Loading...
HomeMy WebLinkAbout2726 W Strawberry Ln & Unit# 2 - Plan O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area to Total Resulting Stories: Area Added in Past 2 Years Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed (PR400-402) Fire Sprinkler   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR 2726 W Strawberry Ln & Unit# 23/17/2025 P R O JE C T I N FO R M A T I O N : A P P LI C A B LE C O D E A LL W O R K S H A LL C O M P LY W I TH LO C A L B U I LD I N G C O D ES A M EN D M EN TS O F S H E E T S A S S H O W N V I C I N I TY M A P N O R TH FI R E S P R I N K L E R : * 2 02 2 C A LI FO R N I A EN ER G Y C O D E * 2 02 2 C A LI FO R N I A FI R E C O D E * 2 02 2 C A LI FO R N I A P LU M B I N G C O D E * 2 02 2 C A LI FO R N I A M EC H A N I C A L C O D E * 2 02 2 C A LI FO R N I A ELEC TR I C A L C O D E * 2 02 2 C .R .C * 2 02 2 C A LI FO R N I A B U I LD I N G C O D E A LL W O R K S H A LL C O M P LY W I TH TH E FO LLO W I N G C A LI FO R N I A C O D ES : N O S C A L E S H EET I N D EX N o . E x p . C I V I L R E G I S T E RED P R O F E S S I ONAL ENG I N E E R STATE OF C A L I FORNIA MINH V. TRAN 6 52 50 9-30-25 m i n h v a n t r a n 1 0 @ y a h o o . c o m 7 1 4 - 7 2 6 - 5 1 7 5 F O U N T A I N V A L L E Y C A 9 2 7 0 8 1 8 8 9 1 S A N C A R L O S S T . M I N H V . T R A N FI R E S P R I N K L E R : N O T R E Q U I R E D S E P A R A T E P E R M I T (S )/A P P L I C A T I O N (S ) 4 . S O L A R P A N E L 3. P LU M B I N G W O R K 2 . M EC H A N I C A L W O R K 1 . ELEC TR I C A L W O R K R O O F P LA N S , V EN T C A LC U LA TI O N , W I N D O W / D O O R S C H ED U LE S I TE P LA N , LO T C O V ER A G E, A N D FLO O R A R EA R A TI O 2 0 2 2 C A L I F O R N I A G R E E N B U I L D I N G S T A N D A R D C O M P L I A N C E 2 0 2 2 C A L I F O R N I A G R E E N R E S I D E N T I A L P R O J E C T C H E C K L I S T H E R S R A T E R V E R I FI C A T I O N : * V ER I FI ED D U C T D ES I G N * D U C T LEA K A G E TES TI N G * V ER I FI ED H EA T P U M P R A TED H EA TI N G C A P A C I TY * FA N EFFI C A C Y W A TTS / C FM * V ER I FI ED R EFR I G ER A N T C H A R G E * V E R I FI E D S E E R / S E E R 2 * V E R I FI E D E E R / E E R 2 * M IN IM U M A IRFLO W * K I TC H EN R A N G E H O O D * IN D O O R A IR Q U A LITY V EN TILA TIO N * Q U A LITY IN S U LA TIO N IN S TA LLA TIO N (Q II) TH E FO LLO W I N G I S A S U M M A R Y O F TH E FEA TU R ES TH A T M U S T B E FI ELD -V ER I FI ED B Y A C ER TI FI ED H ER S R A TER S : R EV IS IO N S B Y B Y T H E I N S P E C T O R . A N D P LU M B I N G C O D E C O M P LI A N C E A N D TH ES E D I S C I P LI N ES A R E S U B JEC T TO FI ELD I N S P EC TI O N A N D A P P R O V A L TH E P LA N S FO R S I N G LE FA M I LY D W ELLI N G S A N D D U P LEX ES A R E N O T C H EC K ED FO R ELEC TR I C A L, M EC H A N I C A L, 1 S C O P E O F W O R K S EX I S TI N G FLO O R P LA N A D U FLO O R P LA N T H E N E A R E S T B U S S T O P 0 .3 M I L E S W A L K IN G D IS T A N C E B Y M IL E S T O Z O N I N G = R -1 L O T S I Z E = 1 1 ,6 4 6 S .F N U M B E R O F S T O R Y : 1 C O N T A C T P H O N E N O .: 7 1 4 -8 5 6 -2 1 2 1 A D D R E S S : 2 7 2 6 S T R A W B E R R Y L A N E , S A N T A A N A , 9 2 7 06 O W N ER : JA M ES D U N G P H A M & JO Y C E N G A P H A M A P N : 1 01 - 1 2 1 - 2 8 O F T H E C O U N T Y R E C O R D E R O F S A I D C O U N T Y . A S P E R M A P R E C O R D E D I N B O O K 4 1 , P A G E 1 4 , P A G E 2 7 O F M I S C E L L A N E O U S M A P S , I N T H E O FFI C E LO T 32 O F TR A C T N O . 1 351 , I N TH E C I TY O F S A N TA A N A , C O U N TY O F O R A N G E, S TA TE O F C A LI FO R N I A L E G A L D E S C R I P T I O N : A D D R E S S : 2 7 2 6 S T R A W B E R R Y L A N E , S A N T A A N A C A 9 2 7 06 TI TLE: N EW D ETA C H ED A D U S A N TA A N A , C A 9 2 7 06 2 7 2 6 S T R A W B E R R Y L A N E , U N I T 2 N EW D ETA C H ED A C C ES S O R Y D W ELLI N G U N I T (A D U ) ELEC TR IC A L M EC H A N IC A L P LA N T Y P E O F O C C U P A N C Y : R -3 /U T Y P E O F C O N S T R U C T I O N : V B G E N E R A L S T R U C T U R E N O T E SS N 1 S - 1 F O U N D A T I O N F R A M I N G P L A N S S D 1 S T R U C T U R A L D E T A I L S S T R U C T U R A L D E T A I L SS D 2 T i t le S h eet T-1 .1 T I T L E S H E E TT - 1 .1 D ES C R IP TIO N D A TE S C A LE D RA W N JO B S H E E T D E S IG N T - 1 . 2 T - 1 . 3 A -0.1 A -1 .1 A -2 .1 A -3 .1 A -4 .1 EX TER I O R ELEV A TI O N & B U I LD I N G S EC TI O N S A -5 .1 A -6 .1 A R C H I T E C T U R A L W A L L R O O F F I N I S H D E T A I L S T - 2 4 . 2 T - 2 4 . 1 E N E R G Y C A L C U L A T I O N S S H E E T E N E R G Y C A L C U L A T I O N S S H E E T 2 . D E M O /R E M O V E T H R E E (E ) S T O R A G E S H E D S (4 8 2 S .F.) A N D O N E (E ) O P E N P A T I O (2 6 5 S .F.). 1 . C O N S T R U C T 9 9 8 S .F. N E W 1 -S T O R Y A C C E S S O R Y D W E L L I N G U N I T , 8 6 S .F. FR O N T P O R C H , & 1 4 0 S .F. O P E N P A T I O . A D D R E S S : S A N T A A N A , C A 9 2 7 0 6 2 7 2 6 S T R A W B E R R Y L A N E , U N I T 2 N E W D E T A C H E D A . D . U . S A N T A A N A , C A 9 2 7 0 6 2 7 2 6 S T R A W B E R R Y L A N E P R O J E C T : 2 P A R K & R EC . D EV ELO P M EN T C A LC U LA TI O N : 1 ,2 06 S FEX I S TI N G LI V I N G A R EA P R O P O S E FL . L I V I N G A R E A 9 9 8 S F (S F D ) (E) M A I N R ES I D EN C E (A D U ) A C C ES S O R Y D W ELLI N G U N I T A D U /S FD R A TI O 3 T I T L E S H E E T N O T E S : 9 8 8 S F / 1 ,2 06 S F = 1 :1 .2 T H E E X I S T I N G R E S I D E N C E . S A FE T Y S T A FF A R E N O T R E S P O N S I B L E FO R T H E A C C U R A C Y O F T H E G I V E N " S FR S F" O F R ES P O N S I B LE FO R TH E G I V EN " S FR S F" O F TH E EX I S TI N G P R I M A R Y R ES I D EN C E; B U I LD I N G T H E A D U S F / S FD S F R A T I O N I S FO R P A R K & R E C FE E P U R P O S E O N L Y . T H E A P P L I C A N T I S FEM A FLO O D Z O N E V ER I FI C A TI O N M A N A G EM EN T A G EN C Y (FEM A ) FLO O D Z O N E A P P LI C A N T TO V ER I FY I F P R O JEC T I S LO C A TED W I TH I N A FED ER A L EM ER G EN C Y FO R R EV I EW A N D A P P R O V A L P R I O R TO B U I LD I N G P ER M I T I S S U A N C E P R O V I D E A N ELEV A TI O N C ER TI FI C A TI O N W I TH S U P P O R TI N G D O C U M EN TS TO TH E C I TY P R O JEC T I S LO C A TED I N FLO O D I N S U R A N C E R A TE M A P (FI R M ) Z O N E A O R A E. P LEA S E P R O JE C T I S N O T L O C A T E D I N FL O O D I N S U R A N C E R A T E M A P (FI R M ) Z O N E X X D E FE R R E D S U B M I T T A L S : S O LA R P A N EL M I N I M U M S I Z E S H O U LD B E 2 .31 K W 5 4 5 2 /2 1 /2 02 5 Bldg #101121201-02 APPROVALS: PLNG - C. Santana BLDG - CSG POLICE - B. Martin PUBLIC WORKS - Y. Soto 2726 W Strawberry Ln & Unit# 23/17/2025 ENAL YRREBWARTS 8'-0" 6'-0" 20'-0" 30'-0" 53'-9" 28'-8" 5'-0" OF SHEETS AS SHOWN REVISIONS BY m inhvantran10@ yahoo.com FO UNTAIN VALLEY CA 92708 18891 SAN CARLO S STREET M INH V. TRAN No. Exp. CIVIL RE G ISTERED PROFESSIONAL ENG INE E R STATE OF CALIFORNIA MINH V. TRAN 65250 9-30-25 LAWN LEGEND: CONCRETE SCALE: 1/8 " = 1'- 0" SITE PLAN NORTH 1 1 PROPERTY LINE 178.72' PROPERTY LINE 137.35' PRO PERTY LINE 125.00' CL 1 PL PL PL SITE PLAN SPECIFICATION 1 2 3 4 5 6 7 PROTECT IN PLACE (E) CONCRETE BLOCK WALL PROTECT IN PLACE (E) WATER HEATER 8 PROTECT IN PLACE (E) CONDESING UNIT 9 PROTECT IN PLACE (E) WATER METER 10 PROTECT IN PLACE (E) POWER POLE PROTECT IN PLACE (E) 200 AMP ELECTRICAL METER PROTECT IN PLACE (E) 1-1/4" GAS METER 2 2 PROTECT IN PLACE (E) 6 FEET HEIGHT WOOD SIDE GATES 1 9 4 5 6 (E) WATER METER (N) WATER METER (1" MINIMUM) AWAY FROM DRIVEWAY APPROACH PER CITY STD. 3 FEET MIN. 7 8 10 DECIDED BY SCE COMPANY & PANEL EXACT LOCATION TO BE PROPOSED 200 AMP ELECTRIC METER BY THE GAS COMPANY LOCATION TO BE VERIFIED PROPOSE GAS METER 1,206 S.F EXISTING RESIDENCE 1 STORY NOT A PART SITE PLAN NOTES: SWIMMING POOL (E) FISH TANK (E) (N) 1 STORY ADU SETBACK ADU SETBACK ADU SETBACK ADU EASEMENT UTILITY SETBACK REAR YARD 18'-0" 2% MIN 4 IN SEWER LINE 11 13 11 12 13 13 PROTECTING IN PLACE (E) LANDSCAPE AREA 12 11 LOT COVERAGE FLOOR AREA ACCESSORY DWELLING UNIT ACCESSORY DWELLING UNIT 1,206 SF (E) MAIN RESIDENCE 1,206 SFEXISTING LIVING AREA (E) MAIN RESIDENCE TOTAL FLOOR AREA 86 SF PROPOSE FL. LIVING AREA EXISTING FLOOR AREA EXISTING PORCH AREA 88 SF 230 SFEXISTING ENCLOSED PATIO 10. FOR SITE DRAINAGE INFORMATION SEE GRADING AND DRAINAGE PLANS, 9. FENCES, GATES, AND FIRE SPRINKLERS ARE TO BE INSTALLED WITH SEPARATE PERMITS, BUILDING, AND DEMOLITION OF EXISTING BUILDING. 8. A SEPARATE PERMIT IS REQUIRED FOR SWIMMING POOLS, SPA, RETAINING WALL, ACCESSORY 7. RESIDENTIAL FIRE SPINKLERS ARE ALL NEW CONTRUCTION. 6. ALL UTITLITY SERVICES, INCLUDING TELEPHONE AND ELECTRIC POWER, SHALL BE UNDERGROUND. 5. A SEPARATE PERMIT IS REQUIRED TO PERFORMED ALL WORK WITHIN STREET RIGHT OF WAY. DRIVEWAY APRONS AS MAY BE REQUIRED BY THE CITY ENGINEER. 4. REPLACE ALL BROKEN, CRACKED OR UPHEAVED CURB, CURB & GUTTER, SIDEWALK AND 3. DO NOT BLOCK NATURAL DRAINAGE COURSES FROM ADJACENT PROPERTIES. 2. LOT DRAINAGE SHALL BE CONDUCTED TO THE STREET OR AS SHOWN ON THE PLANS. 1. ALL LANDSCAPING AREAS, INCLUDING THE PARKWAY SHALL BE AUTOMATICALLY IRRIGATED. (1- STORY) SINGLE FAMILY RESIDENCE NEIGHBOR BUILDING (E) (2- STORY) SINGLE FAMILY RESIDENCE NEIGHBOR BUILDING (E) 13 13 13 PROPOSE LIVING AREA 140 SF TOTAL COVERAGE 1,524 SF 1,224 SF GRAND TOTAL COVERAGE (1,524+1,224) = 2,748 SF 11,646 SF 2,748 / 11,646 = 23.6% < 35% ALLOWABLE OKLOT COVERAGE LOT SIZE = 2022 S.F. OPEN SPACE PCC DRIVEWAY (E) (N) HEAT PUMP MINI SPLIT FOR THE ADU 3 11 11 11 11 12 OPEN PATIO = 140 S.F OPEN PORCH = 86 S.F FLR LV. AREA = 998 S.F PROPOSE OPEN PATIO 998 SF PROPOSE PORCH AREA 998 SF APPROACH (E) DRIVEWAY PATIO ENCLOSED (E) PO RCH (E) 13 13 13 11 13 CONCRETE WALKWAY PL (N) LANDSCAPE AREA TOTAL FLOOR AREA PROPOSE FL. LIVING AREA 998 SF PRIVATE/COMMON SPACE CALCULATIONS 543 455 PRIVATE AREA COMMON AREA PRIVATE/COMMON RATIO 455/998 : 543/988= 46 : 54 3 1 2 BOTANICAL NAME COMMON NAME TYPE SIZE SHRUB ITEM NO.SYMBOL QUANTITY SHRUBFRENCH LAVENDER 2' X 2' WATER NEED FROM WULCOLS LAVANDULA DENTATA LOW1 GAL 5 HEIGHT X SPREAD MATURE SIZE CALLISTEMON "LITTLE JOHN" BOTLEBRUSH LITTLE JOHN DWARF TALL FISCUE FLATMARTHON II LAWN SOD PLANTING LEGEND YES DROUGHT TOLERANT NATIVE AND/OR CALIFORNIA EXISTING LANDSCAPING TO BE PROTECTED IN PLACE 1 3 2 (N) CONCRETE WALKWAY (N) CONCRETE WALKWAY (N) CONCRETE WALKWAY 18" LATERAL SPACING DRIP EMITTER SPACING 18" O.C, IRRIGATION LEGEND SYMBOL MANUFACTURE MODEL NO.DESCRIPTION PSI RAD.GPM 30RAINBIRDSPRAY NOZZLESHE-VAN-10 F, H, T, Q 30RAINBIRDSPRAY NOZZLESHE-VAN-12 F, H, T, Q 12 10 2.37, 1.18, 0.79, 0.59 1.78, 0.89, 0.60, 0.45 11 12/4/2024 (N) HEAT PUMP TANK WATER HEATER FOR THE ADU A-0.1 Site Plan DESCRIPTION DESIG NER DATE JOB SHEET SCALE DRAWN (1,206 + 988) = 2,204 SF UNPERMITTED STRUCTURE DEMOLITION 112 S.F. (E) STORAGE SHED UNPERMITTED STRUCTURE DEMOLITION 192 S.F. (E) STORAGE SHED UNPERMITTED STRUCTURE DEMOLITION 178 S.F. (E) STORAGE SHED UNPERMITTED STRUCTURE DEMOLITION 265 S.F. (E) OPEN PATIO 1 ADDRESS: SANTA ANA, CA 92706 2726 STRAW BERRY LANE, UNIT 2 NEW DETACHED ADU SANTA ANA, CA 92706 2726 STRAW BERRY LANE PRO JECT: 2 140 SF PATIO COVER 86 SF PORCH COVER 3 3 3 WM MINI SPLIT HP MG W/H MG W /H 2726 W Strawberry Ln & Unit# 23/17/2025 1'-0" 1'-0" 1'-0" AS SHOWN DESIG N DATE SCALE DRAWN JOB SHEET OF SHEETS m inhvantran10@ yahoo.com 714-726-5175 FO UNTAIN VALLEY, CA 92708 18891 SAN CARLO S ST. M INH V. TRAN No. Exp. CIVIL RE G ISTERED PROFESSIONAL ENG INE E R STATE OF CALIFORNIA MINH V. TRAN 65250 9-30-25 SCALE: 1/4 " = 1'- 0" BEDROOM 1 (E) BEDROOM 3 (E) BEDROOM 2 (E) LIVING ROOM (E) DINING ROOM (E) KICHEN (E) BATH (E) CLOSET (E) CLOSET (E) 8' CEILING 8' CEILING 8' CEILING 8' CEILING8' CEILING 8' CEILING PORCH (E) NORTH PATIO ENCLOSED (E) W/H WASHER DRYER 1 2 4 3 1 2 3 4 EXISTING HOUSE FLOOR PLAN SPECIFICATION PROTECT IN PLACE EXISTING WATER HEATER PROTECT IN PLACE EXISTING WASHER AND DRYER PROTECT IN PLACE EXISTING 200 AMP ELECTRICAL METER PROTECT IN PLACE EXISTING CONDENSING UNIT 4:12 4:12 4:12 4:12 EXISTING FLOOR PLAN - MAIN HOUSE (NO CHANGE) 9/26/2024 DESCRIPTION House Plan - Main Existing Floor A-1.1 REVISIONS BY 1 ADDRESS: SANTA ANA, CA 92706 2726 STRAW BERRY LANE, UNIT 2 NEW DETACHED A.D.U SANTA ANA, CA 92706 2726 STRAW BERRY LANE PROJECT: 2 2 REF WASHER DRYER 2726 W Strawberry Ln & Unit# 23/17/2025 7'-6"3'-6"5'-6"8'-0"16'-3" 3'-0"5'-6"13'-6" 10'-9" 3'-6" 6'-9" 3'-6" AS SHOWN REVISIONS BY DESIGN DATE SCALE DRAWN JOB SHEET OF SHEETS m inhvantran10@ yahoo.com 714-726-5175 FO UNTAIN VALLEY, CA 92708 18891 SAN CARLO S ST. M INH V. TRAN No. Exp. CIVIL RE G ISTERED PROFESSIONAL ENG INEER STATE OF CALIFORNIA MINH V. TRAN 65250 9-30-25 CLEAN OUT S WP S 3 B AFCI 30"x30" ATTIC ACCESS WALL SWITCH, SINGLE POLE 3-WAY SWITCH FLUORESCENT LIGHT EXHAUSTED FAN, 50 CFM MIN. SENSOR LIGHT A/C DISCONNECT SWITCH GARBAGE DISPOSAL CEILING LIGHT WALL LIGHT HANGING LIGHT (METAL HALIDE LAMP) DOOR BELL HOSE BIBB SYMBOL DESCRIPTION G ELECTRICAL RECEPTACLE WITH TAMPER RESISTANT AND HALLWAY ROOM, DINING ROOM, LIVING ROOM, CLOSET AND TAMPER RESITANTIN ALL BEDROOM, FAMILY RECEPTACLE WITH ARC FAULT CIRCUIT INTERUPTION GFCI RECEPTACLE WITH TAMPER RESITANT MONOXIDE DETECTOR HARD WIRE W/ BATTERY BACK-UP SMOKE/CARBON SUPPLY AIR REGISTER GASKET OR CAULKED BETWEEN HOUSING & CEILING COVER (IC); AIR TIGHT (AT) AND SEALED WITH A APPROVED FOR ZERO CLEARANCE INSULATION RECESS LIGHT (METAL HALIDE LAMP) SHALL BE LIGHT WITH REMOTE CONTROL AUTOMATIC GARAGE DOOR OPENER AND RESITANT GFCI WATER-PROOF RECEPTACLE W/ TAMPER S DIMMER SWITCH DS 1 233 1 1 18'9" X 11'9" LIVING ROOM 18'3" X 12'0" KITCHEN 13'0" X 5'0" 7.75" M AX BEDROOM 2 BEDROOM 1 BEDROOM 3 7.75" M AX 7.75" MAX 7.75" MAX 10'0" X 9'9"10'0" X 9'9" 10'0" X 9'9" BATH 2 BATH 1 5'X9'9"5'X9'9" W.I.C. 1 2 2 3 3 4 4 4 31 5 6 4 8 9 31 5 6 4 8 9 WINDOW EGRESS WINDOW EGRESS TEMPERED TEMPERED 16 A-6 16 A-6 18 A-6 10' CEILING10' CEILING 10' CEILING CLG DO W N CLG DO W N 18 A-6 19 A-6 10' CEILING HALL NORTH SCALE: 1/4 " = 1'- 0" 15'3" +/- VAULTED CEILING 15'3" +/- VAULTED CEILING WINDOW EGRESS 2 13'0" X 5'0" 10'-9"8'-0" 3'-3" 5 PROPOSED FLOOR PLAN - ADU TOTAL FLOOR AREA PROPOSE FL. LIVING AREA 998 SF PRIVATE/COMMON SPACE CALCULATIONS 543 455 PRIVATE/COMMON RATIO 455/998 : 543/988= 46 : 54 PRIVATE COMMON PORCH FRONT 455 S.F. AREA COMMON 543 S.F. AREA PRIVATE 1 2/19/2025 PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE. THE RACEWAY TERMINATION LOCATION SHALL BE FUTURE ELECTRIC VEHICLE CHARGING AS "EV" CAPABLE. PROTECTION DEVICE SPACE DESERVED FOR SERVICE PANEL SHALL IDENTIFY THE OVERCURRENT TERMINATE AT A LISTED CABINET IN THE GARAGE. THE DIAMETER, ORIGINATES AT MAIN SERVICE PANEL AND THE RACEWAY SHOULD NOT BE LESS THAN 1-INCH INSIDE CIRCUIT DEDICATED FOR ELECTRIC VEHIVLE CHARGER. PRE-WIRE 40 AMP CIRCUIT 208 / 240 VOLT BRANCH EV ENERGY REQUIREMENT: REQUIRED TO BE INTERGAL (I.E BUILT-IN) II. A HUMIDITY CONTROL MAY BE A SEPERATE COMPONENT TO THE EXHAUST FAN AND IS NOT MANUAL OR AUTOMATIC MEANS OF ADJUSTMENT. RANGE OF LESS OR EQUAL TO 50% TO A MAXMUM OF 80%. A HUMIDITY CONTROL MAY UTILIZE I. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVELY HUMIDITY BE CONTROL BY A HUMIDITY CONTROL. B. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BUILDING. A. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE 9. EXHAUST FAN IN BATHROOMS LIVING ROOM, FAMILY ROOM AND BEDROOM ETC. SHALL BE HIGH EFFICACY AND DIMMING CONTROLLED 8. ALL PERMANTLY INSTALLED LIGHTING IN OTHER ROOMS SUCH AS HALLWAYS, DINNING ROOM, TO BE USED IN CALIFORNIA. SOCKET. ALL LED'S SHOULD BE ON THE LIST OF THE ENERGY COMMISSION APPROVED LIST 7. ALL LED'S SHOULD HAVE GU-24 LINE VOLTAGE SOCKET OR USE IC RATED WITH 4 PIN BASE 6. FOR ALL KITCHEN LIGHTING MUST BE HIGH EFFICACY. 5. ALL BATHROOM OUTLETS SHALL BE GROUND-FAULT CIRCUIT TYPE. RATED FOR INSULATION CONTACT (IC-RATED) AND AIR TIGHT (AT) LISTED. 4. LUMAINARIES THAT ARE RECESSED INTO INSULATED CEILINGS ARE REQUIRED TO BE MOTION SENSOR WITH AN INTERGRAL PHOTO CONTROL AND ASTRONOMICAL TIME-SWITCH CONTROL. 3. ALL OUTDOOR LIGHTING ATTACHED TO THE BUILDING SHALL BE HIGH EFFICACY AND CONTROLED BY DIMMERS OR MANUAL SWITCH ON AUTOMATIC VACANCY SENSOR OFF. 2. ALL ROOMS (EXCEPT BATHROOMS GARAGE, AND UTILITY ROOMS) ARE TO BE ELECTRIC AND CONTROLLED BY A VACANCY SENSOR. 1. BATHROOM, GARAGE, LAUNDRY, UTILITY AND CLOSET LUMINARIES SHALL HAVE HIGH EFFICACY FLOOR PLAN SPECIFICATION FLUORESCENT LIGHT (TYP.). MEDICINE CABINET (TYP.). MIRROR (TYP.). 1 2 3 MIN. 22" WIDE TEMPERED GLASS DOOR FOR SHOWER (TYP.) 6 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 ALL BATHROOMS FLOORING SHALL BE LAID OVER 15 LB. FELT (TYP.) 30" DIA. MIN CLEARANCE SPACE FOR SHOWER (TYP). CABINET ABOVE (TYP.). GARBAGE DISPOSAL. REFRIGERATOR SPACE. CEILING LIGHT WELL WITH FLORESCENT LIGHTS. DISWASHER, OVEN, OR MICROWAVE SPACES. AUTOMATIC GARAGE DOOR OPENER WITH REMOTE CONTROL AND LIGHT FIXTURE DABMAR LIGHTING FIXTURE (GM-135). RETURN AIR GRILL FOR FIRST FLOOR A/C SYSTEM. FRONT DOOR TO BE RECESSED 4" DEEP.22 " SOLID WOOD CORE OR 20 MIN. RATING DOOR WITH SOLID JAMB. DOOR TO8 31 STANDARDS 119(D). AND WIRING TO PANEL. EXTERIOR LIGHT FIXTURE WITH SENSOR ( PER 2019 ENERGY EFFICIENCY ENCOMPASS 30 INCH (762 MM) DIAMETER CIRCLE. RECEPTOR SHALL BE NOT LESS THAN 1024 SW IN OF FLOOR AREA, AND BE LABELED CATEGORY ii. SWING DOOR OUTWARD. NET AREA OF SHOWER SHALL BE MOISTURE RESISTANT. GLASS ENCLOSURE DOORS AND PANELS MUST EQUAL TO 72" ABOVE DRAIN. MATERIAL OTHER THAN STRUCTURAL ELEMENTS WALL COVERINGS IN SHOWERS AND TUBS TO BE CEMENT PLASTER, TILE OR BE TIGHT FITTING WITH WEATHER STRIPPING AND SELF-CLOSING AND SELF-LATCHING. ARE MADE OF BRASS AND W/O SLIP JOINTS (TYP.) 12" MIN ACCESS PANEL EXCEPT WHERE CONCEALED FIXTURE CONNECTION RESISTANT & LABELLED SAFETY GLAZING (TYP.). WITHIN 5' OF DRAIN OF SHOWER OR BATHROOM FLOOR TO BE SHATTER PROVIDE 6'-0" HT. NON-ABSORBENT WALLS ADJACENT TO SHOWER. WINDOWS SHOWER ENCLOSURE WITH APPROVED SHATTER RESISTANT MATERIALS AND 4 16'-0 " X 8'-0" GARAGE DOOR. EQUIPPED WITH LASER BEAM SAFETY RELEASE. 32 33 34 WASHER AND DRYER WIH TWO SEPARATE 20 AMP CIRCUITS. A/C DISCONNECT SWITCH. HOSE BIBB WITH NON-REMOVABLE BACKFLOW DEVICE. 23 24 25 26 27 28 29 CLOSET DOOR. TIGHT FITTING, SELF-LATCHING AND SELF-CLOSING. SOLID WOOD CORE OR 1-HR FIRE RATED ACCESS COVER, COVER TO BE 30" X 30" ATTIC ACCESS WITH 30" CLEAR HEADROOM AND MIN. 1-3/8" THICK USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE. IN SHOWERS OR TUB-SHOWERS, MAX TEMP. OF 120 F TO BE PROVIDED BY THE 30 31 DRYER VENT TO OUTSIDE AIR WITH BACK DRAFT DAMPER. PROVIDE 4" DIA. SMOOTH GALV. RANGE OR 250 CFM OR 80% CE FOR NATURAL GAS RANGE. HOOD OVER ELECTRIC RANGE SHALL BE 110 CFM OR 50% CE FOR ELECTRIC UNPROTECTED COMBUSTIBLE MATERIAL OR 24" TO METAL VENTILATION HOOD. HOOD VENT TO OUTSIDE AIR. PROVIDE 30" CLEARANCE ABOVE RANGE TO 35 ALL WATER CLOSETS SHOULD HAVE A MINIMUM 30" CLEAR WIDTH AND 24" CLEAR IN FRONT. 36 LAUNDRY ROOM DOOR SHALL BE LOUVERED FOR COMBUSTION AIR. 30" X 30" ATTIC ACCESS WITH 30" CLEAR HEADROOM. 200 AMP ELECTRIC PANEL EXACT LOCATION TO BE APPROVED BY EDISON PLANNER. HEAT PUMP MINI-SPLIT. "PANASONIC" WHISPER WARM FV-11VH2 - CEILING MT'D EXHAUST FAN ---110 CFM. IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE: (CENERGYC 150.0(N)(1)) HEAT PUMP WATER HEATER TANK. ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED 27 DESCRIPTION Floor Plan A-2.1 SANTA ANA, CA 92706 2726 STRAW BERRY LANE, UNIT 2 NEW DETACHED A.D.U SANTA ANA, CA 92706 2726 STRAW BERRY LANE ADDRESS: PROJECT: 4 2 PATIO COVER 3 A-4.1 B A-4.1 B A-4.1 A A-4.1 A 4 4 4 4 REF. 4' X 6' ISLAND WASHER DRYER W/H 2726 W Strawberry Ln & Unit# 23/17/2025 AS SHOWN REVISIONS BY DESIG N DATE SCALE DRAWN JOB SHEET OF SHEETS m inhvantran10@ yahoo.com 714-726-5175 FO UNTAIN VALLEY, CA 92708 18891 SAN CARLO S ST. M INH V. TRAN No. Exp. CIVIL RE G ISTERED PROFESSIONAL ENG INE E R STATE OF CALIFORNIA MINH V. TRAN 65250 9-30-25 ENERGY REQUIREMENT: REQUIRED TO BE INTERGAL (I.E BUILT-IN) II. A HUMIDITY CONTROL MAY BE A SEPERATE COMPONENT TO THE EXHAUST FAN AND IS NOT MANUAL OR AUTOMATIC MEANS OF ADJUSTMENT. RANGE OF LESS OR EQUAL TO 50% TO A MAXMUM OF 80%. A HUMIDITY CONTROL MAY UTILIZE I. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVELY HUMIDITY BE CONTROL BY A HUMIDITY CONTROL. B. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BUILDING. A. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE 9. EXHAUST FAN IN BATHROOMS LIVING ROOM, FAMILY ROOM AND BEDROOM ETC. SHALL BE HIGH EFFICACY AND DIMMING CONTROLLED 8. ALL PERMANTLY INSTALLED LIGHTING IN OTHER ROOMS SUCH AS HALLWAYS, DINNING ROOM, TO BE USED IN CALIFORNIA. SOCKET. ALL LED'S SHOULD BE ON THE LIST OF THE ENERGY COMMISSION APPROVED LIST 7. ALL LED'S SHOULD HAVE GU-24 LINE VOLTAGE SOCKET OR USE IC RATED WITH 4 PIN BASE 6. FOR ALL KITCHEN LIGHTING MUST BE HIGH EFFICACY. 5. ALL BATHROOM OUTLETS SHALL BE GROUND-FAULT CIRCUIT TYPE. RATED FOR INSULATION CONTACT (IC-RATED) AND AIR TIGHT (AT) LISTED. 4. LUMAINARIES THAT ARE RECESSED INTO INSULATED CEILINGS ARE REQUIRED TO BE MOTION SENSOR WITH AN INTERGRAL PHOTO CONTROL AND ASTRONOMICAL TIME-SWITCH CONTROL. 3. ALL OUTDOOR LIGHTING ATTACHED TO THE BUILDING SHALL BE HIGH EFFICACY AND CONTROLED BY DIMMERS OR MANUAL SWITCH ON AUTOMATIC VACANCY SENSOR OFF. 2. ALL ROOMS (EXCEPT BATHROOMS GARAGE, AND UTILITY ROOMS) ARE TO BE ELECTRIC AND CONTROLLED BY A VACANCY SENSOR. 1. BATHROOM, GARAGE, LAUNDRY, UTILITY AND CLOSET LUMINARIES SHALL HAVE HIGH EFFICACY 18'9" X 11'9" LIVING ROOM 18'3" X 12'0" KITCHEN 13'0" X 5'0" 7.75" M AX BEDROOM 2 BEDROOM 1 BEDROOM 3 7.75" M AX 7.75" MAX 10'0" X 9'9"10'0" X 9'9" 10'0" X 9'9" W.I.C. 31 5 6 4 8 9 31 5 6 4 8 9 11 12 24 13 FLOOR PLAN SPECIFICATION FLUORESCENT LIGHT (TYP.). MEDICINE CABINET (TYP.). MIRROR (TYP.). 1 2 3 MIN. 22" WIDE TEMPERED GLASS DOOR FOR SHOWER (TYP.) 6 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 ALL BATHROOMS FLOORING SHALL BE LAID OVER 15 LB. FELT (TYP.) 30" DIA. MIN CLEARANCE SPACE FOR SHOWER (TYP). CABINET ABOVE (TYP.). GARBAGE DISPOSAL. REFRIGERATOR SPACE. CEILING LIGHT WELL WITH FLORESCENT LIGHTS. DISWASHER, OVEN, OR MICROWAVE SPACES. AUTOMATIC GARAGE DOOR OPENER WITH REMOTE CONTROL AND LIGHT FIXTURE DABMAR LIGHTING FIXTURE (GM-135). RETURN AIR GRILL FOR FIRST FLOOR A/C SYSTEM. FRONT DOOR TO BE RECESSED 4" DEEP.22 " SOLID WOOD CORE OR 20 MIN. RATING DOOR WITH SOLID JAMB. DOOR TO8 31 STANDARDS 119(D). AND WIRING TO PANEL. EXTERIOR LIGHT FIXTURE WITH SENSOR ( PER 2019 ENERGY EFFICIENCY ENCOMPASS 30 INCH (762 MM) DIAMETER CIRCLE. RECEPTOR SHALL BE NOT LESS THAN 1024 SW IN OF FLOOR AREA, AND BE LABELED CATEGORY ii. SWING DOOR OUTWARD. NET AREA OF SHOWER SHALL BE MOISTURE RESISTANT. GLASS ENCLOSURE DOORS AND PANELS MUST EQUAL TO 72" ABOVE DRAIN. MATERIAL OTHER THAN STRUCTURAL ELEMENTS WALL COVERINGS IN SHOWERS AND TUBS TO BE CEMENT PLASTER, TILE OR BE TIGHT FITTING WITH WEATHER STRIPPING AND SELF-CLOSING AND SELF-LATCHING. ARE MADE OF BRASS AND W/O SLIP JOINTS (TYP.) 12" MIN ACCESS PANEL EXCEPT WHERE CONCEALED FIXTURE CONNECTION RESISTANT & LABELLED SAFETY GLAZING (TYP.). WITHIN 5' OF DRAIN OF SHOWER OR BATHROOM FLOOR TO BE SHATTER PROVIDE 6'-0" HT. NON-ABSORBENT WALLS ADJACENT TO SHOWER. WINDOWS SHOWER ENCLOSURE WITH APPROVED SHATTER RESISTANT MATERIALS AND 4 16'-0 " X 8'-0" GARAGE DOOR. EQUIPPED WITH LASER BEAM SAFETY RELEASE. 32 33 34 WASHER AND DRYER WIH TWO SEPARATE 20 AMP CIRCUITS. A/C DISCONNECT SWITCH. HOSE BIBB WITH NON-REMOVABLE BACKFLOW DEVICE. 23 24 25 26 27 28 29 CLOSET DOOR. TIGHT FITTING, SELF-LATCHING AND SELF-CLOSING. SOLID WOOD CORE OR 1-HR FIRE RATED ACCESS COVER, COVER TO BE 30" X 30" ATTIC ACCESS WITH 30" CLEAR HEADROOM AND MIN. 1-3/8" THICK USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE. IN SHOWERS OR TUB-SHOWERS, MAX TEMP. OF 120 F TO BE PROVIDED BY THE 30 31 DRYER VENT TO OUTSIDE AIR WITH BACK DRAFT DAMPER. PROVIDE 4" DIA. SMOOTH GALV. RANGE OR 250 CFM OR 80% CE FOR NATURAL GAS RANGE. HOOD OVER ELECTRIC RANGE SHALL BE 110 CFM OR 50% CE FOR ELECTRIC UNPROTECTED COMBUSTIBLE MATERIAL OR 24" TO METAL VENTILATION HOOD. HOOD VENT TO OUTSIDE AIR. PROVIDE 30" CLEARANCE ABOVE RANGE TO 29 29 16 A-6 16 A-6 16 A-6 18 A-6 10' CEILING10' CEILING 10' CEILING CLG DO W N CLG DO W N 22 18 A-6 19 A-6 10' CEILING HALL NORTH SCALE: 1/4 " = 1'- 0" 10 15'3" +/- VAULTED CEILING 15'3" +/- VAULTED CEILING 10 13'0" X 5'0" 3'-3" 27 MECHANICAL/PLUMBING PLAN PORCH FRONT 12/4/2024 NORTH SCALE: 1/4 " = 1'- 0" ELECTRICAL PLAN CLEAN OUT S WP S 3 B AFCI 30"x30" ATTIC ACCESS WALL SWITCH, SINGLE POLE 3-WAY SWITCH FLUORESCENT LIGHT EXHAUSTED FAN, 50 CFM MIN. SENSOR LIGHT A/C DISCONNECT SWITCH GARBAGE DISPOSAL CEILING LIGHT WALL LIGHT HANGING LIGHT (METAL HALIDE LAMP) DOOR BELL HOSE BIBB SYMBOL DESCRIPTION G ELECTRICAL RECEPTACLE WITH TAMPER RESISTANT AND HALLWAY ROOM, DINING ROOM, LIVING ROOM, CLOSET AND TAMPER RESITANTIN ALL BEDROOM, FAMILY RECEPTACLE WITH ARC FAULT CIRCUIT INTERUPTION GFCI RECEPTACLE WITH TAMPER RESITANT MONOXIDE DETECTOR HARD WIRE W/ BATTERY BACK-UP SMOKE/CARBON SUPPLY AIR REGISTER GASKET OR CAULKED BETWEEN HOUSING & CEILING COVER (IC); AIR TIGHT (AT) AND SEALED WITH A APPROVED FOR ZERO CLEARANCE INSULATION RECESS LIGHT (METAL HALIDE LAMP) SHALL BE LIGHT WITH REMOTE CONTROL AUTOMATIC GARAGE DOOR OPENER AND RESITANT GFCI WATER-PROOF RECEPTACLE W/ TAMPER S DIMMER SWITCH DS PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE. THE RACEWAY TERMINATION LOCATION SHALL BE FUTURE ELECTRIC VEHICLE CHARGING AS "EV" CAPABLE. PROTECTION DEVICE SPACE DESERVED FOR SERVICE PANEL SHALL IDENTIFY THE OVERCURRENT TERMINATE AT A LISTED CABINET IN THE GARAGE. THE DIAMETER, ORIGINATES AT MAIN SERVICE PANEL AND THE RACEWAY SHOULD NOT BE LESS THAN 1-INCH INSIDE CIRCUIT DEDICATED FOR ELECTRIC VEHIVLE CHARGER. PRE-WIRE 40 AMP CIRCUIT 208 / 240 VOLT BRANCH EV 32 23 A-6 21 A-6 22 A-6 35 ALL WATER CLOSETS SHOULD HAVE A MINIMUM 30" CLEAR WIDTH AND 24" CLEAR IN FRONT. ABOVE GROUND A CONSUMER INSTANTANEOUS GAS WITH EFFICIENCY 0.96 TO BE INSTALLED 48" MIN. 35 35 25 36 LAUNDRY ROOM DOOR SHALL BE LOUVERED FOR COMBUSTION AIR. 36 23 26 7.75" MAX 30" X 30" ATTIC ACCESS WITH 30" CLEAR HEADROOM. 30 200 AMP ELECTRIC PANEL EXACT LOCATION TO BE APPROVED BY EDISON PLANNER. HEAT PUMP MINI-SPLIT. "PANASONIC" WHISPER WARM FV-11VH2 - CEILING MT'D EXHAUST FAN ---110 CFM. DESCRIPTION Plans Electrical Plumbing/ Mechanical/ A-3.1 SANTA ANA, CA 92706 2726 STRAW BERRY LANE, UNIT 2 NEW DETACHED A.D.U SANTA ANA, CA 92706 2726 STRAW BERRY LANE ADDRESS: PROJECT: 1 3 2 3 3 3 PATIO COVER 3 1"O CW 34 34 1"O HW 1"O CW 1"O HW 1"O HW 1"O CW 1"O CW 1"O HW 1/2"O HW 1/2"O CW 3/4"O HW 3/4"O CW 3/4"O HW 3/4"O CW 3/4"O HW 3/4"O CW 3 REF. 4' X 6' ISLAND WASHER DRYER CLIMATE MINI SPLIT HP W/H REF. 4' X 6' ISLAND WASHER DRYER S DSS SDSSDS SDS AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI 240V GFCI AFCI AFCI AFCI AFCI AFCI SDSS S S S SS EV B W/H WP WP WP WP GFCI AFCI 2726 W Strawberry Ln & Unit# 23/17/2025 8'-0" 8'-0" 10'-0"15'-4" 13'-10" 14'-3" 10'-0" 10'-0" 10'-0" 5'-0" 14'-4" 5'-0" 3'-0" 3'-0" 3'-0" AS SHOWN REVISIONS BY SCALE : 1/4" = 1'- 0" (E) C.B.W SETBACK SCALE : 1/4" = 1'- 0" PL (E) C.B.W SETBACK SCALE : 1/4" = 1'- 0" PL SCALE : 1/4" = 1'- 0" (E) C.B.W SETBACK ELEVATION SPECIFICATION 1 2 3 4 5 NEW WINDOW WITH COLOR FINISH TO MATCH THE MAIN HOUSE EXTERIOR STUCCO WITH COLOR FINISH TO MATCH THE MAIN HOUSE 1" X 4" WOOD TRIMBOARD BASE (CEDAR PLANK PAINT) WITH COLOR FINISH TO MATCH MAIN HOUSE 2 X 6 FASCIA BOARD WITH COLOR FINISH TO MATCH THE MAIN HOUSE 1 2 3 4 5 6 6 7 8 DABMAR LIGHT FIXTURE (GM-135) (TYP) 9 FRENCH DOOR (SEE STRUCTURE FOR SIZE TYP) 2 X ROOF RAFTER WITH COLOR FINISH TO MATCH THE MAIN HOUSE 7 8 9 1 2 59 8" F.F. T.P TOP RIDGE TOP RIDGE (E) C.B.W 1 2 6 15'-3" TOP RIDGE TOP RIDGE TOP RIDGE 9 3 1 2 9 3 4 5 5 8" F.F. T.P 8" F.F. T.P 15'-3" TOP RIDGE TOP RIDGE T.P TOP RIDGE 13'-10" PL 14'-3" 13'-10" 15'-3" TOP RIDGE TOP RIDGE 49595 DARK CHARCOAL, BLACK STREAKS CONC. FLAT TILE ROOF OVER 30 LBS. FELT ON ROOF SHEATHING (EAGLE ROOFING PRODUCT CRRC 0918-016), SOLID WOOD DOOR 6 2 A-6 4 6 A-6 TYP 12 A-6 3 A-6 10 7 1 8 SECTION A-A CLOSET 5 9 " = 1'- 0"4 1SCALE: LIVING ROOM BEDROOM 2 BEDROOM 1 LIVING ROOM KITCHEN VAULTED CEILING SECTION B-B " = 1'- 0"4 1SCALE: 1 5 12 A-6 6 A-6 TYP 2 A-6 9 4 12 A-6 T.P TYP 12 4 TYP 12 4 TYP 12 4 ADU - FRONT ELEVATION (NORTH) ADU - REAR ELEVATION (SOUTH) ADU - LEFT ELEVATION (EAST) ADU - RIGHT ELEVATION (WEST) SETBACK PL 2 X ROOF RAFTER (SEE STRUCTURE FOR SIZE TYP) " STUCCO FINISH OVER METAL LATH & FELT (TYP)8 7 2 X CEILING JOIST (SEE STRUCTURE FOR SIZE TYP) 8 7 6 5 4 3 2 1 R-15 INSULATION FOR EXTERIOR WAL (TYP) R-19 INSULATION FOR FLOOR AREA SECTION SPECIFICATION R-30 INSULATION FOR CEILING AREA (TYP) " GYPSUM BOARD FINISH (TYP)8 5INTERIOR PLYWOOD SHEATHING "32 15SHINGLE ROOF OVER 30LBS FELT ON —" 9 R-30 INSULATION BELOW ROOF DECK (TYP) DESCRIPTION DATE SCALE DRAWN JOB SHEET OF SHEETS A-4.1 Sections Building Elevations/ Exterior m inhvantran10@ yahoo.com 714-726-5175 FO UNTAIN VALLEY, CA 92708 18891 SAN CARLO S ST. M INH V. TRAN No. Exp. CIVIL RE G ISTERED PROFESSIONAL ENG INE E R STATE OF CALIFORNIA MINH V. TRAN 65250 9-30-25 DESIG N SANTA ANA, CA 92706 2726 STRAW BERRY LANE, UNIT 2 NEW DETACHED A.D.U SANTA ANA, CA 92706 2726 STRAW BERRY LANE ADDRESS: PRO JECT: 1 2 3 2/8/2025 2726 W Strawberry Ln & Unit# 23/17/2025 1'-6" 1'-6" 1'-6" 1'-6" AS SHOWN DATE SCALE DRAWN JOB SHEET OF SHEETS B B ROOM FLOOR BASE WALL CEILING CO NCRETE CARPET TILE / M ARBLE HARD W O O D W O O D PLASTIC G YP. BD "X" G YP. BD G YP. BD "W P" G YP. BD "X" G YP. BD G YP. BD "W P" CRO W N M O LDING I II III A B a b FOYER LIVING RM DINING RM FAMILY RM KITCHEN BEDROOMS BATHS MASTER BED W.I.C STAIRWAY GARAGE II II II II II II II II II B B FINISH SCHEDULENOTES: * FOR 8' CEILING HEIGHT, USE 4" BASE BOARD * FOR 9' OR 10' CEILING HEIGHT, USE 6" BASE BOARD * FOR CEILING HEIGHT ABOVE 10', USE 8" BASE BOARD * FOR CEILING HEIGHT UP TO 12', USE 6" CROWN MOLDING * FOR CEILING HEIGHT ABOVE 12', USE 8" CROWN MOLDING A A A A A A A A B B A A A A A A A A a a a a 4" BASE BOARD 6" BASE BOARD 8" BASE BOARD FLAT PAINT SEMI GLOSS PAINT 6" CROWN MOLDING 8" CROWN MOLDING NORTH SCALE: 3/8 " = 1'- 0" NOTES: CALCULATION FOR WHOLE HOUSE VENTILATION FOR INDOOR AIR QUALITY (IAQ) C. TYPICAL VENT AREA NOTE: ALL TYPE 1 VENTS SHOULD BE PAINTED SAME COLOR AS ROOF 1. 24" HALF ROUND DORMER LOUVER VENT : 3.14 X 1.002/2 = 1.57 S.F 3. VENT AREA PROVIDED : 4 X 1.57 (TYPE 1) = 6.3 S.F CALCULATION FOR NATURAL LIGHTING AND VENTILATION AREA No. Exp. CIVIL RE G ISTERED PROFESSIONAL ENG INEER STATE OF CALIFORNIA MINH V. TRAN 9-30-25 65250 m inhvantran10@ yahoo.com 714-726-5175 FO UNTAIN VALLEY, CA 92708 18891 SAN CARLO S ST. M INH V. TRAN DESIG NER A.D.U. ROOF PLAN A. ATTIC VENTILATION CALCULATION (ADU) A DOUBLE HUNG SINGLE / B SLIDING C FIXED D FIXED / STACKED L A WINDOW SCHEDULE EVERY SLEEPING ROOM SHALL HAVE AN EGRESS WINDOW HAVE A ALL WINDOWS SHALL BE DUAL GLAZED AND LABELED FINISHED SILL HEIGHT NOT MORE THAN 44" ABOVE FINISHED FLOOR ALL NEW GLAZING SHALL COMPLY WITH STANDARDS OF THE U.S CONSUMER PRODUCT SAFETY COMMISION MANUFACTURES TO SUPPLY CERTIFICATE OF COMPLIANCE TO THE OWNER MATERIALSIZE W INDO W SYM BO L W INDO W TYPE W IDTH HEIG HT VINYL TEM PERED O BSCURE WINDOW TOP OF 1 2 CLEAR PANEL NO GRID FOR ALL WINDOWS 8' - 0" 3 8' - 0"B 5' - 0" B 4' - 0" B 8' - 0" ALL WINDOWS SHOULD RECESS MINIMUM 2 IN U FACTOR: 0.30, SHGC: 0.21 5' - 0" 4' - 0" 4' - 0"3' - 0" A SWINGING FLUSH B SWINGING C SLIDING DOOR TEMP. GLASS DO O R SYM BO L DO O R TYPE W IDTH HEIG HT THICKNESS SO LID HO LLO W KEYLO CK DEADLO CK DO O R VIEW ER PRIVACY LO CK SELF CLO SING TEM PER G LASS W O O D MATERIALHARDWARECORESIZE DOOR SCHEDULE 1 BE DUAL PANELS ALL GLAZED OPENING SHALL 2 3 D 3' - 6"8' - 0""431 RECESS DOOR 4" DEEP B 5' - 0"8' - 0""831 A 2' - 6"8' - 0""831 TIGHT FITTING & SELF CLOSING W WEATHER STRIPPING4 A 2' - 8"8' - 0""831 IRO N 5 2' - 5"A 6' - 8""831 DOOR FRONT D H 6 X 0.58 (TYPE 2) = 3.5 S.F 3. ALL TYPE 1 VENTS SHOULD BE PAINTED SAME COLOR AS ROOF. 4. ATTIC VENTS OPENING SHALL HAVE CORROSION-RESISTANT WITRE MESH OR OTHER APPROVED MATERIALS WITH 1/16 INCH MINIMUM AND 1/4 INCH MAXIMUM OPENING. THE ADU SHALL BE SUBSTANTIALLY THE SAME AS THE MAIN HOUSE. 1. THE DESIGN, PITCH, COLOR, MATERIAL, AND TEXTURE OF THE ROOF EAVE DETAILS OF THE ADU SHALL BE SIMILAR AND COMPATIBLE WITH THE MAIN HOUSE. 2. THE COLOR, MATERIAL, TEXTURE OF ALL BUILDING WALLS, WINDOWS, AND DOORS OF REVISIONS BY (TYP 1 OF 4) LOUVER VENT 24" HALF ROUND DORMER 4:12 4:12 4:12 4:12 1 A-6 4. TOTAL PROVIDED = 9.8 S.F > 6.7 S.F REQUIRED (TYP 1 OF 6) 6" X 14" EAVE VENT REQUIRED : PROVIDED: OK 1. BEDROOM 1 = 10'0" X 9'9" = 97.5 SF LIGHT (8%) = 97.5 SF X 8% = 7.8 SF VENTILATION (4%) = 97.5 X 4% = 3.9 SF LIGHT = WINDOW (5'0" X 5'0")= 25 SF VENTILATION = W 1/2 OPENABLE = 12.5 SF REQUIRED : PROVIDED: OK 2. BEDROOM 2 = 10'0" X 9'9" = 97.5 SF LIGHT (8%) = 97.5 SF X 8% = 7.8 SF VENTILATION (4%) = 97.5 X 4% = 3.9 SF LIGHT = WINDOW (5'0" X 5'0")= 25 SF VENTILATION = W 1/2 OPENABLE = 12.5 SF REQUIRED : PROVIDED: OK 3. BEDROOM 3 = 10'0" X 9'9" = 97.5 SF LIGHT (8%) = 97.5 SF X 8% = 7.8 SF VENTILATION (4%) = 97.5 X 4% = 3.9 SF LIGHT = WINDOW (5'0" X 5'0")= 25 SF VENTILATION = W 1/2 OPENABLE = 12.5 SF 5. SO, OK 65 CFM @ 3/8" S.P > 30.5 CFM "PANASONIC" WHISPER FV-08VQ5 CEILING MT'DEXHAUST FAN 4. WE USE EXHAUST FAN: REQUIRED VENTILATION = 998/100+ (3+1) X 7.5 = 40.0 CFM 3. PER ANSI ASHRAS 62.2 EQUATION 4.1A 2. TOTAL BEDROOM = 3 1. TOTAL AREA : 998 S.F 4:12 4:12 NOTES NOTES NOTES DESCRIPTION Notes Schedules & Roof Plan/ A-5.1 SANTA ANA, CA 92706 2726 STRAW BERRY LANE, UNIT 2 NEW DETACHED ADU SANTA ANA, CA 92706 2726 STRAW BERRY LANE ADDRESS: PRO JECT: 1 2SOLAR READY 4 B. VAULTED CEILINGS VENTILATION CALCULATION (ADU) 1. NO ATTIC AREA TO BE VENTILATED: 448 S.F. 2. 6 X 14 EAVE VENT : NET FREE VENTILATION AREA = 52 SQ. IN. 1. ATTIC AREA TO BE VENTILATED: 550 S.F. 2. VENT AREA REQUIRED: 550 S.F / 150 = 3.70 S.F. 2. VENT AREA REQUIRED: 448 S.F / 150 = 3.0 S.F. 3. ACTUAL RIDGE VENT 2" PER INCH: 17 L.F. X 2"/12"= 2.83 S.F. = 408 SQ. IN. 3 4 2/8/2025 4. NO. OF VENTS PROVIDED = 408 SQ. IN. / 52 SQ. IN. = 7.8 = 8.0 VENTS EACH SIDE 2726 W Strawberry Ln & Unit# 23/17/2025 24" D.C. each side. (LOAD-BEARING) nailed to top and bottom plates at 7" o.c. Stagger joints 1-7/8" long, 0.0915" shank,‚" heads, 7" o.c. Wallboard 2 x 4 wood studs spaced 24" o.c., with 6d coated nails applied parallel with of at right angles to each side of One layer†" type X gypsum wallboard or veneer base INSULATION R-15 (2X6 MIN. FOR PLUMBING WALL) 2 X STUD @ 16" O.C. (SEE STUCTURAL PLAN) PLYWOOD IF OCCURS OVER PLYWOOD) (2-LAYERS GRAD "D" FELT LATH METAL GARAGE EXTERIOR WALL) (5/8" TYPE X GYP. BD. FOR " X GYP. BD.8 5 (SEE STRUCTURAL PLAN) PLYWOOD IF OCCURS FOR BATHROOM) WATER RESISTANT TYPE UNDER STAIR SIDE & USABLE SPACE (TYPE X GYP. BD. FOR GARAGE " X GYP. BD.8 5 PLUMBING WALL) (2X6 MIN FOR 2XSTUD @ 16" O.C. " GYP. BD.8 5 HABITABLE AREA BETWEEN GARAGE & R-15 INSULATION FOR BATHROOM) WATER RESISTANT TYPE UNDER STAIR SIDE & USABLE SPACE (TYPE X GYP. BD. FOR GARAGE " X GYP. BD.8 5 2 x FJ @ 16" O.C. FOR FLOOR COVERING SEE FIN. SCHEDULE " GYPCRETE4 3 T&G PLYWD " CDX32 19 OVERHANG (IF OCCURS) OVER GARAGE OR R-19 INSULATION 2 ND FLOOR HABITABLE AREA BETWEEN GARAGE & R-13 INSULATION ASSEMBLY DESCRIPTION: Gypsum Wallboard, Wood Studs Fire Test: Approx. Weight: 7 psf Thickness: 4-7/8" UL R3501-47, 48, 9-i7-65; Sound Test: NGC 2404, 10-14-70 Design U314 R1319-129.7-22-70 Design U309 Gypsum Wallboard, Wood Studs GA File No. WB 3510 Fire Rating: 1-Hour 4" TYP. 6" M IN. TO WD. BLK'G MET HANGER & NAILED VENT PIPE W/SHT. COMPOUND FLASHING 2 X BLK'G 2 X RAFTER VENT PIPE (TYP.) FLASHING AROUND 24 GA. G.I. ALL AROUND SEALANT 4" TYP. ROOF SHEATHING ROOFING FELT ROOF RAFTER RIDGE A35 @ EA RAFTER FIN. GRADE LATH OVER GRADE "D" FELT " EXT. STUCCO ON METAL8 7 R-15 INSULATION " GYP. BD.8 5 @ EACH A. BOLT 3"X3'X0.229 PLATE WASHER SILL PLATE 2 X P.T. CONC. FOOTING CONC. (SEE STR'L FOR DETAILS) EMBEDDED 7" MIN. INTO " ANCHOR BOLT8 5 2X4 OR 2X6 AS REQUIRED 8" M IN. "8 7 CO NC. 4" ABO VE G RADE. 6" ABO VE FINISH GRADE 8" M IN. 1-3/4" BUILDING PAPER WOOD STUD P.T. 2 X SILL PLATE EXTERIOR PLASTER REINFORCE MESH WEEP SCREED #26 G.I. FOUNDATION 1'-4" & POLE SEE PROVIDE SHELF 4 HOLLOW CORE SLIDING DOOR " GYP. BD.8 5 SOFIT 6'-8" 1-1/2" WOOD FRAMING " PLYWOOD ON8 5 2X WOOD BLKF 2X4 WOOD CONT. INT. GYP. BD. 2X4 WOOD STUD POLE 1-1/2" O 5'-0" TO FIN. FLO O R 6" M IN. THE FLOOR (MIN.) UNOBSTRUCTED TO FLOURESCENT RECESSED 6" 6" 18" " EXT. STUCO FINISH8 7 SERVICE INCONMING UNDERGROUND 2 X STUD @ O.C. ALLOWED INTO GARAGE SIDE WALL, NO FURRED OUT IS ENCLOSED WITHIN 2XSTUD ELECTRICAL SERVICE IS ROMEX CABLE CONDUIT TO PROTECT GALVANIZED METAL " TYPE "X" GYP. BD.8 5 OUTSIDE INSIDE CERAMIC TILE ADHENSIVE WOOD STUDS @16" O.C. SEALANT BATH TUB GYP. BD. " WATER RESISTANT8 5 SEALANT WALL SPACER 1X4 @ 32" O.C. 2X4 STRECHERS " X 3-/12"4 3 " PLYWD4 3 TOP SET " X 1-1/4" ASH4 3 VENEER " PLYWD. W/ASH4 3 " X 1-1/2" ASH4 3 VENEER " PLYWD. W/ASH4 3 " X 1-1/2" ASH4 3 TOP SIMULATED MARBLE ONE PIECE 2'-8" SCRIBE 3-1/2" 4"1'-10" SEE DETAIL "A" NOTE DETAIL "A" TOP VIEW GYPSUM BOARD " TYPE "X"8 5 METAL ANGLE 1"X1"X1/8" 1/3 HEIG HT 1/3 HEIGHT HEIG HT WD. SHIM WD. TRIM GRADE "D" FELT METAL LATH OVER CEM. PLASTER ON 2 X WD. STUD 1 X WD. FRAME .. . . .. .. . .. .. . . . . . .. . . . . . . .. .. . . . . . .. .. . . .. . . .. . . . . . . .. .. . . . . . .. .. . . .. . . .. . . . . . . .. .. . . . . . .. .. . . .. . . .. . . . . . . .. .. . . . . . .. .. . . .. . . .. . . . . . . .. .. . . . . . .. .. . . .. . . .. . . . . . . .. .. . . . . . .. .. . . .. . . .. . . . . . . .. .. . . . . . .. .. . . .. . . .. . . . . . . .. .. . . . . . .. .. . . .. . . .. . . . . . . .. .. . . . . . .. .. . . .. . . .. . . . . . . .. .. . . . . . .. .. . . .. . . .. . . . . . . .. .. . . . . . .. .. . . .. . . .. . . . . . . .. .. . . . . . .. .. . . .. . . .. . . . . . . .. .. . . . . . .. .. . . .. . . . . . .. . . .. . FOR FLOOR COVERING SEE FIN. SCHEDULE 1" MORTAR BED 10X10 W.W.F. 4" CONC. SLAB W/6X6- ANOTHER LAYER OF 2" CLEAN SAND 6-MIL VISQUEEN AND BELOW 2" CLEAN SAND OVER RESIDENTIAL GRADE, MIN. 30 OZ. CARPET " X 24 PCF URETHANE2 1MIN. (SEE STRUCTURAL PLAN) 4" CONC. SLAB W/REINFORCEMENT ANOTHER LAYER OF 2" CLEAN SAND 6-MIL VISQUEEN AND BELOW 2" CLEAN SAND OVER GROUT QUARRY TILE/CERAMIC TILE 1" MORTAR BED (SEE STRUCTURAL PLAN) 4" CONC. SLAB W/REINFORCEMENT ANOTHER LAYER OF 2" CLEAN SAND 6-MIL VISQUEEN AND BELOW 2" CLEAN SAND OVER OR SEE PLAN 7.75" MAX OR SEE PLAN CORE DOOR 1-3/4" SOLID " MAX. THRESHOLD2 1 PROPERTY LINE REBAR IN GROUT FILLED CELLS W/ #4 @32" O.C. VERT. & HORIZ. 6" CONC. BLK. WALL @18" O.C. OMIT 1ST COURSE HEADJOINT 1 #4 T&B EQ EQ FL 2% 9" 12" 18" 24" 6'-0" O R 4'-0" (NO RETAINING SO IL) SCALE N.T.S. SCALE N.T.S. SCREW " X 2-1/2" LAG8 3 3" DIA FLUE PROVIDE SOLID BACK BEHIND WATER HEATER FOR MOUNTING PURPOSE THERMOMETER SECURE TO WALL SHUT-OFF VALVE (TYP) HW TO FIXTURE CW SUPPLY CHECK VALVE (TYP) HEATER WATER TANKLESS UNION (TYP) DRAIN VALVE G GAS SUPPLY 6" LONG DIRT LEG 1/3 HEIG HT EXT SIDING SHINGLE ROOF ELECTRICAL SERVICE DETAIL24 EXTERIOR WALL FOOTING 20 BATH TUB TO WALL 21 BATH ROOM COUNTER 22 23 GARAGE HEADER 19STEP DOWN AT EXTERIOR DOOR 18QUARRY TILE / CERAMIC TILE FLOORING 17CARPET OVER CONC. SLAB ON GRADE HARD WOOD OVER CONC. SLAB ON GRADE 16 11 EXTERIOR WALL 6 7INTERIOR WALL FLOOR / CEILING ASSEMBLY 813 12 BLOCK WALL SECTION 14 HOUSE & GARAGE SEPARATION WALL 9 10VENT PIPE DETAIL15 W.I.C LIGHTING 5 SHELF AND POLE CLOSET 3 2 1RIDGE / HIP DETAIL REVISIONS BY A-3 2 AND 7 SQUARE INCH 1,000 BTU FOR GRAVITY FEED TYPE. 5. AIR SUPPLY OPENING OF 2 SQUARE INCH PER 1,000 BTU FOR BLOWER TYPE 4. LIGHT OVER EQUIPMENT WITH SWITCH AT ACCESS. WITH 30" HEADROOM. 3. A LEVEL UNOBSTRUCTED WORK PLATFORM MIN. 30" IN FRONT OF EQUIPMENT FLOORING FROM ACCESS TO EQUIPMENT/CONTROL PANEL. 2. UNOBSTRUCTED PASSAGE 24" WIDE WITH SOLID CONTIUNOUS 1. ATTIC ACCESS MIN. 30"X30" NOT OVER 20' FROM EQUIPMENT. FURNACE ATTIC 5' M IN. 30" OPENING ACCESS 30"X30" DRAIN TAILPIECE. CONNECT TO LAVATORY CONDENSATE DRAIN LINE DRAIN TAILPIECE. CONNECT TO LAVATORY CONDENSATE DRAIN LINE R-30 INSULATION SWITCH LIGHT ACCESS PANEL SEAL AT THE ATTIC WEATHER STRIP OR ACCESS WAY 24" WIDE SOLID FLOOR OVERFLOW PAN WATERTIGHT LIGHT OVER CONTROLS ELECTRICAL DISCONNECT PROVIDE POSITIVE ATTIC FURNACE INSTALLATION REQUIREMENTS 20' MAX. AIR FURNACE - ATTIC No. Exp. CIVIL RE G ISTERED PROFESSIONAL ENG INE ER STATE OF CALIFORNIA 65250 MINH V. TRAN 9-30-25 DESIG NER m inhvantran10@ yahoo.com 714-726-5175 FO UNTAIN VALLEY, CA 92708 18891 SAN CARLO S ST. M INH V. TRAN 4 NO SCALE 1-HOUR FIRE RATED EAVE RAFTER PLYWD SHEATH'G R-30 INSULATION EAVE VENTS WOOD RAFFLE @ R-13 INSULATION W/ KICKOUT ROOF EDGING SET IN MASTIC 24 GAGI FLASHING Z BAR FLASHING 1-30# FELT OVER 15/32" PLYWD SHEATH'G 1-30# FELT OVER 15/32" SHINGLE ROOF ON EAVE PROJECTION FROM 2 FT. TO 5 FT. FROM PROPERTY LINE FOR OVERHANG SEE ROOF PLAN 2X FASCIA (2-LAYER OVER PLYWOOD) GRADE "D" FELT ON METAL LATH OVER EXTERIOR STUCCO7/8"PROVIDE 2 X FIRE BLOCK " TYPE X GYP. BD.8 5 PLYWD SHEATH'G R-30 INSULATION EAVE VENTS WOOD RAFFLE @ R-13 INSULATION W/ KICKOUT ROOF EDGING SET IN MASTIC 24 GAGI FLASHING Z BAR FLASHING 1-30# FELT OVER 15/32" PLYWD SHEATH'G 1-30# FELT OVER 15/32" SHINGLE ROOF ON (2-LAYER OVER PLYWOOD) GRADE "D" FELT ON METAL LATH OVER EXTERIOR STUCCO7/8" FOR OVERHANG SEE ROOF PLAN 2X FASCIA PROVIDE 2 X FIRE BLOCK " TYPE X GYP. BD.8 5 1-HOUR RATED WALL AND EAVE RAFTER 9/26/2024 TANK WATER HEATER DETAILS METAL WEEP SCREED DETAIL DATE SCALE DRAWN JOB SHEET OF SHEETS A-6.1 DESCRIPTION Details Finish Wall/Roof Architectural SANTA ANA, CA 92706 2726 STRAW BERRY LANE, UNIT 2 NEW DETACHED ADU SANTA ANA, CA 92706 2726 STRAW BERRY LANE ADDRESS: PRO JECT: 1 2 2 2726 W Strawberry Ln & Unit# 23/17/2025 E1 4'-0" TD1 TD1 1 8'-0" TD1 TD1 1 12 ' - 0 " TD1 TD1 1 12 ' - 0 " TD1 TD11 4'-0" TD1TD1 1 8'-0" TD1TD1 1 1 22 22 2 01 SD1 01 SD1 01 SD1 01 SD1 05 SD1 TYP. 05 SD1 TYP. 02 SD1 03 SD1 TYP. 03 SD1 TYP. 08 SD1 1 1 08 SD1 09 SD1 W/C B 4 4 W/C B 4 4 09 SD1 09 SD1 W/C B 4 4 W/C B 4 4 09 SD1 2'-0"SQ.X18" PAD W/ (4) #4 EAC. WAY@ BOTT. 07 SD1 TYP. 2'-0"SQ.X18" PAD W/ (4) #4 EAC. WAY@ BOTT. 2'-0"SQ.X18" PAD W/ (4) #4 EAC. WAY@ BOTT. 222 22 2 SL O P E PE R A R C H . SL O P E PE R A R C H . E 16 SD1 16 SD1 RB1 1 1 RR1 1 1 1 1 孷宻 孻季 宋 宇 宕 224T 224T 孷宛 孹 季 宋 宇 宕 孷宛孹季宋宇宕 孷宛孹季宋宇宕 孷宛孹季宋宇宕孷宛孹季宋宇宕 孷宛孹季宋宇宕 孷宛孹季宋宇宕 孷宛孹季宋宇宕 12 SD1 1 4'-0" 1 8'-0" 1 12 ' - 0 " 1 12 ' - 0 " 1 4'-0" 1 8'-0" 5 1/4" X 11 7/8" PSL 2.2E RIDGE BM. 2 CJ1 RB2 5 1/4" X 11 7/8" PSL 2.2E RIDGE BM. 10 SD1 11 SD1 11 SD1 10 SD1 10 SD1 11 SD1 11 SD1 13 SD1 66KP 13 SD1 46KP 19 SD1 46KP 4414 SD1 44 14 SD1 13 SD124KP 13 SD124KP 4414 SD1 44 14 SD1 R/ R W / E . N . 17 SD1 18 SD1 18 SD1 R/ R W / E . N . 17 SD1 5 1/4" X 7" PSL 1.8E CL'G BMCB1 RB3 1 3 / 4 " X 7 1 / 4 " L S L 1 . 5 5 E R I D G E B M . RB4 2X 8 D F L 2 R I D G E B M . 46 13 SD124 KP 3 1/2" X 9 1/4" PSL 2.2E RIDGE BM. B1 孷宛孷季宋宇宕 孷宛孷季宋宇宕 4X 6 D F L 2 B2 4X 6 D F L 2 B2 3 1/2" X 9 1/4" PSL 2.2E RIDGE BM. 4X 6 D F L 2 4X 6 D F L 2 H1 11 SN2 4611 SN2 06 SN2 TYP. 1 2X6 DFL #2 @ 16" O.C. ROOF RAFTERS FRAMING PLAN KEYNOTES: 2X6 DFL #2 @ 16" O.C. CEILING JOISTS SCALE: 1/4" = 1' FOUNDATION PLAN S-1 01 SCALE: 1/4" = 1' FRAMING PLAN S-1 02 2 1 2 12" (W) x 24" (D) CONT. FOOTING W/ (2) #5 (OR (3) #4) @TOP & BOTT. 5" THICK CONC.SLAB W/ #4 @18" O.C. ON CENTERS AT EA. WAY OVER 4" BASE OF 1/2" OR LARGER CLEAN AGGREGATE WITH 10 MIL VAPOR RETARDER IN DIRECT CONTACT WITH CONCRETE. SLAB SHALL BE TIED-IN TO CONTINUOUS 12" X 24" FOUNDATION. FOUNDATION PLAN KEYNOTES: INTERIOR BEARING WALL SHEAR WALL X LEN LENGTH TYPE Consultant: Address: Address Phone e-mail AD D R E S S : SHEET NAME DATE DRAWN BY: CHECKED BY: SHEET NUMBER REVISION STAMP PR O J E C T 9/ 3 0 / 2 0 2 4 NE W D E T A C H E D A D U LP 07/22/2024 HP 2 7 2 6 S T R A W B E R R Y L A N E , U N I T 2 Description Date SA N T A A N A , C A 9 2 7 0 6 2 7 2 6 S T R A W B E R R Y L A N E SA N T A A N A , C A 9 2 7 0 6 FOUNDATION PLAN NOTES 1. ALLOWABLE SOIL BEARING PRESSURE = 1000 PSF 2. SEE SPECIFICATIONS ON SHEET SN1 FOR ADDITIONAL INFORMATION. 3. CEMENT USED IN THE FOUNDATIONS SHALL BE TYPE II. UNLESS OTHERWISE REQUIRED BY THE SOIL ENGINEER. 4. THE FLOOR SLAB SHALL BE POURED LEVEL TO WITHIN 1 8 INCH IN 10 FEET. 5. THE FLOOR SLAB AND FOUNDATION MAY BE POURED HOMOGENEOUSLY (AT THE SAME TIME), WITH A COLD JOINT BETWEEN THE SLAB AND FOUNDATION, AT THE CONTRACTOR DECISION. THE DETAILS DRAWN GENERALLY SHOW TWO POURS. 6. ANCHOR BOLTS: AT ALL EXTERIOR WALLS, INSTALL A 5 8" DIA. ANC. BOLTS @6'-0" O.C. U.N.O. W/ MIN. 7" EMBEDMENT AND W/ 3"x3"x0.229 THK. PLATE WASHER (THE HOLE IN THE PLATE WASHER IS PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 1/16 INCH LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT TO EXCEED 1% INCHES, PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT) INCLUDING AT LEAST ONE WITHIN A MAXIMUM OF 11 7/8" FROM EACH END. PLATES SMALLER THAN 24" IN LENGTH, SHALL BE PROVIDED WITH AT LEAST TWO ANCHOR BOLTS UNLESS OTHERWISE INDICATED ON PLANS. PROVIDE ALL EXTERIOR WALLS AS INDICATED ON PLANS. SEE FLOOR FRAMING PLAN FOR REFERENCE IN PROVIDING AN EXTENSION OF ANCHOR BOLTS ABOVE CONCRETE. HARDWARE SHALL BE TIED IN-PLACE PRIOR TO PLACEMENT OF CONCRETE. 7. SHOT PINS: AT ALL INTERIOR, NON-BEARING, NON SHEAR WALLS AND PARTITIONS, INSTALL A 0.145" DIA. x 2.875" LONG, SHANK AND METAL PLATE WASHER AT 36" O.C. ADDING ONE AT EACH END. PLATES SMALLER THAN 16" OR LONGER AND INDICATED AS SHEAR WALLS, PLACE TWO ADDITIONAL FAASTENERS, ONE AT 6" AND ANOTHER AT 10" FROM EACH END. 8. HOLDOWNS: SEE FOUNDATION PLAN OR FLOOR FRAMING PLAN FOR REFERENCE TO HOLDOWN LOCATION AND HARDWARE EXTENSION TO CONCRETE FOUNDATION. (SEE DETAILS PER PLAN FOR MORE INFORMATION) 9. RESIDENTIAL FLOOR SLAB: PLACE SLAB REINFORCEMENT IN CENTER OF SLAB. REINFORCEMENT SHALL BE CHAIRED AND TIED IN PLACE PRIOR TO PLACEMENT OF CONCRETE. A VISQUEEN VAPOR BARRIER SHALL BE PLACED AT ALL MOISTURE SENSITIVE FLOOR AREAS. PROVIDE SEAMS WITH AT LEAST 6" OVERLAP AND SEAL TAPE. 10. REFER TO ARCH. DWG. FOR TOP-OF-SLAB ELEVATIONS. 11. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AND SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES OR INCONSISTENCIES WITH ANY WORK SO INVOLVED PRIOR TO STARTING CONSTRUCTION 12. CONSULT ENGINEERING FOR TWO-POUR CONDITION. 13. WHERE TOP PLATE OR SOLE PLATES ARE CUT FOR PIPES, A METAL TIE MINIMUM 0.058" THK. AND 1 1/2" WIDE SHALL BE FASTENED TO EACH PLATE ACROSS AND TO EACH SIDE OF THE OPENING WITH NOT LESS THAN 6-6d NAILS. 14. ALL SHEAR HARDWARE AND ANCHOR BOLTS WITH NON-STANDARD SPACING ARE TO BE FIXED IN PLACE FOR THE FOUNDATION INSPECTION. INDICATE HOLD-DOWN LOCATIONS, ANCHOR BOLTS WITH NON-STANDARD LENGTH OR SPACING. 15. THE STRUCTURAL DESIGN OF THE FOOTING IS BASED ON A SPECIFIED COMPRESSIVE STRENGTH NO GREATER THAN 2500 PSI. SPECIAL INSPECTION WILL NOT BE REQUIRED. 16. FASTENERS AND CONNECTORS TO BE GALVANIZED FOR PRESERVATIVE TREATED WOOD. FRAMING NOTES 1. REFER TO STRUCTURAL GENERAL NOTES SHEET SN1 FOR MORE INFORMATION 2. SEE 10/SN2 FOR FLOOR & ROOF DIAPHRAGM, a. ROOF SHEATHING: AS PER R602 C.R.C. 15/32" PLYWOOD W/ 8d @6:6:12 (COMMON NAIL) PANEL SPAN RATING 24/0 OR BETTER b. FLOOR SHEATHING: 23/32" PLYWOOD W/10d @ 6:6:12 (COMMON NAIL) PANEL SPAN RATING 32/16 OR BETTER 3. MULTIPLE ELEMENT MEMBERS (i.e. DBL JOISTS, DBL. STUDS, etc.) SHALL BE NAILED TOGETHER W/16d's @8" O.C. STAGGERED. BEAMS COMPOSED OF MULTIPLE PIECES (4x OR LARGER) SHALL BE BOLTED TOGETHER W/ 5/8"Ø M.B.'S @16" O.C. STAGG. 4. WALL STUDS: a. SIZE OF EXTERIOR AND INTERIOR STUD WALLS SHOULD MATCH WITH ARCHITECTURAL DRAWINGS. b. CONSIDER THE FOLLOWING MINIMUM REQUIREMENTS: xxx ALL INTERIOR WALLS SHALL BE 2x4 STUDS @16" O.C., U.N.O. xxx WALLS W/ UNSUPPORTED HEIGHT OF MORE THAN 10'-0", SHALL BE 2x6 STUDS @16" O.C. 5. WHERE HANGERS ARE NEEDED, WHETHER INDICATED ON PLAN OR NOT, U.N.O. SEE "U" OR "LB" HANGERS FOR JOISTS/RAFTERS, & "HU" OR "HW" HANGERS FOR BEAMS OR MULTIPLE JOISTS. 6. WHERE SHEAR WALLS ARE THRU WALLS AS INDICATED ON PLANS, SHEAR MATERIAL SHALL BE CONT. THRU WALLS. 7. ALL POSTS/MULTIPLE STUDS IN WALLS SHALL RECEIVE EDGE NAILING FROM WALL SHEATHING. ALL BEAMS, DRAG GIRDER TRUSSES SHALL RECEIVE BOUNDARY NAILING FROM SHEATHING. 8. WHENEVER A DETAIL IS CALLED ON A WALL LINE (FOR EXAMPLE, 1/SD1 WITH A35'S @24" O.C.), IT NEEDS TO BE APPLIED TO THE FULL LENGTH OF THAT WALL. NOT JUST AT THE SPOST IT IS KEYED OUT OR JUST AT SHEAR PANEL PORTION OF THE WALL. 9. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING, FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. 10. WHERE TOP PLATES OR SOLE PLATES ARE CUT FOR PIPES, A METAL TIE MINIMUM 0.058" THK. AND 1 1/2" WIDE SHALL BE FASTENED TO EACH PLATE ACROSS AND TO EACH SIDE OF THE OPENING WITH NOT LESS THAN 6-16d NAILS. 11. COORDINATE AND VERIFY ALL DIMENSIONS WITH ARCHITECT DRAWINGS. FOUNDATION PLAN S1 FRAMING PLAN (PLF) SHEAR ALLOWABLE 220 2022 CALIFORNIA BUILDING CODE (1), (3) SHEAR WALL SCHEDULE PANEL TYPE SHEAR 8 d's @ 4" O.C. NAILING (COMMON) EDGE 8 d's @ 6" O.C. 3/8" APA rated rated 3/8" APA SHEATHING 8 d's @ 12" O.C. @ 12" O.C. 8 d's FIELD (COMMON) NAILING (4) (2)@ 4" O.C. @ 6" O.C. @ 16" O.C. @ 12" O.C. @ 24" O.C. @ 16" O.C. FRAMING CLIPS A35's, LS50's OR LTP5's (5), (6)(8) 260 320 380 (9) (7) (7) SILL PLATE CONNECTION SINKER 16d's SCREWS RIM BOARDLSL & DF 1/4"Øx6" SDS SCREWS RIM BOARDLVL 1/4"Øx6" SDS @ 14" O.C. @ 10" O.C. 1 2 NOTE: REFER TO SHEAR WALL SCHEDULE ON SHEET SN1 FOR DETAILS AND NOTES NOT SHOWN 2X4 @16" O.C. STUD WALL XX X ANCHOR BOLT SPACING (IN) NUMBER OF ANCHOR BOLTS NOTES: 1. SCARIFY TOP 12" OR RECOMPACT 4' OVEREXCAVATION PRIOR TO TRENCHING FOR THE UTILITY AND/ OR FOUNDATION. 90% COMPACTION REPORT IS REQUIRED AT THE TIME OF FOUDNATION INSPECTION. DAMP PROOFING, BASE COURSE AND PRE-SATURATION ARE REQUIRED. 2. ALL CONCRETE SHALL BE f'c = 2500 PSI MIN. WITH TYPE V CEMENT. MAXIMUM WATER CEMENT RATIO OF 0.45. 3. LINE AND GRADE CERTIFICATE SHALL BE SUBMITTED TO THE BUILDING INSPECTOR PRIOR TO FOUNDATION INSPECTION. 4. SOIL COMPACTION REPORT SHALL BE SUBMITTED TO THE BUILDING INSPECTOR AT THE TIME OF FOUNDATION INSPECTION FOR ALL NEW CONSTRUCTION AND/OR ADU PROJECTS. NOTES: 1. WHEN SOLAR PANEL IS REQUIRED, SOLAR PLANS SHALL BE REVIEWED AND APPROVED BY BUILDING DIVISION PRIOR TO ROOF SHEATHING INSPECTION. 224 2-2X4 STUDS 44 4X4 DFL#2 POST 46 4X6 DFL#2 POST TD1 SIMPSON HDU2 24T 2X4 TRIMMER 224T 2-2X4 TRIMMER 66 6X6 DFL#1 POST CALIFORNIA FRAMING SIGNED DATE: 9/30/2024 SOIL ENGINEER REVIEW 2/21/25 2726 W Strawberry Ln & Unit# 23/17/2025 SEE TABLE. END LENGTH 6'-0" * SEE FRAMING PLAN. CONT. JOIST OR BLOCKING,7. OF EDGE NAILING SEE PLAN.BEAM OR JOIST (S), W/ LINE6. 5. 4. 1. 2. 3. 3'-0" 3'-0" 6'-3" CAPACITY 1700# 3400# 4585# 6490#D CMST14 NAIL SIZE AND SPACING BEAM/ JOIST (S). PLAN. FOR CONDITION C &D. MIN. 3 1/2" WIDE MEMBER ROWS OF NAILS.MIN. 1/2" SPACING BETWEEN C CMSTC16 B* (2) CS16 A CS16 STRAP DBL. TOP PLATE. POST OR MULTI STUD, SEE SPACING AND END LENGTH SIMILAR CONDITION (FLUSH SIMPSON STRAP PER TABLE133273 5 6 4 10d BOX AT 3 1/2" 10d BOX AT 4 1/2" 8d BOX/SINKER AT 4 1/8" 8d BOX/SINKER AT 4 1/8" REFER TO 17/SN2 FOR CS16 NAILING PATTERN. - - NOTES: (2) ROWS OF NAILS FOR EA. STRAP. DRAG DETAIL 6 3 4 1 PLYWOOD SHEATHING 2-16d TOE NAIL EACH RAFTER TYPICAL ROOF RAFTER PER 5. 6.2 EDGE NAILING 3. 2. TO RIDGE PLAN 1.RIDGE PER PLAN SIMP. ST6236 STRAP @ 48" O.C.,FULLY NAIL STRAP W/ 16d SINKER OR 10 d's COMMON NAILS 5 CONNECTION DETAIL 2" DEEPER THAN ROOF RATER 4. 1.BEAM PER PLAN 2 3 TYP. @ EACH SIDE OF BEAM O.C. STAGGERED TO POST 2X KING STUD W/(3) 16d's TO SIDE OF BEAM & 16d's @ 12" 1 2. 3. POST PER PLAN BEAM CONNECTION DETAIL CENTER @ PENETRATION ADD (2) #4 X 4' LONG TRENCH PERPENDICULAR TO FOOTING TO FOOTINGSTRENCH PARALLEL FILL COMPACTED 4 MI N . MI N . 6" 6" PROPER SHORING NOTES: RESPONSIBLE FOR CONTRACTOR IS CREATE PIPE SLEEVE 2" LARGER THAN PIPE. LINE. NOT TO EXTEND BELOW THIS BOTTOM OF TRENCH EXCV. PER SOILS REPORT. BACKFILL TRENCH EXCV. FINISH GRADE.4. 3. 2. 1. TYP. TRENCH @ FOOTINGS D5117 1 3 10'-0" MIN. 18" 1 2 1 2 2 R WHEN REQUIRED. FOR VERTICAL PIPES:5. 2X4 WALLS - MAX. PIPE SIZE IS 3". 5 2X6 WALLS - MAX. PIPE SIZE IS 4". - MIN. SPACING OF- OF VERTICAL PENETRATION IS 6". 3/4" MIN. Consultant: Address: Address Phone e-mail AD D R E S S : SHEET NAME DATE DRAWN BY: CHECKED BY: SHEET NUMBER REVISION STAMP PR O J E C T 9/ 3 0 / 2 0 2 4 NE W D E T A C H E D A D U LP 07/22/2024 HP 2 7 2 6 S T R A W B E R R Y L A N E , U N I T 2 Description Date SA N T A A N A , C A 9 2 7 0 6 2 7 2 6 S T R A W B E R R Y L A N E SA N T A A N A , C A 9 2 7 0 6 A.B. EDGE DISTANCE 'b' = 2 3/4" FOR 2x6 'b' = 1 3/4" FOR 2x4 8" MI N . 2" CLR. 3" CL R . 'b' STUD WALL ON EXT. GRADE BEAM d f e p WEEP SCREED. (MIN. 4" ABOVE GRADE 2X STUDS @ 16 " O.C. CONT. REBAR T&B PER TABLE (U.N.O.). INTERIOR FINISH. WHERE INDICATED ON PLANS) W/ 5/8" DIA. ANCHOR BOLTS 5" CONC. SLAB W/ #4 BARS a. b. f. e. d. 2X P.T.D.F. SILL (USE 3Xc. SLAB. U.N.O. @ 18" O.C. E/W @ MID HT. OF 7" EMBEDMENT. (FOR DUAL POUR, THEp. h.EXTERIOR FINISH W/ G.I. BASE r q. PLYWOOD PER PLAN. r. TOP OF NATURAL GRADE OR COMPACT FILL. PRESATURATION TO OR MASA/MASAP. MIN. 10 MIL VAPOR BARRIER WITH OVER JOINTS LAPPED NOT LESS THAN 6 IN. 7" EMBEDMENT INTO THE 1st. POUR STARTS FROM THE COLD JOINT). b a c q W D h - VAPOR BARRIER TO HAVE PER MANUF. (U.N.O.). NOTES: USE #4 DOWELS 24" @ 36" O.C. FOOTING DIMENSIONS/REINF. U.N.O. # OF STORIES W WIDTH D DEPTH 1 12"24" 24" EMBED MIN. 12" ON FIRST POUR FOR DUAL POUR LOWEST ADJACENT GRADE. - "D" IS EMBEDMENT DEPTH BELOW 2-#5 TOP & BOTTOM CONTINUOUS REBAR "e" s s. SLAB ON GRADE WHERE OCCURS z t. NOT USED t x. OPTIONAL CURB y. y CONT. #4 REBAR MIN. 6" LAP AT ALL SEAMS x z. 3" MIN. 1' - 0 " M I N . V @VENEER MATCH ITS THICKNESSv. OR 3-#4 TOP & BOTTOM AGGREGATE 110% OF OPTIMUM MOISTURE CONTENT. OVER 4" BASE OF 1/2" OR LARGER CLEAN AND 2" ABOVE PAVE AREAS). 4" MI N . 3" CLR. 3" CL R . "L e " W D INT. BEARING FOOTING a q - SEE DETAIL #1 FOR LEGEND & INFORMATION NOT SHOWN. NOTES: d c e f z NOTE: SEE DETAIL #1 FOR LEGEND & INFORMATION NOT SHOWN NON-BEARING INTERIOR WALL d 1 a 1.FOR INTERIOR NON-SHEAR WALLS USE SIMPSON PDPAWL-MG SERIES 0.157Ø PINS WITH A PENETRATION OF 1 1/4" INTO SLAB AT 16" O.C. TO BE INSTALLED IN ACCORDANCE WITH ICC ESR-2138. ACTUAL SLAB THICKNESS TO BE MINIMUM 4". PLATES SMALLER THAN 16" IN LENGTH SHALL HAVE MINIMUM OF TWO FASTENERS. NOTE: INFORMATION NOT SHOWN. SEE DETAIL #1 FOR LEGEND AND 2. #3 X 24" DOWELS @ 24" O.C. 1. SEE DETAIL #3 HOUSE TO PORCH 3" CL R . e r D d 2" MI N . PORCH SLAB SLOPE TO DRAIN 6" MIN. FINISH GRADE 6" MI N . FACE OF STUDS12 W 3" CLR 4" NOTES: AND INFORMATION NOT SHOWN - SEE DETAIL #1 FOR LEGEND EXTERIORINTERIOR STUD FACE OF SEE PLANS 24" SQ. MIN. SEE PLANS PAD REINFORCEMENT,2. 1. COLUMN BASE, SEE PLAN POST IN WALL OR USE 1 2 2 d -4x4 POSTS CAN BE REPLACED WITH 2-2x4 AS LONG AS NAILS ARE MAINTAINED WITH MIN. EDGE DISTANCE AS REQUIRED BY THE MANF. SPEC. & S.W. EDGE NAILS STAGG ON BOTH STUDS. 3" CL R . SEE PLANS 24" SQ. MIN. FACE OF PAD FOOTING 1 1. ROOF SHEATHING. ROOF RAFTER RSRS 03 NAILS AT 6" O.C. B.N. U.N.O. 2X FULL HEIGHT BEVELED BLK'G DBL. TOP PLATE OR BEAM. SIMPSON A35 SPACING 2. 3. 4. 5. 6. SHEAR TRANSFER DETAIL PER SW SCHEDULE (AT NON-SHEAR WALL, SPACING IS 48" O.C. MAX.). 2 3 4 5 6 SHEAR PANEL WHERE OCCURS7. 7 11 8. 9 2X C.J. WHERE OCCURS. SEE ARCH.9. 8 2X STUDS @ 16" O.C. TYP. 10 W/ 3-16d EAC. END TO JOISTS 2X FASCIA BOARD W/ 3-16d TYP.10. 11 5-16d COMMON NAILS TYP.11. @ EA. C.J. TO R.R. 9" TYP. HOLDOWN, SEE PLAN FOR TYPE AND LOCATION "L e " 9" TYP. SDS SCREW WHERE REQ'D 2X OR 2-2X TRIM 4X MIN. U.N.O. E.N. TO HOLDOWN SILL PLATE SILL BOLT HOLDOWN ANCHOR SEE SCHEDULE SEE NOTE #3 6" MIN. VARIES SEE MFGR POST WHERE REQ'D CONCRETE CURB FF HOLDOWN ANCHOR SEE SCHEDULE SILL BOLT SILL PLATE HOLDOWN, SEE PLAN FOR TYPE AND LOCATION 4x MIN. U.N.O. SEE NOTE #3 6" MIN.4" MI N . VARIES SEE MFGR "L e " "L e " SEE NOTE #3 1 3/4" AT 2x4 STUDS 2 3/4" AT 2x6 STUDS INTERIOR WALLA AT CONCRETE CURBB EXTERIOR WALLC INTERIOR WALLD HOLDOWN AND EMBEDMENT SCHEDULE (MIN. 2500 PSI CONCRETE) MODEL NO HDU2-SDS2.5 HDU4-SDS2.5 HDU5-SDS2.5 MINIMUM POST SIZE 2-2X (4X @ CORNER) 2-2X (4X @ CORNER) 2-2X (4X @ CORNER) ANCHOR BOLT SIZE 5/8" 5/8" 5/8" MIN. EMBED "Le" 21" 18" 18" ANCHOR * TYPE SSTB24 SB5/8X24 SB5/8X24 CAPACITY (LBS.) CORNER 3325 5730 5730 3325 5730 5730 END * MATERIAL OF SSTB & SB IS ASTM F 1554 GRADE 36 PER ICC ESR-2611 * * NOT APPLICABLE FOR HOLDOWN LOCATION @ CORNER OR END NOTES: 1. BOLT HOLD DOWN TO POST PER MFGR, PROVIDE STANDARD CUT WASHERS ON OPPOSITE SIDE OF POST FROM HOLDOWN. POST MAY BE COUNTER SUNK A MAXIMUM OF 12 INCH TO RECESS BOLT AND WASHER. TYP. HOLDOWN INSTALLATION 4" MI N . NOTE: PLYWOOD NOT SHOWN FOR CLARITY NOTES: 4x4 POSTS CAN BE REPLACED W/ 2-2x4 AS LONG AS NAILS ARE MAINTAINED W/ MIN. EDGE DISTANCE AS REQUIRED BY THE MANUF. SPEC. BOTH STUDS. - PLAN VIEW SB/SSTB @ CONC. CORNER PLAN VIEW SB/SSTB @ CONC. END 85" MIN4 5" MIN. 4 16 " RE T U R N 7 MI N . & S.W. EDGE NAILS STAGGERED ON - FOR NON-MONO POUR FOUNDATIONS, USE (2) #5 DOWELS PER EACH SB/SSTB BOLTS, PLACED WITHIN 2" 18" 18 " FROM THE BOLT. TYP. WOOD POST ON SILL PLATER PRESSURE TREATED3. 2. 1. TOP OF CONC. SLAB POST SEE PLAN FOR SIZE 1 2 4 A35 @ EAC. SIDE OR BC PER PLAN4. 3 CONT. SILL PLATE CL 5 2X WALL STUD5. 1 4 5 1.BEAM, SEE PLAN FOR SIZE. DBL. TOP PLATE MULTI-STUD OR POST, SEE PLAN. SIMPSON A34. SILL PLATE. 2. 3. 4. 5. CEILING BEAM DETAILR 3 2 STRUCTURAL DETAILS SD1 CONNECTION AT KING POST 14 3 4 5 2 1. 2. 3. 4. 5. 16d NAILS AT 6" O.C. STAGG. EACH SIDE. 2X K. STUD EACH SIDE. ST12 EACH SIDE K. POST TO SUPPORTING BM. AS AN ALT. BM PER PLAN. KING POST. USE 2X K. STUD SIMILAR TO ABOVE. CONNECTION DETAIL POST W/ SIMPSON ECCQ OR PROVIDE SHIM UNDER AND @THE SIDE OF THE SMALLER BEAM AS REQUIRED. POST W/ SIMPSON CCQ OR ALIGN BEAMS TO RECEIVE ALT. LOCATION OF STRAP ON TOP OF BEAMS. NOTES: -STRAP. 2. 3. 4. CC , SEE PLAN. 1. CENTERED SIMPSON ST6236 1 1 2 3 1 433 ECC, SEE PLAN. - MULTI - STUD OR 71 1. 4. 3. 2. (2) #4 E/ W PER PLAN. OF COLUMN BASE.12" 12" THRU STIRRUP #3 MIN. "V" BAR BENT CB/LCB/CBSQ PER PLAN. SIMPSON COLUMN BASE 2 WHERE OCCURS. 1 WHERE OCCURS. 1" 7. 6. 5 CL R TOP OF CONCRETE SLAB PAD FOOTING PER PLAN. 2 PLATE & ANCHOR BOLTS5. 3CLR3" 3" 38" M I N . 4 6 4" 3" BATTER SEE PLANS POST PER PLAN. COLUMN BASE DETAIL SHEAR TRANSFER DETAIL 11. 8. 6. 10. 9. 7. 5. 3. ROOF SHEATHING W/ LINE OF 2X FLAT OUTRIGGERS @ 4'-0" O.C., FOR EAVES UP TO 24" DO NOT 4. E.N. @ BLOCKING. 1. 2. RAFTER WHERE OCCURS TO RUN FOR EAVES UP TO 12" & 2'-0"O.C. OVER CUT. NAIL W/ (2) 16d's @ EACH END. R 6 6 1 2-2X TOP PLATES, WHERE OCCURS 2X STUDS @ 16" O.C. TYP. 3 2 SHEAR PANEL WHERE OCCURS 3 10 7 2X BLK'G @ 48" O.C. 8 A35 PER SHEAR WALL SCHEDULE 9 9 2X C.J./BLK'G WHERE OCCURS. B.N. 4 2X FLAT OUTIGGER @ 24" O.C. 11 2X FASCIA W/ 2-16d E.N. @ EAC. OUTRIGGER W/ B.N. @ ROOF SHEATHING & W/ 2-16d E.N. @ EAC. END (3) 8d COMMON TOE NAILS TO TOP PLATES OR 48" O.C. @ NON-SHEAR WALL 12 12.PROVIDE 2X BRACING @ 48" O.C. WHEN WALL STUDS ARE NOT CONTINUOUS. 1 A B B 4 3 1 6 A 1 5 4 23 CALIF. FRM'G (PLAN VIEW) CONNECTION DETAIL 2x 6 R I D G E ( U . N . O . ) CALIF. FRAM'G. @ RIDGE B.N. MI N 1 2 " 1.R/R OR TRUSS PER PLAN. ROOF SHEATHING. MIN. 1X CONT. BOARD W/ (3)16d's TO EACH ROOF FRAMING ELEMENT. 2X R/R @ CA. FRAMING. USE 2X4 @ 24" O.C. FOR MAX. SPAN OF 6'-0" & 2X6 @ 24" O.C. FOR MAX. SPAN OF 10'-0". 2X6 PURLIN & 2X4 KICKER @ 8'-0" O.C. MAX. TO LIMIT R/R SPAN @ CALIF. FRAMING. (1) BAY WIDTH X 30" ACCESS & VENTILATION OPENING PER ARCHITECTURAL. PROVIDE 2X BLKG. & BOUNDARY NAILING OF ROOF SHEATHING AROUND OPENING. 2. 3. 4. 5. 6. & TOE NAIL W/ (3) 8d's. CC CALIFORNIA FRAMING DETAIL DRAG DETAIL A CS16 1700# 3'-6" B (2)CS16 3400# 3'-6" END LENGTHSTRAPCAPACITY** OF 8d SINKER NAILS @ 4 1 7 1 5 2 62 3 END LENGTH.7. 7 CS16 & NAIL W/16d's @ 4" O.C. MEMBER TO RECEIVE 2ND.ADD 2"X4"X48" LONG* STAGGERED TO ROOF TYPICAL ROOF RAFTER WHERE APPLICABLE.ALL BAYS OF BLOCKING. HIP BEAM SEE PLAN FOR NO. OF BAYS 2X FLAT BLK'G. W/ E.N. ALONG LINE OF DRAG. DBL. TOP PLATE OR BEAM. ROOF SHEATHING W/ E.N. (MIN. 4 BAYS). 6. 5. 4.2 2. 3. 7 SIMPSON CS16 W/ (2) ROWS1. * RAFTER/TRUSS TOP CHORD. 4 1/8" O.C. CUT TO FIT OVER SIGNED DATE: 2/20/2025 3 3 BLDG PC 3 02/20/25 40*-&/(*/&&33&7*&8 2726 W Strawberry Ln & Unit# 23/17/2025 Consultant: Address: Address Phone e-mail AD D R E S S : SHEET NAME DATE DRAWN BY: CHECKED BY: SHEET NUMBER REVISION STAMP PR O J E C T 12 / 8 / 2 0 2 4 NE W D E T A C H E D A D U LP 12/08/2024 HP 2 7 2 6 S T R A W B E R R Y L A N E , U N I T 2 Description Date SA N T A A N A , C A 9 2 7 0 6 2 7 2 6 S T R A W B E R R Y L A N E SA N T A A N A , C A 9 2 7 0 6 1ST PC RESPONSE 12/08/241 & Χ & TYP. BORE & NOTCH @ PLATES 01 TYP. BORE & NOTCH @ STUD SUPPORT C OFL 1 1 NOTCHING BORING TYP. BORE & NOTCH @ BM OR JOIST 03 D/ 4 D/ 3 MA X D/ 6D 2" MI N . D 2" MI N . D D/ 6 02 TYP. SHEAR WALL INTERSECTIONS 09 TYP. REINFORCING BENDS 13 TYPICAL REINFORCEMENT DETAILS 05 05 SN2 STRUCTURAL DETAILS SD2TYP. EXTERIOR AND INTERIOR BEARING/SHEAR WALL FRAMING TYP. INTERIOR NON-BEARING STUD WALL FRAMING 16 ALT. CONDITION PROVIDE B.N. @ ALL EDGES. 24". PROVIDE ADEQUATE FRAMING MEMBERS TO LIMIT SPAN. SHEATHING. -SEE GENERAL NOTES FOR PLYWOOD TYPE, THICKNESS, SPACING, & NAIL SIZE. -PROVIDE MIN. 3/8" EDGE DISTANCE @ FRAMING MEMBER & 5/16" TO EDGE OF PLYWOOD DIAPHRAGM. -ALL DIAPHRAGM BOUNDARIES SHOULD BE FULLY SUPPORTED BY FRAMING MEMBERS W/ BOUNDARY NAILING -T&G EDGE TO BE LOCATED OVER CONTINUOUS PANEL JOINT. -MAX. UNSUPPORTED SHEATHING TO BE DIAPHRAGM OPENING IN TYP. APPROVED HANGERS USE (3) 16d TOE NAILS IF LENGTH NOTES: -STAGGERED JOINTS AS SHOWN -NAILS SHALL BE DRIVEN TIGHT BUT SHALL NOT FRACTURE SURFACE OF TAIL JOIST/TRUSS PER PLAN. TYP. 2-BAYS OF BLKG. USE CS16 OVER BLK'G AND OF TAIL JOIST < 6'-0". 16. 17. 18. 8. DISCONTINUOUS PANEL EDGE, EDGE NAILING PER PLAN. CONT. PANEL EDGE W/ BLKG. (IF BLOCKED DIAPHRAGM), EDGE NAILING PER PLAN. 24" MIN. UNLESS FULLY FIELD NAILING PER PLAN. FRAMING MEMBERS. DIRECTION OF FACE GRAIN PERPENDICULAR TO SUPPORT. BLOCK OUT EDGES OF THE OPENING W/ DBL. STRUCT'L. MEMBERS/BEAM (U.N.O.) AND 12. 13. 14. 15. 1/8" GAP U.N.O. 9. 10. 11. BLOCKED @ ALL EDGES. ROOF OR FLOOR SHEATHING. 2X4 W/ NAILS TO BE ROOF OR FLOOR FRAMING 2X4 BLK'G 6'-0" LONG MAX W/ (2) 16d PANEL EDGE WHERE 2X FLAT BLKG. IS NEEDED @ BLOCKED DIAPHRAGM BOUNDARY & COMMON NAILS @ EA. END. MATCHED W/ EDGE NAILING. 6. 7. DIAPHRAGM. B.N. PER PLAN. 3. 4. 5. 2. 1. MEMBER. PANEL JOINT. 1 3 4 2 6 14 7 8 9 10 11 13 10 18 17 12 16 15 1/8" GAP 16" MIN. OFFSET EDGE SUPPORT NAIL @ 2 1/16" O.C. U.N.O. 48" MAX.48 " MA X . ON FRAMING PLAN. PROVIDE SINGLE BLOCKING W/ E.N. WHEN OPENING < 24"x24", AND STRAPS PER NOTE 18 DO NOT APPLY. 51/8" GAP 79 10 8 6 3 2 5 42 3 42 3 2 1 1 1 1.BOTTOM CHORD OF TRUSS (MAX. @ 24" O.C.) 2. 3. 4. 2X8 BRACING. 5. 6. 7. 8. 9. SIMP. STC @ EACH CONNECT. IX OVER 2X PLATE OR (2) 2X BLK'G. @ 24" O.C. W/ (2) 16d's TO EACH MEMBER. 2X MEMBER W/(2) 16d TO BLK'G. (2) 2X TOP PLATE. (2) 16d'S @ 12" O.C. TYP. EDGE NAILING. 2X TOP PLATE WHEN TRUSS BOT. CHORD IS CAMBERED 10.2X CEILING JOIST OR BOTTOM CHORD OF CAMBERED TRUSS. ALT. CONDITION PERPENDICULAR PARALLEL 3 4 111 ALT. CONNECTION 2X BLK'G. X 12" LONG @ ±6'-0" O.C. NAILED TO TOP PLATE 11. W/ (3) 16d's. NON-BEARING WALL DETAIL 06 TYPICAL SPLICE TOP PLATE 08 14 PLY. FLR/ROOF DIAPHRAGM TYP.10 FLOOR SHTG 11 1 / 8 " 1 1/4" RIM JST 1 3 / 4 " 3 5 / 8 " LS50 PER 2x STUDS @ 16" O/C PENETRATION DBL TOP FL 2x STUDS @ 16" O/C NOTE: - PROVIDE F.H. SOLID BLOCKING UNDER BEAMS OR POST ABOVE. - NEED TO BE REVIEWED BY STRUCTURAL ENGINEER IF THE RIM JOIST SUPPORTS MORE THAN ONE FLOOR AND ROOF. PLANS Ø = 7 3/8" MAX 6 1 / 2 " 13"x6 1/2" DUCT OPENING L = 1'-1" S = 1'-1" MIN. MI N . EQEQ CL DUCT RIM OPENING @ MULTI DUCT 04 1/ 2 " 1 1 / 4 " NAILS 2 1/16" 07CS16 DRAG STRAP NAILING PATTERN NAIL BOTH PLWD. PANELS ON SAME MEMBER. BOTH SIDES OF DBL. SIDED WINDOW SILL FOR STRAP ON INSTALL HOLDOWN ON RETURN SHEAR PANELS. APPLICABLE. USE FULL WIDTH BLK'G. & WALL @ CORNERS WHEN NOTES: FULL LENGTH OF SHEAR PANEL). WINDOW SILL WHERE OCCURS. CONT. STUD/S OR POST W/ B.N. SHEAR PANEL TYPE PER PLAN ALL AROUND OPENING. PROVIDE BLK'G ABOVE & BELOW OPENING TYP. EACH CORNER OF OPENING. SILL & ACROSS SHEAR PANEL EXTEND ONTO HDR. OR WINDOW 2X BLK'G W/8d @ 2 1/16" O.C. CS16 OVER SHEAR PANEL OVER 3.2X STUD PER PLAN. NAILING/SCREWS/BOLT SHEAR WALL. B.N. AT BLK'G & EDGES OF HEADER PER PLAN. & W/HOLDOWN PER PLAN AT 8. 7. 6. 5. 4. DOUBLE 2X TOP PLATE. (ALT. INSTALL OVER 2X MIN. 2. 1. 16 835 2 6 1 7 4 5 6 18" 5 5 3 4 2 1 1 5 4 5 OUTSIDE EDGES OF SHEAR PANEL & EDGES OF DOORWAYS. 5 7 1 NAILING PATTERN. REFER TO 17/SN2 FOR CS16 PER PLAN.- - - - STAGGERED FACE NAILS PER9. NOTE 5 OF DETAIL 2/SN3. PANEL EDGE.10. 9 9 10 1/8" 10 USE (2)CS16 W/ (2)-2x or 4x BLKG11. AT KEY NOTE 15A 11 11 OPENING @ SHEAR WALL 11 12 15 HEADER SCHEDULE (SEE NOTE 1) OPENING WIDTH HEADER UP TO 3'-6"4X4 UP TO 5'-5"4X6 UP TO 6'-10"4X8 UP TO 8'-5"4X10 UP TO 9'-9"4X12 DATA FROM CRC TABLE R502.5(1) DF #1 HEADER, ALLOWABLE SPANS 3 2 4 2 4 1 SIDE VIEW END VIEW 1. BM., SEE PLAN. SIMPSON STRAP EACH SIDE OF BEAM TO POST. POST, SEE PLAN. ALT. TO MSTA12 STRAPS, USE 2X KING STUD EACH SIDE OF BEAM TO POST & NAIL W/ 16d'S @ 16" O.C. TO POST & MIN. (5) 16d'S TO BEAM. 2. 3. 4. NOTE: - POST & BEAM CONNECTION ADD SHIMS AS REQUIRED. IF THERE IS DBL. TOP PLATE- BTWN. BM. & POST, INCREASE LENGTH OF STRAP TO ACCOMMODATE. EQ . EQ . FILL ALL STRAP HOLES WITH- NAILS. 4 SIGNED DATE: 12/8/2024 2726 W Strawberry Ln & Unit# 23/17/2025 15 Bottom plate to joist, rim joist, band joist or blocking (at braced wall panels) 3-16d box (31/2″ × 0.135″); or 2-16d common (31/2″ × 0.162″); or 4-3” x 0.131 nails 16 Top or bottom plate to stud 4-8d box (2 ½” x 0.113”); or 3-16d box (31/2″ × 0.135″); or 4-8d common (21/2″ × 0.131″); or 4-10d box (3” x 0.128”); or 4-3” x 0.131 nails 3-16d box (3 ½” x 0.135”); or 2-16d common (3 ½” x 0.162”); or 3-10d box (3”x 0.128”); or 3-3” x 0.131 nails 17 18 Top plates, laps at corners and intersections 1″ brace to each stud and plate 3-10d box (3” x 0.128”); or 2 –16d common (3 ½” x 0.162”): or 3-3” x 0.131 nails 3-8d box (21/2″ × 0.113″); or 2-8d common (2 ½”x 0.131”); or 2010d box (3” x 0.128”); or 2 staples 1 3/4″ × 19 1″ × 6″ sheathing to each bearing 3-8d box (21/2″ × 0.113″); or 2-8d common (2 ½” x 0.131”); or 2-10d box (3” x 0.128”); or 2 staples, 1” crown, 16 ga., 1 3/4″ long 3-8d box (21/2″ × 0.113″); or 3-8d common (2 ½” x. 0.131”); or 3-10d box (3” x 0.128”); or 3 staples 1” crown, 16 ga., 1 ¾” long 20 1″ × 8″ and wider sheathing to each bearing Wider than 1” x 8” 4-8d box (2 ½” x 0.113”); or 3-8d common (2 ½” x 0.131”); or 3-10d common (3” x 0.128”); or 4 staples, 1” crown, 16 ga., 13/4″ long Floor 21 Joist to sill, top plate or girder 22 Rim joist, band joist or blocking to sill or top plate (roof application also) 23 24 25 26 1″ × 6″ subfloor or less to each joist 2″ subfloor to joist or girder 2″ planks (plank & beam - floor & roof) Band or rim joist to joist 4-8d box (21/2″ × 0.113″); or 3-8d common (2 ½” x 0.131”); or 3-10d box (3”x 0.128”); or 3-3” x 0131” nails 8d box (21/2″ × 0.113″) 8d common (2 ½” x 0.131”); or 10d box (3” x 0.128”); or 3” x 0.131” nails 3-8d box (21/2″ × 0.113″); or 2-8d common (2 ½” x 0.131”); or 3-10d box (3” x 0.128”); or 2 staples, 1” crown, 16 ga., 1 3/4″ long 3-16d box (3 ½” x 0.135”) 2-16d common (3 ½ ” x 0.162”) 3-16d box (31/2″ × 0.135″); or 2-16d common (3 ½” x 0.162”) 3-16d common (3 ½” x 0.162”) 4-10 box (3” x 0.128”), or 4-3” x 0.131” nails, or 4-3” x 14 ga. staples, 7/16” crown 20d common (4” x 0.192”); or 27 Built-up girders and beams, 2-inch lumber layers 10d box (3” x 0.128”); or 3” x 0.131” nails And: 2-20d common (4” x 0.192J; or 3-10d box(3 ½” x 0.128”); or 3-3” x 0.131” nails 28 29 Ledger strip supporting joists or rafters Bridging to joist 4-16d box (3 ½” x 0.135”); or 3-16d common (31/2″ × 0.162″); or 4-10d box (3” x 0.128”); or 4-3” x 0.131 nails 2-10d (3” x 0.128”), or 2-8d common (2 ½” x 0.131”; or 2- 3” x 0.131”) nails Face nail at ends and at each splice At each joist or rafter, face nail Each end, toe nail Face nail 3 each 16” o.c. face nail 2 each 16” o.c. face nail 4 each 16” o.c. face nail Toe nail End nail Face nail Face nail Face nail Toe nail 4” o.c. toe nail 6” o.c. toe nail Face nail Blind or face nail At each bearing End nail Nail each layer as follows: 32” o.c. at top and bottom and staggered. 24” o.c. face nail at top and bottom staggered on opposite sides. ITEM Roof 1 RESIDENTIAL NAILING SCHEDULE TABLE R602.3(1) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENERa, b, c Blocking between joists or rafters to top plate, toe nail 2 3 4 5 6 Ceiling joists to plate, toe nail Ceiling joists not attached to parallel rafter, laps over partitions, face (see Sections R802.3.2, R802.3.2 and Table R802.5.1(9)) Ceiling joist attached to parallel rafter (heel joint) (see Sections R802.3.1 and R802.3.2 and Table R802.5.1(9)) Collar tie to rafter, face nail or 11/4″ × 20 gage ridge strap to rafter Rafter or roof truss to plate 4-8d box (2 ½ x 0.113”)or 3-8d (21/2″ × 0.113″); or 3-10d box (3”x0.128”);or 3-3”x0.131” nails 4-8d box (2 ½ x 0.113”)or 3-8d (21/2″ × 0.113″); or 3-10d box (3”x0.128”);or 3-3”x0.131” nails 4-10d box (3”x0.128”);or 3-16d common (3 ½” x 0.162”);or 4-3”x0.131” nails Table R802.5.1(9) 4-10d box (3”x0.128”); or 3-10d common (3″ × 0.148″); or 4-3”x0.131 nails 3-16d box nails (31/2″ × 0.135″) or 3-10d common nails (3″ × 0.148″); or 4-10d box (3”x0.128”); or 4-3”x0.131” nails 7 Roof rafters to ridge, valley or hip rafters or roof rafter to minimum 2” ridge beam 4-16d (31/2″ × 0.135″); or 3-10d common (3″ × 0.148″); or 4-10d box (3”x0.128”); or 4-3” x 0.131 nails 3-16d box (31/2″ × 0.135″); or 3-16d common (31/2″ × 0.148″); or 3-10d box (3”x0.128”); or 3-3” x 0.131 nails Wall 8 9 10 11 12 13 16d common (3 ½ ″ × 0.162″) Stud to stud (not at braced wall panels)l Stud to stud and abutting studs at intersecting wall corners (at braced wall panels) Built-up header (2” to 2” header with 1/2″ spacer Continuous header to stud Top plate to top plate Double top plate splice 10d box (3” x 0.128”); or 3”x 0.131” nails 16d box (31/2″ × 0.135″); or 3” x 0.131” nails 16d common (3 ½” x 0.162”) 16d common (31/2″ × 0.162″) 16d box (3 ½” x 0.135”) 5-8d box (21/2″ × 0.113″); or 4-8d common (2 ½”x 0.131”); or 4-10d box (3” x 0.128”) 16d common (3 ½” x 0.162”) 10d box (3″ × 0.128″); or 3” x 0.131” nails 8-16d common (31/2″ × 0.162″); or 12-16d box (3 ½” x 0.135”); or 12-10d box (3” x 0.128”); or 12-3” x 0.131 nails 14 Bottom plate to joist, rim joist, band joist or blocking (not at braced wall panels) 16d common (3 ½” x 0.162”) 16d box (3 ½” x 0.135”); or 3” x 0.131” nails Toe nail SPACING OF FASTENERS Per joist, toe nail Face nail Face nail Face nail each rafter 2 toe nails on one side and 1 toe nail on opposite side of each rafter or trussi Toe nail End nails 24″ o. c. face nail 16” o. c. face nail 12″ o.c. 16” o.c. face nail 16″ o.c. each edge face nail 12” o.c. each edge face nail Toe nail 16” o.c. face nail 12” o.c. face nail Face nail on each side of end joist (minimum 24” lap splice length each side of end joint) 16” o.c. face nail 12 “ o.c. face nail MATERIALS 30 31 32 3/8" - 1/2" 19/32" - 1" 11/8" - 11/4" 6d common (2" × 0.113") nail (subfloor wall)j 8d common (21/2" × 0.131") nail (roof); or RSRS-01(2⅜” x 0.113” nail (roof) j 8d common nail (21/2" × 0.131"); or RSRS-01; (2⅜” x 0.113”) nail (roof)j 10d common (3" × 0.148") nail or 8d (21/2" × 0.131") deformed nail Other wall sheathing h 33 34 35 36 37 38 39 1/2" structural cellulosic fiberboard sheathing 25/32" structural cellulosic fiberboard sheathing 1/2" gypsum sheathingd 5/8" gypsum sheathingd 3/4" and less 7/8" - 1" 11/8" - 11/4" 11/2" galvanized roofing nail, 7/16" head diameter or 1¼” long 16 ga. Staple with 7/16” or 1” crown 13/4" galvanized roofing nail, 7/16" head diameter or 1½" long 16 ga. Staple with 7/16” or 1” crown 11/2" galvanized roofing nail; staple galvanized, 11/2" long; 11/4 screws, Type W or S 13/4" galvanized roofing nail; staple galvanized, 15/8" long; 1 5/8”screws, Type W or S 6d deformed (2" × 0.120") nail or 8d common (21/2" × 0.131") nail 3 3 7 7 Wood structural panels, combination subfloor underlayment to framing 6 8d common (21/2" × 0.131") nail or 8d deformed (21/2" × 0.120") nail 10d common (3" × 0.148") nail or 8d deformed (21/2" × 0.120") nail 6 6 6 6 7 7 12 12 12 Wood structural panels, subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing to framing (see Table R602.3(3) for wood structural panel exterior wall sheathing to wall framing) 6 6 6 12f 12f 12 Edges (inches) i Intermediate supports c, e (inches) FOR SI: 1 INCH = 25.4 MM, 1 FOOT = 304.8 MM, 1 MILE PER HOUR = 0.447 M/S; 1 KSI = 6.895 MPA. a.NAILS ARE SMOOTH-COMMON, BOX OR DEFORMED SHANKS EXCEPT WHERE OTHERWISE STATED. NAILS USED FOR FRAMING AND SHEATHING CONNECTIONS SHALL HAVE MINIMUM AVERAGE BENDING YIELD STRENGTHS AS SHOWN: 80 KSI FOR SHANK DIAMETER OF 0.192 INCH (20D COMMON NAIL), 90 KSI FOR SHANK DIAMETERS LARGER THAN 0.142 INCH BUT NOT LARGER THAN 0.177 INCH, AND 100 KSI FOR SHANK DIAMETERS OF 0.142 INCH OR LESS. b.STAPLES ARE 16 GAGE WIRE AND HAVE A MINIMUM 7/16-INCH ON DIAMETER CROWN WIDTH. c.NAILS SHALL BE SPACED AT NOT MORE THAN 6 INCHES ON CENTER AT ALL SUPPORTS WHERE SPANS ARE 48 INCHES OR GREATER. d.FOUR-FOOT BY 8-FOOT OR 4-FOOT BY 9-FOOT PANELS SHALL BE APPLIED VERTICALLY. e.SPACING OF FASTENERS NOT INCLUDED IN THIS TABLE SHALL BE BASED ON TABLE R602.3(2). f.WHERE THE ULTIMATE DESIGN WIND SPEED IS 130 MPH OR LESS, NAILS FOR WOOD STRUCTURAL PANEL ROOF SHEATHING TO GABLE END WALL FRAMING SHALL BE SPACE 6 INCHES ON CENTER. WHERE THE ULTIMATE WIND SPEED IS GREATER THAN 130 MPH, NAILS FOR ATTACHING PANEL ROOF SHEATHING TO INTERMEDIATE SUPPORTS SHALL BE SPACED 6 INCHES ON CENTER FOR MINIMUM 48-INCH DISTANCE FROM RIDGES, EAVES AND GABLE END WALLS; AND 4 INCHES ON CENTER TO GABLE END WALL FRAMING. g.GYPSUM SHEATHING SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH GA 253. FIBERBOARD SHEATHING SHALL CONFORM TO ASTM C 208. h.SPACING OF FASTENERS ON FLOOR SHEATHING PANEL EDGES APPLIES TO PANEL EDGE SUPPORTED BY FRAMING MEMBERS AND REQUIRED BLOCKING AND AT FLOOR PERIMETERS ONLY. SPACING OF FASTENERS ON ROOF SHEATHING PANEL EDGES APPLIES TO PANEL EDGES SUPPORTED BY FRAMING MEMBERS AND REQUIRED BLOCKING. BLOCKING OF ROOF AND FLOOR SHEATHING PANEL EDGES PERPENDICULAR TO THE FRAMING MEMBERS NEED NOT BE PROVIDED EXCEPT AS REQUIRED BY OTHER PROVISIONS OF THIS CODE. FLOOR PERIMETER SHALL BE SUPPORTED BY FRAMING MEMBERS OR SOLID BLOCKING. j.WHERE A RAFTER IS FASTENED TO AN ADJACENT PARALLEL CEILING JOIST IN ACCORDANCE WITH THIS SCHEDULE, PROVIDE TWO TOE NAILS ON ONE SIDE OF THE RAFTER AND TOE NAILS FROM THE CEILING JOIST TO TOP PLATE IN ACCORDANCE WITH THIS SCHEDULE. THE TOE NAIL ON THE OPPOSITE SIDE OF THE RAFTER SHALL NOT BE REQUIRED. j.RSRS-01 IS A ROOF SHEATHING RING SHANK NAIL MEETING THE SPECIFICATIONS IN ASTM F1667. ·THE FASTENER SCHEDULE PROVIDES MINIMUM NAILING REQUIREMENTS (I.E. SIZE, SPACING) FOR CONNECTING BUILDING ELEMENTS USED IN WOOD FRAMED CONSTRUCTION. FOR WOOD STRUCTURAL PANELS, BOTH EDGE NAILING AND INTERMEDIATE (FIELD) NAILING ARE SPECIFIED. IN ADDITION TO THE NAILING FOR WOOD STRUCTURAL PANELS, FASTENERS ARE SPECIFIED FOR GYPSUM WALL SHEATHING, CELLULOSIC FIBERBOARD WALL SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENT. GENERAL NOTES 1.BUILDING CODE: 2022 CALIFORNIA BUILDING CODE (C.B.C.) 2022 CALIFORNIA RESIDENTIAL CODE (C.R.C) 2.FLOOR LIVE LOAD = N/A 3.ROOF LOAD: DL = 15 PSF LL = 20 PSF 4.CEILING LOAD:DL = 5 PSF LL = 20 PSF 5.WIND DESIGN DATA: a)BASIC WIND SPEED ...............................................110MPH b)WIND IMPORTANT FACTOR, I ...............................1.0 c)OCCUPANCY CATEGORY......................................II d)WIND EXPOSURE ...................................................C 6.EARTHQUAKE DESIGN DATA: a)SEISMIC IMPORTANT FACTOR, I .........................1.0 b)SEISMIC DESIGN CATEGORY .............................II c)SITE CLASS............................................................D d)Ss.............................................................................1.329 e)S1 ............................................................................0.473 f)SDS...........................................................................1.063 g)SD1 ..........................................................................NULL h)DESIGN BASE SHEAR.............................................6103# i)Cs..............................................................................0.154 j)RESPONSE MODIFICATION FACTOR....................R=6.5 k)REDUNDANCY FACTOR ........................................ρ=1.3 l)ANALYSIS PROCEDURE .......................................Equivalent Lateral Force Procedure USE LIGHT-FRAMED WALLS SHEATHED WITH WOOD STRUCTURAL PANELS RATED FOR SHEAR RESISTANCE OR STEEL SHEETS 7. SOIL REPORT NO : GEO252524LP, DATED: 09/12/2024, BY TMC ENGINEERS INC. STRUCTURAL NOTES AND SPECIFICATIONS FOUNDATION 1.FOUNDATION HAVE BEEN DESIGNED USING ALLOWABLE SOIL BEARING CAPACITY OF 1,500 PSF, 2.FOUNDATION DESIGN SHALL BE 24" MIN. DEPTH OF FTG BELOW LOWEST ADJACENT FINAL GRADE, AND 12" MIN. WIDTH FOR 1 STORY, 15" MIN. WIDTH FOR 2 STORY, BEAR ON FIRM NATIVE OR PROPERLY COMPACTED SOILS. 3.FOUNDATION DESIGN IS BASED ON NON-EXPANSIVE SOIL. IF FOUND THAT SOIL EXPANSIVE SO THAT FOOTINGS ARE REDESIGNED PRIOR TO POURING OF CONCRETE FOUNDATIONS. 4.EXISTING FOUNDATIONS ARE ASSUMED TO BE IN GOOD CONDITION.CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY FOUNDATION WITH SIGNIFICANT SETTLEMENT, SEVERE CRACKING OR ANY INDICATION OF STRUCTURAL FAILURE OR DISTRESS OR DEFECT. 5.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING, FENCE ENCLOSURES AND PROTECTION LIFE AND PROPERTY UNTIL THE PROJECT IS COMPLETE. 6.A DILIGENT SEARCH SHALL BE CONDUCTED BY THE SOIL ENGINEER AND GRADING OR GENERAL CONTRACTOR TO LOCATE CESSPOOLS, SEPTIC TANK ETC, IF FOUND, PROPER ABANDONMENT PROCEDURE SHALL BE CONDUCT AS DIRECTED BY THE SOILS ENGINEER. ABANDONMENT AND/OR COMPACTION REPORT SHALL BE SUBMITTED TO THE CITY BUILDING DEPARTMENT AND ENGINEER REPORT. 7.CONTRACTOR SHALL BRACE OR PROTECT FORM LATERAL LOADS FOR THE PIT AND RETAINING WALLS UNTIL ATTACHING SLABS ARE COMPLETELY IN PLACE AND HAVE ATTAINED FULL STRENGTH. NO VERTICAL EXCAVATIONS 4'-0" OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESEND SHALL BE PERMITTED REINFORCING STEEL 1.REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO THE REQUIREMENTS OF A.S.T.M. A-615 GRADE 60 FOR BARS LARGER THAN #4, GR.40 FOR #4 OR SMALLER. WELDED WIRE FABRIC SHALL CONFORM TO A.S.T.M. A-82 AND A-185 . LAP 12 INCHES MINIMUM. 2.DETAILING, FABRICATION AND ERECTION OF REINFORCING BARS SHALL CONFORM TO THE LATEST EDITION OF A.C.I. 3.MANUAL OF STANDARD PRACTICE FOR DETAILING AND REINFORCED CONCRETE STRUCTURES. 4.MINIMUM COVER FORECAST IN PLACE CONCRETE SHALL BE AS FOLLOWS: a.POURED AGAIN EARTH 3 INCHES b.POURED AGAIN FORM BELOW GRADE 2 INCHES c.FORMED SLABS 3/4 INCH d.SLAB ON GRADE, TOP COVER 1 INCH e.COLUMN AND BEAM MAIN BARS 1-1/2 INCHES f.WALLS EXPOSED TO WEATHER # 6 AND LARGER 2 INCHES g. WALL EXPOSED TO WEATHER # 5 AND SMALLER 1-1/2 INCHES 5.BARS SHALL BE CLEAN OF RUST, GREASE AND OTHER DELETERIOUS MATERIAL THAT MAY AFFECT BOND. 6.ALL BEND SHALL BE MADE COLD. 7.LAP SPLICE LENGTH SHALL BE 42 BARS DIAMETERS MINIMUM AND SHALL BE STAGGERED. 8.DOWELS BETWEEN FOOTING AND WALLS OR COLUMNS SHALL HAVE SAME SIZE AS THE VERTICAL REINFORCEMENT, EMBEDMENT OF DOWELS SHALL BE 36 BAR DIAMETER OR 2'-0" MINIMUM UNLESS OTHERWISE SHOWN. DOWELS SHALL BE EQUAL IN SIZE AND SPACING. 9.FOR STEM WALLS LONGER THAN 24", PROVIDE #4 VERTICAL BARS @ 24" O.C. 10.LANDING - 3 ½" CONC W/ 6X6 10/10 WIRE MESH. 11.PROVIDE VERTICAL AND HORIZONTAL REBAR IN FOUNDATION STEM WALL THAT EXCEEDS 24" IN HEIGHT MEASURED FROM TOP OF FOOTING. 12.MINIMUM LAP OF MESH SHALL BE NOT LESS THAN THE SPACING OF THE CROSS WIRE PLUS TWO INCHES OR 60 DIA, OR 8 IN. WHICHEVER IS GREATER 13.ALL REINFORCING BARS, EMBEDS, ANCHOR BOLTS, HOLDOWNS ETC. SHALL BE SECURED IN PLACE PRIOR TO PLACEMENT OF CONCRETE. 14.CODE REQUIRED INSPECTIONS BY JURISDICTION AUTHORITY SHALL BE MADE AN SIGNED OFF PRIOR TO PLACEMENT OF CONCRETE. FRAMING LUMBER 1.ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR LARCH OF THE FOLLOWING MINIMUM GRADES: a.2X JOIST / RAFTERS NO.2 OR BETTER b.4X POSTS / BEAMS / HEADERS NO.2 OR BETTER c.6X AND 8X POSTS / BEAMS / HEADERS NO.1 OR BETTER d.FLOOR JOIST ABOVE GARAGE TO BE D.F.NO.1 OR BETTER e.STUDS: STUD GRADE (UP TO 9'-0"), NO.2 FOR TALLER THAN 9'-0" f.TOP PLATES & MUD SILLS: CONSTRUCTION GRADE OR BETTER 2.WALL SILLS, NAILERS, AND LEDGERS IN CONTACT WITH CONCRETE: PRESERVATIVE TREATED 3.STRUCTURE PANELS SHALL BE DOUGLAS FIR CONFORMING TO U.S. PRODUCT STANDARD PS-1-95 CD WITH EXTERIOR GLUE, AND SHALL BEAR THE STAMP OF AN APPROVED FABRICATOR. 4.INSTALLATION OF VERTICAL AND HORIZONTAL SHEATHING SHALL FIRST BE APPROVED BY THE INSPECTOR PRIOR TO COVERING. 5.NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY SHOWN ON APPROVED PLANS. 6.MAXIMUM MOISTURE CONTENT OF ALL NUMBER SHALL BE 19%. 7.BOLT HOLES TO BE NOMINAL DIAMETER OF BLOT PLUS 1/16 INCH UNLESS NOTED OTHERWISE. PROVIDE WASHERS UNDER HEAD AN NUTS OF BOLTS AND LAG SCREWS. 8.FRAMING CONNECTION HARDWARE: AS MANUFACTURED BY SIMPSON STRONGTIE CO. OR APPROVED EQUIVALENTS DESIGNATIONS USED. USE NAILS PER ICBO APPROVAL AND AS RECOMMENDED BY SIMPSON FOR EACH DEVICE. 9.THE NUMBER OF NAILS CONNECTING LUMBER SHALL NOT BE LESS THAN THE MINIMUM REQUIRED ON 2022 CRC R602.3(1) 10.ALL NAILS USED ON STRUCTURAL PANELS SHALL BE COMMON NAILS. ALL NAILING TO BE PER CBC 2022 CRC R602.3(1) , UNLESS OTHERWISE NOTED. 11.PROVIDE CONTINUOUS EDGE SUPPORT ALONG TOP AND BOTTOM OF 2X14 JOISTS. 12.BUILT-UP FRAMING MEMBERS SHALL BE CONNECTED AS FOLLOWS: a. 2-2X 16D AT 12" O.C. STAGGERED TOP AND BOTTOM. b. 3-2X 5/8" DIA. M.B. AT 18" O.C. STAGGERED TOP & BOTTOM. c. 4-2X 5/8" DIA. M.B. AT 18" O.C. STAGGERED TOP & BOTTOM. 13.PROVIDE DOUBLE JOISTS UNDER PARALLEL PARTITIONS. 14.PROVIDE SOLID BLOCKING UNDER ALL NON-PARALLEL PARTITIONS. 15.INSTALL LAG BOLTS BY DRILLING LEAD HOLE 65% TO 75% OF SHANK DIAMETER AND FULL DIAMETER FOR SHANK PORTION. 16.USE SOAP OR OTHER APPROVED LUBRICANT ON THREADS. INSTALLATION SHALL BE BY TIGHTENING OF SCREW NOT BY HAMMERING. 17.TRUSS JOISTS SHOP DRAWINGS SHALL BE PROVIDED BY THE SUPPLIER AND SUBMITTED TO THE BUILDING DEPARTMENT FOR APPROVAL PRIOR TO FABRICATION. SHOP DRAWINGS SHALL BE STAMPED AND WET SIGNED BY A LICENSED ENGINEER. STEEL 1.ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL CONFORM TO A.S.T.M. A-36 AND SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE A.I.S.C. SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDING, LATEST EDITION. 2.PIPE COLUMNS SHALL CONFORM TO A.S.T.M. A-53 GRADE B. 3.TUBULAR STEEL SHALL CONFORM TO A.S.T.M. A500 GRADE B. 4.BOLTS SHALL CONFORM TO A.S.T.M. A-307 UNLESS NOTED OTHERWISE. 5.SHOP DRAWING SHALL BE SUBMITTED TO THE ARCHITECT AND ENGINEER AND BUILDING DEPARTMENT FOR REVIEW PRIOR TO FABRICATION. 6.FABRICATION SHALL BE DONE IN THE SHOP OF LICENSED FABRICATORS. 7.USED ELECTRIC ARC PROCESS WELDING WITH E70XX ELECTRODES. 8.ALL WELDING SHALL BE DONE IN THE SHOP OF LICENSED FABRICATOR OR PROVIDE CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR. 9.WHERE A FILLET WELD SYMBOL IS USED IN THE PLANS WITHOUT INDICATION OF SIZE, THE MINIMUM WELD SIZE AS SPECIFIED IN THE A.I.S.C. MANUAL OF STEEL CONSTRUCTION SHALL BE USED. CONCRETE 1.THE MINIMUM COMPRESSIVE STRENGTH OF CONCRETE SHALL BE F'C=2,500 PSI @ 28 DAYS UNLESS OTHERWISE NOTED, WATER_CEMENT RATIO OF 0.45, TYPE V CEMENT. 2.AGGREGATES SHALL CONFORM TO A.S.T.M. C33 3.READY-MIXED CONCRETE SHALL BE IN ACCORDANCE WITH REQUIREMENTS OF ASTM C94. 4.MAXIMUM SLUMP SHALL BE 5" UNLESS NOTED OTHERWISE. 5.CONCRETE SHALL BE MAINTAINED MOIST A MINIMUM OF 10 DAYS AFTER PLACEMENT. 6.PRIOR TO PLACING CONCRETE, REINFORCING STEEL AND EMBEDDED ITEMS SHALL WELL SECURED IN PROPER POSITIONS. 7.USE TYPE II OR V CEMENT AS REQUIRED AGAINST SULFATE ATTACK. 8.ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED. 9.HOLD-DOWNS SHALL BE RE-TIGHTENED JUST PRIOR TO COVER THE WALL FRAMING. 1.ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE 2019 CALIFORNIA BUILDING CODES AND ALL AMENDMENTS AND LOCAL, COUNTY, STATE AND FEDERAL REGULATIONS. 2.THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO BID AND SIGNING OF CONTRACT. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT AND ENGINEER AND BE RESOLVED IN WRITING BEFORE PROCEEDING WITH THE WORK. 3.GENERAL NOTES AND TYPICAL DETAILS SHALL APPLY TO ALL PARTS OF THE JOB EXCEPT WHERE THEY ARE IN CONFLICT WITH DETAILS AND NOTES ON OTHER DOCUMENTS; THE MORE STRICT CONDITION APPLIES SUBJECT TO REVIEW BY THE ENGINEER. 4.ALL INFORMATION SHOWN ON THE PLANS RELATIVE TO EXISTING CONDITION WERE CAREFULLY TAKEN IN THE FIELD BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS ARE IN CONFLICT WITH THE PLANS, THEY SHALL BE REPORTED TO THE ENGINEER SO THAT PROPER CHANGES CAN BE MADE. 5.REQUIRED SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR REVIEW. 6.MODIFICATION OF STRUCTURAL PLANS AND MATERIAL SUBSTITUTIONS SHALL NOT BE DONE WITHOUT WRITTEN APPROVAL OF THE ENGINEER. 7.THE APPROVED PLANS AND SPECIFICATIONS REPRESENT THE FINISH STRUCTURE AND DO NOT INCLUDE THE MOTHODS OF CONSTRUCTION. THE CONTRACTOR SHALL SUPEVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION METHODS, MEANS, TECHINQUES, SEQUENCES AND PROCEDURES INCLUDING BUT NOT LIMITED TO SHORING, INSURANCE, FENCING, CONSTRUCTION CANOPY, SCAFFOLDING ETC. FIELD OBSERVATIONS BY THE ENGINEER SHALL NOT BE CONSIDERD AS INSPECTIONS AS REQUIRED BY THE CODE. 8.REFER TO THE ARCHITECTURAL PLANS FOR DIMENSIONS, OPENINGS, LAYOUT ETC. BAR SIZE MINIMUM EMBEDMENT *REMARKS #3 3 1/2" #4 OR 1/2" Ø 4 1/4" #5 OR 5/8" Ø 5 1/2" #6 OR 3/4" Ø 6 3/4" DESIGN CRITERIA FASTENER NOTES EPOXY ANCHORS 1.EPOXY FOR EPOXY ANCHORS SHALL BE SET-XP BY "SIMPSON STRONG-TIE" (ICC ESR. #2508) 2.ANCHORS USED FOR EPOXY ANCHORS SHALL BE ASTM A-307 THREADED RODS UNO. SIZE AND EMBEDMENT SHALL BE AS INDICATED ON PLANS 3.ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH THE EPOXY MANUFACTURER'S RECOMMENDATIONS AND THE CURRENT ICC REPORT 4.ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH CBC-2011 SECTION 1704 AND IN ACCORDANCE WITH THE SPECIFIC SPECIAL INSPECTION REQUIREMENTS SET FORTH IN THE CORRESPONDING ICC REPORT 5.DRILLED HOLES SHALL BE CLEANED OF DUST AND ANY DEBRIS USING NYLON BRUSH AND COMPRESSED AIR OIL, SCALE, AND RUST SHALL BE REMOVED FROM THREADED RODS PRIOR TO INSTALLATION 6.UNLESS NOTED OTHERWISE IN THE PLANS, EPOXY ANCHORS SHALL HAVE THE FOLLOWING MINIMUM EMBEDMENT. EXPOSED TO WEATHER 1.ALL EXPOSED STEEL MEMBERS SHALL BE COATED WITH A ZINC RICH PRIMER. 2.ALL EXTERIOR HANGERS AND OTHER SIMPSON TYPE PRODUCTS SHALL BE GALVANIZED. 3.ALL PLYWOOD SHALL BE OF AN EXP. 1 GRADE. FRAMING 1.DOUBLE FLOOR JOISTS REQUIRED UNDER PARALLEL BEARING PARTITIONS. 2.APPLY CONT. LINE OF GLUE TO FLOOR PANELS AT ALL JOISTS. 3.BLOCKINGS ARE REQUIRED AT ALL SHEARWALL PANEL EDGES. 4.CONSTRUCT OF PLYWOOD SHEARWALL SHALL BE WITH COMMON NAILS ONLY. 8.POWER DRIVEN PINS ARE NOT PERMITTED AT FOUNDATIONS HORIZONTAL 9.HOLDDOWN BOLT HOLES AT EACH END OF THE PLYWOOD SHEARWALLS SHALL HAVE TOLERANCE OF NO MORE THAN 1/16". 10.ALL POSTS WITH HOLDDOWNS OR UPLIFT STRAPS SHALL HAVE CONTINUOUS EDGE NAILING. 11.ANCHOR BOLTS SHALL BE MIN. 5/8" DIA., 7" EMB. INTO CONCRETE, @ 4' OC U.O.N. ON SHEARWALL SCHEDULE, 12" FROM ENDS, 2 MINIMUM PER PLATE, AND WITH 3"X3"X.229" STEEL PLATE WASHERS. BOLTS SHALL EXTEND 5" INTO FOOTING ON TWO POUR SYSTEM (EXTRA LONG BOLTS). PROVIDE MINIMUM EDGE DISTANCE OF 1 7/8" FOR THE 5/8" DIA. ANCHOR BOLTS. 12.PLATE WASHERS FOR ALL ANCHOR BOLTS TYPICAL: PLYWOOD SHEATHING: 1.SLOPED/FLAT NON-ASSEMBLY ROOF SHEATHING: 15/32" APA RATED SHEATHING EXP 1 WITH A MIN. PANEL INDEX OF 32/16. REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE. ROOF SHEATHING RING SHANK #03 (2 1/2" X 0.131") NAIL @ 6" O.C. @ PANEL EDGES & 12" O.C. @ INTERMEDIATE. 2.FLOOR/ROOF DECK/DECK SHEATHING: 23/32" APA RATED STURD-I-FLOOR T&G EXP I WITH MIN. SPAN RATING OF 24" O.C. REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE. T&G OR BLOCKING REQUIRED ALL EDGES, 10D @ 6" @ PANEL EDGES & 12" @ INTERMEDIATE. 3.VERTICAL PLYWOOD SHEATHING: SEE SHEAR WALL SCHEDULE. 4.ALL STRUCTURAL RATED PANELS MUST BE STAMPED BY ONE OF THE FOLLOWING APPROVED AGENCIES, APA, PFS/TECO OR PITTSBURG. 5.USE RING OR SCREW SHANK NAILS AND GLUE SHEATHING TO FRAMING USING ADHESIVES MEETING APA SPECIFICATION AFG-01 OR ASTM D3498. APPLY GLUE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 6.AS AN ALTERNATE TO 10D COMMON NAILS, THE FOLLOWING FASTNERS CAN BE USED: GRABBER PLYWOOD SCREWS (ICC-ER-5280), OR SIMPSON STRONG-TIE QUICK DRIVE SCREWS (ICC-ER-1472), MIN 2" LONG @ 6" O.C. B.S., @ 6" O.C. E.S. AND 12" O.C. F.S. GLULAM/PARALLAM/MICROLAM BEAMS 1.GLUE LAMINATED BEAM S SHALL BE PER AMERICAN INSTITUTE OF TIMBER CONSTRUCTION 117. CONBINATION SYMBOLS SHALL BE AS FOLLOWS: a)24F-V4 DF/DF FOR SIMPLE BEAMS b)24F-V8 DF/DF FOR CANTILEVERED BEAMS 2.PARALLAM BEAMS SHALL BE 2.0E PSL, ICC # ESR-1387 3.MICROLAM BEAMS SHALL BE 2.0E LVL 4.LAMINATED BEAMS SHALL BE FABRICATED BY A LICENSED FABRICATOR AND SHALL BE ACCOMPANIED TO THE JOB SITE WITH CERTIFICATE OF FABRICATION. BOLT SIZE (A307)PLATE SIZE (ASTMA-36)MIN. EDGE DISTANCE (IN.) 5/8" Ø 0.229" x 3" x 3"1 7 8 3/4" Ø 0.229" x 3" x 3"2 1 2 7/8" Ø 5/16" x 3" x 3"2 5 8 1 1/4" Ø 3/8" x 3 1/2" x 3 1/2"3 3 4 SHEET INDEX DEFERRED SUBMITTAL Consultant: Address: Address Phone e-mail AD D R E S S : SHEET NAME DATE DRAWN BY: CHECKED BY: SHEET NUMBER REVISION STAMP PR O J E C T 12 / 8 / 2 0 2 4 NE W D E T A C H E D A D U LP 12/08/2024 HP 2 7 2 6 S T R A W B E R R Y L A N E , U N I T 2 Description Date SA N T A A N A , C A 9 2 7 0 6 2 7 2 6 S T R A W B E R R Y L A N E SA N T A A N A , C A 9 2 7 0 6 1ST PC RESPONSE 12/08/241 GENERAL NOTES AND REQUIREMENT SN1 (4) (2) (1) (3) 870 (PLF) SHEAR ALLOWABLE 220 2022 CALIFORNIA BUILDING CODE (1), (3) SHEAR WALL SCHEDULE PANEL TYPE SHEAR 8 d's 10 d's @ 2" O.C. 8 d's @ 2" O.C. @ 3" O.C. 15/32" APA Structural I rated 3/8" APA rated 10 d's @ 12" O.C. 8 d's @ 12" O.C. 8 d's @ 12" O.C. 8 d's @ 4" O.C. NAILING (COMMON) EDGE 8 d's @ 6" O.C. 3/8" APA rated rated 3/8" APA SHEATHING 8 d's @ 12" O.C. @ 12" O.C. 8 d's FIELD (COMMON) NAILING STUDS ARE SPACED @ 16" O.C. MAX. UNLESS NOTED OTHERWISE ON PLAN. PERIODIC SPECIAL INSPECTION IS REQUIRED. (4) (2) 3 2 1 4 5 (5) (6) USE CLIPS @ 6" O.C. ON SIMPSON STRONG WALL & HARDY FRAME (U.N.O.). @ 4" O.C. @ 6" O.C. @ 3" O.C. @ 2" O.C. @ 16" O.C. @ 12" O.C. @ 8" O.C. @ 6" O.C. @ 5" O.C. @ 24" O.C. @ 16" O.C. @ 12" O.C. @ 10" O.C. @ 6" O.C. SHEATHING PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED IN ALL CASES. PROVIDE 3" NOMINAL OR WIDER FRAMING AT ADJOINING PANEL EDGES WITH NAILS STAGGERED. USE SPACING PER SCHEDULE IF NUMBER OF FRAMING CLIPS ARE NOT SPECIFIED ON FRAMING PLANS. FRAMING CLIPS A35's, LS50's OR LTP5's (5), (6) 2 ROWS STAGG. @ 3" O.C. (4) (2) (4) (2) (4) (2) (8) 260 320 380 410 490 (7)ALLOWABLE SHEAR ARE FOR STUDS SPACED @ 24" O.C. MAX. (8)SHEATHING CONFORMS TO EITHER DOC PS 1 OR PS 2 STANDARDS. (9)NAILING @ 6" O.C. WHEN STUDS ARE SPACED @ 24" O.C. (9) (7) (7) (7) 3/8" APA rated 530 640 (7) (10)FOR DOUBLE SIDED SHEAR PANELS: (10)(10)(10) (10)(10)(10) (10)(10)(10) a. USE HALF THE SPACING OF SILL PLATE FASTENERS STAGGERED FOR TYPE . b. USE ONLY 1/4"Øx6" SDS SCREWS IN SCHEDULE AND WITH HALF THE SPACING, FOR TYPES & . 3 4 5 c. SEE SHEAR TRANSFER DETAIL ON PLAN FOR FRAMING CLIP TYPES AND SPACING, FOR TYPES , & .3 4 5 SILL PLATE CONNECTION SINKER 16d's SCREWS RIM BOARD LSL & DF 1/4"Øx6" SDS SCREWS RIM BOARD LVL 1/4"Øx6" SDS @ 14" O.C. @ 10" O.C. @ 7" O.C. @ 5" O.C. @ 4" O.C. (10) (10) (10) PRESCRIPTIVE TABLES JOIST SPACING ATTICS WITHOUT STORAGE, LL=10PSF ATTICS WITH STORAGE, LL=20PSF 2X4 2X6 2X8 2X10 2X4 2X6 2X8 2X10 12"12'-5"19'-6"25'-8"--9'-10"14'-10"18'-9"22'-11" 16"11'-3"17'-8"23'-4"--8'-11"13'-0"16'-6"20'-2" 24"9'-10"15'-0"19'-1"23'-3"7'-3"10'-8"13'-6"16'-5" DF #2 CEILING JOISTS, ALLOWABLE SPANS DATA FROM CRC TABLE R802.5.1(1) & R802.5.1(2) ATTIC WITH STORAGE ARE THOSE WHERE THE CLEAR HEIGHT BETWEEN THE CEILING JOIST AND RAFTER IS 42" OR GREATER. ATTICS SHALL BE UNINHABITABLE. CEILING DEAD LOAD SHALL NOT EXCEED 5 PSF. TIE SPACING ROOF PITCH 3:12 4:12 5:12 7:12 9:12 SPAN SPAN SPAN SPAN SPAN 12'20'28'36'12'20'28'36'12'20'28'36'12'20'28'36'12'20'28'36' 12"4 6 8 1 3 5 6 8 3 4 5 6 3 4 4 5 3 3 4 4 16"5 8 10 13 4 6 8 10 3 5 6 8 3 4 5 6 3 4 4 5 24"7 11 15 19 5 8 12 15 4 7 9 12 3 5 7 9 3 4 6 7 RAFTER TIE CONNECTIONS, #16d COMMON NAILS DATA FROM CRC TABLE R802.5.2 VALUES ADJUSTED FOR DF#2 FRAMING. THE NUMBER OF NAILS SPECIFIED IN THE TABLE SHALL BE PROVIDED AT EACH CONNECTION. WHEN FULL-HEIGHT INTERIOR BEARING WALLS OR PURLIN BRACING ARE PROVIDED, RAFTER TIE NAILING MAY BE REDUCED PROPORTIONAL TO THE REDUCTION IN RAFTER SPAN; NO LESS THAN 3 NAILS SHALL BE PROVIDED AT EACH CONNECTION. NO SNOW LOAD JOIST SPACING DL = 10PSF, LL = 40PSF 2X6 2X8 2X10 2X12 12"10'-9"14'-2"18'-0"20'-11" 16"9'-9"12'-9"15'-7"18'-1" 24"8'-3"10'-5"12'-9"14'-9" DF #2 FLOOR JOISTS, ALLOWABLE SPANS DATA FROM CRC TABLE R502.3.1(2) SHEATHING GRADE ALLOWABLE LL(PSF)ROOF FLOOR SPAN RATING FLOOR/R OOF SPAN THICKNE SS SPAN @16"O.C. SPAN @24"'O.C. MAX. SPAN (in.)LOADS (psf) PANEL EDGES WITH T&G JOINTS OR BLOCKING MAX. SPAN (in.) WITH EDGE SUPPOR T WITHOUT EDGE SUPPOR T TOTAL LOAD LIVE LOAD 24 0 3 8 100 30 24 20 40 30 0 24 16 7 16 100 40 24 24 50 40 16 32 16 15 32 180 70 32 28 40 30 16 40 20 19 32, 5 8 305 130 40 32 40 30 20 48 24 3/4, 3/4, 0 -175 48 36 45 35 24 PLYWOOD OR OSB FLOOR AND ROOF SHEATHING, ALLOWABLE SPANS DATA FROM CRC TABLE R503.2.1.1(1) SHEATHING PANELS SHALL BE CONTINUOUS OVER TWO OR MORE SPANS AND PERPENDICULAR TO SUPPORTS. FOR 1/2" SHEATHING MAXIMUM SPAN SHALL BE 24". EDGE SUPPORT MAY BE PROVIDED BY TONGUE AND GROOVE EDGES, 2X BLOCKING OR PANEL EDGE CLIPS. SIGNED DATE: 12/8/2024 1 2726 W Strawberry Ln & Unit# 23/17/2025 TABLE - MAXIMUM FIXTURE WATER USE FIXTURE TYPE FLOW RATE (RESIDENTIAL) SHOWER HEADS 2.0 GMP @ 80 PSI (RESIDENTIAL) LAVATORY FAUCETS MIN. 0.8 GPM @ 20 PSI MAX. 1.2 GPM @ 60 PSI COMMON & PUBLIC USE AREAS LAVATORY FAUCETS IN 0.5 GPM @ 60 PSI KITCHEN FAUCETS 1.8 GPM @ 60 PSI METERING FAUCETS 0.25 GAL/CYCLE WATER CLOSET 1.28 GAL/FLUSH URINALS 0.125 GAL/FLUSH 1,2TABLE 4.504.1 - ADHESIVE VOC LIMIT (Less Water and Less Exempt Compounds in Grams per Liter) ARCHITECTURAL APPLICATIONS CURRENT VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT & ASPHALT TILE ADHESIVES 50 DRYWALL & PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVE 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP & TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD)50 WOOD 30 FIBERGLASS 80 THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, QUALITY MANAGEMENT DISTRICT RULE 1168. THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE RESIDENTIAL MANDATORY MEASURES CHAPTER 4 PLANNING AND DESIGNDIVISION 4.1 Commission will continue to adopt mandatory standards. For the purposes of mandatory energy efficiency standards in this code, the California Energy 4.201.1 SCOPE. 4.201 GENERAL ENERGY EFFICIENCYDIVISION 4.2 WATER EFFICIENCY AND CONSERVATIONDIVISION 4.3 ordinance, if more restrictive. corrugated cardboard, glass, plastics, organic waster, and metals, or meet a lawfully enacted local recycling depositing, storage and collection of non-hazaradous materials for recycling, including (at a minimum) paper, building site, provide readily accessible area(s) that serves all buildings on the site and is identified for the Where 5 or more multifamily dwelling units are constructed on a 4.410.2 RECYCLING BY OCCUPANTS. ] code. Green Building Standards California 10. A copy of all special inspections verifications required by the enforcing agency or this [ 9. Information about state solar energy and incentive programs available. painting, grading around the building, etc. 8. Information on required routine maintenance measures, including, but not limited to, caulking, feet away from the foundation. 7. Instructions for maintaining gutters and downspouts and the importance of diverting water at least 5 water. 6. Information about water-conserving landscape and irrigation design and controllers which conserve and what methods an occupant may use to maintain the relative humidity level in that range. 5. Educational material on the positive impacts of an interior relative humidity between 30-60 percent 4. Public transportation and/or carpool options available in the area. resource consumption, including recycle programs and locations. 3. Information from local utility, water and waste recovery providers on methods to further reduce e. Water reuse systems. d. Landscape irrigation systems. c. Space conditioning systems, including condensers and air filters. b. Roof and yard drainage, including gutters and downspouts. appliances and equipment. photovoltaic systems, electric vehicle chargers, water-heating systems and other major a. Equipment and appliances, including water-saving devices and systems, HVAC systems, 2. Operation and maintenance instructions for the following: life cycle of the structure. 1. Directions to the owner or occupant that the manual shall remain with the building throughout the following shall be placed in the building: disc, web-based reference or other media acceptable to the enforcing agency which includes all of the At the time of final inspection, a manual, compact 4.410.1 OPERATION AND MAINTENANCE MANUAL. 4.410 BUILDING MAINTENANCE AND OPERATION Department of Resources Recycling and Recovery (CalRecycle). 2. Mixed construction and demolition debris (C & D) processors can be located at the California documenting compliance with this section. (Residential)" located at www.hcd.ca.gov/CALGreen.html may be used to assist in 1. Sample forms found in "A Guide to the California Green Building Standards Code :Notes compliance with Section 4.408.2, items 1 through 5, Section 4.408.3 or Section 4.408.4.. . Documentation shall be provided to the enforcing agency which demonstrates 4.408.5 DOCUMENTATION in Section 4.408.1 lbs./sq.ft. of the building area, shall meet the minimum 65% construction waste reduction requirement weight of construction and demolition waste disposed of in landfills, which do not exceed 2 Projects that generate a total combined 4.408.4.1 WASTE STREAM REDUCTION ALTERNATIVE. Section 4.408.1 lbs./sq.ft. of the building area shall meet the minimum 65% construction waste reduction requirement in weight of construction and demolition waste disposed of in landfills, which do not exceed 3.4 Projects that generate a total combined 4.408.4 WASTE STREAM REDUCTION ALTERNATIVE [LR]. materials will be diverted by a waste management company. The owner or contractor may make the determination if the construction and demolition waste Note: demolition waste material diverted from the landfill complies with Section 4.408.1. enforcing agency, which can provide verifiable documentation that the percentage of construction and Utilize a waste management company, approved by the 4.408.3 WASTE MANAGEMENT COMPANY. by weight or volume, but not by both. 5. Specify that the amount of construction and demolition waste materials diverted shall be calculated generated. 4. Identify construction methods employed to reduce the amount of construction and demolition waste taken. 3. Identify diversion facilities where the construction and demolition waste material collected will be bulk mixed (single stream). 2. Specify if construction and demolition waste materials will be sorted on-site (source separated) or reuse on the project or salvage for future use or sale. 1. Identify the construction and demolition waste materials to be diverted from disposal by recycling, necessary and shall be available during construction for examination by the enforcing agency. in conformance with Items 1 through 5. The construction waste management plan shall be updated as . Submit a construction waste management plan 4.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN jobsite are located in areas beyond the haul boundaries of the diversion facility. 3. The enforcing agency may make exceptions to the requirements of this section when isolated close to the jobsite. recycle facilities capable of compliance with this item do not exist or are not located reasonably 2. Alternate waste reduction methods developed by working with local agencies if diversion or 1. Excavated soil and land-clearing debris. Exceptions: management ordinance. 4.408.2, 4.408.3 or 4.408.4, or meet a more stringent local construction and demolition waste percent of the non-hazardous construction and demolition waste in accordance with either Section Recycle and/or salvage for reuse a minimum of 65 4.408.1 CONSTRUCTION WASTE MANAGEMENT. 4.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING agency. openings with cement mortar, concrete masonry or a similar method acceptable to the enforcing sole/bottom plates at exterior walls shall be protected against the passage of rodents by closing such Annular spaces around pipes, electric cables, conduits or other openings in 4.406.1 RODENT PROOFING. 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE EFFICIENCY MATERIAL CONSERVATION AND RESOURCE DIVISION 4.4 2. Field verification of on-site product containers. 1. Manufacturer's product specification. enforcing agency. Documentation may include, but is not limited to, the following: Verification of compliance with this section shall be provided at the request of the 4.504.2.4 Verification. 8, Rule 49. Quality Management District additionally comply with the percent VOC by weight of product limits of Regulation , Title 17, commencing with Section 94520; and in areas under the jurisdiction of the Bay Area Air Regulations California Code of compounds and ozone depleting substances, in Sections 94522(e)(1) and (f)(1) of Limits for ROC in Section 94522(a)(2) and other requirements, including prohibitions on use of certain toxic Aerosol paints and coatings shall meet the Product-weighted MIR 4.504.2.3 Aerosol Paints and Coatings. Table 4.504.3 shall apply. Board, Suggested Control Measure, and the corresponding Flat, Nonflat or Nonflat-High Gloss VOC limit in coating, based on its gloss, as defined in subsections 4.21, 4.36, and 4.37 of the 2007 California Air Resources listed in Table 4.504.3 shall be determined by classifying the coating as a Flat, Nonflat or Nonflat-High Gloss apply. The VOC content limit for coatings that do not meet the definitions for the specialty coatings categories the ARB Architectural Suggested Control Measure, as shown in Table 4.504.3, unless more stringent local limits Architectural paints and coatings shall comply with VOC limits in Table 1 of 4.504.2.2 Paints and Coatings. commencing with section 94507. , Title 17, California Code of Regulations prohibitions on use of certain toxic compounds, of than 16 fluid ounces) shall comply with statewide VOC standards and other requirements, including units of product, less packaging, which do not weigh more than 1 pound and do not consist of more 2. Aerosol adhesives, and smaller unit sizes of adhesives, and sealant or caulking compounds (in tricloroethylene), except for aerosol products, as specified in Subsection 2 below. compounds (chloroform, ethylene dichloride, methylene chloride, perchloroethylene and Such products also shall comply with the Rule 1168 prohibition on the use of certain toxic applicable or SCAQMD Rule 1168 VOC limits, as shown in Table 4.504.1 or 4.504.2, as applicable. shall comply with local or regional air pollution control or air quality management district rules where 1. Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant primers and caulks management district rules apply: requirements of the following standards unless more stringent local or regional air pollution or air quality Adhesives, sealant and caulks used on the project shall meet the 4.504.2.1 Adhesives, Sealants and Caulks. Finish materials shall comply with this section.4.504.2 FINISH MATERIAL POLLUTANT CONTROL. to reduce the amount of water, dust or debris which may enter the system. openings shall be covered with tape, plastic, sheet metal or other methods acceptable to the enforcing agency startup of the heating, cooling and ventilating equipment, all duct and other related air distribution component At the time of rough installation, during storage on the construction site and until final CONSTRUCTION. 4.504.1 COVERING OF DUCT OPENINGS & PROTECTION OF MECHANICAL EQUIPMENT DURING 4.504 POLLUTANT CONTROL pellet stoves and fireplaces shall also comply with applicable local ordinances. applicable, and shall have a permanent label indication they are certified to meet the emission limts. Woodstoves, woodstove or pellet stove shall comply with U.S. EPA New Source Performance Standards (NSPS) emission limits as . Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed 4.503.1 GENERAL 4.503 FIREPLACES hydrogen and may contain oxygen, nitrogen and other elements. See CCR Title 17, Section 94508(a). with vapor pressures greater than 0.1 millimeters of mercury at room temperature. These compounds typically contain A volatile organic compound (VOC) broadly defined as a chemical compound based on carbon chains or rings VOC. ozone formation in the troposphere. Any compound that has the potential, once emitted, to contribute to REACTIVE ORGANIC COMPOUND (ROC). Note: PWMIR is calculated according to equations found in CCR, Title 17, Section 94521 (a). product (excluding container and packaging). article. The PWMIR is the total product reactivity expressed to hundredths of a gram of ozone formed per gram of The sum of all weighted-MIR for all ingredients in a product subject to this PRODUCT-WEIGHTED MIR (PWMIR). The weight of the water in wood expressed in percentage of the weight of the oven-dry wood.MOISTURE CONTENT. and 94701. Note: MIR values for individual compounds and hydrocarbon solvents are specified in CCR, Title 17, Sections 94700 /g ROC). ³hundredths of a gram (g O compound to the "Base Reactive Organic Gas (ROG) Mixture" per weight of compound added, expressed to The maximum change in weight of ozone formed by adding a MAXIMUM INCREMENTAL REACTIVITY (MIR). ENVIRONMENTAL QUALITYDIVISION 4.5 1701.1 of the California Plumbing Code. in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table Plumbing fixtures and fittings shall be installed 4.303.2 STANDARDS FOR PLUMBING FIXTURES AND FITTINGS. reduction. : Where complying faucets are unavailable, aerators or other means may be used to achieve Note minute at 60 psi. to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons 4.303.1.4.4 Kitchen Faucets. more than 0.25 gallons per cycle. Metering faucets when installed in residential buildings shall not deliver 4.303.1.4.3 Metering Faucets. buildings shall not exceed 0.5 gallons per minute at 60 psi. faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential The maximum flow rate of lavatory 4.303.1.4.2 Lavatory Faucets in Common and Public Use Areas. not be less than 0.8 gallons per minute at 20 psi. not exceed 1.2 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall The maximum flow rate of residential lavatory faucets shall 4.303.1.4.1 Residential Lavatory Faucets. 4.303.1.4 Faucets. : A hand-held shower shall be considered a showerhead.Note allow one shower outlet to be in operation at a time. a single valve shall not exceed 2.0 gallons per minute at 80 psi, or the shower shall be designed to only showerhead, the combined flow rate of all the showerheads and/or other shower outlets controlled by . When a shower is served by more than one 4.303.1.3.2 Multiple showerheads serving one shower WaterSense Specification for Showerheads. gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA Showerheads shall have a maximum flow rate of not more than 2.0 4.303.1.3.1 Single Showerhead. 4.303.1.3 Showerheads. The effective flush volume of all other urinals shall not exceed 0.5 gallons per flush. The effective flush volume of wall mounted urinals shall not exceed 0.125 gallons per flush. 4.303.1.2 Urinals. of two reduced flushes and one full flush. : The effective flush volume of dual flush toilets is defined as the composite, average flush volume Note Specification for Tank-type Toilets. flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense The effective flush volume of all water closets shall not exceed 1.28 gallons per 4.303.1.1 Water Closets. urinals) and fittings (faucets and showerheads) shall comply with the following: Plumbing fixtures (water closets and 4.303.1 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. INDOOR WATER USE4.303 SIGNOFF INSPECTOR SIGNOFF INSPECTOR SIGNOFF INSPECTOR SIGNOFF INSPECTOR Irrigation Association. : More information regarding irrigation controller function and specifications is available from the Note controller(s). Soil moisture-based controllers are not required to have rain sensor input. rainfall shall have a separate wired or wireless rain sensor which connects or communicates with the 2. Weather-based controllers without integral rain sensors or communication systems that account for local response to changes in plants' needs as weather conditions change. 1. Controllers shall be weather- or soil moisture-based controllers that automatically adjust irrigation in builder and installed at the time of final inspection shall comply with the following: . Automatic irrigation system controllers for landscaping provided by the 4.304.1 IRRIGATION CONTROLLERS 4.304 OUTDOOR WATER USE NewN Additions and AlterationsAA High RiseHR Low RiseLR Office of Statewide Health Planning and DevelopmentOSHPD Division of the State Architect, Structural SafetyDSA-SS California Building Standards CommissionBSC Department of Housing and Community DevelopmentHCD ABBREVIATION DEFINITIONS: IS INCLUDED AS A CONVENIENCE FOR THE USER. THIS TABLE COMPILES THE DATA IN SECTION 4.303.1, AND NOTE: Chapter 2, to the building. Code, California Building 2. The EV space shall be located on an accessible route, as defined in the from the accessible parking space. Chapter 11A, to allow use of the EV charger California Building Code, requirements of the 1. The EV space shall be located adjacent to an accessible parking space meeting the least one of the following options: When EV chargers are installed, EV spaces required by Section 4.106.2.2, Item 3, shall comply with at areas and available for use by all residents. indicate the location of proposed EV spaces. At least one EV space shall be located in common use Construction documents shall 4.106.4.2.1 Electric vehicle charging space (EV space) locations. EV chargers are installed for use. facilitating future EV charging. There is no requirement for EV spaces to be constructed or available until Construction documents are intended to demonstrate the project's capability and capacity for Note: Calculations for the number of EV spaces shall be rounded up to the nearest whole number. case less than one, shall be electric vehicle charging stations (EV spaces) capable of supporting future EVSE. building site, 3 percent of the total number of parking spaces provided for all types of parking facilities, but in no Where 17 or more multifamily dwelling units are constructed on a 4.106.4.2 New multifamily dwellings. location shall be permanently and visibly marked as "EV CAPABLE". protective device space(s) reserved for future EV charging as "EV CAPABLE". The raceway termination The service panel or subpanel circuit directory shall identify the overcurrent 4.106.4.1.1 Identification. protective device. minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent concealed areas and spaces. The service panel and/or subpanel shall provide capacity to install a 40-ampere proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main dwelling unit, install a listed raceway to accommodate a dedicated 208/240-volt branch circuit. The raceway For each 4.106.4.1 New one- and two-family dwellings and townhouses with attached private garages. to the homeowner or developer by more than $400.00 per unit. infrastructure design requirements on the utility side of the meter so as to increase the utility side cost 2. Where there is evidence substantiating that meeting the requirements will alter the local utility 1. Where there is no commercial power supply. and infrastructure are not feasible based upon one or more of the following conditions: On a case-by-case basis, where the local enforcing agency has determined EV charging Exceptions: . Article 625California Electrical Code,(EVSE) shall be installed in accordance with the 4.106.4.1 and 4.106.4.2 to facilitate future installation and use of EV chargers. Electric vehicle supply equipment New construction shall comply with Sections 4.106.4 Electric vehicle (EV) charging for new construction. : Additions and alterations not altering the drainage path.Exception recharge. 5. Other water measures which keep surface water away from buildings and aid in groundwater 4. Water retention gardens 3. French drains 2. Water collection and disposal systems 1. Swales water include, but are not limited to, the following: manage all surface water flows to keep water from entering buildings. Examples of methods to manage surface Construction plans shall indicate how the site grading or drainage system will 4.106.3 GRADING AND PAVING. 3. Compliance with a lawfully enacted storm water management ordinance. by the enforcing agency. disposal method, water shall be filtered by use of a barrier system, wattle or other method approved 2. Where storm water is conveyed to a public drainage system, collection point, gutter or similar 1. Retention basins of sufficient size shall be utilized to retain storm water on the site. property, prevent erosion and retain soil runoff on the site. during construction, one or more of the following measures shall be implemented to prevent flooding of adjacent or more, shall manage storm water drainage during construction. In order to manage storm water drainage than one acre of soil and are not part of a larger common plan of development which in total disturbs one acre Projects which disturb less 4.106.2 STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION. management of storm water drainage and erosion controls shall comply with this section. and careful planning to minimize negative effects on the site and adjacent areas. Preservation of slopes, Preservation and use of available natural resources shall be accomplished through evaluation 4.106.1 GENERAL. 4.106 SITE DEVELOPMENT used for perimeter and inlet controls. such as hay, straw or similar material shaped in the form of tubes and placed on a downflow slope. Wattles are also Wattles are used to reduce sediment in runoff. Wattles are often constructed of natural plant materials WATTLES. pervious material used to collect or channel drainage or runoff water. A trench, hole or other depressed area loosely filled with rock, gravel, fragments of brick or similar FRENCH DRAIN. (and are included here for reference)The following terms are defined in Chapter 2 4.102.1 DEFINITIONS SECTION 4.102 DEFINITIONS shall comply with the specific green building measures applicable to each specific occupancy. In mixed occupancy buildings, each portion of a building 302.1 MIXED OCCUPANCY BUILDINGS. SECTION 302 MIXED OCCUPANCY BUILDINGS high-rise buildings, no banner will be used. specifically to low-rise only (LR) or high-rise only (HR). When the section applies to both low-rise and buildings, or both. Individual sections will be designated by banners to indicate where the section applies individual sections of CALGreen may apply to either low-rise residential buildings high-rise residential The provisions of 301.2 LOW-RISE AND HIGH-RISE RESIDENTIAL BUILDINGS. [HCD] other important enactment dates. et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and of occupancy or final permit approval by the local building department. See Civil Code Section 1101.1, Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate improvements shall replace noncompliant plumbing fixtures with water-conserving plumbing fixtures. On and after January 1, 2014, residential buildings undergoing permitted alterations, additions, or Note: specific area of the addition or alteration. building's conditioned area, volume, or size. The requirements shall apply only to and/or within the additions or alterations of existing residential buildings where the addition or alteration increases the The mandatory provisions of Chapter 4 shall be applied to 301.1.1 Additions and alterations. [HCD] but are not required unless adopted by a city, county, or city and county as specified in Section 101.7. application checklists and may be included in the design and construction of structures covered by this code, the application checklists contained in this code. Voluntary green building measures are also included in the Buildings shall be designed to include the green building measures specified as mandatory in 301.1 SCOPE. SECTION 301 GENERAL GREEN BUILDING CHAPTER 3 Website: http://opr.ca.gov/docs/ZEV_Guidebook.pdf. governments, residents and businesses. Vehicle Community Readiness Guidebook" which provides helpful information for local 3. The Governor's Office of Planning and Research (OPR) published a "Zero-Emission facilities and for use of EV charging spaces. 2. See Vehicle Code Section 22511 for EV charging space signage in off-street parking Number 13-01. Website: www.dot.ca.gov/trafficops/policy/13-01.pdf Vehicle Signs and Pavement Markings can be found in the New Policies & Directives and specifications for all official traffic control devices in California. Zero Emission on Uniform Traffic Control Devices (California MUTCD)" to provide uniform standards 1. The California Department of Transportation adopts and publishes the "Californa Manual Notes: California Electrical Code.with the protective device space(s) reserved for future EV charging purposes as "EV CAPABLE" in accordance The service panel or subpanel circuit directory shall identify the overcurrent 4.106.4.2.5 Indentification. original construction. underground, enclosed, inaccessible or in concealed areas and spaces shall be installed at the time of 40-ampere minimum branch circuit. Raceways and related components that are planned to be installed at the full rated amperage of the EVSE. Plan design shall be based upon a at all required EV spaces including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs electrical load calculations to verify that the electrical panel service capacity and electrical system, shall also provide information on amperage of future EVSE, raceway method(s), wiring schematics and termination point and proposed location of future EV spaces and EV chargers. Construction documents Construction documents shall indicate the raceway 4.106.4.2.4 Multiple EV spaces required. installation of a branch circuit overcurrent protective device. capacity to install a 40-ampere minimum dedicated branch circuit and space(s) reserved to permit documents shall identify the raceway termination point. The service panel and/or subpanel shall provide cabinet, box or enclosure in close proximity to the proposed location of the EV spaces. Construction diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed volt dedicated branch circuit. The raceway shall not be less than trade size 1 (nominal 1-inch inside Install a listed raceway capable of accommodating a 208/240- 4.106.4.2.3 Single EV space required. horizontal (2.083 percent slope) in any direction. a. Surface slope for this EV space and the aisle shall not exceed 1 unit vertical in 48 units EV space is 12 feet (3658 mm). minimum width of the wide minimum aisle. A 5-foot (1524 mm) wide minimum aisle shall be permitted provided the 3. One in every 25 EV spaces, but not less than one EV space, shall have an 8-foot (2438 mm) 2. The minimum width of each EV space shall be 9 feet (2743 mm). 1. The minimum length of each EV space shall be 18 feet (5486 mm). designed to comply with the following: The EV space shall be4.106.4.2.2 Electric vehicle charging space (EV space) dimensions. combustion from the outside atmosphere and discharges all flue gases to the outside atmosphere. A fuel-burning appliance with a sealed combustion system that draws all air for DIRECT-VENT APPLIANCE. 93120.1. wood I-joists or finger-jointed lumber, all as specified in California Code of regulations (CCR), title 17, Section structural panels, structural composite lumber, oriented strand board, glued laminated timber, prefabricated medium density fiberboard. "Composite wood products" does not include hardboard, structural plywood, Composite wood products include hardwood plywood, particleboard and COMPOSITE WOOD PRODUCTS. cores, not including furniture, fixtures and equipment (FF&E) not considered base building elements. Agrifiber products include wheatboard, strawboard, panel substrates and door AGRIFIBER PRODUCTS. (and are included here for reference)The following terms are defined in Chapter 2 5.102.1 DEFINITIONS SECTION 4.502 DEFINITIONS irritating and/or harmful to the comfort and well being of a building's installers, occupants and neighbors. The provisions of this chapter shall outline means of reducing the quality of air contaminants that are odorous, 4.501.1 Scope SECTION 4.501 GENERAL AS SHOWN OF SHEETS No. Exp. CIVIL RE G ISTERED PROFESSIONAL ENG INE ER STATE OF CALIFORNIA MINH V. TRAN 65250 9-30-25 M INH V. TRAN 18891 SAN CARLO S ST. FO UNTAIN VALLEY CA 92708 714-726-5175 m inhvantran10@ yahoo.com RESIDENTIAL MANDATORY MEASURES, SHEET 1 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 1 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 9/26/2024 T-1.2 Compliance Cal Green JOB SHEET DRAWN DATE SCALE DESCRIPTION DESIGN ADDRESS: SANTA ANA, CA 92706 2726 STRAW BERRY LANE, UNIT 2 NEW DETACHED A.D.U. PRO JECT: SANTA ANA, CA 92706 2726 STRAW BERRY LANE 1 2 REVISIONS BY 2 2726 W Strawberry Ln & Unit# 23/17/2025 TABLE 4.504.2 - SEALANT VOC LIMIT (Less Water and Less Exempt Compounds in Grams per Liter) SEALANTS CURRENT VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NON-POROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 1TABLE 4.504.5 - FORMALDEHYDE LIMITS MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 2THIN MEDIUM DENSITY FIBERBOARD 0.13 93120.12. CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIF. MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE BY THE CALIF. AIR RESOURCES BOARD, AIR TOXICS CONTROL 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED THICKNESS OF 5/16" (8 MM). 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM 2,3ARCHITECTURAL COATINGS TABLE 4.504.3 - VOC CONTENT LIMITS FOR COMPOUNDS GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COATING CATEGORY CURRENT VOC LIMIT FLAT COATINGS 50 NON-FLAT COATINGS 100 NONFLAT-HIGH GLOSS COATINGS 150 SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS)500 HIGH TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 1LOW SOLIDS COATINGS 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS, & UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS CLEAR 730 OPAQUE 550 UNDERCOATERS SPECIALTY PRIMERS, SEALERS & 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB & TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 EXEMPT COMPOUNDS 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE. 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS AVAILABLE FROM THE AIR RESOURCES BOARD. SUGGESTED CONTROL MEASURE, FEB. 1, 2008. MORE INFORMATION IS THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS CHAPTER 7 the appropriate section or identified applicable checklist. documentation or special inspection is necessary to verify compliance, that method of compliance will be specified in methods acceptable to the enforcing agency which demonstrate substantial conformance. When specific limited to, construction documents, plans, specifications, builder or installer certification, inspection reports, or other Documentation used to show compliance with this code shall include but is not 703.1 DOCUMENTATION. 703 VERIFICATIONS project they are inspecting for compliance with this code. the Special inspectors shall be independent entities with no financial interest in the materials or Note: shall be closely related to the primary job function, as determined by the local agency. recognized state, national or international association, as determined by the local agency. The area of certification particular type of inspection or task to be performed. In addition, the special inspector shall have a certification from a this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with [BSC] When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall homes in California according to the Home Energy Rating System (HERS). 2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate project they are inspecting for compliance with this code. 1. Special inspectors shall be independent entities with no financial interest in the materials or the Notes: 4. Other programs acceptable to the enforcing agency. 3. Successful completion of a third party apprentice training program in the appropriate trade. performance contractors, and home energy auditors. 2. Certification by a statewide energy consulting or verification organization, such as HERS raters, building 1. Certification by a national or regional green building program or standard publisher. considered by the enforcing agency when evaluating the qualifications of a special inspector: other certifications or qualifications acceptable to the enforcing agency, the following certifications or education may be the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition to other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or When required by the enforcing agency, the owner or the 702.2 SPECIAL INSPECTION [HCD]. 5. Other programs acceptable to the enforcing agency. 4. Programs sponsored by manufacturing organizations. 3. Training programs sponsored by trade, labor or statewide energy consulting or verification organizations. 2. Public utility training programs. 1. State certified apprenticeship programs. Examples of acceptable HVAC training and certification programs include but are not limited to the following: responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC systems. certification program. Uncertified persons may perform HVAC installations when under the direct supervision and installation of HVAC systems including ducts and equipment by a nationally or regionally recognized training or HVAC system installers shall be trained and certified in the proper 702.1 INSTALLER TRAINING. 702 QUALIFICATIONS edacceptable. Use of alternate design temperatures necessary to ensure the system functions are Exception: Equipment Selection), or other equivalent design software or methods. 3. Select heating and cooling equipment according to ANSI/ACCA 3 Manual S - 2014 (Residential ASHRAE handbooks or other equivalent design software or methods. 2. Duct systems are sized according to ANSI/ACCA 1 Manual D - 2014 (Residential Duct Systems), Load Calculation), ASHRAE handbooks or other equivalent design software or methods. 1. The heat loss and heat gain is established according to ANSI/ACCA 2 Manual J - 2011 (Residential sized, designed and have their equipment selected using the following methods: Heating and air conditioning systems shall be 4.507.2 HEATING AND AIR-CONDITIONING SYSTEM DESIGN. 4.507 ENVIRONMENTAL COMFORT 2. Lighting integral to bathroom exhaust fans shall comply with the California Energy Code. tub/shower combination. 1. For the purposes of this section, a bathroom is a room which contains a bathtub, shower or Notes: integral (i.e., built-in) b. A humidity control may be a separate component to the exhaust fan and is not required to be adjustment. equal to 50% to a maximum of 80%. A humidity control may utilize manual or automatic means of a. Humidity controls shall be capable of adjustment between a relative humidity range less than or humidity control. 2. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a 1. Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building. following: Each bathroom shall be mechanically ventilated and shall comply with the 4.506.1 Bathroom exhaust fans. 4.506 INDOOR AIR QUALITY AND EXHAUST recommendations prior to enclosure. enclosure in wall or floor cavities. Wet-applied insulation products shall follow the manufacturers' drying Insulation products which are visibly wet or have a high moisture content shall be replaced or allowed to dry prior to acceptable to the enforcing agency provided at the time of approval to enclose the wall and floor framing. 3. At least three random moisture readings shall be performed on wall and floor framing with documentation of each piece verified. 2. Moisture readings shall be taken at a point 2 feet (610 mm) to 4 feet (1219 mm) from the grade stamped end found in Section 101.8 of this code. moisture verification methods may be approved by the enforcing agency and shall satisfy requirements 1. Moisture content shall be determined with either a probe-type or contact-type moisture meter.Equivalent moisture content. Moisture content shall be verified in compliance with the following: shall not be installed. Wall and floor framing shall not be enclosed when the framing members exceed 19 percent Building materials with visible signs of water damage 4.505.3 MOISTURE CONTENT OF BUILDING MATERIALS. 3. A slab design specified by a licensed design professional. 2. Other equivalent methods approved by the enforcing agency. ACI 302.2R-06. shrinkage, and curling, shall be used. For additional information, see American Concrete Institute, a vapor barrier in direct contact with concrete and a concrete mix design, which will address bleeding, 1. A 4-inch (101.6 mm) thick base of 1/2 inch (12.7mm) or larger clean aggregate shall be provided with following: A capillary break shall be installed in compliance with at least one of the 4.505.2.1 Capillary break. California Residential Code, Chapter 5, shall also comply with this section. California Building Code, Chapter 19, or concrete slab-on-ground floors required to have a vapor retarder by the Concrete slab foundations required to have a vapor retarder by 4.505.2 CONCRETE SLAB FOUNDATIONS. .California Building Standards CodeBuildings shall meet or exceed the provisions of the 4.505.1 General. 4.505 INTERIOR MOISTURE CONTROL SIGNOFF INSPECTOR SIGNOFF INSPECTOR SIGNOFF INSPECTOR SIGNOFF INSPECTOR ENVIRONMENTAL QUALITY (continued)DIVISION 4.5 5. Other methods acceptable to the enforcing agency. 0121, CSA 0151, CSA 0153 and CSA 0325 standards. Wood Association, the Australian AS/NZS 2269, European 636 3S standards, and Canadian CSA 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered CCR, Title 17, Section 93120, et seq.). 3. Product labeled and invoiced as meeting the Composite Wood Products regulation (see 2. Chain of custody certifications. 1. Product certifications and specifications. by the enforcing agency. Documentation shall include at least one of the following: Verification of compliance with this section shall be provided as requested 4.504.5.1 Documentation. by or before the dates specified in those sections, as shown in Table 4.504.5 formaldehyde as specified in ARB's Air Toxics Control Measure for Composite Wood (17 CCR 93120 et seq.), composite wood products used on the interior or exterior of the buildings shall meet the requirements for Hardwood plywood, particleboard and medium density fiberboard 4.504.5 COMPOSITE WOOD PRODUCTS. February 2010 (also known as Specification 01350). Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers", Version 1.1, 4. Meet the California Department of Public Health, "Standard Method for the Testing and Evaluation of 3. Certification under the Resilient Floor Covering Institute (RFCI) FloorScore program. 2. Products certified under UL GREENGUARD Gold (formerly the Greenguard Children & Schools program). the Collaborative for High Performance Schools (CHPS) High Performance Products Database. in Version 1.1, February 2010 (also known as Specification 01350), certified as a CHPS Low-Emitting Material Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," 1. Products compliant with the California Department of Public Health, "Standard Method for the Testing and resilient flooring shall comply with one or more of the following: Where resilient flooring is installed , at least 80% of floor area receiving 4.504.4 RESILIENT FLOORING SYSTEMS. All carpet adhesive shall meet the requirements of Table 4.504.1.4.504.3.2 Carpet adhesive. requirements of the Carpet and Rug Institute's Green Label program. All carpet cushion installed in the building interior shall meet the 4.504.3.1 Carpet cushion. Gold.TM4. Scientific Certifications Systems Indoor Advantage 3. NSF/ANSI 140 at the Gold level. February 2010 (also known as Specification 01350). Organic Chemical Emissions from Indoor Sources Using Environmental Chambers" Version 1.1, 2. California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile 1. Carpet and Rug Institute's Green Label Plus Program. requirements of at least one of the following: All carpet installed in the building interior shall meet the testing and product 4.504.3 CARPET SYSTEMS. AS SHOWN OF SHEETS RESIDENTIAL MANDATORY MEASURES, SHEET 1 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 8/17/2024 Checklist Cal Green T-1.3 DRAWN JOB DATE SCALE REVISIONS BY SHEET DESIGN M INH V. TRAN 18891 SAN CARLO S ST. FO UNTAIN VALLEY CA 92708 714-726-5175 m inhvantran10@ yahoo.com No. Exp. CIVIL RE G ISTERED PROFESSIONAL ENG INE ER STATE OF CALIFORNIA MINH V. TRAN 65250 9-30-25 SANTA ANA, CA 92706 2726 STRAW BERRY LANE, UNIT 2 NEW DETACHED A.D.U. PRO JECT: SANTA ANA, CA 92706 2726 STRAW BERRY LANE ADDRESS: DESCRIPTION 2 1 2 2726 W Strawberry Ln & Unit# 23/17/2025 RESTRICTIVE NOTICE DATE REVISIONS SHEET DESCRIPTION PROJECT OWNER PROJECT ADDRESS STAMP NO: REVISIONS DATE SIGNED: 10/3/24 THESE DESIGNS, DRAWINGS, AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF DONG ENGINEERING. THESE DRAWINGS CANNOT BE COPIED, TRANSFERRED, OR REPRODUCED NOR CAN ANY OTHER STRUCTURES BE BUILT FROM THEM WITHOUT WRITTEN CONSENT. SHEET DE#: TEL- 714-617-5979 GARDEN GROVE, CA 92841 7661 GARDEN GROVE BLVD., DONG ENGINEERING, INC. INFO@DONGENGINEERING.COM 240357 AD U AD U : 2 7 2 6 S T R A W B E R R Y L N , U N I T 2 SA N T A A N A , C A 9 2 7 0 6 MA I N H O U S E : 2 7 2 6 S T R A W B E R R Y L N , 2726 W Strawberry Ln & Unit# 23/17/2025 RESTRICTIVE NOTICE DATE REVISIONS SHEET DESCRIPTION PROJECT OWNER PROJECT ADDRESS STAMP NO: REVISIONS DATE SIGNED: 10/3/24 THESE DESIGNS, DRAWINGS, AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF DONG ENGINEERING. THESE DRAWINGS CANNOT BE COPIED, TRANSFERRED, OR REPRODUCED NOR CAN ANY OTHER STRUCTURES BE BUILT FROM THEM WITHOUT WRITTEN CONSENT. SHEET DE#: TEL- 714-617-5979 GARDEN GROVE, CA 92841 7661 GARDEN GROVE BLVD., DONG ENGINEERING, INC. INFO@DONGENGINEERING.COM 240357 AD U AD U : 2 7 2 6 S T R A W B E R R Y L N , U N I T 2 SA N T A A N A , C A 9 2 7 0 6 MA I N H O U S E : 2 7 2 6 S T R A W B E R R Y L N , 2726 W Strawberry Ln & Unit# 23/17/2025 PROPOSED FRONT PORCH PROJECT ADDRESS: 2726 STRAWBERRY AVE., SANTA ANA, CA 92706 ENGINEER: LY PHAN, P.E., RCE 63381., EXP. 09/30/2024 ADDRESS: 10820 KEENAN PL., STANTON CA90680 PHONE NO.: (714)-548-1233 EMAIL: EMAILLY10@gmail.com DATE SIGNED: 07/22/2024. 2726 W Strawberry Ln & Unit# 23/17/2025 DESIGN CRITERIA: Roof Load Asphalt Shingle roof = 3.5 psf Sheathing = 1. 5 psf Roof Rafter = 2. 5 psf Insulation = 1.5 psf Solar = 2.0 psf Misc. = 4.0 psf --------------------------------------------------------- Total Roof Dead Load = 15.0 psf LL = 20.0 psf DL + LL = 35.0 psf Ceiling Load without storage DL = 5.0 psf LL =10.0 psf Ceiling Load with storage DL = 5.0 psf LL =20.0 psf Exterior Wall DL = 14.0 psf Interior Wall DL = 10.0 psf Allowable Soil bearing pressure = 1,500 psf 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 20232726 Strawberry.wsw July 21, 2024 12:03:29 -5'0'5'10'15'20'25'30'35'40'45' -10' -5' 0' 5' 10' 15' 20' 25' 30' D-1 A-1 1- 1 1- 3 1- 2 A-3A-2 D-3D-2 D-5D-4 A-5A-4 3- 1 7- 1 B-2 6- 1 5- 1 C-1 B-1 C-2 4- 1 2- 1 8- 2 8- 1 371 27 188 77 81 77 81 371 63.5 92.7100.4 100.4 100.4100.4100.4 100.4 121.2121.2 ~ 121.9136.9 ~ 137.2121.8 ~ 122.6122.6 ~ 126.1126.1 ~ 129.0129.0 ~ 132.2132.2132.2 ~ 125.8125.8 ~ 120.8 99.261 43 6 17 7 18 1 43 6 46 49 . 6 15 0 . 0 14 5 . 0 ~ 1 4 7 . 9 14 7 . 9 ~ 1 5 5 . 7 15 5 . 7 ~ 1 5 9 . 3 15 1 . 6 ~ 1 5 2 . 4 15 2 . 4 ~ 1 5 4 . 5 15 4 . 5 ~ 1 5 4 . 9 15 4 . 9 ~ 1 5 2 . 4 16 0 . 0 ~ 1 5 5 . 0 15 5 . 0 ~ 1 4 5 . 7 13 8 . 0 ~ 1 3 7 . 3 14 4 . 2 43 . 8 2199 163 4 182 6 2073 1714 1526 20 6 7 191 0 22 0 5 186 5 Loads: Seismic (Qe); Forces: 0.7E + 0.6D; E = pQe + 0.2 Sds D; p(NS) = 1.0; p(EW) = 1.0; Sds = 1.0; Flexible distribution Vertical element required C Factored compression force (lbs) Factored hold-down force (lbs) Factored shearline force (lbs) Applied point load or discontinuous shearline force (lbs) Unfactored dead load (plf,lbs) Unfactored applied shear load (plf) Level 1 of 1 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 20232726 Strawberry.wsw July 21, 2024 12:03:29 -5'0'5'10'15'20'25'30'35'40'45'50' -15' -10' -5' 0' 5' 10' 15' 20' 25' 30' 35' D-1 A-1 1- 1 1- 3 1- 2 A-3A-2 D-3D-2 D-5D-4 A-5A-4 3- 1 7- 1 B-2 6- 1 5- 1 C-1 B-1 C-2 4- 1 2- 1 8- 2 8- 1 50.0 97.4 97.4 ~ 122.7 122.7 ~ 97.4 50.0 39 . 8 39 . 8 ~ 3 4 . 2 69 . 3 ~ 5 6 . 7 56 . 7 ~ 6 3 . 7 63 . 7 ~ 5 3 . 8 53 . 8 ~ 6 5 . 1 30 . 0 ~ 3 5 . 6 35 . 6 -7.3 68.7 68.7 ~ 115.5 115.5 ~ 68.7 -7.3 -8 . 5 -8 . 5 ~ - 7 . 3 68 . 7 ~ 1 2 2 . 8 12 2 . 8 ~ 1 3 8 . 0 13 8 . 0 ~ 1 1 6 . 5 11 6 . 5 ~ 6 8 . 3 -7 . 7 ~ - 9 . 1 -9 . 1 1388 858 1065 1308 995 789 21 4 1 1874 23 5 5 1900 Loads: Directional Case 1 Wind (W); Forces: 0.6W + 0.6D; Flexible distribution Vertical element required C Factored compression force (lbs) Factored hold-down force (lbs) Factored shearline force (lbs) Applied point load or discontinuous shearline force (lbs) Unfactored uplift wind load (plf,lbs) Unfactored dead load (plf,lbs) Unfactored applied shear load (plf) Level 1 of 1 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 2023 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 Project Information COMPANY AND PROJECT INFORMATION Company Project Gemini Design DESIGN SETTINGS Design Code IBC 2021/AWC SDPWS 2021 Wind Standard ASCE 7-16 Directional (All heights) Seismic Standard ASCE 7-16 Load Combinations For Design (ASD) 0.70 Seismic + 0.60 Dead 0.60 Wind + 0.60 Dead For Deflection (Strength) 1.00 Seismic + 0.90 Dead 1.00 Wind + 0.90 Dead Building Code Capacity Modification Wind Seismic 1.00 1.00 Service Conditions and Load Duration Duration Factor - Temperature Range - Moisture Content Fabrication Service 19% (<=19%) 10% (<=19%) Max Shearwall Offset [ft] Plan (within story) 8.00 Elevation (between stories) - Maximum Height-to-width Ratio Wood panels Blocked Unblocked Fiberboard Lumber Wind Seismic Gypsum Blocked Unblocked 3.5 2.0 - - - 2.0 1.5 Ignore shear resistance contribution of... Wall segments Seismic Side with invalid aspect ratio Any gypsum, lumber, fiberboard Forces based on... Hold-downs Applied loads Drag struts Applied loads Shearwall relative rigidity: Wall capacity Non-identical materials and construction on the shearline: Allowed, except for material type Deflection Equation: 3-term from SDPWS 4.3-1 Drift limit for wind design: 1 / 500 story height FTAO strap: Continuous at top of highest opening and bottom of lowest SITE INFORMATION Risk Category Category II - All others Wind ASCE 7-16 Directional (All heights) Seismic ASCE 7-16 12.8 Equivalent Lateral Force Procedure Design Wind Speed 110 mph Exposure Exposure C Enclosure Partially open Structure Type Regular Building System Bearing Wall Design Category D Site Class D Topographic Information [ft] Shape - Height - Length - Site Location: - Elev: 0ft Rigid building - Static analysis Spectral Response Acceleration S1: 0.470g Ss: 1.330g Fundamental Period E-W N-S T Used 0.129s 0.129s Approximate Ta 0.129s 0.129s Maximum T 0.181s 0.181s Response Factor R 6.50 6.50 Fa: 1.20 Fv: 1.83 Case 2 N-S loadsE-W loads Eccentricity (%)15 15 Loaded at 75% Min Wind Loads: Walls Roofs 16 psf 8 psf Serviceability Wind Speed 100 mph 1 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 Structural Data STORY INFORMATION Hold-down Story Floor/Ceiling Wall Length subject to Bolt Elev [ft] Depth [in] Height [ft] shrinkage [in]length [in] Ceiling 12.83 0.0 Level 1 2.83 10.0 10.00 13.75 14.5 Foundation 2.00 BLOCK and ROOF INFORMATION Block Roof Panels Dimensions [ft]Face Type Slope Overhang [ft] Block 1 1 Story E-W Ridge Location X,Y =0.00 0.00 North Side 18.4 1.50 Extent X,Y =40.50 24.50 South Side 18.4 1.50 Ridge Y Location, Offset 12.25 0.00 East Gable 90.0 1.50 Ridge Elevation, Height 16.91 4.08 West Gable 90.0 1.50 Block 2 1 Story N-S Ridge Location X,Y =24.50 24.50 North Gable 90.0 1.50 Extent X,Y =16.00 5.00 South Joined 161.6 1.00 Ridge X Location, Offset 32.50 0.00 East Side 18.4 1.50 Ridge Elevation, Height 15.49 2.66 West Side 18.4 1.50 Block 3 1 Story N-S Ridge Location X,Y =22.00 -7.50 North Joined 161.6 1.50 Extent X,Y =18.50 7.50 South Gable 90.0 1.50 Ridge X Location, Offset 31.25 0.00 East Side 18.4 1.50 Ridge Elevation, Height 15.91 3.08 West Side 18.4 1.50 2 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 SHEATHING MATERIALS by WALL GROUP Sheathing Fasteners Apply Grp Surf Material Ratng Thick GU Ply Or Gvtv Size Type RS Eg Fd Bk Notes in in lbs/in in in 1 Ext Structural sheath 24/0 3/8 -3 Horz 25000 6d Common N 6 6 Y Legend: Grp – Wall Design Group number, used to reference wall in other tables (created by program) Surf – Exterior or interior surface when applied to exterior wall Ratng – Span rating, see SDPWS Table C4.2.3C Thick – Nominal panel thickness GU - Gypsum underlay thickness Ply – Number of plies (or layers) in construction of plywood sheets Or – Orientation of longer dimension of sheathing panels or lumber planks. Dbl. = Double diagonal. Gvtv – Shear stiffness in lb/in. of depth from SDPWS Tables C4.2.3A-B Type – Fastener type from SDPWS Tables 4.3A-D: Common: common wire nail; Box: galvanized box nail; Casing: casing nail; Roof: galvanized roofing nail; Cooler: cooler nail; WBoard: wallboard nail; Screw: drywall screw; Gauge: nail measured by gauge; Galv: galvanized gauge nail; GWB: Gypsum wallboard blued nail Size - From Tables 4.3A-D and Table A1; shown in Wall Input fastener dropdown Common nails: 6d = 0.113 x 2”, 8d = 0.131 x 2.5”, 10d = 0.148 x 3”, 12d = 0.148 x 3.5” Box or casing nails: 6d = 0.099 x 2”, 8d = 0.113 x 2.5”, 10d = 0.128 x 3”, 12d = 0.126 x 3.5” Gauge, roofing and GWB nails: 13 ga = 0.92” x 1-1/8”; 11 ga = 0.120” x 1-1/8” (GWB nail for gypsum lath & plaster), 1-1/4” (gyp. L&P), 1-1/2” (wire lath & plaster, 1/2” fiberboard ,1/2” GWB), 1-3/4” (GSB, 5/8” GWB, 25/32” fiberboard, 2-ply GWB base), 2-3/8” (2-ply GWB face) Cooler or wallboard nail: 5d = .086” x 1-5/8”; 6d = .092” x 1-7/8”; 8d = .113” x 2-3/8”; 6/8d = 6d base ply, 8d face ply for 2-ply GWB. Drywall screws: No. 6, 1-1/4” long. RS – Ring-shank nails (non-shearwalls only), with increased withdrawal capacity as per NDS 12.2.3.2. Eg – Panel edge fastener spacing. For lumber sheathing, no. of nails per board at shear wall boundary. For 2-ply GWB, spacing of all nails in face ply. Fd – Field spacing interior to panels. For lumber sheathing, no. of nails per board at interior studs. For 2-ply GWB, spacing of all nails in face ply. Bk – Sheathing is nailed to blocking at all panel edges; Y(es) or N(o) Apply Notes – Notes below table legend which apply to sheathing side FRAMING MATERIALS and STANDARD WALL by WALL GROUP Wall Species Grade b d Spcg SG E Fcp Standard Wall Grp in in in psi^6 1 D.Fir-L Stud 1.50 3.50 16 0.50 1.40 625 Legend: Wall Grp – Wall Design Group b – Stud breadth (thickness) d – Stud depth (width) Spcg – Maximum on-centre spacing of studs for design, actual spacing may be less. SG – Specific gravity E – Modulus of elasticity Standard Wall - Standard wall designed as group. Fcp - Compressive strength perpendicular to grain Notes: Check manufacture requirements for stud size, grade and specific gravity (G) for all shearwall hold-downs. The following factors are applied to Fcp for compressive design and deformation under wall segment end studs : Bearing area factor Cb from NDS 3.10.4, under window openings. 3 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 Loads WIND SHEAR LOADS (as entered or generated) Level 1 Magnitude Trib Block F Element Load Wnd Surf Prof Location [ft] [lbs,plf,psf]Ht Case Dir Dir Start End Start End [ft] Block 1 W L Gable 1 W->E Wind Line 0.00 12.25 0.0 62.1 Block 1 W Wall Min W->E Wind Line 0.00 24.50 40.0 Block 1 W L Gable Min W->E Wind Line 0.00 12.25 0.0 32.6 Block 1 W Wall 1 W->E Wind Line 0.00 24.50 76.0 Block 1 W R Gable 1 W->E Wind Line 12.25 24.50 62.1 0.0 Block 1 W R Gable Min W->E Wind Line 12.25 24.50 32.6 0.0 Block 1 E L Gable Min W->E Lee Line 0.00 12.25 0.0 32.6 Block 1 E L Gable 1 W->E Lee Line 0.00 12.25 0.0 28.6 Block 1 E Wall 1 W->E Lee Line 0.00 24.50 35.1 Block 1 E Wall Min W->E Lee Line 0.00 24.50 40.0 Block 1 E R Gable Min W->E Lee Line 12.25 24.50 32.6 0.0 Block 1 E R Gable 1 W->E Lee Line 12.25 24.50 28.6 0.0 Block 1 W L Gable Min E->W Lee Line 0.00 12.25 0.0 32.6 Block 1 W Wall Min E->W Lee Line 0.00 24.50 40.0 Block 1 W Wall 1 E->W Lee Line 0.00 24.50 35.1 Block 1 W L Gable 1 E->W Lee Line 0.00 12.25 0.0 28.6 Block 1 W R Gable 1 E->W Lee Line 12.25 24.50 28.6 0.0 Block 1 W R Gable Min E->W Lee Line 12.25 24.50 32.6 0.0 Block 1 E Wall Min E->W Wind Line 0.00 24.50 40.0 Block 1 E Wall 1 E->W Wind Line 0.00 24.50 76.0 Block 1 E L Gable Min E->W Wind Line 0.00 12.25 0.0 32.6 Block 1 E L Gable 1 E->W Wind Line 0.00 12.25 0.0 62.1 Block 1 E R Gable 1 E->W Wind Line 12.25 24.50 62.1 0.0 Block 1 E R Gable Min E->W Wind Line 12.25 24.50 32.6 0.0 Block 1 S Roof Min S->N Wind Line -1.50 42.00 18.3 Block 1 S Roof 1 S->N Wind Line -1.50 42.00 -7.3 Block 1 S Wall Min S->N Wind Line 0.00 40.50 40.0 Block 1 S Wall 1 S->N Wind Line 0.00 40.50 76.0 Block 1 N Roof 1 S->N Lee Line -1.50 42.00 50.0 Block 1 N Roof Min S->N Lee Line -1.50 42.00 18.3 Block 1 N Wall 1 S->N Lee Line 0.00 40.50 47.5 Block 1 N Wall Min S->N Lee Line 0.00 40.50 40.0 Block 1 S Roof Min N->S Lee Line -1.50 42.00 18.3 Block 1 S Roof 1 N->S Lee Line -1.50 42.00 50.0 Block 1 S Wall 1 N->S Lee Line 0.00 40.50 47.5 Block 1 S Wall Min N->S Lee Line 0.00 40.50 40.0 Block 1 N Roof 1 N->S Wind Line -1.50 42.00 -7.3 Block 1 N Roof Min N->S Wind Line -1.50 42.00 18.3 Block 1 N Wall Min N->S Wind Line 0.00 40.50 40.0 Block 1 N Wall 1 N->S Wind Line 0.00 40.50 76.0 Block 2 W L Roof 1 W->E Wind Line 16.50 26.00 -0.0 -9.1 Block 2 W L Roof Min W->E Wind Line 16.50 26.00 0.0 12.6 Block 2 W Ctr Roof 1 W->E Wind Line 26.00 31.00 -9.1 Block 2 W Ctr Roof Min W->E Wind Line 26.00 31.00 12.6 Block 2 E L Roof 1 W->E Lee Line 16.50 26.00 0.0 35.6 Block 2 E L Roof Min W->E Lee Line 16.50 26.00 0.0 12.6 Block 2 E Ctr Roof Min W->E Lee Line 26.00 31.00 12.6 Block 2 E Ctr Roof 1 W->E Lee Line 26.00 31.00 35.6 Block 2 W L Roof 1 E->W Lee Line 16.50 26.00 0.0 35.6 Block 2 W L Roof Min E->W Lee Line 16.50 26.00 0.0 12.6 Block 2 W Ctr Roof Min E->W Lee Line 26.00 31.00 12.6 Block 2 W Ctr Roof 1 E->W Lee Line 26.00 31.00 35.6 Block 2 E L Roof 1 E->W Wind Line 16.50 26.00 -0.0 -9.1 Block 2 E L Roof Min E->W Wind Line 16.50 26.00 0.0 12.6 Block 2 E Ctr Roof Min E->W Wind Line 26.00 31.00 12.6 Block 2 E Ctr Roof 1 E->W Wind Line 26.00 31.00 -9.1 Block 2 N L Gable Min S->N Lee Line 24.50 32.50 0.0 21.3 Block 2 N L Gable 1 S->N Lee Line 24.50 32.50 0.0 25.3 Block 2 N R Gable Min S->N Lee Line 32.50 40.50 21.3 0.0 Block 2 N R Gable 1 S->N Lee Line 32.50 40.50 25.3 0.0 Block 2 N L Gable 1 N->S Wind Line 24.50 32.50 0.0 40.4 Block 2 N L Gable Min N->S Wind Line 24.50 32.50 0.0 21.3 Block 2 N R Gable 1 N->S Wind Line 32.50 40.50 40.4 0.0 Block 2 N R Gable Min N->S Wind Line 32.50 40.50 21.3 0.0 Block 3 W Ctr Roof 1 W->E Wind Line -9.00 -1.50 -8.5 4 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 WIND SHEAR LOADS (as entered or generated) (continued) Block 3 W Ctr Roof Min W->E Wind Line -9.00 -1.50 14.3 Block 3 W R Roof 1 W->E Wind Line -1.50 9.25 -8.5 -0.0 Block 3 W R Roof Min W->E Wind Line -1.50 9.25 14.3 0.0 Block 3 E Ctr Roof 1 W->E Lee Line -9.00 -1.50 39.8 Block 3 E Ctr Roof Min W->E Lee Line -9.00 -1.50 14.3 Block 3 E R Roof Min W->E Lee Line -1.50 9.25 14.3 0.0 Block 3 E R Roof 1 W->E Lee Line -1.50 9.25 39.8 0.0 Block 3 W Ctr Roof 1 E->W Lee Line -9.00 -1.50 39.8 Block 3 W Ctr Roof Min E->W Lee Line -9.00 -1.50 14.3 Block 3 W R Roof 1 E->W Lee Line -1.50 9.25 39.8 0.0 Block 3 W R Roof Min E->W Lee Line -1.50 9.25 14.3 0.0 Block 3 E Ctr Roof Min E->W Wind Line -9.00 -1.50 14.3 Block 3 E Ctr Roof 1 E->W Wind Line -9.00 -1.50 -8.5 Block 3 E R Roof 1 E->W Wind Line -1.50 9.25 -8.5 -0.0 Block 3 E R Roof Min E->W Wind Line -1.50 9.25 14.3 0.0 Block 3 S L Gable Min S->N Wind Line 22.00 31.25 0.0 24.6 Block 3 S L Gable 1 S->N Wind Line 22.00 31.25 0.0 46.8 Block 3 S R Gable 1 S->N Wind Line 31.25 40.50 46.8 0.0 Block 3 S R Gable Min S->N Wind Line 31.25 40.50 24.6 0.0 Block 3 S L Gable Min N->S Lee Line 22.00 31.25 0.0 24.6 Block 3 S L Gable 1 N->S Lee Line 22.00 31.25 0.0 29.2 Block 3 S R Gable Min N->S Lee Line 31.25 40.50 24.6 0.0 Block 3 S R Gable 1 N->S Lee Line 31.25 40.50 29.2 0.0 Legend: Block - Block used in load generation Accum. = loads from one block combined with another Manual = user-entered loads (so no block) F - Building face (north, south, east or west) Element - Building surface on which loads generated or entered Load Case - One of the following: ASCE 7 All Heights: Case 1 or 2 from Fig 27.3-8 or minimum loads from 27.1.5 ASCE 7 Low-rise: Reference corner and Case A or B from Fig 28.3-1 or minimum loads from 28.3.4 Wind Dir - Direction of wind for loads with positive magnitude, also direction of MWFRS. Surf Dir - Windward or leeward side of the building for loads in given direction Prof - Profile (distribution) Location - Start and end points on building element Magnitude - Start = intensity of uniform and point loads or leftmost intensity of trapezoidal load, End = right intensity of trap load Trib Ht - Tributary height of area loads only Notes: All loads entered by the user or generated by program are specified (unfactored) loads.The program applies a load factor of 0.60 to wind loads before distributing them to the shearlines. 5 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 DEAD LOADS (for hold-down calculations) Shear Level Profile Tributary Location [ft]Mag [lbs,psf,psi] Line Width [ft] Start End Start End A 1 Line 0.00 3.00 140.0* A 1 Line 3.00 11.00 140.0* A 1 Line 11.00 23.00 140.0* A 1 Line 23.00 27.00 140.0* A 1 Line 27.00 40.50 140.0* B 1 Line 0.00 10.50 100.0* B 1 Line 0.50 10.50 100.0* B 1 Line 10.50 23.50 100.0* B 1 Line 10.50 23.50 100.0* C 1 Line 0.00 10.00 140.0* C 1 Line 10.00 14.00 140.0* C 1 Line 14.00 29.00 140.0* C 1 Line 29.00 37.00 140.0* C 1 Line 37.00 40.50 140.0* 1 1 Line 0.00 7.50 140.0* 1 1 Line 7.50 17.50 140.0* 1 1 Line 17.50 24.50 140.0* 2 1 Line 0.00 24.50 100.0* 2 1 Line 10.50 14.00 100.0* 2 1 Line 14.00 24.00 100.0* 3 1 Line 0.00 10.50 100.0* 3 1 Line 0.00 10.00 100.0* 3 1 Line 14.00 24.50 100.0* 4 1 Line 0.00 2.00 140.0* 4 1 Line 2.00 12.00 140.0* 4 1 Line 12.00 24.50 140.0* 6 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 BUILDING MASSES Level 1 Magnitude Trib Force Building Block Wall Profile Location [ft] [lbs,plf,psf]Width Dir Element Line Start End Start End [ft] E-W Roof Block 1 1 Line -1.50 26.00 326.2 326.2 E-W Roof Block 1 4 Line -1.50 26.00 326.2 326.2 E-W Roof Block 2 Line 24.50 31.00 142.5 142.5 E-W Roof Block 2 4 Line 24.50 31.00 142.5 142.5 E-W Roof Block 3 3 Line -9.00 0.00 161.2 161.2 E-W Roof Block 3 4 Line -9.00 0.00 161.2 161.2 E-W R Gable Block 1 1 Line 0.00 12.25 57.1 0.0 E-W L Gable Block 1 1 Line 12.25 24.50 0.0 57.1 E-W L Gable Block 1 4 Line 0.00 12.25 57.1 0.0 E-W R Gable Block 1 4 Line 12.25 24.50 0.0 57.1 N-S Roof Block 1 A Line -1.50 42.00 206.2 206.2 N-S Roof Block 1 C Line -1.50 42.00 206.2 206.2 N-S Roof Block 2 C Line 23.00 42.00 37.5 37.5 N-S Roof Block 2 Line 23.00 42.00 60.0 60.0 N-S Roof Block 3 Line 20.50 42.00 78.8 78.8 N-S Roof Block 3 A Line 20.50 42.00 56.2 56.2 N-S R Gable Block 2 Line 24.50 32.50 37.3 0.0 N-S L Gable Block 2 Line 32.50 40.50 0.0 37.3 N-S L Gable Block 3 Line 22.00 31.25 43.1 0.0 N-S R Gable Block 3 Line 31.25 40.50 0.0 43.1 Both Wall 1-1 n/a 1 Line 0.00 7.50 70.0 70.0 Both Wall 1-2 n/a 1 Line 7.50 17.50 70.0 70.0 Both Wall 1-4 n/a 1 Line 17.50 24.50 70.0 70.0 Both Wall 1-3 n/a Line 10.50 14.00 50.0 50.0 Both Wall 2-2 n/a 2 Line 0.00 24.50 50.0 50.0 Both Wall 2-3 n/a Line 14.00 24.00 50.0 50.0 Both Wall 2-1 n/a Line 0.00 10.50 50.0 50.0 Both Wall 3-1 n/a 3 Line 0.00 10.00 50.0 50.0 Both Wall 3-2 n/a Line 14.00 24.50 50.0 50.0 Both Wall 4-1 n/a 4 Line 0.00 2.00 70.0 70.0 Both Wall 4-2 n/a 4 Line 2.00 12.00 70.0 70.0 Both Wall 4-3 n/a 4 Line 12.00 24.50 70.0 70.0 Both Wall A-1 n/a A Line 0.00 3.00 70.0 70.0 Both Wall A-2 n/a A Line 3.00 11.00 70.0 70.0 Both Wall A-3 n/a A Line 11.00 23.00 70.0 70.0 Both Wall A-4 n/a A Line 23.00 27.00 70.0 70.0 Both Wall A-5 n/a A Line 27.00 40.50 70.0 70.0 Both Wall B-2 n/a B Line 0.50 10.50 50.0 50.0 Both Wall B-4 n/a B Line 10.50 23.50 50.0 50.0 Both Wall B-1 n/a Line 0.00 10.50 50.0 50.0 Both Wall B-3 n/a Line 10.50 23.50 50.0 50.0 Both Wall C-1 n/a C Line 0.00 10.00 70.0 70.0 Both Wall C-2 n/a C Line 10.00 14.00 70.0 70.0 Both Wall C-3 n/a C Line 14.00 29.00 70.0 70.0 Both Wall C-4 n/a C Line 29.00 37.00 70.0 70.0 Both Wall C-5 n/a C Line 37.00 40.50 70.0 70.0 Legend: Force Dir - Direction in which the mass is used for seismic load generation, E-W, N-S, or Both Building element - Roof, gable end, wall or floor area used to generate mass, wall line for user-applied masses, Floor F# - refer to Plan View for floor area number Wall line - Shearline that equivalent line load is assigned to Location - Start and end points of equivalent line load on wall line Trib Width. - Tributary width; for user applied area loads only 7 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 SEISMIC LOADS Level 1 Force Profile Location [ft]Mag [lbs,plf,psf] Dir Start End Start End E-W Line -9.00 -1.50 49.6 49.6 E-W Point -7.50 -7.50 61 61 E-W Line -1.50 0.00 150.0 150.0 E-W Point 0.00 0.00 436 436 E-W Line 0.00 2.00 145.0 147.9 E-W Line 2.00 7.50 147.9 155.7 E-W Line 7.50 10.00 155.7 159.3 E-W Line 10.00 10.50 151.6 152.4 E-W Point 10.50 10.50 177 177 E-W Line 10.50 12.00 152.4 154.5 E-W Line 12.00 12.25 154.5 154.9 E-W Line 12.25 14.00 154.9 152.4 E-W Point 14.00 14.00 181 181 E-W Line 14.00 17.50 160.0 155.0 E-W Line 17.50 24.00 155.0 145.7 E-W Line 24.00 24.50 138.0 137.3 E-W Point 24.50 24.50 436 436 E-W Line 24.50 26.00 144.2 144.2 E-W Line 26.00 31.00 43.8 43.8 E-W Point 29.50 29.50 46 46 N-S Line -1.50 0.00 63.5 63.5 N-S Point 0.00 0.00 371 371 N-S Line 0.00 0.50 92.7 92.7 N-S Line 0.50 3.00 100.4 100.4 N-S Line 3.00 10.00 100.4 100.4 N-S Point 7.00 7.00 27 27 N-S Line 10.00 10.50 100.4 100.4 N-S Point 10.50 10.50 188 188 N-S Line 10.50 11.00 100.4 100.4 N-S Line 11.00 14.00 100.4 100.4 N-S Point 13.50 13.50 77 77 N-S Line 14.00 20.50 100.4 100.4 N-S Point 16.50 16.50 81 81 N-S Line 20.50 22.00 121.2 121.2 N-S Point 22.00 22.00 77 77 N-S Line 22.00 23.00 121.2 121.9 N-S Line 23.00 23.50 136.9 137.2 N-S Point 23.50 23.50 81 81 N-S Line 23.50 24.50 121.8 122.6 N-S Line 24.50 27.00 122.6 126.1 N-S Line 27.00 29.00 126.1 129.0 N-S Line 29.00 31.25 129.0 132.2 N-S Line 31.25 32.50 132.2 132.2 N-S Line 32.50 37.00 132.2 125.8 N-S Line 37.00 40.50 125.8 120.8 N-S Point 40.50 40.50 371 371 N-S Line 40.50 42.00 99.2 99.2 Legend: Loads in table can be accumulation of loads from several building masses, so they do not correspond with a particular building element. Location - Start and end of load in direction perpendicular to seismic force direction Notes: All loads entered by the user or generated by program are specified (unfactored) loads.The program applies a load factor of 0.70 and redundancy factor to seismic loads before distributing them to the shearlines. 8 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 Design Summary SHEARWALL DESIGN Wind Shear Loads, Flexible Diaphragm All shearwalls have sufficient design capacity. Seismic Loads, Flexible Diaphragm All shearwalls have sufficient design capacity. HOLD-DOWN DESIGN Wind Loads, Flexible Diaphragm All hold-downs have sufficient design capacity. Seismic Loads, Flexible Diaphragm All hold-downs have sufficient design capacity. COMPRESSION FORCE DESIGN Wind Loads, Flexible Diaphragm Bottom plate has sufficient perpendicular-to-grain compressive capacity under all wall end studs. Seismic Loads, Flexible Diaphragm Bottom plate has sufficient perpendicular-to-grain compressive capacity under all wall end studs. Refer to the Deflection table for possible issues regarding fastener slippage (SDPWS Table C4.2.3D) for walls that otherwise pass. 9 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 Flexible Diaphragm Wind Design ASCE 7 Directional (All Heights) Loads SHEAR RESULTS N-S W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line 1 Level 1 Ln1, Lev1 - S->N - - 2141 - - - - - - 3360 - - N->S - - 2133 - - - - - - 3360 - Wall 1-2 1 S->N 178.4 - 2141 - 1.0 - 280 - 280 3360 0.64 1 N->S 177.7 - 2133 - 1.0 - 280 - 280 3360 0.63 Line 4 Ln4, Lev1 - S->N - - 2355 - - - - - - 3360 - - N->S - - 2338 - - - - - - 3360 - Wall 4-1 1 S->N 196.2 - 2355 - 1.0 - 280 - 280 3360 0.70 1 N->S 194.9 - 2338 - 1.0 - 280 - 280 3360 0.70 E-W W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line A Level 1 LnA, Lev1 - Both - - 1388 - - - - - - 3136 - Wall A-2 1 Both 123.9 - 991 - 1.0 - 280 - 280 2240 0.44 Wall A-4 1 Both 99.1 - 396 - .80 - 280 - 224 896 0.44 Line C LnC, Lev1 - Both - - 1308 - - - - - - 3136 - Wall C-2 1 Both 93.4 - 374 - .80 - 280 - 224 896 0.42 Wall C-4 1 Both 116.8 - 934 - 1.0 - 280 - 280 2240 0.42 Legend: W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^" means that this wall is critical for all walls in the Standard Wall group. For Dir - Direction of wind force along shearline. v – Design shear force on segment = ASD-factored shear force per unit length of full-height sheathing (FHS) vmax/vft - Perforated walls: Collector and in-plane anchorage force as per SDPWS eqn. 4.3-9 = V/FHS/Co. FHS is factored for narrow segments as per 4.3.3.4 FTAO walls: Shear force in piers above and below either openings or piers beside opening(s). Aspect ratio factor does not apply to these piers. V – ASD factored shear force. For shearline: total shearline force. For wall: total of all segments on wall. For segment: force on segment Asp/Cub – For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.5.3. For segment or FTAO pier: Aspect ratio factor from SDPWS 4.3.5.5.1. For perforated wall: Either Cub or sum bi / FHS, where bi is segment length adjusted per SDPWS 4.3.3.4. Int, Ext - Nominal unit shear capacity of interior and exterior sheathing, factored by Table 4.3-1 Note 3 for framing specific gravity and Note 10 for presence of hold-downs. For wall segments, also include unblocked factor Cub and aspect ratio adjustments. Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-6. C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness-based using Eqns. 4.3-3,-4. Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. V – Total factored shear capacity of shearline, wall or segment. Crit Resp – Response ratio = v/Cmb = design shear force/unit shear capacity. "S" indicates that the seismic design criterion was critical in selecting wall. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,1. 10 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 Hold-Down and Compression Design (flexible wind design) Level 1 Tensile Hold-down Line- Location [ft] Load or Compressive Stud Force [lbs]Cap Crit Wall Posit'n X Y Case Shear Dead Uplift Cmb'd Hold-down [lbs]Resp. Line 1 V Elem 0.00 0.12 1 0 70 70 Compression V Elem 0.00 0.88 1 0 70 70 Compression V Elem 0.00 6.13 1 0 105 105 Compression V Elem 0.00 7.38 1 0 105 105 Compression 1-2 L End 0.00 7.63 1 2378 504 1874 HDU2-SDS 3075 0.61 1-2 L End 0.00 7.63 1 -2369 840 3209 Compression 6562 0.49 V Elem 7.00 10.63 1 0 245 245 Compression V Elem 7.00 13.88 1 0 245 245 Compression 1-2 R End 0.00 19.38 1 2369 504 1865 HDU2-SDS 3075 0.61 1-2 R End 0.00 19.38 1 -2378 840 3218 Compression 6562 0.49 V Elem 0.00 19.63 1 0 350 350 Compression V Elem 0.00 24.38 1 0 350 350 Compression Line 4 4-1 L End 40.50 0.12 1 2404 504 1900 HDU2-SDS 3075 0.62 4-1 L End 40.50 0.12 1 -2387 840 3227 Compression 6562 0.49 4-1 R End 40.50 11.88 1 2387 504 1883 HDU2-SDS 3075 0.61 4-1 R End 40.50 11.88 1 -2404 840 3244 Compression 6562 0.49 V Elem 40.50 12.13 1 0 35 35 Compression V Elem 40.50 12.38 1 0 35 35 Compression V Elem 40.50 17.63 1 0 35 35 Compression V Elem 40.50 17.87 1 0 35 35 Compression V Elem 40.50 23.13 1 0 105 105 Compression V Elem 40.50 24.38 1 0 105 105 Compression Line A V Elem 0.12 0.00 1 0 210 210 Compression V Elem 2.88 0.00 1 0 210 210 Compression A-2 L End 3.13 0.00 1 1279 336 943 HDU2-SDS 3075 0.31 A-2 L End 3.13 0.00 1 -1279 560 1839 Compression 6562 0.28 A-2 R End 10.88 0.00 1 1279 336 943 HDU2-SDS 3075 0.31 A-2 R End 10.88 0.00 1 -1279 560 1839 Compression 6562 0.28 V Elem 11.13 0.00 1 0 35 35 Compression V Elem 11.38 0.00 1 0 35 35 Compression V Elem 15.63 0.00 1 0 105 105 Compression V Elem 16.88 0.00 1 0 105 105 Compression V Elem 21.13 0.00 1 0 140 140 Compression V Elem 22.88 0.00 1 0 140 140 Compression A-4 L End 23.13 0.00 1 1057 168 889 HDU2-SDS 3075 0.29 A-4 L End 23.13 0.00 1 -1057 280 1337 Compression 6562 0.20 A-4 R End 26.88 0.00 1 1057 168 889 HDU2-SDS 3075 0.29 A-4 R End 26.88 0.00 1 -1057 280 1337 Compression 6562 0.20 V Elem 27.13 0.00 1 0 70 70 Compression V Elem 27.88 0.00 1 0 70 70 Compression V Elem 32.13 0.00 1 0 175 175 Compression V Elem 34.38 0.00 1 0 175 175 Compression V Elem 39.63 0.00 1 0 70 70 Compression V Elem 40.38 0.00 1 0 70 70 Compression Line C V Elem 0.12 24.50 1 0 350 350 Compression V Elem 4.88 24.50 1 0 350 350 Compression C-2 L End 10.13 24.50 1 997 168 829 HDU2-SDS 3075 0.27 C-2 L End 10.13 24.50 1 -996 280 1276 Compression 6562 0.19 C-2 R End 13.88 24.50 1 997 168 829 HDU2-SDS 3075 0.27 C-2 R End 13.88 24.50 1 -996 280 1276 Compression 6562 0.19 V Elem 14.13 24.50 1 0 35 35 Compression V Elem 14.38 24.50 1 0 35 35 Compression V Elem 19.63 24.50 1 0 420 420 Compression V Elem 25.38 24.50 1 0 420 420 Compression V Elem 28.63 24.50 1 0 35 35 Compression V Elem 28.88 24.50 1 0 35 35 Compression C-4 L End 29.13 24.50 1 1205 336 869 HDU2-SDS 3075 0.28 C-4 L End 29.13 24.50 1 -1205 560 1765 Compression 6562 0.27 C-4 R End 36.88 24.50 1 1205 336 869 HDU2-SDS 3075 0.28 C-4 R End 36.88 24.50 1 -1205 560 1765 Compression 6562 0.27 V Elem 37.13 24.50 1 0 245 245 Compression V Elem 40.38 24.50 1 0 245 245 Compression Legend: Line-Wall: At wall or opening – Shearline and wall number 11 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 At vertical element – Shearline Posit'n – Position of stud pack that hold-down is attached to or which is applying compression force: V Elem – Vertical element: column or strengthened studs required where not at wall end or opening L or R End – At left or right wall end L or R Op n – At left or right side of opening n t @ Op n – Uplift force t at opening n from offset opening in perforated wall above, from SDPWS 4.3.6.4.2.1 Location – Co-ordinates in Plan View Load Case – Results are for critical load case: ASCE 7 All Heights: Case 1 or 2 from Fig. 27.3-8 ASCE 7 Low-rise: Windward corner(s) and Case A or B from Fig. 28.3-1 ASCE 7 Minimum loads (27.1.5 / 28.3.4): "Min" Tensile Hold-down or Compressive Stud Force – Upwards force on hold-down at one end of the wall or downward force on bottom plate under studs at the other end, for each force direction. Includes forces transferred from upper levels. Shear – Overturning component = V x h / beff from SDPWS Eqn. 4.3-7; V = force on segment, ASD-factored by 0.60; h = wall height, beff = wall segment length – (tension stud pack width + hold-down anchor bolt offset) – (1/2 compression stud pack width). For perforated walls = V x h / Co sum (bi) from SDPWS Eqn. 4.3-8. Dead – Dead load resisting component, factored for ASD by 0.60 for tension and 1.0 for compression Uplift – Uplift wind load component, factored for ASD by 0.60 Cmb'd – Sum of ASD-factored overturning, dead and uplift forces. May also include the uplift force t from perforated walls from SDPWS 4.3.6.4.2.1 when openings are staggered. Hold-down – Device model number from hold-down database; "Compression" for bearing of end stud pack on bottom plate Cap – Hold-downs: Allowable ASD tension load from database; Compression: allowable ASD bearing force = Ct CM Cb Fcp A; A = cross sectional area of end studs. Refer to Framing materials table for details Crit. Resp. – Critical Response = Combined ASD force / Allowable ASD tension load Notes: HDU2-SDS2.5 for studs with thickness > 0'-3" and depth > 0'-3.5" : Uses 6 1/4" x 2.5" SDS heavy-duty screws; 5/8" anchor bolt. Refer to the Shear Line Dimensions table for wall height h, effective segment length beff and perforated wall adjusted sum of bi, to the Story Table for joist depth, and to the Shear Results table for perforated factor Co. Most severe of wind load cases is used for overturning calculation. Designer is responsible for design of connection from wall to floor or foundation for shear force shown in Shear Results table. Refer to SDPWS 4.3.6.4.3 for foundation anchor bolt requirements. 12 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 COLLECTOR FORCES (flexible wind design) Level 1 Drag Strut Strap/Blocking Line- Position on Wall Location [ft] Load Force [lbs]Force [lbs] Wall or Opening X Y Case ---> <------> <--- Line 1 1-2 Left Wall End 0.00 7.50 -655 653 1-2 Right Wall End 0.00 19.50 437 -435 Line 4 4-1 Right Wall End 40.50 12.00 1202 -1193 Line A A-2 Left Wall End 3.00 0.00 -103 103 A-2 Right Wall End 11.00 0.00 614 -614 A-4 Left Wall End 23.00 0.00 203 -203 A-4 Right Wall End 27.00 0.00 463 -463 Line C C-2 Left Wall End 10.00 24.50 -323 323 C-2 Right Wall End 14.00 24.50 -78 78 C-4 Left Wall End 29.00 24.50 -563 563 C-4 Right Wall End 37.00 24.50 113 -113 Legend: Line-Wall - Shearline and wall number Position…- Side of opening or wall end that drag strut is attached to Location - Co-ordinates in Plan View Load Case - Results are for critical load case: ASCE 7 All heights Case 1 or 2 ASCE 7 Low-rise corner; Case A or B Drag strut Force - Axial force in transfer element at openings, gaps, or changes in design shear along shearline. + : tension; - : compression. Based on ASD-factored shearline force (vmax from 4.3.6.4.1.1 for perforated walls) Strap/Blocking Force – For FTAO walls, force transferred from above and below opening to shearwall pier. -> Due to shearline force in the west-to-east or south-to-north direction <- Due to shearline force in the east-to-west or north-to-south direction 13 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 MWFRS DEFLECTION (flexible wind design) These deflections are used to determine shearwall stiffness for force distribution Wall,W Bending Ga Nail slip Shear Hold Total segment Gp Dir Srf v b h A Defl kips/ Vn en Defl Defl Defl plf ft ft sq.in in in lbs in in in in Level 1 Line 1 1-2 1 S->N ExtS 178.4 12.00 10.00 10.5 .008 8.4 140 .029 .211 0.27 0.49 N->S ExtS 177.7 12.00 10.00 10.5 .008 8.4 140 .029 .211 0.27 0.49 Line 4 4-1 1 S->N ExtS 196.2 12.00 10.00 10.5 .009 8.4 140 .029 .233 0.27 0.51 N->S ExtS 194.9 12.00 10.00 10.5 .009 8.4 140 .029 .231 0.27 0.51 Line A A-2 1 Both ExtS 123.9 8.00 10.00 10.5 .008 8.4 140 .029 .147 0.37 0.52 A-4 1 Both ExtS 99.1 4.00 10.00 10.5 .013 8.4 140 .029 .117 0.75 0.88 Line C C-2 1 Both ExtS 93.4 4.00 10.00 10.5 .013 8.4 140 .029 .111 0.74 0.86 C-4 1 Both ExtS 116.8 8.00 10.00 10.5 .008 8.4 140 .029 .138 0.36 0.51 Legend: Wall, segment – Wall and segment between openings, e.g. B-3,2 = second segment on Wall 3 on Shearline B. W Gp – Wall design group, refer to Sheathing and Framing Materials tables. Dir – Force direction. Srf – Wall surface = Int(erior) or Ext(erior) for perimeter walls, 1 or 2 for interior partitions; Comb = Combined v and Ga for identical materials on each side; S = Ga from side with stronger shear resistance; W = 2 x Ga of weaker side. v – ASD shear force per unit distance on wall segment. Unblocked walls = v / Cub as per SDPWS 4.3.4.3, Cub = Unblocked factor from 4.3.5.3, shown in the Shear Results table. Perforated walls = vmax from Eqn. 4.3-9, as per 4.3.4.2. FTAO walls = Unit shear force in pier beside opening(s). b – Wall or segment length. Segmented wall or FTAO wall segments = Width of wall segment between openings. Perforated wall = Sum of FHS segments, modified as in 4.3.3.4 per 4.3.4.2. FTAO wall = Length of wall including openings. h – Wall height. FTAO piers = Distance from bottom of opening to top of wall; for end segments, results using that distance and the wall height are averaged. Defl – Horizontal shear wall deflection due to given term: Bending = 8vh^3 / EAb; A = Effective cross sectional area of segment end stud(s), E = stud mod. of elasticity in Framing Materials table For i studs at one end and j at the other, A = 2 (i^2 j + j^2 i) / (i + j)^2 x area of one stud, based on Ex. C4.3.4-3 Shear = vh / 1000 Ga; Ga = vw / (vw / Gvtv + 0.75 en), from SDPWS Ex. C4.3.4-1. vw = ASD sheathing capacity. Gvtv = Shear stiffness from C4.3.4, shown in Sheathing Materials table. en = Nail slip from Table C4.2.3D of form aVn^b for WSP, constant for other materials. Vn = Shear force per nail along panel edge at ASD capacity vw. Hold – Anchorage system (hold-down) = da x h / beff. da = Vertical hold-down displacement; refer to Hold-down Displacement table for components. beff = Effective wall segment length = b - (tension stud pack width + hold-down anchor bolt offset) - (1/2 compression stud pack width) beff is given in the Shear Wall Dimensions table. For FTAO walls, hold-down device at end of wall is applied to all segments, as per APA T555. Total Defl – Deflection from bending + shear + hold-down, as per Eqn. 4.3-2. For FTAO walls, the average of the values for the segments, as per APA T555. 14 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 MWFRS HOLD-DOWN DISPLACEMENT (flexible wind design) These displacements are used to determine deflections for force distribution Wall,Hold-Tensio n Vert. Displacement Slippage Shrink Comp.Crush Total Horz segment Dir down force Manuf Add da Vf da +Extra force da da Defl lbs in in in lbs in in lbs in in in Level 1 Line 1 1-2 S->N HDU2-SDS 1874 .054 .002 0.055 - - .248 3218 0.01 0.32 0.27 N->S HDU2-SDS 1865 .053 .002 0.055 - - .248 3209 0.01 0.32 0.27 Line 4 4-1 S->N HDU2-SDS 1900 .054 .002 0.056 - - .248 3244 0.01 0.32 0.27 N->S HDU2-SDS 1883 .054 .002 0.056 - - .248 3227 0.01 0.32 0.27 Line A A-2 Both HDU2-SDS 943 .027 .001 0.028 - - .248 1839 0.01 0.28 0.37 A-4 Both HDU2-SDS 889 .025 .001 0.026 - - .248 1337 0.01 0.28 0.75 Line C C-2 Both HDU2-SDS 829 .024 .001 0.025 - - .248 1277 0.01 0.28 0.74 C-4 Both HDU2-SDS 869 .025 .001 0.026 - - .248 1765 0.01 0.28 0.36 Legend: Wall, segment – Wall and segment between openings, e.g. B-3,2 = second segment on Wall 3 on Shearline B Dir – Force direction Tens., Comp. force – Accumulated ASD hold-down tension force T and end stud compression force C from overturning, dead loads and wind uplift da – Vertical displacements due to the following components: Vert. Displacement – Elongation when slippage calculated separately; displacement when combined elongation/slippage used Manuf – Using manufacturer's value for anchor bolt length, or no bolt contribution for connector-only elongation Unless marked with * = (ASD uplift force / ASD hold-down capacity) x max ASD elongation or displacement * - Maximum strength-level elongation or displacement is used. May result in higher than actual displacements for lightly loaded hold-downs, causing the segment to draw less force due to lower than actual stiffness. Add – Due to longer anchor bolt length than manufacturer's value, or entire bolt length for connector-only elongation = TL / ( Ab x Es ) Ab = bolt cross-sectional area Es = steel modulus = 29000000 psi L = Lb – Lh Lb = Total bolt length shown in Storey Information table Lh = Manufacturer's anchor bolt length for given displacement/elongation from hold-down database Slippage – Due to vertical slippage of hold-down fasteners attached to stud(s) when not combined with elongation Nails = en from SDPWS Table C4.2.3D using values for wood structural panels Bolts = Vf / (270,000 D^1.5) (NDS 11.3.6); D = bolt diameter, Vf = Tension force T / number of fasteners Shrink + Extra – Wood shrinkage plus extra displacement due to mis-cuts, gaps, etc. Shrinkage = 0.002 x (19% fabrication – 10% in-service moisture contents) x Ls Ls = Length between anchor bolt fasteners subject to perp-to-grain shrinkage; see Story Information table Crush – Deformation of bottom plate at compression end of wall segment = 0.02” x [ r / 0.73, r < 0.73; (1 + ( r - 0.73 ) / 0.27), 0.73 < r < 1; 2 r^3, r > 1] r = fcp / Fcp’; Fcp’ = Ct CM Fcp; fcp = C / A, A = cross sectional area of end studs Total da – Vert. Displacement + Slippage + Shrink + Crush + Extra Horz Defl – Anchorage deflection term in SDPWS Eqn. C.4.3.4-1 = h / beff x da h = Wall height. For end segments in FTAO walls, h is the average of the wall height and the distance from the bottom of opening to top of wall beff = Effective wall segment length = b - (tension stud pack width + hold-down anchor bolt offset) - (1/2 compression stud pack width) h and b are shown in Deflection table, beff in the Shear Wall Dimensions table 15 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 Flexible Diaphragm Seismic Design SEISMIC INFORMATION Level Mass Area Story Shear Fx [lbs]Shear Resistance [lbs]Diaphragm Force [lbs] [lbs] [sq.ft]E-W N-S E-W N-S E-W N-S Fpx Design Fpx Design 1 39668 992.3 4272 4272 4480 4800 5909 5909 5909 5909 All 39668 - 6103 6103 - - - - - - Legend: Mass – Sum of all generated and input building masses on level = wx in ASCE 7 Eqn. 12.8-12. Story Shear – Total ASD-factored shear force induced at level x from Eqn. 12.8-11. Shear Resistance – Lateral design strength of all shear-resisting elements on story, for use in weak story evaluation (4.1.8). Diaphragm Force – used by Shearwalls only for drag strut forces, as per Exception to 12.10.2.1. Fpx - Minimum ASD-factored force for diaphragm design from Eqns. 12.10-1, -2, and -3. Design = The greater of the story shear and Fpx + transfer forces from discontinuous shearlines, factored by overstrength (omega) as per 12.10.1.1. Omega = 2.5 as per 12.2-1. Redundancy Factor p (rho): E-W 1.00, N-S 1.00 Automatically calculated according to ASCE 7 12.3.4.2. Vertical Earthquake Load Ev Ev = 0.2 Sds D; Sds = 1.00; Ev = 0.200 D unfactored; 0.140 D factored; total dead load factor: 0.6 - 0.140 = 0.460 tension, 1.0 + 0.140 = 1.140 compression. 16 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 SHEAR RESULTS (flexible seismic design) N-S W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line 1 Level 1 Ln1, Lev1 - Both - - 2067 - - - - - - 2400 - Wall 1-2 1 Both 172.3 - 2067 - 1.0 - 200 - 200 2400 0.86 Line 4 Ln4, Lev1 - Both - - 2205 - - - - - - 2400 - Wall 4-1 1 Both 183.7 - 2205 - 1.0 - 200 - 200 2400 0.92 E-W W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line A Level 1 LnA, Lev1 - Both - - 2199 - - - - - - 2240 - Wall A-2 1^Both 196.3 - 1571 - 1.0 - 200 - 200 1600 0.98 Wall A-4 1^Both 157.1 - 628 - .80 - 200 - 160 640 0.98 Line C LnC, Lev1 - Both - - 2073 - - - - - - 2240 - Wall C-2 1 Both 148.1 - 592 - .80 - 200 - 160 640 0.93 Wall C-4 1 Both 185.1 - 1481 - 1.0 - 200 - 200 1600 0.93 Legend: W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^" means that this wall is critical for all walls in the Standard Wall group. For Dir – Direction of seismic force along shearline. v – Design shear force on segment = ASD-factored shear force per unit length of full-height sheathing (FHS) vmax/vft - Perforated walls: Collector and in-plane anchorage force as per SDPWS eqn. 4.3-9 = V/FHS/Co. FHS is factored for narrow segments as per 4.3.3.4 FTAO walls: Shear force in piers above and below either openings or piers beside opening(s). Aspect ratio factor does not apply to these piers. V – ASD factored shear force. For shearline: total shearline force. For wall: total of all segments on wall. For segment: force on segment Asp/Cub – For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.5.3. For segment or FTAO pier: Aspect ratio factor from SDPWS 4.3.5.5.1. For perforated wall: Either Cub or sum bi / FHS, where bi is segment length adjusted per SDPWS 4.3.3.4. Int, Ext - Nominal unit shear capacity of interior and exterior sheathing, factored by Table 4.3-1 Note 3 for framing specific gravity and Note 10 for presence of hold-downs. For wall segments, also include unblocked factor Cub and aspect ratio adjustments. Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-6. C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness-based using Eqns. 4.3-3,-4. Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. V – Total factored shear capacity of shearline, wall or segment. Crit Resp – Response ratio = v/Cmb = design shear force/unit shear capacity. "W" indicates that the wind design criterion was critical in selecting wall. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,1. 17 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 Hold-Down and Compression Design (flexible seismic design) Level 1 Tensile Hold-down Line- Location [ft]or Compressive Stud Force [lbs]Cap Crit Wall Posit'n X Y Shear Dead Ev Cmb'd Hold-down [lbs]Resp. Line 1 V Elem 0.00 0.12 0 70 10 80 Compression V Elem 0.00 0.88 0 70 10 80 Compression V Elem 0.00 6.13 0 105 15 120 Compression V Elem 0.00 7.38 0 105 15 120 Compression 1-2 L End 0.00 7.63 2296 504 118 1910 HDU2-SDS 3075 0.62 1-2 L End 0.00 7.63 -2296 840 118 3254 Compression 6562 0.50 1-3 L End 7.00 10.63 0 245 34 279 Compression - 1-3 R End 7.00 13.88 0 245 34 279 Compression - 1-2 R End 0.00 19.38 2296 504 118 1910 HDU2-SDS 3075 0.62 1-2 R End 0.00 19.38 -2296 840 118 3254 Compression 6562 0.50 1-4 L End 0.00 19.63 0 350 49 399 Compression - 1-4 R End 0.00 24.38 0 350 49 399 Compression - Line 4 4-1 L End 40.50 0.12 2251 504 118 1865 HDU2-SDS 3075 0.61 4-1 L End 40.50 0.12 -2251 840 118 3208 Compression 6562 0.49 4-1 R End 40.50 11.88 2251 504 118 1865 HDU2-SDS 3075 0.61 4-1 R End 40.50 11.88 -2251 840 118 3208 Compression 6562 0.49 V Elem 40.50 12.13 0 35 5 40 Compression V Elem 40.50 12.38 0 35 5 40 Compression V Elem 40.50 17.63 0 35 5 40 Compression V Elem 40.50 17.87 0 35 5 40 Compression V Elem 40.50 23.13 0 105 15 120 Compression V Elem 40.50 24.38 0 105 15 120 Compression Line A A-1 L End 0.12 0.00 0 210 29 239 Compression - A-1 R End 2.88 0.00 0 210 29 239 Compression - A-2 L End 3.13 0.00 2027 336 78 1769 HDU2-SDS 3075 0.58 A-2 L End 3.13 0.00 -2026 560 78 2665 Compression 6562 0.41 A-2 R End 10.88 0.00 2027 336 78 1769 HDU2-SDS 3075 0.58 A-2 R End 10.88 0.00 -2026 560 78 2665 Compression 6562 0.41 V Elem 11.13 0.00 0 35 5 40 Compression V Elem 11.38 0.00 0 35 5 40 Compression V Elem 15.63 0.00 0 105 15 120 Compression V Elem 16.88 0.00 0 105 15 120 Compression V Elem 21.13 0.00 0 140 20 160 Compression V Elem 22.88 0.00 0 140 20 160 Compression A-4 L End 23.13 0.00 1675 168 39 1546 HDU2-SDS 3075 0.50 A-4 L End 23.13 0.00 -1675 280 39 1994 Compression 6562 0.30 A-4 R End 26.88 0.00 1675 168 39 1546 HDU2-SDS 3075 0.50 A-4 R End 26.88 0.00 -1675 280 39 1994 Compression 6562 0.30 V Elem 27.13 0.00 0 70 10 80 Compression V Elem 27.88 0.00 0 70 10 80 Compression V Elem 32.13 0.00 0 175 25 199 Compression V Elem 34.38 0.00 0 175 25 199 Compression V Elem 39.63 0.00 0 70 10 80 Compression V Elem 40.38 0.00 0 70 10 80 Compression Line C C-1 L End 0.12 24.50 0 350 49 399 Compression - C-1 L Op 1 4.88 24.50 0 350 49 399 Compression - C-2 L End 10.13 24.50 1580 168 39 1451 HDU2-SDS 3075 0.47 C-2 L End 10.13 24.50 -1579 280 39 1899 Compression 6562 0.29 C-2 R End 13.88 24.50 1580 168 39 1451 HDU2-SDS 3075 0.47 C-2 R End 13.88 24.50 -1579 280 39 1899 Compression 6562 0.29 V Elem 14.13 24.50 0 35 5 40 Compression V Elem 14.38 24.50 0 35 5 40 Compression C-3 R Op 1 19.63 24.50 0 420 59 479 Compression - C-3 L Op 2 25.38 24.50 0 420 59 479 Compression - V Elem 28.63 24.50 0 35 5 40 Compression V Elem 28.88 24.50 0 35 5 40 Compression C-4 L End 29.13 24.50 1911 336 78 1653 HDU2-SDS 3075 0.54 C-4 L End 29.13 24.50 -1911 560 78 2549 Compression 6562 0.39 C-4 R End 36.88 24.50 1911 336 78 1653 HDU2-SDS 3075 0.54 C-4 R End 36.88 24.50 -1911 560 78 2549 Compression 6562 0.39 C-5 L End 37.13 24.50 0 245 34 279 Compression - C-5 R End 40.38 24.50 0 245 34 279 Compression - Legend: Line-Wall: At wall or opening – Shearline and wall number 18 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 At vertical element – Shearline Posit'n – Position of stud pack that hold-down is attached to: V Elem – Vertical element: column or strengthened studs required where not at wall end or opening L or R End – At left or right wall end L or R Op n – At left or right side of opening n t @ Op n – Uplift force t at opening n from offset opening in perforated wall above, from SDPWS 4.3.6.4.2.1 Location – Co-ordinates in Plan View Tensile Hold-down or Compressive Stud Force – Upwards force on hold-down at one end of the wall or downward force on bottom plate under studs at the other end, for each force direction. Includes forces transferred from upper levels. Shear – Overturning component = V x h / beff from SDPWS Eqn. 4.3-7; V = force on segment, ASD-factored by 0.70; h = wall height , beff = wall segment length – (tension stud pack width + hold-down anchor bolt offset) – (1/2 compression stud pack width). For perforated walls = V x h / Co sum (bi) from SDPWS Eqn. 4.3-8. Dead – Dead load resisting component, factored for ASD by 0.60 for tension and 1.0 for compression Ev – Vertical seismic load effect from ASCE 7 12.4.2.2 = -0.2 Sds x ASD factor x unfactored D = 0.233 SDS x factored D. Refer to Seismic Information table for more details. Cmb'd – Sum of ASD-factored overturning, dead and vertical seismic forces. May also include the uplift force t from perforated walls from SDPWS 4.3.6.4.2.1 when openings are staggered. Hold-down – Device model number from hold-down database; "Compression" for bearing of end stud pack on bottom plate Cap – Hold-downs: Allowable ASD tension load from database; Compression: Allowable ASD bearing force = Ct CM Cb Fcp A; A = cross sectional area of end studs. Refer to Framing materials table for details. Crit. Resp. – Critical Response = Combined ASD force/Allowable ASD tension load Notes: HDU2-SDS2.5 for studs with thickness > 0'-3" and depth > 0'-3.5" : Uses 6 1/4" x 2.5" SDS heavy-duty screws; 5/8" anchor bolt. Combined force from ASCE 7 2.4.1 load combination 10 = - (0.6D - 0.7Ev + 0.7Eh); Eh (from 12.4.2.1) = - shear overturning force Refer to the Shear Line Dimensions table for wall height h, effective segment length beff and perforated wall adjusted sum of bi, to the Story Table for joist depth, and to the Shear Results table for perforated factor Co. Designer is responsible for design of connection from wall to floor or foundation for shear force shown in Shear Results table. Refer to SDPWS 4.3.6.4.3 for foundation anchor bolt requirements. 19 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 COLLECTOR FORCES (flexible seismic design) Level 1 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Force [lbs]Force [lbs] Wall or Opening X Y ---> <------> <--- Line 1 Shearline force 2859 2859 1-2 Left Wall End 0.00 7.50 -875 875 1-2 Right Wall End 0.00 19.50 584 -584 Line 4 Shearline force 3050 3050 4-1 Right Wall End 40.50 12.00 1556 -1556 Line A Shearline force 3041 3041 A-2 Left Wall End 3.00 0.00 -225 225 A-2 Right Wall End 11.00 0.00 1346 -1346 A-4 Left Wall End 23.00 0.00 445 -445 A-4 Right Wall End 27.00 0.00 1014 -1014 Line C Shearline force 2868 2868 C-2 Left Wall End 10.00 24.50 -708 708 C-2 Right Wall End 14.00 24.50 -172 172 C-4 Left Wall End 29.00 24.50 -1234 1234 C-4 Right Wall End 37.00 24.50 248 -248 Legend: Line-Wall - Shearline and wall number Position…- Side of opening or wall end that drag strut is attached to Location - Co-ordinates in Plan View Drag strut Force - Axial force in transfer element at openings, gaps, or changes in design shear along shearline. + : tension; - : compression. Based on ASD-factored shearline force shown. For SDC C-F, it is the greater of the design shearline force and the diaphragm force Fpx, added to shearline force from story above and to forces transferred from discontinuous shearlines factored by overstrength (omega) as per 12.10.1.1. Refer to Seismic Information table for diaphragm forces and omega factor. For SDC D-F, if horizontal torsional irregularities 2, 3, or 4 are input, or vertical irregularity 4 detected or input, 25% increase from 12.3.3.4 applied. For perforated walls, this force is converted to vmax using 4.3.6.4.1.1. Strap/Blocking Force – For FTAO walls, force transferred from above and below opening to shearwall pier. -> Due to shearline force in the west-to-east or south-to-north direction <- Due to shearline force in the east-to-west or north-to-south direction 20 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 DEFLECTION (flexible seismic design) Wall,W Bending Ga Nail slip Shear Hold Total segment Gp Dir Srf v b h A Defl kips/ Vn en Defl Defl Defl plf ft ft sq.in in in lbs in in in in Level 1 Line 1 1-2 1 Both ExtS 246.1 12.00 10.00 10.5 .011 8.4 140 .029 .292 0.29 0.59 Line 4 4-1 1 Both ExtS 262.5 12.00 10.00 10.5 .012 8.4 140 .029 .311 0.29 0.61 Line A A-2 1 Both ExtS 280.5 8.00 10.00 10.5 .019 8.4 140 .029 .332 0.43 0.78 A-4 1 Both ExtS 224.4 4.00 10.00 10.5 .031 8.4 140 .029 .266 0.86 1.15 Line C C-2 1 Both ExtS 211.5 4.00 10.00 10.5 .029 8.4 140 .029 .251 0.84 1.12 C-4 1 Both ExtS 264.4 8.00 10.00 10.5 .018 8.4 140 .029 .313 0.42 0.75 Legend: Wall, segment – Wall and segment between openings, e.g. B-3,2 = second segment on Wall 3 on Shearline B. W Gp – Wall design group, refer to Sheathing and Framing Materials tables. Dir – Force direction. Srf – Wall surface = Int(erior) or Ext(erior) for perimeter walls, 1 or 2 for interior partitions; Comb = Combined v and Ga for identical materials on each side; S = Ga from side with stronger shear resistance; W = 2 x Ga of weaker side. v – Unfactored (strength-level) shear force per unit distance on wall segment = ASD force / 0.70, as per ASCE 7 12.8.6,. Unblocked walls = v / Cub as per SDPWS 4.3.4.3, Cub = Unblocked factor from 4.3.5.3, shown in the Shear Results table. Perforated walls = vmax from Eqn. 4.3-9, as per 4.3.4.2. FTAO walls = Unit shear force in pier beside opening(s). b – Wall or segment length. Segmented wall or FTAO wall segments = Width of wall segment between openings. Perforated wall = Sum of FHS segments, modified as in 4.3.3.4 per 4.3.4.2. FTAO wall = Length of wall including openings. h – Wall height. FTAO piers = Distance from bottom of opening to top of wall; for end segments, results using that distance and the wall height are averaged. Defl – Horizontal shear wall deflection due to given term: Bending = 8vh^3 / EAb; A = Effective cross sectional area of segment end stud(s), E = stud mod. of elasticity in Framing Materials table For i studs at one end and j at the other, A = 2 (i^2 j + j^2 i) / (i + j)^2 x area of one stud, based on Ex. C4.3.4-3 Shear = vh / 1000 Ga; Ga = 1.4 vs / (1.4 vs / Gvtv + 0.75 en) from SDPWS Eqn. C4.2.3-3. vs = ASD sheathing capacity. Gvtv = Shear stiffness from C4.3.4, shown in Sheathing Materials table. en = Nail slip from Table C4.2.3D, of form aVn^b for WSP, constant for other materials. Vn = Strength-level shear force per nail along panel edge at ASD capacity = 1.4 vs. Hold – Anchorage system (hold-down) = da x h / beff. da = Vertical hold-down displacement; refer to Hold-down Displacement table for components. beff = Effective wall segment length = b - (tension stud pack width + hold-down anchor bolt offset) - (1/2 compression stud pack width) beff is given in the Shear Wall Dimensions table. For FTAO walls, hold-down device at end of wall is applied to all segments, as per APA T555. Total Defl – Deflection from bending + shear + hold-down, as per Eqn. 4.3-2. For FTAO walls, the average of the values for the segments, as per APA T555. 21 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 HOLD-DOWN DISPLACEMENT (flexible seismic design) Wall,Hold-Tensio n Vert. Displacement Slippage Shrink Comp.Crush Total Horz segment Dir down force Manuf Add da Vf da +Extra force da da Defl lbs in in in lbs in in lbs in in in Level 1 Line 1 1-2 Both HDU2-SDS 2693 .073 .003 0.076 - - .248 4625 0.02 0.34 0.29 Line 4 4-1 Both HDU2-SDS 2628 .072 .003 0.074 - - .248 4560 0.02 0.34 0.29 Line A A-2 Both HDU2-SDS 2503 .068 .002 0.070 - - .248 3791 0.02 0.33 0.43 A-4 Both HDU2-SDS 2197 .059 .002 0.061 - - .248 2841 0.01 0.32 0.86 Line C C-2 Both HDU2-SDS 2060 .056 .002 0.058 - - .248 2704 0.01 0.32 0.84 C-4 Both HDU2-SDS 2338 .063 .002 0.066 - - .248 3626 0.02 0.33 0.42 Legend: Wall, segment – Wall and segment between openings, e.g. B-3,2 = second segment on Wall 3 on Shearline B Dir – Force direction Tens., Comp. force – Accumulated strength-level hold-down tension force T and end compression force C from overturning, dead loads and vertical earthquake loads da – Vertical displacements due to the following components: Vert. Displacement – Elongation when slippage calculated separately; displacement when combined elongation/slippage used Manuf – Using manufacturer's value for anchor bolt length, or no bolt contribution for connector-only elongation Unless marked with * = (ASD uplift force / ASD hold-down capacity) x max strength-level elongation or displacement * - Maximum strength-level elongation or displacement is used. May result in higher than actual displacements for lightly loaded hold-downs, causing the segment to draw less force due to lower than actual stiffness. Add – Due to longer anchor bolt length than manufacturer's value, or entire bolt length for connector-only elongation = TL / ( Ab x Es ) Ab = bolt cross-sectional area Es = steel modulus = 29000000 psi L = Lb – Lh Lb = Total bolt length shown in Storey Information table Lh = Manufacturer's anchor bolt length for given displacement/elongation from hold-down database Slippage – Due to vertical slippage of hold-down fasteners attached to stud(s) when not combined with elongation Nails = en from SDPWS Table C4.2.3D using values for wood structural panels Bolts = Vf / (270,000 D^1.5) (NDS 11.3.6); D = bolt diameter, Vf = Tension force T / number of fasteners Shrink + Extra – Wood shrinkage plus extra displacement due to mis-cuts, gaps, etc. Shrinkage = 0.002 x (19% fabrication – 10% in-service moisture contents) x Ls Ls = Length between anchor bolt fasteners subject to perp-to-grain shrinkage; see Story Information table Crush – Deformation of bottom plate at compression end of wall segment = 0.02” x [ r / 0.73, r < 0.73; (1 + ( r - 0.73 ) / 0.27), 0.73 < r < 1; 2 r^3, r > 1] r = fcp / Fcp’; Fcp’ = Ct CM Fcp; fcp = C / A, A = cross sectional area of end studs Total da – Vert. Displacement + Slippage + Shrink + Crush + Extra Horz Defl – Anchorage deflection term in SDPWS Eqn. C.4.3.4-1 = h / beff x da h = Wall height. For end segments in FTAO walls, h is the average of the wall height and the distance from the bottom of opening to top of wall beff = Effective wall segment length = b - (tension stud pack width + hold-down anchor bolt offset) - (1/2 compression stud pack width) h and b are shown in Deflection table, beff in the Shear Wall Dimensions table 22 2726 W Strawberry Ln & Unit# 23/17/2025 WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 23 2726 W Strawberry Ln & Unit# 23/17/2025 Level Member Name Results (Max UTIL %)Current Solution Comments RR1 Passed (58% M)1 piece(s) 2 x 8 DF No.2 @ 16" OC RB1 Passed (97% ΔT)1 piece(s) 5 1/4" x 11 7/8" 2.2E Parallam® PSL RB2 Passed (86% ΔT)1 piece(s) 5 1/4" x 11 1/4" 2.2E Parallam® PSL RB3 Passed (68% R)1 piece(s) 1 3/4" x 7 1/4" 1.55E TimberStrand® LSL RB4 Passed (80% R)1 piece(s) 2 x 8 DF No.2 CJ1 Passed (75% M)1 piece(s) 2 x 6 DF No.2 @ 16" OC CB1 Passed (99% R)1 piece(s) 5 1/4" x 7" 1.8E Parallam® PSL C1 Passed (62% B/C)1 piece(s) 4 x 6 DF No.2 B1 Passed (87% ΔL)1 piece(s) 3 1/2" x 9 1/4" 2.2E Parallam® PSL B2 Passed (67% M)1 piece(s) 4 x 6 DF No.2 H1 Passed (86% ΔT)1 piece(s) 4 x 8 DF No.2 2726 STRAWBERRY JOB SUMMARY REPORT ForteWEB Software Operator Job Notes 12/8/2024 5:23:57 PM UTC Hai Pham Gemini Design (714) 707-8839 hainp@uci.edu ForteWEB v3.8 File Name: 2726 STRAWBERRY NEW DETACHED ADU IN SANTA ANA Page 1 / 12 2726 W Strawberry Ln & Unit# 23/17/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)424 @ 1' 6 3/4"1482 (1.50")Passed (29%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)303 @ 2' 2 3/8"1631 Passed (19%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)985 @ 7' 8 9/16"1700 Passed (58%)1.25 1.0 D + 1.0 Lr (Alt Spans) Live Load Defl. (in)0.187 @ 7' 7 13/16"0.640 Passed (L/823)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.379 @ 7' 7 15/16"0.854 Passed (L/405)--1.0 D + 1.0 Lr (Alt Spans) Member Length : 14' 8 5/16" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 4/12 •Deflection criteria: LL (L/240) and TL (L/180). •Overhang deflection criteria: LL (2L/240) and TL (2L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Stud wall - DF 1.50"1.50"1.50"217 206 424 Blocking 2 - Beveled Plate - DF 1.50"1.50"1.50"169 162 331 Blocking •Maximum allowable bracing intervals based on applied load. •Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)10' 2" o/c Bottom Edge (Lu)14' 6" o/c Dead Roof Live Vertical Load Location (Side)Spacing (0.90)(1.25)Comments 1 - Uniform (PSF)0 to 13' 9"16"20.0 20.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by LY PHAN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, RR1 1 piece(s) 2 x 8 DF No.2 @ 16" OC ForteWEB Software Operator Job Notes 12/8/2024 5:23:57 PM UTC Hai Pham Gemini Design (714) 707-8839 hainp@uci.edu ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 2726 STRAWBERRY NEW DETACHED ADU IN SANTA ANA Page 2 / 12 2726 W Strawberry Ln & Unit# 23/17/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4904 @ 2"11484 (3.50")Passed (43%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)4328 @ 1' 3 3/8"15066 Passed (29%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)25956 @ 10' 11"37317 Passed (70%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.739 @ 10' 11"1.075 Passed (L/349)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)1.384 @ 10' 11"1.433 Passed (L/186)--1.0 D + 1.0 Lr (All Spans) Member Length : 21' 10" System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"2284 2620 4904 Blocking 2 - Stud wall - DF 3.50"3.50"1.50"2284 2620 4904 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)21' 10" o/c Bottom Edge (Lu)21' 10" o/c • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)0 to 21' 10"N/A 19.5 -- 1 - Uniform (PSF)0 to 21' 10" (Front)12'15.8 20.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by LY PHAN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, RB1 1 piece(s) 5 1/4" x 11 7/8" 2.2E Parallam® PSL ForteWEB Software Operator Job Notes 12/8/2024 5:23:57 PM UTC Hai Pham Gemini Design (714) 707-8839 hainp@uci.edu ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 2726 STRAWBERRY NEW DETACHED ADU IN SANTA ANA Page 3 / 12 2726 W Strawberry Ln & Unit# 23/17/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4880 @ 2"11484 (3.50")Passed (42%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)4251 @ 1' 2 3/4"14273 Passed (30%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)22475 @ 9' 6 1/2"33694 Passed (67%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.506 @ 9' 6 1/2"0.938 Passed (L/445)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)1.078 @ 9' 6 1/2"1.250 Passed (L/209)--1.0 D + 1.0 Lr (All Spans) Member Length : 19' 1" System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"2590 2290 4880 Blocking 2 - Stud wall - DF 3.50"3.50"1.50"2590 2290 4880 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)19' 1" o/c Bottom Edge (Lu)19' 1" o/c • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)0 to 19' 1"N/A 18.5 -- 1 - Uniform (PSF)0 to 19' 1" (Front)12'21.1 20.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by LY PHAN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, RB2 1 piece(s) 5 1/4" x 11 1/4" 2.2E Parallam® PSL ForteWEB Software Operator Job Notes 12/8/2024 5:23:57 PM UTC Hai Pham Gemini Design (714) 707-8839 hainp@uci.edu ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 2726 STRAWBERRY NEW DETACHED ADU IN SANTA ANA Page 4 / 12 2726 W Strawberry Ln & Unit# 23/17/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2787 @ 7' 6 1/4"4091 (5.50")Passed (68%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)1266 @ 6' 8 1/4"3278 Passed (39%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)-2113 @ 7' 6 1/4"3889 Passed (54%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.103 @ 3' 6 1/2"0.368 Passed (L/857)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.169 @ 3' 5 1/2"0.490 Passed (L/521)--1.0 D + 1.0 Lr (Alt Spans) Member Length : 17' 6 1/2" System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"463 614 1077 Blocking 2 - Stud wall - SPF 5.50"5.50"3.75"1255 1532 2787 Blocking 3 - Stud wall - DF 3.50"3.50"1.50"117 155 272 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)14' 10" o/c Bottom Edge (Lu)10' 4" o/c • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)0 to 17' 6 1/2"N/A 4.0 -- 1 - Uniform (PSF)0 to 7' (Front)9' 6"15.8 20.0 Default Load 2 - Tapered (PSF)7' to 16' 6" (Front)9' 6" to 0 15.8 20.0 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by LY PHAN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, RB3 1 piece(s) 1 3/4" x 7 1/4" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 12/8/2024 5:23:57 PM UTC Hai Pham Gemini Design (714) 707-8839 hainp@uci.edu ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 2726 STRAWBERRY NEW DETACHED ADU IN SANTA ANA Page 5 / 12 2726 W Strawberry Ln & Unit# 23/17/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1789 @ 5' 5 1/4"2231 (3.50")Passed (80%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)745 @ 4' 8 1/4"1631 Passed (46%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)-1052 @ 5' 5 1/4"1478 Passed (71%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.041 @ 9' 7 5/16"0.401 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.067 @ 9' 8 3/16"0.535 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) Member Length : 13' 7 1/2" System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"272 373 645 Blocking 2 - Stud wall - SPF 3.50"3.50"2.81"803 986 1789 Blocking 3 - Stud wall - DF 3.50"3.50"1.50"85 109 194 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)13' 8" o/c Bottom Edge (Lu)9' 1" o/c • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)0 to 13' 7 1/2"N/A 2.8 -- 1 - Uniform (PSF)0 to 5' (Front)8'15.8 20.0 Default Load 2 - Tapered (PSF)5' to 12' 9" (Front)8' to 0 15.8 20.0 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by LY PHAN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, RB4 1 piece(s) 2 x 8 DF No.2 ForteWEB Software Operator Job Notes 12/8/2024 5:23:57 PM UTC Hai Pham Gemini Design (714) 707-8839 hainp@uci.edu ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 2726 STRAWBERRY NEW DETACHED ADU IN SANTA ANA Page 6 / 12 2726 W Strawberry Ln & Unit# 23/17/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)508 @ 13' 11 1/4"2231 (3.50")Passed (23%)--1.0 D + 1.0 L (All Spans) Shear (lbs)255 @ 13' 4"990 Passed (26%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)-636 @ 13' 11 1/4"848 Passed (75%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.423 @ 6' 7 1/2"0.686 Passed (L/390)--1.0 D + 1.0 L (Alt Spans) Total Load Defl. (in)0.506 @ 6' 6 7/8"0.915 Passed (L/325)--1.0 D + 1.0 L (Alt Spans) Member Length : 24' 4 1/2" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor/Ceiling Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"38 162/-11 200 Blocking 2 - Stud wall - SPF 3.50"3.50"1.50"102 406 508 None 3 - Stud wall - DF 3.50"3.50"1.50"23 127/-35 150/-12 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)13' 2" o/c Bottom Edge (Lu)11' 1" o/c • Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. Dead Floor/Ceiling Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 24' 4 1/2"16"5.0 20.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by LY PHAN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, CJ1 1 piece(s) 2 x 6 DF No.2 @ 16" OC ForteWEB Software Operator Job Notes 12/8/2024 5:23:57 PM UTC Hai Pham Gemini Design (714) 707-8839 hainp@uci.edu ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 2726 STRAWBERRY NEW DETACHED ADU IN SANTA ANA Page 7 / 12 2726 W Strawberry Ln & Unit# 23/17/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4949 @ 3' 11"5020 (2.25")Passed (99%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)4935 @ 3' 2 1/2"7044 Passed (70%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)9204 @ 2' 5/8"11854 Passed (78%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.051 @ 2' 5/8"0.125 Passed (L/890)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.101 @ 2' 5/8"0.188 Passed (L/445)--1.0 D + 1.0 Lr (All Spans) Member Length : 3' 10 1/2" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Factored Accessories 1 - Stud wall - SPF 3.50"2.25"2.20"2462 54 2444 4906 1 1/4" Rim Board 2 - Stud wall - SPF 3.50"2.25"2.22"2484 54 2466 4950 1 1/4" Rim Board •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)3' 11" o/c Bottom Edge (Lu)3' 11" o/c • Side loads are assumed to not induce cross-grain tension. Dead Floor Live Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.25)Comments 0 - Self Weight (PLF)1 1/4" to 3' 11 3/4"N/A 11.5 ---- 1 - Uniform (PSF)0 to 4' 1" (Front)1' 3 15/16"5.0 20.0 -Default Load 2 - Point (lb)2' 5/8" (Front)N/A 2284 -2620 SUPPORT 2 OF RB1 3 - Point (lb)2' 5/8" (Front)N/A 2590 -2290 SUPPORT 1 OF RB2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by LY PHAN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, CB1 1 piece(s) 5 1/4" x 7" 1.8E Parallam® PSL ForteWEB Software Operator Job Notes 12/8/2024 5:23:57 PM UTC Hai Pham Gemini Design (714) 707-8839 hainp@uci.edu ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 2726 STRAWBERRY NEW DETACHED ADU IN SANTA ANA Page 8 / 12 2726 W Strawberry Ln & Unit# 23/17/2025 Wall Height: 14'Member Height: 13' 7 1/2"Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 30 50 Passed (59%)---- Compression (lbs)4880 9668 Passed (50%)1.25 1.0 D + 1.0 Lr Plate Bearing (lbs)4880 8181 Passed (60%)--1.0 D + 1.0 Lr Lateral Reaction (lbs)94 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)88 3696 Passed (2%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)320 @ mid-span 2717 Passed (12%)1.60 1.0 D + 0.6 W Total Deflection (in)0.16 @ mid-span 1.36 Passed (L/1025)--1.0 D + 0.45 W + 0.75 L + 0.75 Lr Bending/Compression 0.62 1 Passed (62%)1.25 1.0 D + 1.0 Lr •Lateral deflection criteria: Wind (L/120) •Input axial load eccentricity for this design is 16.67% of applicable member side dimension. •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Spruce-Pine-Fir Base 2X Spruce-Pine-Fir Max Unbraced Length Comments 8' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Roof Live Vertical Load Tributary Width (0.90)(1.25)Comments 1 - Point (lb)N/A 2590 2290 Default Load • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (13' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 1'23.0 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by LY PHAN Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED Level, C1 1 piece(s) 4 x 6 DF No.2 ForteWEB Software Operator Job Notes 12/8/2024 5:23:57 PM UTC Hai Pham Gemini Design (714) 707-8839 hainp@uci.edu ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 2726 STRAWBERRY NEW DETACHED ADU IN SANTA ANA Page 9 / 12 2726 W Strawberry Ln & Unit# 23/17/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1116 @ 2"4922 (2.25")Passed (23%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)1056 @ 1' 3/4"7824 Passed (13%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)7237 @ 8' 9"15519 Passed (47%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.387 @ 8' 11 7/8"0.444 Passed (L/550)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.725 @ 8' 11 7/8"0.887 Passed (L/294)--1.0 D + 1.0 Lr (All Spans) Member Length : 17' 10 1/2" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Stud wall - DF 3.50"2.25"1.50"533 588 1121 1 1/4" Rim Board 2 - Stud wall - DF 3.50"2.25"1.50"518 568 1086 1 1/4" Rim Board •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)17' 11" o/c Bottom Edge (Lu)17' 11" o/c • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)1 1/4" to 17' 11 3/4"N/A 10.1 -- 1 - Uniform (PSF)0 to 18' 1" (Front)1' 6"15.0 20.0 Default Load 2 - Point (lb)8' 9" (Front)N/A 463 614 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by LY PHAN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, B1 1 piece(s) 3 1/2" x 9 1/4" 2.2E Parallam® PSL ForteWEB Software Operator Job Notes 12/8/2024 5:23:57 PM UTC Hai Pham Gemini Design (714) 707-8839 hainp@uci.edu ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 2726 STRAWBERRY NEW DETACHED ADU IN SANTA ANA Page 10 / 12 2726 W Strawberry Ln & Unit# 23/17/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)833 @ 2"7656 (3.50")Passed (11%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)668 @ 9"2888 Passed (23%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)1444 @ 3' 9 1/2"2151 Passed (67%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.096 @ 3' 9 1/2"0.363 Passed (L/906)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.176 @ 3' 9 1/2"0.483 Passed (L/494)--1.0 D + 1.0 Lr (All Spans) Member Length : 7' 7" System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"378 455 833 Blocking 2 - Stud wall - DF 3.50"3.50"1.50"378 455 833 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)7' 7" o/c Bottom Edge (Lu)7' 7" o/c • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)0 to 7' 7"N/A 4.9 -- 1 - Uniform (PSF)0 to 7' 7" (Front)6'15.8 20.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by LY PHAN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, B2 1 piece(s) 4 x 6 DF No.2 ForteWEB Software Operator Job Notes 12/8/2024 5:23:57 PM UTC Hai Pham Gemini Design (714) 707-8839 hainp@uci.edu ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 2726 STRAWBERRY NEW DETACHED ADU IN SANTA ANA Page 11 / 12 2726 W Strawberry Ln & Unit# 23/17/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)5158 @ 1 1/2"6563 (3.00")Passed (79%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)2327 @ 10 1/4"3806 Passed (61%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)1712 @ 4' 4 11/16"2691 Passed (64%)0.90 1.0 D (All Spans) Live Load Defl. (in)0.062 @ 4' 8 13/16"0.358 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.267 @ 5' 1 5/8"0.313 Passed (L/483)--1.0 D + 1.0 Lr (All Spans) Member Length : 11' System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (5/16"). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Trimmer - DF 3.00"3.00"2.36"2948 2210 5158 None 2 - Trimmer - DF 3.00"3.00"1.50"538 80 618 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)11' o/c Bottom Edge (Lu)11' o/c Dead Roof Live Vertical Loads Location Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)0 to 11'N/A 6.4 -- 1 - Uniform (PSF)0 to 11'5'15.0 -WALL 2 - Point (lb)6"N/A 2590 2290 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by LY PHAN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level, H1 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 12/8/2024 5:23:57 PM UTC Hai Pham Gemini Design (714) 707-8839 hainp@uci.edu ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 2726 STRAWBERRY NEW DETACHED ADU IN SANTA ANA Page 12 / 12 2726 W Strawberry Ln & Unit# 23/17/2025 FOOTING/PAD ANALYSIS Soil Bearing SB = 1500 psf Concrete density dconc =150 pcf EXTERIOR FOOTING Post width parallel to footing Bp =3.5 in Footing width B =12 in Footing depth D =24 in Loads: Weight of footing W f =375 plf Roof W r =210 plf Floor W fl =101 plf Wall W w = 150 plf Total weight W total =836.25 plf Footing Width required Bf =W total / SB =6.7 in OK USE 12" Wide x 24" Deep Continuous Footing W/ (2) #5 Cont. @ T & B (U.N.O). INTERIOR FOOTING post width parallel to footing Bp =3.5 in Footing width B = 12 in Footing depth D = 24 in Loads: Weight of footing W f =375 plf Roof W r =47 plf Floor W fl =300 plf Wall W w = 45 plf Total weight W total =767 plf Footing Width required Bf =W total / SB =6.1 in OK USE 12" Wide x 24" Deep Continuous Footing W/ (2) #5 Cont. @ T & B (U.N.O). PAD @ Support 1 of RB1 Post width parallel to footing Bp =3.5 in Continuous footing F1 USE 12" WIDE X 24" DEEP CONTINUOUS FOOTING W/ (2) #5 CONT. @ T & B (U.N.O) Footing width B = 12 in Footing depth D = 24 in Loads: Weight of footing W f =375 plf Wall W w = 150 plf from 0.00' to 1.00' Total weight W total =525 plf Point load from support 1 of RB1 P =4904 lb S = 63.5 in Width 12" Capacity of Point Load on Footing Pcap = SB x S x B/144 = 7938 lb Allowable Point Load on Footing PAllow = Pcap - (W total x S)/12 = 5159 lb No Pad required PAD @ Support 2 of CB1 Post width parallel to footing Bp =3.5 in Pad Type P2 Pad width Bpad = 30 in Pad depth Dpad = 24 in Loads: Weight of Pad W p = 1875 lb Point load from support 2 of CB1 P =4950 lb Total point load Ptotal = 6825 lb Required Pad Area Apad = Ptotal / SB = 4.55 sf OK USE 2'-6" SQ. X 24" DEEP PAD W/ (5) #4 E.W. 2726 W Strawberry Ln & Unit# 23/17/2025 SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa-ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Thai Viet Phan COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org ACTING CITY MANAGER Alvaro Nuñez CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall July 10, 2024 Also sent via email to: nvtowing@gmail.com James Dung Pham Joyce Nga Pham 2726 W Strawberry Lane Santa Ana, CA. 92706 Subject: Address Assignment for a new Accessory Dwelling Unit located at 2726 West Strawberry Lane and (APN: 101-121-28) in Santa Ana, CA Dear James and Joyce, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a new Accessory Dwelling Unit located at 2726 West Strawberry Lane and (APN: 101-121- 28). Notice is hereby given that the following assigned address(es) shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address(es) to be Activated/Posted 1. 2726 W. Strawberry Lane, Unit 2 (Address for new ADU). To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 667-2709 or by email at ASevilla@santa-ana.org. Sincerely, Alexis Sevilla Planning Technician Jerry Guevara, AICP, Senior Planner 2726 W Strawberry Ln & Unit# 23/17/2025 Address Letter for 2726 W. Strawberry Lane Page 2 of 2 Exhibit A – Address Plan c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Yvette Portugal, Code Enforcement Principal Sergio Verino, Code Enforcement Principal 2726 W Strawberry Ln & Unit# 23/17/2025 ENAL YRREBWARTS 8'-0" 6'-0" 20'-0" 30'-0" 53 '-9" 28'-8" 5'-0" DATE SCALE DRAWN JOB SHEET OF SHEETS PROJECT TITL E & LOCATION : AS SHOWN REVISIONS BY A-0 DESIGN ER ENG INEE R m inh v antran1 0 @ yaho o .com FO U N TAIN VA LL E Y CA 92 7 0 8 18 8 9 1 SAN CARLO S STREE T M INH V. TRAN No. Exp. CIVIL RE G ISTERED PROFESSIONAL ENG INE E R STATE OF CALIFORNIA MINH V. TRAN 65250 9-30-25 LAWN LEGEND: CONCRETE SCALE: 1/8 " = 1'- 0" SITE PLANNO RTH 1 1 PROPERTY LINE 178.72' PROPERTY LINE 137.35' PRO PERTY LINE 125 .00 ' CL 1 PL PL PL SITE PLAN SPECIFICATION 1 2 3 4 5 6 7 PROTECT IN PLACE (E) CONCRETE BLOCK WALL PROTECT IN PLACE (E) WATER HEATER 8 PROTECT IN PLACE (E) CONDESING UNIT 9 PROTECT IN PLACE (E) WATER METER 10 PROTECT IN PLACE (E) POWER POLE PROTECT IN PLACE (E) 200 AMP ELECTRICAL METER PROTECT IN PLACE (E) 1-1/4" GAS METER 2 2 PROTECT IN PLACE (E) 6 FEET HEIGHT WOOD SIDE GATES 1 9 4 5 6 (E) WATER METER (N) WATER METER (1" MINIMUM) AWAY FROM DRIVEWAY APPROACH PER CITY STD. 3 FEET MIN. 7 8 10 DECIDED BY SCE COMPANY & PANEL EXACT LOCATION TO BE PROPOSED 200 AMP ELECTRIC METER BY THE GAS COMPANY LOCATION TO BE VERIFIED PROPOSE GAS METER 1,206 S.F EXISTING RESIDENCE 1 STORY NOT A PART SITE PLAN NOTES: SWIMMING POOL (E) FISH TANK (E) (N) 1 STORY ADU SETBACK ADU SET BACK AD U SETBACK AD U EASEMENT UTILITY SETBACK REAR YARD 18'-0" 2% MIN 4 IN SEWER LINE 11 13 11 12 13 13 PROTECTING IN PLACE (E) LANDSCAPE AREA 12 11 NON-PERMITTED STRUCTURAL DEMOLITION LOT COVERAGE FLOOR AREA ACCESSORY DWELLING UNIT ACCESSORY DWELLING UNIT 1,206 SF (E) MAIN RESIDENCE 1,206 SFEXISTING LIVING AREA (E) MAIN RESIDENCE TOTAL FLOOR AREA 86 SF PROPOSE FL. LIVING AREA EXISTING FLOOR AREA EXISTING PORCH AREA88 SF (1,206 + 1,000) = 2,204 SF230 SFEXISTING ENCLOSED PATIO 10. FOR SITE DRAINAGE INFORMATION SEE GRADING AND DRAINAGE PLANS, 9. FENCES, GATES, AND FIRE SPRINKLERS ARE TO BE INSTALLED WITH SEPARATE PERMITS, BUILDING, AND DEMOLITION OF EXISTING BUILDING. 8. A SEPARATE PERMIT IS REQUIRED FOR SWIMMING POOLS, SPA, RETAINING WALL, ACCESSORY 7. RESIDENTIAL FIRE SPINKLERS ARE ALL NEW CONTRUCTION. 6. ALL UTITLITY SERVICES, INCLUDING TELEPHONE AND ELECTRIC POWER, SHALL BE UNDERGROUND. 5. A SEPARATE PERMIT IS REQUIRED TO PERFORMED ALL WORK WITHIN STREET RIGHT OF WAY. DRIVEWAY APRONS AS MAY BE REQUIRED BY THE CITY ENGINEER. 4. REPLACE ALL BROKEN, CRACKED OR UPHEAVED CURB, CURB & GUTTER, SIDEWALK AND 3. DO NOT BLOCK NATURAL DRAINAGE COURSES FROM ADJACENT PROPERTIES. 2. LOT DRAINAGE SHALL BE CONDUCTED TO THE STREET OR AS SHOWN ON THE PLANS. 1. ALL LANDSCAPING AREAS, INCLUDING THE PARKWAY SHALL BE AUTOMATICALLY IRRIGATED. (1- STORY) SINGLE FAMILY RESIDENCE NEIGHBOR BUILDING (E) (2- STORY) SINGLE FAMILY RESIDENCE NEIGHBOR BUILDING (E) 13 13 13 NON-PERMITTED STRUCTURAL DEMOLITION PROPOSE LIVING AREA 140 SF TOTAL COVERAGE1,524 SF 1,224 SF GRAND TOTAL COVERAGE(1,524+1,224) = 2,748 SF 11,646 SF 2,748 / 11,646 = 23.6% < 35% ALLOWABLE OKLOT COVERAGE LOT SIZE = 2022 S.F. OPEN SPACE PCC DRIVEWAY (E) (N) INSTANTANEOUS TANKLESS WATER HEATER (GAS) FOR THE ADU (N) HEAT PUMP MINI SPLIT FOR THE ADU 3 11 11 11 11 12 140 SF PATIO OPEN OPEN PATIO = 140 S.F OPEN PORCH = 86 S.F FLR LV. AREA = 998 S.F 86 SF PORCH OPEN PROPOSE OPEN PATIO 998 SF PROPOSE PORCH AREA 998 SF APPROACH (E) DRIVEWAY PATIO ENCLOSED (E) PO RC H (E) 13 13 13 11 SIGNED DATE: 6/4/2024 13 CONCRETE WALKWAY PL (N) LANDSCAPE AREA TOTAL FLOOR AREA PROPOSE FL. LIVING AREA 998 SF PRIVATE/COMMON SPACE CALCULATIONS 543 455 PRIVATE AREA COMMON AREA PRIVATE/COMMON RATIO 455/998 : 543/988= 46 : 54 SAN TA AN A , CA 92 7 0 6 27 2 6 STRAW BERR Y LAN E NEW DET ACHED AD U 3 1 2 BOTANICAL NAME COMMON NAME TYPE SIZE SHRUB ITEM NO.SYMBOL QUANTITY SHRUBFRENCH LAVENDER 2' X 2' WATER NEED FROM WULCOLS LAVANDULA DENTATA LOW1 GAL 5 HEIGHT X SPREAD MATURE SIZE CALLISTEMON "LITTLE JOHN" BOTLEBRUSH LITTLE JOHN DWARF TALL FISCUE FLATMARTHON II LAWN SOD PLANTING LEGEND YES DROUGHT TOLERANT NATIVE AND/OR CALIFORNIA EXISTING LANDSCAPING TO BE PROTECTED IN PLACE 1 3 2 (N) CONCRETE WALKWAY (N) CONCRETE WALKWAY (N) CONCRETE WALKWAY 18" LATERAL SPACING DRIP EMITTER SPACING 18" O.C, IRRIGATION LEGEND SYMBOL MANUFACTURE MODEL NO.DESCRIPTION PSI RAD.GPM 30RAINBIRDSPRAY NOZZLESHE-VAN-10 F, H, T, Q 30RAINBIRDSPRAY NOZZLESHE-VAN-12 F, H, T, Q 12 10 2.37, 1.18, 0.79, 0.59 1.78, 0.89, 0.60, 0.45 1 1 1 1 1 11 1 1 1 6/28/2024 WM W/H MINI SP LIT HP E MG W/H MG (E) 2726 W STRAWBERRY LANE (N) 2726 W STRAWBERRY LANE, UNIT 2 EXHIBIT A - ADDRESS PLAN 2726 W Strawberry Ln & Unit# 23/17/2025 Page 1 of 1 EXISTING ONE & TWO FAMILY DWELLINGS ELECTRICAL SERVICES UNDERGROUND EXCEPTION CEC 2022 ELC-04 All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41- 626(b). There is a standing exception for one and two family dwellings. This exception applies only when the new electrical service is designed to be fed from below grade as well as overhead. This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the circuit breaker side of this cabinet. Only listed combination overhead and underground feed service boxes may be used to connect to an overhead utility drop. This exception to an underground fed service applies only to existing single family and two family residences. Planning & Building Agency Permits & Plan Check Section 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 Rigid Conduit Service Entrance Conductor Riser Underground Service Lateral METER Rev. 1/21/2020 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 1 To Owner: Mr. Dung Address: 2524LP 2726 Strawberry Ln, Santa Ana, CA 92706. Subject: Report of Geotechnical Engineering Investigation, Proposed Residential Development at 2726 Strawberry Ln, Santa Ana, CA 92706 Project Number: GEO252524LP Report Date: Sep. 12, 2024 Gentlemen: In accordance with your request, I am pleased to submit this geotechnical engineering report for the proposed development at subject site. The purpose of this report was to evaluate the subsurface conditions and provide recommendations for foundation designs and other relevant parameters for the proposed construction. Based on the findings of our field exploration, laboratory testing and engineering analysis, the proposed construction of the subject site for the intended use is feasible from the geotechnical engineering viewpoint, provided that specific recommendations set forth herein are followed. This opportunity to be of service is sincerely appreciated. If you have any questions pertaining to this report, please call the undersigned. Respectfully submitted, Tien Chu Dist: (2) Addressee 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 2 REPORT OF GEOTECHNICAL ENGINEERING INVESTIGATION Proposed Residential Development at 2726 Strawberry Ln, Santa Ana, CA 92706 Project Number: GEO252524LP Prepared by TMC ENGINEERS INC. 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 3 1.0 INTRODUCTION 1.1 Purpose This report presents a summary of our preliminary geotechnical engineering investigation for the proposed development at the subject site. The purposes of this investigation were to evaluate the subsurface conditions at the area of proposed construction and to provide recommendations pertinent to grading, foundation design and other relevant parameters. 1.2 Scope of Services Our scope of services included: • Review of available soil and geologic data of the area. • Logging and sampling of hand auger boring to a maximum depth of 5 feet below the existing ground surface. Boring logs are presented in Appendix “A” (Field Investigation). • Laboratory testing of representative samples collected from the proposed construction area to establish engineering characteristics of the on-site soils. The laboratory test results are presented in Appendix B (Laboratory Testing) and on the boring logs (Appendix A). • Engineering analyses of the geotechnical data obtained from our background studies, field investigation, and laboratory testing. • Preparation of this report presenting our findings, conclusions, and recommendations for the proposed development. 1.3 Proposed Construction It is anticipated that the proposed construction is a new ADU residential with a one-story house in the rear of lot site and room addition at right side of existing house. The structure of the proposed residential building is anticipated to be one story in height. Column loads are be light. Final grade is anticipated to be near the existing grade. 1.4 Site Conditions The subject site is located at South side of Strawberry Ln, North of Westminster Ave., East of Harbor Blvd, West of Fairview st., South of Trash st.. within a fully development area. An existing one story house with typical concrete driveway, sidewalks, rear yard. The subject site is relatively flat and is currently occupied by a residential house and a garage. No major surface erosions were observed at the time of our field investigation. 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 4 2.0 SUBSURFACE EXPLORATION AND LABORATORY TESTING 2.1 Subsurface Exploration Our subsurface exploration consisted of drilling hand auger boring to a maximum depth of 5 feet below the existing ground surface. Relatively undisturbed, bulk samples were collected during drilling for laboratory testing. The approximate locations of the boring are shown on the attached Site Plan. Boring logs are presented in Appendix A. 2.2 Laboratory Testing Representative samples were tested for the following parameters: Atterberg Limits, expansion index. The results of our laboratory testing along with a summary of the testing procedures are presented in Appendix B. 3.0 SUMMARY OF GEOTECHNICAL CONDITIONS 3.1 Soil Conditions Based on field observation and testing of sampler of the near ground surface soil. The ground surface soils consist of silty very fine sand. In general, these soils exist slightly moist to moist condition. 3.2 Groundwater Ground water was not encountered at a depth of about 5 feet below the existing ground surface during our subsurface investigation. Based on our review of the “Historically Highest Ground Water Contours and Borehole Log Data Locations, Anaheim and Newport Beach Quadrangle” per page # 22, it is estimated that the highest ground water level is approximate 10 feet below the existing grade. It should be noted that the CDMG ground water map is obtained by evaluating technical publications, geotechnical borehole data, water-well logs dating back to the “turn-of-the-century”. This report also indicated that ground water levels in the areas from 1960-1997 data are generally 5 to 50 feet deeper than the earlier measured data. No specific date was provided pertaining to the high ground water level. Deep footings and excavations are not proposed for this site, therefore the effect due to ground 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 5 water are not anticipated for the proposed structural. SEISMIC DESIGN CONSIDERATIONS Although no know active faults traverse through the subject site, like most of Southern California, the subject site lies within a seismically active area. Earthquake resistance structural design is recommended. Designing structural to be earthquake-proof is generally considered to be impractical, especially for private projects, due to cost limitations, significant damage to structures may be unavoidable during large earthquakes. The structural design of the proposed structures should be based on the 2022 California Building Code. The following minimum seismic parameter should be used: Latitude = 33.7619266, Longitude = - 117.906705 Site Class: D-default Ss= 1.33 S1= 0.473 SMS= 1.596 SDS=1.064 Seismic Design Category: D This minimum code values are intended to protect life and may not provide an acceptable level of protection against significant cosmetic damage and serious economic loss. A significantly higher than code lateral design parameter would be necessary to further reduce potential economic loss during a major seismic event. Structural engineers, however, often regard higher than code values as impractical for use in structural design. The structural engineer and project owner must decide what level of risk is acceptable and to assign appropriate seismic values for use in structural design. The risk of damage to the structural due to a large earthquake cannot be totally eliminated and obtain appropriate insurance as a mitigation measure is strongly recommended. 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 6 5.0 SEISMIC HAZARDS 5.1 Liquefaction Potential Liquefaction is the transformation of a granular material from a solid to a liquid state as a result of as flow land sliding, lateral spread, loss of bearing capacity, or settlement. Based on the Seismic Hazard Zones Map, Newport Beach Quadrangle, the site is located within a potential liquefaction zone. Therefore, liquefaction may occur at the site, and the property owner(s) should be aware of the risks associated with being in a potential liquefaction zone. We recommend the proposed new structures should have a strengthened footing system as recommended in this report, and the proposed new structures will be designed based on up-to-date building codes to reduce the potential adverse effects due to potential liquefaction increasing pore-water pressure. The material will then lose strength and can flow if unrestrained, thus leading to ground failure. Liquefaction can be triggered in saturated cohesionless material by short-term cyclic loading, such as shaking due to an earthquake. Ground failure that results from liquefaction can be manifested to the proposed new structures. It should be recognized that structural mitigation may not reduce the potential of the soils to liquefy during an earthquake; and there will remain some risks that the structure could still suffer damage if liquefaction occurs during a very strong earthquake. Differential settlement due to liquefaction may occur, to reduce the potential adverse effect to the proposed new structural due to potential liquefaction induced differential settlement and/or reduction in soil bearing capacity, and it is our opinion that our recommendations shall satisfy the liquefaction requirements. 5.2 Lurching Soil lurching refers to the rolling motion on the surface due to the passage of seismic surface waves. Effects of this nature are not considered significant on the subject site where the thickness of alluvium does not vary appreciably under structures. 5.3 Surface Rupture 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 7 Surface rupture is a break in the ground surface during or as a consequence of seismic activity. The potential for surface rupture on the subject site is considered negligible due to the absence of known active faults at the site. 5.4 Ground Shaking Throughout southern California, ground shaking, as a result of earthquakes, is a constant potential hazard. The relative potential for damage from this hazard is a function of the type and magnitude of earthquake events and the distance of the subject site from the event. Accordingly, proposed structures should be designed and constructed in accordance with applicable portions of the building code. 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 8 6.0 CONCLUSIONS Based on the results of our subsurface investigation, it is our opinion that the proposed residential development is feasible from a geotechnical standpoint, provided the recommendations contained herein are incorporated in the design and construction. The following is a summary of the geotechnical design and construction factors that may affect development of the site. 6.1 Seismicity Based on our studies on seismicity, there are no known active faults crossing the property. However, the site is located in a seismically active region and is subject to seismically induced ground shaking from nearby and distant faults, which is a characteristic of all Southern California areas. 6.2 Liquefaction Differential settlement due to liquefaction is roughly estimated to be about ¼ inch for a horizontal distance of 40 feet. Please note that this is only a rough estimate. 6.3 Groundwater Ground water was not encountered at a depth of about 5 feet below the existing ground surface during our subsurface investigation. In our opinion, groundwater will not be a problem during the near surface construction. 6.4 Expansion Potential Based on our field observation and testing of sample of the near ground surface on-site earth materials, the foundation subgrade soils at the site generally consisted of sandy soil with some sill and have a very low expansion potential. 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 9 7.0 RECOMMENDATIONS The following recommendations should be incorporated into the design or construction phases. 7.1 Grading 7.1.1 Site Preparation Prior to initiating grading operations, any existing vegetation, trash, debris, over-sized materials (greater than 12 inches), and other deleterious materials within fill areas should be removed from the site. 7.1.2 Surficial Soil Removals For the proposed new house, after removal of existing concrete slabs where occur and/or vegetation including roots. It is recommended that the top 2 feet thick near surface earth materials should be over-excavated and re-compacted. Removal should be extended at least 2 feet beyond building lines. No deeper removal is anticipated, however, if deeper loose soils are encountered, deeper removal and re-compaction will be required. This will be determined at the field by the project geotechnical/civil engineer, based on the actual conditions exposed at the time of site grading. The removed clean on-site earth materials without any debris, vegetation and roots can be re- used as fill or back fill material. Fill, back fill material or additional imported soils should be free of organic matter and oversize material, 6 inches or greater in diameter, placed in near-horizontal loose lift not to exceed 4 inches in thickness and moisture conditioned to slightly over optimum moisture content prior to compaction. Imported soil, if any, should have a very low expansion potential and should be geotechnical observed/tested and accepted by the geotechnical/civil engineer prior to using at the site. In general, grading at the site should be performed in accordance with the requirements of the city and under the geotechnical observation and testing of the project geotechnical / civil engineer. The compaction criteria for fill and backfill material is a minimum of 90% of the maximum density determined in accordance with ASTM Test Method D1557. 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 10 7.1.3 Structural Backfill The onsite soils may be used as compacted fill provided they are free of organic materials and debris. Fills should be placed in relatively thin lifts; brought to near optimum moisture content, then compacted to obtain at least 90 percent relative compaction based on laboratory standard ASTM D-1557-07. 7.1.4 Site Drainage Foundation and slab performance depend greatly on how well runoff waters drain from the site. This is true both during construction and over the entire life of the structure. The ground surface around structures should be graded so that water flows rapidly away from structure. Roof gutters and downspouts should be properly provided and maintained. In the future, sources of uncontrolled water, such as leaky sewer, water (domestic, irrigation) or drain pipes should be repaired if identified. The requirements of the governmental agency and the current CBC should be followed, as needed. 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 11 7.2 Shallow Foundation Design 7.2.1 Allowable foundation and Lateral Pressure: Based on our field investigation and laboratory testing results. In accordance with Section 1806.2 of the 2022 California Building Code. It is recommended that the following parameters should be considered in the foundation design and construction: For conservative, the lowest values in table 1806.2, 2022 CBC Code, allowable bearing value of 1500 pounds per square foot. 7.2.2 Settlement Distress to the existing house due to settlement of the underlying soil was not observed. Settlement of soils underlying is not a concerned for the proposed development. Under construction, differential settlement between adjacent columns is not anticipated to exceed 1/4 inch for the adjacent column spaced at a distance of about 40 feet. 7.2.3 Lateral Pressures Passive earth pressure may be computed as an equivalent fluid pressure of 150 pounds per cubic foot, with a maximum earth pressure of 1500 pounds per square foot. An allowable coefficient of friction between soil and concrete of 0.3 may be used with the dead load forces. When combining passive pressure and frictional resistance, the passive pressure component should be reduced by one-third. 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 12 7.2.4 Foundation Construction It is anticipated that the entire structure will be underlain by onsite soils of very low expansion potential. All new footings should be founded at a minimum depth of 24 inches below the lowest adjacent ground surface. All continuous footings should have at least two No. 4 reinforcing bars placed both at the top and two No. 4 reinforcing bars placed at the bottom of the footings. + New building footings: New continuous footings 12 inches wide at one-story, 15 inches wide at two-story. 24 inches deep at interior and exterior footings. Shallow pad footings at least 24 square inch and 24 inches deep. All continuous new footings should have at least two No. 4 reinforcing bars placed at the top and two No. 4 reinforcing bars placed at the bottom of the footings. 7.2.5 Concrete Slab Concrete slabs should be a minimum of 4 inches thick and reinforced with a minimum of No. 4 bars spacing at 18 inch both ways and its equivalent. All slab reinforcement should be supported to ensure proper positioning during placement of concrete. Concrete slabs in moisture sensitive areas should be underlain with a vapor barrier consist of a minimum of 10-mil vaper retarder with all laps sealed. A minimum of 2 inch of sand should be placed over the membrane to aid in uniform curing of concrete and 2 inch of sand under vapor barrier. Alternate per Cal Green code, a 4-inch-thick base of ½ inch or larger clean aggregate shall be provided with a 10-mil vaper retarder with all laps sealed in direct contact with concrete. 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 13 7.3 Temporary Trench Excavation and Backfill All trench excavations should conform to CAL-OSHA and local safety codes. All utilities trench backfill should be brought to near optimum moisture content and then compacted to obtain a minimum relative compaction of 90 percent of ASTM D-1557-07. 7.4 Nonstructural concrete Flatwork: Sidewalk and Private Driveway 4 inches (sidewalk) and 5 inch (driveway) minimum thickness reinforce concrete with # 3 at 24” on center. Crack control with saw cut or deep tool joint to a minimum of 1/3 the concrete thickness, maximum joint spacing is 5 feet (sidewalk) and 10 feet or quarter cut (driveway) whichever closer. 8.0 CORROSION POTENTIAL Sulfate attack was not observed for the existing buildings in this subjected area. Type V cement with concrete strength 3000 psi is recommended to use, Water-Cement ratio=0.5. Other requirement from government agencies, if any, can be followed. It is recommended that the subsurface soils can be corrosive to buried metal pipe. It is recommended that any underground steel utilities be blasted and given protective coating. Should additional protective measures be warranted, a corrosion specialist should be consulted. 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 14 9.0 INSPECTION As a necessary requisite to the use of this report, the following inspection is recommended: Temporary excavations. Removal of surficial soils. Backfill placement and compaction. • Foundation excavations. The geotechnical engineer should be notified at least 1 day in advance of the start of construction. A joint meeting between the client, the contractor, and the geotechnical engineer is recommended prior to the start of construction to discuss specific procedures and scheduling. 10.0 INVESTIGATION LIMITATIONS + The materials encountered on the subject site and utilized in our laboratory testing program are believed to be representative of the area. However, soil may vary in characters between the exploratory borings. Since our investigation is based on the site materials observed, selected laboratory testing, and engineering analyses, the conclusions and recommendations are professional opinion. These opinions have been derived in accordance with current standard of practice. + Based on our site investigation and recommendation, we believed that the proposed improvements will not adversely impact adjoining site. 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 15 11.0 REFERENCES Ishihara, K. and Yoshimine, M., (1992), “Evaluation of Settlements in Sand Deposits Following Liquefaction During Earthquakes”, Japanese Society of Soil Mechanics and Foundation Engineering, Vol. 32, No. 1, pp. 173-188 Guidelines for Evaluating and Mitigating Seismic Hazards in California, 2008 Special Publication 117A, revised and re-adopted September 11, 2008. T.Y. Loud, I.M. Idriss, and et. al. (2001), “Liquefaction Resistance of Soils: Summary Report from the 1996 NCEER and 1998 NCEER/NSF Workshops on Evaluation of Liquefaction Resistance of Soils”, Journal of the Geotechnical Engineering Division, American Society of Civil Engineers, Vol. 127, No. GT10, pp. 817-833. California Geological Survey “Probabilistic Seismic Hazard Mapping Ground Motion Page.” California Division of Mines and Geology, 1998, Seismic Hazard Zone Report for the Newport Beach Seismic Hazard Zone. EERC, “Recent Advances in Soil Liquefaction Engineering: A Unified and Consistent Framework”, EERC Report No. 2003-06, 26th Annual ASCE Geotehcnial Spring Seminar, Long Beach, April 30, 2003 Southern California Earthquake Center (SCEC), “Recommended Procedures for Implementation of DMG Special Publication 117, Guidelines for Analyzing and Mitigating Liquefaction Hazards in California”, March, 1999. www. conservation.ca.gov/cgs/rghm/psha/fault_parameters/pdf/Documents/B_flt.pdf Report of Geotechnical Engineering Investigation, Proposed Residential Development 930 S Birch St, Santa Ana, CA 92701; Project Number: 0119DD Report of Geotechnical Engineering Investigation, Proposed Residential Development, 601 S SUSAN ST. SANTA ANA, CA 92704. Project Number: 0116NT Report of Geotechnical Engineering Investigation, Proposed Residential Development 930 S Birch St, Santa Ana, CA 92701; Project Number: 0119DD Report of Geotechnical Engineering Investigation, Proposed Residential Development 2302 W Stanford St, Santa Ana, CA 92704; Project Number: 0120KHOA Report of Geotechnical Engineering Investigation, Proposed Residential Development 3614 W Camile St, Santa Ana, CA 92704; Project Number: 9017TMC Report of Geotechnical Engineering Investigation, Proposed Residential Development 2221 1 2 CYPRESS AVE, SANTA ANA , CA 92707; Project Number: 14120DT Report of Geotechnical Engineering Investigation, Proposed Residential Development 2108 Alona St, 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 16 Santa Ana, CA 92706; Project Number: GEO14720DT Report of Geotechnical Engineering Investigation, Proposed Residential Development 1121 S Golden W Ave, Santa Ana, CA 92704; Project Number: GEO0221KHOA Report of Geotechnical Engineering Investigation, Proposed Residential Development, 634 UNIT 2 S. BAMDAL ST., SANTA ANA, CA 92703; Project Number: GEO16121DT SOIL Report of Geotechnical Engineering Investigation, Proposed Residential Development, 2302 W La Verne Ave, Santa Ana, CA 92704; Project Number: GEO15521DT Report of Geotechnical Engineering Investigation, Proposed Residential Development, 601 AND 601 1/2 S. SUSANE ST, SANTA ANA - CA 92704; Project Number: GEO16521DT Report of Geotechnical Engineering Investigation, Proposed Residential Development 1510 & 1510 1/2 N. BEWLEY ST., SANTA ANA, CA 92703,; Project Number: GEO 16221DT Report of Geotechnical Engineering Investigation, Proposed Residential Development, 4325 W Oakfield Ave, Santa Ana, CA 92703 SOIL REPORT; Project Number: GEO12-0522ESS Report of Geotechnical Engineering Investigation, Proposed Residential Development 2018 W.11th, Santa Ana, CA. 92703; Project Number: GEO13-31222TMC Report of Geotechnical Engineering Investigation, Proposed Residential Development: 1413 N Hastings St., Santa Ana, CA 92703,; Project Number: GEO14-14022QD Report of Geotechnical Engineering Investigation, Proposed Residential Development: 5113 W Roberts Dr, Santa Ana, CA 92704; Project Number: GEO15-14523QD Report of Geotechnical Engineering Investigation, Proposed Residential Development: 1702 S Rene Dr, Santa Ana, CA 92704; Project Number: GEO16-18123DT Report of Geotechnical Engineering Investigation, Proposed Residential Development: 1021 W Cubbon St. Santa Ana, CA 92703; Project Number: GEO17-0123HP Report of Geotechnical Engineering Investigation, Proposed Residential Development 5017 W 6th St, Santa Ana, CA 92703,; Project Number: GEO18 Report of Geotechnical Engineering Investigation, Proposed Residential Development 1204 W 2nd St, Santa Ana, CA 92703; Project Number: GEO19 Report of Geotechnical Engineering Investigation, Proposed Residential Development, 1402 S Lowell St, Santa Ana, CA 92707; Project Number: GEO20 Report of Geotechnical Engineering Investigation, Proposed Residential Development 522 S Raitt St, Santa Ana, CA 92703,; Project Number: GEO21 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 17 Report of Geotechnical Engineering Investigation, Proposed Residential Development 2222 W Elder Ave, Santa Ana, CA 92704 ; Project Number: GEO22 0923LP Report of Geotechnical Engineering Investigation, Proposed Residential Development 718 S Flindridge Dr, Santa Ana, CA. 92704; Project Number: GEO23 39424TMC Report of Geotechnical Engineering Investigation, Proposed Residential Development 3925 W. Hazard Ave, Santa Ana; Project Number: GEO24 0224BT 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 18 APPENDIX A FIELD INVESTIGATION Subsurface conditions were explored by drilling hand auger boring to a maximum depth of 5 feet at approximate locations shown on the enclosed Site Plan. Upon completion of excavating, the boreholes were backfilled with onsite soils that were removed from the excavations. The drilling of the test boring was supervised by a geotechnical engineer, who continuously logged the borings and visually classified the soils in accordance with the Unified Soil Classification System. 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 19 GEOTECHNICAL LOG OF TEST HOLES Test hole Number: BH-1 Hole Diameter: 4 inches Equipment: Hand-Auger DEPTH DESCRIPTION 0ft –2 ft Poorly grade sand with sill (SP-SM), dry, fine to medium sand, medium dense, light brown 2 ft - 5ft Poorly grade sand with sill (SP-SM), dry to moist, fine sand, dense, light brown Total depth: 5 ft No Caving No free standing water Hole back fill with on-site soil 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 20 APPENDIX B LABORATORY TESTING Expansion Index Expansion Index test was conducted on the existing onsite near surface materials sampled during field investigation. The test is performed in accordance with ASTM D-4829. The testing results are presented below: Sample Location Dry Density pcf Moisture content % Expansion Index Classification BH-1 2.0’ 125 13.5 Zero Ver Low Corrosion Potential Chemical laboratory test were conducted on the existing onsite near surface materials. The rests are performed in accordance with California Test Method 417, 422, 532 and 643. The resting results are shown in table below: Sample Location PH Sulfate Content % b Wei ht Min. Resistivity ohm-cm Chloride Content ppm BH-1 0’ to 5’ 8 0.078 1,952 144 Note: N/R= Not Requested 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 21 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 22 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 23 2726 W Strawberry Ln & Unit# 23/17/2025 TMC ENGINEERS INC. Geotechnical, Structural and Civil Engineering Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com Page 24 2726 W Strawberry Ln & Unit# 23/17/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240357 Calculation Date/Time:2024-07-26T12:08:58-07:00 (Page 1 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-07-26   12:09:42 GENERAL INFORMATION 01 Project Name 240357 02 Run Title Title 24 Analysis 03 Project Location 2726 STRAWBERRY LN, UNIT 2, 04 City SANTA ANA 05 Standards Version 2022 06 Zip code 92706 07 Software Version EnergyPro 9.2 08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)0 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 3 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)998 19 Glazing Percentage (%)23.55% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type All electric 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 424-P010142639A-000-000-0000000-0000 07/26/2024 12:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 2726 W Strawberry Ln & Unit# 23/17/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240357 Calculation Date/Time:2024-07-26T12:08:58-07:00 (Page 2 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-07-26   12:09:42 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 31 38.4 26.4 Proposed Design 29.2 33.1 23.7 1.8 5.3 2.7 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 2.31 kWdc •PV System resized to 2.31 kWdc (a factor of 2.307) to achieve 'Standard Design PV' PV scaling 424-P010142639A-000-000-0000000-0000 07/26/2024 12:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 2726 W Strawberry Ln & Unit# 23/17/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240357 Calculation Date/Time:2024-07-26T12:08:58-07:00 (Page 3 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-07-26   12:09:42 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.36 1.7 0.84 5.96 -0.48 -4.26 Space Cooling 1.05 27.47 0.69 22.96 0.36 4.51 IAQ Ventilation 0.46 4.85 0.46 4.85 0 0 Water Heating 2.04 21.44 1.35 14.05 0.69 7.39 Self Utilization/Flexibility Credit 0 0 Efficiency Compliance Total 3.91 55.46 3.34 47.82 0.57 7.64 Photovoltaics -2.53 -76.55 -2.53 -75.99 Battery 0 0 Flexibility Indoor Lighting 0.86 8.06 0.86 8.06 Appl. & Cooking 2.28 25.9 2.26 25.69 Plug Loads 5.49 55.86 5.49 55.86 Outdoor Lighting 0.2 1.75 0.2 1.75 TOTAL COMPLIANCE 10.21 70.48 9.62 63.19 424-P010142639A-000-000-0000000-0000 07/26/2024 12:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 2726 W Strawberry Ln & Unit# 23/17/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240357 Calculation Date/Time:2024-07-26T12:08:58-07:00 (Page 4 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-07-26   12:09:42 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 16.96 15.64 1.32 7.78 Net EUI2 4.07 2.75 1.32 32.43 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 2.31 NA Standard (14-17%)Fixed none true 150-270 n/a n/a <=7:12 96 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Non-standard roof reflectance •Insulation below roof deck •Variable capacity heat pump compliance option (verification details from VCHP Staff report, Appendix B, and RA3) •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed 424-P010142639A-000-000-0000000-0000 07/26/2024 12:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 2726 W Strawberry Ln & Unit# 23/17/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240357 Calculation Date/Time:2024-07-26T12:08:58-07:00 (Page 5 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-07-26   12:09:42 HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Indoor air quality ventilation •Verified Refrigerant Charge •Airflow in habitable rooms (SC3.1.4.1.7) •Verified heat pump rated heating capacity •Wall-mounted thermostat in zones greater than 150 ft2 (SC3.4.5) •Ductless indoor units located entirely in conditioned space (SC3.1.4.1.8) •Compact distribution system expanded credit •Drain water heat recovery system BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 240357 998 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Living Conditioned HVAC1 998 10 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Front wall Living R-15 Wall 0 Front 407.5 78 90 Left wall Living R-15 Wall 90 Left 245 80 90 Rear wall Living R-15 Wall 180 Back 407.5 80 90 Right wall Living R-15 Wall 270 Right 245 25 90 424-P010142639A-000-000-0000000-0000 07/26/2024 12:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 2726 W Strawberry Ln & Unit# 23/17/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240357 Calculation Date/Time:2024-07-26T12:08:58-07:00 (Page 6 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-07-26   12:09:42 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Roof no Attic Living R-30 Roof No Attic n/a n/a 410 n/a n/a Roof Attic Living R-30 + R-13 Roof Attic n/a n/a 588 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Living Attic RoofLiving Ventilated 4 0.16481 0.891242 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading W1 Window Front wall Front 0 1 25 0.3 NFRC 0.23 NFRC Bug Screen W1 2 Window Front wall Front 0 1 25 0.3 NFRC 0.23 NFRC Bug Screen D4 Window Left wall Left 90 1 40 0.3 NFRC 0.23 NFRC Bug Screen D4 2 Window Left wall Left 90 1 40 0.3 NFRC 0.23 NFRC Bug Screen D4 3 Window Rear wall Back 180 1 40 0.3 NFRC 0.23 NFRC Bug Screen W3 Window Rear wall Back 180 1 12 0.3 NFRC 0.23 NFRC Bug Screen W3 2 Window Rear wall Back 180 1 12 0.3 NFRC 0.23 NFRC Bug Screen W2 Window Rear wall Back 180 1 16 0.3 NFRC 0.23 NFRC Bug Screen W1 3 Window Right wall Right 270 1 25 0.3 NFRC 0.23 NFRC Bug Screen 424-P010142639A-000-000-0000000-0000 07/26/2024 12:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 2726 W Strawberry Ln & Unit# 23/17/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240357 Calculation Date/Time:2024-07-26T12:08:58-07:00 (Page 7 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-07-26   12:09:42 OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor D1 Front wall 28 0.5 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Living 998 130.5 none 0 80%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco Attic RoofLiving Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-8 None / 0 0.112 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-8 / 2x4 R-30 Roof No Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O. C.R-30 None / None 0.032 Over Ceiling Joists: R-20.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board R-30 + R-13 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O. C.R-30 None / None 0.032 Over Ceiling Joists: R-20.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board 424-P010142639A-000-000-0000000-0000 07/26/2024 12:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 2726 W Strawberry Ln & Unit# 23/17/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240357 Calculation Date/Time:2024-07-26T12:08:58-07:00 (Page 8 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-07-26   12:09:42 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a Expanded DHW Sys 1-hers-dhw DHW Heater 1 (1) WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal)NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 40 Rheem Rheem HPLD40-1RH Outside Living Living WATER HEATING - COMPACT DISTRIBUTION 01 02 03 04 05 06 07 Dwelling Unit type Water Heating System Name Master Bath distance of furthest fixture to Water Heater (ft) Kitchen distance of furthest fixture to Water Heater (ft) Furthest Third furthest fixture to Water Heater (ft) Compactness Factor HERS Verification Dwelling DHW Sys 1 n/a n/a n/a 0.6 Expanded Credit 424-P010142639A-000-000-0000000-0000 07/26/2024 12:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 2726 W Strawberry Ln & Unit# 23/17/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240357 Calculation Date/Time:2024-07-26T12:08:58-07:00 (Page 9 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-07-26   12:09:42 WATER HEATING - DRAIN WATER HEAT RECOVERY 01 02 03 04 05 06 Dwelling Unit type DHW System and DWHR Names Installation Configuration Shower Drains Shower Drain Water Heat Recovery Efficiency (%)HERS Verification Dwelling DHW Sys 1 - 1 - DWHR-1 Equal Flow 2 43 Required WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Required Expanded Not Required Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC1 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 n/a n/a Setback HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 VCHP-ductless 1 HSPF 8 17000 13500 EERSEER 14 12 Not Zonal Single Speed Heat Pump System 1-hers-htpump 424-P010142639A-000-000-0000000-0000 07/26/2024 12:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 2726 W Strawberry Ln & Unit# 23/17/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240357 Calculation Date/Time:2024-07-26T12:08:58-07:00 (Page 10 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-07-26   12:09:42 HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Not Required 0 Not Required Not Required Yes No Yes Yes VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 10 Name Certified Low-Static VCHP System Airflow to Habitable Rooms Ductless Units in Conditioned Space Wall Mount Thermostat Air Filter Sizing &amp; Pressure Drop Rating Low Leakage Ducts in Conditioned Space Minimum Airflow per RA3.3 and SC3.3.3.4.1 Certified non-continuous Fan Indoor Fan not Running Continuously Heat Pump System 1 Not required Required Required Required Not required Not required Not required Not required Not required INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam IAQVentRpt 59 0.35 Exhaust No n/a / n/a No Yes 424-P010142639A-000-000-0000000-0000 07/26/2024 12:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 2726 W Strawberry Ln & Unit# 23/17/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240357 Calculation Date/Time:2024-07-26T12:08:58-07:00 (Page 11 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-07-26   12:09:42 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Truong Dong Dong Engineering 07/26/2024 10692 silver cir garden grove, CA 92843 (714) 204-2874 Truong Dong Dong Engineering 07/26/2024 10692 silver cir N/A garden grove, CA 92843 (714) 204-2874 424-P010142639A-000-000-0000000-0000 07/26/2024 12:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 2726 W Strawberry Ln & Unit# 23/17/2025