Loading...
HomeMy WebLinkAbout1001_Grand_P0115404_2024-194213_Grading - PlanP P C GR A N D A V E N U E N 0 0 ° 0 6 ' 2 0 ' ' W 66 0 . 0 1 ' L L (E) CC (E) AC (E) AC (E) AC (E) AC (E) PA (E) PA (E) PA (E) AC L (E) AC(E) AC (E) CC (E) BUILDING FF = 108.90' GB GB GB 108.45 FS (108.68 FS) (108.55 FS) (108.53 FS) (108.00 FS) 108.79 FS 108.88 FS 108.88 FS 107.38 FS 108.44 FS (107.85 FS)(108.14 FS) (106.59 FS=TC) (106.63 FS=TC) 108.65 FS 108.61 FS 108.67 FS 108.56 FS 108.75 FS 108.75 FS (108.64 FS)1. 0 1 % 1. 5 1 % 1. 8 0 % 1. 8 0 % 0.74% 1.00% 1. 8 2 % 1.93% 0. 4 9 % 1.98 %2.75 % 3.7 7 % 1.94% 1. 2 1 % 4.43% 1. 8 0 % 0.08% 1. 8 6 % 108.35 FS 1. 8 0 % 106.64 FS 107.18 TC 107.14 TC 106.68 FS 0.17%0.47%0.04% 3.3 0 % 1.47 % 1.17 % 108.90 FF 108.88 TH (107.69 FS=FG) 1. 2 8 % GB3. 0 1 % GB GB 107.48 FS 108.47 FS 108.88 FS 0.92% 108.97 TC 109.15 TC 109.25 TC 109.25 TC 108.75 FS 107.98 TC 107.88 TC 108.85 TC 108.47 FS 108.95 TC 109.11 TC 109.03 TC 109.08 TC109.14 TC (108.58 FS)109.25 TC 0.53% 1. 8 0 % 108.66 FS 109.17 TC 1. 8 4 % (107.45 FG) (107.54 FG) (108.65 FS) (108.19 FS) (108.67 FS) (108.02 FG) (108.51 FG) (108.23 FG) ENTRANCE DOOR (108.53 FS) EXISTING GRADEFINISHED SURFACE 6' CONCRETE CURB PER DETAIL 4/C-4.0 4" THICK CONCRETE PAVEMENT 4" THICK CRUSHED AGGREGATE 12" COMPACTED SUBGRADE 90% RELATIVE COMPACTION AC OVERLAY PER DETAIL 3/C-4.0 (E) CRUSHED AGGREGATE GB GB GB GBPL (E) BUILDING 4" THICK CONCRETE PAVEMENT 4" THICK CRUSHED AGGREGATE 12" COMPACTED SUBGRADE 90% RELATIVE COMPACTION 0" CONCRETE CURB GB GB (FF = 108.90)FINISHED SURFACE EXISTING GRADE AC OVERLAY PER DETAIL 3/C-4.0 TRUNCATED DOME PER DETAIL 7/C-4.0 NEW 6" CONCRETE CURB PER DETAIL 4 ON SHEET C-4.0 4" THICK CONCRETE PAVEMENT 4" THICK CONCRETE PAVEMENT 12" COMPACTED SUBGRADE 90% RELATIVE COMPACTION EXISTING PLANTER AREA EXISTING PLANTER AREA ESTIMATED EARTHWORK QUANTITY NOTES: ESTIMATED CUT = 3.73 CU YD ESTIMATED FILL = 8.15 CU YD ESTIMATED NET = 4.43 CU YD (FILL) SCALE:1"=10' 0510 2000100 SURVEYOR DATE: JULY 15, 2024 FLORENTINO FERRER FERRER & ASSOCIATES LAND SURVEYORS & ENGINEERS 16388 COLIMA ROAD, UNIT 206-L HACIENDA HEIGHTS, CA 91745 SURVEYOR'S NOTES 1.THIS MAP REPRESENTS A TOPOGRAPHIC SURVEY OF VISIBLE FIELD CONDITIONS AT THE TIME OF THIS SURVEY. NO EASEMENTS, COVENANTS, CONDITIONS, OR RESTRICTIONS HAVE BEEN DETERMINED EXCEPT THOSE SHOWN. 2.THE HORIZONTAL BASIS FOR THIS SURVEY IS N 00°06'20" W GRAND AVENUE PER TRACT NO. 3841 SHEET 2 OF 2 IN THE CITY OF SANTA ANA, COUNTY OF ORANGE, STATE OF CALIFORNIA. 3.THE VERTICAL BASIS FOR THIS SURVEY IS DESCRIBED BY OCS 2001 - DISTURBED - FD 3 3 4" OCS ALUMINUM BM DISK STAMPED "3B-73-68", SET IN THE TOP OF THE N END OF A CONCRETE HEAD WALL. MONUMENT IS LOCATED IN THE NE CORNER OF THE INTERSECTION OF GRAND AVE AND THE SANTA FE/TOPEKA RAILWAY, 42.8' E'LY OF THE CENTERLINE OF GRAND AVE AND 51' N'LY OF THE MOST N'LY RAIL ALONG THE RAILWAY. MONUMENT IS SET LEVEL WITH THE SIDEWALK. ELEVATION = 116.36' 4.REFER TO AUTOCAD DWG FILE FOR ADDITIONAL SURVEY POINTS AND DATA FEATURES NOT SHOWN HERE. SURVEY INFORMATION: FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . SITE GRADING PLAN AND SECTIONS 5 C-3.0 2 C-3.0 C-3.0 1 GRADING SECTION SCALE:H 1:20 V 1:5 1 GRADING SECTION SCALE:H 1:20 V 1:5 2 3.0C-3.0 SITE GRADING PLAN AND SECTIONS 1.THE ESTIMATED QUANTITIES PROVIDED ABOVE ARE FOR REFERENCE ONLY TO BE USED FOR JURISDICTIONAL PLAN CHECKING AND PERMITTING PURPOSES ONLY. 2.ESTIMATED EARTHWORK ABOVE IS BASED ON DESIGN FINISH GRADES TO EXISTING GRADES IN SURVEY. THE ESTIMATED EARTHWORK DOES NOT CONSIDER THE THICKNESS OF EACH PAVEMENT MATERIAL, FOUNDATION AND SLAB ON GRADE VOLUMES, THE REMOVAL OF ANY UNSUITABLE MATERIAL, AND THE REMOVAL OF EXISTING BASEMENTS, PITS, VAULTS, TOP SOIL OR VEGETATION. 3.THE ESTIMATED EARTHWORK QUANTITIES DO NOT INCLUDE SHRINKAGE FACTORS DUE TO COMPACTION OR ANY OVER EXCAVATION QUANTITIES. 4.ESTIMATED EARTHWORK QUANTITIES ABOVE ASSUME THAT ALL ON-SITE MATERIALS ARE SUITABLE FOR BACKFILLING. HOWEVER, ACTUAL EXISTING ON-SITE MATERIALS AND IMPORTED MATERIALS MUST FIRST BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO INSTALLATION, REMOVAL, OR REPLACEMENT. 5.INFORMATION SHOWN WITHIN THE CONSTRUCTION DOCUMENTS WAS DERIVED FROM AS-BUILT PLANS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THE CONSTRUCTION DOCUMENTS. IF ANY DISCREPANCIES ARISE, CONTRACTOR SHALL INFORM OWNER AND DESIGN TEAM. 3 C-3.0 GRADING SECTION SCALE:H 1:20 V 1:5 3 3.0 Behrooz Sarlak 4/7/2025 TYP TYP TYP 27 26 26 28 25 21 22 22 22 4 1 33 2 6 5 5 5 P P C L L L GR A N D A V E N U E N 0 0 ° 0 6 ' 2 0 ' ' W 66 0 . 0 1 ' (E) CC (E) AC (E) AC (E) AC (E) AC (E) PA (E) PA (E) PA (E) AC (E) AC(E) AC (E) BUILDING FF = 108.90' 29 29 29 29 30 31 31 24 31 32 32 53.04' 69.11' 9. 0 0 ' 33.81' 5 17.49' 30 . 8 7 ' 8. 6 7 ' LIMIT OF REMOVAL LIMIT OF REMOVAL LIMIT OF REMOVAL 33 23 5 5 34 9. 0 0 ' 20 . 9 1 ' 22 22 22 TYP TYP TYP 17.03' 4.79' (E ) C O N C R E T E S I D E W A L K 1 REMOVAL NOTES: 2 3 4 5 6 REMOVE EXISTING 4" AC PAVEMENT AND 4" BASE MATERIAL, FULL DEPTH. REMOVE EXISTING 4" CONCRETE PAVEMENT AND BASE MATERIAL, FULL DEPTH. GRIND 1.5" OF EXISTING AC PAVEMENT IN PREPARATION OF AC OVERLAY PER DETAIL 3 ON SHEET C-4.0. CLEAR, GRUB AND REMOVE EXISTING TURF/PLANTER/BUSH/GRAVEL EXPOSED SUBGRADE AREA. REMOVE EXISTING SHRUBS AND ROOTS IN ITS ENTIRETY. REMOVE EXISTING CONCRETE WHEELSTOP IN ITS ENTIRETY. REMOVE EXISTING TRUNCATED DOMES IN ITS ENTIRETY. PROTECT IN PLACE EXISTING TREE IN ITS ENTIRETY. PROTECT IN PLACE EXISTING CONCRETE WHEELSTOP IN ITS ENTIRETY. PROTECT IN PLACE EXISTING METAL COVER IN ITS ENTIRETY. PROTECT IN PLACE EXISTING POST INDICATOR VALVE IN ITS ENTIRETY PROTECT IN PLACE EXISTING DRAIN INLET IN ITS ENTIRETY. PROTECT IN PLACE EXISTING UTILITY VAULT IN ITS ENTIRETY. PROTECT IN PLACE EXISTING FIRE DEPARTMENT CONNECTION IN ITS ENTIRETY. PROTECT IN PLACE EXISTING FIRE HYDRANT IN ITS ENTIRETY. PROTECT IN PLACE EXISTING ASPHALT CONCRETE. PROTECT IN PLACE EXISTING BUILDING, FOUNDATION AND ALL APPURTENANCES IN ITS ENTIRETY PROTECT IN PLACE EXISTING PLANTER AREA. PROTECT IN PLACE EXISTING CONCRETE WALK. PROTECT IN PLACE EXISTING PIPE. PROTECT IN PLACE EXISTING UTILITY PULLBOX IN ITS ENTIRETY. PROTECT IN PLACE EXISTING BOLLARDS IN ITS ENTIRETY. PROTECT-IN-PLACE NOTES: 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 REMOVAL LEGEND: REMOVE EXISTING 4" AC PAVEMENT AND 4" BASE MATERIAL, FULL DEPTH. CLEAR, GRUB AND REMOVE EXISTING GRASS/PLANTER/BUSH/GRAVEL EXPOSED SUBGRADE AREA. REMOVE EXISTING SHRUBS AND ROOTS IN ITS ENTIRETY. GRIND 1.5" OF EXISTING AC PAVEMENT IN PREPARATION OF AC OVERLAY PER DETAIL 3 ON SHEET C-4.0. REMOVE EXISTING 4" CONCRETE PAVEMENT AND BASE MATERIAL, FULL DEPTH. LIMIT OF REMOVAL REMOVE EXISTING TRUNCATED DOMES IN ITS ENTIRETY. SCALE:1"=10' SITE DEMOLITION PLAN 0510 2000100 FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . SITE DEMOLITION PLAN 3 CD-1.0 Behrooz Sarlak 4/7/2025 3 1 2 2 1 2 1 P P C L L L GR A N D A V E N U E N 0 0 ° 0 6 ' 2 0 ' ' W 66 0 . 0 1 ' (E) CC (E) AC (E) AC (E) AC (E) AC (E) PA (E) PA (E) AC (E) AC 1 2 1 2 1 2 (E) AC 10 SE-1 SE-8 SE-1 SE-8 SE-1 SE-8 4 SE-1 SE-8 TC-1 WM-9 EC-2 EC-2 WM-1 WM-3 NS-3 NS-3 NS-3 NS-3 NS-3 5 6 WM-8 EC-2 SE-7 1 CONSTRUCTION NOTES: INSTALL GRAVEL BAGS UNTIL THE COMPLETION OF THE SITE CONSTRUCTION. REFER TO DETAIL 2 ON SHEET C-5.1. SILT FENCE PER DETAIL 6 ON SHEET C-5.1. STABILIZED CONSTRUCTION ENTRANCE/EXIT PER DETAIL 4 ON SHEET C-5.1. PROPOSED AREA FOR TEMPORARY TOILETS. CONTRACTOR TO VERIFY EXACT LOCATION AND COORDINATE WITH THE CONTRACTOR PROJECT MANAGER. PROPOSED AREA FOR MATERIAL DELIVERY AND STORAGE. CONTRACTOR TO VERIFY EXACT LOCATION AND COORDINATE WITH THE CONTRACTOR PROJECT MANAGER. REFER TO DETAIL 5 ON SHEET C-5.1. CONCRETE WASTE MANAGEMENT -WM8. 2 3 4 5 6 1.LOCATION FOR ANY DESIGNATED STOCKPILES SHALL BE COORDINATED AND DETERMINED BY THE CONTRACTOR ON-SITE. CONTRACTOR SHALL APPLY ALL APPLICABLE BMP'S TO PROTECT THE STOCKPILE AS OUTLINED IN DETAIL 8 ON SHEET C-5.1. 2.CONTRACTOR SHALL FROM TIME TO TIME MONITOR THE CONSTRUCTION SITE TO CLEAN AND SWEEP MATERIALS TRACKED OFF SITE. 3.ALL BMP'S, SILT FENCES, ETC., SHALL BE MONITORED AND MAINTAINED BY THE NTP1 CONTRACTOR FOR THE ENTIRE DURATION OF THE CONTRACT. 4.CONTRACTOR SHALL NOT DISCHARGE POLLUTANTS DOWNSTREAM OF THE SETTLING BASIN/OIL SEPARATOR. THESE POLLUTANTS INCLUDE LUBRICANTS, FUELS, CHEMICALS, AND BITUMENS. CONTROL USE OF LUBRICATING OILS, HYDRAULIC FLUIDS, GREASES, AND OTHER SUCH PRODUCTS. PROMPTLY CLEAN UP AND PROPERLY DISPOSE OF MATERIALS CONTAMINATED BY SPILLAGE OR LEAKAGE OF PRODUCTS. 5.CONTRACTOR SHALL PROTECT ALL EXISTING DRAIN INLETS WITHIN A 500-FT RADIUS FROM THE CENTER OF THE SITE TO PREVENT NON-STORMWATER RUNOFF FROM ENTERING THE STORM DRAIN SYSTEM. 6.FOR EROSION CONTROL GENERAL NOTES, AND MISCELLANEOUS REQUIREMENTS, SEE SHEET C-5.1. SHEET NOTES: LEGEND: GRAVEL BAG SILT FENCE SCALE:1"=10' EROSION CONROL PLAN 0510 2000100 FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . EROSION CONTROL PLAN 7 C-5.0 Behrooz Sarlak 4/7/2025 SHEET NO.DESCRIPTION CD-1.0 GENERAL NOTES, LEGENDS, AND ABBREVIATIONS SITE DEMOLITION PLAN SHEET INDEX: C-1.0 EXISTING CONDITIONSC-1.1 CONSTRUCTION LEGEND: ABBREVIATIONS: AC ASPHALT CONCRETE BACK OF SIDEWALKBSW OVERALL SITE CONTROL PLANC-2.0 SITE GRADING PLAN AND SECTIONSC-3.0 C-4.0 VICINITY MAP NOT TO SCALE MISCELLANEOUS DETAILS BS BLUE STRIPE CONCRETEC/CONC/CC CAR STOPCRS CONCRETE SLABCS DRAIN INLETDI DOUBLE WHITE STRIPEDWS EDGE OF CONCRETEEC EDGE OF PAVEMENTEP EDGE OF GUTTEREG ELECTRIC PULL BOXEPB FLOW LINEFL FIRE DEPARTMENT CONNECTIONFDCONN GROUNDGRD FINISH FLOORFF FIRE HYDRANTFH GRADE BREAKGB METAL COVERMC PULL BOXPB POST INDICATOR VALVEPIV ROOF DRAINRD TOP CURBTC TRUNCATED DOME PADTDP THRESHOLDTHR TRAFFIC SIGNAL PULL BOXTSPB WHITE STRIPEWS PROPERTY LINEPL CENTER LINECL E WAKEHAM AVE E HUNTER AVE NORMANDY PL S G R A N D A V E PROJECT SITE GENERAL NOTES: ALL WORK PERFORMED IN THIS CONTRACT SHALL CONFORM TO: A.PROJECT SPECIFICATIONS. B.ALL SHALL CONFORM TO THE LATEST EDITION AND SUPPLEMENTS OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (SSPWC) AND AMERICAN PUBLIC WORKS ASSOCIATION (APWA). C.2022 CALIFORNIA BUILDING CODE. D.CITY OF SANTA ANA PUBLIC WORKS STANDARD PLANS. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE WORK SPECIFIED ON THE DRAWINGS AND WITHIN THE VARIOUS NOTES SHOWN HEREIN. THE EXISTING CONDITIONS SHOWN DIAGRAMMATICALLY ON THE PLANS ORIGINATED FROM AS-BUILT DRAWINGS AND FIELD SURVEY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE AND VERIFY THE EXACT EXISTING CONDITIONS UNLESS CONCEALED BEFORE SUBMITTING HIS BID. ANY DISCREPANCY SHALL BE REPORTED IMMEDIATELY TO THE OWNER USING THE PROPER REQUEST FOR INFORMATION FORMS PRIOR TO SUBMITTING HIS BID FOR PROPER ACTION. THE CONTRACTOR SHALL PROTECT ALL EXISTING STRUCTURES IN THE AREA OF WORK WHICH ARE NOT INCLUDED IN THIS CONSTRUCTION. ANY DAMAGE RESULTING FROM THIS WORK SHALL BE REPAIRED AND/OR REPLACED AT NO ADDITIONAL COST TO THE OWNER. UNDERGROUND SERVICE ALERT: BEFORE COMMENCING ANY EXCAVATION, THE CONTRACTOR SHALL OBTAIN AN UNDERGROUND SERVICE ALERT INQUIRY I.D. NUMBER BY CALLING 1-800-422-4133. TWO (2) WORKING DAYS SHALL BE ALLOWED AFTER THE I.D. NUMBER IS OBTAINED AND BEFORE THE EXCAVATION WORK IS STARTED THAT UTILITY OWNERS CAN BE NOTIFIED. PROTECTION AND RESTORATION OF EXISTING IMPROVEMENTS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF PUBLIC AND PRIVATE PROPERTY ADJACENT TO THE WORK PER SECTION 7-9 OF THE STANDARD SPECIFICATIONS. REMOVALS: ALL SITE PREPARATION AS INDICATED SHALL BE MADE UNDER THE CONTINUOUS INSPECTION OF THE INSPECTOR OF RECORD (IOR) AND OWNER AUTHORIZED REPRESENTATIVE (OAR). SECURE THE REQUIRED PERMIT FROM THE CALIFORNIA DIVISION OF INDUSTRIAL SAFETY FOR THE CONSTRUCTION OF TRENCHES, SHORING OR EXCAVATIONS WHICH ARE 5 FEET OR DEEPER OR WORK THAT MAY JEOPARDIZE THE WORKERS. SHORING CALCULATIONS SHALL BE PROVIDED AS REQUIRED FOR APPROVAL AND PERMITTING. THE CONTRACTOR SHALL KEEP THE CONSTRUCTION AREA SUFFICIENTLY DAMPENED TO CONTROL DUST CAUSED BY WORK ACTIVITIES AS REQUIRED BY THE JURISDICTIONAL AGENCY. ALL FILL OR BACKFILL SHALL BE COMPACTED TO AT LEAST 90% MDD (MAXIMUM DRY DENSITY) PER ASTM D-1557. CONSTRUCTION STAKING AND ADJUSTMENTS FOR IMPROVEMENTS SHOWN ON THESE PLANS SHALL BE PERFORMED BY A LICENSED LAND SURVEYOR PAID FOR BY THE CONTRACTOR AND INCLUDED IN THE CONTRACT. VOIDS RESULTING FROM REMOVAL WORK SHALL BE FILLED WITH SUITABLE MATERIALS COMPACTED TO 90% MAXIMUM DENSITY PER ASTM D-1557. IF EXISTING UTILITIES ARE EXPOSED OR DETERMINED TO EXIST UNDER THE CONSTRUCTION LIMITS, CONTRACTOR SHALL PROVIDE A FLAGGED STAKE THAT INDICATES THEIR LOCATION, TYPE OF UTILITY, SIZE, PIPE MATERIAL AND DEPTH. STAKES SHALL BE INSTALLED NO LESS THAN 50' ON CENTER ON STRAIGHT LINES AND AT BENDS. MAINTAIN A RECORD OF LOCATION OF UTILITY MARKERS ON THE AS-BUILT PLAN AND REINSTALL THEM AFTER PAVING. REPLACE BENT OR UNUSABLE MARKERS FOR ALL UTILITY LINES DISCOVERED WITHIN THE WORK AREA. INSTALL BRASS UTILITY MARKERS INDICATING DIRECTIONS OF LINES AT ALL CHANGES IN DIRECTIONS AFTER PAVING. INFORM THE SURVEYOR TO LOCATE AND RECORD ACTUAL LOCATIONS. UNCLOG, CLEAN AND FLUSH THE WORK AREA DRAINAGE SYSTEM AFTER PAVING AND IMMEDIATELY BEFORE A RAIN FORECAST. CALIFORNIA PUBLIC RESOURCES CODE (SECTION 5097.98) AND HEALTH AND SAFETY CODE (SECTION 7050.5) ADDRESS THE DISCOVERY AND DISPOSITION OF HUMAN REMAINS. IN THE EVENT OF DISCOVERY OR RECOGNITION OF ANY HUMAN REMAINS IN ANY LOCATION OTHER THAN A DEDICATED CEMETERY, THE LAW REQUIRES THAT GRADING IMMEDIATELY STOPS AND NO FURTHER EXCAVATION OF DISTURBANCE OF THE SITE, OR ANY NEARBY AREA WHERE HUMAN REMAINS MAY BE LOCATED, OCCUR UNTIL THE FOLLOWING MEASURES HAVE BEEN TAKEN: A.IF THE REMAINS ARE OF NATIVE AMERICAN ORIGIN, THE DESCENDANTS FROM THE DECEASED NATIVE AMERICANS HAVE MADE A RECOMMENDATION FOR THE MEANS OF TREATING OR DISPOSING, WITH APPROPRIATE DIGNITY, OF THE HUMAN REMAINS AND ANY ASSOCIATED GRAVE GOODS. B.IF THE REMAINS ARE OF NATIVE AMERICAN ORIGIN, THE DESCENDANTS FROM THE DECEASED NATIVE AMERICANS HAVE MADE A RECOMMENDATION FOR THE MEANS OF TREATING OR DISPOSING, WITH APPROPRIATE DIGNITY, OF THE HUMAN REMAINS AND ANY ASSOCIATED GRAVE GOODS. ALL EXPORT OF MATERIAL FROM THE SITE MUST GO TO A PERMITTED SITE APPROVED BY INSPECTOR OF RECORD OR A LEGAL DUMPSITE. RECEIPTS FOR ACCEPTANCE OF EXCESS MATERIAL BY A DUMPSITE ARE REQUIRED AND MUST BE PROVIDED TO THE INSPECTOR OF RECORD UPON REQUEST. ANY ADDITIONAL SURVEYS OR TESTING AS A RESULT OF CONTRACTOR ERROR OR MISINFORMATION WILL BE CHARGED TO THE CONTRACTOR. SITE BOUNDARIES, EASEMENTS, DRAINAGE DEVICES, RESTRICTED USE AREAS SHALL BE LOCATED PER CONSTRUCTION STAKING BY A LICENSED SURVEYOR. PRIOR TO GRADING, AS REQUESTED BY THE INSPECTOR OF RECORD, ALL PROPERTY LINES, EASEMENTS, AND RESTRICTED USE AREAS SHALL BE STAKED. A COPY OF THE APPROVED GRADING PLANS MUST BE IN THE POSSESSION OF A RESPONSIBLE PERSON AND AVAILABLE AT THE SITE AT ALL TIMES. CONTRACTOR SHALL INSTALL TEMPORARY FENCING AROUND THE PERIMETER OF THE CONSTRUCTION SITE AND STAGING AREA. FENCING SHALL BE MINIMUM 6 FEET TALL AND SHALL HAVE A DUST/VISION BARRIER ALONG THE FULL LENGTH. THE DUST/VISION BARRIER SHALL EXTEND THE LENGTH OF THE CONSTRUCTION SITE. THE FENCING SHALL BE ANCHORED TO THE SURFACE AND SHALL BE ABLE TO WITHSTAND A 200-POUND HORIZONTAL POINT LOAD IN ANY DIRECTION. TEMPORARY FENCING POLES AND GATES POST SHALL BE DRIVEN INTO THE GROUND. FENCE STANDS WILL NOT BE ALLOWED EXCEPT FOR AREAS WHERE EXISTING CONCRETE IS TO REMAIN PROTECT IN PLACE. WORK AREA AND STAGING AREA SHALL BE SECURE AT ALL TIMES. THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY, AND SHALL NOT BE LIMITED TO NORMAL WORKING HOURS. THE PROPOSED GRADE IS THE FINAL GRADE AND NOT THE ROUGH GRADE. THE CONTRACTOR SHALL SUBTRACT THE THICKNESS OF THE PAVED SECTION AND/OR LANDSCAPE TOPSOIL SECTION TO ARRIVE AT THE ROUGH GRADE ELEVATION. CONSTRUCT STRAIGHT GRADES BETWEEN ELEVATIONS SHOWN ON PLAN UNLESS INTERRUPTED BY A GRADE CHANGE LINE. ANY DEVIATION FROM THE GRADING PLAN MUST HAVE PRIOR APPROVAL FROM THE ENGINEER OF RECORD. GRADE LAWN, TURF, AND PLANTING AREA 1-1/2" MAX AT ACCESSIBLE PATH OF TRAVEL AND 2" MAX AT OTHER AREAS BELOW DESIGN GRADES INDICATED. THE CONTRACTOR SHALL CONTACT DIG ALERT BY DIALING 811 AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION TO NOTIFY UTILITY OWNERS. HAND DIG ONLY AT LOCATION WHERE UNDERGROUND UTILITIES NEED TO BE PROTECTED IN PLACE. 8. 7. 6. 5. 4. 3. 2. 1. 9. 10. 11. 12. 13. 14. 15. 16. 18. 17. 19. 20. 21. 22. 24. 23. PALM TREE PULL BOX DRAIN INLET PIPE FIRE HYDRANT ROOF DRAIN CONTOUR LINE PROPERTY LINE CENTER LINE C L PILLAR/BUILDING PL POST INDICATOR VALVE FIRE DEPARTMENT CONNECTION # # - DIA IN INCHES CONSTRUCT NEW 4" THICK CONCRETE PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE PER DETAIL 1 ON SHEET C-4.0. CONSTRUCT NEW 4" THICK PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE (CAB) PER DETAIL 2 ON SHEET C-4.0. INSTALL NEW CAST IN PLACE TRUNCATED DOMES PER DETAIL 7 ON SHEET C-4.0 NEW STRIPING PER ARCHITECTURAL DRAWINGS. REMOVE EXISTING AC PAVEMENT AND BASE MATERIAL, FULL DEPTH. REMOVE EXISTING CONCRETE PAVEMENT AND BASE MATERIAL, FULL DEPTH. GRIND 1.5" OF EXISTING AC PAVEMENT IN PREPARATION OF AC OVERLAY PER DETAIL 3 ON SHEET C-4.0. CLEAR, GRUB, AND REMOVE EXISTING GRASS/PLANTER/BUSH/ GRAVEL EXPOSED SUBGRADE AREA. REMOVE EXISTING SHRUBS AND ROOTS IN ITS ENTIRETY. LIMIT OF WORK ------------------------------------------------------------------------ LIMIT OF REMOVAL ------------------------------------------------------------------- OVERLAY WITH NEW LAYERS OF AC PAVEMENT A MINIMUM OF 1.5" PER DETAIL 3 ON SHEET C-4.0. SURVEYOR DATE: JULY 15, 2024 FLORENTINO FERRER FERRER & ASSOCIATES LAND SURVEYORS & ENGINEERS 16388 COLIMA ROAD, UNIT 206-L HACIENDA HEIGHTS, CA 91745 APN NUMBER 402-322-01 SURVEYOR'S NOTES 1.THIS MAP REPRESENTS A TOPOGRAPHIC SURVEY OF VISIBLE FIELD CONDITIONS AT THE TIME OF THIS SURVEY. NO EASEMENTS, COVENANTS, CONDITIONS, OR RESTRICTIONS HAVE BEEN DETERMINED EXCEPT THOSE SHOWN. 2.THE HORIZONTAL BASIS FOR THIS SURVEY IS N 00°06'20" W GRAND AVENUE PER TRACT NO. 3841 SHEET 2 OF 2 IN THE CITY OF SANTA ANA, COUNTY OF ORANGE, STATE OF CALIFORNIA. 3.THE VERTICAL BASIS (BENCHMARK) FOR THIS SURVEY IS DESCRIBED BY OCS 2001 - DISTURBED - FD 3 3 4" OCS ALUMINUM BM DISK STAMPED "3B-73-68", SET IN THE TOP OF THE N END OF A CONCRETE HEAD WALL. MONUMENT IS LOCATED IN THE NE CORNER OF THE INTERSECTION OF GRAND AVE AND THE SANTA FE/TOPEKA RAILWAY, 42.8' E'LY OF THE CENTERLINE OF GRAND AVE AND 51' N'LY OF THE MOST N'LY RAIL ALONG THE RAILWAY. MONUMENT IS SET LEVEL WITH THE SIDEWALK. ELEVATION = 116.36' 4.REFER TO AUTOCAD DWG FILE FOR ADDITIONAL SURVEY POINTS AND DATA FEATURES NOT SHOWN HERE. SURVEY INFORMATION: FS FG FINISHED SURFACE FINISHED GRADE REMOVAL LEGEND: CONCRETEC/CONC/CC CONCRETEC/CONC/CC CONCRETEC/CONC/CC CONCRETEC/CONC/CC CONCRETEC/CONC/CC CRUSHED AGGREGATE BASECAB PLANTER AREAPA MAXIMUM DRY DENSITYMDD 1.THE ESTIMATED QUANTITIES PROVIDED ABOVE ARE FOR REFERENCE ONLY TO BE USED FOR JURISDICTIONAL PLAN CHECKING AND PERMITTING PURPOSES ONLY. 2.ESTIMATED EARTHWORK ABOVE IS BASED ON DESIGN FINISH GRADES TO EXISTING GRADES IN SURVEY. THE ESTIMATED EARTHWORK DOES NOT CONSIDER THE THICKNESS OF EACH PAVEMENT MATERIAL, FOUNDATION AND SLAB ON GRADE VOLUMES, THE REMOVAL OF ANY UNSUITABLE MATERIAL, AND THE REMOVAL OF EXISTING BASEMENTS, PITS, VAULTS, TOP SOIL OR VEGETATION. 3.THE ESTIMATED EARTHWORK QUANTITIES DO NOT INCLUDE SHRINKAGE FACTORS DUE TO COMPACTION OR ANY OVER EXCAVATION QUANTITIES. 4.ESTIMATED EARTHWORK QUANTITIES ABOVE ASSUME THAT ALL ON-SITE MATERIALS ARE SUITABLE FOR BACKFILLING. HOWEVER, ACTUAL EXISTING ON-SITE MATERIALS AND IMPORTED MATERIALS MUST FIRST BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO INSTALLATION, REMOVAL, OR REPLACEMENT. 5.INFORMATION SHOWN WITHIN THE CONSTRUCTION DOCUMENTS WAS DERIVED FROM AS-BUILT PLANS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THE CONSTRUCTION DOCUMENTS. IF ANY DISCREPANCIES ARISE, CONTRACTOR SHALL INFORM OWNER AND DESIGN TEAM. ESTIMATED EARTHWORK QUANTITY NOTES: ESTIMATED CUT = 3.73 CU YD ESTIMATED FILL = 8.15 CU YD ESTIMATED NET = 4.43 CU YD (FILL) REMOVE EXISTING TRUNCATED DOME IN ITS ENTIRETY. FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . GENERAL NOTES, LEGENDS, AND ABBREVIATIONS Underground Service Alert of Southern California Know what's below. before you dig.Call R 1 UTILITY WATER PURVEYOR CITY IF SANTA ANA WATER DIVISION COSTUMER SERVICE: 714 647 5000 EMAIL: water@santa-ana.org WEBSITE: www.santa-ana.org/water UTILITY SEWER PURVEYOR CITY IF SANTA ANA PUBLIC WORKS AGENCY COSTUMER SERVICE: 714 647 3380 EMAIL:publicworks@santa-ana.org WEBSITE: www.santa-ana.org/publicworks UTILITY STORM DRAIN PURVEYOR CITY IF SANTA ANA PUBLIC WORKS AGENCY COSTUMER SERVICE: 714 647 3380 EMAIL:publicworks@santa-ana.org WEBSITE: www.santa-ana.org UTILITY INFORMATION 1.ALL GRADING SHALL COMPLY WITH THE LATEST CBC CHAPTERS 18 AND 33, AND APPENDIX J AND THE SANTA ANA MUNICIPAL CODE. A CITY GRADING PERMIT IS REQUIRED FOR GRADING. 2.GRADING SHALL NOT BE STARTED WITHOUT FIRST NOTIFYING THE CITY GRADING INSPECTOR. A PRE-GRADING MEETING ON THE SITE IS REQUIRED BEFORE STARTING OF GRADING WITH THE FOLLOWING PEOPLE PRESENT: GRADING CONTRACTOR, DESIGN CIVIL ENGINEER, GEOTECHNICAL ENGINEER, GRADING INSPECTOR AND WHEN REQUIRED, THE ARCHAEOLOGIST AND PALEONTOLOGIST. THE REQUIRED INSPECTIONS FOR GRADING WILL BE EXPLAINED AT THIS MEETING. 3.AN APPROVED COPY OF THE GRADING PLANS SHALL BE ON THE PERMITTED SITE WHILE WORK IS IN PROGRESS. 4.THE DESIGN CIVIL ENGINEER SHALL BE AVAILABLE DURING THE GRADING TO VERIFY COMPLIANCE WITH THE PLANS, SPECIFICATIONS, CODE AND ANY SPECIAL CONDITIONS OF THE PERMIT WITHIN HIS PURVIEW. 5.THE GEOTECHNICAL ENGINEER SHALL PERFORM PERIODIC INSPECTIONS AND SUBMIT A COMPLETE REPORT AND MAP UPON COMPLETION OF THE ROUGH GRADING. THE COMPACTION REPORT AND APPROVAL FROM THE GEOTECHNICAL ENGINEER SHALL INDICATE THE TYPE OF FIELD TESTING PERFORMED. EACH TEST SHALL BE IDENTIFIED WITH THE METHOD OF OBTAINING THE IN-PLACE DENSITY, WHETHER SAND CONE OR DRIVE RING, AND SHALL BE SO NOTED FOR EACH TEST. SUFFICIENT MAXIMUM DENSITY DETERMINATIONS SHALL BE PERFORMED TO VERIFY THE ACCURACY OF THE MAXIMUM DENSITY CURVES BY THE FIELD TECHNICIAN. 6.CUT AND FILL SLOPES SHALL BE NO STEEPER THAN 2 FOOT HORIZONTAL TO 1 FOOT VERTICAL (2:1) EXCEPT WHERE SPECIFICALLY APPROVED OTHERWISE. 7.FILLS SHALL BE COMPACTED THROUGHOUT TO A MINIMUM OF 90% RELATIVE DENSITY. AGGREGATE BASE FOR ASPHALTIC AREAS SHALL BE COMPACTED TO MINIMUM OF 95% RELATIVE DENSITY. MAXIMUM DENSITY SHALL BE DETERMINED BY UNIFORM BUILDING CODE STANDARD NO. 70-1 OR APPROVED EQUIVALENT, AND FIELD DENSITY BY UNIFORM CODE STANDARD NO. 70-2 OR APPROVED EQUIVALENT. 8.THE CONTRACTOR SHALL NOT CREATE ANY TRENCH OR EXCAVATION 5-FEET OR MORE WITHOUT THE NECESSARY PERMIT FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY. 9.ALL CUT SLOPES SHALL BE INVESTIGATED BOTH DURING AND AFTER GRADING BY THE GEOTECHNICAL ENGINEER TO DETERMINE IF ANY SLOPE STABILITY PROBLEM EXISTS. SHOULD EXCAVATION DISCLOSE ANY GEOLOGICAL HAZARDS OR POTENTIAL GEOLOGICAL HAZARDS, THE GEOTECHNICAL ENGINEER SHALL SUBMIT A RECOMMENDED TREATMENT TO THE CITY ENGINEER FOR APPROVAL. 10.THE PERMITTEE IS RESPONSIBLE FOR DUST CONTROL MEASURES. WATER ACTIVE SITES AT LEAST TWICE DAILY. 11.THE LOCATING AND PROTECTION OF ALL EXISTING UTILITIES IS THE RESPONSIBILITY OF THE PERMITTEE. 12.GRADING OPERATIONS, INCLUDING MAINTENANCE OF EQUIPMENT, WITHIN ONE-HALF (1/2) MILE OF A STRUCTURE OF HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 8:00 P.M. AND 7:00 A.M. ON WEEKDAYS, INCLUDING SATURDAY, OR ANY TIME ON SUNDAY OR A FEDERAL HOLIDAY. (CITY OF SANTA ANA MUNICIPAL CODE SECTION 18-314) 13.THE PERMITTEE SHALL GIVE REASONABLE NOTICE TO THE OWNER OF ADJOINING LANDS AND BUILDINGS PRIOR TO BEGINNING EXCAVATIONS, WHICH MAY AFFECT THE LATERAL AND SUBJACENT SUPPORT OF THE ADJOINING PROPERTY. THE NOTICE SHALL STATE THE INTENDED DEPTH OF EXCAVATION AND WHEN EXCAVATION COMMENCES. THE ADJOINING OWNER SHALL BE ALLOWED AT LEAST 30 DAYS AND REASONABLE ACCESS ON THE PERMITTED PROPERTY TO PROTECT HIS STRUCTURE, IF HE SO DESIRES, UNLESS OTHERWISE PROTECTED BY LAW. 14.ALL EXISTING DRAINAGE COURSES THROUGH THE SITE SHALL REMAIN OPEN TO HANDLE THE STORM WATER; HOWEVER, IN ANY CASE, THE PERMITTEE SHALL BE HELD LIABLE FOR ANY DAMAGE DUE TO OBSTRUCTING NATURAL DRAINAGE PATTERNS. 15.APPROVED EROSION PROTECTION DEVICES SHALL BE PROVIDED AND MAINTAINED DURING THE RAINY SEASON AND SHALL BE IN PLACE AT THE END OF EACH DAY’S WORK. PROPER EROSION CONTROL MEASURES MUST BE SHOWN ON THE PLANS. 16.CONSTRUCTION SITES SHALL BE MAINTAINED IN SUCH A CONDITION THAT AN ANTICIPATED STORM DOES NOT CARRY WASTES OR POLLUTANTS OFF THE SITES. DISCHARGES OF MATERIAL OTHER THAN STORM WATER ARE ALLOWED ONLY WHEN NECESSARY FOR PERFORMANCE AND COMPLETION OF CONSTRUCTION PRACTICES AND WHERE THEY DO NOT: CAUSE OR CONTRIBUTE TO A VIOLATION OF ANY WATER QUALITY STANDARD; CAUSE OR THREATEN TO CAUSE POLLUTION, CONTAMINATION, OR NUISANCE; OR CONTAIN A HAZARDOUS SUBSTANCE IN A QUANTITY REPORTABLE UNDER FEDERAL REGULATIONS 40 CFR 117 AND 302. POTENTIAL POLLUTANTS INCLUDE BUT ARE NOT LIMITED TO: SOLID OR LIQUID CHEMICAL SPILLS; WASTES FROM PAINTS, STAINS, SEALANTS, GLUES, LIMES, PESTICIDES, HERBICIDES, WOOD PRESERVATIVES AND SOLVENTS; ASBESTOS FIBERS, PAINT FLAKES OR STUCCO FRAGMENTS; FUELS, OILS, LUBRICANTS, AND HYDRAULIC RADIATOR OR BATTERY FLUIDS; FERTILIZERS, VEHICLES/EQUIPMENT WASH WATER AND CONCRETE WASH WATER; CONCRETE, DETERGENT OR FLOATABLE WASTES; WASTES FROM ANY ENGINE/EQUIPMENT STEAM CLEANING OR CHEMICAL DEGREASING; AND SUPERCHLORINATED POTABLE WATER LINE FLUSHINGS. DURING CONSTRUCTION, DISPOSAL OF SUCH MATERIALS SHOULD OCCUR IN A SPECIFIED AND CONTROLLED TEMPORARY AREA ON-SITE, PHYSICALLY SEPARATED FROM POTENTIAL STORM WATER RUN-OFF, WITH ULTIMATE DISPOSAL IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REQUIREMENTS. 17.DEWATERING OF CONTAMINATED GROUNDWATER, OR DISCHARGING CONTAMINATED SOILS VIA SURFACE EROSION IS PROHIBITED. DEWATERING OF NON-CONTAMINATED GROUNDWATER REQUIRES A NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT FROM THE RESPECTIVE STATE REGIONAL WATER QUALITY CONTROL BOARD. 18.ALL DIRT, SAND, MUD, OR DEBRIS DEPOSITED OR SPILLED UPON PUBLIC STREETS DURING ANY GRADING, HAULING, OR EXPORT OPERATIONS SHALL BE IMMEDIATELY CLEANED UP BY THE DEVELOPER, HIS CONTRACTOR, SUBCONTRACTORS, OR AGENTS TO THE SATISFACTION OF THE CITY ENGINEER. FAILURE TO DO SO WILL BE CAUSE FOR STOPPING ALL SUCH GRADING, HAULING, OR EXPORT WORK BY THE CITY UNTIL SUCH TIME AS THE STREETS ARE CLEANED. 19.ALL TRUCKS HAULING DIRT, SAND, OIL, OR OTHER LOOSE MATERIALS ARE TO BE COVERED OR SHOULD MAINTAIN AT LEAST TWO FEET OF FREEBOARD IN ACCORDANCE WITH THE REQUIREMENTS OF CVC SECTION 23114. 20.CONTRACTOR IS RESPONSIBLE FOR THE REPAIR OF ALL DAMAGES TO PUBLIC PROPERTIES THAT ARE CAUSED BY THE WORK ON-SITE. REPAIR MUST BE COMPLETED TO THE SATISFACTION OF THE CITY ENGINEER. 21.MINIMUM ASPHALT PAVEMENT SECTIONS SHALL BE: • 3”AC/6”AB - PARKING AISLES • 4”AC/8”AB - DRIVES [COMMERCIAL] • 4”AC/12”AB - DRIVES [INDUSTRIAL] • 3” A.C. OVER 4” A.B. - PARKING STALLS [MULTI-FAMILY] • 3” A.C. OVER 8” A.B. - DRIVE AISLES [MULTI-FAMILY] 22.EARTHWORK VOLUMES: CUT 3.73 CUBIC YARDS FILL 8.15 CUBIC YARDS NET 4.43 CUBIC YARDS 23.IF THE NET VOLUMES EXCEED 500 CUBIC YARDS, THE CONTRACTOR MUST SUBMIT A HAUL TRUCK ROUTE TO THE CITY FOR APPROVAL. HAUL ROUTE SHALL INCLUDE THE LOCATION OF BORROW AND/OR DISPERSEMENT SITE, ALL STREETS INCLUDED IN THE ROUTE, THE PROPOSED STAGING AREA AND THE MAXIMUM GROSS WEIGHT OF THE TRUCKS WHEN LOADED. 24.SUBMIT AN 8 ½” X 11” HAUL ROUTE MAP OF APPROPRIATE SCALE WHICH INDICATES THE LOCATION OF THE PROJECT SITE, SHOWING STREETS AND DIRECTION OF HAULING UP TO AND INCLUDING THE END OF THE ROUTE. 25.PURSUANT TO ASSEMBLY BILL 3019, NO EXCAVATION PERMIT IS VALID UNLESS THE CONTRACTOR CONTACTS AND OBTAINS AN INQUIRY I.D. NUMBER FROM “UNDERGROUND SERVICE ALERT” (1-800-422-4133) AT LEAST TWO WORKING DAYS PRIOR TO COMMENCING EXCAVATION. 26.SEPARATE PERMITS MUST BE OBTAINED FROM THE CITY BUILDING AND SAFETY DIVISION FOR THE CONSTRUCTION OF RETAINING WALLS, LIGHT POLES, TRASH ENCLOSURES, ON-SITE PLUMBING AND ALL BUILDING STRUCTURES. 27.ALL FONTS ON PLANS SHOULD BE A MINIMUM OF 0.1”. OWNER: NARESH ARAYA EMAIL: Nkarya@gmail.com CONTACT: 949 400 5961 OWNER INFORMATION GENERAL GRADING NOTES: C-1.0 NOTICE TO PROCEED NTP1 25. 26. LEGEND: PARCEL 1. AS SHOWN ON A MAP FILED IN BOOK 38, PAGE 25 OF PARCEL MAPS, ORANGE COUNTY, CALIFORNIA. LEGAL DESCRIPTION ENLARGED SITE CONTROL PLANC-2.1 C-5.0 EROSION CONTROL PLAN C-5.1 EROSION CONTROL DETAILS Behrooz Sarlak 4/7/2025 (E) BUILDING FF = 108.90 8.50' 18 . 0 0 ' 9.00'8.00'9.00'8.50'8.50' 2 1 4 3 7 TYP 4 4 51.47'17.64' 8. 0 0 ' 7. 5 0 ' (E) BUILDING FF = 108.90' P P C L L L GR A N D A V E N U E N 0 0 ° 0 6 ' 2 0 ' ' W 66 0 . 0 1 ' (E) CC (E) AC (E) AC (E) AC (E) AC (E) PA (E) PA (E) PA (E) AC (E) AC(E) AC 38.60' (E) AC 5TYP5TYP5 6START 4. 0 0 ' 4 1 31 . 0 0 ' TYP 5 TYP 21 . 4 1 ' 9. 1 7 ' LIMIT OF WORK LIMIT OF WORK LIMIT OF WORK 3 TYP 10 . 0 7 ' 60.57'42.64' (E ) C O N C R E T E S I D E W A L K 70.08' 6 END 8 8 8 1 8 END6 8 8 6 69.75' 16.68' 9 9 1 CONSTRUCTION NOTES: CONSTRUCT NEW 4" THICK CONCRETE PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE PER DETAIL 1 ON SHEET C-4.0. CONSTRUCT NEW 4" THICK AC PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE (CAB) PER DETAIL 2 ON SHEET C-4.0. OVERLAY WITH NEW LAYERS OF AC PAVEMENT A MINIMUM OF 1.5" PER DETAIL 3 ON SHEET C-4.0. NEW STRIPING PER ARCHITECTURAL DRAWINGS. INSTALL NEW WHEEL STOP PER ARCHITECTURAL DRAWINGS. CONSTRUCT NEW 6" CONCRETE CURB PER DETAIL 4 ON SHEET C-4.0. INSTALL NEW CAST IN PLACE TRUNCATED DOMES PER DETAIL 7 ON SHEET C-4.0. CONSTRUCT CONCRETE CURB SLOT PER DETAIL 8 ON SHEET C-4.0. ACCESSIBLE SIGNAGE PER ARCHITECTURAL DRAWINGS. 2 3 4 5 6 7 8 9 CONSTRUCTION LEGEND: CONSTRUCT NEW 4" THICK CONCRETE PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE PER DETAIL 1 ON SHEET C-4.0. OVERLAY WITH NEW LAYERS OF AC PAVEMENT A MINIMUM OF 1.5" PER DETAIL 3 ON SHEET C-4.0. INSTALL NEW CAST IN PLACE TRUNCATED DOMES PER DETAIL 7 ON SHEET C-4.0. NEW STRIPING PER ARCHITECHTURAL DRAWINGS. LIMIT OF WORK CONSTRUCT NEW 4" THICK AC PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE PER DETAIL 2 ON SHEET C-4.0. 1.FOR GENERAL NOTES, LEGEND AND ABBREVIATIONS, SEE SHEET C-1.0. 2.SEE ARCHITECTURAL DRAWINGS FOR OTHER SITE RELATED DIMENSIONS NOT SHOWN ON THIS DRAWING. 3.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY SURFACE AND/ OR UNDERGROUND UTILITIES IN CONFLICT WITH THE PROPOSED DEMOLITION AND DESIGN ITEMS. CONTRACTOR SHALL REPORT ANY DISCREPANCIES AND/OR CONSTRUCTION RELATED ISSUES TO THE OWNER OR DESIGN TEAM PRIOR TO THE COMMENCEMENT OF WORK. 4.THE CONTRACTOR IS TO PROTECT THE EXISTING FOUNDATION DURING THE CONSTRUCTION OF THE SIDEWALK. SHEET NOTES: SCALE:1"=10' ENLARGE SITE CONTROL PLAN 0510 2000100 SURVEYOR'S INFORMATION: SURVEYOR DATE: JULY 15, 2024 FLORENTINO FERRER FERRER & ASSOCIATES LAND SURVEYORS & ENGINEERS 16388 COLIMA ROAD, UNIT 206-L HACIENDA HEIGHTS, CA 91745 SURVEYOR'S NOTES 1.THIS MAP REPRESENTS A TOPOGRAPHIC SURVEY OF VISIBLE FIELD CONDITIONS AT THE TIME OF THIS SURVEY. NO EASEMENTS, COVENANTS, CONDITIONS, OR RESTRICTIONS HAVE BEEN DETERMINED EXCEPT THOSE SHOWN. 2.THE HORIZONTAL BASIS FOR THIS SURVEY IS N 00°06'20" W GRAND AVENUE PER TRACT NO. 3841 SHEET 2 OF 2 IN THE CITY OF SANTA ANA, COUNTY OF ORANGE, STATE OF CALIFORNIA. 3.THE VERTICAL BASIS FOR THIS SURVEY IS DESCRIBED BY OCS 2001 - DISTURBED - FD 3 3 4" OCS ALUMINUM BM DISK STAMPED "3B-73-68", SET IN THE TOP OF THE N END OF A CONCRETE HEAD WALL. MONUMENT IS LOCATED IN THE NE CORNER OF THE INTERSECTION OF GRAND AVE AND THE SANTA FE/TOPEKA RAILWAY, 42.8' E'LY OF THE CENTERLINE OF GRAND AVE AND 51' N'LY OF THE MOST N'LY RAIL ALONG THE RAILWAY. MONUMENT IS SET LEVEL WITH THE SIDEWALK. ELEVATION = 116.36' 4.REFER TO AUTOCAD DWG FILE FOR ADDITIONAL SURVEY POINTS AND DATA FEATURES NOT SHOWN HERE. FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . SITE CONTROL PLAN 4 C-2.1 Behrooz Sarlak 4/7/2025 110.00' P P C (E) AC GR A N D A V E N U E N 0 0 ° 0 6 ' 2 0 ' ' W 66 0 . 0 1 ' L L (E) CC (E) AC (E) AC (E) AC (E) CC (E) AC (E) PA (E) PA (E) PA (E) AC (E) AC L (E) AC (E) AC (E) AC(E) AC (E) CC (E) BUILDING FF = 108.90 S 0 0 ° 0 1 ' 5 8 ' ' E CL E WAKEHAM AVE CL NORMANDY PL SCALE:1"=10' EXISTING CONDITIONS 0510 2000100 ABBREVIATIONS: AC ASPHALT CONCRETE BACK OF SIDEWALKBSW BS BLUE STRIPE CONCRETEC/CONC/CC CAR STOPCRS CONCRETE SLABCS DRAIN INLETDI DOUBLE WHITE STRIPEDWS EDGE OF CONCRETEEC EDGE OF PAVEMENTEP EDGE OF GUTTEREG ELECTRIC PULL BOXEPB FLOW LINEFL FIRE DEPARTMENT CONNECTIONFDCONN GROUNDGRD FINISH FLOORFF FIRE HYDRANTFH GRADE BREAKGB METAL COVERMC PULL BOXPB POST INDICATOR VALVEPIV ROOF DRAINRD TOP CURBTC TRUNCATED DOME PADTDP THRESHOLDTHR TRAFFIC SIGNAL PULL BOXTSPB WHITE STRIPEWS PROPERTY LINEPL CENTER LINECL LEGENDS: PALM TREE PULL BOX DRAIN INLET PIPE FIRE HYDRANT ROOF DRAIN CONTOUR LINE PROPERTY LINE CENTER LINE C L PILLAR/BUILDING PL POST INDICATOR VALVE FIRE DEPARTMENT CONNECTION ## - DIA IN INCHES SURVEYOR DATE: JULY 15, 2024 FLORENTINO FERRER FERRER & ASSOCIATES LAND SURVEYORS & ENGINEERS 16388 COLIMA ROAD, UNIT 206-L HACIENDA HEIGHTS, CA 91745 SURVEYOR'S NOTES 1.THIS MAP REPRESENTS A TOPOGRAPHIC SURVEY OF VISIBLE FIELD CONDITIONS AT THE TIME OF THIS SURVEY. NO EASEMENTS, COVENANTS, CONDITIONS, OR RESTRICTIONS HAVE BEEN DETERMINED EXCEPT THOSE SHOWN. 2.THE HORIZONTAL BASIS FOR THIS SURVEY IS N 00°06'20" W GRAND AVENUE PER TRACT NO. 3841 SHEET 2 OF 2 IN THE CITY OF SANTA ANA, COUNTY OF ORANGE, STATE OF CALIFORNIA. 3.THE VERTICAL BASIS (BENCHMARK) FOR THIS SURVEY IS DESCRIBED BY OCS 2001 - DISTURBED - FD 3 3 4" OCS ALUMINUM BM DISK STAMPED "3B-73-68", SET IN THE TOP OF THE N END OF A CONCRETE HEAD WALL. MONUMENT IS LOCATED IN THE NE CORNER OF THE INTERSECTION OF GRAND AVE AND THE SANTA FE/TOPEKA RAILWAY, 42.8' E'LY OF THE CENTERLINE OF GRAND AVE AND 51' N'LY OF THE MOST N'LY RAIL ALONG THE RAILWAY. MONUMENT IS SET LEVEL WITH THE SIDEWALK. ELEVATION = 116.36' 4.REFER TO AUTOCAD DWG FILE FOR ADDITIONAL SURVEY POINTS AND DATA FEATURES NOT SHOWN HERE. SURVEY INFORMATION: FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . EXISTING CONDITIONS 2 C-1.1 EXISTING DRAINAGE PATTERN/FLOW Behrooz Sarlak 4/7/2025 NOTES: A+ B M I N . 8" 1 1 1 1 A+ B M I N . 8" FACE OF WALL/ BLDG. 1/2" EXPANSION JOINT # 4 @ 12" O.C. # 4 @ 12" O.C. FLUSH WHEN ADJACENT TO HARDSCAPE. PROVIDE 1-1/2" DEPRESSION FOR LANDSCAPE AREA. EDGE CONDITION AT HARDSCAPE OR LANDSCAPE WHERE OCCURS PER PLAN A" B" EQ . EQ . FINISH SURFACE PER GRADING CONCRETE PAVEMENT #4 @ 12" O.C. CRUSHED AGGREGATE BASE @ 95% RELATIVE COMPACTION SCARIFY AND RECOMPACT TOP 12" OF SUBGRADE TO 90% RELATIVE COMPACTION EDGE CONDITION AT HARDSCAPE / LANDSCAPE EDGE CONDITION AT BLDG. FACE NOTES: 1/8" DE P T H = 1/ 4 S L A B TH I C K N E S S 12" MAX 1/8" DE P T H = 1/ 4 S L A B TH I C K N E S S LEGENDS: 1 2 1 3 1 7 3 5 1 7 6 4 3 0. 9 6 7 " 0. 7 2 2 " 0. 2 5 " NOTES: 0.90" AT BASE 0.45" AT TOP PLAN LOCATION THICKNESS THICKNESS NON-TRAFFIC 4" "A" 4" "B" PAVEMENT CONCRETE AGGREGATE BASE CRUSHED 1.CONCRETE, F'C = 2,500 PSI @ 28 DAYS. 2.REBARS, FY=60,000 PSI ASTM A615. 3.FOR WPJ CONSTRUCTION JOINTS AND PATTERN, REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS. 4.CRACK CONTROL JOINTS SHALL BE SPACED @ INTERVALS NOT GREATER THAN 10' USING SAWCUTS AND EXTEND MINIMUM OF 1/4 THE SLAB THICKNESS. 5.FOR FINISH SURFACES, COLOR INTEGRATION, EXPANSION JOINTS AND OTHER PAVEMENT SURFACE FEATURES, SEE ARCHITECTURAL & DRAWINGS. 6.FOR PAVEMENT TRANSITIONAL AND JOINT DETAILS REFER TO DETAIL 5 AND 6 ON THIS SHEET. 7.LANDSCAPE, TURF AND PLANTING AREA TO BE 1-1/2" BELOW ADJACENT CONCRETE PAVEMENT. 8.PROVIDE THICKENED EDGE FOR ALL EDGE CONDITIONS. SCARIFY AND RECOMPACT TOP 12" OF SUBGRADE TO 90% RELATIVE COMPACTION SCARIFY AND RECOMPACT TOP 12" OF SUBGRADE TO 90% RELATIVE COMPACTION 1.PROVIDE 1/4" EXPANSION JOINT WITH SELF-SEALING PREFORMED JOINT FILLER AT ALL ANGLE POINTS AND THE BEGINNING AND END OF ALL CURVES. 2.PROVIDE CONTRACTION JOINTS CONSISTING OF ONE INCH DEEP CUT SCORES AT 20' O.C. MAX. 3.WHERE A WALK IS ADJACENT TO THE CURB, THE JOINTS SHALL LINE WITH JOINTS IN THE WALK. 4.CONCRETE, F'C=3,000 PSI @ 28 DAYS. 5.REBARS, FY=60,000 PSI ASTM A615. 6.CONCRETE GUTTER IS A MODIFIED DETAIL OF CITY OF SANTA ANA STD. PLAN NO. 1101 DETAIL B-1 OR B-3. 1.PAVING FINISH SURFACE. 2.SAWCUT. 3.1/8" R. @ EDGES. TYP. 4.PREMOLDED E.J. FILLER. 5.JOINT SEALANT. COLOR TO BE SELECTED BY ARCHITECT. SUBMIT COLOR SAMPLES PRIOR TO INSTALLATION. 6.BACKER ROD. 7.18" #4 REBAR W/ 'SPEED DOWEL' @ 36" O.C., CENTER IN CONC. AT COLD JOINTS & E.J.'S. 8.EXPANSION JOINTS 20 O.C. MAX. COORDINATE WITH LANDSCAPE DRAWING FOR JOINT LOCATIONS. 9.CONTRACTOR TO SUBMIT SHOP DRAWINGS OF CONTROL JOINT AND EXPANSION JOINT LAYOUT. A: SAWCUT JOINT D: EXPANSION JOINTB: TOOLED JOINT C: COLD JOINT SURROUNDING PEDESTRIAN SURFACE DOME TILE TRUNCATED DOMES SHALL BE CAST IN PLACE REPLACEABLE TACTILE AND 33538 YELLOW 0.883" 1. ONLY APPROVED DSA-AC DETECTABLE WARNING PRODUCTS (TRUNCATED DOMES) AND DIRECTIONAL SURFACES SHALL BE INSTALLED AS PROVIDED IN THE CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 1, ARTICLES 2, 3 AND 4. REFER TO CCR TITLE 24, PART 12, CHAPTERS 12-11A AND B-102, FOR BUILDING AND FACILITY ACCESS SPECIFICATIONS FOR PRODUCT APPROVAL FOR DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACES. [CBC 11B-247.1] 2.REFER TO CITY OF SANTA ANA STANDARD PLAN NO. 1122 FOR ALL ADDITIONAL REQUIREMENTS AND DIMENTIONS RELATED TO TRUNCATED DOMES. 3.SEE MANUFACTURER'S (ADA SOLUTIONS, INC.) DRAWINGS AND SPECIFICATIONS FOR MORE DETAILS. 1. 7 0 " 1.70" P. O . T . TRUNCATED DOMES SHALL BE CAST IN PLACE REPLACEABLE TACTILE AND 33538 YELLOW OF SAE AMS-STD-595A. PANEL JOINT. DOME SPACING & PATTERN OF THE NEXT PANEL SHALL CONTINUE AT THE SAME SPACING TWO COATS OF SURFACE SEAL PER SPECIFICATIONS 1. 5 " ( M I N ) 1.5" MIN AC OVERLAY TO MEET NEW DESIGN GRADE PER GRADING PLANS PROVIDE TACK COAT BETWEEN (N) AND (E) AC PER APWA STANDARD SPECIFICATIONS SECTION 302-5.4 (2021 EDITION) GRIND 1.5" OF EXISTING AC PAVEMENT BEFORE OVERLAY OF NEW LAYERS NOTES: 1. FOR PAVEMENT TRANSITIONAL DETAIL REFER TO DETAIL 6 ON THIS SHEET. 2.AFTER AC OVERLAY, PAINT WITH SOLAR REFLECTIVE COATING PER ARCHITECTURAL DRAWINGS. 3. SEE SPEC 32.1236 FOR COATS OF SEAL SURFACE. 4. USE TACK COAT TYPE AR-4000 OR APPROVED EQUAL. APPLICATION RATE SHALL BE 0.05 GALLON / SQUARE YARD. SEE SECTION 302-5 OF THE STANDARD SPECIFICATIONS FOR TRACKING PROTECTION AND CLEAN-UP REQUIREMENTS. 5. CONTRACTOR SHALL EXERCISE CARE TO PREVENT THE TACK COAT FROM BEING APPLIED ON OTHER THAN THE AREA TO BE PAVED, AND SHALL BE RESPONSIBLE FOR REMOVING ANY TACK COAT FROM SURFACES NOT DESIGNATED TO BE PAVED AT NO COST TO THE OWNER. PAVEMENT TRANSITIONAL DETAIL6NOT TO SCALE CONCRETE PAVEMENT DETAIL1NOT TO SCALE ASPHALT PAVEMENT SECTION2NOT TO SCALE CAST IN PLACE TRUNCATED DOME DETAIL7NOT TO SCALE CONCRETE CURB DETAIL4NOT TO SCALE JOINT DETAIL5NOT TO SCALE NOTE: A B TABLE AC PAVEMENT SURFACING TYPE III, C3, PG-64-10 1.FOR PAVEMENT TRANSITION REFER TO DETAIL 6 ON THIS SHEET. SCARIFY AND RECOMPACT TOP 12" OF SUBGRADE TO 90% RELATIVE COMPACTION CRUSHED AGGREGATE BASE RECOMPACTED TO 95% RELATIVE COMPACTION TWO COATS OF SURFACE SEAL 3" GRADE C3 "A" BASE COURSE 6" LOCATION AC THICKNESS TYPE CAB FINE THICKNESSCLASS PARKING/LIGHT TRAFFIC "B" AC OVERLAY DETAIL3NOT TO SCALE EXIST AC PAVEMENT NEW CONSTRUCTION/ AC PAVEMENT EXIST BASENEW BASE 1'-0"REMOVE EXISTING AC AND REPLACE WITH NEW AC PAVEMENT EXISTING BASE COURSE EDGE NEATLY SAWCUTTACK COAT FULL DEPTH EXIST AC PAVEMENT NEW CC PAVEMENT EXIST BASENEW BASE EDGE NEATLY SAWCUTTACK COAT FULL DEPTH NEW BASE COURSE NEW BASE COURSE TYP. SECTION: 2-#4 CONT. BAR SCARIFY AND RECOMPACT TOP 12" OF SUBGRADE TO 90% RELATIVE COMPACTION EXIST LANDSCAPE AREA NEW CC PAVEMENT NEW BASE 1-1/2" DEPRESSION FOR LANDSCAPE AREA. TACK COAT FULL DEPTH NEW BASE COURSE FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . MISCELLANEOUS DETAIL TOP OF CURB FLOWLINE 6" 6" 12" 6"6" 12" 6" BOTTOM OF CURB TOP OF CURB CONCRETE CURB CONCRETE CURBCONCRETE CURB PAVEMENT PER SITE PLAN CURB SLOT DETAIL8NOT TO SCALE 6 C-4.0 CONCRETE PAVEMENT PER DETAIL 1 ON THIS SHEET OR LANDSCAPE WHERE OCCURS LANDSCAPE OR HARDSCAPE (SEE GRADING PLAN FOR ELEVATION) 6" M I N 8" M I N 3:12 BATTER TC ELEVATION PER GRADING PLAN ON SHEET C-3.0. FS ELEVATION PER GRADING PLAN ON SHEET C-3.0. R=1 2" TYP. 6" 2-#4 CONT. BAR SCARIFY AND RECOMPACT TOP 12" OF SUBGRADE TO 90% RELATIVE COMPACTION LANDSCAPE OR HARDSCAPE (SEE GRADING PLAN FOR ELEVATION) 3:12 BATTER TC ELEVATION PER GRADING PLAN ON SHEET C-3.0. FS ELEVATION PER GRADING PLAN ON SHEET C-3.0. R=1 2" TYP. 6" AC OVERLAY PER DETAIL 3 ON THIS SHEET CONCRETE CURB AT HARDSCAPE / LANDSCAPE CONCRETE CURB AT AC OVELAY Behrooz Sarlak 4/7/2025 IN CASE OF EMERGENCY, CALL: CONTRACTOR NAME ___________________________. PHONE NUMBER:_________________. A STAND-BY CREW FOR EMERGENCY WORK SHALL BE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (NOVEMBER 1 TO APRIL 15). NECESSARY MATERIALS SHALL BE AVAILABLE ON-SITE AND STOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF EMERGENCY DEVICES WHEN RAIN IS IMMINENT. EROSION CONTROL DEVICES SHOWN ON THIS PLAN MAY BE REMOVED WHEN APPROVED BY THE BUILDING OFFICIAL IF THE GRADING OPERATION HAS PROGRESSED TO THE POINT WHERE THEY ARE NO LONGER REQUIRED. GRADED AREAS ADJACENT TO FILL SLOPES LOCATED AT THE SITE PERIMETER MUST DRAIN AWAY FROM THE TOP OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY. ALL LOOSE SOILS AND DEBRIS THAT MAY CREATE A POTENTIAL HAZARD TO OFF-SITE PROPERTY SHALL BE STABILIZED OR REMOVED FROM THE SITE ON A DAILY BASIS. ALL SILT AND DEBRIS SHALL BE REMOVED FROM ALL DEVICES WITHIN 24 HOURS AFTER EACH RAINSTORM AND BE DISPOSED OF PROPERLY. A GUARD SHALL BE POSTED ON SITE WHEREVER THE DEPTH OF WATER IN ANY DEVICE EXCEEDS TWO FEET. THE DEVICE SHALL BE DRAINED OR PUMPED DRY WITHIN 24 HOURS AFTER EACH RAINSTORM. PUMPING AND DRAINING OF ALL BASINS AND DRAINAGE DEVICES MUST COMPLY WITH THE APPROPRIATE BMP FOR DEWATERING OPERATIONS. THE PLACEMENT OF ADDITIONAL DEVICES TO REDUCE EROSION DAMAGE AND CONTAIN POLLUTANTS WITHIN THE SITE IS LEFT TO THE DISCRETION OF THE QSP. ADDITIONAL DEVICES AS NEEDED SHALL BE INSTALLED TO RETAIN SEDIMENTS AND OTHER POLLUTANTS ON SITE. STORM WATER POLLUTION AND EROSION CONTROL DEVICES ARE TO BE MODIFIED, AS NEEDED, AS THE PROJECT PROGRESSES, THE DESIGN AND PLACEMENT OF THESE DEVICES IS THE RESPONSIBILITY OF THE FIELD ENGINEER. PLANS REPRESENTING CHANGES MUST BE SUBMITTED FOR APPROVAL IF REQUESTED BY THE BUILDING OFFICIAL. EVERY EFFORT MUST BE MADE TO ELIMINATE THE DISCHARGE OF NONSTORM WATER FROM THE PROJECT SITE AT ALL TIMES. ERODED SEDIMENTS AND OTHER POLLUTANTS MUST BE RETAINED ON-SITE AND MAY NOT BE TRANSPORTED FROM THE SITE VIA SHEET FLOW, SWALES, AREA DRAINS, NATURAL DRAINAGE COURSES, OR WIND. STOCKPILES OF EARTH AND OTHER CONSTRUCTION-RELATED MATERIALS MUST BE PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND OR WATER. FUELS, OILS, SOLVENTS, AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTINGS AND ARE NOT TO CONTAMINATE THE SOILS AND SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE SYSTEM. EXCESS OR WASTE CONCRETE MAY NOT BE WASTED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES ON-SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE. TRASH AND CONSTRUCTION-RELATED SOLID WASTES MUST BE DEPOSITED INTO A COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY. ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS. ANY SLOPES WITH DISTURBED SOILS OR DENUDED OF VEGETATION MUST BE STABILIZED SO AS TO INHIBIT EROSION BY WIND AND WATER. ALL WORK SHALL BE IN ACCORDANCE WITH THE EROSION CONTROL PLANS. EROSION CONTROL MEASURES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHENEVER THE DAILY RAINFALL PROBABILITY EXCEEDS 40%. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. NECESSARY MATERIALS SHALL BE AVAILABLE ON SITE AND STOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL DEVICES AT ALL TIME. CONTROLS SHALL BE SET UP AND MAINTAINED AS CONSTRUCTION PROCEEDS. ADJUSTMENTS TO THE EROSION CONTROL PLANS ARE ALLOWABLE AS REQUIRED AND APPROVED BY CITY. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL IMPLEMENT STRUCTURAL AND NONSTRUCTURAL BEST MANAGEMENT PRACTICES (BMPS) IN CONFORMANCE WITH THE GUIDELINES OF THE CALIFORNIA STORM WATER BMP HANDBOOKS. AFTER A RAINSTORM, ALL SEDIMENT AND DEBRIS SHALL BE REMOVED FROM STREETS, BERMS AND DESILTING BASINS. ANY GRADED SLOPE SURFACE PROTECTION MEASURES DAMAGED DURING A RAINSTORM SHALL BE IMMEDIATELY REPAIRED. THE PERMITTEE AND CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT TRESPASS ONTO AREAS WHERE IMPOUNDED WATER CREATED A HAZARDOUS CONDITION. EROSION AND SEDIMENT GENERAL NOTES: 12. 13. 10. 11. 7. 8. 9. 5. 6. 3. 4. 1. 2. EROSION CONTROL EC1 - SCHEDULING EC2 - PRESERVATION OF EXISTING VEGETATION EQUIPMENT TRACKING CONTROL TC1 - STABILIZED CONSTRUCTION ENTRANCE EXIT NON-STORMWATER MANAGEMENT NS2 - DEWATERING OPERATIONS NS3 - PAVING AND GRINDING OPERATIONS NS12 - CONCRETE CURING NS13 - CONCRETE FINISHING NS14 - MATERIAL AND EQUIPMENT USE TEMPORARY SEDIMENT CONTROL SE1 - SILT FENCE SE7 - STREET SWEEPING AND VACUUMING SE8 - GRAVEL BAG BARRIER WIND EROSION CONTROL WE1 - WIND EROSION CONTROL WASTE MANAGEMENT & MATERIAL POLLUTION CONTROL WM1 - MATERIAL DELIVERY AND STORAGE WM2 - MATERIAL USE WM3 - STOCKPILE MANAGEMENT WM5 - SOLID WASTE MANAGEMENT WM6 - HAZARDOUS WASTE MANAGEMENT WM8 - CONCRETE WASTE MANAGEMENT WM9 - SANITARY/SEPTIC WASTE MANAGEMENT WM10 - LIQUID WASTE MANAGEMENT 1.SOIL/SLOPE STABILIZATION PRACTICES SHALL BE DESIGNED TO PRESERVE EXISTING VEGETATION WHERE FEASIBLE AND TO REVEGETATE OPEN AREAS AS SOON AS FEASIBLE AFTER GRADING. THESE CONTROL PRACTICES SHALL INCLUDE TEMPORARY SEEDING, PERMANENT SEEDING, MULCHING, SOD STABILIZATION, VEGETATIVE BUFFER STRIPS, PROTECTION OF TREES, OR OTHER SOIL STABILIZATION PRACTICES. 2.SOIL STABILIZATION SHALL BE IMPLEMENTED ON ALL INACTIVE DISTURBED AREAS FROM NOVEMBER 1 THRU APRIL 15 AND ON ALL DISTURBED AREAS DURING A RAIN EVENT OR POTENTIAL RAIN. 3.STABILIZATION PRACTICES SHALL CONTROL/PREVENT EROSION FROM THE FORCES OF WIND AND WATER. 4.STABILIZATION PRACTICES SHALL BE IMPLEMENTED IN CONJUNCTION WITH SEDIMENT TRAPPING/FILTERING PRACTICES AND PRACTICES TO REDUCE THE TRACKING OF SEDIMENT ONTO PAVED ROADS. 5.WHEN USING STRAW MULCHING, THE MINIMUM APPLICATION SHALL BE 2 TONS/ACRE. MULCH MUST BE ANCHORED IMMEDIATELY TO MINIMIZE LOSS BY WIND OR WATER. 6.WHEN USING HYDROSEEDING/MULCHING, THE MINIMUM APPLICATION OF WOOD FIBER SHALL BE 1,500 LBS/ACRE,THAT DOES NOT CONTAIN MORE THAN 50 PERCENT NEWSPRINT. 7.FOR SEEDING RECOMMENDATIONS, USDA, NATURAL RESOURCES CONSERVATION SERVICE. NOTES: SEDIMENTS AND OTHER MATERIALS SHALL NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS SHALL BE STABILIZED SO AS TO PREVENT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC ROADS. DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS INTO THE STORM DRAIN SYSTEM. STABILIZED CONSTRUCTION ENTRANCE SHALL BE: A. LOCATED AT ANY POINT WHERE TRAFFIC WILL BE ENTERING OR LEAVING A CONSTRUCTION SITE RD OR FROM A PUBLIC RIGHT OF WAY, STREET, ALLEY, AND SIDEWALK OR PARKING AREA. B. A SERIES OF STEEL PLATES WITH "RUMBLE STRIPS", AND/OR MIN 4" COARSE AGGREGATE WITH LENGTH, WIDTH & THICKNESS AS NEEDED TO ADEQUATELY PREVENT ANY TRACKING ONTO PAVED SURFACES. ADDING A WASH RACK WITH A SEDIMENT TRAP LARGE ENOUGH TO COLLECT ALL WASH WATER CAN GREATLY IMPROVE EFFICIENCY. ALL VEHICLES ACCESSING THE CONSTRUCTION SITE SHALL UTILIZE THE STABILIZED CONSTRUCTION ENTRANCE SITES. REMOVE ALL SEDIMENT DEPOSITED ON PAVED ROADWAYS IMMEDIATELY. SWEEP PAVED AREAS THAT RECEIVE CONSTRUCTION TRAFFIC WHENEVER SEDIMENT BECOMES VISIBLE. PAVEMENT WASHING WITH WATER IS PROHIBITED IF IT RESULTS IN A DISCHARGE TO THE STORM DRAIN SYSTEM. REGULAR SWEEPING SCHEDULES SHALL BE SET UP, PARTICULARLY AFTER HEAVY RAINFALL OR CONSTRUCTION ACTIVITIES, TO ADDRESS VISIBLE DEBRIS AND ENSURE THE ROADWAYS REMAIN CLEAR OF CONTAMINANTS. VACUUM SWEEPERS, IN PARTICULAR, ARE HIGHLY EFFECTIVE AT COLLECTING FINE DUST AND PARTICLES THAT ARE HARDER TO CAPTURE WITH TRADITIONAL MECHANICAL SWEEPERS. STREET MAINTENANCE CONSTRUCT THE SILT FENCE ALONG A LEVEL CONTOUR. SILT FENCES SHALL REMAIN IN PLACE UNTIL THE DISTURBED AREA IS PERMANENTLY STABILIZED. PROVIDE SUFFICIENT ROOM FOR RUNOFF TO POND BEHIND THE FENCE AND ALLOW SEDIMENT REMOVAL EQUIPMENT TO PASS BETWEEN THE SILT FENCE AND TOE OF SLOPE OR OTHER OBSTRUCTIONS. ABOUT 1200 SQ. FT. OF PONDING AREA SHALL BE PROVIDED FOR EVERY ACRE DRAINING TO THE FENCE. TURN THE ENDS OF THE FILTER FENCE UPHILL TO PREVENT STORMWATER FROM FLOWING AROUND THE FENCE. LEAVE AN UNDISTURBED OR STABILIZED AREA IMMEDIATELY DOWNSLOPE FROM THE FENCE. DO NOT PLACE IN LIVE STREAM OR INTERMITTENTLY FLOWING CHANNELS. WHEN STANDARD FILTER FABRIC IS USED, A WIRE MESH SUPPORT FENCE SHALL BE FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS USING HEAVY-DUTY WIRE STAPLES AT LEAST 1 INCH LONG. TIE WIRES OR HOG RINGS. NOTES: SILT FENCE MAXIMUM SLOPE LENGTH COMPACTED BACKFILL TURN LOST 6' OF FENCE UP-SLOPE MAXIM U M WIDTH = 5 0 0 ' 6" 6" 18 " MAXIMUM TRIBUTARY AREA .25 ACRE/100FT OF FENCE SILT FENCE CONSTRUCTED ALONG LEVEL CONTOUR POST O 10" OC (MAX) 1. FLOW FILTER FABRIC 1. 2. 3. 4. 3 EROSION CONTROL 4 STABILIZED CONSTRUCTION ENTRANCE / EXIT PER TC-1 14. 15. 16. 17. 18. 19. 30 1. 2. 3. DIRT AND OTHER CONSTRUCTION RELATED MATERIALS PLACED IN THE STREET OR ON OTHER IMPERVIOUS SURFACES MUST BE CONTAINED WITH SANDBAGS OR OTHER MEASURES TO PREVENT TRANSPORT TO THE STORMDRAIN SYSTEM. ANY CONSTRUCTION MATERIAL STORED OR STOCKPILED ON-SITE SHALL BE PROTECTED FROM BEING TRANSPORTED BY THE FORCE OF WIND OR WATER. GRAVEL BAGS PLACE TIGHTLY TOGETHER ALL AROUND MATERIAL 1. 2. NOTES: STOCKPILED MATERIAL AS THE PROJECT OWNER OR AUTHORIZED AGENT OF THE OWNER, I HAVE READ AND UNDERSTAND THE REQUIREMENTS TO CONTROL STORM WATER POLLUTION FROM SEDIMENTS, EROSION, AND CONSTRUCTION MATERIALS, AND I CERTIFY THAT I WILL COMPLY WITH THESE REQUIREMENTS. I, OR MY REPRESENTATIVE, CONTRACTOR, DEVELOPER, OR ENGINEER, WILL MAKE CERTAIN THAT ALL BMP'S SHOWN ON THIS PLAN WILL BE FULLY IMPLEMENTED, AND ALL EROSION CONTROL DEVICES WILL BE KEPT CLEAN AND FUNCTIONING. PERIODIC INSPECTIONS OF THE BMPs WILL BE CONDUCTED AND A CURRENT LOG, SPECIFYING THE EXACT NATURE OF THE INSPECTION AND ANY REMEDIAL MEASURES, WILL BE KEPT AT THE CONSTRUCTION SITE AT ALL TIMES AND WILL BE AVAILABLE FOR THE REVIEW BY THE BUILDING OFFICIAL. AS THE PROJECT OWNER OR AUTHORIZED AGENT OF THE OWNER, "I CERTIFY THAT THIS DOCUMENT AND ALL ATTACHMENTS WERE PREPARED UNDER MY DIRECTION OR SUPERVISION IN ACCORDANCE WITH A SYSTEM DESIGNED TO ASSURE THAT QUALIFIED PERSONNEL PROPERLY GATHER AND EVALUATE THE INFORMATION SUBMITTED. BASED ON MY INQUIRY OF THE PERSON OR PERSONS WHO MANAGE THE SYSTEM OR THOSE PERSONS DIRECTLY RESPONSIBLE FOR GATHERING THE INFORMATION, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE INFORMATION SUBMITTED IS TRUE, ACCURATE, AND COMPLETE. I AM AWARE THAT SUBMITTING FALSE AND/OR INACCURATE INFORMATION, FAILING TO UPDATE THE LOCAL SWPPP TO REFLECT CURRENT CONDITIONS, OR FAILING TO PROPERLY AND/OR ADEQUATELY IMPLEMENT THE LOCAL SWPPP MAY RESULT IN REVOCATION OF GRADING AND/OR OTHER PERMITS OR OTHER SANCTIONS PROVIDED BY THE LAW." OWNER OR AUTHORIZED REPRESENTATIVE (PERMITEE) DATE OWNER STATEMENT OF UNDERSTANDING: STATEMENT OF UNDERSTANDING NOTES: 2. 3. 4. 5. 6. 7. 7 COMPACTED BACKFILL NOT TO SCALE NOT TO SCALE MATERIAL STORAGE PER WM-3 NOT TO SCALE5 6 SILT FENCE PER SE-1 NOT TO SCALE 2 GRAVEL BAG DETAIL NOT TO SCALE A SECTION A-A A 3" MIN OPENING BETWEEN TOP ROW BAGS 20. 21. 22. 4. FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . EROSION CONTROL PLAN 8 NARESH ARAYA 11/26/2024 C-5.1 HANK (ALL STAR PAVING CO.) (714) 835-9177 Behrooz Sarlak 4/7/2025 1.FOR GENERAL NOTES, LEGEND AND ABBREVIATIONS, SEE SHEET C-1.0. 2.SEE ARCHITECTURAL DRAWINGS FOR OTHER SITE RELATED DIMENSIONS NOT SHOWN ON THIS DRAWING. 3.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY SURFACE AND/ OR UNDERGROUND UTILITIES IN CONFLICT WITH THE PROPOSED DEMOLITION AND DESIGN ITEMS. CONTRACTOR SHALL REPORT ANY DISCREPANCIES AND/OR CONSTRUCTION RELATED ISSUES TO THE OWNER OR DESIGN TEAM PRIOR TO THE COMMENCEMENT OF WORK. 4.THE CONTRACTOR IS TO PROTECT THE EXISTING FOUNDATION DURING THE CONSTRUCTION OF THE SIDEWALK. SHEET NOTES: CONSTRUCTION LEGEND: CONSTRUCT NEW 4" THICK CONCRETE PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE PER DETAIL 1 ON SHEET C-4.0. OVERLAY WITH NEW LAYERS OF AC PAVEMENT A MINIMUM OF 1.5" PER DETAIL 3 ON SHEET C-4.0. INSTALL NEW CAST IN PLACE TRUNCATED DOMES PER DETAIL 7 ON SHEET C-4.0. NEW STRIPING PER ARCHITECHTURAL DRAWINGS. LIMIT OF WORK CONSTRUCT NEW 4" THICK AC PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE PER DETAIL 2 ON SHEET C-4.0. (E) BUILDING FF = 108.90 (E) BUILDING FF = 108.90' (E) BUILDING FF = 108.90' (E) AC (E) AC (E) AC (E) PA (E) PA (E) AC (E) PA (E) PA LP LC GR A N D A V E N U E N 0 0 ° 0 6 ' 2 0 ' ' W 6 6 0 . 0 1 ' (E ) CO N C R E T E S I D E W A L K (E) AC (E) AC SCALE:1"=20' OVERALL SITE CONTROL PLAN 0510 2000100 FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . OVERALL SITE CONTROL PLAN 4 C-2.0 SEE ENLARGED PLAN ON SHEET C-2.1 Behrooz Sarlak 4/7/2025 SHEET NO.DESCRIPTION CD-1.0 GENERAL NOTES, LEGENDS, AND ABBREVIATIONS SITE DEMOLITION PLAN SHEET INDEX: C-1.0 EXISTING CONDITIONSC-1.1 CONSTRUCTION LEGEND: ABBREVIATIONS: AC ASPHALT CONCRETE BACK OF SIDEWALKBSW OVERALL SITE CONTROL PLANC-2.0 SITE GRADING PLAN AND SECTIONSC-3.0 C-4.0 VICINITY MAP NOT TO SCALE MISCELLANEOUS DETAILS BS BLUE STRIPE CONCRETEC/CONC/CC CAR STOPCRS CONCRETE SLABCS DRAIN INLETDI DOUBLE WHITE STRIPEDWS EDGE OF CONCRETEEC EDGE OF PAVEMENTEP EDGE OF GUTTEREG ELECTRIC PULL BOXEPB FLOW LINEFL FIRE DEPARTMENT CONNECTIONFDCONN GROUNDGRD FINISH FLOORFF FIRE HYDRANTFH GRADE BREAKGB METAL COVERMC PULL BOXPB POST INDICATOR VALVEPIV ROOF DRAINRD TOP CURBTC TRUNCATED DOME PADTDP THRESHOLDTHR TRAFFIC SIGNAL PULL BOXTSPB WHITE STRIPEWS PROPERTY LINEPL CENTER LINECL E WAKEHAM AVE E HUNTER AVE NORMANDY PL S G R A N D A V E PROJECT SITE GENERAL NOTES: ALL WORK PERFORMED IN THIS CONTRACT SHALL CONFORM TO: A.PROJECT SPECIFICATIONS. B.ALL SHALL CONFORM TO THE LATEST EDITION AND SUPPLEMENTS OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (SSPWC) AND AMERICAN PUBLIC WORKS ASSOCIATION (APWA). C.2022 CALIFORNIA BUILDING CODE. D.CITY OF SANTA ANA PUBLIC WORKS STANDARD PLANS. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE WORK SPECIFIED ON THE DRAWINGS AND WITHIN THE VARIOUS NOTES SHOWN HEREIN. THE EXISTING CONDITIONS SHOWN DIAGRAMMATICALLY ON THE PLANS ORIGINATED FROM AS-BUILT DRAWINGS AND FIELD SURVEY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE AND VERIFY THE EXACT EXISTING CONDITIONS UNLESS CONCEALED BEFORE SUBMITTING HIS BID. ANY DISCREPANCY SHALL BE REPORTED IMMEDIATELY TO THE OWNER USING THE PROPER REQUEST FOR INFORMATION FORMS PRIOR TO SUBMITTING HIS BID FOR PROPER ACTION. THE CONTRACTOR SHALL PROTECT ALL EXISTING STRUCTURES IN THE AREA OF WORK WHICH ARE NOT INCLUDED IN THIS CONSTRUCTION. ANY DAMAGE RESULTING FROM THIS WORK SHALL BE REPAIRED AND/OR REPLACED AT NO ADDITIONAL COST TO THE OWNER. UNDERGROUND SERVICE ALERT: BEFORE COMMENCING ANY EXCAVATION, THE CONTRACTOR SHALL OBTAIN AN UNDERGROUND SERVICE ALERT INQUIRY I.D. NUMBER BY CALLING 1-800-422-4133. TWO (2) WORKING DAYS SHALL BE ALLOWED AFTER THE I.D. NUMBER IS OBTAINED AND BEFORE THE EXCAVATION WORK IS STARTED THAT UTILITY OWNERS CAN BE NOTIFIED. PROTECTION AND RESTORATION OF EXISTING IMPROVEMENTS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF PUBLIC AND PRIVATE PROPERTY ADJACENT TO THE WORK PER SECTION 7-9 OF THE STANDARD SPECIFICATIONS. REMOVALS: ALL SITE PREPARATION AS INDICATED SHALL BE MADE UNDER THE CONTINUOUS INSPECTION OF THE INSPECTOR OF RECORD (IOR) AND OWNER AUTHORIZED REPRESENTATIVE (OAR). SECURE THE REQUIRED PERMIT FROM THE CALIFORNIA DIVISION OF INDUSTRIAL SAFETY FOR THE CONSTRUCTION OF TRENCHES, SHORING OR EXCAVATIONS WHICH ARE 5 FEET OR DEEPER OR WORK THAT MAY JEOPARDIZE THE WORKERS. SHORING CALCULATIONS SHALL BE PROVIDED AS REQUIRED FOR APPROVAL AND PERMITTING. THE CONTRACTOR SHALL KEEP THE CONSTRUCTION AREA SUFFICIENTLY DAMPENED TO CONTROL DUST CAUSED BY WORK ACTIVITIES AS REQUIRED BY THE JURISDICTIONAL AGENCY. ALL FILL OR BACKFILL SHALL BE COMPACTED TO AT LEAST 90% MDD (MAXIMUM DRY DENSITY) PER ASTM D-1557. CONSTRUCTION STAKING AND ADJUSTMENTS FOR IMPROVEMENTS SHOWN ON THESE PLANS SHALL BE PERFORMED BY A LICENSED LAND SURVEYOR PAID FOR BY THE CONTRACTOR AND INCLUDED IN THE CONTRACT. VOIDS RESULTING FROM REMOVAL WORK SHALL BE FILLED WITH SUITABLE MATERIALS COMPACTED TO 90% MAXIMUM DENSITY PER ASTM D-1557. IF EXISTING UTILITIES ARE EXPOSED OR DETERMINED TO EXIST UNDER THE CONSTRUCTION LIMITS, CONTRACTOR SHALL PROVIDE A FLAGGED STAKE THAT INDICATES THEIR LOCATION, TYPE OF UTILITY, SIZE, PIPE MATERIAL AND DEPTH. STAKES SHALL BE INSTALLED NO LESS THAN 50' ON CENTER ON STRAIGHT LINES AND AT BENDS. MAINTAIN A RECORD OF LOCATION OF UTILITY MARKERS ON THE AS-BUILT PLAN AND REINSTALL THEM AFTER PAVING. REPLACE BENT OR UNUSABLE MARKERS FOR ALL UTILITY LINES DISCOVERED WITHIN THE WORK AREA. INSTALL BRASS UTILITY MARKERS INDICATING DIRECTIONS OF LINES AT ALL CHANGES IN DIRECTIONS AFTER PAVING. INFORM THE SURVEYOR TO LOCATE AND RECORD ACTUAL LOCATIONS. UNCLOG, CLEAN AND FLUSH THE WORK AREA DRAINAGE SYSTEM AFTER PAVING AND IMMEDIATELY BEFORE A RAIN FORECAST. CALIFORNIA PUBLIC RESOURCES CODE (SECTION 5097.98) AND HEALTH AND SAFETY CODE (SECTION 7050.5) ADDRESS THE DISCOVERY AND DISPOSITION OF HUMAN REMAINS. IN THE EVENT OF DISCOVERY OR RECOGNITION OF ANY HUMAN REMAINS IN ANY LOCATION OTHER THAN A DEDICATED CEMETERY, THE LAW REQUIRES THAT GRADING IMMEDIATELY STOPS AND NO FURTHER EXCAVATION OF DISTURBANCE OF THE SITE, OR ANY NEARBY AREA WHERE HUMAN REMAINS MAY BE LOCATED, OCCUR UNTIL THE FOLLOWING MEASURES HAVE BEEN TAKEN: A.IF THE REMAINS ARE OF NATIVE AMERICAN ORIGIN, THE DESCENDANTS FROM THE DECEASED NATIVE AMERICANS HAVE MADE A RECOMMENDATION FOR THE MEANS OF TREATING OR DISPOSING, WITH APPROPRIATE DIGNITY, OF THE HUMAN REMAINS AND ANY ASSOCIATED GRAVE GOODS. B.IF THE REMAINS ARE OF NATIVE AMERICAN ORIGIN, THE DESCENDANTS FROM THE DECEASED NATIVE AMERICANS HAVE MADE A RECOMMENDATION FOR THE MEANS OF TREATING OR DISPOSING, WITH APPROPRIATE DIGNITY, OF THE HUMAN REMAINS AND ANY ASSOCIATED GRAVE GOODS. ALL EXPORT OF MATERIAL FROM THE SITE MUST GO TO A PERMITTED SITE APPROVED BY INSPECTOR OF RECORD OR A LEGAL DUMPSITE. RECEIPTS FOR ACCEPTANCE OF EXCESS MATERIAL BY A DUMPSITE ARE REQUIRED AND MUST BE PROVIDED TO THE INSPECTOR OF RECORD UPON REQUEST. ANY ADDITIONAL SURVEYS OR TESTING AS A RESULT OF CONTRACTOR ERROR OR MISINFORMATION WILL BE CHARGED TO THE CONTRACTOR. SITE BOUNDARIES, EASEMENTS, DRAINAGE DEVICES, RESTRICTED USE AREAS SHALL BE LOCATED PER CONSTRUCTION STAKING BY A LICENSED SURVEYOR. PRIOR TO GRADING, AS REQUESTED BY THE INSPECTOR OF RECORD, ALL PROPERTY LINES, EASEMENTS, AND RESTRICTED USE AREAS SHALL BE STAKED. A COPY OF THE APPROVED GRADING PLANS MUST BE IN THE POSSESSION OF A RESPONSIBLE PERSON AND AVAILABLE AT THE SITE AT ALL TIMES. CONTRACTOR SHALL INSTALL TEMPORARY FENCING AROUND THE PERIMETER OF THE CONSTRUCTION SITE AND STAGING AREA. FENCING SHALL BE MINIMUM 6 FEET TALL AND SHALL HAVE A DUST/VISION BARRIER ALONG THE FULL LENGTH. THE DUST/VISION BARRIER SHALL EXTEND THE LENGTH OF THE CONSTRUCTION SITE. THE FENCING SHALL BE ANCHORED TO THE SURFACE AND SHALL BE ABLE TO WITHSTAND A 200-POUND HORIZONTAL POINT LOAD IN ANY DIRECTION. TEMPORARY FENCING POLES AND GATES POST SHALL BE DRIVEN INTO THE GROUND. FENCE STANDS WILL NOT BE ALLOWED EXCEPT FOR AREAS WHERE EXISTING CONCRETE IS TO REMAIN PROTECT IN PLACE. WORK AREA AND STAGING AREA SHALL BE SECURE AT ALL TIMES. THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY, AND SHALL NOT BE LIMITED TO NORMAL WORKING HOURS. THE PROPOSED GRADE IS THE FINAL GRADE AND NOT THE ROUGH GRADE. THE CONTRACTOR SHALL SUBTRACT THE THICKNESS OF THE PAVED SECTION AND/OR LANDSCAPE TOPSOIL SECTION TO ARRIVE AT THE ROUGH GRADE ELEVATION. CONSTRUCT STRAIGHT GRADES BETWEEN ELEVATIONS SHOWN ON PLAN UNLESS INTERRUPTED BY A GRADE CHANGE LINE. ANY DEVIATION FROM THE GRADING PLAN MUST HAVE PRIOR APPROVAL FROM THE ENGINEER OF RECORD. GRADE LAWN, TURF, AND PLANTING AREA 1-1/2" MAX AT ACCESSIBLE PATH OF TRAVEL AND 2" MAX AT OTHER AREAS BELOW DESIGN GRADES INDICATED. THE CONTRACTOR SHALL CONTACT DIG ALERT BY DIALING 811 AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION TO NOTIFY UTILITY OWNERS. HAND DIG ONLY AT LOCATION WHERE UNDERGROUND UTILITIES NEED TO BE PROTECTED IN PLACE. 8. 7. 6. 5. 4. 3. 2. 1. 9. 10. 11. 12. 13. 14. 15. 16. 18. 17. 19. 20. 21. 22. 24. 23. PALM TREE PULL BOX DRAIN INLET PIPE FIRE HYDRANT ROOF DRAIN CONTOUR LINE PROPERTY LINE CENTER LINE C L PILLAR/BUILDING PL POST INDICATOR VALVE FIRE DEPARTMENT CONNECTION # # - DIA IN INCHES CONSTRUCT NEW 4" THICK CONCRETE PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE PER DETAIL 1 ON SHEET C-4.0. CONSTRUCT NEW 4" THICK PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE (CAB) PER DETAIL 2 ON SHEET C-4.0. INSTALL NEW CAST IN PLACE TRUNCATED DOMES PER DETAIL 7 ON SHEET C-4.0 NEW STRIPING PER ARCHITECTURAL DRAWINGS. REMOVE EXISTING AC PAVEMENT AND BASE MATERIAL, FULL DEPTH. REMOVE EXISTING CONCRETE PAVEMENT AND BASE MATERIAL, FULL DEPTH. GRIND 1.5" OF EXISTING AC PAVEMENT IN PREPARATION OF AC OVERLAY PER DETAIL 3 ON SHEET C-4.0. CLEAR, GRUB, AND REMOVE EXISTING GRASS/PLANTER/BUSH/ GRAVEL EXPOSED SUBGRADE AREA. REMOVE EXISTING SHRUBS AND ROOTS IN ITS ENTIRETY. LIMIT OF WORK ------------------------------------------------------------------------ LIMIT OF REMOVAL ------------------------------------------------------------------- OVERLAY WITH NEW LAYERS OF AC PAVEMENT A MINIMUM OF 1.5" PER DETAIL 3 ON SHEET C-4.0. SURVEYOR DATE: JULY 15, 2024 FLORENTINO FERRER FERRER & ASSOCIATES LAND SURVEYORS & ENGINEERS 16388 COLIMA ROAD, UNIT 206-L HACIENDA HEIGHTS, CA 91745 APN NUMBER 402-322-01 SURVEYOR'S NOTES 1.THIS MAP REPRESENTS A TOPOGRAPHIC SURVEY OF VISIBLE FIELD CONDITIONS AT THE TIME OF THIS SURVEY. NO EASEMENTS, COVENANTS, CONDITIONS, OR RESTRICTIONS HAVE BEEN DETERMINED EXCEPT THOSE SHOWN. 2.THE HORIZONTAL BASIS FOR THIS SURVEY IS N 00°06'20" W GRAND AVENUE PER TRACT NO. 3841 SHEET 2 OF 2 IN THE CITY OF SANTA ANA, COUNTY OF ORANGE, STATE OF CALIFORNIA. 3.THE VERTICAL BASIS (BENCHMARK) FOR THIS SURVEY IS DESCRIBED BY OCS 2001 - DISTURBED - FD 3 3 4" OCS ALUMINUM BM DISK STAMPED "3B-73-68", SET IN THE TOP OF THE N END OF A CONCRETE HEAD WALL. MONUMENT IS LOCATED IN THE NE CORNER OF THE INTERSECTION OF GRAND AVE AND THE SANTA FE/TOPEKA RAILWAY, 42.8' E'LY OF THE CENTERLINE OF GRAND AVE AND 51' N'LY OF THE MOST N'LY RAIL ALONG THE RAILWAY. MONUMENT IS SET LEVEL WITH THE SIDEWALK. ELEVATION = 116.36' 4.REFER TO AUTOCAD DWG FILE FOR ADDITIONAL SURVEY POINTS AND DATA FEATURES NOT SHOWN HERE. SURVEY INFORMATION: FS FG FINISHED SURFACE FINISHED GRADE REMOVAL LEGEND: CONCRETEC/CONC/CC CONCRETEC/CONC/CC CONCRETEC/CONC/CC CONCRETEC/CONC/CC CONCRETEC/CONC/CC CRUSHED AGGREGATE BASECAB PLANTER AREAPA MAXIMUM DRY DENSITYMDD 1.THE ESTIMATED QUANTITIES PROVIDED ABOVE ARE FOR REFERENCE ONLY TO BE USED FOR JURISDICTIONAL PLAN CHECKING AND PERMITTING PURPOSES ONLY. 2.ESTIMATED EARTHWORK ABOVE IS BASED ON DESIGN FINISH GRADES TO EXISTING GRADES IN SURVEY. THE ESTIMATED EARTHWORK DOES NOT CONSIDER THE THICKNESS OF EACH PAVEMENT MATERIAL, FOUNDATION AND SLAB ON GRADE VOLUMES, THE REMOVAL OF ANY UNSUITABLE MATERIAL, AND THE REMOVAL OF EXISTING BASEMENTS, PITS, VAULTS, TOP SOIL OR VEGETATION. 3.THE ESTIMATED EARTHWORK QUANTITIES DO NOT INCLUDE SHRINKAGE FACTORS DUE TO COMPACTION OR ANY OVER EXCAVATION QUANTITIES. 4.ESTIMATED EARTHWORK QUANTITIES ABOVE ASSUME THAT ALL ON-SITE MATERIALS ARE SUITABLE FOR BACKFILLING. HOWEVER, ACTUAL EXISTING ON-SITE MATERIALS AND IMPORTED MATERIALS MUST FIRST BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO INSTALLATION, REMOVAL, OR REPLACEMENT. 5.INFORMATION SHOWN WITHIN THE CONSTRUCTION DOCUMENTS WAS DERIVED FROM AS-BUILT PLANS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THE CONSTRUCTION DOCUMENTS. IF ANY DISCREPANCIES ARISE, CONTRACTOR SHALL INFORM OWNER AND DESIGN TEAM. ESTIMATED EARTHWORK QUANTITY NOTES: ESTIMATED CUT = 3.73 CU YD ESTIMATED FILL = 8.15 CU YD ESTIMATED NET = 4.43 CU YD (FILL) REMOVE EXISTING TRUNCATED DOME IN ITS ENTIRETY. FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . GENERAL NOTES, LEGENDS, AND ABBREVIATIONS Underground Service Alert of Southern California Know what's below. before you dig.Call R 1 UTILITY WATER PURVEYOR CITY IF SANTA ANA WATER DIVISION COSTUMER SERVICE: 714 647 5000 EMAIL: water@santa-ana.org WEBSITE: www.santa-ana.org/water UTILITY SEWER PURVEYOR CITY IF SANTA ANA PUBLIC WORKS AGENCY COSTUMER SERVICE: 714 647 3380 EMAIL:publicworks@santa-ana.org WEBSITE: www.santa-ana.org/publicworks UTILITY STORM DRAIN PURVEYOR CITY IF SANTA ANA PUBLIC WORKS AGENCY COSTUMER SERVICE: 714 647 3380 EMAIL:publicworks@santa-ana.org WEBSITE: www.santa-ana.org UTILITY INFORMATION 1.ALL GRADING SHALL COMPLY WITH THE LATEST CBC CHAPTERS 18 AND 33, AND APPENDIX J AND THE SANTA ANA MUNICIPAL CODE. A CITY GRADING PERMIT IS REQUIRED FOR GRADING. 2.GRADING SHALL NOT BE STARTED WITHOUT FIRST NOTIFYING THE CITY GRADING INSPECTOR. A PRE-GRADING MEETING ON THE SITE IS REQUIRED BEFORE STARTING OF GRADING WITH THE FOLLOWING PEOPLE PRESENT: GRADING CONTRACTOR, DESIGN CIVIL ENGINEER, GEOTECHNICAL ENGINEER, GRADING INSPECTOR AND WHEN REQUIRED, THE ARCHAEOLOGIST AND PALEONTOLOGIST. THE REQUIRED INSPECTIONS FOR GRADING WILL BE EXPLAINED AT THIS MEETING. 3.AN APPROVED COPY OF THE GRADING PLANS SHALL BE ON THE PERMITTED SITE WHILE WORK IS IN PROGRESS. 4.THE DESIGN CIVIL ENGINEER SHALL BE AVAILABLE DURING THE GRADING TO VERIFY COMPLIANCE WITH THE PLANS, SPECIFICATIONS, CODE AND ANY SPECIAL CONDITIONS OF THE PERMIT WITHIN HIS PURVIEW. 5.THE GEOTECHNICAL ENGINEER SHALL PERFORM PERIODIC INSPECTIONS AND SUBMIT A COMPLETE REPORT AND MAP UPON COMPLETION OF THE ROUGH GRADING. THE COMPACTION REPORT AND APPROVAL FROM THE GEOTECHNICAL ENGINEER SHALL INDICATE THE TYPE OF FIELD TESTING PERFORMED. EACH TEST SHALL BE IDENTIFIED WITH THE METHOD OF OBTAINING THE IN-PLACE DENSITY, WHETHER SAND CONE OR DRIVE RING, AND SHALL BE SO NOTED FOR EACH TEST. SUFFICIENT MAXIMUM DENSITY DETERMINATIONS SHALL BE PERFORMED TO VERIFY THE ACCURACY OF THE MAXIMUM DENSITY CURVES BY THE FIELD TECHNICIAN. 6.CUT AND FILL SLOPES SHALL BE NO STEEPER THAN 2 FOOT HORIZONTAL TO 1 FOOT VERTICAL (2:1) EXCEPT WHERE SPECIFICALLY APPROVED OTHERWISE. 7.FILLS SHALL BE COMPACTED THROUGHOUT TO A MINIMUM OF 90% RELATIVE DENSITY. AGGREGATE BASE FOR ASPHALTIC AREAS SHALL BE COMPACTED TO MINIMUM OF 95% RELATIVE DENSITY. MAXIMUM DENSITY SHALL BE DETERMINED BY UNIFORM BUILDING CODE STANDARD NO. 70-1 OR APPROVED EQUIVALENT, AND FIELD DENSITY BY UNIFORM CODE STANDARD NO. 70-2 OR APPROVED EQUIVALENT. 8.THE CONTRACTOR SHALL NOT CREATE ANY TRENCH OR EXCAVATION 5-FEET OR MORE WITHOUT THE NECESSARY PERMIT FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY. 9.ALL CUT SLOPES SHALL BE INVESTIGATED BOTH DURING AND AFTER GRADING BY THE GEOTECHNICAL ENGINEER TO DETERMINE IF ANY SLOPE STABILITY PROBLEM EXISTS. SHOULD EXCAVATION DISCLOSE ANY GEOLOGICAL HAZARDS OR POTENTIAL GEOLOGICAL HAZARDS, THE GEOTECHNICAL ENGINEER SHALL SUBMIT A RECOMMENDED TREATMENT TO THE CITY ENGINEER FOR APPROVAL. 10.THE PERMITTEE IS RESPONSIBLE FOR DUST CONTROL MEASURES. WATER ACTIVE SITES AT LEAST TWICE DAILY. 11.THE LOCATING AND PROTECTION OF ALL EXISTING UTILITIES IS THE RESPONSIBILITY OF THE PERMITTEE. 12.GRADING OPERATIONS, INCLUDING MAINTENANCE OF EQUIPMENT, WITHIN ONE-HALF (1/2) MILE OF A STRUCTURE OF HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 8:00 P.M. AND 7:00 A.M. ON WEEKDAYS, INCLUDING SATURDAY, OR ANY TIME ON SUNDAY OR A FEDERAL HOLIDAY. (CITY OF SANTA ANA MUNICIPAL CODE SECTION 18-314) 13.THE PERMITTEE SHALL GIVE REASONABLE NOTICE TO THE OWNER OF ADJOINING LANDS AND BUILDINGS PRIOR TO BEGINNING EXCAVATIONS, WHICH MAY AFFECT THE LATERAL AND SUBJACENT SUPPORT OF THE ADJOINING PROPERTY. THE NOTICE SHALL STATE THE INTENDED DEPTH OF EXCAVATION AND WHEN EXCAVATION COMMENCES. THE ADJOINING OWNER SHALL BE ALLOWED AT LEAST 30 DAYS AND REASONABLE ACCESS ON THE PERMITTED PROPERTY TO PROTECT HIS STRUCTURE, IF HE SO DESIRES, UNLESS OTHERWISE PROTECTED BY LAW. 14.ALL EXISTING DRAINAGE COURSES THROUGH THE SITE SHALL REMAIN OPEN TO HANDLE THE STORM WATER; HOWEVER, IN ANY CASE, THE PERMITTEE SHALL BE HELD LIABLE FOR ANY DAMAGE DUE TO OBSTRUCTING NATURAL DRAINAGE PATTERNS. 15.APPROVED EROSION PROTECTION DEVICES SHALL BE PROVIDED AND MAINTAINED DURING THE RAINY SEASON AND SHALL BE IN PLACE AT THE END OF EACH DAY’S WORK. PROPER EROSION CONTROL MEASURES MUST BE SHOWN ON THE PLANS. 16.CONSTRUCTION SITES SHALL BE MAINTAINED IN SUCH A CONDITION THAT AN ANTICIPATED STORM DOES NOT CARRY WASTES OR POLLUTANTS OFF THE SITES. DISCHARGES OF MATERIAL OTHER THAN STORM WATER ARE ALLOWED ONLY WHEN NECESSARY FOR PERFORMANCE AND COMPLETION OF CONSTRUCTION PRACTICES AND WHERE THEY DO NOT: CAUSE OR CONTRIBUTE TO A VIOLATION OF ANY WATER QUALITY STANDARD; CAUSE OR THREATEN TO CAUSE POLLUTION, CONTAMINATION, OR NUISANCE; OR CONTAIN A HAZARDOUS SUBSTANCE IN A QUANTITY REPORTABLE UNDER FEDERAL REGULATIONS 40 CFR 117 AND 302. POTENTIAL POLLUTANTS INCLUDE BUT ARE NOT LIMITED TO: SOLID OR LIQUID CHEMICAL SPILLS; WASTES FROM PAINTS, STAINS, SEALANTS, GLUES, LIMES, PESTICIDES, HERBICIDES, WOOD PRESERVATIVES AND SOLVENTS; ASBESTOS FIBERS, PAINT FLAKES OR STUCCO FRAGMENTS; FUELS, OILS, LUBRICANTS, AND HYDRAULIC RADIATOR OR BATTERY FLUIDS; FERTILIZERS, VEHICLES/EQUIPMENT WASH WATER AND CONCRETE WASH WATER; CONCRETE, DETERGENT OR FLOATABLE WASTES; WASTES FROM ANY ENGINE/EQUIPMENT STEAM CLEANING OR CHEMICAL DEGREASING; AND SUPERCHLORINATED POTABLE WATER LINE FLUSHINGS. DURING CONSTRUCTION, DISPOSAL OF SUCH MATERIALS SHOULD OCCUR IN A SPECIFIED AND CONTROLLED TEMPORARY AREA ON-SITE, PHYSICALLY SEPARATED FROM POTENTIAL STORM WATER RUN-OFF, WITH ULTIMATE DISPOSAL IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REQUIREMENTS. 17.DEWATERING OF CONTAMINATED GROUNDWATER, OR DISCHARGING CONTAMINATED SOILS VIA SURFACE EROSION IS PROHIBITED. DEWATERING OF NON-CONTAMINATED GROUNDWATER REQUIRES A NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT FROM THE RESPECTIVE STATE REGIONAL WATER QUALITY CONTROL BOARD. 18.ALL DIRT, SAND, MUD, OR DEBRIS DEPOSITED OR SPILLED UPON PUBLIC STREETS DURING ANY GRADING, HAULING, OR EXPORT OPERATIONS SHALL BE IMMEDIATELY CLEANED UP BY THE DEVELOPER, HIS CONTRACTOR, SUBCONTRACTORS, OR AGENTS TO THE SATISFACTION OF THE CITY ENGINEER. FAILURE TO DO SO WILL BE CAUSE FOR STOPPING ALL SUCH GRADING, HAULING, OR EXPORT WORK BY THE CITY UNTIL SUCH TIME AS THE STREETS ARE CLEANED. 19.ALL TRUCKS HAULING DIRT, SAND, OIL, OR OTHER LOOSE MATERIALS ARE TO BE COVERED OR SHOULD MAINTAIN AT LEAST TWO FEET OF FREEBOARD IN ACCORDANCE WITH THE REQUIREMENTS OF CVC SECTION 23114. 20.CONTRACTOR IS RESPONSIBLE FOR THE REPAIR OF ALL DAMAGES TO PUBLIC PROPERTIES THAT ARE CAUSED BY THE WORK ON-SITE. REPAIR MUST BE COMPLETED TO THE SATISFACTION OF THE CITY ENGINEER. 21.MINIMUM ASPHALT PAVEMENT SECTIONS SHALL BE: • 3”AC/6”AB - PARKING AISLES • 4”AC/8”AB - DRIVES [COMMERCIAL] • 4”AC/12”AB - DRIVES [INDUSTRIAL] • 3” A.C. OVER 4” A.B. - PARKING STALLS [MULTI-FAMILY] • 3” A.C. OVER 8” A.B. - DRIVE AISLES [MULTI-FAMILY] 22.EARTHWORK VOLUMES: CUT 3.73 CUBIC YARDS FILL 8.15 CUBIC YARDS NET 4.43 CUBIC YARDS 23.IF THE NET VOLUMES EXCEED 500 CUBIC YARDS, THE CONTRACTOR MUST SUBMIT A HAUL TRUCK ROUTE TO THE CITY FOR APPROVAL. HAUL ROUTE SHALL INCLUDE THE LOCATION OF BORROW AND/OR DISPERSEMENT SITE, ALL STREETS INCLUDED IN THE ROUTE, THE PROPOSED STAGING AREA AND THE MAXIMUM GROSS WEIGHT OF THE TRUCKS WHEN LOADED. 24.SUBMIT AN 8 ½” X 11” HAUL ROUTE MAP OF APPROPRIATE SCALE WHICH INDICATES THE LOCATION OF THE PROJECT SITE, SHOWING STREETS AND DIRECTION OF HAULING UP TO AND INCLUDING THE END OF THE ROUTE. 25.PURSUANT TO ASSEMBLY BILL 3019, NO EXCAVATION PERMIT IS VALID UNLESS THE CONTRACTOR CONTACTS AND OBTAINS AN INQUIRY I.D. NUMBER FROM “UNDERGROUND SERVICE ALERT” (1-800-422-4133) AT LEAST TWO WORKING DAYS PRIOR TO COMMENCING EXCAVATION. 26.SEPARATE PERMITS MUST BE OBTAINED FROM THE CITY BUILDING AND SAFETY DIVISION FOR THE CONSTRUCTION OF RETAINING WALLS, LIGHT POLES, TRASH ENCLOSURES, ON-SITE PLUMBING AND ALL BUILDING STRUCTURES. 27.ALL FONTS ON PLANS SHOULD BE A MINIMUM OF 0.1”. OWNER: NARESH ARAYA EMAIL: Nkarya@gmail.com CONTACT: 949 400 5961 OWNER INFORMATION GENERAL GRADING NOTES: C-1.0 NOTICE TO PROCEED NTP1 25. 26. LEGEND: PARCEL 1. AS SHOWN ON A MAP FILED IN BOOK 38, PAGE 25 OF PARCEL MAPS, ORANGE COUNTY, CALIFORNIA. LEGAL DESCRIPTION ENLARGED SITE CONTROL PLANC-2.1 C-5.0 EROSION CONTROL PLAN C-5.1 EROSION CONTROL DETAILS Behrooz Sarlak 4/7/2025 3 1 2 2 1 2 1 P P C L L L GR A N D A V E N U E N 0 0 ° 0 6 ' 2 0 ' ' W 66 0 . 0 1 ' (E) CC (E) AC (E) AC (E) AC (E) AC (E) PA (E) PA (E) AC (E) AC 1 2 1 2 1 2 (E) AC 10 SE-1 SE-8 SE-1 SE-8 SE-1 SE-8 4 SE-1 SE-8 TC-1 WM-9 EC-2 EC-2 WM-1 WM-3 NS-3 NS-3 NS-3 NS-3 NS-3 5 6 WM-8 EC-2 SE-7 1 CONSTRUCTION NOTES: INSTALL GRAVEL BAGS UNTIL THE COMPLETION OF THE SITE CONSTRUCTION. REFER TO DETAIL 2 ON SHEET C-5.1. SILT FENCE PER DETAIL 6 ON SHEET C-5.1. STABILIZED CONSTRUCTION ENTRANCE/EXIT PER DETAIL 4 ON SHEET C-5.1. PROPOSED AREA FOR TEMPORARY TOILETS. CONTRACTOR TO VERIFY EXACT LOCATION AND COORDINATE WITH THE CONTRACTOR PROJECT MANAGER. PROPOSED AREA FOR MATERIAL DELIVERY AND STORAGE. CONTRACTOR TO VERIFY EXACT LOCATION AND COORDINATE WITH THE CONTRACTOR PROJECT MANAGER. REFER TO DETAIL 5 ON SHEET C-5.1. CONCRETE WASTE MANAGEMENT -WM8. 2 3 4 5 6 1.LOCATION FOR ANY DESIGNATED STOCKPILES SHALL BE COORDINATED AND DETERMINED BY THE CONTRACTOR ON-SITE. CONTRACTOR SHALL APPLY ALL APPLICABLE BMP'S TO PROTECT THE STOCKPILE AS OUTLINED IN DETAIL 8 ON SHEET C-5.1. 2.CONTRACTOR SHALL FROM TIME TO TIME MONITOR THE CONSTRUCTION SITE TO CLEAN AND SWEEP MATERIALS TRACKED OFF SITE. 3.ALL BMP'S, SILT FENCES, ETC., SHALL BE MONITORED AND MAINTAINED BY THE NTP1 CONTRACTOR FOR THE ENTIRE DURATION OF THE CONTRACT. 4.CONTRACTOR SHALL NOT DISCHARGE POLLUTANTS DOWNSTREAM OF THE SETTLING BASIN/OIL SEPARATOR. THESE POLLUTANTS INCLUDE LUBRICANTS, FUELS, CHEMICALS, AND BITUMENS. CONTROL USE OF LUBRICATING OILS, HYDRAULIC FLUIDS, GREASES, AND OTHER SUCH PRODUCTS. PROMPTLY CLEAN UP AND PROPERLY DISPOSE OF MATERIALS CONTAMINATED BY SPILLAGE OR LEAKAGE OF PRODUCTS. 5.CONTRACTOR SHALL PROTECT ALL EXISTING DRAIN INLETS WITHIN A 500-FT RADIUS FROM THE CENTER OF THE SITE TO PREVENT NON-STORMWATER RUNOFF FROM ENTERING THE STORM DRAIN SYSTEM. 6.FOR EROSION CONTROL GENERAL NOTES, AND MISCELLANEOUS REQUIREMENTS, SEE SHEET C-5.1. SHEET NOTES: LEGEND: GRAVEL BAG SILT FENCE SCALE:1"=10' EROSION CONROL PLAN 0510 2000100 FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . EROSION CONTROL PLAN 7 C-5.0 Behrooz Sarlak 4/7/2025 IN CASE OF EMERGENCY, CALL: CONTRACTOR NAME ___________________________. PHONE NUMBER:_________________. A STAND-BY CREW FOR EMERGENCY WORK SHALL BE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (NOVEMBER 1 TO APRIL 15). NECESSARY MATERIALS SHALL BE AVAILABLE ON-SITE AND STOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF EMERGENCY DEVICES WHEN RAIN IS IMMINENT. EROSION CONTROL DEVICES SHOWN ON THIS PLAN MAY BE REMOVED WHEN APPROVED BY THE BUILDING OFFICIAL IF THE GRADING OPERATION HAS PROGRESSED TO THE POINT WHERE THEY ARE NO LONGER REQUIRED. GRADED AREAS ADJACENT TO FILL SLOPES LOCATED AT THE SITE PERIMETER MUST DRAIN AWAY FROM THE TOP OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY. ALL LOOSE SOILS AND DEBRIS THAT MAY CREATE A POTENTIAL HAZARD TO OFF-SITE PROPERTY SHALL BE STABILIZED OR REMOVED FROM THE SITE ON A DAILY BASIS. ALL SILT AND DEBRIS SHALL BE REMOVED FROM ALL DEVICES WITHIN 24 HOURS AFTER EACH RAINSTORM AND BE DISPOSED OF PROPERLY. A GUARD SHALL BE POSTED ON SITE WHEREVER THE DEPTH OF WATER IN ANY DEVICE EXCEEDS TWO FEET. THE DEVICE SHALL BE DRAINED OR PUMPED DRY WITHIN 24 HOURS AFTER EACH RAINSTORM. PUMPING AND DRAINING OF ALL BASINS AND DRAINAGE DEVICES MUST COMPLY WITH THE APPROPRIATE BMP FOR DEWATERING OPERATIONS. THE PLACEMENT OF ADDITIONAL DEVICES TO REDUCE EROSION DAMAGE AND CONTAIN POLLUTANTS WITHIN THE SITE IS LEFT TO THE DISCRETION OF THE QSP. ADDITIONAL DEVICES AS NEEDED SHALL BE INSTALLED TO RETAIN SEDIMENTS AND OTHER POLLUTANTS ON SITE. STORM WATER POLLUTION AND EROSION CONTROL DEVICES ARE TO BE MODIFIED, AS NEEDED, AS THE PROJECT PROGRESSES, THE DESIGN AND PLACEMENT OF THESE DEVICES IS THE RESPONSIBILITY OF THE FIELD ENGINEER. PLANS REPRESENTING CHANGES MUST BE SUBMITTED FOR APPROVAL IF REQUESTED BY THE BUILDING OFFICIAL. EVERY EFFORT MUST BE MADE TO ELIMINATE THE DISCHARGE OF NONSTORM WATER FROM THE PROJECT SITE AT ALL TIMES. ERODED SEDIMENTS AND OTHER POLLUTANTS MUST BE RETAINED ON-SITE AND MAY NOT BE TRANSPORTED FROM THE SITE VIA SHEET FLOW, SWALES, AREA DRAINS, NATURAL DRAINAGE COURSES, OR WIND. STOCKPILES OF EARTH AND OTHER CONSTRUCTION-RELATED MATERIALS MUST BE PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND OR WATER. FUELS, OILS, SOLVENTS, AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTINGS AND ARE NOT TO CONTAMINATE THE SOILS AND SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE SYSTEM. EXCESS OR WASTE CONCRETE MAY NOT BE WASTED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES ON-SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE. TRASH AND CONSTRUCTION-RELATED SOLID WASTES MUST BE DEPOSITED INTO A COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY. ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS. ANY SLOPES WITH DISTURBED SOILS OR DENUDED OF VEGETATION MUST BE STABILIZED SO AS TO INHIBIT EROSION BY WIND AND WATER. ALL WORK SHALL BE IN ACCORDANCE WITH THE EROSION CONTROL PLANS. EROSION CONTROL MEASURES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHENEVER THE DAILY RAINFALL PROBABILITY EXCEEDS 40%. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. NECESSARY MATERIALS SHALL BE AVAILABLE ON SITE AND STOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL DEVICES AT ALL TIME. CONTROLS SHALL BE SET UP AND MAINTAINED AS CONSTRUCTION PROCEEDS. ADJUSTMENTS TO THE EROSION CONTROL PLANS ARE ALLOWABLE AS REQUIRED AND APPROVED BY CITY. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL IMPLEMENT STRUCTURAL AND NONSTRUCTURAL BEST MANAGEMENT PRACTICES (BMPS) IN CONFORMANCE WITH THE GUIDELINES OF THE CALIFORNIA STORM WATER BMP HANDBOOKS. AFTER A RAINSTORM, ALL SEDIMENT AND DEBRIS SHALL BE REMOVED FROM STREETS, BERMS AND DESILTING BASINS. ANY GRADED SLOPE SURFACE PROTECTION MEASURES DAMAGED DURING A RAINSTORM SHALL BE IMMEDIATELY REPAIRED. THE PERMITTEE AND CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT TRESPASS ONTO AREAS WHERE IMPOUNDED WATER CREATED A HAZARDOUS CONDITION. EROSION AND SEDIMENT GENERAL NOTES: 12. 13. 10. 11. 7. 8. 9. 5. 6. 3. 4. 1. 2. EROSION CONTROL EC1 - SCHEDULING EC2 - PRESERVATION OF EXISTING VEGETATION EQUIPMENT TRACKING CONTROL TC1 - STABILIZED CONSTRUCTION ENTRANCE EXIT NON-STORMWATER MANAGEMENT NS2 - DEWATERING OPERATIONS NS3 - PAVING AND GRINDING OPERATIONS NS12 - CONCRETE CURING NS13 - CONCRETE FINISHING NS14 - MATERIAL AND EQUIPMENT USE TEMPORARY SEDIMENT CONTROL SE1 - SILT FENCE SE7 - STREET SWEEPING AND VACUUMING SE8 - GRAVEL BAG BARRIER WIND EROSION CONTROL WE1 - WIND EROSION CONTROL WASTE MANAGEMENT & MATERIAL POLLUTION CONTROL WM1 - MATERIAL DELIVERY AND STORAGE WM2 - MATERIAL USE WM3 - STOCKPILE MANAGEMENT WM5 - SOLID WASTE MANAGEMENT WM6 - HAZARDOUS WASTE MANAGEMENT WM8 - CONCRETE WASTE MANAGEMENT WM9 - SANITARY/SEPTIC WASTE MANAGEMENT WM10 - LIQUID WASTE MANAGEMENT 1.SOIL/SLOPE STABILIZATION PRACTICES SHALL BE DESIGNED TO PRESERVE EXISTING VEGETATION WHERE FEASIBLE AND TO REVEGETATE OPEN AREAS AS SOON AS FEASIBLE AFTER GRADING. THESE CONTROL PRACTICES SHALL INCLUDE TEMPORARY SEEDING, PERMANENT SEEDING, MULCHING, SOD STABILIZATION, VEGETATIVE BUFFER STRIPS, PROTECTION OF TREES, OR OTHER SOIL STABILIZATION PRACTICES. 2.SOIL STABILIZATION SHALL BE IMPLEMENTED ON ALL INACTIVE DISTURBED AREAS FROM NOVEMBER 1 THRU APRIL 15 AND ON ALL DISTURBED AREAS DURING A RAIN EVENT OR POTENTIAL RAIN. 3.STABILIZATION PRACTICES SHALL CONTROL/PREVENT EROSION FROM THE FORCES OF WIND AND WATER. 4.STABILIZATION PRACTICES SHALL BE IMPLEMENTED IN CONJUNCTION WITH SEDIMENT TRAPPING/FILTERING PRACTICES AND PRACTICES TO REDUCE THE TRACKING OF SEDIMENT ONTO PAVED ROADS. 5.WHEN USING STRAW MULCHING, THE MINIMUM APPLICATION SHALL BE 2 TONS/ACRE. MULCH MUST BE ANCHORED IMMEDIATELY TO MINIMIZE LOSS BY WIND OR WATER. 6.WHEN USING HYDROSEEDING/MULCHING, THE MINIMUM APPLICATION OF WOOD FIBER SHALL BE 1,500 LBS/ACRE,THAT DOES NOT CONTAIN MORE THAN 50 PERCENT NEWSPRINT. 7.FOR SEEDING RECOMMENDATIONS, USDA, NATURAL RESOURCES CONSERVATION SERVICE. NOTES: SEDIMENTS AND OTHER MATERIALS SHALL NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS SHALL BE STABILIZED SO AS TO PREVENT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC ROADS. DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS INTO THE STORM DRAIN SYSTEM. STABILIZED CONSTRUCTION ENTRANCE SHALL BE: A. LOCATED AT ANY POINT WHERE TRAFFIC WILL BE ENTERING OR LEAVING A CONSTRUCTION SITE RD OR FROM A PUBLIC RIGHT OF WAY, STREET, ALLEY, AND SIDEWALK OR PARKING AREA. B. A SERIES OF STEEL PLATES WITH "RUMBLE STRIPS", AND/OR MIN 4" COARSE AGGREGATE WITH LENGTH, WIDTH & THICKNESS AS NEEDED TO ADEQUATELY PREVENT ANY TRACKING ONTO PAVED SURFACES. ADDING A WASH RACK WITH A SEDIMENT TRAP LARGE ENOUGH TO COLLECT ALL WASH WATER CAN GREATLY IMPROVE EFFICIENCY. ALL VEHICLES ACCESSING THE CONSTRUCTION SITE SHALL UTILIZE THE STABILIZED CONSTRUCTION ENTRANCE SITES. REMOVE ALL SEDIMENT DEPOSITED ON PAVED ROADWAYS IMMEDIATELY. SWEEP PAVED AREAS THAT RECEIVE CONSTRUCTION TRAFFIC WHENEVER SEDIMENT BECOMES VISIBLE. PAVEMENT WASHING WITH WATER IS PROHIBITED IF IT RESULTS IN A DISCHARGE TO THE STORM DRAIN SYSTEM. REGULAR SWEEPING SCHEDULES SHALL BE SET UP, PARTICULARLY AFTER HEAVY RAINFALL OR CONSTRUCTION ACTIVITIES, TO ADDRESS VISIBLE DEBRIS AND ENSURE THE ROADWAYS REMAIN CLEAR OF CONTAMINANTS. VACUUM SWEEPERS, IN PARTICULAR, ARE HIGHLY EFFECTIVE AT COLLECTING FINE DUST AND PARTICLES THAT ARE HARDER TO CAPTURE WITH TRADITIONAL MECHANICAL SWEEPERS. STREET MAINTENANCE CONSTRUCT THE SILT FENCE ALONG A LEVEL CONTOUR. SILT FENCES SHALL REMAIN IN PLACE UNTIL THE DISTURBED AREA IS PERMANENTLY STABILIZED. PROVIDE SUFFICIENT ROOM FOR RUNOFF TO POND BEHIND THE FENCE AND ALLOW SEDIMENT REMOVAL EQUIPMENT TO PASS BETWEEN THE SILT FENCE AND TOE OF SLOPE OR OTHER OBSTRUCTIONS. ABOUT 1200 SQ. FT. OF PONDING AREA SHALL BE PROVIDED FOR EVERY ACRE DRAINING TO THE FENCE. TURN THE ENDS OF THE FILTER FENCE UPHILL TO PREVENT STORMWATER FROM FLOWING AROUND THE FENCE. LEAVE AN UNDISTURBED OR STABILIZED AREA IMMEDIATELY DOWNSLOPE FROM THE FENCE. DO NOT PLACE IN LIVE STREAM OR INTERMITTENTLY FLOWING CHANNELS. WHEN STANDARD FILTER FABRIC IS USED, A WIRE MESH SUPPORT FENCE SHALL BE FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS USING HEAVY-DUTY WIRE STAPLES AT LEAST 1 INCH LONG. TIE WIRES OR HOG RINGS. NOTES: SILT FENCE MAXIMUM SLOPE LENGTH COMPACTED BACKFILL TURN LOST 6' OF FENCE UP-SLOPE MAXIM U M WIDTH = 5 0 0 ' 6" 6" 18 " MAXIMUM TRIBUTARY AREA .25 ACRE/100FT OF FENCE SILT FENCE CONSTRUCTED ALONG LEVEL CONTOUR POST O 10" OC (MAX) 1. FLOW FILTER FABRIC 1. 2. 3. 4. 3 EROSION CONTROL 4 STABILIZED CONSTRUCTION ENTRANCE / EXIT PER TC-1 14. 15. 16. 17. 18. 19. 30 1. 2. 3. DIRT AND OTHER CONSTRUCTION RELATED MATERIALS PLACED IN THE STREET OR ON OTHER IMPERVIOUS SURFACES MUST BE CONTAINED WITH SANDBAGS OR OTHER MEASURES TO PREVENT TRANSPORT TO THE STORMDRAIN SYSTEM. ANY CONSTRUCTION MATERIAL STORED OR STOCKPILED ON-SITE SHALL BE PROTECTED FROM BEING TRANSPORTED BY THE FORCE OF WIND OR WATER. GRAVEL BAGS PLACE TIGHTLY TOGETHER ALL AROUND MATERIAL 1. 2. NOTES: STOCKPILED MATERIAL AS THE PROJECT OWNER OR AUTHORIZED AGENT OF THE OWNER, I HAVE READ AND UNDERSTAND THE REQUIREMENTS TO CONTROL STORM WATER POLLUTION FROM SEDIMENTS, EROSION, AND CONSTRUCTION MATERIALS, AND I CERTIFY THAT I WILL COMPLY WITH THESE REQUIREMENTS. I, OR MY REPRESENTATIVE, CONTRACTOR, DEVELOPER, OR ENGINEER, WILL MAKE CERTAIN THAT ALL BMP'S SHOWN ON THIS PLAN WILL BE FULLY IMPLEMENTED, AND ALL EROSION CONTROL DEVICES WILL BE KEPT CLEAN AND FUNCTIONING. PERIODIC INSPECTIONS OF THE BMPs WILL BE CONDUCTED AND A CURRENT LOG, SPECIFYING THE EXACT NATURE OF THE INSPECTION AND ANY REMEDIAL MEASURES, WILL BE KEPT AT THE CONSTRUCTION SITE AT ALL TIMES AND WILL BE AVAILABLE FOR THE REVIEW BY THE BUILDING OFFICIAL. AS THE PROJECT OWNER OR AUTHORIZED AGENT OF THE OWNER, "I CERTIFY THAT THIS DOCUMENT AND ALL ATTACHMENTS WERE PREPARED UNDER MY DIRECTION OR SUPERVISION IN ACCORDANCE WITH A SYSTEM DESIGNED TO ASSURE THAT QUALIFIED PERSONNEL PROPERLY GATHER AND EVALUATE THE INFORMATION SUBMITTED. BASED ON MY INQUIRY OF THE PERSON OR PERSONS WHO MANAGE THE SYSTEM OR THOSE PERSONS DIRECTLY RESPONSIBLE FOR GATHERING THE INFORMATION, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE INFORMATION SUBMITTED IS TRUE, ACCURATE, AND COMPLETE. I AM AWARE THAT SUBMITTING FALSE AND/OR INACCURATE INFORMATION, FAILING TO UPDATE THE LOCAL SWPPP TO REFLECT CURRENT CONDITIONS, OR FAILING TO PROPERLY AND/OR ADEQUATELY IMPLEMENT THE LOCAL SWPPP MAY RESULT IN REVOCATION OF GRADING AND/OR OTHER PERMITS OR OTHER SANCTIONS PROVIDED BY THE LAW." OWNER OR AUTHORIZED REPRESENTATIVE (PERMITEE) DATE OWNER STATEMENT OF UNDERSTANDING: STATEMENT OF UNDERSTANDING NOTES: 2. 3. 4. 5. 6. 7. 7 COMPACTED BACKFILL NOT TO SCALE NOT TO SCALE MATERIAL STORAGE PER WM-3 NOT TO SCALE5 6 SILT FENCE PER SE-1 NOT TO SCALE 2 GRAVEL BAG DETAIL NOT TO SCALE A SECTION A-A A 3" MIN OPENING BETWEEN TOP ROW BAGS 20. 21. 22. 4. FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . EROSION CONTROL PLAN 8 NARESH ARAYA 11/26/2024 C-5.1 HANK (ALL STAR PAVING CO.) (714) 835-9177 Behrooz Sarlak 4/7/2025 1.FOR GENERAL NOTES, LEGEND AND ABBREVIATIONS, SEE SHEET C-1.0. 2.SEE ARCHITECTURAL DRAWINGS FOR OTHER SITE RELATED DIMENSIONS NOT SHOWN ON THIS DRAWING. 3.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY SURFACE AND/ OR UNDERGROUND UTILITIES IN CONFLICT WITH THE PROPOSED DEMOLITION AND DESIGN ITEMS. CONTRACTOR SHALL REPORT ANY DISCREPANCIES AND/OR CONSTRUCTION RELATED ISSUES TO THE OWNER OR DESIGN TEAM PRIOR TO THE COMMENCEMENT OF WORK. 4.THE CONTRACTOR IS TO PROTECT THE EXISTING FOUNDATION DURING THE CONSTRUCTION OF THE SIDEWALK. SHEET NOTES: CONSTRUCTION LEGEND: CONSTRUCT NEW 4" THICK CONCRETE PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE PER DETAIL 1 ON SHEET C-4.0. OVERLAY WITH NEW LAYERS OF AC PAVEMENT A MINIMUM OF 1.5" PER DETAIL 3 ON SHEET C-4.0. INSTALL NEW CAST IN PLACE TRUNCATED DOMES PER DETAIL 7 ON SHEET C-4.0. NEW STRIPING PER ARCHITECHTURAL DRAWINGS. LIMIT OF WORK CONSTRUCT NEW 4" THICK AC PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE PER DETAIL 2 ON SHEET C-4.0. (E) BUILDING FF = 108.90 (E) BUILDING FF = 108.90' (E) BUILDING FF = 108.90' (E) AC (E) AC (E) AC (E) PA (E) PA (E) AC (E) PA (E) PA LP LC GR A N D A V E N U E N 0 0 ° 0 6 ' 2 0 ' ' W 6 6 0 . 0 1 ' (E ) CO N C R E T E S I D E W A L K (E) AC (E) AC SCALE:1"=20' OVERALL SITE CONTROL PLAN 0510 2000100 FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . OVERALL SITE CONTROL PLAN 4 C-2.0 SEE ENLARGED PLAN ON SHEET C-2.1 Behrooz Sarlak 4/7/2025 TYP TYP TYP 27 26 26 28 25 21 22 22 22 4 1 33 2 6 5 5 5 P P C L L L GR A N D A V E N U E N 0 0 ° 0 6 ' 2 0 ' ' W 66 0 . 0 1 ' (E) CC (E) AC (E) AC (E) AC (E) AC (E) PA (E) PA (E) PA (E) AC (E) AC(E) AC (E) BUILDING FF = 108.90' 29 29 29 29 30 31 31 24 31 32 32 53.04' 69.11' 9. 0 0 ' 33.81' 5 17.49' 30 . 8 7 ' 8. 6 7 ' LIMIT OF REMOVAL LIMIT OF REMOVAL LIMIT OF REMOVAL 33 23 5 5 34 9. 0 0 ' 20 . 9 1 ' 22 22 22 TYP TYP TYP 17.03' 4.79' (E ) C O N C R E T E S I D E W A L K 1 REMOVAL NOTES: 2 3 4 5 6 REMOVE EXISTING 4" AC PAVEMENT AND 4" BASE MATERIAL, FULL DEPTH. REMOVE EXISTING 4" CONCRETE PAVEMENT AND BASE MATERIAL, FULL DEPTH. GRIND 1.5" OF EXISTING AC PAVEMENT IN PREPARATION OF AC OVERLAY PER DETAIL 3 ON SHEET C-4.0. CLEAR, GRUB AND REMOVE EXISTING TURF/PLANTER/BUSH/GRAVEL EXPOSED SUBGRADE AREA. REMOVE EXISTING SHRUBS AND ROOTS IN ITS ENTIRETY. REMOVE EXISTING CONCRETE WHEELSTOP IN ITS ENTIRETY. REMOVE EXISTING TRUNCATED DOMES IN ITS ENTIRETY. PROTECT IN PLACE EXISTING TREE IN ITS ENTIRETY. PROTECT IN PLACE EXISTING CONCRETE WHEELSTOP IN ITS ENTIRETY. PROTECT IN PLACE EXISTING METAL COVER IN ITS ENTIRETY. PROTECT IN PLACE EXISTING POST INDICATOR VALVE IN ITS ENTIRETY PROTECT IN PLACE EXISTING DRAIN INLET IN ITS ENTIRETY. PROTECT IN PLACE EXISTING UTILITY VAULT IN ITS ENTIRETY. PROTECT IN PLACE EXISTING FIRE DEPARTMENT CONNECTION IN ITS ENTIRETY. PROTECT IN PLACE EXISTING FIRE HYDRANT IN ITS ENTIRETY. PROTECT IN PLACE EXISTING ASPHALT CONCRETE. PROTECT IN PLACE EXISTING BUILDING, FOUNDATION AND ALL APPURTENANCES IN ITS ENTIRETY PROTECT IN PLACE EXISTING PLANTER AREA. PROTECT IN PLACE EXISTING CONCRETE WALK. PROTECT IN PLACE EXISTING PIPE. PROTECT IN PLACE EXISTING UTILITY PULLBOX IN ITS ENTIRETY. PROTECT IN PLACE EXISTING BOLLARDS IN ITS ENTIRETY. PROTECT-IN-PLACE NOTES: 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 REMOVAL LEGEND: REMOVE EXISTING 4" AC PAVEMENT AND 4" BASE MATERIAL, FULL DEPTH. CLEAR, GRUB AND REMOVE EXISTING GRASS/PLANTER/BUSH/GRAVEL EXPOSED SUBGRADE AREA. REMOVE EXISTING SHRUBS AND ROOTS IN ITS ENTIRETY. GRIND 1.5" OF EXISTING AC PAVEMENT IN PREPARATION OF AC OVERLAY PER DETAIL 3 ON SHEET C-4.0. REMOVE EXISTING 4" CONCRETE PAVEMENT AND BASE MATERIAL, FULL DEPTH. LIMIT OF REMOVAL REMOVE EXISTING TRUNCATED DOMES IN ITS ENTIRETY. SCALE:1"=10' SITE DEMOLITION PLAN 0510 2000100 FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . SITE DEMOLITION PLAN 3 CD-1.0 Behrooz Sarlak 4/7/2025 P P C GR A N D A V E N U E N 0 0 ° 0 6 ' 2 0 ' ' W 66 0 . 0 1 ' L L (E) CC (E) AC (E) AC (E) AC (E) AC (E) PA (E) PA (E) PA (E) AC L (E) AC(E) AC (E) CC (E) BUILDING FF = 108.90' GB GB GB 108.45 FS (108.68 FS) (108.55 FS) (108.53 FS) (108.00 FS) 108.79 FS 108.88 FS 108.88 FS 107.38 FS 108.44 FS (107.85 FS)(108.14 FS) (106.59 FS=TC) (106.63 FS=TC) 108.65 FS 108.61 FS 108.67 FS 108.56 FS 108.75 FS 108.75 FS (108.64 FS)1. 0 1 % 1. 5 1 % 1. 8 0 % 1. 8 0 % 0.74% 1.00% 1. 8 2 % 1.93% 0. 4 9 % 1.98 %2.75 % 3.7 7 % 1.94% 1. 2 1 % 4.43% 1. 8 0 % 0.08% 1. 8 6 % 108.35 FS 1. 8 0 % 106.64 FS 107.18 TC 107.14 TC 106.68 FS 0.17%0.47%0.04% 3.3 0 % 1.47 % 1.17 % 108.90 FF 108.88 TH (107.69 FS=FG) 1. 2 8 % GB3. 0 1 % GB GB 107.48 FS 108.47 FS 108.88 FS 0.92% 108.97 TC 109.15 TC 109.25 TC 109.25 TC 108.75 FS 107.98 TC 107.88 TC 108.85 TC 108.47 FS 108.95 TC 109.11 TC 109.03 TC 109.08 TC109.14 TC (108.58 FS)109.25 TC 0.53% 1. 8 0 % 108.66 FS 109.17 TC 1. 8 4 % (107.45 FG) (107.54 FG) (108.65 FS) (108.19 FS) (108.67 FS) (108.02 FG) (108.51 FG) (108.23 FG) ENTRANCE DOOR (108.53 FS) EXISTING GRADEFINISHED SURFACE 6' CONCRETE CURB PER DETAIL 4/C-4.0 4" THICK CONCRETE PAVEMENT 4" THICK CRUSHED AGGREGATE 12" COMPACTED SUBGRADE 90% RELATIVE COMPACTION AC OVERLAY PER DETAIL 3/C-4.0 (E) CRUSHED AGGREGATE GB GB GB GBPL (E) BUILDING 4" THICK CONCRETE PAVEMENT 4" THICK CRUSHED AGGREGATE 12" COMPACTED SUBGRADE 90% RELATIVE COMPACTION 0" CONCRETE CURB GB GB (FF = 108.90)FINISHED SURFACE EXISTING GRADE AC OVERLAY PER DETAIL 3/C-4.0 TRUNCATED DOME PER DETAIL 7/C-4.0 NEW 6" CONCRETE CURB PER DETAIL 4 ON SHEET C-4.0 4" THICK CONCRETE PAVEMENT 4" THICK CONCRETE PAVEMENT 12" COMPACTED SUBGRADE 90% RELATIVE COMPACTION EXISTING PLANTER AREA EXISTING PLANTER AREA ESTIMATED EARTHWORK QUANTITY NOTES: ESTIMATED CUT = 3.73 CU YD ESTIMATED FILL = 8.15 CU YD ESTIMATED NET = 4.43 CU YD (FILL) SCALE:1"=10' 0510 2000100 SURVEYOR DATE: JULY 15, 2024 FLORENTINO FERRER FERRER & ASSOCIATES LAND SURVEYORS & ENGINEERS 16388 COLIMA ROAD, UNIT 206-L HACIENDA HEIGHTS, CA 91745 SURVEYOR'S NOTES 1.THIS MAP REPRESENTS A TOPOGRAPHIC SURVEY OF VISIBLE FIELD CONDITIONS AT THE TIME OF THIS SURVEY. NO EASEMENTS, COVENANTS, CONDITIONS, OR RESTRICTIONS HAVE BEEN DETERMINED EXCEPT THOSE SHOWN. 2.THE HORIZONTAL BASIS FOR THIS SURVEY IS N 00°06'20" W GRAND AVENUE PER TRACT NO. 3841 SHEET 2 OF 2 IN THE CITY OF SANTA ANA, COUNTY OF ORANGE, STATE OF CALIFORNIA. 3.THE VERTICAL BASIS FOR THIS SURVEY IS DESCRIBED BY OCS 2001 - DISTURBED - FD 3 3 4" OCS ALUMINUM BM DISK STAMPED "3B-73-68", SET IN THE TOP OF THE N END OF A CONCRETE HEAD WALL. MONUMENT IS LOCATED IN THE NE CORNER OF THE INTERSECTION OF GRAND AVE AND THE SANTA FE/TOPEKA RAILWAY, 42.8' E'LY OF THE CENTERLINE OF GRAND AVE AND 51' N'LY OF THE MOST N'LY RAIL ALONG THE RAILWAY. MONUMENT IS SET LEVEL WITH THE SIDEWALK. ELEVATION = 116.36' 4.REFER TO AUTOCAD DWG FILE FOR ADDITIONAL SURVEY POINTS AND DATA FEATURES NOT SHOWN HERE. SURVEY INFORMATION: FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . SITE GRADING PLAN AND SECTIONS 5 C-3.0 2 C-3.0 C-3.0 1 GRADING SECTION SCALE:H 1:20 V 1:5 1 GRADING SECTION SCALE:H 1:20 V 1:5 2 3.0C-3.0 SITE GRADING PLAN AND SECTIONS 1.THE ESTIMATED QUANTITIES PROVIDED ABOVE ARE FOR REFERENCE ONLY TO BE USED FOR JURISDICTIONAL PLAN CHECKING AND PERMITTING PURPOSES ONLY. 2.ESTIMATED EARTHWORK ABOVE IS BASED ON DESIGN FINISH GRADES TO EXISTING GRADES IN SURVEY. THE ESTIMATED EARTHWORK DOES NOT CONSIDER THE THICKNESS OF EACH PAVEMENT MATERIAL, FOUNDATION AND SLAB ON GRADE VOLUMES, THE REMOVAL OF ANY UNSUITABLE MATERIAL, AND THE REMOVAL OF EXISTING BASEMENTS, PITS, VAULTS, TOP SOIL OR VEGETATION. 3.THE ESTIMATED EARTHWORK QUANTITIES DO NOT INCLUDE SHRINKAGE FACTORS DUE TO COMPACTION OR ANY OVER EXCAVATION QUANTITIES. 4.ESTIMATED EARTHWORK QUANTITIES ABOVE ASSUME THAT ALL ON-SITE MATERIALS ARE SUITABLE FOR BACKFILLING. HOWEVER, ACTUAL EXISTING ON-SITE MATERIALS AND IMPORTED MATERIALS MUST FIRST BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO INSTALLATION, REMOVAL, OR REPLACEMENT. 5.INFORMATION SHOWN WITHIN THE CONSTRUCTION DOCUMENTS WAS DERIVED FROM AS-BUILT PLANS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THE CONSTRUCTION DOCUMENTS. IF ANY DISCREPANCIES ARISE, CONTRACTOR SHALL INFORM OWNER AND DESIGN TEAM. 3 C-3.0 GRADING SECTION SCALE:H 1:20 V 1:5 3 3.0 Behrooz Sarlak 4/7/2025 NOTES: A+ B M I N . 8" 1 1 1 1 A+ B M I N . 8" FACE OF WALL/ BLDG. 1/2" EXPANSION JOINT # 4 @ 12" O.C. # 4 @ 12" O.C. FLUSH WHEN ADJACENT TO HARDSCAPE. PROVIDE 1-1/2" DEPRESSION FOR LANDSCAPE AREA. EDGE CONDITION AT HARDSCAPE OR LANDSCAPE WHERE OCCURS PER PLAN A" B" EQ . EQ . FINISH SURFACE PER GRADING CONCRETE PAVEMENT #4 @ 12" O.C. CRUSHED AGGREGATE BASE @ 95% RELATIVE COMPACTION SCARIFY AND RECOMPACT TOP 12" OF SUBGRADE TO 90% RELATIVE COMPACTION EDGE CONDITION AT HARDSCAPE / LANDSCAPE EDGE CONDITION AT BLDG. FACE NOTES: 1/8" DE P T H = 1/ 4 S L A B TH I C K N E S S 12" MAX 1/8" DE P T H = 1/ 4 S L A B TH I C K N E S S LEGENDS: 1 2 1 3 1 7 3 5 1 7 6 4 3 0. 9 6 7 " 0. 7 2 2 " 0. 2 5 " NOTES: 0.90" AT BASE 0.45" AT TOP PLAN LOCATION THICKNESS THICKNESS NON-TRAFFIC 4" "A" 4" "B" PAVEMENT CONCRETE AGGREGATE BASE CRUSHED 1.CONCRETE, F'C = 2,500 PSI @ 28 DAYS. 2.REBARS, FY=60,000 PSI ASTM A615. 3.FOR WPJ CONSTRUCTION JOINTS AND PATTERN, REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS. 4.CRACK CONTROL JOINTS SHALL BE SPACED @ INTERVALS NOT GREATER THAN 10' USING SAWCUTS AND EXTEND MINIMUM OF 1/4 THE SLAB THICKNESS. 5.FOR FINISH SURFACES, COLOR INTEGRATION, EXPANSION JOINTS AND OTHER PAVEMENT SURFACE FEATURES, SEE ARCHITECTURAL & DRAWINGS. 6.FOR PAVEMENT TRANSITIONAL AND JOINT DETAILS REFER TO DETAIL 5 AND 6 ON THIS SHEET. 7.LANDSCAPE, TURF AND PLANTING AREA TO BE 1-1/2" BELOW ADJACENT CONCRETE PAVEMENT. 8.PROVIDE THICKENED EDGE FOR ALL EDGE CONDITIONS. SCARIFY AND RECOMPACT TOP 12" OF SUBGRADE TO 90% RELATIVE COMPACTION SCARIFY AND RECOMPACT TOP 12" OF SUBGRADE TO 90% RELATIVE COMPACTION 1.PROVIDE 1/4" EXPANSION JOINT WITH SELF-SEALING PREFORMED JOINT FILLER AT ALL ANGLE POINTS AND THE BEGINNING AND END OF ALL CURVES. 2.PROVIDE CONTRACTION JOINTS CONSISTING OF ONE INCH DEEP CUT SCORES AT 20' O.C. MAX. 3.WHERE A WALK IS ADJACENT TO THE CURB, THE JOINTS SHALL LINE WITH JOINTS IN THE WALK. 4.CONCRETE, F'C=3,000 PSI @ 28 DAYS. 5.REBARS, FY=60,000 PSI ASTM A615. 6.CONCRETE GUTTER IS A MODIFIED DETAIL OF CITY OF SANTA ANA STD. PLAN NO. 1101 DETAIL B-1 OR B-3. 1.PAVING FINISH SURFACE. 2.SAWCUT. 3.1/8" R. @ EDGES. TYP. 4.PREMOLDED E.J. FILLER. 5.JOINT SEALANT. COLOR TO BE SELECTED BY ARCHITECT. SUBMIT COLOR SAMPLES PRIOR TO INSTALLATION. 6.BACKER ROD. 7.18" #4 REBAR W/ 'SPEED DOWEL' @ 36" O.C., CENTER IN CONC. AT COLD JOINTS & E.J.'S. 8.EXPANSION JOINTS 20 O.C. MAX. COORDINATE WITH LANDSCAPE DRAWING FOR JOINT LOCATIONS. 9.CONTRACTOR TO SUBMIT SHOP DRAWINGS OF CONTROL JOINT AND EXPANSION JOINT LAYOUT. A: SAWCUT JOINT D: EXPANSION JOINTB: TOOLED JOINT C: COLD JOINT SURROUNDING PEDESTRIAN SURFACE DOME TILE TRUNCATED DOMES SHALL BE CAST IN PLACE REPLACEABLE TACTILE AND 33538 YELLOW 0.883" 1. ONLY APPROVED DSA-AC DETECTABLE WARNING PRODUCTS (TRUNCATED DOMES) AND DIRECTIONAL SURFACES SHALL BE INSTALLED AS PROVIDED IN THE CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 1, ARTICLES 2, 3 AND 4. REFER TO CCR TITLE 24, PART 12, CHAPTERS 12-11A AND B-102, FOR BUILDING AND FACILITY ACCESS SPECIFICATIONS FOR PRODUCT APPROVAL FOR DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACES. [CBC 11B-247.1] 2.REFER TO CITY OF SANTA ANA STANDARD PLAN NO. 1122 FOR ALL ADDITIONAL REQUIREMENTS AND DIMENTIONS RELATED TO TRUNCATED DOMES. 3.SEE MANUFACTURER'S (ADA SOLUTIONS, INC.) DRAWINGS AND SPECIFICATIONS FOR MORE DETAILS. 1. 7 0 " 1.70" P. O . T . TRUNCATED DOMES SHALL BE CAST IN PLACE REPLACEABLE TACTILE AND 33538 YELLOW OF SAE AMS-STD-595A. PANEL JOINT. DOME SPACING & PATTERN OF THE NEXT PANEL SHALL CONTINUE AT THE SAME SPACING TWO COATS OF SURFACE SEAL PER SPECIFICATIONS 1. 5 " ( M I N ) 1.5" MIN AC OVERLAY TO MEET NEW DESIGN GRADE PER GRADING PLANS PROVIDE TACK COAT BETWEEN (N) AND (E) AC PER APWA STANDARD SPECIFICATIONS SECTION 302-5.4 (2021 EDITION) GRIND 1.5" OF EXISTING AC PAVEMENT BEFORE OVERLAY OF NEW LAYERS NOTES: 1. FOR PAVEMENT TRANSITIONAL DETAIL REFER TO DETAIL 6 ON THIS SHEET. 2.AFTER AC OVERLAY, PAINT WITH SOLAR REFLECTIVE COATING PER ARCHITECTURAL DRAWINGS. 3. SEE SPEC 32.1236 FOR COATS OF SEAL SURFACE. 4. USE TACK COAT TYPE AR-4000 OR APPROVED EQUAL. APPLICATION RATE SHALL BE 0.05 GALLON / SQUARE YARD. SEE SECTION 302-5 OF THE STANDARD SPECIFICATIONS FOR TRACKING PROTECTION AND CLEAN-UP REQUIREMENTS. 5. CONTRACTOR SHALL EXERCISE CARE TO PREVENT THE TACK COAT FROM BEING APPLIED ON OTHER THAN THE AREA TO BE PAVED, AND SHALL BE RESPONSIBLE FOR REMOVING ANY TACK COAT FROM SURFACES NOT DESIGNATED TO BE PAVED AT NO COST TO THE OWNER. PAVEMENT TRANSITIONAL DETAIL6NOT TO SCALE CONCRETE PAVEMENT DETAIL1NOT TO SCALE ASPHALT PAVEMENT SECTION2NOT TO SCALE CAST IN PLACE TRUNCATED DOME DETAIL7NOT TO SCALE CONCRETE CURB DETAIL4NOT TO SCALE JOINT DETAIL5NOT TO SCALE NOTE: A B TABLE AC PAVEMENT SURFACING TYPE III, C3, PG-64-10 1.FOR PAVEMENT TRANSITION REFER TO DETAIL 6 ON THIS SHEET. SCARIFY AND RECOMPACT TOP 12" OF SUBGRADE TO 90% RELATIVE COMPACTION CRUSHED AGGREGATE BASE RECOMPACTED TO 95% RELATIVE COMPACTION TWO COATS OF SURFACE SEAL 3" GRADE C3 "A" BASE COURSE 6" LOCATION AC THICKNESS TYPE CAB FINE THICKNESSCLASS PARKING/LIGHT TRAFFIC "B" AC OVERLAY DETAIL3NOT TO SCALE EXIST AC PAVEMENT NEW CONSTRUCTION/ AC PAVEMENT EXIST BASENEW BASE 1'-0"REMOVE EXISTING AC AND REPLACE WITH NEW AC PAVEMENT EXISTING BASE COURSE EDGE NEATLY SAWCUTTACK COAT FULL DEPTH EXIST AC PAVEMENT NEW CC PAVEMENT EXIST BASENEW BASE EDGE NEATLY SAWCUTTACK COAT FULL DEPTH NEW BASE COURSE NEW BASE COURSE TYP. SECTION: 2-#4 CONT. BAR SCARIFY AND RECOMPACT TOP 12" OF SUBGRADE TO 90% RELATIVE COMPACTION EXIST LANDSCAPE AREA NEW CC PAVEMENT NEW BASE 1-1/2" DEPRESSION FOR LANDSCAPE AREA. TACK COAT FULL DEPTH NEW BASE COURSE FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . MISCELLANEOUS DETAIL TOP OF CURB FLOWLINE 6" 6" 12" 6"6" 12" 6" BOTTOM OF CURB TOP OF CURB CONCRETE CURB CONCRETE CURBCONCRETE CURB PAVEMENT PER SITE PLAN CURB SLOT DETAIL8NOT TO SCALE 6 C-4.0 CONCRETE PAVEMENT PER DETAIL 1 ON THIS SHEET OR LANDSCAPE WHERE OCCURS LANDSCAPE OR HARDSCAPE (SEE GRADING PLAN FOR ELEVATION) 6" M I N 8" M I N 3:12 BATTER TC ELEVATION PER GRADING PLAN ON SHEET C-3.0. FS ELEVATION PER GRADING PLAN ON SHEET C-3.0. R=1 2" TYP. 6" 2-#4 CONT. BAR SCARIFY AND RECOMPACT TOP 12" OF SUBGRADE TO 90% RELATIVE COMPACTION LANDSCAPE OR HARDSCAPE (SEE GRADING PLAN FOR ELEVATION) 3:12 BATTER TC ELEVATION PER GRADING PLAN ON SHEET C-3.0. FS ELEVATION PER GRADING PLAN ON SHEET C-3.0. R=1 2" TYP. 6" AC OVERLAY PER DETAIL 3 ON THIS SHEET CONCRETE CURB AT HARDSCAPE / LANDSCAPE CONCRETE CURB AT AC OVELAY Behrooz Sarlak 4/7/2025 (E) BUILDING FF = 108.90 8.50' 18 . 0 0 ' 9.00'8.00'9.00'8.50'8.50' 2 1 4 3 7 TYP 4 4 51.47'17.64' 8. 0 0 ' 7. 5 0 ' (E) BUILDING FF = 108.90' P P C L L L GR A N D A V E N U E N 0 0 ° 0 6 ' 2 0 ' ' W 66 0 . 0 1 ' (E) CC (E) AC (E) AC (E) AC (E) AC (E) PA (E) PA (E) PA (E) AC (E) AC(E) AC 38.60' (E) AC 5TYP5TYP5 6START 4. 0 0 ' 4 1 31 . 0 0 ' TYP 5 TYP 21 . 4 1 ' 9. 1 7 ' LIMIT OF WORK LIMIT OF WORK LIMIT OF WORK 3 TYP 10 . 0 7 ' 60.57'42.64' (E ) C O N C R E T E S I D E W A L K 70.08' 6 END 8 8 8 1 8 END6 8 8 6 69.75' 16.68' 9 9 1 CONSTRUCTION NOTES: CONSTRUCT NEW 4" THICK CONCRETE PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE PER DETAIL 1 ON SHEET C-4.0. CONSTRUCT NEW 4" THICK AC PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE (CAB) PER DETAIL 2 ON SHEET C-4.0. OVERLAY WITH NEW LAYERS OF AC PAVEMENT A MINIMUM OF 1.5" PER DETAIL 3 ON SHEET C-4.0. NEW STRIPING PER ARCHITECTURAL DRAWINGS. INSTALL NEW WHEEL STOP PER ARCHITECTURAL DRAWINGS. CONSTRUCT NEW 6" CONCRETE CURB PER DETAIL 4 ON SHEET C-4.0. INSTALL NEW CAST IN PLACE TRUNCATED DOMES PER DETAIL 7 ON SHEET C-4.0. CONSTRUCT CONCRETE CURB SLOT PER DETAIL 8 ON SHEET C-4.0. ACCESSIBLE SIGNAGE PER ARCHITECTURAL DRAWINGS. 2 3 4 5 6 7 8 9 CONSTRUCTION LEGEND: CONSTRUCT NEW 4" THICK CONCRETE PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE PER DETAIL 1 ON SHEET C-4.0. OVERLAY WITH NEW LAYERS OF AC PAVEMENT A MINIMUM OF 1.5" PER DETAIL 3 ON SHEET C-4.0. INSTALL NEW CAST IN PLACE TRUNCATED DOMES PER DETAIL 7 ON SHEET C-4.0. NEW STRIPING PER ARCHITECHTURAL DRAWINGS. LIMIT OF WORK CONSTRUCT NEW 4" THICK AC PAVEMENT OVER 4" THICK CRUSHED AGGREGATE BASE PER DETAIL 2 ON SHEET C-4.0. 1.FOR GENERAL NOTES, LEGEND AND ABBREVIATIONS, SEE SHEET C-1.0. 2.SEE ARCHITECTURAL DRAWINGS FOR OTHER SITE RELATED DIMENSIONS NOT SHOWN ON THIS DRAWING. 3.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY SURFACE AND/ OR UNDERGROUND UTILITIES IN CONFLICT WITH THE PROPOSED DEMOLITION AND DESIGN ITEMS. CONTRACTOR SHALL REPORT ANY DISCREPANCIES AND/OR CONSTRUCTION RELATED ISSUES TO THE OWNER OR DESIGN TEAM PRIOR TO THE COMMENCEMENT OF WORK. 4.THE CONTRACTOR IS TO PROTECT THE EXISTING FOUNDATION DURING THE CONSTRUCTION OF THE SIDEWALK. SHEET NOTES: SCALE:1"=10' ENLARGE SITE CONTROL PLAN 0510 2000100 SURVEYOR'S INFORMATION: SURVEYOR DATE: JULY 15, 2024 FLORENTINO FERRER FERRER & ASSOCIATES LAND SURVEYORS & ENGINEERS 16388 COLIMA ROAD, UNIT 206-L HACIENDA HEIGHTS, CA 91745 SURVEYOR'S NOTES 1.THIS MAP REPRESENTS A TOPOGRAPHIC SURVEY OF VISIBLE FIELD CONDITIONS AT THE TIME OF THIS SURVEY. NO EASEMENTS, COVENANTS, CONDITIONS, OR RESTRICTIONS HAVE BEEN DETERMINED EXCEPT THOSE SHOWN. 2.THE HORIZONTAL BASIS FOR THIS SURVEY IS N 00°06'20" W GRAND AVENUE PER TRACT NO. 3841 SHEET 2 OF 2 IN THE CITY OF SANTA ANA, COUNTY OF ORANGE, STATE OF CALIFORNIA. 3.THE VERTICAL BASIS FOR THIS SURVEY IS DESCRIBED BY OCS 2001 - DISTURBED - FD 3 3 4" OCS ALUMINUM BM DISK STAMPED "3B-73-68", SET IN THE TOP OF THE N END OF A CONCRETE HEAD WALL. MONUMENT IS LOCATED IN THE NE CORNER OF THE INTERSECTION OF GRAND AVE AND THE SANTA FE/TOPEKA RAILWAY, 42.8' E'LY OF THE CENTERLINE OF GRAND AVE AND 51' N'LY OF THE MOST N'LY RAIL ALONG THE RAILWAY. MONUMENT IS SET LEVEL WITH THE SIDEWALK. ELEVATION = 116.36' 4.REFER TO AUTOCAD DWG FILE FOR ADDITIONAL SURVEY POINTS AND DATA FEATURES NOT SHOWN HERE. FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . SITE CONTROL PLAN 4 C-2.1 Behrooz Sarlak 4/7/2025 110.00' P P C (E) AC GR A N D A V E N U E N 0 0 ° 0 6 ' 2 0 ' ' W 66 0 . 0 1 ' L L (E) CC (E) AC (E) AC (E) AC (E) CC (E) AC (E) PA (E) PA (E) PA (E) AC (E) AC L (E) AC (E) AC (E) AC(E) AC (E) CC (E) BUILDING FF = 108.90 S 0 0 ° 0 1 ' 5 8 ' ' E CL E WAKEHAM AVE CL NORMANDY PL SCALE:1"=10' EXISTING CONDITIONS 0510 2000100 ABBREVIATIONS: AC ASPHALT CONCRETE BACK OF SIDEWALKBSW BS BLUE STRIPE CONCRETEC/CONC/CC CAR STOPCRS CONCRETE SLABCS DRAIN INLETDI DOUBLE WHITE STRIPEDWS EDGE OF CONCRETEEC EDGE OF PAVEMENTEP EDGE OF GUTTEREG ELECTRIC PULL BOXEPB FLOW LINEFL FIRE DEPARTMENT CONNECTIONFDCONN GROUNDGRD FINISH FLOORFF FIRE HYDRANTFH GRADE BREAKGB METAL COVERMC PULL BOXPB POST INDICATOR VALVEPIV ROOF DRAINRD TOP CURBTC TRUNCATED DOME PADTDP THRESHOLDTHR TRAFFIC SIGNAL PULL BOXTSPB WHITE STRIPEWS PROPERTY LINEPL CENTER LINECL LEGENDS: PALM TREE PULL BOX DRAIN INLET PIPE FIRE HYDRANT ROOF DRAIN CONTOUR LINE PROPERTY LINE CENTER LINE C L PILLAR/BUILDING PL POST INDICATOR VALVE FIRE DEPARTMENT CONNECTION ## - DIA IN INCHES SURVEYOR DATE: JULY 15, 2024 FLORENTINO FERRER FERRER & ASSOCIATES LAND SURVEYORS & ENGINEERS 16388 COLIMA ROAD, UNIT 206-L HACIENDA HEIGHTS, CA 91745 SURVEYOR'S NOTES 1.THIS MAP REPRESENTS A TOPOGRAPHIC SURVEY OF VISIBLE FIELD CONDITIONS AT THE TIME OF THIS SURVEY. NO EASEMENTS, COVENANTS, CONDITIONS, OR RESTRICTIONS HAVE BEEN DETERMINED EXCEPT THOSE SHOWN. 2.THE HORIZONTAL BASIS FOR THIS SURVEY IS N 00°06'20" W GRAND AVENUE PER TRACT NO. 3841 SHEET 2 OF 2 IN THE CITY OF SANTA ANA, COUNTY OF ORANGE, STATE OF CALIFORNIA. 3.THE VERTICAL BASIS (BENCHMARK) FOR THIS SURVEY IS DESCRIBED BY OCS 2001 - DISTURBED - FD 3 3 4" OCS ALUMINUM BM DISK STAMPED "3B-73-68", SET IN THE TOP OF THE N END OF A CONCRETE HEAD WALL. MONUMENT IS LOCATED IN THE NE CORNER OF THE INTERSECTION OF GRAND AVE AND THE SANTA FE/TOPEKA RAILWAY, 42.8' E'LY OF THE CENTERLINE OF GRAND AVE AND 51' N'LY OF THE MOST N'LY RAIL ALONG THE RAILWAY. MONUMENT IS SET LEVEL WITH THE SIDEWALK. ELEVATION = 116.36' 4.REFER TO AUTOCAD DWG FILE FOR ADDITIONAL SURVEY POINTS AND DATA FEATURES NOT SHOWN HERE. SURVEY INFORMATION: FILE NO.:TENANT IMPROVEMENT PLAN PROJECT LIMITS CITY OF SANTA ANA PUBLIC WORKS AGENCY REVISIONS REFERENCES NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED CONSTRUCTION COMPLETED:SHEET _ OF 8 BENCHMARK NO.:ELEV.: DATE 08/2024DESIGNED: AL DRAWN: RF CHECKED: TD 08/2024 RECOMMENDED FOR CONSTRUCTION: REVIEWED FOR CONSTRUCTABILITY: PRINCIPAL CIVIL ENGINEER 08/2024 PRINCIPAL CIVIL ENGINEER PREPARED UNDER THE SUPERVISION OF: RCE NO.:36079 RCE NO.: SENIOR CIVIL ENGINEER PR O J E C T N O . Y Y - N N N N : 1 0 0 1 S G R A N D A V E . EXISTING CONDITIONS 2 C-1.1 EXISTING DRAINAGE PATTERN/FLOW Behrooz Sarlak 4/7/2025