLY 70 MIDDLE ASSEMBLY 400 NORTH SOUTH ASSEMBLY 0 24-0242-2971.1 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: SITE MAP A PC-2NTS RACKING CONSTRUCTION SET SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA PROJECT SUMMARY PC-22 24.02.21.0 v3.0.9405.4.2 CM clawFR 10 Degree - 29 cm PROJECT PART QUANTITY ITEM PART NUMBER QTY Base 500050202 2520 BASE, 02, CFR Module Connector 500050704 2178 MODULE CONNECTOR, 1150, 10D, CFR Rail 2000895 3174 RAIL, 2500, CFR Cam 5000500 2178 CAM, 10D, CFR Cam Claw 2000673 2178 CAM CLAW, CFR Deflector 200088705 1089 DEFLECTOR, 10D, 2300, CFR Bolt 2000697 11296 BLT, HEX FLG, TRI, M6X16, GR8.8, PATCH Base Pad 2000678 0 PAD, BASE, CFR CONCRETE MASONRY UNIT N/A 1605 BLOCK, CONCRETE, 32.6 LB, - Xin x 8in x 16in NOMINAL, PARTNER SUPPLIED, SEE INSTALLATION MANUAL APPROVED FOR CONSTRUCTION MECHANICAL ATTACHMENT PART QUANTITY MA Hardware Kit 5000423 9 HW KIT, MA STRUT, 2500, CFR MA Strut 2000930 87 MA STRUT, 2500, CFR Mechanical Attachment 100035906 87 MA, ANCH 2400, SIKA PVC TOTAL MECHANICAL ATTACHMENT COUNT 87 PROJECT SUMMARY MODULE TYPE ADANI ASB-M10-144-535 MODULE DIMENSIONS (IN.)89.21 X 44.61 X 1.38 NUMBER OF MODULES 1089 MODULE WATTAGE (W STC)535 SYSTEM SIZE (kW STC)582.615 SYSTEM WEIGHT (LB)137360 SYSTEM AREA (SQ FT.)37504 AGGREGATE SYSTEM LOAD (PSF)3.66 NUMBER OF ARRAYS 5 ARRAY TILT (DEG)8.99 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 Roof 1 Roof 2 24-0242-2971.1 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: # RACKING CONSTRUCTION SET NOTES: 1.ALL DIMENSIONS SHOWN ARE BASED UPON INFORMATION PROVIDED TO PANELCLAW. FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION OF THE SOLAR ARRAY. NOTIFY PANELCLAW OF ANY DISCREPANCIES. APPROVED FOR CONSTRUCTION SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA ARRAY SITE MAP PC-32 24.02.21.0 v3.0.9405.4.2 CM ROOF NAME ROOF SETBACK (FT.) ROOF HEIGHT (FT) PARAPET HEIGHT (FT) ROOF TILT (DEG) Roof 1 4.00 20.00 5.0 1 Roof 2 4.00 30.00 4.0 1 KEEPOUT NAME KEEPOUT CLEARANCE (FT.) KEEPOUT HEIGHT (IN.) Group 1 4 192 Group 2 4 168 Group 2 4 48 Group 3 4 36 Group 3 4 12 Group 4 4 72 3 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 209' 14' 67' 123' 199' 322' 157' 79' 108' 43'8'56' 202' 233' 1 243' 42' 79' 157' 322' 199' 2 3 4 5 24-0242-2971.1 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 A (REPEAT DIMENSION EAST-WEST) PL (PANEL LENGTH) M (PROJECTED PANEL WIDTH) B (REPEAT DIMENSION NORTH-SOUTH) C J PT P D PW D ° O W K X 19 mm (0.748 in) 'L' RAIL INSTALLATION: USE THE OUTER SET OF HOLES WHEN INSTALLING RAILS BETWEEN MODULES. N G 32 . 9 m m ( 1 . 2 9 5 i n ) S (ON-MODULE BASE SPACING) L (BETWEEN-MODULE BASE SPACING)R AEBE RAIL ON “L” SPACING IS ALWAYS ON TOP OF RAIL ON “S” SPACING. THIS INSTALLATION SEQUENCE IS CRITICAL TO SYSTEM PERFORMANCE. FOR MORE INFORMATION REVIEW THE INSTALLATION MANUAL AND VIDEOS. RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: ARRAY TOP VIEW B NTSSCALE: ARRAY CROSS SECTION VIEW A NTS SCALE: RAIL DETAIL C NTS RACKING CONSTRUCTION SET SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA 2 24.02.21.0 v3.0.9405.4.2 CM INSTALLED ARRAY DIMENSIONS A B C D G J K M N O P R W X Theta (DEG)D/J (#:1)G.C.R.* mm 2285 1404 123 285 116 177 211 1119 82 61 87 516 270 136 8.99 1.61 0.81UNITS inches 89.96 55.29 4.84 11.23 4.58 6.97 8.30 44.06 3.21 2.39 3.42 20 5/16 10.62 5.35 8.99 1.61 0.81 * G.C.R = (PW) / B INSTALLATION MEASUREMENTS AEBE S L CAM SPACING* mm 486 1235 1050 59UNITS inches 19 1/8 48 5/8 41 5/16 2 5/16 *CAM SPACING SHOWN ON ASSEMBLIES PAGE. MODULE DIMENSIONS PL PW PT mm 2266 1133 35UNITS inches 89.21 44.61 1.38 PC-4 PC-4 PC-4 TYPICAL ARRAY DIMENSIONS PC-4 APPROVED FOR CONSTRUCTION 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 24-0242-2971.1 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.1 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 5.0 ROOF TILT (DEG) 1 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 104 MODULE POWER (W) 535 ARRAY OUTPUT (Kw) 55.64 ARRAY AZIMUTH 220 PART QUANTITIES ITEM QTY Base 258 Module Connector 208 Rail 314 Cam 208 Cam Claw 208 Deflector 104 Base Pad 0 Ballast Block 110 LOADING DETAILS SINGLE MODULE WT (LB) 61.7 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 11681 ARRAY AREA (SQ. FT)3576 ARRAY LOAD (PSF) 3.27 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 3 CONDITION 2 (in.) 6 CONDITION 3 (in.) 6 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA BALLAST LAYOUT - 1.1 PC-82 24.02.21.0 v3.0.9405.4.2 CM BALLAST LAYOUT - 1.1 PC-8 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 1/6" = 1'-0" 12 12 12 2 12 2 2 1 2 1 2 2 2 2 2 22 2 2222 2 2 1 2 1 1 2 2 1 1 2 1 11 1 1 2 2 2 1 2 2 2 1 2 2 2 2 1 2 1 3 2 2 1 2 22 2 55.20' 104.89' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 44 SOUTH ASSEMBLY 44 MIDDLE ASSEMBLY 114 NORTH SOUTH ASSEMBLY 6 24-0242-2971.1 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 2.2 ROOF INFORMATION ROOF HEIGHT (FT)30.00 PARAPET HEIGHT (FT) 4.0 ROOF TILT (DEG) 1 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 255 MODULE POWER (W) 535 ARRAY OUTPUT (Kw) 136.425 ARRAY AZIMUTH 220 PART QUANTITIES ITEM QTY Base 570 Module Connector 510 Rail 736 Cam 510 Cam Claw 510 Deflector 255 Base Pad 0 Ballast Block 434 Mechanical Attachment 19 LOADING DETAILS SINGLE MODULE WT (LB) 61.7 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 34016 ARRAY AREA (SQ. FT)8788 ARRAY LOAD (PSF) 3.87 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) N/A CONDITION 2 (in.) N/A CONDITION 3 (in.) N/A CONDITION 4 (in.) N/A APPROVED FOR CONSTRUCTION SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA BALLAST LAYOUT - 2.2 PC-92 24.02.21.0 v3.0.9405.4.2 CM BALLAST LAYOUT - 2.2 PC-9 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 1/12" = 1'-0" 41 4 2 4 2 4 2 1 4 2 4 1 1 5 1 2 1 2 1 1 1 1 3 3 3 1 2 3 3 1 1 2 3 1 1 2 2 1 1 1 1 1 1 2 5 2 1 2 2 3 3 1 2 1 1 2 1 1 4 2 2 12 1 2 1 2 2 1 1 2 2 2 2 1 2 2 2 2 2 2 2 2 2 21 2 1 1 1 2 1 2 1 2 1 3 1 1 2 3 3 3 1 1 1 4 3 1 1 3 1 3 1 2 1 3 2 3 2 3 3 3 3 3 2 3 3 2 1 3 2 3 2 3 14 1 3 1 5 1 2 3 1 5 3 2 2 4 3 3 4 31 2 2 2 2 1 2 2 2 2 1 1 1 2 1 1 3 2 1 1 2 1 2 3 1 2 1 3 1 2 1 1 3 2 2 1 1 5 3 2 1 1 5 2 1 4 3 23 43 44 5 92.06' 149.87' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 58 SOUTH ASSEMBLY 58 MIDDLE ASSEMBLY 392 NORTH SOUTH ASSEMBLY 2 24-0242-2971.1 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 539 ' - 6 " 46'-7" 184 ' - 0 " 628 ' - 6 " 368'-6 " SLC MDP UM ACD 39'-10" 283 ' - 5 " 301 ' - 4 " 426 ' - 4 " 98' - 9 " INV INV INV INV INV INV INV INV INV PVM GEN MSB T T T T MDP UM SLC INV INV INV INV INV INV INV INV INV ACD PVM T MS B T T T GEN SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-1 DATE: 02/23/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B PLOT PLAN WITH ROOF PLAN PV-1 1 SCALE: 3/128"=1'-0" SITE PLAN ROOF #1 (985) ADANI SOLAR ASB-M10-535 (535W) MODULES (E) DRIVEWAY TREES (E) UTILITY METER PROP E R T Y L I N E PRO P E R T Y L I N E PRO P E R T Y L I N E PR O P E R T Y L I N E ROOF #2 (104) ADANI SOLAR ASB-M10-535 (535W) MODULES (E) FENCE ELECTRICAL ROOM (E) MAIN DISTRIBUTION PANEL (N) AC DISCONNECT (E) SOLAR LOAD CENTER (ON ROOF) (N) RACK (TYP.) SITE NOTES · A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. · THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM . · THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. · PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [CEC 2022] ELECTRICAL ROOM 2 (N) 3 x SUNNY TRIPOWER CORE1 62-US [480V] INVERTERS (N) 6 x SUNNY TRIPOWER CORE1 62-US [480V] INVERTERS (N) PV PRODUCTION METER (E) TRANSFORMER (E) TRANSFORMER (E) MAIN SWITCHBOARD (E) GENERATER PULLM A N S T E D E E R E A V E 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 48" FIRE SETBACK 48" FIRE SETBACK 48 " F I R E S E T B A C K 48 " F I R E S E T B A C K 52 ' - 5 " 40 ' - 3 " 90 ' - 7 " 7' - 2 " SLCMDPUMACD 72" FIRE SETBACK 72" FIRE SETBACK 72" FIRE SETBACK 72 " F I R E S E T B A C K 72 " F I R E S E T B A C K 5' - 6 " 48" FIRE SETBACK 48" FIRE SETBACK48" FIRE SETBACK 48 " F I R E S E T B A C K 72 " F I R E S E T B A C K 48 " F I R E S E T B A C K INV INV INV INVINV INV INV INV INV JB 7'-5"59'-7"22'-5"11'-5" JB JB JB JB JB JB JB JB JB JB JB JB JB JB JB JB JB 36" FIRE SETBACK 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K PVM 15 ' - 5 " 40 ' - 3 " 13 ' - 9 " 9' - 4 " 21'-5"74'-6"14'-11" 14'-11" 11'-4" GEN MS B T T T T 7'-5" 74'-6" 8' - 1 1 " 31 ' - 1 " 23 ' - 4 " 40 ' - 3 " 14 ' - 8 " 35 ' - 8 " 7' - 7 " 89'-6"6'-11"149'-1" MDP UM ACD PVM SLC SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-2 DATE: 02/23/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B 1 ROOF PLAN & MODULES PV-2 SCALE: 1/32" = 1'-0" ADANI SOLAR ASB-M10-535 (535W) MODULES 89 . 2 1 " 44.61" DESIGN SPECIFICATION RISK CATEGORY:II CONSTRUCTION:COMMERCIAL ZONING:COMMERCIAL SNOW LOAD (ASCE 7-16):0 PSF EXPOSURE CATEGORY:C WIND SPEED (ASCE 7-16):95 MPH MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES:1089 MODULES MODULE TYPE:ADANI SOLAR ASB-M10-535 (535W) MODULES MODULE WEIGHT:61.73 LBS MODULE DIMENSIONS:89.21" X 44.61" = 27.64 SF UNIT WEIGHT OF AREA:2.23 PSF ROOF PLAN & MODULES - JUNCTION BOXJB ROOF DESCRIPTION ROOF ROOF TILT AZIMUTH ROOF MATERIAL #1 0°220°PVC/TPO #2 0°220°PVC/TPO ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 985 27215.55 60885.52 45 #2 104 2873.52 9778.34 29 LEGEND MDP - VENT, ATTIC FAN (ROOF OBSTRUCTION) - MAIN DISTRIBUTION PANEL UM - UTILITY METER ACD - AC DISCONNECT 72" FIRE SETBACK (N) BALLAST BLOCK (N) RAIL ROOFS #1 & #2 (1089) ADANI SOLAR ASB-M10-535 (535W) MODULES (E ) FR O N T O F B U I L D I N G PU L L M A N S T (E ) BA C K O F B U I L D I N G - BALLAST BLOCK - RAIL (N) 9 x SUNNY TRIPOWER CORE1 62-US [480V] INVERTERS (ON ROOF) - SUNNY TRIPOWER CORE1 62-US [480V] (N) PANELCLAW CLAW FR 10 DEGREE RACKING SYSTEM (N) EMT CONDUIT 48" FIRE SETBACK SLC - SOLAR LOAD CENTER (E) UTILITY METER (E) MAIN DISTRIBUTION PANEL (N) AC DISCONNECT (E) SOLAR LOAD CENTER (ON ROOF) (N) RACK (TYP.) (N) JUNCTION BOX (TYP.) ARRAYS #1 TO #5 ARRAY TILT - 10° AZIM. - 220° 36" FIRE SETBACK ELECTRICAL ROOM ELECTRICAL ROOM 2 INV (N) PV PRODUCTION METER (E) TRANSFORMER (E) GENERATOR (E) 3 x TRANSFORMERS (E) MAIN SWITCHBOARD - TRANSFROMERT - GENERATORGEN MSB - MAIN SWITCHBOARD PVM - PV PRODUCTION METER - MECHANICAL ATTACHMENT (N) MECHANICAL ATTACHMENT E DEERE AVE 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 U-ANCHOR 2400 MECHANICAL ATTACHMENT: MANUFACTURED BY OTHERS NOTE: THIS DETAIL IS GENERIC IN NATURE AND IS INTENDED ONLY TO SHOW TYPICAL MECHANICAL ATTACHMENT ASSEMBLY LOCATIONS. REFER TO INDIVIDUAL ARRAY LAYOUTS FOR REQUIRED LOCATIONS. U-ANCHOR 2400 MECHANICAL ATTACHMENT ø 6.4 mm (0.25 in) MECHANICAL ATTACHMENT WORST-CASE SERVICE LOAD (LB) HORIZONTAL (H)VERTICAL (V) WIND SEISMIC WIND MAXIMUM ALLOWABLE LOAD (LB) HORIZONTAL (H)VERTICAL (V) RACKING CONSTRUCTION SET SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA 2 PC-13 MECHANICAL ATTACHMENT DETAIL 24.02.21.0 v3.0.9405.4.2 CM 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 0 610 469 650 525 APPROVED FOR CONSTRUCTION PC-13 PC-13 PC-13 24-0242-2971.1 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 CAM SPACING BASE HOLE "2" BASE HOLE "1" BASE HOLE "1" BASE HOLE "2" BASE HOLE "3" BASE HOLE "3" BASE HOLE "1"BASE HOLE "3"BASE HOLE "1"BASE HOLE "3"BASE HOLE "3"BASE HOLE "1"BASE HOLE "3"BASE HOLE "2" ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: CAM SPACING DETAIL A NTS SCALE: NORTH ASSEMBLY B NTS SCALE: SOUTH ASSEMBLY D NTS SCALE: MIDDLE ASSEMBLY C NTS SCALE: NORTH SOUTH ASSEMBLY E NTS SCALE: EXAMPLE ARRAY CONSTRUCTION F NTS RACKING CONSTRUCTION SET SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA ASSEMBLIES PC-52 24.02.21.0 v3.0.9405.4.2 CM APPROVED FOR CONSTRUCTION PC-5 PC-5 PC-5 PC-5 PC-5 PC-5 STANDARD ASSEMBLY QUANTITY NORTH ASSEMBLY 334 SOUTH ASSEMBLY 334 MIDDLE ASSEMBLY 1502 NORTH SOUTH ASSEMBLY 8 NOTE: ASSEMBLIES IN THIS TABLE USE THE STANDARD 2-PAD BASE CAM SPACING mm 59UNITS inches 2 5/16 24-0242-2971.1 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 NOTE: EXAMPLE BALLASTING SHOWN ON THIS PAGE IS FOR REFERENCE ONLY AND DO NOT REFLECT TYPICAL BALLAST PLACEMENT. REFER TO BALLAST MAP SHEETS FOR ARRAY SPECIFIC BALLAST REQUIREMENTS. BASE RAIL DEFLECTOR CAM BRACKET AND CAM CLAW TRANSPARENT MODULE MODULE CONNECTOR RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: CAM BRACKET C NTS SCALE: CAM CLAW B NTS SCALE: RAIL F NTS SCALE: BASE D NTS SCALE: MODULE CONNECTOR E NTSSCALE: DEFLECTOR G NTS SCALE: EXAMPLE RAIL AND BLOCK CONFIGURATION A NTS RACKING CONSTRUCTION SET SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA 2 APPROVED FOR CONSTRUCTION PC-6 RACKING COMPONENTS 24.02.21.0 v3.0.9405.4.2 CM PC-6 PC-6 PC-6 PC-6 PC-6 PC-6PC-6 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 24-0242-2971.1 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 MECHANICAL ATTACHMENT AT INDICATED LOCATION NOTE: EXAMPLE BALLAST AND ATTACHMENTS SHOWN ON THIS PAGE ARE FOR REFERENCE ONLY. REFER TO BALLAST MAP SHEETS FOR ARRAY SPECIFIC BALLAST/ATTACHMENT REQUIREMENTS. BALLAST QUANTITY: "#"=QUANTITY OF BALLAST BLOCK INSTALLEDCENTERED UNDER MODULE IF NO BALLAST QUANTITY SHOWN, DO NOT PLACE BALLAST SEE INSTALLATION MANUAL FOR NOTES ON INSTALLING MORE THAN FOUR BALLAST BLOCKS PER MODULE DO NOT INSTALL ADDITIONAL RAIL TO HOLDBALLAST ON MODULES WITH NO BALLASTSHOWN. A NTS RACKING CONSTRUCTION SET SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA 2 PC-7 BALLAST LEGEND APPROVED FOR CONSTRUCTION 24.02.21.0 v3.0.9405.4.2 CM PC-7 PC-7 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 24-0242-2971.1 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-3 DATE: 02/23/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B ATTACHMENT DETAILS PV MODULES BALLAST BLOCKBASECAM CLAM CAM SEAT TILT ARM LOCK CLAW 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-3A DATE: 02/23/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B ATTACHMENT DETAILS 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 SLCMDPUMACD INV INV INV INVINV INV INV INV INV JB 1 17 1 18 1 18 1 1717 1 1 17 1 17 1 17 18 18 1 1 1 17 1 17 1 1 1 17 17 17 171 JB JB JB 1 1 1 17 1717 1 161 17 1 17 JB 11 17 17 JB 16 1 1 17 1 17 17 1 1 17 117 1 17 1 17 JB JB 1 16 16 1 1 16 1 16 JB 1 116 16 1 16 1 16 JB 16 1 1 15 16 1 1 16 JB 16 1 1 16 1 16 1 16 JB 16 1 1 16 1 15 1 15 1 15 JB 1 15 1 16 1 15 1 16 JB JB 1 15 1 15 1 15 JB 1 1 1 18 18 17 1 17 JB 1 17 1 17 JB PVM GEN MS B T T T T SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-2A DATE: 02/23/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B 1 STRING LAYOUT & BOM PV-2A SCALE: 1/32" = 1'-0" STRING LAYOUT & BOM BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 1089 ADANI SOLAR ASB-M10-535 (535W) MODULES INVERTER 9 SUNNY TRIPOWER CORE1 62-US [480V] INVERTERS JUNCTION BOX 18 JUNCTION BOX, NEMA 3R, UL LISTED SOLAR LOAD CENTER 1 SOLAR LOAD CENTER 1000A RATED, 480V, 3PH, 4W MONITORING SYSTEM 1 ALSO ENERGY DATA AGGREGATION SYSTEM PRODUCTION METER 1 PV PRODUCTION METER AC DISCONNECT 1 1000A FUSED AC DISCONNECT WITH (3) 1000A FUSES, 480V, 3PH, 4W, NEMA 3R UL LISTED PU L L M A N S T (E ) F R O N T O F B U I L D I N G (E ) B A C K O F B U I L D I N G INVERTER #1 02 x STRINGS OF 18 MODULES 06 x STRINGS OF 17 MODULES = 138 MODULES STRING INFORMATION INVERTER #2 02 x STRINGS OF 18 MODULES 06 x STRINGS OF 17 MODULES = 138 MODULES INVERTER #3 01 x STRING OF 16 MODULES 07 x STRINGS OF 17 MODULES = 135 MODULES INVERTER #4 01 x STRING OF 16 MODULES 07 x STRINGS OF 17 MODULES = 135 MODULES INVERTER #5 08 x STRINGS OF 16 MODULES = 128 MODULES INVERTER #6 01 x STRING OF 15 MODULES 07 x STRINGS OF 16 MODULES = 127 MODULES INVERTER #7 02 x STRINGS OF 16 MODULES 04 x STRINGS OF 15 MODULES = 92 MODULES INVERTER #8 02 x STRINGS OF 16 MODULES 04 x STRINGS OF 15 MODULES = 92 MODULES INVERTER #9 02 x STRINGS OF 18 MODULES 04 x STRINGS OF 17 MODULES = 104 MODULES E DEERE AVE 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 21 3 21 3 5213 JUNCTION BOX-9, NEMA 3R, UL LISTED 15 16 21 3 (128) ADANI SOLAR ASB-M10-535 (535W) MODULES 8 x STRINGS OF 16 MODULES INVERTER #5 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 17 21 3 21 3 6213 JUNCTION BOX-10, NEMA 3R, UL LISTED 21 3 18 15 16 15 16 15 16 15 16 15 16 15 16 15 16 100A/3P 20A/3P (N) SOLAR LOAD CENTER, 1000A, 480V, 3-PH, 4-W 100A/3P 100A/3P 100A/3P 100A/3P 100A/3P 100A/3P 100A/3P 100A/3P 21 3 21 3 1213 JUNCTION BOX-1, NEMA 3R, UL LISTED 17 18 21 3 17 18 16 17 16 17 (138) ADANI SOLAR ASB-M10-535 (535W) MODULES 2 x STRINGS OF 18 MODULES 6 x STRINGS OF 17 MODULES INVERTER #1 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 13 21 3 21 3 2213 JUNCTION BOX-2, NEMA 3R, UL LISTED 21 3 16 17 16 17 16 17 16 17 14 { INVERTER #2 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 21 3 21 3 3213 JUNCTION BOX-5, NEMA 3R, UL LISTED 15 16 21 3 16 17 16 17 (135) ADANI SOLAR ASB-M10-535 (535W) MODULES 1 x STRING OF 16 MODULES 7 x STRINGS OF 17 MODULES INVERTER #3 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 15 21 3 21 3 4213 JUNCTION BOX-6, NEMA 3R, UL LISTED 21 3 16 17 16 17 16 17 16 17 16 17 16 { INVERTER #4 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 2 13 2 13 7 2 13 JUNCTION BOX-11, NEMA 3R, UL LISTED 1415 2 13 INVERTER #6 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 19 2 13 2 13 8 2 13 JUNCTION BOX-12, NEMA 3R, UL LISTED 2 13 20 1516 1516 1516 1516 1516 1516 1516 (127) ADANI SOLAR ASB-M10-535 (535W) MODULES 1 x STRING OF 15 MODULES 7 x STRINGS OF 16 MODULES 2 13 2 13 9 2 13 JUNCTION BOX-13, NEMA 3R, UL LISTED 1516 1516 1415 2 13 2 13 10 2 13 JUNCTION BOX-14, NEMA 3R, UL LISTED 1415 1415 1415 INVERTER #9 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 2 13 2 13 11 2 13 JUNCTION BOX-17, NEMA 3R, UL LISTED 1718 1617 2 13 2 13 12 2 13 JUNCTION BOX-18, NEMA 3R, UL LISTED INVERTER #7 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 1718 1617 1617 1617 } INVERTER #8 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT (104) ADANI SOLAR ASB-M10-535 (535W) MODULES 2 x STRINGS OF 18 MODULES 4 x STRINGS OF 17 MODULES (92) ADANI SOLAR ASB-M10-535 (535W) MODULES 2 x STRINGS OF 16 MODULES 4 x STRINGS OF 15 MODULES (N) ALSO ENERGY MONITORING SYSTEM VREF/PWR CT I/O (N) SERVICE DISCONNECT FOR PV SYSTEM: 480V, 1000A FUSED, NEMA 3R, UL LISTED (3 ) 1 0 0 0 A F U S E S CONTINUE TO SHEET NO. PV-4A 26 28 21 22 23 24 25 25 25 25 25 25 INVERTER #2 HAVE SAME MODULE COUNT AS INVERTER #1, INVERTER #4 HAVE SAME MODULE COUNT AS INVERTER #3, INVERTER #8 HAVE SAME MODULE COUNT AS INVERTER #7 }{ LINE LOAD (N) PV PRODUCTION METER 27 N-G BOND GROUND ELECTRODE CONDUCTOR NOTE: THE AC DISCONNECT IS SUITABLE FOR THE USE AS SERVICE EQUIPMENT (SUSE) CEC 230.82(6). MINIMUM 3/0 AWG SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-4 DATE: 03/27/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B REVISION 03/27/2024 C ELECTRICAL LINE DIAGRAM PV-4 ELECTRICAL LINE DIAGRAM SCALE: NTS 1 NORTH 1600A MAIN CIRCUIT BREAKER RATING: SERVICE INFO MAIN SERVICE VOLTAGE: MAIN SERVICE PANEL: MAIN SERVICE LOCATION: 480V 1600A NOTE: TAG NO 26, 27 & 28 HAVE FOUR PARALLEL SET OF 2.5" DIA CONDUIT AND EACH CONDUIT HAVE 4 CABLES (L1, L2, L3 & N) NOTE: INVERTERS #1, #2, #3, #4, #5, #6, #7, #8 & #9 HAVE SAME WIRE CALCULATIONS. 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 1 20A 3P HP-1 600A BUS 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 2 15A 3P HP-3 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 3 HP-4 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 4 HP-5 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 5 HP-6 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 6 HP-7 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 7 20A 3P HP-8 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 8 HP-9 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 9 HP-10 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 10 HP-11 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 11 HP-12 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 12 HP-13 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 13 HP-14 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 14 HP-15 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 15 HP-16 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 16 30A 3P HP-17 3/ 4 " C - 3 # 8 & 1 # 1 0 G N D 17 HP-18 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 18 HP-19 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 19 HP-20 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 20 20A 3P HP-21 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 21 HP-22 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 22 HP-23 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 23 HP-24 3/ 4 " C - 3 # 8 & 1 # 1 0 G N D 24 20A 3P HP-25 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 25 25A 3P HP-26 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 26 45A 3P HP-27 3/ 4 " C - 3 # 6 & 1 # 1 0 G N D 27 30A 3P HP-28 3/ 4 " C - 3 # 8 & 1 # 1 0 G N D 28 15A 3P EF-5 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 29 EF-6 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 30 EF-7 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 31 EF-8 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 32 EF-12 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 33 30A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 30A 3P 15A 3P 15A 3P 15A 3P 15A 3P 3 HMC1-1 480V, 3PH, 3W 11 1" C - 1 #3/0 G 11 1" C - 1 #3/0 G G 20 CLD1-1 200A 3P 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D 7 CLP1-1 500A 3P 600A BUS 208/120V, 3PH, 4W 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D 7 CLP1-2 200A 3P 200A 3P 200A 3P SPARE SPARE (2)3" C - (8)#250KCMIL & (2)#2 GND 1"C - 1#1/0G1- 1 / 4 " C - ( 4 ) # 6 A W G & 1 # 1 0 G N D 19 EHP1-1 CLP1-1, 32-34 14 50A 3P 225A 3P 225A 3P 50A 3P 400A 3P 175A 3P 225A 3P 500A 3P1600A 3PG 480/277V, 3PH, 3W PULL SECTION MAIN AND METER SECTION DISTRIBUTION SECTION 1-1/4" C - (4)#6 AWG & 1 #10 GND 1600A BUS MAX AVAILABLE FAULT CURRENT: 32KA SHORT CIRCUIT WITHSTAND RATING: 42KA (2)2-1/2" C - (6)#250KCMIL & 2 #1 GND (2)4" C.O.(2)5" C.O. 2" C - (3)#4/0 & 1 #2 GND "ATS-2" 260A/3P 480V 3PH, 3W 17 15 15 1 MSB-1-1 2" C - ( 3 ) # 4 / 0 & 1 # 2 G N D 1- 1 / 4 " C - ( 4 ) # 6 A W G & 1 # 1 0 G N D SOUTHERN CALIFORNIA EDISON TRANSFORMER AND FUSE SWITCH TO SOUTHERN CALIFORNIA EDISON POLE "ATS-1" 260A/4P 480/277V 3PH, 4W 16 EGRESS LTG PULLMAN CRITICAL LOADS 2" C - ( 3 ) # 4 / 0 & 1 # 2 G N D 19 HP1-1 LTGLCP1LCP2 2- 1 / 2 " C - ( 4 ) # 4 / 0 & 1 # 2 G N D "T1D" 150KVA 480-208/120V 3PH, 4W 18 3/4"C - 1#6G "T1B" 45KVA 208/120V 3PH, 4W 5 1- 1 / 4 " C - ( 3 ) # 4 A W G & 1 # 8 G N D 2" C - ( 4 ) # 1 / 0 A W G & 1 # 2 G N D LP1-5LP1-6 150A 3P MCB 8 (1)1-1/4"C W/ (4)#2AWG & 1 #8 GND 1"C - 1#1/0G "T1A" 112.5KVA 480-208/120V 3PH, 4W 4 2" C - ( 3 ) # 2 / 0 A W G & ( 1 ) # 6 G N D 3- 1 / 2 " C - ( 4 ) 5 0 0 K C M I L & ( 1 ) # 2 G N D 200A 3P 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D 7 LP1-1 400A BUS 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D 7 LP1-2 200A 3P PULLMAN HOUSE/OFFICE LOADS 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D 7 LP1-3 200A 3P 200A 3P SPARE 400A 3P 208/120V, 3PH, 4W (4) 225A BUSSES SPACE 2 LD1-1 12 LD1-2 200A 3P 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D 9 LP1-8 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D LP1-9 200A 3P PULLMAN LAB LOADS 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D LP1-10 200A 3P 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D LP1-11 200A 3P 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D LP1-12 200A 3P 9 9 9 9 200A 3P 200A 3P SPARE SPARE 225A 3P SPARE 800A BUS (4) 225A BUSSES SPACE 208/120V, 3PH, 4W 1"C - 1#3/0G "T1A" 225KVA 480-208/120V 3PH, 4W 10 (2 ) 2 " C - ( 6 ) # 3 / 0 A W G & ( 2 ) # 2 G N D (3 ) 4 " C - ( 1 2 ) 3 5 0 K C M I L & ( 3 ) # 1 / 0 G N D 800A 3P LINK BUILDING LOADS "GENERATOR" 150KW/187.5KVA 480/277V 3PH, 3W 13 M POINT OF INTERCONNECTION SUPPLY SIDE TAP CONTINUED FROM SHEET NO. PV-4 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-4A DATE: 03/27/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B REVISION 03/27/2024 C ELECTRICAL LINE DIAGRAM PV-4A ELECTRICAL LINE DIAGRAM SCALE: NTS 1 NORTH 1600A MAIN CIRCUIT BREAKER RATING: SERVICE INFO MAIN SERVICE VOLTAGE: MAIN SERVICE PANEL: MAIN SERVICE LOCATION: 480V 1600A 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-4B DATE: 03/27/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B REVISION 03/27/2024 C ELECTRICAL CALCULATIONS PV-4B ELECTRICAL CALCULATION SCALE: NTS 1 ID TYPICAL INITIAL CONDUCTOR LOCATION FINAL CONDUCTOR LOCATION CONDUCTOR CONDUIT PARALLEL CONDUCTORS CURRENT-CARRYING CONDUCTORS IN CONDUIT CONDUIT FILL PERCENT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT BASE AMP.DERATED AMP. TERM. TEMP. RATING LENGTH VOLTAGE DROP 1 4 ARRAY JUNCTION BOX-1 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 121FT 0.51% 2 4 ARRAY JUNCTION BOX-2 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 113FT 0.51% 3 4 ARRAY JUNCTION BOX-5 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 113FT 0.51% 4 4 ARRAY JUNCTION BOX-6 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 113FT 0.51% 5 4 ARRAY JUNCTION BOX-9 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 97FT 0.46% 6 4 ARRAY JUNCTION BOX-10 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 97FT 0.46% 7 4 ARRAY JUNCTION BOX-11 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 97FT 0.46% 8 4 ARRAY JUNCTION BOX-12 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 97FT 0.46% 9 3 ARRAY JUNCTION BOX-13 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 97FT 0.46% 10 3 ARRAY JUNCTION BOX-14 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 89FT 0.25% 11 3 ARRAY JUNCTION BOX-17 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 121FT 0.51% 12 3 ARRAY JUNCTION BOX-18 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 113FT 0.51% 13 1 JUNCTION BOX-1 INVERTER #1 10 AWG PV WIRE COPPER MIN 1.25" Dia EMT 4 8 29.47%N/A 10 AWG THWN-2, COPPER 0.76 (53°C)0.7 13.63A 17.03A 40A 21.28A 90°C 81FT 0.34% 14 1 JUNCTION BOX-2 INVERTER #1 10 AWG PV WIRE COPPER MIN 1.25" Dia EMT 4 8 29.47%N/A 10 AWG THWN-2, COPPER 0.76 (53°C)0.7 13.63A 17.03A 40A 21.28A 90°C 141FT 0.63% 15 1 JUNCTION BOX-5 INVERTER #3 10 AWG PV WIRE COPPER MIN 1.25" Dia EMT 4 8 29.47%N/A 10 AWG THWN-2, COPPER 0.76 (53°C)0.7 13.63A 17.03A 40A 21.28A 90°C 79FT 0.35% 16 1 JUNCTION BOX-6 INVERTER #3 10 AWG PV WIRE COPPER MIN 1.25" Dia EMT 4 8 29.47%N/A 10 AWG THWN-2, COPPER 0.76 (53°C)0.7 13.63A 17.03A 40A 21.28A 90°C 84FT 0.38% 17 1 JUNCTION BOX-9 INVERTER #5 10 AWG PV WIRE COPPER MIN 1.25" Dia EMT 4 8 29.47%N/A 10 AWG THWN-2, COPPER 0.76 (53°C)0.7 13.63A 17.03A 40A 21.28A 90°C 64FT 0.31% 18 1 JUNCTION BOX-10 INVERTER #5 10 AWG PV WIRE COPPER MIN 1.25" Dia EMT 4 8 29.47%N/A 10 AWG THWN-2, COPPER 0.76 (53°C)0.7 13.63A 17.03A 40A 21.28A 90°C 155FT 0.74% 19 1 JUNCTION BOX-11 INVERTER #6 10 AWG PV WIRE COPPER MIN 1.25" Dia EMT 4 8 29.47%N/A 10 AWG THWN-2, COPPER 0.76 (53°C)0.7 13.63A 17.03A 40A 21.28A 90°C 39FT 0.19% 20 1 JUNCTION BOX-12 INVERTER #6 10 AWG PV WIRE COPPER MIN 1.25" Dia EMT 4 8 29.47%N/A 10 AWG THWN-2, COPPER 0.76 (53°C)0.7 13.63A 17.03A 40A 21.28A 90°C 91FT 0.43% 21 1 JUNCTION BOX-13 INVERTER #7 10 AWG PV WIRE COPPER MIN 1.0" Dia EMT 3 6 39.54%N/A 10 AWG THWN-2, COPPER 0.76 (53°C)0.8 13.63A 17.03A 40A 24.32A 90°C 49FT 0.23% 22 1 JUNCTION BOX-14 INVERTER #7 10 AWG PV WIRE COPPER MIN 1.0" Dia EMT 3 6 39.54%N/A 10 AWG THWN-2, COPPER 0.76 (53°C)0.8 13.63A 17.03A 40A 24.32A 90°C 121FT 0.62% 23 1 JUNCTION BOX-17 INVERTER #9 10 AWG PV WIRE COPPER MIN 1.0" Dia EMT 3 6 39.54%N/A 10 AWG THWN-2, COPPER 0.76 (53°C)0.8 13.63A 17.03A 40A 24.32A 90°C 36FT 0.15% 24 1 JUNCTION BOX-18 INVERTER #9 10 AWG PV WIRE COPPER MIN 1.0" Dia EMT 3 6 39.54%N/A 10 AWG THWN-2, COPPER 0.76 (53°C)0.8 13.63A 17.03A 40A 24.32A 90°C 54FT 0.24% 25 1 INVERTER #1 TO #9 SOLAR LOAD CENTER 1/0 AWG THWN-2 COPPER MIN 1.5" Dia EMT 1 4 38.24%100A 8 AWG THWN-2, COPPER 0.76 (53°C)0.8 79.50A 99.37A 170A 103.36A 90°C 145FT 0.58% 26 1 SOLAR LOAD CENTER PV PRODUCTION METER 350 KCMIL THWN-2 COPPER MIN 2.5" Dia EMT 4 4 39.55%N/A 2/0 AWG THWN-2, COPPER 0.94 (31°C)0.8 715.50A 894.37A 4 x 310.0A 4 x 233.12A 75°C 36FT 0.10% 27 1 PV PRODUCTION METER SERVICE DISCONNECT 350 KCMIL THWN-2 COPPER MIN 2.5" Dia EMT 4 4 39.55%1000A 2/0 AWG THWN-2, COPPER 0.94 (31°C)0.8 715.50A 894.37A 4 x 310.0A 4 x 233.12A 75°C 10FT 0.03% 28 1 SERVICE DISCONNECT MAIN DISTRIBUTION PANEL 350 KCMIL THWN-2 COPPER MIN 2.5" Dia EMT 4 4 35.76%N/A N/A THWN-2, COPPER 0.94 (31°C)0.8 715.50A 894.37A 4 x 310.0A 4 x 233.12A 75°C 10FT 0.03% NORTH 1600A MAIN CIRCUIT BREAKER RATING: SERVICE INFO MAIN SERVICE VOLTAGE: MAIN SERVICE PANEL: MAIN SERVICE LOCATION: 480V 1600A NOTE: TAG NO 26, 27 & 28 HAVE FOUR PARALLEL SET OF 2.5" DIA CONDUIT AND EACH CONDUIT HAVE 4 CABLES (L1, L2, L3 & N) NOTE: INVERTERS #1, #2, #3, #4, #5, #6, #7, #8 & #9 HAVE SAME WIRE CALCULATIONS. NOTE: THERE WILL BE A SEPARATE GEC ROUTED FOR SERVICE DISCONNECT. 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-4C DATE: 03/27/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B REVISION 03/27/2024 C SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL ADANI SOLAR ASB-M10-535 (535W) VMP 41.64 V IMP 12.86 A VOC 49.12 V ISC 13.63 A TEMP. COEFF. VOC -0.29%/°C MODULE DIMENSION 89.21"(L) x 44.61"(W) PANEL WATTAGE 535W SPECIFICATIONS & NOTES PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 0.80 4-6 0.70 7-9 0.50 10-20 0.45 10-20 AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 2°C AMBIENT TEMP (HIGH TEMP 2%)31°C CONDUIT HEIGHT 0.5" ROOF TOP TEMP 90°C CONDUCTOR TEMPERATURE RATE 53°C MODULE TEMPERATURE COEFFICIENT OF VOC -0.29%/°C INVERTER SPECIFICATION MANUFACTURER / MODEL SUNNY TRIPOWER CORE1 62-US [480V] NOMINAL AC POWER 62500 W NOMINAL OUTPUT VOLTAGE 480 V NOMINAL OUTPUT CURRENT 79.5 A 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-5 DATE: 02/23/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B PLACARDS POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN. CAUTION! LABEL LOCATION: MAIN SERVICE PANEL & UTILITY METER& SUB PANEL, AC PANEL, AC DISCONNECT PLACARDS NOTES 1.CEC ARTICLES 690 AND 705 AND CEC SECTION R331 MARKINGS SHOW HEREON 2.ALL MARKINGS SHALL CONSIST OF THE FOLLOWING: A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING B.RED BACKGROUND COLOR WITH WHITE TEXT AND LINE WORK C.ARIAL FONT. 3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. 4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT USING POP-RIVETS OR SCREWS. 5.THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. 6.WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [CEC 110.21(8) FIELD MARKING]. 7.ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [CFC 605.11.1.3] CODE : PER CEC 690.54 PANEL BOARD ENERGIES FROM TWO SOURCES OF AC POWER SOLAR 715.5A AT 480V & UTILITY GRID 1600A AT 480V 1 Junction Box Scale: NTS 2 Solar Load Center Scale: NTS DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT 3 AC Disconnects Scale: NTS WARNING 4 Scale: NTS CAUTION POWER TO THIS SERVICE IS ALSO SUPPLIED FROM ON-SITE SOLAR/WIND GENERATION AC SYSTEM DISCONNECT CAUTION ALTERNATE POWER SUPPLY AC SYSTEM DISCONNECT WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CODE : PER CEC 110.27(C) & OSHA 1910.145(f)(7) !WARNING ELECTRICAL SHOCK HAZARD CODE : PER CEC 110.27(C) & OSHA 1910.145(f)(7) ! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CODE : PER CEC 690.13(B) ! WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! CODE : PER CEC 706.15(C)(4) and CEC 690.13(B) WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVER CURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR CODE : PER CEC 690.13(B) !WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! CODE : PER CEC 706.15(C)(4) and CEC 690.13(B) WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM! CODE : PER CEC 690.59 and CEC 705.12(D)(3) ! POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. CODE : PER CEC 705.12(B)(3)(2) WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CODE : PER CEC 110.27(C) and OSHA 1910.145(f)(7) !WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! CODE : PER CEC 706.15(C)(4) and CEC 690.13(B) WARNING SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTI WIRE BRANCH CIRCUITS ! CODE : PER CEC 706.15(C)(4) and CEC 690.13(B) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT CODE : PER CEC 690.13(B) RAPID SHUTDOWN FOR SOLAR PV SYSTEM CODE : PER CEC 690.56(C)(2) DO NOT DISCONNECT UNDER LOAD CODE : PER CEC 690.15(B) and CEC 690.33(D)(2) LABEL LOCATION: AC DISCONNECT (UTILITY REQUIREMENT) LABEL LOCATION: AC DISCONNECT (UTILITY REQUIREMENT) 5 Conduit Scale: NTS ! WARNING RACEWAY IS ENERGIZED WHENIN THE OPEN POSITION. DO NOT RELOCATE OR CUT ! WARNING FOR LINE-SIDE TAP: "THE SUM OF THE AMPERE RATINGS OF ALL OVER CURRENT DEVICES ON PANEL BOARDS, BOTH LOAD AND SUPPLY DEVICES, EXCLUDING THE RATING OF THE OVER CURRENT DEVICE PROTECTING THE BUS BAR, SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. PERMANENT WARNING LABELS SHALL BE APPLIED TO DISTRIBUTION EQUIPMENT." THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVER CURRENT DEVICES, EXCLUDING MAIN SUPPLY OVER CURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. LABEL PER CEC 690.56(C)- PROVIDE AT AC DISCONCECT FOR RAPID SHUTDOWN COMPLIANT SYSTEM SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS PER CODE: CEC 690.54 PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT 715.5 AMPS NOMINAL OPERATING AC VOLTAGE 480 VOLTS Main Service Panel (N) AC DISCONNECT ELECTRICAL ROOM (E) MAIN SWITCHBOARD (E) UTILITY METER (N) SOLAR LOAD CENTER (N) RAKE (TYP.) (N) PV MODULE (N) 9 x SUNNY TRIPOWER CORE1 62-US INVERTERS (ON ROOF) SLC MSBUMACD INV INV INV INV INV INV INV INV INV JB PVM GEN MS B T T T T (E) TRANSFORMER (E) MAIN SWITCHBOARD (E) 3 x TRANSFORMERS (E) GENERATOR PU L L M A N S T ELECTRICAL ROOM 2 E DEERE AVE 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-10 DATE: 02/23/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B CERTIFICATE 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-6 DATE: 02/23/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B EQUIPMENT SPECIFICATIONS 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-7 DATE: 02/23/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B EQUIPMENT SPECIFICATIONS 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-8 DATE: 02/23/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B EQUIPMENT SPECIFICATIONS 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-9 DATE: 02/23/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L REVISION 02/20/2024 A SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 02/23/2024 B EQUIPMENT SPECIFICATIONS 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 CARUSO TURLEY SCOTT structural engineers STRUCTURAL ENGINEERING EXPERTS PARTNERS Sandra Herd, SE, PE, LEED AP Thomas Morris, SE, LEED AP Richard Dahlmann, SE, PE Troy Turley, SE, PE, LEED AP Brady Notbohm, SE, PE PROFESSIONAL REGISTRATION 50 States Washington D.C. U.S. Virgin Islands Puerto Rico 1215 W. Rio Salado Pkwy. Suite 200 Tempe, AZ 85281 T: (480) 774-1700 F: (480) 774-1701 Job No.24-0242-2971.1 Sheet No.Cover By BDW/TET Date 3/26/24 CLIENT: 1600 Osgood Street North Andover, MA 01845 PROJECT: Medtronic 1851 E Deere Ave Santa Ana, CA 92705 GENERAL INFORMATION: BUILDING CODE: 2022 CBC, ASCE 7-16 With SEAOC PV1-2012 and PV2-2017 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Partner Name:SolarCo Energy Inc. Project Name:Medtronic Project Location:1851 E Deere Ave, Santa Ana, CA 92705, USA Racking System:clawFR 10 Degree Structural Calculations for Roof-Mounted Solar Array Submittal Release: Rev 2 Engineering Seal 03/20/2024 APPROVED FOR CONSTRUCTION 3/26/2024 TROY E.TURLEY 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 5.0 Design Loads - Wind (Cont.): 5.1.2 Global Wind Shear Summary Table: Mechanical attachments may be required for several reasons including building code, roof load limits and array shape. The table below provides the mechanical attachment requirements for each sub-array within this project.  Applied Load Resisting Load Code Check Sub- Array Name FL-D = Wind Uplift (lbs.) FD = Wind Drag (lbs.) DL = Total Dead Load (lbs.) Maximum Allowable Mechanical Attachment Strength (lbs.) Total MA Capacity (lbs.) Check Calculated Factor of Safety* Check 1.1 5,281 1,949 11,681 650 0 2.43 OK 2.2 12,696 4,668 34,016 650 12,350 4.01 OK 2.3 16,199 4,713 33,407 650 18,850 3.81 OK 2.4 9,346 3,815 26,060 650 9,750 4.05 OK 2.5 15,269 4,468 32,196 650 15,600 3.69 OK Total:58,791 lbs.19,613 lbs.137,360  56,550 lbs. Table 5.2 Summary of Mechanical Attachment Requirements * Back calculated factor of safety provided to determine factor of safety applied to dead load in lieu of 0.6 in ASCE7 equation 7, BACK CALCULATED FACTOR OF SAFETY = (DEAD LOAD+MECHANICAL ATTACHMENT)/(((.6)WIND DRAG /FRICTION)+(.6)WIND UPLIFT) 03/20/2024 APPROVED FOR CONSTRUCTION 10 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 6.0 Design Loads - Downward: 6.1 Downward Wind Load Calculation: WLin = qz * Am * GCP * cos θ Where: qz =19.25 psf (Ref. Section 3.1, Wind Load Data) Am =27.64 sq.ft.(Single Module Area)(Ref. Section 1.1, General Project Information) θ =8.99 deg.(Ref. Section 1.1, General Project Information) GCP =1.13 (Inward)(Proprietary Wind Tunnel Data) GCP =0.30 (Inward with snow)(ASCE 7-16 figure 30.3-5A) WLin(no snow) = 594 lbs./module WLin(with snow) = 158 lbs./module Contact Base by Location:                                                        Contact Pad by Information: 1 =South Distance Between C.C. outer Pads =12.5 in. 2 =Interior Typical Pad Area =9 sq.in. 3 =2nd from North 4 =North 6.2 Racking Dimensions for Point Loads: Inter-Module Support spacing (S) = 48.62 in. Inter-Column Support Spacing (L) = 41.34 in. Fig. 6.1 Typical Array Plan View (Section A-A) on Next Page 03/20/2024 APPROVED FOR CONSTRUCTION 11 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 6.0 Design Loads - Downward (Cont.): 6.2 Racking Dimensions for Point Loads (Cont.): Fig. 6.2 Section A-A 6.3 Point Load Summary:Notes: DLsys = 79 lbs./module -Base 2 repeat for larger width arrays. Total DL = (Varies on location and ballast quantity) SLm = 0 lbs./module WLin (no snow) = 594 lbs./module WLin (with snow) = 158 lbs./module Max Total Load Per Base (lbs.) load combinations (ASD) Location Base DL + Snow DL + 0.6 X Wlin DL + 0.75 X SLm + 0.75(0.6 X WLin) South 1 49 138 67 Interior 2 105 284 141 2nd From North 3 96 274 131 North 4 90 179 108 Table 6.1-A Max Total Load per Base (lbs.) Max Contact Pressure Table Per Base (psi) load combinations (ASD)# of Pads Location Base DL + Snow DL + 0.6 X Wlin DL + 0.75 X SLm + 0.75(0.6 X WLin) South 1 3 7 4 Interior 2 6 15 8 2nd From North 3 5 15 7 2 North 4 5 10 6 South 1 1 4 2 Interior 2 3 8 4 2nd From North 3 3 7 4 4 North 4 2 5 3 Table 6.1-B Max Point Load Summary (psi) 03/20/2024 APPROVED FOR CONSTRUCTION 12 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 7.0 Design Loads - Seismic: Seismic Calculations per ASCE 7-16, Chapter 11 - Seismic Design Criteria Chapter 13 - Requirements for Nonstructural Components 7.1 Seismic Load Data: Site Class :D (Ref. Project Information) Seismic Design Category :D (ASCE, Tables 11.6-1 and 11.6-2) Short Period Spectral Resp. (5%) (Ss) :1.266 (Ref. Project Information) 1s Spectral Response (5%) (S1) :0.454 (Ref. Project Information) Bldg. Seismic Imp. Factor (Ie) =1 (ASCE, Table 1.5-2) Site Coefficient (Fa) =1.2 (ASCE, Table 11.4-1) Site Coefficient (Fv) =1.8 (ASCE, Table 11.4-2) Adj. MCE Spec. Resp. (Short) (Sms) =Fa*Ss =1.519 (ASCE, Eqn. 11.4-1) Adj. MCE Spec. Resp. (1 sec.) (Sm1) =Fv*S1 =0.838 (ASCE, Eqn. 11.4-2) Short Period Spectral Response (Sds) =2/3(Sms) =1.013 (ASCE, Eqn. 11.4-3) One Second Spectral Response (Sd1) =2/3(Sm1) =0.559 (ASCE, Eqn. 11.4-4) Component Seismic Imp. Factor (Ip) =1 (ASCE, Sec. 13.1.3) Repsonse Modification Factor (Rp) =2.5 (ASCE, Table 13.6-1) Amplification Factor (ap) =1 (ASCE, Table 13.6-1) 7.2 Seismic Design Equations: * Frictional resistance due to the components weight may be used to resist lateral forces caused by seismic loads. 03/20/2024 APPROVED FOR CONSTRUCTION 13 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 7.0 Design Loads - Seismic (Cont.): 7.3 Lateral Seismic Force Check: The necessity to add mechanical attachments can arise for several reasons. Building code requirements, roof load limits and array shape all may come into play when determining their need. The table below provides the mechanical attachment requirements for each sub-array within this project. Nomenclature: WP = Sub-Array Weight FPL = Lateral Seismic Force FRL = Lateral Seismic Resisting Force Array Information Lateral Force Verification Results Sub- Array Name WP (lbs.) FPL (lbs.) FRL (lbs.) 0.7 FPL - FRL (lbs.) MA's Required Total MA Capacity (lbs.) MA's Provided Acceptable 1.1 11,681 5,679 2,660 1,315 0 0 0 Yes 2.2 34,016 16,537 0 11,576 18 12,350 19 Yes 2.3 33,407 16,241 0 11,368 18 18,850 29 Yes 2.4 26,060 12,669 0 8,868 14 9,750 15 Yes 2.5 32,196 15,652 0 10,956 17 15,600 24 Yes Totals:137,360 lbs 66,777 lbs.2,660 lbs.44,084 lbs.67 56,550 87 Table 7.1 -Summary of Mechanical Attachment Requirements * MA's Required = 0.7 FPL-FRL/MA strength 03/20/2024 APPROVED FOR CONSTRUCTION 14 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 7.0 Design Loads - Seismic (Cont.): 7.3.1 Seismic Displacement of Unattached Solar Arrays: Per ASCE 7-16, Section 13.6.12, the use of non-linear response history (NLRH) analysis is permitted to determine the seismic displacement of non-structural components located on the roof. μ =specific to each array, see table 7.3 Roof Pitch :specific to each array, see table 7.3 lp =1 for all arrays le =1 for all arrays PanelClaw, Inc. has engaged the services of a 3rd party consulting engineer to perform NLRH analysis on its clawFR product. Utilizing that analysis, and the report contained in the Appendix of this package, we are able to determine the displacement of the arrays during seismic events, for the system design life of 25 years. The distance, called Δ MPV, noted below represents the displacement due to the maximum seismic event with a 700 year MRI. The Δ MPV also incorporates the cumulative displacements, over the arrays design life, of smaller seismic events. As a company policy, PanelClaw, Inc., limits the use of this data to Δ MPV displacement of 48" or less. ΔMPV distances are derived from App. B, "Executive Summary: clawFR Seismic Displacement Demands of Unattached Arrays." Using the ΔMPV value above, ASCE 7-16 has adopted the following equations to set the minimum separation between unattached solar arrays and rooftop obstructions. Table 10.1 below lists the required separation per ASCE 7-16. REQUIRED ARRAY CLEARANCES PER ASCE 7-16 Condition #Condition Description Minimum Separation Equation 1 Between separate solar arrays of similar construction (0.5)(Mpv) 2 Between a solar array and a fixed object on the roof or solar array of different construction (Mpv) 3 Between a solar array and a roof edge with a qualifying parapet (Mpv) 4 Between a solar array and a roof edge without a qualifying parapet (2.0)(Mpv) >= 4 ft NOTE: YOU SHOULD PROVIDE SUFFICIENT SLACK IN ARRAY ELECTRICAL WIRING TO ACCOMMODATE ALL POTENTIAL ARRAY MOVEMENT. 03/20/2024 APPROVED FOR CONSTRUCTION 15 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 7.0 Design Loads - Seismic (Cont.): 7.3.1 Seismic Displacement of Unattached Solar Arrays (Cont.): Sub-Array Information Required Clearances per Condition (in) Min. Provided Clearance per Condition (in) Is Provided Clearance Acceptable (Y/N) Sub-Array Name(s) μ = Slope (deg) ΔMPV (in) 1 2 3 4 1 2 3 4 1 2 3 4 1.1 0.71 1 6 3 6 6 48 N/A 9 80 80 N/A Y Y Y Table 7.3 - Sub-Array predicted movement, required clearances, provided clearances, and acceptance 03/20/2024 APPROVED FOR CONSTRUCTION 16 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 7.0 Design Loads - Seismic (Cont.): 7.4 Vertical Seismic Force Check: Mechanical attachments may be required for several reasons including building code, roof load limits and array shape. The table below provides the mechanical attachment requirements for each sub-array within this project. Nomenclature: WP = Sub-Array Weight FPV = Vertical Seismic Force FRV = Vertical Seismic Resisting Force Array Information Vertical Force Verification Results Sub- Array Name WP (lbs.) FPV (lbs.) FRV (lbs.) 0.7 FPV - FRV (lbs.) MA's Required Total MA Capacity (lbs.) Total MA's Provided Acceptable 1.1 11,681 2,366 7,009 -5,352 0 0 0 Yes 2.2 34,016 6,890 20,410 -15,586 0 8,192 19 Yes 2.3 33,407 6,767 20,044 -15,307 0 11,773 29 Yes 2.4 26,060 5,279 15,636 -11,941 0 4,284 15 Yes 2.5 32,196 6,522 19,317 -14,752 0 9,948 24 Yes Total: 137,360 lbs. 27,824 lbs.82,416 lbs.-62,939 lbs.0 34,197 87 Table7.2 - Summary of Mechanical Attachment Requirements * MA's Required = 0.7 FPV - FRV/MA strength 03/20/2024 APPROVED FOR CONSTRUCTION 17 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix A Appendix A18 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix A19 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Table of Contents Section:Page # 03/20/2024 APPROVED FOR CONSTRUCTION 2 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1.0 Project Information 4 1.1 General 4 1.2 Building Information 4 1.3 Structural Design Information 5 2.0 Snow Load 6 2.1 Snow Load Data 6 2.2 Snow Load Per Module 6 3.0 Wind Load 7 3.1 Wind Load Data 7 3.2 Roof / Array Zone Map 7 3.3 Wind Design Equations 7 4.0 Design Loads - Dead 8 4.1 Dead Load of the Arrays 8 5.0 Design Loads - Wind 9 5.1.1 Global Wind Uplift Summary Table:9 5.1.2 Global Wind Shear Summary Table:10 6.0 Design Loads - Downward 11 6.1 Downward Wind Load Calculation 11 6.2 Racking Dimensions for Point Loads 11 6.3 Point Load Summary 12 7.0 Design Loads - Seismic 13 7.1 Seismic Load Data 13 7.2 Seismic Design Equations 13 7.3 Lateral Seismic Force Check:14 7.3.1 Seismic Displacement of Unattached Solar Arrays:15 7.4 Vertical Seismic Force Check:17 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix A20 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix A21 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix A22 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix A23 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix A24 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix B Appendix B25 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix B26 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix B27 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix B28 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix B29 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix: A. Wind Tunnel Tests and Load Analysis for PANELCLAW ROOF MOUNT 10° TILT SOUTH-FACING, CPP Project 11828, Dated 15 March 2019. B. Building Code and Technical data 03/20/2024 APPROVED FOR CONSTRUCTION 3 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix B30 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Appendix B31 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 1.0 Project Information: 1.1 General: Project Name:Medtronic Project Location:1851 E Deere Ave, Santa Ana, CA 92705, USA Racking System:clawFR 10 Degree Module:ADANI ASB-M10-144-535 Module Weight:61.73 lbs. Module Tilt:8.99 deg. Module Width:44.61 in. Module Length:89.21 in. Module Area:27.64 sq.ft. Ballast Block Weight:32.60 lbs. 1.2 Building Information: Roof Name Height (ft.)Parapet Height (ft.) Roof 1 20 5.0 Roof 2 30 4.0 Sub-Array Name Pitch (deg.)Membrane Material Coeff. of Friction (μ) 1.1 1 PVC 0.71 2.2 1 PVC 0.71 2.3 1 PVC 0.71 2.4 1 PVC 0.71 2.5 1 PVC 0.71 03/20/2024 APPROVED FOR CONSTRUCTION 4 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 1.0 Project Information (Cont.): 1.3 Structural Design Information: ASCE Code:ASCE 7-16 Building Code:2022 CBC Risk Cat.:II Basic Wind Speed (V):95 mph Exposure Category:C Ground Snow Load (Pg):0 psf Is:1 Site Class:D Short Period Spectral Resp. (5%) (Ss):1.266 1s Spectral Response (5%) (S1):0.454 Ie:1 Ip:1 03/20/2024 APPROVED FOR CONSTRUCTION 5 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 2.0 Snow Load: Snow Calculations per ASCE 7-16, Chapter 7 2.1 Snow Load Data: Ground Snow Load (Pg)=0.00 psf (ASCE, Figure 7.2-1) Exposure Factor (Ce)=1 (ASCE, Table 7.3-1) Thermal Factor (Ct)=1.2 (ASCE, Table 7.3-2) Importance Factor (Is)=1 (ASCE, Table 1.5-2) Flat Roof Snow Load (Pf) =0.7*Pg*Ce*Ct*Is=0.00 psf (ASCE 7.3-1) Min Snow Load for Low Slope Roof =Pg*Is =0.00 psf (ASCE 7.3.4) Snow Load on Array (SLA) =0.00 psf SLA Fig. 2.1 - Uniform Roof Snow Load on Array 2.2 Snow Load Per Module: Snow Load per Module (SLM) =Module Projected Area SLA Where; Module Projected Area (Amp) = Module Area * Cos(Module Tilt) Where; Module Area =27.64 sq.ft. Module Tilt =8.99 deg. Amp =27.30 sq.ft. SLM =   Amp     SLA   = 0.00     lbs. 03/20/2024 APPROVED FOR CONSTRUCTION 6 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 3.0 Wind Load: Wind Analysis per ASCE 7-16- Wind Tunnel Procedure, Chapter 31 3.1 Wind Load Data: Basic Wind Speed (Vult) =95 mph (ASCE, Figure 26.5-1A) Exposure Category:C (ASCE, Sec. 26.7.3) Topographic Factor (Kzt) =1 (ASCE, Fig. 26.8-1) Directionality Factor (Kd) =0.85 (ASCE, Table 26.6-1) Exposure Coefficient (Kz) =0.90 (ASCE, Table 26.10-1) Ground Elevation Factor (Ke) =1.00 (ASCE, Table 26.9-1) Velocity Pressure (qz) =0.00256*Kz*Kzt*Kd*Ke*V^2 =17.68 psf (ASCE, Eqn. 26.10-1) 3.2 Roof / Array Zone Map: Figure 3-1. South corner zones – 90-180° wind directions Figure 3-2. North corner zones – 0- 90° wind direction Roof Zone Map Dimensions per CPP Wind Tunnel Study Height (ft.)LB* (ft.)Velocity Pressure (qz) (psf) 20 20.00 17.68 30 30.00 19.25 *LB = Characteristic length per wind tunnel study 3.3 Wind Design Equations: FL = qz Aref GCL FL = sum of lift on panel and deflector. FD = qz Aref GCD FD = sum of drag on panel and deflector. FL - D Companion = qz Aref GCL - D Companion FL - D Companion = The accompanying uplift corresponding to maximum drag. Where qz = Velocity Pressure (Ref. Section 3.1, Wind Load) Aref = Module Area (Ref. Section 1.1, General) GCL GCD , GCL-D Companion= Vary and related to wind zone map (Proprietary Wind Tunnel Coefficients) 03/20/2024 APPROVED FOR CONSTRUCTION 7 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 4.0 Design Loads - Dead: There are two categories of dead load used to perform the structural analysis of the PanelClaw racking system; Dead Load of the Array (DLA) and Dead Load of the Components (DLC). DLA is defined as the weight of the entire array including all of the system components and total ballast used on the array. DLC is defined as the weight of the modules and the racking components within an array. The DLC does not include the ballast used to resist loads on this array. 4.1 Dead Load of the Arrays: Array Information Results Sub- Array Name Number of Modules DLC (lbs.) DLA (lbs.) DLC (lbs.)/module Sub- Array Area (ft.^2) Sub-Array Roof Pressure (DLC) (psf) Sub-Array Roof Pressure (DLA) (psf) Max Allowable Pressure on Roof (psf) Acceptable? 1.1 104 8,095 11,681 78 3,576 2.26 3.27 100.00 Yes 2.2 255 19,868 34,016 78 8,788 2.26 3.87 100.00 Yes 2.3 276 21,606 33,407 78 9,502 2.27 3.52 100.00 Yes 2.4 184 14,454 26,060 79 6,334 2.28 4.11 100.00 Yes 2.5 270 21,014 32,196 78 9,303 2.26 3.46 100.00 Yes Total:  1089 85,037 lbs.137,360 lbs. *Racking component weight range between 13 to 15 pounds per module Table 4.1 - Array Dead Loads and Roof Pressures 03/20/2024 APPROVED FOR CONSTRUCTION 8 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 5.0 Design Loads - Wind: 5.1.1 Global Wind Uplift Summary Table: The necessity to add mechanical attachments can arise for several reasons. Building code requirements, roof load limits and array shape all may come into play when determining their need. The table below provides the mechanical attachment requirements for each sub-array within this project.  Applied Load Resisting Load Code Check Sub- Array Name FL = Total Wind Uplift (lbs.) DL = Total Dead Load (lbs.) Maximum Allowable Mechanical Attachment Strength (lbs.) Total MA Capacity (lbs.) Calculated Factor of Safety* Check 1.1 10,794 11,681 N/A 0 1.80 OK 2.2 38,092 34,016 525 8,192 1.85 OK 2.3 43,881 33,407 525 11,773 1.72 OK 2.4 28,647 26,060 525 4,284 1.77 OK 2.5 41,219 32,196 525 9,948 1.70 OK Total:162,633 lbs.137,360 lbs. 34,197 lbs. Table 5.1 Summary of Mechanical Attachment Requirements * Back calculated factor of safety provided to determine factor of safety applied to dead load in lieu of 0.6 in ASCE 7-16 equation 7, BACK CALCULATED FACTOR OF SAFETY = (DEAD LOAD+MECHANICAL ATTACHMENT)/(.6)WIND LOAD 03/20/2024 APPROVED FOR CONSTRUCTION 9 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Prepared by: NS Structural Engineering, Inc. for MEDTRONICS PV ROOFTOP PROJECT FEASIBILITY STUDY & ANCHORAGE DESIGN MARCH 26, 2024 STRUCTURAL DRAWINGS & CALCULATIONS 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Scope of Work: NSSE Scope of work includes the following items: 1. Verification of (E) Roof Framing due to Panelclaw PV System 2. Anchorage of (N) Panelclaw system to (E) Built Up Roof Deck References: ASCE 7-16/CBC 2022 PanelClaw Calculation Package PanelClaw Construction Set Drawings Medtronics PV Project - Feasibility Study DATE: Summary: The purpose of this roof qualification report is to show that by addition of 137,360 lbs of solar modules (1,089 total) and racking system to the roof as shown on sheet PV-2 of the panelclaw drawings, will not require strengthening existing framing members due to vertical loads as well as triggering a seismic upgrade based on CBC. We have included in this qualification report the calculations for the above conclusions and recommendations. We recommend that the final PV layout and all details for the support of the proposed PV solar panels be reviewed by NS Structural Engineering, Inc. prior to construction. In general, NS Structural Engineering, Inc. lateral analysis is based on the final PV layout to be installed uniformly throughout the roof area to avoid any mass irregularities to the performance of the building due to lateral loads. A roofing report for the PV installation for the building was not provided. NSSE takes no responsibility for the (E) roofing conditions. NS STRUCTURAL ENGINEERING, INC MADE BY: JL 4642 Rockland Place La Canada Flintridge, CA 91011 CHECKED BY: NS PAGE NO. 1 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Design Criteria Roof Dead Loads (E) Built Up Roof - 4 ply 1/2" Plywood 2x4 @ 24" O.C. 4x12 Misc. GLB 5.125x27 Solar Dead Loads Solar Panels (Max Array Load) Ballast Weight (As Occurs per Plan View) On Module Base Spacing "S" Between Module Base Spacing "L" Live Loads Tributary Area =LL = 2x4 DF#2 Tributary Area =LL = 4x12 Tributary Area =LL = GLB 5.125x27 Wind Load Downward Wind Load 4x12 & (E) GLB 1.1 psf Medtronics PV Project - Feasibility Study - Roof 2 DATE: 3.0 psf 1.5 psf NS STRUCTURAL ENGINEERING, INC MADE BY: JL 4642 Rockland Place La Canada Flintridge, CA 91011 CHECKED BY: NS PAGE NO. 10 32.60 lbs 4.09 ft 3.44 ft Before Solar 16.0 ft²20.0 psf 0.6 psf 2.0 psf 5.1 psf 1.5 psf 4.11 psf 8.1 psf 9.6 psf 160.0 ft²20.0 psf * No Live load is applied underneath modules due to being less than 24" from the roof surface. Live load is only applied at walkway locations and is averaged over solar array area. 9.6 psf 970.0 ft²12.0 psf 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Check Existing Roof Framing Check 2x4 RR @ 24" O.C. Beam Properties Max Simple Span L1 =(Simple Span Distance) Tributary Spacing tw =(Member Spacing) Section Modulus S =bd2/6 Allowable Bending Stress Fb = DF #2 Modulus of Elasticity E = Duration Factors CD = Dead Load CD = Live Load CD = Wind Load Size Factor Cf = Repetitive Factor Cr = Allowable Moment M'Dead =Sx * (Fb * CD * CF * Cr)= M'Live =Sx * (Fb * CD * CF * Cr)= M'Wind =Sx * (Fb * CD * CF * Cr)= NS PAGE NO. 11 Medtronics PV Project - Feasibility Study - Roof 2 DATE: NS STRUCTURAL ENGINEERING, INC MADE BY: JL 4642 Rockland Place La Canada Flintridge, CA 91011 CHECKED BY: 1.25 1.6 1.5 1.15 357 lb-ft 495 lb-ft 7.71 ft 2.0 ft 3.1 in³ 900.0 psi 1,400.0 ksi 0.9 634 lb-ft 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Check 2x4 RR @ 24" O.C. Solar + Ballast Dead Load DLE =wDL_E =PDL = @ Live Load LL =wLL = Wind Load WL =PWL = @ Module Weight + Racking = lbs Note 1: A minimum of 1/4 of the Module + Racking Weight will be at the oppose end of the Base Note 2: Module wind loads shall be split equally by both ends of the base Reaction 1 = lbs Reaction 2 = lbs Dead Load DLE =wDL_E =PDL = @ Live Load LL =wLL = Wind Load WL =PWL = @ Moment MDL_1 = lb-ft wDL * L2 / 8 MDL_2 = lb-ft PDL * 2.14' MLL = lb-ft MWL = lb-ft PWL * 2.14' 1. LC. 1.0DL Required Moment MDL = lb-ft Allowable Moment MAll = lb-ft Interaction Check DCR = 2. LC. DL+0.6WL Required Moment MDL+0.6WL = lb-ft Allowable Moment MAll = lb-ft Interaction Check DCR =< 1.05 Okay1.00 74.3 211.4 0.0 349.0 285.7 356.6 0.80 634.7 633.9 NS STRUCTURAL ENGINEERING, INC MADE BY: JL 4642 Rockland Place La Canada Flintridge, CA 91011 CHECKED BY: NS PAGE NO. 12 78 85.5 19.5 5.0 psf 10.00 plf 98.8 lbs 2.14 ft 0.0 psf 0.0 plf 9.6 psf 163 lbs 2.14 ft 2.14 ft 0.0 psf 0.0 plf 9.6 psf 179 lbs 2.14 ft Roofing 5.0 psf 10.00 plf 105.0 lbs Medtronics PV Project - Feasibility Study - Roof 2 DATE: 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Load Comparison - Purlin 4x12 DLE LL Allowable Distributed Loads / 1.25 * 0.9 = (Dead Load) 1. DLE + LL / 1.25 * 1.25 =(Live Load) / 1.25 * 1.6 = (Wind Load) Dead Load DLNew = DL Wind Load 0.6WL = 0.6WL Live Load LL = New Load Combinations 1. DLE + DLN 2. DLE + DLN + LL 3. DLE + DLN + WL < 1.05 Okay 4. DLE + DLN + 0.75(LL+WL) Load Comparison - GLB DLE LL Allowable Distributed Loads / 1.25 * 0.9 = (Dead Load) 1. DLE + LL / 1.25 * 1.25 =(Live Load) / 1.25 * 1.6 = (Wind Load) Dead Load DLNew = DL Wind Load 0.6WL = 0.6WL Live Load LL = New Load Combinations 1. DLE + DLN 2. DLE + DLN + LL 3. DLE + DLN + WL < 1.05 Okay 4. DLE + DLN + 0.75(LL+WL) NS STRUCTURAL ENGINEERING, INC MADE BY: JL 4642 Rockland Place La Canada Flintridge, CA 91011 CHECKED BY: NS PAGE NO. 13 28.1 psf Medtronics PV Project - Feasibility Study - Roof 2 DATE: 8.1 psf Purlin DCR 4.11 psf 9.60 psf 5.00 psf * Conservative. No Live load is applied underneath modules due to being less than 24" from the roof surface. 12.0 psf 15.6 psf 21.6 psf 21.6 psf 27.7 psf 4.11 psf 28.1 psf 20.3 psf 36.0 psf 9.6 psf 23.20 psf 0.64 12.25 psf 0.60 17.25 psf 0.61 21.85 psf 0.61 20.0 psf 18.74 psf 0.87 23.34 psf 0.84 24.69 psf 0.89 9.60 psf 5.00 psf * Conservative. No Live load is applied underneath modules due to being less than 24" from the roof surface. Purlin DCR 13.74 psf 0.88 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Address: 1851 E Deere Ave, Santa Ana, CA 92705 Roof Mass: Per As-Builts Description Flat Roof Wall Mass 7.5" Concrete Wall Building Height (+4'-0" Parapet) Description Exterior Walls Interior Walls Total Seismically Involved Mass Wtotal =WRoof +WWalls = Pallow =0.1 * Wtotal = Total Provided Weight on Rooftop, WDemand = = DCR =Wdemand / Pallow = 9.6 psf Area Weight 60,700 ft² 584,797 lbs 93.8 psf CHECKED BY: NS PAGE NO. 14 Medtronics PV Project - Feasibility Study - Roof 2 DATE: NS STRUCTURAL ENGINEERING, INC MADE BY: JL 4642 Rockland Place La Canada Flintridge, CA 91011 0.80 0.0 ft 0.00 ft 0 lbs 1,561,672 lbs 156,167 lbs 125,679 lbs 30.0 ft Perimeter/Length Tributary Height Weight 1042.0 ft 10.00 ft 976,875 lbs 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Screw Anchorage Calculation No. of Screws N = Case 1: 0.6DL+0.6WL V = lbs Vscrew = lbs / Screw Uplift = lbs T1_screw = lbs / Screw Due to Uplift M = lb-in s = in Effective Group Couple Distance based on (8) Screws T2_screw = lbs / Screw Due to Overturning Tscrew = lbs Case 2: DL+0.7EQ V = lbs Vscrew = lbs / Screw Uplift = lbs T1_screw = lbs / Screw Due to Uplift M = lb-in s = in Effective Group Couple Distance based on (8) Screws T2_screw = lbs / Screw Due to Overturning Tscrew = lbs NS STRUCTURAL ENGINEERING, INC MADE BY: JL 4642 Rockland Place La Canada Flintridge, CA 91011 CHECKED BY: NS PAGE NO. 15 0 59 Medtronics PV Project - Feasibility Study - Anchorage DATE: 8 0 0 176 176 610 76.3 0 0 1983 11 469 58.6 0 11 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Check #15 Screw Case 1: LC. 0.6DL - 0.6WL Screw Reactions: Horizontal Fx =lbs Vertical Py =lbs Resultant R =lbs Angle α= atan(Py/Fx) =°= Allowable Shear z' = lbs Allowable Withdrawl W'p = lbs Shear + Withdrawl z'α = lbs W'p x z' /((W'p x cos(α))^2)+(z' x sin(α))^2)) Capacity R /(n * z'α) =OK Case 2: DL +0.7EQ Screw Reactions: Horizontal Fx =lbs Vertical Py =lbs Resultant R =lbs Angle α= atan(Py/Fx) =°= Allowable Shear z' = lbs Allowable Withdrawl W'p = lbs Shear + Withdrawl z'α = lbs W'p x z' /((W'p x cos(α))^2)+(z' x sin(α))^2)) Capacity R /(n * z'α) =OK 1.6 0 PAGE NO. 16 DATE: NS STRUCTURAL ENGINEERING, INC MADE BY: JL 4642 Rockland Place La Canada Flintridge, CA 91011 CHECKED BY: NS 151 234 234 59 59 90.0 0.25 76 176 192 66.6 1.2 151 234 215 0.89 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Conditions for Panels Being Classified as Exposed are as follows Distance from Roof Perimeter to Edge of Array d1 < ft And Max Inter Array Spacing d1 > ft 4h2 Or Max Inter Panel Spacing d2 < ft 4h2 Yes or No Exposed Panels Zone 1 Zone 2 Zone 3 Building And Solar Panel Variables Roof Slope < 7° Panel Area TA 27.6 ft² CHECKED BY: NS PAGE NO. 2 Medtronics PV Project - Feasibility Study - Roof 1 DATE: NS STRUCTURAL ENGINEERING, INC MADE BY: JL 4642 Rockland Place La Canada Flintridge, CA 91011 Parapet Height hpt 5.0 ft Risk Category II Building Height h 20.0 ft Panel Tilt 10° C Width of Building (Shortest) WS 233.00 ft Importance Factor 1 Width of Building (Longest) WL 276.00 ft Wind Speed V 95 mph 10 3.65 3.65 Yes Yes Yes Panel Chord Length Lp 3.72 ft Exposure Category Panel Clearance h2 0.91 ft Panel Weight Wt 61.73 lbs 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Design Wind Pressure (Purlin) Wind Pressure P = where,qh = = Design Wind Speed V = Velocity Pressure Coefficient Kz = Topographic Factor Kzt = Wind Directionality Factor Kd = Ground Elevation Factor Ke = Net Pressure Coefficient GCrn = Normalized Wind Area An = = Lb = = * Note: Wind Load is based off tributary area of Purlin * Based on Fig. 29.4-7 (γp)= = (γc)= = (γE)= Zone 3 Zone 2 Zone 1 * Min. Wind Pressure = 16 psf (LRFD), 9.6 psf (ASD) Zone 3 Zone 2 Zone 1 * Min. Wind Pressure = 16 psf (LRFD), 9.6 psf (ASD) NS STRUCTURAL ENGINEERING, INC MADE BY: JL 4642 Rockland Place La Canada Flintridge, CA 91011 CHECKED BY: NS PAGE NO. 3 95 mph Fig. 26.5-1A 0.90 26.10.1 1 26.8.2 Medtronics PV Project - Feasibility Study - Roof 1 DATE: qh*GCrn Section 0.00256KzKztKdKeV2 17.7 psf 26.10.2 701.3 ft²Fig. 29.4-7 min(0.4(hWL)0.5,h,Ws) 20.0 ft Table 1: (GCrn)nom 0.85 26.6 1 26.9 (γp)(γc)(γE)(GCrn)nom 29.4.3 Roof Zone:0°  w  5°5°  w  15°(GCrn)nom for w 1 0.287 0.471 0.38 [1000/max(Lb,15)2]*TA min(1.2,0.9+hpt/h) 1.150 max(0.6+0.06Lp,0.8) 0.82 1.5 (Uplift) 2 0.366 0.527 0.45 3 0.402 0.653 0.53 13.24 psf 8.82 psf 7.94 psf 5.29 psf 11.20 psf 7.47 psf 6.72 psf 4.48 psf 1.0 (Downforce) Wind Pressure (Exposed) LRFD ASD Uplift Downforce Uplift Downforce 9.52 psf 6.34 psf 5.71 psf 3.81 psf Wind Pressure (Non-Exposed) LRFD ASD Uplift Downforce 7.47 psf 7.47 psf 4.48 psf 4.48 psf 6.34 psf 6.34 psf 3.81 psf 3.81 psf Uplift Downforce 8.82 psf 8.82 psf 5.29 psf 5.29 psf 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Design Criteria Roof Dead Loads PVC Membrane 4" Insullation 1-1/2" x 18 GA Metal Deck Misc. W14x22 W24x76 Solar Dead Loads Solar Panels (Max Array Load) Ballast Weight (As Occurs per Plan View) On Module Base Spacing "S" Between Module Base Spacing "L" Live Loads Tributary Area = LL = Metal Deck Tributary Area = LL = W14x22 Tributary Area = LL = W24x76 Wind Load Downward Wind Load (Purlins & Girder) Medtronics PV Project - Feasibility Study - Roof 1 DATE: 4642 Rockland Place La Canada Flintridge, CA 91011 CHECKED BY: NS PAGE NO. 4 NS STRUCTURAL ENGINEERING, INC MADE BY: JL 2.0 psf 3.30 psf Before Solar 4.05 ft 3.44 ft 6.0 psf 2.9 psf 2.5 psf 13.9 psf 16.4 psf 11.4 psf 0.5 psf 2.5 psf 32.60 lbs * No Live load is applied underneath modules due to being less than 24" from the roof surface. Live load is only applied at walkway locations and is averaged over solar array area. 9.6 psf -20.0 psf 280.5 ft²18.4 psf 1323.4 ft²12.0 psf 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Check 1 1/2" x 18 GA. Metal Deck Max Span L = ft Deck Sect. Mod. Sx =in3 / ft Tributary Width tw = ft (E) Roof Dead Load wDL = psf * ft = plf Roof Live Load wLL = psf * ft = plf (N) PV Dead Load PDL = lbs @ ft (N) PV Wind Load PWL = lbs @ ft Moment in Deck MDL = lb-ft wDL * L2 / 8 MDL = lb-ft PDL * 2.28' MLL = lb-ft wLL * L2 / 8 MWL = lb-ft PWL * 2.28' Total Moment M = lb-ft = lb-in Section Modulus S =in3 Bending Stress fb = psi All. Bending Stress fb = psi Fy = 50 ksi DCR = Medtronics PV Project - Feasibility Study - Roof 1 DATE: NS4642 Rockland Place La Canada Flintridge, CA 91011 CHECKED BY: 9170.1 5PAGE NO. 12.0 0.0 JLNS STRUCTURAL ENGINEERING, INC MADE BY: 8.83 0.314 1.50 8 1.50 0.0 1.50 0.471 19,469 29,940 0.650 \ Therefore, 18 GA MTL Deck is Good at All Locations 180.0 2.28 410 104.0 2.28 117 237 0 764 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Load Comparison - Steel Beam DLE LL * Conservative 1. DLE + LL Dead Load DLNew =DL Wind Load 0.6WL =0.6WL Live Load LL = New Load Combinations 1. DLE + DLN 2. DLE + DLN + LL 3. DLE + DLN + WL < 1.05 Okay 4. DLE + DLN + 0.75(LL+WL) Load Comparison - Girder DLE LL * Conservative 1. DLE + LL New Design Loads Max Base Reaction DL = Max Base Reaction 0.6WL = Live Load LL = New Load Combinations 1. DLE + DLN 2. DLE + DLN + LL 3. DLE + DLN + WL < 1.05 Okay 4. DLE + DLN + 0.75(LL+WL) *No Live load is applies undearth modules due to being less than 24" from the roof surface. 28.4 psf DCR 16.4 psf 12.0 psf 3.30 psf 9.60 psf 0.00 psf 29.34 psf 1.03 26.94 psf 0.53 0.83 3.30 psf 9.60 psf * No Live load is applied underneath modules due to being less than 24" from the roof surface. 0.53 Purlin 17.22 psf 0.00 psf 13.9 psf 18.4 psf 32.3 psf JL NS 6 NS STRUCTURAL ENGINEERING, INC MADE BY: DATE:Medtronics PV Project - Feasibility Study - Roof 1 4642 Rockland Place La Canada Flintridge, CA 91011 CHECKED BY: PAGE NO. 0.76 26.82 psf 24.42 psf 17.22 psf 0.95 Glulam DCR 19.74 psf 0.69 19.74 psf 0.69 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Address: 1851 E Deere Ave, Santa Ana, CA 92705 Roof Mass: Per As-Builts Description Flat Roof Wall Mass Building Height (+ 5' Parapet) Description Exterior Walls Interior Walls Total Seismically Involved Mass Wtotal =WRoof +WWalls = Pallow =0.1 * Wtotal = Total Provided Weight on Rooftop, WDemand = = DCR =Wdemand / Pallow = DATE: JL NS 7 MADE BY: 4642 Rockland Place La Canada Flintridge, CA 91011 CHECKED BY: PAGE NO. 73,650 lbs 0.0 ft 0.00 ft 0 lbs 9,500 ft² 156,148 lbs 15.0 psf 20.0 ft Perimeter/Length Tributary Height Weight 229,798 lbs 22,980 lbs 11,811 lbs 0.51 491.0 ft 10.00 ft 16.4 psf Area Weight NS STRUCTURAL ENGINEERING, INC Medtronics PV Project - Feasibility Study - Roof 1 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Conditions for Panels Being Classified as Exposed are as follows Distance from Roof Perimeter to Edge of Array d1 < ft And Max Inter Array Spacing d1 > ft 4h2 Or Max Inter Panel Spacing d2 < ft 4h2 Yes or No Exposed Panels Zone 1 Zone 2 Zone 3 NS STRUCTURAL ENGINEERING, INC MADE BY: JL 4642 Rockland Place La Canada Flintridge, CA 91011 CHECKED BY: NS PAGE NO. 8 Building Height h 30.0 ft Panel Tilt 10° Medtronics PV Project - Feasibility Study - Roof 2 DATE: Building And Solar Panel Variables Roof Slope < 7° Panel Area TA 27.6 ft² Width of Building (Longest) WL 322.00 ft Wind Speed V 95 mph Parapet Height hpt 4.0 ft Risk Category II Wt 61.73 lbs Panel Chord Length Lp 3.72 ft Exposure Category C Width of Building (Shortest) WS 199.00 ft Importance Factor 1 15 3.65 3.65 Yes Yes Yes Panel Clearance h2 0.91 ft Panel Weight 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 Design Wind Pressure (4x) Wind Pressure P = where,qh = = Design Wind Speed V = Velocity Pressure Coefficient Kz = Topographic Factor Kzt = Wind Directionality Factor Kd = Ground Elevation Factor Ke = Net Pressure Coefficient GCrn = Normalized Wind Area An = = Lb = = * Note: Wind Load is based off tributary area of Purlin * Based on Fig. 29.4-7 (γp)= = (γc)= = (γE)= Zone 3 Zone 2 Zone 1 * Min. Wind Pressure = 16 psf (LRFD), 9.6 psf (ASD) Zone 3 Zone 2 Zone 1 * Min. Wind Pressure = 16 psf (LRFD), 9.6 psf (ASD) NS STRUCTURAL ENGINEERING, INC MADE BY: JL 4642 Rockland Place La Canada Flintridge, CA 91011 CHECKED BY: NS PAGE NO. 9 95 mph Fig. 26.5-1A 0.90 26.10.1 1 26.8.2 Medtronics PV Project - Feasibility Study - Roof 2 DATE: qh*GCrn Section 0.00256KzKztKdKeV2 17.7 psf 26.10.2 177.8 ft²Fig. 29.4-7 min(0.4(hWL)0.5,h,Ws) 30.0 ft Table 1: (GCrn)nom 0.85 26.6 1 26.9 (γp)(γc)(γE)(GCrn)nom 29.4.3 Roof Zone:0°  w  5°5°  w  15°(GCrn)nom for w 1 0.541 0.791 0.67 [1000/max(Lb,15)2]*TA min(1.2,0.9+hpt/h) 1.033 max(0.6+0.06Lp,0.8) 0.82 1.5 (Uplift) 2 0.708 1.024 0.87 3 0.800 1.249 1.02 23.10 psf 15.40 psf 13.86 psf 9.24 psf 19.53 psf 13.02 psf 11.72 psf 7.81 psf 1.0 (Downforce) Wind Pressure (Exposed) LRFD ASD Uplift Downforce Uplift Downforce 15.02 psf 10.02 psf 9.01 psf 6.01 psf Wind Pressure (Non-Exposed) LRFD ASD Uplift Downforce 13.02 psf 13.02 psf 7.81 psf 7.81 psf 10.02 psf 10.02 psf 6.01 psf 6.01 psf Uplift Downforce 15.40 psf 15.40 psf 9.24 psf 9.24 psf 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 SCOPE OF WORK: NSSE SCOPE OF WORK INCLUDES THE FOLLOWING ITEMS: 1.VERIFICATION OF (E) ROOF FRAMING DUE TO PANELCLAW PV SYSTEM 2.ANCHORAGE OF (N) PANELCLAW PV SYSTEM TO (E) BUILT UP ROOF DECK SCALE: N.T.S. PANELCLAW ROOFTOP ATTACHMENT @ BUILT UP ROOF SCALE: N.T.S. PROJECT NAME: MEDTRONICS PV PROJECT DATE: 03/26/2024 SK-1 FIBERTIGHT MEMBRANE (BY OTHERS)(E) BUILT UP ROOF (E) 2X @ 24" O.C. 41 8" 51 2" TYP. PANELCLAW RACK U-ANCHOR 2400 (DESIGNED BY OTHERS) (8) #15 PHILLEP HEAD DEKFAST DF-#15-PH3 SCREWS PANELCLAW RACK U-ANCHOR 2400 (DESIGNED BY OTHERS) (E) 12" PLYWOOD (SEE NOTE 5) SEE NOTE 1 (8) #15 PHILLEP HEAD DEKFAST DF-#15-PH3 SCREWS NOTES: 1. SCREWS SHALL EXTEND A MINIMUM OF 3 4" OR THREE THREADS PAST BOTTOM OF PLYWOOD, WHICHEVER IS GREATER. 2. ALL EXPOSED WOOD OR STEEL SHALL BE WEATHER PROTECTED. 3. SCREWS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 4. CONTRACTOR SHALL VERIFY U-ANCHOR COMPATIBILITY WITH (E) ROOFTOP MEMBRANE PRIOR TO INSTALLATION. 5. CONTRACTOR SHALL VERIFY THAT (E) ROOF PLYWOOD/SUBSTRATE IS FREE OF DAMAGE AND REMAINS IN NEAR INSTALLATION CONDITION. 1851 E Deere Ave - 101118504 & 20182282 4/11/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-0 DATE: 07/03/2024 REVDATE DESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , C A 9 2 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 05/31/2024 F REVISION 06/20/2024 G REVISION 06/20/2024 H REVISION 06/26/2024 I REVISION 07/03/2024 J REVISION 09/05/2024 K REVISION 09/27/2024 L COVER PAGE 1 2 BUILDING PHOTO VICINITY MAP SCALE: NTS PV-0 PV-0 SCALE: NTS PROJECT SITE SCOPE OF WORK: TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM LOCATED AT 1851 E DEERE AVE, SANTA ANA, CA 92705, USA. THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. SYSTEM RATING 582.62 kWDC 562.50 kWAC SHEET INDEX PV-0 COVER PAGE PV-1 SITE PLAN PV-2 ROOF PLAN & MODULES PV-2A STRING LAYOUT & BOM PV-3 & PV-3A ATTACHMENT DETAILS PV-3B TAP DETAIL PV-4 & PV-4A ELECTRICAL LINE DIAGRAM PV-4B ELECTRICAL CALCULATIONS PV-4C SPECIFICATIONS & NOTES PV-5 SIGNAGE PV-6+EQUIPMENT SPECIFICATIONS PV-10 CERTIFICATE PV-11 FAULT CURRENT CALCULATIONS PC-1 TO PC-13 REPORT GOVERNING CODES 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA ENERGY EFFICIENCY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA ADMINISTRATIVE CODE EQUIPMENT SUMMARY 1089 ADANI SOLAR ASB-M10-535 (535W) MODULES 9 SUNNY TRIPOWER CORE1 62-US [480V] INVERTERS AHJ NAME : SANTA ANA CITY PROJECT SITE GENERAL NOTES: · THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE MODIFICATIONS IN CONSTRUCTION DETAILS. · ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR INSTALLATION OF ANY EQUIPMENT AT SITE. ·CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. · CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL COMPENSATION. · DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST. · THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND COMPLETION OF THE WORK WITH APPROVED MATERIALS. · NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE ARCHITECT. · CONTRACTOR SHALL OBTAIN BUILDING PERMIT. NO WORK TO START UNLESS BUILDING PERMIT IS PROPERLY DISPLAYED. · ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE WITH THE REQUIREMENTS OF THE CA BUILDING CODE, THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. · IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. · THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE LOCAL LAWS & REGULATIONS. · THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. · CONTRACTORS SHALL OBTAIN FIRE CERTIFICATE UPON COMPLETION OF WORK. WIRING AND CONDUIT NOTES: · ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE APPLICATIONS · ALL PV CABLES AND HOMERUN WIRES BE #10AWG *USE-2, PV WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED · ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [REF. TO CEC 2022] FOR MULTIPLE CONDUCTORS · ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE DERATED ACCORDING TO [CEC 2022] BLACK ONLY** · EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES · PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 600V PER CEC 2022 OR 1000V PER CEC 2022 · WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS · ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION · VOLTAGE DROP LIMITED TO 3% FOR DC CIRCUITS AS WELL AS FOR AC CIRCUIT · AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BROWN, PHASE B OR L2- ORANGE, PHASE C OR L3- YELLOW,NEUTRAL- WHITE/GRAY ELECTRICAL NOTES: · THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE INSTALLED ONLY BY QUALIFIED PEOPLE. A QUALIFIED PERSON IS ONE WHO HAS SKILLS AND KNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OF THE ELECTRICAL EQUIPMENT AND INSTALLATIONS AND HAS RECEIVED SAFETY TRAINING TO RECOGNIZE AND AVOID THE HAZARDS INVOLVED. (CEC 2022) · LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. FOR A LINE SIDE TAP CONNECTION, UTILITY NEEDS TO BE NOTIFIED WELL IN ADVANCE TO COORDINATE BUILDING ELECTRICAL SHUT OFF. · NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC. SUBCONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONS AND THE COORDINATION REQUIREMENTS OF OTHER TRADES. ·ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TO QUALIFIED PERSONNEL. ·ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WATERTIGHT AND APPROVED FOR USE IN WET LOCATIONS. (CEC 2022). ·WIRING METHODS FOR PV SYSTEM CONDUCTORS AREN'T PERMITTED WITHIN 10 IN. OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE LOCATED DIRECTLY BELOW THE ROOF SURFACE THAT'S COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT WIRING ·BACK-FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. ·ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARE LISTED AS UV RESISTANT. ·CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS IN CEC 2022 ·MEASURE THE LINE-TO-LINE AND LINE-TO-NEUTRAL VOLTAGE OF ALL SERVICE ENTRANCE CONDUCTORS PRIOR TO INSTALLING ANY SOLAR EQUIPMENT. ·THE CITY OF SANTA ANA WILL REQUIRE A THIRD-PARTY FIELD-EVALUATION-BODY THAT IS NATIONAL RECOGNIZED TESTING LABORATORY QUALIFIED TO EVALUATE AND PROVIDE A NEW FIELD LISTING FOR THE MODIFIED SERVICE EQUIPMENT. A REPORT PREPARED BY THE FEB MUST BE GIVEN TO THE CITY INSPECTOR FOR APPROVAL. ***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. *** Revision to 20182282 APPROVALS: ELECT - M. Smith 1851 E Deere Ave 11/13/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 2.3 ROOF INFORMATION ROOF HEIGHT (FT)30.00 PARAPET HEIGHT (FT) 4.0 ROOF TILT (DEG) 1 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 180 MODULE POWER (W) 535 ARRAY OUTPUT (Kw) 96.3 ARRAY AZIMUTH 220 PART QUANTITIES ITEM QTY Base 406 Module Connector 360 Rail 519 Cam 360 Cam Claw 360 Deflector 180 Base Pad 0 Ballast Block 322 Mechanical Attachment 14 LOADING DETAILS SINGLE MODULE WT (LB) 61.7 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 24526 ARRAY AREA (SQ. FT)6202 ARRAY LOAD (PSF) 3.95 ARRAY CLEARANCES PER ASCE 7 CONDITION 1 (in.) N/A CONDITION 2 (in.) N/A CONDITION 3 (in.) N/A CONDITION 4 (in.) N/A APPROVED FOR CONSTRUCTION SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA BALLAST LAYOUT - 2.3 PC-103 24.09.26.0 v3.0.9405.9.1 CM BALLAST LAYOUT - 2.3 PC-10 3 As - B u i l t AD 20 2 4 - 1 0 - 1 6 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 1/6" = 1'-0" 22 2 2 1 2 1 1 2 2 3 1 2 1 1 2 2 2 1 2 1 2 1 1 2 2 2 1 2 2 2 1 3 2 2 1 1 3 1 1 2 1 2 1 3 1 4 1 3 1 1 2 1 2 3 1 1 1 2 2 3 3 1 1 2 4 2 1 2 3 4 3 4 2 5 3 1 2 4 3 4 1 2 3 1 1 3 1 2 2 1 2 3 2 2 2 2 2 2 1 3 2 3 1 5 4 3 4 3 4 3 3 3 4 3 1 4 3 2 2 5 3 2 5 3 2 3 3 2 2 4 3 23 3 3 3 2 7 3 32 92.06' 112.39' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 46 SOUTH ASSEMBLY 46 MIDDLE ASSEMBLY 268 NORTH SOUTH ASSEMBLY 0 1851 E Deere Ave 11/13/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 2.4 ROOF INFORMATION ROOF HEIGHT (FT)30.00 PARAPET HEIGHT (FT) 4.0 ROOF TILT (DEG) 1 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 276 MODULE POWER (W) 535 ARRAY OUTPUT (Kw) 147.66 ARRAY AZIMUTH 220 PART QUANTITIES ITEM QTY Base 648 Module Connector 552 Rail 826 Cam 552 Cam Claw 552 Deflector 276 Base Pad 0 Ballast Block 568 Mechanical Attachment 23 LOADING DETAILS SINGLE MODULE WT (LB) 61.7 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 40105 ARRAY AREA (SQ. FT)9502 ARRAY LOAD (PSF) 4.22 ARRAY CLEARANCES PER ASCE 7 CONDITION 1 (in.) N/A CONDITION 2 (in.) N/A CONDITION 3 (in.) N/A CONDITION 4 (in.) N/A APPROVED FOR CONSTRUCTION SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA BALLAST LAYOUT - 2.4 PC-113 24.09.26.0 v3.0.9405.9.1 CM BALLAST LAYOUT - 2.4 PC-11 3 As - B u i l t AD 20 2 4 - 1 0 - 1 6 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 1/12" = 1'-0" 3 2 1 2 1 2 1 1 1 1 11 2 2 3 2 2 2 2 2 1 2 1 1 2 1 1 3 1 2 2 2 3 1 2 3 2 1 2 2 2 2 12 2 2 1 2 2 2 2 3 3 2 1 2 2 2 2 2 1 2 3 12 2 2 4 4 1 2 1 1 3 3 3 3 4 4 5 2 2 1 1 4 3 3 4 4 6 1 2 12 5 4 3 4 4 4 7 2 2 2 3 3 4 8 4 4 7 2 2 2 4 4 4 7 8 4 3 2 4 7 8 1 2 4 4 7 8 3 1 2 26 4 8 3 1 2 2 2 3 5 6 7 2 3 2 3 1 5 3 4 5 8 1 2 1 5 4 4 2 1 4 6 3 2 1 4 3 5 4 4 1 5 3 5 5 3 4 25 5 4 3 4 25 3 4 4 92.06' 149.87' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 96 SOUTH ASSEMBLY 96 MIDDLE ASSEMBLY 360 NORTH SOUTH ASSEMBLY 0 1851 E Deere Ave 11/13/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 2.6 ROOF INFORMATION ROOF HEIGHT (FT)30.00 PARAPET HEIGHT (FT) 4.0 ROOF TILT (DEG) 1 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 270 MODULE POWER (W) 535 ARRAY OUTPUT (Kw) 144.45 ARRAY AZIMUTH 220 PART QUANTITIES ITEM QTY Base 606 Module Connector 540 Rail 777 Cam 540 Cam Claw 540 Deflector 270 Base Pad 0 Ballast Block 536 Mechanical Attachment 21 LOADING DETAILS SINGLE MODULE WT (LB) 61.7 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 38496 ARRAY AREA (SQ. FT)9305 ARRAY LOAD (PSF) 4.14 ARRAY CLEARANCES PER ASCE 7 CONDITION 1 (in.) N/A CONDITION 2 (in.) N/A CONDITION 3 (in.) N/A CONDITION 4 (in.) N/A APPROVED FOR CONSTRUCTION SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA BALLAST LAYOUT - 2.6 PC-133 24.09.26.0 v3.0.9405.9.1 CM BALLAST LAYOUT - 2.6 PC-13 3 As - B u i l t AD 20 2 4 - 1 0 - 1 6 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 1/12" = 1'-0" 43 4 3 3 4 3 3 4 4 4 3 2 3 4 4 2 2 3 4 4 3 2 2 2 4 5 4 7 1 1 2 2 3 7 7 7 2 1 1 2 2 3 8 1 1 2 1 1 3 1 2 2 3 1 1 1 2 1 1 1 3 1 1 2 3 1 1 2 2 1 5 3 1 2 2 1 3 4 3 1 2 2 1 2 2 5 3 1 2 2 2 5 4 4 2 2 1 2 2 7 4 2 1 2 2 2 7 4 5 2 2 2 2 2 7 4 4 2 2 2 4 2 7 4 4 5 2 2 2 3 2 5 4 4 5 2 2 2 3 3 5 4 5 2 2 2 3 3 5 3 4 5 2 2 2 3 4 3 4 4 2 2 2 4 4 3 3 5 2 2 4 3 4 2 2 4 3 2 2 41 2 1 2 1 2 11 2 2 92.06' 149.87' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 66 SOUTH ASSEMBLY 66 MIDDLE ASSEMBLY 408 NORTH SOUTH ASSEMBLY 0 1851 E Deere Ave 11/13/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 2.5 ROOF INFORMATION ROOF HEIGHT (FT)30.00 PARAPET HEIGHT (FT) 4.0 ROOF TILT (DEG) 1 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 184 MODULE POWER (W) 535 ARRAY OUTPUT (Kw) 98.44 ARRAY AZIMUTH 220 PART QUANTITIES ITEM QTY Base 438 Module Connector 368 Rail 581 Cam 368 Cam Claw 368 Deflector 184 Base Pad 0 Ballast Block 390 Mechanical Attachment 15 LOADING DETAILS SINGLE MODULE WT (LB) 61.7 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 27182 ARRAY AREA (SQ. FT)6333 ARRAY LOAD (PSF) 4.29 ARRAY CLEARANCES PER ASCE 7 CONDITION 1 (in.) N/A CONDITION 2 (in.) N/A CONDITION 3 (in.) N/A CONDITION 4 (in.) N/A APPROVED FOR CONSTRUCTION SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA BALLAST LAYOUT - 2.5 PC-123 24.09.26.0 v3.0.9405.9.1 CM BALLAST LAYOUT - 2.5 PC-12 3 As - B u i l t AD 20 2 4 - 1 0 - 1 6 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 1/12" = 1'-0" 4 2 3 2 3 3 1 5 2 1 2 2 2 4 3 2 3 2 2 2 3 5 4 2 2 2 4 2 2 1 3 3 2 2 2 3 1 3 2 2 1 1 2 2 1 2 3 2 1 2 2 1 2 2 22 2 1 1 2 1 2 2 2 2 1 2 2 1 21 1 1 2 3 3 2 2 1 4 2 4 1 2 3 3 4 2 2 1 2 3 3 3 6 4 2 2 2 1 2 2 1 3 3 5 4 2 2 4 2 3 4 2 4 4 6 2 1 2 3 2 3 2 3 4 7 2 1 2 2 3 2 4 2 4 8 2 2 3 1 1 3 3 3 8 2 2 2 1 2 4 2 2 2 2 2 2 2 2 87.45' 149.87' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 70 SOUTH ASSEMBLY 70 MIDDLE ASSEMBLY 228 NORTH SOUTH ASSEMBLY 0 1851 E Deere Ave 11/13/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: SITE MAP A PC-2NTS RACKING CONSTRUCTION SET SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA PROJECT SUMMARY PC-23 24.09.26.0 v3.0.9405.9.1 CM clawFR 10 Degree - 29 cm PROJECT PART QUANTITY ITEM PART NUMBER QTY Base 500050202 2514 BASE, 02, CFR Module Connector 500050704 2178 MODULE CONNECTOR, 1150, 10D, CFR Rail 2000895 3209 RAIL, 2500, CFR Cam 5000500 2178 CAM, 10D, CFR Cam Claw 2000673 2178 CAM CLAW, CFR Deflector 200088705 1089 DEFLECTOR, 10D, 2300, CFR Bolt 2000697 11319 BLT, HEX FLG, TRI, M6X16, GR8.8, PATCH Base Pad 2000678 0 PAD, BASE, CFR CONCRETE MASONRY UNIT N/A 2074 BLOCK, CONCRETE, 32.6 LB, - Xin x 8in x 16in NOMINAL, PARTNER SUPPLIED, SEE INSTALLATION MANUAL APPROVED FOR CONSTRUCTION MECHANICAL ATTACHMENT PART QUANTITY MA Hardware Kit 5000423 8 HW KIT, MA STRUT, 2500, CFR MA Strut 2000930 80 MA STRUT, 2500, CFR Mechanical Attachment 100035906 80 MA, ANCH 2400, SIKA PVC TOTAL MECHANICAL ATTACHMENT COUNT 80 PROJECT SUMMARY MODULE TYPE ADANI ASB-M10-144-535 MODULE DIMENSIONS (IN.)89.21 X 44.61 X 1.38 NUMBER OF MODULES 1089 MODULE WATTAGE (W STC)535 SYSTEM SIZE (kW STC)582.615 SYSTEM WEIGHT (LB)152604 SYSTEM AREA (SQ FT.)37506 AGGREGATE SYSTEM LOAD (PSF)4.07 NUMBER OF ARRAYS 6 ARRAY TILT (DEG)8.99 3 As - B u i l t AD 20 2 4 - 1 0 - 1 6 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 Roof 1 Roof 2 1851 E Deere Ave 11/13/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: ARRAY SITE MAP A PC- NTS EXISTING ROOF PERIMETER ARRAY # (TYP) ROOF SETBACK (TYP) KEEPOUTS (TYP) # RACKING CONSTRUCTION SET NOTES: 1.ALL DIMENSIONS SHOWN ARE BASED UPON INFORMATION PROVIDED TO PANELCLAW. FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION OF THE SOLAR ARRAY. NOTIFY PANELCLAW OF ANY DISCREPANCIES. APPROVED FOR CONSTRUCTION SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA ARRAY SITE MAP PC-33 24.09.26.0 v3.0.9405.9.1 CM ROOF NAME ROOF SETBACK (FT.) ROOF HEIGHT (FT) PARAPET HEIGHT (FT) ROOF TILT (DEG) Roof 1 4.00 20.00 5.0 1 Roof 2 4.00 30.00 4.0 1 KEEPOUT NAME KEEPOUT CLEARANCE (FT.) KEEPOUT HEIGHT (IN.) Group 1 4 192 Group 2 4 168 Group 2 4 48 Group 3 4 36 Group 3 4 12 Group 4 4 72 3 3 As - B u i l t AD 20 2 4 - 1 0 - 1 6 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 209' 14' 67' 123' 199' 322' 157' 79' 108' 43'8'56' 202' 233' 1 243' 42' 79' 157' 322' 199' 2 3 4 5 6 1851 E Deere Ave 11/13/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.1 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 5.0 ROOF TILT (DEG) 1 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 104 MODULE POWER (W) 535 ARRAY OUTPUT (Kw) 55.64 ARRAY AZIMUTH 220 PART QUANTITIES ITEM QTY Base 254 Module Connector 208 Rail 296 Cam 208 Cam Claw 208 Deflector 104 Base Pad 0 Ballast Block 95 LOADING DETAILS SINGLE MODULE WT (LB) 61.7 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 11151 ARRAY AREA (SQ. FT)3577 ARRAY LOAD (PSF) 3.12 ARRAY CLEARANCES PER ASCE 7 CONDITION 1 (in.) 3 CONDITION 2 (in.) 6 CONDITION 3 (in.) 6 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA BALLAST LAYOUT - 1.1 PC-83 24.09.26.0 v3.0.9405.9.1 CM BALLAST LAYOUT - 1.1 PC-8 3 As - B u i l t AD 20 2 4 - 1 0 - 1 6 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 1/6" = 1'-0" 22 2 2 21 22 2 2 2 2 2 2 22 1 2 1 1 2 1 1 2 2 21 2 11 1 1 1 2 2 1 2 2 2 2 1 2 2 2 2 1 2 1 3 2 2 2 2 2 2 59.81' 104.89' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 44 SOUTH ASSEMBLY 44 MIDDLE ASSEMBLY 118 NORTH SOUTH ASSEMBLY 2 1851 E Deere Ave 11/13/2024 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 2.2 ROOF INFORMATION ROOF HEIGHT (FT)30.00 PARAPET HEIGHT (FT) 4.0 ROOF TILT (DEG) 1 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 75 MODULE POWER (W) 535 ARRAY OUTPUT (Kw) 40.125 ARRAY AZIMUTH 220 PART QUANTITIES ITEM QTY Base 162 Module Connector 150 Rail 210 Cam 150 Cam Claw 150 Deflector 75 Base Pad 0 Ballast Block 163 Mechanical Attachment 7 LOADING DETAILS SINGLE MODULE WT (LB) 61.7 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 11143 ARRAY AREA (SQ. FT)2587 ARRAY LOAD (PSF) 4.31 ARRAY CLEARANCES PER ASCE 7 CONDITION 1 (in.) N/A CONDITION 2 (in.) N/A CONDITION 3 (in.) N/A CONDITION 4 (in.) N/A APPROVED FOR CONSTRUCTION SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA BALLAST LAYOUT - 2.2 PC-93 24.09.26.0 v3.0.9405.9.1 CM BALLAST LAYOUT - 2.2 PC-9 3 As - B u i l t AD 20 2 4 - 1 0 - 1 6 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 1/6" = 1'-0" 5 3 3 1 3 2 5 1 1 2 3 2 4 2 1 1 1 2 3 2 2 1 1 1 3 3 4 2 1 1 1 3 4 2 1 1 2 4 6 2 1 2 1 21 2 2 1 3 2 1 4 2 3 7 2 12 52 84 85 92.06' 37.42' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 10 SOUTH ASSEMBLY 10 MIDDLE ASSEMBLY 128 NORTH SOUTH ASSEMBLY 2 1851 E Deere Ave 11/13/2024 U-ANCHOR 2400 MECHANICAL ATTACHMENT: MANUFACTURED BY OTHERS NOTE: THIS DETAIL IS GENERIC IN NATURE AND IS INTENDED ONLY TO SHOW TYPICAL MECHANICAL ATTACHMENT ASSEMBLY LOCATIONS. REFER TO INDIVIDUAL ARRAY LAYOUTS FOR REQUIRED LOCATIONS. U-ANCHOR 2400 MECHANICAL ATTACHMENT MA STRUT 3/8, 304 S.S.FLAT WASHER 3/8-16, 304 S.S. HARDWARE 1.25" LENGTH BOLT 3/8-16, 304 S.S. HEX FLANGE NUT M6, HARDWARE 16MM LENGTH BOLT STRUT BRACKET U-BRACKET MECHANICAL ATTACHMENT SOUTH EDGE APPLICATION CENTERED BELOW MODULES MECHANICAL ATTACHMENT SOUTH EDGE APPLICATION CENTERED BETWEEN MODULES MECHANICAL ATTACHMENT INTERIOR APPLICATION CENTERED BETWEEN MODULES MECHANICAL ATTACHMENT NORTH EDGE APPLICATION CENTERED BETWEEN MODULES MECHANICAL ATTACHMENT NORTH EDGE APPLICATION CENTERED BELOW MODULES TRANSPARENT PV SOLAR MODULE MECHANICAL ATTACHMENT INTERIOR APPLICATION CENTERED BELOW MODULES MA STRUT ø 6.4 mm (0.25 in) RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: MECHANICAL ATTACHMENT DETAIL B N.T.S.SCALE: MECHANICAL ATTACHMENT DETAIL C N.T.S. SCALE: MECHANICAL ATTACHMENTLOCATION DETAIL A N.T.S. MECHANICAL ATTACHMENT WORST-CASE SERVICE LOAD (LB) 1.HORIZONTAL LOAD H MAY ACT IN ANY DIRECTION 2.WORKING LOADS = ALLOWABLE LOADS (i.e. NON-FACTORED) HORIZONTAL (H)VERTICAL (V) WIND SEISMIC WIND MAXIMUM ALLOWABLE LOAD (LB) HORIZONTAL (H)VERTICAL (V) RACKING CONSTRUCTION SET SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA 3 PC-14 MECHANICAL ATTACHMENT DETAIL 24.09.26.0 v3.0.9405.9.1 CM 3 As - B u i l t AD 20 2 4 - 1 0 - 1 6 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 0 624 462 650 525 APPROVED FOR CONSTRUCTION PC-14 PC-14 PC-14 1851 E Deere Ave 11/13/2024 539 ' - 6 " 46'-7" 184 ' - 0 " 628 ' - 6 " 368'-6 " ACD MDP UM SLC 39'-10" 283 ' - 5 " 301 ' - 4 " 426 ' - 4 " 98' - 9 " INV INV INV INV INV GEN MSB T T T T INV INV INV INV INV T MS B T T T GEN MDP UM ACD SLC INV INV INV INV INV INV INV INV SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-1 DATE: 07/03/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 05/31/2024 F REVISION 06/20/2024 G REVISION 06/20/2024 H REVISION 06/26/2024 I REVISION 07/03/2024 J REVISION 09/05/2024 K REVISION 09/27/2024 L PLOT PLAN WITH ROOF PLAN PV-1 1 SCALE: 3/128"=1'-0" SITE PLAN ROOF #1 (985) ADANI SOLAR ASB-M10-535 (535W) MODULES (E) DRIVEWAY TREES PROP E R T Y L I N E PRO P E R T Y L I N E PRO P E R T Y L I N E PR O P E R T Y L I N E ROOF #2 (104) ADANI SOLAR ASB-M10-535 (535W) MODULES (E) FENCE ELECTRICAL ROOM (N) RACK (TYP.) SITE NOTES · A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. · THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM . · THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. · PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [CEC 2022] ELECTRICAL ROOM 2 (N) 3 x SUNNY TRIPOWER CORE1 62-US [480V] INVERTERS (N) 6 x SUNNY TRIPOWER CORE1 62-US [480V] INVERTERS (E) TRANSFORMER (E) TRANSFORMER (E) MAIN SWITCHBOARD (E) GENERATOR PULLM A N S T E D E E R E A V E (E) UTILITY METER (E) MAIN DISTRIBUTION PANEL (N) SERVICE DISCONNECT (N) SOLAR LOAD CENTER 1851 E Deere Ave 11/13/2024 48" FIRE SETBACK 48" FIRE SETBACK 48 " F I R E S E T B A C K 48 " F I R E S E T B A C K 52 ' - 5 " 40 ' - 3 " 90 ' - 7 " 7' - 2 " ACD MDP UM SLC 48" FIRE SETBACK 48" FIRE SETBACK 48" FIRE SETBACK 48 " F I R E S E T B A C K 48 " F I R E S E T B A C K 5' - 6 " 48" FIRE SETBACK 48" FIRE SETBACK48" FIRE SETBACK 48 " F I R E S E T B A C K 48 " F I R E S E T B A C K 48 " F I R E S E T B A C K INV INV INV INV INV 7'-5"59'-7"22'-5"5'-7" 36" FIRE SETBACK 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K 15 ' - 5 " 58 ' - 7 " 4' - 9 " 20'-11"89'-5"7'-6" 14'-11" 4'-5" GEN MS B T T T T 7'-5" 74'-6" 8' - 1 1 " 31 ' - 1 " 23 ' - 4 " 40 ' - 3 " 5' - 6 " 44 ' - 1 0 " 7' - 7 " 67'-1"12'-9"149'-1" INV INV INV INV MDP UM ACD SLC SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-2 DATE: 07/03/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 05/31/2024 F REVISION 06/20/2024 G REVISION 06/20/2024 H REVISION 06/26/2024 I REVISION 07/03/2024 J REVISION 09/05/2024 K REVISION 09/27/2024 L 1 ROOF PLAN & MODULES PV-2 SCALE: 1/32" = 1'-0" ADANI SOLAR ASB-M10-535 (535W) MODULES 89 . 2 1 " 44.61" DESIGN SPECIFICATION RISK CATEGORY:II CONSTRUCTION:COMMERCIAL ZONING:COMMERCIAL SNOW LOAD (ASCE 7-16):0 PSF EXPOSURE CATEGORY:C WIND SPEED (ASCE 7-16):95 MPH MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES:1089 MODULES MODULE TYPE:ADANI SOLAR ASB-M10-535 (535W) MODULES MODULE WEIGHT:61.73 LBS MODULE DIMENSIONS:89.21" X 44.61" = 27.64 SF UNIT WEIGHT OF AREA:2.23 PSF ROOF PLAN & MODULES ROOF DESCRIPTION ROOF ROOF TILT AZIMUTH ROOF MATERIAL #1 0°220°PVC/TPO #2 0°220°PVC/TPO ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 985 27215.55 60885.52 45 #2 104 2873.52 9778.34 29 LEGEND MDP - VENT, ATTIC FAN (ROOF OBSTRUCTION) - MAIN DISTRIBUTION PANEL UM - UTILITY METER ACD - SERVICE DISCONNECT 72" FIRE SETBACK (N) BALLAST BLOCK (N) RAIL ROOFS #1 & #2 (1089) ADANI SOLAR ASB-M10-535 (535W) MODULES (E ) FR O N T O F B U I L D I N G PU L L M A N S T (E ) BA C K O F B U I L D I N G - BALLAST BLOCK - RAIL (N) 9 x SUNNY TRIPOWER CORE1 62-US [480V] INVERTERS (ON ROOF) - SUNNY TRIPOWER CORE1 62-US [480V] (N) PANELCLAW CLAW FR 10 DEGREE RACKING SYSTEM (N) EMT CONDUIT 48" FIRE SETBACK SLC - SOLAR LOAD CENTER (E) UTILITY METER (E) MAIN DISTRIBUTION PANEL (N) SERVICE DISCONNECT (N) SOLAR LOAD CENTER (N) RACK (TYP.) ARRAYS #1 TO #5 ARRAY TILT - 10° AZIM. - 220° 36" FIRE SETBACK ELECTRICAL ROOM ELECTRICAL ROOM 2 INV (E) TRANSFORMER (E) GENERATOR (E) 3 x TRANSFORMERS (E) MAIN SWITCHBOARD - TRANSFORMERT - GENERATORGEN MSB - MAIN SWITCHBOARD - MECHANICAL ATTACHMENT (N) MECHANICAL ATTACHMENT E DEERE AVE 1851 E Deere Ave 11/13/2024 CAM SPACING BASE HOLE "2" BASE HOLE "1" BASE HOLE "1" BASE HOLE "2" BASE HOLE "3" BASE HOLE "3" BASE HOLE "1"BASE HOLE "3"BASE HOLE "1"BASE HOLE "3"BASE HOLE "3"BASE HOLE "1"BASE HOLE "3"BASE HOLE "2" ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: CAM SPACING DETAIL A NTS SCALE: NORTH ASSEMBLY B NTS SCALE: SOUTH ASSEMBLY D NTS SCALE: MIDDLE ASSEMBLY C NTS SCALE: NORTH SOUTH ASSEMBLY E NTS SCALE: EXAMPLE ARRAY CONSTRUCTION F NTS RACKING CONSTRUCTION SET SolarCo Energy Inc. Medtronic 1851 E Deere Ave, Santa Ana, CA 92705, USA ASSEMBLIES PC-53 24.09.26.0 v3.0.9405.9.1 CM APPROVED FOR CONSTRUCTION 3 As - B u i l t AD 20 2 4 - 1 0 - 1 6 2 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 3 - 2 0 1 Up d a t e d A d d r e s s DH 20 2 4 - 0 2 - 2 9 0 In i t i a l B a l l a s t M a p L a y o u t GZ 20 2 4 - 0 1 - 1 2 PC-5 PC-5 PC-5 PC-5 PC-5 PC-5 STANDARD ASSEMBLY QUANTITY NORTH ASSEMBLY 332 SOUTH ASSEMBLY 332 MIDDLE ASSEMBLY 1510 NORTH SOUTH ASSEMBLY 4 NOTE: ASSEMBLIES IN THIS TABLE USE THE STANDARD 2-PAD BASE CAM SPACING mm 59UNITS inches 2 5/16 1851 E Deere Ave 11/13/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-11 DATE: 07/03/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 04/09/2024 D REVISION 05/29/2024 E REVISION 05/31/2024 F REVISION 06/20/2024 G REVISION 06/20/2024 H REVISION 06/26/2024 I REVISION 07/03/2024 J FAULT CURRENT CALCULATIONS 1851 E Deere Ave 11/13/2024 ACD MDP UM SLC INV INV INV INV INV 18 1 18 1 17 1 17 17 1 17 1 17 1 1 17 1 17 1 1 16 1 1 1 1 16 1 16 1 15 1 15 1 16 1 16 1 15 1 15 1 15 1 15 1 15 15 17 1 17 1 17 1 1 GEN MS B T T T T 17 16 1 1 17 1 17 1 17 17 17 117 1 1 1 1 1 17 17 17 17 16 1 18 INV INV 18 1 1 17 1 17 1 17 11 17 17 111 1 1 1817 18 17 1616 1 16 1 16 1 16 16 16 1 1 15 1 11 16 16 16 1 1 16 1 1 16 16 1 1 1 17 16 17 1 INV INV SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-2A DATE: 07/03/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 05/31/2024 F REVISION 06/20/2024 G REVISION 06/20/2024 H REVISION 06/26/2024 I REVISION 07/03/2024 J REVISION 09/05/2024 K REVISION 09/27/2024 L 1 STRING LAYOUT & BOM PV-2A SCALE: 1/32" = 1'-0" STRING LAYOUT & BOM BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 1089 ADANI SOLAR ASB-M10-535 (535W) MODULES INVERTER 9 SUNNY TRIPOWER CORE1 62-US [480V] INVERTERS SOLAR LOAD CENTER 1 SOLAR LOAD CENTER 1000A RATED, 480V, 3PH, 4W MONITORING SYSTEM 1 ALSO ENERGY DATA AGGREGATION SYSTEM SERVICE DISCONNECT 1 1000A FUSED SERVICE DISCONNECT WITH (3) 900A FUSES, 480V, 3PH, 4W, NEMA 3R UL LISTED PU L L M A N S T (E ) F R O N T O F B U I L D I N G (E ) B A C K O F B U I L D I N G INVERTER #1 02 x STRINGS OF 18 MODULES 06 x STRINGS OF 17 MODULES = 138 MODULES STRING INFORMATION INVERTER #2 02 x STRINGS OF 18 MODULES 06 x STRINGS OF 17 MODULES = 138 MODULES INVERTER #3 01 x STRING OF 16 MODULES 07 x STRINGS OF 17 MODULES = 135 MODULES INVERTER #4 01 x STRING OF 16 MODULES 07 x STRINGS OF 17 MODULES = 135 MODULES INVERTER #5 08 x STRINGS OF 16 MODULES = 128 MODULES INVERTER #6 01 x STRING OF 15 MODULES 07 x STRINGS OF 16 MODULES = 127 MODULES INVERTER #7 02 x STRINGS OF 16 MODULES 04 x STRINGS OF 15 MODULES = 92 MODULES INVERTER #8 02 x STRINGS OF 16 MODULES 04 x STRINGS OF 15 MODULES = 92 MODULES INVERTER #9 02 x STRINGS OF 18 MODULES 04 x STRINGS OF 17 MODULES = 104 MODULES E DEERE AVE 1851 E Deere Ave 11/13/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-3B DATE: 07/03/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 05/31/2024 F REVISION 06/20/2024 G REVISION 06/20/2024 H REVISION 06/26/2024 I REVISION 07/03/2024 J REVISION 09/05/2024 K REVISION 09/27/2024 L TAP DETAIL 1851 E Deere Ave 11/13/2024 1 20A 3P HP-1 600A BUS 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 2 15A 3P HP-3 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 3 HP-4 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 4 HP-5 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 5 HP-6 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 6 HP-7 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 7 20A 3P HP-8 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 8 HP-9 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 9 HP-10 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 10 HP-11 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 11 HP-12 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 12 HP-13 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 13 HP-14 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 14 HP-15 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 15 HP-16 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 16 30A 3P HP-17 3/ 4 " C - 3 # 8 & 1 # 1 0 G N D 17 HP-18 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 18 HP-19 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 19 HP-20 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 20 20A 3P HP-21 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 21 HP-22 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 22 HP-23 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 23 HP-24 3/ 4 " C - 3 # 8 & 1 # 1 0 G N D 24 20A 3P HP-25 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 25 25A 3P HP-26 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 26 45A 3P HP-27 3/ 4 " C - 3 # 6 & 1 # 1 0 G N D 27 30A 3P HP-28 3/ 4 " C - 3 # 8 & 1 # 1 0 G N D 28 15A 3P EF-5 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 29 EF-6 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 30 EF-7 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 31 EF-8 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 32 EF-12 3/ 4 " C - 3 # 1 0 & 1 # 1 0 G N D 33 30A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 15A 3P 30A 3P 15A 3P 15A 3P 15A 3P 15A 3P 3 HMC1-1 480V, 3PH, 3W 11 1" C - 1 #3/0 G 11 1" C - 1 #3/0 G G 20 CLD1-1 200A 3P 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D 7 CLP1-1 500A 3P 600A BUS 208/120V, 3PH, 4W 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D 7 CLP1-2 200A 3P 200A 3P 200A 3P SPARE SPARE (2)3" C - (8)#250KCMIL & (2)#2 GND 1"C - 1#1/0G1- 1 / 4 " C - ( 4 ) # 6 A W G & 1 # 1 0 G N D 19 EHP1-1 CLP1-1, 32-34 14 50A 3P 225A 3P 225A 3P 50A 3P 400A 3P 175A 3P 225A 3P 500A 3P1600A 3PG 480/277V, 3PH, 3W PULL SECTION MAIN AND METER SECTION DISTRIBUTION SECTION 1-1/4" C - (4)#6 AWG & 1 #10 GND 1600A BUS MAX AVAILABLE FAULT CURRENT: 32KA SHORT CIRCUIT WITHSTAND RATING: 42KA (2)2-1/2" C - (6)#250KCMIL & 2 #1 GND (2)4" C.O.(2)5" C.O. 2" C - (3)#4/0 & 1 #2 GND "ATS-2" 260A/3P 480V 3PH, 3W 17 15 15 1 MSB-1-1 2" C - ( 3 ) # 4 / 0 & 1 # 2 G N D 1- 1 / 4 " C - ( 4 ) # 6 A W G & 1 # 1 0 G N D SOUTHERN CALIFORNIA EDISON TRANSFORMER AND FUSE SWITCH TO SOUTHERN CALIFORNIA EDISON POLE "ATS-1" 260A/4P 480/277V 3PH, 4W 16 EGRESS LTG PULLMAN CRITICAL LOADS 2" C - ( 3 ) # 4 / 0 & 1 # 2 G N D 19 HP1-1 LTGLCP1LCP2 2- 1 / 2 " C - ( 4 ) # 4 / 0 & 1 # 2 G N D "T1D" 150KVA 480-208/120V 3PH, 4W 18 3/4"C - 1#6G "T1B" 45KVA 208/120V 3PH, 4W 5 1- 1 / 4 " C - ( 3 ) # 4 A W G & 1 # 8 G N D 2" C - ( 4 ) # 1 / 0 A W G & 1 # 2 G N D LP1-5LP1-6 150A 3P MCB 8 (1)1-1/4"C W/ (4)#2AWG & 1 #8 GND 1"C - 1#1/0G "T1A" 112.5KVA 480-208/120V 3PH, 4W 4 2" C - ( 3 ) # 2 / 0 A W G & ( 1 ) # 6 G N D 3- 1 / 2 " C - ( 4 ) 5 0 0 K C M I L & ( 1 ) # 2 G N D 200A 3P 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D 7 LP1-1 400A BUS 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D 7 LP1-2 200A 3P PULLMAN HOUSE/OFFICE LOADS 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D 7 LP1-3 200A 3P 200A 3P SPARE 400A 3P 208/120V, 3PH, 4W (4) 225A BUSSES SPACE 2 LD1-1 12 LD1-2 200A 3P 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D 9 LP1-8 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D LP1-9 200A 3P PULLMAN LAB LOADS 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D LP1-10 200A 3P 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D LP1-11 200A 3P 2- 1 / 2 " C - 4 # 3 / 0 & 1 # 6 G N D LP1-12 200A 3P 9 9 9 9 200A 3P 200A 3P SPARE SPARE 225A 3P SPARE 800A BUS (4) 225A BUSSES SPACE 208/120V, 3PH, 4W 1"C - 1#3/0G "T1A" 225KVA 480-208/120V 3PH, 4W 10 (2 ) 2 " C - ( 6 ) # 3 / 0 A W G & ( 2 ) # 2 G N D (3 ) 4 " C - ( 1 2 ) 3 5 0 K C M I L & ( 3 ) # 1 / 0 G N D 800A 3P LINK BUILDING LOADS "GENERATOR" 150KW/187.5KVA 480/277V 3PH, 3W 13 M POINT OF INTERCONNECTION SUPPLY SIDE TAP CONTINUED FROM SHEET NO. PV-4A FAULT CURRENT: AT MAIN DISTRIBUTION PANEL (SERVICE ENTRANCE) SYSTEM: THREE PHASE FAULT CURRENT: 14971A SHORT CIRCUIT VALUE: 14.971 KAIC LENGTH: 60FT VOLTAGE: 480V SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-4 DATE: 07/03/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , C A 9 2 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 04/09/2024 D REVISION 05/29/2024 E REVISION 05/31/2024 F REVISION 06/20/2024 G REVISION 06/20/2024 H REVISION 06/26/2024 I REVISION 07/03/2024 J ELECTRICAL LINE DIAGRAM PV-4 ELECTRICAL LINE DIAGRAM SCALE: NTS 1 NORTH 1600A MAIN CIRCUIT BREAKER RATING: SERVICE INFO MAIN SERVICE VOLTAGE: MAIN SERVICE PANEL: MAIN SERVICE LOCATION: 480V 1600A 07/09/2024 VSE Project Number: U6505.0002.241 ELECTRICAL ONLY 651 W. galena park blvd. ste. 101 draper, Utah 84020 phone (801) 990-1775 www.vectorse.com ® The contractor must notify Vector Structural Engineering, LLC, should discrepancies between the as-built electrical system and what is shown on the permit plans be found. Vector Structural Engineering shall be notified of any changes from the approved design before installation. Vector Structural Engineering assumes no responsibility for improper installation of the solar system. 1851 E Deere Ave 11/13/2024 21 3 21 3 52131516 21 3 (128) ADANI SOLAR ASB-M10-535 (535W) MODULES 8 x STRINGS OF 16 MODULES INVERTER #5 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 21 3 21 3 6213 21 3 15 16 15 16 15 16 15 16 15 16 15 16 15 16 100A/3P 20A/3P (N) SOLAR LOAD CENTER, 1000A, 480V, 3-PH, 4-W 100A/3P 100A/3P 100A/3P 100A/3P 100A/3P 100A/3P 100A/3P 100A/3P 21 3 21 3 12131718 21 3 17 18 16 17 16 17 (138) ADANI SOLAR ASB-M10-535 (535W) MODULES 2 x STRINGS OF 18 MODULES 6 x STRINGS OF 17 MODULES INVERTER #1 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 21 3 21 3 2213 21 3 16 17 16 17 16 17 16 17 { INVERTER #2 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 21 3 21 3 32131617 21 3 16 17 16 17 (135) ADANI SOLAR ASB-M10-535 (535W) MODULES 1 x STRING OF 16 MODULES 7 x STRINGS OF 17 MODULES INVERTER #3 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 21 3 21 3 4213 21 3 16 17 15 16 16 17 16 17 16 17 { INVERTER #4 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 2 13 2 13 7 2 131516 2 13 INVERTER #6 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 2 13 2 13 8 2 13 2 13 1516 1516 1516 1516 1516 1516 1415 (127) ADANI SOLAR ASB-M10-535 (535W) MODULES 1 x STRING OF 15 MODULES 7 x STRINGS OF 16 MODULES 2 13 2 13 9 2 131516 1516 1415 2 13 2 13 10 2 131415 1415 1415 INVERTER #9 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 2 13 2 13 11 2 131718 1617 2 13 2 13 12 2 13 INVERTER #7 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 1718 1617 1617 1617 } INVERTER #8 SMA SUNNY TRIPOWER CORE1 62-US OUTPUT: 480 VAC, 79.5A 98.0% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT (104) ADANI SOLAR ASB-M10-535 (535W) MODULES 2 x STRINGS OF 18 MODULES 4 x STRINGS OF 17 MODULES (92) ADANI SOLAR ASB-M10-535 (535W) MODULES 2 x STRINGS OF 16 MODULES 4 x STRINGS OF 15 MODULES (N) ALSO ENERGY MONITORING SYSTEM VREF/PWR CT I/O (N) SERVICE DISCONNECT FOR PV SYSTEM: 480V, 1000A FUSED, NEMA 3R, UL LISTED (3 ) 9 0 0 A F U S E S CONTINUE TO SHEET NO. PV-4A 14 15 13 13 13 13 13 13 INVERTER #2 HAVE SAME MODULE COUNT AS INVERTER #1, INVERTER #4 HAVE SAME MODULE COUNT AS INVERTER #3, INVERTER #8 HAVE SAME MODULE COUNT AS INVERTER #7 }{ N-G BOND GROUND ELECTRODE CONDUCTOR NOTE: THE AC DISCONNECT IS SUITABLE FOR THE USE AS SERVICE EQUIPMENT (SUSE) CEC 230.82(6). MINIMUM 2/0 AWG FAULT CURRENT: AT SOLAR LOAD CENTER SYSTEM: THREE PHASE FAULT CURRENT: 14729A SHORT CIRCUIT VALUE: 14.729 KAIC LENGTH: 10FT VOLTAGE: 480V FAULT CURRENT: AT SERVICE DISCONNECT SYSTEM: THREE PHASE FAULT CURRENT: 14449A SHORT CIRCUIT VALUE: 14.449 KAIC LENGTH: 10FT VOLTAGE: 480V FAULT CURRENT: AT NEAREST INVERTER SYSTEM: THREE PHASE FAULT CURRENT: 7162A SHORT CIRCUIT VALUE: 7.162 KAIC LENGTH: 145FT VOLTAGE: 480V MINIMUM 2/0 AWG SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-4A DATE: 07/03/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 05/31/2024 F REVISION 06/20/2024 G REVISION 06/20/2024 H REVISION 06/26/2024 I REVISION 07/03/2024 J REVISION 09/05/2024 K REVISION 09/27/2024 L ELECTRICAL LINE DIAGRAM PV-4A ELECTRICAL LINE DIAGRAM SCALE: NTS 1 NORTH 1600A MAIN CIRCUIT BREAKER RATING: SERVICE INFO MAIN SERVICE VOLTAGE: MAIN SERVICE PANEL: MAIN SERVICE LOCATION: 480V 1600A NOTE: INVERTERS #1, #2, #3, #4, #5, #6, #7, #8 & #9 HAVE SAME WIRE CALCULATIONS. UTILITY PROVIDER:SOUTHERN CALIFORNIA EDISON NOTE: TAG NO 14 & 15 HAVE FOUR PARALLEL SET OF 2.5" DIA AND 2.0" DIA CONDUIT AND EACH CONDUIT HAVE 4 CABLES (L1, L2, L3 ) 1851 E Deere Ave 11/13/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-4B DATE: 07/03/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 05/31/2024 F REVISION 06/20/2024 G REVISION 06/20/2024 H REVISION 06/26/2024 I REVISION 07/03/2024 J REVISION 09/05/2024 K REVISION 09/27/2024 L ELECTRICAL CALCULATIONS PV-4B ELECTRICAL CALCULATION SCALE: NTS 1 ID TYPICAL INITIAL CONDUCTOR LOCATION FINAL CONDUCTOR LOCATION CONDUCTOR CONDUIT PARALLEL CONDUCTORS CURRENT-CARRYING CONDUCTORS IN CONDUIT CONDUIT FILL PERCENT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT BASE AMP.DERATED AMP. TERM. TEMP. RATING LENGTH VOLTAGE DROP 1 4 ARRAY INVERTER #1 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 121FT 0.51% 2 4 ARRAY INVERTER #1 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 113FT 0.51% 3 4 ARRAY INVERTER #3 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 113FT 0.51% 4 4 ARRAY INVERTER #3 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 113FT 0.51% 5 4 ARRAY INVERTER #5 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 97FT 0.46% 6 4 ARRAY INVERTER #5 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 97FT 0.46% 7 4 ARRAY INVERTER #6 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 97FT 0.46% 8 4 ARRAY INVERTER #6 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 97FT 0.46% 9 3 ARRAY INVERTER #7 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 97FT 0.46% 10 3 ARRAY INVERTER #7 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 89FT 0.25% 11 3 ARRAY INVERTER #9 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 121FT 0.51% 12 3 ARRAY INVERTER #9 10 AWG PV WIRE COPPER OPEN AIR 1 2 N/A N/A 6 AWG THWN-2, COPPER 0.76 (53°C)1 13.63A 17.03A N/A N/A 90°C 113FT 0.51% 13 1 INVERTER #1 TO #9 SOLAR LOAD CENTER 1 AWG THWN-2 COPPER MIN 1.25" Dia EMT 1 3 33.68%100A 8 AWG THWN-2, COPPER 0.76 (53°C)0.1 79.50A 99.37A 145A 110.2A 90°C 230FT 1.17% 14 1 SOLAR LOAD CENTER SERVICE DISCONNECT 250 KCMIL THWN-2 COPPER MIN 2.5" Dia EMT 4 3 27.10%900A 2/0 AWG THWN-2, COPPER 0.94 (31°C)0.1 715.50A 894.37A 4 x 255A 4 x 239.7A 75°C 10FT 0.03% 15 1 SERVICE DISCONNECT MAIN DISTRIBUTION PANEL 250 KCMIL THWN-2 COPPER MIN 2.5" Dia EMT 4 4 27.10%N/A N/A THWN-2, COPPER 0.94 (31°C)0.1 715.50A 894.37A 4 x 255A 4 x 239.7A 75°C 5FT 0.03% NOTE: TAG NO 14 & 15 HAVE FOUR PARALLEL SET OF 2.5" DIA AND 2.0" DIA CONDUIT AND EACH CONDUIT HAVE 4 CABLES (L1, L2, L3 ) NOTE: INVERTERS #1, #2, #3, #4, #5, #6, #7, #8 & #9 HAVE SAME WIRE CALCULATIONS. NOTE: THERE WILL BE A SEPARATE GEC ROUTED FOR SERVICE DISCONNECT. NORTH 1600A MAIN CIRCUIT BREAKER RATING: SERVICE INFO MAIN SERVICE VOLTAGE: MAIN SERVICE PANEL: MAIN SERVICE LOCATION: 480V 1600A UTILITY PROVIDER:SOUTHERN CALIFORNIA EDISON NOTE: ALL DC WIRES ARE TO BE RATED 1000V MINIMUM. 1851 E Deere Ave 11/13/2024 SHEET NAME SHEET SIZE SHEET NUMBER ARCH FULL 24" X 36" Signature with Seal PROJECT NAME & ADDRESS PV-5 DATE: 07/03/2024 REVDATEDESCRIPTION REVISIONS BLEED D 18 5 1 E D E E R E A V E SA N T A A N A , CA 92 7 0 5 ME D T R O N I C , I N C CO M M E R C I A L SolarCo Energy Inc. 22982 La Cadena Dr #219, Laguna Hills, CA 92653 Lic#: 1001001 PH. NO.: (949) 482 2232 permits@SolarCoEnergy.com REVISION 05/31/2024 F REVISION 06/20/2024 G REVISION 06/20/2024 H REVISION 06/26/2024 I REVISION 07/03/2024 J REVISION 09/05/2024 K REVISION 09/27/2024 L PLACARDS LABEL LOCATION: MAIN SERVICE PANEL & UTILITY METER& SUB PANEL, AC PANEL, AC DISCONNECT PLACARDS NOTES 1.CEC ARTICLES 690 AND 705 AND CEC SECTION R331 MARKINGS SHOW HEREON 2.ALL MARKINGS SHALL CONSIST OF THE FOLLOWING: A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING B.RED BACKGROUND COLOR WITH WHITE TEXT AND LINE WORK C.ARIAL FONT. 3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. 4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT USING POP-RIVETS OR SCREWS. 5.THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. 6.WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [CEC 110.21(8) FIELD MARKING]. 7.ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [CFC 605.11.1.3] CODE : PER CEC 690.54 PANEL BOARD ENERGIES FROM TWO SOURCES OF AC POWER SOLAR 715.5A AT 480V & UTILITY GRID 1600A AT 480V 1 Junction Box Scale: NTS 2 Solar Load Center Scale: NTS DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT 3 AC Disconnects Scale: NTS WARNING 4 Scale: NTS CAUTION POWER TO THIS SERVICE IS ALSO SUPPLIED FROM ON-SITE SOLAR/WIND GENERATION AC SYSTEM DISCONNECT CAUTION ALTERNATE POWER SUPPLY AC SYSTEM DISCONNECT WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CODE : PER CEC 110.27(C) & OSHA 1910.145(f)(7) !WARNING ELECTRICAL SHOCK HAZARD CODE : PER CEC 110.27(C) & OSHA 1910.145(f)(7) ! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CODE : PER CEC 690.13(B) ! WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! CODE : PER CEC 706.15(C)(4) and CEC 690.13(B) WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVER CURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR CODE : PER CEC 690.13(B) !WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! CODE : PER CEC 706.15(C)(4) and CEC 690.13(B) WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM! CODE : PER CEC 690.59 and CEC 705.12(D)(3) ! POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. CODE : PER CEC 705.12(B)(3)(2) WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CODE : PER CEC 110.27(C) and OSHA 1910.145(f)(7) !WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! CODE : PER CEC 706.15(C)(4) and CEC 690.13(B) WARNING SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTI WIRE BRANCH CIRCUITS ! CODE : PER CEC 706.15(C)(4) and CEC 690.13(B) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT CODE : PER CEC 690.13(B) RAPID SHUTDOWN FOR SOLAR PV SYSTEM CODE : PER CEC 690.56(C)(2) DO NOT DISCONNECT UNDER LOAD CODE : PER CEC 690.15(B) and CEC 690.33(D)(2) LABEL LOCATION: AC DISCONNECT (UTILITY REQUIREMENT) LABEL LOCATION: AC DISCONNECT (UTILITY REQUIREMENT) 5 Conduit Scale: NTS ! WARNING RACEWAY IS ENERGIZED WHENIN THE OPEN POSITION. DO NOT RELOCATE OR CUT ! WARNING FOR LINE-SIDE TAP: "THE SUM OF THE AMPERE RATINGS OF ALL OVER CURRENT DEVICES ON PANEL BOARDS, BOTH LOAD AND SUPPLY DEVICES, EXCLUDING THE RATING OF THE OVER CURRENT DEVICE PROTECTING THE BUS BAR, SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. PERMANENT WARNING LABELS SHALL BE APPLIED TO DISTRIBUTION EQUIPMENT." THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVER CURRENT DEVICES, EXCLUDING MAIN SUPPLY OVER CURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. LABEL PER CEC 690.56(C)- PROVIDE AT AC DISCONCECT FOR RAPID SHUTDOWN COMPLIANT SYSTEM SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS PER CODE: CEC 690.54 PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT 715.5 AMPS NOMINAL OPERATING AC VOLTAGE 480 VOLTS Main Service Panel POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN. CAUTION! (N) SERVICE DISCONNECT ELECTRICAL ROOM (E) MAIN SWITCHBOARD (E) UTILITY METER (N) SOLAR LOAD CENTER (N) RAKE (TYP.) (N) PV MODULE (N) 9 x SUNNY TRIPOWER CORE1 62-US INVERTERS (ON ROOF) SLC MSBUM ACD GEN MS B T T T T (E) TRANSFORMER (E) MAIN SWITCHBOARD (E) 3 x TRANSFORMERS (E) GENERATOR PU L L M A N S T ELECTRICAL ROOM 2 E DEERE AVE INV INV INV INV INV INV INV INV INV 1851 E Deere Ave 11/13/2024 SolarCo Energy Inc. 08/01/2024 Medtronic, Inc (REVJ) 1851 E Deere Ave, Santa Ana, CA 92705, USA Plan revisions done after REV C (Approved Plans) noted below. 1.The POI location has been changed from the pull section to between the Meter and Main Board. The change can be seen in the ELD page (PV-4). (The page numbering changed a bit, PV-4 in Rev C is now PV-4A in REV J and PV-4A in REV C is now PV-4 in REV J. 2.The neutral line from the inverter has been removed, it was optional. The wire schedule has been updated as well. Changes can be seen in PV-4A and PV-4B. 3.A page has been inserted, PV-3B. That page has the tap details. 4.The Production meter has been removed. Change can be seen in PV-4A and PV-4B. 5.The location of the ACD has Solar Load Center has been changed. 6. The Fault Current Calculations have been added to the plans, see PV-11. 1851 E Deere Ave 11/13/2024 Partner Name:SolarCo Energy Inc. Project Name:Medtronic Project Location:1851 E Deere Ave, Santa Ana, CA 92705, USA Racking System:clawFR 10 Degree Structural Calculations for Roof-Mounted Solar Array Submittal Release: Rev 3 Engineering Seal 10/16/2024 APPROVED FOR CONSTRUCTION 1851 E Deere Ave 11/13/2024 5.0 Design Loads - Wind (Cont.): 5.1.2 Global Wind Shear Summary Table: Mechanical attachments may be required for several reasons including building code, roof load limits and array shape. The table below provides the mechanical attachment requirements for each sub-array within this project.  Applied Load Resisting Load Code Check Sub- Array Name FL-D = Wind Uplift (lbs.) FD = Wind Drag (lbs.) DL = Total Dead Load (lbs.) Maximum Allowable Mechanical Attachment Strength (lbs.) Total MA Capacity (lbs.) Check Calculated Factor of Safety* Check 1.1 5,153 1,908 11,151 650 0 2.37 OK 2.2 5,210 1,809 11,143 650 4,550 3.37 OK 2.3 9,412 3,620 24,526 650 9,100 3.86 OK 2.4 16,326 4,730 40,105 650 14,950 3.99 OK 2.5 9,381 3,840 27,182 650 9,750 4.16 OK 2.6 15,651 4,504 38,496 650 13,650 3.95 OK Total:61,133 lbs.20,411 lbs.152,604  52,000 lbs. Table 5.2 Summary of Mechanical Attachment Requirements * Back calculated factor of safety provided to determine factor of safety applied to dead load in lieu of 0.6 in ASCE 7-16 equation 7, BACK CALCULATED FACTOR OF SAFETY = (DEAD LOAD+MECHANICAL ATTACHMENT)/(((.6)WIND SHEAR/FRICTION)+(.6)WIND UPLIFT) 10/16/2024 APPROVED FOR CONSTRUCTION 10 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 6.0 Design Loads - Downward: 6.1 Downward Wind Load Calculation: WLin = qz * Am * GCP * cos θ Where: qz =19.25 psf (Ref. Section 3.1, Wind Load Data) Am =27.64 sq.ft.(Single Module Area)(Ref. Section 1.1, General Project Information) θ =8.99 deg.(Ref. Section 1.1, General Project Information) GCP =1.13 (Inward)(Proprietary Wind Tunnel Data) GCP =0.30 (Inward with snow)(ASCE, Fig. 30.3-5A) WLin(no snow) = 594 lbs./module WLin(with snow) = 158 lbs./module Contact Base by Location:                                                        Contact Pad by Information: 1 =South Distance Between C.C. outer Pads =12.5 in. 2 =Interior Typical Pad Area =9 sq.in. 3 =2nd from North 4 =North 6.2 Racking Dimensions for Point Loads: Inter-Module Support spacing (S) = 48.62 in. Inter-Column Support Spacing (L) = 41.34 in. Fig. 6.1 Typical Array Plan View (Section A-A) on Next Page 10/16/2024 APPROVED FOR CONSTRUCTION 11 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 6.0 Design Loads - Downward (Cont.): 6.2 Racking Dimensions for Point Loads (Cont.): Fig. 6.2 Section A-A 6.3 Point Load Summary:Notes: DLsys = 79 lbs./module -Base 2 repeat for larger width arrays. Total DL = (Varies on location and ballast quantity) SLm = 0 lbs./module WLin (no snow) = 594 lbs./module WLin (with snow) = 158 lbs./module Max Total Load Per Base (lbs.) load combinations (ASD) Location Base DL + Snow DL + 0.6Wlin DL + 0.75SLm + 0.75(0.6WLin) South 1 66 155 84 Interior 2 171 349 206 2nd From North 3 142 321 178 North 4 130 219 148 Table 6.1-A Max Total Load per Base (lbs.) Max Contact Pressure Table Per Base (psi) load combinations (ASD)# of Pads Location Base DL + Snow DL + 0.6Wlin DL + 0.75SLm + 0.75(0.6WLin) South 1 4 8 5 Interior 2 9 19 11 2nd From North 3 8 17 10 2 North 4 7 12 8 South 1 2 4 2 Interior 2 5 9 6 2nd From North 3 4 9 5 4 North 4 4 6 4 Table 6.1-B Max Point Load Summary (psi) 10/16/2024 APPROVED FOR CONSTRUCTION 12 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 7.0 Design Loads - Seismic: Seismic Calculations per ASCE 7-16, Chapter 11 - Seismic Design Criteria Chapter 13 - Requirements for Nonstructural Components 7.1 Seismic Load Data: Site Class :D (Ref. Project Information) Seismic Design Category :D (ASCE, Tables 11.6-1 and 11.6-2) Short Period Spectral Resp. (5%) (Ss) :1.266 (Ref. Project Information) 1s Spectral Response (5%) (S1) :0.454 (Ref. Project Information) Bldg. Seismic Imp. Factor (Ie) =1 (ASCE, Table 1.5-2) Adj. MCE Spec. Resp. (Short) (Sms) =Fa*Ss =1.519 (ASCE, Eqn. 11.4-1) Adj. MCE Spec. Resp. (1 sec.) (Sm1) =Fv*S1 =0.838 (ASCE, Eqn. 11.4-2) Short Period Spectral Response (Sds) =2/3(Sms) =1.013 (ASCE, Eqn. 11.4-3) One Second Spectral Response (Sd1) =2/3(Sm1) =0.559 (ASCE, Eqn. 11.4-2) Component Seismic Imp. Factor (Ip) =1 (ASCE, Sec. 13.1.3) Repsonse Modification Factor (Rp) =2.5 (ASCE, Table 13.6-1) Amplification Factor (ap) =1 (ASCE, Table 13.6-1) 7.2 Seismic Design Equations: Lateral Force (Fp) =(ASCE, Eqn. 13.3-1) Lateral Force (FPLmin) =(ASCE, Eqn. 13.3-3) Lateral Force (FPLmax) =(ASCE, Eqn. 13.3-2) Vertical Force (Fpv)) =(ASCE, Eqn. 12.4-4) Lateral Resisting Force (FRL)* =(Factored Load, ASD) Vertical Resisting Force (FRV) =(Factored Load, ASD) * Frictional resistance due to the components weight may be used to resist lateral forces caused by seismic loads. 10/16/2024 APPROVED FOR CONSTRUCTION 13 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 7.0 Design Loads - Seismic (Cont.): 7.3 Lateral Seismic Force Check: The necessity to add mechanical attachments can arise for several reasons. Building code requirements, roof load limits and array shape all may come into play when determining their need. The table below provides the mechanical attachment requirements for each sub-array within this project. Nomenclature: WP = Sub-Array Weight FPL = Lateral Seismic Force FRL = Lateral Seismic Resisting Force Array Information Lateral Force Verification Results Sub- Array Name WP (lbs.) FPL (lbs.) FRL (lbs.) 0.7 FPL - FRL (lbs.) MA's Required Total MA Capacity (lbs.) MA's Provided Acceptable 1.1 11,151 5,421 2,539 1,255 0 0 0 Yes 2.2 11,143 5,417 0 3,792 6 4,550 7 Yes 2.3 24,526 11,923 0 8,346 13 9,100 14 Yes 2.4 40,105 19,497 0 13,648 21 14,950 23 Yes 2.5 27,182 13,215 0 9,250 15 9,750 15 Yes 2.6 38,496 18,714 0 13,100 21 13,650 21 Yes Totals:152,604 lbs 74,187 lbs.2,539 lbs.49,392 lbs.76 52,000 80 Table 7.1 -Summary of Mechanical Attachment Requirements * MA's Required = 0.7 FPL-FRL/MA strength 10/16/2024 APPROVED FOR CONSTRUCTION 14 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 7.0 Design Loads - Seismic (Cont.): 7.3.1 Seismic Displacement of Unattached Solar Arrays: Per ASCE 7-16, Section 13.6.12, the use of non-linear response history(NLRH) analysis is permitted to determine the seismic displacement of non-structural components located on the roof. μ =specific to each array, see table 7.3 Roof Pitch :specific to each array, see table 7.3 lp =1 for all arrays le =1 for all arrays PanelClaw, Inc. has engaged the services of a 3rd party consulting engineer to perform NLRH analysis on its clawFR and clawFRplus product. Utilizing that analysis, and the report contained in the Appendix of this package, we are able to determine the displacement of the arrays during seismic events, for the system design life of 25 years. The distance, called Δ MPV, noted below represents the displacement due to the maximum seismic event with a 700 year MRI. The Δ MPV also incorporates the cumulative displacements, over the arrays design life, of smaller seismic events. As a company policy, PanelClaw, Inc., limits the use of this data to Δ MPV displacement of 48" or less. ΔMPV distances are derived from App. B, "Executive Summary: Seismic Displacement Demand of Unattached (ballast-only) Solar Arrays." Using the ΔMPV value above, ASCE 7-16 has adopted the following equations to set the minimum separation between unattached solar arrays and rooftop obstructions. Table 7.3 below lists the required separation. ARRAY CLEARANCES PER ASCE 7 Condition #Condition Description Minimum Separation Equation 1 Between separate solar arrays of similar construction (0.5)(Mpv) 2 Between a solar array and a fixed object on the roof or solar array of different construction (Mpv) 3 Between a solar array and a roof edge with a qualifying parapet (Mpv) 4 Between a solar array and a roof edge without a qualifying parapet (2.0)(Mpv) >= 4 ft NOTE: YOU SHOULD PROVIDE SUFFICIENT SLACK IN ARRAY ELECTRICAL WIRING TO ACCOMMODATE ALL POTENTIAL ARRAY MOVEMENT. 10/16/2024 APPROVED FOR CONSTRUCTION 15 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 7.0 Design Loads - Seismic (Cont.): 7.3.1 Seismic Displacement of Unattached Solar Arrays (Cont.): Sub-Array Information Required Clearances per Condition (in) Min. Provided Clearance per Condition (in) Is Provided Clearance Acceptable (Y/N) Sub-Array Name(s) μ = Slope (deg) ΔMPV (in) 1 2 3 4 1 2 3 4 1 2 3 4 1.1 0.71 1 6 3 6 6 48 N/A 15 54 54 N/A Y Y Y Table 7.3 - Sub-Array predicted movement, required clearances, provided clearances, and acceptance 10/16/2024 APPROVED FOR CONSTRUCTION 16 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 7.0 Design Loads - Seismic (Cont.): 7.4 Vertical Seismic Force Check: Mechanical attachments may be required for several reasons including building code, roof load limits and array shape. The table below provides the mechanical attachment requirements for each sub-array within this project. Nomenclature: WP = Sub-Array Weight FPV = Vertical Seismic Force FRV = Vertical Seismic Resisting Force Array Information Vertical Force Verification Results Sub- Array Name WP (lbs.) FPV (lbs.) FRV (lbs.) 0.7 FPV - FRV (lbs.) MA's Required Total MA Capacity (lbs.) Total MA's Provided Acceptable 1.1 11,151 2,259 6,691 -5,109 0 0 0 Yes 2.2 11,143 2,257 6,686 -5,106 0 1,845 7 Yes 2.3 24,526 4,968 14,716 -11,238 0 5,243 14 Yes 2.4 40,105 8,124 24,063 -18,376 0 7,653 23 Yes 2.5 27,182 5,506 16,309 -12,455 0 3,474 15 Yes 2.6 38,496 7,798 23,097 -17,639 0 6,524 21 Yes Total: 152,604 lbs.30,911 lbs.91,562 lbs.-69,924 lbs.0 24,739 80 Table7.2 - Summary of Mechanical Attachment Requirements * MA's Required = 0.7 FPV - FRV/MA strength 10/16/2024 APPROVED FOR CONSTRUCTION 17 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Appendix A Appendix A18 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Appendix A 19 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Table of Contents Section:Page # 10/16/2024 APPROVED FOR CONSTRUCTION 2 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1.0 Project Information 4 1.1 General 4 1.2 Building Information 4 1.3 Structural Design Information 5 2.0 Snow Load 6 2.1 Snow Load Data 6 2.2 Snow Load Per Module 6 3.0 Wind Load 7 3.1 Wind Load Data 7 3.2 Roof / Array Zone Map 7 3.3 Wind Design Equations 7 4.0 Design Loads - Dead 8 4.1 Dead Load of the Arrays 8 5.0 Design Loads - Wind 9 5.1.1 Global Wind Uplift Summary Table 9 5.1.2 Global Wind Shear Summary Table 10 6.0 Design Loads - Downward 11 6.1 Downward Wind Load Calculation 11 6.2 Racking Dimensions for Point Loads 11 6.3 Point Load Summary 12 7.0 Design Loads - Seismic 13 7.1 Seismic Load Data 13 7.2 Seismic Design Equations 13 7.3 Lateral Seismic Force Check 14 7.3.1 Seismic Displacement of Unattached Solar Arrays:15 7.4 Vertical Seismic Force Check 17 1851 E Deere Ave 11/13/2024 Appendix A 20 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Appendix A 21 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Appendix A 22 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Appendix A 23 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Appendix A 24 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Appendix B Appendix B25 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Appendix B26 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Appendix B27 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Appendix B28 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Appendix B29 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Appendix: A. Wind Tunnel Tests and Load Analysis for PANELCLAW ROOF MOUNT 10° TILT SOUTH-FACING, CPP Project 19784, Dated 16 April 2024. B. Seismic displacement demand of unattached (ballast-only) solar arrays 10/16/2024 APPROVED FOR CONSTRUCTION 3 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Appendix B30 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 Appendix B31 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 1.0 Project Information: 1.1 General: Project Name:Medtronic Project Location:1851 E Deere Ave, Santa Ana, CA 92705, USA Racking System:clawFR 10 Degree Module:ADANI ASB-M10-144-535 Module Weight:61.73 lbs. Module Tilt:8.99 deg. Module Width:44.61 in. Module Length:89.21 in. Module Area:27.64 sq.ft. Ballast Block Weight:32.60 lbs. 1.2 Building Information: Roof Name Height (ft.)Parapet Height (ft.) Roof 1 20 5.0 Roof 2 30 4.0 Sub-Array Name Pitch (deg.)Membrane Material Coeff. of Friction (μ) 1.1 1 PVC 0.71 2.2 1 PVC 0.71 2.3 1 PVC 0.71 2.4 1 PVC 0.71 2.5 1 PVC 0.71 2.6 1 PVC 0.71 10/16/2024 APPROVED FOR CONSTRUCTION 4 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 1.0 Project Information (Cont.): 1.3 Structural Design Information: ASCE Code:ASCE 7-16 Building Code:2022 CBC Risk Cat.:II Basic Wind Speed (V):95 mph Exposure Category:C Ground Snow Load (Pg):0 psf Is:1 Site Class:D Short Period Spectral Resp. (5%) (Ss):1.266 1s Spectral Response (5%) (S1):0.454 Ie:1 Ip:1 10/16/2024 APPROVED FOR CONSTRUCTION 5 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 2.0 Snow Load: Snow Calculations per ASCE 7-16, Chapter 7 2.1 Snow Load Data: Ground Snow Load (Pg)=0.00 psf (ASCE, Figure 7.2-1) Exposure Factor (Ce)=1 (ASCE, Table 7.3-1) Thermal Factor (Ct)=1.2 (ASCE, Table 7.3-2) Importance Factor (Is)=1 (ASCE, Table 1.5-2) Flat Roof Snow Load (Pf) =0.7*Pg*Ce*Ct*Is=0.00 psf (ASCE 7.3-1) Min Snow Load for Low Slope Roof =Pg*Is =0.00 psf (ASCE 7.3.4) Snow Load on Array (SLA) =0.00 psf SLA Fig. 2.1 - Uniform Roof Snow Load on Array 2.2 Snow Load Per Module: Snow Load per Module (SLM) =Module Projected Area SLA Where; Module Projected Area (Amp) = Module Area * Cos(Module Tilt) Where; Module Area =27.64 sq.ft. Module Tilt =8.99 deg. Amp =27.30 sq.ft. SLM =   Amp     SLA   = 0.00     lbs. 10/16/2024 APPROVED FOR CONSTRUCTION 6 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 3.0 Wind Load: Wind Analysis per ASCE 7-16- Wind Tunnel Procedure, Chapter 31 3.1 Wind Load Data: Basic Wind Speed (Vult) =95 mph (ASCE, Fig. 26.5-1) Exposure Category:C (ASCE, Sec. 26.7.3) Topographic Factor (Kzt) =1 (ASCE, Fig. 26.8-1) Directionality Factor (Kd) =0.85 (ASCE, Table 26.6-1) Exposure Coefficient (Kz) =0.90 (ASCE, Table 26.10-1) Ground Elevation Factor (Ke) =1.00 (ASCE, Table 26.9-1) Velocity Pressure (qz) =0.00256*Kz*Kzt*Kd*Ke*V^2 =17.68 psf (ASCE, Eqn. 26.10-1) 3.2 Roof / Array Zone Map: Figure 3-1. South corner zones – 90-180° wind directions Figure 3-2. North corner zones – 0- 90° wind direction Roof Zone Map Dimensions per CPP Wind Tunnel Study Height (ft.)LB* (ft.)Velocity Pressure (qz) (psf) 20 20.00 17.68 30 30.00 19.25 *LB = Characteristic length per wind tunnel study 3.3 Wind Design Equations: FL = qz Aref GCL FL = sum of lift on panel and deflector. FD = qz Aref GCD FD = sum of drag on panel and deflector. FL - D Companion = qz Aref GCL - D Companion FD - L = The accompanying uplift corresponding to maximum drag. Where qz = Velocity Pressure (Ref. Section 3.1, Wind Load) Aref = Module Area (Ref. Section 1.1, General) GCL GCD , GCL-D Companion= Vary and related to wind zone map (Proprietary Wind Tunnel Coefficients) 10/16/2024 APPROVED FOR CONSTRUCTION 7 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 4.0 Design Loads - Dead: There are two categories of dead load used to perform the structural analysis of the PanelClaw racking system; Dead Load of the Array (DLA) and Dead Load of the Components (DLC). DLA is defined as the weight of the entire array including all of the system components and total ballast used on the array. DLC is defined as the weight of the modules and the racking components within an array. The DLC does not include the ballast used to resist loads on this array. 4.1 Dead Load of the Arrays: Array Information Results Sub- Array Name Number of Modules DLC (lbs.) DLA (lbs.) DLC (lbs.)/module Sub- Array Area (ft.^2) Sub-Array Roof Pressure (DLC) (psf) Sub-Array Roof Pressure (DLA) (psf) Max Allowable Pressure on Roof (psf) Acceptable? 1.1 104 8,054 11,151 77 3,577 2.25 3.12 100.00 Yes 2.2 75 5,830 11,143 78 2,587 2.25 4.31 100.00 Yes 2.3 180 14,029 24,526 78 6,202 2.26 3.95 100.00 Yes 2.4 276 21,588 40,105 78 9,502 2.27 4.22 100.00 Yes 2.5 184 14,468 27,182 79 6,333 2.28 4.29 100.00 Yes 2.6 270 21,022 38,496 78 9,305 2.26 4.14 100.00 Yes Total:  1089 84,991 lbs.152,604 lbs. *Racking component weight range between 13 to 15 pounds per module Table 4.1 - Array Dead Loads and Roof Pressures 10/16/2024 APPROVED FOR CONSTRUCTION 8 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024 5.0 Design Loads - Wind: 5.1.1 Global Wind Uplift Summary Table: The necessity to add mechanical attachments can arise for several reasons. Building code requirements, roof load limits and array shape all may come into play when determining their need. The table below provides the mechanical attachment requirements for each sub-array within this project.  Applied Load Resisting Load Code Check Sub- Array Name FL = Total Wind Uplift (lbs.) DL = Total Dead Load (lbs.) Maximum Allowable Mechanical Attachment Strength (lbs.) Total MA Capacity (lbs.) Calculated Factor of Safety* Check 1.1 10,416 11,151 N/A 0 1.78 OK 2.2 11,929 11,143 525 1,845 1.81 OK 2.3 26,024 24,526 525 5,243 1.91 OK 2.4 44,125 40,105 525 7,653 1.80 OK 2.5 28,704 27,182 525 3,474 1.78 OK 2.6 41,939 38,496 525 6,524 1.79 OK Total:163,137 lbs.152,604 lbs. 24,739 lbs. Table 5.1 Summary of Mechanical Attachment Requirements * Back calculated factor of safety provided to determine factor of safety applied to dead load in lieu of 0.6 in ASCE 7-16 equation 7, BACK CALCULATED FACTOR OF SAFETY = (DEAD LOAD+MECHANICAL ATTACHMENT)/(.6)WIND LOAD 10/16/2024 APPROVED FOR CONSTRUCTION 9 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1851 E Deere Ave 11/13/2024