Loading...
HomeMy WebLinkAbout2201 W Seventh St - PlanSHEET NUMBER CONSULTANT REVISIONS The above drawings, specifications, ideas, and arrangements represented thereby are and shall remain property of G Design and no part thereof shall be copied, disclosed to others or used in connection with any other project other than the specific project for which they have been prepared and developed, without the written consent of G Design. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and this office must be notified of any variations from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceding with fabrication. 2024 DATE SCALE DRAWN JOB no. GQ A-001 TI T L E S H E E T 7th STREET REMODEL 2201 W 7th STREET SANTA ANA, CA 92703 OCT 18, 2024 GIOVANNI QUINTERO 167 OAHU WAY PLACENTIA, CA 92870 TELEPHONE: 310 749.7536 E-MAIL: LOOKING4GIO@GMAIL.COM AUG 12, 2024 OCT 18, 2024 CORR #1 PROPERTY LINE 50' PROPERTY LINE 50' PR O P E R T Y L I N E 1 5 6 . 6 0 ' PR O P E R T Y L I N E 1 5 6 . 6 0 ' SINGLE FAMILY RESIDENCE W 7th STREET EXISTING DRIVEWAY EXISTING GRASS EX I S T I N G GR A S S EXISTING GRASS EXISTING CONCRETE 5-GALLON SHRUB 5-GALLON SHRUB 5-GALLON SHRUB 5-GALLON SHRUB 5-GALLON SHRUB 1-GALLON SHRUB 1-GALLON SHRUB 1-GALLON SHRUB 1-GALLON SHRUB 1-GALLON SHRUB 1-GALLON SHRUB 1-GALLON SHRUB 1-GALLON SHRUB 1-GALLON SHRUB 1-GALLON SHRUB 1-GALLON SHRUB 24" BOX CANOPY TREE (E ) S H R U B B NE I G H B O R ' S C H A I N L I N K F E N C E O F F S I T E PROJECT DIRECTORY OWNER: MONICA DEL CASTILLO 2201 W 7th STREET SANTA ANA, CA 92703 DESIGNER: GIOVANNI QUINTERO G DESIGN 167 OAHU WAY PLACENTIA, CA 92870 TEL: 310-749-7536 EMAIL: LOOKING4GIO@GMAIL.COM TITLE 24: EC SERVICES 5702 HERSHOLT AVE LAKEWOOD, CA 90712 TEL: 562-461-3749 SCOPE OF WORK (E) SINGLE FAMILY RESIDENCE -INTERIOR REMODEL -KITCHEN REMODEL -DEMO WALL BETWEEN KITCHEN AND LIVING ROOM -NEW POWDER ROOM -RELOCATE BEDROOM WINDOW CODE INFORMATION BUILDING CODES 2022 CALIFORNIA RESIDENTIAL BUILDING CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE SANTA ANA MUNICIPAL CODE CONSTRUCTION TYPE: TYPE VB OCCUPANCY TYPE: R3/U SPRINKLERS: NO PIN NUMBER: 123B149 198 LOT AREA: 7,830 sqft ASS PARCEL NO.: 007-352-11 FLOOR AREA RATIO EXISTING DWELLING (E) SQFT (N) SQFT TOTAL 1,011 1,011 1,011 NO SQUARE FOOTAGE ADDED VICINITY MAP SHEET INDEX TITLE SHEET / SITE PLAN ARCHITECTURAL A-001 TITLE 24A-002 A-100 PROPOSED LIGHTING AND ELECTRICALA-101 ELEVATIONSA-201 S0-0 PROPOSED FLOOR PLAN GENERAL STRUCTURAL NOTES STRUCTURAL S0-1 TYPICAL DETAILS S1-0 FOUNDATION PLAN AND FRAMING PLAN SD1 STRUCTURAL DETAILS N EXISTING SITE PLAN / PROPOSED LANDSCAPING SCALE 3/16" = 1'-0" CITY NOTES SPECIAL INSPECTION IS REQUIRED FOR EPOXY ANCHOR AND SHEAR WALL WITH NAILING AT 4" ON CENTER OR CLOSER BLDG# 101120873 APPROVALS BLDG - CSG Consultants PLNG - CSantana 2201 W Seventh St 12/9/2024 SHEET NUMBER CONSULTANT REVISIONS The above drawings, specifications, ideas, and arrangements represented thereby are and shall remain property of G Design and no part thereof shall be copied, disclosed to others or used in connection with any other project other than the specific project for which they have been prepared and developed, without the written consent of G Design. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and this office must be notified of any variations from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceding with fabrication. 2024 DATE SCALE DRAWN JOB no. GQ A-100 FL O O R P L A N S 7th STREET REMODEL 2201 W 7th STREET SANTA ANA, CA 92703 OCT 18, 2024 GIOVANNI QUINTERO 167 OAHU WAYPLACENTIA, CA 92870 TELEPHONE: 310 749.7536 E-MAIL: LOOKING4GIO@GMAIL.COM AUG 12, 2024 OCT 18, 2024 CORR #1 R 01 A 02 2'-0"4'-0"9'-0"3'-4 1/2" 3' - 2 " 3' - 1 " 2' - 0 " 1'-1/2" 2'-0"2'-9" 1'-7 1/2" 3'-0"2'-1/2"2'-0" 5'-1/2"6'-2 1/2"8'-5" 15"15" 2' - 3 " 2' - 5 " 1' - 1 0 " 1' - 9 " 6' - 6 " RELOCATE WINDOW DEMO WINDOW DEMO WINDOWDEMO WINDOW DEMO DOOR DEMO CABINETS DEMO WALL RELOCATE (E) WATER HEATER PATCH w/ STUCCO MATCH (E) PATCH w/ STUCCO MATCH (E) TYPICAL TACKLESS WH EXHAUST FAN 150.0(o) 1G OF 2022CENC LIVING ROOM KITCHEN CLOSET CLOSET CLOSET CLOSET BEDROOM BEDROOM BEDROOM BATHROOM LIVING ROOM KITCHEN CLOSET CLOSET CLOSET CLOSET BEDROOM BEDROOM BEDROOM BATHROOM GARAGE GARAGE RELOCATED WINDOW SD CM SD CM SD SD SD CLCL E N ID SIZE W X H DOOR TYPE 01 02 3'-0" x 6'-8" 2'-6" x 6'-8" AMOUNT 01 01INTERIOR 01 02 EXTERIOR ID SIZE W X H WINDOW TYPE 4'-0" x 3'-0" AMOUNT 01A A 3'-0" x 4'-0"01R R SLIDER CASEMENT U-FACTOR SHGC 0.3 0.3 0.28 0.28 N EXISTING FLOOR PLAN / DEMO SCALE 1/4" = 1'-0" SCHEDULES PROPOSED FLOOR PLAN SCALE 1/4" = 1'-0"N 2201 W Seventh St 12/9/2024 SHEET NUMBER CONSULTANT REVISIONS The above drawings, specifications, ideas, and arrangements represented thereby are and shall remain property of G Design and no part thereof shall be copied, disclosed to others or used in connection with any other project other than the specific project for which they have been prepared and developed, without the written consent of G Design. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and this office must be notified of any variations from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceding with fabrication. 2024 DATE SCALE DRAWN JOB no. GQ A-101 PR O P O S E D L I G H T I N G A N D E L E C 7th STREET REMODEL 2201 W 7th STREET SANTA ANA, CA 92703 OCT 18, 2024 GIOVANNI QUINTERO 167 OAHU WAYPLACENTIA, CA 92870 TELEPHONE: 310 749.7536 E-MAIL: LOOKING4GIO@GMAIL.COM AUG 12, 2024 OCT 18, 2024 CORR #1 LIVING ROOM KITCHEN CLOSET CLOSET CLOSET CLOSET BEDROOM BEDROOM FD LIVING ROOM KITCHEN CLOSET CLOSET CLOSET CLOSET BEDROOM BEDROOM +42 GFCI +42" +4 2 " G F C I +4 2 " PROPOSED ELEC PLAN SCALE 1/4" = 1'-0"N PROPOSED LIGHTING PLAN SCALE 1/4" = 1'-0"N 2201 W Seventh St 12/9/2024 SHEET NUMBER CONSULTANT REVISIONS The above drawings, specifications, ideas, and arrangements represented thereby are and shall remain property of G Design and no part thereof shall be copied, disclosed to others or used in connection with any other project other than the specific project for which they have been prepared and developed, without the written consent of G Design. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and this office must be notified of any variations from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceding with fabrication. 2024 DATE SCALE DRAWN JOB no. GQ A-201 EL E V A T I O N S 7th STREET REMODEL 2201 W 7th STREET SANTA ANA, CA 92703 OCT 18, 2024 GIOVANNI QUINTERO 167 OAHU WAYPLACENTIA, CA 92870 TELEPHONE: 310 749.7536 E-MAIL: LOOKING4GIO@GMAIL.COM AUG 12, 2024 OCT 18, 2024 CORR #1 WH TO BE ENCLOSED BY STUCCO FRAMED BOX SIDE ELEVATION - EAST SCALE 1/4" = 1'-0" REAR ELEVATION - NORTH SCALE 1/4" = 1'-0" 2201 W Seventh St 12/9/2024 STRUCTURAL STEEL REINFORCED CONCRETE WOOD CONCRETE MASONRY STRUCTURAL WOODGENERAL REQUIREMENTS 1.IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL GRADES, DIMENSIONS, ELEVATIONS AND CONDITIONS AT THE JOB SITE PRIOR TO BIDDING AND COMMENCING CONSTRUCTION. CROSS CHECK ALL DETAILS AND DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS WITH RELATED REQUIREMENTS ON THE ARCHITECTURAL, ELECTRICAL, MECHANICAL, AND CIVIL DRAWINGS AND NOTIFY THE ENGINEER AND THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING WORK. 2.EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE NOTED OR SHOWN IN THE PLANS OR SPECIFICATIONS, ALL PHASES OF WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE BUILDING CODE, LATEST ADDITION, AS WELL AS ALL APPLICABLE STATE AND LOCAL ORDINANCES AS ADOPTED BY THE CONTROLLING JURISDICTION. 3.THE CONTRACT DRAWINGS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE STRUCTURE SHOWN ON THESE DRAWINGS IS STRUCTURALLY SOUND ONLY IN THE COMPLETED FORM. GENERAL CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKMEN, AND OTHER PERSONS DURING CONSTRUCTION. SUCH MEASURES INCLUDE, BUT ARE NOT LIMITED TO; BRACING, SHORING FOR CONSTRUCTION EQUIPMENT,AND SHORING FOR THE STRUCTURE. 4.TIN NO CASE SHALL DIMENSIONS BE SCALED FROM DRAWINGS AND/OR DETAILS. ANY DISCREPANCIES FOUND WITHIN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER FOR CLARIFICATION PRIOR TO PROCEEDING. ANY WORK INSTALLED PRIOR TO AND/OR IN CONFLICT WITH SUCH CLARIFICATION SHALL BE CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER. 5.THE PRECISE DIMENSIONS AND LOCATIONS OF ALL DOOR AND WINDOW OPENINGS, INTERIOR AND EXTERIOR WALLS SHALL BE DETERMINED FROM THE ARCHITECTURAL DRAWINGS. OTHER FLOOR, WALL AND ROOF OPENINGS AS REQUIRED FOR MECHANICAL, ELECTRICAL AND/OR SIMILAR REQUIREMENTS SHALL BE VERIFIED FROM SHOP DRAWINGS, EQUIPMENT DATA, ETC. AS REQUIRED. 6.FLOOR AND WALL OPENINGS, SLEEVES, VARIATIONS IN STRUCTURAL SLAB ELEVATIONS, DEPRESSED AREAS, AND ALL OTHER ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND/OR CIVIL REQUIREMENTS MUST BE COORDINATED BEFORE THE CONTRACTOR PROCEEDS WITH CONSTRUCTION. 7.THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION AND COORDINATION WITH ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER DRAWINGS,AND ALL OTHER RELATED DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR THE AND ALL OTHER RELATED DRAWINGS. 8.IN ALL CASES WHERE A CONFLICT MAY OCCUR SUCH AS BETWEEN ITEMS INCLUDED IN THE SPECIFICATIONS AND NOTES ON THE DRAWINGS, OR BETWEEN GENERAL NOTES AND SPECIFIC DETAILS, THE ENGINEER SHALL BE NOTIFIED AND HE WILL INTERPRET THE INTENT OF THE CONTRACT DOCUMENTS. 9.ALL MATERIALS SHALL BE FURNISHED AS SHOWN HEREIN UNLESS ALTERNATES ARE APPROVED IN WRITING BY THE ARCHITECT, OWNER AND STRUCTURAL ENGINEER OF RECORD. 10.ANY REFERENCE TO THE WORDS APPROVED OR APPROVAL IN THESE DOCUMENTS SHALL BE DEFINED TO MEAN GENERAL ACCEPTANCE OR REVIEW AND SHALL NOT RELIEVE THE CONTRACTOR AND/OR HIS SUBCONTRACTORS OF ANY LIABILITY IN FURNISHING THE REQUIRED MATERIALS OR LABOR SPECIFICATION. 11.WHERE A DETAIL, SECTION OR NOTE IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL LIKE OR SIMILAR CONDITIONS UNLESS NOTED OTHERWISE. DETAILS MARKED "TYPICAL" SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. WHERE NO SPECIFIC DETAIL IS SHOWN, THE FRAMING OR CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO LIKE CASES OF CONSTRUCTION. 12.CONNECTIONS OF ALL ITEMS SUPPORTED BY THE STRUCTURE ARE THE RESPONSIBILITY OF THE DISCIPLINES WHO MAKE THESE ATTACHMENTS. REVIEW AND COORDINATE ALL THE REQUIREMENTS IN THE ARCHITECTS PROJECT SPECIFICATION AS APPLICABLE. 13.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, WHETHER INDICATED ON THE CONTRACT DRAWING OR NOT, AND TO PROTECT THEM FROM DAMAGE. REPAIR AND REPLACEMENT OF SAID WORK SHALL BE AT THE EXPENSE OF THE CONTRACTOR. 14.VIBRATIONAL EFFECTS OF MECHANICAL AND/OR ANY OTHER EQUIPMENT HAVE NOT BEEN CONSIDERED BY THE STRUCTURAL ENGINEER. 15.UNLESS NOTED OTHERWISE, ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE TO THE TOP OF BEAMS AND FOUNDATIONS. BEAMS DENOTED AS "DROP" HAVE THE TOP OF BEAM AT THE HEIGHT OF THE TOP PLATE. BEAMS DENOTED AS "FLUSH" HAVE THE BOTTOM OF BEAM AT THE HEIGHT OF THE TOP PLATE, U.N.O. 5.LUMBER GRADES ( U.N.O. ) 6X & 8X POSTS/BEAMS/HEADERS: #1 DFL 4X POSTS/BEAMS/HEADERS: #2 DFL 2X JOISTS/RAFTERS: #2 DFL STUDS: D.F.L. STUD GRADE (UP TO 9'-0"), D.F.L. #2 (HIGHER THAN 9'-0") TOP PLATES & MUD SILLS: D.F.L. CONSTRUCTION GRADE,#2, OR BETTER. 6.TYPICAL FLOOR SHEATHING 23/32" APA RATED STURD-I-FLOOR T&G EXP I (OR OSB) WITH MIN. SPAN RATING OF 24" O.C. REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE B.N.:10D COMMON NAILS AT 6" O.C. E.N.:10D COMMON NAILS AT 6" O.C. F.N.:10D COMMON NAILS AT 12" O.C. USE RING OR SCREW SHANK NAILS AND GLUE SHEATHING TO FRAMING USING ADHESIVES MEETING APA SPECIFICATION AFG-01 OR ASTM D3498. APPLY GLUE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. AS AN ALTERNATE TO 10D COMMON NAILS, THE FOLLOWING FASTNERS CAN BE USED: GRABBER PLYWOOD SCREWS (ICC-ER-5280), OR SIMPSON STRONG-TIE QUICK DRIVE SCREWS (ICC-ER-1472), MIN 2" LONG @ 6" O.C. B.S., @ 6" O.C. E.S. AND 12" O.C. F.S. 7.TYPICAL ROOF SHEATHING DOC PS1 OR DOC PS2. 15/32" APA RATED SHEATHING EXP 1 (OR OSB) WITH A MIN. PANEL INDEX OF 32/16. REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE. B.N.:8D COMMON NAIL AT 6" O.C. E.N.:8D COMMON NAIL AT 6" O.C. F.N.:8D COMMON NAIL AT 12" O.C. NOTE*: ALL STRUCTURAL RATED PANELS MUST BE STAMPED BY ONE OF THE FOLLOWING APPROVED AGENCIES, APA, PFS/TECO OR PITTSBURG. SHEAR WALL NOTES: 1.FRAMING AT ADJOINING PANEL EDGES SHALL BE 3 INCHES NOMINAL OR WIDER, AND NAILS SHALL BE STAGGERED WHERE NAILS ARE SPACED 2 INCHES ON CENTER. 2.WHERE SHEAR DESIGN VALUES EXCEED 350 PLF., ALL FRAMING MEMBERS RECEIVING EDGE NAILING FROM ABUTTING PANELS SHALL NOT BE LESS THAN A SINGLE 3-INCH NOMINAL MEMBER, OR TWO 2-INCH NOMINAL MEMBERS FASTENED TOGETHER IN ACCORDANCE WITH SECTION 2306.1 TO TRANSFER THE DESIGN SHEAR VALUE BETWEEN FRAMING MEMBERS. WOOD STRUCTURAL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED IN ALL CASES. SEE SECTION 2305.3.11 FOR SILL PLATE SIZE AND ANCHORAGE REQUIREMENTS. NAILS SHALL BE PLACED NOT LESS THAN 1/2" EDGE DISTANCE FROM THE PANEL EDGES AND 3/8" FROM THE EDGE OF THE CONNECTING MEMBERS. 3.ANCHOR BOLTS FOR SHEAR WALLS SHALL INCLUDE STEEL PLATE WASHERS, A MINIMUM OF 0.229 INCHES BY 3 INCHES BY 3 INCHES IN SIZE, BETWEEN THE SILL PLATE AND NUT. ANCHOR BOLTS: 1.MINIMUM 5/8"Ø STEEL BOLTS EMBEDDED 7" @ 48" O.C. INTO THE FOUNDATION WITH MINIMUM 3" S.Q x 0.25" PLATE WASHER FOR THE ANCHOR BOLTS. MINIMUM EDGE DISTANCE 1-7/8" AND WITHIN 12" OF EACH END OF EACH PLATE. 2.ALL SHEAR HARDWARE AND ANCHOR BOLTS W/ NON-STANDARD SPACING ARE TO BE FIXED IN PLACE FOR THE FOUNDATION INSPECTION. 3.FASTENERS FOR PRESERVATIVE-TREATED SHALL BE NOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. 4.A PROPERLY SIZED NUT AND WASHER SHALL BE TIGHTENED ON EACH ANCHOR BOLT TO THE PLATE. 5.HOLDOWN CONNECTORS BOLTS HOLES SHALL NOT BE MORE THAN 1/16" OVERSIZED AT THE CONNECTOR OF THE HOLD DOWN TO THE POST. 6.HOLD DOWN CONNECTORS SHALL BE RE-TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. 7.ALL FOUNDATIONS SHALL BEAR UPON LIKE MATERIAL. 8.FINAL SOILS / AS-GRADED REPORT WILL BE REQUIRED AT FOUNDATION / SLAB INSPECTION. NAILING SCHEDULE: (TABLE R602.3(1) W/ FOOT NOTES 2022 CRC) ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENERa, b, c SPACING AND LOCATION 1 Blocking between ceiling joists or rafters to top plate 4-8d box (2 1/2″ × 0.113″) or 3-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails Toe nail 2 Ceiling joists to top plate 4-8d box (2 1/2″ × 0.113″); or 3-8d common 2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails Per joist, toe nail 3 Ceiling joist not attached to parallel rafter, laps over partitions [see Sections R802.3.1, R802.3.2 and Table R802.5.1(9)] 4-10d box (3″ × 0.128″); or 3-16d common (3 1/2″ × 0.162″); or 4-3″ × 0.131″ nails Face nail 4 Ceiling joist attached to parallel rafter (heel joint) [see Sections R802.3.1 and R802.3.2 and Table R802.5.1(9)] Table R802.5.1(9)Face nail 5 Collar tie to rafter, face nail or 11/4″ × 20 ga. ridge strap to rafter 4-10d box (3″ × 0.128″); or 3-10d common (3″ × 0.148″); or 4-3″ × 0.131″ nails Face nail each rafter 6 Rafter or roof truss to plate 3-16d box nails (3 1/2″ × 0.135″); or 3-10d common nails (3″ × 0.148″); or 4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails 2 toe nails on one side and 1 toe nail on opposite side of each rafter or truss 7 Roof rafters to ridge, valley or hip rafters or roof rafter to minimum 2″ ridge beam 4-16d (3 1/2″ × 0.135″); or 3-10d common (3 1/2″ × 0.148″); or 4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails Toe nail 3-16d box 3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails End nail WALL 8 Stud to stud (not at braced wall panels) 16d common (3 1/2″ × 0.162″)24″ o.c. face nail 10d box (3″ × 0.128″); or 3″ × 0.131″ nails 16″ o.c. face nail 9 Stud to stud and abutting studs at intersecting wall corners (at braced wall panels) 4-10d box (3″ × 0.128″); or 3-16d common (3 1/2″ × 0.162″); or 4-3″ × 0.131″ nails 12″ o.c. face nail 16d common (3 1/2″ × 0.162″)16″ o.c. face nail 10 Built-up header (2″ to 2″ header with 1/2″ spacer) 16d common (3 1/2″ × 0.162″)16″ o.c. each edge face nail 16d box (3 1/2″ × 0.135″)12″ o.c. each edge face nail 11 Continuous header to stud 5-8d box (2 1/2″ × 0.113″); or 4-8d common (2 1/2″ × 0.131″); or 4-10d box (3″ × 0.128″) Toe nail 12 Top plate to top plate 16d common (3 1/2″ × 0.162″)16″ o.c. face nail 10d box (3″ × 0.128″); or 3″ × 0.131″ nails 12″ o.c. face nail 13 Double top plate splice for SDCs A-D2 with seismic braced wall line spacing < 25' 8-16d common (3 1/2″ × 0.162″); or 12-16d box (3 1/2″ × 0.135″); or 12-10d box (3″ × 0.128″); or 12-3″ × 0.131″ nails Face nail on each side of end joint (minimum 24″ lap splice length each side of end joint)Double top plate splice SDCs D0, D1, or D2; and braced wall line spacing ≥ 25' 12-16d (3 1/2″ × 0.135″) 14 Bottom plate to joist, rim joist, band joist or blocking (not at braced wall panels) 16d common (3 1/2″ × 0.162″)16″ o.c. face nail 16d box (3 1/2″ × 0.135″); or 3″ × 0.131″ nails 12″ o.c. face nail 15 Bottom plate to joist, rim joist, band joist or blocking (at braced wall panel) 3-16d box (3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″); or 4-3″ × 0.131″ nails 3 each 16″ o.c. face nail 2 each 16″ o.c. face nail 4 each 16″ o.c. face nail 16 Top or bottom plate to stud 4-8d box (2 1/2″ × 0.113″); or 3-16d box (3 1/2″ × 0.135″); or 4-8d common (2 1/2″ × 0.131″); or 4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails Toe nail 3-16d box (3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails End nail 17 Top plates, laps at corners and intersections 3-10d box (3″ × 0.128″); or 2-16d common (3 1/2″ × 0.162″); or 3-3″ × 0.131″ nails Face nail 18 1″ brace to each stud and plate 3-8d box (2 1/2″ × 0.113″); or 2-8d common (2 1/2″ × 0.131″); or 2-10d box (3″ × 0.128″); or 2 staples 1 3/4″ Face nail 19 1″ × 6″ sheathing to each bearing 3-8d box (2 1/2″ × 0.113″); or 2-8d common (2 1/2″ × 0.131″); or 2-10d box (3″ × 0.128″); or 2 staples, 1″ crown, 16 ga., 1 3/4″ long Face nail 20 1″ × 8″ and wider sheathing to each bearing 3-8d box (2 1/2″ × 0.113″); or 3-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 3 staples, 1″ crown, 16 ga., 1 3/4″ long Face nailWider than 1″ × 8″ 4-8d box (2 1/2″ × 0.113″); 3-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 4 staples, 1″ crown, 16 ga., 1 3/4″ long FLOOR 21 Joist to sill, top plate or girder 4-8d box (2 1/2″ × 0.113″); or 3-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails Toe nail 22 Rim joist, band joist or blocking to sill or top plate (roof applications also) 8d box (2 1/2″ × 0.113″)4″ o.c. toe nail 8d common (2 1/2″ × 0.131″); or 10d box (3″ × 0.128″); or 3″ × 0.131″ nails 6″ o.c. toe nail 23 1″ × 6″ subfloor or less to each joist 3-8d box (2 1/2″ × 0.113″); or 2-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 2 staples, 1″ crown, 16 ga., 1 3/4″ long Face nail 24 2″ subfloor to joist or girder 3-16d box (3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″)Blind and face nail 25 2″ planks (plank & beam—floor & roof) 3-16d box (3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″) At each bearing, face nail 26 Band or rim joist to joist 3-16d common (3 1/2″ × 0.162″) 4-10 box (3″ × 0.128″), or 4-3″ × 0.131″ nails; or 4-3″ × 14 ga. staples, 7/16″ crown End nail 27 Built-up girders and beams, 2-inch lumber layers 20d common (4″ × 0.192″) Nail each layer as follows: 32″ o.c. at top and bottom and staggered. 10d box (3″ × 0.128″); or 3″ × 0.131″ nails 24″ o.c. face nail at top and bottom staggered on opposite sides And: 2-20d common (4″ × 0.192″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails Face nail at ends and at each splice 28 Ledger strip supporting joists or rafters 4-16d box (3 1/2″ × 0.135″); or 3-16d common (3 1/2″ × 0.162″); or 4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails At each joist or rafter, face nail 29 Bridging to joist 2-10d (3″ × 0.128″)Each end, toe nail ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER a, b, c SPACING OF FASTENERS Edges (inches)h Intermediat e supports c, e (inches) Wood structural panels, subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing to framing [see Table R602.3(3) for wood structural panel exterior wall sheathing to wall framing] 30 3/8″ – 1/2″ 6d common (2″ × 0.113″) nail (subfloor, wall) 8d common (21/2″ × 0.131″) nail (roof) 6 12f 31 19/32″ – 1″8d common nail (21/2″ × 0.131″)6 12f 32 11/8″ – 11/4″10d common (3″ × 0.148″) nail; or 8d (21/2″ × 0.131″) deformed nail 6 12 Other wall sheathing 33 1/2″ structural cellulosic fiberboard sheathing 1 1/2″ galvanized roofing nail, 7/16″ head diameter, or 1″ crown staple 16 ga., 1 1/4″ long 3 6 34 25/32″ structural cellulosic fiberboard sheathing 1 3/4″ galvanized roofing nail, 7/16″ head diameter, or 1″ crown staple 16 ga., 1 1/4″ long 3 6 35 1/2″ gypsum sheathingd 1 1/2″ galvanized roofing nail; staple galvanized, 1 1/2″ long; 1 1/4″ screws, Type W or S 7 7 36 5/8″ gypsum sheathingd 1 3/4″ galvanized roofing nail; staple galvanized, 1 5/8″ long; 1 5/8″ screws, Type W or S 7 7 Wood structural panels, combination subfloor underlayment to framing 37 3/4″ and less 6d deformed (2″ × 0.120″) nail; or 8d common (2 1/2″ × 0.131″) nail 6 12 38 7/8″ – 1″8d common (2 1/2″ × 0.131″) nail; or 8d deformed (2 1/2″ × 0.120″) nail 6 12 39 1 1/8″ – 1 1/4″10d common (3″ × 0.148″) nail; or 8d deformed (2 1/2″ × 0.120″) nail 6 12 1.REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE WITH ACI 315 AND ACI 318, AND CRSI'S MANUAL OF STANDARD PRACTICE. 2.REINFORCING STEEL SHALL CONFORM TO ASTM A615OR ASTM 716(WELDABLE STEEL) AND SHALL BE GRADE 60 DEFORMED BARS, TYP., U.N.O. REINFORCING IN SLAB ON GRADE MAYBE GRADE 40 STEEL FOR BARS #4 AND SMALLER U.N.O ON THE PLANS. 3.WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. LAPS IN WWF SHALL BE SUCH THAT THE OVERLAP MEASURED BETWEEN OUTERMOST CROSS WIRE OF EACH FABRICH SEET IS NOT LESS THAN THE SPACING OF CROSS WIRES PLUS 2 INCHES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING BARS/STEEL ARE TO THE CENTER OF STEEL U.N.O. ON THE PLANS OR DETAILS: CONDITION COVER A. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" B. EXPOSED TO EARTH OR WEATHER (INCLUDING SLABS ON GRADE) #6 AND LARGER 2" #5 AND SMALLER 1 1/2" C. NOT EXPOSED TO WEATHER OR IN CONTACT WITH SOIL: 1. STRUCTURAL SLABS, WALLS w/ #11 BARS AND SMALLER 3/4" #14 BARS AND LARGER 1 1/2" 2. BEAMS, COLUMNS 1 1/2" 5.LAP SPLICES OF BARS SHALL CONFORM TO THE TYPICAL THE LAP SCHEDULE ON THE PLANS, U.N.O. NO TACK WELDING OF BARS ALLOWED 6.MECHANICAL SPLICE COUPLERS MAY BE USED AND SHALL HAVE CURRENT ICC APPROVAL AND BE CAPABLE OF DEVELOPING 125% OF THE BAR'S YIELD STRENGTH. 7.ALL REINFORCING BARS SHALL BE BENT COLD. DO NOT FIELD BEND OR UNBEND ANY BARS IN A MANNER THAT MAY DAMAGE REINFORCING. 8.REINFORCING SPACING SHOWN ON THE PLANS ARE THE MAXIMUM SPACING "ON CENTER SPACING". DO NOT EXCEED THIS. ANY DISCREPANCIES DURING CONSTRUCTION SHALL BE FORWARDED TO THE ENGINEER FOR REVIEW AND APPROVAL. 9.TYPICAL REINFORCING FOR CONCRETE SLAB ON METAL DECK SHALL BE 6x6-W1.4xW1.4 WELDED WIRE FABRIC, U.N.O. PLACE WWF MID-DEPTH OF THE SLAB OVER THE TOP OF THE FLUTE OF THE METAL DECK. 10.ALL DOWELS TO BE SET IN CONCRETE SHALL BE TIED IN PLACE PRIOR TO PLACEMENT OF CONCRETE. NO WET SETTING, STABBING, RODDING OR OTHER MOVEMENT OF EMBEDDED ITEMS SHALL BE PERFORMED DURING THE PLACEMENT OF CONCRETE. 11.DOWELS BETWEEN FOOTING AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE AND SPACING AS THE MAIN REINFORCING, UNO. 12.CHAIRS OR SPACERS FOR REINFORCING SHALL BE NON-FERROUS OR PLASTIC COATED WHEN RESTING ON EXPOSED SURFACES. 1.CONCRETE SHALL BE SUPPLIED AND PLACED IN ACCORDANCE WITH THE LATEST EDITION OF ACI 318 AND ACI 301 EXCEPT AS MODIFIED BY THE CONSTRUCTION DOCUMENTS. 2.PORLAND CEMENT SHALL CONFORM TO ASTM C-150, TYPE II, U.N.O. 3.AGGREGATE FOR STONE CONCRETE SHALL CONFORM TO ASTM C-33. FOR LOWSHRINKAGE AGGREGATE, USE LIMESTONE OR GRANITE. AGGREGATE FORLIGHTWEIGHTCONCRETE SHALL CONFORM TO ASTM C-330 4.DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER USED IN MIXING CONCRETE SHALL CONFORM WITH ASTM C1602. 5.CONCRETE MIX DESIGNS CONTAINING FLY ASH MAY BE USED WHERE CONCRETE IS NOT VISUALLY EXPOSED. FLY ASH SHALL CONFORM WITH ASTM C618 AND MAY REPLACE UP TO 20% PORTLAND CEMENT BY VOLUME. 6.CONCRETE STRENGTH TEST REPORTS SHALL BE IN COMPLIANCE WITH ACI 318 AND SHALL BE SUBMITTED TO E.O.R. FOR REVIEW. 7.ALL REINFORCING BARS, ANCHOR BOLTS AND ALL OTHER CONCRETE INSERTS SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE. 8.THE CONCRETE COMPRESSIVE STRENGTH (28 DAYS), f'c: a. ALL LOCATIONS, U.N.O: MIN 2500 PSI, (W/C = 0.45) SPECIAL INSPECTION IS REQUIRED WHEN f'c > 2500 PSI. b. CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE So4 ≥ 0.1% BY WEIGHT: 4000 PSI, SPECIAL INSPECTION IS NOT REQUIRED. c. CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE So4 ≥ 0.2% BY WEIGHT: 4500 PSI, SPECIAL INSPECTION IS NOT REQUIRED. 9.TIME BETWEEN CONCRETE BATCHING AND PLACEMENT SHALL BE IN ACCORDANCE WITH ASTM C94. 10.CONCRETE PLACEMENT/CURING/REDUCTION IN STRENGTH SHALL CONFORM TO ACI 305R AND 3065R REQUIREMENTS FOR HOT AND COLD WEATHER CONCRETING. 11.CONCRETE SHALL BE CURED PER ACI 308R, UNLESS ALTERNATE METHODS OF CURING HAVE BEEN APPROVED BY THE ARCHITECT OR ENGINEER. FOR SLAB CURING, CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING COMPATIBILITY OF CURING COMPOUNDS WITH PROPOSED FINISHES PRIOR TO COMMENCING ANY WORK. 12.MAX. SLUMP SHALL BE 5 INCHES EXCEPT WHERE ADMIXTURES/PLACITIZERS HAVE BEEN ADDED IN THE MIX DESIGN TO IMPROVE FLOW ABILITY/WORKABILITY. THE SLUMP LIMIT SHALL BE BASED ON ADMIXTURE MANUFACTURER'S RECOMMENDATIONS. 1.ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR LARCH CONFORMING TO WEST COAST LUMBER INSPECTION BUREAU GRADING RULES #17. MOISTURE CONTENT NOT TO EXCEED 19% AT TIME OF CONSTRUCTION. 2.WOOD-BASED STRUCTURAL USE PANELS SHALL MEET THE REQUIREMENTS OF DOC PS 2-10. STRUCTURAL SHEATHING MAY BE EITHER OSB OR PLYWOOD. 3.STRUCTURAL COMPOSITE LUMBER (SCL) SHALL CONFORM TO THE MANUFACTURER'S ICC REPORT IN COMPLIANCE WITH THE GOVERNING BUILDING CODE FOR THE PROJECT LISTED. 4.ENGINEERED GLU-LAM BEAMS SHALL BE INSPECTED AND AN A.I.T.C. CERTIFICATE OF COMPLIANCE SHALL BE PROVIDED TO THE INSPECTOR PRIOR TO INSTALLATION. ALL GLU-LAM BEAMS SHALL BE FABRICATED WITH WATERPROOF GLUE WITH STANDARD CAMBER U.N.O. 5.GLU-LAM BEAMS MAY NOT BE SUBSTITUTED FOR STRUCTURAL COMPOSITE LUMBER (SCL) BEAMS UNLESS WRITTEN AUTHORIZATION IS PROVIDED BY THE ENGINEER OF RECORD. 6.ALL WOOD FRAMING MEMBERS DIRECTLY AGAINST CONCRETE OR MASONRY INSTALLED IN A DRY OR ENCLOSED ENVIRONMENT SHALL BE PRESSURE TREATED DOUG-FIR TREATED WITH SODIUM BORATE (SBX/DOT). CORROSION RESISTANT CONNECTORS ARE NOT REQUIRED WITH SODIUM BORATE TREATED LUMBER. IF OTHER TREATMENTS ARE USED, GALVANIZED FASTENERS PER "FASTENER REQUIREMENTS" NOTE 3 ARE REQUIRED. 7.LUMBER GRADE STAMPS ARE TO REMAIN IN PLACE AFTER INSTALLATION WHERE POSSIBLE. 8.LUMBER GRADES ARE TO BE AS FOLLOWS: STUDS UP TO 10'-0"..............................................................................................STUD GRADE STUDS OVER 10'-0".............................................................................................................DF #2 BLOCKING............................................................................................STANDARD OR BETTER PLATES & SILL.....................................................................................STANDARD OR BETTER TOP PLATES........................................................................................................................DF #2 4X4 BEAMS/POSTS.............................................................................STANDARD OR BETTER 4X6 THROUGH 4X12BEAMS/POSTS.................................................................................DF #2 4X14BEAMS/POSTS.............................................................................................................DF#1 6X & LARGER BEAMS/POSTS............................................................................................DF #1 2X RAFTER/JOIST...............................................................................................................DF #2 9.UTILITY GRADE LUMBER IS UNACCEPTABLE FOR ANY PURPOSE. 10.THE FOLLOWING BEAMS/HEADERS/RIMS CAN BE FROM ANY MANUFACTURER WITH CURRENT APPROVED ICC ES - EVALUATION REPORT WITH THE FOLLOWING MECHANICAL PROPERTIES: FOR "LVL" & "PSL" BEAMS: Fb = 2900 psi (MIN), Fv = 290 psi (MIN), E = 2.0 x 106 psi (MIN). FOR "LSL" BEAMS/HEADERS: Fb = 2325 psi (MIN), Fv = 400 psi (MIN), E = 1.55 x 106 psi (MIN). FOR MANUFACTURED RIM BOARD WITH MIN 1 1/4" THICK, CONTINUOUSLY SUPPORTED BY WALL , AND MATCHES JOIST DEPTH: Fc I (PERPENDICULAR)........ = 680 psi (MIN) Fc // (PARALLEL)..................... = 1400 psi (MIN) Ft = 1075 psi (MIN), E = 1.3 x 106 psi (MIN) GLU-LAM BEAM SHALL BE 24F-V4, DF/DF Fb = 2400 psi @ BOTTOM, Fb = 1850 psi @ TOP Fv = 265 psi (MIN), E = 1.8 x 106 psi (MIN). 11.ROOF SHEATHING SHALL BE 15/32" APA RATED SHEATHING EXP 1 WITH A SPAN RATING OF 24/0 WITH 8D NAILS AT 6" O/C AT EDGES AND BOUNDARIES AND 12" O/C FIELD NAILING. 12.FLOOR SHEATHING SHALL BE 23/32" APA RATED SHEATHING EXP 1 WITH A MINIMUM SPAN RATING OF 48/24 WITH 10D NAILS AT 6" O/C AT EDGES AND BOUNDARIES AND 10" O/C FIELD NAILING. FOUNDATION 1.THE FOUNDATION DESIGN IS BASED UPON CHAPTER 4 C.R.C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIREMENTS THEREIN AND MAINTAIN A COPY ON THE JOB SITE AT ALL TIMES. 2.THE ENGINEER OF RECORD MUST BE INFORMED OF ANY CHANGES IN DESIGN CRITERIA MADE BY ANY SOILS GEOLOGIST IN THE COURSE OF CONSTRUCTION. 3.ALL FOOTINGS AND SLABS SHALL BE FOUNDED ON FIRM UNDISTURBED NATURAL SOILS OR APPROVED COMPACTED FILL. CONTRACTOR TO PROVIDE BUILDING INSPECTOR WITH COMPACTION REPORTS AND/OR WRITTEN APPROVAL OF COMPACTED FILL FROM A SOIL GEOLOGIST FOR ANY REQUIRED FILL. 4.ALL COMPACTED FILL SHALL BE PLACED IN AN APPROVED MANNER WITH A MINIMUM DENSITY OF 90% OF THE MAXIMUM OBTAINABLE IN ACCORDANCE WITH ASTM D 1557. 5.ALL FOUNDATION EXCAVATIONS, FILLING, BACK FILLING, AND BUILDING PADS SHALL BE INSPECTED AND APPROVED BY THE CITY BUILDING INSPECTOR BOTH PRIOR TO, AND AFTER PLACEMENT OF REINFORCEMENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SHORING NECESSARY TO SUPPORT CUT AND/OR FILL SECTIONS DURING EXCAVATION AND FOR FORMING AND PLACEMENT OF CONCRETE. 6.THE CONTRACTOR SHALL INFORM THE ARCHITECT AND ENGINEER OF THE LOCATION OF EXISTING UTILITIES AND COMMENCE WORK ONLY AFTER WRITTEN APPROVAL FROM THE ARCHITECT. 7.ALL RETAINING WALLS HAVE BEEN DESIGNED AS A FREE DRAINING CONDITION. DESIGN FOR THE DRAINAGE SYSTEM SHALL BE BY OTHERS AND SHALL MEET THE REQUIREMENTS OF THE SOILS REPORT.BACK FILL AGAINST WALLS SHALL BE PLACED EVENLY AGAINST BOTH SIDES OF WALLS UNTIL THE LOWER GRADE IS REACHED. 8.FOOTING WITH MINIMUM REINFORCEMENT OF: 2#4 @ TOP & 2#4 @ BOTTOM. OR U.N.O 9.EXISTING FOOTING : USE EPOXY FOR A.B. WITH SAME LENGTH AS REGULAR BOLTS WITH SPECIAL INSPECTION. GENERAL 1.ALL CONCRETE MASONRY MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH BUILDING CODE, CHAPTER 21. MATERIALS 2.ALL MATERIALS MAKING UP FINISHED CONCRETE MASONRY CONSTRUCTION SHALL CONFORM TO STANDARDS REQUIRED BY BUILDING CODE SEC. 2103. 3.MORTAR SHALL BE TYPE M OR S AS APPLICABLE AND CONFORMING WITH ASTM C270 AND SHALL BE PROPORTIONED PER ARTICLE 2.1 & 2.6A OF SPECIFICATION FOR MASONRY STRUCTURES (TMS 602-16). 4.GROUT SHALL COMPLY WITH ARTICLE 2.2 OF TMS 602-16 AND SHALL ATTAIN A MINIMUM COMPRESSION STRENGTH AT 28 DAYS OF 1500 PSI OR THE REQUIRED COMPRESSION, F'M, WHICHEVER IS GREATER. THE COMPRESSIVE STRENGTH OF GROUT SHALL BE DETERMINED IN ACCORDANCE WITH ASTM C-1019. 5.CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 FOR LOAD BEARING CONCRETE MASONRY UNITS. CONCRETE BRICK SHALL CONFORM TO ASTM C55, SPECIFICATIONS FOR CONCRETE BUILDING BRICK. 6.GRADE N CONCRETE BRICKS ARE FOR USE AS ARCHITECTURAL VENEER AND FACING, LIMITED TO IN EXTERIOR WALLS. 7.GRADE S CONCRETE BRICKS ARE FOR GENERAL USE WHERE MODERATE STRENGTH AND RESISTANCE TO FROST ACTION AND MOISTURE PENETRATION IS REQUIRED. STRENGTH 8.THE SPECIFIED COMPRESSIVE STRENGTH OF MASONRY, F'M, SHALL BE 2000 PSI, UNLESS NOTED OTHERWISE. IF HIGHER F'M IS NOTED, IT SHALL BE VERIFIED BY PRISM TESTS AS REQUIRED IN ARTICLE 1.4 SPECIFICATION OF MASONRY STRUCTURES (TMS 602-16). 9.REINFORCING STEEL SHALL CONFORM TO ASTM A615. GRADE 40 FOR SIZES #3 AND GRADE 60 FOR SIZES #4 AND LARGER. SPECIAL INSPECTION 10.SPECIAL INSPECTION FOR CONCRETE MASONRY CONSTRUCTION SHALL BE CARRIED OUT IN ACCORDANCE WITH BUILDING CODE SECTION 1704 AND REQUIREMENTS IN SPECIAL INSPECTION TABLES ON SHEET SN-1. MASONRY COMPRESSIVE STRENGTH, F'M SHALL BE VERIFIED BY UNIT STRENGTH METHOD OR PRISM TEST METHOD PRIOR TO AND DURING CONSTRUCTION AS DESCRIBED IN ARTICLE 1.4 SPECIFICATION FOR MASONRY STRUCTURES (TMS 602-16). 1.SOILS SOILS ALLOWABLE DESIGN VALUES IS 1500 PSF, 2.BUILDING CODE - 2022 CALIFORNIA BUILDING CODE 3.DESIGN LOADS: 4.LATERAL LOADS: ROOF LOAD DEAD LOAD = 16 PSF LIVE LOAD = 20 PSF TOTAL = 36 PSF RISK CATEGORY: II SEISMIC DESIGN CATEGORY: D SEISMIC IMPORTANCE FACTOR (I) = 1.0 SITE CLASS = D-Default WIND SPEED:110 MPH WIND EXPOSURE:C Ss:1.306 S1:0.465 Csy:0.113 Ry:6.5 Csx:0.113 RX: 6.5 DESIGN CRITERIA SILL PLATE NAILING (16D SINKER) SHEAR WALL SCHEDULE: TYPE SHEAR PANEL 1 260 PLF 3/8" APA STRUCT. RATED PLYWOOD(or OSB) WITH 8d COMMON NAILS AT 6" O.C. EDGES AND 12" O.C. FIELD 2 380 PLF 3 490 PLF 4 640 PLF 3/8" APA STRUCT. RATED PLYWOOD(or OSB) WITH 8d COMMON NAILS AT 4" O.C. EDGES AND 12" O.C. FIELD 3/8" APA STRUCT. RATED PLYWOOD(or OSB) WITH 8d COMMON NAILS AT 3" O.C. EDGES AND 12" O.C. FIELD 3/8" APA STRUCT. RATED PLYWOOD(or OSB) WITH 8d COMMON NAILS AT 2" O.C. EDGES AND 12" O.C. FIELD 5 800 PLF 15/32" APA STRUCT I. RATED PLYWOOD WITH 10d COMMON NAILS AT 2" O.C. EDGES AND 12" O.C. FIELD 6" O.C., OR A35 @ 24" O.C. 4" O.C., OR A35 @ 16" O.C. 3" O.C., OR A35 @ 12" O.C. 2" O.C., OR A35 @ 10" O.C. (2)3" O.C., OR A35 @ 6" O.C. FRAMING CLIP A35's,LS50's OR LTP4's. 16" O.C. 12" O.C. 8" O.C. 6" O.C. 5" O.C. SHEET INDEX No.SHEET NO.SHEET NAME 1 S0.0 - GENERAL STRUCTURAL NOTES. 2 S0.1 - TYPICAL DETAILS. 3 S1.0 - FOUNDATION PLAN & FRAMING PLAN. 4 SD1 - STRUCTURAL DETAILS. BASIC SEISMIC FORCE RESISTING SYSTEM: PLYWOOD SHEAR WALL ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE FLOOR LOAD DEAD LOAD = 15 PSF LIVE LOAD = 40 PSF TOTAL = 55 PSF PDC Pr o j e c t A d d r e s s : 2 2 0 1 W 7 t h S t r e e t S a n t a A n a , C A 9 2 7 0 3 . SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 24058 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 07/15/2024 GE N E R A L ST R U C T U R A L N O T E S S0.0 2201 W Seventh St 12/9/2024 PDC Pr o j e c t A d d r e s s : 2 2 0 1 W 7 t h S t r e e t S a n t a A n a , C A 9 2 7 0 3 . SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 24058 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 07/14/2024 1 2 3 4 6 TYPICAL FLOOR/ROOF OPENING DETAIL PROVIDE EDGE NAILING TO ALL EDGES OF OPENING. DOUBLE JOIST OR RAFTER EACH SIDE OF OPENINGPER SCHEDULE SIMPSON HANGER BLOCKING WHERE (PROVIDE FILLER REQUIRED)NOTE: JOIST OR RAFTER SEE PLAN OPENING SEE PLAN BEAM OR GIRDER 8'-0" MAX. 4' - 0 " M A X . TYPICAL CONNECTION DETAIL SIMPSON A34 2x STUD AT EACH SIDE w/ 16d AT 12"o.c. STAGGERED EACH SIDE OF POST @PROVIDE SIMPSON (4)A35 HI & LOW TOP PLATE. POST PER PLAN CEILING JOIST PARALLEL TO WALL NEW CEILING JOIST PER PLAN. 2x8 LEDGER w/ (2) 16d'S NAIL @ 16" OC INTO STUDS STUDS WALL CEILING JOIST PERPENDICULAR TO WALL NEW CEILING JOIST PER PLAN. 2x8 LEDGER w/ (2) 16d'S NAIL @ 16" OC INTO STUDS SIMPSON HANGER JOIST.1/2" DRYWALL AT BOTTOM OF CEILING JOISTS CEILING JOIST TO WALL DETAIL PERPENDIULAR TO ROOF FRAMING PARALLEL TO ROOF FRAMING 2x STUD SEE ARCH'L FOR SIZE AND SPACING 1/ 4 " ~ 1 / 2 " CL R . 1/ 4 " ~ 1 / 2 " CL R . 2x6 BLOCKING W/SIMPSON "LUS" HANGER EA. END SIMPSON "DTC" CLIP @48"o.c.SIMPSON "DTC" CLIP @48"o.c. CEILING SEE ARCH'L (2)2x TOP ~P'S CEILING JOIST TYPICAL NON-BEARING PARTITION WALL AT ROOF FRAMING DETAIL 9 10 11 STUD NOTCHING AND BORING DBL. TOP PLATES STUD, TYP. BORED HOLE MAX. DIAMETER 40% OF STUD DEPTH 5/8 " MIN. TO EDGE NOTCH MUST NOT EXCEED 25% OF STUD DEPTH BORED HOLES SHALL NOT BE LOCATED IN THE SAME CROSS SECTION OF CUT OR NOTCH IN STUD IF HOLE IS BETWEEN 40% AND 60% OF STUD DEPTH THEN STUD MUST BE DOUBLE AND NO MORE THAN TWO SUCCESSIVE STUDS ARE DOUBLE AND SO BORED 25% 40%5/8 " D NOTCH/BORE % OF STUD 2x4 STUDS 2x6 STUDS 2x8 STUDS 25% 40% 60% 7/8" 1-3/8" 2" 1-3/8" 2-1/8" 3-1/4" 1-3/4" 2-7/8" 4-1/4" DBL. TOP PLATES STUD, TYP. BORED HOLE MAX. DIAMETER 60% OF STUD DEPTH 5/8" MIN. BORED HOLES SHALL NOT BE LOCATED IN THE SAME CROSS SECTION OF CUT OR NOTCH IN STUD TO EDGE NOTCH MUST NOT EXCEED 40% OF STUD DEPTH 40% 60% MIN. D D60% MIN.D D D 60%D5/8 " D 12 13 ROOF/FLOOR DIAPHRAGM LAYOUT FIELD NAILING EDGE NAILING AT ALL BLOCKED EDGES BLK'G. AT DIAPHRAGM EDGES EDGE NAILING BLOKED SHT'G. UNBLOKED SHT'G. SHEATHING ABOVE FRAMING MEMBERS BELOW FIELD NAILING EDGE NAILING NO EDGE NAILING AT UNBLOCKED EDGES NOTE: 1.SEE SHEET EOR PLYWOOD THICKNESS, NAILING AND ADDITIONAL NOTES. 2.PANELS SHALL NOT BE LESS THAN 4 FT. X 8 ET. EXCEPT AT BOUNDARIES AND CHANGES IN FRAMING WHERE MINIMUM PANEL DIMENSIONS SHALL BE 24" UNLESS ALL EDGES OF THE UNDERSIZED PANELS ARE SUPPORTED BY FRAMING MEMBERS OR BLOCKING. 3.LONG DIMENSION OF PLYWOOD SHALL RUN ACROSS (PERPENDICULAR TO) JOISTS OR RAFTERS. 4.NAILS SHALL NOT BE DRIVEN THROUGH OUTER PLY. 5.BLOCKED SHT'G. (WHERE INDICATED) REQUIRES ALL PANELS EDGES TO RECEIVE EDGE NAILING. 6.WHERE JOISTS OR RAFTERS LAP SPLICE OCCURS AND PLYWOOD JOINT IS CONTINUOUS. VENEER TO WOOD WALL STEEL ANGLE SCHEDULE SIZE L4x3 1/2x3/8 L6x3 1/2x1/2 L7x4x5/8 8'-0" 14'-0" 16'-0" EXTERIORSHEATHING SEE ARCH. FOR INSULATION ANDMEMBRANE STUD WALLPER PLAN BEAM ORHEADERPER PLAN 1/2" DIA. LAG SCREW @12" O.C. WITH 2.5" MIN. EMBED TO BEAM OR HEADER LLV STEEL ANGLE SUPPORT 3'-6" VENEER HEIGHT MAX AND NEED TO EXTENT AND BEAR ON EACH SIDE OF OPENING 4" MIN. SEE SCHEDULE FOR SIZE FERO PAC-TIE WITH 2-#6 x 2" DECK SCREW AND WASHERS AS FOLLOWS: - TYPICAL AT 16" HORIZONTAL AND AT 24" VERTICAL - AROUND OPENINGS AT 12" HORIZONTAL AND AT 16" VERTICAL - NOT MORE THAN 12" FROM EDGE OF OPENINGS. - LOCATE ROW OF TIES MAX 12" ABOVE BEARING LEVEL AND 8" FROM TOP OF WALL. ADD 9 GAUGE WIRE JOINT REINF. @24" O.C. VERTICAL FOR BUILDING IN SEISMIC DESIGN CATEGORIES C, D, E, F.OPENING SPAN MAX. DRILLING HOLES AND NOTCHING OF THE JOIST D 13 SPAN HOLES AND NOTCHES ALLOWED 13 SPAN HOLES AND NOTCHES ALLOWED 13 SPAN HOLES AND NOTCHES ALLOWED D/3 (RAFT. OR C.J.) D/4 (FLOOR JOIST) D/ 6 D/ 6 MIN. 12"D/ 3 MI N . 2" MI N . 2" D D/ 4 ALTERNATE BOTTOM NOTCH NOTE: 1.DO NOT NOTCH BOTH TOP AND BOTTOM SURFACES WITHIN THE SAME 1/3 SPAN. 2.MAX. ALLOWED IS A COMBINATION OF TWO NOTCHES AND/OR HOLES PER 1/3 SPAN. 3.THIS DETAIL DOES NOT APPLY TO NOTCHES AND HOLES IN STRUCTURAL BEAMS, THEY MUST BE SPECIFICALLY DETAILED. 4.NOTCHES AND HOLES ARE NOT ALLOWED IN CANTILEVERED SEGMENTS OF JOISTS. 5.REFER TO MANUFACTURER'S RECOMMENDATIONS FOR NOTCHES AND HOLES WHERE I-JOIST TRUSSES ARE USED. 6.ANY OVER CUTS ARE TO BE INCLUDED IN THE MAXIMUM NOTCH DEPTH DIMENSION. JOIST SIZE MAX. NOTCH DEPTH: D/4 MAX. NOTCH DEPTH: D/6 MAX. SIZE HOLE: D/3 2X6 2X8 2X10 2X10 2X14 1-3/8" 1-3/4" 2-1/4" 2-3/4" 3-1/4" 7/8" 1-1/8" 1-1/2" 1-7/8" 2-1/8" 1-1/2" 2-3/8" 3" 3-3/4" 4-3/8" UPPER TOP PLATE 3/8" TYP. SHEAR WALL PENETRATIONS SHEAR WALL NAILING SHEATHING PER PLAN FIELD NAILING 6" M I N . HOLES TO BE MIN. 6" FROM PLATES, TYP. FOR HOLES UP TO 16" SQ., PROVIDE BLKG. AND E.N., HOLES LESS THAN 5" SQ. DO NOT REQUIRE BLKG. OR E.N. EDGE NAILING PER PLAN, TYP. FRAMING MEMBER PER SHEAR WALL SCHEDULE 1.SHEAR WALL EDGE NAILING TO HAVE MIN. EDGE DISTANCE OF 3/8". 2.WHEN SHEATHING IS NAILED TO TRIMMER, TRIMMER AND KING STUD TO BE STITCH NAILED TOGETHER WITH 16D'S, SPACING TO MATCH EDGE NAILING OF SHEAR WALL. 3.SHEAR WALL PENETRATIONS ARE TO BE IN CONFORMANCE WITH THE DETAIL BELOW. LIMIT ONE PENETRATION GREATER THAN 5" SQUARE PER STUD BAY. CUTS TO BE MINIMUM 16" FROM EDGE OF SHEAR WALL, ALL DIRECTIONS. 4.CONTACT ENGINEER OF RECORD FOR HOLES LARGER THAN 16" SQUARE. 5.TOTAL LENGTH OF OPENINGS SHALL NOT EXCEED 20% OF THE TOTAL WALL LENGTH. PRESSURE TREATED SILL PLATE w/ A.B.'s PER SHEAR WALL SCHEDULE HOLDOWN AS OCCURS, TYP. 2x STUD TYP. MIN 3x POST AT SHEAR WALL TYPES 1, 2 & 3. SHEAR PANEL w/ E.N. PER PLAN, MIN. WIDTH OF PANEL = 16" 2x4 STUDS AT 16"O.C. TYP., U.N.O. HDR. 6" DEEP & LESS PROVIDE (2) 16d, TRIM. TO HDR., ADD (1) 16d FOR EA. ADD'L 2" OF DEPTH USE LTP4 EA. SIDE WHEN GREATER THAN 2x KING POST 2x KING STUD AT NO HOLDOWN CONDITION OR POST PER PLAN AT HOLDOWN CONDITION. PER TABLE ABV. HEADER PER PLAN 2x TRIM. U.N.O. STITCH NAIL w/ 16d AT 6" o/c AT SHEAR WALLS, 16d AT 12" o/c AT NON-SHEAR WALLS E.N. PER SHEAR WALL SCHEDULE HOLDOWN AS OCCURS MIN. 1/8" STAGGER AT 2" E.N. FRAMING PLATE E.N. INTO UPPER TOP PLATE 1/8" 3/8"3/8" TYPICAL WALL FRAMING5 SHEAR WALL/ INTERSECTION PLYWOOD AT INTERSECTION w/ POST POST AT PER PLAN INTERSECTION w/o POST 16d @ 12" O.C. OUTSIDE CORNER w/ POST NOTE: SEE FRAMING PLAN FOR SHEAR WALL LOCATIONS, ORIENTATIONS AND SCHEDULE REFERENCES DOUBLE 2x, MIN. OUTSIDE CORNER w/o POST DOUBLE-SIDED WALL POST AT PER PLAN 16d @ 12" O.C.16d @ 12" O.C. FOR 2x STUD20d @ 6" O.C. FOR 3x STUD PLY. CONT. THRUWALL INTERSECTIONATDOUBLE-SIDEDWALL 16d @ 12" O.C. FOR 2x STUD 20d @ 6" O.C. FOR 3x STUD 2x OR 3x STUD AS REQ'D., TYP. PER S.W. SCHED. 7 8WOOD SHEARWALL SILL PLATE ANCHORAGE SHEARWALL WHERE OCCURS SILL PLATE ANCHORAGE PER SHEARWALL SCHEDULE CONCRETE SLAB OR PRECAST PLANK SHEARWALL SHEATHING SEE PLAN AND SCHEDULE PLATE WASHER 3 GA x 3 x 3- .229" MIN THICKNESS 12" MAX12" MAX E.Q.E.Q. 2x4 SHEAR WALLS AND ALL DOUBLE SIDED SHEAR WALLS TYPICAL NON-BEARING PARTITION WALL AT ROOF FRAMING DETAIL PERPENDIULAR TO TRUSS FRAMING PARALLEL TO TRUSS FRAMING 2x STUD SEE ARCH'L FOR SIZE AND SPACING 1/ 4 " ~ 1 / 2 " CL R . CL R . SIMPSON "DTC" CLIP @48"o.c. CEILING SEE ARCH'L (2)2x TOP ~P'S TRUSS BOTTOM CHORD 1/ 4 " ~ 1 / 2 " 2x6 BLOCKING W/SIMPSON "LUS" HANGER EA. END SIMPSON "DTC" CLIP @48"o.c. TYPICAL NON-BEARING PARTITION WALL AT SAWN LUMBER FRAMING DETAIL FLOOR JOIST PARALLEL TO WALL FLOOR JOIST PERPENDICULAR TO WALL 2x BLOCKING @ 24"o.c. (2)16d TOE NAIL AT JOIST TO PLATE 2x BLOCKING (CONT.)(2)16d TOE NAIL 16d @ 24"o.c.16d @ 16"o.c. TOP PLATE SPLICING, NOTCHING & BORING STANDARD PLATE SPLICE CONDITION ALL EXTERIOR, BEARING OR SHEAR WALLS, U.N.O. ON PLAN PLATE SPLICE COND. PER PLAN NON-LAPPED CHANNEL CONDITION ALLOWABLE TOP PLATE NOTCHING AND BORING ALL EXTERIOR BEARING OR SHEAR WALLS 2X UPPER TOP-PLATE (12)- 16d P-NAIL (GUN) EACH SIDE OF SPLICE, U.N.O. (ALT. CS16x36")^3 2X LOWER TOP-PLATE LOCATE STUD AT ALL SPLICES TYPICAL UPSIZED CONDITION WHERE SPECIFICALLY INDICATED ON PLANS ST OR MST TYPE STRAP MUST BE PLACED ON TOP OF UPPER PLATE THE NUMBER OF SPLICES MAY BE REDUCED BY NOT CUTTING PLATES AT INTERIOR WALL INTERSECTIONS THE NUMBER OF SPLICES MAY BE REDUCED BY NOT CUTTING PLATES AT INTERIOR WALL INTERSECTIONS SHIM W(2) - 16d (AT 1X PLATE COND. ONLY) FOR HEIGHT ADJUSTMENT LTP4 PER INTERSECTION CONT. 2-2X TOP PLTS. EXTERIOR WALL 1X OR 2X PLATE2X STUD AT CHANNEL EQ.EQ. REQUIRED TOP PALTE SPLICE (PER PLAN) STANDARD ST6224 MST48 CONT. DBL. TOP PLATES "NOTCH/BORE" DIMENSION OR +B2 B1 4,5 2,3STRAP NOT REQUIRED STRAP REQUIRED PLAN VIEW PLAN VIEW ST6236 1 MIN. 1-1/4" MIN. 1-3/4" MIN. 2-5/8" MIN. 3-1/2" MIN. 2-3/4" MIN. 1/2" to 1-1/4" MIN. 1-3/8" to 2-5/8" MIN. 1/2" to 1-3/4" MIN. 2-3/8" to 3-1/2" (1) - CS16 (1) - CS16 (1) - CS16 (1) - CS16 CALL ENGINEER MAX. 2" .2" TOP PLATES "NOTCH/BORE" CS16 W/(12)-8d NAILS ON EACH SIDE (WHERE REQ'D. BY CHART ABOVE)NOTCH CONDITION BORE CONDITION 1 6" A A B1 B2 48" MINIMUM LAP 14 TY P I C A L D E T A I L S S0.1 2201 W Seventh St 12/9/2024 PAD SCHEDULE PAD 2'-0" SQ. X 24" DEEP PAD W/ (3) #4 E.W. SYM. F2.0 2'-6" SQ. X 24" DEEP PAD W/ (3) #4 E.W. 3'-0" SQ. X 24" DEEP PAD W/ (3) #4 E.W. F2.5 F3.0 LEGEND 3'-6" SQ. X 24" DEEP PAD W/ (3) #4 E.W.F3.5 DESCRIPTIONSYM. F2.0 POST OR TRIMMER AS NOTED SDX X PAD NUMBER DETAIL NUMBER DETAIL SHEET NUMBER X'-X" X DROP IN SLAB (VERIFY PRIOR TO CONSTRUCTION) SHEAR PANEL LENGTH AND NUMBER, STRAP & POST EACH THE END SHEARWALL PER SHCEDULE & PLAN. REFER TO SD-0 FOR PANEL TYPE, MIN. 2-2x4 @ EA. END. INDICATES ROOF TRUSSES BY TRUSS SUPPLIER INDICATES FLOOR JOISTS BY JOIST SUPPLIER,OR U.N.O PER SCHEDULE & PLAN INDICATES DECK JOIST OR ROOF RAFTER PER SCHEDULE & PLAN X BEAM NUMBER, REFER TO REPORT CALCULATIONS KEY NOTE NUMBER BEARING WALL CALIFORNIA FRAMING XX GREATE BEAM @ FOUNDATION SEE PLAN FOR SIZE KEY NOTES FJ RR RT X NUMBER OF ANCHOR BOLTS LINE OF 2X FLAT BLOCKING W/ EDGE NAIL. & CONTINUOUS CS16 STRAP OVER U.N.O. SEE PLAN FOR NUMBER OF BAYS. BLOCKED FLOOR DIAPHRAGM W/ 10d's @ 4" O.C. B.N., 4" O.C. E.N. & 12" O.C. FIELD. BLOCKED ROOF DIAPHRAGM W/ 8d's @ 4" O.C. B.N., 4" O.C. E.N. & 12" O.C. FIELD. PROVIDE SOLID BLOCKING TRUSS HANGER BY TRUSS SUPPLIER CONTINUOUS FULL HT. BLKG. W/E.N. SEE PLANS FOR NUMBER OF BAYS ( U.N.O.) 1 2 3 4 5 6 EXISTING SLAB & FOOTING INDICATES CEILING JOIST PER SCHEDULE & PLANCJ NEW FOOTING 4'-0" SQ. X 24" DEEP PAD W/ (3) #4 E.W.F4.0 4'-6" SQ. X 24" DEEP PAD W/ (3) #4 E.W.F4.5 NEW SLAB CONSTRUCTION NOTES 1.REFER TO STRUCTURAL GENERAL NOTES AND DETAIL SHEETS (SD1 & S.0) FOR MORE INFORMATION. 2.CONTRACTOR IS RESPONSIBLE FOR VERIFYING PREFABRICATED SHEAR WALLS AND MATCH TOP PLATE HEIGHT AND WALL WIDTH AND NOTIFY ENGINEER OF RECORD IF DIFFERENT THAN PLANS. 3.AS AN ALTERNATE TO USING SIMPSON PRODUCTS OTHER CONNECTORS CAN BE USED, AS LONG AS THEIR CAPACITIES ARE EQUAL TO OR BETTER THAN SIMPSON'S. 4.USE SIMPSON " IUS " HANGERS FOR CONNECTION OF I-JOISTS TO OTHER FRAMING MEMBERS (U.N.O.) AND " LUS " HANGERS FOR CONNECTION OF SOLID JOISTS. 5.USE ST6224 STRAP FOR THE TOP PLATES SPLICE AT ROOF FRAMING LEVELS (5B/SD2.0), UNO ON PLANS. 6.USE ST22 STRAP FOR LEDGER SPLICES, UNO. 7.USE (1)CS16 X 3'-0" STRAP AT RIM JOISTS SPLICE, U.N.O ON PLANS. 1¼” MIN. LVL RIM JOISTS SHOULD BE USED AT ALL FLOOR FRAMING EDGES. 8.PLYWOOD IS APPLIED ON EITHER SIDE OF SHEAR WALLS 9.INTERIOR NON-BEARING WALLS MAY BE FRAMED WITH 2X STUDS AT 24" O.C., MAX. 10.HEARDER AT OPENING AT EXTERIOR & INTERIOR BEARING WALL SHOULD BE MIN. 4X6 ,U.N.O 11.HEADER AT NON-BEARING WALLS, USE 2X4 FOR OPENINGS UP TO 3'-0" MAX., (2)2X4 FOR OPENINGS UP TO 6'-0" MAX., 4X6 FOR OPENINGS UP TO 12'-0" MAX., (UNO). 12.2X6 WALL SHOULD BE AT PLUMPING WALL. 13.TOTAL MINIMUM NUMBER OF ANCHOR BOLTS. REQUIREMENTS. FOR NON-SHEAR WALLS, MASA/MASAP MUDSILL ANCHORS CAN BE USED IN LIEU OF ANCHOR BOLTS WITH END DISTANCE OF 4" MIN. PER ESR #2555. 14.FOUNDATION ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL PLATE SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. 15.SIMPSON SET-XP EPOXY ESR-2508 SPECIAL INSPECTION REQUIRED LIVING ROOM KITCHEN CLOSET CLOSET CLOSET CLOSET BEDROOM BEDROOM BEDROOM BATHROOM GARAGE WALL WALL WALL LEGEND 2 4'-0" HD U 2 2 HD U 2 9 SD1 2 6'-3" HD U 2 3 HD U 2 9 SD1 9 SD1 9 SD1 4 SD1 4 SD1 F2.5 CBS Q 4 6 8 SD1 EXISTING RAISER FLOOR EXISTING CONCRETE SLAB 3 SD1 TYP. EXISTING STEM FOOTING 5 SD1 F2.0 18'-10" 7' - 8 " LIVING ROOM KITCHEN CLOSET CLOSET CLOSET CLOSET BEDROOM BEDROOM BEDROOM BATHROOM GARAGE WALL WALL WALL LEGEND (E ) H D R . (E) H D R . (E ) H D R . (E) HDR.(E) HDR. (E) HDR. (E ) H D R . (E ) H D R . 4X6 4X6 4X6 A B 2 4'-0" 4X 4 4X 4 14A SD1 2 6'-3" 4X 4 4X 4 14A SD1 E2 E2 E1 E3 1 10 3/4"X12" GLB CL'G BM E E E 4X12 4X12 4X8 2 18 SD1 18 SD1 HUC46 17 SD1 E ALL WALLS SHALL BE VERIFIED BY EOR BEFORE REMOVE THEM EX I S T I N G R O O F S Y S T E M TO B E R E M A I N E D , VE R I F Y O N F I E L D . EXISTING ROOF SYSTEM TO BE REMAINED, VERIFY ON FIELD. 10 S0.1 TYP. (E) H I P B M (E) H I P B M (E ) C L ' G B M (E) R.B. HU. (E) K.P . VERIF Y O N F I E L D 19 SD1 TYP. FOUNDATION PLAN SCALE : 1/4" = 1'-0" PDC Pr o j e c t A d d r e s s : 2 2 0 1 W 7 t h S t r e e t S a n t a A n a , C A 9 2 7 0 3 . SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 24058 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 07/15/2024 ROOF FRAMING PLAN SCALE : 1/4" = 1'-0" FO U N D A T I O N P L A N & F R A M I N G P L A N S1.0 2201 W Seventh St 12/9/2024 PDC Pr o j e c t A d d r e s s : 2 2 0 1 W 7 t h S t r e e t S a n t a A n a , C A 9 2 7 0 3 . SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 24058 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 07/15/2024 ST R U C T U R A L D E T A I L S SD1 1 2 3 4 5 6 7 8 9 10 11 WALL FOOTING DETAIL, TYP.(W/ NEW FOOTING) 8" M I N JOIST I TO STEM WALL 18 " M I N . 2x BLOCKING w/ A35 @ 16" O.C. TO SILL PLATE 15" 8" 8" 2-#5 @ TOP & 2-#5 @ BOTT. 2x STUDS 2x6 F.J PLYWOOD SHEATHING TYP. 2x P.T SILL PLATE w/ 1/2"Øx7" MIN EMBED. A.B @ 4'-0" O.C. OR 24" O.C. FOR SHEAR WALLS w/ 3" SQ.x0.229" PLATE WHASHERS 15 " M I N . 3" CL E A R B.N. E.N. SHEARWALL WHERE' OCCURE SCREED @ STUCCO FINISH WALL FOOTING DETAIL, TYP.(W/ NEW FOOTING) JOIST // TO STEM WALL 8" 15" 18 " M I N . 2x BLOCKING @ 32" OC 2#5 @ TOP & 2 #5 @ BOTT. 2x6 F.J TYP. 2x P.T SILL PLATE w/ 1/2"Øx7" MIN EMBED. A.B @ 4'-0" O.C., OR 24" O.C. FOR SHEAR WALLS w/ 3" SQ x 0.229" PLATE WASHERS PLYWOOD SHEATHING 8" M I N 12 " 24 " M I N . 3" CL E A R 2x BLOCKING w/ A35 @ 16" O.C. TO SILL PLATE 2x STUDS B.N. E.N. SHEARWALL WHERE' OCCURE SCREED @ STUCCO FINISH IN SHEAR WALL SCHEDULE w/ STANDARD WASHER UNLESS NOTED OTHERWISE 10" MINIMUM EMBEDMENT PLAN MASONRY BLOCK FOUNDATION REINFORCING NOT SHOWN FOR CLARITY PER PLAN 2x STUDS BEARING ON CONCRETE OR PRESSURE TREAT ALL SILLS 9" M A X . 6" M I N . NOTE: SILL PL 5/8"Ø ANCHOR BOLT @ 4'-0"o.c. MAXIMUM 6" MIN. 9" MAX.9" MAX. 6" MIN. w/(4)16d 2x PL END NAILS (2)16d TYPICAL w/(2)16d 2x BLOCKING THAN 1/3 WIDTH OF SILL PL. NOTCH OR HOLE IS MORE NOTCH OR HOLE WHERE w/(4)16d EACH SIDE OF PROVIDE 1 1/2"x 1/8" STRAP 9" MAX. 6" MIN. 5" MAX.MAX. 5" PROVIDE HOT DIPPED GALVANIZED ANCHOR BOLTS AND PLATE WASHERS PER PROJECT SPECIFICATIONS TYPICAL SILL PLATE AT FOUNDATION DETAIL TYP. REINFORCING DETAILS BEND R= 5(d) FOR #14 THRU #18 LAP SPLICE STIRRUP 6(d ) M I N . TIE OR HOOK 6(d ) M I N . MADE COLD DI M E N S I O N DE T A I L I N G OR 3 " M I N . - ALL BENDS SHALL BE STIRRUP ALT. 135° BENDS - PUT CROSSTIE W/ EACH D= 4(d) FOR #3 THRU #5 D= 6(d) FOR #6 THRU #8 OR 3 " M I N . 12 ( d ) F O R # 6 T H R U # 8 DI M E N S I O N DE T A I L I N G NOTES: CROSSTIE MEMBER BELOW, EXCLUDE CONCRETE IS CAST IN THE THAN 12 INCHES OF FRESH BARS SO PLACED THAT MORE FOR TOP BARS (HORIZONTAL * INCREASE LENGTH BY 30% WIRE TIE END WALLS) D D 48(d) MASONRY (U.N.O.) 48(d) * IN CONCRETE 90° BEND 8(d) R R= 4(d) FOR #9 THRU #11 R= 3(d) FOR #3 THRU #8 2 1/2" MIN.8(d) 180° BEND R12 " 4(d) OR 4" M I N . O R 4" M I N . O R 6(d) POST BASE DETAIL OF COLUMN BASE. 12" 12" THRU STIRRUP #3 MIN. "V" BAR BENT CB/LCB/CBSQ PER PLAN. SIMPSON COLUMN BASE WHERE OCCURS. 1" CL R TOP OF CONCRETE SLAB CLR3" 3" 8" M I N . 4" 3" BATTER SEE PLANS PAD FOOTING PER PLAN. POST PER PLAN. GIRDER BEAM WHERE OCCUR SIMPSON HANGERPER PLAN RETROFIT FOR SHEAR WALL NOTE: EXISTING WALL TO BE USED FOR SHEAR WALL REQUIRED SILL PLATE ANCHOR BOLTS PER SHEAR WALL SCHEDULE SPECIAL INSPECTION REQUIRED 7" M I N . 2" MIN. FOR 2X4 WALL 3 1/2 " MIN. FOR 2X6 WALL INJECTION EPOXY REFER NOTES FOR LENGHT EMBEDMENT. 5 8"Ø ALL-THREADED ROD, 7 8" DRILL BIT w/ SIMP. SET-XP EPOXY, ICC-ESR-2508 w/ 3x3x0.229 PLATE WASHER EXISTING F.J 18 " M I N . HDU2/HDU4 HOLDDOWN w/ SDS2.5 SCREWS NOTE: SIMPSON SET-XP EPOXY ESR-2508 SPECIAL INSPECTION REQUIRED (ALT.SIMPSON SET-3G ESR-4057 SPECIAL INSPECTION REQUIRED) SIMP. CNW 5/8 2" MIN. 6" MIN FOOTING DRILL 5 8"Ø HOLE FOR 5 8"Ø X 9" EMBED. ALL-THREADED ROD w/ SIMPSON "SET" EPOXY (ALT.SIMPSON SET-3G) w/ SPACING PER SHEARWALL SCHEDULE EXISTING STEM CNW 5/8 Simpson Strong-Tie DRILL 5 8"Ø HOLE FOR 5 8"DIA. WITH 16" MIN. EMBEDMENT ALL-THREADED ROD w/ SIMPSON "SET" EPOXY INTO EXIST. FOOTING HOLDOWN DETAIL INTO CONC. 4X OR 2-2X BLKG. BELOW POST. FLOOR JOIST2X BLOCKING OR 2X MEMBER PLYWOOD SHEATHING 2X STUDS @ 16" O.C. 2X STUDS @ 16" O.C. NONE BEARING WALL TO FLOOR JOIST FLOOR JOIST. PLYWOOD SHEATHING 2X4 FLAT BLOCKING @ 16" O.C. SILL PLATE POST & BEAM CONNECTION BM., SEE PLAN POST, SEE PLAN. EQ . EQ . STRAP A CAPACITY - 5600# 2900# MSTA12 EA. SIDE (1) CS16B (2) CS16C OF EACH STRAPOVERALL LENGTH 12" 24" 24" SIMPSON STRAP EACH SIDE OF BEAM TO POST. ALT. TO MSTA12 STRAPS, USE 2X KING STUD EACH SIDE OF BEAM TO POST & NAIL W/ 16d'S @ 16" O.C. TO POST & MIN. (5) 16d'S TO BEAM. CALIF. FRAMING DETAIL 2X6 FLAT W/ 2-16d TO EA. ROOF TRUSS/RAFTER RUN LOWER ROOFSHEATHING TO SUPPORTING WALL/BEAM AND PROVIDE SHEAR TRANSFER AT THAT LOCATION 2X4 RR @ CALIFORNIA FRAMING MAX. SPAN = 8' U.N.O. MAIN ROOF FRAMING RAFTER OR ROOF TRUSS ROOF RAFTER ROOF SHEATHING B.N. ROOF RAFTER W/ HANGERS TO RIDGE ROOF SHEATHING 2X6 RIDGE @ 2X4 RAFTERS @ CALIFORNIA FRAMING B.N.B.N. ROOF BRACE WHERE REQ'D TO LIMIT SPANON 2X4 R.R. TO 8'-0" MAX. U.N.O. (2)16d TOENAIL RR TO RR. TYPICAL TOP PLATE SPLICE ST22 STRAP @ RIDGE OF RAKE WALL 18-16d SINKERS @ SPLICE, STAGGERED DO NOT SPLIT TOP PLATE WITH SPLICE NAILING, SEE TABLE BELOW. STUDS @ 16" O.C. 2-16d FROM TOP PLATE TO BOTTOM PLATE OVER EACH STUD 2-16d FROM PLATE TO EA. STUD 2-2X TOP PLATE 4' NOTE: SPLICE REQUIRED AT ALL PLATE BREAKS AND ALSO AT CHANNELS FOR INTERSECTING WALLS AT ANY EXTERIOR WALL, BEARING WALL, OR SHEAR WALL NO. OF 16d SINKER MIN. PLATE LAP ALT. STRAP w/ 16d SINKER ST22 ST6224 ST6236 MST37 MSTC52 CMST12x72" 8 FT. 42 GF 36 8 FT.8 FT. 32 ED 24 6 FT.6 FT. 22 CB 16 4 FT. 10 A 4 FT. MST60 TYPICAL FLUSH BEAM PERPENDICULAR TO WALL DETAIL BEAM PER PLAN POST OR DOUBLE STUDS(PROVIDE 16d @ 12"o.c.AT DOUBLE STUDS) (2)2x TOP ~PS PLYWOOD SHEATHINGPER PLAN EACH SIDE FOR BEAMS9~4" DEEP AND LARGER PROVIDE SIMPSON A35 TYPICAL STUD WALL FRAMING AT OPENING DETAIL (2)10d TOE 16d @ 12"o.c. WIDER THAN 6'-0") TRIMMER AT OPENING 2x TRIMMER (2)2x U.N.O. SILL ~P THAN 4'-0") SILL AT OPENING WIDER WHERE OCCURS (2)2x 2x WINDOW SILL SEE PLAN POST AT HOLDOWNS DOUBLE STUDS OR 2x STUDS @ 16"o.c. TOP AND BOTTOM 6'-0") W/ SIMPSON A34 OPENING WIDER THAN (2)2x THRU STUDS AT (1)2x THRU STUD (USE HEADER DEPTH) OF ADDITIONAL (2)16d FOR EA. 2" (2)16d MIN. (ADD THAN 8'-0" OPENING WIDER SIMPSON A34 AT NAILS STAGGER DETAILS SEE CBC, TABLE 25Q, OR FOR BALANCE OF NAILING, U.N.O. ON PLANS) OPENING HEADER SCHEDULE WIDTH 10'-0" 12'-0" 8'-0" 6'-0" 4'-0" MAX. VERTICAL AND @ 8'-0"o.c. STOPS AT CEILING PROVIDE 2x FIRE NOTE: STUD WIDTH WIDTH SAME AS BEARING 10" 12" NON-BEARING 8" 6" 4" 12" 14" 8" 10" 6" MIN. NOMINAL HEADER ''D'' TO 6'-0" ONLY) (AT OPENINGS UP BUILT-UPSOLID '' D ' ' DE P T H HD R UP PER SCHEDULE HEADER (SOLID, BUILT- (2)2x TOP ~PS EA. SIDE STAGGER w/ 16d @ 12"o.c. CONT. PLYWD. SHIM 2x EA. SIDE ANDNOTE: CJ W/ 8-16d FACE NAILS LARGER BLOCK (RIPPED TO CORRECT SIZE) FOR GAPS LARGER THAN 1". USE FULL DEPTH BLKG. INSTALL LS70'S WHERE GAP EXCEEDS 1/4". USE NEXT H1'S @ 24" O.C. MAY BE INSTALLED IN LIEU OF A35'S FOR SHEAR TRANSFER. DROP BM. WHERE OCCURS HEADER WHERE OCCURS 2X BEVELED BLOCKING W/E.N. & A35 @ 24" O.C. (SEE ADDITIONAL A35 REQMTS. @ SHEAR WALLS) DBL 2X TOP PLATE2X STUDS @ 16" O.C. SHEAR PANEL WHERE OCCURS B.N. SEAT CUT ALL RAFTERS. DO NOT OVERCUT. ALT. LOCATION OF BLKG. NOTES: ROOF SHEATHING RR W/ SEAT CUT AT WALL B.N. ROOF RAFTER PERPENDICULAR TO EXT. WALL 30" MAX. 1X6 STARTER BOARD-SHIPLAP AT EXPOSED EAVES 2X ROSA FASICA SIMPSON H2.5A @ 48" O.C. U.N.O. GABLE END WALL 2x STUDS BALLOON FRAME 16d NAILS @ 8" OC AFTER ROOF IS LOADED 2x BLOCKING D.F #2 FLAT LOOKOUTS 2x4 @ 24" OC OR 2x6 @ 32" OC. TAKE BACK TO 2ND RAFTER (MAX 18" TOTAL OVEHANG). SOLID SHIM UNDER EA. LOOKOUT HOLD TOP OF WALL DOWN 3 4" + FROM TOP OF UNLOADED RAFTERE.N #FULL HEIGHT SEE PLAN E.N (2)-16d @ EA. END OF LOOKOUT ROOF SHEATHING E.N A35F MAY BE OMITTED WHERE SHEAR WALL MATERIAL APPED +4" OVER RIM. PROVIDE A35F @ NON-SHEAR SEQUENTS E.N E.N SIMP. A35F @ 48" OC DTL 16d 'S A35'S A 8" OC 32" OC B 6" OC 24" OC C 4" OC 16" OC D 3" OC 12" OC NOTCH JOIST FOR LOOKOUTS POST SEE PLAN BEAM PER. PLAN BEAM PER. PLAN SIMPSON HUC CONNECTION DETAIL (N) BEAM SEE PLAN BOUNDARY NAILING (E) CEILING JOIST SEE PLAN PLYWOOD SHEATHING EACH SIDE SIMPSON LUS HANGER TYPICAL JOIST TO FLUSH BEAM CONNECTION DETAIL TO BE REMAINED VERIFY ON FIELD. 12 13 14 15 16 17 18HOLDOWN DETAIL APLICATION OF MTS & HTS APPLICATION OF CS16's 5 5/16" (2) HTS20B(2) CS16 ON 2-2X4 2090# 4200#(3) CS16 ON 4X6C (4) HTS20 NAILS FOR HTS20 USE 8d SINKER NAILS FOR CS16's. - CUT CS STRAP TO MEET MIN. END LENGTH & USE MIN. - PROVIDE 1 1/2" SPACING BTWN ROWS OF NAILS @ MULTIPLE CS STRAPS. CAPACITY 1650# - USE 10d SINKER FOR MTS12 USE 10d COMMON (1) CS16 ON 2X4 STRAP TYPE A ALT. (2) MTS12 (16) 8d's @ EACH END OF EACH STRAP. FOR (2) MTS12 USE (2) ST12,FOR (2) HTS20 USE (2) ST2122 NOTES: AND FOR (4) HTS20 USE (2) ST6224. - REFER TO 17/SN2 FOR CS16 NAILING PATTERN. FLUSH BM/HDR PER PLAN. USE DETAIL 5/SD2 FOR CONNECTION OF BM/HDR TO POST (U.N.O.). STRAP TYPE, SEE TABLE. DBL. TOP PLATE OR DROP BM. PER PLAN. MULTI STUD 2X STUD MIN. 4X8 SOLID BLOCKING. OR POST. W/16 d's @ 6" O.C. FLUSH BM/HDR PER PLAN. MULTI STUD OR POST. EN D L E N G T H = 1 8 " END LENGTH = 18" 19 NEW PAD AT (E) FOOTING SEE PLANS MIN. 24" SQ. 3" CL R FLOOR SHEATHING (E) FLOOR JOIST. EXISTING WALL. EXISTING FOOTING. (4) #4 DOWELS MIN 4" EMBEDMENT TO (E) CONCRETE FOOTING. W/ SIMPSON SET-XP EPOXY, ESR #2508. PERIODIC SPECIAL INSPECTION IS REQ'D. 2201 W Seventh St 12/9/2024 SHEET NUMBER CONSULTANT REVISIONS The above drawings, specifications, ideas, and arrangements represented thereby are and shall remain property of G Design and no part thereof shall be copied, disclosed to others or used in connection with any other project other than the specific project for which they have been prepared and developed, without the written consent of G Design. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and this office must be notified of any variations from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceding with fabrication. 2024 DATE SCALE DRAWN JOB no. GQ A-002 TI T L E 2 4 7th STREET REMODEL 2201 W 7th STREET SANTA ANA, CA 92703 OCT 18, 2024 GIOVANNI QUINTERO 167 OAHU WAYPLACENTIA, CA 92870 TELEPHONE: 310 749.7536 E-MAIL: LOOKING4GIO@GMAIL.COM AUG 12, 2024 OCT 18, 2024 CORR #1 Atousa Yazdanfar Energy Compliance Services 5702 Hersholt Avenue Lakewood , CA 90712 562.522.4258 7/18/2024 Giovanni Quintero G x G Design 167 Oahu Way Plactentia, CA 92870 (310) 749-7536 GIOVANNI QUINTERO 10-17-2014 2201 W Seventh St 12/9/2024 PAD SCHEDULE PAD 2'-0" SQ. X 24" DEEP PAD W/ (3) #4 E.W. SYM. F2.0 2'-6" SQ. X 24" DEEP PAD W/ (3) #4 E.W. 3'-0" SQ. X 24" DEEP PAD W/ (3) #4 E.W. F2.5 F3.0 LEGEND 3'-6" SQ. X 24" DEEP PAD W/ (3) #4 E.W.F3.5 DESCRIPTIONSYM. F2.0 POST OR TRIMMER AS NOTED SDX X PAD NUMBER DETAIL NUMBER DETAIL SHEET NUMBER X'-X" X DROP IN SLAB (VERIFY PRIOR TO CONSTRUCTION) SHEAR PANEL LENGTH AND NUMBER, STRAP & POST EACH THE END SHEARWALL PER SHCEDULE & PLAN. REFER TO SD-0 FOR PANEL TYPE, MIN. 2-2x4 @ EA. END. INDICATES ROOF TRUSSES BY TRUSS SUPPLIER INDICATES FLOOR JOISTS BY JOIST SUPPLIER,OR U.N.O PER SCHEDULE & PLAN INDICATES DECK JOIST OR ROOF RAFTER PER SCHEDULE & PLAN X BEAM NUMBER, REFER TO REPORT CALCULATIONS KEY NOTE NUMBER BEARING WALL CALIFORNIA FRAMING XX GREATE BEAM @ FOUNDATION SEE PLAN FOR SIZE KEY NOTES FJ RR RT X NUMBER OF ANCHOR BOLTS LINE OF 2X FLAT BLOCKING W/ EDGE NAIL. & CONTINUOUS CS16 STRAP OVER U.N.O. SEE PLAN FOR NUMBER OF BAYS. BLOCKED FLOOR DIAPHRAGM W/ 10d's @ 4" O.C. B.N., 4" O.C. E.N. & 12" O.C. FIELD. BLOCKED ROOF DIAPHRAGM W/ 8d's @ 4" O.C. B.N., 4" O.C. E.N. & 12" O.C. FIELD. PROVIDE SOLID BLOCKING TRUSS HANGER BY TRUSS SUPPLIER CONTINUOUS FULL HT. BLKG. W/E.N. SEE PLANS FOR NUMBER OF BAYS ( U.N.O.) 1 2 3 4 5 6 EXISTING SLAB & FOOTING INDICATES CEILING JOIST PER SCHEDULE & PLANCJ NEW FOOTING 4'-0" SQ. X 24" DEEP PAD W/ (3) #4 E.W.F4.0 4'-6" SQ. X 24" DEEP PAD W/ (3) #4 E.W.F4.5 NEW SLAB CONSTRUCTION NOTES 1.REFER TO STRUCTURAL GENERAL NOTES AND DETAIL SHEETS (SD1 & S.0) FOR MORE INFORMATION. 2.CONTRACTOR IS RESPONSIBLE FOR VERIFYING PREFABRICATED SHEAR WALLS AND MATCH TOP PLATE HEIGHT AND WALL WIDTH AND NOTIFY ENGINEER OF RECORD IF DIFFERENT THAN PLANS. 3.AS AN ALTERNATE TO USING SIMPSON PRODUCTS OTHER CONNECTORS CAN BE USED, AS LONG AS THEIR CAPACITIES ARE EQUAL TO OR BETTER THAN SIMPSON'S. 4.USE SIMPSON " IUS " HANGERS FOR CONNECTION OF I-JOISTS TO OTHER FRAMING MEMBERS (U.N.O.) AND " LUS " HANGERS FOR CONNECTION OF SOLID JOISTS. 5.USE ST6224 STRAP FOR THE TOP PLATES SPLICE AT ROOF FRAMING LEVELS (5B/SD2.0), UNO ON PLANS. 6.USE ST22 STRAP FOR LEDGER SPLICES, UNO. 7.USE (1)CS16 X 3'-0" STRAP AT RIM JOISTS SPLICE, U.N.O ON PLANS. 1¼” MIN. LVL RIM JOISTS SHOULD BE USED AT ALL FLOOR FRAMING EDGES. 8.PLYWOOD IS APPLIED ON EITHER SIDE OF SHEAR WALLS 9.INTERIOR NON-BEARING WALLS MAY BE FRAMED WITH 2X STUDS AT 24" O.C., MAX. 10.HEARDER AT OPENING AT EXTERIOR & INTERIOR BEARING WALL SHOULD BE MIN. 4X6 ,U.N.O 11.HEADER AT NON-BEARING WALLS, USE 2X4 FOR OPENINGS UP TO 3'-0" MAX., (2)2X4 FOR OPENINGS UP TO 6'-0" MAX., 4X6 FOR OPENINGS UP TO 12'-0" MAX., (UNO). 12.2X6 WALL SHOULD BE AT PLUMPING WALL. 13.TOTAL MINIMUM NUMBER OF ANCHOR BOLTS. REQUIREMENTS. FOR NON-SHEAR WALLS, MASA/MASAP MUDSILL ANCHORS CAN BE USED IN LIEU OF ANCHOR BOLTS WITH END DISTANCE OF 4" MIN. PER ESR #2555. 14.FOUNDATION ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL PLATE SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. 15.SIMPSON SET-XP EPOXY ESR-2508 SPECIAL INSPECTION REQUIRED LIVING ROOM KITCHEN CLOSET CLOSET CLOSET CLOSET BEDROOM BEDROOM BEDROOM BATHROOM GARAGE WALL WALL WALL LEGEND 2 4'-0" HD U 2 2 HD U 2 9 SD1 2 6'-3" HD U 2 3 HD U 2 9 SD1 9 SD1 9 SD1 4 SD1 4 SD1 F2.5 CBS Q 4 6 8 SD1 EXISTING RAISER FLOOR EXISTING CONCRETE SLAB 3 SD1 TYP. EXISTING STEM FOOTING 5 SD1 F2.0 18'-10" 7' - 8 " LIVING ROOM KITCHEN CLOSET CLOSET CLOSET CLOSET BEDROOM BEDROOM BEDROOM BATHROOM GARAGE WALL WALL WALL LEGEND (E ) H D R . (E) H D R . (E ) H D R . (E) HDR.(E) HDR. (E) HDR. (E ) H D R . (E ) H D R . 4X6 4X6 4X6 A B 2 4'-0" 4X 4 4X 4 14A SD1 2 6'-3" 4X 4 4X 4 14A SD1 E2 E2 E1 E3 1 10 3/4"X12" GLB CL'G BM E E E 4X12 4X12 4X8 2 18 SD1 18 SD1 HUC46 17 SD1 E ALL WALLS SHALL BE VERIFIED BY EOR BEFORE REMOVE THEM EX I S T I N G R O O F S Y S T E M TO B E R E M A I N E D , VE R I F Y O N F I E L D . EXISTING ROOF SYSTEM TO BE REMAINED, VERIFY ON FIELD. 10 S0.1 TYP. (E) H I P B M (E) H I P B M (E ) C L ' G B M (E) R.B. HU. (E) K.P . VERIF Y O N F I E L D 19 SD1 TYP. FOUNDATION PLAN SCALE : 1/4" = 1'-0" PDC Pr o j e c t A d d r e s s : 2 2 0 1 W 7 t h S t r e e t S a n t a A n a , C A 9 2 7 0 3 . SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 24058 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 07/15/2024 ROOF FRAMING PLAN SCALE : 1/4" = 1'-0" FO U N D A T I O N P L A N & F R A M I N G P L A N S1.0 2201 W Seventh St 12/9/2024 TUNG THANH VO, M.S., P.E. 11122 BIXLER CIR GARDEN GROVE CA 92840 BUS: 714-928-2006 FAX: 714-901-9535 EMAIL: tungcivil2018@gmail.com STRUCTURAL ANALYSIS ********************** SUBMITAL FOR BUILDING DEPARTMENT CLIENT : REMODEL. PROJECT NAME : REMODEL. LOCATION : 2201 W 7TH STREET SANTA ANA, CA 92703. JOB NUMBER : 24058. 1st SUBMITAL: July 11, 2024 VERTICAL, LATERAL DESIGNED BY: TUNG VO, M.S., P.E. 2201 W Seventh St 12/9/2024 DESIGN CRITERIA SHEET Job# 24058 CODE: 2022 CALIFORNIA BUILDING CODE In all cases calculations will supersede this design criteria sheet. TIMBER Douglas fir-larch-19% max. moisture content. 4X Members: No .2 or Better 6X,8X Beams and Headers: No.1 or Better 2X Joists and Rafters: No. 2 or Better Plates and Blocking: Standard Grade or Better Studs: Stud Grade or Better Mud Sills: Pressure Treated Utility Grade or Better CONCRETE 1.Drypack shall be composed of one part Portland cement to not more than three-part sand. 2.All structural concrete…………………………. f’c=2500 psi w/inspection. All slab-on –grate/continuous footing /pads……… f’c=2500 psi w/inspection. All concrete shall reach minimum compressive strength at 28 days. REINFORCING STEEL 1. All reinforcing shall be A.S.T.M.A-615-40 for #4 bars and smaller, A-615-60 for #5 bars and larger. Welded wire fabric to be A.S.T.M. A-185, lab 1-1/2 spaces ,9” min. 2. Development length of Tension Bars shall be calculated per ACI318-19 Section 12.2.2. Class B splice =1.3xld. Splice lengths for 2500 psi concrete is: # 4 Bars (40k) =21”, #5 Bars (60k) =39”, #6 Bars (60k) =47” (30 dia. for compression). Masonry reinforcement shall have lappings of 48dia.or 2’-0”. This is in all cases U.N.O. 3. All reinforcing bars shall be accurately and securely placed before pouring concrete, or grouting masonry. 4. Concrete protection for reinforcement shall be at least equal to the diameter of the bars. Cover for cast-in-place concrete shall be as follows, U.N.O: A. Concrete cast against & permanently exposed to earth…………………3” B. Concrete exposed to earth or weather <= #5 Bar ………………………1 ½” #6#18 bars 2” C. Concrete not exposed to weather or in contact with ground Slab, wall, joist, <= #11bars …………………………………………… 3/4” Beams & Columns: Primary reinforcement, ties, stirrups, spirals………….1 ½” STRUCTURAL STEEL 1. Fabrication and erection of structural steel shall be in accordance with “specification for the Design, Fabrication and Erection of Structural Steel Buildings “, AISC, current edition. Steel to conform to ASTM A992.Round pipe columns shall conform to ASTM A35, Grade B.Square /Rectangular Steel tubes ASTM A500,Grade B . 2. All welding shall be performed by certified welders, using the Electric Shielded Arc Process at licensed shops or otherwise approved by the Bldg. Dept. Continuous inspection required for all field welding. 3. All steel exposed to weather shall be hot –dip galvanized after fabrication, or other approved weatherproofing method 4. Where finish is attached to structure steel, provide ½” f both holes @ 4’-0” O.C. for attachment of nailers, U.N.O. see architectural drawings for finishes (nelson studs ½”x3” CPL may replace bolts). MASONY 1. Concrete block shall be of size shown on architectural drawing and/or called for in specifications and conform to ASTM C-90-09, grade A normal weight units with max. linear shrinkage of 0.06% 2. All vertical reinforcing in masonry walls not retaining earth shall be located in the center of the wall (U.N.O.), retaining walls are to be as shown in details. 3. All cells with steel are to be solid grouted (except retaining walls where all cells are to be solid grouted). 2201 W Seventh St 12/9/2024 LOADING & LATERAL ANALYSIS (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) Job Number : 24058 Plan : GENERAL INPUT : Code :2022 CBC Wind Speed:110 mph Risk Category :II Wind Exposure:C Importance Factor, I (Seis.)1.00 Mean Roof Height :10 ft Soil Site Class :D Building With, B :37 ft Seismic Category :D Building Lenght, L :54.75 ft Spectral Accel., Ss :1.306 Typ. Roof Slope:4/12 Spectral Accel., S1 :0.465 Risk Category II Structure Height, hn :10 ft Topographic Factor Kzt 1.00 Seismic Resist. System (R) :6.5 Direction Factor Kd :0.85 Soil Bearing Pressure:1500 psf Gust Effect Factor G :0.85 Concrete Strength:2500 psi Gcpi(+/-)0.18 Foundation Type : Conventional Load Combination Factor (W) :1.00 ANALYSIS SEISMIC DESIGN :(Using Equivalent Force Procedure per ASCE 7-16) Site Coefficients : Fa ==1.20 (ASCE 7-16 Table 11.4-1) Fv ==1.80 (ASCE 7-16 Table 11.4-2) Maximum Spectral Response Accelerations : SMS=Fa*Ss =1.57 (USGS Seismic Design Geodatabase) SM1=Fv*S1 =0.84 (USGS Seismic Design Geodatabase) Design Spectral Accelerations : SDS=SMS*2/3 =1.045 SD1=SM1*2/3 =0.56 Determine Building Period : Ta=Ct*(hn^x)=0.112 sec. (Approximate Fundemental Period using Eq. 12.8-7) TL =8.000 sec. (Long-period transition period per ASCE 7-16 Maps 22-15/20) Ct =0.020 x =0.750 Seismic Response Coefficients : Cs=0.7*SDS*I/(R)=0.113 (ASCE 7-16 Section 12.8-2)CONTROL Cs-max 0.763 (Eq. 12.8-3 & 12.8-4) Cs-min 0.010 (Eq. 12.8-5 & 12.8-6) ANALYSIS WIND DESIGN :(MWFRS Directional Procedure Chapter 27 Part1 per ASCE 7-16 for Building of any Height- See detail on pages Lateral Analytical Section ) LOADDING CONDITIONS : ROOF LOADING :FLOOR LOADING : Slope : 4/12 Roof Material : 5.50 Floor Material : 4.00 Built-up : 3.50 Built-up : 0.00 Sheathing : 1.50 Sheathing : 3.00 Roof Rafters : 1.50 Floor Joist : 1.50 Ceiling Joist : 1.50 Carpet : 1.00 Drywall : 1.50 Drywall : 2.50 Miscellaneous : 1.00 Miscellaneous : 3.00 Total Dead Load(D.L) : 16.00 psf Total Dead Load(D.L) : 15.00 psf Live Load (L.L) : 20.00 psf Live Load (L.L) : 40.00 psf Snow Load : WALL LOADING :CEILING LOADING : Exterier Wall :(DL )15.00 psf Dead Load :6.00 psf Interier Wall :10.00 psf Live Load :10.00 psf 2201 W Seventh St 12/9/2024 BEAM DESIGN Job Number 24058 Plan :1 Code : AF&PA NDS-2018 Design Method:ASD Load Combination: 2021 IBC/2022 CBC & ASCE 7-16 All timber shall be Douglas Fir-Larch-19% max .moisture content. Timber Properties : Sawn Lumber(DFL) 2X Josit& Rafters(No.2) 4X Swan Beams(No.2) 6X Swan Beams(No.1) Glued Laminated Beam Glulam 24F-V4 DF/DF Glued Laminated Beam TimberStrand LSL 1.55E Parallam PSL 2.0E Microllam LVL 1.9E Wood Post Axial Loads Capacity: POST HEIGHT (FT) Post 7 8 9 10 12 14 18.67 22 2x4 DFL STANDARD 3.29 2.64 2.14 1.76 1.25 0.93 --- --- 2x4 DFL STUD 2.89 2.42 2.01 1.69 1.22 0.91 ------ 4x4 DFL No.2 8.73 7.00 5.69 4.69 3.33 2.48 --- --- 2x6 DFL STUD 5.16 5.16 5.16 4.93 4.00 3.18 1.94 1.43 2x6 DFL No.2 5.16 5.16 5.16 5.16 5.06 3.88 2.28 1.67 4x6 DFL No.2 13.58 10.93 8.90 7.35 5.22 3.89 --- --- 4x8 DFL No.2 17.71 14.30 11.67 9.66 6.87 5.12 --- --- 4x10 DFL No.2 22.32 18.10 14.81 12.27 8.74 6.52 ------ 4x12 DFL No.2 27.15 22.01 18.01 14.92 10.63 7.93 --- --- 6x6 DFL No.1 26.37 24.84 23.01 20.99 16.90 13.42 8.15 6.00 6x8 DFL No 1 35.96 33.87 31.38 28.62 23.05 18.30 11.11 8.19 8x8 DFL No.1 52.82 51.56 50.01 48.16 43.51 37.99 25.86 19.67 Fb Fv E 900 900 180 1.6 E 180 1.6 E 1350 170 1.6 E 265 1.8 E2400/1850 2.0 E 1.9 E 1.55 E2350 2900 2600 310 285 285 2201 W Seventh St 12/9/2024 BEAM DESIGN Job Number : Plan : ID: E1 Rigde bm over Living room @ Length of Span (ft):15.75 (ft)Reaction (lbs) Roof 21.00 0 15.75 P1 0.00 0 0 0 Left 3103 None 0 0 0.00 P2 0.00 0 0 0 Right 3103 None 0 0 0.00 Self Weight ID: E2 Hip bm over Kitchen @ Length of Span (ft):15.00 (ft)Reaction (lbs) Roof 14.00 0 15.00 P1 0.00 0 0 0 Left 2010 None 0 0 0.00 P1 0.00 0 0 0 Right 2010 None 0 0 0.00 Self Weight ID: E3 Cl'g bm right of Kitchen MEMBER SIZE : @ Length of Span (ft):13.50 (ft)Reaction (lbs) Ceil.2.67 0 13.50 P1 3.00 4009 4454 0 Left 6834 None 0 0 0.00 P2 0.00 0 0 0 Right 2133 None 0 0 0.00 Self Weight DL (Ibs) Lr (Ibs) L (Ibs) 2.67*(6+10)/2 0 0 16.00 Uni. Load Span (ft) Unit Load (plf) Start (ft) End (ft) Point Load Lr (Ibs) L (Ibs) 14*(16+20)/2 0 0 16.00 Uni. Load Span (ft) Unit Load (plf) Start (ft) End (ft) Point Load DL (Ibs) 24058 DL (Ibs) Lr (Ibs) L (Ibs) 21*(16+20)/2 0 0 16.00 Uni. Load Span (ft) Unit Load (plf) Start (ft) End (ft) Point Load 2201 W Seventh St 12/9/2024 BEAM DESIGN Job Number : Plan : ID: 1 Cl'g bm over Kitchen MEMBER SIZE : @ Length of Span (ft):18.75 (ft)Reaction (lbs) Ceil.21.00 0 18.75 P1 8.00 3280 3554 0 Left 5831 None 0 0 0.00 P2 0.00 0 0 0 Right 4828 None 0 0 0.00 Self Weight None 0 0 0.00 Adjustment Factors: CD CM Ct CL CF Cfu Ci Cr Cv Design Summary :1.25 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.94 Design Results Value Loc(ft) Allowed Ratio Section Properties & Allowable Stresses : Max. Moment(Ft-lbs)35604 8.00 60577 0.59 b(in) 10.75 E'min(ksi)930000 E/Ex(psi)1.94 F*b(psi)2160 Max. Shear(lbs)4846.5 28488 0.17 d(in) 12 FbE(psi)25960 Fb(psi)2400 F'b(psi)1850 Live Load Defl.(in)0.435 9.1 0.536 0.81 A(in2)129 I (in4)1548.0 Fv(psi)265 F'v(psi)265 Total Load Defl.(in)0.664 9.0 0.938 0.71 S(in3)258 RB 6.6 E'(ksi) 1800000 ID: 2 Cl'g bm over Kitchen MEMBER SIZE : @ Length of Span (ft):2.50 (ft)Reaction (lbs) Ceil.21.00 0 2.50 P1 0.00 0 0 0 Left 219 None 0 0 0.00 P1 0.00 0 0 0 Right 219 None 0 0 0.00 Self Weight None 0 0 0.00 Adjustment Factors: CD CM Ct CL CF Cfu Ci Cr Cv Design Summary :0.90 1.00 1.00 1.00 1.30 1.00 1.00 1.00 1.00 Design Results Value Loc(ft) Allowed Ratio Section Properties & Allowable Stresses : Max. Moment(Ft-lbs) 54.688 1.25 2691 0.02 b(in) 3.5 E'min(ksi)580000 E/Ex(psi)2.76 F*b(psi)810 Max. Shear(lbs) 87.5 2741 0.03 d(in) 7.25 FbE(psi)19029 Fb(psi)900 F'b(psi)900 Live Load Defl.(in) 0.001 1.3 0.167 0.00 A(in2)25.38 I (in4)111.1 Fv(psi)180 F'v(psi)180 Total Load Defl.(in) 0.000 1.3 0.125 0.00 S(in3)30.66 RB 6.0 E'(ksi) 1600000 0 Lr (Ibs) L (Ibs) 21*(6+10)/2 0 0 7.00 DFL 4 x 8 Uni. Load Span (ft) Unit Load (plf) Start (ft) End (ft) Point Load DL (Ibs) 24058 0 DL (Ibs) Lr (Ibs) L (Ibs) 21*(6+10)/2 0 0 36.00 GLB 24F V4 GLB 10 3/4 x 12 Uni. Load Span (ft) Unit Load (plf) Start (ft) End (ft) Point Load 2201 W Seventh St 12/9/2024 SHEARWALL DESGIN GENERAL (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code)Job Number :24058 Plan : GENERAL MATERIALS Code : AF&PA NDS-2018 &SDPWS-2021(ASD) Descript. Material Size Design Method : Segment & FTAO Top Plate DF/SPine Load Combo : 2021 IBC/2022 CBC & ASCE 7-16 Sill Plate DF/SPine HD Manufacturer : SIMPSON Wall Stud DF/SPine Panel Schedule : 2022 CBC Chord DF/SPine 2X4 Min. 2022 CBC 16d's Sinker SDS Screws(*) 1 260 6" O.C. 16" O.C. 24" O.C. 2 380 4" O.C. 12" O.C. 16" O.C. 3 490 3" O.C. 8" O.C. 12" O.C. 4 640 2" O.C. 6" O.C. 10" O.C. 5 800 (2) 3" O.C. 5" O.C. 6" O.C. 3(D.S.)1020 (2) 3" O.C. 4" O.C. N/A 4(D.S.)1330 (2) 3" O.C. 3" O.C. N/A 5(D.S.)1740 (2) 3" O.C. 2.5" O.C. N/A Notes: -(*) Use 1/4"dia. x6"SDS Screws DRAG TYPE FORCE SCHEDULE Type A B C D E F FORMULAS MAXIMUM SHEAR WALL DEFLECTION: ( IBC Section 2305.3 / SDPWS-08 4.3.2) -Provide 3" Nominal Or Wider Framing At Adjoining Panel Edges With Nails Staggered. -Use Clips @ 6" O.C. On Simpson Strong Wall & Hardy Frame (U.N.O.). -Use Spacing Per Schedule If Number Of Framing Clips Are Not Specified On Framing Plans. -Sheathing Conforms to Either Doc PS 1 Or PS 2 Standards. 8d's @ 2" O.C. 10d's @ 2" O.C. 10d's @ 2" O.C. -Sheathing Panel Joint And Sill Plate Nailing Shall Be Staggered In All Cases. Panel Type Edge Nail (common) Field Nail (common) 3/8" 3/8" 3/8" 15/32" 10d's @ 4" O.C. 10d's @ 3" O.C. 10d's @ 12" O.C. 10d's @ 12" O.C. 10d's @ 12" O.C. 15/32" Sill Plate Connection Framing(2) Clips SHEAR WALL SCHEDULE of 10d's @ 12" O.C. 15/32" Allowable Shear(plf)Sheathing (Plywood/OSB) 3/8" 15/32" 8d's @ 6" O.C. 8d's @ 4" O.C. 8d's @ 3" O.C. 8d's @ 12" O.C. 8d's @ 12" O.C. 8d's @ 12" O.C. 8d's @ 12" O.C. Simpson MSTC52 or ALT.(36)16d sinker per top plate splice 1192 2134 3230 4267 4745 5653 Simpson ST22 or ALT.(10)16d sinker per top plate splice Simpson ST6224 or ALT.(16)16d sinker per top plate splice Simpson ST6236 or ALT.(22)16d sinker per top plate splice Simpson MST37 or ALT.(24)16d sinker per top plate splice Top Plate Splice Simpson MST48 or ALT.(32)16d sinker per top plate splice -(2) Clips Framing Use A35's, LS50's or LTP4's. -Periodic Special Inspection is Required. -Use Spacing Per Schedule If Number Of Framing Clips Are Not Specified On Framing Plans. -For Holdown Attached To Inside Face Of End Post. Load Capacity 38 0.75b b a Bending Shear Nail slip Chord splice slip n w w h hv h v dheEA GtL L D = + + + = + + +D D D D 38 0.75b b a Bending Shear Nail slip Chord splice slip n w w h hv h v dheEA GtL L D = + + + = + + +D D D D 38 0.75b b a Bending Shear Nail slip Chord splice slip n w w h hv h v dheEA GtL L D = + + + = + + +D D D D 38 0.75b b a Bending Shear Nail slip Chord splice slip n w w h hv h v dheEA GtL L D = + + + = + + +D D D D 2201 W Seventh St 12/9/2024 N N N N LIVING ROOM KITCHEN CLOSET CLOSET CLOSET CLOSET BEDROOM BEDROOM BEDROOM BATHROOM GARAGE RELOCATED WINDOW Job Number : 24058LATERAL SHEAR WALL LAYOUT Plan : ROOF SHEAR WALL LAYOUT SECTION 1 A SECTION 2 B 2201 W Seventh St 12/9/2024 LATERAL ANALYTICAL SECTION (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code)Job Number : 24058 1 Plan : GENERAL INPUT : (1 STORY) Base Height Above Ground (ft)0.50 Plate Height (ft)8.00 South Roof Height (N-S Direction-ft)11.50 West Roof Height (E-W Direction-ft)11.50 South Roof Type (N-S Direction) Slope West Roof Type (E-W Direction) Slope Roof Depth (N-S-ft)23.25 Roof Depth (E-W-ft)39 Diaphragm Depth (N-S Direction-ft)21.5 Diaphragm Depth (E-W Direction-ft)37 Diaphragm Span (N-S Direction-ft)37 Diaphragm Span(E-W Direction-ft)21.5 Number of Ext. Wall (N-S)2 Number of Ext. Wall (E-W)2 Number of Int. Wall (N-S)1 Number of Int. Wall (E-W)2 SEISMIC ANALYSIS :(Using Equivalent Force Procedure per ASCE 7-16) Determine Section Weight : For N-S Direction : Area(ft^2) Unit Roof 906.75 16 Ext.Wall(ft.)296 15 Int. Wall(ft)148 10 Sum:20,428 Ev(ASD) Base Shear :(V=Cs*W) :2,298.5 4269 lbs 2.53 58.8225 For E-W Direction : Area(ft^2) Unit Roof 906.75 16 Ext.Wall(ft.)172 15 Int. Wall(ft)172 10 Sum:18,808 Ev(ASD) Base Shear :(V=Cs*W) :2,116.2 3930 lbs 2.33 90.9 WIND ANALYSIS :(MWFRS Directional Procedure Chapter 27 Part1 per ASCE 7-16 for Building of any Height) The Velocity Pressures : qz = 0.00256 Kz Kzt Kd V2 (ASCE 7-16 Equation27.3-1) Kzt = 1.0 (Flat Terrian) Kd = 0.85 (ASCE 7-16 Table 26.6-1) Kz = 2.01*(max(z,15)/zg)(2/a)( ASCE 7-16 Tables 27.3-1) h(ft)kz qz(psf) Roof 10.33 0.849 22.35 Wall 8.00 0.849 22.35 p=qz*G*Cp-qi*(+/-GCpi) for windward wall (psf), where : qi=qh(Eq. 27.3-1, Sect.27.3.2) p=qh*G*Cp-qi*(+/-GCpi) for leeward wall, side wall & roof (psf), where : qi=qh( Eq. 27.3-1, Sect.27.3.2) The Internal Pressures: Gcpi(+/-) 0.18 qh 22.35 psf +qhGCpi 4.02 psf -qhGCpi -4.02 psf (see next page for details) SECTION NUMBER : Weight(Ib) 14508 4440 1480 Unit FN-S(psf) Unit FN-S(plf) Weight(Ib) 14508 2580 1720 Unit FE-W(psf) Unit FE-W(plf) 2201 W Seventh St 12/9/2024 LATERAL ANALYTICAL SECTION (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) Job Number : 24058 SECTION NUMBER : 1 (cont.)Plan : Normal to Ridge Wind Load Tabulation for MWFRS with q ≥ 10o(N-S Direction): (w/+Gcpi) (w/-Gcpi) All 0.80 22.35 19.22 11.18 Cond.1 -0.36 22.35 -2.87 -10.91 Cond.2 0.14 22.35 6.63 -1.41 All -0.57 22.35 -6.78 -14.82 All -0.40 22.35 -3.66 -11.70 All -0.70 22.35 -9.28 -17.32 Design Sumary Wind Loading (N-S Direction): Horizontal Vertical Roof 12.72 4.69 1st Floor 22.88 0.00 136.05 plf Parallel to Ridge Wind Load Tabulation for MWFRS (E-W Direction): (w/+Gcpi) (w/-Gcpi) Roof 0.80 22.35 19.22 11.18 Wall 0.80 22.35 19.22 11.18 Cond.1 -0.90 22.35 -13.08 -21.12 Cond.2 -0.18 22.35 0.60 -7.44 Cond.1 -0.90 22.35 -13.08 -21.12 Cond.2 -0.18 22.35 0.60 -7.44 Cond.1 -0.50 22.35 -5.48 -13.52 Cond.2 -0.18 22.35 0.60 -7.44 Cond.1 -0.30 22.35 -1.68 -9.72 Cond.2 -0.18 22.35 0.60 -7.44 All -0.50 22.35 -5.48 -13.52 All -0.70 22.35 -9.28 -17.32 Design Sumary Wind Loading (E-W Direction): Horizontal Vertical Roof 24.70 6.68 Wall 24.70 0.00 185.25 plf DIAPHRAGMS ANALYSIS (ASD METHOD) : Design Sumary Loading : Seis.(N-S)Wind(N-S)Govern Seis.(E-W)Wind (E-W)Govern Roof 58.8 81.6 Wind 90.9 111.2 Wind For N-S Direction : Max. Diaphragm Shear @ Roof : Vn-s=wL/2B 49.36 plf < 180 plf OK USE : 15/32" APA(OR OSB) RATED SHEATHING EXP 1 WITH A MIN. PANEL INDEX OF 32/16. UNBOCKLED DIAPHRAGMS W/8d @ COMMON NAIL @ 6" O.C. B.N., 6" O.C. E.N., 12' O.C F.N. CHORD FORCE :85.51 SPICE W/ MINI (5)16d SINKER EACH SIDE OF SPLICE @ 8" O.C.(STANDARD CONSTRUCTIONS) For E-W Direction : Max. Diaphragm Shear @ Roof : Ve-w=wL/2B 34.92 plf < 180 plf OK USE : 15/32" APA(OR OSB) RATED SHEATHING EXP 1 WITH A MIN. PANEL INDEX OF 32/16. UNBOCKLED DIAPHRAGMS W/8d @ COMMON NAIL @ 6" O.C. B.N., 6" O.C. E.N., 12' O.C F.N. CHORD FORCE :308.82 SPICE W/ MINI (5)16d SINKER EACH SIDE OF SPLICE @ 8" O.C.(STANDARD CONSTRUCTIONS) Surface Location Cp q(psf)qGCp(psf)Net Pressure (psf) Windward Wall 15.20 Windward Roof -6.89 2.61 Leeward Roof -10.80 Leeward Wall -7.68 Side Walls -13.30 Location Net Pressure (psf) Surface Location Cp q(psf)qGCp(psf)Net Pressure (psf) Windward Wall 15.20 15.20 Leeward Wall -9.50 Side Walls -13.30 Location Net Pressure (psf) Windward Roof 0 to h/2 -17.10 -3.42 h/2 to h -17.10 -3.42 h to 2h -9.50 -3.42 >2h -5.70 -3.42 2201 W Seventh St 12/9/2024 LATERAL ANALYTICAL SECTION (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code)Job Number : 24058 2 Plan : GENERAL INPUT : (1 STORY) Base Height Above Ground (ft)0.50 Plate Height (ft)8.00 South Roof Height (N-S Direction-ft)11.50 West Roof Height (E-W Direction-ft)11.50 South Roof Type (N-S Direction) Gable West Roof Type (E-W Direction) Slope Roof Depth (N-S-ft)14 Roof Depth (E-W-ft)19.25 Diaphragm Depth (N-S Direction-ft)13 Diaphragm Depth (E-W Direction-ft)17.25 Diaphragm Span (N-S Direction-ft)17.25 Diaphragm Span(E-W Direction-ft)13 Number of Ext. Wall (N-S)1 Number of Ext. Wall (E-W)2 Number of Int. Wall (N-S)1 Number of Int. Wall (E-W)1 SEISMIC ANALYSIS :(Using Equivalent Force Procedure per ASCE 7-16) Determine Section Weight : For N-S Direction : Area(ft^2) Unit Roof 269.5 16 Ext.Wall(ft.)69 15 Int. Wall(ft)69 10 Sum:6,037 Ev(ASD) Base Shear :(V=Cs*W) :679.3 1261 lbs 2.52 35.28 For E-W Direction : Area(ft^2) Unit Roof 269.5 16 Ext.Wall(ft.)104 15 Int. Wall(ft)52 10 Sum:6,392 Ev(ASD) Base Shear :(V=Cs*W) :719.2 1336 lbs 2.67 51.4 WIND ANALYSIS :(MWFRS Directional Procedure Chapter 27 Part1 per ASCE 7-16 for Building of any Height) The Velocity Pressures : qz = 0.00256 Kz Kzt Kd V2 (ASCE 7-16 Equation27.3-1) Kzt = 1.0 (Flat Terrian) Kd = 0.85 (ASCE 7-16 Table 26.6-1) Kz = 2.01*(max(z,15)/zg)(2/a)( ASCE 7-16 Tables 27.3-1) h(ft)kz qz(psf) Roof 10.33 0.849 22.35 Wall 8.00 0.849 22.35 p=qz*G*Cp-qi*(+/-GCpi) for windward wall (psf), where : qi=qh(Eq. 27.3-1, Sect.27.3.2) p=qh*G*Cp-qi*(+/-GCpi) for leeward wall, side wall & roof (psf), where : qi=qh( Eq. 27.3-1, Sect.27.3.2) The Internal Pressures: Gcpi(+/-) 0.18 qh 22.35 psf +qhGCpi 4.02 psf -qhGCpi -4.02 psf (see next page for details) SECTION NUMBER : Weight(Ib) 4312 1035 Weight(Ib) 4312 1560 690 Unit FN-S(psf) Unit FN-S(plf) 520 Unit FE-W(psf) Unit FE-W(plf) 2201 W Seventh St 12/9/2024 LATERAL ANALYTICAL SECTION (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) Job Number : 24058 SECTION NUMBER : 2 (cont.)Plan : Parallel to Ridge Wind Load Tabulation for MWFRS (E-W Direction): (w/+Gcpi) (w/-Gcpi) All 0.80 22.35 19.22 11.18 Cond.1 -0.36 22.35 -2.87 -10.91 Cond.2 0.14 22.35 6.63 -1.41 All -0.57 22.35 -6.78 -14.82 All -0.50 22.35 -5.48 -13.52 All -0.70 22.35 -9.28 -17.32 Design Sumary Wind Loading (E-W Direction): Horizontal Vertical Roof 12.72 4.69 1st Floor 24.70 0.00 143.33 plf Normal to Ridge Wind Load Tabulation for MWFRS with q ≥ 10o(N-S Direction): (w/+Gcpi) (w/-Gcpi) Roof 0.80 22.35 19.22 11.18 Wall 0.80 22.35 19.22 11.18 Cond.1 -0.90 22.35 -13.08 -21.12 Cond.2 -0.18 22.35 0.60 -7.44 Cond.1 -0.90 22.35 -13.08 -21.12 Cond.2 -0.18 22.35 0.60 -7.44 Cond.1 -0.50 22.35 -5.48 -13.52 Cond.2 -0.18 22.35 0.60 -7.44 Cond.1 N/A N/A N/A N/A Cond.2 N/A N/A N/A N/A All -0.40 22.35 -3.66 -11.70 All -0.70 22.35 -9.28 -17.32 Design Sumary Wind Loading (N-S Direction): Horizontal Vertical Roof 22.88 6.68 Wall 22.88 0.00 171.60 plf DIAPHRAGMS ANALYSIS (ASD METHOD) : Design Sumary Loading : Seis.(N-S)Wind(N-S)Govern Seis.(E-W)Wind (E-W)Govern Roof 35.3 103.0 Wind 51.4 86.0 Wind For N-S Direction : Max. Diaphragm Shear @ Roof : Vn-s=wL/2B 50.82 plf < 180 plf OK USE : 15/32" APA(OR OSB) RATED SHEATHING EXP 1 WITH A MIN. PANEL INDEX OF 32/16. UNBOCKLED DIAPHRAGMS W/8d @ COMMON NAIL @ 6" O.C. B.N., 6" O.C. E.N., 12' O.C F.N. CHORD FORCE :64.68 SPICE W/ MINI (5)16d SINKER EACH SIDE OF SPLICE @ 8" O.C.(STANDARD CONSTRUCTIONS) For E-W Direction : Max. Diaphragm Shear @ Roof : Ve-w=wL/2B 34.90 plf < 180 plf OK USE : 15/32" APA(OR OSB) RATED SHEATHING EXP 1 WITH A MIN. PANEL INDEX OF 32/16. UNBOCKLED DIAPHRAGMS W/8d @ COMMON NAIL @ 6" O.C. B.N., 6" O.C. E.N., 12' O.C F.N. CHORD FORCE :124.34 SPICE W/ MINI (5)16d SINKER EACH SIDE OF SPLICE @ 8" O.C.(STANDARD CONSTRUCTIONS) Windward Wall 15.20 Windward Roof -6.89 2.61 Surface Location Cp q(psf)qGCp(psf)Net Pressure (psf) Location Net Pressure (psf) Surface Location Cp q(psf) Leeward Roof -10.80 Leeward Wall -9.50 Side Walls -13.30 qGCp(psf)Net Pressure (psf) Windward Wall 15.20 15.20 Windward Roof 0 to h/2 -17.10 -3.42 h/2 to h Leeward Wall -7.68 Side Walls -13.30 Location Net Pressure (psf) -17.10 -3.42 h to 2h -9.50 -3.42 >2h N/A N/A 2201 W Seventh St 12/9/2024 JOB NUMBER : 24058 PLAN: Story 1 Line :A Redundancy(ρ)1.3 X Dir. Lateral loads : at A Max. Drag Force : 517 lb Use Drag Type A (See Shear wall Schedule) Total Wall Length : 17.00 ft Total Panel Length : 4.00 ft Net Length : 4.00 ft Shear Diaphragm : 43 plf Design Wall Shear : 183 plf Use ( 2 A35) or (2 LS50) Along Line Shear Panel or for Framing Clips Spacing See S.W. Schedule USE TYPE 2 ok Ratio Shear : 0.48 Max. Panel Deflection :0.959 " < 1.92 "ok Holdown & Deflection Check A 4.00 4.00 8 1520 1665 1520 1665 4X4 4X4 2 32" Uplift Above 00 lbs Span(ft) Seis. (lbs) Wind (lbs) From Line 1 Lateral Loads: 0% 0 0 Post size Panel Length (ft) Net L (ft) Height (ft) Left Seis. Wall (lbs)137 Down (lb) 2X_ROOF 13 17.25 595 507 Sum :732 507 Right Span (ft) Deep (ft) Wind (lbs)Seis. (lbs) (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) SHEAR WALL DESIGN Deflection (in.)A.B.Spacing (in.) HDU2 HDU2 0.1712 Holdown L. R.Uplift (lb) Down (lb)Holdown Uplift (lb) DM = (4.0/1.0) X Ds X 1.4 = 0 5 8 1717171717171717 1 50000000000 A 2201 W Seventh St 12/9/2024 JOB NUMBER : 24058 PLAN: Story 1 Line :B Redundancy(ρ)1.3 X Dir. Lateral loads : at A Max. Drag Force : 1769 lb Use Drag Type B (See Shear wall Schedule) Total Wall Length : 36.50 ft Total Panel Length : 6.25 ft Net Length : 6.25 ft Shear Diaphragm : 58 plf Design Wall Shear : 342 plf Use ( 5 A35) or (4 LS50) Along Line Shear Panel or for Framing Clips Spacing See S.W. Schedule USE TYPE 2 ok Ratio Shear : 0.90 Max. Panel Deflection :1.428 " < 1.92 "ok Holdown & Deflection Check A 6.25 6.25 8 2759 2951 2759 2951 4X4 4X4 3 32" Holdown L. R.Uplift (lb) Down (lb)Holdown Uplift (lb) Span (ft) Deep (ft) Wind (lbs)Seis. (lbs) (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) SHEAR WALL DESIGN Deflection (in.)A.B.Spacing (in.) HDU2 HDU2 0.2551 21.5 37 1437 1195 559 Sum :2135 1754 Right 1X_ROOF 2X_ROOF 13 17.25 455 Post size Panel Length (ft) Net L (ft) Height (ft) Left Seis. Wall (lbs)243 Down (lb) Span(ft) Seis. (lbs) Wind (lbs) From Line 1 Lateral Loads: 0% 0 0 From Line 100% 0 0 Uplift Above 00 lbs DM = (4.0/1.0) X Ds X 1.4 = 0 5.25 15 21 23.5 26.25 30.25 36.536.536.536.5 30.25 36.50000000000 A 2201 W Seventh St 12/9/2024 FOOTING & PAD DESIGN (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) Job Number : 24058 Plan : ID: P1 Pad support 1-Beam #1 (Design Footing & Pad on Footing) Loading :Design : Load Type Span(ft) Unit Loads(plf) Total Weight :plf I.Wall 8.00 8*10 Total Point Load : lbs None 0 0 Footing With Required : in. None 0 0 None 0 0 Capacity of Point Load on Footing:lbs Self Weight 225 Allowable Point Load on Footing : lbs Required Pad Width :in. Use 2.5' SQ x 24 in. Deep w/(3)#4 @ Bott. E.W. for Pad ID: P2 Pad support 2-Beam #1 (Design Footing & Pad on Footing) Loading :Design : Load Type Span(ft) Unit Loads(plf) Total Weight :plf I.Wall 9.00 9*10 Total Point Load : lbs None 0 0 Footing With Required : in. None 0 0 None 0 0 Capacity of Point Load on Footing:lbs Self Weight 225 Allowable Point Load on Footing : lbs Required Pad Width :in. Use 2' SQ x 24 in. Deep w/(3)#4 @ Bott. E.W. for Pad 305 6000 2.5 1.81 5000 3983 2 315 4900 2.6 5000 3950 2201 W Seventh St 12/9/2024 ASCE Hazards Report Address: 2201 W 7th St Santa Ana, California 92703 Standard:ASCE/SEI 7-16 Latitude:33.750758 Risk Category:II Longitude:-117.900887 Soil Class:D - Default (see Section 11.4.3) Elevation:87.12810760109149 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Thu Jul 11 2024 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. https://ascehazardtool.org/Thu Jul 11 2024 2201 W Seventh St 12/9/2024 SS : 1.306 S1 : 0.465 F a : 1.2 F v : N/A SMS : 1.568 SM1 : N/A SDS : 1.045 SD1 : N/A T L : 8 PGA : 0.555 PGA M : 0.666 F PGA : 1.2 Ie : 1 C v : 1.361 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Thu Jul 11 2024 https://ascehazardtool.org/Thu Jul 11 2024 2201 W Seventh St 12/9/2024 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. https://ascehazardtool.org/Thu Jul 11 2024 2201 W Seventh St 12/9/2024