Laserfiche WebLink
Job No: <br />Drawn by: <br />Sheet: <br />Date: <br />Scale: <br />N.T.S. <br />DA <br />T <br />E <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br /> <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />E: ISTING FLOOR PLAN <br />PROPOSED FLOOR PLAN <br />A-1 <br />10 <br />4 <br />9 <br />2 <br /> <br />T <br />R <br />A <br />S <br />K <br /> <br />A <br />V <br />E <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />B <br /> <br />Ga <br />r <br />d <br />e <br />n <br /> <br />G <br />r <br />o <br />v <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />4 <br />3 <br />Ph <br />o <br />n <br />e <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br />4 <br />1 <br />7 <br />- <br />1 <br />8 <br />3 <br />9 <br /> <br />- <br /> <br />( <br />6 <br />5 <br />7 <br />) <br />7 <br />2 <br />0 <br />- <br />8 <br />5 <br />5 <br />5 <br /> <br />Em <br />a <br />i <br />l <br />: <br /> <br />a <br />r <br />t <br />. <br />d <br />e <br />s <br />i <br />g <br />n <br />. <br />g <br />r <br />o <br />u <br />p <br />2 <br />0 <br />2 <br />2 <br />@ <br />g <br />m <br />a <br />i <br />l <br />. <br />c <br />o <br />m <br />De <br />s <br />i <br />g <br />n <br /> <br />(E)STAFF <br />RESTROOM <br />(N) <br />STORAGE <br /> ROOM <br />(N) <br />STORAGE <br /> ROOM <br />(N) <br />IV ROOM <br />(N) <br />VITALS ROOM <br />MTM PHARMACY <br />(E) <br />WH <br />(E) <br />ROOM 1 <br />FRONT COUNTER <br />FI <br />L <br />I <br />N <br />G <br /> <br />C <br />A <br />B <br />I <br />N <br />E <br />T <br />FI <br />L <br />I <br />N <br />G <br /> <br />C <br />A <br />B <br />I <br />N <br />E <br />T <br />FI <br />L <br />I <br />N <br />G <br /> <br />C <br />A <br />B <br />I <br />N <br />E <br />T <br />FILING <br />CABINET <br />BACK COUNTER <br />(E) <br />WOMEN RR <br />(E) <br />ROOM 2 <br />(E) <br />ROOM 3 <br />(E) <br />ROOM 4 <br /> CABINET <br />(E) <br />ELECTRICAL <br />PANEL <br />1/4" = 1'-0" 1PROPOSED FLOOR PLAN <br />N <br />1/4" = 1'-0" 2 EXISTING FLOOR PLAN <br />(E) UTILITY <br />A <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br /> <br />F <br />O <br />R <br /> <br />LE <br />G <br />A <br />L <br />I <br />Z <br />E <br /> <br />L <br />E <br />G <br />A <br />L <br />I <br />Z <br />E <br /> <br />T <br />E <br />N <br />A <br />N <br />T <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br /> <br />71 <br />4 <br /> <br />S <br /> <br />H <br />a <br />r <br />b <br />o <br />r <br /> <br />B <br />l <br />v <br />d <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />Vi <br />r <br />t <br />u <br />e <br /> <br />M <br />e <br />d <br />i <br />c <br />a <br />l <br /> <br />G <br />r <br />o <br />u <br />p <br />- <br />M <br />T <br />M <br /> <br />P <br />l <br />u <br />s <br /> <br />P <br />h <br />a <br />r <br />m <br />a <br />c <br />y <br />N <br />(E.) FIXED EXTERIOR GLAZING BEHIND <br />(E.) EXTERIOR WALLS NO CHANGE <br />(E.) & (N.) FLOOR PLAN WALL LEGEND: <br />(E) DEMISING WALL <br />(E) <br />MEN RR <br />101D <br />(E.) INTERIOR WALL WAS REMOVED <br />(E.) INTERIOR WALLS NO CHANGE <br />UNPERMIT (N) INTERIOR WALLS <br />10 <br />1 <br />A <br />10 <br />1 <br />A <br />(E) <br />ROOM 1 <br />(E) <br />ROOM 2 <br />(E) <br />ROOM 3 <br />(E) <br />ROOM 4 <br />10 <br />1 <br />B <br />101D <br />101D <br />101D <br />101D <br />101D <br />14 <br />MTM PLUS PHARMACY <br />ENTRANCE <br />VIRTURE MEDICAL GROUP <br />ENTRANCE <br />3 <br />2 <br />6 <br />ACCESSIBLE SIGNAGE KEY NOTES <br />MAIN EXIT DOOR SHALL PROVIDED WITH A DURABLE SIGN OF <br />ONE (1") LETTERS ON CONTRASTING BACKGROUND INDICATING <br />( THESE DOORS SHALL REMAIN UNLOCKED WHEN THIS SPACE <br />IS OCCUPIED) PER SEC. 1008.1.9.3 <br />1 <br />TACTILE EXIT SIGN W./ WORDS "EXIT" (CBC 11B-703.4.2.1)2 <br />INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGNAGE.3 <br />THIS TABLE TO BE OPEN AT ALL TIMES FOR CUSTOMER WITH <br />DISABILITIES CLEAR FOR ACCESSIBLE AT COUNTER MAX. 34" HIGH <br />AND 36" WIDE <br />4 <br />5 <br />6 <br />ALL EXTERIORS ARE SELF-CLOSING, <br />TIGHT-FITTING RODENT-PROOF <br />7 <br />RESTROOM VENTILATION IS LIGHT SWITCH <br />ACTIVATED MECHANICAL EX. FAN <br />8 <br />EXIT SIGNAGE TO COMPLY PER CBC SECTION 1013 <br /> FIRE EXTINGUISHER 2-A:20-B RATED EXTINGUISHER <br />IS REQUIRED FOR EACH 3,000 SF, OF FLOOR AREA <br />AND MUST BE LOCATED SUCH THAT THE TRAVEL <br />DISTANCE DOES NOT EXCEED 30 FEET. ( INSTALLED <br />IN A RECESSED OR SEMI RECESSED CABINET) <br />PANIC HARDWARE9 <br />WAITING AREA <br />WAITING AREA <br />(E) <br />ROOM 5 <br />101D <br />101D <br />101D <br />101D <br />101D <br />101C <br />10 <br />1 <br />D <br />(E) <br />BREAK ROOM <br />EXISTING <br />ENTRANCE <br />101D <br />101D <br />101D <br />101D <br />10 <br />1 <br />E <br />10 <br />1 <br />E <br />101D <br />101D <br />10 <br />1 <br />D <br />(E) UTILITY <br />1 4 <br />101D <br />10 <br />1 <br />C <br />(E) <br />STAFF RR <br />(E) <br />WOMEN RR <br />(E) <br />MEN RR <br />(E) <br />ROOM 5 <br />1 <br />7 <br />9 7 <br />6 <br />(E) <br />WH <br />(E) <br />ELECTRICAL <br />PANEL5 <br />5 <br />ACCESSIBLE RECEPTIONIST <br />ACCESSIBLE RECEPTIONIST <br />3 <br />A-1 <br /># Q. SIZE DESCRIPTION DOOR FINISH FRAME M.F. LOCATION REMARKSTHICK <br />1 3/4"ALUM. <br />DOOR HARDWARE/ HINGERS <br />LOCK, SEALS, DOOR BOTTOM& THRESHOLD <br />2 <br />EXISTING AND NEW DOOR SCHEDULE <br />a/ ALL DOOR HARDWARE TO MEET ADA CODE, <br />b/ VERIFY EXISTING DOORS TO MEET CODE18" HIGH STAINLESS KICKPLATES ON BOTH SIDES <br />TEMP. GLASS <br />MAIN EXIT DOOR SHALL PROVIDED WITH A DURABLE SIGN OF ONE (1") <br />LETTERS ON CONTRASTING BACKGROUND INDICATING (THERE DOOR TO <br />REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED) <br />PUSH - PULL <br />NEW FRONT <br />EXTERIOR 1 DOOR FRONT <br />ENTRANCE DOOR <br />NEW <br />1 <br />101A <br />101B <br />SURFACE CLOSER-P404 1 <br />EDA-695-LCN <br />KICK PLATE-8400 10"x2" <br />LDW-613-IVES <br />LOCK GUARD-LG1-600 <br />1 3/4" <br />1 <br />HALLWAY <br />101C <br />NEW <br />NEW <br />SELF CLOSING <br />1 3/4"INTERIOR WD. SOLID <br />CORE <br />ROOM, <br />RESTROOM <br />SELF-CLOSING <br />LEVER TYPE <br />PAINT SEMI <br />GLOSS <br />WD. <br />3'-0" x6'-8" <br />INTERIOR WD. SOLID <br />CORE <br />PAINT SEMI <br />GLOSS <br />WD. <br />NEW <br />SELF-CLOSING <br />LEVER TYPE <br />13 101D 1 3/4" EXSTING <br />PAINT SEMI <br />GLOSS REAR DOOR EXISTING <br />SELF CLOSING <br />1 101E <br />WD. <br />1 3/4" REAR DOOR <br />PAINT SEMI <br />GLOSS REAR DOOR NEW <br />SELF CLOSINGWD. <br />1. ALL EXIT DOORS SHALL PROVIDE FOR DISABLED ACCESS PER CBC <br />11B-404.2.7. <br />2. HAND-ACTIVATED DOOR OPENING HARDWARE MUST BE MOUNTED <br />BETWEEN 34 AND 48 INCHES ABOVE FINISH FLOOR. <br />3. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT <br />THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT IN <br />ACCORDANCE WITH THE CBC <br />4. DOOR HARDWARE SHALL BE OPERABLE WITH A SINGLE EFFORT <br />WITHOUT REQUIRING THE ABILITY TO GRASP THE HARDWARE (LEVER <br />OR PUSH TYPE IS ACCEPTABLE) PER CBC 11B-404.2.7. <br />5. PER CBC 11B-4-4.2.9, THE MAXIMUM EFFORT TO OPERATE DOORS <br />SHALL NOT EXCEED 5LBS. FOR EXTERIOR AND INTERIOR DOORS, <br />SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO <br />HINGED DOORS AND AT THE CENTER PLACE OF SLIDING OR FOLDING <br />DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS <br />MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. <br />6. PANIC HARDWARE SHALL COMPLY WITH CBC 1008.1.9. <br />7. THE LOWER 10" OF THE DOOR SHALL BE A SMOOTH AND PLANE <br />SURFACE. (NO RECESS OR TRAP). <br />8. MODIFY WIDTH OF DOOR STOP TO ACCOMMODATE TOTAL DOOR <br />THICKNESS, INCLUDING VENEER. <br />9. MINIMUM STRIKE EDGE DISTANCES SHALL BE PROVIDED PER CBC <br />1004.4.9.2.3a. <br />10. THE SWEEP OF A DOOR CLOSER SHALL BE ADJUSTED SO THAT <br />FROM AN OPEN POSITION OF 70 DEGREES THE DOOR WILL TAKE AT <br />LEAST 3 SECONDS TO MOVE TO A POINT 3" FROM THE LATCH AS <br />MEASURED FROM THE LEADING EDGE OF THE DOOR. <br />11. LEVEL LANDINGS SHALL BE PROVIDED ON EACH SIDE OF DOORS. <br />LANDINGS SHALL BE AT THE SAME ELEVATION ON EACH SIDE OF THE <br />DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH <br />OF THE DOOR AND A LENGTH MEASURED IN THE DIRECTION OF <br />TRAVEL OF NOT LESS THAN 44 INCHES PER CBC 1008.1.5, 1008.1.6. <br />12. THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR <br />SWINGS SHALL EXTEND 24" PAST THE STRIKE EDGE OF THE EXTERIOR <br />DOORS AND 18" FOR INTERIOR DOORS <br />13. THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2" LOWER <br />THAN THE THRESHOLD OF THE DOORWAY. BEVEL 1:2 MAX. SLOPE, <br />WHERE THRESHOLD EXCEEDS 1/4" IN HEIGHT. <br />14. EXTERIOR LEVEL LANDING MAY SLOPE UP TO 1/4" PER FOOT IN <br />ANY DIRECTION FOR SURFACE DRAINAGE. SEE CIVIL DRAWINGS FOR <br />GRADE ELEVATIONS. <br />15. WHERE NOTED AND/OR REQUIRED, A DURABLE SIGN WITH <br />LETTERING ON A CONTRASTING BACKGROUND WILL BE PLACED OVER <br />EXIT DOORS STATING "THIS DOOR TO REMAIN UNLOCKED WHEN THE <br />BUILDING IS OCCUPIED" PER CBC 1010.1.9.3. <br />16. PROVIDE INTERNATIONAL SYMBOL OF ACCESSIBILITY AT ALL <br />ACCESSIBLE ENTRANCES PER CBC 11B-216.1 & 11B-703.1 <br />17. PROVIDE CBC COMPLIANT WALL AND DOOR SIGNAGE AT ALL <br />ACCESSIBLE RESTROOMS. <br />18. VALID EXIT DOOR HARDWARE- WHERE PANIC IS NOT REQUIRED. <br />- SELF-RELEASING DOOR HARDWARE WITH INTERCONNECTED <br />SINGLE LOCKING HARDWARE: SINGLE DEADBOLT PROTECTION <br />WITH A SINGLE MOTION EXITING (CO-ACTIVATING) WHEN THE <br />LEVER IS TURNED. THE DEADBOLT RETRACTS WHEN THE <br />INTERIOR LEVER TURNED. <br />- SELF-RELEASING DOOR HARDWARE: THE OUTSIDE LEVER IS <br />LOCKED AND UNLOCKED BY THE KEY FROM HE EXTERIOR. THE <br />INSIDE LEVER IS ALWAYS UNLOCKED AND PROVIDES A SINGLE <br />MOTION EXITING WHEN THE INTERIOR LEVER IS TURNED. <br />ACCESSIBLE REACH RANGES 3 <br />OBSTRUCTION <br />10" MAX <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />15 <br />" <br />MI <br />N <br />. <br />SIDE REACH <br />OBSTRUCTED <br />OBSTRUCTION <br />10" MAX30" <br />34 <br />" <br /> <br />M <br />A <br />X <br />SIDE REACH <br />ACCESSIBLE @ COUNTER <br />SERVER ROOM <br />DOCTOR' OFFICE <br />EXAM 3 <br />EXAM 2 <br />EXAM 1 <br />VIRTURE <br />MEDICAL <br />GROUP <br />Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort.” <br />CBC Section 11B-404.2.9: <br /> “Maximum effort to operate doors shall not exceed 5 pounds for exterior doors and interior doors, such <br />pull or push effort being applied at right angles to hinged doors and at the center place of sliding or folding <br />doors. Compensating devices or automatic door operators may be utilized to meet the above standards. <br />When fire doors are required, the maximum effort to operate the door may be increased to the minimum <br />allowable by the appropriate administrative authority, not to exceed 15 pounds. <br />2 <br />2 <br />2 2 <br />2 <br />Tactile exit signs shall be required at the following locations: <br />- Each grade-level exterior exit door shall be identified by a tactile exit with the word “EXIT.” <br />- Each exit door that leads directly to a grade-level exterior exit by means of an exit enclosure, <br />or an exit passageway, shall be identified by a tactile exit sign with the words “EXIT ROUTE.” <br />- Each exit access door from an interior room or area to a corridor or hallway, which is required <br />to have a visual exit sign, shall be identified by a tactile exit sign with the words “EXIT ROUTE.” <br />- Each exit door through a horizontal exit shall be identified by a sign with the words “TO EXIT.” <br />CBC 11B-303. <br />There shall be a floor or landing on each side of a <br />door.the floor or landing shall be not more than ½” lower than the threshold of the doorway <br />It is the project designer’s/property owner’s responsibility to show compliance on the drawings with <br />all applicable Federal and State Accessibility Standards. <br />3'-0" x6'-8" <br />3'-0" x6'-8" <br />3'-0" x6'-8" <br />3'-0" x6'-8" <br />9 <br />A-3 <br />10 <br />A-3 <br />2406.3 Identification of Safety Glazing <br />Except as indicated in Section 2406.3.1, each pane of safety glazing installed in hazardous locations shall be <br />identified by a manufacturer's designation specifying who applied the designation, the manufacturer or installer <br />and the safety glazing standard with which it complies, as well as the information specified in Section 2403.1. <br />The designation shall be acid etched, sand blasted, ceramic fired, laser etched, embossed or of a type that once <br />applied, cannot be removed without being destroyed. A label meeting the requirements of this section shall be <br />permitted in lieu of the manufacturer's designation. <br />Exceptions: <br />For other than tempered glass, manufacturer's designations are not required, provided that the building official <br />approves the use of a certificate, affidavit or other evidence confirming compliance with this code. <br />Tempered spandrel glass is permitted to be identified by the manufacturer with a removable paper designation. <br />2406.3.1 Multipane Assemblies <br />Multipane glazed assemblies having individual panes not exceeding 1 square foot (0.09 m2) in exposed areas <br />shall have one pane or more in the assembly marked as indicated in Section 2406.3. Other panes in the <br />assembly shall be marked "CPSC 16 CFR Part 1201" or "ANSI Z97.1," as appropriate. <br />2406.3.1 Multipane Assemblies <br />9 <br />A-3 <br />10 <br />A-3 <br />EXISTING <br />EXITEXISTING <br />EXIT <br />Shall be openable from the <br />inside without the use of a <br />key or any special <br />knowledge or effort. <br />EXSTING <br />HALLWAY <br />714 S Harbor Blvd <br />2/25/2025