HomeMy WebLinkAbout1927 & 1929 S Hickory St - PlanSS SS SS SS SS SS SS SS WL WL WL WL WL WL WL G G G G G G G G G G G G G G G SS SS SS SS SS SS SS SS WL WL WL WL WL WL WL G G G G G G G G G G G G G G G G G G G WL WL WL SS SS WL WLWL SS SSSS G GG EL ELEL S. HICKORY ST.S. HICKORY ST. 47.00'47.00'PROPERTY LINEPROPERTY LINE 10 8 . 0 0 ' 10 8 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 10 8 . 0 0 ' 10 8 . 0 0 ' 10 8 . 0 0 ' 10 8 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 10 8 . 0 0 ' 10 8 . 0 0 ' 1929 S HICKORY ST., SANTA ANA, CA (E) SINGLE-FAMILY DWELLING (E ) C O N C R E T E D R I V E W A Y 10 8 ' - 0 " 47' - 0" 5' - 0" WM (E) WATER METER (E) SEWER LATERAL (E) GRASS (E) GRASS G (E) UNDERGROUND GAS METER (E ) F R O N T S E T B A C K 80 ' - 6 " (E) ELECTRIC PANEL (E) SHED TO BE REMOVED 46.00'46.00' 47.00'47.00' PROPERTY LINEPROPERTY LINE 46.00'46.00' (E) MULCH SIDEWALK 7' - 6 " 4' - 0" 15' - 0" 31 ' - 6 " UNPERMITTED WORK LA N D S C A P E 20 ' - 0 " UNPERMITTED FENCE, REPLACE & BUILD NEW FENCE 7 A2 S. HICKORY ST.S. HICKORY ST. 47.00'47.00'PROPERTY LINEPROPERTY LINE 10 8 . 0 0 ' 10 8 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 10 8 . 0 0 ' 10 8 . 0 0 ' 10 8 . 0 0 ' 10 8 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 10 8 . 0 0 ' 10 8 . 0 0 ' 1929 S HICKORY ST., SANTA ANA, CA 12 ' - 0 " (N ) A D U F R O N T S E T B A C K 20 ' - 0 " 23' - 0" SIDE SETBACK 4' - 0" (E) SINGLE-FAMILY DWELLING (E ) C O N C R E T E D R I V E W A Y 10 8 ' - 0 " 47' - 0" 5' - 0" WM (E) ELECTRIC PANEL TO BE CONVERTED TO (N) SUBPANEL FOR PRIMARY HOUSE (E) WATER METER (E) SEWER LATERAL (E) GRASS (E) GRASS G (E) UNDERGROUND GAS METER (E ) F R O N T S E T B A C K 80 ' - 6 " SEWER TIE IN 2% FIRE SEPARATION DISTANCE LINE 5% 1927 S HICKORY ST (N) ACCESSORY DWELLING UNIT 715 SF 6' - 0 " 6' - 0 " (N) 200 AMP DUAL METER PANEL (N) GARAGE 256 SF 46.00'46.00' 47.00'47.00'PROPERTY LINEPROPERTY LINE 46.00'46.00' (E) MULCH SIDEWALK 17 ' - 0 " 7' - 6 " 43 ' - 6 " 2% 2% 5% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 16' - 11" 20' - 0" 5 A5 5% 5% 23' - 0" 5' - 0" LA N D S C A P E 12' - 0" R 1 4 ' - 4 1 3 / 1 6 " R 18' - 0" R 36 ' - 0" CAR TURNING PATH UNPERMITTED FENCE, REPLACE & BUILD NEW FENCE 7 A2 G WM MAIN PANEL LOCATION GAS METER WATER METER WATER LINE SEWER LINE SITE LEGEND PROPERTY LINE BUILDING LINE (E) GRASS CONCRETE ROOF HATCH GAS LINE ELECTRICAL LINE FIRE SEPARATION DISTANCE LINE EXISTING TREE SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 A1 PROJECT DATA & SITE PLAN 07/09/2024 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U 1929 & 1927 S HICKORY ST., SANTA ANA, CA 92707SCOPE OF WORK: 1. DEMOLISH EXISTING SHED (UNPERMITTED WORK) 2. CONSTRUCT A DETACHED ACCESSORY DWELLING UNIT - 1040 SF, 2 BED, 2 BATH, & WITH 276SF 1-CAR GARAGE AND A 12SF PORCH DATA: OWNER/S : ALAN CHEN PARCEL NUMBER : 949-742-1598 LOT SIZE : 4968 SF ZONE : R1 CONTACT NUMBER : 714-715-1453 EMAIL ADDRESS : alansgc@gmail.com TYPE OF CONSTRUCTION ; V-B OCCUPANCY : R-3 VHFHSZ : NO FLOOD ZONE : X THIS PROJECT SHALL COMPLY WITH THE: 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC) 2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS (CEES) 2022 CALIFORNIA BUILDING CODE (CBC) CODE REQUIREMENTS: THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE INDEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND OR OBTAINPERMIT FROM STATE OF CALIFORNIA, DIVISION OF OCCUPATIONALSAFETY AND HEALTH (CAL/OSHA). THIS PERMIT AND ANY OTHER SAFETYPERMIT SHALL BE OBTAINED PRIOR TO COMMENCE OF ANY WORK. CAL/OSHA NOTE: 1. 2. 3. a. b. c. 65% OF NONHAZARDOUS CONSTRUCTION AND DEMOLITIONDEBRIS SHALL BE SALVAGED, RECYCLED, AND/OR RESUSED. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATERDAMAGAE SHALL NOTE BE INSTALLED.WALL AND FLOOR FRAMING SHALL NOT BE ENCLOSED WHENTHE FRAMING MEMEBERS EXCEED19% MOISTURE CONTENT. INSULATION PRODUCTS WHICH AREVISIBLY WET OR HAVE HIGH MOISTURE CONTENT SHALL BEREPLACED OR ALLOWED TO DRY PRIOR TO ENCLOSURE INWALLOR FLOOR CAVITIES (CGBSC 4.505.3) PROJECTS, WHICH DISTURB LESS THAN 1-ACRE OR SOILD ANDARE NOT PART OF LARGER DEVELOPMENTS THAT DISTURBMORE THAN 1-ACRE, SHALL MANAGE STORM WATER DRAINAGEDURING CONSTRUCTION. THE FOLLOWING MEASURES MAY BEIMPLEMENTED TO PREVENT FLOODING OF ADJACENTPROPERTIES, PREVENT EROSION, AND RETAIN SOIL RUNOFF ONTHE SITE: WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGESYSTEM, COLLECTION POINT, GUTTER, OR SIMILAR DISPOSALMETHOD, WATER SHALL BE FILTERED BY US OF A BARRIERSYSTEM, WATTLE, OR OTHER METHOD APPROVED BY THEENFORCING AGENCY. COMPLIANCE WITH A LAWFULLY ENACTED STORM WATERMANAGEMENT ORDINANCE RETENTION BASINS OF SUFFICIENT SIZE SHALL BE UTILIZEDTO RETAIN STORM WATER ON THE SITE. CALGREEN NOTES: SHEET INDEX NO. SHEET SHEET NAME 1 A1 PROJECT DATA & SITE PLAN 2 A2 EXISTING HOUSE 3 A3 PROPOSED ADU FLOOR & ROOF PLAN 4 A4 PROPOSED ELECTRICAL PLAN 5 A5 ADU ELEVATIONS & SECTION 6 A6 EROSION & SEDIMENT CONTROL PLAN 7 A7 EXISTING & PROPOSED CONTOUR MAP 8 A8 SINGLE FAMILY RESIDENTIAL MANDATORY REQUIREMENTS 9 A9 FRAME BACKING FOR FUTURE GRAB BAR INSTALLATIONS 10 A10 FLOOR AREA RATIO 11 AD.1 ARCHITECTURAL DETAILS 12 AD.2 ARCHITECTURAL DETAILS 13 CG.1 CAL. GREEN REQUIREMENTS 14 CG.2 CAL GREEN REQUIREMENTS 15 S-1 FOUNDATION PLAN 16 S-2 FRAMING PLAN (ADU) 17 SD1 STRUCTURAL DETAILS 18 T24 T24 1. 2. 3. 4. 5. 6. 7. PLANNING CLEARANCE REQUIRED FOR OVERHEADSERVICE LINE. “PV IS A DEFERRED APPROVAL AND BUILDING CANNOTBE OCCUPIED UNTIL PV IS APPROVED BY CITY.” NEW ADU SHALL MATCH EXISTING RESIDENCE ARCHITECTURALSTYLE, BUILDING MATERIALS, WINDOW STYLE, WINDOW FRAMES,ROOFING STYLE, ALL MATERIALS AND DESIGN. RECOMPACT 4’ OVEREXCAVATION PRIOR TO TRENCHING FOR THE UTILITY AND/ORFOUNDATION. 90% COMPACTION REPORT IS REQUIRED AT THE TIME OF FOUNDATIONINSPECTION. DAMP PROOFING, BASE COURSE AND PRE- SATURATION ARE REQUIRED. PROVIDE 5” SLAB ON GRADE REINFORCED WITH #4 AT 18” ON CENTERS EACH WAYOVER 4” BASE OF ½” OR LARGER CLEAN AGGREGATE WITH 10 MIL VAPOR RETARDER INDIRECT CONTACT WITH CONCRETE. SLAB SHALL BE TIED-IN TO CONTINUOUS 12” WIDEX 24” (MINIMUM EMBEDMENT INTO FIRM SOIL) FOUNDATION. CONTINUOUS FOUNDATION MUST BE REINFORCED WITH 2 #5 (OR 3 #4) TOP ANDBOTTOM. ALL CONCRETE SHALL BE FC’=4,500 PSI (MINIMUM) WITH TYPE V CEMENTMAXIMUM WATER CEMENT RATIO OF 0.45. NO SPECIAL INSPECTION REQUIRED IFCONCRETE TRUCK MIX TICKET IS PROVIDED. GENERAL NOTES: JOB LOCATION SUBJECT PROPERTY IS 0.2 MILES TO THE NEAREST BUS STOP AREA LIVING (SF) GARAGE (SF) PORCH (SF) BEDROOM BATHROOM ON-STE PARKING EXISTING 880 0 30 3 1 400 (N) ADU 715 256 12 2 2 TOTAL (EXISTING + ADU) 1595 256 42 5 3 400 LOT COVERAGE 2293 LOT SIZE 4968 % OF LOT COVERAGE 46.16% NOT TO SCALE PROJECT LOCATION SCALE: 1/8" = 1'-0" 1 EXISTING SITE PLAN SCALE: 1/8" = 1'-0" 2 PROPOSED SITE PLAN EXISTING + ADU + GARAGE + PORCH + ON-SITE PARKING N N DIG ALERT (811) TO BE CONTACTED AND THAT COMPLIANCE WITH EXCAVATION SAFETY IN ACCORDANCE WITH THE GOVERNMENT CODE 4216 WILL BE FOLLOWED PRIOR TO ANY EXCAVATION TAKING PLACE. PER THE 2022 CALIFORNIA ENERGY CODE, SECTION 150.1(C)14, ALL NEWLY CONSTRUCTEDNSINGLE FAMILY RESIDENTIAL BUILDINGS INCLUDING NEW DETACHED ACCESSORY DWELLING UNITS (ADU'S) SHALL HAVE A NEWLY INSTALLED SOLAR PHOTOVOLTAIC (PV) SYSTEM. EXCEPTIONEXCEPTION : PER EXCEPTION 2 OF CALIFORNIA ENERGY CODE, SECTION 150.1(C)14, A PHOTOVOLTAIC (PV) SYSTEM IS NOT REQUIRED WHEN THE MINIMUM REQUIRED SIZE OF THE PV SYSTEM IS LESS THAN 1.8kW. THEREFORE, A PHOTOVOLTAIC (PV) SYSTEM IS NOT REQUIRED FOR A SINGLE-FAMILY RESIDENTIAL BUILDING OR AN ADU WITH A FLOOR AREA OF 733 SF OR LESS. RE V I S I O N T A B L E NU M B E R D A T E RE V I S E D B Y DE S C R I P T I O N 715 256SF 12/10/2024 Bldg #102121149-50 APPROVALS: PLNG - H. Jacinto BLDG - G. Huang POLICE - B. Martin PUBLIC WORKS - B. Sarlak 1927 & 1929 S Hickory St2/12/2025 REF SD SD SD CM 11 22 LIVING KITCHEN BEDROOM 1BEDROOM 2 12 ' - 5 " 5' - 5 " 13 ' - 4 " 13 ' - 8 " 5' - 0 " 12 ' - 5 " GARAGE CH: 9'-0"CH: 9'-0"CH: 9'-0"CH: 9'-0" BATH 1BATH 2 CH: 9'-0"CH: 9'-0"CH: 9'-0"CH: 9'-0" CL O . CL O . CLOTHCLOTH W/DW/D 2' - 4"20' - 8" 12 ' - 5 " 12 ' - 5 " 23' - 0" AC 4' - 0 " 3' - 0" 31 ' - 1 " CH: 9'-0"CH: 9'-0"CH: 9'-0"CH: 9'-0" 31 ' - 1 " 43 ' - 6 " 43 ' - 6 " 12 ' - 0 " 20' - 0"AREA TABULATION AREA MARK AREA NAME 1 2 COMMON LIVING AREA BEDROOM AREA DIMENSION 12' 5" X 20' 0" 13' 8" X 23' 0" SQUARE FOOTAGE 287.12 SF 316.24 SF SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 A10 FLOOR AREA RATIO 04/03/24 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N SCALE: 1/4" = 1'-0"1 FLOOR AREA RATIO 1927 & 1929 S Hickory St2/12/2025 4" / 1 2 " 4" / 1 2 " 4" / 12"4" / 12" BEDROOM 2BEDROOM 2 BEDROOM 1BEDROOM 1 BATHBATH BEDROOM 3BEDROOM 3 LIVINGLIVINGKITCHENKITCHEN PORCHPORCH STUCCO E1 EXISTING ASPHALT SHINGLES E1E1 STUCCO E2E1 STUCCO E1 E2 E1 EXISTING ASPHALT SHINGLES STUCCO 3' - 0 " 0' - 4"0' - 4"0' - 4" SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 A2 EXISTING HOUSE 04/10/2024 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U SCALE: 1/4" = 1'-0"1 EXISTING ROOF PLAN SCALE: 1/4" = 1'-0"2 EXISTING FLOOR PLAN SCALE: 1/4" = 1'-0"3 EXISTING WEST ELEVATION N N SCALE: 1/4" = 1'-0"5 EXISTING SOUTH ELEVATION SCALE: 1/4" = 1'-0"4 EXISTING EAST ELEVATION RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N TAG QTY OPERATION WIDTH HEIGHT E1 6 SLIDING 60"48" E2 2 SLIDING 36"36" WINDOW SCHEDULE SCALE: 1/4" = 1'-0"6 EXISTING NORTH ELEVATION SCALE: 1/4" = 1'-0"7 FENCE ELEVATION 1927 & 1929 S Hickory St2/12/2025 REF SD SD SD CM ATTIC VENT CALCULATION AREA VENTILATED 1000.5 SF RATE REQ. VENTS: 150 960.5 SQ.IN TYPE O'HAGING VENT QTY.AREA PER UNIT 9 120 SQ.IN TOTAL AREA PROVIDED 1080 SQ.IN 14"x18" GABLE END VENT 0 110 SQ.IN 0 SQ.IN 24"x12" DORMER VENT 0 100 SQ.IN 0 SQ.IN 2.5" SCREENED 3-HOLE VENTS 0 15 SQ.IN 0 SQ.IN 5.5"x14.5" SOFFIT VENTS 0 65 SQ.IN 0 SQ.IN TOTAL VENTILATION PROVIDED 1080 SQ.IN D5D5 D4 D4 D4 D4 D6 D2 D1 W2 W2 W3 W1 D3 W4W4 W4 D1 WH AC 4' - 0 " 3' - 0" B-B A5 A-A A5 01 06 02 12 10 09 05 15 13 06 02 12 14 03 11 11 04 07 08 1' - 0 " 3' - 0 " 1' - 0 " 2' - 0"5' - 0"2' - 11"2' - 11"5' - 0"2' - 0" 1' - 3 " 3' - 0 " 1' - 2 " 3' - 0 " 1' - 0 " 5' - 0 " 1' - 3 " 2' - 0 " 8' - 0 " 2' - 5 " 4' - 9 " 3' - 0 " 4' - 9 " 2' - 6" 8' - 0"1' - 6" 9' - 8"9' - 2" 2' - 6" 2' - 5 " 2' - 5 " 31 ' - 1 " CH: 9'-0"CH: 9'-0"CH: 9'-0"CH: 9'-0" 1-HOUR FIRE RESISTIVE CONSTRUCTION BETWEEN GARAGE AND DWELLING CONTINOUS FROM FOUNDATION TO ROOF SHEATING 31 ' - 1 " 43 ' - 6 " 43 ' - 6 " 36"X80" (N) SOLID CORE - SELF CLOSING-1HR 11' - 7"11' - 7" 12 ' - 0 " 20' - 0" TEMP TEMP EGRESS EGRESS TEMP 8 AD.2 4" / 12" 4" / 12" 4" / 1 2 " 1' - 0" 1' - 0" NOTE: TO MATCH EXISTING PRIMARY HOUSE ROOFING 1' - 0 " 5 A3 LEGEND O'HAGING VENT BUILDING LINE SLOPE 4" / 12" SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 A3 PROPOSED ADU FLOOR & ROOF PLAN 04/10/2024 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U DOOR SCHEDULE TAG DOOR TYPE OPERATION WIDTH HEIGHT QTY D1 SOLID SWINGING 3' - 0"6' - 8"2 D2 GARAGE DOOR ROLL-UP 8' - 0"7' - 0"1 D3 SOLID SELF CLOSING 1 HR FIRE RATED 3' - 0"6' - 8"1 D4 <varies>SWINGING 2' - 6"6' - 8"5 D5 CLOSET SLIDING 5' - 0"6' - 8"2 D6 CLOSET BIFOLD 4' - 0"6' - 8"1 N 1. 2. 3. THE ATTIC ACCESS SHALL BE A MINIMUM OF 22" X 30". A THIRTY-INCH MINIMUM CLEAR HEAD ROOM SHALL BEPROVIDED ABOVE THE ATTIC ACCESS. ATTIC ACCESS SHALL BE LOCATED AT A READILY ACCESSIBLE LOCATION MECHANICAL VENTILATION IS NOT LESS THAN 6 AIR CHANGES PER HOUR TYPE. THE POINT OF DISCHARGE OFEXHAUST AIR SHALL BE AT LEAST 3 FEET FROM ANY OPENING INTO THE BUILDING. THE EXHAUST VENT SHALL BEEQUIPPED WITH BACK-DRAFT DAMPER TO COMPLY WITH ENERGY REGULATIONS. PROVIDE OUTDOOR COMBUSTION AIR OPENINGS FOR THE MECHANICAL CLOSET WITH THE 2 PERMANENT OPENINGSMETHOD PER CMC SECTION 701.4.1. ONE OPENING SHALL COMMENCE WITHIN12 INCHES OF THE TOP AND THE OTHERCOMMENCING WITHIN 12 INCHES OF THE BOTTOM OF THE ENCLOSURE VENTILATION NOTES: A. B. C. PROVIDE NO LESS THAN 30% UPPER VENTS. BE INSTALLED ON VERTICAL ATTIC SURFACES AND GABLE ENDS. WHEN INSTALLED IN ENCLOSED RAFTER SPACES A MINIMUM AIR SPACE OF 1" MUST BE PROVIDED AND VENTILATIONBE PROVIDED AT UPPER AND LOWER END OF EVERY RAFTER BARRIER. RADIANT BARRIER INSTALLATION SHALL COMPLY WITH THE FOLLOWING: 1. 2. 3. 4. 5. 6. 7. SAFETY OR TEMPERED GLAZING REQUIRED IN THE FOLLOWING LOCATIONS: GLAZING IN ENCLOSURES FOR OR WALLFACING HOT TUBS, WHIRLPOOLS, BATHTUBS AND SHOWERS WHERE THE BOTTOM EXPOSED EDGE IS LESS THAN 60INCHES MEASURED VERTICALLY AVOVE A STANDING OR WALKING SURFACE (CRC R308.4) CEMENT, FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT GYPSUM OR FIBER-REINFORCED GYPSUMBACKERS SHALL USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS INSHOWER AREAS. (R702.4.2 CRC) SHOWERS AND TUB-SHOWER COMBINATION VALVES SHALL BE EQUIPPED WITH A MEANS TO LIMIT THE MAXIMUMSETTING OF THE VALVE TO 120 DEGREES F (CPC 408.3) NEW ADU SHALL MATCH EXISTING RESIDENCE ARCHITECTURALSTYLE, BUILDING MATERIALS, WINDOW STYLE, WINDOW FRAMES,ROOFING STYLE, ALL MATERIALS AND DESIGN. VENT OPENINGS SHALL BE PROVIDED WITH CORROSION-RESISTANT WIRE MESH WITH 1/16" MINIMUM TO 1/4" MAXIMUMOPENINGS. A MINIMUM OF A 1-INCH AIRSPACE MUST BE MAINTAINED BETWEEN THE INSULATION AND THE ROOF SHEATHING ATTHE LOCATIONS OF THE VENTS. [CRC R806] BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT, DUCTED TO TERMINATE OUTSIDE THEBUILDING, AND CONTROLLED BY A HUMIDISTAT CAPABLE OF BEING ADJUSTED BETWEEN THE RELATIVE HUMIDITYRANGE OF 50 TO 80 PERCENT. [CGBC 4.506] WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED EQUAL TO 72 INCHES ABOVE DRAIN AT SHOWERSOR TUB WITH SHOWERS. MATERIALS OTHER THAN STRUCTURAL ELEMENTS ARE TO BE MOISTURE RESISTANT. [CRCR307.2] NOTES:SCALE: 1/4" = 1'-0"1 PROPOSED FLOOR PLAN SCALE: 1/4" = 1'-0"2 PROPOSED ROOF PLAN N KEYNOTESKEYNOTES 01 DRYER; A) PROVIDE 4" DIA. SMOOTH METAL DUCT FOR DRYER EXHAUST EXTENDING TO OUTSIDE W/ BACK DRAFT DAMPER (36" MIN. AWAY FROM OPENING). ;B) MAX. VENT DUCT LENGTH OF 14'. ;C) DOOR AT LAUNDRY ROOM MUST BE LOUVERED TO ALLOW DRYERS TO HAVE SUFFICIENT MAKE-UP AIR.;D) THE SPECIFICATION WILL BE ON A DEFERRED SUBMITTAL. :E) THE DRYER MOISTURE EXHAUST DUCT TO BE METAL OR MOISTURE RATED PVC WITH A SMOOTH INTERIOR SURFACE W/O SCREWS. 02 MINIMUM SHOWER SIZE 1,024 SQ. IN. WITH NO LESS THAN 30" IN ANY DIRECTION (MUST ENCOMPASS A 30" CIRCLE). SHOWER DOORMIN. 22" WIDE, TEMPERED. WATER CLOSET MUST BE CENTERED IN A 30" CLEAR SPACE AND MUST HAVE A 24" CLEAR IN FRONT. FLOORS AND WALL SHALL BE FINISHED WITH A NONABSORBENT SURFACE, SUCH WALL SURFAVES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. 03 22" x 30" ATTIC ACCESS, WITH 30-INCHES MINIMUM CLEAR UNOBSTRUCTED HEADROOM ABOVE THE CEILING. (CRC R807). 04 EXTERIOR LANDING AT THE EXTERIOR DOOR SHALL BE A MAXIMUM OF 7-3/4" BELOW THE TOP OF THE THRESHOLD, PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR. 05 NO DISHWASHING MACHINE SHALL BE DIRECTLY CONNECTED TO A DRAINAGE SYSTEM OR FOOD WASTE DISPOSER WITHOUT THE USE OF AN APPROVED DISHWASHER AIR GAP FITTING ON THE DISCHARGE SIDE OF THE DISHWASHING MACHINE. LISTED AIR GAPS SHALL BE INSTALLED WITH THE FLOOD-LEVEL (Fl0 MARKING AT/ ABOVE THE FLOOD LEVEL OF THE SINK OR DRAIN BOARD, WHICHEVER IS HIGHER. CPC SEC.807.3 06 CONTINUOUS REINFORCING BACKING FOR FUTURE GRAB BARS. CRC SECTION R327.1.1 ;A) REINFORCEMENT SHALL BE A MINIMUM OF 2X8 SOLID LUMBER AND SHALL BE LOCATED BETWEEN 32 INCHES AND 39-1/4 INCHES ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. ;B) WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. EXEMPTION #1: WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR -MOUNTED FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY.; C) INFORMATION AND/ OR DRAWINGS IDENTIFYING THE LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION AND MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE. CHAPTER 4. DIVISION 4.4 CRC SECTION R3271.1.1.; D) SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE FRAMING IS PROVIDED.; D) REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PRE-FABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS WITH INTEGRAL FACTORY-INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. EXCEPTION #2. ;E) SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/ OR GRAB BARS SHALL BE PERMITTED, PROVIDED REINFORCEMENTS FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. EXCEPTION #3. 07 AIRCONDITIONER OUTDOOR UNIT 08 50-GAL ELECTRIC HEAT PUMP WATER HEATER WITH PRESSURE WATER RELIEF VALVE WITH DRAIN OUTSIDE WATER HEATER. CPC 504.6. SE DETAIL 1 2/AD.1.ELECTRIC WATER HEATER, SPECIFICATIONS PER ENERGY DOCUMENTATION 09 LOCAL EXHAUST VENTILATION HOOD, MIN. 100 CFM 10 REFRIGERATOR SPACE W/ COLD WATER STUB-OUT FOR ICEMAKER (VERIFY SIZE W/ MNFR) 11 30" x 60" TUB/SHOWER W/ CURTAIN ROD, IMPERVIOUS SURROUND ON 3 WALLS +7'-0" (MIN. 72"). 12 LAVATORY SINK [CPC TABLE 422.1] [PENETRATIONS IN WALL LINE (I) SHALL COMPLY WITH CRC R302.4] 13 KITCHEN CABINET LAYOUT BY OWNER/CONTRACTOR 14 ELECTRIC PANEL 15 KITCHEN SINK W/ GARBAGE DISPOSAL (SEE CALGREEN SHEET FOR MAX FLOW RATE) WINDOW SCHEDULE TAG QTY TYPE/OPERATION MATERIAL WIDTH HEIGHT HEAD HEIGHT W1 1 SLIDING VINYL FRAME W/ LOW E-DOUBLE PANE GLASS (TEMPERED) 5' - 0"4' - 0"6' - 8" W2 2 SLIDING VINYL FRAME W/ LOW E-DOUBLE PANE GLASS (TEMPERED) 3' - 0"1' - 0"6' - 8" W3 1 SLIDING VINYL FRAME W/ LOW E-DOUBLE PANE GLASS3' - 0"3' - 0"6' - 8" W4 3 SLIDING VINYL FRAME W/ LOW E-DOUBLE PANE GLASS5' - 0"4' - 0"6' - 8" RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N 1927 & 1929 S Hickory St2/12/2025 LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. 3 A5 1 A5 4 A5 14 ' - 3 " 4' - 7 " 9' - 0 " 0' - 8 " HALLHALL LIVINGLIVING GARAGEGARAGE SLAB ON GRADE R-10 INSULATION 1/2" GYPSUM BOARD R-30 INSULATION R-0 INSULATION R-15 INSULATION LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. ASPHALT SHINGLE CLASS "A" OVER #30 FELT. OWENSCRONIGN ROOFING ASPHALT ESR # 1372. INSTALLATIONOF ROOFING SHALL BE IN ACCORDANCE WITHMANUFACTURER'S SPECIFICATIONS (TYP.)RIDGE BEAM STRUCTURAL 5 A5 1 A5 2 A5 R-10 INSULATION 1/2" GYPSUM BOARD R-30 INSULATION 3 A5 14 ' - 3 " 9' - 0 " 4' - 7 " 0' - 8 " LIVINGLIVINGKITCHENKITCHEN 1-HR FIRE RATED WALL R-15 INSULATION LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. 3 A5 5 A5 4:12 SLOPE ASPHALT SHINGLE CLASS "A" OVER #30 FELT. OWENSCRONIGN ROOFING ASPHALT ESR # 1372. INSTALLATIONOF ROOFING SHALL BE IN ACCORDANCE WITHMANUFACTURER'S SPECIFICATIONS (TYP.) TOP OF WINDOW STUCCO TYP. 14 ' - 3 " 4' - 7 " 9' - 0 " 0' - 8 " 2' - 4 " 6' - 8 " 1-HR FIRE RATED WALL SI L L H E I G H T 40 " SI L L H E I G H T 40 " LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. 3 A5 3 A5 4:12 SLOPE ASPHALT SHINGLE CLASS "A" OVER #30 FELT. OWENSCRONIGN ROOFING ASPHALT ESR # 1372. INSTALLATIONOF ROOFING SHALL BE IN ACCORDANCE WITHMANUFACTURER'S SPECIFICATIONS (TYP.) STUCCO TYP. 14 ' - 3 " 4' - 7 " 9' - 0 " 0' - 8 " TOP OF WINDOW2' - 4 " 6' - 8 " LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. 3 A5 3 A5 4:12 SLOPE ASPHALT SHINGLE CLASS "A" OVER #30 FELT. OWENSCRONIGN ROOFING ASPHALT ESR # 1372. INSTALLATIONOF ROOFING SHALL BE IN ACCORDANCE WITHMANUFACTURER'S SPECIFICATIONS (TYP.) STUCCO TYP. 14 ' - 3 " 4' - 7 " 9' - 0 " 0' - 8 " TOP OF WINDOW2' - 4 " 6' - 8 " LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. TOP OF WINDOW 6' - 8 " 5 A5 3 A5 4:12 SLOPE ASPHALT SHINGLE CLASS "A" OVER #30 FELT. OWENSCRONIGN ROOFING ASPHALT ESR # 1372. INSTALLATIONOF ROOFING SHALL BE IN ACCORDANCE WITHMANUFACTURER'S SPECIFICATIONS (TYP.) STUCCO TYP. 14 ' - 3 " 0' - 8 " 9' - 0 " 4' - 7 " 6' - 8 " 2' - 4 " AC OUTSIDE UNIT 1-HR FIRE RATED WALL INTERIOR FINISH 2X WALL STUDS SILL PLATE, PRESSURE TREATED CONC. SLAB 10 ML POLY VAPOR DIFFUSION RETARDER IS EXTENDED UNDER FOOTING 4" THICK BASE OF 1/2" OR LARGER CLEAN AGGREGATE R-15 INSULATION PLYWOOD SHEATHING PER STRUCT. MIN 5/8" CDX EXTERIOR FINISH 26 GAGE WEEP SCREED 2" M I N AT P A V E D 6" M I N 8" M I N FINISH GRADE CONTINUOU RIDGE VENT 24 GA. RIDGE FLASHING UNDERLAYMENT W/ 12" MIN. OVERLAP RIDGE BOARD, SEE STRUCTURAL SHEETS ROOF RAFTER, SEE STRUCTURAL SHEETS INSULATION (IF REQUIRED) ASPHALT SHINGLE, LAND MARK, ICC-ES- ESR-1389 & ESR-3537 ROOF UNDERLAYMENT ROOF SHEATHING NOTE: PROVIDE EITHER 1" MINIMUM CLEARANCE BETWEEN INSULATION AND ROOF SHEATHING OR USE INSULATION BAFFLE FOR RAFTER SPACE VENTILATION ROOF RAFTER, SEE STRUCTURAL SHEETS ROOFING 2 LAYERS 30# FELT OVER PLYWOOD SHEATHING 2x BLOCK ROOF FASCIA EXTERIOR FINISH INSULATION 2x CEILING JOIST DBL TOP PLATE 2X WALL STUDS 3/ 4 " T Y P . NON-BRG. WALL 1X OVER 2X PLATE 3/ 4 " T Y P . TRUSS WHERE OCCURS PER PLAN SIMPSON "DTC" @ 48" OC MAX. 2X BLK'G. @ 48" O.C. W/ (3) 16d'S @ EA. END JOIST OR TRUSS BOTT. CHORD RAFTER CEILING JOIST 7/8" STUCCO UNDER EAVE NO EAVE VENTS PERMITTED 7/8" STUCCO INSULATION PER PLAN 2x4 STUD WALL 5/8" TYPE "X" GYPSUM BOARD SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 A5 ADU ELEVATIONS & SECTION 04/10/2024 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U 1. A. B. C. 2. ALL EXTERIOR WALL ASSEMBLIES SHALL INCLUDE: TWO LAYERS OF GRADE D OR 60 MINUTE GRADE D PAPER APPLIED OVER ALL WOOD BASE SHEATHING. (CRC R703.7.3 & R703.2). A MINIMUM 0.019 INCH (NO. 26 GALVANIZED SHEET GAGE) CORROSION-RESISTANT WEEP SCREED. (CRC 703.1.1 & R703.7.2.1) THE SCREED SHALL BE INSTALLED WITH THE WEEP OPENINGS LOCATED A MINIMUM 1 INCH BELOW FOUNDATION PLATE LINE AND 4INCHES ABOVE FINISH GRADE OR 2-INCHES ABOVE PAVED AREAS.(CRC R703.1.1 & R703.7.2.1) -ASPHALT ROOF SHINGLES "WEATHER WATCH" ICE &WATER SHIELD AS 30# FELT PAPER MANUFACTURED BYGAF OR EQUAL. INSTALL AS PER MANUFACTURER'SSPECIFICATIONS 1/2" OSB PLYWOOD SHEATHING ( TOMATCH WITHIN EXISTING ROOF/ MATERIAL % COLOR), TYP.OWENS CORNING ROOFING ASPHALT ESR # 1372.CRRC PRODUCT ID # 0890-0013 EXTERIOR CONSTRUCTION ASSEMBLY PLASTER WEEP SCREED NTS 1RIDGE DETAIL NTS 2EAVE DETAIL NTS 3NON-BEARING WALL DETAIL NTS 4FIRE-RATED EAVE DETAIL NTS 5 SCALE: 1/4" = 1'-0"6 SECTION B-B SCALE: 1/4" = 1'-0"3 SECTION A-A SCALE: 1/4" = 1'-0"1 WEST ELEVATION SCALE: 1/4" = 1'-0"5 NORTH ELEVATION SCALE: 1/4" = 1'-0"4 SOUTH ELEVATION SCALE: 1/4" = 1'-0"2 EAST ELEVATION RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N 1927 & 1929 S Hickory St2/12/2025 SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 A8 SINGLE FAMILY RESIDENTIAL MANDATORY REQUIREMENTS 04/03/24 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N 1927 & 1929 S Hickory St2/12/2025 SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 A9 FRAME BACKING FOR FUTURE GRAB BAR INSTALLATIONS 04/03/24 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N 1927 & 1929 S Hickory St2/12/2025 SOLID BACKING HEADER ROUGH OPENING JAMB SILL SILL FLASHING HEADER JAMB SILL ROUGH OPENING 2" CONTINUOUS BEAD OF SEALANT UNDER NAILING FLANGE. HEAD FLASHING WINDOW FRAMING OR SIMILAR OPENING LINE OF NAILING FLANGE BUILDING PAPER TYP. WINDOW FRAME OR SIMILAR OPENING CUT AWAY EXCESS BLDG. PAPER AT OPENING 4" M I N . BUILDING PAPER UNDER SILL STRIP STEP 4: STEP 3: STEP 2: STEP 1: · ATTACH SILL STRIP OF 9" WIDE VYCOR V40 WEATHER BARRIER STRIP WITH TOP EDGE EVEN WITH THE TOP OF THE ROUGH SILL. · PROVIDE SOLID BACKING AT ALL AREAS WHERE FLASHING MATERIAL LAPPING WILL OCCUR. · EXTEND THIS STRIP AT LEAST 11" BEYOND THE EDGE OF THE ROUGH OPENING. · ATTACH FLASHING MATERIAL WITH GALVANIZED ROOFING NAILS OR CORROSION- RESISTANT STAPLES. · ATTACH JAMB STRIPS OF 9" WIDE MOISTOP FLASHING MATERIAL WITH INSIDE EDGE EVEN WITH THE JAMB OF THE ROUGH OPENING. · START JAMB STRIPS 2" BELOW SILL STRIP AND EXTEND 4" ABOVE LOWER EDGE OF HEADER. · APPLY A CONTINUOUS BEAD OF SEALANT TO THE BACK OF THE FRAME NAILING FLANGE · PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE INSTALLED JAMB AND SILL MOISTOP FLASHING MATERIAL. · APPLY AN ADDITIONAL LAYER OF 9" WIDE VICOR V40 WEATHER OVER THE JAMB NAILING FLANGE. · ATTACH 9" WIDE VYCOR V40 WEATHER BARRIER STRIP OVER THE HEAD FLANGE. EXTEND THIS STRIP 2" BEYOND THE OUTER EDGE OF THE JAMB FLASHING MATERIAL. -STARTING FROM THE BASE OF THE WALL, APPLY BUILDING PAPER UNDER THE SILL STRIP AND CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND ABOVE THE SILL AND BETWEEN THE JAMBS OF THE OPENING. -APPLY THE NEXT COURSE OF BUILDING PAPER (BUTTING TO THE FRAME OPENING) OVER THE JAMB FLASHING MATERIAL. -APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE BOARD FASHION UP THE WALL, LAPPING COURSES A MINIMUM OF 6". 1.SECTION 1402 OF THE 2019 EDITION OF THE U.B.C. STATES "EXTERIOR OPENINGS EXPOSED TO THE WEATHER SHALL BE FLASHED IN A MANNER AS TO MAKE THEM WEATHERPROOF." THE PROCEDURE ABOVE IS RECOMMENDED TO ACHIEVE THIS INTENT FOR THE FLASHING OF WALL OPENINGS TO INCLUDE BUT NOT LIMITED TO: WINDOWS, DOORS, VENTS, ETC. 2.ALL MATERIALS SHALL BE IN STRICT CONFORMANCE WITH U.B.C. STANDARD 14-1 3.APPLICATION OF FINISH MATERIALS OVER FLASHING MATERIALS SHOWN SHALL BE AS SPECIFIED BY CODE REQUIREMENTS, MANUFACTURER'S INSTRUCTIONS AND THE BEST PRACTICES OF THE TRADE. 4.ADDITIONAL MATERIALS, ie. METAL HEAD FLASHING, ELASTOMERIC SHEET WATERPROOFING ETC. MAY OCCUR, DEPENDING ON THE SPECIFIC FINISH MATERIALS BEING USED. REFER TO INDIVIDUAL DETAILS FOR ADDITIONAL INFORMATION. NOTES: 4" 4" 4" 4" 4" 3" 4" 4" 4" 4"G.S.M. 3/ 8 " G.S.M. FLASHING FLANGE SOLDER ALL SEAMS SLOPE TOP 1/8" PER/ 12" G.S.M. FLASHING COLLAR, SEE SPECIFIC APPLICATION DETAIL FOR FURTHER INFO. FLASHING FIN AT WOOD MEMBERS, SEE SPECIFIC APPLICATION DETAIL RECTANGULARRECTANGULAR DRIP / INTERLOCKDRIP / INTERLOCK G.S.M. FLASHING FLANGE SOLDER ALL SEAMS G.S.M. FLASHING COLLAR, SEE SPECIFIC APPLICATION DETAIL FOR FURTHER INFO. ROUNDROUND SEE PLANS FOR SPECIFIC PENETRATION SIZE 26 GA 1-PIECE GSM PAN FLASHING SOLDIER ALL JOINTS ISOMETRIC (PARTIAL) WEATHERSHIP BASE ADJUSTABLE ALUM. CLAD THRESHOLD ONE-PIECE SOLDIERED SHEET MTL. PAN FLASHING 2x PTDF SLEEPER (ATTACH PER S.D.) 1x2 CEDAR TRIM SEE 1/AD. 1 FOR ADDITIONAL FLASHING INFO. HARDSCAPE SLAB SLOPE4" U O N BUILDING SLAB 3/ 8 " - 3 / 4 " FINISH FLR. DR. FRAME BEYOND DOOR 6" 4" V.I.F. 2" M I N . 1/ 2 " PRESSURE RELIEF VALVE/ DRAIN ENDS OUTSIDE =6" FROM GRD. SOLID BLOCKING. 5/8" GYPSUM BOARD1/4" x 3" MIN. LAG SCREW INTO LEDGER W/ 2x4 WOOD LEDGER WASHER 3/4"x24 GAUGE PERFORATED STEEL PLUMBERS TAPE MIN. 1" 6" MIN . HOT COLD T&P VALVE2x4 WOOD LEDGER OVERFLOW WATERTIGHT PAN W/ 1" DRAIN TO PREVENT LEAKAGE FU L L H E I G H T SEISMIC BRACE SEISMIC BRACE WATER HEATER 4 " UP P E R 1 / 3 LO W E R 1 / 3 18 " MI N . PLATFORM. MUST SUPPORT WATER HEATER ON ITS OWN FEET FINISH FLOOR GAS MIN. CLR. PROVIDE 2 STRAPS THE UPPER 1/3 AND LOWER 1/3 OF THE WATER HEATER OVERALL HEIGHT. PER CPC 510.5 GYPSUM BOARD, 1" MIN. THK. 1/4"X5" MIN. LAG SCREW INTO STUDS W/ WASHER. 4" ELASTOMERIC SHEET WATERPROOFING EXTEND AS NOTED SLOPE METAL FLASHING WITH DRIP EXTEND 4" MIN ABOVE CEDAR WOOD TRIM PER ELEVATION WINDOW FRAME WINDOW FRAME SEALANT WOOD TRIM PER ELEVATION ELASTOMERIC SHEET WATERPROOFING EXTEND AS NOTED DBL 2x SILL 2x BLOCKING OMIT AT PLYWD. SHEARWALL GYP. BD. GYP. BD. HEADER PER PLAN HEAD SILL 0' - 6 " WALL SHEATHING PER PLAN, TYP. 2X4 DF#2 @ 16 TYP. OC 2X SILL DF#2 P.T.D.F. SILL PLATE W/ ANCHOR BOLTS PER AB SCHEDULE S.S.D. ONE POUR 12" MAT SLAB S.S.D. NATURAL UNDISTURBED GRADE #4 @ 18" O.C.E.W. S.S.D. HORIZONTAL SIDING WOOD OVER WATER-RESISTIVE BARRIER INSTALLED PER [R703.5.3] WOOD SIDING OPTIONWOOD SIDING OPTION EXTERIOR PLASTER (STUCCO) OVER CORROSION-RESISTANT LATH OVER (2) LAYERS OF WATER- RESISTIVE BARRIER INSTALLED PER [R703.7] STUCCO OPTIONSTUCCO OPTION CORROSION RESISTANT WEEP SCREED [R703.7.2.1] 2X PRESSURE TREATED SILL PLATE0' - 8 " 1' - 0 " WARM AIR FURNACES INSTALLED IN ATTICS OR FURRED SPACES SHALL BE INSTALLED AS PER UMC 307.3 AND SHALL INCLUDE THE FOLLOWING: 1. A MINIMUM 30"X30" ACCESS (20 FEET MAXIMUM FROM FURNACE) 2.CONTINUOUS SOLID FLOORING (5/8" CDX OR EQ.) 24" MIN. WIDE FROM ACCESS TO FURNACE 3.A LEVEL WORKING PLATFORM 30" MIN. IN DEPTH ALONG THE ENTIRE FIREBOX SIDE OF FURNACE 4. A PERMANENT 110V ELECTRICAL OUTLET AND LIGHTING FIXTURE LOCATED AT OR NEAR FURNACE LIGHTING FIXTURE TO BE CONTROLLED BY A SWITCH LOCATED AT ACCESS. 5.THE FAU SHALL BE LISTED FOR INSTALLATION IN ATTICS AND ON COMBUSTIBLE FLOORING. CLEARANCES SHALL BE AS PER MANUFACTURER'S SPECIFICATIONS AND PER UBC 304. 22" M I N 30" M I N 30" 24" 24" 4 1 2 4 3 5 NOTE: TRUSS DESIGN BY TRUSS MFR. SEE DET. 12/ADI FOR ADDITIONAL INFO. NOTE: VERIFY LENGTH OF PLATFORM W/ HVAC CONTRACTOR SEE DETAIL 12/AD I FOR ADDITIONAL REQUIREMENTS PER UMC 319 1.FRAMING SPAN O/ MIN. 3 TRUSSES, S.S.D. 2.3/4" PLYWD. 3.3/8" GYPSUM BD. AT CEILING F.A.U. 30" X 30" CLR. ACCESS AREA FAU CONTROLS 5'-0" MIN. SEE PLAN 10" CLR. MIN. 3 1 2 PROVIDE POSITIVE ELECTRICAL DISCONNECT (SEE SECT. NEC 503) LIGHT OVER CONTROLS (SECT. 309 ASO REQUIRES CONVENIENCE OUTLET (RECEPTACLE) WITHIN 25' OF EQUIP..) 24" WIDE SOLID FLOORING ACCESS WAY RELATED CODES SECTIONS: UMC 307.3 CENTRAL WARM AIR FURNACES INSTALLED IN THE ATTIC MUST BE ACCESSIBLE FOR ROUTINE INSPECTION AND MAINTENANCE BY THE OWNER, OCCUPANT AND FOR SERVICE AND REPAIR AS NEEDED. CHANGING FILTERS, LUBRICATING MOTOR AND FAN BEARINGS, CHECKING BELT TENSIONS AND RELIGHTING THE PILOT FOLLOWING A SERFICE INTERRUPTION ARE NORMAL OWNER FUNCTIONS. ADEQUATE LIGHT, AND ELECTRICAL OUTLET, SAFE ACCESS WAY AND SUFFICIENT WORKING SPACE ON THE CONTROL SIDE ALL ENCOURAGE AND FACILITATE MAINTENANCE AND ENABLE RAPID EGRESS IN AN EMERGENCY. ACCESS OPENING MIN. 22"X30" OR DIMENSION OF APPLIANCE LIGHT SWITCH 20'-0" MAX. WARM AIR FURNACE WORKING SPACE AT CONTROLS MAX 20'-0" -- MI N . C L R . 30 " - MIN . 0' - 6 " 2' - 6" HOUSE-R3 1/2" GYPCO. BD. AT INTERIOR OF HOUSE 2X4 (MIN) STUDS AT 16" O.C. (FIRE WALL) 5/8" TYPE "X" GYP. BD. O/ 2X4 FRAME (FRAME PANEL ON FOUR SIDES) 5/8" TYPE "X" GYP.BD. O/ INT. OF GARAGE, TYP. ELECTRIC SUB- PANEL GARAGE - UI AT GARAGE WALL HOUSE - R35/8" TYPE "X" GYP. BD. AT 1-HOUR OCC. SEP. WALL, W.O. 2X4 (MIN.) STUBS AT 16" O.C. (FIRE WALL) 1/2" GYP. BD. O/ 2X4 FLAT FRAME WALL (FRAME PANEL ON FOUR SIDES) ELECTRIC SUB-PANEL HOUSE - R3 AT INTERIOR WALL ELECTRICAL SUB-PANEL ELEVATION 1' - 0 " 2' - 6 " 5' - 4 " ( N T S ) 3 ' - 7 " - CE I L I N G H T . P E R P L A N - TO.S. SCALE: 1" = 1'-0"1 FLASHING AT OPENINGS SCALE: 1" = 1'-0"2 TYPICAL PENETRATION FLASHING SCALE: 1" = 1'-0"3 INSWINGING DOOR SILL AT SLAB SCALE: 1" = 1'-0"4 WATER HEATER SEISMIC BRACE SCALE: 1" = 1'-0"6 TYPICAL HEAD & SILL DETAIL SCALE: 1" = 1'-0"7 EXTERIOR WALL FOOTING SCALE: 1" = 1'-0"9 ACCESS FURNACE AT ATTIC SCALE: 1" = 1'-0"10 FAU PLATFORM SCALE: 3/16" = 1'-0"8 FURNACE AT ATTIC SCALE: 3/4" = 1'-0"5 ELECTRICAL SUB-PANEL SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 AD.1 ARCHITECTURAL DETAILS 04/03/24 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N 1927 & 1929 S Hickory St2/12/2025 PLYWOOD SHEATHING, SSD LAP UNDERLAYMENT MIN. 6" AT RIDGE W/ I CONT. PIECE OF UNDERLAYMENT AT RIDGE S-TILE ROOF TRUSSES, SSD STUD WALL OPERABLE WINDOW EXTERIOR WALL CEILING NOT MORE THAN 44" ABOVE FLOOR ON THE FINISHED SILL HEIGHT 24 " M I N . C L E A R OP E N I N G H E I G H T FLOOR 20" CIR. MINIMUM PLAN VIEW SECTION VIEW 5/8" GYPSUM BOARD WOOD HEADER - SEE STRUCTURAL WOOD CASING, BY OTHERS DOOR, BY OTHERS WOOD DOOR FRAME SHIM, AS REQUIRED 5/8" TYPE "X" GYPSUM BOARD 5/8" GYPSUM BOARD (2) 2X4 WOOD JAMBS WOOD CASING, BY OTHERS DOOR, BY OTHERS WOOD DOOR FRAME SHIM, AS REQUIRED GYP. BD RADIUS CORNER - USE PLASTIC CORNERS AT WET AREAS GYP. BD SEE PLAN FOR FRAMING 2S/1P 1S/2P SHELF POLE SE E P L A N 3' - 0 " 3' - 0 " SE E P L A N 1' - 0 " 0' - 3 " 5' - 6 " 2X4 P.T. CURB ANCHORED TO SLAB 3/8" ANCHOR BOLTS AT 12" O.C., 6" AT ENDS MORTAR BED-SET CERAMIC TILE SLOPE TILE TO DRAIN AT 1/4" PER FOOT HOT MOP SLOPE TO DRAIN AT 1/4" PER FOOT (E) CONCRETE SLAB GYPSUM WALLBOARD, RESILIENT CHANNELS,GYPSUM WALLBOARD, RESILIENT CHANNELS, MINERAL FIBER INSULATION, WOOD STUDSMINERAL FIBER INSULATION, WOOD STUDS RESILIENT CHANNELS 24" O.C. ATTACHED AT RIGHT ANGLES TO ONE SIDE OF 2X4 WOOD STUDS 16" OR 24" O.C. WITH 1 1/4" TYPE "S" DRYWALL SCREWS. ONE LAYER 5/8" PROPRIETARY TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED PARALLEL TO CHANNELS WITH 1" TYPE "S" DRYWALL SCREWS 12" O.C. END JOINTS BACKBLOCKED WITH RESILIENT CHANNELS. 3" MINERAL FIBER INSULATION, 2.0 OR 2.3 pcf, IN STUD PACE. OPPOSITE SIDE: ONE LAYER 5/8" PROPRIETARY TYPE "X" GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO STUDS WITH 1 1/4" TYPE "W" DRYWALL SCREWS 12" O.C. VERTICAL JOINTS STAGGERED 48" ON OPPOSITE SIDES. SOUND TESTED WITH STUDS 16" O.C. AND OPEN FACE OF MINERAL FIBER INSULATION BLANKETS TOWARD RESILIENT CHANNEL-SIDE OF STUD SPACE. (LOAD BEARING) GA FILE NO. WP 3241GA FILE NO. WP 3241 PROPRIETARYPROPRIETARY THICKNESS:53/8" APPROX. WEIGHT:7 pst FIRE TEST:BASED ON UL R3660-7, 11-12-87; UL R27117-61, 8-18-87; UL R7094, 10-24-90; UL DESIGN U311 SOUND TEST:ESTIMATED 1-HR FIRE1-HR FIRE 50 TO 54 STC SOUND50 TO 54 STC SOUND PROPRIETARY GYPSUM BOARDPROPRIETARY GYPSUM BOARD AMERICAN GYPSUM COMPANY:5/8" FIREBLOC TYPE "C" BPB AMERICA INC.:5/8" PROROCTM TYPE C GYPSUM PANELS G-P GYPSUM:5/8" TOUGHROCK R FIREGUARD R C LAFARGE NORTH AMERICA INC.:5/8" FIRECHECK R TYPE C NATIONAL GYPSUM COMPANY:5/8" GOLD BOND R BRAND FIRE-SHIELD CTM GYPSUM WALLBOARD PABCO GYPSUM:5/8" FLAME CURB R SUPER 'C' TEMPLE-INLAND FOREST PRODUCT CORPORATION:5/8" TG-C SCALE: 1" = 1'-0"6 TYPICAL AT RIDGE SCALE: 1" = 1'-0"4 EMERGENCY EGRESS DETAIL SCALE: 3" = 1'-0"2 TYP. WOOD FRAME INTERIOR DOOR HEAD SCALE: 3" = 1'-0"3 TYP. WOOD FRAME INTERIOR DOOR JAMB SCALE: 3" = 1'-0"5 ROUND GYPSUM BOARD CORNER SCALE: 1/2" = 1'-0"7 CLOSET SHELVING SCALE: 3" = 1'-0"1 CURB AT SHOWER ENTRY SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 AD.2 ARCHITECTURAL DETAILS 04/03/24 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N SCALE: 3/8" = 1'-0"8 1 HR FIRE RATED WALL DETAIL 1927 & 1929 S Hickory St2/12/2025 2 8'-0" 4x 4 HD U 2 4x 4 HD U 2 5/8" AB @32" O.C 2 4'-0" 4x 4 HD U 2 4x 4 HD U 2 5/8" AB @32" O.C 2 8' - 0 " 4x4HDU2 4x4 5/ 8 " A B @3 2 " O . C HDU2 2 4' - 0 " 4x4HDU2 4x4 5/ 8 " A B @3 2 " O . C 8'-0" 4x 4 HD U 2 4x 4 HD U 2 5/8" AB @32" O.C 2 12 ' - 0 " 4x4HDU2 5/ 8 " A B @3 2 " O . C 4x4HDU2 1 SD11 1 SD11 1 2 SD1 1 SD11 1 SD1 1 1 SD1 1 1 SD1 1 20 SD13 2 12 SD1 TYP 4x4 PBS44 4x4 PBS44 19 SD1 1 19 SD1 1 2 SD11 2 2 2 2 1' - 5" 4x4HDU2 4x4HDU2 5/ 8 " A B @3 2 " O . C 2 4' - 0 " LEGENDS : DETAIL SHEAR WALL NAME SHEAR WALL LENGTH NEW FOOTING EXISTING FOOTING X L=X X-X X SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 S-1 FOUNDATION PLAN 04/03/24 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U SCALE: 1/4" = 1'-0"1 PROPOSED FOUNDATION PLAN RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N FOUNDATION PLAN NOTES: (N) CONTINUOUS FOOTING 12" WIDTH X 24" DEEP W/(2) #5 REBAR AT TOP AND (2)#5 BOTTOM. (N) NEW 5" CONCRETE SLAB WITH #4 REBAR @16" O.C. OVER 10MIL VISQUEEN OVER 4" BASE OF 1/2" OR LARGER CLEAN AGGREGATE OVER COMPACTED SOIL. NEW 12"X12"X12" DEEP PAD FOOTING W/#4 REBAR @6" O.C. MAX. EA WAY AT BOTTOM (N) 3" CONC. 3,000 PSI @ 28 DAYS W/ #3 @ 16" O.C. E.A. WAY OVER 10MIL VISQUEEN OVER EX. GARAGE SLAB DRILLED INTO (E) FOUNDATION AND FILLED WITH SIMPSON'S "SET-XP" EPOXY. 1 2 3 ANCHOR BOLT SCHEDULES: (N) FOOTING: 5/8 X 12" LONG BOLTS @ 48" (U.N.O.) NOTES: -IF MISSING ANCHOR BOLTS THEN DRILL 3/4" X 6" DEEP W/5/8: (RFB#5X10) @32" O.C. WITH SET- XP EPOXY (SPECIAL INSPECTION IS REQUIRED) -SCARIFY TOP 12" OR RE-COMPACT 4" PRIOR TO TRENCHING FOR THE UTILITY AND/OR FOUNDATION. 90% COMPACTION REPORT IS REQUIRED AT THE TIME OF FOUNDATION INSPECTION. PRE-SATURATION SUBGRADE TO 110% OF OPTIMUM MOISTURE CONTENT IS REQUIRED, CODE REQUIREMENT: • • • • • • • THIS PROJECT SHALL COMPLY WITH THE: 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC) 2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS (CEES) 2022 CALIFORNIA BUILDING CODE (CBC) FOUNDATION NOTES: 1. A. B. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. FOUNDATION HAS BEEN DESIGNED ASSUMING MIN. ALLOWABLE SOIL BEARING PRESSURE. (SEC. 1802.6) SHALL BE AS FOLLOWS: CONTINUOUS FOOTING : 1500 SF ISOLATED FOOTING: 1500 SF CONCRETE SHALL HAVE A MIN. COMPRESSIVE STRENGTH (fC) OF 3,000 psi WATER ALL FOOTING SHALL BE POURED ON OR BELOW FIRM UNDISTURBED NATURAL SOIL OR APPROVED COMPACTED FILL AND ADJACENT FINISH GRADE U.N.O. ALL FOOTING SHALL BE CENTERED ON PILATER AND OR WALL AND COLUMN U,N.O. ALL EXISTING FILL SOIL AND DISTRUBED NATURAL SOILS ARE TO BE EXCAVATED AND REPLACED WITH PROPERLY COMPACTED FILL. ALL FILLING, BACKFILLING, RECONNECTION, ETC. IS TO BE ACCOMPLISHED ONLY UNDER THE SUPERVISION OF A SOIL ENGINEER, COMPACTED FILL SHALL BE 95% DENSITY PROVIDE MIN. 5/8" X 12" ANCHOR BOLTS WITH 3"X3"1/4" WASHERS, EMBEDDED 7" MIN. INTO CONCRETE OR MASONRY AND SPACE MAX. 48" O.C. PROVIDE MIN. 2 BOLTS PER PLATE AND NOT MORE THAN 12" OR LESS THAN 4" OR PLATE END AND CORNER. (CHAPTER 4 CRC) FASTENERS FOR PRESERVATIVE-TREATED SHALL BE HOT DIPPED ZINC-COATED GLAVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER IN ACCORDANCE WITH ASTM A 153(R317.3) FOUNDATION SILL PLATE SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. FIELD-CUT ENDS, NTOCHES AND DRILLED HOLES OR PRESERVATIVE TREATED WOOD SHALL BE FIELD-REATED PER AWPA M4.(R317.1.1).\ ALL REINFORCING STEEL SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C-94 ALL EXISTING UTILITIES THAT INTERFERE WITH THE STRUCTURAL FOUNDATIONS SHALL BE REMOVED AND RELOCATED THE CONTRACTOR WILL BE SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING, AND PROTECTION OF ANY ACCORDANCE WITH ALL NATIONAL STATED AND LOCAL SAFETY ORDINANCE READY MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C-94 ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS, AND OTHER INSERTS SHALL BE SECURED IN POSITION AND INSPECTED BY THE LOCAL BUILDING OFFICIAL PRIOR TO THE PLACING OF ANY CONCRETE MINIMUM SLAB REINFORCEMENT AND PAD REQUIREMENTS SHALL CONFORM TO THE SOILS ENGINEER'S RECOPMMENDATIONS UNLIES NOTED OTHERWISE PROVIDE A MIN. 26-GAGE WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MINIMUM O F6" ABOVE EARTH OR 4" ABOVE PACED AREA. (R703.6.2.1) WOD SILL PLATE SHALL BE MINIMUM 8" ABOVE ADJACENT GRADE (R317.1) STRUCTURAL DESIGN DATA: VERTICAL LOADS: DEAD(DL) LIVE(LL) ROOF LOAD:7 PSF 20 PSF CEILING LOAD:6 PSF 10 PSF EXT. WALL LOAD:17 PSF INT. WALL LOAD:7 PSF WIND DESIGN DATA: BASIC WIND SPEED:110MPH WIND EXPOSURE:B EARTHQUAKE DESIGN DATA: IMPORTANCE FACTORE:1=1.0 MAPPED Ss = 1.278 AND Si = 0.457, SdS = 1.022 SITE CLASS: D - DEFAULT SEISMIC DESIGN CATEGORY: D BASIC SEISMIC-FORCE-RESISTING SYSTEM = BWS RESPONSE MODIFICATION FACTOR, R = 6.5 SEISMIC RESPONSE COEFFICIENT, Cs = 0.157 ANALYSIS PROCEDURE USED:EQUIVALENT SOIL DATA: ASSUME ALLOWABLE SOIL BEARING 1,500 PSI 4 1927 & 1929 S Hickory St2/12/2025 2X8 CJ @16" OC 2X8 CJ @16" OC 2X8 CJ @16" OC 2X8 CJ @16" OC 2X8 CJ @16" OC 2X8 CJ @16" OC 2X8 RR @16" OC 2X 6 C J & R R 2X8 RR @16" OC2X8 RR @16" OC 2X8 RR @16" OC2X8 RR @16" OC 3 SD1 6 SD16 SD1 3 SD1 4 SD1 12 SD1 2 2 2 2 2 2 2X 1 0 R I D G E 6x 1 0 B E A M 6x 1 0 B E A M 4X6 HEADER 4X 6 H E A D E R 4X 6 H E A D E R 4X 6 H E A D E R 4X 6 H E A D E R 4X 6 H E A D E R 4X 6 H E A D E R 4X6 HEADER 4X6 HEADER4X10 HEADER 4X 8 H E A D E R 4X 6 H E A D E R 4X 6 H E A D E R 4X6 HEADER 4X6 HEADER 4X 6 H E A D E R 4X 6 H E A D E R 4X6 HEADER 4X6 HEADER 4X4 POST 4X4 POST 8 SD1 8 SD1 2X8 RR @16" OC2X8 RR @16" OC 2X8 CJ @16" OC2X8 CJ @16" OC 2X8 RR @16" OC2X8 RR @16" OC 2X10 RIDGE 4 SD1 4 SD1 9,11 SD1 8'-0"4'-0" 8' - 0 " 4' - 0 " 8'-0" 12 ' - 0 " 10 SD1 2 7 SD1 7 SD1 4' - 0 " 4' - 0 " M I N 4' - 0 " M I N SIMP. CS20 STRAP W/ 10d NAILING OVER 3x4 FLAT BLKG. AT WALL, INSNTALL ON TOP OF 2x BLKG SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 S-2 FRAMING PLAN (ADU) 04/03/24 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U SCALE: 1/4" = 1'-0"1 PROPOSED FRAMING PLAN RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N 1927 & 1929 S Hickory St2/12/2025 8" M I N 24 " M I N . 4 3 5 D 6 2 1 MIN. 6" DOWEL INTO FOOTING 1 2 3 4 5 6 (2) #5 TOP AND BOTTOM MIN. 5" THK. CONC. SLAB W/ #4 REBAR @16 O.C. OVER 10MIL. VISQUEEN OVER 4" BASE OF 1/2 OR LARGER CLEAN AGGREGATE OVER COMPACTED SOIL 5/8" DIA.. A.B @32" OC (U.N.O) EMBED MIN. 7" INTO SLAB W/ 3x3x0.229" PLATE WASHER W/ 2x P.T. SILL U.N.O SHEAR WALL WHERE OCCURS WEEP SCREED 2x STUDS @16" O.C #3 TIE @48" O.C. W/ STANDARD HOOK @EA. END FOR 2 POURS SLAB 2"CONCRETE/PAVE 4" SOIL FIN. GRADE 3" M I N . 24" @ 18" O.C.6" 12" U.N.O. 24 " M I N . 4 3 5 2 1#3 TIE @48" O.C W/ STANDARD HOOK @EA. END FOR 2 POURS SLAB 1 2 3 4 5 (2) #5 TOP AND BOTTOM MIN. 5" THK. CONC. SLAB W/ #4 REBAR @16 O.C. OVER 10MIL. VISQUEEN OVER 4" BASE OF 1/2 OR LARGER CLEAN AGGREGATE OVER COMPACTED SOIL 5/8" DIA.. A.B @32" OC (U.N.O) EMBED MIN. 7" INTO SLAB SHEAR WALL WHERE OCCURS 2x STUDS @ 16" O.C. 3" M I N . 12" U.N.O. DOUBLE TOP PLATED SIMSPON EPCZ POST CAP SIMPSON PER PLAN HEADER OR BEAM PER PLANS POST/KP PER PLANS KING POST PER PLAN HEADER PER PLAN SIMP. A35 BEAM PER PLAN BEAM PER PLANS SIMPSON A35 DOUBLE TOP PLATE SIMP. A35 SLOPE CUT WHERE OCCURS 1/2" OSB ROOF SHEATHING 2x ROOF RAFTER STUD WALL TOP PLATE 2x FASCIA SHIP LAP 2x BLOCKING E.N. 8-16d NAILS C.J TO R.R CEILING JOIST PER PLAN A35 @16" OC U.N.O. CEILING JOIST PARALLEL TO ROOF JOIST SHEAR WALL WHERE OCCURS EQ EQ 45° M I N . 2x4 KICKER @4' MAX.OCSIMPSON A35 (2) SIMPSON A35 E.A R.R SIMPSON LSTA24 STRAP @32" O.C C.J PER PLANS BEARING WALL PER PLANS OVERLAP 12" MIN. W/(10) 16D NAIL WOOD BEAM PER PLAN WOOD POST PER PLAN SIMPSON "ECCQ" CAP B A WOOD BEAM PER PLAN WOOD POST PER PLAN SIMPSON "ECCQ" CAP EQ EQ 2x4 KICKER @ 4' MAX.OC SIMPSON A35 PROVIDE (2) A35 @ E.A RAFTER TO RIDGE SIMPSON LSTA24 STRAP @32" O.C 45° M I N . FLUSH BEAM OR WALL PER PLAN C.J PER PLANS CONTINUOUS TOP PLATE HEADER PER PLAN SIMP. ST 18 ONE SIDE POST PER PLAN EQ EQ PROVIDE (2) A35 @ EA. RAFTER TO RIDGE SIMPSON LSTA24 @32" O.C 2x4 COLLAR TIE @32"O.C. 3-10d NAILS 1' - 1 0 " M A X . 1. 2x4 STUDS @ 16"O.C. 2. 2X P.T.D.F. PLATE WITH 0.18"DIA. x 3" SHOT PINS @32" O.C. WITH 14GA GAGE WASHERS & FIRST 2 PINS PLACED 6" & 10" FROM PLATE ENDS ICC# ESR-1799 (RAMSET) LARR #22668 3. CONCRETE SLAB 4. 1/2" DRYWALL 4 123 1. NOTCH IN PLATE 2. 1 3/4" MAX. IF BORED HOLE EXCEED 1 3/4" IN 2x4 TOP PLATE OR 2 3/4" IN 2x6 TOP PATE, STRAP E/S OF PLATE W/ITEM #3 BELOW 3. SIMPSON CS 1 6x4" LONG METAL STRAP, TYPICAL @ EACH PLATE CUT W/(6) 16d's EACH SIDE. 4. PIPE WHERE OCCURS 5. TOP PLATES-SILL PLATES 6. ANCHOR BOLTS PER PLANS 7. LOCATE ANCHOR BOLT 5" MIN. 9" MAX. AWAY FROM NOTCH OR END OF PLATE NOTE: IF NOTCH OR HOLE EXCEEDS 50% OF TOP PLATE WIDTH, USE SIMPSON ST6224, STAGGERED @ E/S OF PLATES, USE SIMPSON NS AS NEEDED. 4345 1 2 5 37 DEPT H 1/2 DEPTH 3" MAX. 1. NOTCH DEPTH & BORED HOLD SEE TABLE BELOW. 2. STUD 3. STILL PLATE 4. HOLE EDGE DISTANCE 5/8" MIN. NOTE: BORED HOLES NOT PERMITTED IN MORE THAN TWO CONSECUTIVE DOUBLE STUDS BORED HOLES STUD SIZE EXTERIOR & BEARING WALLS NON- BEARING WALLS 2x4 2x6 2-2x4 2-2x6 % 1 7/16" 2 1/8" 40% 2 1/8" 2 1/8" 60% 2 3/16" 3 5/16" 3 5/16" 3 5/16" STUD SIZE EXTERIOR & BEARING WALLS NON- BEARING WALLS NOTCH DEPTH 2x4 2x6 % 7/8"1 7/16" 1 3/8"2 3/16" 25%40% 1 4 2 3 4 1 d MIN. 12" U.N.O. 3" M I N . 24 " M I N . 2% SLOPE MIN. 1 2 3 4 (2) #5 TOP AND BOTTOM MIN. 5" THK. CONC. SLAB W/ #4 REBAR @16 O.C. OVER 10MIL. VISQUEEN OVER 4" BASE OF 1/2 OR LARGER CLEAN AGGREGATE OVER COMPACTED SOIL 1/2" FIBER BOARD EXPANSION JOINT MIN. 4" THK. CONC. SLAB W/ #3 REBARD @18" O.C O/ COMPACTED SOIL 234 1 5 5 #4 @ 18" O.C. 24" 6" ANCHOR BOLTS (AB) SHALL BE 5/8" WITH 3"X3'X0.229" THICK PLATE WASHERS. SPACING OF ANCHOR BOLTS SHALL NOT EXCEED 6'-0" O.C. EACH SECTION OF PLATE SHALL HAVE A MINIMUM OF TWO AB. ANCHOR BOLTS SHALL BE EMBEDDED A MINIMUM OF 7" INTO FOOTING. HOLES SHALL BE 1/32" TO 1/6" LARGER THAN AB. LARGER HOLES SHALL BE REPAIRED WITH EPOXY. PLATES SHALL BE PRESSURE TREATED DOUGLAS FIR NOT HEM-FIR. 12 " M A X . 5" M I N . 12" MAX 5" MIN. 12 " M A X 5" M I N . 12" MAX 5"MIN. 12" MAX 5" MIN 2" M A X AB SPACING 6' MAX OR PER SHEAR WALL SCHEDULE (TYP) PANEL PER PLAN (TYP.) AT CORNER AT INTERSECTION AT SPLICE TRUSS WHERE OCCURS PER PLAN SIMPSON "DTC" @48" O.C. MAX. 2X BLK'G. @48" O.C. W/ (3) 16d'S @ EA.END JOIST OR TRUSS BOTT. CHORD 1X OVER 2X PLATE3/ 4 " T Y P . NON-BRG. WALL 0' - 8 " 1' - 0 " 1' - 0" CBSQ POST BASE, INSTALL PER MANUFACTURES SPECIFICATIONS CONCRETE SLAB WHERE OCCURS UNDISTURBED NATURAL GRADE POST PER PLAN 12" SQUARE CONCRETE PIER WOOD POST PER PLAN CONCRETE SLAB PER PLAN VAPOR BARRIER IN DIRECT CONTACT W/ CONC. SLAB PER ARCH. PLANS 4" THICK BASE OF 1/2" OR LARGER CLEAN AGGREGATEMI N . 1' - 6 " CL R . 0' - 3 " REINFORCING PER PLAN CONT. FT'G BEYOND COLUMN BASE SCHEDULE CB44 W/2-1/2" DIA.. M.B. FOR 4x4 POST CB46 W/2-5/8" DIA.. M.B. FOR 4x6 POST CB66 W2-5/8" DIA.. M.B. FOR 6x6 POST CB88 W/2-3/4" DIA.. M.B. FOR 8x8 POST SEE PLAN 1X6 SHIP-LAPS 2X LOOK-OUT @24" O.C.BN 2X BLKG 1/2" OSB PLWD ROOF SHEAT G MIN. CLASS B A35 PER SCHED. BN2X FASCIA 2X CRIPPLES @ 16" OC 2X BLKG EN. 4X HDR WHERE OCCURS 45° 2X4 BRACE @ 48" O.C. W/ 3-16D TOE NAILS EA. END. R-30 TYP.A35 PER SCHED. 2X DBL TOP PLATES R-13 TYP. 2X STUDS @ 16" O.C. SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 SD1 STRUCTURAL DETAILS 04/03/24 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U EXTERIOR POST FOOTING WOOD POST TO WOOD BEAM CONNECTION DETAIL WOOD POST BASE TO PAD DETAIL 0301NEW EXTERIOR FOOTING 02NEW INTERIOR FOOTING 04FLUSH BEAM TO POST CONNECTION 05KING POST TO HEADER 06RAFTER AT EXTERIOR WALL 07RIDGE SUPPORTING 08 09BEAM-CEILING JOIST-RIDGE CONNECTION 10HEADER TO POST 11FLUSH RIDGE 12NON-BEARING INT. WALL TYP., N.T.S.13PIPING THRU PLATE FRAMING, N.T.S.14FLUSH BEAM TO POST CONNECTION 15PORCH TO HOUSE FOOTING 16TYPICAL PLATE ANCHOR BOLTS 18INTERIOR WALL 19 20 RAKE DETAIL RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N 1927 & 1929 S Hickory St2/12/2025 SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 CG.1 CAL. GREEN REQUIREMENTS 04/03/24 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N 1927 & 1929 S Hickory St2/12/2025 SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 CG.2 CAL GREEN REQUIREMENTS 04/03/24 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N 1927 & 1929 S Hickory St2/12/2025 SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 T24 T24 04/10/2024 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N 1927 & 1929 S Hickory St2/12/2025 S. HICKORY ST.S. HICKORY ST. 47.00'47.00'PROPERTY LINEPROPERTY LINE 10 8 . 0 0 ' 1 0 8 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 10 8 . 0 0 ' 1 0 8 . 0 0 ' 10 8 . 0 0 ' 1 0 8 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 10 8 . 0 0 ' 1 0 8 . 0 0 ' 1929 S HICKORY ST., SANTA ANA, CA (E) SINGLE-FAMILY DWELLING (E ) C O N C R E T E D R I V E W A Y WM (E) ELECTRIC PANEL TO BE CONVERTED TO (N) SUBPANEL FOR PRIMARY HOUSE (E) WATER METER (E) GRASS (E) GRASS G (E) UNDERGROUND GAS METER E D B C B 1927 S HICKORY ST (N) ACCESSORY DWELLING UNIT 715 SF (N) 200 AMP DUAL METER PANEL (N) GARAGE 256 SF 46.00'46.00' 47.00'47.00'PROPERTY LINEPROPERTY LINE 46.00'46.00' (E) MULCH SIDEWALK 16' - 11" 20' - 0" 5% 5% 4' - 0" 15' - 0" 31 ' - 6 " UNPERMITTED WORK 23' - 0" 5' - 0" LA N D S C A P E 12' - 0" 20 ' - 0 " UNPERMITTED FENCE, REPLACE & BUILD NEW FENCE 7 A2 SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 A6 EROSION & SEDIMENT CONTROL PLAN 04/10/2024 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. EROSION CONTROL IS REQUIRED FOR GRADING OPERATIONS DURING THE RAINY SEASON FROMOCTOBER 15TH TO APRIL 15TH. APPROVED PLANS ARE REQUIRED FOR ALL ROUGH GRADING. IN CASE OF EMERGENCY, CALL: ORCHID L & HAN NGUYENT AT (714) 417 32023. THE DESIGN CIVIL ENGINEER WILL SUPERVISE EROSOIN CONTROL WORK AND ENSURE THAT WORK IS IN ACCORDANCE WITH THE APPROVED PLANS (IF REQUIRED). EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON.NECESSARY MATERIALS SHALL BE AVAILABLE ON SITE ANDSTOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARYDEVICES WHEN RAIN IS IMMINENT. DEVICES SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE CITY ENGINEER. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE 5.DAYS RAIN PROBABILITY FORECAST EXCEEDS 40%. AFTER A RAINSTORM, ALL SILT AND DEBRIS SHALL BE REMOVED FROM CHECK GRADED AREAS AROUND THE TRACK PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATER CREATES A HAZARDOUSCONDITION. DESILTING BASINS ARE TO BE CONSTRUCTED AS GRADING OF INDIVIDUAL GRADING AREAS ARECOMPLETE PER ROUGH GRADING PLANS. THE CITY ENGINEER RESERVES THE RIGHT TO MAKE CHANGES OR MODIFICATIONS TO THIS PLANAS DEEMED NECESSARY. INFORMATION IN THIS PLAN IS FOR EROSION CONTROL ONLY.ALL OTHER INFORMATION ISSUBJECT TO CHANGE. TEMPORARY EROSION PROTECTION IS REQUIRED FOR MANUFACTURED SLOPES PRIOR TOPERMANENT PLANTING. AREAS SHALL BE MAINTAINED IN SUCH A STATE THAT FIRE ACCESS SHALL SEE MAINTAINED ATALL TIMES (INCLUDING ACCESS TO NEIGHBORING PROPERTIES). NO OBSTRUCTION OR DISTURBANCE OF NATURAL DRAINAGE COURSES OR EXISTING STORMDRAIN INLETS SHALL OCCUR DURING THE RAINY SEASONS, UNLESS ADEQUATETEMPORARY/PERMANENT DRAINAGE FACILITIES HAVE BEEN APPROVED AND INSTALLED TOCARRY SURFACE WATER TO THE NEAREST PRACTICAL STREET, STORM DRAIN OR NATURALWATER COURSE. THE CONTRACTOR SHALL CONDUCT HIS OPERATIONS IN SUCH A MANNER THAT STORM RUNOFF WILL BECONTAINED WITHIN THE PROJECT OR CHANNELS INTO THE STORM DRAIN SYSTEM WHICH SERVES THE RUNOFF AREA.STORM RUNOFF FROM ONE ARE SHALL NOT BE ALLOWED TO DIVERT TO ANOTHER RUNOFF AREA. CONFORMANCE WITH THE REQUIREMENT OF THESE PLANS SHALL IN NO WAY RELIEVE THE CONTRACTOR FROMHIS RESPONSIBILITIES TO THIS SITE AND ADJACENT PROPERTIES. TEMPORARY EROSION CONTROL SHALL CONSIST OF,BUT NO TO BE LIMITED TO, CONSTRUCTING SUCH FACILITIES AND TAKING SUCH MEASURES AS ARE NECESSARY TOPREVENT, CONTROL AND ABATE WATER, MUD AND EROSION DAMAGE TO PUBLIC AND PRIVATE PROPERTY AS ARESULT OF THE CONSTRUCTION OF THIS PROJECT. SLOPES CONSTRUCTED PRIOR TO OCTOBER 1 SHALL BE TREATED FOR EROSION CONTROL PRIOR TO OCTOBER15. SLOPES CONSTRUCTED AFTER OCTOBER 1 SHALL BE TREATED FOR EROSION CONTROL AS THE CONSTRUCTION OFSLOPE PROGRESS IN INCREMENT OF 25 FEET OR LESS MEASURES VERTICALLY. FILL AREAS WHILE BROUGHT UP TO GRADE AND DURING PERIODS OF COMPLETION PRIOR TO FINAL GRADE,SHALL BE PROTECTED BY VARIOUS MEASURES TO ELIMINATE EROSION AND THE SILTATION OF DOWNSTREAMFACILITIES AND ADJACENT AREAS. THESE MEASURES MAY INCLUDE, BUT SHALL NOT BE LIMITED TO: TEMPORARYDOWNDRAINS, EITHER IN THE FORM OF PIPES OR PAVED DITCHES WITH PROTECTED OUTFALL AREAS; GRADED BERMSAROUND AREAS TO ELIMINATE EROSION OF FILL SLOPES BY SURFACE RUNOFF, CONFINED PONDING AREAS TO DESILTRUNOFF; TEMPORARY CHECK DAMS IN TOE OF SLOPE DITCHES TO DESILT RUNOFF; PROTECTION SUCH AS SANDBAGS AROUND INLETS WHICH HAVE NOT BEEN BROUGHT UP TO GRADE, AND EARTH BERMS AND APPROPRIATEGRADING TO DIRECT DRAINAGE AWAY FROM THE EDGE OF THE SLOPES SHALL BE CONSTRUCTED AND MAINTAINED ONTHOSE FILL AREAS WHERE EARTH-WORK OPERATIONS ARE NOT IN PROGRESS. TOP OF CUT BROW DITCHES, WHERE REQUIRED ON THE PLANS, SHALL BE CONSTRUCTED PRIOR TO EXCEEDING12 FEET OF CUT MEASURED VERTICALLY. CLEARING AND GRUBBING SHOULD BE LIMITED TO AREAS THAT WILL RECEIVE IMMEDIATE GRADING. EROSION CONTROL MEASURES WILL BE REQUIRED TO PROTECT AREAS THAT HAVE BEEN CLEARED AND GRUBBED PRIOR TOGRADING OPERATION, AND THAT ARE SUBJECT TO RUNOFF DURING THE PERIOD FROM THE BEGINNING OF THE RAINYSEASON. THESE MEASURES MAY INCLUDE BUT SHALL NOT BE LIMITED TO: GRADED DITCHES; BRUSH BARRIERSAND SILT FENCES. CARE SHALL BE EXERCISED TO PRESERVE VEGETATION BEYOND THE LIMITS OF GRADING. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM RESPONSIBILITY FOR THE CORRECTIONOF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. UPON REQUEST, THE REQUIRED PLAN REVISIONSSHALL BE PROMPTLY TO THE CITY ENGINEER FOR APPROVAL. EROSION CONTROL GENERAL NOTES: SCALE: 1/8" = 1'-0"1 EROSION & SEDIMENT CONTROL PLAN RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N 1927 & 1929 S Hickory St2/12/2025 S. HICKORY ST.S. HICKORY ST. 47.00'47.00'PROPERTY LINEPROPERTY LINE 10 8 . 0 0 ' 1 0 8 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 10 8 . 0 0 ' 1 0 8 . 0 0 ' 10 8 . 0 0 ' 1 0 8 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 10 8 . 0 0 ' 1 0 8 . 0 0 ' 1929 S HICKORY ST., SANTA ANA, CA (E) SINGLE-FAMILY DWELLING (E ) C O N C R E T E D R I V E W A Y WM (E) WATER METER (E) GRASS (E) GRASS G (E) UNDERGROUND GAS METER 69.6' 70.0' 70.4' 70.5' 70.7' 70.5' (E) ELECTRIC PANEL (E) SHED TO BE REMOVED 46.00'46.00' 47.00'47.00'PROPERTY LINEPROPERTY LINE 46.00'46.00' (E) MULCH SIDEWALK 7' - 6 " 4' - 0" 15' - 0" 31 ' - 6 " UNPERMITTED WORK LA N D S C A P E 20 ' - 0 " UNPERMITTED FENCE, REPLACE & BUILD NEW FENCE 7 A2 S. HICKORY ST.S. HICKORY ST. 47.00'47.00'PROPERTY LINEPROPERTY LINE 10 8 . 0 0 ' 1 0 8 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 10 8 . 0 0 ' 1 0 8 . 0 0 ' 10 8 . 0 0 ' 1 0 8 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 10 8 . 0 0 ' 1 0 8 . 0 0 ' 1929 S HICKORY ST., SANTA ANA, CA (E) SINGLE-FAMILY DWELLING (E ) C O N C R E T E D R I V E W A Y WM (E) ELECTRIC PANEL TO BE CONVERTED TO (N) SUBPANEL FOR PRIMARY HOUSE (E) WATER METER (E) GRASS (E) GRASS G (E) UNDERGROUND GAS METER 2% 5% 1927 S HICKORY ST (N) ACCESSORY DWELLING UNIT 715 SF 69.6' 70.0' 70.4' 70.5' 70.7' 70.5' (N) 200 AMP DUAL METER PANEL (N) GARAGE 256 SF 46.00'46.00' 47.00'47.00'PROPERTY LINEPROPERTY LINE 46.00'46.00' (E) MULCH SIDEWALK 7' - 6 " 2% 2% 5% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 16' - 11" 20' - 0" 5 A5 5% 5% 4' - 0" 15' - 0" 31 ' - 6 " UNPERMITTED WORK 23' - 0" 5' - 0" LA N D S C A P E 12' - 0" R 1 4 ' - 4 1 3 / 1 6 " R 1 8 ' - 0 " R 36' - 0 " CAR TURNING PATH 20 ' - 0 " UNPERMITTED FENCE, REPLACE & BUILD NEW FENCE 7 A2 SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 A7 EXISTING & PROPOSED CONTOUR MAP 04/03/24 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U SCALE: 1/8" = 1'-0"1 EXISTING CONTOUR MAP SCALE: 1/8" = 1'-0"2 PROPOSED CONTOUR MAP RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N 1927 & 1929 S Hickory St2/12/2025 GFI WP WP 220V EGD 3 4 D 220 vs FS CT R CLG SD T H J W TV AC RETURN AIR VENT 200A SERVICE PANEL WITH 225 AMP MIN. BUSBAR RATING 60AMP PANEL FOR FUTURE ESS USE IAQ FAN AC CONDENSER WATER HEATER M M M M M ATTIC ACCESS 3' - 0 " 6' - 1 1 " 3' - 0 " M ELECTRICAL SYMBOLS DUPLEX RECEPTACLE MOUNTED IN CEILING FOR GARAGE DOOR OPENER FLOOR MTD. RECEPTACLE POL BRASS RECEPTACLE 1/2 SWITCHED SINGLE POLE SWITCH 3 WAY SWITCH 4 WAY SWITCH DUPLEX RECEPTACLE ON ALL BRANCH CIRCUITS THAT SUPPLY 125- VOLT, SINGLE-PHASE, 15 & 20AMP RECEPTACLE OUTLETS IN DWELLING UNIT SHALL BE PROTECTED BY A COMBINATION TYPE (AFCI) ARC- FAULT CIRCUIT INTERRUPTER(S) PER 2010 CEC 210.12. FUSED SWITCH WATERPROOF RECEPTACLE DUPLEX RECEPTACLE ON GROUND-FAULT INTERRUPTED CIRCUIT DUPLEX RECEPTACLE LOCATED UNDER COUNTER 220V RECEPTACLE (VERIFY AMPERAGE REQUIREMENTS) RECESSED HIGH EFFICACY LIGHT FIXTURE WEATHER PROOF VAPOR PROOF, RECESSED, HIGH EFFICACY LIGH FIXTURE HANGING HIGH EFFICACY LIGHT FIXTURE - CHANDELIER I00 LB SUPPORT MIN. WALL MOUNTED HIGH EFFICACY LIGHT FIXTURE SURFACE MOUNTED HIGH EFFICACY LIGHT FIXTURE SOLAR POWERED, PHOTOCONTROL STEP MOUNTED LIGHT FIXTURE VENT / LIGHT COMBO, BY VENT AXIA CEILING EXHAUST FAN / FLUORESCENT LIGHT WHISPER FIT 4" DUCT. PANASONIC OR EQUAL STANDARD SERVICE TELEPHONE OUTLET CAT 5 COMBINED: COMPUTER DATA LINE AND TELEVISION CABLE OUTLET SMOKE DETECTOR SHALL BE PROTECTED BY AND ARC-FAULT CIRCUIT INTERRUPTER PER 2019 CEC 210.10. SMOKE DETECTORS SHALL HAVE A 10 YEAR BATTERY AND SHALL BE REPLACED 10 YEARS FROM THE DATE MARKED ON THE UNIT PER 2019 CBC 907.2.11.2, AND 2019 CRC R314 - R315. GAS LINE HOSE BIB JUNCTION BOX HEATING OUTLET IAQ FAN HUMIDISTAT CONTROL VACANCY LIGHT SWITCH 220 VOLT FUSED SWITCH SINGLE POLE SWITCH WITH DIMMER THERMOSTAT CARBON MONOXIDE ELECTRIC VEHICLE CHARGER VACANCY SENSOR UNDER-CABINET LED STRIP LIGHT DUPLEX RECEPTACLE LOCATED ABOVE CEILING CEILING EXHAUST FAN PANASONIC WHISPER FIT FAN 4" DUCT WITH HUMIDITY CONTROL HB GAS VS CM EVC C5 S VP DUPLEX RECEPTACLE FOR TELEVISION ELECTRIC PANEL INDOOR AIR HANDLER, MINI-SPLITAC F H ELECTRICAL ABBREVIATIONS A AMP AT AUTOMATIC TIME SWITCH CONTROL AST ASTRONOMICAL TIME CLOCK C/CW COLD WATER D DIMMER / DIMMABLE DED DEDICATED OUTLET / CIRCUIT EMCS EMERGENCY MANAGEMENT CONTROL SYSTEM (CENC 105 (K) 3,A,III,C) EV ELECTRICAL VEHICLE EVSE ELECTRIC VEHICLE SUPPLY EQUIPMENT FAU FORCED AIR UNIT FG NATURAL GAS FL FLOURESCENT FSR FIRE SPRINKLER RISER GFI GROUND FAULT CIRCUIT INTERRUPTER HB HOSE BIB HC HUMIDISTAT CONTROL HE HIGH EFFICACY H/HW HOT WATER JA8 COMPLAINT W/ APPENDIZ JA8 L, LED LED LIGHT FIXTURE LVL EVSE LEVEL MR MOISTURE RESISTANT (INDOOR) MS MOTION SENSOR PB PUSH BUTTON PC PHOTOCELL SOV SHUT OFF VALVE VS VACANCY SENSOR V VOLT WP WEATHER PROOF (RATED FOR EXTERIOR) ELECTRICAL NOTES CODE REFERENCES BASED ON 2022 CALIFORNIA ELECTRICAL CODE 1 MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS ARE SHOWN FOR INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION AND PLACEMENT. 2 3 4 5 NUMBER OF CEILING JUNCTION BOXES NOT CONTAINING INSTALLED LIGHTING OR OTHER DEVICES SHALL NOT EXCEED NUMBER OF BEDROOMS. ELECTRICAL BOXES MUST BE SERVED BY A DIMMER, VACANCY SENSOR OR FAN SPEED CONTROL. CENC 150 (k) 1B 6 ELECTRONIC BALLASTS ARE REQUIRED FOR ALL LAMPS RATED 13 WATTS OR GREATER. 7 ALL INSTALLED LUMINAIRES SHALL BE HIGH-EFFICACY IN ACCORDANCE WITH CENC TABLE 150.0-A. (CENC 150 (k) 1A). 8 RECESSED LUMINAIRIES IN CEILINGS SHALL BE APPROVED FOR ZERO-CLEARANCE CONTACT (IC) & CERTIFIED AIRTIGHT, SHALL NOT CONTAIN SCREW BASED SOCKETS, AND SHALL BE SEALED WITH GASKET OR CAULK BETWEEN HOUSING AND CEILING, AND SHALL BE JA8 COMPLIANT, PER CENC 150.0 (k) 1C 9 DIMMERS OR VACANCY SENSORS SHALL CONTROL ALL LUMINAIRES REQUIRED TO HAVE JA8 COMPLIANT LIGHT SOURCES - CENC 150 (k) 2K). a. LIGHTING IN CLOSETS LESS THAN 70 SQ.FT. ARE NOT REQUIRED TO BE JA8 COMPLIANT - CENC 150(k) 2, k, EX. 1 b.RECESSED LIGHT FIXTURES IN HALLWAYS ARE NOT REQUIRED TO BE JA8 COMPLIANT - CENC 150 (k) 2K, EX. 2 10 AT LEAST ONE LUMINAIRE IN BATHROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS SHALL BE HIGH EFFICACY AND CONTROLLED BY VACANCY SENSORS (CENC 150 (k) 2J). 11 UNDERCABINET LIGHTING SHALL BE SWITCHED SEPARATELY FROM OTHER LIGHTING SYSTEMS. (CENC 150 (k) 2L). 12 EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEM. (OR SEE EXCEPTION - CENC 150 (k) 2B.) 13 14 ALL KITCHEN, BATHROOM, LAUNDRY ROOM, GARAGE AND EXTERIOR RECEPTACLES SHALL BE GFCI PER CEC 210.8(A) 15 ALL 125-VOLT, 15 AND 20 AMPERE DWELLING UNIT RECEPTACLES SHALL BE LISTED TAMPER- RESISTANT PER CEC 406.12 16 PROVIDE A MINIMUM OF 2-20 AMP CIRCUITS TO KITCHEN COUNTERTOPS FOR SMALL APPLIANCES PER CEC 210.11 (C) (1) 17 PROVIDE A MINIMUM OF 1-20 AMP LAUNDRY BRANCH CIRCUIT PER CEC 210.11 (C) (2) 18 A DEDICATED 120V, 20 AMP CIRCUIT SHALL SERVE THE REQUIRED BATHROOM OUTLETS. THIS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS, FANS, ETC. CEC 210.11 (C) (3) 19 ALL BRANCH CIRCUITS SUPPLYING 12O-VOLT SINGLE-PHASE 15 & 20-AMPERE RECEPTACLE OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, REC ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER(S) PER CEC 210.12(A). 20 STRUCTURED WIRING PANELS LOCATED IN CLOTHES CLOSET SHALL NOT CONTAIN OVERCURRENT DEVICES PER CEC 240.24 21 A 120V ELECTRIC RECEPTACLE SHALL BE LOCATED WITHIN 3FT FROM THE WATER HEATER AND BE ACCESSIBLE TO THE WATER HEATER WITHOUT OBSTRUCTIONS. (CENC 150 (n)1A) 22 23 RECEPTACLES THAT ARE REQUIRED AT THE FRONT AND REAR OF THE HOME, AND ON BALCONIES, DECKS & PORCHES, MUST BE WITHIN 6 FEET 6 INCHES OF GRADE (AND WATERPROOF AND GFCI PROTECTED). CEC 210.52 (E) & 210.8(A) EXTERIOR LIGHT FIXTURES & WEATHERPROOF OUTLETS SHALL BE INSTALLED PER CEC 410.10(A) & 406.9, & CENC 150.0 (k) 3 EXTERIOR LIGHTING SHALL BE CONTROLLED BY MANUAL ON & OFF SWITCH THAT DOES NOT OVERRIDE TO ON THE AUTOMATIC ACTIONS OF ITEMS ii OR iii BELOW. SHALL ALSO BE CONTROLLED BY ONE OF THE FOLLOWING: II. PHOTOCELL AND MOTION SENSOR OR III. ONE OF THE FOLLOWING: a. PHOTOCONTROL & AUTOMATIC TIMER b. ASTRONOMICAL TIME CLOCK c.RGY MANAGEMENT CONTROL SYSTEM (EMCS) AS NOTED CENC 150.0 (k) 3A INTERNALLY ILLUMINATED ADDRESS SIGNS SHALL:: a. COMPLY WITH CENC 140.8; or b. SHALL CONSUME NO MORE THAN 5 WATTS OF POWER AS DETERMINED ACCORDING TO CENC 130.0 ( c) 24 SMOKE ALARMS SHALL BE INTERCONNECTED W/ BATTERY BACKUP OR EMERGENCY ELECTRICAL SYSTEM CRC R314.4 25 SMOKE ALARMS SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS: CRC R314.3 & R314.3.3 a. IN EACH SLEEPING ROOM b.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS c.ON EACH ADDITIONAL STORY LOCATION REQUIREMENTS: d.MIN. 3 FT. FROM BATHROOMS WITH TUBS OR SHOWERS. e. MIN. 20 FT. FROM PERMANENTLY INSTALLED COOKING e) APPLIANCES. OR SEE EXCEPTIONS NFPA 29.8.3.4 WHEN UNABLE TO ACHIEVE DISTANCE REQUIRED. f.MIN. 3 FT. FROM TIP OF SUSPENDED CEILING FAN BLADE. g.WITHIN 12 IN. VERTICALLY FROM HIGHEST POINT OF SLOPED OR COFFERED CEILINGS. h.3 FT. HORIZONTAL PATH FROM THE SUPPLY REGISTERS OF A FORCED AIR HEATING OR COOLING SYSTEM AND SHALL BE INSTALLED OUTSIDE OF THE DIRECT AIRFLOW FROM THOSE REGISTERS. 26 CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: CRC R315.3 a.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS b.ON EVERY OCCUPIABLE LEVEL, INCLUDING BASEMENTS c IN BEDROOMS CONTAINING A FUEL-BURNING APPLIANCE (I.E. FIREPLACE) ** COMBINATION SMOKE AND CARBON MONOXIDE ALARMS SHALL BE PERMITTED IN LIEU OF SMOKE ALARMS OR CO2 ALARMS CRC R314.5, R314.7.4, & R315.4 31 COMBINATION SMOKE AND CARBON MONOXIDE DETECTORS SHALL BE INTERCONNECTED AND RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING, OR FROM A BATTERY BACKUP WHEN PRIMARY POWER IS INTERRUPTED (CRC R314 AND R315) 32 TWO OR MORE SMALL APPLIANCE BRANCH CIRCUITS ARE REQUIRED FOR THE KITCHEN AND ARE LIMITED TO SUPPLYING WALL AND COUNTER SPACE OUTLETS FOR THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM, OR SIMILAR AREAS. THESE CIRCUITS CANNOT SERVE OUTSIDE PLUGS, RANGE HOOD, DISPOSALS, DISHWASHERS OR MICROWAVES - ONLY THE REQUIRED COUNTERTOP/WALL OUTLETS INCLUDING THE REFRIGERATOR (CEC 210-11(C) & 210-52(B)) FAN/LIGHTS LOCATED WITHIN 3FT HORIZONTALLY AND 8FT VERTICALLY OF THE BATHTUB RIM OR SHOWER STALL THRESHOLD SHALL BE LISTED FOR A DAMP OR WET LOCATION ARE SUBJECT TO SHOWER SPRAY. (PER CEC 410.10 (D) ) COMBINATION SMOKE AND CARBON MONOXIDE ALARMS SHALL BE PERMITTED IN LIEU OF SMOKE ALARMS OR CO2 ALARMS (CRC R314.5, R314.7.4, & R315.4) 27 ATLEAST ONE 120-VOLT, 20-AMPERE BRANCH CIRCUIT SHALL BE INSTALLED TO SUPPLY RECEPTACLE OUTLETS IN ATTACHED GARAGES AND IN DETACHED GARAGES WITH ELECTRIC POWER. THIS CIRCUIT SHALL HAVE NO OTHER OUTLETS. EXCEPTION: CIRCUIT SHALL BE PERMITTED TO SUPPLY READILY ACCESSIBLE OUTDOOR RECEPTACLE OUTLETS (CEC 210.11) MECHANICAL NOTES CODE REFERENCES BASED ON 2022 CALIFORNIA MECHANICAL CODE 1. 2. 3. 4. 5. 6. 7. 8. a. b. 9. 10. 11. 12. 13. 14. 15. 16. 17. ROOMS CONTAINING TUBS, SHOWERS OR SIMILAR BATHING FIXTURES SHALL BE MECHANICALLY VENTILATED IN ACCORDANCE WITH CMC APPDX E 605.2 & CRC R303.3.1 INCLUDING ACCESSIBLE HUMIDISTAT CONTROL (CGBC 4.506.1) ALL EXHAUST DUCTS SHALL HAVE SMOOTH INTERIOR SURFACE AND TERMINATE OUTSIDE THE BUILDING AND SHALL BE EQUIPPED WITH A BACKDRAFT DAMPER. (CMC 504.1) TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS (i.e., CLOTHES DRYER VENTS, BATH AND UTILITY FANS, ETC.) SHALL BE A MINIMUM OF 3 FEET FROM PROPERTY LINES OR ANY OPENINGS INTO THE BUILDING. PER CMC 502.2.1 DRYER VENT OUTLET SHALL BE MIN. 5 FT. FROM AIR CONDITIONING CONDENSER (CENC 150 (h) 3.A) PROVIDE MIN. 4" DIA. SMOOTH METAL DRYER VENT W/ BACKDRAFT DAMPER TO EXTERIOR. VENT RUN SHALL COMPLY WITH MNFR.'S SPECS. AND CMC 504.4.2 & 908. LENGTH OF RUN MAY EXCEED 14'-0" IF PERMITTED BY DRYER MNFR.'S INSTALLATION INSTRUCTIONS AND APPROVED BY THE AUTHORITY HAVING JURISDICTION. WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING OF NOT LESS THAN 100 SQUARE INCHES FOR MAKEUP AIR SHALL BE PROVIDED IN THE DOOR OR BY OTHER APPROVED MEANS PER CMC 504.4.1 WHOLE BUILDING VENTILATION SHALL BE PROVIDED AND CONFIRMED THRU FIELD VERIFICATION & DIAGNOSTIC TESTING, PER CENC 150 (o) CALCULATION: 1 CFM PER 100 SF. FLOOR AREA PLUS NUMBER OF BEDROOMS PLUS ONE, MULTIPLIED BY 7.5 CFM. EXAMPLE: 1500 SF HOME W/ 3 BEDRMS = 15 CFM BLDG + 30 CFM PER OCCUPANT = 45 CFM REQUIRED. HOUSEHOLD COOKING APPLIANCES SHALL HAVE A VERTICAL CLEARANCE ABOVE THE COOKING TOP OF NOT LESS THAN 30INCHES TO COMBUSTIBLE MATERIAL OR METAL CABINETS (CMC 920.3.2) CLOTHES DRYER EXHAUST DUCT SHALL NOT BE CONNECTED TO A VENT CONNECTOR, GAS VENT OR CHIMNEY AND SHALL NOT TERMINATE INTO A CRAWL SPACE, ATTIC OR OTHER CONCEALED SPACE. EXHAUST DUCTS SHALL NOT BE ASSEMBLED WITH SCREWS OR OTHER FASTENING MEANS THAT EXTEND INTO THE DUCT AND THAT ARE CAPABLE OF CATHING LINT, AND THAT REDUCE THE EFFICIENCY OF THE EXHAUST SYSTEM. SCREENS SHALL NOT BE INSTALLED AT THE DUCT TERMINATION. WHERE JOINING OF DUCTS, THE MALE END SHALL BE INSERTED IN THE DIRECTION OF AIRFLOW (CMC 504.4) DOMESTIC CLOTHES DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14FT, INCLUDING TWO 90-DEGREE ELBOWS. A LENGTH OF 2FT SHALL BE DEDUCTED FOR EACH 90-DEGREE ELBOW IN EXCESS OF TWO (CMC 504.4.2.1) CLOTHES WASHER STANDPIPES SHALL BE 2INCH IN DIAMETER. NO TRAP FOR A CLOTHES WASHER STANDPIPE RECEPTOR SHALL BE INSTALLED BELOW THE FLOOR, BUT SHALL BE ROUGHED IN NOT LESS THAN 6INCHES AND NOT MORE THAN 18INCHES ABOVE THE FLOOR. (CPC 804.1) NO STANDPIPE RECEPTOR FOR A CLOTHES WASHER SHALL EXTEND MORE THAN 30INCHES AND NOT LESS THAN 18INCHES ABOVE ITS TRAP. (CPC 804.1) SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : DE L T A C O N S T R U C T I O N C O . 86 7 1 G A R D E N G R O V E BL V D . , G A R D E N G R O V E 71 4 - 9 8 7 - 0 7 8 7 A4 PROPOSED ELECTRICAL PLAN 04/10/2024 19 2 9 & 1 9 2 7 S HI C K O R Y S T . , SA N T A A N A , C A 92 7 0 7 NE W D E T A C H E D AD U SCALE: 1/4" = 1'-0"1 PROPOSED ELECTRICAL PLAN N RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N 1927 & 1929 S Hickory St2/12/2025 Geotechnical Investigation Report FOR: 1929 S. Hickory St. Santa Ana, CA 92707 SCOPE OF WORK: Soils Report for Proposed Detached ADU, Engineer: Ehab Elias 24881 Alicia Pkwy, Ste E-#222 Laguna Hills, CA 92653 1927 & 1929 S Hickory St2/12/2025 In accordance with the requirements of the City of Santa Ana this soils report has been prepared for the proposed project. Follow is a summary of our findings, conclusions and recommendations. Site Description and Proposed Development The subject property is located on the easterly side of Hickory St, south of Occidental St, north of Saint Andrew Place, east of Main Street, west of Standard Avenue, south of Edinger Avenue and north of Warner Avenue. A one-story house exists at the site. Based on the Site Plan prepared by the designer, we understand that the proposed ADU will be located in the front yard area. Note: The front yard area where the proposed ADU will be located is currently covered with minor grass and concrete slab. Note to the geotechnical report reviewer: Please see the full-scale plans prepared by the architect/designer/civil engineer which are separately submitted to the City for review, for clarifications/details of the proposed development, as needed. The site is relatively flat; and we understand that minimal raw cut/fill is expected for the site. Geotechincal conditions Based on the published geologic map prepared by the California Division of Mines and Geology (CDMG), the site is located within a broad flat alluvium and colluvium area. One test hole has been drilled using a small diameter auger hand-operated drilling tool down to 5 ft deep. The approximate location of our test hole is depicted on the attached Site Plan. The geotechnical log of the test hole is included in Appendix B. Expansion index and atterberg limits test were performed, and the laboratory test results are also included in Appendix B. Based on our filed observation and testing, the near-ground surface soils at the site generally consisted of silty fine sand, damp to moist and have a very low expansion potential. It is noted that the subject site is a previously graded lot which was previously approved by the City of construction of the existing house; and the subject approved lot is also surrounded by previously approved lots where houses exist. Distress to the on-site and off-site existing houses due to deep-seated settlement of the underlying earth materials was not observed and or reported. Thefore, deep-seated settlement is not anticipated to be a problem for the proposed new structures. Therefore, drilling deeper test hole(s) substantial sampling and consolidation 1927 & 1929 S Hickory St2/12/2025 testing for verification of potential deep-seated settlement are not considered necessary and not performed for this project. The lowest bearing capacity of 1,500 psf. Is recommended to be used for the proposed new structures. Therefore, direct shear testing is not considered necessary and not performed for this project. For conservative purposes, Type V cement with concrete strength of 4,500 psi is recommended to be used for concrete in contact with the on-site soils. Therefore, sulfate content testing is not considered necessary and not performed for this proposed project. Problems of the underlying soils, if any have been previously properly treated and judged to be adequate for structural support, and approved by the City prior to construction of the existing house. In addition, for conservative purposes, remedial removal/ over-excavation and recompaction of the existing soils underlying the proposed new structure is recommended for this project. Therefore, conventional laboratory tests such as moisture content & in-situ density, grain-size analysis, etc. are not considered necessary and not performed for this project. Groundwater Free standing groundwater was not encountered in our 5 ft deep test hole. Free standing ground water was not reported to be an issue at the site and in the vicinity deep footing/excavation are not proposed for the site; therefore adverse effects due to groundwater are not anticipated for the proposed development. Historic groundwater levels have been recorded approximately 20’ to 25’ below ground surface. Note: it is not anticipated; however, if wet soils are encountered, removal of the wet soil and replacement with drier soils/cement slurry can be performed. In addition, if need crushed rock and or geogrid for bridging, etc. can also be used. This will be determine by the geotechnical consultant based on the exposed conditions during the excavations the site Seismicity The subject site is located in Southern California, which is a major earthquake-pr zone. Therefore, the owner(s) of this property should be aware of the seismic r associated with being located in this zone. The Soil Site Class D Default can be used for the soils underlying the subject site. The Seismic Design Category D can be used for the site. The following seismic parameters obtained from the computer program seismicmaps.org prepared by SEAOC [Structural Engineers Association California] in 1927 & 1929 S Hickory St2/12/2025 conjunction with California's Office of Statewide Health Planning Development [OSHPD]) in accordance with ASCE7-16 can be used for the site. · Fa= 1.2 · Fv=null* · Mapped Spectral Accelerations Values: o Ss= 1.278 (for the short period of 0.2 second) o S1=0.457 (for the 1-second period) Maximum Considered Earthquake Spectral Response Accelerations: o SMs FaSs=1.534 (for the short period of 0.2 second) o SM₁ = FvS = null* (for the 1-second period) Design Spectral Response Accelerations: · SDs= 2/3 SM,= 1.022 (for the short period of 0.2 second) · SD1 = 2/3 SM₁ = null* (for the 1-second period) · PGA=0.54 Please see ASCE 7-16, Section 11.4.8. Please see APPENDIX C for additional seismic parameters, as needed Note: In general, the structural consultant of record for this project should review the seismic parameters provided in this report and the 2022 CBC to evaluate the seismic design. Final selection of design coefficients should be made by the structural consultant based on the local laws and ordinances, expected structure response, and the desired level of conservatism. The civil/structural design engineer should consult with the project geotechnical consultant, if additional geotechnical information is needed for structural seismic design. Faults No active faults are known to exist within or near the site. The probability of primary surface rupture or deformation at the site is, therefore, considered very low. The site is not designated to be located within the Special Studies/Earthquake Zone under the Alquist-Priolo Special Studies Act. Liquefaction Potential Based on the State of California SEISMIC HAZARD ZONES Map, Anaheim Quadrangle, the subject site is located within a potential liquefaction zone. Therefore, the owner(s) of this property should be aware of the risks associated with the potential liquefaction such as structural distress due to the potential differential settlement caused by the potential liquefaction. 1927 & 1929 S Hickory St2/12/2025 Potential Consequences of Liquefaction or Secondary Liquefaction Included Hazards Potential consequences of liquefaction or secondary liquefaction included hazards generally consist of differential settlement (vertical deformations), lateral movement/lateral spreading (horizontal deformations), oscillation, and reduction in foundation soil-bearing capacity (bearing failure). A sloping condition or drainage or stream channel does not exist at the site; therefore, lateral movement/lateral spreading, oscillation, etc. due to potential liquefaction are not anticipated to be credible hazards for the proposed new structure. In general, based on our experience, differential settlement due to liquefaction (and reduction in foundation soil-bearing capacity) is roughly estimated to be about 1/4 inch (for a horizontal distance of 30 feet). We believe if the area would be "liquefied" in the future due to a very strong earthquake, the potential damage to the proposed new structure which will be properly structurally designed in accordance with the new up-to-date codes would be much less severe than the existing on-site structures and surrounding existing houses which have been previously structurally designed based on old codes (which are much less stringent thanhe current new codes). However, the owner(s) of this property should be aware of the potential damage to the new structure due to liquefaction. In summary, it should be recognized that structural mitigation may not reduce the potential of the soils to liquefy during an earthquake; and there will remain some risk that the new structure could still suffer damage if liquefaction occurs, during a very strong earthquake. Note: In accordance with the California Geological Survey (CGS), Special Publication (SP) 117A, a detailed site-specific liquefaction study is not required for this project, since the proposed new dwelling structure is not exceeding two-story and is not part of a development of four or more dwelling units. Slope Stability The site is a flat area; therefore, slope instability is not a concern for the proposed development. CONCLUSIONS AND RECOMMENDATIONS General Conclusions Construction of the proposed structure at the subject site is considered geotechnically feasible, provided the recommendations outlined in this report are implemented. 1927 & 1929 S Hickory St2/12/2025 Note: The conclusions and recommendations of this report are based on information as interpreted from our limited subsurface investigation. It is not anticipated but they should be revised accordingly if geotechnical conditions to be exposed during site preparation/ grading and construction significantly differ from our findings and interpretations. In general, a conventional shallow foundation can be used for support of the proposed structure. The following recommendations are considered minimum and may be superseded by more restrictive requirements of the architect, civil/structural engineer, building codes, or governing agencies. Geotechnical Impact on Neighboring Properties Adverse geotechnical impact of the proposed development on the neighboring properties is not anticipated, provided the recommendations outlined in this report are properly implemented. Site Preparation/Grading Over-excavation / remedial removal for the proposed first-floor with slab-on-grade area: To create a relatively uniform new engineered compacted fill layer for the proposed new structural slab-on-grade area, over-excavation and re-compaction of about 3 ft. deep (measured from the existing ground surface) of the existing on-site soils should be performed. The lateral limits of the over-excavation should be minimum equal to depth of removal (3 ft. in this case) beyond the outside perimeter of the proposed new structure. The existing rear yard area where the proposed accessory dwelling unit will be located is currently covered with (exterior) concrete slabs which will be removed to replace with new (interior) slabs-on-grade of the proposed ADU. Other Recommendations: The new fill/backfill soils should be free of organic matter and oversized materials, 4 inches or greater in diameter, placed in near-horizontal loose lifts not to exceed eight inches in thickness, and moisture conditioned to slightly over optimum moisture content prior to compaction. Imported soils, if any, should have a very low expansion potential and should be geotechnically observed/tested and accepted by the geotechnical consultant prior to using at the site. In general, grading at the site should be performed in accordance with the requirements of the City and under the geotechnical observation and testing of the project geotechnical consultant. The compaction criterion for fill and backfill materials is a minimum of 90% of the maximum density determined in accordance with ASTM Test Method D1557. 1927 & 1929 S Hickory St2/12/2025 Temporary Excavations In general, temporary excavations should be performed in accordance with OSHA requirements. In general, care should be taken during excavation near an existing structural object, if any to ensure no damage is done to the existing object. In general, based on our experience with many similar projects in the City of Santa Ana, temporary excavation next to existing building footings does not affect the existing footings. However, if needed, excavations in sections, about 10 to 15 ft. long can be performed. This will be determined by the geotechnical engineer of record based on the conditions to be exposed during excavation. The above temporary excavation recommendations can be changed by the geotechnical consultant based on conditions to be exposed in the field during excavations BUILDING FOUNDATION DESIGN GUIDELINES Geotechnical Parameters For Structural Design For conservative purposes, the following "lowest" code values should be used for structural design, as needed. A. Allowable vertical bearing earth pressure: 1,500 psf. An increase of one-third is permitted when using the combinations that include wind or earthquake loads. B. Lateral bearing passive earth pressure: 100 psf. per foot into competent materials below the finished ground surface. An increase of one third is permitted when using the alternative load combinations that include wind or earthquake loads. C. Lateral Sliding Resistance: cohesion = 130 psf. The cohesion value is to be multiplied by the contact area. In no case shall the lateral sliding resistance exceed one-half the dead load. D. Soil unit weight: 120 pcf. New Building Footings In general, the foundation system for the proposed structure must be properly designed by the civil/structural design engineer of record for this project and reviewed and approved by the city prior to construction. The adequacy for support of the proposed structure of the existing footings should be evaluated by the civil/structural design engineer of record for this project. Underpinning footings can be provided, if needed. 1927 & 1929 S Hickory St2/12/2025 New building footings should be embedded minimum 24-inches below the adjacent lowest finished grade. Minimum widths for isolated columns/pad footings, if any, should be 24-inches, and for continuous wall footings should be 12-inches for one-story and 15- inches for two story portions. Minimum reinforcement for new continuous footings should be two #5 re-bars at top and two #5 re-bars at bottom. Settlement Distress to the existing house due to settlement of the underlying soils was not observed. Therefore, deep-seated settlement of the soils underlying the site is not considered to be a concern for the proposed development. In general, based on our experience, the conventional total settlement of ½ inch and a differential settlement of ¼ inch over a horizontal distance of 30 feet are anticipated for the proposed new structure and would occur during the construction stage. New (Interior) Building Slabs-on-Grade New (interior) building slabs-on-grade should be minimum 5 inches thick, reinforced with #4 re- bars at 16 inches on centers, or equivalent, placed at mid-height of the slab. New slabs should be underlain by a 2-inch thick layer of clean sand. For moisture sensitive floor areas, the new slabs should be underlain by a 10-mil polyethylene moisture barrier membrane (such as Visqueen). The moisture barrier membrane should be properly lapped and sealed at joints and around any breaks such as openings for utility conduits. Note: CAL Green Code, and/or other applicable codes/City's requirements should govern and be followed. The entire slab-on-grade system including the capillary break / vapor/moisture retarder should be properly designed by the project civil /structural design engineer of record (but not by the geotechnical engineer) and reviewed and approved by the City prior to construction. New Exterior Slabs-on-Grade To reduce the potential for excessive cracking, new exterior concrete slabs-on-grade, if any, should be minimum 4 inches thick, provided with construction or weakened plane joints at frequent intervals (e. g., every 6 feet or less). Provision of a 2-inch thick layer of crushed rock, gravel, or clean sand to be placed beneath the slabs and/or reinforcement, such as #3 re-bars at 24 inches on-centers, or equivalent, placed at the mid-height of the slab should be considered. The subgrade soils for the exterior slabs should be properly re- compacted. Slab Subgrade Pre-Saturation The conventional pre-saturation of subgrade soils to minimum 140% of the optimum moisture content to minimum 24 inches deep is not considered necessary for this project. However, spraying with water should be performed prior to concrete pour. 1927 & 1929 S Hickory St2/12/2025 Other Recommendations for Reducing Slab Cracking While not a geotechnical issue, the potential for slab cracking may also be reduced by careful control of water/cement ratio and stump of concrete. The contractor should take appropriate curing precautions during the pouring of concrete in hot weather to reduce racking of slabs. A slip sheet (or equivalent) can be utilized if grouted tile, marble tile, or other crack sensitive floor covering is planned directly on concrete slabs. New Driveway The minimum section required by the City can be used for a new driveway, if any, It there is no minimum requirements by the City, a 5-inch thick concrete slab (PCC) reinforced with #4 rebar (placed at mid-height of slaba) at 18 inches on centers both ways, or S-in. thick asphalt concrete (AC), or equivalent, over a 6-inch thick layer of aggregate base (AB) can be used. The aggregate base and subgrade should be properly compacted to a minimum of 95% and 90%, respectively, of the maximum density determined in accordance with ASTM D1557 prior to placement of the concrete slab Spraying the compacted subgrade soils with water should be performed prior to comerete pour If pavers are to be used, they must be properly designed by the civil engineer of record for this project and approved by the city prior to construction. Additional geotechnic data can be provided for design, if requested. Site Drainage In general, proper surface drainage should be checked, improved as needed, maintained to ensure surface water flows away from all structures. Requirements by city and applicable CBC (2022 CBC) should also be followed. Roof gutters should be properly provided. Roof drains, gutters and downspouts should maintained to function as intended. Outlet drains should be kept open. Irrigation at the site, if any, should be kept to a minimum required to support plant life. In the future, sources of uncontrolled water, such as leaky sewer, water (domestic irrigation) or drainpipe, should be repaired if identified. Seismic Design We recommend the proposed new structure be structurally designed to meet applicable building codes and requirements of the controlling governmental agency. The seismic parameters provided in the "Seismicity" section of this report can be used. The civil/structural design engineer should consult with the project geotechnical consultant, if additional geotechnical information is needed for the seismic design. Cement Type For Concrete in Contact with On-Site Earth Materials 1927 & 1929 S Hickory St2/12/2025 Our previous tests performed on the soils of many lots in the City of Garden Grove which are similar to the on-site soils show negligible water soluble sulfate contents. Sulfate attack on concrete was not observed for the existing on-site house and other houses in the surrounding areas. It appears sulfate attack on concrete is not a problem in the City of Santa Ana. However, for conservative purposes, Type V cement with a maximum water/cement ratio of 0.45 and a minimum concrete strength, fe of 4,500 psi is recommended to be used for concrete in contact with the on-site soils. Additional water- soluble sulfate content testing can be performed for the soils at the site, as needed. The test can be conducted during and/or after completion of site preparation/grading. The applicable California Building Code (2022 CBC) and other requirements by controlling governmental agencies should be followed. Corrosion To Ferrous Metals and Copper For conservative purposes, the on-site soils can be considered severely corrosive to ferrous metals and copper. Underground/buried ferrous metals or copper are not planned to be used for this project. However, if underground/buried ferrous metals or copper are planned to be used at the site, they should be properly protected. A corrosion specialist can be consulted. Testing can be performed for verification of the potential corrosion of the soils at the site to ferrous metals and copper, if needed. The test can be performed during and/or after completion of grading. Geotechnical Review of Grading and Foundation Plans Based on the City's requirements, the project geotechnical consultant should review, "approve" and sign the project grading and foundation plans with details/specifications, if any, indicating conformation to applicable geotechnical recommendations. We will corporate with the civil/structural design engineers who prepare the plans to ensure our geotechnical recommendations are properly incorporated into the plans. Geotechnical Observation and Testing During Construction We recommend that a qualified geotechnical consultant be retained to provide geotechnical engineering services, including geotechnical observation/testing, during the construction phase of the project. This is to verify the compliance with the design, specifications and/or recommendations, and to allow design changes in the event that subsurface conditions differ from those anticipated. Geotechnical observation/testing can be performed at the following stages: · During ANY grading operations, including excavation, removal, filling and backfilling, etc. 1927 & 1929 S Hickory St2/12/2025 · During and after excavation for footings to verify the adequacy of underlying materials. · After pre-saturation of slab subgrade earth materials, if any, prior to pouring concrete. · After compaction of subgrade soils and/or aggregate base for exterior slabs and or driveway, if any. · During backfill of drainage and utility line trenches, if any, to verify proper compaction. · When/If any unusual geotechnical conditions are encountered. Note: If Geotechnical International is not provided the opportunity to perform the geotechnical observation/testing during the construction phase, Geotechnical International will take no responsibility for the conclusions and recommendations contained in our report in the event that subsurface conditions differ from those interpreted and anticipated during our preliminary investigation phase prior to the start of construction. CLOSURE The conclusion and recommendations contained in this report are presented based on geotechnical data as described herein which are believed representative of the total project area. However, earth materials can vary in characteristics, both laterally and vertically, and those variations could affect the conclusions and recommendations contained herein. As such, observation and testing by a qualified geotechnical consultant during the construction phase of the project are essential to confirming the basis of this report. This report has been prepared consistent with that level of care being provided by other professionals providing similar services at the locale and time period. The contents of this report are professional opinions and as such, are not to be considered a guaranty or warranty. This report should be reviewed and updated after a period of one year or if the lot ownership or site conditions / proposed development change from that described herein. The following are attached and complete our report: Appendix A - References Appendix B-Geotechnical Log of Test Hole and Laboratory Test Results Appendix C-Seismic Data Figure 1 - Vicinity Map Figure 2-Site Plan/Geotechnical Map 1927 & 1929 S Hickory St2/12/2025 If you have any questions or require clarification, please contact this office. This opportunity to be of service is sincerely appreciated. 1927 & 1929 S Hickory St2/12/2025 REFERENCES 1. California division of mines and geology (CDMG), the Resources Agency, Dept. of Conservation, 1981, “Geology Map of Orange County Showing Mines and Mineral Deposits”, scale 1:48,000, 1”= 4000’, or 1”=0.76 miles, prepared in corporation with Count of Orange EMA, complied by P.K. Morton and R.V. Miller , dated 1981 2. California Division of Mines and Geology (CDMG), Department of Conservation, 1997, 1998, “Seismic Hazard Zones, Anaheim Quadrangle”, Scale 1:24,000 (1”=2,000 ft or 1”=0.38 miles), released April 15, 1998. 3. U.S.G.S., United States Department of Interior, Geological Survey, 1965, 1981, “Topographic Map, Anaheim Quadrangle, California,-Orange Co.”, 7.5 Minute Series, scale 1:24,000 (1”24,000 (1” = 2000ft or 1”=0.38 mile, dated 1965, photo-revised 1981 4. CDMG, 1997, Seismic Hazard Zone, Report 03, Seismic Hazard Zone Report for the Anaheim and Newport each 7.5 – Minute Quadrangles, Orange County, California” dated 1997. 1927 & 1929 S Hickory St2/12/2025 APPENDIX B GEOTECHINCAL LOG OF TEST HOLE AND LABORATORY TEST RESULTS 1927 & 1929 S Hickory St2/12/2025 GEOTECHNICAL LOG OF TEST HOLE Date: June 28, 2023 Project No. Barnett Hole Diameter: 4 +/- inches Depth Description 1’-3’ +/- Gray silty fine sand, damp to moist, medium dense. 3’ – end Light gray silty fine sand, moist, medium dense. Total depth: 5 ft +/- No Caving No Free Standing Groundwater Hole back-filled with on site soils 1927 & 1929 S Hickory St2/12/2025 EXPANSION INDEX TEST RESULTS Sample location TH-1 @0’-3’ Compacted Dry Density (pcf) 107.0 Moisture content/compacted Final 10.5/18.7 Expansion Index 0 Expansion Potential Classification Very Low Test Method: ASTM D4829 1927 & 1929 S Hickory St2/12/2025 ATTERBERG LIMITS TEST RESULTS Sample location TH-1 @0’-3’ Liquid Limit Sandy, could not perform the test Plastic Limit Plasticity Index Test Method: ASTM D4318 1927 & 1929 S Hickory St2/12/2025 APPENDIX C SEISMIC DATA 1927 & 1929 S Hickory St2/12/2025          !"!"!#$$%$#$&'()*+&   $$#$!,-! ./0/121345678912:;12<=:<1>=<;1?>1/0@A@;1B2> C<:4:DEF;1C7=G4:DEFH1IIJ@00K@A.;1L..@JMKA0N/O P<:F  PFQ4G=1?7EF1RFSF8F=5F1P75DTF=: UVWX R4Q61?<:FG789 YY 24:F1?Z<QQ W"#$[   \] ^9_F `<ZDF PFQ584_:47=   UVa#! [" !!]  b UVa#! [" !]  b\ W!"!$$ $# #$$W    W!"!$$ $#    c#! $# ! #$$W    c#! $# ! ^9_F `<ZDF PFQ584_:47= U #$$W    !d e  $"" ! e #$$W    $"" ! f  b UV,#!$ ef   $""f f  X !"!,#!$ gh  hW!!! ag   f$,W!#! [ !]  i  \\ e!#"Wj![k$d"-!bd]$$   X\ e!!$ $# [ !] ag  b f$,W!#! [ !]  i  l\ e!#"Wj![k$d"-!bd]$$   X e!!$ $# [ !] f !  XX e!!$ $# [f,#! $] f i  b "Wj![k$d"-!bd]f,#! $ Ua  l\ ! $#",""! Ua l ! $#",""!" Um  \bX m$"" 1927 & 1929 S Hickory St2/12/2025            ! "#$%&&#'%& (( )*%%&++&#,#&#,$+, -#%&#+#%& +%#%+$,$#+.%'$$+,+&#,%#&#,&,#%$#  (( )*%%+$$ #+%/+%$+$#'.%0#%$#%$+&+$%%$1+%$+$#%#,+#$ %'%%&,&  $$$&+###&#,$++  $++$&%#,'#&,'&+#%%&%&#$&+#%% '#%$&+#%%&%&,#+%#+%#+#$& 1927 & 1929 S Hickory St2/12/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area: Area to be Added: Total Resulting Area: Stories: Area Added in Past 2 Years (excluding this project): Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability (PR400-402) Fire Sprinkler 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has fire sprinklers or a house that will have fire sprinklers added as part of this project? (PR400-402) Fire Sprinkler 3.   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than 140-feet from the fire access roadway? *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all enclosed spaces, such as garages, stairs, and detached structures separated by less than 10-feet? *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed contractor to determine if a fire sprinkler modification is needed. (PR400-402) Fire Sprinkler 7.   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold set by local ordinance? *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 sf, and ADU’s). *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as defined by the State, or (D) near an area that could be affected by a wildfire in the open space. *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR 1927 & 1929 S Hickory St2/12/2025 STRUCTURAL CALCULATIONS FOR: 1929 S. Hickory St. Santa Ana, CA SCOPE OF WORK: Detached ADU Engineer: Ehab Elias 24752 Via Balboa Laguna Hills CA, 92653 1927 & 1929 S Hickory St2/12/2025 CODE: 2019 CALIFORNIA BUILDING CODE WITH LOCAL ADDENDA Timber Douglas Fir Larch Rafters & Joints: #2 Grade Beams & Headers: As noted on plans Concrete F c’ = 2,500 PSI @ 28 days Reinforcing Steel ASTM A-615 #4 & Smaller, Grade #5 & Larger, Grade Soil Value 1,500 PSF per Soils IBC Typical Weights: Item PSF R-38 INS 1.5 ½ Gyp Board 2.2 Roofing (Shingles) 3.0 2x4 @ 16” O.C 1.1 2x6 @ 16” O.C 1.7 2x6 @ 24” O.C 2.3 2x8 @ 24” O.C 1.5 ½ Plywood 1.5 Stucco (7/8) 10.0 R-13 0.5 R-19 0.8 2x10 @ 16” O.C. 3.0 2x10 @ 24” O.C. 2.0 2x12 @ 16” O.C. 3.3 2x12 @ 24” O.C. 2.4 14” TJI Joist 4.2 TPO Roofing 0.5 ¾ Plywood 3.0 Rigid Fiberglass (1” thick) 1.5 5/8 Gyp Board 2.8 5/8 Gyp Type X 3.0 2x4 Interior Walls 10.0 1927 & 1929 S Hickory St2/12/2025 3/8” Plywood 1.1 5/8” Plywood 1.8 ¾” Plywood 2.2 Glasss Wool 0.2 Ceramic Tile, ¾” 10.0 Wood Paneling 2.5 Clay Roof Tile 6.5 Hardie Board 2.3 1927 & 1929 S Hickory St2/12/2025 LOADS Wall Loads (Exterior) 2x4 @ 16 1.1 ½ CDX Plywood 1.5 ½ Gyp Board 2.5 R-13 0.5 Siding 10.0 TOTAL 15.6+MISC = 17 DEAD LOAD Roof Loads Asphalt Shingles 3 Framing 2x6 @ 16 O.C. 1.7 Roofing Paper 0.3 ½ Plywood 1.5 TOTAL 6.5 = 7 PSF Dead Load 20 PSF Live Load Ceiling Loads R-38 1.5 Framing 2x6 @ 16 O.C. 1.7 DryWall 2.2 TOTAL 5.4 = 6 PSF Dead Load 10 PSF Live Load 1927 & 1929 S Hickory St2/12/2025 SEISMIC DESIGN 1927 & 1929 S Hickory St2/12/2025          !"!"!#$$%$#$&'()*+&   $$#$!,-! ./0/121345678912:;12<=:<1>=<;1?>1/0@A@;1B2> C<:4:DEF;1C7=G4:DEFH1IIJ@00K@A.;1L..@JMKA0N/O P<:F  PFQ4G=1?7EF1RFSF8F=5F1P75DTF=: UVWX R4Q61?<:FG789 YY 24:F1?Z<QQ W"#$[   \] ^9_F `<ZDF PFQ584_:47=   UVa#! [" !!]  b UVa#! [" !]  b\ W!"!$$ $# #$$W    W!"!$$ $#    c#! $# ! #$$W    c#! $# ! ^9_F `<ZDF PFQ584_:47= U #$$W    !d e  $"" ! e #$$W    $"" ! f  b UV,#!$ ef   $""f f  X !"!,#!$ gh  hW!!! ag   f$,W!#! [ !]  i  \\ e!#"Wj![k$d"-!bd]$$   X\ e!!$ $# [ !] ag  b f$,W!#! [ !]  i  l\ e!#"Wj![k$d"-!bd]$$   X e!!$ $# [ !] f !  XX e!!$ $# [f,#! $] f i  b "Wj![k$d"-!bd]f,#! $ Ua  l\ ! $#",""! Ua l ! $#",""!" Um  \bX m$"" 1927 & 1929 S Hickory St2/12/2025            ! "#$%&&#'%& (( )*%%&++&#,#&#,$+, -#%&#+#%& +%#%+$,$#+.%'$$+,+&#,%#&#,&,#%$#  (( )*%%+$$ #+%/+%$+$#'.%0#%$#%$+&+$%%$1+%$+$#%#,+#$ %'%%&,&  $$$&+###&#,$++  $++$&%#,'#&,'&+#%%&%&#$&+#%% '#%$&+#%%&%&,#+%#+%#+#$& 1927 & 1929 S Hickory St2/12/2025 sheet no.:A2 Project:1929 Hickory ROOF: roof DL= 10 psf partitions=5 psf W roof=15 psf 2ND FLOOR:floor DL=0 psf partitions=0 psf w floor=0 psf W Total=15 psf Latitude;33.72267 longitude:-117.8602 Ss 1.278 S1 0.457 Site Class:D Risk Category:II ASCE 7 Table 1.5-1 Ie=1 ASCE 7 Table 1.5-2 Fa=1.2 SMS 1.534 SDS 1.022 D ASCE 7 Table 11.6-1 rho=1.3 Plywood Shear Walls 6.5 ASCE 7 Table 12.2-1 Base Shear Coefficient SDS*I/R=Cs=0.157 (Strength) 0.7SDS*I/R Cs=0.110 (Service) V=CsW=V=2.77 psf Seismic Calcs 15 lb/sf Lb 1012 sf 10,251 lb 134 ft 4.5 ft 17 lb/sf 25,431 lb 2.77 lb/sf Wind Load Calcs 9.6 lb/sf L=44 7,603 lb W=23 3,974 lb Wind Load= Wind Pressure x Wall Height x L x 2= Wind Load= Wind Pressure x Wall Height x W x 2= Celing Heigh / 2 = Wall Wight = Wtotal= Wroof + Wwall = V = Cs x Wtotal/Bld Area = Wind Pressure (16 lb/sf) x 0.6 Wroof = Bld. Area x Roof SF weight= Bld. Area= 15,180 Wwall = Bld. Circumference x (ceiling heigh/2)x wall wight per LF Bld. Circumference = Importance Factor: Site Coefficient: EQUIVALENT LATERAL FORCE PROCEDURE (ASCE 7 Section 12.8): Site Spectural Accel Value Design Response: Seismic Design Category: Redundancy Factor Seismic Force Resisting System Response Modification Factor LATERAL ANALYSIS (ASCE 7-16) STORY WEIGHTS: SEISMIC: Maximum Short Period Response: maximum 1 sec. Period Response: 1927 & 1929 S Hickory St2/12/2025 sheet no.:A3 Project:1929 Hickory 2.77 psf Mbal= ((0.6-0.14SDS)xDL) X L^2/2 Seismic Wall NO. Lw Total (ft) HW (FT) Trib. Area (sf) V (pounds) Add'l Shear V/L (plf) **Wall Type Smallest DL (plf) OTM (ft-lbs) Mbal (ft- lbs) Uplift (lbs) Simpson Holdown 1 12 9 510 1411 118 2 2 100 2116 91 1012 HDU2 2 12 9 510 1411 118 2 2 100 2116 91 1012 HDU2 WIND: Wall NO. Lw Total (ft) HW (FT) Trib. Area (sf)V/L (PLF) **Wall Type Smallest OTM (ft-lbs) RM (ft- lbs) Uplift (lbs) Simpson Holdown 1 12 9 510 319 2 2 5747 342 2771 HDU2 2 12 9 510 319 2 2 5747 342 2771 HDU2 OTM= OTM= (V/L (plf x Lw) x Hw RM= RM= (Wall DL(psf) x Lw x Hw) x (Lw/2) T&C= T&C= (OTM - (0.6*RM))/Lw Seismic Wall NO.Lw Total HW Trib. Area V Add'l V/L (plf)**Wall Smallest DL (plf)OTM Mbal (ft-Uplift Simpson A 12 9 510 1411 118 1 2 100 2116 91 1012 HDU2 B 12 9 510 1411 118 1 2 100 2116 91 1012 HDU2 WIND: Wall NO.Lw Total HW Trib. Area V/L (PLF)**Wall Smallest OTM RM (ft-Uplift Simpson A 12 9 510 167 1 2 3004 342 1400 HDU2 B 12 9 510 167 1 2 3004 342 1400 HDU2 Wall type Nailing Capaciy (plf) Simpson Hold Down Capacity (lbs) 1 8d at 6" o.c. 260 HDU2 2306 2 8d at 4" o.c. 380 Wall 1,2,A,B HDU4 3424 Wall 1,2,A,B 3 8d at 3" o.c. 490 HDU5 4234 *Capacities have been reduce by 25% DESIGN LATERAL FORCES ON SHEAR WALLS Roof Diaphragm Shear= Cs X 1.0= See pg 17 for revised West SW calc 1927 & 1929 S Hickory St2/12/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2127 @ 2"8181 (3.50")Passed (26%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1788 @ 1' 1"5922 Passed (30%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)6874 @ 6' 9 1/2"9307 Passed (74%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.199 @ 6' 9 1/2"0.442 Passed (L/801)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.345 @ 6' 9 1/2"0.663 Passed (L/460)--1.0 D + 1.0 L (All Spans) Member Length : 13' 7" System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD All Product Solutions Depth Series Plies Cost Index 11 7/8"1 3/4" 1.55E TimberStrand® LSL 1 32.21 * 9 1/2"6 x DF No.1 1 83.60 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. SOLUTIONS REPORT PASSED The purpose of this report is for product comparison only. Load and support information necessary for professional design review is not displayed here. Please print an individual Member Report for submittal purposes. Level, Ceiling Flush Beam Current Solution: 1 piece(s) 6 x 10 DF No.1 ForteWEB Software Operator Job Notes 4/8/2024 2:17:53 PM UTC Ehab Elias Structural Ventures (760) 484-6343 eliasehab@gmail.com ForteWEB v3.7, Engine: V8.4.0.40, Data: V8.1.5.0 File Name: Hickory Page 1 / 1 1927 & 1929 S Hickory St2/12/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)243 @ 2 1/2"2231 (3.50")Passed (11%)--1.0 D + 1.0 L (All Spans) Shear (lbs)218 @ 9"990 Passed (22%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)836 @ 7' 3 1/2"819 Passed (102%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.513 @ 7' 3 1/2"0.708 Passed (L/332)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.854 @ 7' 3 1/2"0.944 Passed (L/199)--1.0 D + 1.0 L (All Spans) Member Length : 14' 7" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor/Ceiling Live Factored Accessories 1 - Stud wall - SPF 3.50"3.50"1.50"97 146 243 Blocking 2 - Stud wall - SPF 3.50"3.50"1.50"97 146 243 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)6" o/c Bottom Edge (Lu)14' 7" o/c • Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. Dead Floor/Ceiling Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 14' 7"16"10.0 15.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Level, Ceiling: Attic Joist 1 piece(s) 2 x 6 DF No.1 @ 16" OC ForteWEB Software Operator Job Notes 4/8/2024 2:15:23 PM UTC Ehab Elias Structural Ventures (760) 484-6343 eliasehab@gmail.com ForteWEB v3.7, Engine: V8.4.0.40, Data: V8.1.5.0 File Name: Hickory Page 1 / 1 1927 & 1929 S Hickory St2/12/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)300 @ 2 1/2"2231 (3.50")Passed (13%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)266 @ 8 11/16"1238 Passed (21%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)884 @ 6' 3 1/2"1178 Passed (75%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.413 @ 6' 3 1/2"0.641 Passed (L/372)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.740 @ 6' 3 1/2"0.855 Passed (L/208)--1.0 D + 1.0 Lr (All Spans) Member Length : 13' 5" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 4/12 All Product Solutions Depth Series Plies Spacing Cost Index 5 1/2"1 3/4" 1.55E TimberStrand® LSL 1 19.2"0.78 * 5 1/2"2 x DF No.1 1 16"0.88 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. SOLUTIONS REPORT PASSED The purpose of this report is for product comparison only. Load and support information necessary for professional design review is not displayed here. Please print an individual Member Report for submittal purposes. Level, Roof: Joist Current Solution: 1 piece(s) 2 x 6 DF No.1 @ 16" OC ForteWEB Software Operator Job Notes 4/8/2024 2:16:18 PM UTC Ehab Elias Structural Ventures (760) 484-6343 eliasehab@gmail.com ForteWEB v3.7, Engine: V8.4.0.40, Data: V8.1.5.0 File Name: Hickory Page 1 / 1 1927 & 1929 S Hickory St2/12/2025 RESUBMITTAL CALCULATIONS 1927 & 1929 S Hickory St2/12/2025 Force to North Wall Line 1996 lb (seismic) L shearwall 16.0 ft L total 43.5 ft v line 46 plf v wall 125 plf delta 79 plf Drag Force (positon in feet from end of house) Position (ft)Force (lb) 0 0 12 946 16 763 (8 x 141 x 1.6 x 1.5/1.62 = 1,671 lb) 20 1078 =755 lb (ASD)(8) 16d TOP PLATE SPLICE GOOD FOR 1,671 lb OK 31 574 =401 lb (ASD)CS20 W/ 10d NAILING GOOD FOR 1,030 lb OK 43.5 0 west RE-ENTRANT CORNER LOCATION DRAG ANALYSIS AT NORTH WALL / RE-ENTRANT CORNER 2X8 CJ @16" 2X 6 C J & R R 4X 6 H E A D E R HE A D E R 4X 6 H E A D E R 4X 6 H E A D E R 4X6 HEADER 4X6 HEADER 4X4 POST 4X4 POST 8 SD1 8 SD1 2X8 R 2 2 2 2X10 RIDGE 8' 2' - 0 " 2' - 0 " SIMP. CS20 STRAP W/ 10d NAILING OVER 3x4 FLAT BLKG. 4' - 0 " M I N . 1' - 0 " M I N . 4 1927 & 1929 S Hickory St2/12/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1377 @ 0 3281 (1.50")Passed (42%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)1134 @ 8 3/4"3806 Passed (30%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)2840 @ 4' 1 1/2"3737 Passed (76%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.110 @ 4' 1 1/2"0.275 Passed (L/901)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.196 @ 4' 1 1/2"0.313 Passed (L/506)--1.0 D + 1.0 Lr (All Spans) Member Length : 8' 3" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (5/16"). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Trimmer - DF 1.50"1.50"1.50"603 773 1377 None 2 - Trimmer - DF 1.50"1.50"1.50"603 773 1377 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' 3" o/c Bottom Edge (Lu)8' 3" o/c Dead Roof Live Vertical Loads Location Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)0 to 8' 3"N/A 6.4 -- 1 - Uniform (PSF)0 to 8' 3"6'15.8 20.0 Roof 2 - Uniform (PSF)0 to 8' 3"4' 6"10.0 15.0 Ceiling Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Roof, Wall: Garage Header 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 11/15/2024 3:55:20 AM UTC ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: Hickory Page 1 / 1 1927 & 1929 S Hickory St2/12/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4121 @ 2"12031 (3.50")Passed (34%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)3382 @ 1' 1"7402 Passed (46%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)11773 @ 6' 1/2"11634 Passed (101%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.263 @ 6' 1/2"0.587 Passed (L/537)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.465 @ 6' 1/2"0.783 Passed (L/303)--1.0 D + 1.0 Lr (All Spans) Member Length : 12' 1" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •Lumber grading provisions must be extended over the length of the member per NDS 4.2.5.5. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"1795 2326 4121 Blocking 2 - Column - DF 3.50"3.50"1.50"1795 2326 4121 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)6" o/c Bottom Edge (Lu)12' 1" o/c • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)0 to 12' 1"N/A 13.2 -- 1 - Uniform (PSF)0 to 12' 1" (Front)11'15.8 20.0 Roof 2 - Uniform (PSF)0 to 12' 1" (Front)11'10.0 15.0 Ceiling Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Roof, Roof: Living Room Flush Beam 1 piece(s) 6 x 10 DF No.1 ForteWEB Software Operator Job Notes 11/15/2024 4:05:19 AM UTC ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: Hickory Page 1 / 1 1927 & 1929 S Hickory St2/12/2025 Wall ID: Assumptions •Allowable Stress Design •Load Combos: D + 0.6W D + 0.75(0.6W) + 0.75Lr (1.0 + 0.14SDS)D + 0.7E 0.6D + 0.6W (0.6 - 0.14SDS)D + 0.7E Vertical Loads w: plf a: ft wp:plf b: ft P1:lb c: ft P2:lb d: ft P3:lb e:ft wwall:psf Lateral Loads VE:lb VW:lb SDS:g Wall Dimensions Wall Length, L:ft Floor-to-Roof Height, h: ft Roof Framing Height, f: ft Nominal wall width: Curb height: in Plywood/OSB Sheathing Sheathing Layers:0.7vE:plf 15/32" Sheathing Panels Sheathing Grade:0.6vW :plf One side of wall Sheathing Thickness:vallowable:plf (seismic) OK Edge Nails: 8d @ 6'' OC Minimum Nail Size:vallowable:plf (wind) OK Field Nails: 8d @ 12'' OC Wall Aspect Ratio: < 2:1, OK Check Bundled Studs or Posts at Wall Ends for Compression Size, Species, & Grade: Unbraced Height & Slenderness Ratio: Load Case: Axial Load, Pa: Axial Stress, fc: Allowable Stress, F'c: Check Axial: Allowable Bearing, F'cp: Check Sill Crushing: Check Holdowns at Each Wall End Member & Thickness at Holdown: Holdown & Capacity: Load Case: Uplift, Ta: Check Uplift: One-Story Wood Shear Wall Design West Wall D Lr 15 20 0 0 0 8 0 0 0 0 0 0 0 0 0 17 1996 1996 1.022 8 10 1 4x 0 One side of wall 175 Sheathing 150 260 8d 365 15/32" 1.1:1 4x4 DF-L #2 4x4 DF-L #2 Left Post Right Post Seismic Wind Seismic Wind 8.625 ft 30 < 50 OK 8.625 ft 30 < 50 OK 625 psi 625 psi 625 psi 625 psi 625 > 143 OK 625 > 122 OK 625 > 143 OK 625 > 122 OK 518 psi 518 psi 518 psi 518 psi 518 > 143 OK 518 > 122 OK 518 > 143 OK 518 > 122 OK 1,747 lb 1,497 lb 1,747 lb 1,497 lb 143 psi 122 psi 143 psi 122 psi 1,439 lb 1,094 lb 1,439 lb 1,094 lb OK OK OK OK HDU2-SDS2.5 3,075 lb HDU2-SDS2.5 3,075 lb Seismic Wind Seismic Wind Left Holdown Right Holdown 4x4 b = 3.5 in 4x4 b = 3.5 in 1927 & 1929 S Hickory St2/12/2025 One-Story Shear Wall Grade Beam Design (page 1) Vertical Loads w: plf a: ft wp:plf b: ft P1:lb c: ft P2:lb d: ft P3:lb g: ft wwall:psf i: ft wA:plf j: ft wB:plf k: ft PA:lb m: ft PB:lb n: ft Lateral Loads (Strength) VE:lb VW:lb SDS:g h: ft Grade Beam Properties slab depth: in GB depth: in A: ft dtop bars: in slab width: ft GB width: in B: ft dbott bars: in slab weight:k f'c:ksi lw:ft Allow. Soil Brg:ksf GB Weight:k fy (long.):ksi ltotal:ft Allow. Soil Brg:ksf @ 1.33x fy (stirrups): ksi Stability and Soil Pressure Check ------- LOAD CASE 1 : DL --------- --------LOAD CASE 2 : D+L ---------USE 12.0 W X 24.0 D GRD BM Total Weight = 9.3 k Total Weight = 9.5 k W/2-#5 TOP & 2-#5 BOT FORCES FROM THE RIGHT FORCES FROM THE RIGHT 0.90*M(R)= 54 ft-k > M (OT) O.K. 0.90*M(R)= 55 ft-k > M (OT) O.K. Reaction Pt. = 3.3 ft:outside 1/3 Reaction Pt. = 3.3 ft:outside 1/3 Soil Press (Max @ A) = 1.89 < 2.00 OK Soil Press (Max @ A) = 1.90 < 2.00 OK +Mu (X1) = 70 in-k +Mu (X1) = 71 in-k -Mu (X2) = 32 in-k -Mu (X2) = 32 in-k FORCES FROM THE LEFT FORCES FROM THE LEFT 0.90*M(R)= 54 ft-k > M (OT) O.K. 0.90*M(R)= 55 ft-k > M (OT) O.K. Reaction Pt. = 3.3 ft:outside 1/3 Reaction Pt. = 3.3 ft:outside 1/3 Soil Press (Max @ B) = 1.89 < 2.00 OK Soil Press (Max @ B) = 1.90 < 2.00 OK +Mu (X2) = 70 in-k +Mu (X2) = 71 in-k -Mu (X1) = 32 in-k -Mu (X1) = 32 in-k ------------------------LOAD CASE 3 : DUCTILITY ------------------------- Design for:Ωo = a. Maximum anticipated forces: Ωo * M(OT) = k-ft Occurs when Ωo * M(OT) < 0.90*M(R)TL b. Maximum force that can be delivered to the system: Occurs when Ωo * M(OT) >0.90*M(R)TL +Mu = Total Wt*(X)*1.4 FORCES FROM THE LEFT FORCES FROM THE RIGHT 0.90*M(R)= 50 ft-k < M (OT) 0.90*M(R)= 50 ft-k < M (OT) Reaction Pt. = 0.0 ft: Reaction Pt. = 0.0 ft: +Mu (X2) = 346 in-k +Mu (X1) = 346 in-k -Mu (X1) = 32 in-k -Mu (X2) = 32 in-k 0 0 0.00 17 0.00 0 0 0.00 0 0 0.00 D Lr 15 20 0.00 0 0 8.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 6 12 2.50 20 4.1 3.0 8.0 1.50 10.00 5 24 2.50 20 1996 1996 1.022 2.5 72 3.9 60 13.0 2.00 40 1927 & 1929 S Hickory St2/12/2025 One-Story Shear Wall Grade Beam Design (page 2) Reinforcing Check Top Longitudinal Bars USE 12.0 W X 24.0 D GRD BM From Load Cases 1 & 2 :W/2-#5 TOP & 2-#5 BOT -Mu max = 32 in-k ==> -As req = 0.03 in^2 < 200/Fy = 0.80 in^2 -As req times 1.33 = 0.04 in^2 -As req < 200/Fy : Therefore Ductility requirements indicated above need to be checked. From Load Case 3 : -Mu max = 32 in-k (same as Load Cases 1 & 2) From Load Cases 1 & 2 : -As req = 0.04 in^2 <---CONTROLS From Load Case 3 : -As req = 0.03 in^2 With 200/Fy : -As req = 0.80 in^2 Note : Less than 200/Fy Reinforcing can be used since Grade Beam will remain elastic under Maximum Anticipated Forces. With: TOP : -As = 0.62 in^2 > 0.04 in^2 øMn = 649 in-k Bottom Longitudinal Bars From Load Cases 1 & 2 : +Mu max = 71 in-k ==> +As req = 0.07 in^2 < 200/Fy = 0.80 in^2 +As req times 1.33 = 0.09 in^2 +As req < 200/Fy : Therefore Ductility requirements indicated above need to be checked. From Load Case 3 : +Mu max = 346 in-k ==> +As req = 0.33 in^2 From Load Cases 1 & 2 : +As req = 0.09 in^2 From Load Case 3 : +As req = 0.33 in^2 <---CONTROLS With 200/Fy : +As req = 0.80 in^2 Note : Less than 200/Fy Reinforcing can be used since Grade Beam will remain elastic under Maximum Anticipated Forces. With: BOT : +As = 0.62 in^2 > 0.33 in^2 øMn = 649 in-k Shear Vu max = 1 k øVc/2 = 11 k > Vu Stirrups Not Required (2) #5 (2) #5 1927 & 1929 S Hickory St2/12/2025 SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa-ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Thai Viet Phan COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez David Penaloza Jessie Lopez Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org ACTING CITY MANAGER Alvaro Nuñez CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall July 18, 2024 Also sent via email to: Alansgc@gmail.com Alan Chen 1929 South Hickory Street Santa Ana, CA 92707 Subject: Address Assignment (1927 South Hickory Street) for a New Accessory Dwelling Unit located at 1929 South Hickory Street (APN: 014-101-13) in Santa Ana, CA Dear Alan, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a new Accessory Dwelling Unit to be assigned 1927 South Hickory Street located at 1929 South Hickory Street (APN: 014-101-13). Notice is hereby given that the following assigned address(es) shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Existing Address(es) Address(es) to be Activated/Posted 1929 South Hickory Street 1927 South Hickory Street (Address for New ADU) To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 667-2754 or by email at MSmith10@santa-ana.org. Sincerely, Mikael Smith Planning Technician Exhibit A – Address Plan 1927 & 1929 S Hickory St2/12/2025 Address Letter for 1927 South Hickory Street Page 2 of 3 c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Mishele Richards, Orange County Fire Authority, GEO Files Coordinator Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Will Holt, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Mirella Vargas, Customer Service Representative Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Alvaro Nunez, PBA Assistant Director and Code Enforcement Manager 1927 & 1929 S Hickory St2/12/2025 Address Letter for 1927 South Hickory Street Page 3 of 3 EXHIBIT A: ADDRESS PLAN ADU) 1927 South Hickory Street (EXISTING) 1929 Hickory Street 1927 & 1929 S Hickory St2/12/2025 Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)-647-5800 www.santa-ana.org GRADING PERMIT REQUIREMENTS FOR DETACHED ADU PROJECTS PCC-15 REV: 09/03/2020 Page 1 of 1 A grading permit is required for all new detached buildings including new detached Accessory Dwelling Unit (ADU) projects. Grading plans prepared and stamped by a registered professional engineer shall be submitted for approval prior to issuance of the building permit, and shall be required to be submitted before or concurrently with the architectural plans submittal to the Building Safety Division. Grading Permit Exemption: Residential detached Accessory Dwelling Unit (ADU) projects that meet all of the following may be exempted from grading permit requirements: 1. The maximum amount of soil being moved is less than 50 cubic yards. The soil quantities shall be calculated by a California registered professional civil engineer 2. A site drainage plan prepared by a California registered professional civil engineer shall be provided with the following minimum information, but not limited to: a. Plan(s) shall be stamped, signed and dated by a California registered civil engineer b. Location of all existing and proposed structures, property lines, right-of-way lines, and easements, including dimensions and setbacks c. Drainage slopes and flow patterns d. Drainage system such as swales, french drains, water collection and disposal system, etc. e. Drainage plan shall indicate how the site grading or drainage system will manage all surface water flows to be diverted away from buildings and adjoining property lines, in accordance with all applicable codes f. The grade shall fall not fewer than 6 inches within the first 10 feet from the foundation wall. Where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, drains, or swales shall be constructed to ensure drainage away from the structure. Impervious surfaces within 10 feet of the building foundation shall be sloped not less than 2 percent away from the building. 3. A final certification letter from the professional engineer of record stating that the grades were constructed per the approved site drainage plan, shall be submitted to the building inspector prior to final inspection 4. The “Detached ADU Grading Permit Exemption Checklist” shall be completed by the California registered professional civil engineer and shall be made a part of the building plans. 5. The site drainage plan and the completed checklist shall be required at the time of architectural plans submittal as part of the building plans package. The building official reserves the right to require a grading plan based on site conditions. This grading permit exemption does not apply to projects in the FEMA Flood Zone. 1927 & 1929 S Hickory St2/12/2025 Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)-647-5800 www.santa-ana.org DETACHED ADU - GRADING PERMIT EXEMPTION CHECKLIST PCC-16 REV: 11/10/2020 Page 1 of 1 THIS FORM SHALL BE COMPLETED BY A CALIFORNIA REGISTERED CIVIL ENGINEER. Instructions: In order to qualify for the grading permit exemption for detached Accessory Dwelling Unit (ADU) projects per handout PCC-15, the registered civil engineer of record shall complete all sections, check all boxes and sign the certification section below. A copy of this checklist shall be attached to each of TWO sets of plans. If answering NO to any of the questions, a grading plan and permit shall be required. Project Address: Yes No 1. ☐ ☐ I have verified that the project address is NOT located on a FEMA designated flood zone (Zone A or AE). 2. ☐ ☐ I have provided two sets of site drainage plans that is stamped, signed and dated by a California professional civil engineer, to be submitted with the building submittal package. 3. ☐ ☐ I have calculated the total amount of soil being cut or filled on this project is less than 50 cubic yards. 4. ☐ ☐ The site drainage plans include the following, but not limited to, location of all existing and proposed structures, property lines, right-of-way lines, and easements, including dimensions and setbacks; drainage slopes and flow patterns, drainage systems such as swales, french drains, water collection and disposal systems, etc. 5. ☐ ☐ I have designed drainage such that surface water flows away from buildings and adjoining property lines, in accordance with all applicable codes. 6. ☐ ☐ I have designed grading such that it will not adversely affect the adjoining properties. 7. ☐ ☐ I have designed the grade to fall not fewer than 6 inches within the first 10 feet from the foundation walls except where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, I have designed drains or swales to ensure drainage away from the buildings. Any impervious surfaces within 10 feet of the building foundation are sloped not less than 2 percent away from the building. 8. ☐ ☐ I will provide a final certification letter stating that the grades were constructed per the approved site drainage plan, and will submit this certification letter to the building inspector prior to final inspection. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Licensed Number: Date: Phone Number: Email Address: 1927 & 1929 S Hickory St2/12/2025 Lawyers Title Company 16755 Von Karman Avenue Suite 100 Irvine, CA 92606 Phone: (949) 223-5575 Fax: ( ) ALAN SHAO GUANG CHEN 4132 WILLIWAW DRIVE IRVINE, CALIFORNIA 92620 January 14, 2022 YOUR REF: 21-4894-SN OUR NO.: 221534503 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 Property: 1929 South Hickory Street, Santa Ana, California Dear Customer: Attached please find your ALTA Homeowner’s 2013 Policy of title insurance. NOTE: Your policy is a computer generated product. Although lacking color and “live” signatures, it is the original of your policy. Thank you for selecting Lawyers Title Company for your transactional management needs. Enclosure 1927 & 1929 S Hickory St2/12/2025 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 This policy has been issued through the offices of Lawyers Title Company 16755 Von Karman Avenue Suite 100 Irvine, CA 92606 Phone: (949) 223-5575 Fax: ( ) We wish to take this opportunity to thank you for allowing us to assist you in your recent real estate transaction. We appreciate your confidence in us and take pride in our ability to service all your title needs. The enclosed title policy was carefully prepared in accordance with your agent’s instruction and should be kept in a safe place with your other important documents as it continues to protect you as long as you have an interest in the subject real property. We hope we can be of assistance to you in all your future real estate transactions. Cordially, James M. John 1927 & 1929 S Hickory St2/12/2025 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 ALTA Homeowner’s Policy of Title Insurance (12-2-13) Page 1 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. HHOOMMEEOOWWNNEERR’’SS PPOOLLIICCYY OOFF TTIITTLLEE IINNSSUURRAANNCCEE FFoorr aa oonnee--ttoo--ffoouurr ffaammiillyy rreessiiddeennccee Issued by Commonwealth Land Title Insurance Company OWNER’S INFORMATION SHEET Your Title Insurance Policy is a legal contract between You and Us. It applies only to a one-to-four family residence and only if each insured named in Schedule A is a Natural Person. If the Land described in Schedule A of the Policy is not an improved residential lot on which there is located a one-to-four family residence, or if each insured named in Schedule A is not a Natural Person, contact Us immediately. The Policy insures You against actual loss resulting from certain Covered Risks. These Covered Risks are listed beginning on page 3 of the Policy. The Policy is limited by: • Provisions of Schedule A • Exceptions in Schedule B • Our Duty To Defend Against Legal Actions On Page 7 • Exclusions on page 8 • Conditions on page 9. You should keep the Policy even if You transfer Your Title to the Land. It may protect against claims made against You by someone else after You transfer Your Title. IF YOU WANT TO MAKE A CLAIM, SEE SECTION 3 UNDER CONDITIONS ON PAGE 10. The premium for this Policy is paid once. No additional premium is owed for the Policy. This sheet is not Your insurance Policy. It is only a brief outline of some of the important Policy features. The Policy explains in detail Your rights and obligations and Our rights and obligations. Since the Policy – and not this sheet – is the legal document, YOU SHOULD READ THE POLICY VERY CAREFULLY. If You have any questions about Your Policy, contact: Commonwealth Land Title Insurance Company, P.O. Box 45023, Jacksonville, FL 32232-5023 1927 & 1929 S Hickory St2/12/2025 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 ALTA Homeowner’s Policy of Title Insurance (12-2-13) Page 2 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. HHOOMMEEOOWWNNEERR’’SS PPOOLLIICCYY OOFF TTIITTLLEE IINNSSUURRAANNCCEE FFoorr aa oonnee--ttoo--ffoouurr ffaammiillyy rreessiiddeennccee Issued by Commonwealth Land Title Insurance Company TABLE OF CONTENTS OWNER'S COVERAGE STATEMENT ...................................................................................................................... 3 COVERED RISKS ...................................................................................................................................................... 3 OUR DUTY TO DEFEND AGAINST LEGAL ACTIONS .......................................................................................... 7 EXCLUSIONS ............................................................................................................................................................ 8 CONDITIONS 1. Definitions .............................................................................................................................................. 9 2. Continuation of Coverage ........................................................................................................................ 9 3. How to Make a Claim ............................................................................................................................. 10 4. Our Choices When We Learn of a Claim ................................................................................................. 10 5. Handling a Claim or Legal Action ........................................................................................................... 11 6. Limitation of Our Liability ...................................................................................................................... 11 7. Transfer of Your Rights to Us ................................................................................................................. 12 8. This Policy is the Entire Contract ............................................................................................................ 13 9. Increased Policy Amount......................................................................................................................... 13 10. Severability ............................................................................................................................................. 13 11. Arbitration .............................................................................................................................................. 13 12. Choice of Law ........................................................................................................................................ 13 SCHEDULE A ............................................................................................................................................................ 14 Policy Number, Premium, Date and Time and Amount Deductible Amounts and Maximum Dollar Limits of Liability Street Address of the Land 1. Name of Insured 2. Interest in Land Covered 3. Description of the Land SCHEDULE B – EXCEPTIONS ................................................................................................................................. 16 1927 & 1929 S Hickory St2/12/2025 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 ALTA Homeowner’s Policy of Title Insurance (12-2-13) Page 3 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. HHOOMMEEOOWWNNEERR’’SS PPOOLLIICCYY OOFF TTIITTLLEE IINNSSUURRAANNCCEE FFoorr aa oonnee--ttoo--ffoouurr ffaammiillyy rreessiiddeennccee Issued by Commonwealth Land Title Insurance Company As soon as You Know of anything that might be covered by this Policy, You must notify Us promptly in writing at the address shown in Section 3 of the Conditions. OWNER'S COVERAGE STATEMENT This Policy insures You against actual loss, including any costs, attorneys’ fees and expenses provided under this Policy. The loss must result from one or more of the Covered Risks set forth below. This Policy covers only Land that is an improved residential lot on which there is located a one-to-four family residence and only when each insured named in Schedule A is a Natural Person. Your insurance is effective on the Policy Date. This Policy covers Your actual loss from any risk described under Covered Risks if the event creating the risk exists on the Policy Date or, to the extent expressly stated in Covered Risks, after the Policy Date. Your insurance is limited by all of the following: • The Policy Amount • For Covered Risk 16, 18, 19 and 21, Your Deductible Amount and Our Maximum Dollar Limit of Liability shown in Schedule A • The Exceptions in Schedule B • Our Duty To Defend Against Legal Actions • The Exclusions on page 8 • The Conditions on page 9. COVERED RISKS The Covered Risks are: 1. Someone else owns an interest in Your Title. 2. Someone else has rights affecting Your Title because of leases, contracts, or options. 3. Someone else claims to have rights affecting Your Title because of forgery or impersonation. 4. Someone else has an easement on the Land. 5. Someone else has a right to limit Your use of the Land. 6. Your Title is defective. Some of these defects are: a. Someone else’s failure to have authorized a transfer or conveyance of your Title. b. Someone else’s failure to create a valid document by electronic means. c. A document upon which Your Title is based is invalid because it was not properly signed, sealed, acknowledged, delivered or recorded. d. A document upon which Your Title is based was signed using a falsified, expired, or otherwise invalid power of attorney. 1927 & 1929 S Hickory St2/12/2025 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 ALTA Homeowner’s Policy of Title Insurance (12-2-13) Page 4 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. e. A document upon which Your Title is based was not properly filed, recorded, or indexed in the Public Records. f. A defective judicial or administrative proceeding. 7. Any of Covered Risks 1 through 6 occurring after the Policy Date. 8. Someone else has a lien on Your Title, including a: a. lien of real estate taxes or assessments imposed on Your Title by a governmental authority that are due or payable, but unpaid; b. Mortgage; c. judgment, state or federal tax lien; d. charge by a homeowner’s or condominium association; or e. lien, occurring before or after the Policy Date, for labor and material furnished before the Policy Date. 9. Someone else has an encumbrance on Your Title. 10. Someone else claims to have rights affecting Your Title because of fraud, duress, incompetency or incapacity. 11. You do not have actual vehicular and pedestrian access to and from the Land, based upon a legal right. 12. You are forced to correct or remove an existing violation of any covenant, condition or restriction affecting the Land, even if the covenant, condition or restriction is excepted in Schedule B. However, You are not covered for any violation that relates to: a. any obligation to perform maintenance or repair on the Land; or b. environmental protection of any kind, including hazardous or toxic conditions or substances unless there is a notice recorded in the Public Records, describing any part of the Land, claiming a violation exists. Our liability for this Covered Risk is limited to the extent of the violation stated in that notice. 13. Your Title is lost or taken because of a violation of any covenant, condition or restriction, which occurred before You acquired Your Title, even if the covenant, condition or restriction is excepted in Schedule B. 14. The violation or enforcement of those portions of any law or government regulation concerning: a. building; b. zoning; c. land use; d. improvements on the Land; e. land division; or f. environmental protection, if there is a notice recorded in the Public Records, describing any part of the Land, claiming a violation exists or declaring the intention to enforce the law or regulation. Our liability for this Covered Risk is limited to the extent of the violation or enforcement stated in that notice. 1927 & 1929 S Hickory St2/12/2025 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 ALTA Homeowner’s Policy of Title Insurance (12-2-13) Page 5 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. 15. An enforcement action based on the exercise of a governmental police power not covered by Covered Risk 14 if there is a notice recorded in the Public Records, describing any part of the Land, of the enforcement action or intention to bring an enforcement action. Our liability for this Covered Risk is limited to the extent of the enforcement action stated in that notice. 16. Because of an existing violation of a subdivision law or regulation affecting the Land: a. You are unable to obtain a building permit; b. You are required to correct or remove the violation; or c. someone else has a legal right to, and does, refuse to perform a contract to purchase the Land, lease it or make a Mortgage loan on it. The amount of Your insurance for this Covered Risk is subject to Your Deductible Amount and Our Maximum Dollar Limit of Liability shown in Schedule A. 17. You lose Your Title to any part of the Land because of the right to take the Land by condemning it, if: a. there is a notice of the exercise of the right recorded in the Public Records and the notice describes any part of the Land; or b. the taking happened before the Policy Date and is binding on You if You bought the Land without Knowing of the taking. 18. You are forced to remove or remedy Your existing structures, or any part of them – other than boundary walls or fences – because any portion was built without obtaining a building permit from the proper government office. The amount of Your insurance for this Covered Risk is subject to Your Deductible Amount and Our Maximum Dollar Limit of Liability shown in Schedule A. 19. You are forced to remove or remedy Your existing structures, or any part of them, because they violate an existing zoning law or zoning regulation. If You are required to remedy any portion of Your existing structures, the amount of Your insurance for this Covered Risk is subject to Your Deductible Amount and Our Maximum Dollar Limit of Liability shown in Schedule A. 20. You cannot use the Land because use as a single-family residence violates an existing zoning law or zoning regulation. 21. You are forced to remove Your existing structures because they encroach onto Your neighbor’s land. If the encroaching structures are boundary walls or fences, the amount of Your insurance for this Covered Risk is subject to Your Deductible Amount and Our Maximum Dollar Limit of Liability shown in Schedule A. 22. Someone else has a legal right to, and does, refuse to perform a contract to purchase the Land, lease it or make a Mortgage loan on it because Your neighbor’s existing structures encroach onto the Land. 23. You are forced to remove Your existing structures which encroach onto an easement or over a building set-back line, even if the easement or building set-back line is excepted in Schedule B. 24. Your existing structures are damaged because of the exercise of a right to maintain or use any easement affecting the Land, even if the easement is excepted in Schedule B. 1927 & 1929 S Hickory St2/12/2025 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 ALTA Homeowner’s Policy of Title Insurance (12-2-13) Page 6 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. 25. Your existing improvements (or a replacement or modification made to them after the Policy Date), including lawns, shrubbery or trees, are damaged because of the future exercise of a right to use the surface of the Land for the extraction or development of minerals, water or any other substance, even if those rights are excepted or reserved from the description of the Land or excepted in Schedule B. 26. Someone else tries to enforce a discriminatory covenant, condition or restriction that they claim affects Your Title which is based upon race, color, religion, sex, handicap, familial status, or national origin. 27. A taxing authority assesses supplemental real estate taxes not previously assessed against the Land for any period before the Policy Date because of construction or a change of ownership or use that occurred before the Policy Date. 28. Your neighbor builds any structures after the Policy Date – other than boundary walls or fences – which encroach onto the Land. 29. Your Title is unmarketable, which allows someone else to refuse to perform a contract to purchase the Land, lease it or make a Mortgage loan on it. 30. Someone else owns an interest in Your Title because a court order invalidates a prior transfer of the title under federal bankruptcy, state insolvency, or similar creditors’ rights laws. 31. The residence with the address shown in Schedule A is not located on the Land at the Policy Date. 32. The map, if any, attached to this Policy does not show the correct location of the Land according to the Public Records. 1927 & 1929 S Hickory St2/12/2025 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 ALTA Homeowner’s Policy of Title Insurance (12-2-13) Page 7 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. OUR DUTY TO DEFEND AGAINST LEGAL ACTIONS We will defend Your Title in any legal action only as to that part of the action which is based on a Covered Risk and which is not excepted or excluded from coverage in this Policy. We will pay the costs, attorneys' fees, and expenses We incur in that defense. We will not pay for any part of the legal action which is not based on a Covered Risk or which is excepted or excluded from coverage in this Policy. We can end Our duty to defend Your Title under Section 4 of the Conditions. THIS POLICY IS NOT COMPLETE WITHOUT SCHEDULES A AND B. Countersigned By: Approved Officer or Agent 1927 & 1929 S Hickory St2/12/2025 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 ALTA Homeowner’s Policy of Title Insurance (12-2-13) Page 8 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. EXCLUSIONS In addition to the Exceptions in Schedule B, You are not insured against loss, costs, attorneys' fees, and expenses resulting from: 1. Governmental police power, and the existence or violation of those portions of any law or government regulation concerning: a. building; b. zoning; c. land use; d. improvements on the Land; e. land division; and f. environmental protection. This Exclusion does not limit the coverage described in Covered Risk 8.a., 14, 15, 16, 18, 19, 20, 23 or 27. 2. The failure of Your existing structures, or any part of them, to be constructed in accordance with applicable building codes. This Exclusion does not limit the coverage described in Covered Risk 14 or 15. 3. The right to take the Land by condemning it. This Exclusion does not limit the coverage described in Covered Risk 17. 4. Risks: a. that are created, allowed, or agreed to by You, whether or not they are recorded in the Public Records; b. that are Known to You at the Policy Date, but not to Us, unless they are recorded in the Public Records at the Policy Date; c. that result in no loss to You; or d. that first occur after the Policy Date - this does not limit the coverage described in Covered Risk 7, 8.e., 25, 26, 27 or 28. 5. Failure to pay value for Your Title. 6. Lack of a right: a. to any land outside the area specifically described and referred to in paragraph 3 of Schedule A; and b. in streets, alleys, or waterways that touch the Land. This Exclusion does not limit the coverage described in Covered Risk 11 or 21. 7. The transfer of the Title to You is invalid as a preferential transfer or as a fraudulent transfer or conveyance under federal bankruptcy, state insolvency, or similar creditors’ rights laws. 8. Contamination, explosion, fire, flooding, vibration, fracturing, earthquake, or subsidence. 9. Negligence by a person or an Entity exercising a right to extract or develop minerals, water, or any other substances. 1927 & 1929 S Hickory St2/12/2025 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 ALTA Homeowner’s Policy of Title Insurance (12-2-13 ) Page 9 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. HHOOMMEEOOWWNNEERR’’SS PPOOLLIICCYY OOFF TTIITTLLEE IINNSSUURRAANNCCEE FFoorr aa oonnee--ttoo--ffoouurr ffaammiillyy rreessiiddeennccee Issued by Commonwealth Land Title Insurance Company CONDITIONS 1. DEFINITIONS a. Easement – the right of someone else to use the Land for a special purpose. b. Estate Planning Entity – A legal entity or Trust established by a Natural Person for estate planning. c. Known – things about which You have actual knowledge. The words “Know” and “Knowing” have the same meaning as Known. d. Land – the land or condominium unit described in paragraph 3 of Schedule A and any improvements on the Land which are real property. e. Mortgage – a mortgage, deed of trust, trust deed or other security instrument. f. Natural Person – a human being, not a commercial or legal organization or entity. Natural Person includes a trustee of a Trust even if the trustee is not a human being. g. Policy Date – the date and time shown in Schedule A. If the insured named in Schedule A first acquires the interest shown in Schedule A by an instrument recorded in the Public Records later than the date and time shown in Schedule A, the Policy Date is the date and time the instrument is recorded. h. Public Records – records that give constructive notice of matters affecting Your Title, according to the state statutes where the Land is located. i. Title – the ownership of Your interest in the Land, as shown in Schedule A. j. Trust – a living trust established by a Natural Person for estate planning. k. We/Our/Us – Commonwealth Land Title Insurance Company l. You/Your – the insured named in Schedule A and also those identified in Section 2.b. of these Conditions. 2. CONTINUATION OF COVERAGE a. This Policy insures You forever, even after You no longer have Your Title. You cannot assign this Policy to anyone else. b. This Policy also insures: (1) anyone who inherits Your Title because of Your death; (2) Your spouse who receives Your Title because of dissolution of Your marriage; (3) the trustee or successor trustee of Your Trust or any Estate Planning Entity created for You to whom or to which You transfer Your Title after the Policy Date; (4) the beneficiaries of Your Trust upon Your death; or (5) anyone who receives Your Title by a transfer effective on Your death as authorized by law. 1927 & 1929 S Hickory St2/12/2025 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 ALTA Homeowner’s Policy of Title Insurance (12-2-13 ) Page 10 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. c. We may assert against the insureds identified in Section 2.b. any rights and defenses that We have against any previous insured under this Policy. 3. HOW TO MAKE A CLAIM a. Prompt Notice Of Your Claim (1) As soon as You Know of anything that might be covered by this Policy, You must notify Us promptly in writing. (2) Send Your notice to Commonwealth Land Title Insurance Company, Attention: Claims Department, P.O. Box 45023, Jacksonville, FL 32232-5023. Please include the Policy number shown in Schedule A, and the county and state where the Land is located. Please enclose a copy of Your policy, if available. (3) If You do not give Us prompt notice, Your coverage will be reduced or ended, but only to the extent Your failure affects Our ability to resolve the claim or defend You. b. Proof Of Your Loss (1) We may require You to give Us a written statement signed by You describing Your loss which includes: (a) the basis of Your claim; (b) the Covered Risks which resulted in Your loss; (c) the dollar amount of Your loss; and (d) the method You used to compute the amount of Your loss. (2) We may require You to make available to Us records, checks, letters, contracts, insurance policies and other papers which relate to Your claim. We may make copies of these papers. (3) We may require You to answer questions about Your claim under oath. (4) If you fail or refuse to give Us a statement of loss, answer Our questions under oath, or make available to Us the papers We request, Your coverage will be reduced or ended, but only to the extent Your failure or refusal affects Our ability to resolve the claim or defend You. 4. OUR CHOICES WHEN WE LEARN OF A CLAIM a. After We receive Your notice, or otherwise learn, of a claim that is covered by this Policy, Our choices include one or more of the following: (1) Pay the claim; (2) Negotiate a settlement; (3) Bring or defend a legal action related to the claim; (4) Pay You the amount required by this Policy; (5) End the coverage of this Policy for the claim by paying You Your actual loss resulting from the Covered Risk, and those costs, attorneys’ fees and expenses incurred up to that time which We are obligated to pay; (6) End the coverage described in Covered Risk 16, 18, 19 or 21 by paying You the amount of Your insurance then in force for the particular Covered Risk, and 1927 & 1929 S Hickory St2/12/2025 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 ALTA Homeowner’s Policy of Title Insurance (12-2-13 ) Page 11 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. those costs, attorneys’ fees and expenses incurred up to that time which We are obligated to pay; (7) End all coverage of this Policy by paying You the Policy Amount then in force, and those costs, attorneys' fees and expenses incurred up to that time which We are obligated to pay; (8) Take other appropriate action. b. When We choose the options in Sections 4.a. (5), (6) or (7), all Our obligations for the claim end, including Our obligation to defend, or continue to defend, any legal action. c. Even if We do not think that the Policy covers the claim, We may choose one or more of the options above. By doing so, We do not give up any rights. 5. HANDLING A CLAIM OR LEGAL ACTION a. You must cooperate with Us in handling any claim or legal action and give Us all relevant information. b. If You fail or refuse to cooperate with Us, Your coverage will be reduced or ended, but only to the extent Your failure or refusal affects Our ability to resolve the claim or defend You. c. We are required to repay You only for those settlement costs, attorneys' fees and expenses that We approve in advance. d. We have the right to choose the attorney when We bring or defend a legal action on Your behalf. We can appeal any decision to the highest level. We do not have to pay Your claim until the legal action is finally decided. e. Whether or not We agree there is coverage, We can bring or defend a legal action, or take other appropriate action under this Policy. By doing so, We do not give up any rights. 6. LIMITATION OF OUR LIABILITY a. After subtracting Your Deductible Amount if it applies, We will pay no more than the least of: (1) Your actual loss; (2) Our Maximum Dollar Limit of Liability then in force for the particular Covered Risk, for claims covered only under Covered Risk 16, 18, 19 or 21; or (3) the Policy Amount then in force. and any costs, attorneys’ fees and expenses that We are obligated to pay under this Policy. b. If We pursue Our rights under Sections 4.a.(3) and 5.e. of these Conditions and are unsuccessful in establishing the Title, as insured: (1) the Policy Amount then in force will be increased by 10% of the Policy Amount shown in Schedule A, and (2) You shall have the right to have the actual loss determined on either the date the claim was made by You or the date it is settled and paid. c. (1) If We remove the cause of the claim with reasonable diligence after receiving notice of it, all Our obligations for the claim end, including any obligation for loss You had while We were removing the cause of the claim. (2) Regardless of 6.c.(1) above, if You cannot use the Land because of a claim covered by this Policy: (a) You may rent a reasonably equivalent substitute residence and We will repay You for the actual rent You pay, until the earlier of: 1927 & 1929 S Hickory St2/12/2025 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 ALTA Homeowner’s Policy of Title Insurance (12-2-13 ) Page 12 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. (i) the cause of the claim is removed; or (ii) We pay You the amount required by this Policy. If Your claim is covered only under Covered Risk 16, 18, 19 or 21, that payment is the amount of Your insurance then in force for the particular Covered Risk. (b) We will pay reasonable costs You pay to relocate any personal property You have the right to remove from the Land, including transportation of that personal property for up to twenty-five (25) miles from the Land, and repair of any damage to that personal property because of the relocation. The amount We will pay You under this paragraph is limited to the value of the personal property before You relocate it. d. All payments We make under this Policy reduce the Policy Amount then in force except for costs, attorneys' fees and expenses. All payments We make for claims which are covered only under Covered Risk 16, 18, 19 or 21 also reduce Our Maximum Dollar Limit of Liability for the particular Covered Risk, except for costs, attorneys’ fees and expenses. e. If We issue, or have issued, a Policy to the owner of a Mortgage that is on Your Title and We have not given You any coverage against the Mortgage, then: (1) We have the right to pay any amount due You under this Policy to the owner of the Mortgage, and any amount paid shall be treated as a payment to You under this Policy, including under Section 4.a. of these Conditions; (2) Any amount paid to the owner of the Mortgage shall be subtracted from the Policy Amount then in force; and (3) If Your claim is covered only under Covered Risk 16, 18, 19 or 21, any amount paid to the owner of the Mortgage shall also be subtracted from Our Maximum Dollar Limit of Liability for the particular Covered Risk. f. If You do anything to affect any right of recovery You may have against someone else, We can subtract from Our liability the amount by which You reduced the value of that right. 7. TRANSFER OF YOUR RIGHTS TO US a. When We settle Your claim, We have all the rights and remedies You have against any person or property related to the claim. You must not do anything to affect these rights and remedies. When We ask, You must execute documents to evidence the transfer to Us of these rights and remedies. You must let Us use Your name in enforcing these rights and remedies. b. We will not be liable to You if We do not pursue these rights and remedies or if We do not recover any amount that might be recoverable. c. We will pay any money We collect from enforcing these rights and remedies in the following order: (1) to Us for the costs, attorneys’ fees and expenses We paid to enforce these rights and remedies; (2) to You for Your loss that You have not already collected; (3) to Us for any money We paid out under this Policy on account of Your claim; and (4) to You whatever is left. d. If You have rights and remedies under contracts (such as indemnities, guaranties, bonds or other policies of insurance) to recover all or part of Your loss, then We have all of those rights and remedies, even if those contracts provide that those obligated have all of Your rights and remedies under this Policy. 1927 & 1929 S Hickory St2/12/2025 POLICY NO.: CA-FXDD-ICL-81451-1-22-221534503 ALTA Homeowner’s Policy of Title Insurance (12-2-13 ) Page 13 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. 8. THIS POLICY IS THE ENTIRE CONTRACT This Policy, with any endorsements, is the entire contract between You and Us. To determine the meaning of any part of this Policy, You must read the entire Policy and any endorsements. Any changes to this Policy must be agreed to in writing by Us. Any claim You make against Us must be made under this Policy and is subject to its terms. 9. INCREASED POLICY AMOUNT The Policy Amount then in force will increase by ten percent (10%) of the Policy Amount shown in Schedule A each year for the first five years following the Policy Date shown in Schedule A, up to one hundred fifty percent (150%) of the Policy Amount shown in Schedule A. The increase each year will happen on the anniversary of the Policy Date shown in Schedule A. 10. SEVERABILITY If any part of this Policy is held to be legally unenforceable, both You and We can still enforce the rest of this Policy. 11. ARBITRATION a. If permitted in the state where the Land is located, You or We may demand arbitration. b. The law used in the arbitration is the law of the state where the Land is located. c. The arbitration shall be under the Title Insurance Arbitration Rules of the American Land Title Association (“Rules”). You can get a copy of the Rules from Us. d. Except as provided in the Rules, You cannot join or consolidate Your claim or controversy with claims or controversies of other persons. e. The arbitration shall be binding on both You and Us. The arbitration shall decide any matter in dispute between You and Us. f. The arbitration award may be entered as a judgment in the proper court. 12. CHOICE OF LAW The law of the state where the Land is located shall apply to this policy. 1927 & 1929 S Hickory St2/12/2025 ALTA Homeowner’s Policy of Title Insurance (12-2-13 ) Page 14 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. HOMEOWNER’S POLICY OF TITLE INSURANCE For a one-to-four family residence SCHEDULE A Name and Address of Title Insurance Company: Lawyers Title Company 16755 Von Karman Avenue Suite 100 Irvine, CA 92606 Order No.: 221534503-130-NN Policy No.: CA-FXDD-ICL-81451-1-22-221534503 Premium: $1,608.00 Policy Amount: $480,000.00 Policy Date and Time: January 05, 2022 at 08:00 AM Deductible Amounts and Maximum Dollar Limits of Liability For Covered Risk 16, 18, 19 and 21: Your Deductible Amount Our Maximum Dollar Limit of Liability Covered Risk 16: 1.00% of Policy Amount Shown in Schedule A or $2,500.00 (whichever is less) $ 10,000.00 Covered Risk 18: 1.00% of Policy Amount Shown in Schedule A or $5,000.00 (whichever is less) $ 25,000.00 Covered Risk 19: 1.00% of Policy Amount Shown in Schedule A or $5,000.00 (whichever is less) $ 25,000.00 Covered Risk 21: 1.00% of Policy Amount Shown in Schedule A or $2,500.00 (whichever is less) $ 5,000.00 Street Address of the Land: 1929 South Hickory Street, Santa Ana, California 1. Name of Insured: Alan Shao Guang Chen, a married man as his sole and separate property and Wayne Yong Guang Chen, a single man, as joint tenants 2. Your interest in the Land covered by this Policy is: A Fee 3. The Land referred to in this policy is described as follows: See Exhibit A attached hereto and made a part hereof. 1927 & 1929 S Hickory St2/12/2025 Policy No.: CA-FXDD-ICL-81451-1-22-221534503 File No.: 221534503-130-NN ALTA Homeowner’s Policy of Title Insurance (12-2-13 ) Page 15 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. EXHIBIT A LEGAL DESCRIPTION THE LAND REFERRED TO HEREIN IS SITUATED IN THE COUNTY OF ORANGE, STATE OF CALIFORNIA, AND IS DESCRIBED AS FOLLOWS: LOT 6 IN BLOCK 4 OF TRACT NO. 560, IN THE CITY OF SANTA ANA, COUNTY OF ORANGE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 19, PAGES 1 AND 2 OF MISCELLANEOUS MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. EXCEPT THEREFROM ALL OIL, GAS, MINERALS AND OTHER HYDROCARBON SUBSTANCES LYING BELOW A DEPTH OF 500 FEET FROM THE SURFACE OF SAID PROPERTY BUT WITH NO RIGHT OF SURFACE ENTRY, AS PROVIDED IN DEEDS OF RECORD. ASSESSOR'S PARCEL NUMBER: 014-101-13 1927 & 1929 S Hickory St2/12/2025 Policy No.: CA-FXDD-ICL-81451-1-22-221534503 File No.: 221534503-130-NN ALTA Homeowner’s Policy of Title Insurance (12-2-13 ) Page 16 Copyright American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA Licensees and ALTA Members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. HOMEOWNER’S POLICY OF TITLE INSURANCE For a one-to-four family residence Issued By Commonwealth Land Title Insurance Company SCHEDULE B EXCEPTIONS In addition to the Exclusions, You are not insured against loss, costs, attorneys’ fees, and expenses resulting from: A. Property taxes, which are a lien not yet due and payable, including any assessments collected with taxes to be levied for the fiscal year 2022-2023. B. The lien of supplemental or escaped assessments of property taxes, if any, made pursuant to the provisions of Chapter 3.5 (commencing with Section 75) or Part 2, Chapter 3, Articles 3 and 4, respectively, of the Revenue and Taxation Code of the State of California as a result of the transfer of title to the vestee named in Schedule A or as a result of changes in ownership or new construction occurring prior to Date of Policy. 1. Water rights, claims or title to water, whether or not disclosed by the Public Records. 2. Easement(s) for the purpose(s) shown below and rights incidental thereto as set forth in a document: Purpose: Telephone and Electric Light Poles, Wires and Conduits, Water Pipes, Sewer and Gas Mains Recording Date: January 7, 1925 Recording No.: Book 559, Page 24, of Deeds Affects: said land more particularly described therein 3. Covenants, conditions and restrictions but omitting any covenants or restrictions, if any, including but not limited to those based upon race, color, religion, sex, gender, gender identity, gender expression, sexual orientation, marital status, national origin, ancestry, familial status, source of income, disability, veteran or military status, genetic information, medical condition, citizenship, primary language, and immigration status, as set forth in applicable state or federal laws, except to the extent that said covenant or restriction is permitted by applicable law, as set forth in the document Recording Date: January 7, 1925 Recording No: Book 559, Page 24, of Deeds Said covenants, conditions and restrictions provide that a violation thereof shall not defeat the lien of any mortgage or deed of trust made in good faith and for value. 4. Any rights of the parties in possession of a portion of, or all of, said Land, which rights are not disclosed by the public records as to rights of tenants only. END OF SCHEDULE B Endorsements: NONE 1927 & 1929 S Hickory St2/12/2025 This map/plat is being furnished as an aid in locating the herein described Land in relation to adjoining streets, natural boundaries and other land, and is not a to survey of the land depicted. Except to the extent a policy of title insurance is expressly modified by endorsement, if any, the Company does not insure dimensions, distances, location of easements, acreage or other matters shown thereon. 1927 & 1929 S Hickory St2/12/2025 STRUCTURAL CALCULATIONS FOR: 1929 S. Hickory St. Santa Ana, CA SCOPE OF WORK: Detached ADU Engineer: Ehab Elias 24752 Via Balboa Laguna Hills CA, 92653 1927 & 1929 S Hickory St2/12/2025 TABLE OF CONTENTS I. DESIGN CRITERIA 3 II. LOADS 4 III. SEISMIC DESIGN 4 IV. GRAVITY DESIGN 7 V. FOUNDATION 5 VI. LATERAL ANALYSIS 6 1927 & 1929 S Hickory St2/12/2025 CODE: 2019 CALIFORNIA BUILDING CODE WITH LOCAL ADDENDA Timber Douglas Fir Larch Rafters & Joints: #2 Grade Beams & Headers: As noted on plans Concrete F c’ = 2,500 PSI @ 28 days Reinforcing Steel ASTM A-615 #4 & Smaller, Grade #5 & Larger, Grade Soil Value 1,500 PSF per Soils IBC Typical Weights: Item PSF R-38 INS 1.5 ½ Gyp Board 2.2 Roofing (Shingles) 3.0 2x4 @ 16” O.C 1.1 2x6 @ 16” O.C 1.7 2x6 @ 24” O.C 2.3 2x8 @ 24” O.C 1.5 ½ Plywood 1.5 Stucco (7/8) 10.0 R-13 0.5 R-19 0.8 2x10 @ 16” O.C. 3.0 2x10 @ 24” O.C. 2.0 2x12 @ 16” O.C. 3.3 2x12 @ 24” O.C. 2.4 14” TJI Joist 4.2 TPO Roofing 0.5 ¾ Plywood 3.0 Rigid Fiberglass (1” thick) 1.5 5/8 Gyp Board 2.8 5/8 Gyp Type X 3.0 2x4 Interior Walls 10.0 1927 & 1929 S Hickory St2/12/2025 3/8” Plywood 1.1 5/8” Plywood 1.8 ¾” Plywood 2.2 Glasss Wool 0.2 Ceramic Tile, ¾” 10.0 Wood Paneling 2.5 Clay Roof Tile 6.5 Hardie Board 2.3 1927 & 1929 S Hickory St2/12/2025 LOADS Wall Loads (Exterior) 2x4 @ 16 1.1 ½ CDX Plywood 1.5 ½ Gyp Board 2.5 R-13 0.5 Siding 10.0 TOTAL 15.6+MISC = 17 DEAD LOAD Roof Loads Asphalt Shingles 3 Framing 2x6 @ 16 O.C. 1.7 Roofing Paper 0.3 ½ Plywood 1.5 TOTAL 6.5 = 7 PSF Dead Load 20 PSF Live Load Ceiling Loads R-38 1.5 Framing 2x6 @ 16 O.C. 1.7 DryWall 2.2 TOTAL 5.4 = 6 PSF Dead Load 10 PSF Live Load 1927 & 1929 S Hickory St2/12/2025 SEISMIC DESIGN 1927 & 1929 S Hickory St2/12/2025 https://seismicmaps.org/ 1927 & 1929 S Hickory St2/12/2025 EXCEL WORK 1927 & 1929 S Hickory St2/12/2025 GRAVITY DESIGN 1927 & 1929 S Hickory St2/12/2025 1927 & 1929 S Hickory St2/12/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Detached ADU Calculation Date/Time:2024-04-12T10:52:25-07:00 (Page 1 of 11) Calculation Description:Addition Input File Name:1929 S Hickory Street.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-04-12   10:52:44 GENERAL INFORMATION 01 Project Name Detached ADU 02 Run Title Addition 03 Project Location 1929 S Hickory Street 04 City Santa Ana,CA 05 Standards Version 2022 06 Zip code 92797 07 Software Version CBECC-Res 2022.3.0 08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)180 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 1 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)724.5 19 Glazing Percentage (%)10.35% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type Natural gas 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 424-P010063878A-000-000-0000000-0000 04/12/2024 13:35 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 1927 & 1929 S Hickory St2/12/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Detached ADU Calculation Date/Time:2024-04-12T10:52:25-07:00 (Page 2 of 11) Calculation Description:Addition Input File Name:1929 S Hickory Street.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-04-12   10:52:44 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 42.9 38.6 54.5 Proposed Design 42.1 38.2 54.2 0.8 0.4 0.3 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 0.00 kWdc 424-P010063878A-000-000-0000000-0000 04/12/2024 13:35 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 1927 & 1929 S Hickory St2/12/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Detached ADU Calculation Date/Time:2024-04-12T10:52:25-07:00 (Page 3 of 11) Calculation Description:Addition Input File Name:1929 S Hickory Street.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-04-12   10:52:44 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.07 0.37 0.24 1.68 -0.17 -1.31 Space Cooling 1.16 26.17 1.22 28.55 -0.06 -2.38 IAQ Ventilation 0.49 5.12 0.23 2.41 0.26 2.71 Water Heating 2.2 23.47 1.92 21.91 0.28 1.56 Self Utilization/Flexibility Credit 0 0 Efficiency Compliance Total 3.92 55.13 3.61 54.55 0.31 0.58 Photovoltaics 0 0 0 0 Battery 0 0 Flexibility Indoor Lighting 0.98 9.16 0.98 9.16 Appl. & Cooking 6.56 43.28 6.55 43.19 Plug Loads 4.99 50.75 4.99 50.75 Outdoor Lighting 0.21 1.83 0.21 1.83 TOTAL COMPLIANCE 16.66 160.15 16.34 159.48 424-P010063878A-000-000-0000000-0000 04/12/2024 13:35 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 1927 & 1929 S Hickory St2/12/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Detached ADU Calculation Date/Time:2024-04-12T10:52:25-07:00 (Page 4 of 11) Calculation Description:Addition Input File Name:1929 S Hickory Street.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-04-12   10:52:44 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 21.45 21.12 0.33 1.54 Net EUI2 21.45 21.12 0.33 1.54 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 0 Standard (14-17%)Fixed none true n/a n/a n/a n/a n/a REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •PV exception 2: No PV required when minimum PV size (Section 150.1(c)14) < 1.8 kWdc (0 kW) •IAQ Ventilation System: as low as 0.15 W/CFM •Insulation below roof deck •Window overhangs and/or fins •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Indoor air quality ventilation •Kitchen range hood 424-P010063878A-000-000-0000000-0000 04/12/2024 13:35 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 1927 & 1929 S Hickory St2/12/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Detached ADU Calculation Date/Time:2024-04-12T10:52:25-07:00 (Page 5 of 11) Calculation Description:Addition Input File Name:1929 S Hickory Street.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-04-12   10:52:44 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Detached ADU 724.5 1 1 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Detached ADU Zone Conditioned HVAC System 1 724.5 9 DHW System 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) N Wall Detached ADU Zone R-15 Exterior Wall 0 Back 283.5 12 90 E Wall Detached ADU Zone R-15 Exterior Wall 90 Right 207 40 90 S Wall Detached ADU Zone R-15 Exterior Wall 180 Front 283.5 43 90 Interior Wall 1 Detached ADU Zone R-0 Interior Wall n/a n/a 207 0 n/a Ceiling (below attic) 1 Detached ADU Zone R-30 Ceiling Rafter n/a n/a 724.5 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Asphalt Shingle Roof Ventilated 4 0.1 0.85 Yes No 424-P010063878A-000-000-0000000-0000 04/12/2024 13:35 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 1927 & 1929 S Hickory St2/12/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Detached ADU Calculation Date/Time:2024-04-12T10:52:25-07:00 (Page 6 of 11) Calculation Description:Addition Input File Name:1929 S Hickory Street.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-04-12   10:52:44 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading W3 Window N Wall Back 0 3 3 1 9 0.3 NFRC 0.23 NFRC Bug Screen W2 Window N Wall Back 0 3 1 1 3 0.3 NFRC 0.23 NFRC Bug Screen W1 Window S Wall Front 180 5 4 1 20 0.3 NFRC 0.23 NFRC Bug Screen W2-2 Window S Wall Front 180 3 1 1 3 0.3 NFRC 0.23 NFRC Bug Screen W1-2 Window E Wall Right 90 5 4 2 40 0.3 NFRC 0.23 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor D1 S Wall 20 0.5 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up W3 1.6 1.6 1.6 1.6 1.6 0 0 0 0 0 0 0 0 W2 1.6 1.6 1.6 1.6 1.6 0 0 0 0 0 0 0 0 W1 1.6 1.6 1.6 1.6 1.6 0 0 0 0 0 0 0 0 W2-2 1.6 1.6 1.6 1.6 1.6 0 0 0 0 0 0 0 0 W1-2 1.6 1.6 1.6 1.6 1.6 0 0 0 0 0 0 0 0 424-P010063878A-000-000-0000000-0000 04/12/2024 13:35 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 1927 & 1929 S Hickory St2/12/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Detached ADU Calculation Date/Time:2024-04-12T10:52:25-07:00 (Page 7 of 11) Calculation Description:Addition Input File Name:1929 S Hickory Street.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-04-12   10:52:44 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab On Grade 1 Detached ADU Zone 724.5 54 none 0 80%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-15 Exterior Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.081 Inside Finish: Gypsum Board Sheathing / Insulation: Wood Siding/sheathing/decking Cavity / Frame: R-15 / 2x4 Sheathing / Insulation: Wood Siding/sheathing/decking Exterior Finish: 3 Coat Stucco R-0 Interior Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.277 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Other Side Finish: Gypsum Board Asphalt Shingle Roof Attic Roofs Wood Framed Ceiling 2x8 @ 16 in. O. C.R-10 None / None 0.086 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-10 / 2x8 Inside Finish: Gypsum Board R-30 Ceiling Rafter Ceilings (below attic) Wood Framed Ceiling 2x8 @ 16 in. O. C.R-30 None / None 0.032 Over Ceiling Joists: R-11.2 insul. Cavity / Frame: R-18.9 / 2x8 Sheathing / Insulation: Wood Siding/sheathing/decking Inside Finish: Gypsum Board 424-P010063878A-000-000-0000000-0000 04/12/2024 13:35 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 1927 & 1929 S Hickory St2/12/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Detached ADU Calculation Date/Time:2024-04-12T10:52:25-07:00 (Page 8 of 11) Calculation Description:Addition Input File Name:1929 S Hickory Street.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-04-12   10:52:44 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW System 1 Domestic Hot Water (DHW)Standard Water Heater 1 1 n/a None n/a Water Heater 1 (1) WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal)NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source Water Heater 1 1 40 Generic Tier3Generic40 TankZone Outside Outside WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW System 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required 424-P010063878A-000-000-0000000-0000 04/12/2024 13:35 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 1927 & 1929 S Hickory St2/12/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Detached ADU Calculation Date/Time:2024-04-12T10:52:25-07:00 (Page 9 of 11) Calculation Description:Addition Input File Name:1929 S Hickory Street.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-04-12   10:52:44 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC System 1 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 HVAC Fan System 1 n/a Setback HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 Ductless MiniSplit HP 1 HSPF2 9.5 18000 10000 EER2SEER2 18 12.48 Not Zonal Single Speed Heat Pump System 1-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan System 1 HVAC Fan 0.45 HVAC Fan System 1-hers-fan 424-P010063878A-000-000-0000000-0000 04/12/2024 13:35 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 1927 & 1929 S Hickory St2/12/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Detached ADU Calculation Date/Time:2024-04-12T10:52:25-07:00 (Page 10 of 11) Calculation Description:Addition Input File Name:1929 S Hickory Street.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-04-12   10:52:44 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan System 1-hers-fan Not Required 0 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam IAQVentRpt 1-1 50 0.15 Exhaust No n/a / n/a No Yes 424-P010063878A-000-000-0000000-0000 04/12/2024 13:35 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 1927 & 1929 S Hickory St2/12/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Detached ADU Calculation Date/Time:2024-04-12T10:52:25-07:00 (Page 11 of 11) Calculation Description:Addition Input File Name:1929 S Hickory Street.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-04-12   10:52:44 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Albert Luu DHL Consultant 04/12/2024 10732 La Batista Ave R22-22 40020 Fountain Valley, CA 92708 (714) 679-6472 Lyndon de Guzman OC-ADU 04/12/2024 24752 Via Balboa Laguna Hills, CA 92653 9494148799 424-P010063878A-000-000-0000000-0000 04/12/2024 13:35 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 1927 & 1929 S Hickory St2/12/2025 1927 & 1929 S Hickory St2/12/2025