Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2425 W Bobby Ln - Plan
To Whom it May Concern, Property Owner Name ADDRESS:___2425 bobby lane, Santa Ana, CA 92706 ______________________________________ ____________Ramon Salgado____________________ Print Name Better Earth Electric Inc. 1815 E Wilshire Ave. St., 908/909, Santa Ana CA 92705 888-373-9379 SantaAnaPermits@Betterearth.solar J Ramon Salgado, the owner of the property located at, Date__9/05/2024 I Have hired, Better Earth Electric Inc, State Lic #1024460, to install a PV Solar System: _________Installation of a 7 module solar PV system with 1 INVERTER. System size is 2.800 KWP + 1 ENPHASE IQ BATTERY 5P - 5kWh +(N) 125A SUB PANEL_________________________________________________________ __________________________________________________________________ Kind Regards , ________________________________ 2425 W Bobby Ln 10/21/2024 Certificate Of Completion Envelope Id: 0ED6109A8010406CAEC1A798F16E9DE0 Status: Completed Subject: EverBright EverFixed Plus Direct Pay - Customer Agreement for Ramon Salgado Vargas... Source Envelope: Document Pages: 69 Signatures: 7 Envelope Originator: Certificate Pages: 5 Initials: 35 EverBright Financing AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) Admin@goeverbright.com IP Address: 34.193.243.170 Record Tracking Status: Original 8/4/2024 3:19:40 PM Holder: EverBright Financing Admin@goeverbright.com Location: DocuSign Status: Authoritative Copy (1 of 5 documents) 8/5/2024 8:56:24 AM Holder: EverBright Financing Admin@goeverbright.com Location: DocuSign Signer Events Signature Timestamp Ramon Salgado Vargas Salgador52@gmail.com Security Level: Email, Account Authentication (None), Authentication Signature Adoption: Pre-selected Style Using IP Address: 97.190.77.28 Signed using mobile Sent: 8/4/2024 3:19:45 PM Viewed: 8/4/2024 3:28:38 PM Signed: 8/4/2024 3:32:57 PM Authentication Details ID Check: Transaction: 31031196999105 Result: passed Vendor ID: LexisNexis Type: iAuth Recipient Name Provided by: Recipient Information Provided for ID Check: Address, DOB Performed: 8/4/2024 3:27:49 PM Question Details: failed person.city.real failed person.state.real passed property.purchasedwhen.real passed vehicle.association.fake passed person.city.real passed property.association.single.real Electronic Record and Signature Disclosure: Accepted: 8/4/2024 3:28:38 PM ID: 59c2c4f0-d811-44a9-8171-9026d890e28d Simon Spielberger simon.spielberger@betterearth.solar Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 172.58.130.253 Signed using mobile Sent: 8/4/2024 3:33:01 PM Viewed: 8/4/2024 3:42:59 PM Signed: 8/4/2024 3:43:18 PM Electronic Record and Signature Disclosure: Accepted: 8/4/2024 3:42:59 PM ID: 7b996f3e-fde6-4c10-b75c-a7c761dad140 Shaun Sharabi projectreview@betterearth.solar Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 207.244.169.112 Sent: 8/4/2024 3:43:22 PM Viewed: 8/5/2024 8:56:07 AM Signed: 8/5/2024 8:56:20 AM Electronic Record and Signature Disclosure: Accepted: 8/5/2024 8:56:07 AM ID: 18ba3bd9-91b7-411f-8d77-f57f048493f9 In Person Signer Events Signature Timestamp 2425 W Bobby Ln 10/21/2024 Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 8/4/2024 3:19:45 PM Certified Delivered Security Checked 8/5/2024 8:56:07 AM Signing Complete Security Checked 8/5/2024 8:56:20 AM Completed Security Checked 8/5/2024 8:56:20 AM Payment Events Status Timestamps Electronic Record and Signature Disclosure 2425 W Bobby Ln 10/21/2024 ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, EverBright, LLC (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to this Electronic Record and Signature Disclosure (ERSD), please confirm your agreement by selecting the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after the signing session and, if you elect to create a DocuSign account, you may access the documents for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. Further, you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Electronic Record and Signature Disclosure created on: 8/3/2023 12:33:18 PM Parties agreed to: Ramon Salgado Vargas, Simon Spielberger, Shaun Sharabi 2425 W Bobby Ln 10/21/2024 Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. How to contact EverBright, LLC: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: support@myeverbright.com To advise EverBright, LLC of your new email address To let us know of a change in your email address where we should send notices and disclosures electronically to you, you must send an email message to us at support@myeverbright.com and in the body of such request you must state: your previous email address, your new email address. We do not require any other information from you to change your email address. If you created a DocuSign account, you may update it with your new email address through your account preferences. To request paper copies from EverBright, LLC To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an email to support@myeverbright.com and in the body of such request you must state your email address, full name, mailing address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with EverBright, LLC To inform us that you no longer wish to receive future notices and disclosures in electronic format you may: 2425 W Bobby Ln 10/21/2024 i. decline to sign a document from within your signing session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an email to support@myeverbright.com and in the body of such request you must state your email, full name, mailing address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found here: https://support.docusign.com/guides/signer-guide- signing-system-requirements. Acknowledging your access and consent to receive and sign documents electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please confirm that you have read this ERSD, and (i) that you are able to print on paper or electronically save this ERSD for your future reference and access; or (ii) that you are able to email this ERSD to an email address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format as described herein, then select the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. By selecting the check-box next to ‘I agree to use electronic records and signatures’, you confirm that: You can access and read this Electronic Record and Signature Disclosure; and You can print on paper this Electronic Record and Signature Disclosure, or save or send this Electronic Record and Disclosure to a location where you can print it, for future reference and access; and Until or unless you notify EverBright, LLC as described above, you consent to receive exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you by EverBright, LLC during the course of your relationship with EverBright, LLC. 2425 W Bobby Ln 10/21/2024 BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 2800W DC / 2030W AC Ramon Salgado 2425 Bobby Lane, Santa Ana, CA 92706 APN: 39914106 DATE: 8/28/2024 TIME: 07:52 PM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE: COVER SHEET 001 CS JURISDICTION STAMPS ADDITIONAL SCOPE OF WORK MAIN PANEL UPGRADE: N/A DERATE MAIN BREAKER: (N) 175A EV CHARGER: N/A LOCATION: OUTDOORS ON EXTERIOR WALL ESS: (1) ENPHASE IQ BATTERY 5P AT 13.5kWh EACH BATTERY TO BE INSTALLED AT LEAST 3' FROM WINDOWS, DOORS, VENTS, AND GAS. ESS IS NOT SUBJECT TO VEHICLE IMPACT. UPSIZE MAIN BREAKER: N/A INSTALLER NOTES: PROPERTY INFORMATION OWNER: RAMON SALGADO PHONE: 1714-309-8800 EMAIL: salgador52@gmail.com CONTRACTOR: BETTER EARTH ELECTRIC INC. PHONE: (888) 373-9379 AUTHORITIES HAVING JURISDICTION BUILDING: SANTA ANA (CA) UTILITY: SOUTHERN CALIFORNIA EDISON DESIGN SPECIFICATIONS OCCUPANCY: R-3/U CONSTRUCTION: V-B NAME: RESIDENTIAL SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 100 MPH ROOF SURFACE: 2498 SQ FT (N) PV SQ FOOTAGE: 147.2 SQ FT (E) PV SQ FOOTAGE: 236.7 SQ FT TOTAL PV SQ FOOTAGE: 383.9 SQ FT PV COVERAGE: 15.4 % WEIGHT OF EQUIPMENT: 333.8 LBS WEIGHT PER ATTACHMENT: 15.17 LBS DISTRIBUTED WEIGHT: 2.27 PSF NO. OF STORIES: 1 FIRE SPRINKLERS: NO LOT INFORMATION APN: 39914106 LOT AREA: 7139 LIVING AREA: 1283 SCOPE OF WORK MODULE INFORTMATION MODULE QTY: 7 MODULE MFG: LONGI MODULE MODEL: LR5-54HABB-400M ENERGY STORAGE SYSTEM INFORMATION STORAGE QTY: 1 STORAGE MFG: ENPHASE STORAGE MODEL: IQ BATTERY 5P - 5kWh RAILING INFORMATION RAILING MFG: UNIRAC RAILING MODEL: UNIRAC SM LIGHT INVERTER INFORMATION INVERTER QTY: 7 INVERTER MFG: ENPHASE INVERTER MODEL: IQ8PLUS-72-2-US TABLE OF CONTENTS PAGE NUMBER PAGE TITLE 001 CS COVER SHEET 002 NS1 NOTES SHEET 003 SP1 SITE PLAN 004 RP1 ROOF PLAN 005 RF1 RACKING & FRAMING 006 LD1 LINE DIAGRAM 007 PP1 LABELS & PLACARD 008 OM1 OPTIMIZER MAP 009 JH1 JOB HAZARD ANALYSIS 010 EL1 ELEC. LOAD CALCS SS SPECIFICATION PAGES EXISTING SOLAR INFORMATION MODULE QTY: 13 MODULE MFG & MODEL:SOLARWORLD SW 280 INVERTER QTY: 13 INVERTER MFG & MODEL:ENPHASE M250 MOUNTING INFORTMATION MOUNT QTY: 22 MOUNT MFG & MODEL:UNIRAC FLASHLOC - MILL COMBINER INFORMATION COMBINER QTY: 1 COMBINER MFG: ENPHASE COMBINER MODEL: IQ COMBINER 5C Ramon Salgado 2425 Bobby Lane, Santa Ana, CA 92706 APN: 39914106 (N) SYSTEM SIZE: 2800 DC (E) SYSTEM SIZE: 3640 DC (N) SYSTEM SIZE: 2030 AC (E) SYSTEM SIZE: 3120 AC COMBINED SYSTEM SIZE 4830 DC / 6760 AC 26 This item has been digitally signed and sealed on Sep 23, 2024 **The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. ** Bldg#: 101120970 Elec#: 20184081 Approvals: Elec: M Smith 2425 W Bobby Ln 10/21/2024 NOTES SHEET 002 NS1 JURISDICTION NOTES ELECTRICAL NOTES CONSTRUCTION NOTES UTILITY NOTES 1. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. 3. ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4. THE SOLAR INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING OR MECHANICAL VENTS. 5. A LADDER WILL BE IN PLACE FOR INSPECTIONS IN COMPLIANCE WITH OSHA REGULATIONS. 6. MODULE MOUNTING STRUCTURE WILL BE TIED DIRECTLY INTO STRUCTURAL ELEMENTS OF SINGLE FAMILY DWELLING ROOF TRUSSES / RAFTERS OR BEAMS ACCORDING TO MOUNTING STRUCTURE DIRECTIONS. 7. ROOF COVERING PENETRATIONS SHALL BE DESIGNED, INSTALLED AND MAINTAINED IN ACCORDANCE WITH BUILDING CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGS SHALL SERVE TO PROTECT THE BUILDING STRUCTURE. 8. CONDUIT, WIRING SYSTEMS, AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY. THIS EQUIPMENT SHALL ALSO BE LOCATED AS CLOSE AS POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. 9. MODULES MUST HAVE 6" CLEARANCE FROM ALL VENTS AND OBSTRUCTIONS. CODE REFERENCES GENERAL NOTES 1. RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURES SPECIFICATIONS AND THE 2022 CALIFORNIA RESIDENTIAL CODE, SECTIONS R314, R909 AND R918, 2022 CALIFORNIA ELECTRICAL CODE AND 2022 CALIFORNIA FIRE CODE. 2. CONTRACTORS SHALL BE PRESENT DURING ALL INSPECTIONS. 3. THE ROOF ACCESS POINT REQUIRING A LADDER SHALL NOT BE LOCATED OVER A WINDOW, DOOR OR LOCATED WHERE IT CONFLICTS WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS [CRC 324.7.1]. 4. A LADDER SHALL BE PROVIDED AND SECURED TO THE STRUCTURE AT THE APPROVED ROOF ACCESS POINT PER NOT "C" ABOVE WITH A CAL OSHA APPROVED DEVICE DURING ALL INSPECTIONS. 5. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATION'S INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 6. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] 7. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 8. CONTACT THE SERVICING UTILITY BEFORE POWERING ON THE PHOTOVOLTAIC SYSTEM 9. ALL WORK SHALL COMPLY WITH APPLICABLE, LOCAL, MUNICIPAL CODES, AND TO MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. THE PV SOLAR SYSTEM WILL BE INTERCONNECTED AND OPERATED IN PARALLEL WITH THE UTILITY ELECTRICAL GRID PER THE REQUIREMENTS OF THE UTILITY AND APPLICABLE CODES. THE PV SOLAR SYSTEM IS DESIGNED IN COMPLIANCE WITH CEC 690.12 (RAPID SHUTDOWN). BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA GREEN CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ENERGY CODE 1. PV SOURCE CIRCUIT(S) ARE TO BE SUNLIGHT-RESISTANT PV-WIRE AS PERMITTED BY CEC 690.31(B). 2. ALL DIRECT CURRENT CIRCUITS ARE TO BE INSTALLED IN METAL RACEWAY FROM THE POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE MAIN SERVICE PANEL AS MANDATED BY CEC 690.31(E). 3. WEATHERPROOF J-BOX – NEMA 3R. 4. ROOFTOP CONDUIT SHALL BE A MINIMUM OF 7/8" ABOVE THE ROOF SURFACE. 5. ALL WORK SHALL COMPLY WITH THE 2022 CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL OTHER LOCAL CODES AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. INSTALLER NOTES JURISDICTION STAMPS DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 2800W DC / 2030W AC Ramon Salgado 2425 Bobby Lane, Santa Ana, CA 92706 APN: 39914106 DATE: 8/28/2024 TIME: 07:52 PM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE: 26 This item has been digitally signed and sealed on Sep 23, 2024 2425 W Bobby Ln 10/21/2024 N MODULE QTY:7 MODULE MFG: LONGI MODULE MDL:LR5-54HABB-400M SITE PLAN 003 SP1 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 2800W DC / 2030W AC Ramon Salgado 2425 Bobby Lane, Santa Ana, CA 92706 APN: 39914106 DATE: 8/28/2024 TIME: 07:52 PM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE:1" = 15' NOTES: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 EXISTING PV SYSTEM (E) 13 SOLARWORLD SW 280 MODULES (E) 13 ENPHASE M250 INVERTER(S)= JURISDICTION STAMPS 2425 B O B B Y L A N E , S A N T A A N A , C A 9 2 7 0 6 DRIVEWAY PROPERTY LINE (E) AC DISCONNECT (E) MAIN SERVICE PANEL (N) IQ COMBINER (N) AC DISCONNECT (N) BATTERY (N) AC LOAD CENTER 26 This item has been digitally signed and sealed on Sep 23, 2024 2425 W Bobby Ln 10/21/2024 MSP B AC IQC AC ACL CONDUIT RUN TO BE DETERMINED IN FIELD DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 2800W DC / 2030W AC Ramon Salgado 2425 Bobby Lane, Santa Ana, CA 92706 APN: 39914106 DATE: 8/28/2024 TIME: 07:52 PM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE:1" = 10' N ARRAY 1: MODULE QTY:7 TILT:19° AZIMUTH:179° MATERIAL:Comp Asphalt Shingles 004 RP1 ROOF DETAILS FIRE CODE SETBACK BACKUP GATEWAY JB JUNCTION BOX LEGEND: MAIN SERVICE PANEL PV METER MSP PV SUB PANELSUB AC DISCONNECT AC LOAD CENTERACL EV CHARGER BATTERY EV B UM UTILITY METER (IF SEPARATED) DC DISCONNECT BG EMT CONDUIT PVC TRENCH DC AC BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 INVERTERINV (E) SOLAR MODULE ROOF PLAN JURISDICTION STAMPS MAIN BREAKER ENCLOSUREMBE SC SYSTEM CONTROLLER IQ COMBINERIQC ARRAY 1 3' 3' 26 This item has been digitally signed and sealed on Sep 23, 2024 2425 W Bobby Ln 10/21/2024 FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE 48" 2x4 RAFTER @ 24" O.C. SOLAR MODULES 7/16 X 3/4" NUT, FLANGE UNIRAC STANDARD RAIL 3/8" BOLT(E) COMPOSITION SHINGLE (E) ROOF SHEATHING TYP. PLACE SEALANT AROUND LAG BOLT AND UNDER STANDOFF BASE PREDRILLED 3/16" HOLE (1) 5/16" STAINLESS STEEL LAG BOLT W/ 2-1/2" MIN. EMBEDMENT (E) ROOF FRAMING TYP. 6" M A X UNIRAC COMP SHINGLE ATTACHMENT 2x4 RAFTER TYPICAL SOLA R M O D U L E S DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 2800W DC / 2030W AC Ramon Salgado 2425 Bobby Lane, Santa Ana, CA 92706 APN: 39914106 DATE: 8/28/2024 TIME: 07:52 PM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE: RACKING & FRAMING DETAILS 005 RF1 TYP ROOF ATTACHMENT PLANATTACHMENT DETAIL FRONT VIEW TYP FRAMING DETAIL JURISDICTION STAMPS BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 INSTALLER NOTES: 26 This item has been digitally signed and sealed on Sep 23, 2024 2425 W Bobby Ln 10/21/2024 JUNCTION BOX NEMA 3R 2 1 20A DC AC +- ~ ~ DC AC +- ~ ~ DC AC +- ~ ~ BRANCH 1: (7) LONGI LR5-54HABB-400M MODULES W/ ENPHASE IQ8PLUS-72-2-US MICROINVERTERS ENPHASE Q CABLE TO BE ATTACHED TO RAIL MIN. 3-1/2" ABOVE ROOF SURFACE (N) 125A ENPHASE IQ COMBINER 5C BOX W/ ENPHASE IQ GATEWAY X-IQ-AMI-240-5C 120/240V NEMA 3R GATEWAY 4PER MANUFACTURER'S SPECIFICATIONS, IQ GATEWAY FOR MONITORING IN IQ COMBINER CAN ACCEPT EITHER 10A OR 15A BREAKER. IQ GATEWAY MONITORING BREAKER IN IQ COMBINER SUBJECT TO EQUIPMENT AVAILABILITY BY DISTRIBUTOR 10/15A METER NUMBER: 222013494690 ROOFTOP CONDUIT SHALL BE A MINUMUM OF 7/8" ABOVE THE ROOF SURFACE (E) GROUNDING ELECTRODE (COPPER) GROUND ROD (N) 35A (E) 20A 5 (N) AC COMBINER PANEL 240/120 V 1Ø, 3W MAX MAIN BUS: 125A TO (E) SOLAR SYSTEM (N) POWER LINE FILTER Q-LCF-064-1P LOAD LINE CAPACITY: 5kWh CONT. POWER: 3.84kVA PEAK POWER: 7.68kVA === === IQBATTERY-5P-1P-NA 3 20A (N) VISIBLE/ LOCKABLE AC DISCONNECT 30A AC NON-FUSED 240V, NEMA3R EATON DG221URB,240V 30A,2P,3R3 (N) IQ BATTERY 5P MAIN (N) 175A M BI-DIRECTIONAL UTILITY METER 1PH/240V MAIN BONDING JUMPER (N) 50A TO UTILITY GRID (OVERHEAD) SOLAR BREAKER LOCATED AT THE FURTHEST END OF BUS BAR FROM THE MAIN BREAKER MAX BREAKER CALC.: 200A X 1.2 - 175A = 65A (E) 200A/175A MAIN SERVICE PANEL 240/120v 1-PH, 3-W POINT OF INTERCONNECTION LOAD SIDE 705.12(B)(3)(2) TO (E) SOLAR BREAKER EXISTING PV SYSTEM DETAILS(13) SolarWorld SW 280 MODULES (13) Enphase M250 (240) INVERTER ROOFTOP JUNCTION BOX 30A NON-FUSED AC DISCONNECT CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID CONDUCTOR (CU)CONDUIT CONDUCTORS IN CONDUIT EGC TEMP. CORR. FACTOR CONT. CURRENT MAX. CURRENT (125%)BASE AMP.DERATED AMP. TERM. TEMP. RATING 2 #10 THWN-2, in conduit 3/4" EMT 2 & (1)G #8 0.91 SEE CALCS SEE CALCS 40 36.4 90 1 #12 Q CABLE, in open air N/A N/A #10 0.91 SEE CALCS SEE CALCS 30 27.3 90 #10 THWN-2, in conduit 3/4" EMT 3 & (1)G #8 0.91 16 20 40 36.4 90 4 5 #10 THWN-2, in conduit 3/4" EMT 3 & (1)G #8 0.91 24.47 30.59 40 36.4 90 #8 THWN-2, in conduit 3/4" EMT 3 & (1)G #8 0.91 37.47 46.84 55 50.05 90 3 BRANCH CALCULATIONS BRANCH CIRCUIT DETAILS BRANCH 1 INVERTERS PER BRANCH 7 CONTINUOUS AC CURRENT 8.47 MAX AC CURRENT (125%)10.59 SYSTEM SUMMARY ARRAY PTC POWER MODULE SPECS LONGI LR5-54HABB-400M PMAX 400W PTC 376W ISC 13.72A IMP 12.93A VOC 37.05V VMP 30.94V TEMP. COEFF. OF VOC -0.265 INVERTER SPECS IQ8PLUS-72-2-US AC VOLTAGE 240V GROUND 0.97 MAX OCPD 20A RATED POWER 290W MAX OUTPUT 1.21A MAX INPUT 20A MAX INPUT 60V EFFICIENCY 0.97CEC ARRAY STC POWER 2800W 2632W MAX AC CURRENT MAX AC POWER 290W DESIGN TEMPERATURES ASHRAE 2% HIGH 30°C 2°C ASHRAE EXTREME LOW 8.47A AHJ/UTILITY NOTES: INSTALLER NOTES: ENPHASE MICROINVERTERS RSD COMPLIANT PER 690.12 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 2800W DC / 2030W AC Ramon Salgado 2425 Bobby Lane, Santa Ana, CA 92706 APN: 39914106 DATE: 8/28/2024 TIME: 07:52 PM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE: LINE DIAGRAM & DESIGN TABLES 006 LD1 BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 JURISDICTION STAMPS 26 This item has been digitally signed and sealed on Sep 23, 2024 2425 W Bobby Ln 10/21/2024 POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN CAUTION: MULTIPLE SOURCES OF POWER SERVICE BY QUALIFIED PERSONNEL ONLY N DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 2800W DC / 2030W AC Ramon Salgado 2425 Bobby Lane, Santa Ana, CA 92706 APN: 39914106 DATE: 8/28/2024 TIME: 07:52 PM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE: PLACARD & PLACARD MAP 007 PP1 LABELING PLAN BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 INSTALLER NOTES: PROPERTY MAP NOTES: FORMAT 1. WHITE LETTERING ON A RED BACKGROUND 2. MINIMUM 3/8 INCHES LETTER HEIGHT 3. ALL LETTERS SHALL BE CAPITALIZED 4. ARIAL OR SIMILAR FONT (NON-BOLD) 6"X6" DISCONNECT DIRECTORY PLAQUE INSTALL AT MAIN SERVICE PANEL MATERIAL REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS 2425 BOBBY LANE, SANTA ANA, CA 92706 NEW PV SYSTEM IS RSD COMPLIANT, EXISTING SYSTEM IS NOT RSD COMPLIANT (N) PV SYSTEM (E) PV SYSTEM JURISDICTION STAMPS ROOFTOP PV ARRAY AC COMBINER AC DISCONNECTBATTERY UTILITY METER AND MAIN SERVICE PANEL YOU ARE HERE AC DISCONNECT IQ COMBINER THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY & SOLAR)6 [690.64(B)(4)] PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES 9 [705.12(B)(3)(3)] PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT WARNING! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR [690.14(C)(2)] PLACE ON AC DISCONNECT AC DISCONNECT8AC PHOTOVOLTAIC POWER SOURCE 7 WARNING INVERTER OUTPUT CONNECTION DON'T RELOCATE THIS OVERCURRENT DEVICE PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL AND SUBPANEL IF APPLICABLE) WARNING! ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 3 [690.13(B)] PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION 1 WARNING: PHOTOVOLTAIC POWER SOURCE [690.31(D)(2)] PLACE ON JUNCTION BOXES AND CONDUIT EVERY 10' RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM4 [690.56(C)(2)] PLACE ON INVERTER AC DISCONNECT AC PHOTOVOLTAIC POWER SOURCE5MAX AC OPERATING CURRENT: AC OPERATING VOLTAGE: MAX VAC240 [690.54] PLACE LABEL AT "INTERACTIVE POINT OF INTERCONNECTION" (AT MAIN SERVICE PANEL AND SUBPANEL IF APPLICABLE) LABELING NOTES: 1.1 LABELING REQUIREMENTS BASED ON THE CALIFORNIA ELECTRICAL CODE, CALIFORNIA FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535. 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS 10 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [690.56(C)] PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE 11 LABEL LOCATED INSIDE PANEL NEXT TO PV BREAKER 8.47A D STICKER LOCATED ON MAIN ELECTRICAL PANEL DO NOT UPSIZE MAIN BREAKER BREAKER WAS DOWNSIZED TO 175A FOR PV SYSTEM WARNING SUB PANEL 5 6JUNCTION BOX METER MAIN SERVICE PANEL1 7 6 8 10 9 INVERTER INTEGRATED DC DISCONNECT 4 2 3 1 WHEN APPLICABLE AC DISCONNECT PRODUCTION METER AC DISCONNECT ROOFTOP ARRAY AC LOAD CENTER 735835835 5 11 WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE PRODUCTION METER WHEN APPLICABLE RATED FREQUENCY: PHASES: RATING (kW or kVA): AVAILABLE FAULT CURRENT (AT OUTPUT TERMINALS): MAXIMUM OUTPUT AND INPUT CURRENT (AT OUTPUT TERMINALS): MAXIMUM OUTPUT AND INPUT VOLTAGE (AT OUTPUT TERMINALS): UTILITY-INTERACTIVE CAPABLE: ENPHASE IQ BATTERY 5P 60 Hz L1 / L2 / N / PE 5kW 10kA 16A 240V YES ENERGY STORAGE SYSTEM DISCONNECT CAUTION THIS PANEL HAS SPLICED FEED- THROUGH CONDUCTORS. LOCATION OF DISCONNECT AT ENERGY STORAGE BACK UP LOAD PANEL. [312.8(A)(3)] PLACE ON MAIN PANEL IF POINT OF INTERCONNECTION IS SUPPLY SIDE CAUTION TRI POWER SOURCE. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM THIRD SOURCE IS ENERGY STORAGE SYSTEM ENERGY STORAGE SYSTEM ON SITE LOCATED WITHIN LINE OF SIGHT PLACE ON MAIN PANEL IF ESS IS IN LINE OF SIGHT ENERGY STORAGE SYSTEM ON SITE LOCATED ON ADJACENT WALL PLACE ON MAIN PANEL IF ESS IS ON ADJACENT WALL ENERGY STORAGE SYSTEM ON SITE LOCATED ON OPPOSITE WALL PLACE ON MAIN PANEL IF ESS IS ON OPPOSITE WALL ADDITIONAL PLACARDS FOR ENERGY STORAGE SYSTEM PLACE ON ACCESSIBLE ESS DISCONNECT ONLY 1 REQUIRED [705.12(D)(3)] PLACE ON MAIN PANEL IF PV SYSTEM IS ALSO CONNECTED TO PANEL 26 This item has been digitally signed and sealed on Sep 23, 2024 2425 W Bobby Ln 10/21/2024 Digitally sealed by RJM on Date: Job #: 8/13/24 Structural Analysis Report For Photovoltaic System Addition to Existing Structure At The Salgado Residence 2425 Bobby Ln Santa Ana, Ca 92706 8/13/24 Designed in Accordance with CBC 2022, ASCE 7-16 24-05471 E.O.R.: Ryan McPherson, P.E. 9240 Limonite Ave Jurupa Valley, CA 92509 Mobile: (909) 566-0066 Email: SE@mcpe.group 8/13/2024 10:54 AM 1 of 7 ©McPherson Engineering 2425 W Bobby Ln 10/21/2024 By:J.P. Date:8/13/24 Project Info 3 Gravity Loads 4 Lateral Loads 5 Wind Uplift Design 6 Summary 7 Table Of Contents *Note: This engineering report is limited to the information presented to Engineer via plans, site information, photos, and written correspondence as provided by Client. On-site structural observations and verification of site conditions are not included herein. Engineering for manufactured products such as photovoltaic modules or racking systems is excluded from this report. Please refer to the manufacturer's specifications, certifications, and pre-engineered packages for product engineering. Installations of solar modules and related equipment must be performed in accordance with manufacturer recommendations, local codes, local regulations, industry best practices, and applicable safety standards. Owner and/or Contractor shall notify Engineer should any damage, deterioration, or discrepancies between current condition of the structure or otherwise as this letter describes before proceeding with construction. This letter applies only to regions of the structure where solar modules will be supported and the supporting elements. 8/13/2024 10:54 AM 2 of 7 ©McPherson Engineering 2425 W Bobby Ln 10/21/2024 By:J.P. Date:8/13/24 Location: 2425 Bobby Ln Santa Ana, Ca 92706 Existing Structure Info: Number of Stories =1 Aroof =2498 sq. ft.Roof Square Footage A3rd_flr =0 sq. ft.Third Floor Square Footage (if applicable) A2nd_flr =0 sq. ft.Second Floor Square Footage (if applicable) Site Properties: Latitude = Longitude = Ss = 1.342 S1 = 0.477 Exposure Category =C Ult. Wind Speed =100 m.p.h. P.V. Array Info: Model =LR5-54HABB-400M Height of Panel =67.79 in. Width of Panel =44.64 in. Area of Panel =21.0 ft.2 Number of New Panels =7 Number of Exis. Panels =14 Total Area of Array =441.3 ft.2 Spacing of Anchors =4.0 ft. max. on center rows of racks per panel =2 Panel Tilt =7-27 deg Project Info 33.770239 -117.902724 8/13/2024 10:54 AM 3 of 7 ©McPherson Engineering 2425 W Bobby Ln 10/21/2024 By:J.P. Date:8/13/24 Existing Loads: Roof Design Loads: Roofing = 4.0 p.s.f.Composition roofing Sheathing =1.5 p.s.f.1/2" Plywood Framing =1.5 p.s.f.2x4 Rafters Misc =1.0 p.s.f. DLr1 =8.0 p.s.f.Roofing Dead Load (applied to top of rafters/trusses only) Ceiling =2.0 p.s.f.Drywall and framing DLr2 =10.0 p.s.f.Total Existing Roof Dead Load LLr = 20.0 p.s.f.Roof Live Load (Per C.B.C, Table 1607.1) SL = 0.0 p.s.f.Snow Load Floor Design Loads: (if applicable) Flooring =10.0 p.s.f.Weight of floor finish Sheathing = 2.2 p.s.f.3/4" plywood Framing =2.0 p.s.f.2x framing or manufactured floor truss Interior Partitions =15.0 p.s.f.2x framed walls with drywall finish each side Ceiling =5.0 p.s.f.Drywall ceiling finish below Misc. = 0.8 p.s.f. DLf = 35.0 p.s.f.Total Existing Floor Dead Load Proposed Loads: Panels =2.9 p.s.f.weight of panels including rack system DLr1_proposed =10.9 p.s.f.Proposed Roof Dead Load (applied to top only) DLr2_proposed =12.9 p.s.f.Total Proposed Roof Dead Load LLr_proposed = 0.0 p.s.f. Check Proposed Gravity Loads: Total Existing Roof Load Wex = (DLr1 + LLr) (Aroof) =69.9 kips Total Proposed Roof Load Wprop = (DLr1 + LLr) (Aroof - Aarray) + (DLr1_proposed + LLr_proposed) (Aarray) =62.4 kips Proposed Load Demand Gravity Loads Roof Live Loads need not be applied to the area covered with by PV panel where the clear space between the panels and the roof sureface is 24in or less, 1607.13.5.1 item 1 Exception Wprop - W ex =-10.81%TOTAL DECREASE IN GRAVITY LOADS, PANELS OK!Wex 8/13/2024 10:54 AM 4 of 7 ©McPherson Engineering 2425 W Bobby Ln 10/21/2024 By:J.P. Date:8/13/24 Seismic Design Parameters Risk Category =2 Per Table 1-5-1 R =6.5 Response Modification Factor (Table 12-2.1) Site Class =D Per 11.4.2 Ie =1 Seismic Importance Factor (Table 1.5-2) Ss =1.34 Short Period P.G.A. S1 =0.48 1-Sec Period P.G.A. S.D.C. =D Seismic Design Category Per 11.6 Fa =1.20 Site Coefficient per Table 11.4-1 ASCE 7-16 Supplement #1 Tables used for Fa and Fv Fv =1.70 Site Coefficient per Table 11.4-2 (note: section 11.4.8 Exception #2 calc used) SMS = SDS Fa =1.61 Short Period M.C.E. Per Eq. 11.4-1 SM1 = SD1 Fv =0.81 1-Sec Period M.C.E. Per Eq. 11.4-2 SDS = 2/3 (SMS) =1.07 Short Period Design Parameter Per Eq 11.4-3 SD1 = 2/3 (SM1) =0.54 1-Sec Period Design Parameter Per Eq 11.4-4 Approximate Fundamental Period (Per 12.8.2.1) per Eq. 12.8-7 hn = 15 ft Ct =0.02 (per table 12.8-2) x = 0.75 (per table 12.8-2) T =0.15 sec Approximate Fundamental Period TL =8 sec Long-Period Transition Period per Figure 22-12 Seismic Response Coefficient (Per 12.8.1.1) CS = (SDS Ie)/R = 0.17 Seismic Response Coefficient Per Eq. 12.8-2 Cs1 = 1.5*(SD1 Ie)/R T = 0.82 Max. Seismic Response Coefficient Per Eq. 12.8-3 if T ≤ TL Cs2 =0.01 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs2 = 0.044 SDS Ie =0.05 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs3 = 0.5 S1 Ie/R =0.04 Min. Seismic Response Coefficient Per Eq. 12.8-6 if S1 ≥ 0.6g CS =0.17 Design Seismic Coefficient Check Additional Base Shear Wexisting =25.0 kips Weight of Existing Structure Wpanels =1.3 kips Weight of Proposed Panels Vexisting = Cs W existing =4.1 kips Roof Level Shear of Existing Structure Vpanels = Cs W panels =0.2 kips Additional Roof Level Shear of Proposed Panels Vpanels Vexisting Lateral Loads T = Ct (hn)x = 5.05%< 10%PER C.E.B.C. 502.5 EXCEPTION, STRUCTURE DOES NOT REQUIRE SEISMIC RETROFIT, PANELS OK! 8/13/2024 10:54 AM 5 of 7 ©McPherson Engineering 2425 W Bobby Ln 10/21/2024 By:J.P. Date:8/13/24 Rooftop Solar Panels Wind Pressures (Section 29.4, ASCE 7-16) Vult =100 mph Kzt =1.00 (sec 26.8.2)h =15 ft Exposure Category =C Kz = 0.85 (sec 26.10.1) Roof Zone =2 Kd =0.85 (sec 26.6) Roof θ =7-27 deg Ke =1.00 (sec 26.9) qh = 0.00256 Kz Kzt Kd Ke V2 qh =18.50 (eq. 26.10-1) GPp =-2 uplift γE =1.5 (sec 29.4.4) γa =0.78 (fig 29.4-8) γE =1.5 FIG 29.4-7)γc =0.94 (fig 29.4-7)hpt =0 γa =0.78 (fig 29.4-8)γp =0.9 (fig 29.4-7)ω =0.00 deg (panel tilt) GPp =-2 uplift GCrm =1.4 uplift p = qh (GPp) γE γa (eq 29.4-7)p = qh (GCrn) γE γC γp (eq 29.4-6) p =-43.2 p.s.f.p =32.8 p.s.f. Check Anchorage to Existing Structure 0.6DL - 0.6W controlling load combination (eq. 16-15 for ASD) DL =2.9 p.s.f.dead load of panel (including rack system) W = 43.2 p.s.f.wind load normal to face of panel Arealag =11.3 sq. ft.area tributary to each anchor SPanc =4.0 ft.spacing of anchors Puplift = Arealag (0.6DL - 0.6W) =273.6 lbs.total uplift on anchor Material =SP lumber anchor material Dialag =5/16 in.diameter of screw Penlag =2.5 in.min. penetration to existing framing W lag =307 lb.withdrawal load per ICC ESR3223 CD =1.6 load duration factor for wind per NDS Table 2.3.2 Ct =0.8 temperature factor per NDS Table 2.3.3 Noscrews =1 number of screws in withdrawal Pallow = Wlag * Noscrews =982.4 lbs.total allowable withdrawal on anchor Puplift Pallow Anchorage =USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Wind Uplift Anchorage Flush Mounted Panels - ASCE Section 29.4.4 (where applicable) Flat Roof Panels - ASCE Section 29.4.3 (where applicable) =0.28 < 1.00 Anchor is OK! 8/13/2024 10:54 AM 6 of 7 ©McPherson Engineering 2425 W Bobby Ln 10/21/2024 By:J.P. Date:8/13/24 Gravity Loads: DEMAND DECREASED BY 10.81% = OK! Lateral Loads: DEMAND INCREASED BY 5.05% < 10% = OK! Anchorage: DEMAND OF 273.6LB. < CAPACITY OF 982.4LB. = OK! USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Summary: STRUCTURE IS ADEQUATE FOR THE PROPOSED PV ARRAY ANCHORS ON EAVES/OVERHANGS ARE OK! Summary 8/13/2024 10:54 AM 7 of 7 ©McPherson Engineering 2425 W Bobby Ln 10/21/2024 2425 W Bobby Ln 10/21/2024 2425 W Bobby Ln 10/21/2024 Rev: 8/29/19 SOL-01 CBC 2016 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PHOTOVOLTAIC BETTER EARTH ELECTRIC 1024460 C-10 x x x x x x x x x x Mark Hellsund 661-470-2108 cerritospermits@betterearth.solar 8/22/2024 2425 Bobby Lane, Santa Ana, CA 92706 2425 W Bobby Ln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pNN 8JEUIpNN .PEVMF5ZQF 5FTUJOH$POEJUJPO .BYJNVN1PXFS 1NBY8 0QFO$JSDVJU7PMUBHF 7PD7 4IPSU$JSDVJU$VSSFOU *TD" 7PMUBHFBU.BYJNVN1PXFS 7NQ7 $VSSFOUBU.BYJNVN1PXFS *NQ" .PEVMF&DJFODZ &MFDUSJDBM$IBSBDUFSJTUJDT45$".8N˫/0$5".8N˫NT5FTUVODFSUBJOUZGPS1NBYp 45$ /0$5 -3)"##. 45$ /0$5 -3)"##. 45$ /0$5 -3)"##. 45$ /0$5 -3)"##. .FDIBOJDBM-PBEJOH 'SPOU4JEF.BYJNVN4UBUJD-PBEJOH1B 3FBS4JEF.BYJNVN4UBUJD-PBEJOH1B )BJMTUPOF5FTUNN)BJMTUPOFBUUIFTQFFEPGNT 5FNQFSBUVSF3BUJOHT 45$ 5FNQFSBUVSF$PFDJFOUPG*TD˫ 5FNQFSBUVSF$PFDJFOUPG7PD˫ 5FNQFSBUVSF$PFDJFOUPG1NBY˫ 0QFSBUJOH1BSBNFUFST 0QFSBUJPOBM5FNQFSBUVSF˫_˫ 1PXFS0VUQVU5PMFSBODF_ .BYJNVN4ZTUFN7PMUBHF%$7 *&$6- .BYJNVN4FSJFT'VTF3BUJOH" /PNJOBM0QFSBUJOH$FMM5FNQFSBUVSFp˫ 1SPUFDUJPO$MBTT$MBTT** #JGBDJBMJUZp 6-UZQF *&$$MBTT$ 'JSF3BUJOH &MFDUSJDBMDIBSBDUFSJTUJDTXJUIEJFSFOUSFBSTJEFQPXFSHBJO SFGFSFODFUP8GSPOU 1NBY8 7PD7 *TD" 7NQ7 *NQ" 1NBYHBJO 45$ /0$5 -3)"##. 4QFDJDBUJPOTJODMVEFEJOUIJTEBUBTIFFUBSF TVCKFDUUPDIBOHFXJUIPVUOPUJDF-0/(J SFTFSWFTUIFSJHIUPGOBMJOUFSQSFUBUJPO 7%( 45$ /0$5 -3)"##. .FDIBOJDBM1BSBNFUFST $FMM0SJFOUBUJPO +VODUJPO#PY*1 (MBTT%VBMHMBTT NN4FNJUFNQFSFEHMBTT 'SBNF"OPEJ[FEBMVNJOVNBMMPZGSBNF 8FJHIULH %JNFOTJPONN &70$POOFDUPS5ZQF 1BDLBHJOH NN pNN MFOHUIDBOCFDVTUPNJ[FE QDTQFSQBMMFUQDTQFS(1 QDT QDT POMZGPS64" QFS)$ 0VUQVU$BCMF :FBS1PXFS8BSSBOUZ 2425 W Bobby Ln 10/21/2024 IQ8SP-12A-DSH-00207-3.0-EN-US-2024-02-12 DATA SHEET IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software-defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC), which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built using advanced 55-nm technology with high-speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Easy to install • Lightweight and compact with plug-and-play connectors • Power line communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Compliant with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB) NOTE: • IQ8 Microinverters cannot be mixed with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, and so on) in the same system. • IQ Microinverters ship with default settings that meet North America’s IEEE 1547 interconnection standard requirements. Region-specific adjustments may be requested by an Authority Having Jurisdiction (AHJ) or utility representative according to the IEEE 1547 interconnection standard. An IQ Gateway is required to make these changes during installation. © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. *Meets UL 1741 only when installed with IQ System Controller 2 or 3. **IQ8 and IQ8+ support split-phase, 240 V installations only. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-and-play MC4 connectors. IQ8 Series Microinverters are UL Listed as PV rapid shutdown equipment and conform with various regulations, when installed according to the manufacturer’s instructions. IQ8SP-12A-DSH-00207-3.0-EN-US-2024-02-12 (1) No enforced DC/AC ratio. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. INPUT DATA (DC)UNITS IQ8-60-2-US IQ8 PLUS -72-2-US Commonly used module pairings1 W 235–350 235–440 Module compatibility —To meet compatibility, PV modules must be within maximum input DC voltage and maximum module Isc listed below. Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator. MPPT voltage range V 27–37 27–45 Operating range V 16–48 16–58 Minimum/Maximum start voltage V 22/48 22/58 Maximum input DC voltage V 50 60 Maximum continuous input DC current A 10 12 Maximum input DC short-circuit current A 25 Maximum module (Isc) A 20 Overvoltage class DC port —II DC port backfeed current mA 0 PV array configuration —Ungrounded array; no additional DC side protection required; AC side protection requires maximum 20 A per branch circuit. OUTPUT DATA (AC)UNITS IQ8-60-2-US IQ8 PLUS -72-2-US Peak output power VA 245 300 Maximum continuous output power VA 240 290 Nominal grid voltage (L-L)V 240, split-phase (L-L), 180° Minimum and Maximum grid voltage2 V 211-264 Maximum continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 47–68 AC short-circuit fault current over three cycles Arms 2 Maximum units per 20 A (L-L) branch circuit3 —16 13 Total harmonic distortion %<5 Overvoltage class AC port —III AC port backfeed current mA 30 Power factor setting —1.0 Grid-tied power factor (adjustable)—0.85 leading … 0.85 lagging Peak efficiency %97.7 CEC weighted efficiency %97 Nighttime power consumption mW 23 25 MECHANICAL DATA Ambient temperature range -40°C to 60°C (-40°F to 140°F) Relative humidity range 4% to 100% (condensing) DC connector type MC4 Dimensions (H × W × D)212 mm (8.3 in) × 175 mm (6.9 in) × 30.2 mm (1.2 in) Weight 1.08 kg (2.38 lbs) Cooling Natural convection–no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion-resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/Outdoor IQ8 and IQ8+ Microinverters 2425 W Bobby Ln 10/21/2024 IQ8SP-12A-DSH-00207-3.0-EN-US-2024-02-12 COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01. This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014, NEC 2017, NEC 2020, and NEC 2023 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV Systems, for AC and DC conductors, when installed according to the manufacturer’s instructions. REVISION DATE DESCRIPTION DSH-00207-3.0 February 2024 Updated the information about IEEE 1547 interconnection standard requirements. DSH-00207-2.0 October 2023 Included NEC 2023 specification in the “Compliance” section. DSH-00207-1.0 September 2023 Updated module compatibility specification. 2425 W Bobby Ln 10/21/2024 DATA SHEET IQ Battery 5P The IQ Battery 5P all-in-one AC-coupled system is powerful, reliable, simple, and safe. It has a total usable energy capacity of 5.0 kWh and includes six embedded grid-forming microinverters with a 3.84 kVA continuous power rating. It provides backup capability, and installers can quickly design the right system size to meet the customer needs. Powerful • Provides 3.84 kVA continuous and 7.68 kVA peak power • Doubles the available power per kWh of prior generations of IQ Battery • Includes six embedded microinverters Reliable • 15-year limited warranty • Cools passively with no moving parts or fans • Uses wired communication for fast and consistent connection • Updates software and firmware remotely Simple • Fully integrated AC battery system • Installs and commissions easily • Supports Backup, Self-Consumption, and time-of-use (TOU) modes • Offers homeowners remote monitoring and control from the Enphase App • Field replaceable components Safe • Evaluated to UL 9540A for thermal runaway fire propogation and reduced separation distance as required in 2021 IRC R328.3.1, 2021 IFC 1207.1.5, and 2023 NFPA 855 15.3.1 and 9.1.5.1 • Uses lithium iron phosphate (LFP) chemistry for maximum safety and longevity IQ BATTERY 5P SPECIFICATIONS Rated (continuous) output power 3.84 kVA Rated output current (@240 VAC) 16 A Interconnection Single-phase Nominal voltage 240 VAC Nominal frequency 60 Hz Usable capacity 5.0 kWh Ambient operating temperature range (charging) -20°C to 50°C (-4°F to 122°F) non-condensing Ambient operating temperature range (discharging) -20°C to 55°C (-4°F to 131°F) non-condensing Chemistry Lithium iron phosphate (LFP) Mounting Wall-mount or pedestal-mount (sold separately) Floor-mounted with pedestalWall-mounted Dimensions in inches 22 . 8 " 7.4" 9.9"1.2" 3. 3 " 1 Follow all installation instructions and local codes and requirements of the Authority Having Jurisdiction (AHJ) when installing the Enphase Energy System. MODEL NUMBER IQBATTERY-5P-1P-NA The IQ Battery 5P system with integrated IQ Microinverters (SKU: IQ8D-BAT) and battery management system (BMS) with battery controller LIMITED WARRANTY IQ Battery 5P unit >60% capacity, up to 15-year or 6,000 cycles2 OUTPUT (AC)@240 VAC3 Rated (continuous) output power 3.84 kVA Peak output power 7.68 kVA (three seconds), 6.14 kVA (ten seconds) Nominal voltage/range 240/211–264 VAC Nominal frequency/range 60/57–63 Hz Rated output current (@240 VAC)16 A Peak output current (@240 VAC)32 A (three seconds), 25.6 A (ten seconds) Power Start capability Up to 48 A LRA4 Power factor (adjustable)0.85 leading ... 0.85 lagging Maximum units per 20 A branch circuit One unit (single-phase) Maximum conductor size supported 3 AWG Overcurrent protection device (OCPD) for 3 AWG cable 80 A Interconnection Single-phase AC round-trip efficiency5 90% BATTERY Total capacity 5.0 kWh Usable capacity 5.0 kWh DC round-trip efficiency 96% Nominal DC voltage 76.8 V Maximum DC voltage 86.4 V Ambient operating temperature range (charging) -20°C to 50°C (-4°F to 122°F) non-condensing Ambient operating temperature range (discharging) -20°C to 55°C (-4°F to 131°F) non-condensing Optimum operating temperature range 0°C to 30°C (32°F to 86°F) Chemistry Lithium iron phosphate (LFP) MECHANICAL DATA Dimensions (H x W x D) 980 mm × 550 mm × 188 mm (38.6 in × 21.7 in × 7.4 in) Lifting weight 66.3 kg (146.1 lb) Total installed weight 78.9 kg (174 lb) Enclosure Outdoor-NEMA 3R IQ8D-BAT Microinverter enclosure NEMA type 6 Cooling Natural convection Altitude Up to 2,500 meters (8,202 feet) Mounting Wall-mount or pedestal-mount (sold separately) 2 Whichever occurs first. Restrictions apply. 3 Supported in both grid-connected and backup/off-grid operations. 4 Power Start capability may vary. 5 AC to the battery to AC at 50% power rating. 2425 W Bobby Ln 10/21/2024 FEATURES AND COMPLIANCE Compatibility Compatible with IQ and M Series Microinverters, IQ System Controller 3/3G, IQ Combiner 5/5C, and IQ Gateway for grid-tied and backup operation Communication Wired control communication Services Backup, Self-Consumption, TOU, and NEM integrity Monitoring Enphase Installer Platform and Enphase App monitoring options; API integration Compliance CA Rule 21 (UL 1741-SA), IEEE 1547:2018 (UL 1741-SB, 3rd Ed.) CAN/CSA C22.2 No. 107.1-16 UL 95406, UL 9540A, UN 38.3, UL 1998, UL 991, NEMA Type 3R, AC156 EMI: 47 CFR, Part 15, Class B, ICES 003 Cell module: UL 1973, UN 38.3 Inverters: UL 62109-1, IEC 62109-2 WHAT’S IN THE BOX IQ Battery 5P unit IQ Battery 5P unit (B05-T02-US00-1-3) ID cover and conduit cover IQ Battery 5P cover with two conduit covers for the left and right sides of the unit Bottom mounting bracket and top shield Bottom mounting bracket for mounting the battery on the wall. One top shield is required for UL 9540A M5 seismic screws Two M5 seismic screws for securing the battery unit on the bottom mounting bracket M4 grounding screws Two M4 grounding screws for securing the top shield on the bottom mounting bracket M5 ID cover grounding screws Two M5 ID cover grounding screws for the EMI/EMC requirement Cable ties Six cable ties for securing field cables to the unit Control (CTRL) connector Spare CTRL connector without resistor for CTRL wiring Control (CTRL) connector with resistor Spare CTRL connector with resistor for CTRL wiring Quick install guide (QIG)QIG for IQ Battery unit installation instructions OPTIONAL ACCESSORIES AND REPLACEMENT PARTS IQ8D-BAT-RMA IQ8D-BAT Microinverter for field replacement B05-T02-US00-1-3-RMA IQ Battery 5P Battery unit for field replacement B05-CX-0550-O IQ Battery 5P cover for field replacement B05-PI-0550-O IQ Battery 5P pedestal mount B05-CP-096-O IQ Battery 5P conduit plates for field replacement. Includes one left-side and one right-side conduit plate B05-WB-0543-O IQ Battery 5P wall bracket for field replacement. Includes one bottom mounting bracket and one top shield IQBATTERY-HNDL-5 IQ Battery 5P lifting handles. Includes one left-side and one right-side lifting handle B05-ACFB-080-O IQ Battery 5P AC filter board for field replacement B05-BMSNA-0490-O IQ Battery 5P BMS board for field replacement B05-CANB-063-O IQ Battery 5P control communication board for field replacement B05-NICS-0524-O, B05-NUCS-0524-O IQ Battery 5P control switch is preinstalled on the wiring cover for field replacement 6 Following local standards, choose a well-ventilated, non-habitable indoor location (like a 2-car garage) or an outdoor location where the ambient temperature and humidity are within -4°F to 131°F (-20°C to 55°C) and 5% to 95% RH, non-condensing. Avoid direct sunlight to ensure the temperature stays in the optimal operating range. This ensures charging and discharging currents are not de-rated due to temperature. The full performance will occur within 59°F to 113°F (15°C to 45°C) while charging and within 41°F to 122°F (5°C to 50°C) while discharging. Components of the Enphase Energy System IQ Gateway The IQ Gateway with Current Transformers provides complete control and insight into the Enphase Energy System. Communications Kit 2 INT The Communications Kit 2 INT enables wired communication between the battery and gateway for grid-tied operation. IQ Battery 5P accessories The IQ Battery 5P lifting handles are reusable and ease the installation process. The IQ Battery 5P pedestal enables floor mounting of the IQ Battery 5P. IQ Microinverters IQ Series Microinverters pack more power into less space than other rooftop solar systems and make rooftop solar more productive, reliable, smart, and safe. 2425 W Bobby Ln 10/21/2024 Revision history © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. IQB-5P-DSH-00010-6.0-EN-US-2024-05-28 REVISION DATE DESCRIPTION DSH-00010-6.0 May 2024 • Updated safety section on page 1. • Updated the document to a new template. DSH-00010-5.0 February 2024 Updated the SKU on page 1. DSH-00010-4.0 November 2023 Updated the “Output (AC)” table. DSH-00010-3.0 September 2023 • Updated product images. • Editorial updates. DSH-00010-2.0 July 2023 • Added battery isometric view on the first page. • Editorial updates. DSH-00010-1.0 May 2023 Initial release. 2425 W Bobby Ln 10/21/2024 FOR QUESTIONS OR CUSTOMER SERVICE CONTACT: 505-242-6411 | SALES@UNIRAC.COM | WWW.UNIRAC.COM PUB2024JAN01-V1 UL2703AUL2703CONFORMS TOCONFORMS TO •High strength, waterproof attachment. •No more lifting, prying or damaging shingles. •With an outer shield contour- conforming gasket, and pressurized sealant chamber the Triple Seal Technology delivers a 100% waterproof connection. •Simply drive the lag bolt and inject sealant into the port to create a permanent pressure seal. •Faster Installation in just 3 steps; pre-install, secure, and seal. PROTECT THE ROOF LOCK OUT WATER HIGH-SPEED INSTALLATION FLASHLOC™ COMP KIT Available in Dark and Mill WHY FLASHLOC™ COMP? FLASHLOC™ is the ultimate attachment for composition shingle and rolled comp roofs. The all-in-one mount installs fast — no kneeling on hot roofs to install flashing, no prying or cutting shingles, no pulling nails. Simply drive the lag bolt and inject sealant into the base. FLASHLOC’s patented TRIPLE SEAL Technology preserves the roof and protects the penetration with a permanent pressure seal. Don’t just divert water, LOC it out! KITTED WITH •TEN (10) Flashloc Attachments •TEN (10) Lag bolts with sealing washer Inject sealantinto the port to create permanent preassureseal Countour-conforminggasket Triple Seal Technology100% waterproof connection Pressurizedsealant chamber •T-Bolt rail attachment hardware •ONE (1) tube of approved Sealant R BETTER SOLAR STARTS HERE 2425 W Bobby Ln 10/21/2024 UL2703CONFORMS TOFOR QUESTIONS OR CUSTOMER SERVICE CONTACT: 505-242-6411 | SALES@UNIRAC.COM | WWW.UNIRAC.COM PUB2024JAN01-V1 •Designed for Unirac’s Solarmount rail systems and certified to UL2703A for low- slope AND steep-slope roofs •One-step butyl application for easy install and reliable waterproofing FEATURING SOLARMOUNT •Universal AF mid clamps and end clamps adjust to module heights from30-46mm in a great looking, easy to install fastener •Pro-series clamps feature hiddenfasteners for fantastic aesthetics •Standard clamps feature tight rowspacing and various clamps toaccommodate module frames up to51mm in height •Solarmount Standard and Solarmount Lightrails profiles for installations across thecountry, including Puerto Rico •Huge selection of attachments for any roofform comp shingle to tile •Adjustable tilt legs certified to UL2703 todial in your system just right DIFFERENT CLAMPS FOR DIFFERENT NEEDS OPTIONS FOR ANY APPLICATION SOLARMOUNT WHY SOLARMOUNT? SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with universal clamps, tons of attachment options, full system UL 2703 certification, and 25-year warranty. Sleek rails for both light and heavy duty applications, with optional trim, make for a reliable, cost-effective, great looking racking solution. OPTIONALFRONT TRIM Two rail profiles for light and heavy duty applications Components available in Mill and Dark finishes for any aesthetic and any budget SM PRO SERIESMID CLAMPUNIVERSAL MID CLAMP CONCEALED SM END CLAMPUNIVERSAL END CLAMP SOLARMOUNT BUTYL SOLARMOUNT PROFILEAND LIGHT PROFILE R BETTER SOLAR STARTS HERE 2425 W Bobby Ln 10/21/2024