Loading...
HomeMy WebLinkAbout1401 S Lowell St - PlanSHEET NUMBER CONSULTANT REVISIONS The above drawings, specifications, ideas, and arrangements represented thereby are and shall remain property of G Design and no part thereof shall be copied, disclosed to others or used in connection with any other project other than the specific project for which they have been prepared and developed, without the written consent of G Design. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and this office must be notified of any variations from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceding with fabrication. 2024 DATE SCALE DRAWN JOB no. GQ A-001 TI T L E S H E E T PATIO COVER 1401 S. LOWELL STREET SANTA ANA, CA 92707 AUG 27, 2024 GIOVANNI QUINTERO 167 OAHU WAY PLACENTIA, CA 92870 TELEPHONE: 310 749.7536 E-MAIL: LOOKING4GIO@GMAIL.COM APRIL 1, 2024 44'-0" 39 ' - 7 " 1 6 ' - 2 1 / 2 " 5' - 0 " 5'-0" 5'-7" (E) ADU W. BORCHARD AVE (N) PATIO COVER PROPERTY LINE 134.79' PROPERTY LINE 134.79' PR O P E R T Y L I N E 6 0 . 8 0 ' PR O P E R T Y L I N E 6 0 . 8 0 ' LO W E L L S T R E E T (E) SINGLE FAMILY RESIDENCE LANDSCAPE LANDSCAPE LANDSCAPE DRIVEWAY 2% S L O P E 2% SLOPE 2% SLOPE 2% SLOPE 2% S L O P E 2% SL O P E 2% SL O P E 2% SL O P E 2% S L O P E PROPOSED SITE PLAN SCALE 1/8" = 1'-0" N PROJECT DIRECTORY OWNER: RAYMOND LUGO 1401 S LOWELL STREET SANTA ANA, CA 92707 DESIGNER: GIOVANNI QUINTERO G DESIGN 167 OAHU WAY PLACENTIA, CA 92870 TEL: 310-749-7536 EMAIL: LOOKING4GIO@GMAIL.COM TITLE 24: EC SERVICES 5702 HERSHOLT AVE LAKEWOOD, CA 90712 TEL: 562-461-3749 SCOPE OF WORK (E) SINGLE FAMILY RESIDENCE -PROPOSED PATIO COVER 549 sqft CODE INFORMATION BUILDING CODES 2022 CALIFORNIA RESIDENTIAL BUILDING CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE CONSTRUCTION TYPE: TYPE VB OCCUPANCY TYPE: R3 / U SPRINKLERS: NO LOT AREA: 8,195 sqft ASS PARCEL NO.: TRACT: BLOCK: ARB: LOT: FLOOR AREA RATIO EXISTING DWELLING (E) SQFT (N) SQFT TOTAL EXISTING ADU 1,630 360 LOT SIZE: 8,195 sqft / FAR: 2,539 = 30% LOT COVERAGE VICINITY MAP PROPOSED PATIO 549 1,630 360 549 Bldg #101120696 APPROVALS: PLNG - P. Raj BLDG - G. Huang PUBLIC WORKS - Y Soto 1401 S Lowell St 11/13/2024 SHEET NUMBER CONSULTANT REVISIONS The above drawings, specifications, ideas, and arrangements represented thereby are and shall remain property of G Design and no part thereof shall be copied, disclosed to others or used in connection with any other project other than the specific project for which they have been prepared and developed, without the written consent of G Design. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and this office must be notified of any variations from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceding with fabrication. 2024 DATE SCALE DRAWN JOB no. GQ A-002 PL A N S A N D E L E V A T I O N S PATIO COVER 1401 S. LOWELL STREET SANTA ANA, CA 92707 AUG 27, 2024 GIOVANNI QUINTERO 167 OAHU WAYPLACENTIA, CA 92870 TELEPHONE: 310 749.7536 E-MAIL: LOOKING4GIO@GMAIL.COM APRIL 1, 2024 16 " 13 ' - 6 1 / 2 " 16 " 10'-10 1/4"10'-10 1/4"10'-10 1/4" 14 ' - 1 0 1 / 2 " 16"9'-6 1/4"16"9'-6 1/4"16"9'-6 1/4"16" 16 ' - 2 1 / 2 " 33'-10 1/2" 6" 33'-10 1/2" 6" 6" 16 ' - 2 1 / 2 " 6" 17 ' - 2 1 / 2 " 34'-10 1/2" (N) PATIO COVER CL CL CL CL CL CL W E N S W E N S 3' - 0 " 4' - 8 " 3' - 1 0 " 11 ' - 6 " 6" 5' - 9 " 7' - 8 " 16" 1" 33'-10 1/2" 10'-10 1/4"10'-10 1/4"10'-10 1/4" 16'-2 1/2" 14'-10 1/2" 3' - 0 " 4' - 8 " 3' - 1 0 " 11 ' - 6 " 5' - 9 1 / 2 " 7' - 8 " 6" CL CL CL CL CL CL 4 12 Cool Weathered Wood Speci!cations 1 See GAF Shingle & Accessory Limited Warranty for complete coverage and restrictions. The word “Lifetime” refers to the length of coverage provided by the GAF Shingle & Accessory Limited Warranty and means as long as the original individual owner(s) of a single-family detached residence [or the second owner(s) in certain circumstances] owns the property where the shingles are installed. For owners/structures not meeting the above criteria, Lifetime coverage is not applicable. 2 This wind speed coverage requires special installation; see GAF Shingle & Accessory Limited Warranty for details. 3 StainGuard® algae protection is available only on shingles sold in packages bearing the StainGuard® logo. Products with StainGuard® algae protection are covered by a 10-year limited warranty against blue-green algae discoloration. See GAF Shingle and Accessory Limited Warranty for complete coverage and restrictions. 4 Energy cost savings are not guaranteed and the amount of savings may vary based on climate zone, utility rates, radiative properties of roofing products, insulation levels, HVAC equipment efficiency, and other factors. 5 Subject to eligibility requirements and loan approval. Terms and conditions apply. See www.renovateamerica.com for more information. NOTE: This product is not available in Canada. • Fiberglass asphalt construction • Lifetime limited transferable warranty1 • Smart Choice® Protection for the !rst 10 years1 • 130 mph limited wind coverage2 • StainGuard® algae protection3 • ENERGY STAR® certi!ed (U.S. only)4 • Can be used to comply with 2016 Title 24, Part 6, Cool Roof Requirements of the California Code of Regulations  • Meets Green Building Standards Code of Los Angeles County for Residential Buildings • Rated by the Cool Roof Rating Council (CRRC) • Texas Department of Insurance listed • Miami-Dade County Product Control approved • State of Florida approved • May be eligible for HERO Program !nancing in California5 Re"ectance & Emittance Data Color Solar Re#ectance Thermal Emittance Solar Re#ectance Index (SRI) Cool Antique Slate 0.28 (Initial) 0.26 (Aged) 0.92 (Initial) 0.91 (Aged) 30 (Initial) 27 (Aged) Cool Barkwood 0.27 (Initial) 0.26 (Aged) 0.90 (Initial) 0.92 (Aged) 28 (Initial) 28 (Aged) Cool Weathered Wood 0.28 (Initial) 0.27 (Aged) 0.92 (Initial) 0.90 (Aged) 30 (Initial) 28 (Aged) CRRC Product ID# 0676-0042a E N E R G Y –S A V I N G S H I N G L E S Timberline® Cool Series® Shingles May Help Reduce Cooling Costs!1 Want to know a cool secret? It used to be that only shingles with white roo!ng granules were considered “cool” by energy-saving standards. But thanks to our proprietary cool granules and unique formulas, Timberline® Cool Series® Shingles have greater re"ectance than our traditional shingles. Our specially designed granules re"ect more light to lower the roof temperature and help reduce the transfer of heat to the space below — to help keep you cooler! Mineral Core Proprietary Outer Coating • Re"ects infrared (invisible) and UV (visible) light to help keep your roof cool Our most re!ective shingle! When the sun’s rays blaze down on your home, your roof absorbs light and heat transfers into your house, which impacts the amount of energy you use for air conditioning. Our Timberline® Cool Series® Shingles are highly re"ective and help reduce the amount of heat transferred into your home to help your home stay cooler during the hot summer months! Timberline® Cool Series® Shingles may also help you save on cooling costs.1 Thanks to the re"ective nature of Timberline® Cool Series® Shingles, part of the heat radiating from the sun gets re"ected, helping to reduce the heat in the attic and heat going into the house. It may translate into savings on air-conditioning bills.1 120˚F 90˚F 90˚F 140˚F 70˚F 70˚F Conventional Roofs Cool Roofs Bene"ts • Helps Reduce Cooling Costs… Cool roofs may help you save on cooling costs1 • Rebates… Some utility companies may provide incentives for using cool shingles • Highest Roo"ng Fire Rating… UL Class A, Listed to ANSI/UL 790 • High Performance… Designed with Advanced Protection® Shingle Technology, which reduces the use of natural resources while providing excellent protection for your home (visit gaf.com/aps to learn more) • StainGuard® Algae Protection... Helps protect the beauty of your roof against unsightly blue-green algae discoloration2 • Stays in Place… Dura Grip™ Adhesive seals each shingle tightly and reduces the risk of shingle blow-off. Shingles warranted to withstand winds up to 130 mph (this wind speed coverage requires special installation; see GAF Shingle & Accessory Limited Warranty for details) • Peace of Mind… Lifetime limited transferable warranty with Smart Choice® Protection (non-prorated material and installation labor coverage) for the !rst ten years3 • Perfect Finishing Touch… Use TimberCrest™ Premium SBS-Modi!ed Ridge Cap Shingles or Seal-A-Ridge® Ridge Cap Shingles4 U.S. only 1 Energy cost savings are not guaranteed and the amount of savings may vary based on climate zone, utility rates, radiative properties of roofing products, insulation levels, HVAC equipment efficiency, and other factors. 2 StainGuard® algae protection is available only on shingles sold in packages bearing the StainGuard® logo. Products with StainGuard® algae protection are covered by a 10-year limited warranty against blue-green algae discoloration. See GAF Shingle and Accessory Limited Warranty for complete coverage and restrictions. 3 See GAF Shingle & Accessory Limited Warranty for complete coverage and restrictions. The word “Lifetime” refers to the length of coverage provided by the GAF Shingle & Accessory Limited Warranty and means as long as the original individual owner(s) of a single-family detached residence [or the second owner(s) in certain circumstances] owns the property where the shingles are installed. For owners/structures not meeting the above criteria, Lifetime coverage is not applicable. 4 These products are not available in all areas. See www.gaf.com/ridgecapavailability for details. 2 PROPOSED ROOF PLAN SCALE 1/4" = 1'-0"N PROPOSED ELEVATIONS SCALE 1/4" = 1'-0" WEST ELEVATION NORTH ELEVATION SOUTH ELEVATION SOUTH ELEVATION ROOF INFORMATIONPROPOSED FLOOR PLAN SCALE 1/4" = 1'-0"N 1401 S Lowell St 11/13/2024 GENERAL NOTES FOR STRUCTURAL OBSERVATION: 1.STRUCTURAL OBSERVATION IS REQUIRED FOR THE STRUCTURAL SYSTEM IN ACCORDANCE WITH THE INFORMATION BULLETIN NO. IB/P/BC 2017-024. STRUCTURAL OBSERVATION IS THE VISUAL OBSERVATION AT THE CONSTRUCTION SITE OF THE ELEMENTS AND CONNECTIONS OF THE STRUCTURAL SYSTEM AT SIGNIFICANT CONSTRUCTION STAGES AND THE COMPLETE STRUCTURE FOR GENERAL CONFORMANCE TO THE APPROVED PLANS AND SPECIFICATIONS. STRUCTURAL OBSERVATION DOES NOT WAIVE THE RESPONSIBILITY FOR THE INSPECTIONS REQUIRED OF THE BUILDING INSPECTOR OR THE DEPUTY INSPECTOR. 2.THE OWNER SHALL EMPLOY A STATE OF CALIFORNIA REGISTERED CIVIL OR STRUCTURAL ENGINEER OR LICENSED ARCHITECT TO PERFORM THE STRUCTURAL OBSERVATION. THE DEPARTMENT OF BUILDING AND SAFETY RECOMMENDS THE USE OF THE ENGINEER OR ARCHITECT RESPONSIBLE FOR THE STRUCTURAL DESIGN WHO ARE INDEPENDENT OF THE CONTRACTOR. 3.THE STRUCTURAL OBSERVER SHALL PROVIDE EVIDENCE OF EMPLOYMENT BY THE OWNER OR THE OWNER'S REPRESENTATIVE. A LETTER FROM THE OWNER, THE OWNER'S REPRESENTATIVE, OR A COPY OF THE AGREEMENT FOR SERVICES SHALL BE SENT TO THE BUILDING INSPECTOR BEFORE THE FIRST SITE VISIT. 4.THE OWNER OR OWNER'S REPRESENTATIVE SHALL COORDINATE AND CALL FOR A MEETING BETWEEN THE ENGINEER OR ARCHITECT RESPONSIBLE FOR THE STRUCTURAL DESIGN, STRUCTURAL OBSERVER, CONTRACTOR, AFFECTED SUBCONTRACTORS AND DEPUTY INSPECTORS. THE PURPOSE OF THE MEETING SHALL BE TO IDENTIFY THE MAJOR STRUCTURAL ELEMENTS AND CONNECTIONS THAT AFFECT THE VERTICAL AND LATERAL LOAD SYSTEMS OF THE STRUCTURE AND TO REVIEW SCHEDULING OF THE REQUIRED OBSERVATIONS. A RECORD OF THE MEETING SHALL BE INCLUDED IN THE FIRST OBSERVATION REPORT SUBMITTED TO THE BUILDING INSPECTOR. 5.THE STRUCTURAL OBSERVER SHALL PERFORM SITE VISITS AT THOSE STEPS IN THE PROGRESS OF THE WORK THAT ALLOW FOR CORRECTION OF DEFICIENCIES WITHOUT SUBSTANTIAL EFFORT OR UNCOVERING OF THE WORK INVOLVED. AT A MINIMUM, THE LISTED SIGNIFICANT CONSTRUCTION STAGES ON THE FOLLOWING STRUCTURAL OBSERVATION/SIGNIFICANT CONSTRUCTION STAGES TABLE REQUIRE A SITE VISIT AND AN OBSERVATION REPORT FROM THE STRUCTURAL OBSERVER. 6.THE STRUCTURAL OBSERVER SHALL PREPARE A REPORT OF THE STRUCTURAL OBSERVATION REPORT FORM IN/FORM.08 (PART 1) FOR EACH SIGNIFICANT STAGE OF CONSTRUCTION OBSERVED. THE ORIGINAL OF THE STRUCTURAL OBSERVATION REPORT SHALL BE SENT TO THE BUILDING INSPECTOR'S OFFICE AND SHALL BE SIGNED AND SEALED (WET STAMP) BY THE RESPONSIBLE STRUCTURAL OBSERVER. ONE COPY OF THE OBSERVATION REPORT SHALL BE ATTACHED TO THE APPROVED PLANS. THE COPY ATTACHED TO THE PLANS SHALL BE SIGNED AND SEALED (WET STAMP) BY THE RESPONSIBLE STRUCTURAL OBSERVER OR THEIR DESIGNEE. COPIES OF THE REPORT SHALL ALSO BE GIVEN TO THE OWNER, CONTRACTOR, AND DEPUTY INSPECTOR. ANY DEFICIENCY NOTED ON THE OBSERVATION REPORT WILL BECOME THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER OF RECORD TO VERIFY ITS COMPLETION BY HIM (HER), OR BY A REGISTERED DEPUTY INSPECTOR AT THE DISCRETION OF THE STRUCTURAL OBSERVER. 7.A FINAL OBSERVATION REPORT AND THAT OF THE REGISTERED DEPUTY INSPECTOR MUST BE SUBMITTED WHICH SHOWS THAT ALL OBSERVED DEFICIENCIES WERE RESOLVED AND STRUCTURAL SYSTEM GENERALLY CONFORMS WITH THE APPROVED PLANS AND SPECIFICATIONS. THE DEPARTMENT OF BUILDING AND SAFETY WILL NOT ACCEPT THE STRUCTURAL WORK WITHOUT THIS FINAL OBSERVATION REPORT AND THAT OF THE REGISTERED DEPUTY INSPECTOR (WHEN PROVIDED) AND THE CORRECTION OF SPECIFIC DEFICIENCIES NOTED DURING NORMAL BUILDING INSPECTION. 8.THE STRUCTURAL OBSERVER SHALL PROVIDE THE ORIGINAL STAMPED AND SIGNED STRUCTURAL THE COUNTY OF LOS ANGELES OBSERVATION REPORT TO INSPECTOR. 9.WHEN THE OWNER ELECTS TO CHANGE THE STRUCTURAL OBSERVER OF RECORD, THE OWNER SHALL: A) NOTIFY THE BUILDING INSPECTOR IN WRITING BEFORE THE NEXT INSPECTION BY SUBMITTING COMPLETED "STRUCTURAL OBSERVATION PROGRAM AND DESIGNATION OF THE STRUCTURAL OBSERVER" FORM IN/FORM.08 (PART 2) B) CALL AN ADDITIONAL PRECONSTRUCTION MEETING. C) FURNISH THE REPLACEMENT STRUCTURAL OBSERVER WITH A COPY OF ALL PREVIOUS OBSERVATION REPORTS. THE REPLACEMENT STRUCTURAL OBSERVER SHALL APPROVE THE CORRECTION OF THE ORIGINAL OBSERVED DEFICIENCIES UNLESS OTHERWISE APPROVED BY PLAN CHECK SUPERVISION. THE POLICY OF THE DEPARTMENT SHALL BE TO CORRECT ANY PROPERTY NOTED DEFICIENCIES WITHOUT CONSIDERATION OF THEIR SOURCE. 10. THE ENGINEER OR ARCHITECT OF RECORD SHALL DEVELOP ALL CHANGES RELATING TO THE STRUCTURAL SYSTEMS. THE BUILDING DEPARTMENT SHALL REVIEW AND APPROVE ALL CHANGES T6 THE APPROVED PLANS AND SPECIFICATIONS. SHEET NUMBER CONSULTANT The above drawings, specifications, ideas, and arrangements represented thereby are and shall remain property of GxG CO-op Design and no part thereof shall be copied, disclosed to others or used in connection with any other project other than the specific project for which they have been prepared and developed, without the written consent of GxG CO-op Design. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and this office must be notified of any variations from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceding with fabrication.2021 DATE SCALE DRAWN JOB no. REVISIONS INDICATED FEB. 29, 2024 13637 RUTHER AVE. UNIT R SOUTH GATE, CA 90280 TELEPHONE: 310 749.7536 E-MAIL: LOOKING4GIO@GMAIL.COM GIOVANNI QUINTERO 1401 S. Lowell Street, Santa Ana, CA 92707 NEW PATIO COVER GENERAL NOTES AND SPECIFICATIONS WOOD 1- WOOD FRAMING GENERAL PROVIDE DOUBLE JOISTS UNDER AND PARALLEL TO ALL BEARINGS PARTITIONS. ALL BOLT HOLES SHALL DE DRILLED 1/32" TO 1/16" OVERSIZED. 2x12 JOISTS SHALL BE BLOCKED AT THE SUPPORTS AND AT 8 FEET o.c. (AND RAFTERS GREATER THAN 10" DEPTHS AT THE SUPPORTS AND AT 10 FEET O.C.) WITH SOLID 2x BLOCKING 2" SHALLOWER THAN JOISTS OR APPROVED METAL CROSS BRIDGING. WOOD FRAMING MEMBERS: DOUGLAS FIR-LARCH N°2 UNLESS OTHERWISE MARKED ON THE PLANS. RAFTER TIES SPACED AT 4 FEET (MAX.) ON CENTER ARE REQUIRED IMMEDIATELY ABOVE CEILING JOISTS WHICH ARE NOT PARALLEL TO THE RAFTERS. NAILING SCHEDULE CONNECTION FASTENING LOCATION JOIST TO SILL OR GIRDER 3-8d TOENAIL BRIDGING TO JOIST 2-10d TOENAIL EACH END 1"x6" SUBFLOOR OR LESS TO EA. JOIST 2-8d FACE NAIL WIDER THAN 1"x8" SHEATHINGS TO EACH BEARING 3-8d FACE NAIL 2" SUBFLOOR TO JOIST OR GIRDER 2-16d BLIND AND FACE NAIL SOLE PLATE TO JOIST OR BLOCKING 16d @16" O.C.TYP. FACE NAIL SOLE PLATE TO JOIST OR BLOCKING 2-16d @16" O.C.BRACED WALL PANELS TOP PLATE TO STUD 2-16d END NAIL STUD TO SOLE PLATE 4-8d TOE NAIL 2-16d END NAIL DOUBLE STUDS 16d @24" O.C.FACE NAIL DOUBLE TOP PLATES 16d @16" O.C.TYP. FACE NAIL DOUBLE TOP PLATES 8-16d LAP SPLICE BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE 3-8d TOE NAIL RIM JOIST TO TOP PLATE 8d @6" O.C.TOE NAIL TOP PLATES, LAPS AND INTERSECTIONS 2-16d FACE NAIL CONTINUOUS HEADER, TWO PIECES 16d @16" O.C.EACH EDGE CEILING JOISTS TO PLATE 3-8d TOE NAIL CONTINUOUS HEADER TO STUD 4-8d TOE NAIL CEILING JOISTS, LAPS OVER PARTITIONS 3-16d FACE NAIL CEILING JOISTS TO PARALLEL RAFTERS 3-16d FACE NAIL RAFTER TO PLATE 3-10d TOE NAIL 1"x BRACE TO EACH STUD AND PLATE 2-8d FACE NAIL 1"x6" SHEATHING OR LESS TO EACH BEARING 2-8d FACE NAIL WIDER THAN 1"x8" SHEATHINGS TO EACH BEARING 3-8d FACE NAIL BUILT IT-UP CORNER STUDS 16d @24" O.C. BUILT-UP GIRDER & BEAMS 20d @32" O.C.FACE NAIL TOP & BOTTOM STAGGERED 2-20d ENDS 2"x PLANKS 2-16d EACH BEARING WOOD SHEAR AND DIAPHRAGMS COMMON NAILS SHALL BE USED FOR ALL DIAPHRAGMS AND SHEAR WALL NAILING. ROOF SHEATHING: 1/2" 5/8" THICK PLYWOOD CDX WITH INDEX 32/16. 8d 10d NAILS @ 6" o.c. AT PANELS EDGES, AND 8d NAILS @ 12" o.c. AT PANEL FIELD. ALLOW 1/8" SPACING AT PANEL EDGES, UNLESS OTHERWISE RECOMMENDED BY THE PANEL MANUFACTURER. PLYWOOD DIAPHRAGMS: PRODUCT STANDARD PS 1-19, DOUGLAS FIR-LARCH. WATERPROOFING: STUCCO OVER PLYWOOD SHEAR WALL WILL BE WATERPROOFED WITH A MINIMUM OF TWO 15# (GRADE D) UNDERLAYMENTS. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANELS EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.8.(1) ON IBC 2021. WOOD CONSTRUCTION 1.STRUCTURAL LUMBER SHALL BE GRADE-MARKED DOUGLAS FIR-LARCH: RAFTER 2 TO 4 WIDE UP TO 6 DEEP Nº2 2 TO 4 WIDE, 8 OR LARGER Nº2 JOISTS 2 TO 4 WIDE, 6 AND DEEPER Nº2 BEAMS, PURLINS OVER 4 WIDE Nº1 SUB-PURLINS 2 TO 4 WIDE, 4 DEEP Nº1 LEDGERS Nº2 STUDS 2x4 OR 3x4 Nº2 STUDS 2x6 Nº2 POSTS Nº2 SILLS, PLATES AND BLOCKINGS Nº2 2.SILLS OR PLATES BEARING ON CONCRETE OR MASONRY WHICH IS WITHIN 48" OF EARTH SHALL BE PRESSURE TREATED, OR EQUAL, WOOD SILL PLATES SHALL BE BOLTED TO THE FOUNDATION WITH 5/8" DIAMETER x 10" BOLTS 4'-0" o.c. 12" MIN. FROM ENDS, OR 2 BOLTS MIN. PER PIECE. WHERE DIFFERENT SIZES AND/OR SPACING ARE REQUIRED, THEY SHALL GOVERN. INSTALL WITH 3"x3"x1/4" (OR 2"x2"x3/16") PLATE WASHER AT EACH ANCHOR BOLT. 3.PARALLAM/GLUE LAM BEAMS MUST BE FABRICATED IN A LADBS LICENSED SHOP. 4.JOISTS SHALL BE BLOCKED AT SUPPORTS AND BRIDGED OR BLOCKED AT INTERVALS OF 8 FT WHERE JOISTS ARE 2x12 OR DEEPER. 5.JOISTS UNDER NON-BEARING PARTITIONS SHALL BE DOUBLED, EXCEPT AS NOTED. 6.LAGBOLTS (& SCREWS) SHALL BE PRE-DRILLED TO SHANK DIAMETER AND FULL DEPTH AND SCREWED (NOT DRIVEN) INTO PLACE. 7.CUT WASHERS SHALL BE PLACED UNDER HEADS AND NUTS OF ALL BOLTS AND UNDER HEADS OF LAGBOLTS. ONE CUT WASHER SHALL BE USED FOR BOLTS CONNECTING WOOD LEDGERS TO CONCRETE OR MASONRY WALLS. 8.ALL HARDWARE USED FOR WOOD CONNECTION SHALL BE SIMPSON STRONG-TIE PRODUCTS. INSTALL PER MANUFACTURERS RECOMMENDATIONS. ALTERNATE PRODUCTS WILL ONLY BE PERMITTED IF WRITTEN APPROVAL AND ACCEPTANCE IS OBTAINED BY ENGINEER. 9.ALL LUMBER SHALL HAVE A MOISTURE CONTENT NOT TO EXCEED 19% AT THE TIME OF FABRICATION OR CONSTRUCTION. 10.PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIA. AND FULL DIA. FOR SMOOTH SHANK PORTION. 11.PLACE 2" FIREBLOCKING IN STUD WALLS AT CEILING AND FLOOR LEVELS, AT EACH 10" HEIGHT OF STUDS, AND BETWEEN STAIR STRINGERS AT SUPPORTS. 12.ALL DIAPHRAGMS AND SHEAR NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 13.ALL PARALLEL STRAND LUMBER (PSL)SHALL BE 2.0E, 2900Fb BYTRUS JOIST MACMILLAN. PARAMETERS DESIGN, CBC 2022, LABC 2023 WIND DESIGN 1.BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR = 96 2.WIND IMPORTANCE FACTOR, I=1.0 AND OCCUPANCY CATEGORY = II 3.WIND EXPOSURE CATEGORY: B (CASE 1) 4.THE APPLICABLE INTERNAL PRESSURE COEFFICIENT =0.18 SEISMIC DESIGN 1.SEISMIC IMPORTANCE FACTOR, I=1.0 , AND OCCUPANCY CATEGORY = II 2.MAPPED SPECTRAL RESPONSE ACCELERATIONS, Ss=128.90%g AND S1=46.10%g 3.SITE CLASS = D 4.SPECTRAL RESPONSE COEFFICIENTS, SDS=1.031g AND SD1=0.400g 5.SEISMIC DESIGN CATEGORY=D 6.BASIC SEISMIC-FORCE-RESISTING SYSTEM(S)= WOOD POST SYSTEM 7.DESIGN BASE SHEAR = 5153 LBS 8.TOTAL BUILDING WEIGHT = 8238 LBS 9.SEISMIC RESPONSE COEFFICIENT(S), Cs=0.69 10.RESPONSE MODIFICATION FACTOR(s), R =1.5 11.ANALYSIS PROCEDURE USED = EQUIVALENT LATERAL FORCE PROCEDURE 12.REDUNDANCY FACTOR USED = 1.3 BASIS OF DESIGN ROOF DEAD LOAD = 9.00 PSF CEILING DEAD LOAD = 7.00 PSF ROOF LIVE LOAD = 20.00 PSF CEILING LIVE LOAD = 10.00 PSF CONCRETE & REINFORCING STEEL NOTES CONCRETE FOUNDATION, FLOOR SLABS. ALL CONCRETE SHALL ATTAIN THE FOLLOWING MINIMUM STRENGTHS AT 28 DAYS: FOOTINGS AND SLAB-ON-GRADE = 2500 PSI. BAR SPLICES IN CONCRETE SHALL BE LAP 40 BAR DIAMETERS MINIMUM, AND MAY BE WIRED TOGETHER, UNLESS OTHERWISE NOTED ON PLANS. REINFORCING STEEL REINFORCING BARS SHALL CONFORM TO THE FOLLOWING ASTM RATING AND GRADE TYPE FOR BAR SIZES LISTED: #4 AND SMALLER ASTM A 615 GRADE 40 (MIN) #5 AND LARGER ASTM A 615 GRADE 60 ADDITIONAL NOTES 1)CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/COMPONENT LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE LADBS INSPECTORS AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT PER SEC. 1709.1. 2)CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING, CONCRETE STRENGTH f'c>2500 PSI, HIGH STRENGTH BOLTING, SPRAYED-ON FIREPROOFING, ENGINEERED MASONRY, HIGH-LIFT GROUTING, PRE-STRESSED CONCRETE, HIGH LOAD DIAPHRAGMS AND SPECIAL MOMENT-RESISTING CONCRETE FRAMES. 3)IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION REPORT MAY BE REQUIRED. 4)PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS, AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING, AND OTHER FASTENING COMPONENTS OF THE SEISMIC FORCE RESISTING SYSTEM. SPECIAL INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED WHERE THE FASTENER SPACING OF THE SHEATHING IS 4 INCHES ON CENTER OR LESS. 5)FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. 6)BEAMS MUST BE FABRICATED IN A LADBS LICENSED SHOP. IDENTIFY GRADE SYMBOL AND LAMINATION SPECIES PER T 5-A, 2005 NDS SUPP. 7)PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIA. AND FULL DIA. FOR SMOOTH SHANK PORTION. 8)A COPY OF THE LOS ANGELES RESEARCH REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE. 9)ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.8.(1) ON IBC 2021. 10)ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 11)ALL BOLT HOLES SHALL BE DRILLED 132" TO 116" OVERSIZED. NEW PATIO COVER PROJECT ADDRESS: Description of Work: Owner:Architect:Engineer: PERMIT APPL. NO.: STRUCTURAL OBSERVATION (ONLY CHECKED ITEMS ARE REQUIRED) Firm or Individual to be responsible for the Structural Observation: Name: FOUNDATION WALL FRAME DIAPHRAGM Concrete Masonry Wood Others: Footing, Stem Walls, Piers Mat Foundation Caisson, Piles, Grade Beams Stepp'g/Retain'g Foundation, Hillside Special Anchors Others: Concrete Steel Deck Wood Others: Steel Moment Frame Steel Braced Frame Concrete Moment Frame Masonry Wall Frame Others: HFX DECLARATION BY OWNER I, the Owner of the project, declare that the above listed firm or individual is hired by me to be the Structural Observer. Signature Date Phone:Calif. Registration: NOTE: STRUCTURAL ENGINEER SHALL BE NOTIFIED OF ANY SITE MEETING OR STRUCTURAL OBSERVATION AT LEAST 48 HRS IN ADVANCE OF APPOINTMENT DATE. 1401 Lowell St., Santa Ana, CA 92707 STRUCTURAL OBSERVATION PROGRAM AND DESIGNATION OF THE STRUCTURAL OBSERVER SOIL INFORMATION DEFAULT EARTH MATERIAL PARAMETERS FOUNDATION BEARING PRESSURE 1500 PSF COEFFICIENT OF FRICTION (1)0.25 PASSIVE EARTH PRESSURE (EFP)100 PCF MAXIMUM PASSIVE EARTH PRESSURE 1500 PSF CONVENTIONAL CONTINUOUS FOOTING DESIGN MINIMUM FOUNDATION DEPTH 24 IN. INDEPENDENT (PAD) FOOTING DESIGN MINIMUM EMBEDMENT DEPTH INTO BEARING MATERIAL 24 IN. NOTE: (1) WHEN COMBINING FRICTIONAL RESISTANCE AND PASSIVE PRESSURE, THE PASSIVE PRESSURE COMPONENT SHALL BE REDUCED BY ONE-THIRD. SPECIAL INSPECTIONS TABLE INSPECTION TASK FREQUENCY OF INSPECTION CONTINUOUS DURING TASK LISTED *PERIODICALLY DURING TASK LISTED REINFORCING STEEL A- FORMWORK FOR SHAPE, LOCATION 6 DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED -X B- VERIFY FOUNDATION EXCAVATIONS ARE EXTENDED TO PROPER DEPTH -X * PERIODIC SPECIAL INSPECTION: PART-TIME OBSERVATION OF WORK BY A DEPUTY INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK HAS BEEN OR IS BEING PERFORMED AND AT THE COMPLETION OF WORK. SHEET INDEX S-1.1 GENERAL NOTES & SPECIAL INSPECTIONS S-2.1 STRUCTURAL PLANS S-3.1 FRAMING & FOUNDATION DETAILS S-4.1 TYP. FRAMING DETAILS S-1.1 GE N E R A L N O T E S & SP E C I A L I N S P E C T I O N U HANGER ESR-2552 FRAMING CLIPS ESR-3096 SHOT PINS ESR-1799 CC COLUMN CAP ESR-2604 STRAP ESR-2105 RESEARCH REPORT- ICC-ES# Wood Knee Brace 1401 S Lowell St 11/13/2024 SCALE: 1/4" = 1'-0" FOUNDATION PLAN 1 2 3 4 A B CONC. SLAB ON GRADE SEE NOTE #7 [F1] 2'-3"SQ.x24''D w/ (4) #5 E.W AT BOTTOM [F1] 2'-3"SQ.x24''D w/ (4) #5 E.W AT BOTTOM [F1] 2'-3"SQ.x24''D w/ (4) #5 E.W AT BOTTOM [F1] 2'-3"SQ.x24''D w/ (4) #5 E.W AT BOTTOM 5 S3.1 TYP.5 S3.1 TYP. 5 S3.1 TYP.5 S3.1 TYP. 13 S3.1TYP. 13 S3.1TYP. 13 S3.1TYP.13 S3.1 TYP. FOUNDATION NOTES 1.ALL POSTS SHALL BE CONNECTED TO SILL PLATE WITH "A35" AT EA. SIDE TYP. UNLESS HARDWARE IS NOTED ON PLAN. 2.ALL FOOTING SHALL HAVE F'c = 2500 PSI UNLESS NOTED OTHERWISE. 3.ALL BOLT HOLES SHALL BE DRILLED A MAXIMUM OF 1/16" OVERSIZED. INSPECTOR TO VERIFY. 4.FOUNDATION SILL SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. FIELD-CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE-TREATED WOOD SHALL BE FIELD-TREATED PER AWPA M4. 5.CONTRACTOR TO VERIFY ALL DIMENSIONS & ELEVATIONS WITH ARCHITECTURAL PLANS PRIOR TO STARTING ANY WORK. 6.FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT TREATED WOOD SHALL BE OF HOT ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL.. 7.CONCRETE SLAB ON GRADE SHALL BE 4" THICK w/ #4 @ 16" O.C. E.W. OVER 2" SAND OVER 10MIL VAPOR OVER 2" SAND OR GRAVEL BASE. INDICATES (N) CONCRETE PAD INDICATES (N) SLAB ON GRADE. SEE NOTE #7 SCALE: 1/4" = 1'-0" ROOF FRAMING PLAN CONT. 4x12 RBM 2x 8 R . R . @ 1 6 ' ' O . C . 6x10 DBM 101 6x 1 0 D B M 1 0 2 6x 1 0 # 1 D B M 1 0 3 6x 1 0 D B M 1 0 2 2x 1 0 C . J . @ 1 6 ' ' O . C . 2x 8 R . R . @ 1 6 ' ' O . C . 1 2 3 4 A B 6x10 DBM 101 6x10 DBM 101 6x10 DBM 101 6x10 DBM 101 6x10 DBM 101 6x 1 0 # 1 D B M 1 0 3 11'-1"10'-10"11'-1" 33'-0" 15 ' - 4 " 1 S3.1 1 S3.1 1 S3.1 1 S3.1 1 S3.1 1 S3.1 7 S3.1 2 S3.1 2 S3.1 7 S3.1 6 S3.1 8 S3.1 8 S3.1 3 S3.1 4 S3.1 3 S3.1 3 S3.1 4 S3.1 4 S3.1 4 S3.1 3 S3.1 K.P.K.P.K.P.K.P. ROOF FRAMING NOTES 1.ROOF SHEATHING SHALL BE 1/2" PLYWOOD, CD-X P11 32/16, w/ 8d COMMON NAILS @ 6", 12" O.C. 2.ALL POSTS ARE 6 x 6 MINIMUM U.N.O. 3.ALL POSTS SHALL BE CONNECTED TO SILL PLATE WITH "A35" AT EA. SIDE TYP. UNLESS HARDWARE IS NOTED ON PLAN. 4.ALL EXT. WALLS, SHEAR WALLS & BEARING WALLS EXCEEDING 10'-0" AND LESS THAN 15'-0" HEIGHT SHALL BE 2x6 OR 3x4 @ 16" O.C. 5.ALL WOOD FRAMING MEMBERS U.N.O. SHALL BE: 2x MEMBER DF #2 OR BETTER 4x MEMBER DF #2 OR BETTER 2x STUDS DF #2 OR BETTER 6.ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 7.FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT TREATED WOOD SHALL BE OF HOT ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. 8.ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.8.(1) ON IBC 2021. 3 S4.1 K.P. A INDICATES SHEAR WALL TYPE, SEE SCHEDULE INDICATES GRID LINE INDICATES KING POST ABOVE INDICATES POST BELOW LEGEND ROOF RAFTERS (R.R.) - SIZE AND SPACING PER PLAN CEILING JOIST (C.J.) - SIZE AND SPACING PER PLAN DBM RBM DENOTES DROPPED BEAM BELOW FLOOR/ROOF JOISTS. DENOTES RIDGE BEAM ABBREVIATIONS SHEET NUMBER CONSULTANT The above drawings, specifications, ideas, and arrangements represented thereby are and shall remain property of GxG CO-op Design and no part thereof shall be copied, disclosed to others or used in connection with any other project other than the specific project for which they have been prepared and developed, without the written consent of GxG CO-op Design. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and this office must be notified of any variations from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceding with fabrication.2021 DATE SCALE DRAWN JOB no. REVISIONS INDICATED FEB. 29, 2024 13637 RUTHER AVE. UNIT R SOUTH GATE, CA 90280 TELEPHONE: 310 749.7536 E-MAIL: LOOKING4GIO@GMAIL.COM GIOVANNI QUINTERO 1401 S. Lowell Street, Santa Ana, CA 92707 NEW PATIO COVER S-2.1 ST R U C T U R A L P L A N S 1401 S Lowell St 11/13/2024 S-3.1 FR A M I N G & F O U N D A T I O N DE T A I L S SHEET NUMBER CONSULTANT The above drawings, specifications, ideas, and arrangements represented thereby are and shall remain property of GxG CO-op Design and no part thereof shall be copied, disclosed to others or used in connection with any other project other than the specific project for which they have been prepared and developed, without the written consent of GxG CO-op Design. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and this office must be notified of any variations from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceding with fabrication.2021 DATE SCALE DRAWN JOB no. REVISIONS INDICATED FEB. 29, 2024 13637 RUTHER AVE. UNIT R SOUTH GATE, CA 90280 TELEPHONE: 310 749.7536 E-MAIL: LOOKING4GIO@GMAIL.COM GIOVANNI QUINTERO 1401 S. Lowell Street, Santa Ana, CA 92707 NEW PATIO COVER RAFTER TO BEAM CONN.1 BEAM PER PLAN CEILING JOISTS PER PLAN S ROOF RAFTER PER PLAN 7- 16d ROOF SHT'G PER PLAN BEAM PER PLAN 6x6 DIAGONAL BRACING W/ (4) 5/8"∅ x 4" LONG LAG SCREWS BEAM PER PLAN POST PER PLAN 3' - 0 " 4" 2.5" MIN 45° 2.5"MIN . 2. 5 ' ' MI N . RIDGE BEAM TO K.P. CONN.2 KING POST PER PLAN B.N.B.N. SIMSON "CCQ" POST CAP INVERTED SIMPSON "CCQ" POST CAP BEAM PER PLAN ROOF SHT'G PER PLAN ROOF RAFTER PER PLAN RIDGE BEAM PER PLAN"MSTA36" STRAP FULLY NAILED w/ 10d NAILS KNEE BRACE END CONN.3 A SECTION A-A (1) 3 4" DIA. BOLT 2. 5 " MI N . (1) 3 4" DIA. BOLT 6x6 DIAGONAL BRACING W/ (4) 5/8"∅ x 4" LONG LAG SCREWS 6x6 DIAGONAL BRACING BEAM PER PLAN (1) 3 4" DIA. BOLT 2.5" MIN 2.5' 'MIN . SIMPSON "CCTQ" COLUMN CAP 2x SHAPED BLK'G W/ "A35" @ 16'' O.C. B.N. SIMPSON 'H2.5A' TIE ON EACH RAFTER 6x6 DIAGONAL BRACING 2' - 6 " 2. 5 " MI N . 2.5" MIN A B 11 4"3"11 4" 212" 3" SECTION A-A SECTION B-B 3" 23 4"23 4" 11 4"3"11 4" 212" 3" KNEE-BRACE CENTER CONN.4 POST PER PLAN RAFTER TO BEAM CONN.8NOT USED12NOT USED16 NOT USED11NOT USED15 EXT. PAD FOOTING DETAIL5 NOT USED14 TYP. CONCRETE SLAB DETAIL13 6"6" 25"LAP TYP. 12 " 1'-6" DE P R E S S I O N S E E AR C H T . P L A N 1'-0" 112" 18" 12 " M I N . 8" MIN. NOTE: WEAKENED PLANE JOINTS (CONSTRUCTION OR CONTROL JOINTS) SHALL BE PROVIDED AT 10'-0" EA. WAY (MAX.). CONSTRUCTION JOINT SHALL BE PROVIDED AT END OF EA. POUR. 2-#4 EA. SIDE CONCRETE SLAB AND BASE PER FOUNDATION PLAN #4 CONT. CONCRETE SLAB AND BASE PER FOUNDATION PLAN CONCRETE SLAB AND BASE PER FOUNDATION PLAN SAWCUT WITHIN 24 HOURS OF POUR CONCRETE SLAB AND BASE PER FOUNDATION PLAN 4# CONT. TOP & BOTT. FINISH GRADE CONSTRUCTION JOINT DEPRESSION CONTROL JOINT SLAB EDGE LEAVE ROUGH SURFACE AFTER FIRST POUR CLEAN & WATER BEFORE SECOND POUR A B C D RIDGE BEAM CONNECTION6 SIMPSON "ECCLQ" COLUMN CAP B.N.B.N. ROOF SHT'G PER PLAN ROOF RAFTER PER PLAN "MSTA36" STRAP FULLY NAILED w/ 10d NAILS RIDGE BEAM PER PLAN "U" HANGER SLOPED "U" HANGER SLOPED ROOF RAFTER PER PLAN ROOF SHT'G PER PLAN PER PLAN 3" C L R PE R P L A N 8" M I N . POST PER PLAN SIMPSON CBSQ-SDS2CONCRETE PAD REINF. PER SCHEDULE CONCRETE SLAB PER PLAN #4 DOWELS @ 16'' O.C. BENT 20'' INTO SLAB & 20'' INTO FOOTING 8"MIN. FINISH GRADE EQ.EQ 2' - 3 " RIDGE BEAM TO BEAM CONN.7 ROOF SHT'G PER PLAN ROOF RAFTER PER PLAN KING POST PER PLAN BEAM PER PLAN STUD WALL PER PLAN B.N.B.N. RIDGE BEAM PER PLAN "MSTA36" STRAP FULLY NAILED w/ 10d NAILS "A35" @ 16" O.C. SIMPSON "CCQ" POST CAP SIMPSON "HL" W/ (2) 1/2" DIA. LAG SCREWS w/ 4'' EMBED. 1/2" DIA. THRU BOLTS E.N. B.N. ROOF SHEATHING PER PLAN ROOF RAFTER PER PLAN 2x6 STUDS @ 16'' O.C. DBL.2x TOP PLATES 2x RIM JOIST W/ SIMPSON "A35" @ 16'' O.C. CEILING JOISTS PER PLAN CEILING JOISTS PER PLAN w/(2) 10d NAILS @ 16 O.C. 2x4 LOCKOUT NOTCH AS REQUIRED @ 24" O.C. (3 BAYS) 2x BLK'G @ 48" O.C. (2 BAYS) 12'' PLY. w/ 10d E.N. @ 8'' O.C. & 10d F.N. @ 12'' O.C. 2x SILL W/ 20d NAILING @ 6'' O.C. E.N. BEAM PER PLAN 4-10d NAILS TO BLOCKING ROOF 2x FASCIA NOT USED10 2x FASCIA 1401 S Lowell St 11/13/2024 SHEATHING NAILING3 TYP. STUD WALL BORING & NOTCHING4 TYPICAL SHEARWALL NAILING10TYPICAL PLATE SPLICE14 TYPICAL DETAILS16 NOTE : 1.SPLICE SHOULD NOT BE WITHIN SHEAR WALL PANELS WITH EDGE NAILING CLOSER THAN 6" O.C. OR DOUBLE SIDED SHEAR WALLS. 2.SPLICE ALSO SHOULD NOT BE WITHIN THE LENGTH OF ANY STEEL STRAPS CONNECTION. 3.WHEN SPLICE OF TOP PLATES CAN NOT BE RELOCATED OUTSIDE THE AFOREMENTIONED SHEAR PANEL OR STRAP CONNECTION, OR WHERE REQUIRED PER PLAN, USE ALT. BOLTING CONNECTION "B". STUDS PER PLAN DOUBLE 2x TOP PLATE 4'-0 SPLICE W/ 16d @ 3" O.C. STAGG (TYP.) U.N.O. SPLICE LENGTH 312"MIN.2"MIN.312"MIN.USE (4) 12" BOLTS MIN. OR AS SPECIFIED ON PLAN A - TYPICAL NAILING CONNECTION AT SPLICE B - ALTERNATIVE BOLTING CONNECTION AT SPLICE STUDS PER PLAN DOUBLE 2x TOP PLATE JOISTS/RAFTER SHEATHING PANEL 2x BLOCKING AT EXTERIOR WALL FIELD NAILING (F.N.) AT JOISTS / RAFTER BOUNDARY NAILING (B.N.) AT EXTERIOR WALL EDGE NAILING (E.N.) AT JOISTS/RAFTERS WHERE PANELS ABUT. DOUBLE TOP PLATES 2x BLOCKING AT PANEL EDGES 15/32" STRUCTURAL PANEL WALL STUDS FIELD NAILING (F.N.) SILL PLATE EDGE NAILING (E.N.) EDGE NAILING (E.N.) EDGE NAILING (E.N.) AT ALL PANEL EDGES ROOF / FLOOR SHEATHING WALL SHEATHING NOTES: 1.NAILS SHALL BE PLACED 3/8" FROM PANEL EDGES. 2.PROVIDE 1/8" GAP BETWEEN SHEATHING PANEL. 3.MINIMUM DIMENSION OF SHEATHING PANEL IN ANY DIRECTION SHALL BE 2'-0" 4.WALL SHEATHING PANEL MAY BE INSTALLED WITH THE LONG DIRECTION ORIENTED VERTICALLY. EXTERIOR & BEARING PARTITION NOTE: -BORING AND NOTCHING SHALL NOT OCCUR IN SAME STUDS NOTCH/BORE % OF STUD 2x4 STUD 2x6 STUD 25%7 8"1 3 8" 40%1 7 16"2 316" 60%2 116"3 5 16" WIDTH=D WIDTH=D 60 % D NOTCH IN STUD 40% D (MAX) 60% D (MAX) BORED HOLE 5 8" MIN. NON-BEARING PARTITION NOTCH IN STUD BORED HOLE 60 % D 5 8" MIN. 40% D (MAX) 25% D (MAX) E.N. (TYP.) PER S.W. SCHED. E.N.(TYP.) PER S.W. SCHED.OPENING PER PLAN (2)2x PL. MSTA36 VA R I E S E.N.(TYP.) PER S.W. SCHED. (2) 2x BLK'G F.N.(TYP.) @12" O.C. ~ 24" MIN. E.N.(TYP.) PER E.O.S.W. SCHED. 2x BLK'G (TYP.) E.N. (TYP.) PER S.W. SCHED. 2x BLK'G (TYP.) F.N.(TYP.) @ 12" O.C. STUD PER PLAN E.N.(TYP.) PER S.W. SCHED. PLTWD. SHT'G PER S.W. SCHED. ~ PLYWD. SHT'G PER S.W. SCHED. SILL ATTACHMENT PER S.W. SCHED. 2x STUD @ 16" O.C. 2x4 DBL. TOP PLATE 2x4 OR 3x4 SILL PLATE (SIM.) 2x6 DBL. TOP PLATE 2x6 OR 3x6 SILL PLATE (SIM.) 2x8 DBL. TOP PLATE 2x8 OR 3x8 SILL PLATE (SIM.) NOTE: -BOTH TOP & BOTTOM SURFACES NOT TO BE NOTCHED WITHIN SAME 1/3 OF SPAN -MIN. DISTANCE BETWEEN HOLES WITHIN SAME 1/3 OF SPAN SHALL BE TWICE THE DIAMETER OF HOLES -L = NOTCH LENGTH NOT TO BE GREATER THAN 1/3 OF THE MEMBER'S DEPTH NOTCH & HOLES PERMITTED 12" MI N . 312" MAX.12"MIN.12"MIN. 112"M I N . 2" MA X . 512" MAX.12"MIN.12"MIN. 212"M I N . 3" MA X . 512" MAX.12"MIN.12"MIN. 312"M I N . 1 1/4"x16 GA. STRAP W/ 6-10d COMM. NAILS EA. END @EA. PLATE (STRAP NOT REQ'D FOR SILL PLATE) 1 1/4" x 16 GA. STRAP W/ 8-10d COMM. NAILS EA. END @EA. PLATE (STRAP NOT REQ'D FOR SILL PLATE) 1 1/4" x 16 GA. STRAP W/ 11-10d COMM. NAILS EA. END @ EA. PLATE (STRAP NOT REQ'D FOR SILL PLATE) NOTCHES 6'-0" O.C. MIN. NOTCHES 6'-0" O.C. MIN. NOTCHES 6'-0" O.C. MIN. 1 1/4" Ø MAX. BORED HOLE 2" Ø MAX. BORED HOLE 3" Ø MAX. BORED HOLE TYPICAL BORING & NOTCHING AT SHEAR WALL PLATE DETAIL TYPICAL FLOOR & ROOF JOIST BORING & NOTCHING DETAIL 13 SPAN 13 SPAN 13 SPAN JOIST SPAN BETWEEN CL. OF BEARING WALLS "X " "Y " D= D E P T H "X " 2" M I N . 2" M I N . BORED HOLE SEE SCHEDULE NON-BEARING WALL 16" MIN. BETWEEN HOLE &/OR NOTCH NOTCH & HOLES PERMITTED ALLOWED HOLE & NOTCH FLOOR JOIST SIZE OF JOIST "X" (MAX.) NOTCH AT BEARING D/4 "Y" (MAX.) NOTCH DEPTH AS ALLOWED D/6 MAX. SIZE HOLE D/3 2X6 1 3 8"29 32"1 13 16" Ø 2X8 1 13 16"1 7 32"2 7 16" Ø 2X10 2 5 16"1 17 32"3 116" Ø 2X12 2 13 16"1 7 8"3 3 4" Ø 2X14 3 14"2 18"4 3 8" Ø NOTE: -THE ABOVE DETAIL APPLIES AT BEARING & NON- BEARING STUD WALLS -USE 2-2x CRIPPLES WHERE SPAN EXCEEDS 6'-0" 10 ' - 0 " M A X . 10 ' - 0 " M A X . 48"LAP 10-16d NAILS MIN. BETWEEN SPLICES UNLESS SHOWN OTHERWISE ON THE PLANS 2-16d NAILS @16"O.C. 3-16d NAILS 16d NAILS @16"O.C. DOUBLE STUDS EA. SIDE OF OPENING MORE THAN 4'-0" IN WIDTH PLYWOOD EDGE NAIL'G FULL HT. @PLYWOOD SHEAR WALLS 3-16d NAILS 2-10d NAILS SILL BOLTING (TYPICAL) 2-8d NAILS EACH SIDEHDR BEAM PER PLAN 2x CRIPPLE 16d NAILS @12" O.C. 1-2x PL. 4'-0" MAX. 2-2x PL. OVER 4'-0" TYPICAL STUD WALL FRAMING DETAIL "Y " S-4.1 TY P . F R A M I N G D E T A I L S SHEET NUMBER CONSULTANT The above drawings, specifications, ideas, and arrangements represented thereby are and shall remain property of GxG CO-op Design and no part thereof shall be copied, disclosed to others or used in connection with any other project other than the specific project for which they have been prepared and developed, without the written consent of GxG CO-op Design. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and this office must be notified of any variations from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceding with fabrication.2021 DATE SCALE DRAWN JOB no. REVISIONS INDICATED FEB. 29, 2024 13637 RUTHER AVE. UNIT R SOUTH GATE, CA 90280 TELEPHONE: 310 749.7536 E-MAIL: LOOKING4GIO@GMAIL.COM GIOVANNI QUINTERO 1401 S. Lowell Street, Santa Ana, CA 92707 NEW PATIO COVER 1401 S Lowell St 11/13/2024 STRUCTURAL DESIGN CALCULATIONS NEW PATIO COVER Giovanni Quintero 13637 Ruther Ave. Unit R South Gate, CA 90280 Telephone: 310 749 7536 e-mail: looking4gio@gmail.com 1401 S. Lowell Street, Santa Ana, CA 92707. February 29, 2024 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R South Gate, CA 90280 Telephone: 310 749 7536 e-mail: looking4gio@gmail.com Project: Lowell Patio Engineer: A.H. Date: 02/29/2024 CONTENTS APPENDIX I ................................................................................................................................................................. 3 Seismic & Wind Calculations ................................................................................................................................ 3 APPENDIX II .............................................................................................................................................................. 12 Beam Calculations ................................................................................................................................................ 12 APPENDIX III ............................................................................................................................................................ 20 Posts Verifications ................................................................................................................................................ 20 APPENDIX IV ............................................................................................................................................................ 22 Foundation Calculations ...................................................................................................................................... 22 Page 2 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R South Gate, CA 90280 Telephone: 310 749 7536 e-mail: looking4gio@gmail.com Project: Lowell Patio Engineer: A.H. Date: 02/29/2024 APPENDIX I Seismic & Wind Calculations Page 3 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R Project: Lowell Patio South Gate, CA 90280 Engineer: A.H. Telephone: 310 749.7536 Date : 02/29/2024 e-mail: looking4gio@gmail.com 1 1)COVER PATIO 2 2x8 R.R @ 16" O.C.2.6 3 Asphalt Shingle 4.0 4 1/2" OSB Sheathing 1.5 5 Misc.0.9 6 Total 9.0 Lb/Sq.ft 7 2)CEILING DL 8 2x10 C.J @ 16" O.C.3.3 9 5/8" Thick Drywall 3.2 10 Misc.0.5 11 Total 7.0 Lb/Sq.ft 12 13 14 15 16 17 18 19 20 21 22 23 24 28 29 30 31 32 COVER PATIO = 20.0 lb/sq.ft 5 6 7 8 LIVE LOADS LOAD ESTIMATES DEAD LOADS Page 4 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R Project: Lowell Patio South Gate, CA 90280 Engineer: A.H. Telephone: 310 749.7536 Date : 02/28/2024 e-mail: looking4gio@gmail.com ROOF DL =9.00 Lb/Sq.ft CEILING DL =7.00 Lb/Sq.ft AREA DL (PSF) Roof 555 9.0 4999 Lbs Ceiling 463 7.0 3239 Lbs 555 Sq.ft. 8238 Lbs SEISMIC LOADS - - TOTAL ROOF DIAPHRAGM AREA -- COVER PATIO TRELLIS LEVEL DEAD WEIGHT Total Length (Ft.) H (Ft.)WEIGHT [Lbs] Page 5 of 26 1401 S Lowell St 11/13/2024 Page 6 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R Project: Lowell Patio South Gate, CA 90280 Engineer: A.H. Telephone: 310 749.7536 Date : 02/28/2024 e-mail: looking4gio@gmail.com INPUT DATA Typical floor height h =8.4 Ft. Typical floor weight wx =8,238 Lbs Number of floors n =1 Importance factor (ASCE 11.5.1) I =1.00 (IBC Tab.1604.5) Building location Site class (A, B, C, D, E, F)D (If no soil report, use D) The coefficient (ASCE Tab 12.8-2)Ct =0.02 The coefficient(ASCE Tab. 12.2.1) R =1.50 Seismic design category D Latitude:33.73 Longitude:-117.88 SS =128.90 %g, Sms 1.547 g , Fa =1.200 S1 =46.10 %g, Sm1 0.599 g , Fv =1.300 SDS =1.031 g ,SD1 =0.400 g hn =8 Ft k = 1.00 , (ASCE 12.8.3, pg 130) x = 0.75 , (ASCE Tab 12.8-2)Ta = Ct (hn)x =0.10 Sec, (ASCE 12.8.2.1) W = 8,238 Lbs Swxhk =69,282 DESIGN SUMMARY Cs = 0.69 V = 5,662 Lbs E = 5662.3 Lbs. * ρ /1.4 =5,153 Lbs VERTICAL DISTRIBUTION OF LATERAL FORCES Level Level Floor to Height Weight No. Name floor Height hx wx wxhx k Cvx Fx Vx Ft. Ft. Lbs Lbs Lbs 1 Roof 8.41 8.4 8238 69,282 1.00 5,153 5,153 DIAPHRAGM FORCES Level SFi SW i Fpx Redundancy factor (ASCE 12.3.4) Name Lbs Lbs Lbs ρ =1.3 Roof 5,153 8,238 3,397 Lateral force V = Cs*W ASD E=V*ρ/1.4 COVER PATIO SEISMIC ANALYSIS BASED ON IBC 2021 (Equivalent Lateral-Force Procedure, ASCE 7-16 12.8) 1401 S. Lowell St., Santa Ana, CA 92707 Page 7 of 26 1401 S Lowell St 11/13/2024 PROJECT : PAGE : CLIENT : DESIGN BY : JOB NO. : DATE : REVIEW BY : INPUT DATA Exposure category (B, C or D)=B Importance factor, 1.0 only, (Table 1.5-2)Iw = 1.00 Basic wind speed (ASCE 7-16 26.5.1) Topographic factor (26.8 & Table 26.8-1)Kzt = 1 Flat Height of ridge H = 11.5 ft Roof slope 4 : 12 Roof length L = 33 ft Roof horizontal projected width B = 15.33 ft Effective area of component / cladding A = 50 2 DESIGN SUMMARY 1. Main Wind-Force Resisting System Max horizontal force / base shear from roof = 0.98 kips + 0.97 kips (eave & columns increasing) S 1.95 kips Max vertical download force = 1.03 kips Max vertical uplift force = 6.99 kips Max bending moment, at centroid of base, from roof = 30.29 ft-kips + 6.58 ft-kips (eave & columns increasing) S 36.87 ft-kips 2. Component and Cladding Elements Max inward pressure =21 psf Max net outward pressure =27 psf ANALYSIS Velocity pressure qh = 0.00256 Kh Kzt Kd V2 =14.04 psf where: qh = velocity pressure at mean roof height, h. (Eq. 28.3-1 page 298 & Eq. 30.3-1 page 316) Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 28.3-1, pg 299)= 0.70 Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250)= 0.85 h = height of mean roof =10.22 ft Main Wind-Force Resisting System p = qh G CN F = p Af where: G = gust effect factor. (Sec. 26.9)=0.85 q =18.43 degree <45 deg. [Satisfactory] Af = roof actual area.= 204.7 ft2, front / back = 61.9 ft2, each side CN = net force coefficients. (Fig. 27.4-5, page 268 & Fig. 27.4-7, page 270, and CNS for two sides of sloped roof.) Check Fig.27.4 limitation h / L = 0.31 within [0.25 , 1.0][Satisfactory] h / B = 0.67 within [0.25 , 1.0][Satisfactory] CNW CNL CNS CNW CNL CNS CNW CNL CNS CNW CNL CNS 1.10 -0.17 -0.80 0.01 -0.96 0.80 -1.20 -1.09 -1.20 -0.69 -1.65 0.50 p 13.13 -2.04 -9.55 0.10 -11.49 9.55 -14.32 -13.03 -14.32 -8.25 -19.64 5.97 F 2.69 -0.42 -0.59 0.02 -2.35 0.59 -2.93 -2.67 -0.89 -1.69 -4.02 0.37 CASE A CASE B CASE A CASE B Horizontal force / base shear H (kips) 0.98 0.75 -0.08 0.74 Vertical download force V (kips) 1.03 0.00 0.00 0.00 Vertical uplift force V (kips) 0.00 1.09 6.99 4.72 Bending moment at centroid of base M (ft-kips) 0.8 16.9 21.6 30.3 CLEAR FLOW OBSTRUCTED Wind Analysis for Shade Open Structure Based on ASCE 7-2016 CLEAR WIND FLOW OBSTRUCTED WIND FLOW CASE A CASE B CASE A CASE B Page 8 of 26 1401 S Lowell St 11/13/2024 (cont'd) DETERMINE HORIZONTAL WIND LOAD OF COLUMNS AND EAVE Fcol & eave = pcol & eave Acol & eave =0.97 kips where: pcol & eave = horizontal wind pressure =14.04 psf Acol & eave = horizontal projected area of columns and eave = 68.8 ft2 Mcol & eave =6.6 ft-kips Component and Cladding Elements of Roof (Sec. 30.8.2) p = qh G CN where:CN = net force coefficients. (Fig. 30.8-2, page 252) a = Max[ Min( 0.1L , 0.1B , 0.4h ) , 0.04L , 0.04B , 3ft ] , (Fig. 30.8-2, footnote 6)=3.0 ft For effective area, 50 sq.ft. as given CN 1.76 -1.62 1.76 -1.62 1.15 -1.05 0.80 -2.25 0.80 -2.25 0.50 -1.51 p (psf)21.00 -19.36 21.00 -19.36 13.67 -12.58 9.49 -26.87 9.49 -26.87 5.97 -18.00 CLEAR WIND FLOW OBSTRUCTED WIND FLOW ZONE 3 ZONE 2 ZONE 1 ZONE 3 ZONE 2 ZONE 1 q q  Page 9 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R Project: Lowell Patio South Gate, CA 90280 Engineer: A.H. Telephone: 310 749.7536 Date : 02/28/2024 e-mail: looking4gio@gmail.com Design Lateral Load = F =5153 Lbs. H1 =2.62 Ft. Number of posts =8 Posts H =8.00 Ft. Load per post = fp =644 Lbs./post α =45° ΣMo = - A * 2.62ft. + 644lbs. * 8ft. = 0 B = A = 1966 Lbs. P = A * √2 = 2781 Lbs. Use =4 5/8" ø LAG SCREWS Withdrawal value (ω) =305 Lbs/in, (Per NDS 2018 Table 12.2A) Embedment ( p ω ) =4 In. Lateral Desig Value ( Z ) =420 Lbs, (Per NDS 2018 Table 12.J) W = ω*ρω = 305 Lbs./in x 4 in =1220 Lbs. CD =1.60 (11.3.2, NDS2018) CM =1.00 (11.3.3, NDS2018)W' = 1464 Lbs. Ct =1.00 (11.3.4, NDS2018) Ceg =0.75 (12.5.2, NDS2018) Ctn =-(12.5.2, NDS2018) Cg =1.00 (11.3.6A, NDS2018) CΔ =1.00 (11.3.3, NDS2018)Z' = 504 Lbs. Cdi =-(11.3.2, NDS2018) 750 Lbs. 2999 Lbs. 2999 Lbs. > 2781 Lbs. NDS 2018 (ASD) Table 11.3.1 Z' = Z *CD * CM* Ct * Cg * CΔ * Ceg * Cdi * Ctn OK KNEE BRACE LATERAL LOAD DESIGN - ASD W' = W *CD * CM* Ct * Ceg * Ctn NDS 2018 (ASD) Table 11.3.1 P B A α H1P αA B F H fp fp 𝑍=𝑍∗𝑊′ 𝑍∗𝑠𝑖𝑛𝛼+𝑊∗𝑐𝑜𝑠𝛼= 𝑁∗𝑍= Page 10 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R Project: Lowell Patio South Gate, CA 90280 Engineer: A.H. Telephone: 310 749.7536 Date : 02/28/2024 e-mail: looking4gio@gmail.com Use:1 3/4" ø BOLTS Lateral Design Value ( Z ) =1750 Lbs, (Per NDS 2018 Table 12.F) Z' = 2100 Lbs. 2100 Lbs. 2100 Lbs. > 1966 Lbs.OK KNEE BRACE LATERAL LOAD DESIGN - ASD SHEAR CONNECTION AT CENTER POST f 𝑁∗𝑍= Page 11 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R South Gate, CA 90280 Telephone: 310 749 7536 e-mail: looking4gio@gmail.com Project: Lowell Patio Engineer: A.H. Date: 02/29/2024 APPENDIX II Beam Calculations Page 12 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R Project: Lowell Patio South Gate, CA 90280 Engineer: A.H. Telephone: 310 749.7536 Date : 02/29/2024 e-mail: looking4gio@gmail.com 1 1)ROOF 2 2x8 R.R @ 16" O.C.2.6 3 Asphalt Shingle 4.0 4 1/2" OSB Sheathing 1.5 5 Misc. 0.9 6 Total 9.0 Lb/Sq.ft 7 2)CEILING DL 8 2x10 C.J @ 16" O.C.3.3 9 5/8" Thick Drywall 3.2 10 Misc.0.5 11 Total 7.0 Lb/Sq.ft 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 ROOF = 20.0 lb/sq.ft 5 CEILING =10.0 lb/sq.ft 6 7 8 LIVE LOADS LOAD ESTIMATES DEAD LOADS Page 13 of 26 1401 S Lowell St 11/13/2024 Multiple Simple Beam LIC# : KW-06018780, Build:20.23.08.30 GED CONSULTANTS, INC. (c) ENERCALC INC 1983-2023 Project File: Lowell Patio.ec6 Project Title: Engineer: Project ID: Project Descr: Joist VerificationDescription : BEAM Size :2x8, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2021, ASCE 7-16 Douglas Fir-Larch No.2 875.0 875.0 600.0 625.0 1,300.0 470.0 170.0 425.0 31.210 Eminbend - xx ksi Wood Species : Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf R.R. Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.010, Lr = 0.020 k/ft, Trib= 1.0 ft .Design Summary Max fb/Fb Ratio =0.211 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 3.710 inft 13.91 psi Fb : Allowable : 963.73 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 212.50 psi fb : Actual : Max fv/FvRatio =0.065 : 1 6.826 ft 203.35 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.022 in Transient Upward 0.000 in Total Downward 0.036 in Total Upward 0.000 in 0.05 0.07 0.05 0.07 Ratio 4020 2485Ratio LC: Lr Only LC: +D+Lr LC: LC: BEAM Size :2x10, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2021, ASCE 7-16 Douglas Fir-Larch No.2 875.0 875.0 600.0 625.0 1,300.0 470.0 170.0 425.0 31.210 Eminbend - xx ksi Wood Species : Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf C.J. Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.0070, Lr = 0.010 k/ft, Trib= 1.0 ft .Design Summary Max fb/Fb Ratio =0.747 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 7.400 inft 14.41 psi Fb : Allowable : 411.13 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 212.50 psi fb : Actual : Max fv/FvRatio =0.068 : 1 14.060 ft 307.31 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.084 in Transient Upward 0.000 in Total Downward 0.169 in Total Upward 0.000 in 0.07 0.07 0.07 0.07 Ratio 2104 1051Ratio LC: Lr Only LC: +D+Lr LC: LC: Page 14 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R Project: Lowell Patio South Gate, CA 90280 Engineer: A.H. Telephone: 310 749.7536 Date : 02/28/2024 e-mail: looking4gio@gmail.com Use: Units = ft ROOF DL1 = 9psf *7ft = 66.78 Lbs/ft Lr1 = 20psf *7.42ft = 148.4 Lbs/ft 1 RBM 101 RIDGE BEAM 4x12 D.F. #2 D1 10.8 21.6 32.432.432.432.432.432.432.432.432.432.4 D1 7.4 X Y Z Page 15 of 26 1401 S Lowell St 11/13/2024 Wood Beam LIC# : KW-06018780, Build:20.23.08.30 GED CONSULTANTS, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:RBM 101 Project File: Lowell Patio.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 875 875 600 625 1300 470 170 425 31.21 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Loads on all spans... Uniform Load on ALL spans : D = 0.0660, Lr = 0.1480 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.353: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 10.830ft 47.37 psi= = 1,203.13psi 4x12Section used for this span Span # where maximum occurs Location of maximum on span Span # 2= Load Combination +D+Lr = = = 212.50 psi== Section used for this span 4x12 Maximum Shear Stress Ratio 0.223 : 1 10.830 ft= = 424.24psi Maximum Deflection 44084 >=360 1897 Ratio =29319 >=240 Max Downward Transient Deflection 0.046 in 2853Ratio = >=360 Max Upward Transient Deflection -0.003 in Ratio = Max Downward Total Deflection 0.068 in Ratio = >=240 Max Upward Total Deflection -0.004 in fb: Actual F'b fv: Actual F'v Span: 3 : Lr Only Span: 2 : Lr Only Span: 3 : +D+Lr Span: 2 : +D+Lr .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 10.830 ft 1 0.164 0.104 0.90 1.100 1.001.00 1.00 0.87 142.1 866.3 0.42 153.01.00 15.91.00 1.00Length = 10.830 ft 2 0.164 0.104 0.90 1.100 1.001.00 1.00 0.87 142.1 866.3 0.42 153.01.00 15.91.00 1.00Length = 10.830 ft 3 0.164 0.104 0.90 1.100 1.001.00 1.00 0.87 142.1 866.3 0.42 153.01.00 15.91.00 1.00+D+Lr 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 10.830 ft 1 0.353 0.223 1.25 1.100 1.001.00 1.00 2.61 424.2 1,203.1 1.24 212.51.00 47.41.00 1.00Length = 10.830 ft 2 0.353 0.223 1.25 1.100 1.001.00 1.00 2.61 424.2 1,203.1 1.24 212.51.00 47.41.00 1.00Length = 10.830 ft 3 0.353 0.223 1.25 1.100 1.001.00 1.00 2.61 424.2 1,203.1 1.24 212.51.00 47.41.00 1.00+D+0.750Lr 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 Page 16 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R Project: Lowell Patio South Gate, CA 90280 Engineer: A.H. Telephone: 310 749.7536 Date : 02/28/2024 e-mail: looking4gio@gmail.com Use: Units = ft ROOF CEILING DL1 = 9psf *4ft+7psf *7.41ft = 91.16 Lbs/ft Lr1 = 20psf *4.37ft = 87.32 Lbs/ft 1 Use: Units = ft CEILING BEAM SUPP.DL Lr LL E Units DL1 = 7psf *0.66ft = 4.62 Lbs/ft RBM 101 1 320 640 0 0 [Lbs] Lr1 = 10psf *0.66ft = 6.6 Lbs/ft 1 Use: Units = ft CEILING BEAM SUPP.DL Lr LL E Units DL1 = 7psf *1.33ft = 9.31 Lbs/ft RBM 101 2 890 1760 0 0 [Lbs] Lr1 = 10psf *1.33ft = 13.3 Lbs/ft 1 DBM 103 DROP BEAM 6x10 D.F. #1 DBM 102 DROP BEAM 6x10 D.F. #2 DBM 101 DROP BEAM 6x10 D.F. #2 D1 10.810.810.810.810.810.810.810.810.810.810.810.8 D1 4.4 7.4 D1 RBM 101 7.4 14.814.814.814.814.814.814.814.814.814.814.8 D1 0.7 D1 RBM 101 7.4 14.814.814.814.814.814.814.814.814.814.814.8 D1 1.3 X Y Z X Y Z X Y Z Page 17 of 26 1401 S Lowell St 11/13/2024 Multiple Simple Beam LIC# : KW-06018780, Build:20.23.08.30 GED CONSULTANTS, INC. (c) ENERCALC INC 1983-2023 Project File: Lowell Patio.ec6 Project Title: Engineer: Project ID: Project Descr: DBM 101-102-103Description : BEAM Size :6x10, Sawn, Fully Unbraced Using Allowable Stress Design with IBC 2021 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2021, ASCE 7-16 Douglas Fir-Larch No.2 875 875 600 625 1300 470 170 425 31.21 Eminbend - xx ksi Wood Species : Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf DBM 101 Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.0910, Lr = 0.0870 k/ft, Trib= 1.0 ft .Design Summary Max fb/Fb Ratio =0.369 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 5.400 inft 25.24 psi Fb : Allowable : 1,084.57 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 212.50 psi fb : Actual : Max fv/FvRatio =0.119 : 1 10.044 ft 400.39 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.052 in Transient Upward 0.000 in Total Downward 0.114 in Total Upward 0.000 in 0.55 0.47 0.55 0.47 Ratio 2472 1136Ratio LC: Lr Only LC: +D+Lr LC: LC: BEAM Size :6x10, Sawn, Fully Unbraced Using Allowable Stress Design with IBC 2021 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2021, ASCE 7-16 Douglas Fir-Larch No.2 875 875 600 625 1300 470 170 425 31.21 Eminbend - xx ksi Wood Species : Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf DBM 102 Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.004620, Lr = 0.0060 k/ft, Trib= 1.0 ft 1Point: D = 0.320, Lr = 0.640 k @ 7.40 ft .Design Summary Max fb/Fb Ratio =0.557 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 7.400 inft 17.94 psi Fb : Allowable : 1,080.53 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 212.50 psi fb : Actual : Max fv/FvRatio =0.084 : 1 14.011 ft 602.38 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.160 in Transient Upward 0.000 in Total Downward 0.267 in Total Upward 0.000 in 0.28 0.36 0.28 0.36 Ratio 1112 665Ratio LC: Lr Only LC: +D+Lr LC: LC: Page 18 of 26 1401 S Lowell St 11/13/2024 Multiple Simple Beam LIC# : KW-06018780, Build:20.23.08.30 GED CONSULTANTS, INC. (c) ENERCALC INC 1983-2023 Project File: Lowell Patio.ec6 Project Title: Engineer: Project ID: Project Descr: BEAM Size :6x10, Sawn, Fully Unbraced Using Allowable Stress Design with IBC 2021 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2021, ASCE 7-16 Douglas Fir-Larch No.1 1350 1350 925 625 1600 580 170 675 31.21 Eminbend - xx ksi Wood Species : Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf DBM 103 Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.009310, Lr = 0.0130 k/ft, Trib= 1.0 ft 1Point: D = 0.890, Lr = 1.760 k @ 7.40 ft .Design Summary Max fb/Fb Ratio =0.937 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 7.400 inft 44.42 psi Fb : Allowable : 1,660.58 psi Right Support Fv : Allowable : Span # 1 Load Comb : +D+Lr 212.50 psi fb : Actual : Max fv/FvRatio =0.209 : 1 14.011 ft 1,555.81 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.351 in Transient Upward 0.000 in Total Downward 0.552 in Total Upward 0.000 in 0.60 0.980.60 0.98 Ratio 506 321Ratio LC: Lr Only LC: +D+Lr LC: LC: Page 19 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R South Gate, CA 90280 Telephone: 310 749 7536 e-mail: looking4gio@gmail.com Project: Lowell Patio Engineer: A.H. Date: 02/29/2024 APPENDIX III Posts Verifications Page 20 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R Project: Lowell Patio South Gate, CA 90280 Engineer: A.H. Telephone: 310 749.7536 Date : 02/28/2024 e-mail: looking4gio@gmail.com DBM 101(1) + DBM 102(2)1660.00 N/A 8.00 6x6 35364.00 OK - DBM 101(1) + DBM 102(2)1660.00 N/A 8.00 6x6 35364.00 OK - DBM 101(1) + DBM 101(2) + DBM 103(2)3620.00 N/A 8.00 6x6 35364.00 OK - DBM 101(1) + DBM 101(2) + DBM 103(1)3620.00 N/A 8.00 6x6 35364.00 OK - DBM 101(2) + DBM 102(2)1660.00 N/A 8.00 6x6 35364.00 OK - DBM 101(2) + DBM 102(1)1660.00 N/A 8.00 6x6 35364.00 OK - POST VERIFICATION Proposed Post Alowable Axial Load [Lbs] Status ROOF LEVEL Beam or beams arriving at post Axial Load [Lbs] Width of wall Height [Ft]Observations Page 21 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R South Gate, CA 90280 Telephone: 310 749 7536 e-mail: looking4gio@gmail.com Project: Lowell Patio Engineer: A.H. Date: 02/29/2024 APPENDIX IV Foundation Calculations Page 22 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R Project: Lowell Patio South Gate, CA 90280 Engineer: A.H. Telephone: 310 749.7536 Date : 02/28/2024 e-mail: looking4gio@gmail.com SOIL BEARING CAPACITY =1500 Psf. DBM 101(1) + DBM 102(2)1660 1500 PAD NEEDED F1 DBM 101(1) + DBM 102(2)1660 1500 PAD NEEDED F1 DBM 101(1) + DBM 101(2) + DBM 103(2) 3620 1500 PAD NEEDED F1 DBM 101(1) + DBM 101(2) + DBM 103(1) 3620 1500 PAD NEEDED F1 DBM 101(2) + DBM 102(2)1660 1500 PAD NEEDED F1 DBM 101(2) + DBM 102(1)1660 1500 PAD NEEDED F1 Beam or beams arriving at pad "P" from enercalc [Lbs] H [Ft]W [Ft] L = 2H [Ft] Area A=W*L [Ft2] < Pad N° See Enercalc 0 σ = P/A [pcf] PAD REQUIREMENT Status Soil Bearing Capacit y [pcf] Page 23 of 26 1401 S Lowell St 11/13/2024 General Footing LIC# : KW-06018780, Build:20.23.08.30 GED CONSULTANTS, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:F1 Project File: Lowell Patio.ec6 Project Title: Engineer: Project ID: Project Descr: Code References Calculations per ACI 318-19, IBC 2021, ASCE 7-16 Load Combinations Used : IBC 2021 General Information Material Properties Soil Design Values 1.50 Analysis Settings 100.0 ksi No ksfAllowable Soil Bearing = = 2.50 60.0 3,122.0 145.0 = 0.250Flexure = 0.90 Shear = Values 0.00180 Soil Passive Resistance (for Sliding) 1.0 = Increases based on footing plan dimension Add Pedestal Wt for Soil Pressure No: Use Pedestal wt for stability, mom & shear No: Allowable pressure increase per foot of depth = ksf when max. length or width is greater than = ft : = Add Ftg Wt for Soil Pressure Yes Yes:Use ftg wt for stability, moments & shears when footing base is below ft pcf Increase Bearing By Footing Weight = pcf Min. Overturning Safety Factor = : 1 Increases based on footing Depth0.750 = Soil/Concrete Friction Coeff. Ec : Concrete Elastic Modulus = =Footing base depth below soil surface ft =Allow press. increase per foot of depth ksf = : 11.0Min. Sliding Safety Factor = = Concrete Density = Min Allow % Temp Reinf. ksif'c : Concrete 28 day strength fy : Rebar Yield ksi Min Steel % Bending Reinf. Soil Density =110.0 pcf # Dimensions Width parallel to X-X Axis 2.250 ft Length parallel to Z-Z Axis = 2.250 ft =Pedestal dimensions... px : parallel to X-X Axis in pz : parallel to Z-Z Axis in Height = = in Footing Thickness = 24.0 in= Rebar Centerline to Edge of Concrete... = inat Bottom of footing 3.0 Reinforcing # Bars parallel to X-X Axis Reinforcing Bar Size = 5 Number of Bars = 4 Bars parallel to Z-Z Axis Reinforcing Bar Size = 5 Number of Bars = 4 Bandwidth Distribution Check (ACI 15.4.4.2) Direction Requiring Closer Separation n/a # Bars required within zone n/a # Bars required on each side of zone n/a Applied Loads 1.70 1.920 D Lr ksf L S P : Column Load OB : Overburden = k W E M-zz V-x = = k0.6440 V-z k M-xx = k-ft= k-ft H = Page 24 of 26 1401 S Lowell St 11/13/2024 General Footing LIC# : KW-06018780, Build:20.23.08.30 GED CONSULTANTS, INC. (c) ENERCALC INC 1983-2023 DESCRIPTION:F1 Project File: Lowell Patio.ec6 Project Title: Engineer: Project ID: Project Descr: PASS 1.054 Sliding - X-X 0.4508 k 0.4752 k +0.60D+0.70E PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding DESIGN SUMMARY Design OK Governing Load CombinationMin. Ratio Item Applied Capacity PASS 0.7307 Soil Bearing 1.096 ksf 1.50 ksf +D+0.70E about Z-Z axis PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning PASS 2.372 Overturning - Z-Z 0.9016 k-ft 2.138 k-ft +0.60D+0.70E PASS n/a Uplift 0.0 k 0.0 k No Uplift PASS 0.01266 Z Flexure (+X) 0.6390 k-ft/ft 50.472 k-ft/ft +1.20D+1.60Lr PASS 0.01266 Z Flexure (-X) 0.6390 k-ft/ft 50.472 k-ft/ft +1.20D+1.60Lr PASS 0.01266 X Flexure (+Z)0.6390 k-ft/ft 50.472 k-ft/ft +1.20D+1.60Lr PASS 0.01266 X Flexure (-Z)0.6390 k-ft/ft 50.472 k-ft/ft +1.20D+1.60Lr PASS n/a 1-way Shear (+X) 0.0 psi 75.0 psi n/a PASS 0.0 1-way Shear (-X) 0.0 psi 0.0 psi n/a PASS n/a 1-way Shear (+Z) 0.0 psi 75.0 psi n/a PASS n/a 1-way Shear (-Z) 0.0 psi 75.0 psi n/a PASS n/a 2-way Punching 1.135 psi 75.0 psi +1.20D+1.60Lr Top reinforcing mat required (see 'Bending' tab). Hand check required for anchor pullout. Detailed Results Rotation Axis &ZeccXecc Actual Soil Bearing Stress @ Location Actual / Allow Soil Bearing (in)Gross Allowable Bottom, -Z Top, +Z Left, -X Right, +X RatioLoad Combination... X-X, D Only 1.50 n/a0.6258 0.6258 n/a 0.4170.0n/a X-X, +D+Lr 1.50 n/a1.005 1.005 n/a 0.6700.0n/a X-X, +D+0.750Lr 1.50 n/a0.9102 0.9102 n/a 0.6070.0n/a X-X, +D+0.70E 1.50 n/a0.6258 0.6258 n/a 0.4170.0n/a X-X, +D+0.5250E 1.50 n/a0.6258 0.6258 n/a 0.4170.0n/a X-X, +0.60D 1.50 n/a0.3755 0.3755 n/a 0.2500.0n/a X-X, +0.60D+0.70E 1.50 n/a0.3755 0.3755 n/a 0.2500.0n/a Z-Z, D Only 1.50 0.6258n/a n/a 0.6258 0.417n/a0.0 Z-Z, +D+Lr 1.50 1.005n/a n/a 1.005 0.670n/a0.0 Z-Z, +D+0.750Lr 1.50 0.9102n/a n/a 0.9102 0.607n/a0.0 Z-Z, +D+0.70E 1.50 0.1556n/a n/a 1.096 0.731n/a3.415 Z-Z, +D+0.5250E 1.50 0.2732n/a n/a 0.9784 0.652n/a2.561 Z-Z, +0.60D 1.50 0.3755n/a n/a 0.3755 0.250n/a0.0 Z-Z, +0.60D+0.70E 1.50 0.0n/a n/a 0.8606 0.574n/a5.692 Rotation Axis & Overturning Stability Load Combination... StatusOverturning Moment Resisting Moment Stability Ratio X-X, D Only None 0.0 k-ft Infinity OK X-X, +D+Lr None 0.0 k-ft Infinity OK X-X, +D+0.750Lr None 0.0 k-ft Infinity OK X-X, +D+0.70E None 0.0 k-ft Infinity OK X-X, +D+0.5250E None 0.0 k-ft Infinity OK X-X, +0.60D None 0.0 k-ft Infinity OK X-X, +0.60D+0.70E None 0.0 k-ft Infinity OK Z-Z, D Only None 0.0 k-ft Infinity OK Z-Z, +D+Lr None 0.0 k-ft Infinity OK Z-Z, +D+0.750Lr None 0.0 k-ft Infinity OK Z-Z, +D+0.70E 0.9016 k-ft 3.564 k-ft 3.953 OK Z-Z, +D+0.5250E 0.6762 k-ft 3.564 k-ft 5.271 OK Z-Z, +0.60D None 0.0 k-ft Infinity OK Z-Z, +0.60D+0.70E 0.9016 k-ft 2.138 k-ft 2.372 OK Page 25 of 26 1401 S Lowell St 11/13/2024 Giovanni Quintero 13637 Ruther Ave. Unit R Project: Lowell Patio South Gate, CA 90280 Engineer: A.H. Telephone: 310 749.7536 Date : 02/28/2024 e-mail: looking4gio@gmail.com Weight [Lbs] Lenght 2.25 Depth 2.00 2050 1660 3710 Foundation Weight = 3710 >875 4.24 >1.25 Safety Factor OK 875 Uplift Verification: = Seismic Uplift Seismic Uplift: *Per Wind Analysis Uplift [Lbs] 2050 TOTAL WEIGHT Dead Load Column Total Weight Foundation Column UPLIFT VERIFICATION Weight Calculation: Concrete Pad Dimensions [ft] Concrete Density [Lbs/ft3] 145 Page 26 of 26 1401 S Lowell St 11/13/2024