HomeMy WebLinkAbout3009 S Daimler St - PlanBLDG #101120498 ELECT #20183770 PLUMB #30147661 MECH #40139420 APPROVALS: PLNG - F. Arias BLDG - A. So POLICE - B. Martin PW - Y. Soto MECH - T. Luka ELECT - M. Smith 3009 S Daimler St 11/18/2024 A0.2 GENERAL NOTES GENERAL NOTES: JOB SITE NOTES: VENTILATION NOTES: DRAWING NOTES: INTERIOR / EXTERIOR NOTES: GENERAL PROJECT NOTES FINISH NOTES POWER & SIGNAL NOTES DEMOLITION NOTES DOOR NOTES CEILING NOTESPARTITION PLAN NOTES GLAZING NOTESMISCELLANEOUS NOTES FIRE AUTHORITY NOTES REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 3009 S Daimler St 11/18/2024 A0.3a ACCESSIBILITY NOTES “ ” “” “” DIVISION 2: SCOPING REQUIREMENTS DIVISION 2: (continued)DIVISION 2: (continued)DIVISION 2: (continued)DIVISION 2: (continued)DIVISION 2: (continued) REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 3009 S Daimler St 11/18/2024 A0.3b ACCESSIBILITY NOTES DIVISION 3: BUILDING BLOCKS DIVISION 3: BUILDING BLOCKS (continued)DIVISION 4: ACCESSIBLE ROUTES DIVISION 4: ACCESSIBLE ROUTES (continued) “ ” ’ DIVISION 2: (continued)DIVISION 2: (continued) REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 3009 S Daimler St 11/18/2024 A0.3c ACCESSIBILITY NOTES DIVISION 5: GENERAL SITE & BLDG. ELEMENTS “” DIVISION 4: ACCESSIBLE ROUTES (continued)DIVISION 4: ACCESSIBLE ROUTES (continued)DIVISION 4: ACCESSIBLE ROUTES (continued) “” “” “” “” “” “” “” “”“” “” “” �� “– ” – �� “ ” “” DIVISION 4: ACCESSIBLE ROUTES (continued)DIVISION 4: ACCESSIBLE ROUTES (continued) REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 3009 S Daimler St 11/18/2024 A0.3d ACCESSIBILITY NOTES DIVISION 7: COMM. ELEMENTS & FEATURESDIVISION 6: (continued)DIVISION 6: (continued)DIVISION 6: (continued) ’ ’ “” “” “” DIVISION 6: PLUMB'G ELEMENTS & FACILITIESDIVISION 5: (continued) REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 3009 S Daimler St 11/18/2024 A0.3e ACCESSIBILITY NOTES “” DIV. 8: SPECIAL ROOMS, SPACES, & ELEMENTSDIVISION 7: (continued)DIVISION 7: (continued)DIVISION 8: (continued) × DIVISION 7: (continued) “” “” “” “” “” “” DIVISION 7: (continued) REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 3009 S Daimler St 11/18/2024 A0.3f ACCESSIBILITY NOTES ’ ’ DIVISION 9: BUILT-IN ELEMENTS CHAPTER 10 SECTION 1009 CHAPTER 10 SECTION 1009 (continued)DIVISION 8: (continued) “” “” “” REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 3009 S Daimler St 11/18/2024 ACCESSIBLE RESTROOM SIGNAGE ACCESSIBLE TOILET ACCESSIBLE LAVATORY ACCESSIBLE URINAL ACCESSIBLE DRINKING FOUNTAIN 10 5 2 8 7 9 A0.4 ACCESSIBILITY DETAILS HEIGHT REQUIREMENT LEGEND 6 TYP. CLEARANCE AT DOOR PULL SIDE PUSH SIDE 15 14 12 13 1116TYP. TACTILE SIGN INSTALLATION TACTILE "EXIT" SIGN TACTILE "TO EXIT" SIGN TACTILE "EXIT ROUTE" SIGN TACTILE "EXIT STAIR DOWN" SIGNACCESSIBLE SIGNAGE @ ENTRY TYPICAL PARKING STALLS PARKING NO INT. SYMBOL OF ACCESSIBLE - ISA 17 18 "NO PARKING" PAVEMENT MARKING 19 ACCESSIBLE SIGNS OR VAN ACCESSIBLE SIGNAGE PRECAST CONCRETE WHEELSTOP ACCESSIBLE CURB RAMP A - CURB RAMPS AT ACCESSIBLE PARKING AREAS 20 22 23 24 25 OBSTRUCTED HIGH FORWARD REACH REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 3009 S Daimler St 11/18/2024 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE NONRESIDENTIAL MANDATORY MEASURES, SHEET 1 CHAPTER 5 NONRESIDENTIAL MANDATORY MEASURES SECTION 5.101 GENERAL 5.101.1 SCOPE The provisions of this chapter outline planning, design and development methods that include environmentally responsible site selection, building design, building siting and development to protect, restore and enhance the environmental quality of the site and respect the integrity of adjacent properties. DIVISION 5.1 PLANNING AND DESIGN SECTION 5.102 DEFINITIONS 5.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) CUTOFF LUMINAIRES. Luminaires whose light distribution is such that the candela per 1000 lamp lumens does not numerically exceed 25 (2.5 percent) at an angle of 90 degrees above nadir, and 100 (10 percent) at a vertical angle of 80 degrees above nadir. This applies to all lateral angles around the luminaire. LOW-EMITTING AND FUEL EFFICIENT VEHICLES. Eligible vehicles are limited to the following: 1. Zero emission vehicle (ZEV), enhanced advanced technology PZEV (enhanced AT ZEV) or transitional zero emission vehicles (TZEV) regulated under CCR, Title 13, Section 1962. 2. High-efficiency vehicles, regulated by U.S. EPA, bearing a fuel economy and greenhouse gas rating od 9 oe 10 as regulated under 40 CFR Section 600 Subpart D. NEIGHBORHOOD ELECTRIC VEHICLE (NEV). A motor vehicle that meets the definition of "low-speed vehicle" either in Section 385.5 of the Vehicle Code or in 49CFR571.500 (as it existed on July 1, 2000), and is certified to zero-emission vehicle standards. TENANT-OCCUPANTS. Building occupants who inhabit a building during its normal hours of operation as permanent occupants, such as employees, as distinguished from customers and other transient visitors. VANPOOL VEHICLE. Eligible vehicles are limited to any motor vehicle, other than a motortruck or truck tractor, designed for carrying more than 10 but not more than 15 persons including the driver, which is maintained and used primarily for the nonprofit work-related transportation of adults for the purpose of ridesharing. Note: Source: Vehicle Code, Division 1, Section 668 ZEV. Any vehicle certified to zero-emission standards. SECTION 5.106 SITE DEVELOPMENT 5.106.1 STORM WATER POLLUTION PREVENTION FOR PROJECTS THAT DISTURB LESS THAN ONE ACRE OF LAND. Newly constructed projects and additions which disturb less than one acre of land, and are not part of a larger common plan of development or sale, shall prevent the pollution of storm water runoff from the construction activities through one or more of the following measures: 5.106.1.1 Local ordinance. Comply with a lawfully enacted storm water management and/or erosion control ordinance. 5.106.1.2 Best Management Practices (BMPs). Prevent the loss of soil through wind or water erosion by implementing an effective combination of erosion and sediment control and good housekeeping BMPs. 1. Soil loss BMPs that should be considered for implementation as appropriate for each project include, but are not limited to, the following: a. Scheduling construction activity during dry weather, when possible. b. Preservation of natural features, vegetation, soil, and buffers around surface waters. c. Drainage swales or lined ditches to control stormwater flow. d. Mulching or hydroseeding to stabilize disturbed soils. e. Erosion control to protect slopes. f. Protection of storm drain inlets (gravel bags or catch basin inserts). g. Perimeter sediment control (perimeter silt fence, fiber rolls). h. Sediment trap or sediment basin to retain sediment on site. i. Stabilized construction exits. j. Wind erosion control. k. Other soil loss BMPs acceptable to the enforcing agency. 2. Good housekeeping BMPs to manage construction equipment, materials, non-stormwater discharges and wastes that should be considered for implementation as appropriate for each project include, but are not limited to, the following: a. Dewatering activities. b. Material handling and waste management. c. Building materials stockpile management. d. Management of washout areas (concrete, paints, stucco, etc.). e. Control of vehicle/equipment fueling to contractor's staging area. f. Vehicle and equipment cleaning performed off site. g Spill prevention and control. h. Other housekeeping BMPs acceptable to the enforcing agency. ABBREVIATION DEFINITIONS: HCD Department of Housing and Community Development BSC California Building Standards Commission DSA-SS Division of the State Architect, Structural Safety OSHPD Office of Statewide Health Planning and Development LR Low Rise HR High Rise AA Additions and Alterations N New CHAPTER 3 GREEN BUILDING SECTION 301 GENERAL 301.1 SCOPE. Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code. Voluntary green building measures are also included in the application checklists and may be included in the design and construction of structures covered by this code, but are not required unless adopted by a city, county, or city and county as specified in Section 101.7. 301.3 NONRESIDENTIAL ADDITIONS AND ALTERATIONS. [BSC-CG] The provisions of individual sections of Chapter 5 apply to newly constructed buildings, building additions of 1,000 square feet or greater, and/or building alterations with a permit valuation of $200,000 or above (for occupancies within the authority of California Building Standards Commission). Code sections relevant to additions and alterations shall only apply to the portions of the building being added or altered within the scope of the permitted work. A code section will be designated by a banner to indicate where the code section only applies to newly constructed buildings [N] or to additions and/or alterations [A]. When the code section applies to both, no banner will be used. 301.3.1 Nonresidential additions and alterations that cause updates to plumbing fixtures only: Note: On and after January 1, 2014, certain commercial real property, as defined in Civil Code Section 1101.3, shall have its noncompliant plumbing fixtures replaced with appropriate water-conserving plumbing fixtures under specific circumstances. See Civil Code Section 1101.1 et seq. for definitions, types of commercial real property affected, effective dates, circumstances necessitating replacement of noncompliant plumbing fixtures, and duties and responsibilities for ensuring compliance. 301.3.2 Waste Diversion. The requirements of Section 5.408 shall be required for additions and alterations whenever a permit is required for work. 301.4 PUBLIC SCHOOLS AND COMMUNITY COLLEGES. (see GBSC) 301.5 HEALTH FACILITIES. (see GBSC) SECTION 302 MIXED OCCUPANCY BUILDINGS 302.1 MIXED OCCUPANCY BUILDINGS. In mixed occupancy buildings, each portion of a building shall comply with the specific green building measures applicable to each specific occupancy. SECTION 303 PHASED PROJECTS 303.1 PHASED PROJECTS. For shell buildings and others constructed for future tenant improvements, only those code measures relevant to the building components and systems considered to be new construction (or newly constructed) shall apply. 303.1.1 Initial Tenant improvements. The provisions of this code shall apply only to the initial tenant improvements to a project. Subsequent tenant improvements shall comply with the scoping provisions in Section 301.3 non-residential additions and alterations. DIVISION 5.2 ENERGY EFFICIENCY SECTION 5.201 GENERAL 5.201.1 Scope [BSC-CG]. California Energy Code [DSA-SS]. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory building standards. DIVISION 5.3 WATER EFFICIENCY AND CONSERVATION SECTION 5.301 GENERAL 5.301.1 Scope. The provisions of this chapter shall establish the means of conserving water use indoors, outdoors and in wastewater conveyance. SECTION 5.302 DEFINITIONS 5.302.1 Definitions. The following terms are defined in Chapter 2 (and are included here for reference) EVAPOTRANSPIRATION ADJUSTMENT FACTOR (ETAF) [DSA-SS]. An adjustment factor when applied to reference evapotranspiration that adjusts for plant factors and irrigation efficiency, which ae two major influences on the amount of water that needs to be applied to the landscape. FOOTPRINT AREA [DSA-SS]. The total area of the furthest exterior wall of the structure projected to natural grade, not including exterior areas such as stairs, covered walkways, patios and decks. METERING FAUCET. A self-closing faucet that dispenses a specific volume of water for each actuation cycle. The volume or cycle duration can be fixed or adjustable. GRAYWATER. Pursuant to Health and Safety Code Section 17922.12, "graywater" means untreated wastewater that has not been contaminated by any toilet discharge, has not been affected by infectious, contaminated, or unhealthy bodily wastes, and does not present a threat from contamination by unhealthful processing, manufacturing, or operating wastes. "Graywater" includes, but is not limited to wastewater from bathtubs, showers, bathroom washbasins, clothes washing machines and laundry tubs, but does not include waste water from kitchen sinks or dishwashers. MODEL WATER EFFICIENT LANDSCAPE ORDINANCE (MWELO). The California ordinance regulating landscape design, installation and maintenance practices that will ensure commercial, multifamily and other developer installed landscapes greater than 2500 square feet meet an irrigation water budget developed based on landscaped area and climatological parameters. MODEL WATER EFFICIENT LANDSCAPE ORDINANCE (MWELO). [HCD] The California model ordinance (California Code of Regulations, Title 23, Division 2, Chapter 2.7), regulating landscape design, installation and maintenance practices. Local agencies are required to adopt the updated MWELO, or adopt a local ordinance at least as effective as the MWELO. POTABLE WATER. Water that is drinkable and meets the U.S. Environmental Protection Agency (EPA) Drinking Water Standards. See definition in the California Plumbing Code, Part 5. POTABLE WATER. [HCD] Water that is satisfactory for drinking, culinary, and domestic purposes, and meets the U.S. Environmental Protection Agency (EPA) Drinking Water Standards and the requirements of the Health Authority Having Jurisdiction. RECYCLED WATER. Water which, as a result of treatment of waste, is suitable for a direct beneficial use or a controlled use that would not otherwise occur [Water Code Section 13050 (n)]. Simply put, recycled water is water treated to remove waste matter attaining a quality that is suitable to use the water again. SUBMETER. [HCD 1] A secondary device beyond a meter that measures water consumption of an individual rental unit within a multiunit residential structure or mixed-use residential and commercial structure. (See Civic Code Section 1954.202 (g) and Water code Section 517 for additional details.) WATER BUDGET. Is the estimated total landscape irrigation water use which shall not exceed the maximum applied water allowance calculated in accordance with the Department of Water Resources Model Efficient Landscape Ordinance (MWELO). 5.106.5.3 Electric vehicle (EV) charging. [N] Construction to provide electric vehicle infrastructure and facilitate electric vehicle charging shall comply with Section 5.106.5.3.1 and shall be provided in accordance with regulations in the California Building Code and the California Electrical Code. Exceptions: 1.On a case-by-case basis where the local enforcing agency has determined compliance with this section is not feasible based upon one of the following conditions: a.Where there is no local utility power supply b.Where the local utility is unable to supply adequate power. c.Where there is evidence suitable to the local enforcement agency substantiating the local utility infrastructure design requirements, directly related to the implementation of Section 5.106.5.3, may adversely impact the construction cost of the project. 2. Parking spaces accessible only by automated mechanical car parking systems are not required to comply with this code section 5.106.5.3.1 EV capable spaces. [N] EV capable spaces shall be provided in accordance with Table 5.106.5.3.1 and the following requirements: 1.Raceways complying with the California Electrical Code and no less that 1-inch (25 mm) diameter shall be provided and shall originate at a service panel or a subpanel(s) serving the area, and shall terminate in close proximity to the proposed location of the EV capable and into a suitable listed cabinet, box,enclosure or equivalent. A common raceway may be used to serve multiple EV charging spaces. 2.A service panel or subpanel (s) shall be provided with panel space and electrical load capacity for a dedicated 208/240 volt, 40-ampere minimum branch circuit for each EV capable space, with delivery of 30-ampere minimum to an installed EVSE at each EVCS. 3.The electrical system and any on-site distribution transformers shall have sufficient capacity to supply full rated amperage at each EV capable space. 4.The service panel or subpanel circuit directory shall identify the reserved overcurrent protective devices space(s) as "EV CAPABLE". The raceway termination location shall be permanently and visibly marked as "EV CAPABLE." Note: A parking space served by electric vehicle supply equipment or designed as a future EV charging space shall count as at least one standard automobile parking space only for the purpose of complying with any applicable minimum parking space requirements established by an enforcement agency. See vehicle Code Section 22511.2 for further details. 5.106.4.1.2 Long-term bicycle parking. For new buildings with tenant spaces that have 10 or more tenant-occupants, provide secure bicycle parking for 5 percent of the tenant-occupant vehicular parking spaces with a minimum of one bicycle parking facility. 5.106.4.1.3 For additions or alterations that add 10 or more tenant-occupant vehicular parking spaces, provide secure bicycle parking for 5 percent of the tenant vehicular parking spaces being added, with a minimum of one bicycle parking facility. 5.106.4.1.4 For new shell buildings in phased projects provide secure bicycle parking for 5 percent of the anticipated tenant-occupant vehicular parking spaces with a minimum of one bicycle parking facility. 5.106.4.1.5 Acceptable bicycle parking facility for Sections 5.106.4.1.2, 5.106.4.1.3, and 5.106.4.1.4 shall be convenient from the street and shall meet one of the following: 1. Covered, lockable enclosures with permanently anchored racks for bicycles; 2. Lockable bicycle rooms with permanently anchored racks; or 3. Lockable, permanently anchored bicycle lockers. Note: Additional information on recommended bicycle accommodations may be obtained from Sacramento Area Bicycle Advocates. 5.106.4.2 Bicycle parking. [DSA-SS] For public schools and community colleges, comply with Sections 5.106.4.2.1 and 5.106.4.2.2 5.106.4.2.1 Student bicycle parking. Provide permanently anchored bicycle racks conveniently accessed with a minimum of four two-bike capacity racks per new building. 5.106.4.2.2 Staff bicycle parking. Provide permanent, secure bicycle parking conveniently accessed with a minimum of two staff bicycle parking spaces per new building. Acceptable bicycle parking facilities shall be convenient from the street or staff parking area and shall meet one of the following: 1. Covered, lockable enclosures with permanently anchored racks for bicycles; 2. Lockable bicycle rooms with permanently anchored racks; or 3. Lockable, permanently anchored bicycle lockers. 5.106.4 BICYCLE PARKING. For buildings within the authority of California Building Standards Commission as specified in Section 103, comply with Section 5.106.4.1. For buildings within the authority of the Division of the State Architect pursuant to Section 105, comply with Section 5.106.4.2 5.106.4.1 Bicycle parking. [BSC-CG] Comply with Sections 5.106.4.1.1 and 5.106.4.1.2; or meet the applicable local ordinance, whichever is stricter. 5.106.4.1.1 Short-term bicycle parking. If the new project or an addition or alteration is anticipated to generate visitor traffic, provide permanently anchored bicycle racks within 200 feet of the visitors' entrance, readily visible to passers-by, for 5% of new visitor motorized vehicle parking spaces being added, with a minimum of one two-bike capacity rack. Exception: Additions or alterations which add nine or less visitor vehicular parking spaces. 5.106.5.3.3 Use of automatic load management systems (ALMS). ALMS shall be permitted for EVCS. When ALMS is installed, the required electrical load capacity specified in Section 5.106.5.3.1 for each EVCS may be reduced when serviced by an EVSE controlled by an ALMS. Each EVSE controlled by an ALMS shall deliver a minimum 30 amperes to an EV when charging one vehicle and shall deliver a minimum 3.3 kW while simultaneously charging multiple EVs. 5.106.5.3.4 Accessible EVCS. When EVSE is installed, accessible EVSC shall be provided in accordance with the California Building Code, Chapter 11B, Section 11B-228.3. Note: For EVCS signs, refer to Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s). 5.106.5.4 Electric Vehicle (EV) charging: medium-duty and heavy-duty. [N] Construction shall comply with section 5.106.5.4.1 to facilitate future installation of electric vehicle supply equipment (EVSE). Construction for warehouses, grocery stores and retail stores with planned off-street loading spaces shall also comply with Section 5.106.5.4.1 for future installation of medium- and heavy-duty EVSE. Exceptions: 1.On a case-by-case basis where the local enforcing agency has determined compliance with this section is not feasible based upon one of the following conditions: a.Where there is no local utility power supply. b.Where the local utility is unable to supply adequate power. c.Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements, directly related to the implementation of Section 5.106.5.3, may adversely impact the construction cost of the project. When EVSE(s) is/are installed, it shall be in accordance with the California Building Code, the California Electrical Code and as follows: 5.106.5.4.1 Electric vehicle charging readiness requirements for warehouse, grocery stores and retail stores with planned off-street loading spaces. [N]In order to avoid future demolition when adding EV charging supply and distribution equipment, spare raceways(s) or busway(s) and adequate capacity for transformers(s), service panels(s) or subpanel(s) shall be installed at the time of construction in accordance with the California Electrical Code. Construction plans and specifications shall include but are not limited to, the following: 1.The transformer, main service equipment and subpanel shall meet the minimum power requirement in Table 5.106.5.4.1 to accommodate the dedicated branch circuits for the future installation of EVSE. 2.The construction documents shall indicate on or more location(s) convenient to the planned offstreet loading space(s) reserved for medium-and heavy-duty ZEV charging cabinets and charging dispensers, and a pathway reserved for routing of conduit from the termination of the raceway(s) or busway(s) to the charging cabinet(s) and dispenser(s) as shown in Table 5.106.5.4.1 3.Raceway(s) or busway(s) originating at a main service panel or a subpanel(s) serving the area where potential future medium-and heavy-duty EVSE will be located and shall terminate in close proximity to the potential future location of the charging equipments for medium- and heavy-duty vehicles. 4.The raceway(s) or busway(s) shall be sufficient size to carry the minimum additional system load to the future location of the charging for medium- and heavy-duty ZEVs as shown in Table 5.106.5.4.1. TABLE 5.106.5.3.1 TOTAL NUMBER OF ACTUAL PARKING SPACES NUMBER OF REQUIRED EV CAPABLE SPACES NUMBER OF EVCS (EV CAPABLE SPACES PROVIDED WITH EVSE)^2 0-9 0 0 10-25 2 0 26-50 8 2 51-75 13 3 76-100 17 4 101-150 25 6 151-200 35 9 201 AND OVER 20% of total¹25% of EV capable spaces¹ 5.106.8 LIGHT POLLUTION REDUCTION. [N]. l Outdoor lighting systems shall be designed and installed to comply with the following: 1.The minimum requirements in the California Energy Code for Lighting Zones 0-4 as defined in Chapter 10, Section 10-114 of the California Administrative Code; and 2.Backlight (B) ratings as defined in IES TM-15-11 (shown in Table A-1 in Chapter 8); 3.Uplight and Glare ratings as defined in California Energy Code (shown in Tables 130.2-A and 130.2-B in Chapter 8) and 4.Allowable BUG ratings not exceeding those shown in Table 5.106.8, [N] or Comply with a local ordinance lawfully enacted pursuant to Section 101.7, whichever is more stringent. Exceptions: [N] 1. Luminaires that qualify as exceptions in Sections 130.2 (b) and 140.7 of the California Energy Code. 2. Emergency lighting. 3. Building facade meeting the requirements in Table 140.7-B of the California Energy Code, Part 6. 4. Custom lighting features as allowed by the local enforcing agency, as permitted by Section 101.8 Alternate materials, designs and methods of construction. 5. Luminaires with less than 6,200 initial luminaire lumens. TABLE 5.106.8 [N] MAXIMUM ALLOWABLE BACKLIGHT, UPLIGHT AND GLARE (BUG) RATINGS 1,2 ALLOWABLE RATING LIGHTING ZONE LZ0 LIGHTING ZONE LZ1 LIGHTING ZONE LZ2 LIGHTING ZONE LZ3 LIGHTING ZONE LZ4 MAXIMUM ALLOWABLE BACKLIGHT RATING 3 Luminaire greater than 2 mounting heights (MH) from property line N/A No Limit No Limit No Limit No Limit Luminaire back hemisphere is 1-2 MH from property line N/A B2 B3 B4 B4 Luminaire back hemisphere is 0.5-1 MH from property line N/A B1 B2 B3 B3 Luminaire back hemisphere is less than 0.5 MH from property line N/A B0 B0 B1 B2 MAXIMUM ALLOWABLE UPLIGHT RATING (U) For area lighting 3 N/A U0 U0 U0 U0 For all other outdoor lighting,including decorative luminaires N/A U1 U2 U3 UR 5.106.2 STORMWATER POLLUTION PREVENTION FOR PROJECTS THAT DISTURB ONE OR MORE ACRES OF LAND. Comply with all lawfully enacted stormwater discharge regulations for projects that (1) disturb one acre or more of land, or (2) disturb less than one acre of land but are part of a larger common plan of development sale. Note: Projects that (1) disturb one acre or more of land, or (2) disturb less than one acre of land but are part of the larger common plan of development or sale must comply with the post-construction requirements detailed in the applicable National Pollutant Discharge Elimination System (NPDES) General permit for Stormwater Discharges Associated with Construction and Land Disturbance Activities issued by the State Water Resources Control Board or the Lahontan Regional Water Quality Control Board (for projects in the Lake Tahoe Hydrologic Unit). The NPDES permits require postconstruction runoff (post-project hydrology) to match the preconstruction runoff (pre-project hydrology) with the installation of postconstruction stormwater management measures. The NPDES permits emphasize runoff reduction through on-site stormwater use, interception, evapotranspiration, and infiltration through nonstructural controls, such as Low Impact Development (LID) practices, and conversation design measures. Stormwater volume that cannot be addressed using nonstructural practices is required to be captured in structural practices and be approved by the enforcing agency. Refer to the current applicable permits on the State Water Resources Control Board website at: www.waterboards.ca.gov/constructionstormwater. Consideration to the stormwater runoff management measures should be given during the initial design process for appropriate integration into site development. 1.Where there is insufficient electrical supply. 2.The number of required EVCS (EV capable spaces provided with EVSE) in column 3 count towards the total number of required EV capable spaces shown in column 2. 5.106.5.3.2 Electric vehicle charging stations (EVCS) EV capable spaces shall be provided with EVSE to create EVCS in the number indicated in Table 5.106.5.3.1. The EVCS required by Table 5.106.5.3.1 may be provided with EVSE in any combination of Level 2 and Direct Current Fast Charging (DCFC), except that at least one Level 2 EVSE shall be provided. One EV charger with multiple connectors capable of charging multiple EVs simultaneously shall be permitted if the electrical load capacity required by Section 5.106.5.3.1 for each EV capable space is accumulatively supplied to the EV charger. The installation of each DCFC EVSE shall be permitted to reduce the minimum number of required EV capable spaces without EVSE by five and reduce proportionally the required electrical load capacity to the service panel or subpanel. 5.106.8.1 Facing- Backlight Luminaries within 2MH of a property line shall be oriented so that the nearest property line is behind the fixture, and shall comply with the backlight rating specified in Table 5.106.8 based on the lighting zone and distance to the nearest point of that property line. Exception: Corners. If two property lines (or two segments of the same property line) have equidistant point to the luminaire, then the luminaire may be oriented so that the intersection of the two lines (the corner) is directly behind the luminaire. The luminaire shall still use the distance to the nearest points(s) on the property lines to determine the required backlight rating. 5.106.8.2 Facing-Glare. For luminaires covered by 5.106.8.1, if a property line also exists within or extends into the front hemisphere within 2MH of the luminaire then the luminaire shall comply with the more stringent glare rating specified in Table 5.106.8 based on the lighting zone and distance to the nearest point on the nearest property line within the front hemisphere. Note: [N] 1.See also California Building Code, Chapter 12, Section 1205.6 for college campus lighting requirements for parking facilities and walkways. 2.Refer to Chapter 8 (Compliance Forms, Worksheets and Reference Material) for IES TM-15-11 Table A-1, California Energy Code Tables 130.2-A and 130.2-B. 3. Refer to the California Building Code for requirements for additions and alterations. 5.106.10 GRADING AND PAVING. Construction plans shall indicate how site grading or a drainage system will manage all surface water flows to keep water from entering buildings. Examples of methods to manage surface water include, but are not limited to, the following: 1.Swales. 2.Water collection and disposal systems. 3.French drains. 4.Water retention gardens. 5.Other water measures which keep surface water away from buildings and aid in groundwater recharge. Exception: Additions and alterations not altering the drainage path. 5.106.12 SHADE TREES [DSA-SS]. Shade Trees shall be planted to comply with Sections 5.106.12.1, 5.106.12.2, and 5.106.12.3. Percentages shown shall be measured at noon on the summer solstice. Landscape irrigation necessary to establish and maintain tree health shall comply with Section 5.304.6. 5.106.12.1 Surface parking areas. Shade tree plantings, minimum #10 container size or equal, shall be installed to provide shade over 50 percent of the parking area within 15 years. Exceptions: Surface parking area covered by solar photovoltaic shade structures with roofing materials that comply with Table A5.106.11.2.2 in Appendix A5 shall be permitted in whole or in part in lieu of shade tree planting. 5.106.12.2 Landscape areas. Shade tress plantings, minimum #10 container size or equal shall be installed to provide shade of 20% of the landscape area within 15 years. Exceptions: Playfields for organized sport activity are not included in the total area calculation. 5.106.12.3. Hardscape areas. Shade tree plantings, minimum #10 container size or equal shall be installed to provide shade over 20 percent of the hardscape area within 15 years. Exceptions: 1.Walks, hardscape areas covered by solar photovoltaic shade structures or shade structures with roofing materials that comply with Table A5.106.11.2.2 in Appendix A5 shall be permitted in whole or in part in lieu of shade tree planting. 2.Designated and marked play areas of organized sport activity are not included in the total area calculation. TABLE 5.106.5.4.1 RACEWAY CONDUIT AND PANEL POWER REQUIREMENTS FOR MEDIUM- AND HEAVY-DUTY EVSE [N] BUILDING TYPE BUILDING SIZE (SQ. FT.) NUMBER OF OFF-STREET LOADING SPACES ADDITIONAL CAPACITY REQUIRED (KVA) FOR RACEWAY & BUSWAY AND TRANSFORMER & PANEL Grocery 10,000 to 90,000 1 or 2 200 3 or Greater 400 Greater than 90,000 1 or Greater 400 Retail 10,000 to 135,000 1 or 2 200 3 or Greater 400 Greater than 135,000 1 or Greater 400 Warehouse 20,000 to 256,000 1 or 2 200 3 or Greater 400 Greater than 256,000 1 or Greater 400 MAXIMUM ALLOWABLE GLARE RATING 5 (G) MAXIMUM ALLOWABLE GLARE RATING 5 (G)N/A G1 G2 G3 G4 MAXIMUM ALLOWABLE GLARE RATING 5 (G)N/A G0 G1 G1 G2 MAXIMUM ALLOWABLE GLARE RATING 5 (G)N/A G0 G0 G1 G1 MAXIMUM ALLOWABLE GLARE RATING 5 (G)N/A G0 G0 G0 G1 1. IESNA Lighting Zones 0 and 5 are not applicable; refer to Lighting Zones as defined in the California Energy Code and Chapter 10 of the Callifornia Administrative Code. 2. For property lines that abut public walkways, bikeways, plazas and parking lots, the property line may be considered to be 5 feet beyond the actual property line for purpose of determining compliance with this section. For property lines that abut public roadways and public transit corridors, the property line may be considered to be the centerline of the public roadway or public transit corridor for the purpose of determining compliance with this section. 3. General lighting luminaires in areas such as outdoor parking, sales or storage lots shall meet these reduced ratings. Decorative luminaries located in these areas shall meet U-value limits for "all other outdoor lighting" A0.5a CALIFORNIA GREEN BUILDING CODE NOTES REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 3009 S Daimler St 11/18/2024 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE NONRESIDENTIAL MANDATORY MEASURES, SHEET 2 5.303.3 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the following: 5.303.3.1 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Tank-Type toilets. Note: The effective flush volume of dual flush toilets is defined as the composite, average flush volume of two reduced flushes and one full flush. 5.303.3.2 Urinals. 5.303.3.2.1 Wall-mounted Urinals. The effective flush volume of wall-mounted urinals shall not exceed 0.125 gallons per flush. 5.303.3.2.2 Floor-mounted Urinals. The effective flush volume of floor-mounted or other urinals shall not exceed 0.5 gallons per flush. 5.303.3.3 Showerheads. [BSC-CG] 5.303.3.3.1 Single showerhead. Showerheads shall have a maximum flow rate of not more than 1.8 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Showerheads. 5.303.3.3.2 Multiple showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all the showerheads and/or other shower outlets controlled by a single valve shall not exceed 1.8 gallons per minute at 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Note: A hand-held shower shall be considered a showerhead. DIVISION 5.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY SECTION 5.401 GENERAL 5.401.1 SCOPE. The provisions of this chapter shall outline means of achieving material conservation and resource efficiency through protection of buildings from exterior moisture, construction waste diversion, employment of techniques to reduce pollution through recycling of materials, and building commissioning or testing and adjusting. SECTION 5.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING 5.408.1 CONSTRUCTION WASTE MANAGEMENT. Recycle and/or salvage for reuse a minimum of 65% of the non-hazardous construction and demolition waste in accordance with Section 5.408.1.1, 5.408.1.2 or 5.408.1.3; or meet a local construction and demolition waste management ordinance, whichever is more stringent. 5.408.1.1 Construction waste management plan. Where a local jurisdiction does not have a construction and demolition waste management ordinance, submit a construction waste management plan that: 1. Identifies the construction and demolition waste materials to be diverted from disposal by efficient usage, recycling, reuse on the project or salvage for future use or sale. 2. Determines if construction and demolition waste materials will be sorted on-site (source-separated) or bulk mixed (single stream). 3. Identifies diversion facilities where construction and demolition waste material collected will be taken. 4. Specifies that the amount of construction and demolition waste materials diverted shall be calculated by weight or volume, but not by both. 5.408.1.2 Waste Management Company. Utilize a waste management company that can provide verifiable documentation that the percentage of construction and demolition waste material diverted from the landfill complies with this section. Note: The owner or contractor shall make the determination if the construction and demolition waste material will be diverted by a waste management company. Exceptions to Sections 5.408.1.1 and 5.408.1.2: 1. Excavated soil and land-clearing debris. 2. Alternate waste reduction methods developed by working with local agencies if diversion or recycle facilities capable of compliance with this item do not exist. 3. Demolition waste meeting local ordinance or calculated in consideration of local recycling facilities and markets. 5.408.1.3 Waste stream reduction alternative. The combined weight of new construction disposal that does not exceed two pounds per square foot of building area may be deemed to meet the 65% minimum requirement as approved by the enforcing agency. 5.408.1.4 Documentation. Documentation shall be provided to the enforcing agency which demonstrates compliance with Sections 5.408.1.1, through 5.408.1.3. The waste management plan shall be updated as necessary and shall be accessible during construction for examination by the enforcing agency. Notes: 1. Sample forms found in "A Guide to the California Green Building Standards Code (Nonresidential)" located www.dgs.ca.gov/BSC/Resources/Page-Content/Building-Standards-Commission- Resources-List-Folder/CALGreen may be used to assist in documenting compliance with the waste management plan. 2. Mixed construction and demolition debris processors can be located at the California Department of Resources Recycling and Recovery (CalRecycle). 5.408.2 UNIVERSAL WASTE. [A] Additions and alterations to a building or tenant space that meet the scoping provisions in Section 301.3 for nonresidential additions and alterations, shall require verification that Universal Waste items such as fluorescent lamps and ballast and mercury containing thermostats as well as other California prohibited Universal Waste materials are disposed of properly and are diverted from landfills. A list of prohibited Universal Waste materials shall be included in the construction documents. Note: Refer to the Universal Waste Rule link at: http://www.dtsc.ca.gov/universalwaste/ 5.408.3 EXCAVATED SOIL AND LAND CLEARING DEBRIS. 100 percent of trees, stumps, rocks and associated vegetation and soils resulting primarily from land clearing shall be reused or recycled. For a phased project, such material may be stockpiled on site until the storage site is developed. Exception: Reuse, either on or off-site, of vegetation or soil contaminated by disease or pest infestation. Notes: 1. If contamination by disease or pest infestation is suspected, contact the County Agricultural Commissioner and follow its direction for recycling or disposal of the material. 2. For a map of know pest and/or disease quarantine zones, consult with the California Department of Food and Agriculture. (www.cdfa.ca.gov) DIVISION 5.5 ENVIRONMENTAL QUALITY SECTION 5.501 GENERAL 5.501.1 SCOPE. The provisions of this chapter shall outline means of reducing the quantity of air contaminants that are odorous, irritating, and/or harmful to the comfort and well-being of a building's installers, occupants and neighbors. SECTION 5.502 DEFINITIONS 5.502.1 DEFINITIONS. The following terms are defined in Chapter 2 (and are included here for reference) ARTERIAL HIGHWAY. A general term denoting a highway primarily for through traffic usually on a continuous route. A-WEIGHTED SOUND LEVEL (dBA). The sound pressure level in decibels as measured on a sound level meter using the internationally standardized A-weighting filter or as computed from sound spectral data to which A-weighting adjustments have been made. 1 BTU/HOUR. British thermal units per hour, also referred to as Btu. The amount of heat required to raise one pound of water one degree Fahrenheit per hour, a common measure of heat transfer rate. A ton of refrigeration is 12,000 Btu, the amount of heat required to melt a ton (2,000 pounds) of ice at 320 Fahrenheit. COMMUNITY NOISE EQUIVALENT LEVEL (CNEL). A metric similar to the day-night average sound level (Ldn), except that a 5 decibel adjustment is added to the equivalent continuous sound exposure level for evening hours (7pm to 10pm) in addition to the 10 dB nighttime adjustment used in the Ldn. COMPOSITE WOOD PRODUCTS. Composite wood products include hardwood plywood, particleboard and medium density fiberboard. “Composite wood products” does not include hardboard, structural plywood, structural panels, structural composite lumber, oriented strand board, glued laminated timber, timber, prefabricated wood I–joists or finger–jointed lumber, all as specified in California Code of Regulations (CCR), Title 17, Section 93120.1(a). Note: See CCR, Title 17, Section 93120.1. DAY-NIGHT AVERAGE SOUND LEVEL (Ldn). The A-weighted equivalent continuous sound exposure level for a 24-hour period with a 10 dB adjustment added to sound levels occurring during nighttime hours (10p.m. to 7 a.m.). DECIBEL (db). A measure on a logarithmic scale of the magnitude of a particular quantity (such as sound pressure, sound power, sound intensity) with respect to a reference quantity. ELECTRIC VEHICLE (EV). An automotive-type vehicle for on-road use, such as passenger automobiles, buses, trucks, vans, neighborhood electric vehicles, electric motorcycles, and the like, primarily powered by an electric motor that draws current from a rechargeable storage battery, fuel cell, photovoltaic array, or other source of electric current. Plug-in hybrid electric vehicles (PHEV) are considered electric vehicles. For purposes of the California Electrical Code, off-road, self-propoelled electric vehicles, such as industrial trucks, hoists, lifts, transports, golf carts, airline ground support equipment, tractors, boats, and the like, are not included. ELECTRIC VEHICLE CHARGING STATION(S) (EVCSj). One or more spaces intended for charging electric vehicles. ELECTRIC VEHICLE SUPPLY EQUIPMENT (EVSE). The conductors, including the ungrounded, grounded, and equipment grounding conductors and the electric vehicle connectors, attachment plugs, and all other fittings, devices, power outlets, or apparatus installed specifically for the purpose of transferring energy between the premises wiring and the electric vehicle. ENERGY EQUIVALENT (NOISE) LEVEL (Leq). The level of a steady noise which would have the same energy as the fluctuating noise level integrated over the time of period of interest. EXPRESSWAY. An arterial highway for through traffic which may have partial control of access, but which may or may not be divided or have grade separations at intersections. FREEWAY. A divided arterial highway with full control of access and with grade separations at intersections. GLOBAL WARMING POTENTIAL (GWP). The radiative forcing impact of one mass-based unit of a given greenhouse gas relative to an equivalent unit of carbon dioxide over a given period of time. Carbon dioxide is the reference compound with a GWP of one. GLOBAL WARMING POTENTIAL VALUE (GWP VALUE). A 100-year GWP value published by the Intergovernmental Panel on Climate Change (IPCC) in either its Second Assessment Report (SAR) (IPCC, 1995); or its Fourth Assessment A-3 Report (AR4) (IPCC, 2007). The SAR GWP values are found in column "SAR (100-yr)" of Table 2.14.; the AR4 GWP values are found in column "100 yr" of Table 2.14. HIGH-GWP REFRIGERANT. A compound used as a heat transfer fluid or gas that is: (a) a chlorofluorocarbon, a hdrochlorofluorocarbon, a hydrofluorocarbon, a perfluorocarbon, or any compound or blend of compounds, with a GWP value equal to or greater than 150, or (B) any ozone depleting substance as defined in Title 40 of the Code of Federal Regulations, Part 82, sec.82.3 (as amended March 10, 2009). LONG RADIUS ELBOW. Pipe fitting installed between two lengths of pipe or tubing to allow a change of direction, with a radius 1.5 times the pipe diameter. LOW-GWP REFRIGERANT. A compound used as a heat transfer fluid or gas that: (A) has a GWP value less than 150, and (B) is not an ozone depleting substance as defined in Title 40 of the Code of Federal Regulations, Part 82, sec.82.3 (as amended March 10, 2009). MERV. Filter minimum efficiency reporting value, based on ASHRAE 52.2–1999. MAXIMUM INCREMENTAL REACTIVITY (MIR). The maximum change in weight of ozone formed by adding a compound to the "Base REactive Organic Gas (ROG) Mixture" per weight of compound added, expressed to hundreths of a gram (g O3/g ROC). PRODUCT-WEIGHTED MIR (PWMIR). The sum of all weighted-MIR for all ingredients in a product subject to this article. The PWMIR is the total product reactivity expressed to hundredths of a gram of ozone formed per gram of product (excluding container and packaging). PSIG. Pounds per square inch, guage. REACTIVE ORGANIC COMPOUND (ROC). Any compound that has the potential, once emitted, to contribute to ozone formation in the troposphere. SCHRADER ACCESS VALVES. Access fittings with a valve core installed. SHORT RADIUS ELBOW. Pipe fitting installed between two lengths of pipe or tubing to allow a change of direction, with a radius 1.0 times the pipe diameter. SUPERMARKET. For the purposes of Section 5.508.2, a supermarket is any retail food facility with 8,000 square feet or more conditioned area, and that utilizes either refrigerated display cases, or walk-in coolers or freezers connected to remote compressor units or condensing units. VOC. A volatile organic compound broadly defined as a chemical compound based on carbon chains or rings with vapor pressures greater than 0.1 millimeters of mercury at room temperature. These compounds typically contain hydrogen and may contain oxygen, nitrogen and other elements. See CCR Title 17, Section 94508(a) . Note: Where specific regulations are cited from different agencies such as SCAQMD, ARB, etc., the VOC definition included in that specific regulation is the one that prevails for the specific measure in question. SECTION 5.503 FIREPLACES 5.503.1 FIREPLACES. Install only a direct-vent sealed-combustion gas or sealed wood-burning fireplace, or a sealed woodstove or pellet stove, and refer to residential requirements in the California Energy Code, Title 24, Part 6, Subchapter 7, Section 150. Woodstoves, pellet stoves and fireplaces shall comply with applicable local ordinances. 5.503.1.1 Woodstoves. Woodstoves and pellet stoves shall comply with U.S. EPA New Source Performance Standards (NSPS) emission limits as applicable, and shall have a permanent label indicating they are certified to meet the emission limits. SECTION 5.504 POLLUTANT CONTROL 5.504.1 TEMPORARY VENTILATION. The permanent HVAC system shall only be used during construction if necessary to condition the building or areas of addition or alteration within the required temperature range for material and equipment installation. If the HVAC system is used during construction, use return air filters with a Minimum Efficiency Reporting Value (MERV) of 8, based on ASHRAE 52.2-1999, or an average efficiency of 30% based on ASHRAE 52.1-1992 Replace all filters immediately prior to occupancy, or, if the building is occupied during alteration, at the conclusion of construction. 5.504.3 Covering of duct openings and protection of mechanical equipment during construction. At the time of rough installation and during storage on the construction site until final startup of the heating, cooling and ventilation equipment, all duct and other related air distribution component openings shall be covered with tape, plastic, sheetmetal or other methods acceptable to the enforcing agency to reduce the amount of dust, water and debris which may enter the system. 5.410.2.1 Owner's or Owner Representative's Project Requirements (OPR). [N] The expectations and requirements of the building appropriate to its phase shall be documented before the design phase of the project begins. This documentation shall include the following: 1. Environmental and sustainability goals. 2. Building sustainable goals. 3. Indoor environmental quality requirements. 4. Project program, including facility functions and hours of operation, and need for after hours operation. 5. Equipment and systems expectations. 6. Building occupant and operation and maintenance (O&M) personnel expectations. 5.410.2.2 Basis of Design (BOD). [N] A written explanation of how the design of the building systems meets the OPR shall be completed at the design phase of the building project. The Basis of Design document shall cover the following systems: 1. Renewable energy systems. 2. Landscape irrigation systems. 3. Water reuse system. 5.410.2.3 Commissioning plan. [N] Prior to permit issuance a commissioning plan shall be completed to document how the project will be commissioned. The commissioning plan shall include the following: 1. General project information. 2. Commissioning goals. 3. Systems to be commissioned. Plans to test systems and components shall include: a. An explanation of the original design intent. b. Equipment and systems to be tested, including the extent of tests. c. Functions to be tested. d. Conditions under which the test shall be performed. e. Measurable criteria for acceptable performance. 4. Commissioning team information. 5. Commissioning process activities, schedules and responsibilities. Plans for the completion of commissioning shall be included. 5.410.2.4 Functional performance testing. [N] Functional performance tests shall demonstrate the correct installation and operation of each component, system and system-to-system interface in accordance with the approved plans and specifications. Functional performance testing reports shall contain information addressing each of the building components tested, the testing methods utilized, and include any readings and adjustments made. 5.410.2.6 Commissioning report. [N] A report of commissioning process activities undertaken through the design and construction phases of the building project shall be completed and provided to the owner or representative. 5.410.4 TESTING AND ADJUSTING. New buildings less than 10,000 square feet. Testing and adjusting of systems shall be required for new buildings less than 10,000 square feet or new systems to serve an addition or alteration subject to Section 303.1. 5.410.4.2 (Reserved) Note: For energy-related systems under the scope (Section 100) of the California Energy Code, including heating, ventilation, air conditioning (HVAC) systems and controls, indoor lighting system and controls, as well as water heating systems and controls, refer to California Energy Code Section 120.8 for commissioning requirements and Sections 120.5, 120.6, 130.4, and 140.9(b)3 for additional testing requirements of specific systems. 5.410.4.2 Systems. Develop a written plan of procedures for testing and adjusting systems. Systems to be included for testing and adjusting shall include at a minimum, as applicable to the project: 1. Renewable energy systems. 2. Landscape irrigation systems. 3. Water reuse systems. 5.410.4.3 Procedures. Perform testing and adjusting procedures in accordance with manufacturer's specifications and applicable standards on each system. 5.410.4.3.1 HVAC balancing. In addition to testing and adjusting, before a new space-conditioning system serving a building or space is operated for normal use, the system shall be balanced in accordance with the procedures defined by the Testing Adjusting and Balancing Bureau National Standards; the National Environmental Balancing Bureau Procedural Standards; Associated Air Balance Council National Standards or as approved by the enforcing agency. SECTION 5.303 INDOOR WATER USE 5.303.1 METERS. Separate submeters or metering devices shall be installed for the uses described in Sections 503.1.1 and 503.1.2. 5.303.1.1 Buildings in excess of 50,000 square feet. Separate submeters shall be installed as follows: 1. For each individual leased, rented or other tenant space within the building projected to consume more than 100 gal/day (380 L/day), including, but not limited to, spaces used for laundry or cleaners, restaurant or food service, medical or dental office, laboratory, or beauty salon or barber shop. SECTION 5.410 BUILDING MAINTENANCE AND OPERATIONS 5.410.1 RECYCLING BY OCCUPANTS. Provide readily accessible areas that serve the entire building and are identified for the depositing, storage and collection of non-hazardous materials for recycling, including (at a minimum) paper, corrugated cardboard, glass, plastics, organic waste, and metals or meet a lawfully enacted local recycling ordinance, if more restrictive. Exception: Rural jurisdictions that meet and apply for the exemption in Public Resources Code 42649.82 (a)(2)(A) et seq. shall also be exempt from the organic waste portion of this section. 5.410.1.1 Additions. All additions conducted within a 12-month period under single or multiple permits, resulting in an increase of 30% or more in floor area, shall provide recycling areas on site. Exception: Additions within a tenant space resulting in less than a 30% increase in the tenant space floor area. 5.410.1.2 Sample ordinance. Space allocation for recycling areas shall comply with Chapter 18, Part 3, Division 30 of the Public Resources Code. Chapter 18 is known as the California Solid Waste Reuse and Recycling Access Act of 1991 (Act). Note: A sample ordinance for use by local agencies may be found in Appendix A of the document at the CalRecycle’s web site. 5.410.2.5 Documentation and training. [N] A Systems Manual and Systems Operations Training are required, including Occupational Safety and Health Act (OSHA) requirements in California Code of Regulations (CCR), Title 8, Section 5142, and other related regulations. 5.410.2.5.1 Systems manual. [N] Documentation of the operational aspects of the building shall be completed within the systems manual and delivered to the building owner or representative. The systems manual shall include the following: 1. Site information, including facility description, history and current requirements. 2. Site contact information. 3. Basic operations and maintenance, including general site operating procedures, basic troubleshooting, recommended maintenance requirements, site events log. 4. Major systems. 5. Site equipment inventory and maintenance notes. 6. A copy of verifications required by the enforcing agency or this code. 7. Other resources and documentation, if applicable. 5.410.2.5.2 Systems operations training. [N] A program for training of the appropriate maintenance staff for each equipment type and/or system shall be developed and documented in the commissioning report and shall include the following: 1. System/equipment overview (what it is, what it does and with what other systems and/or equipment it interfaces). 2. Review and demonstration of servicing/preventive maintenance. 3. Review of the information in the Systems Manual. 4. Review of the record drawings on the system/equipment. 2. Where separate submeters for individual building tenants are unfeasible, for water supplied to the following subsystems: a. Makeup water for cooling towers where flow through is greater than 500 gpm (30 L/s). b. Makeup water for evaporative coolers greater than 6 gpm (0.04 L/s). c. Steam and hot water boilers with energy input more than 500,000 Btu/h (147 kW). 5.303.1.2 Excess consumption. A separate submeter or metering device shall be provided for any tenant within a new building or within an addition that is projected to consume more than 1,000 gal/day. SECTION 5.304 OUTDOOR WATER USE 5.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. Nonresidential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources' Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent. Notes: 1. The Model Water Efficient Landscape Ordinance (MWELO) is located in the California Code of Regulations, Title 23, Chapter 2.7, Division 2. 2. MWELO and supporting documents, including a water budget calculator, are available at: https://www.water.ca.gov/. 5.304.6 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. For public schools and community colleges, landscape projects as described in Sections 5.304.6.1 and 5.304.6.2 shall comply with the California Department of Water Resources Model Water Efficient Landscape Ordinance (MWELO) commencing with Section 490 of Chapter 2.7, Division 2, Title 23, California Code of Regulations, except that the evapotranspiration adjustment factor (ETAF) shall be 0.65 with an additional water allowance for special landscape areas (SLA) of 0.35. Exception: Any project with an aggregate landscape area of 2,500 square feet or less may comply with the prescriptive measures contained in Appendix D of the MWELO. 5.304.6.1 Newly constructed landscapes. New construction projects with an aggregate landscape area equal to or greater than 500 square feet. 5.304.6.2 Rehabilitated landscapes. Rehabilitated landscape projects with an aggregate landscape area equal to or greater than 1,200 square feet. 5.303.4 COMMERCIAL KITCHEN EQUIPMENT. 5.303.4.1 Food Waste Disposers. Disposers shall either modulate the use of water to no more than 1 gpm when the disposer is not in use (not actively grinding food waste/no-load) or shall automatically shut off after no more than 10 minutes of inactivity. Disposers shall use no more than 8 gpm of water. Note: This code section does not affect local jurisdiction authority to prohibit or require disposer installation. 5.303.5 AREAS OF ADDITION OR ALTERATION. For those occupancies within the authority of the California Building Standards Commission as specified in Section 103, the provisions of Section 5.303.3 and 5.303.4 shall apply to new fixtures in additions or areas of alteration to the building. 5.303.6 STANDARDS FOR PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1701.1 of the California Plumbing Code and in Chapter 6 of this code. SECTION 5.402 DEFINITIONS 5.402.1 DEFINITIONS. The following terms are defined in Chapter 2 (and are included here for reference) ADJUST. To regulate fluid flow rate and air patterns at the terminal equipment, such as to reduce fan speed or adjust a damper. BALANCE. To proportion flows within the distribution system, including sub-mains, branches and terminals, according to design quantities. BUILDING COMMISSIONING. A systematic quality assurance process that spans the entire design and construction process, including verifying and documenting that building systems and components are planned, designed, installed, tested, operated and maintained to meet the owner’s project requirements. ORGANIC WASTE. Food waste, green waste, landscape and pruning wste, nonhazardous wood waste, and food soiled paper waste that is mixed in with food waste. TEST. A procedure to determine quantitative performance of a system or equipment SECTION 5.407 WATER RESISTANCE AND MOISTURE MANAGEMENT 5.407.1 WEATHER PROTECTION. Provide a weather-resistant exterior wall and foundation envelope as required by California Building Code Section 1402.2 (Weather Protection), manufacturer's installation instructions or local ordinance, whichever is more stringent. 5.407.2 MOISTURE CONTROL. Employ moisture control measures by the following methods. 5.407.2.1 Sprinklers. Design and maintain landscape irrigation systems to prevent spray on structures. 5.407.2.2 Entries and openings. Design exterior entries and/or openings subject to foot traffic or wind-driven rain to prevent water intrusion into buildings as follows: 5.407.2.2.1 Exterior door protection. Primary exterior entries shall be covered to prevent water intrusion by using nonabsorbent floor and wall finishes within at least 2 feet around and perpendicular to such openings plus at least one of the following: 1. An installed awning at least 4 feet in depth. 2. The door is protected by a roof overhang at least 4 feet in depth. 3. The door is recessed at least 4 feet. 4. Other methods which provide equivalent protection. 5.407.2.2.2 Flashing. Install flashings integrated with a drainage plane. 5.410.2 COMMISSIONING. [N] New buildings 10,000 square feet and over. For new buildings 10,000 square feet and over, building commissioning shall be included in the design and construction processes of the building project to verify that the building systems and components meet the owner’s or owner representative’s project requirements. Commissioning shall be performed in accordance with this section by trained personnel with experience on projects of comparable size and complexity. For I-occupancies that are not regulated by OSHPD or for I-occupancies and L-occupancies that are not regulated y the California Energy Code Section 100.0 Scope, all requirements in Sections 5.410.2 through 5.410.2.6 shall apply. Note: For energy-related systems under the scope (Section 100) of the California Energy Code, including heating, ventilation, air conditioning (HVAC) systems and controls, indoor lighting systems and controls, as well as water heating systems and controls, refer to California Energy Code Section 120.8 for commissioning requirements Commissioning requirements shall include: 1. Owner’s or Owner representative’s project requirements. 2. Basis of design. 3. Commissioning measures shown in the construction documents. 4. Commissioning plan. 5. Functional performance testing. 6. Documentation and training. 7. Commissioning report. Exceptions: 1. Unconditioned warehouses of any size. 2. Areas less than 10,000 square feet used for offices or other conditioned accessory spaces within unconditioned warehouses. 3. Tenant improvements less than 10,000 square feet as described in Section 303.1.1. 4. Open parking garages of any size, or open parking garage areas, of any size, within a structure. Note: For the purposes of this section, unconditioned shall mean a building, area, or room which does not provide heating and or air conditioning. Informational Notes: 1. IAS AC 476 is an accreditation criteria for organizations providing training and/or certification of commissioning personnel. AC 476 is available to the Authority Having Jurisdiction as a reference for qualifications of commissioning personnel. AC 476 des not certify individuals to conduct functional performance tests or to adjust and balance systems. 2. Functional performance testing for heating, ventilation, air conditioning systems and lighting controls must be performed in compliance with the California Energy Code. 5.410.4.4 Reporting. After completion of testing, adjusting and balancing, provide a final report of testing signed by the individual responsible for performing these services. 5.410.4.5 Operation and maintenance (O & M) manual. Provide the building owner or representative with detailed operating and maintenance instructions and copies of guaranties/warranties for each system. O & M instructions shall be consistent with OSHA requirements in CCR, Title 8, Section 5142, and other related regulations. 5.410.4.5.1 Inspections and reports. Include a copy of all inspection verifications and reports required by the enforcing agency. 5.303.3.4 Faucets and fountains. 5.303.3.4.1 Nonresidential Lavatory faucets. Lavatory faucets shall have a maximum flow rate of not more than 0.5 gallons per minute at 60 psi. 5.303.3.4.2 Kitchen faucets. Kitchen faucets shall have a maximum flow rate of not more than 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. 5.303.3.4.3 Wash fountains. Wash fountains shall have a maximum flow rate of not more than1.8 gallons per minute/20 [rim space (inches) at 60 psi]. 5.303.3.4.4 Metering faucets. Metering faucets shall not deliver more than 0.20 gallons per cycle. 5.303.3.4.5 Metering faucets for wash fountains. Metering faucets for wash fountains shall have a maximum flow rate of not more than 0.20 gallons per minute/20 [rim space (inches) at 60 psi]. Note: Where complying faucets are unavailable, aerators or other means may be used to achieve reduction. 5.303.3.4.6 Pre-rinse spray value When installed, shall meet the requirements in the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Section 1605.1 (h)(4) Table H-2, Section 1605.3 (h)(4)(A), and Section 1607 (d)(7), and shall be equipped with an integral automatic shutoff. FOR REFERENCE ONLY:The following table and code section have been reprinted from the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Section 1605.1 (h)(4) and Section 1605.3 (h)(4)(A). TABLE H-2 STANDARDS FOR COMMERCIAL PRE-RINSE SPRAY VALUES MANUFACTURED ON OR AFTER JANUARY 28, 2019 PRODUCT CLASS [spray force in ounce force (ozf)]MAXIMUM FLOW RATE (gpm) Product Class 1 (≤1.00 Product Class 2 (> 5.0 ozf and ≤1.20 Product Class 3 (> 8.0 ozf)1.28 A0.5b CALIFORNIA GREEN BUILDING CODE NOTES REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 3009 S Daimler St 11/18/2024 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE NONRESIDENTIAL MANDATORY MEASURES, SHEET 3 5.504.4.4.1 Carpet cushion. All carpet cushion installed in the building interior shall meet the requirements of the California Department of Public Health,"Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,"Version 1.2, January 2017 (Emission testing method for California Specifications 01350). See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx#material 5.504.4.4.2 Carpet adhesive. All carpet adhesive shall meet the requirements of Table 5.504.4.1. 5.504.4.5 Composite wood products. Hardwood plywood, particleboard and medium density fiberboard composite wood products used on the interior or exterior of the buildings shall meet the requirements for formaldehyde as specified in ARB's Air Toxics Control Measure (ATCM) for Composite Wood (17 CCR 93120 et seq.). Those materials not exempted under the ATCM must meet the specified emission limits, as shown in Table 5.504.4.5. 5.504.4.5.3 Documentation. Verification of compliance with this section shall be provided as requested by the enforcing agency. Documentation shall include at least one of the following: 1. Product certifications and specifications. 2. Chain of custody certifications. 3. Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR, Title 17, Section 93120, et seq.). 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered Wood Association, the Australian AS/NZS 2269 or European 636 3S standards. 5. Other methods acceptable to the enforcing agency. TABLE 5.504.4.3 - CONT. GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS COATING CATEGORY CURRENT VOC LIMIT SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS)500 HIGH-TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS1 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS, & UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS: CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB & TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & EXEMPT COMPOUNDS 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE. 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEB. 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. TABLE 5.504.4.5 - FORMALDEHYDE LIMITS1 MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 THIN MEDIUM DENSITY FIBERBOARD2 0.13 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIFORNIA CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16 INCHES (8 MM). 5.508.2 Supermarket refrigerant leak reduction. New commercial refrigeration systems shall comply with the provisions of this section when installed in retail food stores 8,000 square feet or more conditioned area, and that utilize either refrigerated display cases, or walk-in coolers or freezers connected to remote compressor units or condensing units. The leak reduction measures apply to refrigeration systems containing high-global-warming potential (high-GWP) refrigerants with a GWP of 150 or greater. New refrigeration systems include both new facilities and the replacement of existing refrigeration systems in existing facilities. Exception: Refrigeration systems containing low-global warming potential (low-GWP) refrigerant with a GWP value less than 150 are not subject to this section. Low-GWP refrigerants are nonozone-depleting refrigerants that include ammonia, carbon dioxide (CO2), and potentially other refrigerants. 5.508.2.1 Refrigerant piping. Piping compliant with the California Mechanical Code shall be installed to be accessible for leak protection and repairs. Piping runs using threaded pipe, copper tubing with an outside diameter (OD) less than 1/4 inch, flared tubing connections and short radius elbows shall not be used in refrigerant systems except as noted below. 5.508.2.1.1 Threaded pipe. Threaded connections are permitted at the compressor rack. 5.508.2.1.2 Copper pipe. Copper tubing with an OD less than 1/4 inch may be used in systems with a refrigerant charge of 5 pounds or less. 5.508.2.1.2.1 Anchorage. One-fouth-inch OD tubing shall be securely clamped to a rigid base to keep vibration levels below 8 mils. 5.508.2.1.3 Flared tubing connections. Double-flared tubing connections may be used for pressure controls, valve pilot lines and oil. Exception: Single-flared tubing connections may be used with a multiring seal coated with industrial sealant suitable for use with refrigerants and tightened in accordance with manufacturer's recommendations. 5.508.2.1.4 Elbows. Short radius elbows are only permitted where space limitations prohibit use of long radius elbows. 5.508.2.2 Valves. Valves Valves and fittings shall comply with the California Mechanical Code and as follows. 5.508.2.2.1 Pressure relief valves. For vessels containing high-GWP refrigerant, a rupture disc shall be installed between the outlet of the vessel and the inlet of the pressure relief valve. 5.508.2.2.1.1 Pressure detection. A pressure gauge, pressure transducer or other device shall be installed in the space between the rupture disc and the relief valve inlet to indicate a disc rupture or discharge of the relief valve. 5.508.2.2.2 Access valves. Only Schrader access valves with a brass or steel body are permitted for use. 5.508.2.2.2.1 Valve caps. For systems with a refrigerant charge of 5 pounds or more, valve caps shall be brass or steel and not plastic. 5.508.2.2.2.2 Seal caps. If designed for it, the cap shall have a neoprene O-ring in place. 5.508.2.2.2.2.1 Chain tethers. Chain tethers to fit ovr the stem are required for valves designed to have seal caps. Exception: Valves with seal caps that are not removed from the valve during stem operation. 5.508.2.3 Refrigerated service cases. Refrigerated service cases holding food products containing vinegar and salt shall have evaporator coils of corrosion-resistant material, such as stainless steel; or be coated to prevent corrosion from these substances. 5.508.2.3.1 Coil coating. Consideration shall be given to the heat transfer efficiency of coil coating to maximize energy efficiency. 5.508.2.4 Refrigerant receivers. Refrigerant receivers with capacities greater than 200 pounds shall be fitted with a device tha indicates the level of refrigerant in the receiver. 5.508.2.5 Pressure testing. The system shall be pressure tested during installation prior to evacuation and charging. 5.508.2.5.1 Minimum pressure. The system shall be charged with regulated dry nitrogen and appropriate tracer gas to bring system pressure up to 300 psig minimum. 5.508.2.5.2 Leaks. Check the system for leaks, repair any leaks, and retest for pressure using the same gauge. 5.508.2.5.3 Allowable pressure change. The system shall stand, unaltered, for 24 hours with no more than a +/- one pound pressure change from 300 psig, measured with the same gauge. 5.508.2.6 Evacuation. The system shall be evacuated after pressure testing and prior to charging. 5.508.2.6.1 First vacuum. Pull a system vacuum down to at least 1000 microns (+/- 50 microns), and hold for 30 minutes. 5.508.2.6.2 Second vacuum. Pull a second system vacuum to a minimum of 500 microns and hold for 30 minutes. 5.508.2.6.3 Third vacuum. Pull a third vacuum down to a minimum of 300 microns, and hold for 24 hours with a maximum drift of 100 microns over a 24-hour period. CHAPTER 7 INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS 702 QUALIFICATIONS 702.1 INSTALLER TRAINING. HVAC system installers shall be trained and certified in the proper installation of HVAC systems including ducts and equipment by a nationally or regionally recognized training or certification program. Uncertified persons may perform HVAC installations when under the direct supervision and responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC systems. Examples of acceptable HVAC training and certification programs include but are not limited to the following: 1. State certified apprenticeship programs. 2. Public utility training programs. 3. Training programs sponsored by trade, labor or statewide energy consulting or verification organizations. 4. Programs sponsored by manufacturing organizations. 5. Other programs acceptable to the enforcing agency. 702.2 SPECIAL INSPECTION [HCD]. When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition to other certifications or qualifications acceptable to the enforcing agency, the following certifications or education may be considered by the enforcing agency when evaluating the qualifications of a special inspector: 1. Certification by a national or regional green building program or standard publisher. 2. Certification by a statewide energy consulting or verification organization, such as HERS raters, building performance contractors, and home energy auditors. 3. Successful completion of a third party apprentice training program in the appropriate trade. 4. Other programs acceptable to the enforcing agency. Notes: 1. Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate homes in California according to the Home Energy Rating System (HERS). [BSC-CG] When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition, the special inspector shall have a certification from a recognized state, national or international association, as determined by the local agency. The area of certification shall be closely related to the primary job function, as determined by the local agency. Note: Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 703 VERIFICATIONS 703.1 DOCUMENTATION. Documentation used to show compliance with this code shall include but is not limited to, construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which demonstrate substantial conformance. When specific documentation or special inspection is necessary to verify compliance, that method of compliance will be specified in the appropriate section or identified applicable checklist. SECTION 5.505 INDOOR MOISTURE CONTROL 5.505.1 INDOOR MOISTURE CONTROL. Buildings shall meet or exceed the provisions of California Building Code, CCR, Title 24, Part 2, Sections 1202 (Ventilation) and Chapter 14 (Exterior Walls). For additional measures, see Section 5.407.2 of this code. SECTION 5.506 INDOOR AIR QUALITY 5.506.1 OUTSIDE AIR DELIVERY. For mechanically or naturally ventilated spaces in buildings, meet the minimum requirements of Section 120.1 (Requirements For Ventilation) of the California Energy Code, or the applicable local code, whichever is more stringent, and Division 1, Chapter 4 of CCR, Title 8. 5.506.2 CARBON DIOXIDE (CO2) MONITORING. For buildings or additions equipped with demand control ventilation, CO2 sensors and ventilation controls shall be specified and installed in accordance with the requirements of the California Energy Code, Section 120(c)(4). 5.506.3 Carbon dioxide (CO2) monitoring in classrooms. (DSA-SS) Each public K-12 school classroom, as listed in Table 120.1-A of the California Energy Code, shall be equipped with a carbon dioxide monitor or sensor that meets the following requirements: 1.The monitor or sensor shall be permanently affixed in a tamper-proof manner in each classroom between 3 and 6 feet (914 mm and 1829 mm) above the floor and at least 5 feet (1524 mm) away from door and operable windows. 2.When the monitor or sensor is not integral to an Energy Management Control System (EMCS), the monitor or sensor shall display the carbon dioxide readings on the device. When the sensor is integral to an EMCS, the carbon dioxide readings shall be available to and regularly monitored by facility personnel. 3.A monitor shall provide notification though a visual indicator on the monitor when the carbon dioxide levels in the classroom have exceeded 1,100ppm. A sensor integral to an EMCS shall provide notification to facility personnel through a visual and/or audible indicator when the carbon dioxide levels in the classroom have exceeded 1,100ppm. 4.The monitor or sensor shall measure carbon dioxide levels at minimum 15- minute intervals and shall maintain a record of previous carbon dioxide measurements of not less than 30 days duration. 5.The monitor or sensor used to measure carbon dioxide levels shall have the capacity to measure carbon dioxide levels with a range of 400ppm to 2000ppm or greater. 6.The monitor or sensor shall be certified by the manufacturer to be accurate within 75ppm at 1,000ppm carbon dioxide concentration and shall be certified by the manufacturer to require calibration no more frequently than once every 5 years. SECTION 5.507 ENVIRONMENTAL COMFORT 5.507.4 ACOUSTICAL CONTROL. Employ building assemblies and components with Sound Transmission Class (STC) values determined in accordance with ASTM E 90 and ASTM E 413, or Outdoor-Indoor Sound Transmission Class (OITC) determined in accordance with ASTM E 1332, using either the prescriptive or performance method in Section 5.507.4.1 or 5.507.4.2. Exception: Buildings with few or no occupants or where occupants are not likely to be affected by exterior noise, as determined by the enforcement authority, such as factories, stadiums, storage, enclosed parking structures and utility buildings. Exception: [DSA-SS] For public schools and community colleges, the requirements of this section and all subsections apply only to new construction. 5.507.4.1 Exterior noise transmission, prescriptive method. Wall and roof-ceiling assemblies exposed to the noise source making up the building or addition envelope or altered envelope shall meet a composite STC rating of at least 50 or a composite OITC rating of no less than 40, with exterior windows of a minimum STC of 40 or OITC of 30 in the following locations: 1. Within the 65 CNEL noise contour of an airport. Exceptions: 1. Ldn or CNEL for military airports shall be determined by the facility Air Installation Compatible Land Use Zone (AICUZ) plan. 2. Ldn or CNEL for other airports and heliports for which a land use plan has not been developed shall be determined by the local general plan noise element. 2. Within the 65 CNEL or Ldn noise contour of a freeway or expressway, railroad, industrial source or fixed-guideway source as determined by the Noise Element of the General Plan. 5.507.4.1.1. Noise exposure where noise contours are not readily available. Buildings exposed to a noise level of 65 dB Leq - 1-hr during any hour of operation shall have building, addition or alteration exterior wall and roof-ceiling assemblies exposed to the noise source meeting a composite STC rating of at least 45 (or OITC 35), with exterior windows of a minimum STC of 40 (or OITC 30). 5.507.4.2 Performance Method. For buildings located as defined in Section 5.507.4.1 or 5.507.4.1.1, wall and roof-ceiling assemblies exposed to the noise source making up the building or addition envelope or altered envelope shall be constructed to provide an interior noise environment attributable to exterior sources that does not exceed an hourly equivalent noise level (Leq-1Hr) of 50 dBA in occupied areas during any hour of operation. 5.507.4.2.1 Site Features. Exterior features such as sound walls or earth berms may be utilized as appropriate to the building, addition or alteration project to mitigate sound migration to the interior. 5.507.4.2.2 Documentation of Compliance. An acoustical analysis documenting complying interior sound levels shall be prepared by personnel approved by the architect or engineer of record. 5.507.4.3 Interior sound transmission. Wall and floor-ceiling assemblies separating tenant spaces and tenant spaces and public places shall have an STC of at least 40. Note: Examples of assemblies and their various STC ratings may be found at the California Office of Noise Control: www.toolbase.org/PDF/CaseStudies/stc_icc_ratings.pdf. SECTION 5.508 OUTDOOR AIR QUALITY 5.508.1 Ozone depletion and greenhouse gas reductions. Installations of HVAC, refrigeration and fire suppression equipment shall comply with Sections 5.508.1.1 and 5.508.1.2. 5.508.1.1 Chlorofluorocarbons (CFCs). Install HVAC, refrigeration and fire suppression equipment that do not contain CFCs. 5.508.1.2 Halons. Install HVAC, refrigeration and fire suppression equipment that do not contain Halons. 5.504.4.6 Resilient flooring systems. Where resilient flooring is installed, at least 80 percent of floor area receiving resilient flooring shall meet the requirements of the California Department of Public Health,"Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specifications 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx#material 5.504.4.6.1 Verification of compliance. Documentation shall be provided verifying that resilient flooring materials meet the pollutant emission limits. 5.504.4.7 Thermal insulation Comply with the requirements of the California Department of Public Health, "Standard Method of the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, "Version 1.2, January 1.2, January 2017 (Emission testing method for California Specification 01350). See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx#material 5.504.4.7.1 Verification of compliance. Documentation shall be provided verifying that thermal insulation materials meet the pollutant emission limits. 5.504.4.8 Acoustical ceiling and wall panels. Comply with the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, " Version 1.2, January 2017 (Emission testing method for California Specification 01350). See California Department of Public Health's website for certification programs and testing labs. 5.504.4.8.1 Verification of compliance. Documentation shall be provided verifying that acoustical finish materials meet the pollutant emission limits. 5.504.5.3 Filters. In mechanically ventilated buildings, provide regularly occupied areas of the building with air filtration media for outside and return air that provides at least a Minimum Efficiency Reporting Value (MERV) of 13. MERV 13 filters shall be installed prior to occupancy, and recommendations for maintenance with filters of the same value shall be included in the operation and maintenance manual. Exceptions: Existing mechanical equipment. 5.504.5.3.1 Labeling. Installed filters shall be clearly labeled by the manufacturer indicating the MERV rating. 5.504.7 ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL. Where outdoor areas are provided for smoking, prohibit smoking within 25 feet of building entries, outdoor air intakes and operable windows and within the building as already prohibited by other laws or regulations; or as enforced by ordinances, regulations or policies of any city, county, city and county, California Community College, campus of the California State University, or campus of the University of California, whichever are more stringent. When ordinances, regulations or policies are not in place, post signage to inform building occupants of the prohibitions. 5.504.4.3.2 Verification. Verification of compliance with this section shall be provided at the request of the enforcing agency. Documentation may include, but is not limited to, the following: 1. Manufacturer's product specification 2. Field verification of on-site product containers 5.504.4.4 Carpet Systems. All carpet installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." Version 1.2, January 2017 (Emission testing method for California Specifications 01350). See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx#material 5.504.4.3 Paints and coatings. Architectural paints and coatings shall comply with VOC limits in Table 1 of the ARB Architectural Coatings Suggested Control Measure, as shown in Table 5.504.4.3, unless more stringent local limits apply. The VOC content limit for coatings that do not meet the definitions for the specialty coatings categories listed in Table 5.504.4.3 shall be determined by classifying the coating as a Flat, Nonflat or Nonflat-High Gloss coating, based on its gloss, as defined in Subsections 4.21, 4.36 and 4.37 of the 2007 California Air Resources Board Suggested Control Measure, and the corresponding Flat, Nonflat or Nonflat-High Gloss VOC limit in Table 5.504.4.3 shall apply. 5.504.4.3.1 Aerosol Paints and coatings. Aerosol paints and coatings shall meet the PWMIR Limits for ROC in Section 94522(a)(3) and other requirements, including prohibitions on use of certain toxic compounds and ozone depleting substances, in Sections 94522(c)(2) and (d)(2) of California Code of Regulations, Title 17, commencing with Section 94520; and in areas under the jurisdiction of the Bay Area Air Quality Management District additionally comply with the percent VOC by weight of product limits of Regulation 8 Rule 49. TABLE 5.504.4.1 - ADHESIVE VOC LIMIT1,2 Less Water and Less Exempt Compounds in Grams per Liter ARCHITECTURAL APPLICATIONS CURRENT VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT & ASPHALT TILE ADHESIVES 50 DRYWALL & PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVES 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT SPECIFICALLY LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP & TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD)50 WOOD 30 FIBERGLASS 80 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168, www.arb.ca.gov/DRDB/SC/CURHTML/R1168.PDF TABLE 5.504.4.2 - SEALANT VOC LIMIT Less Water and Less Exempt Compounds in Grams per Liter SEALANTS CURRENT VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NONPOROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 NOTE: FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THESE TABLES, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. 5.504.4 FINISH MATERIAL POLLUTANT CONTROL. Finish materials shall comply with Sections 5.504.4.1 through 5.504.4.6. 5.504.4.1 Adhesives, sealants and caulks. Adhesives, sealants, and caulks used on the project shall meet the requirements of the following standards: 1. Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant primers and caulks shall comply with local or regional air pollution control or air quality management district rules where applicable, or SCAQMD Rule 1168 VOC limits, as shown in Tables 5.504.4.1 and 5.504.4.2. Such products also shall comply with the Rule 1168 prohibition on the use of certain toxic compounds (chloroform, ethylene dichloride, methylene chloride, perchloroethylene and trichloroethylene), except for aerosol products as specified in subsection 2, below. 2. Aerosol adhesives, and smaller unit sizes of adhesives, and sealant or caulking compounds (in units of product, less packaging, which do not weigh more than one pound and do not consist of more than 16 fluid ounces) shall comply with statewide VOC standards and other requirements, including prohibitions on use of certain toxic compounds, of California Code of Regulations, Title 17, commencing with Section 94507. TABLE 5.504.4.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS2,3 GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS COATING CATEGORY CURRENT VOC LIMIT FLAT COATINGS 50 NONFLAT COATINGS 100 NONFLAT HIGH GLOSS COATINGS 150 A0.5c CALIFORNIA GREEN BUILDING CODE NOTES REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 3009 S Daimler St 11/18/2024 LOADING ZONE LOADING ZONE NO PA R K I N G PA R K I N G NO PA R K I N G NO NO P A R K I N G NO P A R K I N G NO P A R K I N G NO P A R K I N G PA R K I N G NO NO PARKING OVERALL SITE PLAN (FOR REFERENCE ONLY) PLAN SPECIFIC NOTES SITE LEGEND OVERALL SITE PLAN (FOR REFERENCE ONLY)SCALE: 1/16"=1'-0"01NORTH A1.1 REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 SCOPE OF WORK (FIRST FLOOR) EXISTING BUILDING 3009 S Daimler St 11/18/2024 LINE OF SIGHTS LINE OF SIGHTSCALE: 1:20001 A1.1a REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 LINE OF SIGHTSCALE: 1:20002 LINE OF SIGHTSCALE: 1:20003 3009 S Daimler St 11/18/2024 213T & 215T 213T & 215T 254T & 256T 254T & 256T FEC(E) FEC(E) FEC(E) FEC(E) FEC (E) FEC (E) 9 1 2 3 4 5 8 6 7 9.1 10 B C D EA OVERALL EXISTING FLOOR PLAN - FIRST FLOOR01SCALE: 3/32" = 1'-0"NORTH LEGEND REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 A2.0 OVERALL EXISTING FLOOR PLAN - FIRST FLOOR PLAN SPECIFIC NOTES 3009 S Daimler St 11/18/2024 213T & 215T 213T & 215T 254T & 256T 254T & 256T FEC(E) FEC(E) FEC(E) FEC(E) FEC (E) FEC (E) 9 1 2 3 4 5 8 6 7 9.1 10 B C D EA OVERALL FIRST FLOOR PLAN01SCALE: 3/32" = 1'-0"NORTH LEGEND REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 A2.1 OVERALL FLOOR PLAN - FIRST FLOOR PLAN SPECIFIC NOTES 3009 S Daimler St 11/18/2024 1 2 3 4 D E ENLARGED FLOOR & FINISH PLAN - FIRST FLOOR01SCALE: 1/4" = 1'-0"NORTH PLAN SPECIFIC NOTES WALL LEGEND REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 A2.1a ENLARGED FLOOR & FINISH PLAN - FIRST FLOOR PLAN LEGEND FINISH LEGEND 3009 S Daimler St 11/18/2024 B 1 2 B 1 2 ENLARGED DEMOLITION FLOOR PLAN - FIRST FLOOR01SCALE: 3/8" = 1'-0"NORTH PLAN SPECIFIC NOTES WALL LEGEND REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 A2.1b ENLARGED FLOOR PLANS - FIRST FLOOR ENLARGED RENOVATION FLOOR PLAN - FIRST FLOOR02SCALE: 3/8" = 1'-0"NORTH 3009 S Daimler St 11/18/2024 D E 1 2 3 4 ENLARGED FURNITURE & EQUIPMENT PLAN - FIRST FLOOR01SCALE: 1/4" = 1'-0"NORTH PLAN SPECIFIC NOTES LEGEND REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 A3.1a ENLARGED FURNITURE & EQUIPMENT PLAN - FIRST FLOOR 3009 S Daimler St 11/18/2024 C D E 1 2 3 4 A5.1a ENLARGED REFLECTED CEILING PLAN - FIRST FLOOR ENLARGED REFLECTED CEILING PLAN - FIRST FLOOR PLAN01SCALE: 1/4" = 1'-0"NORTH PLAN SPECIFIC NOTES CEILING LEGEND REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 3009 S Daimler St 11/18/2024 9 1 2 3 4 5 8 6 7 B C D EA 9.1 10 A6.1 OVERALL ROOF PLAN OVERALL ROOF PLAN01SCALE: 3/32" = 1'-0"NORTH LEGEND REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 3009 S Daimler St 11/18/2024 3009 S Daimler St 11/18/2024 234 2 3 A7.1 INTERIOR ELEVATIONS PLAN SPECIFIC NOTES INTERIOR ELEVATIONSCALE: 1/4"=1'-0"02 REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 INTERIOR ELEVATIONSCALE: 1/4"=1'-0"01 3009 S Daimler St 11/18/2024 10 9 5 12 2 3 A8.2 PLAN DETAILS 4 LIMITING WALL HEIGHT TABLE-L/240 600 S 162 54 (S) STUD MEMBER SPACING (IN.) O.C. 5 PSF L/240 (S) STUD MEMBER SPACING (IN.) O.C. 5 PSF L/240 - (S) STUD MEMBER SPACING (IN.) O.C. 5 PSF L/240 (S) STUD MEMBER SPACING (IN.) O.C. 5 PSF L/240 (S) STUD MEMBER SPACING (IN.) O.C. 5 PSF L/240 (S) STUD MEMBER SPACING (IN.) O.C. 5 PSF L/240600 MEMBER DEPTH:FLANGE WIDTH: 162 STYLE: S 54 MATERIAL THICKNESS: INTERIOR NON-STRUCTURAL COMPOSITE: US F T WALL BASE DOOR HEAD (JAMB SIM.) 14 WALL TO 6" ABOVE CEILING EXTERIOR WALL FURRING FULL HEIGHT NON-RATED WALL 813 7 6 REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 "A""B" · WALL TYPE SCHEDULE "C" WINDOW HEAD (JAMB & SILL SIM) WALL BRACE AT PURLIN WALL CONTROL JOINT CONTROL JOINT AT DOOR FRAME FIRE EXTINGUISHER CABINET FLOOR FINISH @ FLOOR SINK 15 19 18RESILIENT FLOORING TO CONC. RESILIENT TO RESILIENT FLOORING 3009 S Daimler St 11/18/2024 COMPRESSION STRUT LIGHT FIXTURE @SUSP'D CLNG. ATTACHED CLOSURE ANGLE 5 6 7 8 A8.5 CEILING & ROOF DETAILS 12 15 17 24 10 14 REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 UNATTACHED CLOSURE ANGLE CEILING HEADER TRANSITION PLATFORM FLASHINGROUND PIPE PENETRATION SQUARE PIPE PENETRATIONROOF SCREEN SECTION · · ROOF SCREEN SECTION @ PARAPET · · 3009 S Daimler St 11/18/2024 DOOR & WINDOW SCHEDULE FRAMEDOOR GA S K E T . EL E C T . REMARKSHARDWARE GROUP DOOR TYPES T WINDOW TYPE DOOR NOTES A9.0 DOOR & WINDOW SCHEDULE A B C REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 T DOOR HARDWARE T T T T T T D 3009 S Daimler St 11/18/2024 GENERAL REQUIREMENTS 1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS, PROJECT BOUNDARIES AND EXISTING CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF WORK. THE CONTRACTOR SHALL CROSS-CHECK DETAILS AND DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS WITH RELATED REQUIREMENTS ON OTHER CONSTRUCTION DOCUMENTS. 2. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE STRUCTURAL ENGINEER OF RECORD (SEOR) OF ANY CONFLICTS BETWEEN THE STRUCTURAL DRAWINGS AND OTHER CONSTRUCTION DOCUMENTS OR EXISTING CONDITIONS. THE CONTRACTOR SHALL NOT ORDER MATERIAL, FABRICATE ELEMENTS, OR CONSTRUCT ANY PORTION OF STRUCTURE THAT IS IN CONFLICT UNTIL RESOLUTION IS MADE. 3. WHEN DIMENSIONS ARE UNCLEAR, REQUEST CLARIFICATION FROM THE SEOR AND ARCHITECT. DO NOT SCALE DRAWINGS. UNLESS NOTED OTHERWISE, PLAN DIMENSIONS INDICATE CENTERLINE OF BEAMS AND COLUMNS, LIGHT- FRAMED WALLS ARE DIMENSIONED TO FACE OF STUDS, AND FOOTINGS ARE CENTERED UNDER THE ELEMENTS THEY SUPPORT. 4. WHERE INFORMATION IS CONFLICTING WITHIN THE STRUCTURAL DOCUMENTS, SPECIFIC DETAILS SHALL GOVERN OVER TYPICAL DETAILS, WHICH HAVE PRECEDENCE OVER THESE NOTES, WHICH IN TURN OVERRULE PROJECT SPECIFICATIONS. 5. DETAILS NOTED AS TYPICAL ON STRUCTURAL SHEETS SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY SHOWN OR NOTED OTHERWISE. WHERE NO DETAIL IS INDICATED, CONSTRUCTION SHALL BE OF THE SAME NATURE AS FOR SIMILAR CASES OF CONSTRUCTION ON THIS PROJECT. 6. THE ARCHITECT AND SEOR SHALL INTERPRET THE CONSTRUCTION DOCUMENTS IN CASE OF POSSIBLE CONFLICT OR DISCREPANCY BETWEEN STRUCTURAL AND OTHER DISCIPLINES. 7. THE CONTRACTOR SHALL PROVIDE ALL NEW (N) MATERIALS TO PERFORM THE WORK INDICATED ON STRUCTURAL DOCUMENTS UNLESS NOTED AS EXISTING (E) OR SUPPLIED BY OTHERS. WRITTEN APPROVAL FROM THE SEOR SHALL BE OBTAINED PRIOR TO THE SUBSTITUTION OF ANY MATERIAL OR PRODUCT SPECIFIED ON THE STRUCTURAL DOCUMENTS. 8. STRUCTURAL CONSTRUCTION DOCUMENTS REPRESENT THE FINISHED STRUCTURE, UNLESS OTHERWISE SHOWN THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION OR NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE DESIGN OF TEMPORARY ERECTION AIDS, FORMWORK, SCAFFOLDING, SAFETY MEASURES, SHORING OF ANY PORTION OF WORK, AND PROTECTION OF ADJACENT PROPERTIES. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. VISITS TO THE SITE BY THE SEOR SHALL NOT INCLUDE OBSERVATION OR INSPECTION OF THE ABOVE ITEMS AND DO NOT IN ANY WAY RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITIES FOR THE ABOVE. 9. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH THE PERTINENT SECTIONS OF THE "CONSTRUCTION SAFETY ORDERS" ISSUED BY THE STATE OF CALIFORNIA, LATEST EDITION, AND ALL OSHA REQUIREMENTS AS THEY APPLY TO THIS PROJECT. THE SEOR AND THE OWNER DO NOT ACCEPT ANY RESPONSIBILITY FOR THE CONTRACTOR'S FAILURE TO COMPLY WITH THESE. 10. ALL STRUCTURAL FRAMING SHALL BE ERECTED PLUMB AND TRUE TO LINE. TEMPORARY BRACING SHALL BE INSTALLED AND LEFT IN PLACE UNTIL ADEQUATE STRUCTURE IS CONSTRUCTED FOR STABILITY. 11. CONSTRUCTION MATERIALS AND ERECTION LOADS SHALL BE DISTRIBUTED WHEN PLACED ON THE STRUCTURE SUCH THAT THEY DO NOT EXCEED DESIGN LIVE LOADS OR RESULT IN AN UNBALANCED CONDITION. MAXIMUM PERMANENT EQUIPMENT WEIGHTS, POSTED LOAD LIMITS OR OTHER RESTRICTIONS NOTED ON THE STRUCTURAL DRAWINGS SHALL NOT BE EXCEEDED WITHOUT PRIOR WRITTEN APPROVAL BY THE SEOR. UNLESS SPECIFICALLY STATED, THE STRUCTURE IS NOT DESIGNED TO SUPPORT TRAFFIC FROM CRANES OR OTHER HEAVY CONSTRUCTION VEHICLES. 12. FLOOR, ROOF AND WALL OPENINGS, SLEEVES, INSERTS, EMBEDS, CONDUITS AND OTHER DISCIPLINE REQUIREMENTS MUST BE COORDINATED BEFORE THE CONTRACTOR PROCEEDS WITH CONSTRUCTION. THE EXACT DEPTH, EXTENT, AND LOCATION OF ALL FLOOR OR ROOF DEPRESSIONS, SLOPES, CURBS, PADS, TRENCHES, DRAINS AND OTHER FEATURES SHALL BE COORDINATED WITH THE CONSTRUCTION DOCUMENTS. THE STRUCTURAL DRAWINGS DO NOT NECESSARILY INDICATE ALL OF THESE ITEMS. 13. CORE DRILLING OF CONCRETE OR MASONRY IS NOT PERMITTED WITHOUT PRIOR APPROVAL BY THE SEOR. CORES, WHERE APPROVED SHALL NOT CUT REINFORCEMENT. THE CONTRACTOR SHALL PRESENT ALL CORES TO THE INSPECTOR OF RECORD (IOR) FOR VERIFICATION. 14. STRUCTURAL DRAWINGS INDICATE THE APPROXIMATE LOCATION OF EQUIPMENT AND THEIR SECONDARY FRAMING SUPPORTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WORK BETWEEN SUBCONTRACTORS AND CRAFTS IN ORDER TO PROVIDE NECESSARY DIMENSIONS IN A TIMELY MANNER TO ALL PARTIES AND DETAILERS INVOLVED. 15. PROVIDE A SHIM SPACE AT HEADERS AND JAMBS TO ALLOW FOR SETTLEMENT AND MOVEMENT OF FRAMING. INSTALL WINDOWS, DOORS AND OTHER INSET ITEMS IN WALLS AFTER BUILDING LOADS ARE FULLY APPLIED. 16. EXPANSION AND SEPARATION JOINT DIMENSIONS SHOWN INDICATE THE CLEAR DISTANCE REQUIRED. COMPONENTS COVERING OR CROSSING SUCH JOINTS MUST ACCOMMODATE THE JOINT FULLY CLOSING OR OPENING TO TWICE THE DIMENSION SHOWN, AS WELL AS RELATIVE LATERAL MOVEMENT ALONG THE JOINT. ALL PIPES, DUCTS, CONDUIT, ETC., CROSSING SUCH JOINTS SHALL HAVE FLEXIBLE LINES WITH ADEQUATE RANGE OF MOTION. STRUCTURAL DESIGN CRITERIA__________________________________________________________ CODES:DESIGN IS BASED ON THE 2022 CALIFORNIA BUILDING CODE LIVE LOADS (REDUCIBLE, UNO): ROOF, UNIFORM..................................................................................................................20 PSF TYPICAL OFFICE, UNIFORM + PARTITION ALLOWANCE................50 PSF + 15 PSF = 65 PSF WIND LOADS: RISK CATEGORY...........................................................................................................................II EXPOSURE....................................................................................................................................B ULTIMATE DESIGN WIDE SPEED, Vult............................................................................95 MPH INTERNAL PRESSURE COEFFICIENT, G Cpi.......................................................................± 0.18 EARTHQUAKE LOADS: RISK CATEGORY..........................................................................................................................II SEISMIC IMPORTANCE FACTOR, Ie.........................................................................................1.0 SITE CLASSIFICATION................................................................................................D-DEFAULT SPECTRAL ACCEL PARAMETERS (USGS ‘08)........................................SS = 1.265, S1 = 0.454 DESIGN SPECTRAL ACCEL PARAMETERS.........................................SDS = 1.012, SD1 = 0.562 SEISMIC DESIGN CATEGORY.....................................................................................................D SEISMIC FORCE RESISTING SYSTEM(S): NON STRUCTURAL COMPONENTS STRUCTURAL SUBMITTALS 1. REVIEW OF SHOP DRAWINGS AND SUBMITTALS BY THE SEOR IS FOR GENERAL CONFORMANCE WITH THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. SEE THE STRUCTURAL SUBMITTAL SCHEDULE AND PROJECT SPECIFICATIONS FOR REQUIREMENTS. 2. SHOP DRAWINGS FOR ITEMS SPECIFIED ON THE STRUCTURAL DOCUMENTS SHALL BE SUBMITTED TO THE SEOR FOR REVIEW PRIOR TO FABRICATION. THE CONTRACTOR IS RESPONSIBLE FOR CHECKING DIMENSIONS, AND ALL ERRORS OF DETAILING, FABRICATION, AND FIT UP OF STRUCTURAL MEMBERS INCLUDING COORDINATION WITH OTHER TRADES. 3. SHOP DRAWINGS SUBMITTED TO THE SEOR SHALL CONSIST OF ELECTRONIC FILES AND/OR TWO HARDCOPY SETS. ALLOW 10 BUSINESS DAYS FOR REVIEW BY THE SEOR UPON RECEIPT UNLESS ADVANCE NOTICE IS PROVIDED AND A REDUCED TIMEFRAME AGREED UPON. THE SEOR WILL RETURN ONE SET OF REVIEWED ELECTRONIC FILES OR HARDCOPY. SCHEDULE ALLOWANCE FOR REVIEWS AND PROCESSING TIME BY THE ARCHITECT, OWNER OR OTHER DISCIPLINES MAY BE REQUIRED. 4. SHOP DRAWINGS AND SUBMITTALS DO NOT CONSTITUTE CHANGE ORDERS. ANY PROPOSED DEVIATION FROM THE STRUCTURAL DOCUMENTS MUST BE SUBMITTED IN WRITING AS A REQUEST FOR SUBSTITUTION FOR APPROVAL BY THE SEOR. 5. SUBSTITUTION REQUESTS FOR MATERIALS SPECIFIED ON THE STRUCTURAL DOCUMENTS MAY BE CONSIDERED WITH MATERIALS HAVING EQUIVALENT OR GREATER CAPACITY AND PERFORMANCE. CURRENT EVALUATION REPORTS AND PRODUCT INFORMATION SHALL BE PROVIDED TO THE SEOR DEMONSTRATING EQUIVALENT QUALITIES OF THE MATERIAL TO BE SUBSTITUTED. 6. EACH CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF A MAIN WIND- OR SEISMIC- LATERAL FORCE RESISTING SYSTEM (LFRS), DESIGNATED SEISMIC SYSTEM, OR A WIND- OR SEISMIC-RESISTING COMPONENT LISTED IN THE STATEMENT OF SPECIAL INSPECTIONS SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. THE CONTRACTOR’S STATEMENT OF RESPONSIBILITY SHALL CONTAIN ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTION. THE STRUCTURAL SUBMITTAL SCHEDULE BELOW IS A SUMMARY LIST AND MAY NOT BE ALL INCLUSIVE OF SUBMITTALS REQUIRED FOR THIS PROJECT. PROVIDE ALL SUBMITTALS NOTED ON THE CONTRACT DOCUMENTS AND AS REQUIRED BY THE ARCHITECT, BUILDING OFFICIAL AND OWNER’S REPRESENTATIVE. STRUCTURAL SUBMITTAL SCHEDULE GENERAL REQ’D: QUALIFICATION DATA FOR APPROVED INSTALLERS AND FABRICATORS REQ’D: CERTIFICATES OF CONFORMANCE FOR PREFABRICATED MEMBERS REQ’D: STATEMENT OF RESPONSIBILITY FOR LFRS CONSTRUCTION CONCRETE FORMWORK NOT REQ’D: MANUFACTURER’S PRODUCT DATA AND INSTALLATION INSTRUCTIONS FOR PROPRIETARY MATERIALS INCLUDING FORM COATINGS, MANUFACTURED FORM SYSTEMS, TIES AND ACCESSORIES NOT REQ’D: SHOP DRAWINGS FOR FABRICATION AND ERECTION OF FORMWORK AND SHORING CONCRETE REINFORCEMENT REQ’D: MANUFACTURER’S PRODUCT DATA, SPECIFICATIONS AND INSTALLATION PROCEDURES FOR PROPRIETARY MATERIALS AND REINFORCEMENT REQ’D: STEEL PRODUCER’S CERTIFICATES OF MILL ANALYSIS, TENSILE AND BEND TESTS REQ’D: SHOP DRAWINGS FOR FABRICATION, BENDING AND PLACEMENT CAST-IN-PLACE CONCRETE REQ’D: DESIGN MIX FOR EACH CONCRETE MIXTURE, INDICATING LOCATION OF USE REQ’D: MATERIAL CERTIFICATES FOR CEMENT, AGGREGATES AND ADMIXTURES REQ’D: TEST CERTIFICATES FOR NON-POTABLE MIX WATER REQ’D: SHOP DRAWINGS FOR PROPOSED LOCATIONS OF CONSTRUCTION AND CONTROL JOINTS REQ’D: MINUTES FROM PREINSTALLATION CONFERENCE NOT REQ’D: MANUFACTURER’S PRODUCT DATA FOR WATERSTOPS, BONDING AGENTS, VAPOR RETARDERS, JOINT FILLER, CURING MATERIALS AND FLOOR TREATMENTS REQ’D: CERTIFICATION OF INSTALLERS FOR OVERHEAD ADHESIVE ANCHORS REQ’D: SHOP DRAWINGS FOR SHOTCRETE TEST PANELS AND MOCKUPS REQ’D: SHOTCRETE CONTRACTOR AND NOZZLEMENT QUALIFICATIONS MASONRY NOT REQ’D: DESIGN MIX FOR GROUT NOT REQ’D: MATERIAL TEST REPORTS STRUCTURAL STEEL REQ’D: MANUFACTURER’S MILL CERTIFICATES REQ’D: MILL TEST REPORTS REQ’D: SHOP DRAWINGS FOR FABRICATION AND ASSEMBLY OF MEMBERS REQ’D: ERECTION PLAN SEQUENCE AND PROCEDURES REQ’D: TEST REPORTS FOR SHOP AND FIELD WELDED AND BOLTED CONNECTIONS STEEL JOISTS REQ’D: SHOP DRAWINGS INDICATING LAYOUT AND DETAILS NOT REQ’D: MANUFACTURER’S MILL CERTIFICATES NOT REQ’D: ENGINEERING CALCULATIONS STEEL DECK REQ’D: SHOP DRAWINGS INDICATING TYPE, LAYOUT, DETAILS AND OPENINGS LARGER THAN 1 FOOT COLD-FORMED METAL FRAMING NOT REQ’D: SHOP DRAWINGS INDICATING LAYOUT AND DETAILS NOT REQ’D: ENGINEERING CALCULATIONS WELDING REQ’D: WELDING PROCEDURE SPECIFICATIONS (WPS) REQ’D: CERTIFICATES FOR ALL WELDERS VERIFYING CURRENT AWS QUALIFICATIONS ROUGH CARPENTRY NOT REQ’D: PRODUCT DATA FOR TREATMENTS AND PRESERVATIVES NOT REQ’D: MATERIAL CERTIFICATES FOR DIMENSION LUMBER PREFABRICATED WOOD PRODUCTS NOT REQ’D: SHOP DRAWINGS INDICATING LAYOUT AND DETAILS NOT REQ’D: ENGINEERING CALCULATIONS GLUE-LAMINATED BEAMS NOT REQ’D: SHOP DRAWINGS INDICATING LAYOUT NOT REQ’D: CERTIFICATE OF CONFORMANCE M/E/P COORDINATION REQ’D: SHOP DRAWINGS OF PROPOSED LAYOUT OF PIPES, DUCTS AND CONDUIT INDICATING DETAILS OF PENETRATIONS THROUGH STRUCTURE; GRAVITY AND SEISMIC FORCES OF SUPPORTS AND BRACING ON STRUCTURE DEFERRED APPROVALS REQ’D: DRAWINGS, AND AS APPLICABLE, STRUCTURAL DESIGN CALCULATIONS FOUNDATIONS REQ’D: INSTALLATION PLAN FOR PILES / MICROPILES REQ’D: AS BUILT RECORD SURVEY FOR PILES / MICROPILES SPECIAL INSPECTIONS SCHEDULE SOILS SUPPORTING FOUNDATIONS PERIODIC: VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL PERIODIC: VERIFY MATERIALS BELOW FOOTING ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. PERIODIC: PRIOR TO PLACEMENT OF CONTROLLED FILL, INSPECT SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY CONTINUOUS: VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF CONTROLLED FILLS PERIODIC: PERFORM CLASSIFICATION AND TESTING OF CONTROLLED FILL MATERIALS STRUCTURAL CONCRETE AND REINFORCEMENT PERIODIC: INSPECTIONS OF REINFORCING STEEL AND PLACEMENT PERIODIC: INSPECT BOLTS TO BE INSTALLED IN CONCRETE PRIOR TO AND DURING PLACEMENT OF CONCRETE PERIODIC: INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED PERIODIC: VERIFY USE OF REQUIRED DESIGN MIX PERIODIC: VERIFY COMPLIANCE OF NON-POTABLE MIX WATER CONTINUOUS: INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES CONTINUOUS: SAMPLING FRESH CONCRETE AND PERFORMING SLUMP AND AIR CONTENT TESTS & DETERMINING THE TEMPERATURE OF FRESH CONCRETE AT THE TIME OF MAKING SPECIMENS FOR STRENGTH TESTS PERIODIC: INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUE PERIODIC: VERIFICATION OF IN-SITU CONCRETE STRENGTH, PRIOR TO REMOVAL OF SHORES AND FORMS FROM BEAMS AND STRUCTURAL SLABS PERIODIC: ERECTION OF PRECAST CONCRETE MEMBERS PERIODIC: POST-INSTALLED AND ADHESIVE ANCHORS PERIODIC: VERIFY INSTALLER CERTIFICATIONS FOR OVERHEAD ADHESIVE ANCHORS CONTINUOUS: REBAR COUPLERS AND TERMINATORS, SELECT SPLICE SPECIMENS FOR TESTING CONTINUOUS: [DSA/OSHPD] POST-INSTALLED AND ADHESIVE ANCHORS STRUCTURAL STEEL PERIODIC: STRUCTURAL STEEL IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS PERIODIC: STRUCTURAL STEEL MANUFACTURER’S CERTIFIED MILL TEST REPORTS REQUIRED PERIODIC: INSPECTION OF STEEL FRAME BRACING & STIFFENER DETAILS FOR COMPLIANCE WITH APPROVED CONSTRUCTION DOCUMENTS PERIODIC: STEEL FRAME MEMBER LOCATIONS PERIODIC: APPLICATION OF JOINT DETAILS AT EACH CONNECTION PERIODIC: HIGH-STRENGTH BOLTS, NUTS, AND WASHERS IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS, MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED PERIODIC: INSPECTION OF HIGH-STRENGTH BOLTING BEARING-TYPE CONNECTIONS PERIODIC: INSPECTION OF SLIP-CRITICAL CONNECTIONS USING TURN-OF-NUT METHOD WITH MATCHMARKING, DIRECT TENSION INDICATOR METHOD, OR TWIST OFF BOLTS CONTINUOUS: INSPECTION OF SLIP-CRITICAL CONNECTIONS USING CALIBRATED WRENCH METHOD OR TURN-OF-NUT WITHOUT MATCHMARKING WELDING CONTINUOUS: COMPLETE AND PARTIAL PENETRATION GROOVE WELDS CONTINUOUS: FILLET WELDS > 5/16" AND MULTIPASS FILLET WELDS PERIODIC: FILLET WELDS ≤ 5/16" PERIODIC: METAL DECK WELDS PERIODIC: LIGHT GAUGE METAL WELDS PERIODIC: WELD FILLER MATERIAL IDENTIFICATION MARKINGS TO CONFORM TO AWS STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS, MANUFACTURE’S CERTIFICATION OF COMPLIANCE REQUIRED CONTINUOUS: WELDING OF REINFORCEMENT STEEL RESISTING SEISMIC FORCES, INDICATED ON PLANS AND DETAILS AS LFRS ELEMENT OR CONNECTIONS PERIODIC: VERIFICATION OF WELDABILITY OF REINFORCING STEEL OTHER THAN ASTM A706 CONTINUOUS: WELDING OF STIRRUPS, HOOPS OR TIES CONTINUOUS: REINFORCING WELDS IN CMU PERIODIC: ALL OTHER REINFORCEMENT WELDS, UNO ROUGH CARPENTRY / WOOD PERIODIC: FRAMING NAILS SIZE, TYPE AND FINISH PERIODIC: NAILING OF ROOF, WALL, & FLOOR SHEATHING PERIODIC: NAILING/BOLTING OF STRAPS, HOLDOWNS, BRACES AND DRAG STRUTS PERIODIC: MANUFACTURE OF STRUCTURAL GLUED-LAMINATED TIMBERS LARGER THAN 5-1/8" WIDE, 18" DEEP, OR CLEAR SPAN 32 FEET OR MORE PERIODIC: MANUFACTURE OF OPEN WEB TRUSSES PERIODIC: INSTALLATION OF TIMBER CONNECTORS PERIODIC: HIGH LOAD WOOD DIAPHRAGMS, VERIFY PANEL GRADE. THICKNESS, NOMINAL FRAMING SIZES AND FASTENERS PER APPROVED PLANS CONCRETE MASONRY PERIODIC: PROPORTIONS OF SITE- PREPARED MORTAR AND GROUT CONTINUOUS: PREPARATION OF GROUT & MORTAR SPECIMENS AND/OR PRISMS PERIODIC: VERIFICATION OF SIZE & LOCATION OF MASONRY UNITS PERIODIC: VERIFICATION OF SIZE, GRADE, TYPE AND PLACEMENT OF REINFORCING STEEL PERIODIC: VERIFICATION OF SIZE AND LOCATION OF ANCHORS OR EMBEDDED STRUCTURAL ELEMENTS INCLUDING OTHER DETAILS OF ANCHORAGE OF MASONRY TO STRUCTURAL MEMBERS, FRAMES OR OTHER CONSTRUCTION PERIODIC: CONSTRUCTION OF MORTAR JOINTS PERIODIC: GROUT SPACE CLEAN PRIOR TO GROUTING CONTINUOUS: GROUT PLACEMENT PER CONSTRUCTION DOCUMENTS & CODE COMPLIANCE PERIODIC: COMPLIANCE WITH REQUIRED INSPECTION PROVISIONS OF CONSTRUCTION DOCUMENTS & APPROVED SUBMITTALS SHALL BE VERIFIED PERIODIC: PROTECTION OF MASONRY DURING COLD WEATHER BELOW 40˚F OR HOT WEATHER ABOVE 90˚F PERIODIC: POST-INSTALLED ANCHORS AND REINFORCEMENT CONTINUOUS: [DSA / OSHPD] POST-INSTALLED ANCHORS AND REINFORCEMENT COLD-FORMED STEEL FRAMING PERIODIC: SCREW ATTACHMENT, BOLTING, AND ANCHORING OF STRAPS, HOLDOWNS, BRACES, DRAG STRUTS, AND ROOF, WALLS AND FLOORS. PERIODIC: INSTALLATION OF STEEL DECKING PER SDI QA/QC STANDARDS STATEMENT OF SPECIAL INSPECTIONS 1. THE OWNER SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PROVIDE INSPECTIONS DURING CONSTRUCTION. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO DEMONSTRATES COMPETENCE TO THE SATISFACTION OF THE BUILDING OFFICIAL FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. 2. SEE THE SPECIAL INSPECTIONS SCHEDULE AND PROJECT SPECIFICATIONS FOR REQUIREMENTS. IT IS SOLELY THE CONTRACTOR’S RESPONSIBILITY TO SEE THAT THESE INSPECTIONS ARE PERFORMED. 3. SPECIAL INSPECTIONS ARE NOT REQUIRED WHERE THE WORK IS DONE ON THE PREMISES OF A FABRICATOR REGISTERED AND APPROVED TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION. APPROVED FABRICATORS MUST SUBMIT A CERTIFICATE OF COMPLIANCE FOR OFFSITE FABRICATIONS SUCH AS STRUCTURAL STEEL, PRECAST CONCRETE, GLUED LAMINATED TIMBER, ETC. 4. ALL INSPECTIONS SHALL BE PERFORMED BY INDEPENDENT SPECIAL INSPECTORS. JOB SITE VISITS BY THE STRUCTURAL ENGINEER OR BUILDING OFFICIAL DO NOT CONSTITUTE AND ARE NOT A SUBSTITUTE FOR INSPECTIONS BY A SPECIAL INSPECTOR. 5. ALL INSPECTION REPORTS SHALL BE SUBMITTED TO THE BUILDING OFFICIAL AND SEOR. THE FINAL REPORTS BY THE SPECIAL INSPECTOR(S) MUST CERTIFY THAT THE ENTIRE STRUCTURAL SYSTEM COMPLIES WITH THE APPROVED PLANS AND SPECIFICATIONS. 6. WORK REQUIRING SPECIAL INSPECTION SHALL BE INSPECTED BY THE SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK IS PERFORMED AND AT THE COMPLETION OF WORK. CONTINUOUS INSPECTION CONSISTS OF FULL-TIME INSPECTION; PERIODIC INSPECTION CONSISTS OF PART-TIME OR INTERMITTENT INSPECTION. 7. THE SPECIAL INSPECTIONS SCHEDULE BELOW IS A SUMMARY LIST AND MAY NOT BE ALL INCLUSIVE OF INSPECTIONS REQUIRED FOR THIS PROJECT. THE CONTRACTOR SHALL CALL FOR ALL INSPECTIONS NOTED ON THE CONTRACT DOCUMENTS AND AS REQUIRED BY THE ARCHITECT, BUILDING OFFICIAL AND OWNER’S REPRESENTATIVE. No. 6250 FFOHSIB RYAN W. REGISTEREDPROFESSIONALENGINEER STRUCTURALSTATEOFCALIFORNIA DATE: FOR BRANDOW & JOHNSTON STRUCTURAL+CIVIL ENGINEERS (B&J HBK, INC.) 3300 IRVINE AVE. SUITE 245 NEWPORT BEACH, CALIFORNIA 92660 T:(949)862-8500 WWW.BJSCE.COM JOB#: 1 7 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 a r c h i t e c t u r e i n t e r i o r d e s i g n p l a n n i n g DA I M L E R A C P L 30 0 9 D A I M L E R S T SA N T A A N A , C A 9 2 7 9 5 S0.1 GENERAL NOTES 07/23/24 NO. REMARKS DATE 60% COMPLETE SET 05/28/24 90% COMPLETE SET 07/12/24 ISSUE FOR BID 07/16/24 CITY SUBMITTAL 07/23/24 NON-STRUCTURAL COMPONENTS PERIODIC: ERECTION AND FASTENING OF EXTERIOR CLADDING, INTERIOR AND EXTERIOR NONBEARING WALLS, AND INTERIOR AND EXTERIOR VENEER GREATER 30' HEIGHTS, EXTERIOR WALLS GREATER THAN 5 PSF, AND INTERIOR WALLS MORE THAN 15 PSF PERIODIC: ANCHORAGE OF ELECTRICAL EQUIPMENT PERIODIC: ANCHORAGE OF SUSPENDED CEILING SYSTEMS PERIODIC: ANCHORAGE OF HVAC DUCTWORK THAT WILL CONTAIN HAZARDOUS MATERIALS PERIODIC: ANCHORAGE OF PIPING SYSTEMS AND MECHANICAL UNITS CONTAINING FLAMMABLE, COMBUSTIBLE OR HIGHLY TOXIC MATERIALS PERIODIC: ANCHORAGE OF ACCESS FLOORS AND ANCHORAGE OF STORAGE RACKS 8 FEET OR GREATER IN HEIGHT PERIODIC: FLEXIBLE CONNECTIONS OF UTILITIES CROSSING EXPANSION OR SEISMIC JOINTS PRESTRESSED CONCRETE PERIODIC: INSPECTION OF PRESTRESSNG TENDON PLACEMENT AND SIZES PERIODIC: VERIFICATION OF IN-SITU CONCRETE STRENGTH PRIOR TO STRESSING OF TENDONS IN POST-TENSIONED CONCRETE CONTINUOUS: APPLICATION OF PRESTRESSING LOADS CONTINUOUS: GROUTING OF BONDED PRESTRESSING TENDONS IN THE LFRS PIER FOUNDATIONS CONTINUOUS: OBSERVE DRILLING OPERATIONS AND MAINTAIN COMPLETE AND ACCURATE RECORDS FOR EACH PIER CONTINUOUS: VERIFY PLACEMENTS, LOCATIONS AND PLUMBNESS, CONFIRM PIER DIAMETERS, BELL DIAMETERS, LENGTHS, EMBEDMENT INTO BEDROCK (IF APPLICABLE) AND ADEQUATE END BEARING STRATA CAPACITY PILE FOUNDATIONS CONTINUOUS: VERIFY PILE MATERIALS, SIZES AND LENGTHS COMPLY WITH THE APPROVED CONSTRUCTION DOCUMENTS CONTINUOUS: DETERMINE CAPACITIES OF TEST PILES AND CONDUCT ADDITIONAL LOAD TESTS AS REQUIRED CONTINUOUS: OBSERVE DRIVING OPERATIONS AND MAINTAIN COMPLETE AND ACCURATE RECORDS FOR EACH PILE CONTINUOUS: VERIFY PLACEMENT, LOCATIONS AND PLUMBNESS, CONFIRM TYPE AND SIZE HAMMER, RECORD NUMBER OF BLOWS PER FOOT OF PENETRATION, DETERMINE REQUIRED PENETRATIONS TO ACHIEVE DESIGN CAPACITY, RECORD TIP AND BUTT ELEVATIONS AND DOCUMENT ANY PILE DAMAGE LE A V E B L A N K F O R C I T Y S T A M P 3009 S Daimler St 11/18/2024 PRODUCT SPECIFICATION 1. THE STRUCTURAL PRODUCT SCHEDULE INDICATES BASIS-OF-DESIGN MANUFACTURERS AND PRODUCTS FOR USE ON THIS PROJECT. WHERE STRUCTURAL PRODUCTS ARE NOT EXPLICITLY NAMED IN THE CONSTRUCTION DOCUMENTS, PROVIDE A LISTED PRODUCT. 2. PRODUCTS SHALL BE INSTALLED PER THE MANUFACTURER’S INSTALLATION INSTRUCTIONS AS AMENDED BY THE REFERENCED PRODUCT ACCEPTANCE REPORTS (ICC, IAPMO, ETC.) FOR THE INTENDED USE. 3. AT CONTRACTOR’S OPTION, SUBSTITUTION REQUESTS MAY BE MADE FOR LIKE PRODUCTS WHICH DEMONSTRATE QUALITIES THAT EQUAL OR EXCEED THOSE OF SPECIFIED PRODUCTS. EXISTING CONDITIONS 1. SEE ORIGINAL DRAWINGS FOR EXISTING BUILDING INFORMATION NOT SHOWN OR NOTED. 2. SEE PROJECT REPORTS AND ARCHITECTURAL DRAWINGS FOR HAZARDOUS MATERIALS (LEAD, ASBESTOS, ETC.) ABATEMENT REQUIREMENTS. 3. WHERE EXISTING CONDITIONS VARY SIGNIFICANTLY FROM THOSE SHOWN ON THESE DRAWINGS, THE SEOR SHALL BE NOTIFIED PRIOR TO CONTINUED CONSTRUCTION RELATED TO SUBJECT CONDITIONS. 4. EXISTING CONCRETE SURFACES TO BE IN CONTACT WITH NEW CONCRETE SHALL BE ROUGHENED AS FOR TYPICAL CONSTRUCTION JOINTS, AND AN ASTM C1059 COMPLIANT BONDING AGENT SHALL BE APPLIED PRIOR TO PLACING NEW CONCRETE. 5. DO NOT CUT OR DAMAGE EXISTING CONCRETE OR MASONRY REINFORCEMENT EXCEPT AS CLEARLY INDICATED. MAINTAIN AT LEAST 2 INCHES CLEAR TO EXISTING REINFORCEMENT, CONDUIT AND OTHER EMBEDDED ITEMS FROM CUTS, CORES, DRILL HOLES, SHOTPINS, ETC. IN AREAS OF WORK, MARK LOCATIONS OF SUCH ITEMS USING NONDESTRUCTIVE METHODS SUCH AS GROUND PENETRATING RADAR OR X-RAY. 6. THE GENERAL CONTRACTOR SHALL COORDINATE THE SPECIFIC LOCATION OF REPLACEMENT MECHANICAL EQUIPMENT WITH THE STRUCTURAL FRAMING. IF NEW EQUIPMENT DEVIATES IN WEIGHT, SIZE OR LOCATION FROM EXISTING EQUIPMENT BEING REPLACED, SEOR APPROVAL MUST BE OBTAINED PRIOR TO INSTALLATION OF THE UNITS. 7. EXISTING STRUCTURAL MEMBERS SUPPORTING NEW EQUIPMENT SHALL BE INSPECTED FOR DAMAGE AND DETERIORATION PRIOR TO INSTALLATION OF THE UNITS. NOTIFY THE SEOR OF SUCH CONDITIONS AND DO NOT INSTALL UNITS UNTIL THE CONDITIONS ARE ADDRESSED. 8. DURING THE COURSE OF WORK, NOTIFY THE SEOR OF EXISTING STRUCTURAL DETERIORATION, APPARENT DISTRESS, WATER INTRUSION, OR COMPROMISED MEMBERS THAT ARE DISCOVERED. 9. REPAIR FIREPROOFING, WATERPROOFING AND FINISHES AS REQUIRED WHERE DISTURBED BY STRUCTURAL WORK. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS. 10. EXISTING WOOD MEMBER SIZES MAY BE FULL-SIZE OR NONSTANDARD RELATIVE TO CURRENT PRACTICE. PROVIDE FULL-SIZE CURED, OR CUT NEW STRUCTURAL WOOD TO MATCH WHERE INDICATED. DO NOT FUR OUT TO MAKE UP GAPS BETWEEN NEW STRUCTURAL MEMBERS OR SHEATHING UNLESS SPECIFICALLY DETAILED OR NOTED. 2” 1 1/2" 3" 2” 1 1/2" MINIMUM CONCRETE COVER OF REINFORCEMENT SCHEDULE CONDITION INTERIOR RAISED SLABS AND INTERIOR WALL FACES INTERIOR COLUMNS AND BEAMS OTHER INTERIOR CONCRETE, #11 BARS AND SMALLER FORMED AND EXPOSED TO SOIL OR WEATHER, #6 BARS AND LARGER: #5 BARS AND SMALLER: CAST AGAINST AND PERMANENTLY EXPOSED TO SOIL STRUCTURAL SLAB-ON-GRADE, FROM BOTTOM OF SLAB: FROM TOP OF SLAB: SEE ESR 26049 25966 ADHEVISE ANCHOR TO GROUTED CMU 25620 26050 FIBER-REINFORCED POLYMER (FRP) SYSTEMS REINFORCEMENT BAR TERMINATOR 25342 25347 24507 REINFORCEMENT BAR COUPLER 02725 25860 WELDED STUD 25979 25560 SCREW ANCHOR TO GROUTED CMU (≥ 1/4” DIAM) 25577M 25864 25831 25936 EXPANSION ANCHOR TO GROUTED CMU 25675 22668 25469 SHOTPIN 25975 SCREW ANCHOR TO CONCRETE (≤ 3/16” DIAM) 25897 25741 25808 SCREW ANCHOR TO CONCRETE (≥ 1/4” DIAM) 25964 26028 - 26035 25960 NA ADHESIVE ANCHOR TO CONCRETE NA 25831 25891 STRUCTURAL PRODUCT SCHEDULE LARR EXPANSION ANCHOR TO CONCRETE 25815 25893 REINFORCING STEEL 1. PLACING TOLERANCES AND BAR SUPPORTS SHALL CONFORM TO THE “MANUAL OF STANDARD PRACTICE” FOR REINFORCED CONCRETE CONSTRUCTION, BY CONCRETE REINFORCING STEEL INSTITUTE (CRSI). 2. ALL REINFORCING BAR (REBAR) STEEL SHALL BE DEFORMED ROUND BARS CONFORMING TO ASTM A615 OR ASTM A706, GRADE 60. 3. WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A1064. ADJACENT WWF SHEETS SHALL BE LAPPED 12 INCHES MINIMUM. 4. PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT REINFORCING IN POSITIONS INDICATED. CHAIRS OR BOLSTERS WHICH BEAR AGAINST FORMS FOR EXPOSED SURFACES SHALL BE GREY COLORED PLASTIC COATED STEEL OR STAINLESS STEEL. 5. REINFORCING BARS SHALL BE KEPT CLEAN AND FREE OF OIL, GREASE AND LOOSE RUST OR MILL SCALE. 6. BEND REINFORCING BARS COLD. BARS PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT. 7. ALL REINFORCING SHALL BE CONTINUOUS UNLESS NOTED OTHERWISE, WITH CONTACT LAP SPLICES PER THE TYPICAL DETAILS OR AS SHOWN. 8. PROVISION FOR LAP SPLICES OR DOWELS SHALL BE PROVIDED ACROSS ALL CONSTRUCTION JOINTS AND SHALL BE THE SAME GRADE, SIZE AND SPACING AS REINFORCING CONTINUING BEYOND UNLESS NOTED OTHERWISE. IN LIEU OF SPLICES OR DOWELS, THE CONTRACTOR MAY SUBMIT FOR SEOR APPROVAL THE LOCATION AND MANUFACTURER DATA OF FORMSAVERS OR COUPLERS PRIOR TO THEIR USE. 9. ALL BENDS WITHIN HOOKS, STIRRUPS, HOOPS AND CROSS-TIES SHALL ENGAGE A LONGITUDINAL BAR, PROVIDE A #5 CONTINUOUS BAR WHERE ONE IS NOT SPECIFICALLY DETAILED. 10. CLEARANCE BETWEEN PARALLEL BARS, OR BARS AND CONSTRUCTION JOINTS SHALL BE NOT LESS THAN THE SMALLER OF 1 INCH, 1 BAR DIAMETER, OR THE MAXIMUM AGGREGATE SIZE. UNLESS NOTED OTHERWISE, BARS IN PARALLEL LAYERS SHALL BE PLACED IN ALIGNMENT WITH ONE ANOTHER. 11. MAINTAIN A MINIMUM COVER FROM FACE OF CONCRETE TO EDGE OF REINFORCEMENT PER THE MINIMUM CONCRETE COVER OF REINFORCEMENT SCHEDULE OR AS DETAILED. PROVIDE THE LARGEST COVER REQUIRED FOR ALL APPLICABLE CONDITIONS AND BAR SIZES. WHERE #3 STIRRUPS OR TIES ARE USED, ENSURE THAT THE COVER FOR LONGITUDINAL BARS IS ADEQUATE. 12. THE FOLLOWING REINFORCEMENT SHALL CONFORM TO ASTM A706: a. REINFORCEMENT TO BE WELDED. b. LONGITUDINAL COLUMN AND BEAM REINFORCEMENT IN DESIGNATED MOMENT FRAMES. c. VERTICAL REINFORCEMENT AT INTERSECTIONS AND ENDS OF DESIGNATED CONCRETE SHEAR WALLS ENCLOSED IN TIES. 3/4" CLRCLEARANCE FROM METAL DECK ESR-4143 ESR-3200 ER-0281 ESR-2103 ESR-2606 ESR-2495 ESR-2746 ER-0129 ESR-2856 ESR-2907 ESR-3056 ESR-1056 ESR-0677 ESR-2818 ESR-2502 ER-0240 ESR-2269 ESR-1799 ESR-2138 ESR-2202 ESR-3027 ESR-2713 ESR-2526 ESR-3187 ESR-3814 ESR-4027 ESR-3298 ER-0263 ESR-4057 ESR-4266 ESR-2502 ESR-3037 ESR-2746 ER-0188 HILTI HIT-HY 270 DEWALT/POWERS AC100+ GOLD SIMPSON AT-XP FYFE TYFO FIBRWRAP STRUCTURAL TECH V-WRAP DAYTON BAR LOCK L-SERIES HRC 500/510 XTENDER LENTON NELSON SHEAR CONNECTOR STUDS NELSON D2L DEFORMED BAR ANCHOR HILTI KWIK HUS-EZ SIMPSON TITEN HD HILTI KWIK BOLT 1 DEWALT/POWERS STUD+ SD1 DEWALT/POWERS STUD+ SD4, SD6 SIMPSON STRONG-BOLT 2 HILTI LOW-VELOCITY X-U ITW RAMSET POWER-DRIVEN SIMPSON POWDER-ACTUATED ITW RED HEAD TAPCON HILTI KWIK HUS-EZ, -EZ 1 SIMPSON TITEN HD DEWALT/POWERS WEDGE-BOLT+ HILTI HIT-HY 200 HILTI HIT-RE 500-V3 DEWALT/POWERS AC200+ DEWALT/POWERS PURE110+ SIMPSON AT-XP SIMPSON SET-3G HILTI KWIK BOLT TZ2 DEWALT/POWERS-STUD+ SD2 SIMPSON STRONG-BOLT 2 HRC 555/670 HEADED REINF. BARS LENTON TERMINATOR ICC / IAPMOPRODUCTTYPE MIN.COVER 1” 1 1/2" 3/4" STRUCTURAL CONCRETE 1. CONCRETE SHALL BE MIXED, PLACED AND CURED IN ACCORDANCE WITH ACI 318 AND ACI 301 LATEST EDITION AND THE CONSTRUCTION DOCUMENTS. 2. CONCRETE MIXING OPERATIONS SHALL CONFORM TO ASTM C94. QUANTITIES OF MATERIALS SHALL BE CERTIFIED BY A LICENSED WEIGHT-MASTER. 3. RETAIN AN APPROVED TESTING LABORATORY, ACCEPTABLE TO THE OWNER, TO PREPARE CONCRETE MIX DESIGNS ACCORDING TO GOVERNING CODE AND THE CONSTRUCTION DOCUMENTS. ALL CONCRETE MIXES SHALL BE STAMPED AND SEALED BY A LICENSED CALIFORNIA CIVIL ENGINEER AND SUBMITTED TO THE SEOR FOR REVIEW PRIOR TO CONCRETE PLACEMENT. NEW MIX DESIGNS ARE REQUIRED WHEN THERE IS A CHANGE IN MATERIALS BEING USED. MIX DESIGNS SHALL CLEARLY STATE THE INTENDED LOCATION FOR USE. 4. CONCRETE SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS AS INDICATED ON THE CONCRETE SCHEDULE. ALL CONCRETE TEST REPORTS SHALL BE SUBMITTED TO THE SEOR WITHIN 7 DAYS AFTER TESTING. 5. AGGREGATE SHALL BE HARDROCK FOR NORMAL WEIGHT CONCRETE (NWC) CONFORMING TO ASTM C33. THE UNIT WEIGHT OF NWC SHALL HAVE AN AIR-DRY EQUILIBRIUM DENSITY OF 145 ± 5 PCF. THE UNIT WEIGHT OF NWC SHALL BE CONFIRMED BY THE MIX DESIGN AND DOES NOT REQUIRE TESTING UNO. 6. AGGREGATE FOR SAND LIGHT WEIGHT CONCRETE (LWC) SHALL CONFORM TO ASTM C330. UNIT WEIGHT OF LWC SHALL NOT EXCEED 115 PCF MEASURED AIR-DRY EQUILIBRIUM DENSITY PER ASTM C567, OR 110 PCF MEASURED OVEN-DRY. THE UNIT WEIGHT OF LWC SHALL BE LAB TESTED FOR EACH MIX DESIGN AND AGGREGATE SOURCE. 7. COARSE AGGREGATE WITH A MAXIMUM SIZE OF 1/2 INCH OR LESS SHALL BE CRUSHED STONE. 8. PORTLAND CEMENT TYPE SHALL BE AS SPECIFIED IN THE CONCRETE SCHEDULE AND CONFORM TO ASTM C150, LOW ALKALI. 9. FLY ASH OR OTHER POZZOLANS CONFORMING TO ASTM C618 CLASS F MAY BE USED AS A PARTIAL SUBSTITUTION FOR PORTLAND CEMENT UP TO A MAXIMUM OF 25% TOTAL CEMENTITIOUS MATERIAL BY WEIGHT WHEN THE MIX DESIGN IS PROPORTIONED BY FIELD EXPERIENCE OR TRIAL MIXTURES. 10. WATER USED IN MIX SHALL BE POTABLE OR NONPOTABLE RECLAIMED/RECYCLED, CONFORMING TO ASTM C1602. PRIOR TO MIXING, FREE MOISTURE CONTENT OF AGGREGATES SHALL BE MEASURED, RECORDED, AND MIX WATER QUANTITY ADJUSTED ACCORDINGLY. MIX WATER AND FREE MOISTURE ON AGGREGATES SHALL NOT CONTAIN CHLORIDES OR ANY OTHER DELETERIOUS OR ODOROUS COMPOUNDS. 11. ADMIXTURES, WHERE USED FOR WATER REDUCTION AND SETTING TIME MODIFICATION SHALL CONFORM TO ASTM C494, SUPERPLASTICIZER SHALL CONFORM TO ASTM C1017. 12. SHRINKAGE REDUCING ADMIXTURES SHALL CONFORM TO ASTM C494, AND WHERE USED SHALL BE GRACO ECLIPSE, EUCLID EUCON SRA, SIKA CONTROL, OR APPROVED EQUAL. SPECIFIED MAXIMUM SHRINKAGE RATES SHALL BE LAB TESTED PER ASTM C157 FOR EACH MIX DESIGN AND AGGREGATE SOURCE. 13. WHERE SPECIFIED, AIR CONTENT SHALL BE SAMPLED AT THE POINT OF DISCHARGE AND FIELD TESTED PER ASTM C231, PRESSURE METHOD. 14. UNLESS OTHERWISE SPECIFIED, CONCRETE SHALL HAVE A MAXIMUM SLUMP OF 5 INCHES WITHOUT ADMIXTURES, AND A MAXIMUM OF 8 INCHES WHERE WATER REDUCTION OR SUPERPLASTICIZER ADMIXTURES ARE USED. SLUMP SHALL BE MEASURED PER ASTM C143 AT THE POINT OF DELIVERY WITH TOLERANCES PER ASTM C94. SELF CONSOLIDATING CONCRETE SHALL HAVE A MAXIMUM SPREAD OF 26 INCHES AS MEASURED PER ASTM C1611. 15. FOR LIGHT WEIGHT CONCRETE SLABS AND FILL OVER DECK, MAXIMUM AIR CONTENT SHALL BE 3 PERCENT AND MAXIMUM SLUMP SHALL BE 5 INCHES, MEASURED WITH ADMIXTURES. 16. USE PLACEMENT AND FINISHING PROCEDURES THAT PREVENT DELAMINATION, BLISTERING OR OTHER SURFACE DEFECTS. 17. NONSHRINK OR DRYPACK GROUT SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 5000 PSI, AND SHALL BE MASTERFLOW 713, EUCON NS GROUT, SIKA GROUT 212, OR APPROVED EQUAL. FOR THICK GROUT LAYERS AND LARGE VOLUME PLACEMENTS FOLLOW MANUFACTURER’S GUIDELINES, WHICH MAY INCLUDE THE ADDITION OF WASHED COARSE AGGREGATE AND POUR SEQUENCING. UNDER BASE PLATES LARGER THAN 6 SQUARE FEET, USE MASTERFLOW 928 OR OTHER APPROVED HI-FLOW GROUT. 18. THE USE OF CONSTRUCTION JOINTS (CJ) AT LOCATIONS NOT SHOWN ON THE PLANS AND DETAILS SHALL BE APPROVED BY THE SEOR PRIOR TO PLACEMENT OF CONCRETE. CJ’S SHALL BE USED WHENEVER CONCRETE PLACEMENT IS INTERRUPTED FOR MORE THAN 30 MINUTES. HORIZONTAL/FLAT CJ’S MAY BE UNFORMED, VERTICAL CJ’S SHALL BE FULLY FORMED WITH SHEAR KEYS. CJ’S SHALL BE CLEANED, LAITANCE REMOVED, AND ROUGHENED TO AN AMPLITUDE OF 1/4 INCH BY REMOVING THE ENTIRE SURFACE TO EXPOSE CLEAN AGGREGATE SOLIDLY EMBEDDED IN THE MORTAR MATRIX. IMMEDIATELY BEFORE NEW CONCRETE IS PLACED CJ’S SHALL BE WETTED AND STANDING WATER REMOVED. 19. PIPES, DUCTS OR CONDUIT SHALL NOT BE PLACED IN STRUCTURAL CONCRETE UNLESS SPECIFICALLY DETAILED ON THE STRUCTURAL DRAWINGS. PROVIDE SLEEVES FOR ALL PIPES THROUGH CONCRETE WALLS AND FOOTINGS. 20. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ALL MOULDS, REVEALS, GROOVES, CHAMFERS, DRIPS, ORNAMENTS AND OTHER FINISH REQUIREMENTS. UNLESS OTHERWISE NOTED, EXPOSED CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC. SHALL BE FORMED WITH 3/4 INCH CHAMFER STRIPS OR 1/2 INCH RADIUS TOOLED EDGE. 21. ALL DOWELS, ANCHORS AND OTHER EMBEDMENTS TO BE SET IN CONCRETE OR GROUT SHALL BE SECURED IN POSITION PRIOR TO PLACEMENT, NO WET SETTING, STABBING, RODDING OR OTHER MOVEMENT OF EMBEDDED ITEMS SHALL BE ALLOWED. THE CONTRACTOR SHALL COORDINATE WITH CONTRACT DOCUMENTS AND DISCIPLINES ITEMS SUCH AS; REINFORCEMENT, ANCHORS, INSERTS, HANGERS, NOSING, GUARDS, ELECTRICAL GROUNDS, INTEGRAL FRAMES, ETC. 22. CONCRETE AND GROUT MAINTAINED BETWEEN 50 TO 90 DEGREES FAHRENHEIT AND IN A MOIST, WIND SHELTERED CONDITION FOR A MINIMUM OF 7 DAYS AFTER PLACEMENT DOES NOT REQUIRE A WRITTEN PROTECTION PLAN. WHERE REQUIRED BY WEATHER AND SITE CONDITIONS, THE CONTRACTOR SHALL FOLLOW AN APPROVED COLD- OR HOT- WEATHER PROTECTION PLAN COMPLYING WITH ACI 306.1 / 301. 23. PRIOR TO ERECTING ANY ELEMENTS THAT LOAD THE FOUNDATION, CONCRETE MUST REACH AN UNCONFINED COMPRESSION STRENGTH OF 2000 PSI MINIMUM AS DETERMINED BY CYLINDER TESTING, AND MUST BE ALLOWED TO CURE FOR A MINIMUM OF 3 DAYS. 24. REVIEW MANUFACTURER REQUIREMENTS FOR OVERLAYMENTS, FINISHES AND FLOORING SYSTEMS TO BE APPLIED TO CONCRETE AS THESE MAY BE MORE RESTRICTIVE. 25. STYROFOAM VOID FILLER SHALL BE A DOW BUILDING SOLUTIONS PRODUCT “BLUE BOARD” TYPE OR APPROVED EQUAL WITH PROPERTIES APPROPRIATE FOR THE CONDITIONS OF USE. CONCRETE SCHEDULE NOTES: 1. PORTLAND CEMENT TYPE. 2. INDICATES NORMAL WEIGHT CONCRETE (NWC). OR SAND LIGHT WEIGHT CONCRETE (LWC). 3. MINIMUM 28-DAY CYLINDER COMPRESSIVE STRENGTH IN PSI. 4. MAXIMUM WATER TO CEMENTITIOUS MATERIAL RATIO, INCLUDING FREE MOISTURE ON AGGREGATES. * 0.45 MAXIMUM W/C RATIO REQUIRED FOR CONCRETE RECEIVING ADHESIVE FINISHES. 5. MAXIMUM AGGREGATE SIZE, SEE ACI 318 FOR ADDITIONAL REQUIREMENTS INCLUDING GRADATION. 6. MAXIMUM SHRINKAGE AT 28 DAYS. 0.05% 654321 STRUCTURAL CONCRETE SCHEDULE SHRINKAGE - 0.05% 0.05% NEW WALL IN-FILLS ALL OTHER CONCRETE AGG SIZEW/C RATIOSTRENGTHTYPECEMENT LOCATION 1 1/2”0.454500NWCIIFOUNDATIONS 1” 0.45 SLAB-ON-GRADE NWC II 4500 NEW WALLS 1" 0.454000NWCII 1"0.45 3000NWCII -1"0.553000NWCII 0.05%FILL OVER METAL DECK 1" 0.453000LWCII 0.05%RAISED SLABS & BEAMS 1" 0.454000NWCII POST INSTALLED ANCHORS 1. UNLESS OTHERWISE NOTED ON THE DRAWINGS, THE FOLLOWING APPLIES TO ALL POST INSTALLED ANCHORAGE INTO HARDENED CONCRETE OR MASONRY WHICH INCLUDES TYPES SUCH AS EXPANSION, WEDGE, SLEEVE, ADHESIVE/EPOXY, SHOT-PIN, SCREW AND UNDERCUT. 2. INSTALL PER THE MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS (MPII) EXCEPT AS OTHERWISE STATED IN THE SPECIFIED PRODUCT REPORTS. USE INSTALLATION PROCEDURES FOR CRACKED CONCRETE CONDITIONS. DO NOT USE CORE DRILL BITS FOR ANCHOR HOLES WITHOUT PRIOR SEOR APPROVAL. COPIES OF INSTALLATION INSTRUCTIONS SHALL BE MAINTAINED ON SITE. 3. PROVIDE GALVANIZED CARBON STEEL ANCHORS AT DRY INTERIOR LOCATIONS AND STAINLESS STEEL TYPE 304 OR 316 AT EXTERIOR / DAMP INTERIOR LOCATIONS. DOWELS TO RECEIVE CONCRETE COVER MAY BE PLAIN CARBON STEEL. ANCHORS SHALL BE CLEAN AND FREE OF DEBONDING SUBSTANCES. 4. UNLESS OTHERWISE NOTED, THE SPECIFIED EMBEDMENT REFERS TO THE FINAL INSTALLED EFFECTIVE DEPTH “Hef” AS DEFINED IN THE PRODUCT REPORT. MINIMUM ANCHOR HOLE DEPTH FOR INSTALLATION MAY BE DEEPER. FOR EXPANSION ANCHORS PROVIDE A MINIMUM ANCHOR HOLE DEPTH PER THE MPII, BUT NOT LESS THAN THE SPECIFIED EMBEDMENT + THE SMALLER OF 1.5x DIAM OR 1 INCH. WHERE EMBEDMENT IS NOT SPECIFIED, PROVIDE AN EMBEDMENT DEPTH OF THE SMALLER OF 8 TIMES THE ANCHOR DIAMETER AND 2/3 THE THICKNESS OF THE MEMBER THE ANCHOR IS PLACED INTO. 5. MAINTAIN A MINIMUM OF 2 INCHES FROM EXISTING REINFORCEMENT, CONDUIT, POST TENSIONING (WHERE OCCURS), ETC. PRIOR TO DRILLING, CORING OR SHOOTING PINS INTO EXISTING CONCRETE OR MASONRY USE NON DESTRUCTIVE TESTING TO LOCATE SUCH ITEMS. FOR INSTALLATION DEEPER THAN 3 INCHES USE GROUND PENETRATING RADAR OR X-RAY METHODS. 6. WHERE THE SPECIFIED ANCHOR EMBEDMENT DEPTH, SPACING OR EDGE DISTANCE CANNOT BE PROVIDED, NOTIFY THE SEOR AND lOR. 7. PATCH ABANDONED HOLES AND SPALLS USING NON-SHRINK GROUT AND REPAIR FINISHES AS REQUIRED. ANCHORS PENETRATING THROUGH WATER PROOFING OR VAPOR MEMBRANES SHALL BE SEALED OR FLASHED. 8. INSTALL IN DRY CONCRETE OR MASONRY HAVING A MINIMUM AGE OF 21 DAYS UNLESS SPECIFICALLY APPROVED BY THE SEOR. 9. ADHESIVE/EPOXY ANCHORS ON THIS PROJECT ARE NOT DESIGNED TO SUPPORT, OR INTENDED TO RESIST SUSTAINED TENSION LOADS. 10. INSTALLERS PLACING OVERHEAD ADHESIVE ANCHORS SHALL BE CERTIFIED BY ACI OR APPROVED EQUIVALENT. DO NOT PLACE POST INSTALLED ANCHORS IN CMU WITHIN 1 1/2” OF HEAD JOINTS OR INTO UNGROUTED CELLS UNLESS SPECIFICALLY INDICATED ON THE STRUCTURAL DOCUMENTS. STRUCTURAL CONCRETE CONT No. 6250 FFOHSIB RYAN W. REGISTEREDPROFESSIONALENGINEER STRUCTURALSTATEOFCALIFORNIA DATE: FOR BRANDOW & JOHNSTON STRUCTURAL+CIVIL ENGINEERS (B&J HBK, INC.) 3300 IRVINE AVE. SUITE 245 NEWPORT BEACH, CALIFORNIA 92660 T:(949)862-8500 WWW.BJSCE.COM JOB#: 1 7 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 a r c h i t e c t u r e i n t e r i o r d e s i g n p l a n n i n g DA I M L E R A C P L 30 0 9 D A I M L E R S T SA N T A A N A , C A 9 2 7 9 5 S0.2 GENERAL NOTES 07/23/24 NO. REMARKS DATE 60% COMPLETE SET 05/28/24 90% COMPLETE SET 07/12/24 ISSUE FOR BID 07/16/24 CITY SUBMITTAL 07/23/24 3009 S Daimler St 11/18/2024 STEEL WELDING 1. WELDING PROCEDURES, ELECTRODES AND WELDER QUALIFICATIONS SHALL CONFORM TO THE “CODE FOR WELDING IN BUILDING CONSTRUCTION,” AMERICAN WELDING SOCIETY (AWS), D1.1 AND THE AISC "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS” 2. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AWS STANDARD QUALIFICATION TESTS, AND SHALL BE CERTIFIED FOR THE WORK THEY ARE PERFORMING IN ACCORDANCE WITH THE AUTHORITY HAVING JURISDICTION. 3. PROJECT WELDING SHALL BE PERFORMED ONLY IN ACCORDANCE WITH WELDING PROCEDURE SPECIFICATIONS (WPS) SUBMITTED BY THE CONTRACTOR AND REVIEWED BY THE SEOR AND PROJECT WELDING INSPECTOR. THE WPS SHALL BE IN ACCORDANCE WITH AWS D1.1-D1.4 CURRENT EDITION. 4. WELDING OF STRUCTURAL STEEL SHALL BE PERFORMED PER AWS D1.1 USING E70XX ELECTRODES UNLESS OTHERWISE NOTED. 5. WELDING OF REINFORCING BARS SHALL BE PERFORMED PER AWS D1.4 USING E90XX ELECTRODES. 6. WELDING OF METAL DECK AND LIGHT GAGE STEEL SHALL BE IN ACCORDANCE WITH AWS D1.3. 7. WHERE WELDED METAL DECK ATTACHMENTS ARE SPECIFIED TO STEEL SUPPORTS USE PUDDLE WELDS OR WELDED STUDS SPACED AS NOTED. EFFECTIVE AREA OF PUDDLE WELDS SHALL BE NOT LESS THAN 1/2” EFFECTIVE DIAMETER AND FOR SEAM WELDS NOT LESS THAN 3/8” WIDE BY 1” LONG. 8. WELDS SHALL BE TESTED PER AWS D1.1 WITH MAGNETIC PARTICLE TESTING AT A RATE OF 10% UNLESS NOTED OTHERWISE. 9. ALL FULL PENETRATION WELDS SHALL BE TESTED PER AWS D1.1 WITH ULTRASONIC TESTING. ALL CJP GROOVE WELDS SHALL BE ULTRASONICALLY TESTED IN MATERIAL 5/16" THICK OR GREATER. FILLET WELDS AND PARTIAL PENETRATION SHALL BE TESTED BY MAGNETIC PARTICLE (MT) AT A RATE OF 40%. 10. ALL GROOVE OR BUTT WELDS SHALL BE COMPLETE PENETRATION WELDS, UNO. EXPOSED BUTT WELDS SHALL BE GROUND SMOOTH. 11. ALL EXPOSED WELDS ON ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALL COMPLY WITH AISC CODE OF STANDARD PRACTICE, SECTION 10. 12. FIELD WELDS HAVE BEEN INDICATED WHERE THEY ARE EXPECTED TO OCCUR. THE CONTRACTOR SHALL DETERMINE THE ACTUAL FIELD WELDING NECESSARY TO COMPLETE THE PROJECT AND INCLUDE ALL ASSOCIATED COSTS WITHIN THE BASE PRICE. 13. REMOVE ALL WELD TABS AND WELD BACKING BARS UNLESS NOTED OTHERWISE. WHERE BACKING IS REMOVED THE WELD ROOT SHALL BE BACKGOUGED TO SOUND METAL AND FILLED WITH WELD METAL. HIGH STRENGTH BOLTS 1. UNLESS NOTED OTHERWISE WHEN BOLTING STEEL COMPONENTS, BOLTS 3/4” DIAMETER AND LARGER SHALL BE ASTM A325 / F1852 HIGH STRENGTH, BOLTS 5/8" DIAMETER AND SMALLER SHALL BE A307. 2. JOINT ASSEMBLIES USING HIGH-STRENGTH BOLTS SHALL BE IN ACCORDANCE WITH THE CURRENT EDITION OF THE "AISC (RCSC) SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH-STRENGTH BOLTS". 3. HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM A325 / F1852 OR ASTM A490 / F2280 AS INDICATED, TYPE 1 OR 3, NUTS SHALL CONFORM TO ASTM A563 GRADE DH OR A194 GR 2H, AND WASHERS SHALL CONFORM TO ASTM F436 WITH GRADE, TYPE AND FINISH TO MATCH THE SPECIFIED BOLT. 4. PAINT SHALL NOT BE PERMITTED ON CONTACT SURFACES UNLESS NOTED OTHERWISE. CONTACT SURFACES OF BOLTED PARTS SHALL BE DESCALED AND FREE OF DIRT, OIL, BURRS, PITS, AND OTHER DEFECTS WHICH PREVENT SOLID SEATING OF PARTS. 5. ALL HIGH STRENGTH BOLTS SHALL BE TIGHTENED TO THE AISC SNUG TIGHT CONDITION UNLESS SPECIFIED AS SLIP- CRITICAL (SC). 6. SLIP-CRITICAL BOLTS SHALL HAVE CLASS "A" FAYING SURFACES. SLIP-CRITICAL JOINT ASSEMBLIES SHALL BE FULLY PRE- TENSIONED BY TURN-OF-NUT TIGHTENING, CALIBRATED WRENCH TIGHTENING, TENSION CONTROL BOLT ASSEMBLIES CONFORMING TO ASTM F1852 / F2280, OR BY DIRECT TENSION INDICATOR WASHERS CONFORMING TO ASTM F959. 7. HIGH STRENGTH BOLT ASSEMBLIES PERMANENTLY EXPOSED TO WEATHER OR MOISTURE SPECIFIED AS ASTM A325 / F1852 SHALL BE TYPE 1 GALVANIZED PER ASTM F2329 OR B695, AND ASTM A490 / F2280 SHALL BE TYPE 3 PLAIN WITH GRADE DH3 NUTS. STRUCTURAL STEEL SCHEDULE 62 65 58 60 60 58 - 35 - 36 B7 - 58 58 36 OR 55 WELDABLE A 36 50 B - A193 A36 F1554 A307 A53 A1085 HIGH STRENGTH ROD THREADED RODS ANCHOR ROD, ANCHOR BOLTS MACHINE BOLTS PIPE WHEN NOTED AS GR 50 50 46 50 65 36 C C 65 - - A500 A500 A572 A36 MIN Fu (ksi) MIN Fy (ksi)GRADEASTM ROUND SQUARE OR RECTANGULAR HOLLOW STRUCTURAL SECTION (HSS) WHEN NOTED AS GR 65 58 A992 65 TYPICAL UNO PLATE, ANGLE & CHANNEL (PL, L, C, MC) WIDE FLANGE (W, M, & S) & TEE SHAPE 62 1. DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE SPECIFICATIONS AND STANDARDS OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), AS CONTAINED IN THE LATEST EDITION OF "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" AISC 360, AND “CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES” AISC 303. 2. STEEL TYPE SHALL BE AS SPECIFIED IN THE STRUCTURAL STEEL SCHEDULE UNLESS NOTED OTHERWISE. 3. ALL CONNECTIONS NOT SHOWN SHALL CONFORM TO THE "AISC MANUAL OF STEEL CONSTRUCTION" AND SHALL BE SUBMITTED ON SHOP DRAWINGS FOR REVIEW BY SEOR PRIOR TO FABRICATION. 4. FABRICATOR SHALL BE LICENSED IN CONFORMANCE WITH THE BUILDING CODE AND IN ACCORDANCE WITH THE AUTHORITY HAVING JURISDICTION. ANY FABRICATOR SUPPLYING MORE THAN 1 TON OF STEEL SHALL BE AISC CERTIFIED. 5. ALL STRUCTURAL AND MISCELLANEOUS STEEL PERMANENTLY EXPOSED TO WEATHER OR MOISTURE SHALL BE HOT DIP GALVANIZED PER ASTM A123 AFTER FABRICATION UNLESS A WEATHER PROOF COATING IS SPECIFIED. STEEL IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED. STAINLESS AND WEATHERING STEELS WHERE SPECIFIED ARE EXEMPT. 6. BOLT AND THREADED ROD ASSEMBLIES PERMANENTLY EXPOSED TO WEATHER OR MOISTURE SHALL BE HOT DIP GALVANIZED PER ASTM F2329 UNLESS A FIELD APPLIED WEATHER PROOF COATING IS SPECIFIED. GALVANIZED NUTS ARE TO BE OVERTAPPED WHERE REQUIRED TO AVOID STRIPPING. GALVANIZED BOLT ASSEMBLIES SHALL BE LUBRICATED AND TESTED PRIOR TO SHIPMENT. ALL THREADED COMPONENTS OF FASTENER ASSEMBLY SHALL BE GALVANIZED USING THE SAME PROCESS. 7. COATED STEEL SURFACES SHALL BE PROTECTED DURING CONSTRUCTION AND REPAIRED AS REQUIRED. 8. USE THE APPROPRIATE NUT AND WASHER TYPE, GRADE AND FINISH FOR THE SPECIFIED BOLT. BOLTS WITH UPSET THREADS ARE NOT ALLOWED UNLESS EXPLICITLY SPECIFIED. PROVIDE ASTM A194 GR 2H NUTS WITH ASTM A193 GR B7 THREADED ROD. 9. PLACE NONSHRINK GROUT UNDER ALL BASE PLATES AND ALLOW TO CURE BEFORE APPLYING LOADS. INDICATE GROUT VENT HOLES ON SHOP DRAWINGS WHERE REQUIRED. PRIMED OR PLAIN STEEL TO BE IN DIRECT CONTACT WITH NONSHRINK GROUT SHALL BE CLEANED TO BARE METAL BEFORE GROUTING. 10. FOR STEEL EMBEDDED IN CONCRETE OR MASONRY WHICH WILL INTERFERE WITH CONTINUOUS REINFORCING BARS, REQUEST CLARIFICATION FROM THE SEOR WHETHER TO PROVIDE HOLES FOR PASSAGE. DO NOT CUT HOLES IN STRUCTURAL STEEL WITHOUT PRIOR APPROVAL OF SEOR. 11. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL STEEL FEATURES SUCH AS TABS, STUDS, WEEP HOLES OR OTHER ITEMS NOT SHOWN. 12. ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALL COMPLY WITH AISC CODE OF STANDARD PRACTICE, SECTION 10. 13. WELDED HEADED STUDS, THREADED STUDS, AND DEFORMED BARS SHALL COMPLY WITH ASTM A108 OR A496 TYPE C BY NELSON, OR EQUIVALENT, AND WELDED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS BY CERTIFIED WELDERS SO AS TO FULLY DEVELOP THE TENSILE CAPACITY OF THE CONNECTOR. 14. EMBEDDED ENDS OF ANCHORS IN CONCRETE OR GROUTED CMU SHALL BE HEADED OR HAVE DOUBLE NUTS LOCKED AGAINST EACH OTHER, UNO ON DRAWINGS. MATERIALS AND SYMBOLS LFRS STEEL LATERAL FORCE RESISTING SYSTEM, SEE SHEET S001 AND SPECIFICATIONS SHEET REFERENCE SECTION OR DETAIL FULL HEIGHT SECTION WALL OR FRAME ELEVATION FINISH ELEVATION SHEET REFERENCE NUMBER REFERENCE SHEET REFERENCE NUMBER REFERENCE REFER TO PLANS FOR DATUM NUMBER REFERENCE MATERIALS CONCRETE CONCRETE BLOCK EARTH SYMBOLS STEEL 1. DESIGN, FABRICATION AND ERECTION OF COLD-FORMED STEEL FRAMING SHALL CONFORM TO THE CURRENT CBC ADOPTED EDITION OF THE SPECIFICATIONS AND STANDARD OF THE AMERICAN IRON AND STEEL INSTITUTE (AISI), AS CONTAINED IN THE "SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS", INCLUDING ALL APPLICABLE AMENDMENTS. 2. ALL COLD-FORMED STEEL FRAMING SHALL BE ERECTED PLUMB AND TRUE TO LINE. TEMPORARY BRACING SHALL BE INSTALLED AND LEFT IN PLACE UNTIL OTHER MEANS IS PROVIDED TO ADEQUATELY BRACE THE STRUCTURE. ALL COLD-FORMED STEEL FRAMING SHALL BE BRACED AS REQUIRED BY SECTION D3 OF THE AISI SPECIFICATION. 3. COLD-FORMED STEEL GRADES (ASTM A1003): 18 GA (43 MILS) OR THINNER.........................................................................................................................GRADE 33 (Fy = 33 KSI) 16 GA (54 MILS) AND THICKER.......................................................................................................................GRADE 50 (Fy = 50 KSI) 4. SUBMIT COLD-FORMED STEEL FRAMING SHOP DRAWINGS AND SPECIFICATIONS TO THE SEOR AND AOR FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. 5. COLD-FORMED STEEL STUDS AND TRACKS ARE TO BE ATTACHED WITH SHEET METAL SCREWS (SMS) WITH SIZES CALLED OUT ON THE DETAILS. PENETRATION OF SCREWS THROUGH JOINED MATERIAL SHALL NOT BE LESS THAN 3 EXPOSED THREADS. SCREWS ARE TO BE INSTALLED AND TIGHTENED IN ACCORDANCE WITH SCREW MANUFACTURER'S RECOMMENDATIONS. SHEET METAL SCREWS SHALL COMPLY WITH ASTM C1513, SELF-DRILLING AND TAPPING TYPE, WITH PANCAKE FRAMER HEAD TYPE FOR #10 SMS AND HEX WASHER HEAD TYPE FOR #12 AND # 14 (1/4"Ø) SMS UNLESS NOTED OTHERWISE. 6. COLD-FORMED STUD MEMBERS SHALL BE UNPUNCHED WHERE USED FOR THE FOLLOWING: HEADERS AND SILLS OF OPENINGS WIDER THAN 3'-0", AND BUILT-UP BOX AND BACK-TO-BACK SECTIONS. PUNCH-OUTS SHALL BE LOCATED IN THE CENTER OF THE WEB WITH A MINIMUM SPACING OF 24"OC, HAVE A MAXIMUM WIDTH OF HALF THE MEMBER DEPTH OR 2 1/2", WHICHEVER IS LESS, AND A MAXIMUM LENGTH OF 4 1/2". THE MINIMUM DISTANCE BETWEEN THE END OF THE MEMBER AND THE NEAR EDGE OF THE PUNCH-OUT SHALL BE 12". WELDING OF LIGHT GAGE STEEL SHALL BE IN ACCORDANCE WITH AMERICAN WELDING SOCIETY (AWS) D1.3. COLD-FORMED STEEL FRAMING STRUCTURAL STEEL No. 6250 FFOHSIB RYAN W. REGISTEREDPROFESSIONALENGINEER STRUCTURALSTATEOFCALIFORNIA DATE: FOR BRANDOW & JOHNSTON STRUCTURAL+CIVIL ENGINEERS (B&J HBK, INC.) 3300 IRVINE AVE. SUITE 245 NEWPORT BEACH, CALIFORNIA 92660 T:(949)862-8500 WWW.BJSCE.COM JOB#: 1 7 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 a r c h i t e c t u r e i n t e r i o r d e s i g n p l a n n i n g DA I M L E R A C P L 30 0 9 D A I M L E R S T SA N T A A N A , C A 9 2 7 9 5 S0.3 GENERAL NOTES 07/23/24 ABBREVIATIONS A AB ANCHOR BOLT ADDL ADDITIONAL ADJ ADJACENT AFF ABOVE FINISH FLOOR ALT ALTERNATE ARCH ARCHITECT(URAL) B BLDG BUILDING BLKG BLOCKING BM BEAM BN BOUNDARY NAILING BO BOTTOM OF BOTT, (B) BOTTOM BTWN BETWEEN C C CAMBER CIP CAST IN PLACE CJ CONTROL/CONSTRUCTION JOINT CJP, CP COMPLETE JOINT PENETRATION CL CENTERLINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONN CONNECTION CONT CONTINUOUS CTR(D) CENTER(ED) CY CUBIC YARDS D DB BAR DIAMETER DBL DOUBLE DC DEMAND CRITICAL DEMO DEMOLISH, DEMOLITION DIA, DIAM DIAMETER DIAG DIAGONAL DIM DIMENSION DO DITTO DWG DRAWING E EA EACH EF EACH FACE EJ EXPANSION JOINT ELEC ELECTRICAL ELEV ELEVATION, ELEVATOR EMBED EMBEDMENT EN EDGE NAIL EO EDGE OF EQ EQUAL EQUIP EQUIPMENT ES EACH SIDE EW EACH WAY EXIST, (E) EXISTING EXP EXPANSION EXT EXTERIOR F FLR FLOOR FN FIELD NAILING FND FOUNDATION FO FACE OF FS FAR SIDE FT FOOT, FEET FTG FOOTING G GA GAUGE GALV GALVANIZED GC GENERAL CONTRACTOR GLBM, GB GLUED-LAMINATED BEAM GR GRADE GRBM GRADE BEAM H HK HOOK HORIZ HORIZONTAL HS HIGH STRENGTH HSS HOLLOW STRUCTURAL SECTION HT HEIGHT I ID INSIDE DIAMETER IN INCH INT INTERIOR ABBREVIATIONS J JT JOINT K K, KIP(S) KILOPOUND KLF KIPS PER LINEAR FOOT KSF KIPS PER SQUARE FOOT KSI KIPS PER SQUARE INCH L L ANGLE LB, LBS POUND(S) LF LINEAR FEET LFRS LATERAL FORCE RESISTING SYSTEM LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL M MAX MAXIMUM MB MACHINE BOLT MECH MECHANICAL MFR MANUFACTURE MIN MINIMUM MW MEDIUM WEIGHT N (N) NEW NDT NON-DESTRUCTIVE TESTING NS NEAR SIDE NTS NOT TO SCALE NW(C) NORMAL WEIGHT (CONCRETE) O OC ON CENTER OD OUTSIDE DIAMETER OH OPPOSITE HAND OPP OPPOSITE P PAF, PDF POWDER DRIVEN/POWER ACTUATED FASTENER PJP, PP PARTIAL JOINT PENETRATION PL PLATE PLF POUND PER LINEAR FOOT PSF POUND PER SQUARE FOOT PSI POUND PER SQUARE INCH PT PRESSURE TREATED WOOD, POST/PRE-TENSIONED R R RADIUS REF REFERENCE REINF REINFORCING REQD REQUIRED S (S)EOR (STRUCTURAL) ENGINEER OF RECORD SC SLIP CRITICAL SCHED SCHEDULE SDS, SMS SELF-DRILLING / SHEET METAL SCREW SFRS SEISMIC FORCE RESISTING SYSTEM SIM SIMILAR SN SILL NAILING SOG SLAB ON GRADE SPECS SPECIFICATIONS SQ SQUARE SS STAINLESS STEEL STD STANDARD STIFF STIFFENER STL STEEL STRUCT STRUCTURAL SYM SYMMETRICAL T T&B TOP & BOTTOM TO TOP OF TYP TYPICAL U UNO UNLESS NOTED OTHERWISE V VERT VERTICAL VIF VERIFY IN FIELD W W/ WITH W/O WITHOUT WF WIDE FLANGE WP WORK POINT WT WEIGHT WWF WELDED WIRE FABRIC NO. REMARKS DATE 60% COMPLETE SET 05/28/24 90% COMPLETE SET 07/12/24 ISSUE FOR BID 07/16/24 CITY SUBMITTAL 07/23/24 3009 S Daimler St 11/18/2024 TYPICAL CARBON STEEL ANCHOR INSTALLATION DESIGN AND TEST VALUES BOLT DIAMETER MIN. EMBEDMENT MIN. HOLE DEPTH 3/8" 2" 2 5/8" MIN MEMBER THICKNESS 4" INSTALLATION TORQUE 25 FT-LBS 1/2" 2" 2 5/8" 4" 5/8" 3 1/8" 3 7/8" 5" 3/4" 3 3/4" 4 5/8" 6" 3 1/4" 4" 6" 4" 4 3/4" 6" 4 3/4" 5 3/4" 8" 40 FT-LBS 60 FT-LBS 110 FT-LBS ANCHOR AT WALL OR SLAB EMBEDMENT 1" MIN HOLE DEPTH USE STEEL PIECE AS TEMPLATE ANCHOR RELOCATION DETAIL 1 1/4" MIN RELOCATE HOLE SLIGHTLY 1/4 1/4 OPPOSITE EDGES EDGE OF STEEL PLATE 3" SQx1/4" PLATE NOTE: RELOCATE BOLT IF REQ'D TO CLR REINF STEEL CONC UNLESS NOTED/ REFERENCED ON THE DETAILS/DRAWINGS, THIS DETAIL CAN NOT BE USED TO REPLACE CAST-IN-PLACE ANCHORS WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. INSTALLATION: 1. ALLOWABLE WEDGE ANCHOR TYPES: PER PRODUCT SCHEDULE. 2. UNO INSTALL ANCHORS PER MANUFACTURER'S RECOMMENDED SPECIFICATIONS. 3. THE TABULATED INSTALLATION AND TEST VALUES PERTAIN TO USE IN HARDROCK CONCRETE, LIGHT-WEIGHT CONCRETE AND CONCRETE FILL OVER METAL DECK. CONCRETE FILL OVER METAL DECK SHALL CONSIST OF 20GA. MIN. METAL DECK WITH EITHER HARD ROCK OR LIGHT WEIGHT CONCRETE. CONCRETE SHALL HAVE A MINIMUM STRENGTH OF 3000 PSI. 4. WHEN INSTALLING DRILLED-IN ANCHORS IN NON-PRESTRESSED REINFORCED CONCRETE, USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE REINFORCING BARS OR OTHER EMBEDDED ITEMS SUCH AS ELECTRICAL/TELECOMMUNICATIONS CONDUIT AND GAS LINES. WHEN INSTALLING DRILLED-IN ANCHORS INTO PRESTRESSED CONCRETE (PRE OR-POST-TENSIONED). LOCATE TENDONS DURING INSTALLATION. MAINTAIN A MINIMUM CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR. 5. DRILLED EXPANSION TYPE ANCHOR BOLTS SHALL BE USED ONLY WHERE DETAILED OR FOR ATTACHMENT OF MECH, ELEC, OR MISC ACCESSORIES OR EQUIPMENT TO THE STRUCTURE. 6. WHERE EDGE DISTANCE AND SPACING IS NOT SHOWN ON DETAILS, REFER ICC ESR REPORT FOR MINIMUM VALUES. EQEQ LAP 18" MIN SAWCUT AND REMOVE EXISTING SLAB AS REQUIRED FOR INSTALLATION OF UTILITY LINES (E)SOG CONCRETE SLAB SEE NOTE 5 4" M I N SEE NOTE 4 UTILITY LINE AS REQUIRED NOTES: 1. VERIFY IN FIELD ALL (E)INFORMATION. 2. SAW-CUTTING SHALL BE AVOIDED NEAR ANY OF THE (E)PAD FOOTINGS, GRADE BEAMS AND CONT FOOTINGS. 3. WHERE REPLACEMENT OF WATERPROOFING IS REQUIRED BELOW THE SLAB ON GRADE, SAW CUT AN ADDITIONAL WIDTH OF SLAB ON GRADE AS REQUIRED WITHOUT DAMAGING THE EXISTING WATERPROOFING. 4. BACKFILL WITH CONTROLLED COMPACTED FILL OR LEAN CONCRETE AT CONTRACTOR'S OPTION OR PER RECOMMENDATIONS FROM GEOTECHNICAL REPORT IF AVAILABLE. 5. REBAR TO MATCH (E)SIZE AND SPACING IN BOTH DIRECTIONS (#4@18"OC MIN). HOOK BARS WHERE LAP CANNOT BE ACHIEVED. INSTALL REBAR IN EPOXY ADHESIVE PER TYPICAL EPOXY DETAIL. SPECIAL INSPECTION IS NOT REQUIRED UNLESS NOTED ON THE PLANS. 6. FOR ANY SLAB ON GRADE SAW-CUTTING THAT IS NOT SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ARCHITECT SHOWING LOCATION, WIDTH, DEPTH AND LENGTH OF TRENCH PRIOR TO CUTTING THE SLAB. SIZE OF TRENCH WILL BE AS REQ'D BY ELECTRICAL OR PLUMBING. 2" NEW OPENING IN EXISTING SLAB OR WALL. REFER TO ARCH DWGS FOR DIMENSIONS CORE 4" DIA HOLE BEFORE SAWCUTTING OPENING(TYP 4 CORNERS) PLAN DETAIL SECTION (E)FRAMED SLAB OR WALL LIMIT OF SAWCUT (OVERCUTTING NOT PERMITTED) HAND CHIP TO FORM NEAT CORNER IF REQ'D NOTE: UNLESS NOTED ON THE DWGS, THIS DETAIL CAN NOT BE USED WITHOUT THE APPROVAL OF ARCH & SEOR. CUTTING BLADE2" PE R S C H E D PER SCHEDPER SCHED AL L A R O U N D 1" G R O U T MASONRY CONCRETE ELEVATED SLAB OR SLAB ON GRADE HEADED STUD CAST IN PLACE ANCHORS DIAMETER 1/4" MIN EMBED UNO 2 1/2" 3/8" 3" 1/2" 4" 5/8" 4 1/2" 3/4" 5" 7/8" 6" 1" 7" 1 1/8" 8" 1 1/4" 9" CAST IN PLACE ANCHOR NOTES: 1. ALL HORIZONTAL CAST IN PLACE ANCHORS SHALL BE HEADED STUDS 2. MINIMUM CONCRETE COMPRESSIVE STRENGTH OF 2500 PSI SLAB ONGRADE BOTTOM OF EQUIPMENT LEG W/ MOUNTING HOLES ANCHOR PER SCHEDULE 13 S1.1 NOTE: 1. ANCHOR LAYOUT PER MANUFACTURER 2. DRILL OUT ANCHOR HOLE AS REQUIRED ADIRECT CONNECTION BRESTRAINT CONNECTION SLAB ONGRADE 1 1/2" TYP 3/16 ALT TO SMS EQUIPMENT L3x2x1/4x0'-3" (LLH) AT EACH CORNER (MIN 4 TOTAL) (3)-#10 SMS ATTACHMENT ANCHORAGE PER SCHEDULE CANCHORAGE CONNECTION SLAB ONGRADE 3" MAX 13 S1.1 1 1/2" TYP 1" M A X 3/8" A36 PLATE 3/8" A36 PLATE SLAB ONGRADE 1 1/2" TYP ANCHORAGE PER SCHEDULE 13 S1.1 ANCHORAGE PER SCHEDULE 13 S1.1 1" MIN 3/16 1" REBAR SIZE, ASTM A615 GRADE 60 1/2" 5/8" MIN HOLE DIAM #3 #4 3/4"#5 1"#6 MIN DEPTH DOWEL NOTES: 1. ALLOWABLE EPOXY TYPES: HILTI RE 500 V3 (ICC ESR-3814), HILTI HIT-HY 200 (ICC ESR-3187) 2. UNO INSTALL PER MANUFACTURER'S RECOMMENDED SPECIFICATIONS. HOLE SHALL BE THOROUGHLY CLEANED AND ANCHOR SHALL BE FREE OF ANY MATERIAL THAT SHALL IMPAIR BOND TO CONCRETE. 3. THE TABULATED INSTALLATION AND TEST VALUES PERTAIN TO USE IN HARDROCK CONCRETE WITH A MINIMUM STRENGTH OF 3,000 PSI. 4. WHEN INSTALLING DRILLED-IN ANCHORS IN NON-PRESTRESSED REINFORCED CONCRETE, USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE REINFORCING BARS OR OTHER EMBEDDED ITEMS SUCH AS ELECTRICAL/TELECOMMUNICATIONS CONDUIT AND GAS LINES. WHEN INSTALLING DRILL-IN ANCHORS INTO PRESTRESSED CONCRETE (PRE OR POST-TENSIONED), LOCATE TENDONS DURING INSTALLATION BY USING A NON- DESTRUCTIVE METHOD PRIOR TO INSTALLATION. EXERCISE EXTREME CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION. MAINTAIN A MINIMUM CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR. 5. DRILLED EPOXY ANCHORS SHALL BE USED ONLY WHERE DETAILED. 6. WHERE SPECIFIED ANCHOR EMBEDMENT DEPTH, SPACING OR EDGE DISTANCE CANNOT BE PROVIDED, NOTIFY SEOR AND IOR PRIOR TO INSTALLATION. 7. SPECIAL INSPECTION REQUIRED PER CBC TABLE 1705.3. 8. INSTALLERS PLACING HORIZONTALLY OR UPWARDLY INCLINED ORIENTATIONS ADHESIVE ANCHORS SHALL BE CERTIFIED BY ACI OR APPROVED EQUIVALENT. 9. ALL TESTS SHALL BE PERFORMED IN THE PRESENCE OF THE SPECIAL INSPECTOR OR INSPECTOR OF RECORD. 10. FOR LOCATIONS WHERE TENSION TEST VALUES ARE NOT SPECIFIED IN THE DRAWINGS, CONSULT WITH THE SEOR. 11. TESTING OF EPOXY DOWELS AT JOINTS BETWEEN NEW AND EXISTING SLABS-ON-GRADE OR #3 BARS AT CONCRETE CURBS IS NOT REQUIRED. 12. EPOXY DOWELS SHALL BE INSTALLED IN CONCRETE HAVING A MINIMUM AGE OF 21 DAYS AT TIME OF ANCHOR INSTALLATION. 3" 4" 6" 12" 2.8 KIPS 4.4 KIPS 5.8 KIPS 8.5 KIPS (PER SCHEDULE) MIN DIAM OF HOLE (PER SCHEDULE) MINIMUM DEPTH OF HOLE FACE OF EXISTING CONC SLOPED HOLE WHERE INDICATED NOTES: UNLESS NOTED/ REFERENCED ON THE DETAILS/DRAWINGS, EPOXY ANCHORS SHALL NOT BE USED TO REPLACE CAST-IN-PLACE ANCHORS. (TYP) 22.5° THREADED ROD DIAMETER, ASTM A36 TENSION TEST LOAD MIN HOLE DIAM MIN DEPTH TENSION TEST LOAD #7 #8 #9 1 1/8" 1 1/4" 1 3/8" 16" 18" 21" 5/8" 3/4" 7/8" 1/2" 1" 1 1/4" 8" 10" 11 1/4" 11.7 KIPS 13.8 KIPS 23.0 KIPS 9/16" 11/16" 13/16" 15/16" 3 1/2" 4 1/2" 6" 6 3/4" 2.5 KIPS 4.3 KIPS 5.8 KIPS 9.0 KIPS 1 1/16" 1 5/16" 11.5 KIPS 19.4 KIPS 22.9 KIPS 3/8" 7/16" db EPOXY EQUIPMENT ANCHORAGE SCHEDULE UNIT ANCHOR BOLTS DIA x EMBED QUANTITY REFERENCES UNIT WEIGHT UNIT 1/2"Ø3" (6) TOTAL 800 LBS UNIT UNIT (6) TOTAL (6) TOTAL 12 S1.1 12 S1.1 12 S1.1 800 LBS 800 LBS NOTE: 1. CURBS, ISOLATORS AND ALL CONNECTION REQUIRED FOR GRAVITY AND LATERAL RESTRAINT PER MECHANICAL/ELECTRICAL CONTRACTOR SEE MECHANICAL/ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION 2. COORDINATE EXACT HEIGHT, WIDTH AND LOCATIONS OF EQUIPMENT AND ANCHORS WITH MECHANICAL AND ELECTRICAL DRAWINGS 3. FOR ANCHORAGE SPECIFICATIONS REFER TO DETAILS THIS SHEET NOTE: REFER TO MANUFACTURER CUT SHEETS FOR EXACT SPACING OF REQUIRED ANCHORS SHOWN IN TABLE ABOVE 13 27 84 1/2"Ø3" 1/2"Ø3" No. 6250 FFOHSIB RYANW. REGISTEREDPROFESSIONALENGINEER STRUCTURALSTATEOFCALIFORNIA DATE: FOR BRANDOW & JOHNSTON STRUCTURAL+CIVIL ENGINEERS (B&J HBK, INC.) 3300 IRVINE AVE. SUITE 245 NEWPORT BEACH, CALIFORNIA 92660 T:(949)862-8500 WWW.BJSCE.COM JOB#: 1 7 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 a r c h i t e c t u r e i n t e r i o r d e s i g n p l a n n i n g DA I M L E R A C P L 30 0 9 D A I M L E R S T SA N T A A N A , C A 9 2 7 9 5 S1.1 TYPICAL CONCRETE DETAILS 09/25/24 SCALE: NTS S1.1 TYPICAL CONCRETE POST-INSTALLED ANCHOR 2 DETAIL ID: CR-AB-01 SCALE: NTS S1.1 TYPICAL TRENCH AT (E) SLAB ON GRADE 6 DETAIL ID: CR-RETRO-07 SCALE: NTS S1.1 TYPICAL SAWCUT OPENING 7 DETAIL ID: CON-SOGD-01 SCALE: NTS S1.1 TYPICAL CAST IN PLACE ANCHOR 8 SCALE: 1" = 1'-0"S1.1 EQUIPMENT ANCHORAGE DETAIL 12 SCALE: 1" = 1'-0"S1.1 TYPICAL HILTI EPOXY DOWEL ANCHOR DETAIL 4 DETAIL ID: CON-HILTI-03 SCALE: 1" = 1'-0"S1.1 EQUIPMENT ANCHORAGE SCHEDULE 13 NO. REMARKS DATE 60% COMPLETE SET 05/28/24 90% COMPLETE SET 07/12/24 ISSUE FOR BID 07/18/24 CITY SUBMITTAL 07/23/24 1 CITY RESUBMITTAL 09/24/24 1 3009 S Daimler St 11/18/2024 TYPICAL JAMB STUDS 6" M A X OPEN OPEN CONTINUOUS BRIDGING TYPICAL BRIDGING DETAIL CONTINUOUS BRIDGING @ 4'-0" MAX TYP STUD SIZE PER PLAN AND SCHEDULE NOTES: 1. USE 16 GA STUDS MINIMUM WHERE EQUIPMENTS, CABINETS, ELECTRICAL PANELS, ETC. REFER TO ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR LOCATIONS. 2. ALL STUDS ARE 16" OC UNLESS NOTED OTHERWISE. 3. WHERE WALLS HAVE CABINETS/CASEWORK ON BOTH SIDES, USE SPACING 12" OC WHERE 16" OC CALLED OUT. 4. BOTTOM TRACK SIZE AND GAGE TO MATCH WALL STUDS. 5. AT FULL HT TRACK FOR TYPE "C" JAMB, STOP TRACK 2" FROM FLOOR AND TOP TRACK TO AVOID INTERFERENCE WITH SILL AND TOP TRACKS. 6. REFER TO ARCHITECTURAL SPECIFICATIONS AND DRAWINGS FOR WALL THICKNESSES. 7. CONTRACTOR MAY USE PRO-X HEADERS (IAPMO REPORT # 0286) AT INTERIOR NON-LOAD BEARING CONDITIONS IN LIEU OF THIS DETAIL. FOLLOW ALL REQUIREMENTS AND ATTACH TO JAMB STUDS PER ICC REPORT. OH TYP TYP WALL TYPE SIZE & SPACING Fy (ksi) MAX HT 4-LAYERS OF 5/8" GYP TOTAL 3-LAYERS OF 5/8" GYP TOTAL 2-LAYERS OF 5/8" GYP TOTAL 1-LAYER OF 5/8" GYP TOTAL (1) 600S200-54@24" OC 600S162-43@16" OC 400S250-54@12" OC 600S162-54@24" OC 600S162-43@16" OC 400S200-54@12" OC 400S162-54@24" OC 362S162-33@16" OC 362S162-33@12" OC 362S162-33@16" OC 362S162-33@24" OC 50 33 50 50 33 50 50 50 33 33 50 15'-0" INTERIOR METAL STUD WALL ELEVATION BOTTOM TRACK FASTENER SCHEDULE INTERIOR PARTITIONS TYPICALLY 0.145" DIA POWDER DRIVEN PINS @ 32" OC OR 3/8" DIA ANCHORS INTERIOR PARTITIONS ADJACENT TO DEPRESSIONS OR CURBS 3/8" DIA ANCHORS @ 48" OC 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" TOP TRACK FULL HEIGHT TOP TRACK PARTIAL HEIGHT BOTTOM TRACK ANCHORAGE SCHEDULE B A C A TABLE NOTES: 1. WALL BRIDGING REQUIRED PER TYPICAL WALL BRIDGING DETAIL. PUNCHOUT NO CLOSER THAN DEPTH OF HEADER TO CONNECTION (TYP) C D MAX HEIGHT (SEE NOTE 4) MAXIMUM OPENING WIDTH TYPE JAMB SIZE 22'-0" OR LESS INTERIOR WALL OPENING SCHEDULE SCHEDULE A14'-0" 6'-0" 8'-0" 10'-0" A2 A2 A3 STUD SIZE TRACK SIZE 600S162-54 NONE TYPE SILL SIZE B1 B1 B1 NA STUD SIZE TRACK SIZE NONE 600T125-43 TYPE HEADER SIZE C2 C3 C3 C3 STUD SIZE TRACK SIZE 600S200-54 (2) 600T200-43 (2)600S162-43 NONE 600T125-43 NONE (2)600S182-54 NONE NONE 600T125-43 600T200-54 600T200-54 600T200-54 600T200-54 600T200-54 600T200-54 600T200-54 600T200-54 600T200-43 600T200-43 600T200-54 600T200-54 600T200-54 600T200-54 600T200-43 600T200-43 600T200-43 600T200-43 600T200-43 600T200-43 600T200-43 600T200-43 JAMB ANCHOR NOTES (2) 0.157Ø PSG W/3/4" EMBED OR (1) 3/8"Ø POST INSTALLED ANCHORS (2) 0.157Ø PSG W/3/4" EMBED OR (1) 3/8"Ø POST INSTALLED ANCHORS (2) 0.157Ø PSG W/3/4" EMBED OR (1) 3/8"Ø POST INSTALLED ANCHORS (2) 0.157Ø PSG W/3/4" EMBED OR (1) 3/8"Ø POST INSTALLED ANCHORS ONLY AT ROLL-UP DOORS 22'-0" OR LESS 22'-0" OR LESS 22'-0" OR LESS (3)600S182-68 NONE N/A N/A (2) 600T162-43 (2) 600T200-43 (2) 600T162-43 (2) 600T200-43 (2) 1000S162-54 (2) 600T200-43 TYPETYPETYPE UNPUNCHED JAMB STUD PARTIAL HEIGHT STUD TRACK PER SCHEDULE UNPUNCHED JAMB STUDS UNPUNCHED JAMB STUDS 1 2 3 INTERIOR JAMB STUD CONFIGURATION FULL HEIGHT STUD TRACK PER SCHEDULE A TYPE BACK-TO-BACK JAMB STUDS PER DETAIL 6" LONG SECTION OF STUD ATTACHED TO JAMB W/ (4)#10 SMS WHERE FULL HEIGHT TRACK DOES NOT OCCUR AT OPENING SIDE, CAP OPENING SIDE OF JAMB WITH A SECTION OF TRACK. EXTEND TRACK 12" PAST TOP AND BOTTOM OF OPENING ATTACH TO JAMB W/ (1)#10 SMS@16"OC IN EACH LEG. SILL TRACK TYPE ISOMETRIC SILL TO JAMB 1 2 &3 B (2)#10 SMS@16" OC (2)#10 SMS@16" OC HEAD AS REQUIRED L1 1/2x1 1/2x 14 GA STUD DEPTH W/ (2)#10 SMS EACH LEG FULL HEIGHT JAMB STUDS 1TYPE #10 SMS AT EACH FLANGE OF STUD ATTACH EACH TRACK TO STUD USING (2)#10 SMS@16"OC 6" LONG SECTION OF STUD ATTACHED TO JAMB W/ (4)#10 SMS CRIPPLE STUDS #10 SCREW TYP EACH FLANGE HEADER PER SCHEDULE EQUAL1/2" 1/2" 3/4" L1 1/2x1 1/2x14GA xSTUD DEPTH W/ (3)#10 SMS EACH LEG FULL HEIGHT JAMB STUDS WHERE FULL HEIGHT TRACK DOES NOT OCCUR AT OPENING SIDE, CAP OPENING SIDE OF JAMB WITH A SECTION OF TRACK. EXTEND TRACK 12" PAST TOP AND BOTTOM OF OPENING ATTACH TO JAMB W/ (1)#10 SMS @12"OC IN EACH LEG ISOMETRIC HEADER TO JAMB 2TYPE #10 SMS EACH FLANGE C 3/4" 1/2" 1/2" EQUAL (1)#10 SMS (TYP) EACH FLANGE HEADER PER SCHEDULE (2)#10 SMS @8"OC CRIPPLE STUDS 18GA MIN TRACK W/ (3)#10 SMS EACH FLANGE TO HEADER, AND (6)#10 SMS FROM WEB TO JAMB STUD FULL HEIGHT JAMB STUDS WHERE FULL HEIGHT TRACK DOES NOT OCCUR AT OPENING SIDE, CAP OPENING SIDE OF JAMB WITH A SECTION OF TRACK. EXTEND TRACK 12" PAST TOP AND BOTTOM OF OPENING ATTACH TO JAMB W/(1)#10 SMS@16"OC IN EACH LEG L1 1/2x1 1/2x14GA xSTUD DEPTH W/ (3)#10 SMS EACH LEG TOP AND BOTTOM 3TYPE #10 SMS@8"OC TOP TRACK CONFIGURATION CL R 3/ 4 " STRUCTURE ABOVE MA X 12 " TYPICAL BRIDGING TOP TRACK PER SCHEDULE WALL STUDS PER SCHEDULE NOTES: 1. NO CONNECTIONS OF ARCHITECTURAL FINISHES TO TOP TRACK. 2. DO NOT CONNECT STUDS TO TOP TRACK. D SPAN (2)#10 SMS EACH STUD CONT. 16 GA TRACK ATTACH DIRECTLY TO STUD #10 SMS EACH LEG EACH JOIST CONT 150450-54 BRIDGING WITH #10 SMS AT EACH JOIST SEE SCHEDULE JOIST PER SCHEDULE (3) #10 SMS TYPICAL ALTERNATE CEILING JOIST PER PLAN 1 TO 2 LAYERS BOARD (2 - 5/8" MAX)STUDS (3)#10 SMS SMS EACH STUD (2)#10 SMS BLOCKING PER METAL STUD PER PLANXXXT150-54 CONT TRACK W/ #10 SMS EACH SIDE ATTACHMENT TO TYP BOARD WALL JOIST CONTINUOUS OVER TOP OF WALL B C D (2)#10 SMS CONT RIM JOIST METAL STUD PER PLAN XXXT150-54 CONT TRACK W/ #10 SMS EACH SIDE END BEARING CONDITION AT TOP OF WALL E CEILING JOIST SCHEDULE SECTION 12 UNSUPPORTED MIDSPAN JOIST SPACING JOIST SPACING (in) ON CENTER (in) ON CENTER 16 12 16 Fy (ksi) 362S162-33 33 TABLE NOTE; 1. ONE LAYER OF 5/8" GYP BOARD WEIGHS 2.5 PSF 2. CONFIRM ALLOWABLE SPANS FOR FINISHES WITH ARCHITECT A 9'-0" 8'-3" 12'-6" 11'-3" 400S162-33 33 10'-0" 9'-0" 13'-0" 12'-0" 600S162-33 33 16'-0" 14'-0" 18'-0" 16'-6" INTERIOR STUD PER TYP INTERIOR METAL STUD WALL CONSTRUCTION DETAIL ELEVATED DECK OR SLAB ON GRADE- SEE PLAN 3/8" DIA x 2" EMBED @ 4'-0" OC PER TYPICAL POST INSTALLED ANCHOR INTO CONCRETE FILLED DETAIL CURB CONDITION NO CURB CONDITION 2 3/4" 9" M A X INTERIOR STUD PER TYP INTERIOR METAL STUD WALL CONSTRUCTION DETAIL CURB AND REINFORCING PER TYP CONCRETE PAD AND CURB ON METAL DECK DETAIL NOTE: EMBEDMENT OF ANCHOR FOR TRACK MEASURED FROM BOTTOM OF CURB, NOT TOP OF CURB 6" MIN ELEVATED DECK OR SLAB ON GRADE - SEE PLAN No. 6250 FFOHSIB RYAN W. REGISTEREDPROFESSIONALENGINEER STRUCTURALSTATEOFCALIFORNIA DATE: FOR BRANDOW & JOHNSTON STRUCTURAL+CIVIL ENGINEERS (B&J HBK, INC.) 3300 IRVINE AVE. SUITE 245 NEWPORT BEACH, CALIFORNIA 92660 T:(949)862-8500 WWW.BJSCE.COM JOB#: 1 7 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 a r c h i t e c t u r e i n t e r i o r d e s i g n p l a n n i n g DA I M L E R A C P L 30 0 9 D A I M L E R S T SA N T A A N A , C A 9 2 7 9 5 S1.2 STEEL STUD DETAILS 07/23/24 SCALE: 1/2" = 1'-0"S1.2 TYPICAL INTERIOR METAL STUD WALL CONSTRUCTION 4 DETAIL ID: CS-ISTUD-01 SCALE: 1" = 1'-0"S1.2 TYPICAL CEILING JOIST CONNECTION DETAIL 15 DETAIL ID: CS-STUD-23 SCALE: 1" = 1'-0"S1.2 TYPICAL METAL STUD ANCHORAGE DETAIL 16 DETAIL ID: CS-STUD-21 NO. REMARKS DATE 60% COMPLETE SET 05/28/24 90% COMPLETE SET 07/12/24 ISSUE FOR BID 07/16/24 CITY SUBMITTAL 07/23/24 3009 S Daimler St 11/18/2024 3/8" DIA EXP ANCHOR W/ 2" MIN EMBED ELEVATION SINGLE JAMB TO BOTTOM TRACK PLAN VIEW JAMB PER SCHEDULE BOTTOM TRACK 3/ 4 " 3/ 4 " DIST 3" MIN EDGE EQ EQ EDGE OF SLAB WHERE OCCURS BENT PL 14GAx3"x3" W/ (4)#12 SMS TO JAMB #10 SMS EACH SIDE 3/8" DIA EXP ANCHOR W/ 2" MIN EMBED ELEVATION DOUBLE JAMB TO BOTTOM TRACK PLAN VIEW WHERE OCCURS DOUBLE JAMB PER SCHEDULE BOTTOM TRACK BENT PL 14GAx3"x3" W/ (4)#12 SMS TO JAMB, TYP TYP 1 1/2" TYP 1 1/2" TYP 1 1/2" TYP 1 1/2" TYP 2" CUT JAMB TRACK FLANGES AT BOTTOM TRACK CONNECTION STAGGER SMS 3/8" DIA EXP ANCHOR W/ 2" MIN EMBED ELEVATION DOUBLE JAMB PER SCHEDULE BOTTOM TRACK BENT PL 14GAx6"x3" (LLH) W/ (4)#12 SMS TO JAMB 4" DOUBLE JAMB TO END OF ZETRACK PLAN VIEW WHERE OCCURS 1-1/2" x 1-1/2" x 20GA x STUD DEPTH MINUS 1". USE (2)#10 SMS EACH LEG SOLID BLOCK FIT SNUG IN EACH STUD BAY. MATCH WALL STUD SIZE AND GAUGE WHERE PIPING/CONDUITS OCCUR, PROVIDE 2"x 18GA STRAP EACH SIDE OF WALL. LAP MIN 12" WITH BLOCKING AT EACH END. USE (4)#10 SMS TO BLOCKING PIPE/CONDUIT WHERE OCCURS NOTE: THIS DETAIL OCCURS WITH DRYWALL INSTALLED ON ONE SIDE OF WALL. A B TRACK BLOCKING (SIZE AND GAGE TO MATCH STUD, TYP) TRACK BLOCKING INVERTED BEND SHOE IN OPPOSITE DIRECTION ON ADJACENT BLOCKING BEND SHOE ON TRACK BLOCKING MIN 1 1/2" WITH (2)#10 SMS EACH SIDDE PER STUD NOTE: THIS DETAIL OCCURS WITH DRYWALL INSTALLED ON ONE SIDE OF WALL. 16GA CLIP TO BE ATTACHED W/ (2)#10 SMS TO "CRC" & (2)#10 SMS TO STUD WHERE BRACING TERMINATES AT BUILT-UP JAMB OR POST, EXTEND "CRC INTO PUNCH-OUT. ATTACH "CRC" TO JAMB OR POST WITH 16GA CLIP W/ (4)#10 SMS AT PRE-PUNCHED HOLES TYP LATERAL BRACING SPLICE USE: (1) 12" LONG "CRC" INVERTED OVER CENTER OF SPLICE W/(3) #10 SMS ON EACH SIDE OF SPLICE NOTES: 1. SIMPSON "SUBH" BRIDGING CONNECTORS MAY BE USED AS ALTERNATES TO 16GA CLIPS AT STUDS. 16GA "CRC" (COLD ROLLED CHANNEL) TO BE SPACED PER TYPICAL JAMB CORNER OR WALL INTERSECTON 3 STUDS AT INTERSECTIONS SAME SIZE AS ADJACENT STUDS INTERSECTION CORNER SMS @16" OC, (TYP) STUDS PIPE OR CONDUIT ANCHORS PER TYPICAL WALL CONSTRUCTION DETAIL BOTTOM TRACK TYP 6" MAX ADDED ANCHORS EACH SIDE (TYP) SPLICE LOCATION WHERE OCCURS ELEVATION W NOTCH OR SPLICE PIPE OR CONDUIT PENETRATION MAX 6" PLAN 3" MAX 2" MIN JAMB STUD A A .ADDED ANCHORS WHERE HOLE DIA IS GREATER THAN W/3 (2)#10 SMS @ 12" OC TYP (4" FROM ENDS) AWALL PERENDICULAR SUB PURLINS NOTES: 1. NO CONNECTIONS OF ARCHITECTURAL FINESHES TO TOP TRACK. 2. DO NOT CONNECT STUDS TO TOP TRACK. 3. SEE TYPICAL WALL STUD DETAIL FOR REMAINDER OF INFORMATION. B TYPICAL BRIDGING PL 14 GA x 4 x 1'-2" MIN @ 16" OC w/ # 12 SMS (TYP) TYPICAL STUDS PER WALL ARCH WALL PARALLEL TO SUB PURLINS NESTED SLIP TRACK PER . (3)#10 SMS @ 12" OC TYP (4" FROM ENDS) BLOCK BOTH SIDES WHERE WALL OCCUR DIRECTLY UNDER EXISTING SUB PURLIN (3)#10 SMS OR SELF TAPPING SHEET METAL SCREWS @ EACH STUD 362S162-54 STUDS @16" OC MAX BACK-TO BACK 362S162-54 STUD @16" OC MAX 600S162-54. DO NOT CUT FLANGES BETWEEN SUPPORTING STUDS (MIN LENGTH OF 3 BAYS) CUT T&B FLANGES OF TRACK AT EACH STUD (TYP) TYPICAL CONDITION } } FOR MAX UP/DOWN LOAD = 200# PLF FOR MAX UP/DOWN LOAD = 400# PLF (3)#10 SMS@ EACH STUD 362S162-54 STUDS @16" OC MAX LIGHT EQUIPMENT CONDITION 6" (MIN) x 54 MIL CONT PLATE (MIN LENGTH OF 3 BAYS) (USE FOR ITEMS WITH WEIGHT UP TO 20#) PLAN DETAIL A EXTEND BACKING ONE STUD BAY BEYOND EDGE OF ATTACHEMENT ON EACH SIDE NO PENETRATION IN BACKING WHERE ATTACHMENT OCCURS NOTES: BACKING CONT AT ALL CABINETS, SHELVING, TRACKBOARDS, CHALK-BOARDS, WALL AFFIXED EQUIPMENT, PLUS FURNISHINGS, TOILET FIXTURES, COUNTERS, DRINKING FOUNTAINS, ETC. (MIN LENGTH OF 3 BAYS) EQUIPMENT 'L' 'H' 16GA DEEP LEG TRACK #8 SMS EA SIDE 4"x20 GA CH STUD *. FULL HT WALL OR HANGING WALL WALL PERPENDICULAR TO SUB PURLINS 16GA LEG TRACK #8 SMS EA SIDE 4"x20 GA CH STUD *. WALL PARALLEL TO SUB PURLINS 31/32"45/64" *PROVIDE DIAG BRACE WHERE HANGING WALL OR NON FULL HT WALL OCCURS SEE TYP (3)#10 SMS @ 12" OC TYP (4" FROM ENDS) BLOCK BOTH SIDES WHERE WALL OCCUR DIRECTLY UNDER EXISTING SUB PURLIN (2)#10 SMS @ 12" OC TYP (4" FROM ENDS) "H" 1 1/2"x 1 1/2"x 16 GA ANGLE W/ #10 SMS EACH LEG TO FRAMING TYP 1 1/2"x 1 1/2"x 16 GA ANGLE W/ #10 SMS EACH STUD/JOIST AT OUTSIDE CORNERS OF OVERLAPPED FRAMING TYP 24" MAX WHERE COVE LIGHT CONDITION OCCURS PER ARCH EXTEND HORIZ STUD AS SHOWN TYP ALL CASES THIS DETAIL PROVIDE 4x BLOCKING OMIT HORIZONTAL STUD WHERE DROP CEILING OCCURS BOTH SIDE OMIT HORIZONTAL STUD WHERE DROP CEILING OCCURS BOTH SIDE CELING WHERE OCCURS PER ARCH CELING WHERE OCCURS PER ARCH 12 S1.3 (4)#8Øx1 1/2" WOOD SCREWS METAL STUD BRACE PERPENDICUALAR TO SUB PURLIN PARALLEL TO SUB PURLIN SIMPSON A35 EACH SIDE W/ #6x1/2" PAN HEAD SCREWS TO PLYWOOD (E) SUB PURLIN 4x BLKG W/SIMPSON FACEMOUNT HANGER EACH END (E) SUB PURLIN (E) SHEATHING (4)#8Øx1 1/2" WOOD SCREWS METAL STUD BRACE (E) SHEATHING No. 6250 FFOHSIB RYAN W. REGISTEREDPROFESSIONALENGINEER STRUCTURALSTATEOFCALIFORNIA DATE: FOR BRANDOW & JOHNSTON STRUCTURAL+CIVIL ENGINEERS (B&J HBK, INC.) 3300 IRVINE AVE. SUITE 245 NEWPORT BEACH, CALIFORNIA 92660 T:(949)862-8500 WWW.BJSCE.COM JOB#: 1 7 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 a r c h i t e c t u r e i n t e r i o r d e s i g n p l a n n i n g DA I M L E R A C P L 30 0 9 D A I M L E R S T SA N T A A N A , C A 9 2 7 9 5 S1.3 STEEL STUD DETAILS 07/23/24 SCALE: 1 1/2" = 1'-0"S1.3 TYPICAL JAMB CONNECTION 4 DETAIL ID: CS-MISC-04 SCALE: 1 1/2" = 1'-0"S1.3 STUD BLOCKING DETAIL 2 DETAIL ID: CS-STUD-12A SCALE: 1 1/2" = 1'-0"S1.3 TYPICAL CONTINUOUS WALL BRIDGING (DRYWALL ONE SIDE)10 DETAIL ID: CS-STUD-13 SCALE: 1 1/2" = 1'-0"S1.3 TYPICAL CORNERS AND INTERSCTIONS 5 DETAIL ID: CS-STUD-07 SCALE: 1" = 1'-0"S1.3 TYPICAL BOTTOM TRACK CONSTRUCTION 1 DETAIL ID: CS-STUD-08 SCALE: 1" = 1'-0"S1.3 TYPICAL INTERIOR METAL STUD TO DECK CONNECTION 9 DETAIL ID: CS-STUD-10 SCALE: 1 1/2" = 1'-0"S1.3 TYPICAL EQUIPMENT BACKING 14 DETAIL ID: CS-STUD-11 SCALE: 1" = 1'-0"S1.3 TYPICAL HANGING SOFFIT DETAILS 11 DETAIL ID: CS-XSTUD-14 NO. REMARKS DATE 60% COMPLETE SET 05/28/24 90% COMPLETE SET 07/12/24 ISSUE FOR BID 07/16/24 CITY SUBMITTAL 07/23/24 SCALE: 1" = 1'-0"S1.3 METAL STUD BRACING CONNECTION DETAIL 12 3009 S Daimler St 11/18/2024 LAG BOLT LEAD HOLE D (DIA) LEAD HOLE Ds (DIA)Dt (DIA) 1/2" 1/2"5/16" 5/8" 5/8"7/16" 3/4" 3/4" 1/2" NOTES: 1. ALL LAG BOLTS SHALL BE INSTALLED IN PRE-DRILLED LEAD HOLE. 2. LAG BOLTS SHALL BE TURNED BY A HAND WRENCH OR BY A POWER TORQUE WRENCH. 3. LAG BOLTS SHALL NOT BE HAMMERED!! 4. WHERE FULL THREADED BOLTS ARE INDICATED PROVIDE LEAD HOLE FOR DIAM. "Dt" FOR FULL DEPTH. 5. PROVIDE WASHER UNDER HEAD FOR BOLT HEAD IN CONTACT WITH WOOD. D LAG BOLT LENGTH LENGTH THREAD LENGTH SHANK LENGTH SHANK LENGTH THREAD LAG BOLT LENGTH (SHANK DIA) Ds (THREAD DIA) Dt MAX 24" 2X4 WITH SIMPSON "ZEE" CLIPS EA END EDGE NAIL ALL AROUND NOTE: FOR LARGER OPENINGS SEE DETAIL 7 S1.4 4x8 DF#1 SIMPSON CMST16 2 BAYS MIN EA SIDE 4x BLK 4x BLK4x BLK4x BLK PROVIDE 8d@4" OC, AROUND OPENING ALL SIDES (E ) S U B -PU R L I N S @ 2 4 " O C T Y P 4x BLK 4x BLK4x BLK4x BLK 4x8 DF#1 48" SQ MECHANICAL OPENING (E)ROOF JOIST PROVIDE SIMPSON 'U' HANGER TYP EA END CUT AND RE-SUPPORT (E)SUB-PURLIN W/ SIMPSON 'U' HANGER (TYP) LOCATE NEW MEMBER SO THAT IS DOESNT INTERFERE WITH (E)SUB-PURLIN OR HANGER 4x 8 D F # 1 4x 8 D F # 1 2x6 DF#1 SIMPSON CMST16 2 BAYS MIN EA SIDE 4x BLK PROVIDE 8d@4" OC, AROUND OPENING ALL SIDES (E ) S U B -PU R L I N S @ 2 4 " O C T Y P 4x BLK4x BLK24" SQ MECHANICAL OPENING MAX (E)ROOF JOIST PROVIDE SIMPSON 'U' HANGER TYP EA END CUT AND RE-SUPPORT (E)SUB-PURLIN W/ SIMPSON 'U' HANGER (TYP) LOCATE NEW MEMBER SO THAT IS DOESNT INTERFERE WITH (E)SUB-PURLIN OR HANGER 4x 6 D F # 1 4x 6 D F # 1 2x6 DF#1 (2)2x4 PROVIDE 8d@4" OC, AROUND OPENING ALL SIDES (E ) S U B -PU R L I N S @ 2 4 " O C T Y P 21 1/2" SQ MECHANICAL OPENING MAX (E)ROOF JOIST PROVIDE SIMPSON 'U' HANGER TYP EA END LOCATE NEW MEMBER SO THAT IS DOESNT INTERFERE WITH (E)SUB-PURLIN OR HANGER SI S T E R ( N ) 2 x 4 T O ( E ) 2 x 4 S U B - P U R L I N (E)ROOF JOIST 4x BLK 4x BLK 4x BLK (E)ROOF JOIST SI S T E R ( N ) 2 x 4 T O ( E ) 2 x 4 S U B - P U R L I N (2)2x4 CONDITION A 48" SQ CONDITION B 24" SQ CONDITION A 21 1/2" SQ W1 2 x 1 4 4x6 2x6@16" OC 4x6 4x6 4x6 4x 6 4x6 NOTES: 1. DO NOT DAMAGE (E)JOIST 2. ALL CONNECTIONS USE SIMPSON "LUS" OR "JS" HANGER UNO 3. PROVIDE 4x AT ALL ANCHOR LOCATIONS MECH EQUIP PER MECH DWG EXTENT OF UNIT SIMPSON MSTA 18 EA CORNER SUPPLY AND RETURN OPENING PER MECH SH A P E D # 1 4 x ( 9 1 / 4 " N E T M I N ) SH A P E D # 1 4 x ( 9 1 / 4 " N E T M I N ) PLAN VIEW 4 S1.4 MECH UNIT PLATFORM FRAMING METAL CURB W/ 1/2" DIA x 3" LONG LAG BOLTS PER MFR LAYOUT (4 MIN TOTAL) (E)ROOF SHEATHING (E)PURLIN PER PLAN 3/4" APA SHEATHING W/ 10d@6" OC EN AND 10d@12" OC FN SIMPSON BC40 HALF BASE AT 2' - 0" OC & WITHIN 6" EACH END (3 MIN EACH SIDE) EACH LONGITUDINAL SIDE W/ #10 x 3" SIMPSON SDS SCREWS BEAM PER PLAN (4x8 MIN UNO) CONNECTION PER . 4x BEAM (RIPPED FOR LEVELING) AT EDGE OF PLATFORM BEAM PER PLAN (4x8 MIN UNO) CONNECTION PER14 S1.4 14 S1.4 STRENGTHENED (E) PURLIN WHERE OCCURS PER PLAN AND .13 S1.4 10 S1.4 1 1/2" 1 1/2" 4" SIMPSON SDWS @12"OC STAGGERED EACH SIDE 3x14 DF#1 EACH SDIE PROVIDE FULL BEARING @ (E) SUB PURLINS (E) PURLIN (E) SUB PURLIN (E) SHEATHING 4x2'-0" BLKG EACH END W/ (2)-6" SIMPSON SDWS MINNOTE: 1. CONTRACTOR TO INSTALL REINFORCING PRIOR TO INSTALLATION OF MECHANICAL UNIT 2. CONTRACTOR TO SCHEDULE MEETING WITH SEOR TP REVIEW PLACEMENT OF BEAMS AND OBSTRUCTIONS IN PLACE AND DEVELOP A PLAN FOR REMOVAL AND REPLACEMENT OF OBSTRUCTIONS AS REQUIRED TO INSTALL FULL LENGTH REINFORCING 1 3/4"x 11 7/8" LVL EACH SIDE W/ SIMPSON HGU HANGER EACH END A B FACE MOUNTED HANGER TOP FLANGE HANGER (E) FRAMING OR BEAM PER PLAN (E) FRAMING OR BEAM PER PLAN BEAM PER PLAN W/ SIMPSON U HANGER TYP DRILL 1"Ø HOLE @ INSIDE CORNER. DO NOT OVERCUT BEAM PER PLAN W/ SIMPSON TOP FLANGE HANGER TYP NOTCH TOP CORNER OF 2x TO SET HANGER TYP 1/2"Ø LAG SCREWS W/ 4" EMBED 2" WIDE x 3/16" BENT PLATE (GALV & PAINTED) (E) ROOF PURLIN OR GLB (E) SHEATHING (E) ROOFING WATERPROOFING PENETRATION @ ROOF OR NEW FRAMING PER PLAN S1.4 11 7'-0" MAX SUPPORT PLATE (12 GA MIN) ATTACHED TO STACK 1/2"Ø WIRE P/T STRAND W/ CLAMP EACH END MIN. CAPCITY = 2500 LBS (MIN 3 DIRECTIONS @ 120° TYP) SPLAY WIRES TO AVOID ADJACENT WALKWAYS AND ROOFTOP EQUIPMENT TURNBUCKLE TYP EQUIPMENT PAD PER 4 S1.4 S1.4 7 FRAMED OPNG (E) SUB PURLINS/ RAFTER (E) PURLINS/GLB 1 2 MAX OR NEW FRAMING PER PLAN (E)SUB PURLIN 4x BLKG W/ SIMPSON LTP4 EA SIDE (E)ROOF SHEATHING BEAM PER PLAN No. 6250 FFOHSIB RYAN W. REGISTEREDPROFESSIONALENGINEER STRUCTURALSTATEOFCALIFORNIA DATE: FOR BRANDOW & JOHNSTON STRUCTURAL+CIVIL ENGINEERS (B&J HBK, INC.) 3300 IRVINE AVE. SUITE 245 NEWPORT BEACH, CALIFORNIA 92660 T:(949)862-8500 WWW.BJSCE.COM JOB#: 1 7 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 a r c h i t e c t u r e i n t e r i o r d e s i g n p l a n n i n g DA I M L E R A C P L 30 0 9 D A I M L E R S T SA N T A A N A , C A 9 2 7 9 5 S1.4 DETAILS 07/23/24 SCALE: 3" = 1'-0"S1.4 TYPICAL WOOD DETAIL 1 DETAIL ID: WOOD-MISC-10 SCALE: 1 1/2" = 1'-0"S1.4 TYPICAL SMALL ROOF OPENING DETAIL 2 DETAIL ID: WOOD-SWLR-02 SCALE: 1/2" = 1'-0"S1.4 TYPICAL PANAELIZED OPEN FOR MECHANICAL EQUIPMENT 7 DETAIL ID: EXS-OPEN-02 SCALE: 1/2" = 1'-0"S1.4 TYPICAL EQUIPMENT SUPPORT FRAMING 10 DETAIL ID: EXS-MECH-01 SCALE: 3/4" = 1'-0"S1.4 TYPICAL EQUIPMENT SUPPORT FRAMING 4 DETAIL ID: EXS-MECH-01C SCALE: 1" = 1'-0"S1.4 PURLIN STRENGTHENING DETAIL 13 SCALE: 1" = 1'-0"S1.4 TYPICAL JOIST TO BEAM DETAIL 14 SCALE: 1" = 1'-0"S1.4 WIRE SUPPORT AT CHIMMENY DETAIL 11 SCALE: 1" = 1'-0"S1.4 WIRE SUPPORT AT CHIMMENY DETAIL 16 SCALE: 1" = 1'-0"S1.4 TYPICAL (E) BEAM STRENGTHENING DETAIL 3 DETAIL ID: EXS-ROOF-02 NO. REMARKS DATE 60% COMPLETE SET 05/28/24 90% COMPLETE SET 07/12/24 ISSUE FOR BID 07/16/24 CITY SUBMITTAL 07/23/24 3009 S Daimler St 11/18/2024 9 S1.5 8 S1.5 7 S1.5 CONT UNISTRUT P1000 UNISTRUT P1001 @6'-0"OC 3'-0" MAX 1/2"Ø THREADED ROD UNISTRUT P1000 BRACE @6'-0"OC 1 1 CEILING PER ARCH BUSWAY/CABLE TRAY PER ELECTRICAL (100 PLF MAX) 3/8"Ø THREADED ROD W/ CHANNEL NUTS AND LOCKING WASHERS AT TRAY - --- L2 1/2x 2 1/2x 14 GA x0'-5" W/(3)-#10 SCREWS EACH LEG BOTH SIDE TYP (E) PURLIN NUT EACH SIDE OF FLANGE TOP *& BOTTOM TYP 1/2"Ø THREADED ROD 800# MAX NESTED METAL STUD JOIST - ---S1.5 7 1/2"Ø THRU BOLT UNISTRUT BRACE UNISTRUT P1843 TYP ABRACE ATTACHMENT TO (E) PURLIN P1000 W/BEAM CLAMP EACH SIDE UNISTRUT BRACE BBRACE ATTACHMENT TO (E) BEAM SUPPORT ROD UNISTRUT P2486 @12"OC UNISTRUT P1000 ROD STIFFENER 1 1/2"3 1/2"3 1/2"1 1/2" 2" 2" 4"x3"x1/4 PLATE EACH SIDE (3) 1/2"Ø HILTI KB-TZ2 SS W/ 3 1/4" EMBED HORIZ ANGLE(E) ROOF SHEATHING (E) PARAPET ANGLE POST 2" (E) WATERPROOFING 8" 1 1/2" 1 1/2" EQ EQ (E) BEAM PER PLAN (2) 3/4"Ø LAG SCREWS W/7" MIN EMBED NEW OR (E) PURLIN REINFORCING ROUND HSS PER & . 12 S1.5 16 S1.5 5/8" BASE PLATE 3 1/2". 4'-9". (E) SHEATHING BEAM PER PLAN EQ EQ PER ARCH 6'-0" MAX 8'-6" MAX ABOVE ROOF SHEATHING 2'-0" TYP 5/8"Ø A307 BOLT L4x4x1/4 BRACE @8'-0" MAX PER PLAN L4x4x1/4 TYP HORIZ WIND SCREEN PER ARCH L4x4x1/4 POST @8'-0"OC MAX PER PLAN 5/8"Ø A307 BOLT WT4x6.5 x0'-4" ROUND HSS3x 1/4 TYP BASE PLATE PER 13 S1.5 (E) BEAM PER PLAN (SEE NOTE) CL BEAM & POSTCL BEAM & POST WATERPROOFING PER ARCH 8" MAX 1/4 TYP T&B L4x4x1/4 AT EACH POST/BRACE NOTE: WHERE (E) BEAM IS NOT REINFORCED PROVIDE STRENGTHENING PER 13 S1.4 BEAM PER PLAN EQ EQ 6'-0" MAX 8'-6" MAX ABOVE ROOF SHEATHING 2'-0" TYP 5/8"Ø A307 BOLT L4x4x1/4 BRACE @8'-0" MAX PER PLAN L4x4x1/4 TYP HORIZ WIND SCREEN PER ARCH L4x4x1/4 POST @8'-0"OC MAX PER PLAN 5/8"Ø A307 BOLT EA END WT4x6.5 x0'-4" ROUND HSS3x 1/4 TYP BASE PLATE PER 13 S1.5 (E) BEAM PER PLAN (SEE NOTE 1) CL BEAM & POST 8" MAX3" 1/4 TYP T&B 5" 4" 1" TYP SEE NOTE 2 18" VIF NOTESl 1. WHERE (E) BEAM IS NOT REINFORCED PROVIDE STRENGTHENING PER 2. WHERE DIMENSIONS IS LESS THAN 18" PROVIDE CONNECTION TO PARAPET PER 3. FOR ADDITIONAL INFORMATION NOT SHOWN SEE 13 S1.4 14 S1.5 12 S1.5 1/2"Ø HILTI KB-TZ2 SS W/3 1/4" EMBED (E) WATERPROOFING VIF L4x4x1/4 AT EACH POST/BRACE No. 6250 FFOHSIB RYANW. REGISTEREDPROFESSIONALENGINEER STRUCTURALSTATEOFCALIFORNIA DATE: FOR BRANDOW & JOHNSTON STRUCTURAL+CIVIL ENGINEERS (B&J HBK, INC.) 3300 IRVINE AVE. SUITE 245 NEWPORT BEACH, CALIFORNIA 92660 T:(949)862-8500 WWW.BJSCE.COM JOB#: 1 7 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 a r c h i t e c t u r e i n t e r i o r d e s i g n p l a n n i n g DA I M L E R A C P L 30 0 9 D A I M L E R S T SA N T A A N A , C A 9 2 7 9 5 S1.5 DETAILS 09/25/24 SCALE: 1" = 1'-0"S1.5 EXISTING PAD 1 SCALE: 1" = 1'-0"S1.5 ELECTRICAL BUSWAY OUT OF PLANE BRACE DETAIL 4 SCALE: 1" = 1'-0"S1.5 HANGER ATTACHMENT TO (E) PURLIN 7 SCALE: 1" = 1'-0"S1.5 OUT OF PLANE BRACE ATTACHMENT 8 SCALE: 1 1/2" = 1'-0"S1.5 ROD STIFFENER DETAIL 9 NO. REMARKS DATE 60% COMPLETE SET 05/28/24 90% COMPLETE SET 07/12/24 ISSUE FOR BID 07/18/24 CITY SUBMITTAL 07/23/24 1 CITY RESUBMITTAL 09/24/24 SCALE: 3" = 1'-0"S1.5 WIND SCREEN DETAIL 14 SCALE: 3" = 1'-0"S1.5 WIND SCREEN BASE PLATE 13 SCALE: 1" = 1'-0"S1.5 WIND SCREEN SECTION 12 SCALE: 1" = 1'-0"S1.5 WIND SCREEN SECTION 16 1 1 1 1 3009 S Daimler St 11/18/2024 13 11 5 TA B L E 96 X 2 4 TA B L E 96 X 2 4 TABLE 96X24 90 TABLE 96"X30" TABLE 96"X30" TABLE 96"X30" TABLE 96"X30" TABLE 96"X30" TABLE 60X24 54 RACK 60"X24" TABLE 108"X24" RACK 60"X24" RACK 60"X24" TA B L E 72 " X 2 4 " TABLE 96X24 TABLE 108"X24" RACK 60"X24" RACK 60"X24" TABLE 96"X24" TABLE 96X24 TABLE 96X24 ST O R A G E 96 X 2 4 TABLE 96"X30" TABLE 96"X30" TABLE 96"X30" TABLE 96"X30" TABLE 96"X30" TABLE 96"X24" TABLE 96"X30" TABLE 96"X30" TABLE 96"X30" TABLE 96"X30" TABLE 96"X30" TABLE 96"X24" RACK 60"X24" RACK 60"X24" 99 81 37 TABLE 60"X30" TABLE 60"X30" TABLE 60"X30" TABLE 60"X30" TABLE 60"X30" TABLE 60"X30" 6910 46 21 22 23 25 38 39 40 41 42 43 48 48 55 85 86 87 8889 939496 97 53 65 84 TANK 83 112 113 114115 77 23 29 PORTABLE EYEWASH PORTABLE EYEWASH 27 CABINET 42"X24" PORTABLE EYEWASH 4949 W x 4 2 D x 6 4 H - 2 7 5 0 L B S ( C U - 3 2 0 0 ) FUTURE FUTURE FUTURE FUTURE FEC FEC (N) FEC (N) FEC (E) FEC (E) - STORAGE ENCLOSURE - HVAC ENCLOSURE - WATER PRODUCTION ROOM MICROBIOLOGY (IIM) EQL./IMM STORAGE GOWNING CLOSET - STERILITY SUITE - RISER RM. - CORRIDOR - CORRIDOR 176 EXTRUSION ROOM 1,434 SF 178 BRADING ROOM 607 SF 177 TOOL CLN. ROOM 171 SF 175 LAB 2,505 SF - LOADING DOCK 179 ELECTRICAL ROOM 130 SF 662 S.F. 590 S.F. 689 S.F. 37 S.F. 216 S.F. 53 S.F. CEILING HEIGHT 10'-0" B.O. CONDUIT: 18'-3" B.O. UNISTRUT: 10'-6" B.O. BOX: 10'-0" B.O. BOX: 11'-3" B.O. UNISTRUT: 16'-0" B.O. UNISTRUT: 16'-0" CEILING HEIGHT 10'-0" CEILING HEIGHT 11'-0" CEILING HEIGHT 11'-0" CEILING HEIGHT 11'-0" CEILING HEIGHT 11'-0" TA B L E 72 " X 2 4 " C.R. C.R. HM3 1L21 1L22 T500 DBL2 1 2 3 4 C D E (E) EXTERIOR ENCLOSURE (E) BUILDING COLUMN BENCHES AND EQUIPMENT PER ARCH LAYOUT TYPICAL SAWCUT AND SLAB REPAIR AS REQUIRED PER DETAILS ON SHEET S1.1 SEE PLUMBING DRAWINGS (E) CONCRETE WALL (E) SLAB ON GRADE 800# 800# 800# HD R H D R HD R HEADER / SOFFIT FRAMING ABOVE PER ARCH 11 S1.3 ELECTRICAL BUSWAYS PER ELECTRICAL DRAWINGS SEE SHEET S1.5 FOR ADDTIONAL INFORMATION ELECTRICAL BUSWAYS PER ELECTRICAL DRAWINGS SEE SHEET S1.5 FOR ADDTIONAL INFORMATION EQUIPMENT ON CASTERS AND LEVELING FEET TYP EQUIPMENT ON CASTERS AND LEVELING FEET TYP ANCHOR PER (E) CONCRETE WALL 13 S1.1 27 84 13 ANCHOR PER 13 S1.1 ANCHOR PER 13 S1.1 PLAN NOTES: 1. ALL EXISTING MEMBERS ARE BASED ON RECORD DRAWINGS CONTRACTOR SHALL NOTIFY ENGINEER IF CONDITIONS DISCOVERED DURING CONSTRUCTION VARYSIGNIFICANTLY FROM WHAT IS SHOWN ON PLANS 2. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND FINISHES NOT INDICATED ON THIS PLAN 3. INDICATES OPERATING WEIGHT OF UNIT SEE ANCHORAGE DETAIL ON VERIFY WITH OWNER AND MANUFACTURER - UNIT ON CASTERS, TABLE TOPS, OR OTHERWISE MOBILE ARE NOT REQUIRED TO BE ANCHORED 4. FOR TYPICAL METAL STUD DETAILS SEE SHEETS S1.2 & S1.3 COORDINATE WITH ARCH DRAWINGS 5. FOR ELECTRICAL, TRANSFORMER LOCATION AND SUPPORT SEE ELECTRICAL DRAWINGS AND ANCHORAGE TO SLAB WITH MINIMUM (4) 1/2"Ø HILTI KB-TZ2 ANCHORS W/2" EMBEDMENT IN MANUFACTURE HOLES 6. FOR TYPICAL SLAB ON GRADE REPAIR DETAIL AT MEP TRENCHES - SEE MEP DRAWINGS AND DETAIL ON 400# 13 S1.1 6 S1.1 No. 6250 FFOHSIB RYANW. REGISTEREDPROFESSIONALENGINEER STRUCTURALSTATEOFCALIFORNIA DATE: FOR BRANDOW & JOHNSTON STRUCTURAL+CIVIL ENGINEERS (B&J HBK, INC.) 3300 IRVINE AVE. SUITE 245 NEWPORT BEACH, CALIFORNIA 92660 T:(949)862-8500 WWW.BJSCE.COM JOB#: 1 7 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 a r c h i t e c t u r e i n t e r i o r d e s i g n p l a n n i n g DA I M L E R A C P L 30 0 9 D A I M L E R S T SA N T A A N A , C A 9 2 7 9 5 S2.1 FIRST FLOOR PLAN 09/25/24 (E) CONCRETE WALL NO. REMARKS DATE 60% COMPLETE SET 05/28/24 90% COMPLETE SET 07/12/24 ISSUE FOR BID 07/18/24 CITY SUBMITTAL 07/23/24 1 CITY RESUBMITTAL 09/24/24 1 1 3009 S Daimler St 11/18/2024 VFD 7 VFD 8 VFD 9 VFD 11 EF 11 VFD 10 EF 10 AC 10 AC 11 AC 12 AC 9 EF 7 EF 8 EF 9 EF 12 1 2 3 4 5 C D E 815# 600# 500# 350# (E) ROOF PLAD (E) ROOF PAD (E) ROOF PAD S1.4 7 TYP AT DUCT OPNG TYP 75#75#75# UNISTRUT SUPPORT RACK AT VFD PER MECH DETAIL ON M2.1 PROVIDE 4x6 BLKG BELOW ANCHOR POINTS AS REQ NEW ROOF PAD PER 10 S1.4 PROVIDE EF GUY WIRE SUPPORT AT STACK PER MECH AND 16 S1.4 NEW ROOF PAD PER 10 S1.4 NEW ROOF PAD PER 10 S1.4 75# 75# (E) WALKING PAD (E) EQUIPMENT VIF (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 ( E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 ( E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E ) 4 x 1 6 (E)5.125x31.5(E)5.125x31.5 (E)5.125x31.5 (E)5.125x31.5 (E)5.125x31.5(E)5.125x31.5 RE I N F O R C E ( E ) P U R L I N P E R N O T E 5 RE I N F O R C E ( E ) P U R L I N PE R N O T E 5 4x12 4x12 4x12 4x12 RE I N F O R C E ( E ) P U R L I N P E R N O T E 5 RE I N F O R C E ( E ) P U R L I N P E R N O T E 5 4x12 4x12 4x12 4x12 RE I N F O R C E ( E ) P U R L I N P E R N O T E 5 RE I N F O R C E ( E ) P U R L I N PE R N O T E 5 RE I N F O R C E ( E ) P U R L I N P E R N O T E 5 (E) CONCRETE WALL/PARAPET (E)2x4 SUB PURLINS TYP EF 7 EF 8 EF 9 (E) PLYWOOD ROOF SHEATHING EF 6 VFD 6 EF 5 VFD 5 RTU 9 RTU 12 RTU 11 RTU 10 VFD 1 VFD 2 VFD 3 4x12 4x12 4x12 4x12 4x 1 2 4x 1 2 4x 1 2 4x 1 2 EF 12 75# 4x10 4x10 4x10 4x10 4x10 4x10 4x104x104x104x104x10 12 S1.5 16 S1.5 TYP @ PARAPET WIND SCREEN PER ARCH WIND SCREEN PER ARCH 12 S1.5 SHIFT DUCT SLIGHTLY AS REQ TO AVOID MAJOR ROOF MEMBERS VERIFY IN FIELD PLAN NOTES: 1. ALL EXISTING MEMBERS ARE BASED ON RECORD DRAWINGS CONTRACTOR SHALL NOTIFY ENGINEER IF CONDITIONS DISCOVERED DURING CONSTRUCTION VARYSIGNIFICANTLY FROM WHAT IS SHOWN ON PLANS 2. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND FINISHES NOT INDICATED ON THIS PLAN 3. INDICATES OPERATING WEIGHT OF UNIT SEE ANCHORAGE DETAIL ON 4. CONTRACTOR TO VERIFY EXISTING PLATFORM CONSTRUCTION AND PROVIDE MINIMUM ANCHORAGE PER NEW PLATFORM DETAIL. SEE FOR REFERENCE ONLY EXISTING RECORD DETAIL OF EXISTING MECHANICAL UNITS ON FOR MORE INFORMATION 5. VERIFIY EXISTING REINFORCED MEMBERS AS SHOWN WITH INSTALL NEW REINFORCING AT MEMBERS SHOWN WITH OR EXISTING MEMBERS MISSING REINFORCING SHOWN PER DETAIL 6. INDICATES ANGLE BRACE PER OR 400# 10 S1.4 1 S1.5 13 S1.4 12 S1.5 16 S1.5 No. 6250 FFOHSIB RYANW. REGISTEREDPROFESSIONALENGINEER STRUCTURALSTATEOFCALIFORNIA DATE: FOR BRANDOW & JOHNSTON STRUCTURAL+CIVIL ENGINEERS (B&J HBK, INC.) 3300 IRVINE AVE. SUITE 245 NEWPORT BEACH, CALIFORNIA 92660 T:(949)862-8500 WWW.BJSCE.COM JOB#: 1 7 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 a r c h i t e c t u r e i n t e r i o r d e s i g n p l a n n i n g DA I M L E R A C P L 30 0 9 D A I M L E R S T SA N T A A N A , C A 9 2 7 9 5 S2.2 ROOF PLAN 09/25/24 NO. REMARKS DATE 60% COMPLETE SET 05/28/24 90% COMPLETE SET 07/12/24 ISSUE FOR BID 07/18/24 CITY SUBMITTAL 07/23/24 1 CITY RESUBMITTAL 09/24/24 1 1 1 6" 6" 3009 S Daimler St 11/18/2024 ABBREVIATIONS +48"HEIGHT TO CENTERLINE OF DEVICE OR BOTTOM OF LIGHT FIXTURE (D)EXISTING TO BE DEMOLISH (E)EXISTING TO REMAIN (ER)EXISTING TO BE RELOCATED (N)NEW (R)RELOCATED AC AIR CONDITIONING UNIT ACC AIR COOLED CONDENSER AFC AVAILABLE FAULT CURRENT AFD ADAPTIVE FREQUENCY DRIVE AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AFS ABOVE FINISHED SLAB AH, AHU AIR HANDLER, AIR HANDLER UNIT AIC AMPS INTERRUPTING CAPACITY AF CIRCUIT BREAKER FRAME RATING OR DISCONNECT SWITCH FUSE RATING ALSIG ARC REDUCTION, LONG TIME, SHORT TIME, INSTANTANEOUS, GROUND FAULT TRIP AS DISCONNECT SWITCH AMP RATING AT CIRCUIT BREAKER TRIP RATING AMP, AMPS AMPERE, AMPERES ARCH ARCHITECT AWG AMERICAN WIRE GUAGE BCM BRANCH CIRCUIT MONITOR SYSTEM BIL BASIC INSULATION LEVEL CEC CALIFORNIA ELECTRICAL CODE, CURRENT EDITION C CONDUIT CAP CAPACITOR CB CIRCUIT BREAKER OR CONTROL BOX CBC CALIFORNIA BUILDING CODE, CURRENT EDITION CFC CALIFORNIA FIRE CODE, CURRENT EDITION CL CONTINUOUS LOAD CLG CEILING CO CONDUIT ONLY WITH NYLON PULL LINE, CAP AND MARK CRAC COMPUTER ROOM AIR CONDITIONER CU CONDENSING UNIT DB DISTRIBUTION BOARD DF, EDF DRINKING FOUNTAIN DSD DUCT SMOKE DETECTOR EC ELECTRICAL CONTRACTOR EF EXHAUST FAN EG, G EQUIPMENT GROUND EM EMERGECY LIGHT FIXTURE WITH UL 924 LISTED 90 MINUTE BACKUP POWER SOURCE EPO EMERGENCY POWER OFF ESS, BESS ENERGY STORAGE SYSTEM, BATTERY ENERGY STORAGE SYSTEM EVSE ELECTRIC VEHICLE SUPPLY EQUIPMENT (AKA "ELECTRIC VEHICLE CHARGER") FC FAN COIL FBO FURNISHED BY OTHERS FV FIELD VERIFY H HOT, PHASE CONDUCTOR HP HORSEPOWER OR HEAT PUMP HCB HVLS CONTROL BOX WITH INTEGRAL DISCONNECT HVLS HIGH VOLUME LOW SPEED CEILING FAN HZ HERTZ IDF INTERMEDIATE DISTRIBUTION FRAME GC GENERAL CONTRACTOR GF, GFI, GFCI GROUND FAULT CIRCUIT INTERRUPTER GFPE GROUND FAULT PROTECTION FOR EQUIPMENT G, GND GROUND GB GROUND BUS IAW IN ACCORDANCE WITH IG, ISO ISOLATED GROUND KA KILOAMPERES KV KILOVOLTS KVA KILOVOLT AMPERES KVAR KILOVOLT AMPERES REACTIVE KW KILOWATTS LCP LIGHTING CONTROL PANEL LIS LOAD INTERRUPTER SWITCH LT, LTS LIGHT, LIGHTS LTG LIGHTING LO/TO LOCK OUT / TAG OUT PER BUILDING OR OWNER STANDARDS MBP MAINTENANCE BYPASS MC MECHANICAL CONTRACTOR MDF MAIN DISTRIBUTION FRAME ME MECHANICAL OR PLUMBING ENGINEER MGB MAIN GROUND BUS MHE MATERIAL HANDLING EQUIPMENT MTD MOUNTED MTBB MAIN TELEPHONE BACKBOARD MV MEDIUM VOLTAGE N NEUTRAL, GROUNDED CONDUCTOR NL NIGHT LIGHT, ON AT DUSK AND OFF AT DAWN NTS NOT TO SCALE OFCI OWNER FURNISHED, CONTRACTOR INSTALLED P PUMP PC PLUMBING CONTRACTOR PE PROFESSIONAL ENGINEER PB PULL BOX PH PHASE PNL PANEL PV PHOTOVOLTAIC REC, RECEPT RECEPTACLE(S) SE STRUCTURAL ENGINEER SF SQUARE FEET OR SUPPLY FAN SFD SMOKE FIRE DAMPER SLD SINGLE LINE DIAGRAM SWBD SWITCHBOARD SWGR SWITCHGEAR TBB TELEPHONE BACKBOARD TITLE 24, T24 CALIFORNIA ENERGY CODE (TITLE 24 PART 6) TR TRUCK RESTRAINT TYP TYPICAL UG UNDERGROUND UGPS UNDERGROUND PULL SECTION UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY VA VOLT-AMPS VD VOLTAGE DROP VFD VARIABLE FREQUENCY DRIVE VIF VERIFY IN FIELD VL VERIFY LOCATION W WATTS WHS WAREHOUSE WP WEATHERPROOF OR NEMA 3R AS APPLICABLE XFMR, T TRANSFORMER [XXX]INDICATES MANUFACTURES CIRCUIT BREAKER TYPE PART 1 - GENERAL 1.CODE IN EFFECT: 2022 CALIFORNIA ELECTRICAL CODE, HEREAFTER REFERRED TO AS "CODE." 2."PROVIDE" INDICATES ITEM FURNISHED, INSTALLED AND CONNECTED. 3.THE SPECIFICATIONS AND DRAWINGS ARE INTENDED TO COVER A COMPLETE INSTALLATION OF SYSTEMS. THE OMISSION OF EXPRESSED REFERENCE TO ANY ITEM OF LABOR OR MATERIAL FOR THE PROPER EXECUTION OF THE WORK IN ACCORDANCE WITH PRESENT PRACTICE OF THE TRADE SHALL NOT RELIEVE THE CONTRACTOR FROM PROVIDING SUCH ADDITIONAL LABOR AND MATERIALS. UNLESS OTHERWISE NOTED, THESE SPECIFICATIONS AND NOTES APPLY TO THE SCOPE OF THESE CONSTRUCTION DOCUMENTS ONLY. 4.ALL NEW WORK AND MATERIALS IN THE SCOPE OF WORK SHALL BE IN FULL COMPLIANCE WITH THE LATEST AND MOST STRINGENT APPLICABLE CODE OR REGULATION. CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR ANY ADDITIONAL COSTS FOR MATERIALS OR LABOR TO COMPLY WITH THESE CODES OR REGULATIONS. 5.NOTHING ON THE DESIGN DRAWINGS SHALL BE DEEMED AS PERMISSION TO VIOLATE THE LATEST AND MOST STRINGENT APPLICABLE CODE OR REGULATION. 6.THE CONTRACTOR SHALL VISIT THE SITE, VERIFY THE EXACT CONDITIONS RELATING TO THE WORK AND SHALL OBTAIN SUCH INFORMATION AS MAY BE NECESSARY TO PRESENT A CONCLUSIVE BID. NO ALLOWANCES SHALL BE MADE FOR ANY EXTRA EXPENSE, DUE TO FAILURE OF THE CONTRACTOR TO MAKE SUCH A FIELD VERIFICATION. BY SUBMITTING A PROPOSAL FOR THE WORK INCLUDED IN THE CONTRACT. THE CONTRACTOR SHALL BE DEEMED TO HAVE MADE THE FIELD VERIFICATION AND ACCEPTS ALL JOB SITE CONDITIONS. 7.REFER TO THE DRAWINGS AND SHOP DRAWINGS OF OTHER TRADES FOR ADDITIONAL DETAILS WHICH AFFECT THE PROPER INSTALLATION OF THIS WORK. DIAGRAMS AND SYMBOLS SHOWING ELECTRICAL CONNECTIONS ARE DIAGRAMMATIC ONLY. WIRING DIAGRAMS DO NOT NECESSARILY SHOW THE EXACT PHYSICAL ARRANGEMENT OF THE EQUIPMENT. 8.THE DRAWINGS INDICATE DIAGRAMMATICALLY THE DESIRED LOCATIONS OR ARRANGEMENTS OF CONDUIT RUNS, OUTLETS, EQUIPMENT, ETC., AND ARE TO BE FOLLOWED AS CLOSELY AS POSSIBLE. PROPER JUDGMENT MUST BE EXERCISED IN EXECUTING THE WORK SO AS TO SECURE THE BEST POSSIBLE INSTALLATION IN THE AVAILABLE SPACE AND TO OVERCOME LOCAL DIFFICULTIES DUE TO SPACE LIMITATIONS OR INTERFERENCE OF STRUCTURE CONDITIONS ENCOUNTERED. ALL EQUIPMENT SHALL BE LOCATED SUCH THAT CODE REQUIRED CLEARANCES ARE MAINTAINED. 9.IF THERE ARE OMISSIONS OR CONFLICTS BETWEEN THE DRAWINGS AND SPECIFICATIONS, CLARIFY THESE POINTS, IN WRITING, WITH THE ARCHITECT BEFORE SUBMITTING BID. 10.USE ONLY COMPETENT SKILLED PERSONNEL. PERFORM ALL WORK CONSISTENT WITH THE BEST POSSIBLE TRADE PRACTICES. 11.CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, INSURANCE, EQUIPMENT, INSTALLATION, CONSTRUCTION TOOLS, TRANSPORTATION, ETC. FOR A COMPLETE AND PROPERLY OPERATING ELECTRICAL SYSTEM. 12.ALL MATERIALS SHALL BE NEW AND OF THE SAME MANUFACTURER FOR EACH CLASS OR GROUP OF EQUIPMENT. MATERIALS SHALL BE LISTED AND LABELED BY UNDERWRITER'S LABORATORIES, AND SHALL BEAR THE INSPECTION LABEL WHERE SUBJECT TO SUCH APPROVAL. MATERIALS SHALL MEET WITH THE APPROVAL OF THE DIVISION OF INDUSTRIAL SAFETY, AND ALL GOVERNING BODIES HAVING JURISDICTION. MATERIALS SHALL BE MANUFACTURED IN ACCORDANCE WITH APPLICABLE STANDARDS ESTABLISHED BY A.N.S.I., U.L., N.E.M.A. AND N.B.F.U. INSTALL PER MANUFACTURERS' RECOMMENDATIONS. IF APPLICABLE, ALL EQUIPMENT SHALL BE APPROVED AND LISTED FOR USE IN THIS CITY. 13.SWITCHBOARDS, PANELBOARDS, TERMINAL CABINETS, CIRCUIT BREAKERS, DISCONNECT SWITCHES, STARTERS RELAYS, TIME SWITCHES, CONTACTORS, PUSH-BUTTON CONTROL STATIONS, AND OTHER APPARATUS USED FOR THE OPERATION OR CONTROL OF FEEDERS, CIRCUITS, APPLIANCES, OR EQUIPMENT SHALL BE PROPERLY IDENTIFIED BY MEANS OF DESCRIPTIVE NAMEPLATES OR TAGS PERMANENTLY ATTACHED TO THE APPARATUS AND WIRING. 14.CONTRACTOR SHALL SECURE AND PAY FOR ALL NECESSARY BUILDING PERMITS AND FEES. COORDINATE TEMPORARY CONSTRUCTION REQUIREMENTS WITH ALL TRADES PRIOR TO CONSTRUCTION. INCLUDE ALL COSTS IN THE BID. 15.THE CONTRACTOR SHALL OBTAIN AN INDEPENDENT TESTING LABORATORY THAT WILL PROVIDE ALL INSTRUMENTATION AND TESTS ON THE ELECTRICAL SYSTEM AND EQUIPMENT AS HEREINAFTER DESCRIBED AND FURTHER DIRECTED BY THE ARCHITECT. THE TEST SHALL BE PERFORMED AFTER THE COMPLETION OF ALL ELECTRICAL SYSTEMS COVERED UNDER THIS SECTION OF THE SPECIFICATIONS. ALL TESTS SHALL BE RECORDED, DOCUMENTED AND SUBMITTED TO THE ENGINEER FOR REVIEW. COST OF ALL TESTING SHALL BE BORNE BY THE CONTRACTOR. 16.THE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF ACCEPTANCE BY OWNER. ANY WORK, MATERIAL OR EQUIPMENT FOUND TO BE FAULTY DURING THAT PERIOD SHALL BE CORRECTED AT ONCE, UPON WRITTEN NOTIFICATION AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. 17.WHERE A CONFLICT OCCURS BETWEEN THIS SPECIFICATION AND OTHER SPECIFICATIONS ISSUED AS A PART OF THE CONTRACT DOCUMENTS, THE MORE STRINGENT REQUIREMENTS SHALL PREVAIL. 18.ALL ADDENDA AND CHANGE ORDERS SHALL BE APPROVED BY OWNER. 19.CONTRACTOR SHALL SUBMIT 1 COPY OF SHOP DRAWINGS, IN PDF FORMAT, FOR ALL MAJOR PIECES OF ELECTRICAL EQUIPMENT, INCLUDING, BUT NOT LIMITED TO SWITCHBOARDS, PANELBOARDS, TRANSFORMERS, MOTION SENSORS AND ALL LIGHTING FIXTURES. SUBMITTALS SHALL BE MADE TO THE ARCHITECT AS SOON AS IS PRACTICABLE AFTER AWARD OF CONTRACT. CONTRACTOR SHALL NOT ORDER EQUIPMENT UNTIL SUBMITTALS HAVE BEEN RETURNED AND STAMPED "REVIEWED" OR "REVIEWED AND CORRECTED" BY THIS OFFICE. MINIMUM REVIEW TIME IS TWO WEEKS UNLESS SUBSTITUTES HAVE BEEN SUBMITTED, WHICH MAY RESULT IN SIGNIFICANTLY LONGER REVIEW TIME. IN THE EVENT THE CONTRACTOR SUBMITS A SUBSTITUTION, HE SHALL IDENTIFY EACH PROPOSED SUBSTITUTION AND PROVIDE A DETAILED COMPARISON BETWEEN THE SPECIFICATION ITEM AND THE SUBSTITUTION. SIMPLY PROVIDING MANUFACTURES CUT SHEETS WILL NOT BE ACCEPTABLE. THE CONTRACTOR SHALL CONSIDER AND INCLUDE SUBMITTAL REVIEW TIME IN HIS TIMELINE. HOWEVER, NOTHING WITHIN THIS SECTION SHALL BE CONSTRUED AS A GUARANTEED REVIEW TIME. BY BIDDING THESE CONTRACT DOCUMENTS, THE CONTRACTOR AGREES TO HOLD THE OWNER AND ENTIRE DESIGN TEAM HARMLESS FOR ANY COSTS INCURRED AS A RESULT OF ANY SUBMITTAL REVIEW DELAY. 20.ALL BROCHURES, OPERATING MANUAL, CATALOGS, SHOP DRAWINGS, "AS-BUILTS", ETC. SHALL BE TURNED OVER TO THE OWNER AT THE COMPLETION OF THE JOB. PROVIDE THE OWNER WITH ONE (1) SET OF COMPLETE ELECTRICAL "AS-BUILT" DRAWINGS INDICATING FINAL EQUIPMENT/DEVICE LOCATIONS, CONDUIT ROUTING, ETC. ALL DEVIATIONS FROM ELECTRICAL DESIGN SHALL BE DOCUMENTED AND SUBMITTED TO ARCHITECT. 21.WHERE IT IS NECESSARY TO SHUT OFF UTILITY SERVICES OR CAUSE ANY POWER OR SIGNAL INTERRUPTIONS WHILE THE BUILDING IS OCCUPIED, SCHEDULE ALL OUTAGES OR INTERRUPTIONS WITH THE OCCUPANTS OF THE BUILDING OR AS DIRECTED BY THE OWNER. ALL SUCH OUTAGES OR INTERRUPTIONS SHALL BE INCLUDED IN BID AND SCHEDULED AT THE CONVENIENCE OF THE OCCUPANTS. 22.WHERE IT BECOMES NECESSARY TO DRILL INTO OR CUT THROUGH ANY EXISTING FLOORS, WALLS OR CEILINGS TO PERMIT THE INSTALLATION OF ANY WORK UNDER THIS CONTRACT, SUCH CUTTING AND PATCHING SHALL BE PERFORMED BY TRADESMEN EXPERIENCED IN THE WORK REQUIRED. CONTRACTOR SHALL PAY FOR ALL COSTS REQUIRED FOR DRILLING, CUTTING AND/OR REPAIRING. ALL FINISHES SHALL MATCH EXISTING AND/OR NEW ADJACENT SURFACES. PROVIDE X-RAYS AS REQUIRED. 23.ALL EXTERIOR EQUIPMENT SHALL BE WEATHERPROOF. 24.ALL EQUIPMENT SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT INSTALLED, INCLUDING BUT NOT LIMITED TO : FREEZERS, COOLERS, CLEAN ROOMS, FOOD PROCESS AREAS, WASH DOWN AREAS, OUTDOORS AND CLASSIFIED AREAS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE APPROPRIATELY RATED EQUIPMENT WHETHER SPECIFIED IN THESE DRAWING OR NOT. 25.WHERE THE SCOPE OF WORK INCLUDES NEW WORK IN EXISTING SWITCHBOARDS, PROVIDE SEPARATE LINE ITEM COST IN BID TO CLEAN SWITCHBOARD AND RETORQUE LUGS WITHIN SWITCHBOARD TO MEET MANUFACTURES SPECIFICATIONS. 26.IT IS UNDERSTOOD AND AGREED THAT THIS CONTRACT DOES NOT CONTEMPLATE THE HANDLING OF ASBESTOS, PCB OR ANY HAZARDOUS WASTE MATERIAL. IF ASBESTOS, PCB OR ANY HAZARDOUS WASTE MATERIAL IS ENCOUNTERED, NOTIFY THE OWNER IMMEDIATELY. DO NOT DISTURB, HANDLE OR ATTEMPT TO REMOVE. 27.ALL ELECTRICAL EQUIPMENT SHALL BE BRACED AND ANCHORED PER STATE AND LOCAL SEISMIC REQUIREMENTS. PART 2 - MATERIAL A.PULL BOXES 1.SIZES AS INDICATED ON THE DRAWINGS AND IN NO CASE OF LESS SIZE OR MATERIAL THICKNESS THAN REQUIRED BY THE GOVERNING CODE. EXERCISE CARE IN LOCATING UNDERGROUND PULL BOXES TO AVOID INSTALLATION IN DRAIN WATER FLOW AREAS. 2.GENERAL PURPOSE SHEET STEEL PULL BOXES: INSTALL ONLY IN DRY PROTECTED LOCATIONS WITH REMOVABLE SCREW COVERS. MANUFACTURER'S STANDARD BAKED ENAMEL FINISH. 3.ALL WEATHERPROOF JUNCTION BOXES SHALL BE "FS" TYPE, OTHERS SHALL NOT BE ACCEPTED. 4.CONCRETE PULL BOXES: FURNISH COMPLETE WITH PULLING IRONS, HOT-DIP GALVANIZED TRAFFIC COVER WITH HOT-DIP GALVANIZED FRAME AND 4 GALVANIZED CABLE RACKS WITH PORCELAIN BLOCKS. THE BOX TO BE SET ON A PEA GRAVEL BASE 12" THICK AND AS LARGE AS THE BOTTOM. PROVIDE PREFABRICATED PULL BOXES AS MANUFACTURED BY QUIKSET OR BROOKS PRODUCTS. SUBMIT SHOP DRAWINGS FOR APPROVAL. REFER TO DRAWINGS FOR SIZE. PROVIDE BEAD WELD ON COVER TO PULL BOX TO INDICATE SERVICES WITHIN PULL BOX (I.E. - "480/277-VOLT, 3-PHASE, 4-WIRE ELECTRICAL" OR "SIGNAL /TEL /P.A. /CLOCK /FIRE ALARM"). B.SWITCHES 1.PROVIDE CIRCUIT SWITCHES TOTALLY ENCLOSED, BAKELITE OR COMPOSITION BASE, TOGGLE TYPE WITH 120/277 VOLT A.C. RATING FOR FULL CAPACITY OR CONTACTS FOR LED, INCANDESCENT, FLUORESCENT, HID, OR MOTOR LOADS AS APPLICABLE. SWITCH RATINGS SHALL BE 20 AMPERE MINIMUM. COLOR SHALL BE WHITE OR AS SELECTED BY ARCHITECT. CONTRACTOR SHALL CONFIRM COLOR WITH ARCHITECT PRIOR TO ORDERING. C.RECEPTACLES 1.ALL RECEPTACLES IN FLUSH TYPE OUTLET BOXES SHALL BE INSTALLED WITH A BONDING JUMPER TO CONNECT THE BOX TO THE RECEPTACLE GROUND TERMINAL. GROUNDING THROUGH THE RECEPTACLE MOUNTING STRAPS IS NOT ACCEPTABLE. BONDING JUMPER, SIZED PER CODE, SHALL BE ATTACHED AT EACH OUTLET TO THE BACK OF THE BOX USING DRILLED AND TAPPED HOLES AND WASHER HEAD SCREWS 6-32 OR LARGER (EXCEPT ISOLATED GROUND RECEPTACLES). COLOR SHALL BE WHITE W ITH MATCHING COVER PLATE OR AS SELECTED BY ARCHITECT. CONTRACTOR SHALL CONFIRM COLOR WITH ARCHITECT PRIOR TO ORDERING. RECEPTACLES CONNECTED TO EMERGENCY POWER CIRCUITS SHALL BE RED, ISOLATED GROUND SHALL BE ORANGE. 2.DUPLEX CONVENIENCE RECEPTACLES SHALL BE GROUNDING TYPE, 125 VOLT, 20 AMPERE AND SHALL HAVE TWO CURRENT CARRYING CONTACTS AND ONE GROUNDING CONTACT WHICH IS INTERNALLY CONNECTED TO THE FRAME. OUTLET SHALL ACCOMMODATE STANDARD PARALLEL BLADE CAP AND SHALL BE SIDE WIRED. ONLY THESE RECEPTACLES LISTED HEREAFTER SHALL BE USED. 3.GROUND FAULT CONVENIENCE RECEPTACLES PROVIDE SEPARATE GROUND FAULT RECEPTACLE AT EACH LOCATION INDICATED ON DRAWINGS. 4.WEATHERPROOF RECEPTACLE: GROUND FAULT TYPE DUPLEX RECEPTACLE, MOUNTED IN A FLUSH OR SURFACE OUTLET BOX AS NOTED WITH SPRING DOOR TYPE COVERS. 5.SPECIAL OUTLETS SHALL BE AS INDICATED ON THE DRAWINGS. 6.FLUSH FLOOR DUPLEX CONVENIENCE RECEPTACLE IN A CAST IRON FLOOR BOX AS HEREIN BEFORE SPECIFIED SHALL BE GROUNDING TYPE, 125 VOLTS, 20 AMPERES, AND SHALL HAVE TWO CURRENT CARRYING CONTACTS AND ONE GROUNDING CONTACT WHICH IS INTERNALLY CONNECTED TO THE FRAME. RECEPTACLE SHALL BE P & S OR HUBBELL #5242, SIERRA #1410 OR LEVITON #5014, WITH STANDARD LENGTH MOUNTING STRAP AS REQUIRED BY THE MANUFACTURER OF FLOOR BOX BEING FURNISHED (OR AS SHOWN ON PLANS). D.DISCONNECTS 1.DISCONNECT SWITCHES SHALL BE RATED 600 VOLT A.C., HEAVY DUTY, QUICK-MAKE, QUICK-BREAK, HORSEPOWER RATED, NON-FUSIBLE OR FUSIBLE, CLASS "R", IN NEMA TYPE 1 ENCLOSURE, LOCKABLE WITH NUMBER OF POLES AND AMPERAGE AS INDICATED ON THE DRAWINGS. WHERE ENCLOSURE IS EXPOSED TO WEATHER OR IS INDICATED WP (WEATHERPROOF) SWITCHES SHALL BE NEMA TYPE 3R. 2.ALL FUSED DISCONNECT SWITCHES SHALL BE FUSED PER ASSOCIATED EQUIPMENT NAMEPLATE. E.TRANSFORMERS 1.TRANSFORMERS SHALL BE COPPER WOUND W/ 80 DEGREE C RISE AND A MINIMUM OF (4) 2 1/2% FULL CAPACITY PRIMARY TAPS. VOLTAGES SHALL BE AS SPECIFIED ON SINGLE LINE. PROVIDE VIBRATION ISOLATORS AT FOUR CORNERS. TRANSFORMERS SHALL BE MOUNTED SUCH THAT ALL MANUFACTURERS AND CODE REQUIRED CLEARANCES ARE MAINTAINED. ALL TRANSFORMERS SHALL BE COMPLETELY ENCLOSED EXCEPT FOR VENTILATING OPENINGS. 2.ALL DRY-TYPE TRANSFORMERS, RATED AT 15KVA OR GREATER, SHALL MEET THE ENERGY EFFICIENCY REQUIREMENTS OF THE DOE 2016. 3.TRANSFORMERS RATED OVER 112 1/2 KVA SHALL HAVE CLASS 155 OR HIGHER INSULATION SYSTEMS AND BE COMPLETELY ENCLOSED EXCEPT FOR VENTILATING OPENINGS. 4.WALL MOUNTED TRANSFORMERS SHALL UTILIZE MANUFACTURES MOUNTING BRACKETS. CONTRACTOR IS RESPONSIBLE TO COORDINATE WITH STRUCTURAL TO INSURE WALL IS CAPABLE OF SUPPORTING TRANSFORMER AND COMPLIES WITH ALL CODES. F.SPARE FUSE CABINETS 1.WHERE NEW FUSED SWITCHBOARDS OR FUSED MOTOR CONTROL CENTERS ARE INSTALLED, PROVIDE A CABINET WITH SPARE FUSES NEAR EACH ENCLOSURE. CABINETS SHALL BE AS SPECIFIED FOR "TERMINAL CABINETS" AND SHALL BE OF SUFFICIENT SIZE TO CONTAIN ALL SPARE FUSES SPECIFIED HEREIN. PROVIDE CLIPS (2 PER FUSE) FOR EACH SPARE FUSE. PROVIDE (3) SPARE FUSES FOR EACH TYPE/SIZE ON PROJECT. MOUNT CLIPS IN PLYWOOD BACKBOARD IN CABINET. LABEL CABINET "SPARE FUSES". INCLUDE FUSE PULLER. G.CONDUIT 1.ALL CONDUIT SHALL BE UTILIZED AND INSTALLED PER CODE. ALL CONDUIT SHALL BE SUPPORTED AND BRACED PER APPLICABLE CODES WITH PIPE CLAMPS & SUPPORTS, PLUMBERS TAPE SHALL NO BE ACCEPTED. 2.ALL CONDUIT SHALL BE CONCEALED FROM VIEW WHEREVER POSSIBLE. 3.ALL EXPOSED CONDUIT SHALL BE INSTALLED AT RIGHT ANGLES OR PARALLEL TO WALLS OR STRUCTURES AND SHALL BE INSTALLED IN A CLEAN, WORKMAN LIKE MANNER. CONTRACTOR SHALL PAINT EXPOSED CONDUIT TO MATCH SURROUNDING SURFACE COLOR. CONTRACTOR SHALL OBTAIN PAINT MANUFACTURES NAME AND COLOR NUMBERS FROM ARCHITECT OR OWNERS REPRESENTATIVE. 4.RIGID STEEL CONDUIT SHALL BE USED WHERE EMBEDDED IN CONCRETE; EMBEDDED IN BRICK OR MASONRY WALLS; EXPOSED ON INTERIOR OF BUILDINGS BELOW EIGHT FEET WHERE SUBJECT TO PHYSICAL DAMAGE; EXPOSED ON EXTERIOR OF BUILDING; DAMP OR WET LOCATIONS; EXPOSED ON ROOF OR IN CLASSIFIED AREAS. RIGID STEEL CONDUIT SHALL NOT BE INSTALLED IN DIRECT CONTACT WITH EARTH OR SAND. 5.CONDUITS PENETRATING THRU SLAB SHALL BE RIGID GALVANIZED STEEL. 6.EMT SHALL BE INSTALLED IN DRY LOCATIONS SUCH AS, PARTITIONS, CEILING SPACES AND STUD WALLS, OR WHERE EXPOSED BELOW EIGHT FEET AND NOT SUBJECT TO PHYSICAL DAMAGE. 7.IMT SHALL BE USED WHERE EXPOSED BELOW EIGHT FEET AND SUBJECT TO PHYSICAL DAMAGE. 8.FLEXIBLE STEEL CONDUIT MAY BE INSTALLED WHERE CONCEALED ABOVE CEILING OR IN NON-MASONRY/CONCRETE WALLS AND PROPERTY SUPPORTED. 9.LIQUID-TIGHT FLEXIBLE CONDUIT SHALL BE INSTALLED FOR FINAL CONNECTION TO MOTORS, CONTROL DEVICES MOUNTED ON VIBRATING OR ROTATING EQUIPMENT, EQUIPMENT INDICATED ON DRAWINGS TO HAVE FLEXIBLE CONNECTIONS, AND IN ALL AREAS WHERE EXPOSED TO MOISTURE AND FLEXIBLE CONNECTIONS ARE REQUIRED. ALL FLEXIBLE CONDUIT SHALL CONTAIN A GROUND CONDUCTOR SIZED PER CODE. 10.SCHEDULE 40 PVC CONDUIT WITH CODE SIZED GROUND CONDUCTOR SHALL BE USED BELOW GRADE ONLY, IF APPROVED AND INSTALLED PER LOCAL CODES UNLESS OTHERWISE SPECIFIED. DO NOT ROUTE BELOW GRADE CONDUITS THROUGH AREAS OF FUTURE CONSTRUCTION. INSTALL 30" BELOW GRADE. PROVIDE PVC-COATED STEEL CONDUIT FOR ALL ELBOWS AND RISERS. NON-METALLIC CONDUIT SHALL NOT BE INSTALLED IN; CONCRETE BUILDINGS, BRICK OR MASONRY CONSTRUCTION; IN WALLS; ABOVE CEILINGS OR IN CRAWL SPACES. 11.MC CABLE IS ACCEPTABLE IN AREAS WHERE NOT SUBJECT TO DAMAGE SUCH AS IN FURRED OUT WALLS AND ABOVE CEILINGS PROVIDED ALL SUPPORT REQUIREMENTS ARE MET AND PROVIDE IT IS INSTALLED AS FOLLOWS: TRADITIONAL CONDUIT/WIRE SYSTEM SHALL BE USED FROM THE PANEL TO AN ACCESSIBLE SPACE IN THE CEILING. A CODE SIZE JUNCTION BOX/BOXES SHALL BE INSTALLED IN THE ACCESSIBLE CEILING AREA. THHN/THWN, 90 DEGREE CONDUCTORS IS THEN PULLED FROM THE J-BOX TO THE PANEL WHERE THE CONDUCTORS ARE TERMINATED ON THE BREAKERS. FROM THE J-BOX IN THE CEILING, MC CABLE, WITH THE FULLY RATED GROUND, MAY THEN BE RUN TO THE BRANCH DEVICE. THE METHOD USED TO CUT THE MC CABLE IS DONE WITH MANUFACTURER APPROVED TOOLS ONLY. SPECIFICALLY A TOOL DESIGNED TO CUT THE METAL JACKET WITHOUT DAMAGING THE WIRE INSIDE. AFTER THE JACKET HAD BEEN CUT, A PLASTIC BUSHING IS INSERTED TO FURTHER PROTECT THE WIRING. THEN TEST ALL CIRCUITS TO ENSURE POLARITY, VOLTAGE AND GROUNDING. 12.ALL CONDUIT PENETRATIONS THROUGH FIRE-RATED FLOOR SLABS, SHAFTS AND WALLS SHALL BE SEALED TO PREVENT THE SPREAD OF FIRE OR SMOKE WITH AN APPROVED UL LISTED FIRE STOP OR FIRE RESISTANT SEALANT. THE RATING OF THE FIRE STOP OR SEALANT SHALL BE EQUAL TO THE RATING OF THE ELEMENT PENETRATED. 13.CONDUITS REFERENCED AS CONDUIT ONLY (C.O.) SHALL BE CAPPED AND PROVIDED WITH A NYLON PULL STRING AND TAGS INDICATING THE ORIGINATION AND FUNCTION FOR THE CONDUIT. 14.PREMANUFACTURE CONDUIT SYSTEMS MAY BE USED FOR LIGHTING SYSTEMS. CONTRACTOR SHALL FURNISH COMPLETE SYSTEM WITH U.L. LISTED COMPONENTS AS APPROVED BY LOCAL JURISDICTION. CONTRACTOR SHALL PROVIDE SHOP DRAWING OF ENTIRE SYSTEM INDICATING ALL DEVICES, CONDUIT LENGTHS AND SUPPORTS. SYSTEM SHALL BE 277/480 OR 120/208 VOLT RATED. 15.CONDUITS CROSSING BUILDING EXPANSION AND/OR SEISMIC JOINTS SHALL BE PROVIDED WITH EXPANSION DEFLECTION FITTINGS AT THE EXPANSION AND/OR SEISMIC JOINT. 16.ALL CONDUIT FOR ROOFTOP EQUIPMENT SHALL BE ROUTED BELOW THE ROOF STRUCTURE. ALL PENETRATIONS THROUGH ROOF OR EXTERIOR WALL SHALL BE FLASHED AND MADE WATER-TIGHT. PROVIDE ROOF JACKS AT ALL PENETRATIONS. 17.CONTRACTOR SHALL PROVIDE CONDUIT SEALS AS REQUIRED BY CODE. 18.CONDUITS USED FOR EQUIPMENT GROUNDING SHALL UTILIZE APPROVED GROUNDING COUPLINGS. 19.ALL CONDUITS SHALL INCLUDE A GREEN EQUIPMENT GROUND SIZED PER CODE, #12 AWG MINIMUM. 20.MINIMUM ABOVE GROUND CONDUIT SIZE SHALL BE 1/2". MINIMUM UNDERGROUND CONDUIT SIZE SHALL BE 3/4". 21.ALL EMPTY CONDUITS SHALL INCLUDE A NYLON PULL LINE AND SHALL BE CAPPED AND PERMANENTLY MARKED TO IDENTIFY ITS PURPOSE AND WHERE IT TERMINATES. H.CONDUCTORS 1.ALL CONDUCTORS SHALL BE COPPER, 600V AND RATED 90 DEGREE C. PROVIDE TYPE THHN IN DRY LOCATIONS AND TYPE THWN-2 IN WET (OR DRY) LOCATIONS. MINIMUM SIZE #12 AWG. 2.WHERE INSTALLED IN RACEWAY, CONDUCTORS OF SIZE NO.8 AND LARGER SHALL BE STRANDED. 3.CONDUCTORS SIZE NO. 1 AWG AND SMALLER WITH 90 DEGREE C INSULATION ARE TO USE THE 60 DEGREE C COLUMN OF THE CODE, TABLE 310.15(B)(16), TO DETERMINE AMPACITY. CONDUCTORS #1/0 AWG AND LARGER WITH 90 DEGREE C INSULATION ARE TO USE THE 75 DEGREE C COLUMN OF THE CODE, TABLE 310.15(B)(16), TO DETERMINE AMPACITY. 4.ALL CONDUCTORS/CABLING SHALL BE INSTALLED IN AN APPROVED RACEWAY UNLESS SPECIFICALLY OTHERWISE NOTED. I.PANELBOARDS, SWITCHBOARDS AND DISTRIBUTION BOARDS 1.ENCLOSURES SHALL BE NEMA 1 FOR INDOOR AND NEMA 3R FOR OUTDOOR USE. ALL SWITCHBOARDS SHALL BE PAINTED MANUFACTURERS STANDARD GRAY OVER A RUST INHIBITING PRIMER ON CORROSIVE RESISTANT METAL SURFACE. SWITCHBOARD SHALL BE NEW AND FREE OF ANY SCRATCHES, DENTS OR ANY DAMAGE. 2.ALL BUSSING SHALL BE PLATED COPPER UNLESS OTHERWIISE NOTED WITH BRACING PER SINGLE LINE DIAGRAM. THE AIC RATING SHALL NEVER BE LESS THAN THE UTILITY COMPANY AVAILABLE FAULT CURRENT. CONTRACTOR SHALL VERIFY THE FAULT CURRENT WITH UTILITY COMPANY PRIOR TO ORDERING GEAR TO ENSURE PROPER BRACING AND SERIES RATING. SWITCHBOARDS SHALL BE APPROVED BY THE UTILITY COMPANY SERVING THE PROJECT. 3.ALL PANELBOARDS SHALL BE U.L. LISTED FOR SERIES RATING COMBINATION FUSE TO CIRCUIT BREAKER OR CIRCUIT BREAKER TO CIRCUIT BREAKER ARRANGEMENT. ALL BUSSING SHALL BE PLATED COPPER AND ALL CIRCUIT BREAKERS SHALL BE BOLT-ON TYPE. 4.PANELBOARDS SHALL BE MOUNTED AS SHOWN ON DRAWINGS. PROVIDE CIRCUIT BREAKERS AS SHOWN ON PANEL SCHEDULES AND SINGLE LINE DIAGRAM. PROVIDE WITH HINGED DOORS, TYPED PANEL CARDS AND PROPER BUSSING. 5.ALL PANELBOARDS AND CONTROL CABINETS SHALL BE LOCKABLE AND KEYED ALIKE. 6.THE UNDERGROUND PULL SECTION SHALL BE SIZED PER PLANS AND UTILITY COMPANY REQUIREMENTS. IN NO CASE SHALL THE DIMENSIONS OF THE PULL SECTION BE LESS THAN REQUIRED BY THE SERVING UTILITY COMPANY. 7.THE METER/MAIN SECTION SHALL INCLUDE ALL METERING EQUIPMENT INCLUDING CURRENT TRANSFORMERS, SOCKET, TEST BLOCK AND METERING BARRIER SEPARATING METERING EQUIPMENT FROM MAIN DEVICE. THE MAIN SHALL BE A THERMAL MAGNETIC MOLDED CASE CIRCUIT BREAKER OR SOLID STATE CIRCUIT BREAKER. FUSIBLE SWITCHES SHALL NOT BE ACCEPTED UNLESS SPECIFICALLY SHOWN ON PLANS. 8.DISTRIBUTION BOARDS AND PANELBOARDS SHALL BE BY THE SAME MANUFACTURER AS UGPS AND METER/MAINS. 9.DIMENSIONS OF SWITCHGEAR DESIGN ARE TO BE USED IN LAYING OUT ELECTRICAL ROOM. ANY DEVIATIONS MAY VIOLATE CODE MINIMUM CLEARANCE. CONTRACTOR SHALL PROVIDE A SCALED AND DIMENSIONED PLAN OF ELECTRICAL ROOM SHOWING ACTUAL SWITCHBOARD SIZE AND EXACT LOCATION. THIS DRAWING SHALL BE FURNISHED WITH SHOP DRAWING SUBMITTAL. 10.DISTRIBUTION BOARDS SHALL BE FLOOR STANDING, FULL HEIGHT WITH MINIMUM OF 60 INCHES OF DISTRIBUTION AND CAPABLE OF HOUSING CIRCUIT BREAKER AS LARGE AS THE MAIN CIRCUIT BREAKER. THE BUSSING SHALL BE PLATED COPPER BRACED FOR 65,000 AMPS (UNLESS OTHERWISE NOTED ON PLANS). THE BUSSING SHALL MATCH UP WITH METER MAIN AND BOLT TOGETHER. CABLE CONNECTIONS SHALL NOT BE ACCEPTED UNLESS SPECIFICALLY SHOWN ON PLANS. CIRCUIT BREAKERS IN THESE SECTIONS SHALL HAVE THE SAME INTERRUPTING RATING AS THE MAIN CIRCUIT BREAKER. CIRCUIT BREAKERS DOWN STREAM SHALL BE SERIES RATED AND SHALL BARE ALL TAGS AND CODE REQUIRED IDENTIFICATION. 11.HORIZONTAL AND VERTICAL BUSSES SHALL BE FULL LENGTH. BUSS SHALL HAVE A MINIMUM WITHSTAND RATING EQUAL TO AVAILABLE FAULT CURRENT INDICATED ON DRAWINGS, BUT IN NO CASE SHALL THE RATING BE LESS THAT 65,000 AMPS, SYMMETRICAL UNLESS SPECIFICALLY SHOWN ON PLANS. 12.PROVIDE INTERCONNECTED FULL CAPACITY NEUTRAL BUS IN EACH SECTION WITH THE SAME RATINGS AND CONSTRUCTION AS THE PHASE BUSSES. 13.PROVIDE INTERCONNECTED GROUND BUS IN EACH SECTION. 14.PROVIDE SPACE AND ALL HARDWARE AND MOUNTING ATTACHMENTS FOR FUTURE DEVICES AS INDICATED ON THE DRAWINGS. 15.MAIN HORIZONTAL BUSSING SHALL BE FULL CAPACITY IN ALL SWITCHBOARD SECTIONS. 16.VERTICAL BUSS MAY BE TAPERED, TO NOT LESS THAN ONE THIRD THE AMPACITY RATING OF THE MAIN HORIZONTAL BUSS; BUT IN NO CASE SHALL THE VERTICAL BUSS BE OF LESS CAPACITY THAN THE SUM OF THE FRAME SIZE AMPACITIES OF OVERCURRENT DEVICES MOUNTED IN THE RESPECTIVE SECTIONS INCLUDING ANY INDICATED SPARES AND SPACES. 17.THE SWITCHBOARD BUSSING SHALL BE OF SUFFICIENT CROSS-SECTIONAL AREA TO MEET UL STANDARD 891 ON TEMPERATURE RISE. BUS SHALL BE PLATED COPPER. THE THROUGH BUS SHALL HAVE PROVISIONS FOR THE ADDITION OF FUTURE SECTION. THE THROUGH BUS SUPPORTS, CONNECTIONS AND JOINTS ARE TO BE BOLTED WITH GRADE 5 HEX HEAD BOLTS AND BELLEVILLE WASHERS TO MINIMIZE MAINTENANCE REQUIREMENTS. J.OVERCURRENT DEVICES 1.ALL OVER CURRENT DEVICES, INCLUDING BUT NOT LIMITED TO, CIRCUIT BREAKERS, FUSED SWITCHED, COMBINATION MOTOR STARTERS, ETC. SHALL HAVE AN INTERRUPTING RATING EQUAL TO OR EXCEEDING THE AVAILABLE FAULT CURRENT, INCLUDING MOTOR CONTRIBUTION. CONTRACTOR SHALL VERIFY THE UTILITY CO. AVAILABLE FAULT CURRENT PRIOR TO ORDERING EQUIPMENT. IN THE EVENT THE AVAILABLE FAULT CURRENT IS HIGHER THAN SHOWN ON THE DRAWINGS, CONTRACTOR SHALL ADJUST, AT NO COST, AS REQUIRED. 2.ALL CIRCUIT BREAKERS SHALL BE BY THE SAME MANUFACTURE, AS INDICATED ON THE SINGLE LINE DIAGRAM AND PANEL SCHEDULES. 3.CIRCUIT BREAKERS SHALL BE ARRANGED IN PANELS SO THAT PROPER TRIP SETTINGS AND NUMBERS CORRESPOND TO THE PANEL SCHEDULES ON THE DRAWINGS. IN NO CASE SHALL THE CONTRACTOR MODIFY THE BREAKER CONFIGURATION UNLESS WRITTEN AUTHORIZATION IS GIVEN BY THE ENGINEER OF RECORD. 4.TWO OR THREE POLE CIRCUIT BREAKERS SHALL BE COMMON TRIP TYPE. SINGLE POLE BREAKERS WITH TIE-BAR BETWEEN HANDLES ARE NOT ACCEPTABLE. 5.WHERE BRANCH CIRCUITS FEED MOTORS, WATER HEATERS AND SIGNAL DEVICES, THE BREAKER SHALL BE PROVIDED WITH A PERMANENT LOCK-OFF DEVICE. 6.ALL PANELBOARD CIRCUIT BREAKERS SHALL BE BOLT-ON TYPE. 7.MAIN SERVICE DISCONNECT DEVICES SHALL BE CIRCUIT BREAKERS UNLESS OTHERWISE SPECIFIED IN PLANS. 8.MAIN SERVICE DISCONNECTS RATED 1000 AMPS OR MORE, SOLIDLY GROUND WYE WITH GREATER THAN 150 VOLTS TO GROUND AND BUT NOT EXCEEDING 600 VOLTS PHASE TO PHASE SHALL BE PROVIDED WITH A ZERO SEQUENCE GROUND FAULT DETECTION/INTERUPT DEVICE. ALL GROUND FAULT EQUIPMENT SHALL BE TESTED AND SET BY AN INDEPENDENT TESTING LABORATORY AND SHALL BE SET AS RECOMMENDED BY THE TESTING AGENCY SO AS TO BE COORDINATED WITH OTHER PROTECTION DEVICES WITHIN THE ELECTRICAL DESIGN. COPIES OF THE TEST AND SETTINGS SHALL BE SENT TO THE ARCHITECT. CONTRACTOR SHALL INCLUDE IN HIS BID ALL COST ASSOCIATED WITH TESTING AND SETTING OF GROUND FAULT DEVICES. 9.NEW CIRCUIT BREAKERS AND FUSIBLE SWITCHES INSTALLED IN EXISTING SWITCHBOARDS, DISTRIBUTION BOARDS AND PANELBOARDS SHALL MATCH EXISTING MANUFACTURER AND ALL ELECTRICAL CHARACTERISTICS OF THE EXISTING EQUIPMENT BUT IN NO CASE SHALL THE INTERRUPTING RATING BE LESS THAN THE AVAILABLE FAULT CURRENT, INCLUDING MOTOR CONTRIBUTION. 10.ALL FUSES SHALL BE CLASS "R" BUSS CO. LPN-RK (250V) OR LPS-RK (600V), UNLESS OTHERWISE NOTED. ALL FUSES SHALL PROPERLY SERIES RATE WITH DOWN STREAM DEVICES. K.LIGHT FIXTURES 1.ALL LIGHTING SHALL COMPLY WITH APPLICABLE ENERGY CODES WHETHER INDICATED IN THESE DRAWINGS OR NOT. 2.PROVIDE LIGHT FIXTURES COMPLETE WITH LAMPS, DRIVERS, BALLASTS, SOCKETS, HOUSINGS, CEILING TRIM RINGS FOR SPECIAL CEILINGS, BRACKETS, DIFFUSERS/LENSES AND OUTLET BOXES. 3.THE CATALOG NUMBERS INCLUDED IN THE FIXTURE SCHEDULE SHALL BE CONSIDERED TO ESTABLISH THE TYPE OR CLASS OF FIXTURE WITH A PARTICULAR MANUFACTURER ONLY. THE FIXTURE LENGTH, QUANTITY, TYPE OF LAMPS, COMPONENT MATERIALS, ACCESSORIES, MOUNTING TYPE AND ALL OTHER FEATURES REQUIRED TO FULFILL THE TOTAL DESCRIPTION OF THE FIXTURE BASED ON ALL DRAWINGS AND SPECIFICATION INFORMATION SHALL BE COMPLIED WITH REGARDLESS OF WHETHER OR NOT THE CATALOG NUMBER ON THE FIXTURE SCHEDULE SPECIFICALLY INCLUDES THESE FEATURES. IF ANY CONFLICT EXISTS BETWEEN THE CATALOG NUMBER, THE DESCRIPTION, OR FIELD CONDITIONS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND ENGINEER PRIOR TO ORDERING. 4.LIGHT FIXTURES SHALL BE OF TYPES AS INDICATED IN THE FIXTURE SCHEDULE ON THE DRAWINGS. 5.INCLUDE AN ALLOWANCE OF $500.00 FOR THE SUPPLY AND INSTALLATION OF LIGHT FIXTURE WHERE OUTLET IS SHOWN ON DRAWINGS WITHOUT A FIXTURE TYPE DESIGNATION. 6.ALL FIXTURES OF ONE TYPE SHALL BE OF ONE MANUFACTURER AND OF IDENTICAL FINISH AND APPEARANCE, UNLESS OTHERWISE NOTED ON DRAWINGS. 7.PROVIDE SEISMIC RESTRAINTS, AS REQUIRED, BY LOCAL JURISDICTION. 8.ALL LIGHT FIXTURES SHALL BE LED UNLESS OTHERWISE SPECIFIED IN THESE DRAWINGS. 9.ALL LIGHT FIXTURES SHOWN AS "EM" SHALL BE PROVIDED WITH EITHER AN INTEGRAL BATTERY PACK OR EXTERNAL EMERGENCY LIGHTING INVERTER. 10.ALL LIGHT FIXTURES SHALL MEET TITLE 20 AND TITLE 24 REQUIREMENTS WHETHER SHOWN ON PLANS OR NOT. 11.ALL LIGHT FIXTURES SHALL HAVE ALL PARTS AND FITTINGS NECESSARY TO COMPLETE AND PROPERLY INSTALL THE FIXTURE IN THE APPLICABLE LOCATION. 12.SURFACE AND/OR WALL MOUNTED LIGHTING FIXTURES SHALL NOT HAVE ANY EXPOSED CHASE NIPPLES OR CONDUIT KNOCKOUTS VISIBLE TO VIEW WITHIN FIXTURE HOUSING. LIGHTING FIXTURES MOUNTED IN CONTINUOUS ROWS SHALL HAVE CHASE NIPPLES OR CONDUIT KNOCKOUTS BETWEEN FIXTURE HOUSINGS, BUT SHALL NOT HAVE VISIBLE CHASE NIPPLE/CONDUIT KNOCKOUTS ON THE VISIBLE ENDS OF THE CONTINUOUS ROW LIGHTING FIXTURE. 13.WHERE FIXTURE COLOR IS INDICATED TO BE SELECTED BY THE ARCHITECT, PROVIDED TWO COLOR CHIP SAMPLES FOR REVIEW. 14.RECESSED FIXTURES MUST ALL BE U.L. APPROVED FOR RECESSED INSTALLATION WITH PLASTER FRAME AND ATTACHED PULLBOX. LAMP ENCLOSURE, REFLECTORS AND FINISH WIRING SHALL NOT BE INSTALLED UNTIL PLASTERING IS COMPLETE. FINISH TRIM SHALL NOT BE INSTALLED UNTIL FINISH PAINTING OF THE ADJACENT SURFACE IS COMPLETE. 15.ALL FIXTURES SHALL BEAR U.L. LABEL OF APPROVAL FOR FIXTURE WATTAGE INDICATED. 16.LIGHT FIXTURES INSTALLED IN DAMP OR WET LOCATIONS SHALL BE UL LISTED FOR SUCH LOCATION. 17.LIGHT FIXTURES INSTALLED IN CONTACT WITH INSULATION SHALL HAVE PROPER I.C. RATING WHETHER SHOWN ON PLANS OR NOT. FIXTURES WITHOUT I.C. RATING SHALL HAVE A SEPARATION OF 3" BETWEEN THE FIXTURE AND THE INSULATION. 18.FIXTURE LENSES AND DIFFUSERS SHALL BE AS CALLED OUT ON FIXTURE SCHEDULE. 19.ACRYLIC LENSES SHALL BE MANUFACTURED FROM 100% VIRGIN ACRYLIC AND BE .125" THICK MINIMUM. 20.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ACTUAL CEILING TYPE AS DEFINED ON THE ARCHITECTURAL DRAWINGS AND FURNISH ALL FIXTURES WITH THE CORRECT MOUNTING DEVICES AND PROPER OPERATING VOLTAGES. CONTRACTOR SHALL VERIFY DEPTH OF ALL RECESSED FIXTURES WITH ARCHITECTURAL DRAWINGS PRIOR TO ORDERING. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO ORDERING. 21.RECESSED LIGHT FIXTURES MOUNTED FLUSH IN "LAY-IN" T-BAR OR CONCEALED SPLINE CEILING SHALL BE PROVIDED WITH TWO CLIPS ON EACH END OF THE FIXTURE AND CONNECTED TO THE CEILING CROSS RUNNERS. PROVIDE TWO 12 GAUGE FIXTURE HANGER WIRE ATTACHED TO STRUCTURAL MEMBERS AND CONNECT TO DIAGONAL CORNERS OF FIXTURE. FIXTURE SHALL SET LEVEL AND FLUSH WITH CEILING GRID SYSTEM. 22.SURFACE MOUNTED FIXTURES INSTALLED ON DRY WALL OR PLASTER CEILINGS AND WEIGHING LESS THAN 50 POUNDS MAY BE SUPPORTED FROM OUTLET BOX. PROVIDE STRUCTURAL SUPPORTS ABOVE DRYWALL OR PLASTER CEILING FOR INSTALLATION OF FIXTURE WEIGHING MORE THAN 50 POUNDS AND SECURE FIXTURES TO STRUCTURAL SUPPORTS. THE USE OF TOGGLE BOLTS IS PROHIBITED. 23.LIGHT FIXTURES RECESSED IN CEILING OR DRY WALL WHICH HAS A FIRE RESISTIVE RATING OF ONE HOUR OR MORE SHALL BE ENCLOSED IN A BOX WHICH HAS A FIRE RATING EQUAL TO THAT OF THE CEILING OR WALL. THE SPACE FROM THE FIXTURE TO THE ENCLOSURE SHALL BE A MINIMUM OF 3". 24.LENS AND DIFFUSERS SHALL BE CLEANED COMPLETELY OF ALL DUST, DIRT, AND FINGERPRINTS AFTER THE INSTALLATION OF THE LIGHT FIXTURES, CEILING, PAINTING, AND PRIOR TO OCCUPANCY OF THE FACILITY BY OWNER. 25.PROVIDE ILLUMINATED EXIT SIGNS AS REQUIRED BY BUILDING DEPARTMENT OR FIRE MARSHALL. EXIT SIGNS SHALL HAVE SELF-CONTAINED EMERGENCY BATTERY PACKS. PROVIDE CIRCUITRY AS REQUIRED FOR EXIT SIGNS, VERIFY LOCATIONS. CONTRACTOR SHALL PROVIDE ADDITIONAL EXIT SIGNS AND CIRCUITRY AS REQUIRED WITHOUT ADDITIONAL COST. PART 3 - SYSTEMS L.GROUNDING 1.THE ELECTRICAL SYSTEM SHALL BE GROUNDED PER CODE. 2.EQUIPMENT GROUNDING SHALL BE PER 250.118. 3.THE MAXIMUM RESISTANCE TO GROUND SHALL NOT EXCEED 25 OHMS TO GROUND. 4.THE CONTRACTOR SHALL PROVIDE ALL INSTRUMENTATION AND TESTS FOR MEASURING THE RESISTANCE OF EACH PHASE TO GROUND. A PROPERLY CALIBRATED "MEGGER" TYPE INSTRUMENT SHALL BE USED. IN THE EVENT THAT HIGH RESISTANCE TO GROUNDS ARE FOUND THEY SHALL BE ISOLATED. MAKE PROPER CORRECTIONS TO RESTORE THE RESISTANCE TO AN ACCEPTABLE VALUE. M.MECHANICAL AND PLUMBING 1.CONTRACTOR SHALL INCLUDE ALL H.V.A.C. AND PLUMBING POWER AND CONTROL REQUIREMENTS IN BASE BID. REVIEW MECHANICAL AND PLUMBING DRAWINGS FOR FINAL REQUIREMENTS/ LOCATIONS. 2.VERIFY EXACT LOCATIONS AND ORIENTATION OF ALL MECHANICAL AND PLUMBING EQUIPMENT WITH MECHANICAL AND PLUMBING DRAWINGS. FIELD VERIFY CONDITIONS WITH MECHANICAL AND PLUMBING CONTRACTORS PRIOR TO ROUGH-IN. 3.COORDINATE WITH MECHANICAL AND PLUMBING DRAWINGS AND PROVIDE, INCLUDING BUT NOT LIMITED TO, ALL CONDUIT, WIRING, TIME CLOCKS, STARTERS, CONTROL DEVICES, RELAYS, DISCONNECT SWITCHES, ETC. FOR THE PROPER OPERATION OF THE MECHANICAL AND PLUMBING SYSTEMS. REFER TO THE MECHANICAL AND PLUMBING DRAWINGS AND ADDENDUMS FOR ADDITIONAL ELECTRICAL REQUIREMENTS. 4.ALL EQUIPMENT, ENCLOSURES, DEVICES, DISCONNECT SWITCHES, CONNECTIONS, ETC. LOCATED OUTDOORS OR IN WET LOCATIONS SHALL BE WEATHERPROOF. 5.PROVIDE WEATHERPROOF "WHILE-IN-USE", EXTRA-DUTY, GFCI RECEPTACLES WITHIN 25 FT. OF MECHANICAL AND PLUMBING EQUIPMENT WHETHER SHOWN ON THESE DRAWINGS OR NOT. N.COMMUNICATIONS 1.TELEPHONE AND DATA OUTLETS SHALL CONSIST OF A SINGLE-GANG BOX WITH (1) 3/4"C.O. STUBBED 6" ABOVE ACCESSIBLE CEILING WITH A NYLON PULL STRING. PROVIDE PLASTER RING AND A SINGLE-PORT FACE PLATE, COLOR SPECIFIED BY ARCHITECT, UNLESS OTHERWISE NOTED. 2.TELEPHONE AND DATA OUTLETS IN BUILDINGS SERVED BY A PLENUM RATED CEILING OR AS REQUIRED BY LOCAL AUTHORITY SHALL HAVE 3/4"C.O. WITH NYLON PULL STRING ROUTED TO THE NEAREST TELEPHONE BACKBOARD. 3.IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO VERIFY THE TELEPHONE SERVICE ENTRANCE REQUIREMENTS AND SYSTEM DISTRIBUTION REQUIREMENTS WITH THE SERVING LOCAL TELEPHONE UTILITY COMPANY AND APPROPRIATE VENDOR. O.OTHER TRADES 1.CONTRACTOR SHALL REVIEW DRAWINGS AND SPECIFICATIONS OF ALL OTHER TRADES, INCLUDING BUT NOT LIMITED TO, ARCHITECTURAL, MECHANICAL, PLUMBING, LANDSCAPE, REFRIGERATION, KITCHEN, FIRE ALARM, LIFE SAFETY, SPRINKLER, SECURITY, AUDIO/VISUAL AND COMMUNICATIONS AND INCLUDE IN HIS BID ALL ELECTRICAL POWER, CONTROLS, CONDUIT ETC. NECESSARY TO MAKE THESE SYSTEMS OPERABLE WHETHER INDICATED ON THESE DRAWINGS OR NOT. P.UTILITIES 1.CONTRACTOR SHALL INCLUDE IN HIS BID ALL TRENCHING, CONDUIT, CONCRETE ENCASEMENT, PULL BOXES STRUCTURES, FEES, ETC. AS NECESSARY TO PROVIDE A COMPLETE, OPERABLE SYSTEM PER THE SERVING UTILITY COMPANIES REQUIREMENTS. 2.CONTRACTOR SHALL BUILD PER THE UTILITY COMPANIES ENGINEERED DRAWINGS ONLY. 3.CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND UTILITY COMPANY REQUIREMENTS PRIOR TO BID. NAME TYPE WATTS ID # ID SHEET ID SHEET ELECTRICAL EQUIPMENT -NO PREFIX: PANEL BOARD -T- OR XFMR PREFIX: TRANSFORMER -LCP PREFIX: LIGHTING CONTROL PANEL -DB PREFIX: DISTRIBUTION BOARD -MSB PREFIX: MAIN SWITCHBOARD -MSG PREFIX: MAIN SWITCHGEAR -INV PREFIX: INVERTER -MCC PREFIX: MOTOR CONTROL CENTER LIGHT FIXTURE -TYPE IS LIGHT FIXTURE DESIGNATION -WATTS IS LIGHT FIXTURE INPUT WATTAGE MECHANICAL, PLUMBING AND OTHER EQUIPMENT -ID IS EQUIPMENT DESIGNATION -# IS UNIT NUMBER DETAIL -ID IS DETAIL DESIGNATION -SHEET IS LOCATION OF DETAIL MATCH LINE -ID IS MATCH LINE DESIGNATION -SHEET IS LOCATION OF CONTINUATION CALL OUTS MAY BE USED WITH OR WITHOUT LEADERS SCOPE OF WORK GENERAL ELECTRICAL SPECIFICATIONS SHEET INDEX E0.1 SPECIFICATIONS AND ABBREVIATIONS E0.2 GENERAL NOTES AND SYMBOLS E1.1 OVERALL KEY PLAN E2.1 PARTIAL SINGLE LINE DIAGRAM E4.1 LAB POWER PLAN E4.2 ROOF POWER PLAN E4.5 LAB LIGHTING PLAN E4.6 NORMAL PHOTOMETRICS E4.7 EGRESS PHOTOMETRICS E5.1 SCHEDULES E6.1 EQUIPMENT SCHEDULE AND DETAILS E8.1 TITLE 24 ENERGY FORMS E0.1 SPECIFICATIONS AND ABBREVIATIONSPOWER AND LIGHTING FOR A NEW LAB AREA IN AN EXISTING BUILDING. REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 23 2 7 6 S O U T H P O I N T E D R . , U N I T 1 0 2 , LA G U N A H I L L S , C A 9 2 6 5 3 O: 9 4 9 - 4 1 9 - 9 9 0 8 F : 9 4 9 - 4 1 9 - 9 8 7 0 LE A V E B L A N K F O R C I T Y S T A M P 3009 S Daimler St 11/18/2024 GENERAL POWER NOTES (UNLESS OTHERWISE NOTED, SOME MAY NOT APPLY) A.CONTRACTOR SHALL VERIFY ALL LOCATIONS, MOUNTING HEIGHTS, CONNECTIONS AND REQUIREMENTS WITH OTHER TRADES, OWNER, ARCHITECT AND/OR TENANT AS APPLICABLE PRIOR TO INSTALL AND ADJUST ACCORDINGLY. CONTRACTOR SHALL REVIEW ALL OTHER TRADE'S DRAWINGS AND INCLUDE IN HIS BID ALL COSTS APPLICABLE TO THE ELECTRICAL TRADE WHETHER SHOWN IN THESE DRAWINGS OR NOT. B.WHERE NEW CONDUITS ARE TO BE INSTALLED UNDERGROUND, CONTRACTOR SHALL EMPLOY DIG-ALERT AND PROVIDE X-RAYS AS REQUIRED TO PREVENT DAMAGE TO EXISTING UNDERGROUND UTILITIES. CONTRACTOR SHALL INCLUDE ALL COSTS TO SAW CUT, TRENCH, BACK FILL, COMPACT AND PATCH TO MATCH EXISTING. C.ALL UNDERGROUND CONDUITS SHALL BE 3/4" MINIMUM. D.ALL CONDUITS SHALL BE ROUTED BELOW ROOF STRUCTURE. ALL ROOF PENETRATIONS SHALL BE SEALED AND WEATHERPROOFED. PROVIDE ROOF JACKS AT ALL PENETRATIONS. E.WHERE CIRCUIT CONDUCTOR SIZE EXCEEDS THE LUG RATING OF THE CIRCUIT BREAKER, PROVIDE A LISTED PIN ADAPTOR. IF A LISTED PIN ADAPTOR IS NOT AVAILABLE, PROVIDE A SPLICE BOX DIRECTLY ABOVE THE PANEL AND REDUCE THE CONDUCTOR TO THE MAXIMUM SIZE FOR WHICH THE CIRCUIT BREAKER IS LISTED. F.ALL 20A-125V RECEPTACLES LOCATED WITH 6FT OF A SINK SHALL BE GFI TYPE WHETHER INDICATED ON PLANS OR NOT. G.CONTRACTOR SHALL PROVIDE FINAL CONNECTIONS TO ALL HARDWIRED EQUIPMENT. UTILIZE CONDUIT AND CONDUCTOR SIZE SHOWN. WHERE APPLICABLE, FINAL 24" OF CONDUIT SHALL BE LIQUID TIGHT FLEXIBLE METAL CONDUIT SIZED PER CODE. H.PROVIDE PROTECTIVE, REMOVABLE STEEL BOLLARD AS REQUIRED TO PROTECT ELECTRICAL EQUIPMENT FROM VEHICULAR AND FORKLIFT TRAFFIC. MAINTAIN CODE REQUIRES CLEARANCE. GENERAL LIGHTING NOTES (UNLESS OTHERWISE NOTED, SOME MAY NOT APPLY) A.CONTRACTOR SHALL VERIFY ALL LOCATIONS, MOUNTING HEIGHTS, CONNECTIONS AND REQUIREMENTS WITH OTHER TRADES, OWNER, ARCHITECT AND/OR TENANT AS APPLICABLE PRIOR TO INSTALL AND ADJUST ACCORDINGLY. CONTRACTOR SHALL REVIEW ALL OTHER TRADE'S DRAWINGS AND INCLUDE IN HIS BID ALL COSTS APPLICABLE TO THE ELECTRICAL TRADE WHETHER SHOWN IN THESE DRAWINGS OR NOT. B.PROVIDE A COMPLETE MANUFACTURED WIRING SYSTEM FOR ALL LIGHT FIXTURES IN ACCESSIBLE CEILINGS. SYSTEM SHALL INCLUDE ALL CONNECTIONS TO FIXTURES AND CONTROLS WITH ALL REQUIRED SYSTEM COMPONENTS. MANUFACTURER SHALL PROVIDE SUBMITTALS FOR INSTALLATION WITH ALL PART NUMBERS. EQUIPMENT SHALL BE AMERICAN CABLE COMPANY. EMERGENCY FIXTURES AND NIGHT LIGHTS SHALL BE CONNECTED WITH TRADITIONAL CONDUIT AND CONDUCTORS TO EMERGENCY CIRCUIT. MANUFACTURED WIRING SYSTEM SHALL ONLY BE USED FOR NORMAL CIRCUITS AS SHOWN ON PLAN. C.ALL EMERGENCY "EM" LIGHT FIXTURES SHALL BE WIRED AND/OR PROGRAMMED TO TURN "ON", "OFF" AND/OR DIM AS APPLICABLE WITH AREA CONTROLS. WHEN NORMAL POWER FAILS, THE EMERGENCY FIXTURES SHALL ILLUMINATE AT FULL BATTERY OUTPUT, REGARDLESS OF THE AREA CONTROL POSITION. D.ALL EMERGENCY "EM" LIGHT FIXTURES WITH INTEGRAL BATTERY PACKS SHALL HAVE THEIR BATTERY PACKS CONNECTED TO THE AREA'S UNSWITCHED CIRCUIT AS REQUIRED. E.ALL WALL MOUNTED LIGHTING CONTROL DEVICES SHALL BE MOUNTED AT +44"AFF. F.PROVIDE NEUTRAL CONDUCTOR DOWN TO ALL LINE VOLTAGE SWITCHES AND MOTION SENSORS, PER 404.2(C). G.CONTRACTOR SHALL PROVIDE ALL CAT 5 CONNECTIONS BETWEEN DEVICES AS REQUIRED TO MAKE SYSTEM OPERABLE. H.CONTRACTOR SHALL PROVIDE ALL 0-10V DIMMING CONNECTIONS BETWEEN DEVICES AS REQUIRED TO MAKE SYSTEM OPERABLE. PROVIDE ADDITIONAL POWER PACKS FOR FIXTURES WITH 0-10 VOLT DIMMING AS REQUIRED. I.CONTRACTOR SHALL ADJUST LOCATION OF SENSORS AND/OR ADD ADDITIONAL SENSORS AS REQUIRED TO MAKE SYSTEM OPERABLE IN FINAL SPACE CONFIGURATION. CONTRACTOR SHALL ALSO INCLUDE IN HIS BID COST TO ADJUST PROGRAMMING TO MEET TENANT REQUIREMENTS BUT IN NO CASE SHALL SUCH ADJUSTMENTS VIOLATE CODE. J.CONTRACTOR SHALL VERIFY EXIT SIGN LOCATIONS, MOUNTING HEIGHTS WITH ARCHITECT. CONTRACTOR SHALL COORDINATE DIRECTIONAL ARROWS AND FACES WITH ARCHITECT. CONTRACTOR SHALL ADD ADDITIONAL EXIT SIGNS AS DIRECTED BY AUTHORITY HAVING JURISDICTION. K.CONTRACTOR SHALL INCLUDE IN HIS BID ALL CONDUIT, WIRE, EQUIPMENT, LABOR, TESTING, ETC., NECESSARY TO PROVIDE A COMPLETE, OPERABLE AND CODE COMPLIANT SYSTEM. CONTRACTOR SHALL VERIFY ALL LOCATIONS PRIOR TO INSTALL. PROVIDE 20A-120V DOUBLE DUPLEX RECEPTACLE. ONE DUPLEX SHALL BE CONTROLLED PER TITLE 24 AND THE OTHER SHALL BE UNCONTROLLED. CONTROLLED RECEPTACLE SHALL BE BLACK IN COLOR (OR GREEN IF AVAILABLE). COORDINATE EXACT COLOR WITH ARCHITECT. THE CONTROLLED RECEPTACLE SHALL BE PERMANENTLY MARKED TO DIFFERENTIATE FROM THE UNCONTROLLED RECEPTACLE PER 406.3(E). PROVIDE 3#12-1#12G-1/2"C FROM RECEPTACLE TO ASSOCIATED J-BOX. ROUTE CONTROLLED RECEPTACLE CIRCUIT THROUGH THE APPLICABLE RECEPTACLE CONTROL POWER PACK, SENSOR SWITCH #nPP20 PL. PROVIDE A SEPARATE POWER PACK FOR EACH CONTROLLED CIRCUIT. POWER PACK SHALL BE CONTROLLED BY ROOM OCCUPANCY SENSOR(S). PROVIDE 20A-120V DUPLEX RECEPTACLE. ONE HALF OF THE DUPLEX SHALL BE CONTROLLED PER TITLE 24 AND THE OTHER HALF SHALL BE UNCONTROLLED. CONTROLLED OUTLET SHALL BE BLACK IN COLOR (OR GREEN IF AVAILABLE). COORDINATE EXACT COLOR WITH ARCHITECT. THE CONTROLLED OUTLET SHALL BE PERMANENTLY MARKED TO DIFFERENTIATE FROM THE UNCONTROLLED OUTLET PER 406.3(E). PROVIDE 3#12-1#12G-1/2"C FROM RECEPTACLE TO ASSOCIATED J-BOX. ROUTE CONTROLLED OUTLET CIRCUIT THROUGH THE APPLICABLE RECEPTACLE CONTROL POWER PACK, SENSOR SWITCH #nPP20 PL. PROVIDE A SEPARATE POWER PACK FOR EACH CONTROLLED CIRCUIT. POWER PACK SHALL BE CONTROLLED BY ROOM OCCUPANCY SENSOR(S). ROUTE CONTROLLED RECEPTACLE CIRCUIT THROUGH POWER PACK, SENSOR SWITCH #nPP20 PL. PROVIDE SEPARATE POWER PACK FOR EACH CONTROLLED CIRCUIT. CONNECT TO ROOM OCCUPANCY SENSOR. WHERE OCCUPANCY SENSOR IS NOT SHOWN, PROVIDE A COMPATIBLE CEILING SENSOR. PROVIDE 20A-125V GFI DUPLEX RECEPTACLE. LOCATE RECEPTACLE BELOW SINK FOR GARBAGE DISPOSAL. PROVIDE 20A-120V SWITCH TO CONTROL RECEPTACLE. MOUNT SWITCH ABOVE COUNTER BACK SPLASH. PROVIDE 20A-125V GFI DUPLEX RECEPTACLE FOR DISHWASHER. MOUNT BELOW COUNTER. PROVIDE 20A-125V DUPLEX RECEPTACLE FOR UNDER CABINET REFRIGERATOR. MOUNT BELOW COUNTER. PROVIDE 20A-125V DUPLEX RECEPTACLE WITH (2) BUILT-IN USB CHARGING OUTLETS PER 406.3(F). VERIFY EXACT REQUIREMENTS PRIOR TO INSTALL. PROVIDE 20A-125V DUPLEX CLOCK RECEPTACLE FOR TELEVISION. MOUNT AT 80" AFF OR AS DIRECTED BY ARCHITECT. PROVIDE SINGLE GANG MUD RING AND COVER PLATE WITH 1-1/4" CO STUBBED 6" ABOVE ACCESSIBLE CEILING FOR AV OR AS DIRECTED BY OWNER. MOUNT ADJACENT TO RECEPTACLE. PROVIDE 20A-125V DUPLEX RECEPTACLE FOR TIME CLOCK. IN ADDITION, PROVIDE DATA OUTLET ADJACENT TO RECEPTACLE WITH 3/4"CO STUBBED 6" ABOVE ACCESSIBLE CEILING OR AS DIRECTED BY OWNER. PROVIDE RECEPTACLE OR HARDWIRE CONNECTION TO CONDENSATE PUMP AS REQUIRED BY MECHANICAL. WHERE HARDWIRE CONNECTION IS REQUIRED, PROVIDE A LOCAL DISCONNECT PER CODE. CONNECT TO CONDENSATE PUMP AS REQUIRED. PROVIDE 20A-125V GFI DUPLEX RECEPTACLE. FOR COUNTERS TOPS, MOUNT ABOVE BACK SPLASH OR AS DIRECTED BY ARCHITECT. OTHERWISE MOUNT AT 18" AFF. PROVIDE 20A-125V GFI DUPLEX RECEPTACLE FOR MICROWAVE. VERIFY EXACT LOCATION AND MOUNTING HEIGHTS PRIOR TO INSTALL. PROVIDE 20A-125V GFCI RECEPTACLE FOR PLUG-IN CIRCULATION PUMP WITH BUILT IN TIMER. VERIFY LOCATION WITH PLUMBING. MAINTAIN ACCESS. PROVIDE 20A-125V WP/WR/GFCI RECEPTACLES WITHIN 25FT OF ALL MECHANICAL EQUIPMENT. RECEPTACLES SHALL HAVE AN ENCLOSURE THAT IS WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG IS INSERTED. THE BOX SHALL BE LISTED AND IDENTIFIED AS "EXTRA DUTY" PER ART. 406.9. PROVIDE SINGLE GANG MUD RING, OR AS DIRECTED BY TENANT, WITH (1) 1"CO STUBBED 6" ABOVE ACCESSIBLE CEILING SPACE FOR DATA. MOUNT AT 18" AFF. PROVIDE PULL LINE. PROVIDE J-BOX IN CEILING FOR FUTURE CONNECTION TO POWER POLES AND POWER PARTITIONS. VERIFY LOCATION WITH ARCHITECT PRIOR TO INSTALL. PROVIDE 20A-125V DUPLEX RECEPTACLE IN CEILING FOR PROJECTOR. PROVIDE J-BOX IN CEILING FOR PROJECTOR SCREEN. CONNECT TO SCREEN AS REQUIRED. PROVIDE FLUSH IN-FLOOR FIRE RATED COMBINATION POWER / TELEPHONE / DATA POKE-THRU WITH QUADRAPLEX RECEPTACLE. PROVIDE WIREMOLD RC4 SERIES OR EQUAL. COORDINATE EXACT LOCATION, REQUIREMENTS AND FINISH WITH ARCHITECT PRIOR TO BID. ONE DUPLEX RECEPTACLE SHALL BE CONTROLLED PER TITLE 24 ENERGY CODE. PROVIDE FLUSH IN-FLOOR FIRE RATED COMBINATION POWER / TELEPHONE / DATA POKE-THRU FOR FURNITURE FEED. PROVIDE WIREMOLD FURNITURE FEED 4FFATC OR EQUAL. CONNECT TO PARTITION SYSTEM AS REQUIRED. COORDINATE EXACT LOCATION, REQUIREMENTS AND FINISH WITH ARCHITECT PRIOR TO BID. PROVIDE FLUSH IN-FLOOR CONCRETE RATED BOXES WITH QUADRAPLEX RECEPTACLE AND TELEPHONE/DATA OUTLETS. PROVIDE POWER CONNECTION AS SHOWN AND (1) 3/4"CO FOR TELEPHONE/DATA FROM DEVICE AND ROUTE TO NEAREST WALL. STUB TELEPHONE/DATA CONDUIT TO 6" ABOVE ACCESSIBLE CEILING SPACE. VERIFY EXACT LOCATION AND FINISH WITH ARCHITECT PRIOR TO BID. ONE DUPLEX RECEPTACLE SHALL BE CONTROLLED PER TITLE 24 ENERGY CODE. PROVIDE FLUSH IN-FLOOR CONCRETE RATED JUNCTION BOXES WITH PROVISIONS FOR WHIP CONNECTION TO MODULAR FURNITURE. PROVIDE POWER CONNECTION AS SHOWN AND (1) 1-1/4"CO FOR TELEPHONE/DATA FROM DEVICE AND ROUTE TO NEAREST WALL. STUB TELEPHONE/DATA CONDUIT TO 6" ABOVE ACCESSIBLE CEILING SPACE. CONNECT TO MODULAR FURNITURE AS REQUIRED. VERIFY EXACT LOCATION AND REQUIREMENTS PRIOR TO INSTALL. PROVIDE POWER POLE WITH SEPARATE POWER AND DATA RACEWAYS. COORDINATE EXACT LOCATION AND REQUIREMENTS. CONNECT TO MODULAR FURNITURE AS REQUIRED. VERIFY EXACT LOCATION AND ADJUST ACCORDINGLY. PROVIDE IN-WALL J-BOXES WITH PROVISIONS FOR WHIP CONNECTIONS TO MODULAR FURNITURE FOR POWER AND DATA. PROVIDE POWER CONNECTION AS SHOWN AND (1) 1-1/4"CO FOR TELEPHONE/DATA. STUB TELEPHONE/DATA CONDUIT TO 6" ABOVE ACCESSIBLE CEILING SPACE. CONNECT TO MODULAR FURNITURE AS REQUIRED. VERIFY EXACT LOCATION AND REQUIREMENTS PRIOR TO INSTALL. PROVIDE J-BOX FOR TRANSFORMER FOR ELECTRONIC FAUCETS. VERIFY LOCATION AND SIZE WITH PLUMBING. PROVIDE 3/4"C WITH LOW VOLTAGE CONDUCTORS FROM ELECTRONIC FAUCETS AS REQUIRED. CONNECT TO FAUCETS AS REQUIRED. PROVIDE JUNCTION BOX FOR TRANSFORMER FOR ELECTRONIC FLUSH VALVES AS REQUIRED. VERIFY EXACT LOCATION AND REQUIREMENTS WITH PLUMBING. PROVIDE 3/4"C WITH LOW VOLTAGE CONDUCTORS FROM FLUSH VALVE TRANSFORMER TO FLUSH VALVES AS REQUIRED. CONNECT TO VAV BOXES AS REQUIRED. CONNECT TO BY-PASS DAMPER SYSTEM TRANSFORMER 120-24V (BY MECHANICAL). ELECTRICAL CONTRACTOR SHALL PROVIDE NEMA "1" ENCLOSURE FOR SYSTEM TRANSFORMER, COORDINATE SIZE WITH MECHANICAL CONTRACTOR. CONNECT TO SMOKE FIRE DAMPER AS REQUIRED. PROVIDE DISCONNECT. CONNECT TO ZONE DAMPER AS REQUIRED. PROVIDE WP J-BOX AND CONNECT TO DUCT SMOKE DETECTOR AS REQUIRED. CONNECT TO ZONEX SYSTEM TRANSFORMER 120-24V (BY MECHANICAL). ELECTRICAL CONTRACTOR SHALL PROVIDE NEMA "1" ENCLOSURE FOR SYSTEM TRANSFORMER, COORDINATE SIZE AND LOCATION WITH MECHANICAL CONTRACTOR. PROVIDE BOX AND CONNECT TO HAND DRYER AS REQUIRED. ELEVATOR SERVICE DISCONNECT. SEE SINGLE LINE DIAGRAM FOR SPECIFICATION. VERIFY EXACT LOCATION AND REQUIREMENTS WITH ELEVATOR CONTRACTOR AND ADJUST ACCORDINGLY. PROVIDE 30A-2P-240V HEAVY DUTY, FUSED DISCONNECT SWITCH WITH 20A FUSES FOR CAB LIGHTS AND HVAC. CONNECT TO ELEVATOR CAB LIGHTS AS REQUIRED. VERIFY EXACT LOCATION AND REQUIREMENTS WITH ELEVATOR CONTRACTOR AND ADJUST ACCORDINGLY. POWER SYMBOL LIST (SOME MAY NOT BE USED) COLD WATER SERVICE INTO BUILDING, VERIFY LOCATION CONDUIT STUB OUT, VERIFY LOCATION CONDUIT RISER UP, VERIFY LOCATION CONDUIT HOMERUN TO PANEL AND BREAKERS INDICATED UNDERGROUND CONDUIT, 3/4" MINIMUM 2#12-1#12G-1/2"C CONDUIT RISER DOWN, VERIFY LOCATION PULL BOX W/ TRAFFIC COVER CW PB TELEPHONE / DATA OUTLET MOUNTED AT 18" AFF DATA OUTLET MOUNTED AT 18" AFF TELEPHONE OUTLET MOUNTED AT 18" AFF CONDUIT RUN CONCEALED IN WALLS OR CEILINGS MGB MAIN GROUND BUS T 2#10-1#10G-1/2"C 2#8-1#8G-3/4"C 3#12-1#12G-1/2"C 3#10-1#10G-3/4"C 3#8-1#8G-1"C 4#12-1#12G-1/2"C 4#10-1#10G-3/4"C 4#8-1#8G-1"C 5#12-1#12G-1/2"C 5#10-1#10G-3/4"C 5#8-1#8G-1 1/4"C 6#12-1#12G-3/4"C 6#10-1#10G-3/4"C 6#8-1#8G-1 1/4"C 2#6-1#6G-3/4"C 3#6-1#6G-1"C 4#6-1#6G-1"C 5#6-1#6G-1 1/4"C 6#6-1#6G-1 1/4"C 4#12 H-2#12N-1#12G-1#12IG-3/4"C POWERED PARTITION FEEDS 4#10H-2#10N-1#10G-1#10IG-1"C 4#8H-2#8N-1#8G-1#8IG-1 1/4"C 4#6H-2#6N-1#6G-1#6IG-1 1/2"C 20A-125V DUPLEX RECEPTACLE MOUNTED AT 18" AFF 20A-125V DOUBLE DUPLEX RECEPTACLE MOUNTED AT 18" AFF SPECIAL USE RECEPTACLE, SEE PLANS FOR SPECIFICATIONS. MOUNT AT 18" AFF OR AS OTHERWISE NOTED. JUNCTION BOX, SIZE PER CODE. DISCONNECT SWITCH, 600V-3P, NEMA 3R, FUSED, HEAVY DUTY, HORSEPOWER RATED, AMP RATING AS REQUIRED. COMBINATION MOTOR STARTER DISCONNECT SWITCH, 600V-3P, NEMA 3R, FUSED, HEAVY DUTY, HORSEPOWER RATED, AMP RATING AND STARTER SIZE AS REQUIRED MOTOR OR EXHAUST FAN THERMOSTAT GENERAL SYMBOL LIST (SOME MAY NOT BE USED) THESE SPECIFICATIONS APPLY UNLESS OTHERWISE NOTED IN THESE DRAWINGS. VERIFY ALL LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECT AND/OR OWNER. SEE PLANS AND LUMINAIRE SCHEDULE FOR LIGHT FIXTURE SYMBOLS. ALL OPERABLE PARTS AND BOXES FOR FUTURE OPERABLE PARTS SHALL BE INSTALLED TO COMPLY WITH CURRENT ADA REQUIREMENTS. SWITCHES, MOUNTED AT 44" AFF, SUBSCRIPT INDICATES CONTROL, ALL LINE VOLTAGE SWITCHES SHALL BE RATED FOR LOAD AT 20A-277V FOR 277V CIRCUITS AND 20A-120V FOR 120V CIRCUITS. $ - SINGLE POLE LIGHT SWITCH S3 - THREE WAY LIGHT SWITCH SP - SINGLE POLE LIGHT SWITCH WITH PILOT LIGHT S4 - FOUR WAY LIGHT SWITCH SK - SINGLE POLE KEYED LIGHT SWITCH SM - MANUAL MOTOR STARTER, HP RATED, NEMA 3R SLV1 - LOW VOLTAGE CONTROL SWITCH J FF BD ZD DSD ZX E H J J FF J J J P D HD J PROVIDE LINE VOLTAGE, DUAL-TECHNOLOGY, WALL SWITCH OCCUPANCY SENSOR. SENSOR SWITCH #WSX-PDT-WH. PROVIDE SENSOR SWITCH nLIGHT ENABLED PHOTO SENSOR WITH BOTH ON/OFF AND AUTOMATIC DIMMING CONTROL FOR DAYLIGHT HARVESTING. SENSOR SWITCH nLIGHT # nCM-ADCX. VERIFY LOCATION PRIOR TO INSTALLATION. PROVIDE SENSOR SWITCH nLIGHT ENABLED PHOTO SENSOR WITH BOTH ON/OFF AND AUTOMATIC DIMMING CONTROL FOR DAYLIGHT HARVESTING. SENSOR SWITCH nLIGHT # nCM-ADCX-DZ (DUAL ZONE). VERIFY LOCATION PRIOR TO INSTALLATION. PROVIDE HIGH MOUNT SENSOR SWITCH nLIGHT ENABLED CEILING MOUNTED, OCCUPANCY SENSOR #NCM-6-RJB FOR APPLICATIONS WHERE MOUNTING IS 15FT TO 45FT. PROVIDE POWER PACKS TO CONTROL LIGHTS AND/OR SWITCHED RECEPTACLES, AS REQUIRED, FOR RECEPTACLES. PROVIDE SENSOR SWITCH NLIGHT # nPP20-PL FOR EACH SWITCHED RECEPTACLE CIRCUIT. VERIFY LOCATION PRIOR TO INSTALLATION. PROVIDE SMALL MOTION SENSOR SWITCH nLIGHT ENABLED CEILING MOUNTED, DUAL-TECHNOLOGY OCCUPANCY SENSOR WITH INTERNAL AUTOMATIC DIMMING CONTROL PHOTOCELL AND LOW VOLTAGE AUXILIARY RELAY. SENSOR SWITCH nLIGHT #nCM-PDT-9-ADCX-RJB-AR (OR ADC FOR 0-10V SYSTEMS AS APPLICABLE). ENABLE AUTOMATIC DIMMING CONTROL WHERE DAYLIGHT HARVESTING IS REQUIRED AND DISABLE IT IF SENSOR IS OUTSIDE OF DAYLIT AREA. PROVIDE POWER PACKS TO CONTROL LIGHTS AND/OR SWITCHED RECEPTACLES, AS REQUIRED, FOR RECEPTACLES. PROVIDE SENSOR SWITCH nLIGHT # nPP20-PL FOR EACH SWITCHED RECEPTACLE CIRCUIT. VERIFY LOCATION PRIOR TO INSTALLATION. PROVIDE LARGE MOTION SENSOR SWITCH nLIGHT ENABLED CEILING MOUNTED, DUAL-TECHNOLOGY OCCUPANCY SENSOR WITH INTERNAL AUTOMATIC DIMMING CONTROL PHOTOCELL AND LOW VOLTAGE AUXILIARY RELAY. SENSOR SWITCH nLIGHT #nCM-PDT-10-ADCX-RJB-AR (OR ADC FOR 0-10V SYSTEMS AS APPLICABLE). ENABLE AUTOMATIC DIMMING CONTROL WHERE DAYLIGHT HARVESTING IS REQUIRED AND DISABLE IT IF SENSOR IS OUTSIDE OF DAYLIT AREA.PROVIDE POWER PACKS TO CONTROL LIGHTS AND/OR SWITCHED RECEPTACLES, AS REQUIRED, FOR RECEPTACLES. PROVIDE SENSOR SWITCH nLIGHT # nPP20-PL FOR EACH SWITCHED RECEPTACLE CIRCUIT. VERIFY LOCATION PRIOR TO INSTALLATION. PROVIDE SENSOR SWITCH nLIGHT ENABLED, DUAL-TECHNOLOGY, WALL SWITCH OCCUPANCY SENSOR WITH DIMMING CONTROL. SENSOR SWITCH nLIGHT # nWSX-PDT-LV-DX-WH. PROVIDE nAR40 AUXILIARY RELAY FOR HVAC ZONE CONTROL AS REQUIRED. PROVIDE SENSOR SWITCH nLIGHT ENABLED WALL POD WITH SINGLE CHANNEL, ON/OFF AND RAISE LOWER CONTROL. SENSOR SWITCH nLIGHT # nPODMA-DX-WH. VERIFY LOCATION PRIOR TO INSTALLATION. PROVIDE SENSOR SWITCH nLIGHT ENABLED WALL POD WITH 2-CHANNELS, ON/OFF AND RAISE LOWER CONTROL. SENSOR SWITCH nLIGHT # nPODMA-2P-DX-WH. PROVIDE SEPARATE POWER PACK FOR EACH CHANNEL. VERIFY LOCATION PRIOR TO INSTALLATION. PROVIDE SENSOR SWITCH nLIGHT ENABLED WALL POD WITH 4-CHANNELS, ON/OFF AND RAISE LOWER CONTROL. SENSOR SWITCH nLIGHT # nPODMA-4P-DX-WH. PROVIDE SEPARATE POWER PACK FOR EACH CHANNEL. VERIFY LOCATION PRIOR TO INSTALLATION. PROVIDE SENSOR SWITCH NLIGHT ENABLED CORNER WALL MOUNTED, DUAL-TECHNOLOGY OCCUPANCY SENSOR. SENSOR SWITCH NLIGHT #nWV-PDT-16. PROVIDE POWER PACKS TO CONTROL LIGHTS AS REQUIRED. PROVIDE nAR40 AUXILIARY RELAY FOR HVAC ZONE CONTROL AS REQUIRED. PROVIDE SENSOR SWITCH nLIGHT DIMMING MODULE #0-10V DIMMING nPP16-D, MOUNT ABOVE ACCESSIBLE CEILING PER MANUFACTURER'S REQUIREMENTS. PROVIDE ONE MODULE FOR EACH CONTROL ZONE WITHIN EACH ROOM OR CORRIDOR AS INDICATED BY LOWER CASE LETTER. CONNECT TO MODULAR WIRING SYSTEM OR ROOM LIGHTING CIRCUIT AS REQUIRED. PROVIDE UL924 LISTED SENSOR SWITCH nLIGHT DIMMING MODULE #0-10V DIMMING nPP16D-ER, MOUNT ABOVE ACCESSIBLE CEILING PER MANUFACTURER'S REQUIREMENTS. PROVIDE ONE MODULE PER ZONE. CONNECT DIMMING MODULE TO NEAREST (CONSTANT HOT) UNSWITCHED CIRCUIT AS REQUIRED. CONNECT TO MODULAR WIRING SYSTEM OR ROOM LIGHTING CIRCUIT AS REQUIRED. PROVIDE J BOX AND CONNECT TO MODULAR WIRING SYSTEM AS REQUIRED. INDICATES APPLICABLE LIGHTING CONTROL DIAGRAM. SEE LIGHTING CONTROL DIAGRAMS THESE DRAWINGS. LIGHTING SYMBOL LIST (SOME MAY NOT BE USED) P1 P2 J J J XX S0 6 9 10 S1 S2 S4 GENERAL LABELING AND MARKING NOTES (UNLESS OTHERWISE NOTED, SOME MAY NOT APPLY) A.PER 110.21, WHERE CAUTION, WARNING, OR DANGER SIGNS OR LABELS ARE REQUIRED BY CODE, THE LABELS SHALL MEET THE FOLLOWING REQUIREMENTS: (1)THE MARKING SHALL WARN OF THE HAZARDS USING EFFECTIVE WORDS, COLORS, SYMBOLS, OR ANY COMBINATION THEREOF. (2)THE LABEL SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN. EXCEPTION TO (2): PORTIONS OF LABELS OR MARKINGS THAT ARE VARIABLE, OR THAT COULD BE SUBJECT TO CHANGES, SHALL BE PERMITTED TO BE HANDWRITTEN AND SHALL BE LEGIBLE. (3)THE LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. (4)THE LABEL SHALL BE LOCATED SO AS TO BE CLEARLY VISIBLE TO QUALIFIED PERSONS BEFORE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE OF THE EQUIPMENT. (5)COORDINATE WITH OWNER FOR BUILDING STANDARDS. ALL LABELS SHALL COMPLY WITH APPLICABLE CODES. B.PER 110.16(A), ELECTRICAL EQUIPMENT, SUCH AS SWITCHBOARDS, SWITCHGEAR, PANELBOARDS, INDUSTRIAL CONTROL PANELS, METER SOCKET ENCLOSURES, AND MOTOR CONTROL CENTERS, THAT IS IN OTHER THAN DWELLING UNITS, AND IS LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE WHILE ENERGIZED, SHALL BE FIELD OR FACTORY MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS. C.PER 110.16(B), IN OTHER THAN DWELLING UNITS, IN ADDITION TO THE REQUIREMENTS IN 110.16(A), A PERMANENT LABEL SHALL BE FIELD OR FACTORY APPLIED TO SERVICE EQUIPMENT RATED 1200 AMPS OR MORE. THE LABEL SHALL MEET THE REQUIREMENTS OF 110.21(B) AND CONTAIN THE FOLLOWING INFORMATION: (1)NOMINAL SYSTEM VOLTAGE (2)AVAILABLE FAULT CURRENT AT THE SERVICE OVERCURRENT PROTECTIVE DEVICES (3)THE CLEARING TIME OF SERVICE OVERCURRENT PROTECTIVE DEVICES BASED ON THE AVAILABLE FAULT CURRENT AT THE SERVICE EQUIPMENT (4)THE DATE THE LABEL WAS APPLIED D.PER 110.22(A), EACH DISCONNECTING MEANS SHALL BE LEGIBLY MARKED TO INDICATE ITS PURPOSE UNLESS LOCATED AND ARRANGED SO THE PURPOSE IS EVIDENT. IN OTHER THAN ONE- OR TWO-FAMILY DWELLINGS, THE MARKING SHALL INCLUDE THE IDENTIFICATION OF THE CIRCUIT SOURCE THAT SUPPLIES THE DISCONNECTING MEANS. E.PER 110.22(C), EQUIPMENT ENCLOSURES FOR CIRCUIT BREAKERS OR FUSES APPLIED IN COMPLIANCE WITH THE SERIES COMBINATION RATINGS MARKED ON THE EQUIPMENT BY THE MANUFACTURER IN ACCORDANCE WITH 240.86(B) SHALL BE LEGIBLY MARKED IN THE FIELD TO INDICATE THE EQUIPMENT HAS BEEN APPLIED WITH A SERIES COMBINATION RATING. THE MARKING SHALL MEET THE REQUIREMENTS IN 110.21(B) AND SHALL BE READILY VISIBLE AND STATE THE FOLLOWING: CAUTION — SERIES COMBINATION SYSTEM RATED ____ AMPERES. IDENTIFIED REPLACEMENT COMPONENTS REQUIRED. F.PER 110.24, SERVICE EQUIPMENT AT OTHER THAN DWELLING UNITS SHALL BE LEGIBLY MARKED IN THE FIELD WITH THE AVAILABLE FAULT CURRENT. THE FIELD MARKING(S) SHALL INCLUDE THE DATE THE FAULT-CURRENT CALCULATION WAS PERFORMED AND BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. THE CALCULATION SHALL BE DOCUMENTED AND MADE AVAILABLE TO THOSE AUTHORIZED TO DESIGN, INSTALL, INSPECT, MAINTAIN, OR OPERATE THE SYSTEM. THE EQUIPMENT SHORT CIRCUIT CURRENT RATING SHALL NOT BE LESS THAN THE AVAILABLE FAULT CURRENT. G.PER 210.5, THE METHOD UTILIZED FOR CONDUCTORS ORIGINATING WITHIN EACH BRANCH-CIRCUIT PANELBOARD OR SIMILAR BRANCH-CIRCUIT DISTRIBUTION EQUIPMENT SHALL BE DOCUMENTED IN A MANNER THAT IS READILY AVAILABLE OR SHALL BE PERMANENTLY POSTED AT EACH BRANCH-CIRCUIT PANELBOARD OR SIMILAR BRANCH-CIRCUIT DISTRIBUTION EQUIPMENT. THE LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE HANDWRITTEN. CONDUCTORS AND CABLES SHALL BE COLOR CODED BY THE MANUFACTURER AT THE FACTORY FOR THE ENTIRE LENGTH. WRAPPING COLOR TAPES ARE NOT PERMITTED. COLOR CODING SHALL BE AS FOLLOWS: 120/208V SYSTEM 277/480V SYSTEMS PHASE A:BLACK BROWN PHASE B:RED ORANGE PHASE C:BLUE YELLOW NEUTRAL:WHITE GREY GROUND:GREEN GREEN ISOLATED GROUND:GREEN/YELLOW STRIPE GREEN/YELLOW STRIPE WHERE DEDICATED NEUTRALS ARE PROVIDED, USE COLOR SPIRAL TO MATCH ASSOCIATED PHASE. H.PER 408.4(A), EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC PURPOSE OR USE. THE IDENTIFICATION SHALL INCLUDE AN APPROVED DEGREE OF DETAIL THAT ALLOWS EACH CIRCUIT TO BE DISTINGUISHED FROM ALL OTHERS. SPARE POSITIONS THAT CONTAIN UNUSED OVERCURRENT DEVICES OR SWITCHES SHALL BE DESCRI⁠BED ACCORDINGLY. THE IDENTIFICATION SHALL BE INCLUDED IN A CIRCUIT DIRECTORY THAT IS LOCATED ON THE FACE, INSIDE OF, OR IN AN APPROVED LOCATION ADJACENT TO THE PANEL DOOR IN THE CASE OF A PANELBOARD AND AT EACH SWITCH OR CIRCUIT BREAKER IN A SWITCHBOARD OR SWITCHGEAR. NO CIRCUIT SHALL BE DESCRIBED IN A MANNER THAT DEPENDS ON TRANSIENT CONDITIONS OF OCCUPANCY. ALL NEW AND MODIFIED PANEL CARDS SHALL BE TYPED AND SHALL INCLUDE DATE. RECREATE PANEL CARDS FOR ANY PANELS THAT ARE MODIFIED. I.PER 408.4(B), ALL NEW AND MODIFIED SWITCHBOARDS, SWITCHGEAR, AND PANELBOARDS SUPPLIED BY A FEEDER(S) IN OTHER THAN ONE- OR TWO-FAMILY DWELLINGS SHALL BE PERMANENTLY MARKED TO INDICATE EACH DEVICE OR EQUIPMENT WHERE THE POWER ORIGINATES. THE LABEL SHALL INCLUDE PANEL NAME AND FEEDER RATING WITH AMPS-VOLTS-PHASES-WIRES. J.PER 450.14, WHERE A TRANSFORMER IS NOT WITHIN SIGHT OF ITS SUPPLY SIDE DISCONNECT, PROVIDE A PERMANENT PLACARD ON THE TRANSFORMER INDICATING THE LOCATION OF THE SUPPLY SIDE DISCONNECTING MEANS. THE SUPPLY SIDE DISCONNECT SHALL BE LOCKABLE IN THE OPEN POSITION. K.PROVIDE ALL OTHER LABELING REQUIRED BY CODE. L.ALL LABELS AND MARKINGS SHALL BE TYPEWRITTEN. M.ALL LABELS AND PLACARDS SHALL MEET BUILDING STANDARDS. GENERAL NOTES A.PRIOR TO BID, CONTRACTOR SHALL WALK THE SITE AND SHALL BE THOROUGHLY FAMILIAR WITH THE CONDITIONS AND SHALL INCLUDE IN HIS BID ALL NECESSARY CONDUIT, CONDUCTORS, SUPPORTS, ETC., WHETHER SHOWN ON THESE DRAWINGS OR NOT, NECESSARY TO PROVIDE A COMPLETE OPERABLE SYSTEM THAT MEETS THE DESIGN INTENT AND EDWARDS REQUIREMENTS. B.PRIOR TO START OF WORK, CONTRACTOR SHALL NOTIFY EDWARDS AND ENGINEER OF ANY FIELD CONDITIONS THAT MAY PREVENT MEETING THE DESIGN INTENT. C.CONTRACTOR SHALL VERIFY ALL LOCATIONS, CONDUIT ROUTING, AND OTHER REQUIREMENTS PRIOR TO INSTALLATION. D.CONTRACTOR SHALL COORDINATE THE MOUNTING OF ALL CONDUIT AND OTHER EQUIPMENT WITH STRUCTURAL AND EDWARDS PRIOR TO INSTALLATION. CONTRACTOR SHALL ACQUIRE AND REVIEW ALL STRUCTURAL DRAWINGS RELATED TO THIS PROJECT PRIOR TO BID AND SHALL INCLUDE ALL REQUIREMENTS IN HIS BID. E.CONDUIT SHALL BE ROUTED BELOW THE ROOF WHERE FEASIBLE. F.ALL CONDUIT ROUTED ON THE ROOF SHALL BE SUPPORTED WITH DURA-BLOK SUPPORTS, OR AS DIRECTED BY EDWARDS, AT CODE REQUIRED INTERVALS. G.PRIOR TO INSTALLATION OF ANY CONDUIT OR EQUIPMENT, CONTRACTOR SHALL DEMONSTRATE TO EDWARDS THE EXACT CONDUIT ROUTING AND LUMINAIRE LOCATIONS VIA A NON-PERMANENT MEANS. H.CONTRACTOR SHALL COORDINATE THE MOUNTING OF ALL EQUIPMENT WITH STRUCTURAL PRIOR TO INSTALLATION. I.CONTRACTOR SHALL NOT PENETRATE THE ROOF UNLESS PREVIOUSLY APPROVED BY EDWARDS, STRUCTURAL AND ROOF CONTRACTOR. J.ALL ROOF PENETRATIONS SHALL BE APPROVED BY EDWARDS AND ROOF CONTRACTOR PRIOR TO INSTALLATION. ALL ROOF PENETRATIONS SHALL INCLUDE A ROOF JACK AND SHALL BE WEATHERPROOFED PER THE ROOFING CONTRACTOR. K.ALL CONDUITS ON ROOF SHALL BE PAINTED TO MATCH EXISTING OR AS DIRECTED BY EDWARDS. CONDUITS THAT CROSS WALKING PATH SHALL BE PAINTED SAFETY YELLOW OR AS DIRECTED BY OWNER. L.ALL CONDUITS SUBJECT TO PHYSICAL DAMAGE SHALL BE IMC MINIMUM, OR AS DIRECTED BY EDWARDS. M.COORDINATE OF ALL LOCATIONS WITH MECHANICAL AND ADJUST AS NECESSARY. N.PROVIDE CONTROLS CONDUITS AS DIRECTED BY MECHANICAL. O.ALL CONDUIT CONNECTORS SHALL BE COMPRESSION TYPE. REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 23 2 7 6 S O U T H P O I N T E D R . , U N I T 1 0 2 , LA G U N A H I L L S , C A 9 2 6 5 3 O: 9 4 9 - 4 1 9 - 9 9 0 8 F : 9 4 9 - 4 1 9 - 9 8 7 0 E0.2 GENERAL NOTES AND SYMBOLS 3009 S Daimler St 11/18/2024 (E) GENERATOR 213T & 215T 213T & 215T 254T & 256T 254T & 256T 9 1 2 3 4 5 8 6 7 9.1 10 B C D EA OVERALL KEY PLAN SCALE: 1"=10'-0"_XREFA KEYNOTES 1.EXISTING CONCRETE WALL. COORDINATE CONDUIT PENETRATIONS WITH STRUCTURAL AND ADJUST AS NECESSARY. COORDINATE CONDUIT ROUTING WITH EDWARDS PRIOR TO INSTALL. # SEE SPECIFICATIONS, GENERAL NOTES, SYMBOLS, AND ASSOCIATED REQUIREMENTS. CONTRACTOR SHALL THOROUGHLY REVIEW ALL SPECIFICATIONS, NOTES AND SYMBOLS AND INCLUDE ALL REQUIREMENTS IN HIS BID. VERIFY ALL LOCATIONS AND REQUIREMENTS PRIOR TO INSTALL. REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 23 2 7 6 S O U T H P O I N T E D R . , U N I T 1 0 2 , LA G U N A H I L L S , C A 9 2 6 5 3 O: 9 4 9 - 4 1 9 - 9 9 0 8 F : 9 4 9 - 4 1 9 - 9 8 7 0 E1.1 OVERALL KEY PLAN A E4.1 A E4.2 (E) MSA (E) EHL1 SCOPE OF WORK A E4.5 (E) LCP-HL1 (E) HL1 T-DBL2 DBL2 HM3 1 TYP 1L21 1L22 1 1 3009 S Daimler St 11/18/2024 KEYNOTES 1.EXISTING CIRCUIT BREAKER AND METERING SYSTEM. CONNECT NEW FEEDER AS REQUIRED. ADJUST TRIP UNIT AS INDICTED. EXISTING CIRCUIT BREAKER IS TEMPORARILY LABELED "CRWH". RE-LABEL CIRCUIT BREAKER AND METER "T-DBL2". LABELING SHALL MATCH EXISTING PERMANENT LABELING. 2.EXISTING CIRCUIT BREAKER AND METERING SYSTEM. CONNECT NEW FEEDER AS REQUIRED. ADJUST TRIP UNIT AS INDICTED. EXISTING CIRCUIT BREAKER IS TEMPORARILY LABELED "CRWM". RE-LABEL CIRCUIT BREAKER AND METER "HM3". LABELING SHALL MATCH EXISTING PERMANENT LABELING. 3.PROVIDE 225A-120/208V-3PH-4W OVERHEAD PLUG-IN BUSWAY. SEE KEYNOTE 1 ON E4.1 FOR SPECIFICATION. 4.PROVIDE 500A-120/208V-3PH-4W OVERHEAD PLUG-IN BUSWAY. SEE KEYNOTE 2 ON E4.1 FOR SPECIFICATION. 5.PROVIDE WITH PLATED COPPER BUSSING TO MATCH EXISTING. PROVIDE ALTERNATE DEDUCT IN BID TO PROVIDE ALUMINUM BUSSING. EQUIPMENT SHALL FIT IN ALLOTTED SPACE WITH CODE REQUIRED CLEARANCES. 6.PROVIDE ALTERNATE DEDUCT IN BID TO PROVIDE ALUMINUM WINDINGS. EQUIPMENT SHALL FIT IN ALLOTTED SPACE WITH CODE REQUIRED CLEARANCES. 7.PROVIDE NEW SCHEIDER ELECTRIC PM5000 METERING SYSTEM. PROVIDE 3/4"C AND NETWORK CABLING TO EXISTING METERING NETWORK UNDER BAS CONTROLLERS AS DIRECTED BY EDWARDS CONTROLS CONTRACTOR. PROVIDE ALL CONDUIT, CONDUCTORS, EQUIPMENT, LABOR, TESTING, PROGRAMMING, FACTORY START UP, ETC. NECESSARY TO INTEGRATE THE NEW METER INTO THE EXISTING SYSTEM. VERIFY IN FIELD. 8.NOT USED. 9.NOT USED. 10.PANEL SHALL BE 65KAIC FULLY RATED MINIMUM. 11.PANEL SHALL BE 35KAIC FULLY RATED MINIMUM. (UNLESS OTHERWISE NOTED, SOME NOTES MAY NOT APPLY) A.THE FEEDER LENGTHS SHOWN ARE ESTIMATED FOR VOLTAGE DROP CALCULATIONS ONLY. CONTRACTOR SHALL NOT USE THE LENGTHS FOR BIDDING OR ORDERING PURPOSES. B.SIZE NO. 1 AWG CONDUCTORS AND SMALLER ARE TO USE THE 60 DEG C COLUMN OF TABLE 310.16 TO DETERMINE AMPACITY. CONDUCTORS #1/0 AWG AND LARGER ARE TO USE THE 75 DEG C COLUMN OF TABLE 310.16 TO DETERMINE AMPACITY. (SEE UL ELECTRICAL CONSTRUCTION MATERIALS DIRECTORY AND ART 110.14(C). C.ALL CONDUCTORS SHALL BE COPPER AND RATED 90 DEGREE C AND 600 VOLTS UNLESS OTHERWISE NOTED. SIZES NO. 8 AWG AND LARGER SHALL BE STRANDED AND NO. 10 AND SMALLER SHALL BE SOLID. USE TYPE THHN, THWN-2. D.ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION AND PER THE LOCAL AUTHORITY HAVING JURISDICTION. E.ALL EQUIPMENT SHALL BE INSTALLED PER ITS LISTING. MAINTAIN ALL EQUIPMENT CLEARANCES SHALL BE PER CODE. F.ELECTRICAL DRAWINGS AND SINGLE LINE ARE DIAGRAMMATIC IN NATURE. EQUIPMENT SHALL BE LAID OUT PER CORRESPONDING PLAN ON THIS DRAWING. G.ALL CIRCUIT BREAKERS SHALL BE BOLT ON TYPE. H.ALL FUSES SHALL BE CLASS "R" LPN-RK (250V) OR LPS-RK (600V), UNLESS OTHERWISE NOTED. I.CONTRACTOR SHALL ENSURE ALL CIRCUIT BREAKER AND PANELBOARD TERMINAL LUGS ARE RATED FOR THE CONDUCTOR SIZE AND QUANTITY SHOWN ON THE SINGLE LINE DIAGRAM AND ASSOCIATED FEEDER SCHEDULE. J.ALL CIRCUIT BREAKER AND PANELBOARD TERMINAL LUGS SHALL BE RATED FOR 75 DEG C AND FOR THE CONDUCTOR MATERIAL AND SIZE SPECIFIED ON THE SINGLE LINE DIAGRAM AND ASSOCIATED FEEDER SCHEDULE. K.ELECTRICAL EQUIPMENT SHALL FIT IN ALLOTTED SPACE WITH CODE AND MANUFACTURER'SREQUIRED CLEARANCES. L.CONTRACTOR SHALL INCLUDE IN HIS BID THE COSTS OF ALL CONDUCTOR PULLING CALCULATIONS AS REQUIRED. M.CONTRACTOR SHALL INCLUDE ALL NECESSARY PULL BOXES OR SPLICE BOXES AS REQUIRED TO MEET THE INTENT OF DESIGN. N.CONTRACTOR SHALL COORDINATE ALL CONDUIT ROUTING AND ELECTRICAL EQUIPMENT LOCATIONS WITH ARCHITECT, OWNER, TENANT AND OTHER TRADES. O.CONTRACTOR SHALL CONSULT WITH AND COORDINATE WITH STRUCTURAL ENGINEER FOR ALL CONDUIT OR ELECTRICAL EQUIPMENT MOUNTED TO OR SUSPENDED FROM CEILINGS, ROOF STRUCTURES, WALLS OR OTHER BUILDING ELEMENTS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE STRUCTURAL ENGINEER WITH WEIGHTS, SIZES, MOUNTING POINTS AND ALL OTHER DATA NECESSARY FOR THE STRUCTURAL ENGINEER TO COMPLETE HIS ANALYSIS. WHERE NECESSARY, THE CONTRACTOR SHALL INCLUDE IN HIS BID A LINE ITEM COST TO HIRE A STRUCTURAL ENGINEER LICENSED IN THE STATE OF THE PROJECT, TO CONDUCT THE REQUIRED ENGINEERING. P.CONTRACTOR SHALL VERIFY ALL LOCATIONS, MOUNTING HEIGHTS, CONNECTIONS AND REQUIREMENTS WITH OTHER TRADES, OWNER, ARCHITECT AND/OR TENANT AS APPLICABLE PRIOR TO INSTALL AND ADJUST ACCORDINGLY. CONTRACTOR SHALL REVIEW ALL OTHER TRADE'S DRAWINGS AND INCLUDE IN HIS BID ALL COSTS APPLICABLE TO THE ELECTRICAL TRADE WHETHER SHOWN IN THESE DRAWINGS OR NOT. GENERAL SINGLE LINE DIAGRAM NOTES FEEDER SCHEDULE SOME MAY NOT BE USED MARK a SETS b PHASE c NEUTRAL d GROUND e CONDUIT f 20G 1 3#12 1#12 1/2" 20NG 1 3#12 1#12 1#12 1/2" 30G 1 3#10 1#10 3/4" 30NG 1 3#10 1#10 1#10 3/4" 40G 1 3#8 1#10 3/4" 40NG 1 3#8 1#8 1#10 1" 50G 1 3#6 1#10 1-1/4" 50NG 1 3#6 1#6 1#10 1-1/4" 70G 1 3#4 1#8 1-1/4" 70NG 1 3#4 1#4 1#8 1-1/4" 100G 1 3#1 1#8 1-1/2" 100NG 1 3#1 1#1 1#8 1-1/2" 125G 1 3#1/0 1#6 2" 125NG 1 3#1/0 1#1/0 1#6 2" 150G 1 3#1/0 1#6 2" 150NG 1 3#1/0 1#1/0 1#6 2" 175G 1 3#2/0 1#6 2" 175NG 1 3#2/0 1#2/0 1#6 2" 200G 1 3#3/0 1#6 2" 200NG 1 3#3/0 1#3/0 1#6 2-1/2" 225G 1 3#4/0 1#4 2-1/2" 225NG 1 3#4/0 1#4/0 1#4 2-1/2" 250NG 1 3#250 1#250 1#4 2-1/2" 350G 2 3#2/0 1#3 2" 350NG 2 3#2/0 1#2/0 1#3 2" 400G 1 3#500 1#3 4" 400NG 1 3#500 1#500 1#3 4" 450G 2 3#4/0 1#2 2-1/2" 500G 2 3#250 1#2 2-1/2" 500NG 2 3#250 1#250 1#2 2-1/2" 600G 2 3#350 1#1 3" 600NG 2 3#350 1#350 1#1 3" 750G 2 3#500 1#1/0 4" 800G 2 3#500 1#1/0 4" 800NG 2 3#500 1#500 1#1/0 4" TRANSFORMER SECONDARY FEEDERS T300NG 4 3#300 1#300 1#3/0 3" T500NG 4 3#600 1#600 1#300 4" FEEDER SCHEDULE NOTES: a.MARK DEFINITIONS: NUMBER INDICATES OVERCURRENT DEVICE TRIP RATING "N" INDICATES PROVIDE NEUTRAL CONDUCTOR "G" INDICATES PROVIDE EQUIPMENT GROUNDING CONDUCTOR "IG" INDICATES PROVIDE ISOLATED GROUND CONDUCTOR "VD" INDICATES FEEDER HAS BEEN ADJUSTED FOR VOLTAGE DROP "T" INDICATES TRANSFORMER SECONDARY FEEDER, THE NUMBER INDICATES THE APPROXIMATE SIZE OF THE TRANSFORMER IN KVA. b.SETS INDICATES NUMBER OF PARALLEL SET OF CONDUITS AND CONDUCTORS. EACH PARALLEL CONDUIT SHALL INCLUDE ALL PHASE, NEUTRAL AND GROUND CONDUCTORS INDICATED. COMPLY WITH ART 310.10(H). c.PHASE INDICATES THE MINIMUM SIZE AND QUANTITY OF UNGROUNDED (PHASE) CONDUCTORS IN EACH RACEWAY. d.NEUTRAL INDICATES THE MINIMUM SIZE AND QUANTITY OF GROUNDED (NEUTRAL) CONDUCTORS IN EACH RACEWAY. e.GROUND INDICATES THE MINIMUM SIZE AND QUANTITY OF EQUIPMENT GROUND CONDUCTORS IN EACH RACEWAY. WHERE NUMBER OF EQUIPMENT GROUNDS ARE 2, ONE SHALL BE AN ISOLATED GROUND, UNLESS OTHERWISE NOTED f.CONDUIT INDICATES THE MINIMUM SIZE CONDUIT. CONTRACTOR SHALL VERIFY ALL CONDUIT FILLS PRIOR TO INSTALLATION. MINIMUM UNDERGROUND CONDUIT SIZE SHALL BE 3/4". CONTRACTOR MAY INCREASE CONDUIT SIZES. g.FEEDER SCHEDULE IS BASED ON CONDUCTOR TYPES: THHN OR THWN-2 IN ELECTRICAL METALLIC TUBING, FLEXIBLE METALLIC CONDUIT, INTERMEDIATE METALLIC CONDUIT, LIQUID TIGHT FLEXIBLE METAL CONDUIT, RIGID METAL CONDUIT OR SCHEDULE 40 PVC CONDUIT ONLY. CONTRACTOR SHALL ADJUST CONDUIT SIZE FOR DIFFERENT CONDUCTOR OR CONDUIT TYPES PER CODE. h.ALL CONDUCTORS SHALL BE COPPER, RATED 90 DEGREE C,D AND 600 VOLTS MINIMUM. i.GROUND CONDUCTOR ON SEPARATELY DERIVED SYSTEMS SHALL BE SIZED BASED ON 250.102. TRANSFORMER SCHEDULE NOTES: a.FOR EACH TRANSFORMER, PROVIDE A GROUNDING ELECTRODE CONDUCTOR SIZED AS INDICATED ABOVE. BOND TO BUILDING GROUNDING ELECTRODE SYSTEM PER 250.30(A)(4). WHERE A COMMON GROUNDING ELECTRODE CONDUCTOR IS USED FOR MULTIPLE SEPARATELY DERIVED SYSTEMS, THE CONDUCTOR SHALL COMPLY WITH 250.30(A)(6). WHERE THE COMMON GROUNDING ELECTRODE CONDUCTOR IS OF THE WIRE TYPE, IT SHALL NOT BE SMALLER THAN 3/0 AWG AND SHALL BE INCREASED IN SIZE TO ACCOUNT FOR VOLTAGE DROP WHERE NECESSARY. WHERE THE COMMON GROUNDING ELECTRODE CONDUCTOR IS THE METAL STRUCTURAL FRAME OF THE BUILDING, IT SHALL COMPLY WITH 250.68(C)(2) AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING THE CONSTRUCTION OF THE METAL STRUCTURAL FRAME AND THE COMPLIANCE WITH ALL APPLICABLE CODES. THE CONNECTION OF THE GROUNDING ELECTRODE CONDUCTOR AND ASSOCIATED BONDING JUMPER(S) SHALL BE MADE AS SPECIFIED IN 250.68(A) THROUGH (C). IN ADDITION, METAL WATER PIPING SYSTEMS AND STRUCTURAL METAL THAT IS INTERCONNECTED TO FORM A BUILDING FRAME SHALL BE BONDED TO SEPARATELY DERIVED SYSTEMS PER 250.104(D)(1) THROUGH 250.104(D)(3). THE BONDING JUMPER SHALL BE SIZED PER CODE. b.GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED BASED ON TABLE 250.66. c.MAXIMUM SECONDARY FAULT CURRENT IS BASED ON INFINITE BUS CALCULATION WITH MINIMUM IMPEDANCE SHOWN. d.SOME TRANSFORMERS MAY NOT BE USED. DRY-TYPE TRANSFORMER SCHEDULE ALL TRANSFORMERS ARE Δ-Y 480V-120/208V-3 -4W UNLESS OTHERWISE NOTED d MARK RATING (KVA)GROUNDING ELECTRODE CONDUCTOR a,b MINIMUM IMPEDANCE MAXIMUM SECONDARY FAULT CURRENT c COMMENTS T300 300 1#3/0 - 3/4"C 4.5%18.5KA T500 500 1#3/0 - 3/4"C 4.5%30.9KA # SEE SPECIFICATIONS, GENERAL NOTES, SYMBOLS, AND ASSOCIATED REQUIREMENTS. CONTRACTOR SHALL THOROUGHLY REVIEW ALL SPECIFICATIONS, NOTES AND SYMBOLS AND INCLUDE ALL REQUIREMENTS IN HIS BID. VERIFY ALL LOCATIONS AND REQUIREMENTS PRIOR TO INSTALL. GENERAL DRY-TYPE TRANSFORMER GENERAL NOTES A.LOW VOLTAGE DRY-TYPE TRANSFORMERS SHALL BE CERTIFIED BY THE MANUFACTURER AS REQUIRED BY TITLE 20 APPLIANCE EFFICIENCY REGULATIONS PER CALIFORNIA ENERGY CODE 110.11. B.ALL TRANSFORMERS SHALL BE COMPLETELY ENCLOSED EXCEPT FOR VENTILATING OPENINGS. C.TRANSFORMERS RATED OVER 112.5KVA SHALL HAVE CLASS 155 OR HIGHER INSULATION SYSTEMS AND COMPLETELY ENCLOSED EXCEPT FOR VENTILATING OPENINGS. D.PRIMARY DISCONNECT NOT LOCATED WITHIN SIGHT OF TRANSFORMER MUST HAVE LOCKING MEANS AT REMOTE DISCONNECT OR CIRCUIT BREAKER AND A LABEL AT TRANSFORMER DENOTING DISCONNECT LOCATION PER CEC 450.14. E.TRANSFORMERS MUST BE GROUNDED TO THE SAME GROUNDING ELECTRODE SYSTEM OF THE BUILDING PER CEC 250.30(A)(4) AND BONDED PER CEC 250.104(D). SEE GENERAL LABELING AND MARKING NOTES ON SHEET E0.2 REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 23 2 7 6 S O U T H P O I N T E D R . , U N I T 1 0 2 , LA G U N A H I L L S , C A 9 2 6 5 3 O: 9 4 9 - 4 1 9 - 9 9 0 8 F : 9 4 9 - 4 1 9 - 9 8 7 0 E2.1 PARTIAL SINGLE LINE DIAGRAM PARTIAL SINGLE LINE DIAGRAM SCALE: NONE 200/3 (E) FEEDER (E) PANEL HL1 4000A BUS - 100KAIC (E) MAIN SWITCHBOARD MSA 4000A-277/480V-3Ø-4W 100KAIC 4000/3 ALSIG GFPE GND BUS M MGB (E) 4000A PULL SECTION TO UTILITY CO TRANSFORMER (E) 800AF 750AT (E) (E) PANEL HL2 (E) 225AF 225AT (E) FEEDER 50/3 (E) FEEDER (E) FEEDER (E) PANEL EHL1 (E) PANEL EHL2 (E) FEEDER (E) 225AF 225AT (E) 600AF 450AT FROM (E) BACKUP POWER DIST BOARD BKDB1 (E) ATS-E1 50A/4P NEMA 3R SCOPE OF WORK SCOPE OF WORK ALL EQUIPMENT IS NEW UNLESS OTHERWISE INDICATED. NEW EQUIPMENT IS SHOWN BOLD, EXISTING EQUIPMENT IS SHOWN SHADED. CONTRACTOR SHALL FIELD VERIFY PRIOR TO BID. XFMR T-DBL2 (T500) COPPER WOUND 80 DEG C RISE T500NG ±5', NO VD 750G ±180', 0.6% VD 1600AF 1600AT [PDG6M] 250/3 [PDG3F] 250NG ±30', 0.3% VD PANEL 1L21 [QO-VH] 225/3 [PDG2F] 225/3 [PDG2F] 225/3 [PDG2F] 500/3 [PDG3F] 500NG ±60', 0.6% VD 225NG ±100', 1.1% VD 225NG ±80', 0.8% VD 225NG ±60', 0.6% VD PBW1 PBW2 PBW3 PBW4 DISTRIBUTION BOARD DBL2 1600A-120/208V-3Ø-4W 35KAIC MIN 225NG ±180', 0.8% VD PANEL HM3 [EJB] 250/3 [PDG3F] 250NG ±30', 0.3% VD PANEL 1L22 [QO-VH] M MMMMMM 1 7 3 3 3 4 SPD 5 5 5 5 6 2 10 11 11 INDICATES EATON CIRCUIT BREAKER TYPE, TYP. INDICATES AVAILABLE FAULT CURRENT BASED ON PREVIOUS PROJECT, TYP. 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3009 S Daimler St 11/18/2024 1L21-1-3-5 16 2 2 39 39 4 4 4 4 39 32 32 14,16 PBW1 PBW4 1 3 TYP 4 TYP 2 6 TYP 16 8 PBW21 PBW31 1 3 5 1 3 5 7 9 11 7 9 11 7 13 13 9 1L21-7-9-11 9 10 1L21-13 1L21-15,17 1L21-19,21 1L21-41,43 1L21-27,291L21-31,331L21-35,37 1L21-2,4,6 1L21-8 1L21-10,1211 J 1L21-39 1L21-23-251L21-16 1L21-18,20,22 12 1L21-24 7 7 HM3-37,39,41 1L22-2 8 1L22-6,8 1L22-4 J 1L22-10 23 25 1L21-261L21-281L21-30 1L22-1,3,51L22-7,9,11 1L22-131L22-18 5 TYP 1L22-12-14,16 1L22-20 1L22-22,24 1L22-32 1L22-26,28,301L22-34,36,381L22-40,42,441L22-46,48,50 9 PBW E6.1 TYP 12 1L21-32 17 15 1L22-15-17 9 14 TYP 15 TYP 1L21-45 1L22-43 16 17 1 2 3 4 D E LAB POWER PLAN SCALE: 1/4"=1'-0"_XREFA POWER KEYNOTES 1.PROVIDE 26FT LONG, 225A-120/208V-3PH-4W OVERHEAD PLUG-IN BUSWAY WITH COPPER BUSSING, ALL REQUIRED ACCESSORIES, MOUNTING HARDWARE, BUS CONNECTORS, END FEED UNITS, LABOR, TESTING ETC. NECESSARY TO PROVIDE A COMPLETE, OPERABLE, AND CODE COMPLIANT SYSTEM. PROVIDE SUPPORTS EVERY 4FT AND SEISMIC BRACING AS REQUIRED. COORDINATE WITH STRUCTURAL. MOUNT BOTTOM OF BUSWAY AT 10 FT AFF OR AS DIRECTED BY EDWARDS. VERIFY PRIOR TO INSTALL. PROVIDE PLUG-IN UNITS TO MATCH EQUIPMENT. PROVIDE SPARE UNITS AS DIRECTED BY EDWARDS. PROVIDE STARLINE T3 SERIES OR EQUAL 2.PROVIDE 40FT LONG, 500A-120/208V-3PH-4W OVERHEAD PLUG-IN BUSWAY WITH INTERNAL GROUND BUS, COPPER BUSSING, ALL REQUIRED ACCESSORIES, MOUNTING HARDWARE, BUS CONNECTORS, END FEED UNITS, LABOR, TESTING ETC. NECESSARY TO PROVIDE A COMPLETE, OPERABLE, AND CODE COMPLIANT SYSTEM. PROVIDE SUPPORTS EVERY 4 FT AND SEISMIC BRACING AS REQUIRED. COORDINATE WITH STRUCTURAL. MOUNT BOTTOM OF BUSWAY AT 10FT AFF OR AS DIRECTED BY EDWARDS. VERIFY PRIOR TO INSTALL. PROVIDE PLUG-IN UNITS TO MATCH EQUIPMENT. PROVIDE SPARE UNITS AS DIRECTED BY EDWARDS. PROVIDE STARLINE T5 SERIES OR EQUAL. 3.PROVIDE DUAL-SERVICE (POWER AND DATA) WALL MOUNTED RACEWAY WITH 20A-125V DUPLEX RECEPTACLES AND DATA OUTLETS ON 6 FT CENTERS. FIELD VERIFY LENGTHS AND ADJUST AS NECESSARY. PROVIDE LEGRAND ALUMINUM ALA4800 OR EQUAL. MOUNT AT 24" AFF OR AS DIRECTED BY EDWARDS. RECEPTACLES SHALL BE ON ALTERNATING CIRCUITS WITH A TARGET OF 2 RECEPTACLES PER CIRCUIT. PROVIDE 1"CO FOR EVERY (3) DATA OUTLETS STUBBED 6" ABOVE ACCESSIBLE CEILING SPACE FOR DATA CABLES. VERIFY QUANTITIES, INTERVALS, AND LOCATIONS WITH EDWARDS DATA CONTRACTOR. PROVIDE ALL REQUIRED CONDUIT, CONDUCTORS, CONNECTORS, ACCESSORIES, MOUNTING HARDWARE, ETC. NECESSARY TO PROVIDE A COMPLETE, OPERABLE, AND CODE COMPLIANT SYSTEM. VERIFY EXACT LOCATION AND REQUIREMENTS PRIOR TO INSTALL AND ADJUST AS NECESSARY. 4.PROVIDE SPECIAL RECEPTACLE IN WALL MOUNTED RACEWAY FOR SPECIFIC EQUIPMENT. VERIFY DIMENSION WITH EDWARDS. PROVIDE DEDICATED CIRCUIT AS INDICATED. VERIFY RECEPTACLE CONFIGURATION AND EXACT LOCATION PRIOR TO INSTALL AND ADJUST AS NECESSARY. 5.CONNECT TO EQUIPMENT AS REQUIRED. VERIFY EXACT LOCATION AND REQUIREMENTS PRIOR TO INSTALL AND ADJUST AS NECESSARY. 6.PROVIDE LARGE, DUAL SERVICE, ALUMINUM POWER POLE WITH POWER AND DATA OUTLETS INDICATED. PROVIDE POLE LENGTH AND ALL INTERNAL AND EXTERNAL MOUNTING HARDWARE. LOCATE POWER POLES 10" FROM WALLS. POWER POLES SHALL NOT BE SUPPORTED OR ATTACHED TO WALL. PROVIDE LEGRAND NP8000 OR EQUAL. 7.FOR EQUIPMENT CONTROL POWER. VERIFY EXACT LOCATION AND REQUIREMENTS PRIOR TO INSTALL AND ADJUST AS NECESSARY. 8.PROVIDE CONDUIT AND BOXES PER EDWARDS AND BUILDING STANDARD FOR CARD READER. 9.PROVIDE A SEPARATE NEUTRAL FOR EACH CIRCUIT. 10.PROVIDE #10 AWG CIRCUIT CONDUCTORS TO RECEPTACLES IN WALL MOUNTED RACEWAY. 11.PROVIDE 2#4-1#8G-1"C. EXTEND SAME FROM DISCONNECT TO EQUIPMENT AS REQUIRED. 12.PROVIDE NEMA L21-30 RECEPTACLE. CONNECT TO EQUIPMENT AS REQUIRED. VERIFY EXACT LOCATION AND REQUIREMENTS PRIOR TO INSTALL AND ADJUST AS NECESSARY. 13.NEW ELECTRICAL EQUIPMENT SHALL FIT IN ALLOTTED SPACE WITH EQUIPMENT AND CODE REQUIRED CLEARANCES. CONTRACTOR SHALL COORDINATE EQUIPMENT DIMENSIONS WITH FIELD CONDITIONS PRIOR TO BID. VERIFY EXACT LOCATIONS IN FIELD AND WITH EDWARDS. 14.INDICATES CODE REQUIRED CLEARANCE. 15.MAINTAIN MANUFACTURER'S REQUIRED CLEARANCE FROM WALLS AND OTHER EQUIPMENT. 16.PROVIDE 20A-125V GFCI DUPLEX RECEPTACLE PER 210.63(B)(2). RECEPTACLE SHALL NOT BE CONNECTED TO THE LOAD SIDE OF THE EQUIPMENT'S BRANCH CIRCUIT DISCONNECTING MEANS. 17.AREA FOR FUTURE PANELS. KEEP CLEAR FROM FLOOR TO CEILING. DO NOT INSTALL EQUIPMENT IN THIS AREA WITHOUT PRIOR APPROVAL FROM EDWARDS. 18.DISTRIBUTION BOARD SHALL NOT BE WIDER THAN 6FT. # SEE SPECIFICATIONS, GENERAL NOTES, SYMBOLS, AND ASSOCIATED REQUIREMENTS. CONTRACTOR SHALL THOROUGHLY REVIEW ALL SPECIFICATIONS, NOTES AND SYMBOLS AND INCLUDE ALL REQUIREMENTS IN HIS BID. VERIFY ALL LOCATIONS AND REQUIREMENTS PRIOR TO INSTALL. REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 23 2 7 6 S O U T H P O I N T E D R . , U N I T 1 0 2 , LA G U N A H I L L S , C A 9 2 6 5 3 O: 9 4 9 - 4 1 9 - 9 9 0 8 F : 9 4 9 - 4 1 9 - 9 8 7 0 E4.1 LAB POWER PLAN LOW VOLTAGE CONDUIT NOTE ALL LOW VOLTAGE DATA/COMM/CONTROL CONDUITS SHALL BE FACTORY COATED BLUE. PROVIDE SAMPLE TO EDWARDS FOR APPROVAL PRIOR TO ORDERING. VERIFY RECEPTACLE TYPE WITH EQUIPMENT PRIOR TO INSTALL AND ADJUST AS NECESSARY. PROVIDE PERMANENT LABEL ON EACH DEVICE INDICATING PANEL AND CIRCUIT NUMBER PER EDWARDS STANDARDS. ALL 120V CIRCUITS SHALL INCLUDE A DEDICATED NEUTRAL. MULTI-WIRE BRANCH CIRCUITS ARE NOT ALLOWED. ALL 120V RECEPTACLES SHALL BE RATED 20A. PROVIDE NEMA 5-20R. UPDATE AND PROVIDE TYPEWRITTEN PANEL CARDS FOR ALL PANELS AFFECTED BY THIS WORK. SUBMIT PANEL SCHEDULES TO EDWARDS AND ENGINEER FOR REVIEW PRIOR TO POSTING NEW SCHEDULES AT PANELS. ALL SPARE CIRCUIT BREAKERS SHALL BE LOCKED OUT / TAGGED OUT OR LEFT IN THE OFF/OPEN POSITION AS DIRECTED BY EDWARDS. PROVIDE GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL ON RECEPTACLES PER 210.8(B) AND SPECIFICALLY WITHIN 6FT FROM SINKS AND DAMP AND WET LOCATIONS. VERIFY IN FIELD WITH EDWARDS. T-DBL2 DBL2 ALL SWITCHBOARDS, SWITCHGEAR, PANELBOARDS, AND MOTOR CONTROL CENTERS SHALL BE LOCATED IN DEDICATED SPACES AND PROTECTED FROM DAMAGE PER 110.26(E)(1) FOR INDOOR OR 110.26(E)(2) FOR OUTDOOR. 13 1 1 1 HM3 1L21 1L22 1 1 1111 11 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1 111 1 11 1 1 11 1 18 3009 S Daimler St 11/18/2024 AC 9 AC 11 AC 12 AC 10 EF 9 EF 8 EF 7 EF 11 EF 10 45 45 45 DSD DSD DSD DSD HM3-20,22,24 HM3-14,16,18HM3-8,10,12 HM3-2,4,6 HM3-26,28,30 1L22-45 HM3-13,15,17 1L22-47,49 HM3-1,3,5 HM3-7,9,11 J 45 45 4545 1L22-51 EF 12 1 2 3 4 D E ROOF POWER PLAN SCALE: 1/4"=1'-0"_XREFA SEE SPECIFICATIONS, GENERAL NOTES, SYMBOLS, AND ASSOCIATED REQUIREMENTS. CONTRACTOR SHALL THOROUGHLY REVIEW ALL SPECIFICATIONS, NOTES AND SYMBOLS AND INCLUDE ALL REQUIREMENTS IN HIS BID. VERIFY ALL LOCATIONS AND REQUIREMENTS PRIOR TO INSTALL. REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 23 2 7 6 S O U T H P O I N T E D R . , U N I T 1 0 2 , LA G U N A H I L L S , C A 9 2 6 5 3 O: 9 4 9 - 4 1 9 - 9 9 0 8 F : 9 4 9 - 4 1 9 - 9 8 7 0 E4.2 ROOF POWER PLAN VERIFY RECEPTACLE TYPE WITH EQUIPMENT PRIOR TO INSTALL AND ADJUST AS NECESSARY. PROVIDE PERMANENT LABEL ON EACH DEVICE INDICATING PANEL AND CIRCUIT NUMBER PER EDWARDS STANDARDS. ALL 120V CIRCUITS SHALL INCLUDE A DEDICATED NEUTRAL. MULTI-WIRE BRANCH CIRCUITS ARE NOT ALLOWED. ALL 120V RECEPTACLES SHALL BE RATED 20A. PROVIDE NEMA 5-20R. UPDATE AND PROVIDE TYPEWRITTEN PANEL CARDS FOR ALL PANELS AFFECTED BY THIS WORK. SUBMIT PANEL SCHEDULES TO EDWARDS AND ENGINEER FOR REVIEW PRIOR TO POSTING NEW SCHEDULES AT PANELS. ALL SPARE CIRCUIT BREAKERS SHALL BE LOCKED OUT / TAGGED OUT OR LEFT IN THE OFF/OPEN POSITION AS DIRECTED BY EDWARDS. 1 3009 S Daimler St 11/18/2024 WSP65 51 TYP WSP65E 51 TYP EDG 5 TYP 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 HL1-17a HL1-17a HL1-17a HL1-17a HL1-17a HL1-17e HL1-17fHL1-17aHL1-17a HL1-17a HL1-17a HL1-17a HL1-17a HL1-17e HL1-17fHL1-17a HL1-17a HL1-17a HL1-17a HL1-17a HL1-17e HL1-17a HL1-17a HL1-17a HL1-17a HL1-17a HL1-17e HL1-17a HL1-17a HL1-17a HL1-17a HL1-17a HL1-17e HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15b HL1-15c HL1-15c HL1-15c HL1-15c HL1-15d HL1-15d EHL1-5aEM EHL1-5fEM EHL1-5fEMEHL1-5aEM EHL1-5aEM EHL1-5fEM EHL1-5bEM EHL1-5bEM EHL1-5cEM EHL1-5dEM S4 aef aef S1 b S1 b S1 c S1 d b b b bbb b c c c d EHL1-5EM EHL1-5EM HL1-17a HL1-15bHL1-15b HL1-15b EHL1-5aEM HL1-15cHL1-15cHL1-15c HL1-15cHL1-15c J J J J J J J J J EHL1-5 JHL1-17 J HL1-15 J J J S4 aef aef aef aef aef aef aef aef aef aef aef aef P2 ef CLX40 28 TYP $ HM3-35 1 2 3 4 D E LAB LIGHTING PLAN SCALE: 1/4"=1'-0"_XREFA SEE SPECIFICATIONS, GENERAL NOTES, SYMBOLS, AND ASSOCIATED REQUIREMENTS. CONTRACTOR SHALL THOROUGHLY REVIEW ALL SPECIFICATIONS, NOTES AND SYMBOLS AND INCLUDE ALL REQUIREMENTS IN HIS BID. VERIFY ALL LOCATIONS AND REQUIREMENTS PRIOR TO INSTALL. REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 23 2 7 6 S O U T H P O I N T E D R . , U N I T 1 0 2 , LA G U N A H I L L S , C A 9 2 6 5 3 O: 9 4 9 - 4 1 9 - 9 9 0 8 F : 9 4 9 - 4 1 9 - 9 8 7 0 E4.5 LAB LIGHTING PLAN nLIGHT LIGHTING CONTROLS CONTRACTOR SHALL PROVIDE ALL NECESSARY nLIGHT CONTROL MODULES, SENSORS, SWITCHES, 0-10V CONDUCTORS, CAT5 CABLES, BRIDGES, POWER SUPPLIES, CONDUIT, LABOR, PROGRAMMING, TESTING, ETC., NECESSARY TO PROVIDE A COMPLETE OPERABLE AND CODE COMPLIANT LIGHTING SYSTEM TO MEET DESIGN INTENT. PROVIDE FACTORY STARTUP AND TESTING. INDOOR ENERGY CODE CONTROL NOTES (PER CURRENT CALIFORNIA ENERGY CODE, UNLESS OTHERWISE NOTED) BUILDINGS WITH NONRESIDENTIAL LIGHTING SYSTEMS HAVING A TOTAL INSTALLED LIGHTING POWER OF 4,000 WATTS OR GREATER THAT ARE SUBJECT TO THE MULTILEVEL LIGHTING CONTROL REQUIREMENTS OF SECTION 130.1(b) SHALL INCLUDE A DEMAND RESPONSE SYSTEM PER 110.12(c) FOR LIGHTING, 110.12(d) FOR ELECTRONIC MESSAGE CENTERS, AND 110.12(e) FOR CONTROLLED RECEPTACLES. PROVIDE OCCUPANCY SENSING CONTROLS IN OFFICE 250SF OR LESS, MULTIPURPOSE ROOMS 1,000SF OR LESS, CLASSROOMS, CONFERENCE ROOMS AND RESTROOMS. IN OFFICES GREATER THAN 250SF OCCUPANCY SENSING CONTROLS SHALL BE CONFIGURED SO THAT LIGHTING SHALL BE CONTROLLED SEPARATELY IN CONTROL ZONES NOT GREATER THAN 600SF PER 130.1(c)6D. OCCUPANCY SENSING CONTROLS IN CONDITIONED AREAS SHALL BE SET TO AUTOMATICALLY SHUT OFF ALL CONTROLLED LIGHTING IN 20 MINUTES OR LESS AFTER THE CONTROL ZONE IS UNOCCUPIED. THE OCCUPANCY SENSING CONTROLS IN THESE AREAS SHALL FUNCTION AS VACANCY SENSING, WHERE ALL LIGHTING RESPONDS TO MANUAL ON INPUT ONLY. IN CORRIDORS AND STAIRWELLS, LIGHTING SHALL BE CONTROLLED BY OCCUPANCY SENSING CONTROLS THAT SEPARATELY REDUCE THE LIGHTING POWER IN EACH SPACE BY AT LEAST 50% WHEN THE SPACE IS UNOCCUPIED PER130.1(c)6D. PROVIDE AUTOMATIC DAYLIGHTING CONTROLS PER 130.1(d) EXCEPT ROOMS WHERE THE COMBINED TOTAL INSTALLED WATTAGE OF THE GENERAL LIGHTING IN THE SKYLIT AND PRIMARY SIDELIT ZONES IS LESS THAN 120 WATTS ARE NOT REQUIRED TO HAVE DAYLIGHTING CONTROLS FOR THOSE ZONES. ROOMS WHERE THE TOTAL INSTALLED WATTAGE OF THE GENERAL LIGHTING IN THE SECONDARY SIDELIT ZONES IS LESS THAN 120 WATTS ARE NOT REQUIRED TO HAVE DAYLIGHTING CONTROLS FOR THAT ZONE. WAREHOUSE LUMINAIRES SHALL INCLUDE INTEGRAL OCCUPANCY SENSORS AND PHOTOSENSORS. EACH LUMINAIRE SHALL BE ITS OWN CONTROL ZONE. THE MAXIMUM COMBINED VOLTAGE DROP ON BOTH INSTALLED FEEDER CONDUCTORS AND BRANCH CIRCUIT CONDUCTORS TO THE FARTHEST CONNECTED LOAD OR OUTLET SHALL NOT EXCEED 5 PERCENT PER 130.5(c). EMERGENCY EGRESS LUMINAIRES SHALL TURN ON/OFF AND DIM WITH AREA CONTROLS AND SHALL ILLUMINATE AT FULL OUTPUT UPON LOSS OF NORMAL POWER, REGARDLESS OF CONTROL POSITION. PROVIDE UNSWITCHED HOT CONDUCTOR TO EACH BATTERY AS REQUIRED. AUTOMATIC DAYLIGHTING CONTROLS IN AREAS SERVED BY LIGHTING THAT IS DAYLIGHT CONTROLLED, WHEN THE DAYLIGHT ILLUMINANCE IS GREATER THAN 150 PERCENT OF THE ILLUMINANCE PROVIDED BY THE CONTROLLED LIGHTING WHEN NO DAYLIGHT IS AVAILABLE, THE CONTROLLED LIGHTING POWER IN THAT DAYLIGHT ZONE SHALL BE REDUCED BY A MINIMUM OF 90 PERCENT. INDICATES PRIMARY DAYLIT BOUNDRY INDICATES SECONDARY DAYLIT BOUNDRY INDICATES SKYLIT BOUNDRY MANUFACTURED WIRING SYSTEM PROVIDE A COMPLETE MANUFACTURED WIRING SYSTEM FOR ALL LIGHT FIXTURES IN ACCESSIBLE T-BAR CEILINGS. SYSTEM SHALL INCLUDE ALL CONNECTIONS TO FIXTURES AND CONTROLS WITH ALL REQUIRED SYSTEM COMPONENTS. EQUIPMENT SHALL BE LITHONIA OR AMERICAN CABLE COMPANY. PROVIDE TRADITIONAL CONDUIT AND CONDUCTORS TO DEVICES IN HARD LID CEILINGS, WHERE THE CABLES ARE INACCESSIBLE AND TO EMERGENCY FIXTURES FED FROM AN ALTERNATE SOURCE SUCH AS AN INVERTER OR GENERATOR AS REQUIRED. EXACT LOCATIONS AND QUANTITIES OF EXIT SIGNS ARE TO BE DETERMINED BY ARCHITECT. 1 HM3 3009 S Daimler St 11/18/2024 1 2 3 4 D E NORMAL PHOTOMETRIC PLAN SCALE: 1/4"=1'-0"_XREFA REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 23 2 7 6 S O U T H P O I N T E D R . , U N I T 1 0 2 , LA G U N A H I L L S , C A 9 2 6 5 3 O: 9 4 9 - 4 1 9 - 9 9 0 8 F : 9 4 9 - 4 1 9 - 9 8 7 0 E4.6 NORMAL PHOTOMETRICS PHOTOMETRIC DISCLAIMER: THIS PHOTOMETRIC STUDY HAS BEEN PERFORMED IN ACCORDANCE WITH IESNA STANDARDS AND INDUSTRY LIGHTING PRACTICES. INPUT DATA FILES ARE PROVIDED BY THE MANUFACTURER OF SPECIFIED LIGHT FIXTURES. DIFFERENCES MAY OCCUR BETWEEN CALCULATIONS AND ACTUAL INSTALLED CONDITIONS DUE TO TEST PROCEDURES, EQUIPMENT PERFORMANCE, MEASUREMENT TECHNIQUES AND FIELD CONDITIONS SUCH AS TEMPERATURE, VOLTAGE AND REFLECTANCE FROM CEILINGS, WALLS AND FLOORS. ARCHITECTURAL ELEMENTS, ROOM SIZES AND MOUNTING HEIGHTS SIGNIFICANTLY AFFECT THE LIGHTING CALCULATIONS. IF REAL CONDITIONS DIFFER FROM CALCULATED CONDITIONS, LIGHT LEVELS MAY VARY. K2M ENGINEERING IS NOT RESPONSIBLE FOR THE ACCURACY OF THE MANUFACTURER'S INFORMATION. NUMBER INDICATES NORMAL LIGHT LEVEL, IN FOOT-CANDLES, AT 30" AFF, TYP. Normal Lighting Statistics Description Symbol Avg Max Min Max/Min Avg/Min Braiding 77 fc 94 fc 35 fc 2.7:1 2.2:1 Extrusion 78 fc 108 fc 30 fc 3.6:1 2.6:1 Lab 94 fc 122 fc 21 fc 5.8:1 4.5:1 Tool 52 fc 60 fc 40 fc 1.5:1 1.3:1 3009 S Daimler St 11/18/2024 1 2 3 4 D E EGRESS PHOTOMETRIC PLAN SCALE: 1/4"=1'-0"_XREFA REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 23 2 7 6 S O U T H P O I N T E D R . , U N I T 1 0 2 , LA G U N A H I L L S , C A 9 2 6 5 3 O: 9 4 9 - 4 1 9 - 9 9 0 8 F : 9 4 9 - 4 1 9 - 9 8 7 0 E4.7 EGRESS PHOTOMETRICS PHOTOMETRIC DISCLAIMER: THIS PHOTOMETRIC STUDY HAS BEEN PERFORMED IN ACCORDANCE WITH IESNA STANDARDS AND INDUSTRY LIGHTING PRACTICES. INPUT DATA FILES ARE PROVIDED BY THE MANUFACTURER OF SPECIFIED LIGHT FIXTURES. DIFFERENCES MAY OCCUR BETWEEN CALCULATIONS AND ACTUAL INSTALLED CONDITIONS DUE TO TEST PROCEDURES, EQUIPMENT PERFORMANCE, MEASUREMENT TECHNIQUES AND FIELD CONDITIONS SUCH AS TEMPERATURE, VOLTAGE AND REFLECTANCE FROM CEILINGS, WALLS AND FLOORS. ARCHITECTURAL ELEMENTS, ROOM SIZES AND MOUNTING HEIGHTS SIGNIFICANTLY AFFECT THE LIGHTING CALCULATIONS. IF REAL CONDITIONS DIFFER FROM CALCULATED CONDITIONS, LIGHT LEVELS MAY VARY. K2M ENGINEERING IS NOT RESPONSIBLE FOR THE ACCURACY OF THE MANUFACTURER'S INFORMATION. NUMBER INDICATES EMERGENCY LIGHT LEVEL, IN FOOT-CANDLES, AT FLOOR LEVEL, TYP. Egress Lighting Statistics Description Symbol Avg Max Min Max/Min Avg/Min Braiding 5.6 fc 20.3 fc 1.0 fc 20.3:1 5.6:1 Extrusion 9.6 fc 22.8 fc 0.7 fc 32.6:1 13.7:1 Lab 11.8 fc 26.7 fc 1.4 fc 19.1:1 8.4:1 Tool 14.3 fc 22.2 fc 3.3 fc 6.7:1 4.3:1 3009 S Daimler St 11/18/2024 GENERAL PANEL NOTES: (UNLESS OTHERWISE NOTED, SOME MAY NOT APPLY) A.CONTRACTOR SHALL VERIFY ALL LOCATIONS, MOUNTING HEIGHTS, CONNECTIONS AND REQUIREMENTS WITH OTHER TRADES, OWNER, ARCHITECT AND/OR TENANT AS APPLICABLE PRIOR TO INSTALL AND ADJUST ACCORDINGLY. CONTRACTOR SHALL REVIEW ALL OTHER TRADE'S DRAWINGS AND INCLUDE IN HIS BID ALL COSTS APPLICABLE TO THE ELECTRICAL TRADE WHETHER SHOWN IN THESE DRAWINGS OR NOT.ALL TERMINAL LUGS SHALL BE RATED FOR THE CONDUCTOR SIZE AND QUANTITY SHOWN ON THE SINGLE LINE DIAGRAM AND ASSOCIATED FEEDER SCHEDULE. B.ALL TERMINAL LUGS SHALL BE RATED FOR 75 DEGREE C AND FOR THE CONDUCTOR MATERIAL SPECIFIED ON THE SINGLE LINE DIAGRAM AND ASSOCIATED FEEDER SCHEDULE. C.ALL PANEL BOARDS WITH MAIN CIRCUIT BREAKERS SHALL HAVE THE MAIN CIRCUIT BREAKER INDIVIDUALLY MOUNTED TO ELIMINATE BUS SUPPORTS WHERE POSSIBLE. BACK FEED OF CHASSIS CIRCUIT BREAKERS IS NOT ALLOWED. D.ALL NEW CIRCUIT BREAKERS FOR HVAC EQUIPMENT SHALL BE "HACR" TYPE. E.ALL NEW CIRCUIT BREAKERS FOR LIGHTING CIRCUITS SHALL BE "SWD" RATED. F.ALL NEW SINGLE POLE CIRCUIT BREAKERS SHALL BE COMPATIBLE WITH MANUFACTURE'S LISTED HANDLE TIES. G.PROVIDE MULTI-POLE CIRCUIT BREAKERS OR MANUFACTURE'S LISTED HANDLE TIES ON ALL NEW MULTI-WIRE BRANCH CIRCUITS PER CODE REGARDLESS OF WHETHER SHOWN ON THESE DRAWINGS OR NOT. WHERE EXISTING CIRCUIT BREAKERS ARE USED, IF MANUFACTURER'S LISTED HANDLE TIES CANNOT BE OBTAINED, REPLACE CIRCUIT BREAKERS THAT FEED MULTI-WIRE BRANCH CIRCUITS WITH COMPARABLE MULTI-POLE CIRCUIT BREAKERS. H.PROVIDE AT LEAST 10% SPARE 20-AMP 1-POLE CIRCUIT BREAKERS IN EACH NEW PANEL WHETHER SHOWN OR NOT. IF LESS 10% SPACES ARE AVAILABLE, FILL THE REMAINING SPACES WITH SPARE CIRCUIT BREAKERS AS INDICATED ABOVE. I.WHERE THE CIRCUIT CONDUCTOR SIZE EXCEEDS THE LUG RATING OF THE CIRCUIT BREAKER, PROVIDE A LISTED PIN ADAPTOR. IF A LISTED PIN ADAPTOR IS NOT AVAILABLE, PROVIDE A SPLICE BOX DIRECTLY ABOVE THE PANEL AND REDUCE THE CONDUCTOR TO THE MAXIMUM SIZE FOR WHICH THE CIRCUIT BREAKER IS LISTED. J.PROVIDE PERMANENT PLACARDS ON ALL NEW AND MODIFIED PANELS THAT INDICATE THE PANEL NAME, FEEDER RATING INCLUDING: AMPS-VOLTS-PHASES-WIRES. PLACARD SHALL ALSO INCLUDE SOURCE OF SUPPLY PER 408.4(B). K.ALL NEW AND MODIFIED PANEL CARDS SHALL BE TYPED AND SHALL INCLUDE DATE. RECREATE PANEL CARDS FOR ANY PANELS THAT ARE MODIFIED. CIRCUIT BREAKER ABBREVIATIONS (SOME MAY NOT BE USED) {RE}RECONNECT EXISTING LOAD TO NEW CIRCUIT BREAKER AS REQUIRED. {LO}PROVIDE PERMANENT LOCK-OFF DEVICE ON CIRCUIT BREAKER. {NC}PROVIDE NEW CIRCUIT BREAKER TO MATCH EXISTING CIRCUIT BREAKERS CHARACTERISTICS. NEW CIRCUIT BREAKER'S AIC RATING SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT. {UE}UTILIZE EXISTING CIRCUIT BREAKER. {CC}ROUTE CIRCUIT THROUGH CONTROL CONTACT OR TIME CLOCK AS APPLICABLE. {GF}PROVIDE "GFCI" TYPE CIRCUIT BREAKER. PROVIDE SEPARATE NEUTRAL FOR CIRCUIT AS APPLICABLE. {LR}CIRCUIT LOAD HAS BEEN REVISED TO REFLECT CHANGES TO EXISTING CIRCUIT. {ST}PROVIDE SHUNT TRIP CIRCUIT BREAKER. {HT}PROVIDE MANUFACTURE'S LISTED HANDLE TIE ON EXISTING CIRCUIT BREAKER. TIE TO THE ADJACENT CIRCUIT BREAKER WHO'S CIRCUIT SHARES A NEUTRAL CONDUCTOR. PROVIDE 2-POLE OR 3-POLE HANDLE TIE AS REQUIRED. IF MANUFACTURE'S LISTED HANDLE TIES ARE NOT AVAILABLE, REPLACE CIRCUIT BREAKERS THAT FEED MULTI-WIRE BRANCH CIRCUITS WITH COMPARABLE MULTI-POLE CIRCUIT BREAKERS. {CS}PROVIDE EMON DMON SPLIT-CORE CURRENT SENSOR ON EACH CIRCUIT CONDUCTOR TO COMPLY WITH CALIFORNIA ENERGY CODE DISAGGREGATION REQUIREMENTS. CURRENT SENSORS SHALL BE PROPERLY RATED FOR THE CIRCUIT. CONTRACTOR SHALL CAP AND MAKE SAFE THE CURRENT SENSOR LEADS. CURRENT TRANSFORMERS SHALL NOT BE USED. {FA} PROVIDE RED CIRCUIT BREAKER WITH PERMANENT LOCK-ON DEVICE. {ON}PROVIDE PERMANENT LOCK-ON DEVICE ON CIRCUIT BREAKER {AF}PROVIDE LISTED COMBINATION-TYPE ARC-FAULT CIRCUIT INTERUPTER CIRCUIT BREAKER AS REQUIRED. COMPLY WITH 210.12. OFF INDICATES EXISTING CIRCUIT BREAKER WAS IN THE OPEN (OFF) POSITION WHEN VISUAL OBSERVATION WAS CONDUCTED. "OFF" MAY BE LOCATED ADJACENT TO THE CIRCUIT NUMBER OR IN THE DESCRIPTION. CONTRACTOR SHALL FULLY VERIFY THE CIRCUIT AND REPORT BACK TO ENGINEER. LUMINAIRE SCHEDULE ALL FIXTURES ARE LED UNLESS OTHERWISE NOTED ALL FIXTURES SHALL MEET OR EXCEED OWNER AND TENANT REQUIREMENTS (SOME MAY NOT BE USED) LUMEN PACKAGE COLOR TEMP VOLTAGE DESCRIPTION MANUFACTURER'S PART NUMBER WSP65 51 6500 5000K 120/277 2X4 CENTER BASKET WITH SOFT WHITE ACRYLIC CENTER SHEILDING, 10% DIMMING, MOUNT IN T-BAR GRID. MARK LIGHTING # WHSPR 2X4 80CRI 50K 6500LM MIN10 MVOLT SWC ZT MATCH BUILDING STANDARD WSP65E 51 6500 5000K 120/277 SAME AS TYPE WSP65 EXCEPT CONNECTED TO EMERGENCY GENERATOR CIRCUIT. MARK LIGHTING # WHSPR 2X4 80CRI 50K 6500LM MIN10 MVOLT SWC ZT MATCH BUILDING STANDARD EDG 5 --120/277 EXIT SIGN, EDGE-LIT, FACES PER PLANS, BRUSHED ALUMINUM, GREEN LETTERS ON CLEAR FACE, 90 MINUTE NI-CAD BATTERY, SELF-DIAGNOSTICS. WALL MOUNT ABOVE DOOR AS DIRECTED BY ARCHITECT. LITHONIA # EDG * G/GMR EL SD * NUMBER OF FACES PER PLANS VERIFY LETTER COLOR WITH ARCHITECT. MATCH BUILDING STANDARD. CLX40 28 4000 3500K 120/277 STRIP LIGHT, SURFACE MOUNT OR CHAIN HANG AS DIRECTED BY ARCHITECT. LITHONIA # CLX L48 4000LM SEF L WD MVOLT GZ10 35K 80CRI WH TYPE WATTS REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 23 2 7 6 S O U T H P O I N T E D R . , U N I T 1 0 2 , LA G U N A H I L L S , C A 9 2 6 5 3 O: 9 4 9 - 4 1 9 - 9 9 0 8 F : 9 4 9 - 4 1 9 - 9 8 7 0 E5.1 SCHEDULES MECHANICAL/PLUMBING EQUIPMENT SCHEDULE ELECTRICAL LOAD VOLTAGE DISCONNECT SWITCH FUSE SIZE NEMA STARTER SIZE EQUIPMENT SCHEDULE NOTES COMMENTS AC-9 19 MCA 480V-3PH 30A-3P-600V NEMA 3R FUSED 20 - AC-10 13 MCA 480V-3PH 30A-3P-600V NEMA 3R FUSED 20 - AC-11 8 MCA 480V-3PH 30A-3P-600V NEMA 3R FUSED 15 - AC-12 18.1 MCA 208V-1PH 30A-2P-240V NEMA 3R FUSED 25 - EF-7, EF-8, EF-9, EF-10, EF-11 1 HP 2.1 FLA 480V-3PH INTEGRAL TO VFD ---PROVIDE CONTROL CONDUITS AND CONDUCTORS PER MECHANICAL. EF-12 1/2 HP 9.8 FLA 120V MANUAL MOTOR STARTER ---PROVIDE CONTROL CONDUITS AND CONDUCTORS PER MECHANICAL. ID # MECHANICAL/PLUMBING EQUIPMENT SCHEDULE NOTES: (SOME MAY NOT BE USED) a.PROVIDE COMBINATION MOTOR STARTER/ DISCONNECT SWITCH, NEMA 3R UNLESS OTHERWISE NOTED. b.PROVIDE NEMA 3R MANUAL MOTOR STARTER WITH THERMAL OVERLOAD PROTECTION. c.PROVIDE A 7-DAY PROGRAMMABLE TIME CLOCK WITH RESERVE POWER FOR CONTROL OF THE EXHAUST FAN. TIME CLOCK SHALL HAVE (2) INDEPENDENTLY CONTROLLED 20A MOTOR RATED CONTACTS RATED FOR THE CIRCUIT VOLTAGE. ROUTE FAN CIRCUIT THROUGH TIME CLOCK. d.PROVIDE 0-6 HOUR, SPRING WOUND BY-PASS TIME SWITCH WITH 20A CONTACTS RATED FOR THE CIRCUIT VOLTAGE. e.CONNECT TO WATER HEATER AS REQUIRED. PROVIDE LOCAL DISCONNECT OR PERMANENT LOCK-OFF DEVICE ON CIRCUIT BREAKER. f.ROUTE CIRCUIT THROUGH LINE VOLTAGE, HORSEPOWER RATED T-STAT. T-STAT BY MECHANICAL, VERIFY LOCATION. g.ROUTE CONTROL CIRCUIT THROUGH LIGHTING CONTROLLER. COORDINATE REQUIREMENTS WITH MECHANICAL AND ADJUST AS REQUIRED. PROVIDE PROGRAMMING OF CONTROLLER AS DIRECTED BY MECHANICAL. h.INTERLOCK WITH LIGHT SWITCH. PROVIDE MOTOR RATED CONTACT IN OCCUPANCY SENSOR. i.INTERLOCK BATTERY CHARGER EXHAUST FAN SUCH THAT UPON FAN FAILURE, POWER TO BATTERY CHARGERS IS INTERRUPTED. GENERAL MECHANICAL/PLUMBING EQUIPMENT NOTES (UNLESS OTHERWISE NOTED) A.CONTRACTOR SHALL COORDINATE ALL MECHANICAL AND PLUMBING EQUIPMENT REQUIREMENTS PRIOR TO BID AND INSTALL. B.ALL DISCONNECT SWITCHES SHALL BE NEMA 3R, 3-POLE, 600V, FUSED, HEAVY DUTY AND HORSEPOWER RATED, UNLESS OTHERWISE NOTED. ALL DISCONNECT SWITCHES SHALL MEET OR EXCEED THE RATING OF THE EQUIPMENT IT SUPPLIES. C.ALL MOTOR STARTERS SHALL BE RATED FOR THE APPLICATION. D.PROVIDE FUSES PER NAMEPLATE IF DIFFERENT FROM FUSE SIZE INDICATED. COMPLY WITH CODE. E.PROVIDE 24" OF SEAL TIGHT ON LINE SIDE OF DISCONNECT SWITCH TO MINIMIZE VIBRATION. PROVIDE EQUAL GROUND CONDUCTOR. F.PROVIDE 20A-125V GFI RECEPTACLES WITHIN 25FT OF ALL MECHANICAL EQUIPMENT. RECEPTACLES SHALL HAVE AN ENCLOSURE THAT IS WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG IS INSERTED. THE OUTLET BOX HOOD SHALL BE LISTED AND IDENTIFIED AS "EXTRA DUTY" PER ART. 406.9. G.PROVIDE 120V POWER TO ALL DUCT SMOKE DETECTORS AS REQUIRED. H.FOR EACH MECHANICAL UNIT, PROVIDE 3/4"CO STUBBED INTO ACCESSIBLE CEILING SPACE FOR CONTROLS. VERIFY EXACT REQUIREMENTS WITH MECHANICAL. I.FOR EACH SPLIT SYSTEM, PROVIDE 3/4"CO FOR CONTROLS AND 3/4" CO FOR POWER BETWEEN CONDENSER AND FAN COIL AS REQUIRED PER MECHANICAL. J.PROVIDE POWER AND CONTROLS TO ALL CIRCULATING PUMPS PER MECHANICAL/PLUMBING DRAWINGS. K.PROVIDE A UNISTRUT SUPPORT SYSTEM FOR ALL DISCONNECT SWITCHES, MOTOR STARTERS AND OTHER ELECTRICAL EQUIPMENT REQUIRED TO ENERGIZE MECHANICAL AND PLUMBING EQUIPMENT. UNISTRUT SYSTEM SHALL BE SUCH THAT IT DOES NOT VIBRATE DUE TO WIND. COORDINATE ATTACHMENT TO THE ROOF WITH THE ARCHITECT, GENERAL CONTRACTOR AND ROOFING CONTRACTOR TO ENSURE A WEATHERPROOF SEAL. IT IS ACCEPTABLE TO ATTACH ELECTRICAL EQUIPMENT TO THE MECHANICAL EQUIPMENT PROVIDED IT IS ACCEPTABLE TO MECHANICAL. ALL ELECTRICAL EQUIPMENT SHALL BE LOCATED SUCH THAT IT DOES NOT BLOCK EQUIPMENT ACCESS HATCHES. COORDINATE EXACT LOCATIONS WITH MECHANICAL PRIOR TO INSTALL. PROVIDE CODE REQUIRED CLEARANCES. L.PROVIDE ALL CONTROLS PER MECHANICAL AND PLUMBING INCLUDING, BUT NOT LIMITED TO: CONDUITS, CONDUCTORS, EQUIPMENT, ETC, NECESSARY TO PROVIDE A COMPLETE OPERABLE SYSTEM. COORDINATE EXACT REQUIREMENTS WITH MECHANICAL AND PLUMBING. CONTRACTOR SHALL COORDINATE WITH EDWARDS FOR ADDITIONAL SPARE DISCONNECTS FOR EACH BUSWAY. PLUG-IN UNIT GENERAL NOTES: A.PROVIDE PLUG-IN UNITS INDICATED IN BUSWAY SCHEDULES WITH ALL REQUIRED HARDWARE, CIRCUIT BREAKERS, CABLES, CONDUITS, RECEPTACLE, CONNECTORS, ETC, NECESSARY TO PROVIDE PROVIDE A COMPLETE, OPERABLE, AND CODE COMPLIANT SYSTEM THAT MEET THE DESIGN INTENT AND OWNER'S REQUIREMENTS. B.PLUG-IN UNITS SHALL BE OF THE SAME MANUFACTURER AS THE BUSWAY. C.PRIOR TO ORDERING, VERIFY CABLE LENGTHS AND CONNECTION TYPES WITH EDWARDS. ADJUST AS NECESSARY. D.PLUG-IN UNITS SHALL INCLUDE CIRCUIT BREAKER RATED FOR THE CONNECTION DEVICE AND SHALL BE ON THE ELECTRICAL PHASE SHOWN ON THE BUSWAY SCHEDULE. BALANCE LOADS AS NECESSARY. E.COORDINATE BUSWAY POLARIZING STRIP SO ALL PLUG-IN UNITS FACE THE SAME DIRECTION. VERIFY DIRECTION WITH EDWARDS. F.INSTALL PLUG IN UNITS AT THE LOCATIONS DIRECTED BY EDWARDS. G.OVERCURRENT DEVICES SHALL BE RATED 22KAIC MINIMUM.1 1 1 1 1 1 1 3009 S Daimler St 11/18/2024 MAIN RUNNERS 2'x4' FIXTURE 6" MAX LST-BAR LAYIN SUPPORT DETAIL N.T.S. SCALE #12 AWG STEEL WIRE CONNECTOR ATTACH TO PERMANENT STRUCTURE TYP. 4 PLACES TEX SCREW OPPOSITE CORNERS MAIN RUNNERS TYPICAL FOR 2'X2' OR 2'X4' FIXTURE COORDINATE EXACT MOUNTING REQUIREMENTS WITH ARCHITECTURAL AND STRUCTURAL. COMPLY WITH ALL APPLICABLE CODES AND STANDARDS. GFCI RECEPTACLE WITH EXTRA DUTY WHILE IN USE WEATHERPROOF ENCLOSURE 8" ROOF WEATHERPROOF BOX 3/4" MINIMUM RGS CONDUIT ROOF RECEPTACLE PENETRATION RRN.T.S. SCALE ROOF JACK WITH WEATHERPROOF SEAL COORDINATE PENETRATION AND MOUNTING WITH ARCHITECT, STRUCTURAL AND ROOFER. REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 23 2 7 6 S O U T H P O I N T E D R . , U N I T 1 0 2 , LA G U N A H I L L S , C A 9 2 6 5 3 O: 9 4 9 - 4 1 9 - 9 9 0 8 F : 9 4 9 - 4 1 9 - 9 8 7 0 E6.1 EQUIPMENT SCHEDULE AND DETAILS THE EQUIPMENT SCHEDULE IS DEVELOPED BY OTHERS, IS SHOWN FOR REFERENCE ONLY, AND IS THE BASIS OF THESE DRAWINGS. CONTRACTOR SHALL VERIFY EQUIPMENT REQUIREMENTS PRIOR TO INSTALL AND SHALL NOTIFY THE ENGINEER OF VARIATIONS. FOR BUSWAY CONNECTED DEVICES, PROVIDE THE APPROPRIATE PLUG-IN UNIT. COORDINATE ADDITIONAL PLUG-IN DEVICES WITH EDWARDS. GENERAL NOTES: 1.DETAIL IS GENERAL IN NATURE. 2.PROVIDE BUSWAY AND PLUG-IN UNITS PER PLANS. 3.PROVIDE ALL REQUIRED EQUIPMENT, CONNECTORS, MOUNTING HARDWARE, ETC., TO PROVIDE A COMPLETE, CODE COMPLIANT AND OPERABLE SYSTEM. COORDINATE WITH STRUCTURAL. PLUG-IN BUSWAY GENERAL DETAIL PBWN.T.S. SCALE 6'-0" AFF 10'-0" AFF STRUCTURAL CEILING FINISHED FLOOR PLUG-IN BUSWAY PLUG-IN UNIT WITH CIRCUIT BREAKER RATED FOR DEVICE FLEXIBLE CORD DROP WITH STRAIN RELIEF RECEPTACLE OR CONNECTION DEVICE VERIFY IN FIELD END POWER FEED WITH IR SCAN WINDOW PROVIDE UNISTRUT SUPPORT PER STRUCTURAL BUSWAY SUPPORTS PER STRUCTURAL WITH SEISMIC SUPPORTS EVERY 5FT ACOUSTIC CEILING TILE CUT HOLE IN CEILING FOR SUPPORTS & CONDUIT, INSTALL GROMMETS 3009 S Daimler St 11/18/2024 CALIFORNIA GREEN BUILDING CODE TESTING AND ADJUSTING (5.410.4) PLAN FOR TESTING AND ADJUSTING LIGHTING (INDOOR AND OUTDOOR) SYSTEMS AND CONTROLS COMPLY WITH THE TESTING AND ADJUSTING OF THE LIGHTING SYSTEMS AND CONTROLS USING STANDARD TITLE 24 CERTIFICATION OF ACCEPTANCE FORMS. THE FOLLOWING ARE THE STANDARDS THAT SHALL BE UTILIZED FOR THE TESTING AND VERIFICATION OF THE APPLICABLE LIGHTING SYSTEMS AND CONTROLS. PROVIDE THE FINAL REPORT FORMS AT FINAL INSPECTION. a.NA7.6.1 AUTOMATIC DAYLIGHTING CONTROL ACCEPTANCE TEST- NRCA-LTI-03-A b.NA7.6.2. SHUT-OFF CONTROLS CONTROLS ACCEPTANCE TEST- NRCA-LTI-02-A c.NA7.6.3 DEMAND RESPONSIVE CONTROLS FOR LIGHTING ACCEPTANCE TEST- NRCA-LTI-04-A d.NA7.6.4 LIGHTING CONTROLS INSTALLED TO EARN A PAF - FORM NRCA-LTI-05-A e.NA7.6.5 DEMAND RESPONSIVE CONTROLS FOR CONTROLLED RECEPTACLES ACCEPTANCE TEST- NRCA-LTI-04-A f.NA7.8 OUTDOOR LIGHTING SHUT-OFF CONTROLS - FORM NRCA-LTO-02-A BID NOTE: CONTRACTOR SHALL INCLUDE IN HIS BID ALL COSTS ASSOCIATED WITH ACCEPTANCE TESTING, INSTALLATION CERTIFICATION AND COMMISSIONING AS APPLICABLE. REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 23 2 7 6 S O U T H P O I N T E D R . , U N I T 1 0 2 , LA G U N A H I L L S , C A 9 2 6 5 3 O: 9 4 9 - 4 1 9 - 9 9 0 8 F : 9 4 9 - 4 1 9 - 9 8 7 0 E8.1 TITLE 24 ENERGY FORMS 3009 S Daimler St 11/18/2024 3009 S Daimler St 11/18/2024 CHICAGO BLOWER DESIGN 38 CAST ALUMINUM BLOWER ROOF BLUE M OVEN 900 150 6.5 9-3/4 x 2-7/8 3479 460 3 60 75- 1 MANUFACTURERMARK MODEL NO. EXHAUST FAN SCHEDULE REMARKSAREA SERVEDLOCATION HOUSING CFM ESP (IN. H O) WHEEL SIZE FAN RPM HP WATTS VOLT ELECTRICAL CYCLEPH. OPER. WEIGHT (LBS.) 2 EF 7 EF 8 MANUFACTURER MODEL NO. VOLTAGE MOTOR MARK CONTROL LOCATION HP MOTOR HZ RANGE, FREQUENCY DISCONNECT BYPASS REMARKSSERVICEAMP RATING ENCLOSURE OPER. WEIGHT (LBS.) - - COMUNICATION 460 2.11460EF-7ACH 580ABB 0-70 YES YES NEMA 3R 30 PROVIDE WITH 5% LINE REACTOR, INTERNAL EMI/RFI FILTER, INTERNAL DISCONNECT, CONNECT TO BUILDING DDC SYSTEM - -460 2.11460EF-8ACH 580ABB 0-70 YES YES NEMA 3R 30 VFD 7 VFD 8 VARIABLE FREQUENCY DRIVE SCHEDULE PROVIDE WITH 5% LINE REACTOR, INTERNAL EMI/RFI FILTER, INTERNAL DISCONNECT, CONNECT TO BUILDING DDC SYSTEM CHICAGO BLOWER DESIGN 38 CAST ALUMINUM BLOWER ROOF DESPATCH OVEN 900 150 6.5 9-3/4 x 2-7/8 3479 460 3 60 75- 1 EF 9 CHICAGO BLOWER DESIGN 38 CAST ALUMINUM BLOWER ROOF TOOL CLEAN SNORKEL 900 150 6.5 9-3/4 x 2-7/8 3479 460 3 60 75- 1 EF 10 CHICAGO BLOWER DESIGN 38 CAST ALUMINUM BLOWER ROOF ILT LASER 900 150 6.5 9-3/4 x 2-7/8 3479 460 3 60 75- 1 EF 11 CHICAGO BLOWER DESIGN 38 CAST ALUMINUM BLOWER ROOF EXTRUDER SNORKEL 900 150 6.5 9-3/4 x 2-7/8 3479 460 3 60 75- 1 - -460 2.11460EF-9ACH 580ABB 0-70 YES YES NEMA 3R 30VFD 9 PROVIDE WITH 5% LINE REACTOR, INTERNAL EMI/RFI FILTER, INTERNAL DISCONNECT, CONNECT TO BUILDING DDC SYSTEM - -460 2.11460EF-10ACH 580ABB 0-70 YES YES NEMA 3R 30VFD 10 PROVIDE WITH 5% LINE REACTOR, INTERNAL EMI/RFI FILTER, INTERNAL DISCONNECT, CONNECT TO BUILDING DDC SYSTEM - -460 2.11460EF-11ACH 580ABB 0-70 YES YES NEMA 3R 30VFD 11 PROVIDE WITH 5% LINE REACTOR, INTERNAL EMI/RFI FILTER, INTERNAL DISCONNECT, CONNECT TO BUILDING DDC SYSTEM WEIGHTMODEL NO.MANUFACTURERMARK LOCATION AREA SERVED PACKAGED ROOFTOP HEAT PUMP SCHEDULE FLA FAN CONDTONSMIN. O.A. H O)2 COMP.(IN. SP EXT. RLA ELECTRICAL FLA EVAP FAN PH.VOLT CYCLE SENS. HEATING OUTPUT (MBH)MAX. FUSEMCA KW INPUT HSPFCAP. (MBH) CAP.ENT. DB (°F) COOLING CAP. (°F) ENT. WB E.E.R.AMB. (°F)(LBS.) OPER. REMARKS CARRIER 50FCQM08A2A6-0A6A0 ROOF LAB 175 7.5 375 1.0 12.2 1.6 3 460 3 60 19 20 6.77 85.6 3.4 89.5 66.9 80 67 95 11.2 815 DISCONNECT BY ELECTRICAL, SIDE DISCHARGE, MOUNT ON EXISTING ROOF PAD, PROVIDE FACTORY ECONOMIZER WITH FAULT DETECTION & DIAGNOSTIC, PROVIDE DUCT SMOKE DETECTOR FOR AUTOMATIC SHUTOFF, PROVIDE FACTORY BACNET CONTROLLER AND CONNECT TO BUILDING DDC SYSTEM, 2" MERV-13 FILTER AC 9 CFM 3000 CARRIER 50GCQJ06A2A6-0A6A0 ROOF EXTRUSION 176 5 220 1.0 8.0 0.8 2.1 460 3 60 13 20 3.45 55.9 61.4 47.3 600 DISCONNECT BY ELECTRICAL, SIDE DISCHARGE, MOUNT ON EXISTING ROOF PAD, PROVIDE FACTORY ECONOMIZER WITH FAULT DETECTION & DIAGNOSTIC, PROVIDE DUCT SMOKE DETECTOR FOR AUTOMATIC SHUTOFF, PROVIDE FACTORY BACNET CONTROLLER AND CONNECT TO BUILDING DDC SYSTEM, 2" MERV-13 FILTER AC 10 2000 CARRIER 50GCQJ04A2A6-0A6A0 ROOF BRADING 178 3 200 1.0 4.7 0.6 1.2 460 3 60 8 15 2.34 34.3 36.6 28.1 500 DISCONNECT BY ELECTRICAL, SIDE DISCHARGE, MOUNT ON EXISTING ROOF PAD, PROVIDE FACTORY ECONOMIZER WITH FAULT DETECTION & DIAGNOSTIC, PROVIDE FACTORY BACNET CONTROLLER AND CONNECT TO BUILDING DDC SYSTEM, 2" MERV-13 FILTER AC 11 1200 CARRIER 50VR-K24---3 ROOF TOOL CLEAN ROOM 177 2 300 0.5 10.9 0.6 3.9 208 1 60 18.1 25 1.82 23.8 22.5 17.8 350 DISCONNECT BY ELECTRICAL, SIDE DISCHARGE, MOUNT ON EXISTING ROOF PAD, PROVIDE FACTORY BACNET CONTROLLER AND CONNECT TO BUILDING DDC SYSTEM, 2" MERV-13 FILTER AC 12 870 UPBLAST DISCHARGE, DIRECT DRIVE, CAST ALUMINUM CONSTRUCTION, MOUNT ON ROOF PAD, MANUAL VARIABLE SPEED CONTROL VIA WALL SWITCH SPEED CONTROLLER WIRED TO VFD REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 M0.2 MECHANICAL EQUIPMENT SCHEDULES COP - - 7.2 - 8.8 - 8.9 S.E.E.R. - - 17.0 - 15.2 80 67 95 80 67 95 80 67 95 - 17.0 UPBLAST DISCHARGE, DIRECT DRIVE, CAST ALUMINUM CONSTRUCTION, MOUNT ON ROOF PAD, MANUAL VARIABLE SPEED CONTROL VIA WALL SWITCH SPEED CONTROLLER WIRED TO VFD UPBLAST DISCHARGE, DIRECT DRIVE, CAST ALUMINUM CONSTRUCTION, MOUNT ON ROOF PAD, MANUAL VARIABLE SPEED CONTROL VIA WALL SWITCH SPEED CONTROLLER WIRED TO VFD UPBLAST DISCHARGE, DIRECT DRIVE, CAST ALUMINUM CONSTRUCTION, MOUNT ON ROOF PAD, MANUAL VARIABLE SPEED CONTROL VIA WALL SWITCH SPEED CONTROLLER WIRED TO VFD UPBLAST DISCHARGE, DIRECT DRIVE, CAST ALUMINUM CONSTRUCTION, MOUNT ON ROOF PAD, MANUAL VARIABLE SPEED CONTROL VIA WALL SWITCH SPEED CONTROLLER WIRED TO VFD EF 12 GREENHECK G-140-VG ROOF ELECTRICAL ROOM N/A 1500 0.375 N/A 1013 120 1 60 60- 1/2 CONTROLLED BY LINE VOLTAGE THERMOSTAT SET AT 85°F (ADJ.), DISCONNECT BY ELECTRICAL, MOUNT ON NEW ROOF CURB, CONNECT TO EXISTING BMS SYSTEM FOR MONITORING & ALARM 1 1 3009 S Daimler St 11/18/2024 1 2 3 4 7 8 5 5 S1 250 TYP. OF 12 S1 250 TYP. OF 8 S1 400 TYP. OF 3 S1 435 TYP. OF 2 R1 570 R1 600 TYP. OF 2 R1 890 TYP. OF 2 R1 875 TYP. OF 3 16"Ø 16"Ø16"Ø 18"Ø 10"Ø 10"Ø 10"Ø 10"Ø12"Ø12"Ø 14"Ø 10"Ø 10"Ø 10"Ø 10"Ø 12"Ø 12"Ø 20"Ø 10"Ø 10"Ø 12"Ø 10"Ø 10"Ø 12"Ø 4"Ø 4"Ø 4"Ø 6 6 56 6 10"Ø 10"Ø 10"Ø 10"Ø 10"Ø 10"Ø 12"Ø 14"Ø 10"Ø 10"Ø 10"Ø 12"Ø 14"Ø 12"Ø 14"Ø 16"Ø 16"Ø 10"Ø 10"Ø 14"Ø 14"Ø 10"Ø 10"Ø 10"Ø 16"Ø 16"Ø 14"Ø 14"Ø T AC-9 T AC-10 T AC-11 T AC-12 7 16"Ø 24"x10" TEF-12 9 10 11 12 13 13 C D E 1 2 3 4 MECHANICAL FIRST FLOOR PLAN01SCALE: 1/4" = 1'-0"NORTH 16"x10" SA & RA RISERS UP THROUGH ROOF. 18"x12" SA & RA RISERS UP THROUGH ROOF. 18"x18" SA & RA RISERS UP THROUGH ROOF. 20"x20" SA & RA RISERS UP THROUGH ROOF. 4"Ø EXHAUST DUCT DOWN THROUGH CEILING. TERMINATE 1' BELOW CEILING. FINAL CONNECTION TO BE FURNISHED AND INSTALLED BY OWNER. 4"Ø EXHAUST UP TO ROOF. 4"Ø EXHAUST DOWN TO NEW SNORKEL FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR. TERMINATE EXHAUST DUCT 1' BELOW CEILING. 6"Ø GALVANIZED SHEET METAL DOWN THROUGH CEILING. TERMINATE 2' ABOVE ACTIVE CARBON FILTER. FINAL CONNECTION TO BE FURNISHED AND INSTALLED BY OWNER. 24"x10" MAKEUP AIR DUCT UP TO ROOF. 24"x10" MAKEUP AIR DUCT DOWN TO 12" A.F.F. CUT AT 45° AND PROVIDE MESH SCREEN. 16"Ø EXHAUST DUCT UP TO EF-12 ON ROOF. 16"Ø EXHAUST DUCT OPEN AT END. CUT AT 45° AND PROVIDE MESH SCREEN. CONTRACTOR TO VERIFY AND INSTALL DUCT AS CLOSE TO ROOF AS POSSIBLE. 1 KEY NOTES: 1.CONTRACTOR SHALL VERIFY EXISTING LAYOUT IN FIELD. GENERAL NOTES: 2 3 4 5 6 7 REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 M1.1 MECHANICAL FIRST FLOOR PLAN 8 9 10 11 12 13 1 1 3009 S Daimler St 11/18/2024 EF 7 VFD 7 EF 11 VFD 11 EF 10 EF 8 EF 9 AC 9 AC 10 AC 11 AC 12 VFD 10 VFD 8 VFD 9 18 " x 1 2 " ( L ) 18 " x 1 2 " ( L ) 18 " x 1 8 " ( L ) 18 " x 1 8 " ( L ) 20 " x 2 0 " ( L ) 20 " x 2 0 " ( L ) 1 2 3 55 5 5 6 6 6 7 TYP. OF 3 7 7 8 8 8 8 4"Ø 4"Ø4"Ø 4"Ø 4"Ø 16 " x 1 0 " ( L ) 16 " x 1 0 " ( L ) 4 9 EF 12 1011 C D E 1 2 3 4 5 MECHANICAL ROOF PLAN01SCALE: 1/4" = 1'-0"NORTH 20"x20"(L) SA & RA RISERS DOWN. 18"x18"(L) SA & RA RISERS DOWN. 18"x12"(L) SA & RA RISERS DOWN. 16"x10"(L) SA & RA RISERS DOWN. 4"Ø EXHAUST DUCT DOWN. MINIMUM 25' CLEARANCE FROM OUTSIDE AIR INTAKES. DISCHARGE SHALL BE A MINIMUM OF 10' ABOVE ROOF. MOUNT UNIT ON EXISTING ROOF PAD. 6"Ø GALVANIZED SHEET METAL EXHAUST VENT. PROVIDE VENT CAP. 24"x10" MAKEUP AIR DUCT INLET. CUT AT 45° AND PROVIDE MESH SCREEN. PROVIDE BACKDRAFT DAMPER. 24"x10" MAKEUP AIR DUCT DOWN TO 1ST FLOOR. 1 KEY NOTES: 1.CONTRACTOR SHALL VERIFY EXISTING ROOF LAYOUT IN FIELD. GENERAL NOTES: 2 3 4 5 6 7 8 M1.2 MECHANICAL ROOF PLAN REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 9 10 11 1 1 3009 S Daimler St 11/18/2024 NO SCALE M2.1 1 NO SCALE M2.1 2 NO SCALE M2.1 3 NO SCALE M2.1 4 NO SCALE M2.1 5 NO SCALE M2.1 6 NO SCALE M2.1 7 NO SCALE M2.1 8 GALVANIZED UNISTRUT SUPPORT AS NEEDED BY VFD MANUFACTURER VFD AS SHOWN ON FLOOR PLAN FREE STANDING GALVANIZED UNISTRUT MOUNTED @ ROOF LEVEL ANCHORS PER STRUCTURAL SEISMIC GALVANIZED UNISTRUT BRACING (TYP) ADJUSTABLE HINGE ROOF MOUNTED UNIT VFD CONTROL PANEL MOUNTING DETAIL COUNTER FLASHING ROOF FLASHING CAN'T STRIP CONTINUOUS WELD OR CLAMP WITH SEALANT DUCT LINER ROOFING DUCT FLOOR OPENING DUCT SIZE +2" DUCT PENETRATION AT ROOF DETAIL CAN'T STRIP DUCT RISER ROOFING CURB FLASHING FORM WATER-TIGHT CONNECTION DUCT PENETRATION (ROUND) AT ROOF DETAIL 3'-0" MAX THIS DIMENSION MUST BE AT LEAST 1/2 "D" "D" 30° OR LESS (TYPICAL) DUCT UNDER BEAM OR CROSSOVER SECTION NO SCALE BRANCH DUCT 45° MAIN "D" 4 "D" RECTANGULAR BRANCH DUCT NO SCALE BRANCH FLEX OR SPIRAL DUCT MANUAL VOLUME DAMPER ON FITTING (TYPICAL) 45° MAIN ROUND BRANCH DUCT NO SCALE RECTANGULAR MAIN/ROUND BRANCH DUCT NO SCALE ROUND BRANCH FLEX DUCT OR SPIRAL DUCT MANUAL VOLUME DAMPER (RECTANGULAR) MAIN DUCT SADDLE TAP OR SPIN-IN FITTING 45° TYPICAL DUCT TAKEOFF DETAILS HANGER STRAPS MA X I M U M S P A C I N G SCREWS SLING, AVOID DISRUPTION OF INSULATION BAND OF SAME SIZE AS HANGER STRAP HANGER STRAP LOAD-RATED FASTENERS 12 " 12 " 3" 1" MIN 12 " ROUND DUCT RECTANGULAR DUCT SYSMIC SUPPORT (TYPICAL) DUCT SUPPORT DETAIL CURB FLASHING 10'-0" MIN. USE BRACING CABLES TO ROOF AS REQUIRED IF DUCT IS 8'-0" OR LONGER EXHAUST FAN WITH WEATHER PROOF HOUSING ISOLATION VIBRATION (TYP.) BOLT INTO ROOF STRUCTURAL MEMBER PAD, SEE STRUCTURAL EXHAUST DUCT 3Ø MIN. LENGTH STACK BY MECHANICAL CONTRACTOR FLEXIBLE CONNECTION UTILITY EXHAUST FAN DETAIL MECHANICAL EQUIPMENT PLATFORM DETAIL OUTSIDE AIR INTAKE W. M.V.D. & 1/4"x1/4" MESH SCREEN FLEXIBLE CONNECTOR 1 PROVIDE DUCT MOUNTED SMOKE DETECTORS FOR UNITS GREATER THAN 2000 CFM 1 SUPPLY & RETURN LINED DUCT WORK ROOFTOP HEAT PUMP (HORIZONTAL) DETAIL (E)PLATFORM BASE OF MECHANICAL UNIT (E)ROOF STRUCTURE (E)ROOFING SPRING VIBRATION ISOLATOR WITH SEISMIC RESTRAINT NEOPRENE ISOLATOR PADS M2.1 MECHANICAL DETAILS REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 NO SCALE M2.1 9 12GA WIRE ATTACHED TO OPPOSING CORNERS, CONNECT TO STRUCTURAL CEILING (TYP), WIRES MAY BE SLACK FLEXIBLE DUCT NOT TO EXCEED 5'-0" WHEN FULLY EXTENDED ATTACH RIGID DUCT TO FLEX DUCT WITH MINIMUM 2" WIDE STRAP (TYP) DIFFUSER ROUND DUCT MANUAL AIR VOLUME DAMPER (TYP) ROD CONTINUOUS ON ALL DAMPERS OVER 12" DIAMETER CONNECT TO STRUCTURAL (TYP) CONNECT RIGID DUCT TO FLEX DUCT WITH MINIMUM 1" WIDE STRAP (TYP) DAMPER ARM WITH QUADRANT LOCK ACOUSTIC CEILING TILE SHOWN. SEE DIFFUSER MANUFACTUER INFORMATION FOR GYP. BOARD CEILING INFORMATION T-RUNNER (TYP) SECURE WITH (4) #10 SCREWS FLEX DUXT BEND RADIUS SHALL BE 2 TIMES THE DUCT RADIUS DIFFUSER DETAIL 3009 S Daimler St 11/18/2024 NO SCALE M2.2 1 NO SCALE M2.2 2 T-RUNNER (TYP) ACOUSTIC CEILING TILE SHOWN. SEE DIFFUSER MANUFACTUER INFORMATION FOR GYP. BOARD CEILING INFORMATION FLEX DUXT BEND RADIUS SHALL BE 2 TIMES THE DUCT RADIUS 3"MIN. DUCT SIZE PER FLOOR PLANS RETURN AIR TO CEILING PLENUM CONNECT TO STRUCTURE (TYP) 12GA. WIRE ATTACHED TO OPPOSING CORNERS, CONNECT TO STRUCTURAL CEILING (TYP), WIRS MAY BE SLACK FLEXIBLE DUCT NOT TO EXCEED 5'-0" ATTACH FLEX DUCT TO STRUCTURAL W/MIN. 2" WIDE STRAP (TYP) RETURN AIR GRILL DETAIL TOP OF THERMOSTAT FINISHED FLOOR 46" MAX 34" MAX 24" MAX T OVER OBSTRUCTIONMOUNTING HEIGHT T CENTERLINE OF THERMOSTAT FINISHED FLOOR 48" MAX ACCESS NOTE: THERMOSTATS ARE TO BE LOCATED NO MORE THAN 48" ABOVE FINISHED FLOOR (46" MAXIMUM HEIGHT IF LOCATED OVER A COUNTER) (24" MAXIMUM REACH DEPTH AT COUNTER) COORDINATE WITH ARCHITECTURAL DRAWING THERMOSTAT MOUNTING DETAIL M2.2 MECHANICAL DETAILS REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 AC-9 OUTSIDE AIR RETURN AIR SUPPLY AIR 3,000CFM LAB 175 AREA = 2,460 SQ. FT. VOLUME = 26,635 CU. FT. MINIMUM ACH = N/A EXTRUSION ROOM 176 MINIMUM ACH = N/A BRAIDING ROOM 178 AREA = 650 SQ. FT. VOLUME = 7,150 CU. FT. TOOL CLEAN ROOM 177 AREA = 185 SQ. FT. VOLUME = 2,035CU. FT. EXHAUST 450 CFM DELIVERED ACH = 6.8 AREA = 1,385 SQ. FT. VOLUME = 15,235 CU. FT. DELIVERED ACH = 7.9 MINIMUM ACH = N/A DELIVERED ACH = 10.0 MINIMUM ACH = N/A DELIVERED ACH = 25.8 2,550 CFM AC-10 OUTSIDE AIR RETURN AIR SUPPLY AIR 2,000 CFMEXHAUST 150 CFM 1,850 CFM AC-11 OUTSIDE AIR RETURN AIR SUPPLY AIR 1,200 CFM1,050 CFM AC-11 OUTSIDE AIR RETURN AIR SUPPLY AIR 875 CFM675 CFMEXHAUST 200 CFM NO SCALE M2.2 3AIRFLOW DIAGRAM 3009 S Daimler St 11/18/2024 M MAO - Mixed Air Dampers OA RA DA T AI - Zone Temp AI - Zone Setpoint Adjust BI - Zone Override M CT BO - Fan Start/Stop BI - Fan Status T AI - Discharge Air Temp BI - Smoke Detector HP BO - Compressor Stage 1 BO - Reversing Valve N.O. N.C. This variable frequency drive (vfd) interface schematic may not reflect the actual sensors and points as supplied by the vfd manufacturer. All interface points shall be coordinated with the vfd supplier. VFD AV - Motor Speed RPM AV - Motor Frequency Hz AV - Motor Current Amps AV - Motor Runtime BV - VFD Status BV - In Fault Condition BV - In Bypass NO SCALE M3.1 1HEAT PUMP CONTROLS DIAGRAMS NO SCALE M3.1 2VFD CONTROLS DIAGRAMS REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 M3.1 MECHANICAL CONTROL DIAGRAMS 3009 S Daimler St 11/18/2024 REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 M4.1 MECHANICAL T24 DOCUMENTATION 3009 S Daimler St 11/18/2024 LE A V E B L A N K F O R C I T Y S T A M P SYMBOL ABBREVIATION DESCRIPTION PLUMBING LEGEND POC S S CD V DCW TP CA RPBP SOV CV COG FCO WCO CL # % DN UP WHB HB U WHA TP FS FD PLUMBING GENERAL NOTES NOTE:GENERAL NOTES ARE LISTED FOR GENERAL USE; NOT ALL LISTED ARE NECESSARILY USED ON DRAWINGS. GENERAL: 1.CONTRACTOR SHALL CAREFULLY REVIEW THESE PLANS AND SPECIFICATIONS PRIOR TO BID. CONTRACTOR SHALL ALSO REVIEW PLANS AND SPECIFICATIONS OF OTHER RELATED TRADES (INCLUDING ARCHITECTURAL, MECHANICAL, STRUCTURAL, CIVIL AND ELECTRICAL) PRIOR TO BID TO INSURE AN ACCURATE UNDERSTANDING OF EXACT SCOPE OF WORK. 2.EQUIPMENT INDICATED ON THESE DRAWINGS IS SHOWN IN APPROXIMATE LOCATIONS. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS INCLUDING EQUIPMENT LOCATIONS, STRUCTURAL MEMBERS, POC'S, INVERT ELEVATIONS AND AVAILABILITY OF ALL EXISTING UTILITIES PRIOR TO INSTALLATION. NOTIFY THE CONSTRUCTION COORDINATOR OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO COMMENCING ANY WORK. DO NOT PROCEED WITHOUT CONSTRUCTION COORDINATOR APPROVAL FOR ANY CHANGES IF REQUIRED. 3.PLUMBING EQUIPMENT, MATERIAL AND CONNECTIONS SHALL BE INSTALLED COMPLETE PER MANUFACTURER'S INSTRUCTIONS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL SYSTEM. 4.WORK SHALL CONFORM TO CODE. IN CASE OF CONFLICTS WITH CODE, DRAWINGS, OR SPECIFICATIONS, THE MORE STRINGENT SHALL PREVAIL. 5.PLUMBING SHALL BE INSTALLED TO AVOID INTERFERENCE WITH ELECTRICAL AND MECHANICAL EQUIPMENT AND STRUCTURAL FRAMING. COORDINATE WITH ALL OTHER TRADES, STRUCTURAL CONDITIONS AND BUILDING CONSTRUCTION, PRIOR TO START OF INSTALLATION. 6.PLUMBING WORK SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO AS GREAT EXTENT AS POSSIBLE. 7.PIPING SYSTEMS SHALL BE SEISMICALLY BRACED PER CALIFORNIA BUILDING CODE. 8.VALVES SHALL BE READILY ACCESSIBLE. WHERE VALVES ARE INSTALLED WITHIN OR BEHIND WALLS, AN ACCESS PANEL SHALL BE INSTALLED. 9.OUTLETS FOR FUTURE CONNECTIONS SHALL BE INSTALLED TO PERMIT EASY CONNECTION. COORDINATE WITH DUCTWORK, STRUCTURAL CONDITIONS AND ARCHITECTURAL LAYOUT. 10.INSULATING MATERIALS INSTALLED SHALL BE CERTIFIED BY CALIFORNIA ENERGY COMMISSION TO MEET C.E.C. ENERGY EFFICIENCY STANDARDS (E.E.S) SECTION 110.3. 11.PLUMBING EQUIPMENT SHALL BE CERTIFIED BY AND COMPLY WITH THE STATE OF CALIFORNIA ENERGY CONSERVATION STANDARDS (E.E.S.) SECTION 110.3. COMPLIANCE CERTIFICATES SHALL BE PROVIDED WITH EQUIPMENT SUBMITTALS. 12.DO NOT ROUTE PIPING OVER ELECTRICAL ROOMS, MDF ROOMS, IDF ROOMS, COMPUTER ROOMS, ELEVATOR EQUIPMENT ROOMS, OR STAIRWELLS. EXCEPTION: PIPES REQUIRED TO SERVE THE ROOM. 13.ALL PIPE, PIPE FITTINGS, TRAPS, FIXTURES, MATERIAL, AND DEVICES USED IN THE PLUMBING SYSTEM SHALL BE LISTED OR THIRD-PARTY CERTIFIED BY AN APPROVED LISTING AGENCY AND SHALL CONFORM TO APPLICABLE RECOGNIZED STANDARDS REFERENCED IN THE 2022 CALIFORNIA PLUMBING CODE. 14.THE LEAD CONTENT OF PIPES, PIPE OR PLUMBING FITTINGS, AND FIXTURES INTENDED TO CONVEY OR DISPENSE WATER FOR HUMAN CONSUMPTION SHALL BE IN ACCORDANCE WITH SECTION 116875 OF THE HEALTH AND SAFETY CODE. DRAINAGE: 1.COORDINATE LOCATION OF CONDENSATE DRAIN AND WATER CONNECTIONS TO MECHANICAL EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO INSTALLATION. 2.ALL INTERIOR CONDENSATE DRAIN PIPING SHALL BE INSULATED AND SLOPED AT 1/8" PER FOOT MINIMUM. 3.CONDENSATE FROM ALL MECHANICAL COOLING COILS SHALL BE ROUTED AND DISCHARGED TO AN APPROVED RECEPTOR PER THE CALIFORNIA PLUMBING CODE. 4.BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH SECTIONS 701.0 AND 903.0 OF THE CALIFORNIA PLUMBING CODE. 5.ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTING AGENCY. 6.CLEANOUTS ARE REQUIRED AT THE UPPER MOST TERMINALS OF ALL HORIZONAL WASTE LINES. PLEASE PROVIDE ADDITIONAL CLEANOUTS WITHIN THE FLOOR PLAN. CPC 707.4. 7.EACH VENT SHALL RISE VERTICALLY TO A POINT NOT LESS THAN SIX (6) INCHES ABOVE THE FLOOD-LEVEL RIM OF THE FIXTURE SERVED BEFORE OFFSETTING HORIZONTALLY OR BEFORE BEING CONNECTED TO ANY OTHER VENT. 8.EACH ROOF VENT SHALL TERMINATE AT LEAST 10 FT FROM EVERY BUILDING OUTSIDE AIR INTAKE. 9.SOIL, SEWER AND WASTE PIPING SHALL SLOPE AT 1/4" PER FOOT MINIMUM UNLESS INDICATED OTHERWISE. 10.A SLOPE OF NOT LESS THAN 1/8 INCH PER FOOT OR 1 PERCENT IS PROVIDED FOR DRAINAGE PIPING 4 INCHES OR LARGER ONLY WHERE IT IS IMPRACTICAL DUE TO THE DEPTH OF THE STREET SEWER, TO THE STRUCTURAL FEATURES, OR TO THE ARRANGEMENT OF A BUILDING OR STRUCTURE TO OBTAIN A SLOPE OF 1/4 INCH PER FOOT OR 2 PERCENT AND THAT IS SUBJECT TO THE AUTHORITY HAVING JURISDICTION PLUMBING FIELD INSPECTOR'S APPROVAL. PLUMBING FIXTURES: 1.EXACT LOCATION AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS. 2.FLOOR DRAINS OR SIMILAR TRAPS DIRECTLY CONNECTED TO THE DRAINAGE SYSTEM AND SUBJECT TO INFREQUENT USE SHALL BE PROVIDED WITH AN APPROVED AUTOMATIC MEANS OF MAINTAINING THEIR WATER SEALS. 3.FLOOR AND TRENCH DRAINS SHALL BE IN ACCORDANCE WITH ASME A112.6.3. 4.FLOOR SINKS SHALL BE IN ACCORDANCE WITH ASME A112.6.7. 5.TRAP SEAL PRIMERS FOR POTABLE WATER SUPPLY SHALL BE IN ACCORDANCE WITH ASSE 1018. DRAINAGE AND ELECTRONIC DESIGN TYPE TRAP SEAL PRIMER DEVICES SHALL COMPLY WITH ASSE 1044. TRAP PRIMERS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION FOR MAINTENANCE. 6.ROOF RECEPTORS ARE PLUMBING FIXTURES THAT ARE LISTED BY IAPMO AS INDIRECT WASTE RECEPTORS. CROSS CONNECTION CONTROL: 1.CROSS CONNECTION PROTECTION SHALL BE PROVIDED AT ALL POTABLE WATER SUPPLIED APPLIANCES AND EQUIPMENT. ABOVE CEILING AMERICANS WITH DISABILITIES ACT ABOVE FINISHED FLOOR BELOW GRADE BELOW FLOOR BELOW FINISHED FLOOR BUILDING BRITISH THERMAL UNITS PER HOUR CALIFORNIA BUILDING CODE CUBIC FEET PER HOUR CUBIC FEET PER MINUTE CLEANOUT CALIFORNIA PLUMBING CODE DRAINAGE FIXTURE UNITS DRAWINGS EXISTING ENERGY EFFICIENCY STANDARDS FLOOR CLEANOUT FEET FEET/SECOND FIXTURE UNIT GAUGE GALLONS PER CYCLE GALLONS PER DAY GALLONS PER FLUSH GALLONS PER HOUR GALLONS PER MINUTE HORSE POWER HEATING, VENTILATING, & AIR CONDITIONING INVERT ELEVATION INCH/INCHES POUNDS MAXIMUM MECHANICAL MANUFACTURER'S MINIMUM NORMALLY CLOSED NORMALLY OPEN OWNER FURNISHED CONTRACTOR INSTALLED OWNER FURNISHED OWNER INSTALLED QUICK CONNECT PRESSURIZED DISCHARGE (PUMPED) PLUMBING QUANTITY SQUARE FEET STATIC PRESSURE TONNAGE OF AIR CONDITIONING TOTAL DRAINAGE FIXTURE UNITS TOTAL DEVELOPED LENGTH TOTAL FIXTURE UNITS TYPICAL VARIABLE FREQUENCY DRIVE VERIFY IN FIELD VENT THRU ROOF VOLTS/PHASE/HERTZ WALL CLEAN-OUT UNDERWRITERS LABORATORY WATER SUPPLY FIXTURE UNITS A/C ADA AFF B/G B/F BFF BLDG BTUH CBC CFH CFM CO CPC DFU DWGS (E) E.E.S. FCO FT FPS FU GA GPC GPD GPF GPH GPM HP HVAC IE IN LBS MAX MECH MFR'S MIN N.C. N.O. OFCI OFOI QC PD PLBG QTY SF SP T TDFU TDL TFU TYP VFD VIF VTR V/PH/HZ WCO UL WSFU POINT OF CONNECTION SEWER PIPING UNDERGROUND / BELOW FLOOR SEWER PIPING ABOVE GROUND CONDENSATE DRAIN PIPING SANITARY VENT PIPING DOMESTIC COLD WATER PIPING TRAP PRIMER PIPING COMPRESSED AIR PIPING BACKFLOW PREVENTER SHUT OFF VALVE (BALL VALVE) CHECK VALVE CLEAN-OUT TO GRADE PRESSURE REGULATOR VALVE FLOOR CLEAN-OUT WALL CLEAN-OUT CAPPED LINE PERCENTAGE SLOPE OF PIPE WITH DIRECTIONAL ARROW DOWN OR DROP RISE OR RISER WALL HOSE BIBB HOSE BIBB UNION (DIELECTRIC) WATER HAMMER ARRESTOR (P.D.I. SIZE) TRAP PRIMER FLOOR SINK FLOOR DRAIN KEYED NOTE TYPE/MARK EQUIPMENT NUMBER EQUIPMENT TAG NOTE: LEGEND AND ABBREVIATIONS LISTED ARE FOR GENERAL USE; NOT ALL LISTED ARE NECESSARILY USED ON DRAWINGS.PIPE MATERIAL SCHEDULE SEWER WASTE & VENT PIPING BELOW GRADE: CHARLOTTE CHEMDRAIN SCHEDULE 40 CPVC WITH SOLVENT WELDED SOCKET FITTINGS. SEWER WASTE & VENT PIPING ABOVE GRADE: CHARLOTTE CHEMDRAIN SCHEDULE 40 CPVC WITH SOLVENT WELDED SOCKET FITTINGS. WATER PIPING ABOVE GRADE: COPPER TYPE "L", HARD DRAWN, WITH LEAD-FREE SOLDER. WATER PIPING BELOW GRADE: COPPER TYPE "K", HARD DRAWN, WITH LEAD-FREE SOLDER. CONDENSATE DRAIN ABOVE GRADE: COPPER TYPE "M", WITH LEAD - FREE SOLDER. INSULATED. COMPRESSED AIR ABOVE GRADE: 316 STANLESS STEEL, CLEANED, PURGED AND SEALED FOR OXYGEN SERVICE. WITH SWAGELOK FITTINGS. ALL PIPING TO BE LABELED PER ANSI/ASME A13.1 STANDARD COLOR AND LETTER REQUIREMENTS. ALL PIPING SHALL HAVE HANGERS AND SUPPORTS SPACED IN ACCORDANCE WITH CPC TABLE 313.3 AND HANGER RODS IN ACCORDANCE WITH CPC 313.6. FITTINGS FOR CHANGES IN DIRECTION WYE WYE WITH 1/8 BEND COMB. 1/8 BEND SANIT. TEE SANIT. TAPPED TEE LONG SWEEP SHORT SWEEP 1/8 BEND 1/6 BEND TYPE OF FITTING CHANGES IN DIRECTION OF FLOW HORIZONTAL TO VERTICAL VERTICAL TO HORIZONTAL HORIZONTAL TO HORIZONTAL *BASED ON 2018 UNIFORM PLUMBING CODE ILLUSTRATED TRAINING MANUAL, FIGURE 706.1 ENERGY CONSERVATION NOTES 1.EQUIPMENT SHALL MEET THE APPLICABLE REQUIREMENTS OF THE APPLIANCE EFFICIENCY REGULATIONS PER SECTION 110.1. 2.ALL PIPE INSULATION MATERIAL SHALL MEET THE REQUIREMENTS PER SECTION 120.3 E.E.S. SYMBOL DESCRIPTION PIPE SIZES (INCHES) CW REMARKS FIXTURE CONNECTION SCHEDULE MANUFACTURER AND MODEL NUMBER --------1/2 PPP #PR-500TP-1 TRAP PRIMER PRESSURE ACTIVATED. PROVIDE WITH DISTRIBUTION UNIT AND ACCESS PANEL. FLOOR SINKFS-1 1/2 --2 2 --ZURN #Z1750-2 STAINLESS STEEL FLOOR SINK. PROVIDE W/ TRAP PRIMER CONNECTION. HW W V CA ELECTRICAL (V/PH/HZ) -- -- 2% 1% TP CD CA # PRV PIPE, PIPE FITTINGS, VALVES AND FIXTURES INTENDED TO CONVEY OR DISPENSE WATER FOR HUMAN CONSUMPTION THROUGH DRINKING OR COOKING, SHALL BE CERTIFIED TO BE "LEAD FREE" AS DEFINED BY STATUTE AB 1953. NOTHING CONTAINED IN THESE DRAWINGS OR SPECIFICATIONS IS INTENDED TO VIOLATE THIS STATUTE. AB 1953 COMPLIANCE PLUMBING EXISTING AND DEMOLITION NOTES TO CONTRACTOR 1.CONTRACTOR SHALL NOT CUT, DRILL, OR ALTER ANY STRUCTURAL SUPPORT MEMBER WITHOUT WRITTEN APPROVAL BY THE STRUCTURAL ENGINEER. 2.CONTRACTOR SHALL FIELD VERIFY EXISTING PIPE SIZES AND ELEVATIONS AT ALL POINTS OF CONNECTION PRIOR TO PROCUREMENT OF MATERIALS AND INSTALLATIONS. 3.CONTRACTOR SHALL PERFORM CAMERA INSPECTION OF PIPING AND HYDRO-JET ALL ABOVE AND BELOW GRADE SEWER, WASTE & VENT PIPING TO ENSURE INTEGRITY OF INTERIOR OF PIPING SYSTEM AND SLOPE . REPAIR ALL DAMAGED PORTION OF PIPING SYSTEM TO REMOVE ALL OBSTRUCTIONS. 4.CONTRACTOR SHALL X-RAY SLAB TO IDENTIFY STRUCTURAL COMPONENTS PRIOR TO CORE DRILLING AND / OR SAW-CUTTING SLAB. 5.ALL EXISTING PLUMBING COMPONENTS THAT ARE INTENDED TO REMAIN FOR REUSE SHALL BE PROTECTED DURING CONSTRUCTION. 6.ALL EXISTING PLUMBING FIXTURES COSMETIC APPEARANCE AND FUNCTIONAL CONDITIONS SHALL BE VERIFIED TO ENSURE COMPLIANCE WITH CURRENT FLOW AND CLEARANCE REQUIREMENTS. 7.CONTRACTOR SHALL SAW-CUT AND DEMOLISH EXISTING SLAB, EXCAVATION AS REQUIRED TO INSTALL NEW UNDERGROUND PIPING. PROVIDE BACKFILL, COMPACTION AND CONCRETE POURING / FINISHING AS REQUIRED IN COORDINATION WITH GENERAL CONTRACTOR. 1/2--------AMFLO #C-30 #C-31LAO-1 LAB AIR OUTLET (QUICK CONNECT)INSTALL PER MANUFACTURER'S INSTRUCTIONS.-- -- 2 TRAP -- REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 P0.1 PLUMBING GENERAL NOTES, LEGENDS & SCHEDULES MARK GALLON CAPACITY ELECTRICAL DATA VOLT HP REMARKS WF 1 -------- EQUIPMENT SCHEDULE ---- PH.CYCLE WATTS AMPS MANUFACTURER MODEL NO. CULLIGAN #MS040954 #MS004499 -INSTALL PER MANUFACTURER'S INSTRUCTIONS. DESCRIPTION WATER FILTER --------3/4 ACORN #8126-LFHB-1 HOSE BIBB PROVIDE WITH VACUUM BREAKER.---- 1--------SMC #AR50-N10E-Z-DCA-PRV-1 LAB AIR PRESSURE REGULATOR WITH GAUGE PRESSURE REGULATOR WITH PRESSURE GAUGE. INSTALL PER MANUFACTURER'S INSTRUCTIONS.---- 3009 S Daimler St 11/18/2024 (E)4"S (E)4"S (E)4"S SL O P E @ 2 % SL O P E @ 2 % TP-1 FS-1 FS-1 2"S SLOPE @ 2% (E)FCO 1 1 1 SLOPE @ 2% SLOPE @ 2% 2"S 2"S 2"V, B/G 2"V, UP 2"VTR 2"V, B/G 2"VTR 2"V, B/G 2"VTR(E)2"DCW(E)2"DCW 2 SOV 3 3/4"DCW TP-1 TP-1 3/4"DCW 3/4"DCW 4 4 4 FS-1 SL O P E @ 2 % SLOPE @ 2% SL O P E @ 2 % 3/4"DCW, DN 2"V, UP 5 5 5 3/4"DCW, DN 3/4"DCW, UP SOV SOV 1 WF6 3/4"DCW 3/4"DCW 3/4"DCW, UP SOV 2"S FCO FCO FCO 7 3/4"DCW 1"CD, UP SL O P E @ 1 % 1"CD, DN (E)FLOOR SINK 8 C D E 1 2 3 4 PLUMBING FIRST FLOOR PLAN01SCALE: 1/4" = 1'-0"NORTH POC 2" SANITARY SEWER TO EXISTING PIPE. POC 3/4" COLD WATER TO EXISTING PIPE. 3/4" COLD WATER TO EQUIPMENT #94 WITH SHUT OFF VALVE. TRAP PRIMER BEHIND ACCESS PANEL, SEE DETAIL 5/P2.1. FLOOR SINK, REFER TO DETAIL 5/P2.1. WATER FILTER TO BE MOUNTED ON WALL AT 4 FEET AFF. PROVIDE SHUT OFF VALVE IN WALL AT 5 FEET AFF WITH WALL ACCESS PANEL AND PAINT TO MATCH ARCHITECTURE FINISH. ACCESS PANEL TO FACE THE CORRIDOR. 1" CONDENSATE DRAIN DISCHARGE AT EXISTING FLOOR SINK. SEE DETAIL 8/P2.1. 1 KEY NOTES: 1.CONTRACTOR TO FIELD VERIFY SIZE AND LOCATION OF ALL PLUMBING FIXTURES, PIPING, HANGERS, SUPPORTS AND ACCESSORIES PRIOR TO COMMENCEMENT OF WORK. 2.CONTRACTOR SHALL FIELD VERIFY EXISTING PIPE SIZES AND ELEVATIONS AT ALL POINTS OF CONNECTION PRIOR TO PROCUREMENT OF MATERIAL AND INSTALLATION. 3.FOR PIPE TRAPEZE AND HANGER PIPE DETAILS, 3&4/P2.1. GENERAL NOTES: 2 3 4 REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 P1.1 PLUMBING 1ST FLOOR PLAN 5 6 7 8 3009 S Daimler St 11/18/2024 (E)2"CA 1 1"CA (E)2"CA 3/4"CA 1/2"CA 1/2"CA 3 4 1/2"CA 9 1/2"CA 9 9 9 1/2"CA1/2"CA 1/2"CA 9 1/2"CA 5 9 9 1/2"CA 1/2"CA 1/2"CA 6 7 1"CA 1"CA 1"CA 1"CA1"CA 1"CA 1"CA 1"CA (E)2"CA (E)2"CA 3/4"CA 3/4"CA 99 9 9 1/2"CA 1/2"CA 99 9 9 3/4"CA3/4"CA 99 9 9 1/2"CA 1/2"CA 99 9 9 1/2"CA 991/2"CA1/2"CA 991/2"CA 9 9 1/2"CA 9 9 1/2"CA LAO-1 LAO-1 LAO-1 9 LAO-1 LAO-1 LAO-1 LAO-1LAO-1LAO-1LAO-1 LAO-1 LAO-1 LAO-1 LAO-1 LAO-1 LAO-1 LAO-1 LAO-1LAO-1 LAO-1 LAO-1 LAO-1 LAO-1 LAO-1 LAO-1 LAO-1 LAO-1LAO-1 LAO-1 LAO-1LAO-1LAO-1 1/2"CA 1"CA 1"CA1"CA 1/2"CA 1/2"CA 9 LAO-11/2"CA 9LAO-1 3/4"CA CA-HV1000 CA-PRV10002 1/2"CA 1/2"CA1/2"CA 1/2"CA1/2"CA1/2"CA 1/2"CA LAO-1 LAO-1 LAO-1 LAO-1 LAO-1 CA-PRV-1 10 C D E 1 2 3 4 PLUMBING FIRST FLOOR PLAN - COMPRESSED AIR01SCALE: 1/4" = 1'-0"NORTH POC 1" COMPRESSED AIR TO EXISTING PIPE. PROVIDE PRESSURE REGULATOR WITH PRESSURE GAUGE AND SHUT OFF VALVE AT 4 FEET AFF. SET PRESSURE REGULATOR AT 110 PSI. 1/2" COMPRESSED AIR DOWN AND STUB OUT WITH QUICK DISCONNECT VALVE AT 4 FEET AFF FOR EQUIPMENT #5. 1/2" COMPRESSED AIR DOWN AND STUB OUT WITH QUICK DISCONNECT VALVE AT 4 FEET AFF FOR EQUIPMENT #6. 1/2" COMPRESSED AIR DOWN AND STUB OUT WITH QUICK DISCONNECT VALVE AT 4 FEET AFF FOR EQUIPMENT #49. 1/2" COMPRESSED AIR DOWN AND STUB OUT WITH QUICK DISCONNECT VALVE AT 4 FEET AFF FOR EQUIPMENT #99. 1/2" COMPRESSED AIR DOWN AND STUB OUT WITH QUICK DISCONNECT VALVE AT 4 FEET AFF FOR EQUIPMENT #37. 1/2" COMPRESSED AIR TO UTILITY CEILING TILE WITH QUICK DISCONNECT VALVE. PROVIDE DIRT LEG WITH SHUT OFF VALVE. 1 KEY NOTES: 1.CONTRACTOR TO FIELD VERIFY SIZE AND LOCATION OF ALL PLUMBING FIXTURES, PIPING, HANGERS, SUPPORTS AND ACCESSORIES PRIOR TO COMMENCEMENT OF WORK. 2.FOR COMPRESSED AIR BRANCH DETAIL, SEE 1/P2.1. 3.FOR PIPE TRAPEZE AND HANGER PIPE DETAILS, 3&4/P2.1. 4.FOR COMPRESSED AIR RISER DIAGRAM, SEE 1&2/P1.4. GENERAL NOTES: 2 3 4 5 6 7 9 REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 P1.2 PLUMBING 1ST FLOOR PLAN - COMPRESSED AIR 10 3009 S Daimler St 11/18/2024 2"VTR 2"VTR 1"CD, DN 1"CD (17.5 T) 1 3/4"CD (7.5 T) AC-9 AC-12 AC-10 AC-11 1 1 3/4"CD (3 T) 3/4"CD (2 T) 2"VTR HB-1 3/4"DCW, DN 2 3 3 1 3/4"CD (5 T) 3/4"CD (15.5 T) 3/4"CD (8 T)SL O P E @ 1 % C D E 1 2 3 4 PLUMBING ROOF PLAN01SCALE: 1/4" = 1'-0"NORTH FOR CONDENSATE DRAIN DETAIL, SEE 2/P2.1. PROVIDE HOSE BIBB AT 12" ABOVE ROOF. CONDENSATE PIPE TO BE PAINTED WITH EPOXY YELLOW FOR PIPE RUNNING EXPOSED OVER WALKING PADS. 1 KEY NOTES: 1.CONTRACTOR TO FIELD VERIFY SIZE AND LOCATION OF ALL PLUMBING FIXTURES, PIPING, HANGERS, SUPPORTS AND ACCESSORIES PRIOR TO COMMENCEMENT OF WORK. 2.FOR VENT THRU ROOF DETAIL, SEE 6/P2.1. 3.FOR PIPE SUPPORT ON ROOF DETAIL, SEE 7/P2.1. GENERAL NOTES: 2 REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 P1.3 PLUMBING ROOF PLAN 3 3009 S Daimler St 11/18/2024 ROOF LEVEL 1 (E)2"CA (E)2"CA (E)2"CA POC 1" COMPRESSED AIR TO EXISTING. UTILITY CEILING PANEL, TYP. 1"CA 1"CA 1"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA EQUIPMENT #99 1/2"CA EQUIPMENT #48 3/4"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA EQUIPMENT #37 1/2"CA 3/4"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA EQUIPMENT #49 1/2"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA EQUIPMENT #25 EQUIPMENT #88 EQUIPMENT #89 1/2"CA 1/2"CA EQUIPMENT #11 1/2"CA 1/2"CA 1/2"CA EQUIPMENT #6 MA T C H L I N E 2/ P 1 . 4 1/ P 1 . 4 1"CA 1"CA 1"CA 1"CA SOV CA-HV1000 CA-PRV-1 CA-PRV1000 SET AT 110 PSI LAO-1 LAO-1 LAO-1 LAO-1 LAO-1 TABLETOPTABLETOPTABLETOPTABLETOP LAO-1 LAO-1 TABLETOP LAO-1 TABLETOP LAO-1 TABLETOP LAO-1 TABLETOP EQUIPMENT #48 LAO-1 LAO-1 LAO-1 LAO-1 LAO-1 TABLETOP TABLETOP TABLETOP TABLETOP LAO-1 LAO-1 LAO-1 TABLETOP LAO-1 TABLETOP LAO-1 LAO-1 LAO-1 LAO-1 LAO-1 TABLETOP LAO-1 TABLETOP LAO-1 SOV CA-HV1001 DIRT LEG ROOF LEVEL 1 EQUIPMENT 1/2"CA 1/2"CA 1/2"CA EQUIPMENT #6 1/2"CA EQUIPMENT #5 1/2"CA 1/2"CA 1/2"CA 1/2"CA 3/4"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA EQUIPMENT #97 3/4"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA 1/2"CA MA T C H L I N E 2/ P 1 . 4 1/ P 1 . 4 1"CA 1"CA 1"CA 1"CA 1"CA 1"CA LAO-1 LAO-1 TABLETOP LAO-1 TABLETOP LAO-1 LAO-1 LAO-1 LAO-1 TABLETOP LAO-1 TABLETOP LAO-1 TABLETOP LAO-1 TABLETOP LAO-1 TABLETOP LAO-1 TABLETOP LAO-1 LAO-1 TABLETOP LAO-1 TABLETOP LAO-1 TABLETOP LAO-1 TABLETOP TABLETOP REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 P1.4 PLUMBING COMPRESSED AIR RISER DIAGRAM PLUMBING COMPRESSED AIR RISER DIAGRAM SCALE: NONE P1.4 1 PLUMBING COMPRESSED AIR RISER DIAGRAM SCALE: NONE P1.4 2 3009 S Daimler St 11/18/2024 NO SCALE P2.1 1 NO SCALE P2.1 2 NO SCALE 3 NO SCALE 4 NO SCALE 5 NO SCALE 6 NO SCALE 7 P2.1 P2.1 P2.1 P2.1 P2.1 NOTES: 1. ALL CONDENSATE PIPING SHALL BE COPPER TYPE "M". 2. ALL CONDENSATE PIPING SHALL BE INSULATED. 3. SEE PLANS FOR PIPE SIZES, BUT IN NO CASE SHALL BE SMALLER THAN AC UNIT CONNECTION. 4. VERIFY AC UNIT CONNECTION AND LOCATION OF VENT WITH AC UNIT MANUFACTURER. 5. AC UNIT WITH OVERFLOW SENSOR AND ALARM BY OTHERS. "B""A"AC UNIT DRAIN CONNECTION. (TYP) FITTINGS OR "U" BEND TRAP CLEANOUT PLUGSLOPE AT 1/8" PER FOOT LENGTH TOWARD DRAIN SEE PLANS FOR SIZE AND CONTINUATION BLOW THRU TYPE A = SP + 1" MINIMUM B = SP + 1/2" MINIMUM A = (SP x 1.5) + 1" MINIMUM B = (SP x 0.5) MINIMUM DRAW THRU TYPE SP = SYSTEM STATIC PRESSURE IN INCHES VENT CONDENSATE DRAIN DETAIL ROD STIFFENER (TYPICAL) 1 (MIN.) 1 ALL THREADED ROD (TYPICAL) CHANNEL TRANSVERSE BRACES - TYPICAL WHERE REQUIRED BY CODE (9'-4" MAX. LENGTH) BOLT SLEEVE CLEVIS HANGER ADJUSTABLE STEEL YOKE PIPE ROLL 1" (MIN.) 1" ADJUSTABLE HINGE (TYPICAL) ROLLER TYPE PIPE HANGER (FOR PIPING UNDER EXPANSION / CONTRACTION) STANDARD TYPE PIPE HANGER NOTE: 1.REFER TO CPC 2022, TABLE 313.3 FOR STANDARD AND SEISMIC HANGER SPACING INFORMATION AND REQUIREMENTS. 2.REFER TO STRUCTURAL DRAWINGS FOR HANGER ATTACHMENTS TO STRUCTURE (TYP). PIPE HANGER DETAIL ADJUSTABLE HINGE (TYPICAL) ALL THREADED ROD (TYPICAL) CHANNEL LONGITUDINAL BRACES - TYPICAL WHERE REQUIRED BY CODE (9'-4" MAX. LENGTH) ROD STIFFENER (TYPICAL) 1 (MIN.) 1 CHANNEL TRANSVERSE BRACES - TYPICAL WHERE REQUIRED BY CODE (9'-4" MAX. LENGTH) ADJUSTABLE HINGE LONGITUDINAL BRACE HEX NUT & SQUARE WASHERPIPE STRAPSEE NOTE 7 CHANNEL (SIZE AS REQUIRED) ADJUSTABLE HINGE TRANSVERSE BRACE NOTES: 1.ADJUSTABLE HINGES FOR LONGITUDINAL BRACES MAY BE ATTACHED ON EITHER SIDE ADJACENT TO THE ALL-THREADED ROD OR ATTACHED TO THE ALL-THREADED ROD ITSELF. 2.ADJUSTABLE HINGES FOR THE TRANSVERSE BRACES MAY BE ATTACHED TO THE ALL-THREADED ROD. 3.TWO ADJUSTABLE HINGES MAY BE ATTACHED TO THE STRUT TRAPEZE USING THE SAME BOLT OR ALL-THREADED ROD. IT IS NOT NECESSARY TO INSTALL BOTH TRANSVERSE BRACES AND LONGITUDINAL BRACES ON THE SAME TRAPEZE SUPPORT. EITHER SET OF BRACES MAY BE REMOVED TO FORM A LONGITUDINAL BRACE ONLY, OR A TRANSVERSE BRACE ONLY, IF DESIRED. 4.LONGITUDINAL BRACES (WHEN NEEDED) MUST BE INSTALLED AT BOTH ENDS OF TRAPEZE. 5.THE EQUIPMENT SHOWN ON THE TRAPEZE IS GENERIC IN NATURE. ANY NUMBER OF PIPES, CONDUITS, DUCTWORK OR CABLE TRAY MAY BE SUPPORTED FOLLOWING THE SYSTEM WEIGHT AND SUPPORT SPANS LISTED. REFER TO CPC 2022, FOR STANDARD AND SEISMIC HANGER SPACING INFORMATION AND REQUIREMENTS. 6.REFER TO STRUCTURAL DRAWINGS FOR ATTACHMENT OF HANGER SYSTEM TO STRUCTURE. 7.DETERMINE LENGTH OF TRAPEZE, MAKING SURE SUFFICIENT LENGTH IS PROVIDED TO ATTACH THE ALL-THREADED ROD AND BRACING ATTACHMENTS. TRAPEZE PIPE HANGER DETAIL 1/2" COLD WATER FROM NEAREST COLD WATER SUPPLY (SEE PLAN) SHUT-OFF VALVE UNION (TYPICAL) PRIME RITE BY PPP TRAP PRIMER VALVE WITH ACCESS PANEL DISTRIBUTION BOX FOR TWO OR MORE CONNECTIONS FINISHED FLOOR SLOPE TRAP VENTED WASTE TO SYSTEM FLOOR SINK NOTE: SEE PLANS FOR PIPE, FLOOR SINK, AND TRAP PRIMER LOCATIONS. TRAP PRIMER VALVE SHALL BE MOUNTED A MINIMUM OF 12" ABOVE FINISHED FLOOR FOR EVERY 20 FEET OF PRIMER PIPE. TRAP PRIMER DETAIL VENT PIPE THRU ROOF COUNTERFLASHING SLEEVE SEAMLESS LEAD FLASHING WITH STEEL REINFORCED BOOT ("STONEMAN") OR EQUAL) BUILT-UP ROOFING OVER FLANGE, BY ROOFING CONTRACTOR EXISTING ROOF ASSEMBLY. (SEE ARCHITECTURAL PLANS FOR EXACT TYPE OF CONSTRUCTION) HEIGHT AS REQ'D BY CODE HVAC AIR INTAKE 10' MIN NOTES: IF THIS DETAIL DIFFERS FROM THAT SHOWN ON THE ARCHITECTURAL PLANS, THE ARCHITECTURAL DETAIL SHALL BE FOLLOWED. PIPE SUPPORT DETAIL ON ROOF PIPING OUTDOOR RATED GALVANIZED METAL CLAMP LAG BOLT 14 GA. GALVANIZED CHANNEL PREFABRICATED RUBBER SUPPORT BLOCK W/UNISTRUT CHANEL NOTES: 1. FOR PIPE SIZE 2-1/2" AND LESS. 2. PROVIDE SUPPORT AT 10' INTERVALS. ISOLATION ISOLATION SECURE TO ROOF TYPICAL VENT THRU ROOF DETAIL REMARKSNO.DATE ar c h i t e c t u r e in t e r i o r d e s i g n pl a n n i n g 17 8 8 0 S k y P a r k C i r c l e , S u i t e 2 3 0 - I r v i n e , C A 9 2 6 1 4 t e l 9 4 9 . 5 5 3 . 8 9 0 0 Ed w a r d s DA I M L E R A C P L 30 0 9 D A I M L E R S T R E E T . SA N T A A N A , C A 9 2 7 0 5 P2.1 PLUMBING DETAILS REFER TO ARCHITECTURE PLANS FOR ADDITIONAL INFORMATION. NO SCALE 8 P2.1 1" MIN. ABOVE FLOOD RIM CONDENSATE DISCHARGE FINISHED WALL CONDENSATE DRAIN TO FLOOR SINK ALL BRANCH PIPING SHALL CONNECT TO TOP OF MAIN MINIMUM 0.1" PER FOOT SLOPE (TYPICAL) COMPRESSED AIR MAIN (SLOPE DOWN TOWARD BLOW-OFF DRAIN VALVE) TYPICAL AIR BRANCH AIR SUPPLY PIPE DOWN TO BALL VALVE, VERIFY EXACT HEIGHT, SIZE & LOCATION IN FIELD PRIOR TO INSTALLATION COMPRESSED AIR BRANCH DETAIL 3009 S Daimler St 11/18/2024 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 3009 S Daimler St 11/18/2024 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 3009 S Daimler St 11/18/2024 Project For: TDA Architects 17880 Sky Park Circle, Suite 230 Irvine CA 92614 Edwards Advanced Catheter Lab TI Structural Calculations For Santa Ana, CA 3009 Daimler St 92795 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Cover S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 07/23/2024 3009 S Daimler St 11/18/2024 2. New RTUs New RTUs will be installed on the roof. Structural calculations will be provided to verify the adequacy of the (E) roof framing and for seismic anchorage. 3. Replacement RTUs Multiple (E) RTUs are being replaced with equal or lighterweight units on (E) equipmnent pads. Structural calculations will be provided to verify the adequacy of the (E) roof framing and for seismic anchorage. Project Description This project entails additions of all of the following structural items 1. Units on Grade New units will be installed on grade and structural calculations will be provided for the design of seismic anchorage. PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Description S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Use ASCE Hazard Tool PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Hazards S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Hazards S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis Seismic Parameter Determination Risk Cat:II Site Class:D-Default Ss =1.265 MCE R short period spectral response acceleration S1 =0.454 MCE R spectral response acceleration (T=1.0s) SMS =1.519 Site-modified spectral acceleration value SM1 =0.843 Site-modified spectral acceleration value (ASCE 7-16 §11.4-4) SD1 =0.562 Numeric seismic design value at 1.0s SA (ASCE 7-16 §11.4-5) SDC = D Seismic design category (ASCE 7-16 §11.6-1 & §11.6-2) Fv =1.857 Site amplification factor at 1.0s (ASCE 7-16 §11.4-2) Section 11.4.8 Requirements & Exemptions Exception 1 Criteria:Exception Not Allowed Site Class E ?No Ss ≥ 1.0 ?Yes Fa must be taken as equal to that of Site Class C No Exception 2 Criteria:Exception Allowed Site Class D ?Yes S1 ≥ 0.2 ?Yes Ground Motion Hazard Requirments 1. S1 ≥ 0.6 ?No 2. Class E - Ss ≥ 1.0 ?No Exception 3 Criteria:Exception Not Allowed 3. Class D & E - S1 ≥ 0.2 ?Yes Site Class E ?No S1 ≥ 0.2 ?Yes T ≤ Ts ?No Equivalent Static Force Procedure Used For Design ?No Yes Site Response Analysis Per Section 21.1 Required? Ground Motion Hazard Analysis Per Section 21.2 Required? No No Cs determined by Eq. 12.8-2 for values of T ≤ 1.5Ts and taken as 1.5 times the value computed with Eq 12.8-3 or Eq 12.8-4 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Hazards S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis Exception 2 Period Calculations SDS =1.012 g Design spectral response acceleration parameter Ts =0.555 s Short-period transition period TL =8 s Long-period transition period T ≤ 1.5Ts ?Yes Ct =0.02 Approximate period parameter (ASCE7-16 Table 12.8-2)TL ≥ T > 1.5Ts ?No x = 0.75 Approximate period parameter (ASCE7-16 Table 12.8-2) T > TL ?No hn =38 ft Structure height Ta =0.306 s Approximate structure period (ASCE7-16 Eq. 12.8-7) Cs =Value per Eq. 12.8-2 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Dead Load Plywood Sheathing 3 Insulation 2 Mechanical 4 Ceiling 2 Sprinklers 1 Miscellaneous 3 Total 15 psf Live Load Roof Live Load 20 Total 20 psf LOADS PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Load Sheet S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Roof Framing Check - EF Support PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA - S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Roof Framing Check - EF Support EF Demand W EF =75 lbs Weight of new EF L1 =7 in Length of EF base L2 =7.875 in Width of EF base H =18.5 in Height of unit W VFD =30 lbs Weight of new VFD Single EF Pad L1,pad =31 in Length of new roof pad L2,pad =22 in Width of new roof pad qpad =5 psf Weight of roof pad W pad =23.7 lbs Total weight of roof pad W total =128.7 lbs Total design weight of EF, roof pad, and VFD Combined EF Pad L1,pad =92 in Length of new roof pad L2,pad =31 in Width of new roof pad qpad =5 psf Weight of roof pad W pad =99.0 lbs Total weight of roof pad W total =414.0 lbs Total design weight of (3) EFs, combined roof pad, and (3) VFDs Roof Pad 4x12 Check L =8 ft Length of member P =128.7 lbs Worst case demand on member applied at midspan See Attached Enercalc Report PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Roof Framing EFs S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Roof Framing EFs S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis (E) 4x16 Check 1 L =22 ft Span of member tw =8 ft Tributary width of member P =128.7 lbs Demand from units x =18.5 ft Location where demand acts See Attached Enercalc Report (E) 4x16 Check 2 L =22 ft Span of member tw =8 ft Tributary width of member P =128.7 lbs Demand from units x =14.75 ft Location where demand acts See Attached Enercalc Report (E) 4x16 Check 3 L =22 ft Span of member tw =8 ft Tributary width of member P =414.0 lbs Demand from units x =15.917 ft Location where demand acts See Attached Enercalc Report (E) 4x16 Reinforcing Note: All purlins supporting new units will be reinforced per the following calculations. b(E) =3.5 in Width of existing beam d(E) =15.25 in Depth of existing beam IE) =1034.4 in 4 Moment of inertia of (E) member E(E) =1700 ksi Modulus of elasticity of (E) member IE(E) =2E+06 Product of moment of inertia and modulus of elasticty b(R) =1.75 in Width of reinforcing member d(R) =11.88 in Depth of reinforcing member IR) =244.21 in 4 Moment of inertia of reinforcing member E(R) =1900 ksi Modulus of elasticity of reinforcing member IE(R) =463993 Product of moment of inertia and modulus of elasticty BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Roof Framing EFs S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis IEtotal =3E+06 in 4 Sum of products (1 (E) member and (2) reinforcing members) I(E)/Itotal =0.6546 Ratio of (E) member moment of interia/modulus of elastic product to sum I(R)/Itotal =0.1727 Ratio of reinforcing member moment of interia/modulus of elastic product to sum (E) Member Check P(E) =271.0 lbs Demand from worst case units acting on (E) member (P*ratio) x =15.9 ft Location where demand acts DL(E) =9.8 psf Dead load demand on (E) member (DL*ratio) LL(E) =13.1 psf Live load demand on (E) member (LL*ratio) See Attached Enercalc Report Reinforcing Member Check Preinf =71.5 lbs Demand from worst case units acting on single reinforcing member (P*ratio) x =15.9 ft Location where demand acts DLreinf =2.6 psf Dead load demand on single reinforcing member (DL*ratio) LLreinf =3.5 psf Live load demand on single reinforcing member (LL*ratio) See Attached Enercalc Report BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:Roof Pad 4x12 Check Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.1 1000 1000 1500 625 1700 620 180 675 31.21 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Point Load : D = 0.1287 k @ 4.0 ft, (EF + Platform) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.053: 1 Load Combination D Only Span # where maximum occurs Span # 1 Location of maximum on span 4.000ft 3.45 psi= = 990.00psi 4x12Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination D Only = = = 162.00 psi== Section used for this span 4x12 Maximum Shear Stress Ratio 0.021 : 1 7.066 ft= = 52.93psi Maximum Deflection 0 <360 21337 Ratio =0 <180 Max Downward Transient Deflection 0 in 0Ratio = <360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.004 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v n/a n/a Span: 1 : D Only n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 8.0 ft 1 0.053 0.021 0.90 1.100 1.001.00 1.00 0.33 52.9 990.0 0.09 162.01.00 3.41.00 1.00+0.60D 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.018 0.007 1.60 1.100 1.001.00 1.00 0.20 31.8 1,760.0 0.05 288.01.00 2.11.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections D Only 1 0.0045 4.029 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.098 0.098 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:Roof Pad 4x12 Check Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from Load Combinations 0.059 0.059 Max Upward from Load Cases 0.098 0.098 D Only 0.098 0.098 +0.60D 0.059 0.059 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Check 1 Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 8.0 ft, (DL + LL) Point Load : D = 0.1287 k @ 18.50 ft, (EF + Platform) .DESIGN SUMMARY Design N.G. Maximum Bending Stress Ratio 1.264: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 11.080ft 83.31 psi= = 1,250.00psi 4x16Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x16 Maximum Shear Stress Ratio 0.370 : 1 20.796 ft= = 1,580.33psi Maximum Deflection 0 <360 295 Ratio =0 <180 Max Downward Transient Deflection 0.482 in 547Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.892 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 22.0 ft 1 0.805 0.242 0.90 1.000 1.001.00 1.00 8.19 724.2 900.0 1.40 162.01.00 39.31.00 1.00+D+Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 1.264 0.370 1.25 1.000 1.001.00 1.00 17.87 1,580.3 1,250.0 2.96 225.01.00 83.31.00 1.00+D+0.750Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 1.093 0.321 1.25 1.000 1.001.00 1.00 15.45 1,366.3 1,250.0 2.57 225.01.00 72.31.00 1.00+0.60D 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.272 0.082 1.60 1.000 1.001.00 1.00 4.91 434.5 1,600.0 0.84 288.01.00 23.61.00 . 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Check 1 Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.8920 11.080 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 3.228 3.315 Max Upward from Load Combinations 3.228 3.315 Max Upward from Load Cases 1.760 1.760 D Only 1.468 1.555 +D+Lr 3.228 3.315 +D+0.750Lr 2.788 2.875 +0.60D 0.881 0.933 Lr Only 1.760 1.760 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Check 2 Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 8.0 ft, (DL + LL) Point Load : D = 0.1287 k @ 14.750 ft, (EF + Platform) .DESIGN SUMMARY Design N.G. Maximum Bending Stress Ratio 1.282: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 11.161ft 82.69 psi= = 1,250.00psi 4x16Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x16 Maximum Shear Stress Ratio 0.368 : 1 20.796 ft= = 1,601.88psi Maximum Deflection 0 <360 292 Ratio =0 <180 Max Downward Transient Deflection 0.482 in 547Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.903 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 22.0 ft 1 0.829 0.239 0.90 1.000 1.001.00 1.00 8.43 746.0 900.0 1.38 162.01.00 38.61.00 1.00+D+Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 1.282 0.368 1.25 1.000 1.001.00 1.00 18.11 1,601.9 1,250.0 2.94 225.01.00 82.71.00 1.00+D+0.750Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 1.110 0.319 1.25 1.000 1.001.00 1.00 15.69 1,387.9 1,250.0 2.55 225.01.00 71.71.00 1.00+0.60D 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.280 0.081 1.60 1.000 1.001.00 1.00 5.06 447.6 1,600.0 0.83 288.01.00 23.21.00 . 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Check 2 Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.9029 11.080 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 3.250 3.294 Max Upward from Load Combinations 3.250 3.294 Max Upward from Load Cases 1.760 1.760 D Only 1.490 1.534 +D+Lr 3.250 3.294 +D+0.750Lr 2.810 2.854 +0.60D 0.894 0.920 Lr Only 1.760 1.760 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Check 3 Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 8.0 ft, (DL + LL) Point Load : D = 0.4140 k @ 15.917 ft, (EF + Platform) .DESIGN SUMMARY Design N.G. Maximum Bending Stress Ratio 1.339: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 11.401ft 88.68 psi= = 1,250.00psi 4x16Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x16 Maximum Shear Stress Ratio 0.394 : 1 20.796 ft= = 1,673.71psi Maximum Deflection 0 <360 278 Ratio =0 <180 Max Downward Transient Deflection 0.482 in 547Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.947 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 22.0 ft 1 0.911 0.276 0.90 1.000 1.001.00 1.00 9.27 819.9 900.0 1.59 162.01.00 44.61.00 1.00+D+Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 1.339 0.394 1.25 1.000 1.001.00 1.00 18.92 1,673.7 1,250.0 3.16 225.01.00 88.71.00 1.00+D+0.750Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 1.168 0.345 1.25 1.000 1.001.00 1.00 16.51 1,460.0 1,250.0 2.76 225.01.00 77.71.00 1.00+0.60D 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.307 0.093 1.60 1.000 1.001.00 1.00 5.56 491.9 1,600.0 0.95 288.01.00 26.81.00 . 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Check 3 Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.9466 11.161 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 3.322 3.507 Max Upward from Load Combinations 3.322 3.507 Max Upward from Load Cases 1.760 1.760 D Only 1.562 1.747 +D+Lr 3.322 3.507 +D+0.750Lr 2.882 3.067 +0.60D 0.937 1.048 Lr Only 1.760 1.760 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Reinforced Check (Worst Case) Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.00980, Lr = 0.01310 ksf, Tributary Width = 8.0 ft, (DL + LL) Point Load : D = 0.2710 k @ 15.917 ft, (EF + Platform) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.893: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 11.401ft 59.13 psi= = 1,250.00psi 4x16Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x16 Maximum Shear Stress Ratio 0.263 : 1 20.796 ft= = 1,116.50psi Maximum Deflection 0 <360 418 Ratio =0 <180 Max Downward Transient Deflection 0.316 in 835Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.631 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 22.0 ft 1 0.619 0.187 0.90 1.000 1.001.00 1.00 6.30 557.1 900.0 1.08 162.01.00 30.31.00 1.00+D+Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.893 0.263 1.25 1.000 1.001.00 1.00 12.62 1,116.5 1,250.0 2.10 225.01.00 59.11.00 1.00+D+0.750Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.781 0.231 1.25 1.000 1.001.00 1.00 11.04 976.5 1,250.0 1.85 225.01.00 51.91.00 1.00+0.60D 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.209 0.063 1.60 1.000 1.001.00 1.00 3.78 334.3 1,600.0 0.65 288.01.00 18.21.00 . 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Reinforced Check (Worst Case) Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.6315 11.161 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 2.217 2.339 Max Upward from Load Combinations 2.217 2.339 Max Upward from Load Cases 1.153 1.186 D Only 1.065 1.186 +D+Lr 2.217 2.339 +D+0.750Lr 1.929 2.050 +0.60D 0.639 0.711 Lr Only 1.153 1.153 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Reinforcing Member Check (Worst Case) Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist MicroLam LVL 1.9 E 2,600.0 2,600.0 2,510.0 750.0 1,900.0 965.71 285.0 1,555.0 42.010 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.00260, Lr = 0.00350 ksf, Tributary Width = 8.0 ft, (DL + LL) Point Load : D = 0.07150 k @ 15.917 ft, (Unit) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.317: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 11.321ft 43.48 psi= = 3,254.63psi 1.75x11.87Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 356.25 psi== Section used for this span 1.75x11.87 Maximum Shear Stress Ratio 0.122 : 1 21.036 ft= = 1,032.89psi Maximum Deflection 0 <360 393 Ratio =0 <180 Max Downward Transient Deflection 0.320 in 825Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.671 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 22.0 ft 1 0.230 0.090 0.90 1.001 1.001.00 1.00 1.85 539.7 2,343.3 0.32 256.51.00 23.21.00 1.00+D+Lr 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.317 0.122 1.25 1.001 1.001.00 1.00 3.54 1,032.9 3,254.6 0.60 356.31.00 43.51.00 1.00+D+0.750Lr 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.279 0.108 1.25 1.001 1.001.00 1.00 3.12 909.5 3,254.6 0.53 356.31.00 38.41.00 1.00+0.60D 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.078 0.031 1.60 1.001 1.001.00 1.00 1.11 323.8 4,165.9 0.19 456.01.00 13.91.00 . 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Reinforcing Member Check (Worst Case) Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.6711 11.080 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.623 0.655 Max Upward from Load Combinations 0.623 0.655 Max Upward from Load Cases 0.315 0.347 D Only 0.315 0.347 +D+Lr 0.623 0.655 +D+0.750Lr 0.546 0.578 +0.60D 0.189 0.208 Lr Only 0.308 0.308 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA - S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis Roof Framing Check - RTU Support BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Roof Framing Check - RTU Support 7.5 Ton RTU W =805 lbs Weight of new RTU L1 =7.34 ft Length of RTU base L2 =4.96 ft Width of RTU base H =4.11 ft Height of unit W curb =100 lbs Weight of curb DLplatform =5 psf Dead load fo roof platform W total =1087.1 lbs Design weight of unit 5 Ton RTU W =596 lbs Weight of new RTU L1 =6.20 ft Length of RTU base L2 =3.89 ft Width of RTU base H =3.45 ft Height of unit W curb =100 lbs Weight of curb DLplatform =5 psf Dead load fo roof platform W total =816.41 lbs Design weight of unit 3 Ton RTU W =475 lbs Weight of new RTU L1 =6.20 ft Length of RTU base L2 =3.89 ft Width of RTU base H =2.78 ft Height of unit W curb =100 lbs Weight of curb DLplatform =5 psf Dead load fo roof platform W total =695.41 lbs Design weight of unit 2 Ton RTU W =338 lbs Weight of new RTU L1 =4.02 ft Length of RTU base L2 =2.72 ft Width of RTU base H =4.31 ft Height of unit W curb =100 lbs Weight of curb DLplatform =5 psf Dead load fo roof platform W total =492.59 lbs Design weight of unit PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Roof Framing RTUs S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Roof Framing RTUs S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis 7.5 Ton & 5 Ton Unit Support - Worst Case L =22 ft Span of member tw =8 ft Tributary width of member w7.5T =219.24 plf Distributed demand from 7.5 Ton tunit x1 =19.5 ft Location on span where demand starts x2 =22 ft Location on span where demand ends w5T =210.12 plf Distributed demand from 5 Ton tunit x1 =0 ft Location on span where demand starts x2 =3.08 ft Location on span where demand ends b(E) =3.5 in Width of existing beam d(E) =15.25 in Depth of existing beam IE) =1034.4 in 4 Moment of inertia of (E) member E(E) =1700 ksi Modulus of elasticity of (E) member IE(E) =2E+06 Product of moment of inertia and modulus of elasticty b(R) =2.5 in Width of (E) reinforcing member d(R) =13.25 in Depth of (E) reinforcing member IR) =484.63 in 4 Moment of inertia of (E) reinforcing member E(R) =1700 ksi Modulus of elasticity of (E) reinforcing member IE(R) =823864 Product of moment of inertia and modulus of elasticty Note: Framing supporting the 7.5 Ton and 5 Ton units is under worst case loading. Framing under 3 Ton and 2 Ton units is the same type of loading, however units are lighter, therefore following calculations apply to all new RTUs. BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Roof Framing RTUs S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis IEtotal =3E+06 in 4 Sum of products (1 (E) member and 2 (E) reinforcing members) I(E)/Itotal =0.5163 Ratio of (E) member moment of interia/modulus of elastic product to sum I(R)/Itotal =0.2419 Ratio of (E) reinforcing member moment of interia/modulus of elastic product to sum (E) Member Check w7.5T =113.2 plf Demand from worst case units acting on (E) member x1 =19.5 ft Location on span where demand starts x2 =22 ft Location on span where demand ends w5T =108.5 plf Demand from worst case units acting on (E) member x1 =0 ft Location on span where demand starts x2 =3.08 ft Location on span where demand ends DL(E) =7.7 psf Dead load demand on (E) member (DL*ratio) LL(E) =10.3 psf Live load demand on (E) member (LL*ratio) See Attached Enercalc Report (E) Reinforcing Member Check w7.5T =53.0 lbs Demand from worst case units acting on (E) member x1 =19.5 ft Location on span where demand starts x2 =22 ft Location on span where demand ends w5T =50.8 plf Demand from worst case units acting on (E) member x1 =0 ft Location on span where demand starts x2 =3.08 ft Location on span where demand ends DLreinf =3.6 psf Dead load demand on single reinforcing member (DL*ratio) LLreinf =4.8 psf Live load demand on single reinforcing member (LL*ratio) See Attached Enercalc Report BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:7.5T & 5T Support Main Member Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.00770, Lr = 0.01030 ksf, Tributary Width = 8.0 ft, (DL + LL) Uniform Load : D = 0.1085 k/ft, Extent = 0.0 -->> 3.080 ft, Tributary Width = 1.0 ft, (5T) Uniform Load : D = 0.1132 k/ft, Extent = 19.50 -->> 22.0 ft, Tributary Width = 1.0 ft, (7.5T) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.697: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 10.920ft 48.34 psi= = 1,250.00psi 4x16Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x16 Maximum Shear Stress Ratio 0.215 : 1 0.000 ft= = 870.95psi Maximum Deflection 0 <360 533 Ratio =0 <180 Max Downward Transient Deflection 0.248 in 1062Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.495 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 22.0 ft 1 0.478 0.158 0.90 1.000 1.001.00 1.00 4.86 430.0 900.0 0.91 162.01.00 25.71.00 1.00+D+Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.697 0.215 1.25 1.000 1.001.00 1.00 9.85 870.9 1,250.0 1.72 225.01.00 48.31.00 1.00+D+0.750Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.609 0.190 1.25 1.000 1.001.00 1.00 8.60 760.7 1,250.0 1.52 225.01.00 42.71.00 1.00+0.60D 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.161 0.053 1.60 1.000 1.001.00 1.00 2.92 258.0 1,600.0 0.55 288.01.00 15.41.00 . 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:7.5T & 5T Support Main Member Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.4947 11.000 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 2.038 2.002 Max Upward from Load Combinations 2.038 2.002 Max Upward from Load Cases 1.132 1.095 D Only 1.132 1.095 +D+Lr 2.038 2.002 +D+0.750Lr 1.812 1.775 +0.60D 0.679 0.657 Lr Only 0.906 0.906 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:7.5T & 5T Support Reinforcing Member Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.00360, Lr = 0.00480 ksf, Tributary Width = 8.0 ft, (DL + LL) Uniform Load : D = 0.05080 k/ft, Extent = 0.0 -->> 3.080 ft, Tributary Width = 1.0 ft, (5T) Uniform Load : D = 0.0530 k/ft, Extent = 19.50 -->> 22.0 ft, Tributary Width = 1.0 ft, (7.5T) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.686: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 10.920ft 38.06 psi= = 1,125.00psi 3x14Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 3x14 Maximum Shear Stress Ratio 0.169 : 1 0.000 ft= = 771.55psi Maximum Deflection 0 <360 523 Ratio =0 <180 Max Downward Transient Deflection 0.247 in 1068Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.504 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 22.0 ft 1 0.482 0.128 0.90 0.900 1.001.00 1.00 2.38 390.5 810.0 0.46 162.01.00 20.81.00 1.00+D+Lr 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.686 0.169 1.25 0.900 1.001.00 1.00 4.70 771.5 1,125.0 0.84 225.01.00 38.11.00 1.00+D+0.750Lr 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.601 0.150 1.25 0.900 1.001.00 1.00 4.12 676.3 1,125.0 0.74 225.01.00 33.71.00 1.00+0.60D 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.163 0.043 1.60 0.900 1.001.00 1.00 1.43 234.3 1,440.0 0.27 288.01.00 12.51.00 . 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:7.5T & 5T Support Reinforcing Member Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.5043 11.000 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.971 0.954 Max Upward from Load Combinations 0.971 0.954 Max Upward from Load Cases 0.549 0.532 D Only 0.549 0.532 +D+Lr 0.971 0.954 +D+0.750Lr 0.866 0.848 +0.60D 0.329 0.319 Lr Only 0.422 0.422 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA - S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis Anchorage - RTUs/EFs BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Non-Structural Seismic Coefficient Per ASCE 7-16 Design Criteria h =1.00 ft Average Roof Height From Ground z =1.00 ft Component Attachment Height ap =2.50 Component Amplification Factor ASCE 7-16 Table 13.5-1 or 13.6-1 Rp =6.00 ASCE 7-16 Table 13.5-1 or 13.6-1 Ω0 =2.00 Overstrength Factor ASCE 7-16 Table 13.5-1 or 13.6-1 SDS =1.012 Short Period Spectral Acceleration ASCE 7-16 §11.4 Ip =1.00 Component Importance Factor ASCE 7-16 §13.1.3 Analysis F ph =Max(0.3, Min(0.51, 1.62))= 0.506 W p (LRFD) F pv = .2S DS W p = 0.202 W p (LRFD) Component Response Modification Factor 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.32 0.34 0.35 0.37 0.39 0.40 0.42 0.44 0.46 0.47 0.49 0.51 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.64 0.67 0.71 0.74 0.78 0.81 0.84 0.88 0.91 0.94 0.98 1.01 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.10 0.30 0.50 0.70 0.90 1.10 z/ h Seismic Force Seismic Factor Component/Connection Factor Connection to Concrete Factor F Max S I W Min a S I W R z h S I Wp DS p p p DS P P P DS P P= +        03 04 1 2 16. , . , . PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI Load Sheet ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Design Wind Load per ASCE 7-16 Building Data Subscripts 1 and 2 refer to direction of wind load Risk Category:II ASCE 7-16 Table 1.5-1 Exposure Category:C ASCE 7-16 §26.7 hr =38 ft Building average roof height B1 =200 ft Building width B2 =200 ft Building width V =95 mph Basic wind speed ASCE 7-16 Fig. 26.5-1A, B, C, or D Rooftop Structure or Equipment Data h =18.5 in L1 =7 in Af1 =0.9 sf z = 39.542 ft L2 =7.875 in Af2 =1.0 sf zg =46 ft Elevation above sea level Ar =0.4 sf Design Wind Load qz = 0.00256 Kz Kzt Kd Ke V2 =21.6 psf ASCE 7-16 Eq. 26.10-1 Kz =1.0411 Velocity pressure exposure coefficient ASCE 7-16 Table 26.10-1 Kzt =1.0 Topographic factor ASCE 7-16 §26.8 Kd =0.9 Wind directionality factor ASCE 7-16 Table 26.6-1 Ke =1.00 Ground elevation factor ASCE 7-16 Table 26.9-1 Fh = qz (G Cr) Af Lateral force ASCE 7-16 Eq. 29.4-2 Fv = qz (G Cr) Ar Vertical force ASCE 7-16 Eq. 29.4-3 Wind Load (G Cr) Fh1 =22 lb x 1.9 = 42 lb Fh2 =19 lb x 1.9 = 37 lb Fv =8 lb x 1.5 = 12 lb PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab Load Sheet ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Equipment Anchorage Per ASCE 7-16 (ASD) Unit Geometry Unit Dimensions Unit Connections h =18.5 in Nc =4.0 # of conn. L1 =7.0 in Nsc =4.0 # of effective shear conn. L2 =7.9 in Ntc =2.0 # of effective tension conn. Dimensions to Center of Gravity x1 =3.9 in COG or Include 5% ecc. x2 =4.3 in COG or Include 5% ecc. y =12.3 in COG or 2/3*h Loads W p =75 lb Weight of equipment Fph =0.506 *Wp Horizontal seismic force coefficient Ref. ASCE 7-16 §13.3.1 Fpv =0.202 *Wp Vertical seismic force coefficient Ref. ASCE 7-16 §13.3.1 Fph =38 lb Horizontal seismic force Ref. ASCE 7-16 §13.3.1 Fpv =15 lb Vertical seismic force Ref. ASCE 7-16 §13.3.1 Fwh =42 lb Horizontal wind force Ref. ASCE 7-16 Eq. 29.4-2 Fwv =12 lb Vertical wind force Ref. ASCE 7-16 Eq. 29.4-3 Shear Demand (ASD) Vc =7 lb/conn = MAX(0.7*Fph/Nsc, 0.6*Fwh/Nsc) Tension Demand (ASD) Twh =27 lb/conn = Fwh*(h/2)/MIN(L1, L2)/Ntc Twv =3 lb/conn = Fwv/Nc Tw =31 lb/conn = Twv + Twh Tpv =5 lb/conn = Fpv*(MAX(x1, L1 - x1)/L1)*(MAX(x2, L2 - x2)/L2) Tph1 =33 lb/conn = (Fph*y/L1)/Ntc Tph2 =30 lb/conn = (Fph*y/L2)/Ntc TE =38 lb/conn = Tpv + MAX(Tph1, Tph2) CD =15 lb/conn = W p*(MIN(x1, L1 - x1)/L1)*(MIN(x2, L2 - x2)/L2) Tc =17 lb/conn = MAX(0, 0.7*TE - 0.6*CD, 0.6*Tw - 0.6*CD) PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI RTU Unit Anchorage ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI RTU Unit Anchorage ENGINEER DATE SHEET NO. CL S24-0082 Wood Lag Screw Design Design Criteria R α Load: 19 lb @ 69.2 °Vector Load from V b and T b Main Member Species:Douglas Fir-Larch Main Member Thickness:9-1/4 in Side Member Thickness:1/4 in G = 0.50 Specific gravity D = 0.5 in Diameter of lag screw L = 3 in Length of lag screw pz =2.44 in Shear penetration pw =1.69 in Withdrawal penetration From Table Z multiplier (Note 3) Z =320 x 0.6094 Ref. NDS-2018 Table 12J - 11K Allowable Lateral Load Capacity Ref. NDS-2018 Table 11.3.1 Z CD CM Ct Cg C∆Ceg Cdi Ctn Z' =195 1.6 1 1 1 1 1 1 1 =312 lb Allowable Withdrawal Load Capacity Ref. NDS-2018 Table 11.3.1 W CD CM Ct Ceg Ctn W' =378 1.6 1 1 1 1 = 605 lb/in W' x pw = 1022 lb Allowable Vector Load Capacity Demand / Capacity Ref. NDS-2018 §12.4.1 Z'α = 794 lb OK Ref. NDS-2018 Eq.12.4-1 Use 1/2'' diameter 3'' long lag screw Douglas Fir-Larch 0.5 3 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Non-Structural Seismic Coefficient Per ASCE 7-16 Design Criteria h =1.00 ft Average Roof Height From Ground z =1.00 ft Component Attachment Height ap =2.50 Component Amplification Factor ASCE 7-16 Table 13.5-1 or 13.6-1 Rp =6.00 ASCE 7-16 Table 13.5-1 or 13.6-1 Ω0 =2.00 Overstrength Factor ASCE 7-16 Table 13.5-1 or 13.6-1 SDS =1.012 Short Period Spectral Acceleration ASCE 7-16 §11.4 Ip =1.00 Component Importance Factor ASCE 7-16 §13.1.3 Analysis F ph =Max(0.3, Min(0.51, 1.62))= 0.506 W p (LRFD) F pv = .2S DS W p = 0.202 W p (LRFD) Component Response Modification Factor 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.32 0.34 0.35 0.37 0.39 0.40 0.42 0.44 0.46 0.47 0.49 0.51 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.64 0.67 0.71 0.74 0.78 0.81 0.84 0.88 0.91 0.94 0.98 1.01 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.10 0.30 0.50 0.70 0.90 1.10 z/ h Seismic Force Seismic Factor Component/Connection Factor Connection to Concrete Factor F Max S I W Min a S I W R z h S I Wp DS p p p DS P P P DS P P= +        03 04 1 2 16. , . , . PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI Load Sheet ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Design Wind Load per ASCE 7-16 Building Data Subscripts 1 and 2 refer to direction of wind load Risk Category:II ASCE 7-16 Table 1.5-1 Exposure Category:C ASCE 7-16 §26.7 hr =38 ft Building average roof height B1 =200 ft Building width B2 =200 ft Building width V =95 mph Basic wind speed ASCE 7-16 Fig. 26.5-1A, B, C, or D Rooftop Structure or Equipment Data h =51.7 in L1 =48.2 in Af1 =17.3 sf z = 42.31 ft L2 =32.6 in Af2 =11.7 sf zg =46 ft Elevation above sea level Ar =10.9 sf Design Wind Load qz = 0.00256 Kz Kzt Kd Ke V2 =21.9 psf ASCE 7-16 Eq. 26.10-1 Kz =1.056 Velocity pressure exposure coefficient ASCE 7-16 Table 26.10-1 Kzt =1.0 Topographic factor ASCE 7-16 §26.8 Kd =0.9 Wind directionality factor ASCE 7-16 Table 26.6-1 Ke =1.00 Ground elevation factor ASCE 7-16 Table 26.9-1 Fh = qz (G Cr) Af Lateral force ASCE 7-16 Eq. 29.4-2 Fv = qz (G Cr) Ar Vertical force ASCE 7-16 Eq. 29.4-3 Wind Load (G Cr) Fh1 =257 lb x 1.9 = 488 lb Fh2 =380 lb x 1.9 = 722 lb Fv =240 lb x 1.5 = 360 lb PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab Load Sheet ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Equipment Anchorage Per ASCE 7-16 (ASD) Unit Geometry Unit Dimensions Unit Connections h =51.7 in Nc =4.0 # of conn. L1 =48.2 in Nsc =4.0 # of effective shear conn. L2 =32.6 in Ntc =2.0 # of effective tension conn. Dimensions to Center of Gravity x1 =26.5 in COG or Include 5% ecc. x2 =18.0 in COG or Include 5% ecc. y =34.5 in COG or 2/3*h Loads W p =438 lb Weight of equipment Fph =0.506 *Wp Horizontal seismic force coefficient Ref. ASCE 7-16 §13.3.1 Fpv =0.202 *Wp Vertical seismic force coefficient Ref. ASCE 7-16 §13.3.1 Fph =222 lb Horizontal seismic force Ref. ASCE 7-16 §13.3.1 Fpv =88 lb Vertical seismic force Ref. ASCE 7-16 §13.3.1 Fwh =722 lb Horizontal wind force Ref. ASCE 7-16 Eq. 29.4-2 Fwv =360 lb Vertical wind force Ref. ASCE 7-16 Eq. 29.4-3 Shear Demand (ASD) Vc =108 lb/conn = MAX(0.7*Fph/Nsc, 0.6*Fwh/Nsc) Tension Demand (ASD) Twh =286 lb/conn = Fwh*(h/2)/MIN(L1, L2)/Ntc Twv =90 lb/conn = Fwv/Nc Tw =376 lb/conn = Twv + Twh Tpv =27 lb/conn = Fpv*(MAX(x1, L1 - x1)/L1)*(MAX(x2, L2 - x2)/L2) Tph1 =79 lb/conn = (Fph*y/L1)/Ntc Tph2 =117 lb/conn = (Fph*y/L2)/Ntc TE =144 lb/conn = Tpv + MAX(Tph1, Tph2) CD =89 lb/conn = W p*(MIN(x1, L1 - x1)/L1)*(MIN(x2, L2 - x2)/L2) Tc =172 lb/conn = MAX(0, 0.7*TE - 0.6*CD, 0.6*Tw - 0.6*CD) PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI RTU Unit Anchorage ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI RTU Unit Anchorage ENGINEER DATE SHEET NO. CL S24-0082 Wood Lag Screw Design Design Criteria R α Load: 203 lb @ 57.9 °Vector Load from V b and T b Main Member Species:Douglas Fir-Larch Main Member Thickness:9-1/4 in Side Member Thickness:1/4 in G = 0.50 Specific gravity D = 0.5 in Diameter of lag screw L = 3 in Length of lag screw pz =2.44 in Shear penetration pw =1.69 in Withdrawal penetration From Table Z multiplier (Note 3) Z =320 x 0.6094 Ref. NDS-2018 Table 12J - 11K Allowable Lateral Load Capacity Ref. NDS-2018 Table 11.3.1 Z CD CM Ct Cg C∆Ceg Cdi Ctn Z' =195 1.6 1 1 1 1 1 1 1 =312 lb Allowable Withdrawal Load Capacity Ref. NDS-2018 Table 11.3.1 W CD CM Ct Ceg Ctn W' =378 1.6 1 1 1 1 = 605 lb/in W' x pw = 1022 lb Allowable Vector Load Capacity Demand / Capacity Ref. NDS-2018 §12.4.1 Z'α = 621 lb OK Ref. NDS-2018 Eq.12.4-1 Use 1/2'' diameter 3'' long lag screw Douglas Fir-Larch 0.5 3 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Non-Structural Seismic Coefficient Per ASCE 7-16 Design Criteria h =1.00 ft Average Roof Height From Ground z =1.00 ft Component Attachment Height ap =2.50 Component Amplification Factor ASCE 7-16 Table 13.5-1 or 13.6-1 Rp =6.00 ASCE 7-16 Table 13.5-1 or 13.6-1 Ω0 =2.00 Overstrength Factor ASCE 7-16 Table 13.5-1 or 13.6-1 SDS =1.012 Short Period Spectral Acceleration ASCE 7-16 §11.4 Ip =1.00 Component Importance Factor ASCE 7-16 §13.1.3 Analysis F ph =Max(0.3, Min(0.51, 1.62))= 0.506 W p (LRFD) F pv = .2S DS W p = 0.202 W p (LRFD) Component Response Modification Factor 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.32 0.34 0.35 0.37 0.39 0.40 0.42 0.44 0.46 0.47 0.49 0.51 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.64 0.67 0.71 0.74 0.78 0.81 0.84 0.88 0.91 0.94 0.98 1.01 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.10 0.30 0.50 0.70 0.90 1.10 z/ h Seismic Force Seismic Factor Component/Connection Factor Connection to Concrete Factor F Max S I W Min a S I W R z h S I Wp DS p p p DS P P P DS P P= +        03 04 1 2 16. , . , . PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI Load Sheet ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Design Wind Load per ASCE 7-16 Building Data Subscripts 1 and 2 refer to direction of wind load Risk Category:II ASCE 7-16 Table 1.5-1 Exposure Category:C ASCE 7-16 §26.7 hr =38 ft Building average roof height B1 =200 ft Building width B2 =200 ft Building width V =95 mph Basic wind speed ASCE 7-16 Fig. 26.5-1A, B, C, or D Rooftop Structure or Equipment Data h =33.4 in L1 =74.4 in Af1 =17.2 sf z = 40.78 ft L2 =46.7 in Af2 =10.8 sf zg =46 ft Elevation above sea level Ar =24.1 sf Design Wind Load qz = 0.00256 Kz Kzt Kd Ke V2 =21.8 psf ASCE 7-16 Eq. 26.10-1 Kz =1.0478 Velocity pressure exposure coefficient ASCE 7-16 Table 26.10-1 Kzt =1.0 Topographic factor ASCE 7-16 §26.8 Kd =0.9 Wind directionality factor ASCE 7-16 Table 26.6-1 Ke =1.00 Ground elevation factor ASCE 7-16 Table 26.9-1 Fh = qz (G Cr) Af Lateral force ASCE 7-16 Eq. 29.4-2 Fv = qz (G Cr) Ar Vertical force ASCE 7-16 Eq. 29.4-3 Wind Load (G Cr) Fh1 =235 lb x 1.9 = 447 lb Fh2 =375 lb x 1.9 = 712 lb Fv =525 lb x 1.5 = 787 lb PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab Load Sheet ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Equipment Anchorage Per ASCE 7-16 (ASD) Unit Geometry Unit Dimensions Unit Connections h =33.4 in Nc =4.0 # of conn. L1 =74.4 in Nsc =4.0 # of effective shear conn. L2 =46.7 in Ntc =2.0 # of effective tension conn. Dimensions to Center of Gravity x1 =40.9 in COG or Include 5% ecc. x2 =25.7 in COG or Include 5% ecc. y =22.2 in COG or 2/3*h Loads W p =575 lb Weight of equipment Fph =0.506 *Wp Horizontal seismic force coefficient Ref. ASCE 7-16 §13.3.1 Fpv =0.202 *Wp Vertical seismic force coefficient Ref. ASCE 7-16 §13.3.1 Fph =291 lb Horizontal seismic force Ref. ASCE 7-16 §13.3.1 Fpv =116 lb Vertical seismic force Ref. ASCE 7-16 §13.3.1 Fwh =712 lb Horizontal wind force Ref. ASCE 7-16 Eq. 29.4-2 Fwv =787 lb Vertical wind force Ref. ASCE 7-16 Eq. 29.4-3 Shear Demand (ASD) Vc =107 lb/conn = MAX(0.7*Fph/Nsc, 0.6*Fwh/Nsc) Tension Demand (ASD) Twh =127 lb/conn = Fwh*(h/2)/MIN(L1, L2)/Ntc Twv =197 lb/conn = Fwv/Nc Tw =324 lb/conn = Twv + Twh Tpv =35 lb/conn = Fpv*(MAX(x1, L1 - x1)/L1)*(MAX(x2, L2 - x2)/L2) Tph1 =43 lb/conn = (Fph*y/L1)/Ntc Tph2 =69 lb/conn = (Fph*y/L2)/Ntc TE =104 lb/conn = Tpv + MAX(Tph1, Tph2) CD =116 lb/conn = W p*(MIN(x1, L1 - x1)/L1)*(MIN(x2, L2 - x2)/L2) Tc =125 lb/conn = MAX(0, 0.7*TE - 0.6*CD, 0.6*Tw - 0.6*CD) PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI RTU Unit Anchorage ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI RTU Unit Anchorage ENGINEER DATE SHEET NO. CL S24-0082 Wood Lag Screw Design Design Criteria R α Load: 164 lb @ 49.4 °Vector Load from V b and T b Main Member Species:Douglas Fir-Larch Main Member Thickness:9-1/4 in Side Member Thickness:1/4 in G = 0.50 Specific gravity D = 0.5 in Diameter of lag screw L = 3 in Length of lag screw pz =2.44 in Shear penetration pw =1.69 in Withdrawal penetration From Table Z multiplier (Note 3) Z =320 x 0.6094 Ref. NDS-2018 Table 12J - 11K Allowable Lateral Load Capacity Ref. NDS-2018 Table 11.3.1 Z CD CM Ct Cg C∆Ceg Cdi Ctn Z' =195 1.6 1 1 1 1 1 1 1 =312 lb Allowable Withdrawal Load Capacity Ref. NDS-2018 Table 11.3.1 W CD CM Ct Ceg Ctn W' =378 1.6 1 1 1 1 = 605 lb/in W' x pw = 1022 lb Allowable Vector Load Capacity Demand / Capacity Ref. NDS-2018 §12.4.1 Z'α = 520 lb OK Ref. NDS-2018 Eq.12.4-1 Use 1/2'' diameter 3'' long lag screw Douglas Fir-Larch 0.5 3 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Non-Structural Seismic Coefficient Per ASCE 7-16 Design Criteria h =1.00 ft Average Roof Height From Ground z =1.00 ft Component Attachment Height ap =2.50 Component Amplification Factor ASCE 7-16 Table 13.5-1 or 13.6-1 Rp =6.00 ASCE 7-16 Table 13.5-1 or 13.6-1 Ω0 =2.00 Overstrength Factor ASCE 7-16 Table 13.5-1 or 13.6-1 SDS =1.012 Short Period Spectral Acceleration ASCE 7-16 §11.4 Ip =1.00 Component Importance Factor ASCE 7-16 §13.1.3 Analysis F ph =Max(0.3, Min(0.51, 1.62))= 0.506 W p (LRFD) F pv = .2S DS W p = 0.202 W p (LRFD) Component Response Modification Factor 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.32 0.34 0.35 0.37 0.39 0.40 0.42 0.44 0.46 0.47 0.49 0.51 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.64 0.67 0.71 0.74 0.78 0.81 0.84 0.88 0.91 0.94 0.98 1.01 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.10 0.30 0.50 0.70 0.90 1.10 z/ h Seismic Force Seismic Factor Component/Connection Factor Connection to Concrete Factor F Max S I W Min a S I W R z h S I Wp DS p p p DS P P P DS P P= +        03 04 1 2 16. , . , . PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI Load Sheet ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Design Wind Load per ASCE 7-16 Building Data Subscripts 1 and 2 refer to direction of wind load Risk Category:II ASCE 7-16 Table 1.5-1 Exposure Category:C ASCE 7-16 §26.7 hr =38 ft Building average roof height B1 =200 ft Building width B2 =200 ft Building width V =95 mph Basic wind speed ASCE 7-16 Fig. 26.5-1A, B, C, or D Rooftop Structure or Equipment Data h =41.4 in L1 =74.4 in Af1 =21.4 sf z = 41.45 ft L2 =46.7 in Af2 =13.4 sf zg =46 ft Elevation above sea level Ar =24.1 sf Design Wind Load qz = 0.00256 Kz Kzt Kd Ke V2 =21.8 psf ASCE 7-16 Eq. 26.10-1 Kz =1.0514 Velocity pressure exposure coefficient ASCE 7-16 Table 26.10-1 Kzt =1.0 Topographic factor ASCE 7-16 §26.8 Kd =0.9 Wind directionality factor ASCE 7-16 Table 26.6-1 Ke =1.00 Ground elevation factor ASCE 7-16 Table 26.9-1 Fh = qz (G Cr) Af Lateral force ASCE 7-16 Eq. 29.4-2 Fv = qz (G Cr) Ar Vertical force ASCE 7-16 Eq. 29.4-3 Wind Load (G Cr) Fh1 =293 lb x 1.9 = 557 lb Fh2 =467 lb x 1.9 = 887 lb Fv =526 lb x 1.5 = 790 lb PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab Load Sheet ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Equipment Anchorage Per ASCE 7-16 (ASD) Unit Geometry Unit Dimensions Unit Connections h =41.4 in Nc =4.0 # of conn. L1 =74.4 in Nsc =4.0 # of effective shear conn. L2 =46.7 in Ntc =2.0 # of effective tension conn. Dimensions to Center of Gravity x1 =40.9 in COG or Include 5% ecc. x2 =25.7 in COG or Include 5% ecc. y =27.6 in COG or 2/3*h Loads W p =696 lb Weight of equipment Fph =0.506 *Wp Horizontal seismic force coefficient Ref. ASCE 7-16 §13.3.1 Fpv =0.202 *Wp Vertical seismic force coefficient Ref. ASCE 7-16 §13.3.1 Fph =352 lb Horizontal seismic force Ref. ASCE 7-16 §13.3.1 Fpv =141 lb Vertical seismic force Ref. ASCE 7-16 §13.3.1 Fwh =887 lb Horizontal wind force Ref. ASCE 7-16 Eq. 29.4-2 Fwv =790 lb Vertical wind force Ref. ASCE 7-16 Eq. 29.4-3 Shear Demand (ASD) Vc =133 lb/conn = MAX(0.7*Fph/Nsc, 0.6*Fwh/Nsc) Tension Demand (ASD) Twh =197 lb/conn = Fwh*(h/2)/MIN(L1, L2)/Ntc Twv =197 lb/conn = Fwv/Nc Tw =394 lb/conn = Twv + Twh Tpv =43 lb/conn = Fpv*(MAX(x1, L1 - x1)/L1)*(MAX(x2, L2 - x2)/L2) Tph1 =65 lb/conn = (Fph*y/L1)/Ntc Tph2 =104 lb/conn = (Fph*y/L2)/Ntc TE =147 lb/conn = Tpv + MAX(Tph1, Tph2) CD =141 lb/conn = W p*(MIN(x1, L1 - x1)/L1)*(MIN(x2, L2 - x2)/L2) Tc =152 lb/conn = MAX(0, 0.7*TE - 0.6*CD, 0.6*Tw - 0.6*CD) PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI RTU Unit Anchorage ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI RTU Unit Anchorage ENGINEER DATE SHEET NO. CL S24-0082 Wood Lag Screw Design Design Criteria R α Load: 202 lb @ 48.8 °Vector Load from V b and T b Main Member Species:Douglas Fir-Larch Main Member Thickness:9-1/4 in Side Member Thickness:1/4 in G = 0.50 Specific gravity D = 0.5 in Diameter of lag screw L = 3 in Length of lag screw pz =2.44 in Shear penetration pw =1.69 in Withdrawal penetration From Table Z multiplier (Note 3) Z =320 x 0.6094 Ref. NDS-2018 Table 12J - 11K Allowable Lateral Load Capacity Ref. NDS-2018 Table 11.3.1 Z CD CM Ct Cg C∆Ceg Cdi Ctn Z' =195 1.6 1 1 1 1 1 1 1 =312 lb Allowable Withdrawal Load Capacity Ref. NDS-2018 Table 11.3.1 W CD CM Ct Ceg Ctn W' =378 1.6 1 1 1 1 = 605 lb/in W' x pw = 1022 lb Allowable Vector Load Capacity Demand / Capacity Ref. NDS-2018 §12.4.1 Z'α = 514 lb OK Ref. NDS-2018 Eq.12.4-1 Use 1/2'' diameter 3'' long lag screw Douglas Fir-Larch 0.5 3 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Non-Structural Seismic Coefficient Per ASCE 7-16 Design Criteria h =1.00 ft Average Roof Height From Ground z =1.00 ft Component Attachment Height ap =2.50 Component Amplification Factor ASCE 7-16 Table 13.5-1 or 13.6-1 Rp =6.00 ASCE 7-16 Table 13.5-1 or 13.6-1 Ω0 =2.00 Overstrength Factor ASCE 7-16 Table 13.5-1 or 13.6-1 SDS =1.012 Short Period Spectral Acceleration ASCE 7-16 §11.4 Ip =1.00 Component Importance Factor ASCE 7-16 §13.1.3 Analysis F ph =Max(0.3, Min(0.51, 1.62))= 0.506 W p (LRFD) F pv = .2S DS W p = 0.202 W p (LRFD) Component Response Modification Factor 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.32 0.34 0.35 0.37 0.39 0.40 0.42 0.44 0.46 0.47 0.49 0.51 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.64 0.67 0.71 0.74 0.78 0.81 0.84 0.88 0.91 0.94 0.98 1.01 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.10 0.30 0.50 0.70 0.90 1.10 z/ h Seismic Force Seismic Factor Component/Connection Factor Connection to Concrete Factor F Max S I W Min a S I W R z h S I Wp DS p p p DS P P P DS P P= +        03 04 1 2 16. , . , . PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI Load Sheet ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Design Wind Load per ASCE 7-16 Building Data Subscripts 1 and 2 refer to direction of wind load Risk Category:II ASCE 7-16 Table 1.5-1 Exposure Category:C ASCE 7-16 §26.7 hr =38 ft Building average roof height B1 =200 ft Building width B2 =200 ft Building width V =95 mph Basic wind speed ASCE 7-16 Fig. 26.5-1A, B, C, or D Rooftop Structure or Equipment Data h =49.3 in L1 =88.1 in Af1 =30.2 sf z = 42.11 ft L2 =59.5 in Af2 =20.4 sf zg =46 ft Elevation above sea level Ar =36.4 sf Design Wind Load qz = 0.00256 Kz Kzt Kd Ke V2 =21.9 psf ASCE 7-16 Eq. 26.10-1 Kz =1.0549 Velocity pressure exposure coefficient ASCE 7-16 Table 26.10-1 Kzt =1.0 Topographic factor ASCE 7-16 §26.8 Kd =0.9 Wind directionality factor ASCE 7-16 Table 26.6-1 Ke =1.00 Ground elevation factor ASCE 7-16 Table 26.9-1 Fh = qz (G Cr) Af Lateral force ASCE 7-16 Eq. 29.4-2 Fv = qz (G Cr) Ar Vertical force ASCE 7-16 Eq. 29.4-3 Wind Load (G Cr) Fh1 =446 lb x 1.9 = 848 lb Fh2 =661 lb x 1.9 = 1255 lb Fv =797 lb x 1.5 = 1196 lb PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab Load Sheet ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Equipment Anchorage Per ASCE 7-16 (ASD) Unit Geometry Unit Dimensions Unit Connections h =49.3 in Nc =4.0 # of conn. L1 =88.1 in Nsc =4.0 # of effective shear conn. L2 =59.5 in Ntc =2.0 # of effective tension conn. Dimensions to Center of Gravity x1 =48.4 in COG or Include 5% ecc. x2 =32.7 in COG or Include 5% ecc. y =32.9 in COG or 2/3*h Loads W p =905 lb Weight of equipment Fph =0.506 *Wp Horizontal seismic force coefficient Ref. ASCE 7-16 §13.3.1 Fpv =0.202 *Wp Vertical seismic force coefficient Ref. ASCE 7-16 §13.3.1 Fph =458 lb Horizontal seismic force Ref. ASCE 7-16 §13.3.1 Fpv =183 lb Vertical seismic force Ref. ASCE 7-16 §13.3.1 Fwh =1255 lb Horizontal wind force Ref. ASCE 7-16 Eq. 29.4-2 Fwv =1196 lb Vertical wind force Ref. ASCE 7-16 Eq. 29.4-3 Shear Demand (ASD) Vc =188 lb/conn = MAX(0.7*Fph/Nsc, 0.6*Fwh/Nsc) Tension Demand (ASD) Twh =260 lb/conn = Fwh*(h/2)/MIN(L1, L2)/Ntc Twv =299 lb/conn = Fwv/Nc Tw =559 lb/conn = Twv + Twh Tpv =55 lb/conn = Fpv*(MAX(x1, L1 - x1)/L1)*(MAX(x2, L2 - x2)/L2) Tph1 =85 lb/conn = (Fph*y/L1)/Ntc Tph2 =126 lb/conn = (Fph*y/L2)/Ntc TE =182 lb/conn = Tpv + MAX(Tph1, Tph2) CD =183 lb/conn = W p*(MIN(x1, L1 - x1)/L1)*(MIN(x2, L2 - x2)/L2) Tc =225 lb/conn = MAX(0, 0.7*TE - 0.6*CD, 0.6*Tw - 0.6*CD) PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI RTU Unit Anchorage ENGINEER DATE SHEET NO. CL S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI RTU Unit Anchorage ENGINEER DATE SHEET NO. CL S24-0082 Wood Lag Screw Design Design Criteria R α Load: 294 lb @ 50.1 °Vector Load from V b and T b Main Member Species:Douglas Fir-Larch Main Member Thickness:9-1/4 in Side Member Thickness:1/4 in G = 0.50 Specific gravity D = 0.5 in Diameter of lag screw L = 3 in Length of lag screw pz =2.44 in Shear penetration pw =1.69 in Withdrawal penetration From Table Z multiplier (Note 3) Z =320 x 0.6094 Ref. NDS-2018 Table 12J - 11K Allowable Lateral Load Capacity Ref. NDS-2018 Table 11.3.1 Z CD CM Ct Cg C∆Ceg Cdi Ctn Z' =195 1.6 1 1 1 1 1 1 1 =312 lb Allowable Withdrawal Load Capacity Ref. NDS-2018 Table 11.3.1 W CD CM Ct Ceg Ctn W' =378 1.6 1 1 1 1 = 605 lb/in W' x pw = 1022 lb Allowable Vector Load Capacity Demand / Capacity Ref. NDS-2018 §12.4.1 Z'α = 528 lb OK Ref. NDS-2018 Eq.12.4-1 Use 1/2'' diameter 3'' long lag screw Douglas Fir-Larch 0.5 3 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA - S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis Anchorage - Units On Grade BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Units On Grade 3D Laser Link W =800 lbs Max weight of equipment L1 =45 in Length of equipment base L2 =42 in Width of equipment base H =84 in Max height of unit Pyrolosis Furnace W =800 lbs Max weight of equipment L1 =84 in Length of equipment base L2 =36 in Width of equipment base H =84 in Max height of unit Despatch Oven W =800 lbs Max weight of equipment L1 =72 in Length of equipment base L2 =72 in Width of equipment base H =84 in Max height of unit Worst Case Anchorage W =800 lbs Max weight of equipment L1 =45 in Worst case length of equipment base L2 =36 in Worst case width of equipment base H =84 in Worst case height of unit See Attached Anchorage Calculations PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Anchorage S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Non-Structural Seismic Coefficient Per ASCE 7-16 Design Criteria h =1.00 ft Average Roof Height From Ground z =1.00 ft Component Attachment Height ap =1.00 Component Amplification Factor ASCE 7-16 Table 13.5-1 or 13.6-1 Rp =1.50 ASCE 7-16 Table 13.5-1 or 13.6-1 Ω0 =2.00 Overstrength Factor ASCE 7-16 Table 13.5-1 or 13.6-1 SDS =1.012 Short Period Spectral Acceleration ASCE 7-16 §11.4.4 Ip =1.00 Component Importance Factor ASCE 7-16 §13.1.3 Analysis F ph =Max(0.3, Min(0.81, 1.62))= 0.810 W p (LRFD) F pv = .2S DS W p = 0.202 W p (LRFD) Component Response Modification Factor 0.30 0.30 0.32 0.35 0.38 0.40 0.43 0.46 0.49 0.51 0.54 0.57 0.59 0.62 0.65 0.67 0.70 0.73 0.76 0.78 0.81 0.61 0.61 0.65 0.70 0.76 0.81 0.86 0.92 0.97 1.03 1.08 1.13 1.19 1.24 1.30 1.35 1.40 1.46 1.51 1.57 1.62 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.10 0.30 0.50 0.70 0.90 1.10 1.30 1.50 1.70 z/ h Seismic Force Seismic Factor Component/Connection Factor Connection to Concrete Factor F Max S I W Min a S I W R z h S I Wp DS p p p DS P P P DS P P= +        03 04 1 2 16. , . , . PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI Load Sheet ENGINEER DATE SHEET NO. 7/22/2024 C. Landis S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Design Wind Load Per ASCE 7-16 Building Data Subscripts 1 and 2 refer to direction of wind load Risk Category:II ASCE 7-16 Table 1.5-1 Exposure Category:C ASCE 7-16 §26.7 hr =0 ft Building average roof height B1 =N/A ft Building width B2 =N/A ft Building width V =95 mph Basic wind speed ASCE 7-16 Fig. 26.5-1A, B, or C Equipment Data h =84 in L1 =45 in Af1 =26.3 sf z = 7 ft L2 =36 in Af2 =21.0 sf zg =46 ft Elevation above sea level Design Wind Load qz = 0.00256 Kz Kzt Kd Ke V2 =5.0 psf ASCE 7-16 Eq. 29.3-1 Kz =0.8489 Velocity pressure exposure coefficient ASCE 7-16 Table 29.3-1 Kzt =1.0 Topographic factor ASCE 7-16 §26.8 Kd =0.9 Wind directionality factor ASCE 7-16 Table 26.6-1 Ke =1.0 Wind directionality factor ASCE 7-16 Table 26.6-2 G =0.85 Gust effect factor ASCE 7-16 §26.9 Cf =1.32 Force coefficient ASCE 7-16 Fig. 29.5-1 Fh = qz (G Cf) Af Lateral force ASCE 7-16 Eq. 29.5-1 qz Af G Cf Fh1 =105 lb x 1.1239 = 118 lb Fh2 =131 lb x 1.1239 = 148 lb PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI Load Sheet ENGINEER DATE SHEET NO. 7/22/2024 C. Landis S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Equipment Anchorage Per 2019 CBC (LRFD) Unit Geometry Unit Dimensions Unit Connections h =84.0 in Nc =6.0 # of conn. L1 =45.0 in Nsc =6.0 # of effective shear conn. L2 =36.0 in Ntc =3.0 # of effective tension conn. Dimensions to Center of Gravity x1 =24.8 in COG or Include 5% ecc. x2 =19.8 in COG or Include 5% ecc. y =56.3 in COG or 2/3*h Loads W p =800 lb Weight of equipment Fph =0.810 *Wp Horizontal seismic force coefficient Ref. ASCE 7-16 §13.3.1 Fpv =0.202 *Wp Vertical seismic force coefficient Ref. ASCE 7-16 §13.3.1 Fph =648 lb Horizontal seismic force Ref. ASCE 7-16 §13.3.1 Fpv =162 lb Vertical seismic force Ref. ASCE 7-16 §13.3.1 Fwh =148 lb Horizontal wind force Ref. ASCE 7-16 Eq. 29.5-1 Shear Vc =216 lb/conn = MAX(Ω0Fph/Nsc, Fwh/Nsc) Tension TW =57.4 lb/conn = Fwh*(h/2)/MIN(L1, L2)/Ntw Tpv =48.9 lb/conn = Fpv*(MAX(x1, L1 - x1)/L1)*(MAX(x2, L2 - x2)/L2) Tph1 =270.1 lb/conn = (Fph*y/L1)/Nte Tph2 =337.7 lb/conn = (Fph*y/L2)/Nte TE =724.2 lb/conn = Tpv + Ω0*MAX(Tph1 , Tph2) CD =162.0 lb/conn = W p*(MIN(x1, L1 - x1)/L1)*(MIN(x2, L2 - x2)/L2) Tc =578 lb/conn = MAX(0, TE - 0.9*CD, Tw - 0.9*CD) Notes: 1. Anchors in concrete must be designed in accordance with chapter 17 of ACI 318. Ref. ASCE 7-16 §13.4.2.1 PROJECT PROJECT NO. ITEM Edwards Advanced Catheter Lab TI Load Sheet ENGINEER DATE SHEET NO. 7/22/2024 C. Landis S24-0082 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.1 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Jul 22, 2024 Page: Specifier: E-Mail: Date: 1 7/22/2024 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - CS 1/2 (1 1/2) hnom1 Item number: 2210254 KB-TZ2 1/2x3 3/4 Specification text: Hilti KB-TZ2 stud anchor with 2 in embedment, 1/2 (1 1/2) hnom1, Carbon steel, installation per ESR-4266 Effective embedment depth: hef,act = 1.500 in., hnom = 2.000 in. Material: Carbon Steel Evaluation Service Report: ESR-4266 Issued I Valid: 12/1/2023 | 12/1/2025 Proof: Design Method ACI 318-19 / Mech Stand-off installation: Profile: Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 5.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) Shear load: yes (17.10.6.3 (c)) 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.1 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Jul 22, 2024 Page: Specifier: E-Mail: Date: 2 7/22/2024 Geometry [in.] & Loading [lb, in.lb] 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.1 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Jul 22, 2024 Page: Specifier: E-Mail: Date: 3 7/22/2024 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 578; Vx = 0; Vy = 216; Mx = 0; My = 0; Mz = 0; yes 54 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 578 216 0 216 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*578 8,433 7 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**578 1,075 54 OK * highest loaded anchor **anchor group (anchors in tension) 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.1 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Jul 22, 2024 Page: Specifier: E-Mail: Date: 4 7/22/2024 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4266 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.10 114,004 Calculations Nsa [lb] 11,244 Results Nsa [lb]f steel f nonductile f Nsa [lb]Nua [lb] 11,244 0.750 1.000 8,433 578 3.2 Concrete Breakout Failure Ncb = (ANc ANc0)y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1a) f Ncb ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ca,min [in.]y c,N cac [in.]kc l a f' c [psi] 1.500 ∞1.000 8.000 24 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 20.25 20.25 1.000 1.000 2,205 Results Ncb [lb]f concrete f seismic f nonductile f Ncb [lb]Nua [lb] 2,205 0.650 0.750 1.000 1,075 578 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.1 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Jul 22, 2024 Page: Specifier: E-Mail: Date: 5 7/22/2024 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*216 3,599 7 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**216 1,543 14 OK Concrete edge failure in direction **N/A N/A N/A N/A * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa,eq = ESR value refer to ICC-ES ESR-4266 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi]aV,seis 0.10 114,004 1.000 Calculations Vsa,eq [lb] 5,537 Results Vsa,eq [lb]f steel f nonductile f Vsa,eq [lb]Vua [lb] 5,537 0.650 1.000 3,599 216 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.1 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Jul 22, 2024 Page: Specifier: E-Mail: Date: 6 7/22/2024 4.2 Pryout Strength Vcp = kcp [(ANc ANc0)y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1a) f Vcp ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ca,min [in.]y c,N 1 1.500 ∞1.000 cac [in.]kc l a f' c [psi] 8.000 24 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 20.25 20.25 1.000 1.000 2,205 Results Vcp [lb]f concrete f seismic f nonductile f Vcp [lb]Vua [lb] 2,205 0.700 1.000 1.000 1,543 216 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.538 0.140 5/3 40 OK bNV = bz N + bz V <= 1 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.1 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Jul 22, 2024 Page: Specifier: E-Mail: Date: 7 7/22/2024 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • "An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-19, Chapter 17, Section 17.10.5.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.10.5.3 (b), Section 17.10.5.3 (c), or Section 17.10.5.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.10.6.3 (a), Section 17.10.6.3 (b), or Section 17.10.6.3 (c)." • Section 17.10.5.3 (b) / Section 17.10.6.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.10.5.3 (c) / Section 17.10.6.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Section 17.10.5.3 (d) / Section 17.10.6.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by w0. • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.1 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Jul 22, 2024 Page: Specifier: E-Mail: Date: 8 7/22/2024 7 Installation data Anchor type and diameter: Kwik Bolt TZ2 - CS 1/2 (1 1/2) hnom1 Profile: - Item number: 2210254 KB-TZ2 1/2x3 3/4 Hole diameter in the fixture: - Maximum installation torque: 602 in.lb Plate thickness (input): - Hole diameter in the base material: 0.500 in. Hole depth in the base material: 2.250 in. Drilling method: Hammer drilled Minimum thickness of the base material: 3.500 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti KB-TZ2 stud anchor with 2 in embedment, 1/2 (1 1/2) hnom1, Carbon steel, installation per ESR-4266 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool • Torque wrench • Hammer Coordinates Anchor in. Anchor x y c-x c+x c-y c+y 1 0.000 0.000 ---- 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.1 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 9 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Jul 22, 2024 Page: Specifier: E-Mail: Date: 9 7/22/2024 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 3009 S Daimler St 11/18/2024 Project For: TDA Architects 17880 Sky Park Circle, Suite 230 Irvine CA 92614 Supplemental Calculations Edwards Advanced Catheter Lab TI Structural Calculations For Santa Ana, CA 3009 Daimler St 92795 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Cover S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 09/25/2024 3009 S Daimler St 11/18/2024 Project Description This project entails additions of all of the following structural items 1. Units on Grade (See Previously Submitted Calculation Package) New units will be installed on grade and structural calculations will be provided for the design of seismic anchorage. 2. New RTUs (See Previously Submitted Calculation Package) New RTUs will be installed on the roof. Structural calculations will be provided to verify the adequacy of the (E) roof framing and for seismic anchorage. 3. Replacement RTUs (See Previously Submitted Calculation Package) Multiple (E) RTUs are being replaced with equal or lighterweight units on (E) equipmnent pads. Structural calculations will be provided to verify the adequacy of the (E) roof framing and for seismic anchorage. 4. New Wind Screen Structural calculations will be provided for the design of a new roof wind screen and the (E) framing will be analyzed and reinforced where required. PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Description S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Use ASCE Hazard Tool PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Hazards S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Hazards S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis Seismic Parameter Determination Risk Cat:II Site Class:D-Default Ss =1.265 MCE R short period spectral response acceleration S1 =0.454 MCE R spectral response acceleration (T=1.0s) SMS =1.519 Site-modified spectral acceleration value SM1 =0.843 Site-modified spectral acceleration value (ASCE 7-16 §11.4-4) SD1 =0.562 Numeric seismic design value at 1.0s SA (ASCE 7-16 §11.4-5) SDC = D Seismic design category (ASCE 7-16 §11.6-1 & §11.6-2) Fv =1.857 Site amplification factor at 1.0s (ASCE 7-16 §11.4-2) Section 11.4.8 Requirements & Exemptions Exception 1 Criteria:Exception Not Allowed Site Class E ?No Ss ≥ 1.0 ?Yes Fa must be taken as equal to that of Site Class C No Exception 2 Criteria:Exception Allowed Site Class D ?Yes S1 ≥ 0.2 ?Yes Ground Motion Hazard Requirments 1. S1 ≥ 0.6 ?No 2. Class E - Ss ≥ 1.0 ?No Exception 3 Criteria:Exception Not Allowed 3. Class D & E - S1 ≥ 0.2 ?Yes Site Class E ?No S1 ≥ 0.2 ?Yes T ≤ Ts ?No Equivalent Static Force Procedure Used For Design ?No Yes Site Response Analysis Per Section 21.1 Required? Ground Motion Hazard Analysis Per Section 21.2 Required? No No Cs determined by Eq. 12.8-2 for values of T ≤ 1.5Ts and taken as 1.5 times the value computed with Eq 12.8-3 or Eq 12.8-4 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Hazards S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis Exception 2 Period Calculations SDS =1.012 g Design spectral response acceleration parameter Ts =0.555 s Short-period transition period TL =8 s Long-period transition period T ≤ 1.5Ts ?Yes Ct =0.02 Approximate period parameter (ASCE7-16 Table 12.8-2)TL ≥ T > 1.5Ts ?No x = 0.75 Approximate period parameter (ASCE7-16 Table 12.8-2) T > TL ?No hn =38 ft Structure height Ta =0.306 s Approximate structure period (ASCE7-16 Eq. 12.8-7) Cs =Value per Eq. 12.8-2 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Dead Load Plywood Sheathing 3 Insulation 2 Mechanical 4 Ceiling 2 Sprinklers 1 Miscellaneous 3 Total 15 psf Live Load Roof Live Load 20 Total 20 psf LOADS PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Load Sheet S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Roof Screen Framing Check PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA - S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Design Wind Load per ASCE 7-16 Building Data Subscripts 1 and 2 refer to direction of wind load Risk Category:II ASCE 7-16 Table 1.5-1 Exposure Category:C ASCE 7-16 §26.7 hr =20 ft Building average roof height B1 =215 ft Building width B2 =200 ft Building width V =95 mph Basic wind speed ASCE 7-16 Fig. 26.5-1A, B, C, or D Rooftop Wind Screen Data hscreen =6 ft L1 =44.8 ft Af1 =268.5 sf z = 26.0 ft L2 =43.8 ft Af2 =262.5 sf zg =46 ft Elevation above sea level Design Wind Load qh = 0.00256 Kh Kzt Kd Ke V2 =18.7 psf ASCE 7-16 Eq. 26.10-1 Kh =0.90 Velocity pressure exposure coefficient ASCE 7-16 Table 26.10-1 Kzt =1.0 Topographic factor ASCE 7-16 §26.8 Kd =0.9 Wind directionality factor ASCE 7-16 Table 26.6-1 Ke =1.00 Ground elevation factor ASCE 7-16 Table 26.9-1 Fh = qz (G Cr) Af Lateral force ASCE 7-16 Eq. 29.4-2 Wind Load (G Cr) Fh1 =4915 lb x 1.9 = 9338 lb Fh2 =5027 lb x 1.9 = 9551 lb pw = 35.6 psf Design wind pressure ASCE 7-16 Eq. 29.4-2 PROJECT PROJECT NO. ITEM Load Sheet ENGINEER DATE SHEET NO. S24-0082 Edwards Advanced Catheter Lab TI BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Roof Screen Framing Check Demand DL =15 psf Roof dead load LL =20 psf Roof live load H =8.5 ft Total height of wind screen above roof Habv =6 ft Height of windscreen above parapet sbrace =8 ft Spacing of lateral braces DLscreen =8 psf Dead load of roof screen pwind =35.6 psf Wind demand (See calculations) Framing Check: East-West Screen Support (For Members w/ (E) Reinfocement) L =19.5 ft Span of member tw =8 ft Trib width of member PDL =384 lbs Dead load demand from roof screen framing x =14 ft Location on span where demand acts Pwind,lat =1708.8 lbs Lateral wind force on section of screen trib to member Mwind =9398.4 lb-ft Moment demand on member from lateral wind loading x =12 ft Location on span where demand acts b(E) =3.5 in Width of existing beam d(E) =15.25 in Depth of existing beam IE) =1034.4 in 4 Moment of inertia of (E) member E(E) =1700 ksi Modulus of elasticity of (E) member IE(E) =2E+06 Product of moment of inertia and modulus of elasticty b(R) =2.5 in Width of (E) reinforcing member d(R) =13.25 in Depth of (E) reinforcing member IR) =484.63 in 4 Moment of inertia of (E) reinforcing member E(R) =1700 ksi Modulus of elasticity of (E) reinforcing member IE(R) =823864 Product of moment of inertia and modulus of elasticty IEtotal =3E+06 in 4 Sum of products (1 (E) member and 2 (E) reinforcing members) I(E)/Itotal =0.5163 Ratio of (E) member moment of interia/modulus of elastic product to sum I(R)/Itotal =0.2419 Ratio of (E) reinforcing member moment of interia/modulus of elastic product to sum PDL,m =198 lbs Dead load demand from roof screen framing acting on (E) member PDL,r =93 lbs Dead load demand from roof screen framing acting on (E) reinforcing member x =14 ft Location on span where demand acts PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Anchorage S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH CHECK 1: 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Anchorage S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis Mwind,m =4852 lb-ft Moment demand on (E) member from lateral wind loading Mwind,r =2273.2 lb-ft Moment demand on (E) reinforcing member from lateral wind loading x =12 ft Location on span where demand acts DLm =7.7 psf Roof dead load on (E) member DLr =3.6 psf Roof dead load on (E) reinforcing member LLm =10.3 psf Roof live load on (E) member LLr =4.8 psf Roof live load on (E) reinforcing member See Attached Enercalc Reports Framing Check: East-West Screen Support (For Members w/o (E) Reinfocement) b(E) =3.5 in Width of existing beam d(E) =15.25 in Depth of existing beam IE) =1034.4 in 4 Moment of inertia of (E) member E(E) =1700 ksi Modulus of elasticity of (E) member IE(E) =2E+06 Product of moment of inertia and modulus of elasticty b(R) =1.75 in Width of (N) reinforcing member d(R) =11.87 in Depth of (N) reinforcing member IR) =243.9 in 4 Moment of inertia of (N) reinforcing member E(R) =1900 ksi Modulus of elasticity of (N) reinforcing member IE(R) =463407 Product of moment of inertia and modulus of elasticty IEtotal =3E+06 in 4 Sum of products (1 (E) member and 2 (E) reinforcing members) I(E)/Itotal =0.6549 Ratio of (E) member moment of interia/modulus of elastic product to sum I(R)/Itotal =0.1726 Ratio of (E) reinforcing member moment of interia/modulus of elastic product to sum PDL,m =251 lbs Dead load demand from roof screen framing acting on (E) member PDL,r =66 lbs Dead load demand from roof screen framing acting on (E) reinforcing member x =14 ft Location on span where demand acts Mwind,m =6154.6 lb-ft Moment demand on (E) member from lateral wind loading Mwind,r =1621.9 lb-ft Moment demand on (E) reinforcing member from lateral wind loading x =12 ft Location on span where demand acts DLm =9.8 psf Roof dead load on (E) member DLr =2.6 psf Roof dead load on (E) reinforcing member LLm =13.1 psf Roof live load on (E) member LLr =3.5 psf Roof live load on (E) reinforcing member See Attached Enercalc Reports BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH CHECK 2: 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Anchorage S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis Framing Check: North-South Screen Support (For Members w (E) Reinfocement) ybrace =4 ft Height at which brace frames into vertical member Rwind =1139.2 lbs Lateral reaction on brace xp =4.75 ft Distance from parapet to (E) beam H =8.5 ft Total height of windscreen ϴbrace =60.8 deg Brace angle Pwind =2038.6 lbs Vertical wind demand from brace force acting on framing x1 =8 ft Span location where demand acts x2 =16 ft Span location where demand acts L =22 ft Member span tw =6.4 ft Trib width of member I(E)/Itotal =0.5163 Ratio of (E) member moment of interia/modulus of elastic product to sum (See previous) I(R)/Itotal =0.2419 Ratio of (E) reinforcing member moment of interia/modulus of elastic product to sum (See previous) Pwind,m =1052.4 lbs Vertical wind demand from brace force acting on (E) main member Pwind,r =493.1 lbs Vertical wind demand from brace force acting on (E) reinforcing member x1 =8 ft Span location where demand acts x2 =16 ft Span location where demand acts See Attached Enercalc Reports BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH CHECK 3: 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Reinforced Check (EW Roof Screen Support) Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.00980, Lr = 0.01310 ksf, Tributary Width = 8.0 ft, (DL + LL) Point Load : D = 0.2510 k @ 14.0 ft, (Roof Screen) Moment : W = 6.154 k-ft, Location = 12.0 ft from left end of this span, (Moment Demand From Wind Screen) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.705: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 10.106ft 51.81 psi= = 1,250.00psi 4x16Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x16 Maximum Shear Stress Ratio 0.230 : 1 18.290 ft= = 881.08psi Maximum Deflection 3800 >=360 597 Ratio =0 <180 Max Downward Transient Deflection 0.195 in 1199Ratio = >=360 Max Upward Transient Deflection -0.062 in Ratio = Max Downward Total Deflection 0.391 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only Span: 1 : W Only Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 19.50 ft 1 0.491 0.165 0.90 1.000 1.001.00 1.00 4.99 441.8 900.0 0.95 162.01.00 26.71.00 1.00+D+Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.705 0.230 1.25 1.000 1.001.00 1.00 9.96 881.1 1,250.0 1.84 225.01.00 51.81.00 1.00+D+0.750Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.617 0.202 1.25 1.000 1.001.00 1.00 8.72 771.1 1,250.0 1.62 225.01.00 45.51.00 1.00+D+0.60W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.349 0.111 1.60 1.000 1.001.00 1.00 6.31 558.1 1,600.0 1.14 288.01.00 32.01.00 1.00+D-0.60W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 FOR CHECK 1 AND CHECK 2 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Reinforced Check (EW Roof Screen Support) Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 19.50 ft 1 0.396 0.100 1.60 1.000 1.001.00 1.00 7.17 634.0 1,600.0 1.03 288.01.00 28.91.00 1.00+D+0.750Lr+0.450W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.525 0.172 1.60 1.000 1.001.00 1.00 9.49 839.3 1,600.0 1.76 288.01.00 49.51.00 1.00+D+0.750Lr-0.450W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.565 0.161 1.60 1.000 1.001.00 1.00 10.22 904.1 1,600.0 1.65 288.01.00 46.41.00 1.00+D+0.450W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.329 0.106 1.60 1.000 1.001.00 1.00 5.96 526.8 1,600.0 1.09 288.01.00 30.61.00 1.00+D-0.450W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.365 0.096 1.60 1.000 1.001.00 1.00 6.60 584.0 1,600.0 0.98 288.01.00 27.61.00 1.00+0.60D+0.60W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.241 0.074 1.60 1.000 1.001.00 1.00 4.35 384.9 1,600.0 0.76 288.01.00 21.31.00 1.00+0.60D-0.60W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.288 0.068 1.60 1.000 1.001.00 1.00 5.21 460.5 1,600.0 0.69 288.01.00 19.51.00 1.00+0.60D 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.166 0.056 1.60 1.000 1.001.00 1.00 3.00 265.1 1,600.0 0.57 288.01.00 16.01.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.3914 9.892 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.970 2.079 Max Upward from Load Combinations 1.970 2.079 Max Upward from Load Cases 1.022 1.057 Max Downward from all Load Conditio -0.316 Max Downward from Load Cases (Resis -0.316 D Only 0.948 1.057 +D+Lr 1.970 2.079 +D+0.750Lr 1.714 1.824 +D+0.60W 0.759 1.247 +D+0.750Lr+0.450W 1.572 1.966 +D+0.450W 0.806 1.199 +0.60D+0.60W 0.379 0.824 +0.60D 0.569 0.634 Lr Only 1.022 1.022 W Only -0.316 0.316 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Reinforcing Member Check (EW Roof Screen Support) - (E) Reinf Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.00360, Lr = 0.00480 ksf, Tributary Width = 8.0 ft, (DL + LL) Point Load : D = 0.00930 k @ 14.0 ft, (Wind Screen) Moment : W = 2.273 k-ft, Location = 12.0 ft from left end of this span, (Wind Screen Moment Demand) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.519: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 9.750ft 29.55 psi= = 1,125.00psi 3x14Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 3x14 Maximum Shear Stress Ratio 0.131 : 1 18.432 ft= = 584.15psi Maximum Deflection 4820 >=360 785 Ratio =0 <180 Max Downward Transient Deflection 0.153 in 1534Ratio = >=360 Max Upward Transient Deflection -0.049 in Ratio = Max Downward Total Deflection 0.298 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only Span: 1 : W Only Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 19.50 ft 1 0.352 0.089 0.90 0.900 1.001.00 1.00 1.74 284.8 810.0 0.32 162.01.00 14.41.00 1.00+D+Lr 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.519 0.131 1.25 0.900 1.001.00 1.00 3.56 584.1 1,125.0 0.65 225.01.00 29.51.00 1.00+D+0.750Lr 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.453 0.115 1.25 0.900 1.001.00 1.00 3.10 509.3 1,125.0 0.57 225.01.00 25.81.00 1.00+D+0.60W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.247 0.061 1.60 0.900 1.001.00 1.00 2.17 356.1 1,440.0 0.39 288.01.00 17.61.00 1.00+D-0.60W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 FOR CHECK 1 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Reinforcing Member Check (EW Roof Screen Support) - (E) Reinf Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 19.50 ft 1 0.284 0.061 1.60 0.900 1.001.00 1.00 2.49 408.6 1,440.0 0.38 288.01.00 17.41.00 1.00+D+0.750Lr+0.450W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.380 0.098 1.60 0.900 1.001.00 1.00 3.33 547.0 1,440.0 0.62 288.01.00 28.11.00 1.00+D+0.750Lr-0.450W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.415 0.097 1.60 0.900 1.001.00 1.00 3.64 597.0 1,440.0 0.62 288.01.00 28.01.00 1.00+D+0.450W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.232 0.058 1.60 0.900 1.001.00 1.00 2.04 334.7 1,440.0 0.37 288.01.00 16.81.00 1.00+D-0.450W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.261 0.058 1.60 0.900 1.001.00 1.00 2.29 375.5 1,440.0 0.37 288.01.00 16.61.00 1.00+0.60D+0.60W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.172 0.041 1.60 0.900 1.001.00 1.00 1.51 248.0 1,440.0 0.26 288.01.00 11.81.00 1.00+0.60D-0.60W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.208 0.041 1.60 0.900 1.001.00 1.00 1.83 300.0 1,440.0 0.26 288.01.00 11.71.00 1.00+0.60D 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.119 0.030 1.60 0.900 1.001.00 1.00 1.04 170.9 1,440.0 0.19 288.01.00 8.71.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.2977 9.821 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.728 0.732 Max Upward from Load Combinations 0.728 0.732 Max Upward from Load Cases 0.374 0.374 Max Downward from all Load Conditio -0.117 Max Downward from Load Cases (Resis -0.117 D Only 0.353 0.357 +D+Lr 0.728 0.732 +D+0.750Lr 0.634 0.638 +D+0.60W 0.283 0.427 +D+0.750Lr+0.450W 0.582 0.691 +D+0.450W 0.301 0.410 +0.60D+0.60W 0.142 0.284 +0.60D 0.212 0.214 Lr Only 0.374 0.374 W Only -0.117 0.117 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Reinforcing Member Check (EW Roof Screen Support) - New Reinf Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist MicroLam LVL 1.9 E 2,600.0 2,600.0 2,510.0 750.0 1,900.0 965.71 285.0 1,555.0 42.010 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.00260, Lr = 0.00350 ksf, Tributary Width = 8.0 ft, (DL + LL) Point Load : D = 0.0660 k @ 14.0 ft, (Wind Screen) Moment : W = 1.621 k-ft, Location = 12.0 ft from left end of this span, (Wind Screen Moment Demand) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.250: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 10.106ft 38.37 psi= = 3,254.63psi 1.75x11.87Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 356.25 psi== Section used for this span 1.75x11.87 Maximum Shear Stress Ratio 0.108 : 1 18.575 ft= = 814.70psi Maximum Deflection 3806 >=360 562 Ratio =0 <180 Max Downward Transient Deflection 0.197 in 1185Ratio = >=360 Max Upward Transient Deflection -0.061 in Ratio = Max Downward Total Deflection 0.416 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only Span: 1 : W Only Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 19.50 ft 1 0.182 0.080 0.90 1.001 1.001.00 1.00 1.46 427.4 2,343.3 0.28 256.51.00 20.51.00 1.00+D+Lr 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.250 0.108 1.25 1.001 1.001.00 1.00 2.79 814.7 3,254.6 0.53 356.31.00 38.41.00 1.00+D+0.750Lr 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.221 0.095 1.25 1.001 1.001.00 1.00 2.46 717.8 3,254.6 0.47 356.31.00 33.91.00 1.00+D+0.60W 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.126 0.053 1.60 1.001 1.001.00 1.00 1.80 526.3 4,165.9 0.33 456.01.00 24.11.00 1.00+D-0.60W 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 FOR CHECK 2 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Reinforcing Member Check (EW Roof Screen Support) - New Reinf Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 19.50 ft 1 0.142 0.048 1.60 1.001 1.001.00 1.00 2.03 592.4 4,165.9 0.31 456.01.00 22.11.00 1.00+D+0.750Lr+0.450W 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.186 0.080 1.60 1.001 1.001.00 1.00 2.65 774.4 4,165.9 0.51 456.01.00 36.61.00 1.00+D+0.750Lr-0.450W 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.200 0.076 1.60 1.001 1.001.00 1.00 2.85 832.7 4,165.9 0.48 456.01.00 34.51.00 1.00+D+0.450W 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.120 0.051 1.60 1.001 1.001.00 1.00 1.71 499.1 4,165.9 0.32 456.01.00 23.21.00 1.00+D-0.450W 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.132 0.046 1.60 1.001 1.001.00 1.00 1.88 548.9 4,165.9 0.29 456.01.00 21.21.00 1.00+0.60D+0.60W 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.086 0.035 1.60 1.001 1.001.00 1.00 1.23 359.3 4,165.9 0.22 456.01.00 15.91.00 1.00+0.60D-0.60W 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.102 0.032 1.60 1.001 1.001.00 1.00 1.46 425.0 4,165.9 0.20 456.01.00 14.71.00 1.00+0.60D 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.50 ft 1 0.062 0.027 1.60 1.001 1.001.00 1.00 0.88 256.4 4,165.9 0.17 456.01.00 12.31.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.4158 9.892 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.554 0.582 Max Upward from Load Combinations 0.554 0.582 Max Upward from Load Cases 0.281 0.309 Max Downward from all Load Conditio -0.083 Max Downward from Load Cases (Resis -0.083 D Only 0.281 0.309 +D+Lr 0.554 0.582 +D+0.750Lr 0.485 0.514 +D+0.60W 0.231 0.359 +D+0.750Lr+0.450W 0.448 0.551 +D+0.450W 0.243 0.347 +0.60D+0.60W 0.118 0.235 +0.60D 0.168 0.186 Lr Only 0.273 0.273 W Only -0.083 0.083 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Reinforced Check (NS Roof Screen Support) Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.00770, Lr = 0.01030 ksf, Tributary Width = 6.40 ft, (DL + LL) Point Load : W = 1.052 k @ 8.0 ft, (Roof Screen) Point Load : W = 1.052 k @ 16.0 ft, (Roof Screen) Uniform Load : D = 0.06250 k/ft, Extent = 0.0 -->> 2.0 ft, Tributary Width = 1.0 ft, (Unit Demand) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.556: 1 Load Combination +D+0.750Lr+0.450W Span # where maximum occurs Span # 1 Location of maximum on span 10.518ft 36.14 psi= = 1,600.00psi 4x16Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x16 Maximum Shear Stress Ratio 0.161 : 1 0.000 ft= = 889.81psi Maximum Deflection 0 <360 521 Ratio =0 <180 Max Downward Transient Deflection 0.377 in 699Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.506 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : W Only n/a Span: 1 : +D+0.750Lr+0.450W n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 22.0 ft 1 0.368 0.111 0.90 1.000 1.001.00 1.00 3.74 331.2 900.0 0.64 162.01.00 18.01.00 1.00+D+Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.547 0.161 1.25 1.000 1.001.00 1.00 7.73 683.9 1,250.0 1.29 225.01.00 36.11.00 1.00+D+0.750Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.477 0.140 1.25 1.000 1.001.00 1.00 6.74 595.8 1,250.0 1.12 225.01.00 31.61.00 1.00+D+0.60W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.453 0.126 1.60 1.000 1.001.00 1.00 8.19 724.9 1,600.0 1.29 288.01.00 36.31.00 FOR CHECK 3 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Reinforced Check (NS Roof Screen Support) Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+D-0.60W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.065 0.038 1.60 1.000 1.001.00 1.00 1.17 103.6 1,600.0 0.39 288.01.00 11.11.00 1.00+D+0.750Lr+0.450W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.556 0.156 1.60 1.000 1.001.00 1.00 10.06 889.8 1,600.0 1.60 288.01.00 45.01.00 1.00+D+0.750Lr-0.450W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.189 0.068 1.60 1.000 1.001.00 1.00 3.43 303.2 1,600.0 0.69 288.01.00 19.51.00 1.00+D+0.450W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.391 0.109 1.60 1.000 1.001.00 1.00 7.08 626.0 1,600.0 1.12 288.01.00 31.41.00 1.00+D-0.450W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.032 0.026 1.60 1.000 1.001.00 1.00 0.57 50.6 1,600.0 0.27 288.01.00 7.51.00 1.00+0.60D+0.60W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.371 0.102 1.60 1.000 1.001.00 1.00 6.72 594.0 1,600.0 1.05 288.01.00 29.51.00 1.00+0.60D-0.60W 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.138 0.049 1.60 1.000 1.001.00 1.00 2.49 220.6 1,600.0 0.50 288.01.00 14.11.00 1.00+0.60D 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.124 0.037 1.60 1.000 1.001.00 1.00 2.25 198.7 1,600.0 0.38 288.01.00 10.81.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+0.750Lr+0.450W 1 0.5060 11.080 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.763 1.735 Max Upward from Load Combinations 1.763 1.735 Max Upward from Load Cases 0.956 1.148 D Only 0.789 0.675 +D+Lr 1.514 1.400 +D+0.750Lr 1.332 1.219 +D+0.60W 1.362 1.364 +D+0.750Lr+0.450W 1.763 1.735 +D+0.450W 1.219 1.191 +0.60D+0.60W 1.047 1.094 +0.60D 0.473 0.405 Lr Only 0.725 0.725 W Only 0.956 1.148 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Reinforced Check (NS Roof Screen Support) -Reinforcing Member Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.00360, Lr = 0.00480 ksf, Tributary Width = 6.40 ft, (DL + LL) Point Load : W = 0.4931 k @ 8.0 ft, (Roof Screen) Point Load : W = 0.4931 k @ 16.0 ft, (Roof Screen) Uniform Load : D = 0.06250 k/ft, Extent = 0.0 -->> 2.0 ft, Tributary Width = 1.0 ft, (Unit Demand) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.552: 1 Load Combination +D+0.750Lr+0.450W Span # where maximum occurs Span # 1 Location of maximum on span 10.518ft 29.92 psi= = 1,440.00psi 3x14Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 3x14 Maximum Shear Stress Ratio 0.133 : 1 0.000 ft= = 794.67psi Maximum Deflection 0 <360 507 Ratio =0 <180 Max Downward Transient Deflection 0.377 in 699Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.520 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : W Only n/a Span: 1 : +D+0.750Lr+0.450W n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 22.0 ft 1 0.383 0.099 0.90 0.900 1.001.00 1.00 1.89 310.3 810.0 0.35 162.01.00 16.11.00 1.00+D+Lr 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.547 0.133 1.25 0.900 1.001.00 1.00 3.75 615.1 1,125.0 0.66 225.01.00 29.91.00 1.00+D+0.750Lr 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.479 0.118 1.25 0.900 1.001.00 1.00 3.28 538.9 1,125.0 0.58 225.01.00 26.51.00 1.00+D+0.60W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.453 0.099 1.60 0.900 1.001.00 1.00 3.98 652.8 1,440.0 0.63 288.01.00 28.51.00 FOR CHECK 3 3009 S Daimler St 11/18/2024 Wood Beam LIC# : KW-06017366, Build:20.24.03.04 B&J HBK, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:(E) 4x16 Reinforced Check (NS Roof Screen Support) -Reinforcing Member Project File: 3009 Daimler Cath Lab.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+D-0.60W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.051 0.029 1.60 0.900 1.001.00 1.00 0.45 73.7 1,440.0 0.18 288.01.00 8.31.00 1.00+D+0.750Lr+0.450W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.552 0.124 1.60 0.900 1.001.00 1.00 4.84 794.7 1,440.0 0.79 288.01.00 35.61.00 1.00+D+0.750Lr-0.450W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.197 0.060 1.60 0.900 1.001.00 1.00 1.73 284.3 1,440.0 0.38 288.01.00 17.31.00 1.00+D+0.450W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.394 0.088 1.60 0.900 1.001.00 1.00 3.46 566.8 1,440.0 0.56 288.01.00 25.21.00 1.00+D-0.450W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.044 0.024 1.60 0.900 1.001.00 1.00 0.38 62.9 1,440.0 0.15 288.01.00 6.91.00 1.00+0.60D+0.60W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.368 0.080 1.60 0.900 1.001.00 1.00 3.23 530.0 1,440.0 0.51 288.01.00 22.91.00 1.00+0.60D-0.60W 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.124 0.036 1.60 0.900 1.001.00 1.00 1.09 178.2 1,440.0 0.23 288.01.00 10.31.00 1.00+0.60D 0.900 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 22.0 ft 1 0.129 0.033 1.60 0.900 1.001.00 1.00 1.13 186.2 1,440.0 0.21 288.01.00 9.61.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+0.750Lr+0.450W 1 0.5205 11.000 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.907 0.834 Max Upward from Load Combinations 0.907 0.834 Max Upward from Load Cases 0.452 0.538 D Only 0.452 0.338 +D+Lr 0.790 0.676 +D+0.750Lr 0.705 0.592 +D+0.60W 0.721 0.661 +D+0.750Lr+0.450W 0.907 0.834 +D+0.450W 0.653 0.580 +0.60D+0.60W 0.540 0.526 +0.60D 0.271 0.203 Lr Only 0.338 0.338 W Only 0.448 0.538 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA - S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis Roof Screen Design BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 Roof Screen Design Demand DLscreen =8 psf Dead load of roof screen pwind =35.6 psf Wind demand (See calculations) Roof Screen At Parapet Wind Screen Design tw =8 ft Tributary width for lateral wind demand wwind =284.8 plf Wind demand on vertical member See Attached Risa 3D Model Anchorage Tu =664 lbs Worst case tensile demand in anchorage (See node reactions) Vu,x =1091 lbs Worst case shear demand in anchorage (See node reactions) Vu,z =1366 lbs Worst case shear demand in anchorage (See node reactions) See Attached Anchorage Calculations Typical Roof Screen Wind Screen Design tw =8 ft Tributary width for lateral wind demand wwind =284.8 plf Wind demand on vertical member See Attached Risa 3D Model Anchorage Tu =1698 lbs Worst case tensile demand in anchorage (See node reactions) Vu,z =926 lbs Worst case shear demand in anchorage (See node reactions) Mu =617 lb-ft Worst case moment demand in anchorage (See node reactions) danchors =8 in Distance between anchors resisting moment demand Tu,moment =925.5 lbs Additional tensile demand in anchors from moment demand T/C couple Tmax =1574.1 lbs Worst case design tensile demand (ASD) Vmax,z =555.6 lbs Worst case design shear demand (ASD) See Lag Screw Design PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Anchorage S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA Anchorage S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis Baseplate Design Demand L =11 in Total length of baseplate W =3.5 in Total width of baseplate dedge =1.5 in Distance from edge of plate to bolt CL Lb =4 in Length of plate in bending Pu =1574.1 lbs Ultimate uplift demand at anchor location Mu =6296.4 lb-in Flexural demand baseplate critical section Capacity Fy =36 ksi Yield strength of plate t =0.625 in Thickness of plate Zx =0.3418 in 3 Section modulus of baseplate ɸMn =12305 lb-in Flexural capacity of section O.K. Roof Screen At Parapet Alternate Anchorage Tu =1710 lbs Worst case tensile demand in anchorage (See node reactions) Vu,x =491 lbs Worst case shear demand in anchorage (See node reactions) Vu,z =1300 lbs Worst case shear demand in anchorage (See node reactions) See Attached Anchorage Calculations BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 PROJECT PROJECT NO. ITEM Marina Landscape - HVAC Replacement RTU Unit Anchorage ENGINEER DATE SHEET NO. CL S23-0086 Wood Lag Screw Design Vc =556 lb/conn Tc =1574 lb/conn Design Criteria R α Load: 1669 lb @ 70.6 °Vector Load from V b and T b Main Member Species:Douglas Fir-Larch Main Member Thickness:15-1/4 in Side Member Thickness:1/4 in G = 0.50 Specific gravity D = 0.75 in Diameter of lag screw L = 7 in Length of lag screw pz =6.25 in Shear penetration pw =3.50 in Withdrawal penetration From Table Z multiplier (Note 3) Z =600 x 1 Ref. NDS-2018 Table 12J - 11K Allowable Lateral Load Capacity Ref. NDS-2018 Table 11.3.1 Z CD CM Ct Cg C∆Ceg Cdi Ctn Z' =600 1.6 1 1 1 1 1 1 1 =960 lb Allowable Withdrawal Load Capacity Ref. NDS-2018 Table 11.3.1 W CD CM Ct Ceg Ctn W' =513 1.6 1 1 1 1 = 821 lb/in W' x pw = 2872 lb Allowable Vector Load Capacity Demand / Capacity Ref. NDS-2018 §12.4.1 Z'α = 2353 lb OK Ref. NDS-2018 Eq.12.4-1 Use 3/4'' diameter 7'' long lag screw Douglas Fir-Larch 0.75 7 BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Page: Specifier: E-Mail: Date: 1 9/24/2024 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - CS 1/2 (3 1/4) Item number: 2210255 KB-TZ2 1/2x4 1/2 Specification text: Hilti KB-TZ2 stud anchor with 3.75 in embedment, 1/2 (3 1/4), Carbon steel, installation per ESR-4266 Effective embedment depth: hef,act = 3.250 in., hnom = 3.750 in. Material: Carbon Steel Evaluation Service Report: ESR-4266 Issued I Valid: 12/1/2023 | 12/1/2025 Proof: Design Method ACI 318-19 / Mech Stand-off installation: Profile: Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 6.000 in. Installation: Hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Page: Specifier: E-Mail: Date: 2 9/24/2024 Geometry [in.] & Loading [lb, in.lb] 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Page: Specifier: E-Mail: Date: 3 9/24/2024 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 664; Vx = 1,091; Vy = 1,366; Mx = 0; My = 0; Mz = 0; no 89 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 664 1,748 1,091 1,366 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*664 8,433 8 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**664 2,788 24 OK * highest loaded anchor **anchor group (anchors in tension) 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Page: Specifier: E-Mail: Date: 4 9/24/2024 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4266 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.10 114,004 Calculations Nsa [lb] 11,244 Results Nsa [lb]f steel f Nsa [lb]Nua [lb] 11,244 0.750 8,433 664 3.2 Concrete Breakout Failure Ncb = (ANc ANc0)y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1a) f Ncb ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ca,min [in.]y c,N cac [in.]kc l a f' c [psi] 3.250 4.000 1.000 10.000 17 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 86.53 95.06 0.946 1.000 4,980 Results Ncb [lb]f concrete f Ncb [lb]Nua [lb] 4,289 0.650 2,788 664 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Page: Specifier: E-Mail: Date: 5 9/24/2024 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*1,748 4,471 40 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**1,748 6,005 30 OK Concrete edge failure in direction y+**1,748 2,015 87 OK * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa = ESR value refer to ICC-ES ESR-4266 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi] 0.10 114,004 Calculations Vsa [lb] 6,878 Results Vsa [lb]f steel f Vsa [lb]Vua [lb] 6,878 0.650 4,471 1,748 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Page: Specifier: E-Mail: Date: 6 9/24/2024 4.2 Pryout Strength Vcp = kcp [(ANc ANc0)y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1a) f Vcp ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ca,min [in.]y c,N 2 3.250 4.000 1.000 cac [in.]kc l a f' c [psi] 10.000 17 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 86.53 95.06 0.946 1.000 4,980 Results Vcp [lb]f concrete f Vcp [lb]Vua [lb] 8,578 0.700 6,005 1,748 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Page: Specifier: E-Mail: Date: 7 9/24/2024 4.3 Concrete edge failure in direction y+ Vcb = (AVc AVc0)y ed,V y c,V y h,V y parallel,V Vb ACI 318-19 Eq. (17.7.2.1a) f Vcb ³ Vua ACI 318-19 Table 17.5.2 AVc see ACI 318-19, Section 17.7.2.1, Fig. R 17.7.2.1(b) AVc0 = 4.5 c2 a1 ACI 318-19 Eq. (17.7.2.1.3) y ed,V = 0.7 + 0.3(ca2 1.5ca1)£ 1.0 ACI 318-19 Eq. (17.7.2.4.1b) y h,V = √1.5ca1 ha ³ 1.0 ACI 318-19 Eq. (17.7.2.6.1) Vb = (7 (le da)0.2 √da)l a √f' c c1.5 a1 ACI 318-19 Eq. (17.7.2.2.1a) Variables ca1 [in.]ca2 [in.]y c,V ha [in.]le [in.] 4.000 -1.000 6.000 3.250 l a da [in.]f' c [psi]y parallel,V 1.000 0.500 2,500 1.000 Calculations AVc [in.2]AVc0 [in.2]y ed,V y h,V Vb [lb] 72.00 72.00 1.000 1.000 2,879 Results Vcb [lb]f concrete f Vcb [lb]Vua [lb] 2,879 0.700 2,015 1,748 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.238 0.868 5/3 89 OK bNV = bz N + bz V <= 1 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Page: Specifier: E-Mail: Date: 8 9/24/2024 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 9 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Page: Specifier: E-Mail: Date: 9 9/24/2024 7 Installation data Anchor type and diameter: Kwik Bolt TZ2 - CS 1/2 (3 1/4) Profile: - Item number: 2210255 KB-TZ2 1/2x4 1/2 Hole diameter in the fixture: - Maximum installation torque: 602 in.lb Plate thickness (input): - Hole diameter in the base material: 0.500 in. Hole depth in the base material: 4.250 in. Drilling method: Hammer drilled Minimum thickness of the base material: 5.500 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti KB-TZ2 stud anchor with 3.75 in embedment, 1/2 (3 1/4), Carbon steel, installation per ESR-4266 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool • Torque wrench • Hammer Coordinates Anchor in. Anchor x y c-x c+x c-y c+y 1 0.000 0.000 ---4.000 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 10 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Page: Specifier: E-Mail: Date: 10 9/24/2024 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Alternate Page: Specifier: E-Mail: Date: 1 9/25/2024 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - CS 1/2 (3 1/4) Item number: 2210256 KB-TZ2 1/2x5 1/2 Specification text: Hilti KB-TZ2 stud anchor with 3.75 in embedment, 1/2 (3 1/4), Carbon steel, installation per ESR-4266 Effective embedment depth: hef,act = 3.250 in., hnom = 3.750 in. Material: Carbon Steel Evaluation Service Report: ESR-4266 Issued I Valid: 12/1/2023 | 12/1/2025 Proof: Design Method ACI 318-19 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plateR : lx x ly x t = 10.000 in. x 4.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 6.000 in. Installation: Hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, in.lb] 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Alternate Page: Specifier: E-Mail: Date: 2 9/25/2024 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 1,710; Vx = 491; Vy = 1,300; Mx = 0; My = 0; Mz = 0; no 44 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 570 463 164 433 2 570 463 164 433 3 570 463 164 433 Max. concrete compressive strain: - [‰] Max. concrete compressive stress: - [psi] Resulting tension force in (x/y)=(0.000/0.000): 1,710 [lb] Resulting compression force in (x/y)=(-/-): 0 [lb] Anchor forces are calculated based on the assumption of a rigid anchor plate. 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*570 8,433 7 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**1,710 4,790 36 OK * highest loaded anchor **anchor group (anchors in tension) 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Alternate Page: Specifier: E-Mail: Date: 3 9/25/2024 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4266 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.10 114,004 Calculations Nsa [lb] 11,244 Results Nsa [lb]f steel f Nsa [lb]Nua [lb] 11,244 0.750 8,433 570 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Alternate Page: Specifier: E-Mail: Date: 4 9/25/2024 3.2 Concrete Breakout Failure Ncbg = (ANc ANc0)y ec,N y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1b) f Ncbg ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ec,N = (1 1 + 2 e' N 3 hef )£ 1.0 ACI 318-19 Eq. (17.6.2.3.1) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ec1,N [in.]ec2,N [in.]ca,min [in.]y c,N 3.250 0.000 0.000 4.000 1.000 cac [in.]kc l a f' c [psi] 10.000 17 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ec1,N y ec2,N y ed,N y cp,N Nb [lb] 148.66 95.06 1.000 1.000 0.946 1.000 4,980 Results Ncbg [lb]f concrete f Ncbg [lb]Nua [lb] 7,369 0.650 4,790 1,710 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Alternate Page: Specifier: E-Mail: Date: 5 9/25/2024 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*463 4,471 11 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**1,390 10,316 14 OK Concrete edge failure in direction y+**1,390 3,191 44 OK * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa = ESR value refer to ICC-ES ESR-4266 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi] 0.10 114,004 Calculations Vsa [lb] 6,878 Results Vsa [lb]f steel f Vsa [lb]Vua [lb] 6,878 0.650 4,471 463 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Alternate Page: Specifier: E-Mail: Date: 6 9/25/2024 4.2 Pryout Strength Vcpg = kcp [(ANc ANc0)y ec,N y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1b) f Vcpg ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ec,N = (1 1 + 2 e' N 3 hef )£ 1.0 ACI 318-19 Eq. (17.6.2.3.1) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ec1,N [in.]ec2,N [in.]ca,min [in.] 2 3.250 0.000 0.000 4.000 y c,N cac [in.]kc l a f' c [psi] 1.000 10.000 17 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ec1,N y ec2,N y ed,N y cp,N Nb [lb] 148.66 95.06 1.000 1.000 0.946 1.000 4,980 Results Vcpg [lb]f concrete f Vcpg [lb]Vua [lb] 14,737 0.700 10,316 1,390 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Alternate Page: Specifier: E-Mail: Date: 7 9/25/2024 4.3 Concrete edge failure in direction y+ Vcbg = (AVc AVc0)y ec,V y ed,V y c,V y h,V y parallel,V Vb ACI 318-19 Eq. (17.7.2.1b) f Vcbg ³ Vua ACI 318-19 Table 17.5.2 AVc see ACI 318-19, Section 17.7.2.1, Fig. R 17.7.2.1(b) AVc0 = 4.5 c2 a1 ACI 318-19 Eq. (17.7.2.1.3) y ec,V = (1 1 + e' v 1.5ca1 )£ 1.0 ACI 318-19 Eq. (17.7.2.3.1) y ed,V = 0.7 + 0.3(ca2 1.5ca1)£ 1.0 ACI 318-19 Eq. (17.7.2.4.1b) y h,V = √1.5ca1 ha ³ 1.0 ACI 318-19 Eq. (17.7.2.6.1) Vb = (7 (le da)0.2 √da)l a √f' c c1.5 a1 ACI 318-19 Eq. (17.7.2.2.1a) Variables ca1 [in.]ca2 [in.]ecV [in.]y c,V ha [in.] 4.000 -0.000 1.000 6.000 le [in.]l a da [in.]f' c [psi]y parallel,V 3.250 1.000 0.500 2,500 1.000 Calculations AVc [in.2]AVc0 [in.2]y ec,V y ed,V y h,V Vb [lb] 114.00 72.00 1.000 1.000 1.000 2,879 Results Vcbg [lb]f concrete f Vcbg [lb]Vua [lb] 4,558 0.700 3,191 1,390 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.357 0.436 5/3 43 OK bNV = bz N + bz V <= 1 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Alternate Page: Specifier: E-Mail: Date: 8 9/25/2024 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 9 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Alternate Page: Specifier: E-Mail: Date: 9 9/25/2024 Coordinates Anchor [in.] Anchor x y c-x c+x c-y c+y 1 -3.500 0.000 ---4.000 2 -0.000 0.000 ---4.000 3 3.500 0.000 ---4.000 7 Installation data Anchor type and diameter: Kwik Bolt TZ2 - CS 1/2 (3 1/4) Profile: no profile Item number: 2210256 KB-TZ2 1/2x5 1/2 Hole diameter in the fixture: df = 0.562 in. Maximum installation torque: 602 in.lb Plate thickness (input): 0.500 in. Hole diameter in the base material: 0.500 in. Recommended plate thickness: not calculated Hole depth in the base material: 4.250 in. Drilling method: Hammer drilled Minimum thickness of the base material: 5.500 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti KB-TZ2 stud anchor with 3.75 in embedment, 1/2 (3 1/4), Carbon steel, installation per ESR-4266 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool • Torque wrench • Hammer 3009 S Daimler St 11/18/2024 www.hilti.com Hilti PROFIS Engineering 3.1.3 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 10 Company: Address: Phone I Fax: Design: Fastening point: | Wind Screeen At Parapet Anchorage Alternate Page: Specifier: E-Mail: Date: 10 9/25/2024 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 3009 S Daimler St 11/18/2024 PROJECT CLIENT LOCATION ITEM Edwards Advanced Catheter Lab TI TDA Architects Santa Ana, CA - S24-0082 SHEET # ENGINEER DATE JOB # 7/22/2024 C. Landis Risa 3D Model BRANDOW & JOHNSTON STRUCTURAL & CIVIL ENGINEERS | LOS ANGELES NEWPORT BEACH 3009 S Daimler St 11/18/2024 <Licensed Company> CLandis 3D Model SK-1 Sep 25, 2024 at 11:47 AM Wind Screen Brace Check.r3d WIND SCREEN AT PARAPET TYPICAL WIND SCREEN WIND SCREEN AT PARAPET ALTERNATE 3009 S Daimler St 11/18/2024 <Licensed Company> CLandis Member/Node Labels SK-2 Sep 25, 2024 at 11:48 AM Wind Screen Brace Check.r3d 3009 S Daimler St 11/18/2024 <Licensed Company> CLandis Wind Load SK-3 Sep 25, 2024 at 11:48 AM Wind Screen Brace Check.r3d 3009 S Daimler St 11/18/2024 <Licensed Company> CLandis Envelope Code Check SK-4 Sep 25, 2024 at 11:49 AM Wind Screen Brace Check.r3d 3009 S Daimler St 11/18/2024 Company Designer Job Number Model Name : : : : <Licensed Company> CLandis Checked By : __________ 9/25/2024 11:49:40 AM RISA-3D Version 22 [ Wind Screen Brace Check.r3d ] Page 1 Node Coordinates Label X [ft] Y [ft] Z [ft] Detach From Diaphragm 1 N1 0 0 0 2 N2 0 0.25 0 3 N3 0 0.67 0 4 N4 0 7 0 5 N5 0 5 0 6 N6 0 0 4.75 7 N7 0 4 0 8 N8 0 1 0 9 N9 8 -0.833 0 10 N10 8 7 0 11 N11 8 5 0 12 N12 8 -0.833 4.75 13 N13 8 4 0 14 N14 8 1 0 15 N15 8 -1.5 0 16 N16 8 -1.5 4.75 17 N17 -8 0.25 0 18 N18 -8 0.67 0 19 N19 -8 7 0 20 N20 -8 5 0 21 N21 -8 0 4.75 22 N22 -8 4 0 23 N23 -8 1 0 24 N24 -8 0 0 Hot Rolled Steel Properties Label E [ksi] G [ksi] Nu Therm. Coeff. [1e⁵°F⁻¹] Density [k/ft³] Yield [ksi] Ry Fu [ksi] Rt 1 A992 29000 11154 0.3 0.65 0.49 50 1.1 65 1.1 2 A36 Gr.36 29000 11154 0.3 0.65 0.49 36 1.5 58 1.2 3 A572 Gr.50 29000 11154 0.3 0.65 0.49 50 1.1 65 1.1 4 A500 Gr.B RND 29000 11154 0.3 0.65 0.527 42 1.4 58 1.3 5 A500 Gr.B RECT 29000 11154 0.3 0.65 0.527 46 1.4 58 1.3 6 A500 Gr.C RND 29000 11154 0.3 0.65 0.527 46 1.4 62 1.3 7 A500 Gr.C RECT 29000 11154 0.3 0.65 0.527 50 1.4 62 1.3 8 A53 Gr.B 29000 11154 0.3 0.65 0.49 35 1.6 60 1.2 9 A1085 29000 11154 0.3 0.65 0.49 50 1.4 65 1.3 10 A913 Gr.65 29000 11154 0.3 0.65 0.49 65 1.1 80 1.1 Hot Rolled Steel Section Sets Label Shape Type Design List Material Design Rule Area [in²] Iyy [in⁴] Izz [in⁴] J [in⁴] 1 Brace Angle L4X4X4 HBrace Single Angle A36 Gr.36 Typical 1.93 3 3 0.044 2 Post Angle L4X4X4 Column Single Angle A36 Gr.36 Typical 1.93 3 3 0.044 3 Horiz Angle L4X4X4 Beam Single Angle A36 Gr.36 Typical 1.93 3 3 0.044 4 HSS Post HSS3.000X0.250 Column HSS Pipe A500 Gr.C RND Typical 2.03 1.95 1.95 3.9 Nodal Loads and Enforced Displacements No Data to Print... 3009 S Daimler St 11/18/2024 Company Designer Job Number Model Name : : : : <Licensed Company> CLandis Checked By : __________ 9/25/2024 11:49:40 AM RISA-3D Version 22 [ Wind Screen Brace Check.r3d ] Page 2 Member Point Loads No Data to Print... Member Distributed Loads (BLC 2 : W) Member LabelDirectionStart Magnitude [k/ft, F, ksf, k-ft/ft]End Magnitude [k/ft, F, ksf, k-ft/ft]Start Location [(ft, %)]End Location [(ft, %)] 1 M2 Z 0.285 0.285 1 7 2 M7 Z 0.285 0.285 0 6 3 M10 Z 0.285 0.285 0 6 Member Area Loads No Data to Print... Basic Load Cases BLC Description Category Y Gravity Distributed 1 DL DL -1 2 W WL 3 Load Combinations Description Solve P-Delta BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor 1 Deflection 1 Yes Y DL 1 2 Deflection 2 Yes Y LL 1 3 Deflection 3 Yes Y DL 1 LL 1 4 ASCE Strength 1 Yes Y DL 1.4 5 ASCE Strength 2 (a)Yes Y DL 1.2 LL 1.6 LLS 1.6 RLL 0.5 6 ASCE Strength 2 (b)Yes Y DL 1.2 LL 1.6 LLS 1.6 7 ASCE Strength 3 (a)Yes Y DL 1.2 RLL 1.6 LL 0.5 LLS 1 8 ASCE Strength 3 (b) (a)Yes Y DL 1.2 RLL 1.6 WL 0.5 9 ASCE Strength 3 (b) (b)Yes Y DL 1.2 RLL 1.6 WL -0.5 10 ASCE Strength 3 (d) (a)Yes Y DL 1.2 WL 0.5 11 ASCE Strength 3 (d) (b)Yes Y DL 1.2 WL -0.5 12 ASCE Strength 4 (a) (a)Yes Y DL 1.2 WL 1 LL 0.5 LLS 1 RLL 0.5 13 ASCE Strength 4 (a) (b)Yes Y DL 1.2 WL -1 LL 0.5 LLS 1 RLL 0.5 14 ASCE Strength 4 (b) (a)Yes Y DL 1.2 WL 1 LL 0.5 LLS 1 15 ASCE Strength 4 (b) (b)Yes Y DL 1.2 WL -1 LL 0.5 LLS 1 16 ASCE Strength 5 (a)Yes Y DL 0.9 WL 1 17 ASCE Strength 5 (b)Yes Y DL 0.9 WL -1 Envelope Node Reactions Node Label X [k] LC Y [k] LC Z [k] LC MX [k-ft] LC MY [k-ft]LC MZ [k-ft] LC 1 N4 max 0.03 16 0 17 0 17 0 17 0 17 0 17 2 min -0.029 13 0 1 0 1 0 1 0 1 0 1 3 N7 max 0.072 17 0 17 0 17 0 17 0 17 0 17 4 min -0.073 12 0 1 0 1 0 1 0 1 0 1 5 N8 max 0.708 14 0 17 0 17 0 17 0 17 0 17 6 min -0.709 17 0 1 0 1 0 1 0 1 0 1 7 N3 max 1.091 17 1.366 15 0.664 15 0 17 0 17 0 17 8 min -1.089 12 -1.232 16 -0.661 16 0 1 0 1 0 1 9 N6 max 0 17 1.336 14 0 17 0 17 0 17 0 17 10 min 0 2 -1.256 17 0 1 0 1 0 1 0 1 11 N16 max 0 4 1.793 14 0.926 15 0.617 15 0 14 0 15 12 min 0 13 -1.698 17 -0.924 12 -0.617 12 0 13 0 8 13 N15 max 0.242 14 1.855 15 0.783 17 0.523 15 0 15 0.167 15 3009 S Daimler St 11/18/2024 Company Designer Job Number Model Name : : : : <Licensed Company> CLandis Checked By : __________ 9/25/2024 11:49:40 AM RISA-3D Version 22 [ Wind Screen Brace Check.r3d ] Page 3 Envelope Node Reactions (Continued) Node Label X [k] LC Y [k] LC Z [k] LC MX [k-ft] LC MY [k-ft] LC MZ [k-ft] LC 14 min -0.25 13 -1.652 16 -0.785 16 -0.523 12 0 12 -0.161 12 15 N10 max 0.001 14 0 17 0 17 0 17 0 17 0 17 16 min -0.004 13 0 1 0 1 0 1 0 1 0 1 17 N13 max 0.145 14 0 17 0 17 0 17 0 17 0 17 18 min -0.145 13 0 1 0 1 0 1 0 1 0 1 19 N14 max 0.399 15 0 17 0 17 0 17 0 17 0 17 20 min -0.389 12 0 1 0 1 0 1 0 1 0 1 21 N2 max 0.424 16 0.029 4 1.045 17 0 17 0 17 0 17 22 min -0.425 13 0 2 -1.048 12 0 1 0 1 0 1 23 N19 max 0.043 15 0 17 0 17 0 17 0 17 0 17 24 min -0.044 16 0 1 0 1 0 1 0 1 0 1 25 N22 max 0.034 14 0 17 0 17 0 17 0 17 0 17 26 min -0.033 17 0 1 0 1 0 1 0 1 0 1 27 N23 max 0.497 16 0 17 0 17 0 17 0 17 0 17 28 min -0.501 13 0 1 0 1 0 1 0 1 0 1 29 N18 max 0.491 15 1.3 15 1.71 15 0 17 0 17 0 17 30 min -0.486 16 -1.123 16 -1.71 12 0 1 0 1 0 1 31 N21 max 0 2 1.244 14 0 17 0 17 0 17 0 17 32 min 0 17 -1.165 17 0 1 0 1 0 1 0 1 33 Totals:max 0 14 0.542 4 5.128 17 34 min 0 13 0 2 -5.128 16 Envelope AISC 15TH (360-16): ASD Member Steel Code Checks Member Shape Code CheckLoc[ft]LCShear CheckLoc[ft]DirLCPnc/om [k]Pnt/om [k]Mnyy/om [k-ft]Mnzz/om [k-ft] Cb Eqn 1 M1 L4X4X4 0.058 1.979 15 0.003 4.75 y 15 29.245 41.605 2.088 4.07 1.117 H2-1 2 M2 L4X4X4 0.329 4.958 15 0.095 0.219 z 17 22.699 41.605 2.088 3.985 1.5 H2-1 3 M3 L4X4X4 0.093 3.376 14 0.002 6.897 y 4 23.106 41.605 2.088 3.732 1.15 H2-1 4 M4 HSS3.000X0.250 0.166 0 14 0.055 0.667 14 55.666 55.916 4.109 4.109 1 H1-1b 5 M5 HSS3.000X0.250 0.15 0 15 0.049 0.667 15 55.666 55.916 4.109 4.109 1 H1-1b 6 M6 L4X4X4 0.127 3.84 14 0.002 7.522 y 4 20.667 41.605 2.088 3.624 1.136 H2-1 7 M7 L4X4X4 0.418 4.814 15 0.065 2.04 z 15 19.483 41.605 2.088 3.727 1.299 H2-1 8 M8 L4X4X4 0.028 2.375 15 0.002 4.75 y 15 29.245 41.605 2.088 4.086 1.136 H2-1 9 M9 L4X4X4 0.087 3.376 14 0.002 6.897 y 4 23.106 41.605 2.088 3.73 1.148 H2-1 10 M10 L4X4X4 0.428 6.271 15 0.088 6.708 z 17 22.699 41.605 2.088 3.985 1.5 H2-1 11 M11 L4X4X4 0.055 1.979 15 0.004 4.75 y 14 29.245 41.605 2.088 4.07 1.117 H2-1 3009 S Daimler St 11/18/2024