222 S Spruce St - Plan
PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. OWNER SCOPE PROJECT ADDRESS PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX PHOTOVOLTAIC NOTES SATELLITE VIEW BUILDING INFORMATION: ELECTRICAL INFORMATION MAIN SERVICE PANEL BUSBAR RATING MAIN SERVICE BREAKER RATING 1ɸ, 3W, 120/240V RACKING INFORMATION Main Service Panel Solar Module Micro Inverter / Optimizer EMT / FMT / PVC / RMC type conduit/ Romex NM Cable/ FNMT (Fluid non-metalic tube) 36'' SetbackInverter Utility Meter Production Meter PV Load Center IQ Combiner Box Junction Box Sunpower PV Supervisor 18'' Setback EV Outlet CONSTRUCTION TYPE: V-B ROOF TYPE AHJ APN LOT AREA LIVING AREA MSP UM PM INV PV PVS6 IQ J/B EV ROSENDO TORRES 12 1 SOLAR EDGE ENERGY HUB SE6000H-US (240V) SOLAREDGE BAT-10K1PS0B-01 ENERGY BANK 10KWH 222 S SPRUCE ST, SANTA ANA, CA 92703 SSP Service Sub Panel COMPOSITION SHINGLE 1,785 SQFT 00732115 CITY OF SANTA ANA ROOF MOUNT INSTALLATION OF DC PHOTOVOLTAIC SYSTEM 4.74 KW DC 4.74 KW 4.42 KW AC NEW UPGRADED ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA HISTORICAL CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA REFERENCED STANDARDS CODE 2022 CALIFORNIA ADMINISTRATIVE STANDARDS CODE 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8 .INVERTER IS EQUIPPED W/ INTEGRATED GFCI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 12. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER CEC 250.122 13. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 14. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS 6,741 SQFT Battery BackupBB Auto TransformerAT Solar Edge Meter EnclosureSEM Distribution PanelDP Rapid Shutdown ControllerRSC Rapid Shutdown BoxRSB Itron MeterIM UNIT INDEX CODE REFERENCES IRONRIDGE RACKING RAFTERS 2"X6" @ 16" O.C OCCUPANCY: R ONE STORY BUILDING 200A 200A CANADIAN SOLAR 395W CS6R-395MS-HL (don't delete this note) AC DisconnectACD Visible Lockable Labeled DisconnectVLLD 1 0 0 TITLE SHEET SINGLE LINE DIAGRAM CODE REQUIRED SIGNAGE E 1.1 PV 2.0 ATTACHMENT LAYOUTS 1.0 PV 2.1 PV 3.0 INVERTER DATA SHEET MODULE DATA SHEET RACKING SPECIFICATIONS ATTACHMENT SPECIFICATIONS ROOF PLAN MODULE MAP WIRE SIZE CALCULATIONS INVERTER MAP GROUNDING SPECIFICATIONS OPTIMIZER DATA SHEET PV 0.0 E 1.0 SITE PLANPV 1.0 PV 3.1 PV 4.0 PV 4.1 PV 5.0 PV 5.1 PV 6.0 PV 6.1 BATTERY DATA SHEET TITLE SHEET Bldg# 1011205572 Elec# 20183818 Approvals: Elec: MSmith The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW ROOF AREA CALCULATIONS FIRE SPRINKLERS - NO TOTAL ROOF AREA (SQ.FT.) - 3085 SOLAR AREA (SQ.FT.) - 252 % OF COVERED AREA - 8.2% PHOTOVOLTAIC SYSTEM 1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-US (240V) Solar Edge S440 Power Optimizers12 FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT4.74 KW DC 12 Canadian Solar 395W Modules (CS6R-395MS-HL) ROOF PLAN 36'' Setback 18'' Setback PV 0.0 N 0° S 180° E 90° W 270° SCALE 1" = 10' MSP ACD INV SolarEdge Energy Bank Battery Gate Gate J/B S S P R U C E S T Solar Array 2 9 Canadian 395W Modules 9 S440 Optimizers Tilt: 9 Deg Azimuth: 180 Deg Solar Array 1 3 Canadian 395W Modules 3 S440 Optimizers Tilt: 9 Deg Azimuth: 180 Deg 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW SITE PLAN PV 1.0 N 0° S 180° E 90° W 270° SCALE 1" = 15' MSP INV ACD Driveway Pu b l i c S i d e w a l k S S P R U C E S T S S P R U C E S T SolarEdge Energy Bank Battery Gate Gate 110' 65' 16' 43' 36' 7' PROPERTY LINE (E) MAIN HOUSE 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW STRUCTURAL STAMPROOF PITCH ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE FRAMING SIZE PENETRATION PATTERN 9° RACKING TYPE MAX PENETRATION SPACING ROOFING LAYERS WIND SPEED 95 MPH SNOW LOAD 0 PSF EXPOSURE C LAG BOLTS MOUNTS AND MOUNTING HARDWARE WILL BE SEALED WITH CHEM LINK SEALANT OR EQUIVALENT. MODULE WEIGHT (LBS) # OF MODULES TOTAL MODULE WEIGHT (LBS) RACK WEIGHT (LBS) TOTAL SYSTEM WEIGHT (LBS) # OF STANDOFFS LOADING PER STANDOFF (LBS) TOTAL MODULE AREA (SQ.FT.) LOADING (PSF) WEIGHT LOAD CALCULATION INDEX ROOF SHEATHED WITH 1/2" PLYWOOD AND UPPER SURFACE IS FACED WITH FELT PAPER TOTAL ROOF AREA (Sq. FT) % OF COVERED AREA PV MODULE MODEL # OPTIMIZERS WEIGHT (LBS) 12 Roof 1 Layer Comp Shingle Ironridge XR10 Rafter Stacked 48"2"X6" @ 16" O.C 3 1 2 4 ITEM NO. 1 DESCRIPTION 2 3 4 BOLT LAG 5/16 X 4.75" ASSY, FLASHING ASSY, CAPFOOT WASHER, EPDM BACKED Qty in Kit 4 4 4 4 5/16" X 4.75" Flash Foot 2 MIN 2.5" EMBEDMENT RACKING RAIL ATTACHMENT ROOF FRAMING 30 252 3085 593 119 18 729 24.3 2.89 8.2 2''X6'' Blocking 2''X4'' Support 2''X4'' Purlin 2''X6'' Collar Tie SOLAR MODULE ROOF ASCE 7-16 Max 3.5'' 49.4 CS6R-395MS-HL ATTACHMENT LAYOUT S 1.0 48"16" 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW ITEM DESCRIPTION QTY# PV MODULE MAIN SERVICE PANEL MAIN SERVICE PANEL & UTILITY METER BUSBAR RATING BREAKER RATING 1 ITEM DESCRIPTION QTY# PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3 1 1 1 4 3 1 4 6 MAIN SERVICE PANEL 120/240V 1P,3W 2 EXISTING GROUNDING SYSTEM UTILITY 2 3 5700W INVERTER PEAK PWR TRACKING VOLTAGE INVERTER EFFICIENCY ENCLOSURE : MAXIMUM INPUT CURRENT MAXIMUM OUTPUT CURRENT MAXIMUM INPUT POWER MAXIMUM OUTPUT POWER 4 1 380 V 99 % NEMA 3R 16.5 A 25.0 A 12,000 W 6,000 W SOLAREDGE ENERGY HUB SE6000H-US (240V) SOLAREDGE POWER OPTIMIZER RATED DC INPUT POWER MAXIMUM INPUT VOLTAGE MPPT RANGE MAXIMUM SHORT CIRCUIT CURRENT (Isc) MAXIMUM OUTPUT CURRENT OPTIMIZER WEIGHT MAXIMUM POWER PER STRING 5 S440 440W 60 Vdc 8 to 60 Vdc 14.5 Adc 15 Adc 1.5 Lbs 12POWER OPTIMIZER 60AAC DISCONNECT NON FUSED AC DISCONNECT LOCKABLE, BLADE TYPE, NEMA 3R, 120/240V 16 NEW UPGRADED NEW 2 1 33 200A 200A 200A FOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3 INSTALL 2P 40A CB(PV) AT OPPOSITE END OF BUS FROM MAIN FEEDER CB 12 Canadian Solar 395W CS6R-395MS-HL Voc = 36.6V Vmp = 30.6V Isc = 13.77A Imp = 12.91A (N)200A String: (12) Modules, (12) Optimizers SINGLE LINE DIAGRAM 7 (2)#10 AWG (10-12 AWG), 600V insulated (1)#24 AWG (16-24 AWG), 600V insulated or CAT6 1" EMT TYPE Conduit BATTERY BACKUP BATTERY BACKUP SYSTEMS SOLAR EDGE ENERGY BANK 10kWh, BAT-10K1P 17 E 1.0 222 S Spruce St 9/12/2024 FROM PV MODULES TO JBOX FROM JBOX TO INVERTER (2)1 (1) #6 AWG BARE CU EGC, 2 #8 AWG CU EGC, (3) 3 (1) #8 AWG CU EGC, MAXIMUM INVERTER OUTPUT CURRENT (A) TEMPERATURE FACTOR TEMPERATURE ADJUSTMENT (A) OUTPUT CALCULATIONS PV SYSTEM MAX DC OUTPUT PV SYSTEM MAX AC OUTPUT MAXIMUM POWER (W) PEAK PWR TRACKING VOLTAGE (V) CONSIDER CONTINUOUS COEFFICIENT SHORT CIRCUIT CURRENT (A) ADJUSTED CONDUCTOR AMPACITY (A) 1.25 1.25 1.25 0.91 (2) (1) Pmax (PTC Rating) 25.0 380 1 99 % 25.0 * 1.25 / 0.91 34.4 #8 AWG THWN-2 40A SOLAR EDGE SE6000H-US (240V) 25.0 * 1.25 31.3 1 1/2'' (TEMP - 39 + 22 = 61C)0.58 RACEWAY HEIGHT FROM ROOF ADJST. FACTOR (1 thru 3 WIRES)1.0 FREE IN THE AIR, 3/4'' EMT TYPE CONDUIT BETWEEN ARRAYS 3/4'' EMT TYPE CONDUIT 1'' EMT TYPE CONDUIT MAIN SERVICE PANEL RATING BUSBAR RATING MAIN BREAKER PV BACKFEED BREAKER SIZE 120% RULE: MAX ALLOWED FEED 40A */*1.25 *1.2512 395 380 19.5 / /19.5 0.58 1.0 33.6 #10 AWG THWN-2 WIRE CHART WIRE CHART *12 395 4.74 KW * *12 371.9 0.99 4.42 KW CONSIDER CONTINUOUS COEFFICIENT CONSIDER CONTINUOUS COEFFICIENT 200A 200A 240A 200A ''MB'' + 40A "SOLAR" = 240A ≤ 240A MAX FROM INVERTER TO MAIN SERVICE PANEL CONSIDER CONTINUOUS (A) MAX NUMBER OF MODULES IN STRING 12 #10 AWG PV-WIRE 12 CS6R-395MS-HL 395 W 371.9 W 395 WIRE SIZE CALCULATIONS PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW E 1.1 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW JB B O X WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.13(B) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CEC 110.27(C) In v e r t e r / P V L o a d WARNING THE DISCONNECTION OF THE GROUNDING CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT CEC 690.31(E) CEC 690.54 AC D i s c o n n e c t CEC 690.54 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.13(B) PM M E T E R Ma i n / S u b P a n e l CEC 690.54 CEC 690.13 (E), CEC 705.12(B)(C-D) & CEC 690.59 CEC 690.15 (B) & CEC 690.33(D)(2) CEC 690.13(B) SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUIT! CEC 710.15(C) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CEC 110.27(C) WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.13(B) CEC 705.12 (B)(3)(2) LABELING REQUIREMENTS FOR ARTICLE 690 CEC 690.13(B) Each PV system disconnecting means shall plainly indicate whether in the open (off) or closed (on) position and be permanently marked “PV SYSTEM DISCONNECT” or equivalent. Additional markings shall be permitted based upon the specific system configuration. CEC 690.13(E) Type of Disconnect. The PV system disconnecting means shall simultaneously disconnect the PV system conductors that are not solidly grounded from all conductors of other wiring systems. The PV system disconnecting means or its remote operating device or the enclosure providing access to the disconnecting means shall be capable of being locked in accordance with 110.25. CEC 690.15(B) An isolating device shall not be required to have an interrupting rating. Where an isolating device is not rated for interrupting the circuit current, it shall be marked "Do Not Disconnect Under Load" or "Not for Current Interrupting." An isolating device shall not be required to simultaneously disconnect all current-carrying conductors of a circuit. CEC 690.31(B)(1) PV system dc circuit conductors shall be identified at all termination, connection, and splice points by color coding, marking tape, tagging, or other approved means. CEC 690.31(D)(2) Unless located and arranged so the purpose is evident, the following wiring methods and enclosures that contain PV system dc circuit conductors shall be marked with the wording PHOTOVOLTAIC POWER SOURCE or SOLAR PV DC CIRCUIT by means of permanently affixed labels or other approved permanent marking. CEC 690.31(D)(2) PV system dc circuit labels shall appear on every section of the wiring system that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing between labels or markings, or between a label and a marking, shall not be more than 3 m (10 ft). Labels required in this section shall be suitable for the environment where they are installed. CEC 690.31(E) Solidly-grounded bipolar PV systems shall be clearly marked with a permanent, legible warning notice indicating that the disconnection of the grounded conductor(s) may result in overvoltage on the equipment. CEC 690.33(D)(2) Interruption of Circuit. Connectors shall be a type that requires the use of a tool to open and marked “Do Not Disconnect Under Load” or “Not for Current Interrupting”. CEC 690.6 Alternating-current (AC) modules and systems: The PV source circuit, conductors, and inverters shall be considered as internal components of an ac module or ac module system. CEC 690.53 A permanent readily visible label indicating the highest maximum dc voltage in a PV system, calculated in accordance with 690.7, shall be provided by the installer. CEC 690.54 All interactive system(s) points of interconnection with other sources shall be marked at an accessible location at the disconnecting means as a power source and with the rated ac output current and the nominal operating ac voltage. CEC 690.55 The PV system output circuit conductors shall be marked to indicate polarity where connected to energy storage systems. CEC 690.56(A) Plaques or directories shall be installed in accordance with 705.10. CEC 690.56(C)(2) A rapid shutdown switch shall have a label located on or no more than 1 meter (3 ft) from the switch. CEC 690.59 PV systems connected to other sources shall be installed in accordance with Parts I and II of Article 705 and Article 712. SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH ON THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY CFC 1205.4.1(1) & CEC 690.56(C) CEC 690.56(C)(2) CEC 690.31(D)(2) CEC 690.31(D)(2)CO N D U I T RATED AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT WARNING RATED AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT RATED AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT MAIN PHOTOVOLTAIC SYSTEM DISCONNECT WARNING CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING DO NOT DISCONNECT UNDER LOAD RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM WARNING: PHOTOVOLTAIC POWER SOURCE WARNING PHOTOVOLTAIC POWER SOURCE DO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOW FOR SOLAR PHOTOVOLTAIC SYSTEMS THAT SHUT DOWN THE ARRAY AND THE CONDUCTORS LEAVING THE ARRAY, A LABEL SHALL BE PROVIDED. THE FIRST TWO LINES OF THE LABEL SHALL BE UPPERCASE CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 INCH (10 MM) IN BLACK ON A YELLOW BACKGROUND. THE REMAINING CHARACTERS SHALL BE UPPERCASE WITH A MINIMUM HEIGHT OF 3/16 INCH (5 MM) IN BLACK ON A WHITE BACKGROUND. [CFC 1205.4.1(1)] 240 Vac 240 Vac 240 Vac CEC 690.13(B) AC DISCONNECT PHOTOVOLTAIC 25.0 A 25.0 A 25.0 A CEC 705.10 CAUTION MULTIPLE SOURCES OF POWER CEC 705.10 CAUTION MULTIPLE SOURCES OF POWER CEC 690.53 MAXIMUM SYSTEM VOLTAGE RATED SHORT CIRCUIT CURRENT N/AMAX RATED AC OPERATING VOLTAGE N/ARATED AC OPERATING VOLTAGE MAX RATED AC OPERATING CURRENT RATED AC OPERATING CURRENT N/A N/A N/A N/A CAUTION N 0° S 180° E 90° W 270° POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: CEC 705.10 & CEC 690.56(B) Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipment or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacement, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background & white lettering. CODE REQUIRED SIGNAGE PV 2.0 S S P R U C E S T SOLAR INVERTER PV SYSTEM DISCONNECT FOR UTILITY OPERATION SERVICE POINT & UTILITY METERING SOLAR ARRAY ON THE ROOF SOLAREDGE ENERGY BANK BATTERY 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW PHOTOVOLTAIC SYSTEM 1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-US (240V) Solar Edge S440 Power Optimizers12 4.74 KW DC 12 Canadian Solar 395W Modules (CS6R-395MS-HL)MODULE MAP [FOR INSTALLER USE ONLY]PV 2.1 Solar Array 2 9 Canadian 395W Modules 9 S440 Optimizers Tilt: 9 Deg Azimuth: 180 Deg Solar Array 1 3 Canadian 395W Modules 3 S440 Optimizers Tilt: 9 Deg Azimuth: 180 Deg 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW INVERTERPHOTOVOLTAIC SYSTEM 1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-US (240V) Solar Edge S440 Power Optimizers12 4.74 KW DC 12 Canadian Solar 395W Modules (CS6R-395MS-HL) INVERTER MAP [FOR INSTALLER USE ONLY]PV 3.0 Solar Array 2 9 Canadian 395W Modules 9 S440 Optimizers Tilt: 9 Deg Azimuth: 180 Deg Solar Array 1 3 Canadian 395W Modules 3 S440 Optimizers Tilt: 9 Deg Azimuth: 180 Deg 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW MODULE DATA SHEET PV 3.1 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW INVERTER DATA SHEET PV 4.0 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW OPTIMIZER DATA SHEET PV 4.1 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW RACKING DATA SHEET PV 5.0 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW ATTACHMENT DATA SHEET PV 5.1 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW GROUNDING SPECS PV 6.0 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED May 2, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.74KW PV SYSTEM AC SIZE 4.42KW BATTERY DATA SHEET PV 6.1 222 S Spruce St 9/12/2024 -.. , -·· CLEAN ENERGY SOLUTIONS To whom it may concern, Clean Energy Solutions Inc 417 W. Allen Ave Suite #105 an Dimas CA, 91773 (800) 994-1134This letter authorizes Victor Barcelo to pull permits and business licenses on behalf of Clean Energy Solutions Inc (CSLB 998787). If you have any question, please call us at (800) 994-1134. Sincerely, David Gomez CEO 222 S Spruce St 9/12/2024 222 S Spruce St 9/12/2024 222 S Spruce St 9/12/2024 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.Will the PV system weigh maximum 4 pounds per square feet or less? 5.Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.Will the PV system be installed without using any ballast system or counter-weight system? 8.Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M -19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Bernard Albosta 998787 Bernard Albosta mluna@cleanenrgysolar.org 222 S Spruce ST, SANTA ANA, CA 92701 8/05/2024800-994-1134 222 S Spruce St 9/12/2024 222 S SPRUCE ST., SANTA ANA, CA 92703 TORRES, ROSENDO CLEAN ENERGY SOLUTIONS, INC 1055 WEST 7TH STR., 33RD FLR, LOS ANGELES, CA 90017 800-994-1134 Design Criteria 1- Code: CALIFORNIA BLDG CODE 2022 / ASCE 7-16 2 - Wind: 95 MPH, Exposure: C 3 - Wood Species: DF-L No. 1 (SG = 0.5 ) Notice: Use restrictions of these calculations. The attached Calculations are valid only when bearing original signature hereon. Contractor/Client to verify existing dimensions/conditions prior to construction & solar racking is installed per manufacturer span requirements. The use of these calculations is solely intended for the above mentioned project. 1-844-PV ELITE | info@yoursolarplans.com 3000 E. Birch Street Suite 201 | Brea CA 92821 5/3/2024 Structural Calculations for SOLAR POWER SYSTEM CONNECTION CHECK AT: Job: 222 S Spruce St 9/12/2024 This is a beta release of the new ATC Hazards by Location website. Please contact us with feedback. The ATC Hazards by Location website will not be updated to support ASCE 7-22. Find out why. Hazards by Location Search Information Address:222 S Spruce St, Santa Ana, CA 92703, USA Coordinates:33.7439497, -117.8896324 Elevation:91 ft Timestamp:2024-05-03T17:56:34.893Z Hazard Type:Wind ASCE 7-16 MRI 10-Year 66 mph MRI 25-Year 71 mph MRI 50-Year 77 mph MRI 100-Year 81 mph Risk Category I 89 mph Risk Category II 95 mph Risk Category III 102 mph Risk Category IV 106 mph ASCE 7-10 MRI 10-Year 72 mph MRI 25-Year 79 mph MRI 50-Year 85 mph MRI 100-Year 91 mph Risk Category I 100 mph Risk Category II 110 mph Risk Category III-IV 115 mph ASCE 7-05 ASCE 7-05 Wind Speed 85 mph The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Please note that the ATC Hazards by Location website will not be updated to support ASCE 7-22. Find out why. Disclaimer Hazard loads are interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer. Per ASCE 7, islands and coastal areas outside the last contour should use the last wind speed contour of the coastal area – in some cases, this website will extrapolate past the last wind speed contour and therefore, provide a wind speed that is slightly higher. NOTE: For queries near wind-borne debris region boundaries, the resulting determination is sensitive to rounding which may affect whether or not it is considered to be within a wind-borne debris region. Mountainous terrain, gorges, ocean promontories, and special wind regions shall be examined for unusual wind conditions. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. 91 ft Map data ©2024 Google, INEGI Report a map error 5/3/24, 10:57 AM ATC Hazards by Location https://hazards.atcouncil.org/#/wind?lat=33.7439497&lng=-117.8896324&address=222 S Spruce St%2C Santa Ana%2C CA 92703%2C USA 1/1 222 S Spruce St 9/12/2024 ASCE 29.4.4 Rooftop Solar Panels Parallel to the Roof Surface on Buildings of All Heights and Roof Slopes. Roof Slope =9 ° Roof Shape Gable Tributary Width s =4.00 ft Tributary Length l =2.83 ft Effective Area Ae =11.30 f 2 Height of Structure h =15 ft Wind Speed V =95 mph Exposure Categor C Building Width B =25 ft Building Length L =80 ft Zone Width a =3 ft Elevation Height zg =91 ft Wind Directionality Kd =0.85 Topography Factor Kt =1.00 Ground Elevation Factor Ke =1.00 Velocity Pressure Exposure Coefficient Kz =0.85 Velocity Pressure qz = 0.00256KzKztKdKeV2 =16.62 psf Solar Array Pressure Equalization a =0.79 Array Edge Factor E =1.50 Zone GCp p = qz(GCp)(E)(a) 3 - - 3r 3.57 -70.75 3e 2.99 -59.17 2 - - 2r 2.99 -59.17 2e - - 2n 2.99 -59.17 1 - - 1' - - 222 S Spruce St 9/12/2024 LAG SCREW ANALYSIS Loads Wind Pressures qz =-59.17 psf Solar Panel Load QD =3 psf Panel Length l =5.650 ft Panel Width b 3.7167 ft Attachment Spacing s =4 ft Portrait Tributary Area At =11.30 ft2 Wind Load PW = qz * At =-669 lbs Dead Load PD = QD * At =33.9 lbs Uplift Pa = 0.6 PD + 0.6 Pw =-381 lbs Landscape Tributary Area At = b * s =7.4333 ft2 Wind Load PW = qz * At =-440 lbs Dead Load PD = QD * At =22.3 lbs Uplift Pa = 0.6 PD + 0.6 Pw =-251 lbs Lag Screw Specific Gravity of Lumber SG =0.50 (Douglas Fir-Larch) Diameter of Lag Screw D =5/16 in Withdraw Design /in 1800*SG3/2*D3/4 =266 lbs/in Depth of Embedment lp =2.50 in Total Nominal Withdrawal Value W = W * l p =665 lbs Load Duration Factor CD =1.6 Withdrawal Design Value W' = W * C D =1064 lbs Demand Capacity Ratio DCR = Pa / W'=0.36 < 1 OK 222 S Spruce St 9/12/2024 ASCE 30.3.2 Design Wind Pressure Beam/ Top Chord Check Roof Slope =9 ° Roof Shape Gable Tributary Width s =1.33 ft Tributary Length L =12.75 ft Effective Area A = L ( MAX [ s , L/3] )=54 f 2 Height of Structure h =15 ft Wind Speed V =95 mph Exposure Categor C Building Width B =25 ft Building Length L =80 ft Zone Width a =3 ft Elevation Height zg =91 ft Wind Directionality Kd =0.85 Topography Factor Kt =1.00 Ground Elevation Factor Ke =1.00 Velocity Pressure Exposure Coefficient Kz =0.85 Velocity Pressure qz = 0.00256KzKztKdKeV2 =16.62 psf Internal Pressure Coefficient (GCpi)=-0.18 Zone GCp p = qz [(GCp) - (Gcpi)] 3 - - 3r 2.72 -48.12 3e 2.63 -46.72 2 - - 2r 2.63 -46.72 2e - - 2n 2.63 -46.72 1 - - 1' - - 222 S Spruce St 9/12/2024 Beam/ Top Chord Check Lumber: Moment Demand # of Attachment per Rafter NA =Span :Orientation Lenght (ft) : Dead Load Roof Material:QD =psf Live Load QLr =psf Wind Load p = psf Snow Load QS =psf Rafter Spacing s = in Wind Load, Portrait Portrait UL = Wind Load, Landscape Landscape UW = Linear Dead Load wd =plf Live Load wLr = plf Start ft Start ft End ft End ft Snow Load ws = plf Start ft Start ft End ft End ft Ma, Moment D lb-ft D+Lr lb-ft D+S lb-ft 0.6D+0.6W lb-ft D+0.45W+0.75Lr lb-ft D+0.45W+0.75S lb-ft Moment Capacity Framing Member Size Lumber Grade : DF-L No. 1 CM = 1 Ct = 1 Cr= CF = fb =psi Cfu =Ci = Breadth b = in Depth d = in Section Modulus Sx = bd2 / 6 =in3 Bending Stress Capacity Fb = CM * Ct * Cr * CF * fb =psi Table 4.3.1 NDS 2015 Deflection Limit E = ksi I =in4 Transient Deflection in Transient Deflection Allowed > [OKAY] Total Deflection in Total Deflection Allowed > [OKAY] -46.72 DF-L No. 1 4 j lj (ft)pd,j (lbs) pw,j (lbs) ps,j (lbs) Portrait 1 2.2 33.9 -528 0.0 6.4 33.9 -528 -528 0.0 4 12.1 33.9 -528 0.0 0.0 11.25 0.00 0.00 0.00 1.50 Portrait 3 7.9 33.9 10.00 1 2 3 4 Eave 2 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0 0.0Portrait0 0.0 0.0 0 0.0 13.3 26.7 0.0 0.0 0.0 0.0 0 0.0Portrait0 0.022.3 -347 0 0 0.0 0 1.5 0 0 0.0 Portrait 1.5 0.0Portrait0 0.0 0.0 AT (ft2) 11.3 7.4333 pd (lbs) 33.9 -528 pw (lbs) ps (lbs) 0 0.00 2x6 1.15 1.3 12.75 0.00 12.75 1000 1.50 5.50 374 684 374 1413 855 855 DCR 0.9 1346 psi D 593 psi 0.44 7.56 1495 CD Fb' = CD * Fb ASD Load Ma / Sx 1.15 1719 psi D+S 593 psi 0.34 OKAY OKAY 1.25 1869 psi D+Lr 1086 psi 0.58 OKAY 1.6 2392 psi 0.829 163 120 1700 20.80 0.6D+0.6W 2243 psi 0.94 OKAY 1.0 1 20 0.00 16 HINGL 0.678 199 180 1.6 2392 psi D+0.45W+0.75S 1356 psi 0.57 OKAY 1.6 2392 psi D+0.45W+0.75L 1356 psi 0.57 OKAY 𝑴𝒙 𝑹𝒊𝒙 𝑳𝒊 𝑷𝒋𝒙 𝒍𝒋 𝒘𝒅𝒙𝟐 𝟐 ‐500.0 0.0 500.0 1000.0 1500.0 0.000 2.000 4.000 6.000 8.000 10.000 12.000 14.000 222 S Spruce St 9/12/2024 EISMIC WEIGHT COMPARISON / ANALYSIS - (PER CEBC 2022 Part 10 Chapter 5 Section 502.5) PV System Weight Module Model CS Panel Weight W panel = 49.4 lbs Number of Panels NPV = 12 Total PV System Weight W PV = W panel * NPV =592.8 lbs Existing Roof Weight Roof Weight QD =10.0 psf Building Length Lbuild =80 ft Building Width W build =25 ft Roof Area Abuild =2000 ft2 Building Perimeter Pbuild =210 ft Wall Height ht =8 ft Wall weight Qwall =15 psf Interior wall weight Qint =10 psf Roof Load W floor = Abuild * QD =20000 lbs Wall Load wall = ht /2 * Qwall * Pbuild + Abuild * Qint /=22600 lbs Total Story Weight W build = W floor + W wall =42600 lbs Percentage Weight Increas WPV / Wbuild = 1.39% < 10% OKAY 222 S Spruce St 9/12/2024 PV SYSTEM AS INDICATED September 17, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.80KW PV SYSTEM AC SIZE 4.44KW 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. OWNER SCOPE PROJECT ADDRESS PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX PHOTOVOLTAIC NOTES SATELLITE VIEW BUILDING INFORMATION: ELECTRICAL INFORMATION MAIN SERVICE PANEL BUSBAR RATING MAIN SERVICE BREAKER RATING 1ɸ, 3W, 120/240V RACKING INFORMATION Main Service Panel Solar Module Micro Inverter / Optimizer EMT / FMT / PVC / RMC type conduit/ Romex NM Cable/ FNMT (Fluid non-metalic tube) 36'' SetbackInverter Utility Meter Production Meter PV Load Center IQ Combiner Box Junction Box Sunpower PV Supervisor 18'' Setback EV Outlet CONSTRUCTION TYPE: V-B ROOF TYPE AHJ APN LOT AREA LIVING AREA MSP UM PM INV PV PVS6 IQ J/B EV ROSENDO TORRES 12 1 SOLAR EDGE SE5700H-USMNUBL15 (240V) 222 S SPRUCE ST, SANTA ANA, CA 92703 SSP Service Sub Panel COMPOSITION SHINGLE 1,785 SQFT 00732115 CITY OF SANTA ANA ROOF MOUNT INSTALLATION OF DC PHOTOVOLTAIC SYSTEM 4.80 KW DC 4.80 KW 4.44 KW AC NEW UPGRADED ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA HISTORICAL CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA REFERENCED STANDARDS CODE 2022 CALIFORNIA ADMINISTRATIVE STANDARDS CODE 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8 .INVERTER IS EQUIPPED W/ INTEGRATED GFCI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 12. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER CEC 250.122 13. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 14. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS 6,741 SQFT Battery BackupBB Auto TransformerAT Solar Edge Meter EnclosureSEM Distribution PanelDP Rapid Shutdown Controller RSC Rapid Shutdown BoxRSB Itron Meter IM UNIT INDEX CODE REFERENCES IRONRIDGE RACKING RAFTERS 2"X6" @ 16" O.C OCCUPANCY: R ONE STORY BUILDING 200A 200A LONGI SOLAR 400W LR5-54HABB-400M (don't delete this note) AC DisconnectACD Visible Lockable Labeled DisconnectVLLD 1 0 0 TITLE SHEET SINGLE LINE DIAGRAM CODE REQUIRED SIGNAGE E 1.1 PV 2.0 ATTACHMENT LAYOUTS 1.0 PV 2.1 PV 3.0 INVERTER DATA SHEET MODULE DATA SHEET RACKING SPECIFICATIONS ATTACHMENT SPECIFICATIONS ROOF PLAN MODULE MAP WIRE SIZE CALCULATIONS INVERTER MAP GROUNDING SPECIFICATIONS OPTIMIZER DATA SHEET PV 0.0 E 1.0 SITE PLANPV 1.0 PV 3.1 PV 4.0 PV 4.1 PV 5.0 PV 5.1 PV 6.0 PV 6.1 BATTERY DATA SHEET TITLE SHEET SOLAREDGE BAT-10K1PS0B-01 ENERGY BANK 10KWH **The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. *** Bldg#: 101120938 Elec#: 20184054 REV TO: Bldg#: 101120572 Elec#: 20183818 Approvals: Elec: M Smith 222 S Spruce St 10/1/2024 PV SYSTEM AS INDICATED September 17, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.80KW PV SYSTEM AC SIZE 4.44KW ROOF AREA CALCULATIONS FIRE SPRINKLERS - NO TOTAL ROOF AREA (SQ.FT.) - 3085 SOLAR AREA (SQ.FT.) - 252 % OF COVERED AREA - 8.2% PHOTOVOLTAIC SYSTEM 1 Solar Edge 5.7 Kw Inverter SE5700H-USMNUBL15 (240V) Solar Edge S440 Power Optimizers12 FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT4.80 KW DC 12 Longi Solar 400W Modules (LR5-54HABB-400M) ROOF PLAN 36'' Setback 18'' Setback PV 0.0 N 0° S 180° E 90° W 270° SCALE 1" = 10' MSP ACD INV SolarEdge Energy Bank Battery Gate Gate J/B S S P R U C E S T Solar Array 2 9 Longi 400W Modules 9 S440 Optimizers Tilt: 9 Deg Azimuth: 180 Deg Solar Array 1 3 Longi 400W Modules 3 S440 Optimizers Tilt: 9 Deg Azimuth: 180 Deg 222 S Spruce St 10/1/2024 PV SYSTEM AS INDICATED September 17, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.80KW PV SYSTEM AC SIZE 4.44KW SITE PLAN PV 1.0 N 0° S 180° E 90° W 270° SCALE 1" = 15' MSP Driveway Pu b l i c S i d e w a l k S S P R U C E S T S S P R U C E S T Gate Gate 110' 65' 16' 43' 36' 7' PROPERTY LINE (E) MAIN HOUSE ACD INV SolarEdge Energy Bank Battery 222 S Spruce St 10/1/2024 PV SYSTEM AS INDICATED September 17, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.80KW PV SYSTEM AC SIZE 4.44KW STRUCTURAL STAMPROOF PITCH ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE FRAMING SIZE PENETRATION PATTERN 9° RACKING TYPE MAX PENETRATION SPACING ROOFING LAYERS WIND SPEED 95 MPH SNOW LOAD 0 PSF EXPOSURE C LAG BOLTS MOUNTS AND MOUNTING HARDWARE WILL BE SEALED WITH CHEM LINK SEALANT OR EQUIVALENT. MODULE WEIGHT (LBS) # OF MODULES TOTAL MODULE WEIGHT (LBS) RACK WEIGHT (LBS) TOTAL SYSTEM WEIGHT (LBS) # OF STANDOFFS LOADING PER STANDOFF (LBS) TOTAL MODULE AREA (SQ.FT.) LOADING (PSF) WEIGHT LOAD CALCULATION INDEX ROOF SHEATHED WITH 1/2" PLYWOOD AND UPPER SURFACE IS FACED WITH FELT PAPER TOTAL ROOF AREA (Sq. FT) % OF COVERED AREA PV MODULE MODEL # OPTIMIZERS WEIGHT (LBS) 12 Roof 1 Layer Comp Shingle Ironridge XR10 Rafter Stacked 48"2"X6" @ 16" O.C 3 1 2 4 ITEM NO. 1 DESCRIPTION 2 3 4 BOLT LAG 5/16 X 4.75" ASSY, FLASHING ASSY, CAPFOOT WASHER, EPDM BACKED Qty in Kit 4 4 4 4 5/16" X 4.75" Flash Foot 2 MIN 2.5" EMBEDMENT RACKING RAIL ATTACHMENT ROOF FRAMING 30 252 3085 595 119 18 732 24.4 2.91 8.2 2''X6'' Blocking 2''X4'' Support 2''X4'' Purlin 2''X6'' Collar Tie SOLAR MODULE ROOF ASCE 7-16 Max 3.5'' 49.6 LR5-54HABB-400M ATTACHMENT LAYOUT S 1.0 48"16" 222 S Spruce St 10/1/2024 PV SYSTEM AS INDICATED September 17, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.80KW PV SYSTEM AC SIZE 4.44KW ITEM DESCRIPTION QTY# PV MODULE MAIN SERVICE PANEL MAIN SERVICE PANEL & UTILITY METER BUSBAR RATING BREAKER RATING 1 ITEM DESCRIPTION QTY# PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3 1 1 1 4 3 1 4 6 MAIN SERVICE PANEL 120/240V 1P,3W 2 EXISTING GROUNDING SYSTEM UTILITY 2 3 380 V 99.0 % NEMA 4 13.5 A 24.0 A 11,520 W 5,760 W INVERTER PEAK PWR TRACKING VOLTAGE MAXIMUM INPUT CURRENT MAXIMUM OUTPUT CURRENT MAXIMUM INPUT POWER MAXIMUM CONTINUOUS OUTPUT POWER 4 5700W 1 SOLAREDGE SE5700H-USMNUBL15 (240V) ENCLOSURE: INVERTER EFFICIENCY SOLAREDGE POWER OPTIMIZER RATED DC INPUT POWER MAXIMUM INPUT VOLTAGE MPPT RANGE MAXIMUM SHORT CIRCUIT CURRENT (Isc) MAXIMUM OUTPUT CURRENT OPTIMIZER WEIGHT MAXIMUM POWER PER STRING 5 S440 440W 60 Vdc 8 to 60 Vdc 14.5 Adc 15 Adc 1.5 Lbs 12POWER OPTIMIZER 30AAC DISCONNECT NON FUSED AC DISCONNECT LOCKABLE, BLADE TYPE, NEMA 3R, 120/240V 16 NEW UPGRADED NEW 2 1 33 200A 200A 200A FOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3 INSTALL 2P 30A CB(PV) AT OPPOSITE END OF BUS FROM MAIN FEEDER CB 12 LONGI SOLAR 400W LR5-54HABB-400M Voc = 37.05V Vmp = 30.94V Isc = 13.72A Imp = 12.93A (N)200A String: (12) Modules, (12) Optimizers SINGLE LINE DIAGRAM 7 (2)#10 AWG (10-12 AWG), 600V insulated (1)#24 AWG (16-24 AWG), 600V insulated or CAT6 1" EMT TYPE Conduit BATTERY BACKUP BATTERY BACKUP SYSTEMS SOLAR EDGE ENERGY BANK 10kWh, BAT-10K1P 17 E 1.0 222 S Spruce St 10/1/2024 FROM PV MODULES TO JBOX FROM JBOX TO INVERTER (2)1 (1) #6 AWG BARE CU EGC, 2 #8 AWG CU EGC, (3) 3 (1) #8 AWG CU EGC, MAXIMUM INVERTER OUTPUT CURRENT (A) TEMPERATURE FACTOR TEMPERATURE ADJUSTMENT (A) OUTPUT CALCULATIONS PV SYSTEM MAX DC OUTPUT PV SYSTEM MAX AC OUTPUT MAXIMUM POWER (W) PEAK PWR TRACKING VOLTAGE (V) CONSIDER CONTINUOUS COEFFICIENT SHORT CIRCUIT CURRENT (A) ADJUSTED CONDUCTOR AMPACITY (A) 1.25 1.25 1.25 0.91 (2) (1) Pmax (PTC Rating) 380 99 %1 #10 AWG THWN-2 24.0 * 1.25 / 0.91 24.0 33.0 SOLAR EDGE SE5700H-USMNUBL15 (240V) 24.0 * 1.25 30.0 1 1/2'' (TEMP - 39 + 22 = 61C)0.58 RACEWAY HEIGHT FROM ROOF ADJST. FACTOR (1 thru 3 WIRES)1.0 FREE IN THE AIR, 3/4'' EMT TYPE CONDUIT BETWEEN ARRAYS 3/4'' EMT TYPE CONDUIT 1'' EMT TYPE CONDUIT MAIN SERVICE PANEL RATING BUSBAR RATING MAIN BREAKER PV BACKFEED BREAKER SIZE 120% RULE: MAX ALLOWED FEED 30A */*1.25 *1.2512400 380 19.7 / /19.7 0.58 1.0 34.0 #10 AWG THWN-2 WIRE CHART WIRE CHART *12 400 4.80 KW * *12 373.7 0.99 4.44 KW CONSIDER CONTINUOUS COEFFICIENT CONSIDER CONTINUOUS COEFFICIENT 200A 200A 240A 200A ''MB'' + 30A "SOLAR" = 230A ≤ 240A MAX FROM INVERTER TO MAIN SERVICE PANEL CONSIDER CONTINUOUS (A) MAX NUMBER OF MODULES IN STRING 12 #10 AWG PV-WIRE 12 400 LR5-54HABB-400M 400 W 373.7 W WIRE SIZE CALCULATIONS PV SYSTEM AS INDICATED September 17, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.80KW PV SYSTEM AC SIZE 4.44KW E 1.1 222 S Spruce St 10/1/2024 PV SYSTEM AS INDICATED September 17, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.80KW PV SYSTEM AC SIZE 4.44KW JB B O X WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.13(B) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CEC 110.27(C) In v e r t e r / P V L o a d WARNING THE DISCONNECTION OF THE GROUNDING CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT CEC 690.31(E) CEC 690.54 AC D i s c o n n e c t CEC 690.54 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.13(B) PM M E T E R Ma i n / S u b P a n e l CEC 690.54 CEC 690.13 (E), CEC 705.12(B)(C-D) & CEC 690.59 CEC 690.15 (B) & CEC 690.33(D)(2) CEC 690.13(B) SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUIT! CEC 710.15(C) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CEC 110.27(C) WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.13(B) CEC 705.12 (B)(3)(2) LABELING REQUIREMENTS FOR ARTICLE 690 CEC 690.13(B) Each PV system disconnecting means shall plainly indicate whether in the open (off) or closed (on) position and be permanently marked “PV SYSTEM DISCONNECT” or equivalent. Additional markings shall be permitted based upon the specific system configuration. CEC 690.13(E) Type of Disconnect. The PV system disconnecting means shall simultaneously disconnect the PV system conductors that are not solidly grounded from all conductors of other wiring systems. The PV system disconnecting means or its remote operating device or the enclosure providing access to the disconnecting means shall be capable of being locked in accordance with 110.25. CEC 690.15(B) An isolating device shall not be required to have an interrupting rating. Where an isolating device is not rated for interrupting the circuit current, it shall be marked "Do Not Disconnect Under Load" or "Not for Current Interrupting." An isolating device shall not be required to simultaneously disconnect all current-carrying conductors of a circuit. CEC 690.31(B)(1) PV system dc circuit conductors shall be identified at all termination, connection, and splice points by color coding, marking tape, tagging, or other approved means. CEC 690.31(D)(2) Unless located and arranged so the purpose is evident, the following wiring methods and enclosures that contain PV system dc circuit conductors shall be marked with the wording PHOTOVOLTAIC POWER SOURCE or SOLAR PV DC CIRCUIT by means of permanently affixed labels or other approved permanent marking. CEC 690.31(D)(2) PV system dc circuit labels shall appear on every section of the wiring system that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing between labels or markings, or between a label and a marking, shall not be more than 3 m (10 ft). Labels required in this section shall be suitable for the environment where they are installed. CEC 690.31(E) Solidly-grounded bipolar PV systems shall be clearly marked with a permanent, legible warning notice indicating that the disconnection of the grounded conductor(s) may result in overvoltage on the equipment. CEC 690.33(D)(2) Interruption of Circuit. Connectors shall be a type that requires the use of a tool to open and marked “Do Not Disconnect Under Load” or “Not for Current Interrupting”. CEC 690.6 Alternating-current (AC) modules and systems: The PV source circuit, conductors, and inverters shall be considered as internal components of an ac module or ac module system. CEC 690.53 A permanent readily visible label indicating the highest maximum dc voltage in a PV system, calculated in accordance with 690.7, shall be provided by the installer. CEC 690.54 All interactive system(s) points of interconnection with other sources shall be marked at an accessible location at the disconnecting means as a power source and with the rated ac output current and the nominal operating ac voltage. CEC 690.55 The PV system output circuit conductors shall be marked to indicate polarity where connected to energy storage systems. CEC 690.56(A) Plaques or directories shall be installed in accordance with 705.10. CEC 690.56(C)(2) A rapid shutdown switch shall have a label located on or no more than 1 meter (3 ft) from the switch. CEC 690.59 PV systems connected to other sources shall be installed in accordance with Parts I and II of Article 705 and Article 712. SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH ON THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY CFC 1205.4.1(1) & CEC 690.56(C) CEC 690.56(C)(2) CEC 690.31(D)(2) CEC 690.31(D)(2)CO N D U I T RATED AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT WARNING RATED AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT RATED AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT MAIN PHOTOVOLTAIC SYSTEM DISCONNECT WARNING CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING DO NOT DISCONNECT UNDER LOAD RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM WARNING: PHOTOVOLTAIC POWER SOURCE WARNING PHOTOVOLTAIC POWER SOURCE DO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOW FOR SOLAR PHOTOVOLTAIC SYSTEMS THAT SHUT DOWN THE ARRAY AND THE CONDUCTORS LEAVING THE ARRAY, A LABEL SHALL BE PROVIDED. THE FIRST TWO LINES OF THE LABEL SHALL BE UPPERCASE CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 INCH (10 MM) IN BLACK ON A YELLOW BACKGROUND. THE REMAINING CHARACTERS SHALL BE UPPERCASE WITH A MINIMUM HEIGHT OF 3/16 INCH (5 MM) IN BLACK ON A WHITE BACKGROUND. [CFC 1205.4.1(1)] 240 Vac 240 Vac 240 Vac CEC 690.13(B) AC DISCONNECT PHOTOVOLTAIC 24.0 A 24.0 A 24.0 A CEC 705.10 CAUTION MULTIPLE SOURCES OF POWER CEC 705.10 CAUTION MULTIPLE SOURCES OF POWER CEC 690.53 MAXIMUM SYSTEM VOLTAGE RATED SHORT CIRCUIT CURRENT N/AMAX RATED AC OPERATING VOLTAGE N/ARATED AC OPERATING VOLTAGE MAX RATED AC OPERATING CURRENT RATED AC OPERATING CURRENT N/A N/A N/A N/A CAUTION N 0° S 180° E 90° W 270° POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: CEC 705.10 & CEC 690.56(B) Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipment or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacement, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background & white lettering. CODE REQUIRED SIGNAGE PV 2.0 S S P R U C E S T SOLAR INVERTER PV SYSTEM DISCONNECT FOR UTILITY OPERATION SERVICE POINT & UTILITY METERING SOLAR ARRAY ON THE ROOF SOLAREDGE ENERGY BANK BATTERY 222 S Spruce St 10/1/2024 PV SYSTEM AS INDICATED September 17, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.80KW PV SYSTEM AC SIZE 4.44KW PHOTOVOLTAIC SYSTEM 1 Solar Edge 5.7 Kw Inverter SE5700H-USMNUBL15 (240V) Solar Edge S440 Power Optimizers12 4.80 KW DC 12 Longi Solar 400W Modules (LR5-54HABB-400M) MODULE MAP [FOR INSTALLER USE ONLY]PV 2.1 Solar Array 2 9 Longi 400W Modules 9 S440 Optimizers Tilt: 9 Deg Azimuth: 180 Deg Solar Array 1 3 Longi 400W Modules 3 S440 Optimizers Tilt: 9 Deg Azimuth: 180 Deg 222 S Spruce St 10/1/2024 PV SYSTEM AS INDICATED September 17, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.80KW PV SYSTEM AC SIZE 4.44KW INVERTERPHOTOVOLTAIC SYSTEM 1 Solar Edge 5.7 Kw Inverter SE5700H-USMNUBL15 (240V) Solar Edge S440 Power Optimizers12 4.80 KW DC 12 Longi Solar 400W Modules (LR5-54HABB-400M) INVERTER MAP [FOR INSTALLER USE ONLY]PV 3.0 Solar Array 2 9 Longi 400W Modules 9 S440 Optimizers Tilt: 9 Deg Azimuth: 180 Deg Solar Array 1 3 Longi 400W Modules 3 S440 Optimizers Tilt: 9 Deg Azimuth: 180 Deg 222 S Spruce St 10/1/2024 PV SYSTEM AS INDICATED September 17, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.80KW PV SYSTEM AC SIZE 4.44KW MODULE DATA SHEET PV 3.1 222 S Spruce St 10/1/2024 PV SYSTEM AS INDICATED September 17, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.80KW PV SYSTEM AC SIZE 4.44KW INVERTER DATA SHEET PV 4.0 222 S Spruce St 10/1/2024 PV SYSTEM AS INDICATED September 17, 2024 ROSENDO TORRES 222 S SPRUCE ST, SANTA ANA, CA 92703 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.80KW PV SYSTEM AC SIZE 4.44KW OPTIMIZER DATA SHEET PV 4.1 222 S Spruce St 10/1/2024