GENERAL NOTES:
1.THE FOLLOWING CODES WERE USED IN DESIGN:
2022 CALIFORNIA BUILDING STANDARDS CODE (TITLE 24, PART 2), IBC 2021 AND ASCE-7 (2016).
2.STRUCTURAL LOADINGS:
WIND:
WIND (3 SECOND GUST)...........................................VULT = 100MPH
VASD = 78 MPH
EXPOSURE...........................................................................C
RISK CATEGORY.................................................................II
WIND BASE SHEAR.......................................................Vb = 370 LBS (PRE-BROWSE BOARD)
SEISMIC:
SEISMIC IMPORTANCE FACTOR (Ie).................................1.0
MAPPED SPECTRAL RESPONSE ACCELERATIONS..Ss.......1.293g
S1........0.461g
DESIGN SPECTRAL RESPONSE ACCELERATIONS SDS......1.034g
SD1......0.565g
SITE CLASS...........................................................................D
SEISMIC DESIGN CATEGORY.............................................D
SEISMIC RESPONSE COEFFICIENT (CS)..............................0.296
COMPONENT RESPONSE MODIFICATION FACTOR (RP)..3.5
SEISMIC DESIGN FORCE (FP)..............................................0.11 KIPS (PRE-BROWSE BOARD)
FROST DEPTH...............................................................................0'-6"
3.ALL FOOTING EXCAVATIONS ARE TO BE CLEAR OF WATER AND FOREIGN MATTER BEFORE PLACING CONCRETE.
4.PRESUMPTIVE MINIMUM ALLOWABLE LATERAL SOIL BEARING PRESSURE (So) OF 100 PSF. CONTRACTOR SHALL
CONFIRM AN ALLOWABLE BEARING PRESSURE (Sb) OF 1500 PSF. ALLOWABLE BEARING PRESSURE SHALL BE
VERIFIED BY CONTRACTOR PRIOR TO CONCRETE PLACEMENT.
5.FOUNDATION SHALL NOT BE PLACED ON OR AT THE TOP OF A SLOPE EXCEEDING 3:1 WITHOUT EVALUATION BY A
PROFESSIONAL LICENSED IN THAT STATE. DO NOT PLACE FOUNDATION IN FILL MATERIAL.
6.DEPTH OF PIER FOUNDATIONS MAY BE LOWERED IF NEEDED TO OBTAIN LOCAL FROST DEPTH ELEVATIONS OR IF
REQUIRED DUE TO POOR SOIL CONDITIONS. VERIFY FROST DEPTH ELEVATIONS WITH LOCAL CODE OFFICIAL.
7.ELECTRICAL CONTRACTOR TO PROVIDE INFORMATION ON CONDUIT AND ELECTRICAL REQUIREMENTS AND
CONTRACTOR (INSTALLER) SHALL COORDINATE PLACEMENT TO MAINTAIN 2" CLEAR TO ANCHOR BOLTS.
8.COORDINATE LOCATIONS OF SIGNS AND FOUNDATIONS WITH SITE PLAN.
9.CONTRACTOR SHALL CUT EXCESS SONOTUBE FROM AROUND THE PERIMETER OF THE PIER FOUNDATION AFTER
PLACEMENT OF BOARD (PRIOR TO LEAVING SITE).
10.CONTRACTOR SHALL NOT DEVIATE FROM STRUCTURAL DRAWING WITHOUT PRIOR WRITTEN CONSENT AND
INSTRUCTIONS REGARDING ANY CHANGE TO THE CONTRACT DRAWINGS. ANY DEVIATION FROM THIS DESIGN
OR FROM ANY PART OF THIS DRAWING WITHOUT PRIOR WRITTEN CONSENT OF THIS ENGINEER SHALL VOID ALL
LIABILITY ASSOCIATED WITH THIS WORK.
11.SPECIAL INSPECTIONS ARE NOT REQUIRED FOR THESE SIGN FOUNDATIONS.
CONCRETE NOTES:
1.ALL FOOTINGS SHALL BEAR ON FIRM UNDISTURBED RESIDUAL SOIL AND/OR EARTH FILL COMPACTED TO 95% OF
ITS MAXIMUM DRY DENSITY AS PER ASTM D698 (STANDARD PROCTOR) UNLESS NOTED OTHERWISE.
CONTRACTOR SHALL CONFIRM SOIL CAPACITY PRIOR TO CONCRETE PLACEMENT.
2.ALL PIERS TO EXTEND TO FROST DEPTH AS DETERMINED BY LOCAL JURISDICTION. VERIFY WITH LOCAL BUILDING
OFFICIAL.
3.TOP OF PIERS SHALL BE SLOPED SUCH THAT MOISTURE CANNOT ACCUMULATE.
4.ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI 301 "STRUCTURAL CONCRETE FOR
BUILDINGS" AND ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE."
5.ALL CAST-IN-PLACE CONCRETE SHALL ATTAIN AN ULTIMATE COMPRESSIVE STRENGTH (fc) OF 3000 PSI AT AN
AGE OF 28 DAYS UNLESS OTHERWISE NOTED.
6.ALL REINFORCING STEEL SHALL BE ASTM A 615, GRADE 60 DEFORMED BARS, UNLESS OTHERWISE NOTED.
7.CONCRETE PROTECTION FOR REINFORCING AS WELL AS PLACING AND FABRICATION OF REINFORCING SHALL
BE IN ACCORDANCE WITH THE "THE AMERICAN CONCRETE INSTITUTE BUILDING CODE REQUIREMENTS" (ACI
318).
8.ALL CAST-IN-PLACE CONCRETE SHALL BE AIR-ENTRAINED TO 6% (±112%). WATER/CEMENT RATIO SHALL NOT
EXCEED 0.48.
9.THE MINIMUM CONCRETE COVER FOR THE PROTECTION OF REINFORCEMENT SHALL BE AS NOTED.
10.BEFORE PLACING CONCRETE, ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED,
AND MAINTAINED SECURELY IN PLACE. NO "WET SETTING" IS ALLOWED.
11.AGGREGATES IN NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C-33 (HARDROCK).
12.PORTLAND CEMENT SHALL BE TYPE II FOR ALL CONCRETE CONFORMING TO ASTM C150, LOW ALKALI.
13.FLY ASH OR OTHER POZZOLANS CONFORMING TO ASTM C618 CLASS N OR F MAY BE USED AS A PARTIAL
SUBSTITUTION FOR PORTLAND CEMENT UP TO A MAXIMUM OF 25% TOTAL CEMENTITIOUS MATERIALS BE WEIGHT
IF THE MIX DESIGN IS PROPORTIONED PER ACI318, SECTION 5.3. CONTRACTOR SHALL FORWARD DESIGN MIX
TO ARCHITECT AND STRUCTURAL ENGINEER OF RECORD.
14.CONCRETE MIXING OPERATIONS, ETC. SHALL CONFORM TO ASTM C94.
15.DO NOT USE ANY CONCRETE OR GROUT CONTAINING
CHLORIDES. WATER USED IN MIX SHALL BE CLEAN AND POTABLE.
HEAVY HEX
LEVELING NUT
(GALV.)
(2) HEAVY 3 4" HEX
TOP NUT (GALV.)
ADHESIVE ANCHOR
BOLT DETAIL
NOT TO SCALE
2"X2"X14" HEAVY
STEEL PLATE
WASHERS OR
212"Ø x 14" THK.
WASHER (GALV.)
3 4"Ø ALL-THREAD
RODS (GALV.)
1'
-
5
"
TYPICAL ANCHOR BOLT PATTERN
NOT TO SCALE
NOTE:IF BOLTS ARE CUT, CONTRACTOR SHALL PROVIDE
GALVANIZING SPRAY AT CUT BOLTS TO AVOID RUSTING.
TYPICAL SIGN BASE PLATE DETAIL
NOT TO SCALE
TYPICAL CONNECTION DETAIL
NOT TO SCALE
STEEL NOTES:
1.REINFORCEMENT: GRADE 60.
2.ANCHOR RODS, NUTS, AND WASHERS SHALL BE SHIPPED AS AN
ASSEMBLY FROM THE SIGN/LIGHTING MANUFACTURER. COORDINATE
WITH MANUFACTURER.
A. THREADED RODS: ASTM F1554, GRADE 36
B. PLATE WASHERS: ASTM A-36
C. WASHERS: ASTM F-436
D. NUTS: A563DH OR A194-2H
3.ALL HARDWARE SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM
A-123, HOT-DIP GALVANIZED, ZINC PLATED OR MECHANICALLY
GALVANIZED.
4.ANCHOR BOLTS TO BE SET IN ACCORDANCE WITH AISC CODE OF
STANDARD PRACTICE.
5.FIELD HEATING TO BEND STEEL SHALL NOT BE ALLOWED.
6.ANCHOR BOLTS TO BE CUT, IF NEEDED, TO 5". APPLY COLD
GALVANIZING TO CUT BOLT ENDS.
7.CONTRACTOR (INSTALLER) IS RESPONSIBLE FOR THE MEANS AND
METHODS OF CONSTRUCTION IN REGARDS TO JOBSITE SAFETY.
8.STRUCTURAL SIGN FRAME AND BASE PLATE DETAILS ARE PROVIDED BY
SIGN MANUFACTURER. COORDINATE ALL ATTACHMENTS OF SIGN
WITH MANUFACTURER. REFER TO SIGN MANUFACTURER DRAWINGS
AND INSTRUCTIONS FOR ADDITIONAL INFORMATION.
9.DO NOT CUT ANCHOR BOLTS OR RODS AFTER INSTALLATION OF
FRAME.
114"
M
A
X
.
TIGHTEN TOP NUTS 16 TURN
BEYOND HAND-TIGHT
(TURN OF NUT METHOD)
(MIN 60°, MAX 80°)
NOTE:THE DISTANCE FROM THE TOP OF THE
FOUNDATION TO THE BOTTOM OF THE BASE
PLATE SHALL BE NO GREATER THAN 114".
60°
FLAT WASHERS
5"
P
R
O
J
E
C
T
I
O
N
EXIST. FNDN., SEE
SECTION
NOTE:*DIMENSIONS SHALL BE VERIFIED WITH SIGN
FRAME AND BASE PLATE PRIOR TO CONCRETE
PLACEMENT.NOTE:COORDINATE CONDUIT PLACEMENT INSIDE SIGN
BASE PRIOR TO CONCRETE PLACEMENT.
5 8" STEEL BASE
PLATE PER
MANUF.
(4) SLOTTED BOLT
HOLES (COORD. W/
SIGN PROVIDER)
8"
EQ EQ
8"
EQ
EQ1'
-
0
12"
1'-214"
8"
8"
FOUNDATION SECTION (PRE-BROWSE BOARD)
NOT TO SCALE
EXIST. REINF. TO REMAIN
FINISH GRADE
SIGNAGE FRAME,
COORD. W/ SUPPLIER
BASE PLATE PROVIDED
BY SIGN MANUF.
(4)- 3 4"Ø ALL-THREAD
EPOXY ANCHOR BOLTS
W/ HILTI HY200 EPOXY
OR APPROVED EQUAL
EXIST. CONC.
FOOTING TO REMAIN
REMOVE EXIST. BASE PLATE
AND CUT OFF EXIST. ANCHOR
BOLTS ABOVE EXIST. CONC.
FOOTING (F.V.)
ROUGHEN SURFACE AND
APPLY BONDING AGENT
(TYP.)
SEE TYPICAL
CONN. DETAIL
SECTION A-A
COMPACT SUBGRADE TO 95%
DRY DENSITY IN ACCORDANCE
W/ ASTM D698 (TYP.)
1'
-
0
"
EM
B
E
D
.
NOTE:CONCRETE FOUNDATION DEPTH SHALL MEET OR
EXCEED LOCAL FROST DEPTH REQUIREMENTS
2'
-
0
"
M
I
N
.
±
MA
T
C
H
E
X
I
S
T
.
3" CLR
4"
C
L
R
.
4"
C
L
R
.
NOTE:CONTRACTOR SHALL ADJUST SPACING AS REQ'D TO
AVOID EXIST. REINF. IF ENCOUNTERED. INDICATED
REINF. IS FOR ILLUSTRATION PURPOSES ONLY.
4'
-
1
5
8"
5'
-
1
1
5
8"
S
I
G
N
1'
-
1
0
"
PLAN VIEW
EXIST. CONC.
FOOTING TO
REMAIN (F.V.
SIZE AND DEPTH)
#5 DOWELS @ 12" O/C
(T&B) EA. SIDE. PROVIDE
4" MIN. EMBED. W/ HILTI
HY200 EPOXY OR EQUAL
(TYP.)
(1)-#5 CONT. (T&B)
AA
SIGN
ORIENTATION
ABOVE
4"
C
L
R
TY
P
.
2'-6" PRE-BROWSE BOARD SIGN
0'
-
8
"
±
MA
T
C
H
E
X
I
S
T
.
1'-1" MIN.
F.V.
5"5"
9"
9"
S1.0
PRE-BROWSE
BOARD
FOUNDATION
FI
L
E
N
A
M
E
:
N
:
\
_
S
i
g
n
F
o
u
n
d
a
t
i
o
n
s
\
S
t
a
r
b
u
c
k
s
\
2
0
2
4
-
4
0
3
3
\
D
W
G
\
S
t
r
u
c
t
S
C
C
1
0
0
0
5
,
S
a
n
t
a
A
n
n
a
,
C
A
.
d
w
g
L
A
Y
O
U
T
N
A
M
E
:
A
u
g
m
e
n
t
e
d
(
P
B
)
P
L
O
T
T
E
D
:
T
h
u
r
s
d
a
y
,
A
u
g
u
s
t
0
8
,
2
0
2
4
-
1
0
:
5
9
a
m
structural engineer
508 Baylor Court
Suite C
Chesapeake, Virginia 23320
757.436.2070
757.436.0610
www.broylesandassociates.com
Robert S. Whitaker, PE, SE
RE
V
DA
T
E
BY
DE
S
C
R
I
P
T
I
O
N
PROJECT
DATE
DESIGNED
DRAWN
CHECKED
BJB
24500-53
08/02/2024
RSW
SI
T
E
A
D
D
R
E
S
S
:
23
0
3
S
.
B
R
I
S
T
O
L
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
4
-
5
7
5
5
SC
C
1
0
0
0
5
(757)622-2828 / fax (757)622-6883
Chesapeake, VA 23320
1317 Executive Blvd, Suite 200
RRMM ®
COLLABORATIVE, INC.
ARCHITECTS
BJB
REG
ISTERED PROFESS IONAL ENGINEER
STATE OF CAL IFORNIACIVIL
R
OBERT S . W HITAKE
R
NO. 93116
2303 S Bristol St
Unit A11/13/2024
CONCRETE NOTES:
1.ALL FOOTINGS SHALL BEAR ON FIRM UNDISTURBED RESIDUAL SOIL AND/OR EARTH FILL COMPACTED TO 95% OF
ITS MAXIMUM DRY DENSITY AS PER ASTM D698 (STANDARD PROCTOR) UNLESS NOTED OTHERWISE.
CONTRACTOR SHALL CONFIRM SOIL CAPACITY PRIOR TO CONCRETE PLACEMENT.
2.ALL PIERS TO EXTEND TO FROST DEPTH AS DETERMINED BY LOCAL JURISDICTION. VERIFY WITH LOCAL BUILDING
OFFICIAL.
3.TOP OF PIERS SHALL BE SLOPED SUCH THAT MOISTURE CANNOT ACCUMULATE.
4.ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI 301 "STRUCTURAL CONCRETE FOR
BUILDINGS" AND ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE."
5.ALL CAST-IN-PLACE CONCRETE SHALL ATTAIN AN ULTIMATE COMPRESSIVE STRENGTH (fc) OF 3000 PSI AT AN
AGE OF 28 DAYS UNLESS OTHERWISE NOTED.
6.ALL REINFORCING STEEL SHALL BE ASTM A 615, GRADE 60 DEFORMED BARS, UNLESS OTHERWISE NOTED.
7.CONCRETE PROTECTION FOR REINFORCING AS WELL AS PLACING AND FABRICATION OF REINFORCING SHALL
BE IN ACCORDANCE WITH THE "THE AMERICAN CONCRETE INSTITUTE BUILDING CODE REQUIREMENTS" (ACI
318).
8.ALL CAST-IN-PLACE CONCRETE SHALL BE AIR-ENTRAINED TO 6% (±112%). WATER/CEMENT RATIO SHALL NOT
EXCEED 0.48.
9.THE MINIMUM CONCRETE COVER FOR THE PROTECTION OF REINFORCEMENT SHALL BE AS NOTED.
10.BEFORE PLACING CONCRETE, ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED,
AND MAINTAINED SECURELY IN PLACE. NO "WET SETTING" IS ALLOWED.
11.AGGREGATES IN NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C-33 (HARDROCK).
12.PORTLAND CEMENT SHALL BE TYPE II FOR ALL CONCRETE CONFORMING TO ASTM C150, LOW ALKALI.
13.FLY ASH OR OTHER POZZOLANS CONFORMING TO ASTM C618 CLASS N OR F MAY BE USED AS A PARTIAL
SUBSTITUTION FOR PORTLAND CEMENT UP TO A MAXIMUM OF 25% TOTAL CEMENTITIOUS MATERIALS BE WEIGHT
IF THE MIX DESIGN IS PROPORTIONED PER ACI318, SECTION 5.3. CONTRACTOR SHALL FORWARD DESIGN MIX
TO ARCHITECT AND STRUCTURAL ENGINEER OF RECORD.
14.CONCRETE MIXING OPERATIONS, ETC. SHALL CONFORM TO ASTM C94.
15.DO NOT USE ANY CONCRETE OR GROUT CONTAINING
CHLORIDES. WATER USED IN MIX SHALL BE CLEAN AND POTABLE.
HEAVY HEX
LEVELING NUT
(GALV.)
(2) HEAVY 3 4" HEX
TOP NUT (GALV.)
ADHESIVE ANCHOR
BOLT DETAIL
NOT TO SCALE
2"X2"X14" HEAVY
STEEL PLATE
WASHERS OR
212"Ø x 14" THK.
WASHER (GALV.)
3 4"Ø ALL-THREAD
RODS (GALV.)
1'
-
5
"
TYPICAL ANCHOR BOLT PATTERN
NOT TO SCALE
NOTE:IF BOLTS ARE CUT, CONTRACTOR SHALL PROVIDE
GALVANIZING SPRAY AT CUT BOLTS TO AVOID RUSTING.
TYPICAL SIGN BASE PLATE DETAIL
NOT TO SCALE
TYPICAL CONNECTION DETAIL
NOT TO SCALE
STEEL NOTES:
1.REINFORCEMENT: GRADE 60.
2.ANCHOR RODS, NUTS, AND WASHERS SHALL BE SHIPPED AS AN
ASSEMBLY FROM THE SIGN/LIGHTING MANUFACTURER. COORDINATE
WITH MANUFACTURER.
A. THREADED RODS: ASTM F1554, GRADE 36
B. PLATE WASHERS: ASTM A-36
C. WASHERS: ASTM F-436
D. NUTS: A563DH OR A194-2H
3.ALL HARDWARE SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM
A-123, HOT-DIP GALVANIZED, ZINC PLATED OR MECHANICALLY
GALVANIZED.
4.ANCHOR BOLTS TO BE SET IN ACCORDANCE WITH AISC CODE OF
STANDARD PRACTICE.
5.FIELD HEATING TO BEND STEEL SHALL NOT BE ALLOWED.
6.ANCHOR BOLTS TO BE CUT, IF NEEDED, TO 5". APPLY COLD
GALVANIZING TO CUT BOLT ENDS.
7.CONTRACTOR (INSTALLER) IS RESPONSIBLE FOR THE MEANS AND
METHODS OF CONSTRUCTION IN REGARDS TO JOBSITE SAFETY.
8.STRUCTURAL SIGN FRAME AND BASE PLATE DETAILS ARE PROVIDED BY
SIGN MANUFACTURER. COORDINATE ALL ATTACHMENTS OF SIGN
WITH MANUFACTURER. REFER TO SIGN MANUFACTURER DRAWINGS
AND INSTRUCTIONS FOR ADDITIONAL INFORMATION.
9.DO NOT CUT ANCHOR BOLTS OR RODS AFTER INSTALLATION OF
FRAME.
114"
M
A
X
.
TIGHTEN TOP NUTS 16 TURN
BEYOND HAND-TIGHT
(TURN OF NUT METHOD)
(MIN 60°, MAX 80°)
NOTE:THE DISTANCE FROM THE TOP OF THE
FOUNDATION TO THE BOTTOM OF THE BASE
PLATE SHALL BE NO GREATER THAN 114".
60°
FLAT WASHERS
5"
P
R
O
J
E
C
T
I
O
N
EXIST. FNDN., SEE
SECTION
NOTE:*DIMENSIONS SHALL BE VERIFIED WITH SIGN
FRAME AND BASE PLATE PRIOR TO CONCRETE
PLACEMENT.NOTE:COORDINATE CONDUIT PLACEMENT INSIDE SIGN
BASE PRIOR TO CONCRETE PLACEMENT.
5 8" STEEL BASE
PLATE PER
MANUF.
(4) SLOTTED BOLT
HOLES (COORD. W/
SIGN PROVIDER)
8"
EQ EQ
8"
EQ
EQ1'
-
0
12"
1'-214"
8"
8"
FOUNDATION SECTION (MENU BOARD)
NOT TO SCALE
EXIST. REINF. TO REMAIN
FINISH GRADE
SIGNAGE FRAME,
COORD. W/ SUPPLIER
BASE PLATE PROVIDED
BY SIGN MANUF.
(4)- 3 4"Ø ALL-THREAD
EPOXY ANCHOR BOLTS
W/ HILTI HY200 EPOXY
OR APPROVED EQUAL
EXIST. CONC.
FOOTING TO REMAIN
REMOVE EXIST. BASE PLATE
AND CUT OFF EXIST. ANCHOR
BOLTS ABOVE EXIST. CONC.
FOOTING (F.V.)
ROUGHEN SURFACE AND
APPLY BONDING AGENT
(TYP.)
SEE TYPICAL
CONN. DETAIL
SECTION A-A
COMPACT SUBGRADE TO 95%
DRY DENSITY IN ACCORDANCE
W/ ASTM D698 (TYP.)
1'
-
0
"
EM
B
E
D
.
3'-2"±
MATCH EXIST.
EXIST. CONC.
FOOTING TO
REMAIN (F.V.
SIZE AND
DEPTH)
#5 DOWELS @ 12" O/C
(T&B) EA. SIDE. PROVIDE
4" MIN. EMBED. W/ HILTI
HY200 EPOXY OR EQUAL
(TYP.)
(1)-#5 CONT. (T&B)
PLAN VIEW
A
A
SIGN
ORIENTATION
ABOVE
1'
-
7
"
M
I
N
.
FI
E
L
D
V
E
R
I
F
Y
4'-10" MENU BOARD SIGN
NOTE:CONCRETE FOUNDATION DEPTH SHALL MEET OR
EXCEED LOCAL FROST DEPTH REQUIREMENTS
2'
-
0
"
M
I
N
.
±
MA
T
C
H
E
X
I
S
T
.
3" CLR
4"
C
L
R
.
4"
C
L
R
.
NOTE:CONTRACTOR SHALL ADJUST SPACING AS REQ'D TO
AVOID EXIST. REINF. IF ENCOUNTERED. INDICATED
REINF. IS FOR ILLUSTRATION PURPOSES ONLY.
5"
5"
4" CLR
TYP.
4'
-
1
5
8"
5'
-
1
1
5
8"
S
I
G
N
1'
-
1
0
"
GENERAL NOTES:
1.THE FOLLOWING CODES WERE USED IN DESIGN:
2022 CALIFORNIA BUILDING STANDARDS CODE (TITLE 24, PART 2), IBC 2021 AND ASCE-7 (2016).
2.STRUCTURAL LOADINGS:
WIND:
WIND (3 SECOND GUST)...........................................VULT = 100MPH
VASD = 78 MPH
EXPOSURE...........................................................................C
RISK CATEGORY.................................................................II
WIND BASE SHEAR.......................................................Vb = 690 LBS (MENU BOARD)
SEISMIC:
SEISMIC IMPORTANCE FACTOR (Ie).................................1.0
MAPPED SPECTRAL RESPONSE ACCELERATIONS..Ss.......1.293g
S1........0.461g
DESIGN SPECTRAL RESPONSE ACCELERATIONS SDS......1.034g
SD1......0.565g
SITE CLASS...........................................................................D
SEISMIC DESIGN CATEGORY.............................................D
SEISMIC RESPONSE COEFFICIENT (CS)..............................0.296
COMPONENT RESPONSE MODIFICATION FACTOR (RP)..3.5
SEISMIC DESIGN FORCE (FP)..............................................0.22 KIPS (MENU BOARD)
FROST DEPTH...............................................................................0'-6"
3.ALL FOOTING EXCAVATIONS ARE TO BE CLEAR OF WATER AND FOREIGN MATTER BEFORE PLACING CONCRETE.
4.PRESUMPTIVE MINIMUM ALLOWABLE LATERAL SOIL BEARING PRESSURE (So) OF 100 PSF. CONTRACTOR SHALL
CONFIRM AN ALLOWABLE BEARING PRESSURE (Sb) OF 1500 PSF. ALLOWABLE BEARING PRESSURE SHALL BE
VERIFIED BY CONTRACTOR PRIOR TO CONCRETE PLACEMENT.
5.FOUNDATION SHALL NOT BE PLACED ON OR AT THE TOP OF A SLOPE EXCEEDING 3:1 WITHOUT EVALUATION BY A
PROFESSIONAL LICENSED IN THAT STATE. DO NOT PLACE FOUNDATION IN FILL MATERIAL.
6.DEPTH OF PIER FOUNDATIONS MAY BE LOWERED IF NEEDED TO OBTAIN LOCAL FROST DEPTH ELEVATIONS OR IF
REQUIRED DUE TO POOR SOIL CONDITIONS. VERIFY FROST DEPTH ELEVATIONS WITH LOCAL CODE OFFICIAL.
7.ELECTRICAL CONTRACTOR TO PROVIDE INFORMATION ON CONDUIT AND ELECTRICAL REQUIREMENTS AND
CONTRACTOR (INSTALLER) SHALL COORDINATE PLACEMENT TO MAINTAIN 2" CLEAR TO ANCHOR BOLTS.
8.COORDINATE LOCATIONS OF SIGNS AND FOUNDATIONS WITH SITE PLAN.
9.CONTRACTOR SHALL CUT EXCESS SONOTUBE FROM AROUND THE PERIMETER OF THE PIER FOUNDATION AFTER
PLACEMENT OF BOARD (PRIOR TO LEAVING SITE).
10.CONTRACTOR SHALL NOT DEVIATE FROM STRUCTURAL DRAWING WITHOUT PRIOR WRITTEN CONSENT AND
INSTRUCTIONS REGARDING ANY CHANGE TO THE CONTRACT DRAWINGS. ANY DEVIATION FROM THIS DESIGN
OR FROM ANY PART OF THIS DRAWING WITHOUT PRIOR WRITTEN CONSENT OF THIS ENGINEER SHALL VOID ALL
LIABILITY ASSOCIATED WITH THIS WORK.
11.SPECIAL INSPECTIONS ARE NOT REQUIRED FOR THESE SIGN FOUNDATIONS.
S2.0
MENU BOARD
FOUNDATION
FI
L
E
N
A
M
E
:
N
:
\
_
S
i
g
n
F
o
u
n
d
a
t
i
o
n
s
\
S
t
a
r
b
u
c
k
s
\
2
0
2
4
-
4
0
3
3
\
D
W
G
\
S
t
r
u
c
t
S
C
C
1
0
0
0
5
,
S
a
n
t
a
A
n
n
a
,
C
A
.
d
w
g
L
A
Y
O
U
T
N
A
M
E
:
A
u
g
m
e
n
t
e
d
(
M
B
)
P
L
O
T
T
E
D
:
T
h
u
r
s
d
a
y
,
A
u
g
u
s
t
0
8
,
2
0
2
4
-
1
1
:
0
0
a
m
structural engineer
508 Baylor Court
Suite C
Chesapeake, Virginia 23320
757.436.2070
757.436.0610
www.broylesandassociates.com
Robert S. Whitaker, PE, SE
RE
V
DA
T
E
BY
DE
S
C
R
I
P
T
I
O
N
PROJECT
DATE
DESIGNED
DRAWN
CHECKED
BJB
24500-53
08/02/2024
RSW
SI
T
E
A
D
D
R
E
S
S
:
23
0
3
S
.
B
R
I
S
T
O
L
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
4
-
5
7
5
5
SC
C
1
0
0
0
5
(757)622-2828 / fax (757)622-6883
Chesapeake, VA 23320
1317 Executive Blvd, Suite 200
RRMM ®
COLLABORATIVE, INC.
ARCHITECTS
BJB
REG
ISTERED PROFESS IONAL ENGINEER
STATE OF CAL IFORNIACIVIL
R
OBERT S . W HITAKE
R
NO. 93116
2303 S Bristol St
Unit A11/13/2024
r-, coatesL.J
2303 S Bristol St
Unit A11/13/2024
Coates Outdoor Digital Menuboards
2303 S Bristol St
Unit A11/13/2024
[740.00] 29.1
[347.16] 13.7
[1815.02] 71.5
Single unit dimensions 2303 S Bristol St
Unit A11/13/2024
[1472.00] 58.0
[347.17] 13.7
[1815.01] 71.5
Double unit dimensions 2303 S Bristol St
Unit A11/13/2024
Note: These numbers are maximum current draw to be allowed for, and are not an indication of power consumption over time.
Max potential power consumption is 2.6 Amps max @220V Max potential power consumption is 4.9 Amps max @220V
Power draw 2303 S Bristol St
Unit A11/13/2024
Area of a single active display 1.64m²
Area of screen with bezel display 1.84m²
Active display area 2303 S Bristol St
Unit A11/13/2024
Area of a single active display 0.82m²
Area of screen with bezel display 0.92m²
Active display area 2303 S Bristol St
Unit A11/13/2024
85 [3,3]
1260.6 [49,6]
Samsung 55OHF
Diagonal Size
Brightness
Weight
Mechanical
Specification
Glass
Bezel Width
Operation
Temperature
Certification
55"
2500 NIT
52.6 Kg [118.2 lbs]
5T Tempered Glass
24.9mm [0.98"]
-30℃ ~ 50 ℃ [-40 F ~ 122 F]
UL : CUL60950-1 (GO)
Screen info 2303 S Bristol St
Unit A11/13/2024
Light output 2303 S Bristol St
Unit A11/13/2024
Unit powder coat colour - Coates drak grey
RAL - 9004
Gloss specification 5-8 untis @60deg
Unti colour 2303 S Bristol St
Unit A11/13/2024
Planning & Building Agency
Building Agency Division
20 Civic Center Plaza
P.O Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
CITY OF SANTA ANA
PLAN CHECK - CHECKLIST
JOB ADDRESS:
TRACKING #:DATE:
FOR PLAN CHECK STATUS
Visit http://www.santa-ana.org/pb or Call (714) 647-5800
PLEASE READ AND INITIAL EACH ITEM BELOW
1.
I agree to pay a plancheck fee established for this project with the understanding that this
payment is not a guarantee that a permit will be issued and that this fee is not refundable
once a plancheck has commenced.
2.
I understand that I may request an "Accelerated Plancheck" at an additional cost. This
plan check may be performed at an additional cost with the intention of reducing plancheck
time for the Building & Safety Division.
3.I understand that the project valuation will be reviewed during the plancheck process and
that said valuation shall be adjusted up or down in accordance with established fee
computation regulations.
4.I understand that I shall submit separate plans, applications and plancheck fees for
Mechanical, Electrical, Plumbing, Solar and Grading when plan check is required.
5.I understand that prior to the issuance of the Building Permit, I am required to obtain
Public Works Agency approval if any of the following apply: project valuation exceeds
$30,000; project has added plumbing fixtures; added bedrooms, or project exceeds 500 sq. ft.
6.I understand that prior to the issuance of the Building Permit, I am required to obtain
Public Works Agency approval if my project valuation exceeds $50,000 and that a
backflow device may be required. Please call (714) 647-3320 for further information.
AGREED TO BY APPLICANT OR AGENT
Applicant’s Signature:
Print Name:Address:
Telephone Number:Email:
FOR OFFICE USE ONLY: "Checklist of items discussed" APPROVALS & FEES REQUIRED
1. Planning Department (714) 647-5804 8. Title 24 (Disabled Access)15. SMIPFee
2.Public Works Agency (714) 647-5074 9. Title 24 (Energy)16. Microfilming/scanningFee
3.Fire Department (714) 573-6100 10. Roof MountedEquip.17. Res.Dev.Fees
4.Police De artment (714) 647-5840 11. GreaseInterceptor 18. FCWPSurchargeFee
5.School District 12. Listof Subcontractors 19. FireFacilityFee
6.Health De artment 13. Const.DebrisRecyc.20. SouthCoastAQMD
7.OC Sanitation District 14. LOA/Owner-BuilderVer.
PERMIT TECHNICIAN
Rev. 11/4/22
2303 S Bristol St
Unit A11/13/2024
508 Baylor Court, Suite C
Chesapeake, VA 23220
757.436.2070
Charles Town, WV
304.370.3088
Prepared by:
Broyles and Associates, P.C.
508 Baylor Ct, Suite C
Chesapeake, VA 23220
757.436.2070 • 304.370.3088 • dbroyles@broylesandassociates.com • www.broylesandassociates.com
STRUCTURAL CALCULATIONS
COVER SHEET
Starbucks Menu Board Foundations
Santa Ana, CA
Foundation Calculations
August 2, 2024
Prepared for:
RRMM
1317 Executive Blvd,
Chesapeake, VA 23320
2303 S Bristol St
Unit A11/13/2024
Broyles And Associates
508 Baylor Court, Suite C
Chesapeake, Virgnia 23320
PH: 757-436-2070
Project
Starbucks
Job Ref.
Section
115 MPH Sign Foundation Design
Sheet no./rev.
1
Calc. by
RSW
Date
2021/30/2024
4
Chk'd by
Date
App'd by
Date
DESIGN CRITERIA – ASCE 7-16
Wind Design
Wind Speed V = 115 MPH
Risk Category II
Exposure Category C
Foundation Design
Presumptive Soil Bearing Q = 1500 psf
Concrete Strength fc = 3000 psi
Concrete anchors ASTM F1554 A36 fy = 36 ksi
Dimensional Information
Overall Sign Height (both) h = 6.0 ft
Single Menu Board: Sign Height hs = 4.17 ft
Sign Width bs = 2.5 ft
Height of Centerline hsc = h - hs/2 = 4.0 ft
Double Menu Board: Sign Height hd = 4.17 ft
Sign Width bd = 4.83 ft
Height of Centerline hdc = h - hd/2 = 4.0 ft
Embedment calculation uses ASD loads = 0.6* Ult = 370# * 0.6 = 222#
WIND LOADING DOUBLE MENU BOARD (ASCE7-16)
WIND LOADING
In accordance with ASCE7-16
Using the directional design method
Tedds calculation version 2.1.13
Wall/sign data
Length of wall/sign B = 4.83 ft
Height of wall/sign s = 4.17 ft
Height to top of sign h = 6.00 ft
General wind load requirements
Basic wind speed V = 115.0 mph
Risk category II
Velocity pressure exponent coef (Table 26.6-1) Kd = 0.85
Ground elevation above sea level zgl = 0 ft
Ground elevation factor Ke = exp(-0.0000362 zgl/1ft) = 1.00
Exposure category (cl 26.7.3) C
2303 S Bristol St
Unit A11/13/2024
Broyles And Associates
508 Baylor Court, Suite C
Chesapeake, Virgnia 23320
PH: 757-436-2070
Project
Starbucks
Job Ref.
Section
115 MPH Sign Foundation Design
Sheet no./rev.
2
Calc. by
RSW
Date
2021/30/2024
4
Chk'd by
Date
App'd by
Date
Gust effect factor Gf = 0.85
Minimum design wind loading (cl.27.1.5) pmin_r = 8 lb/ft2
Topography
Topography factor not significant Kzt = 1.0
Velocity pressure
Velocity pressure coefficient (Table 26.10-1) Kz = 0.85
Velocity pressure qh = 0.00256 Kz Kzt Kd Ke V2 1psf/mph2 = 24.5 psf
Area of sign Af = B s = 20.141 ft2
Ratio of solid area to gross area = 1.00
Wall/sign forces – Case A and B
Force coefficient (Figure 29.3-1) Cf_A = 1.64
Resultant force FA = max(16psf, qh Gf Cf_A) Af = 0.7 kips
Embedment calculation uses ASD loads = 0.6* Ult = 690# * 0.6 = 414#
2303 S Bristol St
Unit A11/13/2024
Project:Sign Designs Proj No:
Prepared By:RSW Date:8/6/24
Checked By: Sheet No:
Subject:
ASCE 7 Wind Loads Last updated:07/30/24
Directional Procedure
Square Footing Loading (at top of ftg)
Vol. of conc.:15.3 ft^3 V ULT=690 # (at center)
w conc=150 pcf V = 0.6 VULT=414 # (at center)130.7
f'c=3000 psi P =300 # (at center)94.7
fy=60000 psi M =1656 ft-# (at center)522.9
e =0 in
Soil Sign Base Steel
k=90 pci Modulus of Subgrade reaction 12 ''x 14" baseplate
Soil angle:30 0.524 rad
Soil weight:110 pcf Footing W min = Pwall/ Qnet = 0.06ft
Q-net allow:1500 psf net allowable bearing Ftg width x length:3.167 2.417
Soil depth abv:0 in Ftg depth:24 in
Weight:0 plf Weight:725 plf
Cover to ties:3''As tie=0.028 in^2
Increase Soil Bearing Pressure?d=20.8125''0.028
Use soil wt?in Q-net 0 As min long= 1.253 in^2
Soil weight:0 # (per foot)
Use ftg wt?yes 1
Ftg weight:725 # (per foot)
P tot design=819.7 # (per foot)MRESIST = 3136.6ft-#MOT= 2483.6 ft-#
e=M/P tot=0.64 ft (outside kern)1' strip MRESIST = 990.5ft-# / ft MOT= 784.3 ft-#
e > b/6=0.4 :. Q=4/3*P/(L(B-2*e))
Qmax=962 psf < 1800 psf gross +/-
Qmin=0 psf 1800
Assuming soil resulantant is located at "e"
Soil load width x=3(B/2-e)=20.46
Overturning and Sliding
Use soil wt?yes 1
Soil weight:0 # (per foot)
Use ftg wt?yes 1
Ftg weight:725 # (per foot)Footing Design Load factor=1.4
P tot Design=819.7 # (per foot)Bending:Lcr =8.5''from edge of ftg
2595.7 # total M pressure=208 ft-#
Slide frict=221 # friction Mu=1.4*Mp=291 ft-#
tan(o/2)=0.27 Shear:Lcr =0''from edge of ftg
Slide soil=0 # side soil V pressure=0 #
S Resist Total=221 # / ft length Vu=1.4*Vp=0 #
Slide FS =1.69 > 1.25
M resist=P tot*(width/2)=3136.6 ft-#Reinforced Footing Design:
=990.5 ft-# / ft ФMoment =0.9 ФShear =0.75
OT FS =1.26 > 1.25 Transverse ties:# 3 at 48'' oc
a=0.055 As tie=0.028 in^2
Unreinforced Footing Design:Ф =0.55 c=0.065 < 0.375*d=7.805
ФMn=Ф*5sqrt(f'c)(b*d^2/6)=10874 ft-# > 291ft-#ФMn=Ф*As*fy*(d-a/2)=2619 ft-# > 291ft-#
ФVn=Ф*4/3*sqrt(f'c)*b*h=11568 # > 0#ФVn=Ф*2*sqrt(f'c)*b*d=20519 # > 0#
0
2.417 ft x 3.167 ft x 24'' column footing is acceptable as an unreinforced footing.
Orig. size = 38''x 19''x 24''
| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| |
E| | E| | E| |E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E
0
8.5
0
962
562 962
8.5''
0''
M
P
V
128.5
24
0
/ft
/ft
/ft
/ft
ft x ft
20.46
NWIND
5''5''
2303 S Bristol St
Unit A11/13/2024
www.hilti.com
Hilti PROFIS Engineering 3.1.1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Company:
Address:
Phone I Fax:
Design:
Fastening point:
|
WIND - Concrete - Jul 23, 2024
Page:
Specifier:
E-Mail:
Date:
1
7/30/2024
Specifier's comments:
1 Input data
Anchor type and diameter: HIT-HY 200 V3 + HAS-V-36 (ASTM F1554 Gr.36) 3/4
Item number: 2198030 HAS-V-36 3/4"x10" (element) / 2334276 HIT-HY
200-R V3 (adhesive)
Specification text: Hilti HAS threaded rod with HIT-HY 200 V3
injection mortar with 6 in embedment hef, 3/4,
Carbon steel, Safe Set System, Hammer
drilled installation per ESR-4868
WIND LOAD
Effective embedment depth: hef,act = 6.000 in. (hef,limit = - in.)
Material: ASTM F1554 Grade 36
Evaluation Service Report: ESR-4868
Issued I Valid: 11/1/2022 | 11/1/2024
Proof: Design Method ACI 318-19 / Chem
Stand-off installation: without clamping (anchor); restraint level (anchor plate): 1.00; eb = 1.000 in.; t = 0.500 in.
Anchor plateR : lx x ly x t = 20.000 in. x 20.000 in. x 0.500 in.; (Recommended plate thickness: not calculated)
Profile: Round HSS (AISC), HSS1.66X.140; (L x W x T) = 1.660 in. x 1.660 in. x 0.140 in.
Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 7.750 in., Temp. short/long: 32/32 °F
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar
R - The anchor calculation is based on a rigid anchor plate assumption.
Geometry [in.] & Loading [lb, in.lb]
Menu Board Anchors (Pre-Browse are similar)
Sign Foundation
NOTE: GEOMETRY OF
THE FOUNDATION AND
ANCHOR EMBEDMENT
SHOWN ARE
CONSERVATIVE FOR
ACTUAL CONDITIONS.
2303 S Bristol St
Unit A11/13/2024
www.hilti.com
Hilti PROFIS Engineering 3.1.1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Company:
Address:
Phone I Fax:
Design:
Fastening point:
|
WIND - Concrete - Jul 23, 2024
Page:
Specifier:
E-Mail:
Date:
2
7/30/2024
1.1 Design results
Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%]
1 Combination 1 N = -300; Vx = 0; Vy = -690;
Mx = 33,120; My = 0; Mz = 0;
no 55
2 Load case/Resulting anchor forces
Anchor reactions [lb]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 -2,145 172 0 -172
2 -2,145 172 0 -172
3 1,995 172 0 -172
4 1,995 172 0 -172
max. concrete compressive strain: - [‰]
max. concrete compressive stress: - [psi]
resulting tension force in (x/y)=(-0.000/4.000): 3,990 [lb]
resulting compression force in (x/y)=(-0.000/-4.000): 4,290 [lb]
Anchor forces are calculated based on the assumption of a rigid anchor plate.
3 Tension load
Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status
Steel Strength*-2,145 14,550 15 OK
Bond Strength**3,990 7,432 54 OK
Sustained Tension Load Bond Strength*N/A N/A N/A N/A
Concrete Breakout Failure**3,990 7,367 55 OK
* highest loaded anchor **anchor group (anchors in tension)
2303 S Bristol St
Unit A11/13/2024
www.hilti.com
Hilti PROFIS Engineering 3.1.1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Company:
Address:
Phone I Fax:
Design:
Fastening point:
|
WIND - Concrete - Jul 23, 2024
Page:
Specifier:
E-Mail:
Date:
3
7/30/2024
3.1 Steel Strength
Nsa = ESR value refer to ICC-ES ESR-4868
f Nsa ³ Nua ACI 318-19 Table 17.5.2
Variables
Ase,N [in.2]futa [psi]
0.33 58,000
Calculations
Nsa [lb]
19,400
Results
Nsa [lb]f steel f Nsa [lb]Nua [lb]
19,400 0.750 14,550 -2,145
The steel proof was done for the highest absolute force per anchor - in this case compression loading. Please be aware that buckling should
be verified separately
2303 S Bristol St
Unit A11/13/2024
www.hilti.com
Hilti PROFIS Engineering 3.1.1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Company:
Address:
Phone I Fax:
Design:
Fastening point:
|
WIND - Concrete - Jul 23, 2024
Page:
Specifier:
E-Mail:
Date:
4
7/30/2024
3.2 Bond Strength
Nag = (ANa
ANa0)y ec1,Na y ec2,Na y ed,Na y cp,Na Nba ACI 318-19 Eq. (17.6.5.1b)
f Nag ³ Nua ACI 318-19 Table 17.5.2
ANa see ACI 318-19, Section 17.6.5.1, Fig. R 17.6.5.1(b)
ANa0 = (2 cNa)2 ACI 318-19 Eq. (17.6.5.1.2a)
cNa = 10 da √t uncr
1100 ACI 318-19 Eq. (17.6.5.1.2b)
y ec,Na = (1
1 + e'
N
cNa
)£ 1.0 ACI 318-19 Eq. (17.6.5.3.1)
y ed,Na = 0.7 + 0.3 (ca,min
cNa )£ 1.0 ACI 318-19 Eq. (17.6.5.4.1b)
y cp,Na = MAX(ca,min
cac
, cNa
cac )£ 1.0 ACI 318-19 Eq. (17.6.5.5.1b)
Nba = l a · t k,c · p · da · hef ACI 318-19 Eq. (17.6.5.2.1)
Variables
t k,c,uncr [psi]da [in.]hef [in.]ca,min [in.]aoverhead t k,c [psi]
2,220 0.750 6.000 6.000 1.000 1,260
ec1,N [in.]ec2,N [in.]cac [in.]l a
0.000 0.000 13.564 1.000
Calculations
cNa [in.]ANa [in.2]ANa0 [in.2]y ed,Na
10.607 332.13 450.00 0.870
y ec1,Na y ec2,Na y cp,Na Nba [lb]
1.000 1.000 1.000 17,813
Results
Nag [lb]f bond f Nag [lb]Nua [lb]
11,434 0.650 7,432 3,990
2303 S Bristol St
Unit A11/13/2024
www.hilti.com
Hilti PROFIS Engineering 3.1.1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Company:
Address:
Phone I Fax:
Design:
Fastening point:
|
WIND - Concrete - Jul 23, 2024
Page:
Specifier:
E-Mail:
Date:
5
7/30/2024
3.3 Concrete Breakout Failure
Ncbg = (ANc
ANc0)y ec,N y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1b)
f Ncbg ³ Nua ACI 318-19 Table 17.5.2
ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
ANc0 = 9 h2
ef ACI 318-19 Eq. (17.6.2.1.4)
y ec,N = (1
1 + 2 e'
N
3 hef
)£ 1.0 ACI 318-19 Eq. (17.6.2.3.1)
y ed,N = 0.7 + 0.3 (ca,min
1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b)
y cp,N = MAX(ca,min
cac
, 1.5hef
cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b)
Nb = kc l a √f'
c h1.5
ef ACI 318-19 Eq. (17.6.2.2.1)
Variables
hef [in.]ec1,N [in.]ec2,N [in.]ca,min [in.]y c,N
4.000 0.000 0.000 6.000 1.000
cac [in.]kc l a f'
c [psi]
13.564 17 1.000 2,500
Calculations
ANc [in.2]ANc0 [in.2]y ec1,N y ec2,N y ed,N y cp,N Nb [lb]
240.00 144.00 1.000 1.000 1.000 1.000 6,800
Results
Ncbg [lb]f concrete f Ncbg [lb]Nua [lb]
11,333 0.650 7,367 3,990
2303 S Bristol St
Unit A11/13/2024
www.hilti.com
Hilti PROFIS Engineering 3.1.1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Company:
Address:
Phone I Fax:
Design:
Fastening point:
|
WIND - Concrete - Jul 23, 2024
Page:
Specifier:
E-Mail:
Date:
6
7/30/2024
4 Shear load
Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status
Steel Strength*172 7,566 3 OK
Steel failure (with lever arm)*172 648 27 OK
Pryout Strength (Bond Strength controls)**690 19,279 4 OK
Concrete edge failure in direction y-**690 4,450 16 OK
* highest loaded anchor **anchor group (relevant anchors)
4.1 Steel Strength
Vsa = ESR value refer to ICC-ES ESR-4868
f Vsteel ³ Vua ACI 318-19 Table 17.5.2
Variables
Ase,V [in.2]futa [psi]
0.33 58,000
Calculations
Vsa [lb]
11,640
Results
Vsa [lb]f steel f Vsa [lb]Vua [lb]
11,640 0.650 7,566 172
2303 S Bristol St
Unit A11/13/2024
www.hilti.com
Hilti PROFIS Engineering 3.1.1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Company:
Address:
Phone I Fax:
Design:
Fastening point:
|
WIND - Concrete - Jul 23, 2024
Page:
Specifier:
E-Mail:
Date:
7
7/30/2024
4.2 Steel failure (with lever arm)
VM
s = aM · Ms
Lb
bending equation for stand-off
Ms = M0
s (1 - Nuaf Nsa) resultant flexural resistance of anchor
M0
s = (1.2) (S) (fu,min) characteristic flexural resistance of anchor
(1 - Nuaf Nsa) reduction for tensile force acting simultaneously with a shear force on the anchor
S = p(d)3
32 elastic section modulus of anchor bolt at concrete surface
Lb = z + (n)(d0) internal lever arm adjusted for spalling of the surface concrete
f VM
s ³ Vua ACI 318-19 Table 17.5.2
Variables
aM fu,min [psi]Nua [lb]f Nsa [lb]z [in.]n d0 [in.]
1.00 58,000 -2,145 14,550 1.250 0.500 0.750
Calculations
M0
s [in.lb](1 - Nuaf Nsa)Ms [in.lb]Lb [in.]
1,899 0.853 1,619 1.625
Results
VM
s [lb]f steel f VM
s [lb]Vua [lb]
996 0.650 648 172
2303 S Bristol St
Unit A11/13/2024
www.hilti.com
Hilti PROFIS Engineering 3.1.1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Company:
Address:
Phone I Fax:
Design:
Fastening point:
|
WIND - Concrete - Jul 23, 2024
Page:
Specifier:
E-Mail:
Date:
8
7/30/2024
4.3 Pryout Strength (Bond Strength controls)
Vcpg =kcp[(ANa
ANa0)y ec1,Na y ec2,Na y ed,Na y cp,Na Nba ] ACI 318-19 Eq. (17.7.3.1b)
f Vcpg ³ Vua ACI 318-19 Table 17.5.2
ANa see ACI 318-19, Section 17.6.5.1, Fig. R 17.6.5.1(b)
ANa0 = (2 cNa)2 ACI 318-19 Eq. (17.6.5.1.2a)
cNa = 10 da √t uncr
1100 ACI 318-19 Eq. (17.6.5.1.2b)
y ec,Na = (1
1 + e'
N
cNa
)£ 1.0 ACI 318-19 Eq. (17.6.5.3.1)
y ed,Na = 0.7 + 0.3 (ca,min
cNa )£ 1.0 ACI 318-19 Eq. (17.6.5.4.1b)
y cp,Na = MAX(ca,min
cac
, cNa
cac )£ 1.0 ACI 318-19 Eq. (17.6.5.5.1b)
Nba = l a · t k,c · p · da · hef ACI 318-19 Eq. (17.6.5.2.1)
Variables
kcp aoverhead t k,c,uncr [psi]da [in.]hef [in.]ca,min [in.]t k,c [psi]
2 1.000 2,220 0.750 6.000 6.000 1,260
ec1,N [in.]ec2,N [in.]cac [in.]l a
0.000 0.000 13.564 1.000
Calculations
cNa [in.]ANa [in.2]ANa0 [in.2]y ed,Na
10.607 400.00 450.00 0.870
y ec1,Na y ec2,Na y cp,Na Nba [lb]
1.000 1.000 1.000 17,813
Results
Vcpg [lb]f concrete f Vcpg [lb]Vua [lb]
27,541 0.700 19,279 690
2303 S Bristol St
Unit A11/13/2024
www.hilti.com
Hilti PROFIS Engineering 3.1.1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
Company:
Address:
Phone I Fax:
Design:
Fastening point:
|
WIND - Concrete - Jul 23, 2024
Page:
Specifier:
E-Mail:
Date:
9
7/30/2024
4.4 Concrete edge failure in direction y-
Vcbg = (AVc
AVc0)y ec,V y ed,V y c,V y h,V y parallel,V Vb ACI 318-19 Eq. (17.7.2.1b)
f Vcbg ³ Vua ACI 318-19 Table 17.5.2
AVc see ACI 318-19, Section 17.7.2.1, Fig. R 17.7.2.1(b)
AVc0 = 4.5 c2
a1 ACI 318-19 Eq. (17.7.2.1.3)
y ec,V = (1
1 + e'
v
1.5ca1
)£ 1.0 ACI 318-19 Eq. (17.7.2.3.1)
y ed,V = 0.7 + 0.3(ca2
1.5ca1)£ 1.0 ACI 318-19 Eq. (17.7.2.4.1b)
y h,V = √1.5ca1
ha
³ 1.0 ACI 318-19 Eq. (17.7.2.6.1)
Vb = 9 l a √f'
c c1.5
a1 ACI 318-19 Eq. (17.7.2.2.1b)
Variables
ca1 [in.]ca2 [in.]ecV [in.]y c,V ha [in.]
5.167 6.000 0.000 1.000 7.750
le [in.]l a da [in.]f'
c [psi]y parallel,V
6.000 1.000 0.750 2,500 1.000
Calculations
AVc [in.2]AVc0 [in.2]y ec,V y ed,V y h,V Vb [lb]
155.00 120.12 1.000 0.932 1.000 5,285
Results
Vcbg [lb]f concrete f Vcbg [lb]Vua [lb]
6,357 0.700 4,450 690
5 Combined tension and shear loads, per ACI 318-19 section 17.8
bN bV z Utilization bN,V [%]Status
0.542 0.266 5/3 48 OK
bNV = bz
N + bz
V <= 1
2303 S Bristol St
Unit A11/13/2024
www.hilti.com
Hilti PROFIS Engineering 3.1.1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
10
Company:
Address:
Phone I Fax:
Design:
Fastening point:
|
WIND - Concrete - Jul 23, 2024
Page:
Specifier:
E-Mail:
Date:
10
7/30/2024
6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The
proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
• Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential
concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout
or pryout strength governs.
• ACI 318 does not specifically address anchor bending when a stand-off condition exists. PROFIS Engineering calculates a shear load
corresponding to anchor bending when stand-off exists and includes the results as a shear Design Strength!
• Design Strengths of adhesive anchor systems are influenced by the cleaning method. Refer to the INSTRUCTIONS FOR USE given in the
Evaluation Service Report for cleaning and installation instructions.
• For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/
• Attention! In case of compressive anchor forces a buckling check as well as the proof of the local load transfer into and within the base material
(incl. punching) has to be done separately.
• Installation of Hilti adhesive anchor systems shall be performed by personnel trained to install Hilti adhesive anchors. Reference ACI 318-19,
Section 26.7.
Fastening meets the design criteria!
2303 S Bristol St
Unit A11/13/2024
www.hilti.com
Hilti PROFIS Engineering 3.1.1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
11
Company:
Address:
Phone I Fax:
Design:
Fastening point:
|
WIND - Concrete - Jul 23, 2024
Page:
Specifier:
E-Mail:
Date:
11
7/30/2024
Coordinates Anchor [in.]
Anchor x y c-x c+x c-y c+y
1 -4.000 -4.000 6.000 14.000 6.000 14.000
2 4.000 -4.000 14.000 6.000 6.000 14.000
3 -4.000 4.000 6.000 14.000 14.000 6.000
4 4.000 4.000 14.000 6.000 14.000 6.000
7 Installation data
Anchor type and diameter: HIT-HY 200 V3 + HAS-V-36
(ASTM F1554 Gr.36) 3/4
Profile: Round HSS (AISC), HSS1.66X.140; (L x W x T) = 1.660 in. x 1.660 in.
x 0.140 in.
Item number: 2198030 HAS-V-36 3/4"x10" (element) /
2334276 HIT-HY 200-R V3 (adhesive)
Hole diameter in the fixture: df = 0.812 in. Maximum installation torque: 1,200 in.lb
Plate thickness (input): 0.500 in. Hole diameter in the base material: 0.875 in.
Recommended plate thickness: not calculated Hole depth in the base material: 6.000 in.
Drilling method: Hammer drilled Minimum thickness of the base material: 7.750 in.
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required
Hilti HAS threaded rod with HIT-HY 200 V3 injection mortar with 6 in embedment hef, 3/4, Carbon steel, Safe Set System, Hammer drilled
installation per ESR-4868
7.1 Recommended accessories
Drilling Cleaning Setting
• Suitable Rotary Hammer
• Properly sized drill bit
• Compressed air with required accessories
to blow from the bottom of the hole
• Proper diameter wire brush
• Dispenser including cassette and mixer
• Torque wrench
2303 S Bristol St
Unit A11/13/2024
www.hilti.com
Hilti PROFIS Engineering 3.1.1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
12
Company:
Address:
Phone I Fax:
Design:
Fastening point:
|
WIND - Concrete - Jul 23, 2024
Page:
Specifier:
E-Mail:
Date:
12
7/30/2024
8 Remarks; Your Cooperation Duties
• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each
case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data
or programs, arising from a culpable breach of duty by you.
2303 S Bristol St
Unit A11/13/2024
Broyles And Associates
508 Baylor Court, Suite C
Chesapeake, Virgnia 23320
PH: 757-436-2070
Project
Starbucks
Job Ref.
Section
115 MPH Sign Foundation Design
Sheet no./rev.
1
Calc. by
RSW
Date
2024
Chk'd by
Date
App'd by
Date
WIND LOADING SINGLE MENU BOARD (PRE-SELL BOARD) (ASCE7-16)
WIND LOADING
In accordance with ASCE7-16
Using the directional design method
Tedds calculation version 2.1.13
Wall/sign data
Length of wall/sign B = 2.50 ft
Height of wall/sign s = 4.17 ft
Height to top of sign h = 6.00 ft
General wind load requirements
Basic wind speed V = 115.0 mph
Risk category II
Velocity pressure exponent coef (Table 26.6-1) Kd = 0.85
Ground elevation above sea level zgl = 0 ft
Ground elevation factor Ke = exp(-0.0000362 zgl/1ft) = 1.00
Exposure category (cl 26.7.3) C
Gust effect factor Gf = 0.85
Minimum design wind loading (cl.27.1.5) pmin_r = 8 lb/ft2
Topography
Topography factor not significant Kzt = 1.0
Velocity pressure
Velocity pressure coefficient (Table 26.10-1) Kz = 0.85
Velocity pressure qh = 0.00256 Kz Kzt Kd Ke V2 1psf/mph2 = 24.5 psf
Area of sign Af = B s = 10.425 ft2
Ratio of solid area to gross area = 1.00
Wall/sign forces – Case A and B
Force coefficient (Figure 29.3-1) Cf_A = 1.69
Resultant force FA = max(16psf, qh Gf Cf_A) Af = 0.4 kips
2303 S Bristol St
Unit A11/13/2024
Broyles And Associates
508 Baylor Court, Suite C
Chesapeake, Virgnia 23320
PH: 757-436-2070
Project
Starbucks
Job Ref.
Section
115 MPH Sign Foundation Design
Sheet no./rev.
2
Calc. by
RSW
Date
2024
Chk'd by
Date
App'd by
Date
Embedment calculation uses ASD loads = 0.6* Ult = 370# * 0.6 = 222#
2303 S Bristol St
Unit A11/13/2024
Project:Sign Designs Proj No:
Prepared By:RSW Date:8/7/24
Checked By: Sheet No:
Subject:
ASCE 7 Wind Loads Last updated:07/30/24
Directional Procedure
Square Footing Loading (at top of ftg)
Vol. of conc.:8.3 ft^3 V ULT=370 # (at center)
w conc=150 pcf V = 0.6 VULT=222 # (at center)115.8
f'c=3000 psi P =300 # (at center)156.5
fy=60000 psi M =888 ft-# (at center)463.3
e =0 in
Soil Sign Base Steel
k=90 pci Modulus of Subgrade reaction 12 ''x 14" baseplate
Soil angle:30 0.524 rad
Soil weight:110 pcf Footing W min = Pwall/ Qnet = 0.1ft
Q-net allow:1500 psf net allowable bearing Ftg width x length:1.917 2.167
Soil depth abv:0 in Ftg depth:24 in
Weight:0 plf Weight:650 plf
Cover to ties:3''As tie=0.028 in^2
Increase Soil Bearing Pressure?d=20.8125''0.028
Use soil wt?in Q-net 0 As min long= 1.123 in^2
Soil weight:0 # (per foot)
Use ftg wt?yes 1
Ftg weight:650 # (per foot)
P tot design=806.5 # (per foot)MRESIST = 1674.6ft-#MOT= 1331.9 ft-#
e=M/P tot=0.57 ft (outside kern)1' strip MRESIST = 873.7ft-# / ft MOT= 694.9 ft-#
e > b/6=0.36 :. Q=4/3*P/(L(B-2*e))
Qmax=1047 psf < 1800 psf gross +/-
Qmin=0 psf 1800
Assuming soil resulantant is located at "e"
Soil load width x=3(B/2-e)=18.48
Overturning and Sliding
Use soil wt?yes 1
Soil weight:0 # (per foot)
Use ftg wt?yes 1
Ftg weight:650 # (per foot)Footing Design Load factor=1.4
P tot Design=806.5 # (per foot)Bending:Lcr =7''from edge of ftg
1545.8 # total M pressure=156 ft-#
Slide frict=218 # friction Mu=1.4*Mp=218 ft-#
tan(o/2)=0.27 Shear:Lcr =0''from edge of ftg
Slide soil=0 # side soil V pressure=0 #
S Resist Total=218 # / ft length Vu=1.4*Vp=0 #
Slide FS =1.88 > 1.25
M resist=P tot*(width/2)=1674.6 ft-#Reinforced Footing Design:
=873.7 ft-# / ft ФMoment =0.9 ФShear =0.75
OT FS =1.26 > 1.25 Transverse ties:# 3 at 48'' oc
a=0.055 As tie=0.028 in^2
Unreinforced Footing Design:Ф =0.55 c=0.065 < 0.375*d=7.805
ФMn=Ф*5sqrt(f'c)(b*d^2/6)=10874 ft-# > 218ft-#ФMn=Ф*As*fy*(d-a/2)=2619 ft-# > 218ft-#
ФVn=Ф*4/3*sqrt(f'c)*b*h=11568 # > 0#ФVn=Ф*2*sqrt(f'c)*b*d=20519 # > 0#
0
2.167 ft x 1.917 ft x 24'' column footing is acceptable as an unreinforced footing.
Orig. size= 13''x 8''x 24''& New = 23''x 26''x 24''
| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| |
E| | E| | E| |E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E| | E
0
7
0
1047
650 1047
7''
0''
M
P
V
127
24
0
/ft
/ft
/ft
/ft
ft x ft
18.48
NWIND
9''9''
2303 S Bristol St
Unit A11/13/2024