HomeMy WebLinkAbout2701 N Grand - PlanGENERAL NOTES 1. CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE LOCAL, STATE, AND NATIONAL CODES AND REGULATIONS. 2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO BID TO DETERMINE THE EXTENT OF WORK. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO BIDDING. 3. ALL EXISTING MATERIALS TO REMAIN WHICH ARE DAMAGED OR OTHERWISE DISTURBED BY THE CONTRACTOR'S OPERATIONS SHALL BE PATCHED OR REPAIRED TO MATCH THE EXISTING ADJACENT MATERIALS, SO THAT THE REPAIR IS IMPERCEPTIBLE. 4. DURING THE COURSE OF CONSTRUCTION, IF THE CONTRACTOR UNCOVERS ANY CODE VIOLA TION KNOWN TO HIM OR ANY DISCREPANCY WITH THE DESIGN, CONTRACTOR SHALL NOTIFY THE ARCHITECT OF SUCH IMMEDIATELY. 5. CONTRACTOR SHALL ASSEMBLE AND INSTALL MATERIALS/ PRODUCTS IN STRICT ACCORDANCE WITH THE MANUF'S RECOMMENDATIONS AND INDUSTRIAUASSOCIATION STANDARDS. 6. CONTACT ARCHITECT AND COORDINATE WITH TENANT ANY ADDITIONAL SPECIFICATIONS NOT SPECIFIED HEREIN AND/OR CLARIFICATIONS REGARDING THE CONTRACT DOCUMENTS. 7. NO CURRENT SURVEY WAS PERFORMED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY, IN WRITING, OF ANY DISCREPANCIES OR OMISSIONS TO THE TOPOGRAPHIC INFORMATION. THE CONTRACTOR(S) SHALL BE RESPONSIBLE FOR CONFIRMING THE LOCATION. STRUCTURES SHALL BE BORNE BY THE CONTRACTOR. ADDITIONALLY, THE CONTRACTOR(S) SHALL NOTIFY THE OWNER AND ENGINEER IN WRITING IF ANY ERRORS OR DISCREPANCIES ARE FOUND ON THE CONSTRUCTION DOCUMENTS (PS&E), WHICH NEGATIVELY IMPACT THE PROJECT. THE ENGINEER AND OWNER SHALL BE INDEMNIFIED OF PROBLEMS AND/OR COST WHICH MAY RESULT FROM THE CONTRACTOR'S FAILURE TO NOTIFY THE ENGINEER AND OWNER. 8. IT IS STRONGLY RECOMMENDED THAT NO CONTRACTUAL AGREEMENT OF ANY KIND BE SIGNED PRIOR TO RECEIVING AND THOROUGHLY REVIEWING ALL APPROVALS FROM ALL OF THE REGULATORY AUTHORITIES HAVING JURISDICTION OVER THIS PROJECT. SITE NOTES 1. ALL DIMENSIONS SHOWN ARE TO FACE OF CURB UNLESS NOTED OTHERWISE. 2. BASES, ANCHOR BOLTS, CONDUIT, AND WIRING FOR ALL SIGNS ARE BY THE GENERAL CONTRACTOR. 3. EXISTING MENU BOARDS AND PRE-BROWSE BOARDS TO BE REMOVED FROM BASES, REMOVED FROM SITE, AND DISPOSED UNLESS DIRECTED BY BAILIWICK. DEMO LITION NOTES 1. CONTRACTOR IS RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE TO EXISTING IMPROVEMENTS DURING CONSTRUCTION, SUCH AS, BUT NOT LIMITED TO: DRAINAGE, UTILITIES, PAVEMENT, STRIPING, CURB, ETC. REPAIRS SHALL BE EQUAL TO OR BETTER THAN EXISTING CONDITIONS. 2. ALL WORK ON THIS PLAN SHALL BE DONE IN STRICT ACCORDANCE WITH SITE WORK SPECIFICATIONS. 3. CONTRACTOR SHALL COMPLY TO THE FULLEST EXTENT WITH THE LATEST STANDARDS OF OSHA DIRECTIVES OR ANY OTHER AGENCY HAVING JURISDICTION FOR EXCAVATION AND TRENCHING PROCEDURE. CONTRACTOR SHALL USE SUPPORT SYSTEMS, SLOPING, BENCHING, OR OTHER MEANS OF PROTECTION, INCLUDING BUT IS NOT LIMITED TO, ACCESS AND EGRESS FROM ALL EXCAVATION AND TRENCHING. CONTRACTOR IS RESPONSIBLE TO COMPLY WITH PERFORMANCE CRITERIA FOR OSHA.4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING THE PUBLIC DURING CONSTRUCTION, INCLUDING BUT NOT LIMITED TO: CONSTRUCTION FENCING, BARRICADES, SIGNAGE, ETC. 5. CONTRACTOR I S RESPONSIBLE FOR VERIFYING ALL UTILITIES AND NOTIFYING THE APPROPRIATE UTILITY COMPANY PRIOR TO BEGINNING CONSTRUCTION. 6. CONTRACTOR SHALL VERIFY HORIZONTAL AND VERTICAL LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. SCOPE OF WORK REMOVE EXISTING MENU BOARDS PER SITE NOTES. INSTALL NEW MENU BOARDS AND CONNECT TO EXISTING CONDUIT AND WIRING. REFER TO MANUFACTURERS BOARD PUBLISHED INSTALLATION INSTRUCTIONS. BUI LDING CODE SUMMARY APPLICABLE BUILDING CODE: APPLICABLE ELECTRICAL CODE: USE GROUP: BUILDING DEPARTMENT PHONE NO: CALIFORNIA BUILDING CODE 2022, EDITION CALIFORNIA ELECTRIC CODE 2022, EDITION A2 - ASSEMBLY (714) 667-2700 EXISTING SIGNAGE AREA TO BE REMOVED: 32.00 SQ FT NEW SIGNAGE AREA TO BE ADDED: PROJECT ADDRESS: SHEET INDEX C1 .0 - SITE PLAN AND NOTES C1 .1 - ENLARGED UTILITY PLANS S1.0 - MENU BOARD FOUNDATION VICINITY MAP (NTS) 17.80 SQ FT 2701 N. GRAND AVE. SANTA ANA, CA 92705-8751 1 13.7' 1 rq -r- NORTH C, LO rq -r- TWO PANEL MENU BOARD SCREEN= 17.8 SQ FT FRAME = 20.1 SQ FT SIDE VIEW NEW MENU BOARD NOT TO SCALE MENU BOARD 32.00 SQ FT EXISTING SIGNAGE BOARD To BE REMOVED NOT TO SCALE /(I EXISTING BUILDING " I" //' '' ''' '''''' AREA OF WORK_/ - - - - 74'-1" ± FROM MAIN BOARD TO CENTER OF DT WINDOW I''' ''''' ''''' -;�-!- �.:-=��-·-o�-. _O _VE_RA_L _L _SI_T _E _P _LA_N ____ � 0 20' 30' NORTH 0 1� 1S c:: en wCl w Cl c:: RRMM ARCHITECTS COLLABORATIVE, INC. 1317 Executive Blvd, Suite 200 Chesapeake, VA 23320 (757)622-2828 / fax (757)622-6883 DATE _'_J /]<[• I PROJECT DESIGNED DRAWN CHECKED I en wc::ClCl<>:wI­ en 07/24/2024 24500-68 KLS KLS JCW SITE PLAN AND NOTES C1 .0 BLDG # 101121007 APPROVALS BLDG - TLe PLNG - CSantana 2701 N Grand Ave- Sign12/5/2024 2 1 4 4 02 03 04 05 EXISTING BUILDING 5 02 03 04 05 EXISTING BUILDING 4 4 2 3 30° 2'-0" C1.1 ENLARGED UTILITY PLANS SITE PLAN KEY NOTES SITE PLAN LEGEND ENLARGED DEMOLITION PLAN SCALE: 1/4" = 1'-0" ENLARGED SITE PLAN SCALE: 1/4" = 1'-0" NORTHNORTH NEW DOUBLE PANEL OUTDOOR DIGITAL MENU BOARD EXISTING MENU BOARDS TO BE REMOVED 3 PANEL (MB) MENU BOARD 1 EXISTING MENU BOARD / PRE BROWSE TO BE REMOVED. SEE SITE NOTE #3. 2 3 EXISTING DIGITAL ORDER SCREEN WITH SPEAKER TO REMAIN DOUBLE PANEL MENU BOARD. REFER TO STRUCTURAL SHEET FOR FOOTING INFORMATION. EXISTING BOLLARDS (2) TO REMAIN4 CONNECT NEW MB TO EXISTING POWER FROM PREVIOUS BOARDS5 ELECTRICAL PLAN NOTES 1.INTENT OF DESIGN: DISCONNECT POWER AND DATA FEEDS FROM EXISTING MENU BOARDS AND PRE-BROWSE BOARDS (IF APPLICABLE), REMOVE AND DISPOSE. 2.RE-USE EXISTING CIRCUIT FROM EXISTING PANEL DIRECTORY INSERTS, CONTRACTOR TO FIELD VERIFY AND UTILIZE EXISTING BRANCH CIRCUITS FEEDING THE PRIMARY (BRANCH CIRCUIT 1) MENU BOARDS AND SECONDARY (BRANCH CIRCUIT 2) PRE-BROWSE BOARDS. 3.COORDINATE ALL CONDUIT AND CIRCUITING SIZE REQUIREMENTS WITH MANUFACTURERS INSTALL REQUIREMENTS 4.ELECTRICAL SHUT OFF SWITCH - LOCATED ON BACK OF MENU BOARD AND PRE-BROWSE BOARDS. PRE-BROWSE BOARDS MAY NOT BE PART OF THIS SCOPE. REFER TO SCOPE / SITE PLAN. EXISTING DIGITAL ORDER SCREEN W/ SPEAKER RE V DA T E BY DE S C R I P T I O N 1"=10'-0" 0 10'15' FI L E N A M E : C : \ U s e r s \ j w i l s o n \ a p p d a t a \ l o c a l \ t e m p \ A c P u b l i s h _ 2 4 2 4 8 \ 4 5 0 6 8 A _ C 1 _ 1 . d w g L A Y O U T N A M E : W o r k P L O T T E D : T h u r s d a y , J u l y 2 5 , 2 0 2 4 - 3 : 3 9 p m 1"=20'-0" 0 20'30' PROJECT DATE DESIGNED DRAWN CHECKED KLS 24500-68 07/24/2024 JCW SI T E A D D R E S S : 27 0 1 N . G R A N D A V E . SA N T A A N A , C A 9 2 7 0 5 - 8 7 5 1 SC C 5 4 4 4 8 (757)622-2828 / fax (757)622-6883 Chesapeake, VA 23320 1317 Executive Blvd, Suite 200 RRMM® COLLABORATIVE, INC. ARCHITECTS KLS STATE OF CA L IFORNIA L ICENSED A RCHITECT C-33667 MICHAEL L. SMITH RENEWAL DATE 04-30-2025 2701 N Grand Ave- Sign12/5/2024 FOUNDATION SECTION (MENU BOARD) 1" = 1'-0" EXIST. REINF. TO REMAIN FINISH GRADE, COORD. W/ CIVIL DWGS. SIGNAGE FRAME, COORD. W/ SUPPLIER BASE PLATE PROVIDED BY SIGN MANUF. (4) 3 4"Ø ALL-THREAD EPOXY ANCHOR BOLTS W/ HILTI HY200 EPOXY OR APPROVED EQUAL, MIN. EMBED. = 12" INTO EXIST. FOOTING EXIST. CONC. FOOTING TO REMAIN #5 DOWELS EA. SIDE (T&B) W/ HILTI HY200 EPOXY, SEE REINF. PLANS FOR ADDIT. INFO. (TYP.) (1)-#5 CONT. (T&B) REMOVE EXIST. BASE PLATE AND CUT OFF EXIST. ANCHOR BOLTS ABOVE EXIST. CONC. FOOTING (F.V.) ROUGHEN SURFACE AND APPLY BONDING AGENT (TYP.) 4" MIN. SEE TYPICAL CONN. DETAIL SECTION A-A COMPACT SUBGRADE TO 95% DRY DENSITY IN ACCORDANCE W/ ASTM D698 (TYP.) CONCRETE NOTES: 1.ALL FOOTINGS SHALL BEAR ON FIRM UNDISTURBED RESIDUAL SOIL AND/OR EARTH FILL COMPACTED TO 95% OF ITS MAXIMUM DRY DENSITY AS PER ASTM D698 (STANDARD PROCTOR) UNLESS NOTED OTHERWISE. CONTRACTOR SHALL CONFIRM SOIL CAPACITY PRIOR TO CONCRETE PLACEMENT. 2.ALL PIERS TO EXTEND TO FROST DEPTH AS DETERMINED BY LOCAL JURISDICTION. VERIFY WITH LOCAL BUILDING OFFICIAL. 3.TOP OF PIERS SHALL BE SLOPED SUCH THAT MOISTURE CANNOT ACCUMULATE. 4.ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI 301 "STRUCTURAL CONCRETE FOR BUILDINGS" AND ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE." 5.ALL CAST-IN-PLACE CONCRETE SHALL ATTAIN AN ULTIMATE COMPRESSIVE STRENGTH (fc) OF 3000 PSI AT AN AGE OF 28 DAYS UNLESS OTHERWISE NOTED. 6.ALL REINFORCING STEEL SHALL BE ASTM A 615, GRADE 60 DEFORMED BARS, UNLESS OTHERWISE NOTED. 7.CONCRETE PROTECTION FOR REINFORCING AS WELL AS PLACING AND FABRICATION OF REINFORCING SHALL BE IN ACCORDANCE WITH THE "THE AMERICAN CONCRETE INSTITUTE BUILDING CODE REQUIREMENTS" (ACI 318). 8.ALL CAST-IN-PLACE CONCRETE SHALL BE AIR-ENTRAINED TO 6% (±112%). WATER/CEMENT RATIO SHALL NOT EXCEED 0.48. 9.THE MINIMUM CONCRETE COVER FOR THE PROTECTION OF REINFORCEMENT SHALL BE AS NOTED. 10.BEFORE PLACING CONCRETE, ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED, AND MAINTAINED SECURELY IN PLACE. NO "WET SETTING" IS ALLOWED. 11.AGGREGATES IN NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C-33 (HARDROCK). 12.PORTLAND CEMENT SHALL BE TYPE II FOR ALL CONCRETE CONFORMING TO ASTM C150, LOW ALKALI. 13.FLY ASH OR OTHER POZZOLANS CONFORMING TO ASTM C618 CLASS N OR F MAY BE USED AS A PARTIAL SUBSTITUTION FOR PORTLAND CEMENT UP TO A MAXIMUM OF 25% TOTAL CEMENTITIOUS MATERIALS BE WEIGHT IF THE MIX DESIGN IS PROPORTIONED PER ACI318, SECTION 5.3. CONTRACTOR SHALL FORWARD DESIGN MIX TO ARCHITECT AND STRUCTURAL ENGINEER OF RECORD. 14.CONCRETE MIXING OPERATIONS, ETC. SHALL CONFORM TO ASTM C94. 15.DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER USED IN MIX SHALL BE CLEAN AND POTABLE. EXIST. FOOTING, SEE SECTION HEAVY HEX LEVELING NUT (GALV.) (2) HEAVY 3 4" HEX TOP NUT (GALV.) ADHESIVE ANCHOR BOLT DETAIL NOT TO SCALE 2"X2"X14" HEAVY STEEL PLATE WASHERS OR 212"Ø x 14" THK. WASHER (GALV.) 3 4"Ø ALL-THREAD RODS (GALV.) 1' - 5 " NOTE:*DIMENSIONS SHALL BE VERIFIED WITH SIGN FRAME AND BASE PLATE PRIOR TO CONCRETE PLACEMENT. TYPICAL ANCHOR BOLT PATTERN NOT TO SCALE NOTE:IF BOLTS ARE CUT, CONTRACTOR SHALL PROVIDE GALVANIZING SPRAY AT CUT BOLTS TO AVOID RUSTING. TYPICAL SIGN BASE PLATE DETAIL NOT TO SCALE 114" M A X . TIGHTEN TOP NUTS 16 TURN BEYOND HAND-TIGHT (TURN OF NUT METHOD) (MIN 60°, MAX 80°) NOTE:THE DISTANCE FROM THE TOP OF THE FOUNDATION TO THE BOTTOM OF THE BASE PLATE SHALL BE NO GREATER THAN 114". 60° TYPICAL CONNECTION DETAIL NOT TO SCALE FLAT WASHERS 5" P R O J E C T I O N 4" MIN. 1' - 0 " EM B E D . STEEL NOTES: 1.REINFORCEMENT: GRADE 60. 2.ANCHOR RODS, NUTS, AND WASHERS SHALL BE SHIPPED AS AN ASSEMBLY FROM THE SIGN/LIGHTING MANUFACTURER. COORDINATE WITH MANUFACTURER. A. THREADED RODS: ASTM F1554, GRADE 36 B. PLATE WASHERS: ASTM A-36 C. WASHERS: ASTM F-436 D. NUTS: A563DH OR A194-2H 3.ALL HARDWARE SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A-123, HOT-DIP GALVANIZED, ZINC PLATED OR MECHANICALLY GALVANIZED. 4.ANCHOR BOLTS TO BE SET IN ACCORDANCE WITH AISC CODE OF STANDARD PRACTICE. 5.FIELD HEATING TO BEND STEEL SHALL NOT BE ALLOWED. 6.ANCHOR BOLTS TO BE CUT, IF NEEDED, TO 312". APPLY COLD GALVANIZING TO CUT BOLT ENDS. 7.CONTRACTOR (INSTALLER) IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION IN REGARDS TO JOBSITE SAFETY. 8.STRUCTURAL SIGN FRAME AND BASE PLATE DETAILS ARE PROVIDED BY SIGN MANUFACTURER. COORDINATE ALL ATTACHMENTS OF SIGN WITH MANUFACTURER. REFER TO SIGN MANUFACTURER DRAWINGS AND INSTRUCTIONS FOR ADDITIONAL INFORMATION. 9.DO NOT CUT ANCHOR BOLTS OR RODS AFTER INSTALLATION OF FRAME. GENERAL NOTES: 1.THE FOLLOWING CODES WERE USED IN DESIGN: 2022 CALIFORNIA BUILDING STANDARDS CODE (TITLE 24, PART 2), IBC 201 AND ASCE-7 (2016). 2.STRUCTURAL LOADINGS: WIND: WIND (3 SECOND GUST)...........................................VULT = 100MPH VASD = 78 MPH EXPOSURE...........................................................................C RISK CATEGORY.................................................................II WIND BASE SHEAR.......................................................Vb = 690 LBS (MENU BOARD) SEISMIC: SEISMIC IMPORTANCE FACTOR (Ie).................................1.0 MAPPED SPECTRAL RESPONSE ACCELERATIONS..Ss.......1.293g S1........0.461g DESIGN SPECTRAL RESPONSE ACCELERATIONS SDS......1.034g SD1......0.565g SITE CLASS...........................................................................D SEISMIC DESIGN CATEGORY.............................................D SEISMIC RESPONSE COEFFICIENT (CS)..............................0.296 COMPONENT RESPONSE MODIFICATION FACTOR (RP)..3.5 SEISMIC DESIGN FORCE (FP)..............................................0.22 KIPS (MENU BOARD) FROST DEPTH...............................................................................0'-6" 3.ALL FOOTING EXCAVATIONS ARE TO BE CLEAR OF WATER AND FOREIGN MATTER BEFORE PLACING CONCRETE. 4.PRESUMPTIVE MINIMUM ALLOWABLE LATERAL SOIL BEARING PRESSURE (So) OF 100 PSF. CONTRACTOR SHALL CONFIRM AN ALLOWABLE BEARING PRESSURE (Sb) OF 1500 PSF. ALLOWABLE BEARING PRESSURE SHALL BE VERIFIED BY CONTRACTOR PRIOR TO CONCRETE PLACEMENT. 5.FOUNDATION SHALL NOT BE PLACED ON OR AT THE TOP OF A SLOPE EXCEEDING 3:1 WITHOUT EVALUATION BY A PROFESSIONAL LICENSED IN THAT STATE. DO NOT PLACE FOUNDATION IN FILL MATERIAL. 6.DEPTH OF PIER FOUNDATIONS MAY BE LOWERED IF NEEDED TO OBTAIN LOCAL FROST DEPTH ELEVATIONS OR IF REQUIRED DUE TO POOR SOIL CONDITIONS. VERIFY FROST DEPTH ELEVATIONS WITH LOCAL CODE OFFICIAL. 7.ELECTRICAL CONTRACTOR TO PROVIDE INFORMATION ON CONDUIT AND ELECTRICAL REQUIREMENTS AND CONTRACTOR (INSTALLER) SHALL COORDINATE PLACEMENT TO MAINTAIN 2" CLEAR TO ANCHOR BOLTS. 8.COORDINATE LOCATIONS OF SIGNS AND FOUNDATIONS WITH SITE PLAN. 9.CONTRACTOR SHALL CUT EXCESS SONOTUBE FROM AROUND THE PERIMETER OF THE PIER FOUNDATION AFTER PLACEMENT OF BOARD (PRIOR TO LEAVING SITE). 10.CONTRACTOR SHALL NOT DEVIATE FROM STRUCTURAL DRAWING WITHOUT PRIOR WRITTEN CONSENT AND INSTRUCTIONS REGARDING ANY CHANGE TO THE CONTRACT DRAWINGS. ANY DEVIATION FROM THIS DESIGN OR FROM ANY PART OF THIS DRAWING WITHOUT PRIOR WRITTEN CONSENT OF THIS ENGINEER SHALL VOID ALL LIABILITY ASSOCIATED WITH THIS WORK. 11.SPECIAL INSPECTIONS ARE NOT REQUIRED FOR THESE SIGN FOUNDATIONS. 3'-3"± MATCH EXIST. EXIST. CONC. FOOTING TO REMAIN (F.V. SIZE AND DEPTH) (3)-#5 DOWELS EA. SIDE (4" MIN. EMBED.) W/ HILTI HY200 EPOXY (TYP.) (1)-#5 CONT. (T&B) TOP AND BOTT. REINFORCING A A SIGN ORIENTATION ABOVE 2' - 6 " M I N . NOTE:COORDINATE CONDUIT PLACEMENT INSIDE SIGN BASE PRIOR TO CONCRETE PLACEMENT. 5 8" STEEL BASE PLATE PER MANUF. (4) SLOTTED BOLT HOLES (COORD. W/ SIGN PROVIDER) 8" EQ EQ 8" EQ EQ1' - 0 12" 1'-214" 8" 8" 4' - 1 5 8" 5' - 1 1 5 8" 1' - 1 0 " 2'-6" MIN. 4'-10" 2' - 0 " M I N . 1 S1.0 MENU BOARD FOUNDATION FI L E N A M E : N : \ _ S i g n F o u n d a t i o n s \ S t a r b u c k s \ 2 0 2 4 - 4 0 1 5 \ D W G \ S t r u c t S S C 5 4 4 4 8 , S a n t a A n a , C A . d w g L A Y O U T N A M E : H a m m e r h e a d P L O T T E D : T u e s d a y , O c t o b e r 2 2 , 2 0 2 4 - 9 : 4 4 a m structural engineer 508 Baylor Court Suite C Chesapeake, Virginia 23320 757.436.2070 757.436.0610 www.broylesandassociates.com Robert S. Whitaker, PE, SE REG ISTERED PROFESS IONAL ENGINEER STATE OF CAL IFORNIACIVIL R OBERT S . W HITAKER NO. 93116 RE V DA T E BY DE S C R I P T I O N BJ B RE V I E W C O M M E N T S 10 / 2 2 / 2 0 2 4 PROJECT DATE DESIGNED DRAWN CHECKED WPH 24500-68 07/25/2024 RSW 1 SI T E A D D R E S S : 27 0 1 N . G R A N D A V E . SA N T A A N A , C A 9 2 7 0 5 - 8 7 5 1 SS C 5 4 4 4 8 (757)622-2828 / fax (757)622-6883 Chesapeake, VA 23320 1317 Executive Blvd, Suite 200 RRMM ® COLLABORATIVE, INC. ARCHITECTS WPH 2701 N Grand Ave- Sign12/5/2024 508 Baylor Court, Suite C Chesapeake, VA 23220 757.436.2070 Charles Town, WV 304.370.3088 Prepared by: Broyles and Associates, P.C. 508 Baylor Ct, Suite C Chesapeake, VA 23220 757.436.2070 • 304.370.3088 • dbroyles@broylesandassociates.com • www.broylesandassociates.com STRUCTURAL CALCULATIONS COVER SHEET Starbucks Menu Board Foundations Santa Ana, CA Foundation Calculations July 24, 2024 Prepared for: RRMM 1317 Executive Blvd, Chesapeake, VA 23320 2701 N Grand Ave- Sign12/5/2024 Broyles And Associates 508 Baylor Court, Suite C Chesapeake, Virgnia 23320 PH: 757-436-2070 Project Starbucks Job Ref. Section 115 MPH Sign Foundation Design Sheet no./rev. 1 Calc. by RSW Date 2021/30/2024 4 Chk'd by Date App'd by Date DESIGN CRITERIA – ASCE 7-16 Wind Design Wind Speed V = 115 MPH Risk Category II Exposure Category C Foundation Design Presumptive Soil Bearing Q = 1500 psf Concrete Strength fc = 3000 psi Concrete anchors ASTM F1554 A36 fy = 36 ksi Dimensional Information Overall Sign Height (both) h = 6.0 ft Single Menu Board: Sign Height hs = 4.17 ft Sign Width bs = 2.5 ft Height of Centerline hsc = h - hs/2 = 4.0 ft Double Menu Board: Sign Height hd = 4.17 ft Sign Width bd = 4.83 ft Height of Centerline hdc = h - hd/2 = 4.0 ft Embedment calculation uses ASD loads = 0.6* Ult = 370# * 0.6 = 222# WIND LOADING DOUBLE MENU BOARD (ASCE7-16) WIND LOADING In accordance with ASCE7-16 Using the directional design method Tedds calculation version 2.1.13 Wall/sign data Length of wall/sign B = 4.83 ft Height of wall/sign s = 4.17 ft Height to top of sign h = 6.00 ft General wind load requirements Basic wind speed V = 115.0 mph Risk category II Velocity pressure exponent coef (Table 26.6-1) Kd = 0.85 Ground elevation above sea level zgl = 0 ft Ground elevation factor Ke = exp(-0.0000362  zgl/1ft) = 1.00 Exposure category (cl 26.7.3) C 2701 N Grand Ave- Sign12/5/2024 Broyles And Associates 508 Baylor Court, Suite C Chesapeake, Virgnia 23320 PH: 757-436-2070 Project Starbucks Job Ref. Section 115 MPH Sign Foundation Design Sheet no./rev. 2 Calc. by RSW Date 2021/30/2024 4 Chk'd by Date App'd by Date Gust effect factor Gf = 0.85 Minimum design wind loading (cl.27.1.5) pmin_r = 8 lb/ft2 Topography Topography factor not significant Kzt = 1.0 Velocity pressure Velocity pressure coefficient (Table 26.10-1) Kz = 0.85 Velocity pressure qh = 0.00256  Kz  Kzt  Kd  Ke  V2  1psf/mph2 = 24.5 psf Area of sign Af = B  s = 20.141 ft2 Ratio of solid area to gross area  = 1.00 Wall/sign forces – Case A and B Force coefficient (Figure 29.3-1) Cf_A = 1.64 Resultant force FA = max(16psf, qh  Gf  Cf_A)  Af = 0.7 kips Embedment calculation uses ASD loads = 0.6* Ult = 690# * 0.6 = 414# 2701 N Grand Ave- Sign12/5/2024 Project:Sign Designs Proj No: Prepared By:RSW Date:7/24/24 Checked By: Sheet No: Subject: ASCE 7 Wind Loads Last updated:01/30/24 Directional Procedure Square Footing Loading (at top of ftg) Vol. of conc.:16.3 ft^3 V ULT=690 # (at center) w conc=150 pcf V = 0.6 VULT=414 # (at center)165.6 f'c=3000 psi P =300 # (at center)120.0 fy=60000 psi M =1656 ft-# (at center)662.4 e =0 in Soil Sign Base Steel k=90 pci Modulus of Subgrade reaction 12 ''x 14" baseplate Soil angle:30 0.524 rad Soil weight:110 pcf Footing W min = Pwall/ Qnet = 0.08ft Q-net allow:1500 psf net allowable bearing Ftg width:3.250 2.500 Soil depth abv:0 in Ftg depth:24 in Weight:0 plf Weight:975 plf Cover to ties:3''As tie=0.028 in^2 Increase Soil Bearing Pressure?d=20.8125''0.028 Use soil wt?in Q-net 0 As min long= 1.685 in^2 Soil weight:0 # (per foot) Use ftg wt?yes 1 Ftg weight:975 # (per foot) P tot design=1095.0 # (per foot)MRESIST = 5783.1ft-#MOT= 3229.2 ft-# e=M/P tot=0.60 ft (outside kern)MRESIST = 1779.4ft-# / ft MOT= 993.6 ft-# e > b/6=0.54 :. Q=4/3*P/(L(B-2*e)) Qmax=712 psf < 1800 psf gross +/- Qmin=0 psf 1800 Assuming soil resulantant is located at "e" Soil load width x=3(B/2-e)=36.9 Overturning and Sliding Use soil wt?yes 1 Soil weight:0 # (per foot) Use ftg wt?yes 1 Ftg weight:975 # (per foot)Footing Design Load factor=1.4 P tot Design=1095.0 # (per foot)Bending:Lcr =13.5''from edge of ftg 3558.8 # total M pressure=396 ft-# Slide frict=296 # friction Mu=1.4*Mp=554 ft-# tan(o/2)=0.27 Shear:Lcr =0''from edge of ftg Slide soil=0 # side soil V pressure=0 # S Resist Total=296 # / ft length Vu=1.4*Vp=0 # Slide FS =1.79 > 1.25 M resist=P tot*(width/2)=5783.1 ft-#Reinforced Footing Design: =1779.4 ft-# / ft ФMoment =0.9 ФShear =0.75 OT FS =1.79 > 1.25 Transverse ties:# 3 at 48'' oc a=0.055 As tie=0.028 in^2 Unreinforced Footing Design:Ф =0.55 c=0.065 < 0.375*d=7.805 ФMn=Ф*5sqrt(f'c)(b*d^2/6)=10874 ft-# > 554ft-#ФMn=Ф*As*fy*(d-a/2)=2619 ft-# > 554ft-# ФVn=Ф*4/3*sqrt(f'c)*b*h=11568 # > 0#ФVn=Ф*2*sqrt(f'c)*b*d=20519 # > 0# 0 3.25 ft x 2.5 ft x 24'' column footing is acceptable as an unreinforced footing. Orig. size = 39''x 19''x 24'' | | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| |E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E 0 13.5 0 712 452 712 13.5'' 0'' M P V 1213.5 24 0 /ft /ft /ft /ft ft x ft 36.9 NWIND 2701 N Grand Ave- Sign12/5/2024 Broyles And Associates 508 Baylor Court, Suite C Chesapeake, Virgnia 23320 PH: 757-436-2070 Project Starbucks Job Ref. Section 115 MPH Sign Foundation Design Sheet no./rev. 8 Calc. by RSW Date 2021/30/2024 4 Chk'd by Date App'd by Date POST INSTALLED ANCHORS AT MENU BOARD (PRE-SELL BOARD SIMILAR) ANCHOR BOLT DESIGN In accordance with ACI318-14 Tedds calculation version 2.1.08 Design summary Description Unit Required Provided Util. Result Anchor tensile strength (kips) 2.10 18.70 0.112 PASS Concrete breakout (kips) 4.20 6.98 0.601 PASS Bond strength (kips) 4.20 6.06 0.693 PASS Anchor shear strength (kips) 0.70 9.07 0.077 PASS Shear breakout (rear) (kips) 0.70 8.70 0.081 PASS Side shear breakout (rear) (kips) 0.70 22.13 0.032 PASS Anchor pryout (kips) 0.70 15.09 0.046 PASS Interaction of forces 1.200 0.773 0.645 PASS Anchor bolt geometry Anchor bolt Proprietary bolt Diameter of anchor bolt da = 0.75 in Number of bolts in x direction Nboltx = 2 Number of bolts in y direction Nbolty = 2 Total number of bolts ntotal = 4 Total No. of bolts in tension ntens = 2 Spacing of bolts in x direction sboltx = 8 in Spacing of bolts in y direction sbolty = 8 in Effective area of anchor Ase = 0.43 in2 Embed. depth of anchor bolt hef = 12 in Foundation geometry Member thickness ha = 36 in CL baseplate - left edge xce1 = 10 in CL baseplate - right edge xce2 = 10 in CL baseplate - bot. edge yce1 = 10 in CL baseplate - top edge yce2 = 10 in Material details Nom. tensile stress of steel futa = 58 ksi Compressive strength of conc f’c = 3 ksi Concrete modification factor  = 1.00 Mod. factor, concrete failure a = 1.00 Mod. factor, adhesive bond a1 = 1.00 Strength reduction factors Tension of steel element t,s = 0.75 Shear of steel element v,s = 0.65 Concrete tension t,c = 0.75 Concrete shear v,c = 0.75 Concrete tension for pullout t,cB = 0.70 Concrete shear for pryout v,cB = 0.70 Seismic requirements Seismic category D Attachment undergoes ductile yielding - the attachment (not covered in this calculation) will undergo ductile yielding at a force level corresponding to anchor forces no greater than the calculated design strength of the anchors. Anchor tensile strengths associated with concrete failure modes will be taken to be 0.75 times the calculated strength. Anchor forces No. of bolt rows in tension NboltN = 1 Axial force in bolts for row 1 N1 = 4.20 kips Total axial force on bolt group NR = 4.20 kips Max axial force to single bolt Nmax,s = 2.10 kips Eccentricity of axial load e’N = 0.00 in Shear force to bolt group V = 0.70 kips 2701 N Grand Ave- Sign12/5/2024 Broyles And Associates 508 Baylor Court, Suite C Chesapeake, Virgnia 23320 PH: 757-436-2070 Project Starbucks Job Ref. Section 115 MPH Sign Foundation Design Sheet no./rev. 9 Calc. by RSW Date 2021/30/2024 4 Chk'd by Date App'd by Date Steel strength of anchor in tension (17.4.1) Nom strength of anchor Nsa = 24.94 kips Steel strength of anchor Nsa = 18.70 kips PASS - Steel strength of anchor exceeds max tension in single bolt Check concrete breakout strength of anchor bolt in tension (17.4.2) The anchors are located at less than 1.5hef from 4 edges. Therefore the effective embedded depth has to be limited to 4.00" in accordance with 17.4.2.3 Limiting embedded depth hef,lim = 4.00 in Coeff for basic breakout kc = 17 Breakout strgth single anchor Nb = 7.45 kips Proj area - groups of anchors ANc = 240.00 in2 Proj area - single anchor ANco = 144.00 in2 Min dist to edge of concrete ca,min = 6.00 in Ecc. mod factor for groups ec,N = 1.00 Mod factor for edge effects ed,N = 1.00 Mod factor for no cracking c,N = 1.000 Mod factor for cracked conc cp,N = 1.000 Nom conc breakout strength Ncbg = 12.42 kips Concrete breakout strength Ncbg = 6.98 kips PASS - Breakout strength exceeds tension in bolts 2701 N Grand Ave- Sign12/5/2024 Broyles And Associates 508 Baylor Court, Suite C Chesapeake, Virgnia 23320 PH: 757-436-2070 Project Starbucks Job Ref. Section 115 MPH Sign Foundation Design Sheet no./rev. 10 Calc. by RSW Date 2021/30/2024 4 Chk'd by Date App'd by Date Bond strength of adhesive anchor in tension (17.4.5) Anchor is not subject to sustained tension loading Stength reduction factor t = 0.65 Char. bond stress of anchor cr =225 psi Uncracked bond stress anchor uncr = 650 psi Dist to develop full bond str. cNa = 5.77 in Basic bond str. single anchor Nba = 6.36 kips Proj area of anchors ANa = 225.2 in2 Full proj area - single anchor ANao = 132.95 in2 Min dist to edge of concrete ca,min = 6 in Ecc. mod factor for groups ec,Na = 1.000 Mod factor for edge effects ed,Na = 1.000 Mod factor for no cracking cp,Na = 1.000 Nom bond strength in tension Nag = 10.78 kips Bond strength in tension Nag = 6.06 kips PASS - Bond strength exceeds tension in bolts Steel strength of anchor in shear (17.5.1) Nom strength of anchor Vsa = 13.95 kips Steel strength of anchor Vsa = 9.07 kips PASS - Steel strength of anchor exceeds shear in bolts 2701 N Grand Ave- Sign12/5/2024 Broyles And Associates 508 Baylor Court, Suite C Chesapeake, Virgnia 23320 PH: 757-436-2070 Project Starbucks Job Ref. Section 115 MPH Sign Foundation Design Sheet no./rev. 11 Calc. by RSW Date 2021/30/2024 4 Chk'd by Date App'd by Date Concrete breakout strength in shear perpendicular to edge - Case 2. All shear resisted by rear bolts (17.5.2) Applied shear Vapp = 0.35 kips Edge dist x near corner ca1 = 14.00 in Edge dist y near corner ca2 = 6.00 in Load bearing length of anchor le = 6 in Basic conc breakout strength Vb = 25.82 kips Proj area - single anchor AVco = 882.00 in2 Proj area - group of anchors AVc = 420.00 in2 Mod factor for edge effect ed.V = 0.9 Eccentricity of loading e’V = 0.00 in Mod factor of eccentricity ec,V = 1.00 Mod factor for cracking c,V = 1.2 Mod factor for edge distance h,V = 1.0 Nom conc breakout strength Vcbg = 11.59 kips Conc break out strength Vcbg = 8.70 kips PASS - Shear breakout perpendicular to edge strength exceeds shear in bolts 2701 N Grand Ave- Sign12/5/2024 Broyles And Associates 508 Baylor Court, Suite C Chesapeake, Virgnia 23320 PH: 757-436-2070 Project Starbucks Job Ref. Section 115 MPH Sign Foundation Design Sheet no./rev. 12 Calc. by RSW Date 2021/30/2024 4 Chk'd by Date App'd by Date Concrete breakout strength in shear - Case 1. Half of shear resisted by front bolts (17.5.2) Applied shear Vapp = 0.35 kips Edge dist x near corner ca1 = 6.00 in Edge dist y near corner ca2 = 6.00 in Load bearing length of anchor le = 6 in Basic conc breakout strength Vb = 7.24 kips Proj area - single anchor AVco = 162.00 in2 Proj area - group of anchors AVc = 180.00 in2 Mod factor for edge effect ed.V = 0.9 Eccentricity of loading e’V = 0.00 in Mod factor of eccentricity ec,V = 1.00 Mod factor for cracking c,V = 1.2 Mod factor for edge distance h,V = 1.0 Nom conc breakout strength Vcbg = 8.69 kips Conc break out strength Vcbg = 6.52 kips PASS - Shear breakout perpendicular to edge strength exceeds shear in bolts 2701 N Grand Ave- Sign12/5/2024 Broyles And Associates 508 Baylor Court, Suite C Chesapeake, Virgnia 23320 PH: 757-436-2070 Project Starbucks Job Ref. Section 115 MPH Sign Foundation Design Sheet no./rev. 13 Calc. by RSW Date 2021/30/2024 4 Chk'd by Date App'd by Date Concrete breakout strength in shear parallel to edge - Case 2. All shear resisted by rear bolts ( parallel to edge - Case 2. All shear resisted by rear bolts) Applied shear Vapp = 0.35 kips Edge distance x for shear ca1,p = 14 in Edge distance y for shear ca2,p = 6 in Load bearing length of anchor le = 6 in Basic conc breakout strength Vb,p = 25.82 kips Proj area of single anchor AVco,p = 882 in2 Proj area of group of anchors AVc,p = 420 in2 Mod factor for edge effect ed,V,p = 1.000 Eccentricity of loading e’V,p = 0 in Mod factor of eccentric load ec,V,p = 1.000 Mod factor for cracking c,V = 1.200 Mod factor for edge distance h,V,p = 1.000 Nom breakout strength shear Vcbg,p = 29.51 kips Concbreak out strength shear Vcbg,p = 22.13 kips PASS - Shear breakout strength parallel to edge exceeds shear in bolts 2701 N Grand Ave- Sign12/5/2024 Broyles And Associates 508 Baylor Court, Suite C Chesapeake, Virgnia 23320 PH: 757-436-2070 Project Starbucks Job Ref. Section 115 MPH Sign Foundation Design Sheet no./rev. 14 Calc. by RSW Date 2021/30/2024 4 Chk'd by Date App'd by Date Concrete breakout strength in shear parallel to edge - Case 1. Half of shear resisted by front bolts ( parallel to edge - Case 1. Half of shear resisted by front bolts) Applied shear Vapp = 0.35 kips Edge distance x for shear ca1,p = 6 in Edge distance y for shear ca2,p = 6 in Load bearing length of anchor le = 6 in Basic conc breakout strength Vb,p = 7.24 kips Proj area of single anchor AVco,p = 162 in2 Proj area of group of anchors AVc,p = 180 in2 Mod factor for edge effect ed,V,p = 1.000 Eccentricity of loading e’V,p = 0 in Mod factor of eccentric load ec,V,p = 1.000 Mod factor for cracking c,V = 1.200 Mod factor for edge distance h,V,p = 1.000 Nom breakout strength shear Vcbg,p = 19.32 kips Concbreak out strength shear Vcbg,p = 14.49 kips PASS - Shear breakout strength parallel to edge exceeds shear in bolts Pryout strength of anchor in shear (17.5.3) Coefficient of pryout strength kcp = 2.0 Nom pryout strength of anchor Vcpg = 21.55 kips Pryout strength of anchor Vcpg = 15.09 kips PASS - Pryout strength of anchor exceeds shear in bolts Interaction of tensile and shear forces Crit design strength tension Nn = 6.06 kips Crit applied tensile force Nua = 4.20 kips Crit design strength shear Vn = 8.70 kips Crit applied shear force Vua = 0.70 kips Nua / Nn = 0.693 Vua / Vn = 0.081 As Vua / Vn <= 0.2,Full strength in tension is permitted Pass - Applied tension is less than tension capacity 2701 N Grand Ave- Sign12/5/2024