HomeMy WebLinkAbout5514 W Rhonda Ave - Plan518 Lake Cleveland Street Burley,ID 83318 1-208-994-1680 1002094 08/09/2024 Structure:Single Story Residence Address: 5514 Rhonda Avenue Santa Ana, California 92703, Orange County Codes & Standards: Jurisdiction:City of Santa Ana Solar Array Components Adequate¹ Solar Array Anchorage to Roof Adequate Roof Structure Adequate Note: 1) Only includes items listed in Table 1. Respectfully, Professional Engineering Team PV Letters To whom it may concern, This structural report shall state the structural adequacy of the existing building structure to support the solar array installation proposed in Permit Drawings by Illumine-i (Project: 5514 Rhonda Avenue, Santa Ana, California 92703, dated 08/08/2024, Rev A). Based upon our analysis of the proposed installation to the existing structure, we have determined the adequacy of the following components to be as follows: This analysis will be affected if any conditions throughout the report or associated permit drawings are not also represented on-site. Contractor shall notify the engineer of record of any discrepancies and receive written approval from the engineer of record before proceeding with installation. If there are any questions or further assistance required, please call. Project Information: Structural Report for Solar Array Installation PV Letters Project #: Issued Date: Design Requirements:2022 CRC (ASCE 7-16), 2022 CBC, 2022 CEBC trevor@pvletters.com Project Name: 5514 Rhonda Avenue, Santa Ana, California 92703 5514 W Rhonda Ave11/27/2024 Project Name: 5514 Rhonda Avenue, Santa Ana, California 92703 Issued Date: 08/09/2024 Solar Array Installation Page | 2 Page #: 2 3 4 5 1) INTRODUCTION Source SEG Solar Inc. SnapNrack SnapNrack Note: 1) All components are verified to withstand design criteria either based upon referenced rating letters or by calculations provided in this report. YUKON SERIES BLACK DIAMOND HALF CELL 400- 415W Solar Panels Spec Sheet by SEG SOLAR, document ID: SEG_DS_2023-02_Rev01_EN SpeedSeal foot (Framing Mount) Roof Attachment System Report # 2019-13746.004 – SnapNrack Ultra Rail SpeedSeal Foot Pre- Production, by PZSE, Inc. - Structural Engineers, dated 3/9/2020 SnapNrack UR-40 Rail System Report # 2017-03227.11 – Engineering Certification and Span Tables for the SnapNrack Ultra Rail Solar Photovoltaic Racking System, by PZSE, Inc. - Structural Engineers, dated 2/26/2020 4) CALCULATIONS Table 1 – List of Solar Panel Array Components Component Description Rating Letter Info The solar panel array shall be installed on the existing single story residence. The structure is wood framed. The roof structure is composed of 2x4 rafters spaced at 2'-0" on center. Original building drawings are unavailable; however, site information was obtained during a site visit by Next Phase Electric. The solar panel array is composed of components shown in Table 1. 3.2) Limitations TABLE OF CONTENTS 1) INTRODUCTION Table 1 – List of Solar Panel Array Components 2) DESIGN CRITERIA 3) DISCLAIMERS 3.1) Assumptions 5514 W Rhonda Ave11/27/2024 Project Name: 5514 Rhonda Avenue, Santa Ana, California 92703 Issued Date: 08/09/2024 Solar Array Installation Page | 3 Wood Framing: 5 psf 0 psf Solar Array: 3 psf 1.0 1.0 Asphalt Shingles: 2 psf 1.0 1/2" Plywood: 1.6 psf 1.0 0 psf 20 psf 115 mph 89.1 mph II B 0.18 II 1.0 D(default) DSeismic Design Category: Seismic Importance Factor, IE: Mapped Spectral Response Acceleration Parameters:SS: 1.339, S1: 0.477 Design Spectral Response Acceleration Parameters:SDS: 1.071, SD1: 0.58 Site Class (Assumed): Risk Category: Slope Factor, Cs: Flat Roof Snow Load, pf: Live Loads Roof Live Load: Wind Loads Basic Design Wind Speed, V: Allowable Stress Design Wind Speed, Vasd: Risk Category: Exposure Category: GCpi (+/-): Seismic Loads Thermal Factor, Ct: 2) DESIGN CRITERIA Code & Standards: Dead Loads Snow Loads Ground Snow Load, pg: Snow Exposure Factor, Ce: Snow Importance Factor, Is: 2022 CRC (ASCE 7-16), 2022 CBC, 2022 CEBC 5514 W Rhonda Ave11/27/2024 Project Name: 5514 Rhonda Avenue, Santa Ana, California 92703 Issued Date: 08/09/2024 Solar Array Installation Page | 4 Wall Framing No. 2 Douglas Fir Larch 2. All solar panel array components listed in Table 1 shall be designed and installed per the manufacturer’s approved installation specifications. 3. The existing building structure was properly constructed and maintained in good condition. 3.2 LIMITATIONS 1. Waterproofing around the roof penetrations is the responsibility of others. 2. No allowance has been made in this report for any existing deficiency in design, material, construction, or lack of maintenance for the existing structure or proposed equipment. 3. Any miscellaneous items not explicitly listed in this report have not been designed or detailed by PV Letters. It is recommended that material of suitable size and strength be obtained from a reputable manufacturer for miscellaneous items. 4. The referenced permit plans are schematic representations of the installation of proposed equipment to the existing structure. The contractor shall be responsible for field verifying existing conditions, proper fit, and clearances in the field. 5. Construction documents depicting the required modifications for installation are obtainable from PV Letters, but are beyond the scope of this report. 3) DISCLAIMERS 3.1 ASSUMPTIONS 1. Wood framing meets the following specifications in accordance with the ANSI/AWC “National Design Specification” (2018 Edition). Roof Framing No. 2 Douglas Fir Larch 5514 W Rhonda Ave11/27/2024 Project Name: 5514 Rhonda Avenue, Santa Ana, California 92703 Issued Date: 08/09/2024 Solar Array Installation Calculations: Page | 1 l.Component & Cladding Wind Calculations Site Data Basic Design Wind Speed, V: 115 mph Exposure Category: B Risk Category: II Topo Factor, Kzt: 1.00 Building Data Mean Roof Height, h: 15 ft Building Type: Enclosed Roof Type: Hip Roof Slope: 18 ° Least Horizontal Building Length: 17 ft Largest Horizontal Building Length: 50 ft Estimated Building Area: 3000 ft2 Roof dimension, 'a' per ASCE7: 3 ft Wind Data Velocity Pressure Coef, Kz: 0.700 Wind Directionality Factor, Kd: 0.85 Ground Elevation Factor, Ke: 1.0 Velocity Pressure @ Height, qh: 19.9 psf Effective Wind Area, A: 20.0 ft2 Component & Cladding Wind Pressures Positive Pressure for Effective Area, A = 20 SF* Roof Zone (GCp) (GCpi, +/-) Max Positive Pressure (psf) All Zones 0.58 0.18 15.15 *Positive notation indicates wind pressure acting downwards on roof Negative Pressure for Effective Area, A = 20 SF* Roof Zone (GCp) (GCpi, +/-) Max Negative Pressure (psf) 1 -1.80 0.18 -39.49 2r -2.15 0.18 -46.38 2e & 3 -2.32 0.18 -49.90 *Negative notation indicates wind pressure acting away from roof *Wind calculations according to ASCE 7-16* 5514 W Rhonda Ave11/27/2024 Project Name: 5514 Rhonda Avenue, Santa Ana, California 92703 Issued Date: 08/09/2024 Solar Array Installation Calculations: Page | 2 ll.Wind Forces on Solar Panel System Panel Data Short Length of Panel: 45 in Long Length of Panel: 68 in Quantity of Panels: 30 *Panel Pressure Panel Location (Roof Zone) Eff. Wind Area, A (ft2) γa, Fig. 29.4-8 γE, uplift γE, others Positive Pressure (psf) Uplift Pressure (psf) Service Uplift Pressure (psf) 1 21.0 0.751 1.5 1.0 11.25 -43.93 -26.36 2r 21.0 0.751 1.5 1.0 11.25 -51.84 -31.11 2e & 3 21.0 0.751 1.5 1.0 11.25 -55.77 -33.47 *Panel pressures only calculated for roof zones where solar panels are present. Attachment Data Connection # 1:Connection # 2: Max CNX Spacing: 4.00 ft Max CNX Spacing: 4.00 ft Panel Attachments, Withdrawal CNX # Attach. Location (Roof Zone) Trib. Wind Area, A γa γE, uplift Uplift Pressure (psf) Withdrawal Force (lbs) Service Withdrawal Force (lbs) 1 2e & 3 11.3 0.8 1.5 -64.89 -733.1 -439.9 Applied Load: -439.88 lbs Allowable Load: -802.00 lbs Safe Note: *Wind calculations according to ASCE 7-16* 1) The system is safe since the allowable capacity is greater than the service withdrawal force. 2) See the rating letter info on page 2 in Table-1 for additional information on attachments capacity. Attachments are along..(x)..of panel:Short Side Attachments are along..(x)..of panel:Long Side 5514 W Rhonda Ave11/27/2024 Project Name: 5514 Rhonda Avenue, Santa Ana, California 92703 Issued Date: 08/09/2024 Solar Array Installation Calculations: Page | 3 III.Gravity Loads Roof Dead Loads Roof Dead Loads with Panels Asphalt Shingles:2 psf Solar Array 3 psf 1/2" Plywood:1.6 psf psf psf psf psf psf Total Existing Dead Load:3.6 psf Total New Dead Load:6.6 psf Roof Live Loads Roof Live Loads with Panels 16.0 psf 0 psf Snow Loads Snow Loads with Panels Ground Snow Load, pg:0 psf Thermal Factor, Ct:1.0 Snow Exposure Factor, Ce:1.0 Flat Roof Snow Load, pf:0.0 psf Snow Importance Factor, Is:1.0 Slope Factor, Cs:1.0 Thermal Factor, Ct:1.0 Sloped Roof Snow Load, ps:0.0 psf Flat Roof Snow Load, pf:0 psf Slope Factor, Cs:1.0 Sloped Roof Snow Load, ps:0 psf Gravity Load Comparison Factored Load Combinations Exist. Weight (psf) New Weight (psf) 1.4 DL:5.0 9.2 1.2 DL + 1.6 Lr:29.9 7.9 1.2 DL + 1.6 S:4.3 7.9 Maximum Factored Gravity Loads:29.9 9.2 % Increase in Factored Weight:-69.1% Roof Live Load @ Location w/ Solar Array: Per Section 503.3 of the 2022 CEBC, any existing gravity load-carrying structural element for which an alteration causes an increase in design dead, live, or snow load, including drift effects, of more than 5% shall be replaced or altered as needed to carry the gravity loads by the CBC for new structures. Since there is no increase of gravity load greater than 5%, the existing structure is adequate for the alteration. Existing Design Roof Live Load (reduced for sloped roof): 5514 W Rhonda Ave11/27/2024 Project Name: 5514 Rhonda Avenue, Santa Ana, California 92703 Issued Date: 08/09/2024 Solar Array Installation Calculations: Page | 4 IV.Seismic Loads Seismic Weight Existing Roof Dead Load:8.6 psf Roof Dead Load @ Panel Locations:11.6 psf Quantity of Pre-Existing Panels:0 % of Roof w/ Solar Panels:21.0% Equiv. Seismic Weight Increase:7.3% Per Section 503.4 of the 2022 CEBC, any existing lateral load-carrying element whose demand-capacity ratio with the alteration considered is not more than 10% greater than its demand-capacity ratio with the alteration ignored shall be permitted to remain unaltered. Since there is no increase of seismic weight greater than 10%, the existing lateral load-carrying elements are adequate for the alteration. 5514 W Rhonda Ave11/27/2024 Expedited Permit Process for PV Systems - Micro-Inverter1 Expedited Permit Process for PV Systems Micro-Inverter The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Micro-Inverter to use with the Expedited Per- mit Process. The Standard String, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 5514 W Rhonda Ave11/27/2024 Expedited Permit Process for PV Systems — Micro-Inverter 2 Expedited Permit Process for Small-Scale PV Systems Micro-Inverter The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1.Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2.Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3.Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1.Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2.Does the roof have a single roof covering?l Yes l No If No, submit completed worksheet for roof structure WKS1. 3.Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1.Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2.For manufactured mounting systems, fill out information on the mounting system below: a.Mounting System Manufacturer ___________Product Name and Model#________________________________ b.Total Weight of PV Modules and Rails ___________lbs c.Total Number of Attachment Points____________ d.Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e.Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f.Total Surface Area of PV Modules (square feet)_________________ ft2 g.Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1.PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2.The PV array is composed of 4 series strings or less per inverter. 3.The total inverter capacity has a continuous ac power output 13,440 Watts or less 4.The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5.One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 5514 W Rhonda Ave11/27/2024 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Micro-Inverter Site Plan             5514 W Rhonda Ave11/27/2024 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Micro-Inverter Electrical Diagram Contractor Name, Address and Phone:One-Line Standard Electrical Diagram for Micro-Inverter PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.1a SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A SAME SAME CONDUIT SIZE N/A N/A N/A SAME SAME DESCRIPTION PV DC or AC MODULE DC/AC INVERTER (MICRO) J-BOX (IF USED) PV ARRAY AC COMB. PANEL (IF USED) GEN METER (IF USED) AC DISCONNECT (IF USED) SERVICE PANEL TAG 1 2 3 4 5 6 7 8 PART NUMBER NOTES FOR UNUSED MODULES PUT "N/A” in BLANK ABOVE 1 1 3 2 3 EQUIPMENT SCHEDULE 2 _____ MICRO-INVERTERS IN BRANCH- CIRCUIT MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 6 7 8 5 4 5 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ MICRO-INVERTERS IN BRANCH- CIRCUIT 5514 W Rhonda Ave11/27/2024 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Contractor Name, Address and Phone:Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.2a SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THEREQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO-INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAREXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULESWITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE.b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULESWITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE®REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) No sign necessary since 690.51 marking on PV module covers needed information AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Notes for Micro-Inverter Electrical Diagram 5514 W Rhonda Ave11/27/2024 PV-1 COVER SHEET VICINITY MAP METER NUMBER: 222013-507784 AHJ CA-CITY OF SANTA ANA UTILITY SOUTHERN CALIFORNIA EDISON CO 5514 RHONDA AVENUE, SANTA ANA, CA 92703 NEW PHOTOVOLTAIC SYSTEM 12.150kW DC / 9.750kW AC / 11.012kW CEC AC CODES AND STANDARDS CALIFORNIA ADMINISTRATIVE CODE ELECTRIC CODE: CEC 2022 FIRE CODE: CFC 2022 BUILDING CODE: CBC 2022 RESIDENTIAL CODE: CRC 2022 WIND SPEED:110 MPH SNOW LOAD: 0 PSF SCOPE OF WORK (N) 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM (30) SEG SOLAR SEG-405-BMD-HV (405W) MODULE (30) ENPHASE IQ8M-72-M-US (240V) MICROINVERTER (1) ENPHASE IQ COMBINER 4 LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM 1025263 LICENSE NO C-10 CLASSIFICATION ECLE T IR C AHSEPTXEN T NIA ROFIETA OF C LA S I RO R C ONT CLA TCA ELECTR I SED NEC L I VICTOR ISAAC NUNEZ SHEET CATALOG PV-1 COVER SHEET PV-1.1 GENERAL NOTES PV-2 SITE PLAN PV-3 MOUNTING DETAILS-1 PV-3.1 MOUNTING DETAILS-2 PV-3.2 STRUCTURAL DETAILS PV-4 SINGLE LINE DIAGRAM PV-4.1 ELECTRICAL CALCULATIONS PV-4.2 EQUIPMENT ELEVATION VIEW PV-5 PLACARDS PV-5.1 PROPOSED EQUIPMENT LAYOUT SS SPEC SHEETS Structural Only 10/18/2024 5514 W Rhonda Ave11/27/2024 PV-1.1 GENERAL NOTES NOTES: 1. MODULES ARE LISTED UNDER UL 1703 / UL 61730 AND CONFORM TO THE STANDARDS. 2. INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 3. DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM. ACTUAL SITE CONDITIONS MAY VARY. 4. WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT SHALL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. 5. ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL / SERVICE EQUIPMENT. 6. ALL CONDUCTORS SHALL BE 600V, 90°C STANDARD COPPER UNLESS OTHERWISE NOTED. 7. WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 8. THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM UTILITY IS RECEIVED. 9. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. 10. PV ARRAY COMBINER / JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING. 11. RACKING SYSTEM SHALL BE LISTED TO UL 2703. 12. FIRE RATING OF EXISTING ROOF ASSEMBLY SHALL BE MAINTAINED WITH ADDITION OF PHOTOVOLTAIC SYSTEM. LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM Structural Only 10/18/2024 5514 W Rhonda Ave11/27/2024 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 5514 RHONA AVE SANTAN ANA CA 92703 CARLEY RAYMOND 661-878-7576 09/09/2024 craymond@nextphaseelect.com NEXT PHASE ELECTRIC 1025263 5514 W Rhonda Ave11/27/2024 TO: CITY OF SANTA ANA RE: 5514 RHONDA AVE SANTA ANA, CA 92703 DATE: 09/6/2024 To whom it may concern: This is to inform you that my contract with ____________________________ is void and cancelled as they went out of business. I will be moving forward with Next Phase Electric Contractor License #1025263 for my home improvement contract. I approve of cancelling the existing permit and approving Next Phase Electric to proceed with my project. Thanks, and best regards, __________________________________ Name __________________________________ Signature AMERICAN SOLAR ADVANTAGE Zoho Sign Document ID: 30204908-LWMACE5NKSG6SLHUM3VBJ-93XT7LE-NACEN-7V1E_SK 5514 W Rhonda Ave11/27/2024 Generated on Sep 6, 2024 22:15 P DT Document ID :30204908-LWMAC E5NKSG6SLHUM3V BJ-93XT7LE-NAC EN-7V 1E_SK Document Name :LETTER OF C A NCELLATION TO A HJ H TRIN H Sent by :Carley Raym ond <c raym ond@nextphaseel ect.com > Organiz ation :N ext P hase Elec tri c Sent on :Sep 6, 2024 08:21 PDT Signers :1 Completed on :Sep 6, 2024 22:15 PDT Receives a copy :0 Sign order :Sequential Approvers :0 N o. of documents :1 Summary Recipients Certificate of Completion Signer H IEP TRIN H al ex.luong.0712@ gmai l.com Emailed on :Sep 6, 2024 08:21 P DT Accessed from :172.58.114.117 Viewed on :Sep 6, 2024 22:13 P DT Device used :Mobi le Terms agreed on :Sep 6, 2024 22:13 PDT Authentication type :None Signed on :Sep 6, 2024 22:15 P DT Signature 5514 W Rhonda Ave11/27/2024 Legal Disclosure ELECTRONIC RECORD AND SIGNATURE DISCLOSURE Please read the fol lowing i nform ati on c arefully. By c li c king the 'I agree' button, you agree that you have r evi ewed the followi ng term s and condi ti ons and c onsent to transact busi ness el ectronical ly usi ng Zoho Si gn electronic signatur e system . If you do not agree to these terms, do not cl ick the 'I agree' button. Electr onic docume nts Please note that Next Phase El ectric ("we", "us" or "Company") wi ll send all docum ents el ectronical ly to you to the em ail addr ess that you have given us during the c ourse of the busi ness rel ati onship unl ess you tel l us otherwise in acc ordance wi th the procedure explai ned herei n. Onc e you si gn a doc ument el ectronical ly, we wil l send a P DF version of the docum ent to you. Re quest for pape r copie s You have the ri ght to request paper c opies of these doc um ents sent to you elec troni cal ly from j abel@ nextphaseel ec t.com . A lternati vely, you also have the ability to download and print these docum ents sent to you el ectronical ly, and r e-upl oad a sc anned c opy of the pr inted and physical ly si gned doc um ents. If you, however, wish to request paper copi es of these docum ents sent to you el ectronically, you c an write back to the sender. Withdr awing y our consent A t any point i n tim e during the course of our business relationship, you have the ri ght to withdraw your consent to rec eive docum ents i n el ectronic format. If you wish to withdr aw your consent, you can decl ine to si gn a docum ent that we have sent to you and send an em ail to jabel @nextphaseelect.com informi ng us that you wi sh to recei ve doc uments onl y i n paper form at. Upon request from you, we wil l stop sending doc um ents using Zoho Sign el ectronic si gnature system . To advise Ne xt Phase Electr ic of your ne w email address If you need to change the emai l address that you use to recei ve noti c es and discl osures from us, write to us at j abel@ nextphaseel ec t.com Sy stem requir eme nts C om patibl e wi th recent ver si ons of popular browsers suc h as Chrom e, Fi refox, Safar i, and Internet Explorer. Zoho Sign i s also avai lable on i OS and A ndroid devi ces. 5514 W Rhonda Ave11/27/2024 MODULE SPEC SHEET SS LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM 5514 W Rhonda Ave11/27/2024 MICROINVERTER SPEC SHEET SS LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM 5514 W Rhonda Ave11/27/2024 SS COMBINER BOX SPEC SHEET LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM 5514 W Rhonda Ave11/27/2024 MOUNT SPEC SHEET SS LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM 5514 W Rhonda Ave11/27/2024 RAIL SPEC SHEET SS LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM 5514 W Rhonda Ave11/27/2024 5514 W Rhonda Ave11/27/2024 5514 W Rhonda Ave11/27/2024 t. (415) 805.7000 38 Fountain Square Plaza Cincinnati, OH 45263 dividendfinance.com All lending is originated by Fifth Third Bank, National Association. Member FDIC. Equal Housing Lender. For solar and certain home improvement loans, Fifth Third Bank does business under the trade name Dividend. October 29, 2024 To whom it may concern, Dividend Solar Finance LLC, the loan provider for Hiep Trinh, authorizes Next Phase Electric to complete the interconnection process for the solar system located at 5514 Rhonda Avenue. The original installer, American Solar Advnatage, is out of business and unable to complete this interconnection for the customer. This letter serves as confirmation that Next Phase Electric is completing the approval and interconnection process for this solar system. This process includes obtaining permits, completing inspections, and submitting interconnection paperwork. The system and electrical work was completed at its current state by American Solar Advantage, Next Phase Electric will complete remediation if needed for inspections. Hiep Trinh 5514 Rhonda Avenue Santa Ana, CA 92703 Regards, The Dividend Team 5514 W Rhonda Ave11/27/2024 MSPACCB JB C C C C C C C C C B B B BBBBBBB A A A A A A A A A A A SCALE:1/16" = 1'-0" PV-2 SITE PLAN (N) UTILITY METER WITH MAIN SERVICE PANEL (EXTERIOR) (UNDER PATIO) SCOPE OF WORK (N) 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM (30) SEG SOLAR SEG-405-BMD-HV (405W) MODULE (30) ENPHASE IQ8M-72-M-US (240V) MICROINVERTER (1) ENPHASE IQ COMBINER 4 TOTAL ARRAY AREA = 630.44 SQ.FT TOTAL ROOF AREA = 3002 SQ.FT % ARRAY AREA IN ROOF = 21% LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM (N) ENPHASE IQ COMBINER 4 (EXTERIOR) (UNDER PATIO) (N) AC DISCONNECT (EXTERIOR) (UNDER PATIO) (N) CONDUIT RUN (N) JUNCTION BOX NEMA 4X RATED (N) (30) SEG SOLAR SEG-405-BMD-HV (405W) MODULES WITH ENPHASE IQ8M-72-M-US (240V) MICROINVERTER UNDER EACH MODULE (N) PHOTOVOLTAIC ARRAY ON MP-01 (N) PHOTOVOLTAIC ARRAY ON MP-03 (N) PHOTOVOLTAIC ARRAY ON MP-02 (N) PHOTOVOLTAIC ARRAY ON MP-04 (N) PHOTOVOLTAIC ARRAY ON MP-05 RHONDA AVENUE DR I V E W A Y 114'-11" 126' 66'-1" 26'-1" 7'-3" 5'-5" 67'-9" (E) DETACHED STRUCTURE (E) RESIDENCE (E) GATE (E) FENCE LEGEND JB SETBACK PROPERTY LINE FENCE AND GATE LINE JUNCTION BOX VENT & ATTIC FAN (ROOF OBSTRUCTION) AC AC DISCONNECT CB COMBINER BOX MSP UTILITY METER WITH MAIN SERVICE PANEL STRING CONFIGURATION BRANCH DETAILS A 11 MICROINVERTERS B 10 MICROINVERTERS C 9 MICROINVERTERS (E) GATE RAPID SHUTDOWN COMPLIANT SYSTEM 27'-2" Structural Only 10/18/2024 5514 W Rhonda Ave11/27/2024 (N) ENPHASE IQ COMBINER 4 (EXTERIOR) (UNDER PATIO) (E) UTILITY METER WITH MAIN SERVICE PANEL (EXTERIOR) (UNDER PATIO) M ENPHASE (N) AC DISCONNECT (EXTERIOR) (UNDER PATIO) SOUTH EXTERIOR WALL ELEVATION BACKYARD (E) GRADE (N) EMT AC CONDUIT FROM ROOF (E) WINDOW (E) WINDOW BACKYARD PV-4.2 LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM DIMENSIONS OF THE EQUIPMENT: (H X W X D) COMBINER BOX: 19.5" X 14.75" X 6.63" AC DISCONNECT: 19.25" X 9.13" X 7.38" SOUTH EXTERIOR WALL ELEVATION SCALE:1/2" = 1'-0" 4'-9"3'-9"4' 6" 1' EQUIPMENT ELEVATION VIEW 5514 W Rhonda Ave11/27/2024 MSPACCB PV-5.1 PROPOSED EQUIPMENT LAYOUT LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM **THIS SHEET FOR FIELD USE ONLY, NOT REQUIRED FOR PERMITTING** NAME: SIGNATURE:DATE: MICROINVERTER STICKERS A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 (N) UTILITY METER WITH MAIN SERVICE PANEL (EXTERIOR) (UNDER PATIO) (N) ENPHASE IQ COMBINER 4 (EXTERIOR) (UNDER PATIO) (N) AC DISCONNECT (EXTERIOR) (UNDER PATIO) (N) PV ARRAY RAPID SHUTDOWN COMPLIANT SYSTEM B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 C1 C2 C3 C4 C5 C6 C7 C8 C9 5514 W Rhonda Ave11/27/2024 PV-3 MOUNTING DETAILS-1 WIND SPEED: 110 MPH AND SNOW LOAD: 0 PSF S.NO AZIMUTH PITCH NO. OF MODULES ARRAY AREA (SQ.FT)ROOF TYPE ATTACHMENT ATTACHMENT QUANTITY ROOF EXPOSURE FRAME TYPE FRAME SIZE FRAME SPACING MAX ATTACHMENT SPACING MAX OVER HANG MP-01 180°18°9 189.13 COMPOSITION SHINGLE SNAPNRACK SPEEDSEAL FOOT 20 ATTIC RAFTERS 2" X 4"24" O.C.4'-0"1'-6" MP-02 0°18°6 126.08 COMPOSITION SHINGLE SNAPNRACK SPEEDSEAL FOOT 12 ATTIC RAFTERS 2" X 4"24" O.C.4'-0"1'-6" MP-03 90°18°4 84.05 COMPOSITION SHINGLE SNAPNRACK SPEEDSEAL FOOT 10 ATTIC RAFTERS 2" X 4"24" O.C.4'-0"1'-6" MP-04 270°18°7 147.1 COMPOSITION SHINGLE SNAPNRACK SPEEDSEAL FOOT 20 ATTIC RAFTERS 2" X 4"24" O.C.4'-0"1'-6" MP-05 90°18°4 84.05 COMPOSITION SHINGLE SNAPNRACK SPEEDSEAL FOOT 12 ATTIC RAFTERS 2" X 4"24" O.C.4'-0"1'-6" LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM Structural Only 10/18/2024 5514 W Rhonda Ave11/27/2024 C C C C C C C C C B B B BBBBBBB A A A A A A A A A A A SCALE:1/8" = 1'-0" PV-3.1 MOUNTING DETAILS-2 LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM NOTE: PENETRATIONS ARE NON-STAGGERED 8'-8" 31'-10" 8'-10" 2'-6"5'-4"3'-2" 2'-3"7'-1"3'-1" 8' 12'-10" 9'-11" 9'-5" 22'-4"10'-4" 8'-4" 5'-4" 2'-1" 9'-2" 14'-11" 6' 1'-7"5'-4"2" 13'-10"26'-1"13'-3" 2'-1" 8'-11" 3'-3" 4' 1'-6" 1'-6" 3'3' 3' 3' 1'-6" 1'-6" 3' 1'-6" 1'-6" 1'-6" 1'-6" 1'-6" 1'-6" 1'-6" 1'-6" (N) ARRAY MP-01 (N) ARRAY MP-02 (N) ARRAY MP-03 (N) ARRAY MP-04 (N) ARRAY MP-05 (N) ALUMINUM RAILS (E) 2" X 4" RAFTERS @ 24" O.C. SPACING LEGEND SETBACK RAIL ATTACHMENT VENT & ATTIC FAN (ROOF OBSTRUCTION) ROOF FRAME MODULE 3' 3' Structural Only 10/18/2024 5514 W Rhonda Ave11/27/2024 PV-3.2 STRUCTURAL DETAILS STRUCTURAL NOTES 1. ALL SOLAR PANEL COMPONENTS SHALL BE INSTALLED PER THE MANUFACTURER'S APPROVED INSTALLATION SPECIFICATIONS. 2. THE EXISTING BUILDING'S STRUCTURE SHALL BE VERIFIED AS PROPERLY CONSTRUCTED AND MAINTAINED IN GOOD CONDITION. NO ALLOWANCE HAS BEEN MADE FOR ANY EXISTING DEFICIENCY IN DESIGN, MATERIAL, CONSTRUCTION, OR LACK OF MAINTENANCE FOR THE EXISTING STRUCTURE OR PROPOSED EQUIPMENT. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, PROPER FIT, AND CLEARANCES IN THE FIELD. 3. IF ANY CONDITION THROUGHOUT THE ASSOCIATED REPORT OR PERMIT DRAWINGS IS NOT REPRESENTED ON-SITE, CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD (EOR) OF ANY DISCREPANCIES AND RECEIVE WRITTEN APPROVAL FROM THE EOR BEFORE PROCEEDING WITH INSTALLATION. 4. MISCELLANEOUS ITEMS NOT EXPLICITLY NAMED & SHOWN IN THESE DRAWINGS HAVE NOT BEEN DESIGNED. IT IS RECOMMENDED THAT MATERIAL OF SUITABLE SIZE & STRENGTH BE OBTAINED FROM A REPUTABLE MANUFACTURER FOR MISCELLANEOUS ITEMS. 5. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLETE, SEAL, & WATERPROOF ROOFTOP PENETRATIONS FOR SOLAR RACKING. 6. CONTRACTOR TO PROVIDE MINIMUM 1/4" GAP BETWEEN ALL SOLAR PANELS. 7. PROJECT WINDSPEED IS BASIC WIND SPEED PER CODE UNLESS NOTED OTHERWISE. DEAD LOAD CALCULATIONS BOM QUANTITY LBS/UNIT TOTAL WEIGHT (LBS) MODULES 30 47.39 1421.7 MID-CLAMP 44 0.17 7.48 END-CLAMP 32 0.3 9.6 RAIL LENGTH 264 0.42 110.88 SPLICE BAR 10 0.52 5.2 SNAPNRACK SPEEDSEAL FOOT 74 0.45 33.3 MICROINVERTER 30 2.43 72.9 TOTAL WEIGHT OF THE SYSTEM (LBS)1661.06 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)630.44 WEIGHT PER SQ. FT.(LBS)2.63 WEIGHT PER PENETRATION (LBS)22.44 SCALE: NTS (N) STAINLESS STEEL 5/16" LAG BOLT MIN. 2.5" EMBEDMENT PILOT HOLE REQUIRED (E) 2" X 4" RAFTERS @ 24" O.C. SPACING (N) SNAPNRACK ULTRA RAIL UR-40 (E) ROOF DECKING(N) SNAPNRACK SPEEDSEAL FOOT (E) COMPOSITION SHINGLE ROOF MEMBRANE (N) SNAPNRACK SPEEDSEAL FOOT (E) 2" X 4" RAFTERS @ 24" O.C. SPACING (N) SOLAR MODULE 6" MAX LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM Structural Only 10/18/2024 5514 W Rhonda Ave11/27/2024 MSPACCB 5514 RHONDA AVENUE, SANTA ANA, CA 92703 PV-5 PLACARDS ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION PV COMBINER BOX [To be used when inverter is ungrounded] WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING LABEL LOCATION AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: CEC 690.13 SOLAR DISCONNECT LABEL LOCATION AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: CEC 690.13(B) ! ! SYSTEM UTILIZES MICROINVERTERS LOCATED UNDER EACH SOLAR MODULE LABEL LOCATION POINT OF INTERCONNECTION PER CODE: CEC 705.12(B)(3-4) AND 690.59 WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM ! LABEL LOCATION POINT OF INTERCONNECTION PER CODE: CEC 705.12(B)(3)(2) WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVER-CURRENT DEVICE RATED AC OPERATING CURRENT AC NOMINAL OPERATING VOLTAGE 40.50 240 PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH AMPS AC VAC LABEL LOCATION AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: CEC 690.54 LABEL LOCATION CONDUIT, PV COMBINER BOX PER CODE: CEC 690.31(D)(2) WARNING:PHOTOVOLTAIC POWER SOURCE LABEL LOCATION PV COMBINER BOX, JUNCTION BOX (ROOF), AC DISCONNECT WARNING-ELECTRIC SHOCK HAZARD NO USER SERVICEABLE PARTS INSIDE CONTACT AUTHORIZED SERVICE PROVIDE FOR ASSISTANCE NOTES 1.PLACARDS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705, UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS. 2.PLACARDS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B) AS REQUIRED AND SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS. 3.PLACARDS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD. 4.PLACARDS SHALL BE SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE HANDWRITTEN. 5.PLACARDS SHALL NOT COVER EXISTING MANUFACTURER LABELS. 6.WARNING SIGNAGE TEXT SHALL BE MINIMUM 3/8" TALL. POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN !!CAUTION:MULTIPLE SOURCES OF POWER LABEL LOCATION SERVICE PANEL PER CODE: CEC 705.10 LABEL LOCATION AC DISCONNECT, PV COMBINER BOX PER CODE: CEC 690.56(C)(2) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: CEC 690.56(C) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRICPV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM (N) UTILITY METER WITH MAIN SERVICE PANEL (EXTERIOR) (UNDER PATIO) (N) ENPHASE IQ COMBINER 4 (EXTERIOR) (UNDER PATIO) (N) AC DISCONNECT (EXTERIOR) (UNDER PATIO) (N) PV ARRAY RAPID SHUTDOWN COMPLIANT SYSTEM 5514 W Rhonda Ave11/27/2024 ENPHASE IQ COMBINER WITH IQ GATEWAY X-IQ-AM1-240-4, 120/240V, NEMA 3R, INSTALL 20A 2P PV BREAKER 15A 2P GATEWAY BREAKER (ONLY FOR SOLAR, NO LOADS TO BE ADDED) 15A/2P 20A/2P 20A/2P 20A/2P (3) (1) (N) ENPHASE IQ COMBINER 4 33 (ROOF EQUIPMENT)(GROUND LEVEL EQUIPMENT) (EXTERIOR) (N) 60A AC DISCONNECT AC DISCONNECT NON FUSED 60A, 120/240V, 2P, VISIBLE, LOCKABLE, LOAD BREAK RATED, ACCESSIBLE 24/7, NEMA 3R (1) BRANCH OF (11) MICROINVERTER (1) BRANCH OF (10) MICROINVERTER (1) BRANCH OF (9) MICROINVERTER (N) JUNCTION BOX NEMA 4X RATED JUNCTION BOX (N) (30) SEG SOLAR SEG-405-BMD-HV (405W) MODULE WITH (N) (30) ENPHASE IQ8M-72-M-US (240V) MICROINVERTER 21 (N) ENPHASE IQ8M-72-M-US (240V) MICROINVERTER PER MODULE (N) SURGE PROTECTIVE DEVICE M METER: SOUTHERN CALIFORNIA EDISON CO 222013-507784 (N) 120/240V 1PH 60HZ (N) 225A END FED MAIN SERVICE PANEL (N ) 2 0 0 A M A I N BR E A K E R PV BREAKER AT THE OPPOSITE END OF BUSBAR (N) 60A 2P PV BREAKER UTILITY GRID (N) GROUNDING ELECTRODE, MIN 5/8" x 8' LONG Cu GROUND ROD INSTALLED IN ACCORDANCE WITH CEC 250.53 4 (OVER HEAD SERVICE) (2) 2/0 AWG THHN/THWN-2, Cu (1) 2/0 AWG THHN/THWN-2, Cu (UNDER PATIO)(EXTERIOR) (UNDER PATIO) (EXTERIOR) (UNDER PATIO) PV-4 MICROINVERTER SPECIFICATIONS MODEL ENPHASE IQ8M-72-M-US (240V) POWER RATING 325W MAX OUTPUT CURRENT 1.35A CEC WEIGHTED EFFICIENCY 97.5% MAX NO OF MICRO INVERTERS/BRANCH 11 MAX DC VOLTAGE 60V MODULE SPECIFICATIONS MODEL SEG SOLAR SEG-405-BMD-HV (405W) MODULE POWER @ STC 405W OPEN CIRCUIT VOLTAGE:Voc 37.22V MAX POWER VOLTAGE:Vmp 30.93V SHORT CIRCUIT CURRENT:Isc 13.7A MAX POWER CURRENT:Imp 13.1A TEMPERATURE COEFFICIENT:Voc -0.27%/°C MODULE DIMENSIONS: L x W x H 67.79" x 44.64" x 1.18" SINGLE LINE DIAGRAM LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM 1025263 LICENSE NO C-10 CLASSIFICATION ECLE T IR C AHSEPTXEN T NIA ROFIETA OF C LA S I RO R C ONT CLA TCA ELECTR I SED NEC L I VICTOR ISAAC NUNEZ TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG ENPHASE Q CABLE PER BRANCH CIRCUIT NONE (1) 12 AWG THHN/THWN-2, Cu, EGC 2 3/4" EMT (6) 10 AWG THHN/THWN-2, Cu NONE (1) 12 AWG THHN/THWN-2, Cu, EGC 3 3/4" EMT (2) 6 AWG THHN/THWN-2, Cu (1) 6 AWG THHN/THWN-2, Cu (1) 10 AWG THHN/THWN-2, Cu, EGC 4 NONE (1) 6 AWG BARE COPPER, GEC CONDUCTOR SCHEDULE NOTE: 1. MICROINVERTERS ARE RAPID SHUTDOWN COMPLIANT AS PER CEC 690.12. 2. KNIFE BLADE AC DISCONNECT SHALL BE INSTALLED WITH PV SYSTEM. 3. REPLACE EXISTING MAIN SERVICE PANEL WITH NEW 225A / 200A MAIN SERVICE PANEL. 4. SURGE PROTECTION SHALL BE INSTALLED WITH THE NEW MAIN SERVICE PANEL IN ACCORDANCE WITH CEC 230.67 5. THE MAIN PANEL IS UNDERGROUND SERVICE WITH 2/0 AWG THHN/THWN-2, Cu PER CEC 310.12. 5514 W Rhonda Ave11/27/2024 PV-4.1 ELECTRICAL CALCULATIONS ALLOWABLE BACKFEED: MAIN PANEL RATING = 225A MAIN BREAKER RATING = 200A 120% RULE: = (MAIN PANEL RATING * 1.2) - MAIN BREAKER RATING = (225A * 1.2) - 200A = 270A - 200A = 70A ALLOWABLE BACKFEED = 70A INVERTER OVERCURRENT PROTECTION: INVERTER OVERCURRENT PROTECTION = (MICROINVERTER O/P CURRENT * # OF MICROINVERTERS) * CONTINUOUS LOAD (1.25) = (1.35 * 30) * 1.25 = 40.50 * 1.25 = 50.62A PV OVERCURRENT PROTECTION = 60A ≥ 50.62A ALLOWABLE BACKFEED 70A ≥ 60A PV OVERCURRENT PROTECTION THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(3)(2) REQUIREMENTS. OCPD CALCULATION AMBIENT TEMPERATURE @ 32°C WIRE SIZE CALCULATIONS = 61.1A = 50.62A = 26.32A = 18.56A = 23.5A = 18.56A TAG 1: (AC) REQUIRED CONDUCTOR AMPACITY (1.35 * 11 * 1.25) CORRECTED AMPACITY CALCULATION (0.94 * 1 * 25) 18.56A < 23.5A (#12 AWG ENPHASE Q CABLE) TAG 2: (AC) REQUIRED CONDUCTOR AMPACITY (1.35 * 11 * 1.25) CORRECTED AMPACITY CALCULATION (0.94 * 0.8 * 35) 18.56A < 26.32A (3/4" EMT, #10 AWG THHN/THWN-2, Cu) TAG 3: (AC) REQUIRED CONDUCTOR AMPACITY (1.35 * 30 * 1.25) CORRECTED AMPACITY CALCULATION (0.94 * 1 * 65) 50.62A < 61.1A (3/4" EMT, #6 AWG THHN/THWN-2, Cu) ELECTRICAL NOTES 1.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER CEC 310.10(D). 2.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER CEC 310.10(C). 3.MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 4.ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 5.BREAKER/FUSE SIZES PER CEC 240. 6.AC EQUIPMENT GROUNDING CONDUCTOR SIZED PER CEC 250.122. 7.AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON CEC 310.15(B)(1). 8.MAX. SYSTEM VOLTAGE COEFFICIENT IS FROM MODULE MANUFACTURER OR CEC 690.7 WHEN MANUFACTURER COEFFICIENT UNAVAILABLE. 9.CONDUCTORS ARE SIZED PER CEC TABLE 310.16. 10. CONDUIT SHALL BE INSTALLED MINIMUM 7/8" FROM ROOF SURFACE. AC WIRE SIZING CALCULATIONS BASED ON FOLLOWING EQUATIONS REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT * #OF INVERTERS = MAX CURRENT PER 690.8(A)(1)(e) * 125% = MAX CURRENT PER 690.8(B)(1) CORRECTED AMPACITY CALCULATIONS: DERATED CONDUCTOR AMPACITY PER 690.8(B)(2) = AMPACITY * TEMPERATURE DERATE FACTOR * CONDUIT FILL DERATE DERATED CONDUCTOR AMPACITY CHECK : MAX CURRENT PER 690.8(B)(1) < DERATED CONDUCTOR AMPACITY LICENSE TYPE: C-10 NEXT PHASE ELECTRIC APN: 09920301 PHONE NUMBER: (661) 878-7576 ADDRESS: 5409 ALDRIN COURT, BAKERSFIELD, CA 93313 ADDRESS: 5514 RHONDA AVENUE, SANTA ANA, CA 92703 COORDINATES: 33.750842, -117.941808 CONTRACTOR INFORMATION NAME: HIEP TRINH CUSTOMER INFORMATION PROJECT ID AUR-1002094 DATE 10/3/2024 CREATED BY SSB SIGNATURE LICENSE NUMBER: 1025263 12.150kW DC / 9.750kW AC / 11.012kW CEC AC ROOF MOUNT PV SYSTEM 5514 W Rhonda Ave11/27/2024 Generated on N ov 19, 2024 17:10 PST Document ID :30204908-Y9U4LCQJI-4C FU0Y_QJ1V9GYHMWUNTNA 0P N_CBAB0UK Document Name :LETTER OF C A NCELLATION TO A HJ H TRIN H 2 Sent by :Carley Raym ond <c raym ond@nextphaseel ect.com > Organiz ation :N ext P hase Elec tri c Sent on :Nov 19, 2024 16:03 P ST Signers :1 Completed on :Nov 19, 2024 17:10 P ST Receives a copy :0 Sign order :Sequential Approvers :0 N o. of documents :1 Witnesses :0 Summary Recipients Certificate of Completion Signer H IEP TRIN H al ex.luong.0712@ gmai l.com Emailed on :Nov 19, 2024 16:03 PST Accessed from :172.58.115.196 Viewed on :N ov 19, 2024 17:09 PST Device used :Mobi le Terms agreed on :Nov 19, 2024 17:09 P ST Authentication type :None Signed on :Nov 19, 2024 17:10 PST Signature 5514 W Rhonda Ave11/27/2024 Legal Disclosure ELECTRONIC RECORD AND SIGNATURE DISCLOSURE Please read the fol lowing i nform ati on c arefully. By c li c king the 'I agree' button, you agree that you have r evi ewed the followi ng term s and condi ti ons and c onsent to transact busi ness el ectronical ly usi ng Zoho Si gn electronic signatur e system . If you do not agree to these terms, do not cl ick the 'I agree' button. Electr onic docume nts Please note that Next Phase El ectric ("we", "us" or "Company") wi ll send all docum ents el ectronical ly to you to the em ail addr ess that you have given us during the c ourse of the busi ness rel ati onship unl ess you tel l us otherwise in acc ordance wi th the procedure explai ned herei n. Onc e you si gn a doc ument el ectronical ly, we wil l send a P DF version of the docum ent to you. Re quest for pape r copie s You have the ri ght to request paper c opies of these doc um ents sent to you elec troni cal ly from j abel@ nextphaseel ec t.com . A lternati vely, you also have the ability to download and print these docum ents sent to you el ectronical ly, and r e-upl oad a sc anned c opy of the pr inted and physical ly si gned doc um ents. If you, however, wish to request paper copi es of these docum ents sent to you el ectronically, you c an write back to the sender. Withdr awing y our consent A t any point i n tim e during the course of our business relationship, you have the ri ght to withdraw your consent to rec eive docum ents i n el ectronic format. If you wish to withdr aw your consent, you can decl ine to si gn a docum ent that we have sent to you and send an em ail to jabel @nextphaseelect.com informi ng us that you wi sh to recei ve doc uments onl y i n paper form at. Upon request from you, we wil l stop sending doc um ents using Zoho Sign el ectronic si gnature system . To advise Ne xt Phase Electr ic of your ne w email address If you need to change the emai l address that you use to recei ve noti c es and discl osures from us, write to us at j abel@ nextphaseel ec t.com Sy stem requir eme nts C om patibl e wi th recent ver si ons of popular browsers suc h as Chrom e, Fi refox, Safar i, and Internet Explorer. Zoho Sign i s also avai lable on i OS and A ndroid devi ces. 5514 W Rhonda Ave11/27/2024 TO: CITY OF SANTA ANA RE: 5514 RHONDA AVE SANTA ANA, CA 92703 DATE: 11/19/2024 To whom it may concern: This is to inform you that my contract with ____________________________ is void and cancelled as they went out of business. I will be moving forward with Next Phase Electric Contractor License #1025263 for my home improvement contract. I approve of cancelling any existing permits and approving Next Phase Electric to proceed with my project to install solar panels, pull permits and finish inspections. Thanks, and Best regards, __________________________________ Name __________________________________ Signature AMERICAN SOLAR ADVANTAGE Zoho Sign Document ID: 30204908-Y9U4LCQJI-4CFU0Y_QJ1V9GYHMWUNTNA0PN_CBAB0UK 5514 W Rhonda Ave11/27/2024